RAMP DCIM Data Center Infrastructure Management Software
|
|
- Bryce Bennett
- 5 years ago
- Views:
Transcription
1 RAMP DCIM Data Center Infrastructure Management Software RFP TEMPLATE TUANGRU.COM
2 DCIM RFP TEMPLATE Dear Sir or Madam, Your company has been invited to submit your company s qualifications to participate in the bidding process for a Data Center Infrastructure Management (DCIM) solution for [company]. The goal of this project will be to provide a DCIM tool for use within critical spaces. The required deliverables for the project are outlined in the pages following this cover letter. The scope of the project as well as the schedule of the RFP can be found enclosed. We suggest closely reviewing the entire RFP. As part of your submission, please include a high level schedule for each phase of the project. This schedule is to be based on your experience with similar projects. Additionally, include expected high level budgets based on project description. Both schedules and budgets will be used for reference, but final time line and costs will be negotiated once a firm is selected. We wish you the best in preparing and submitting your qualifications. Please feel free to contact me at [phone number] or [ address] if I can provide any clarifications. Sincerely, [name] 1
3 CONTENTS 1. Response Instruction Supplemental Materials Inspections Schedule Pricing Description of Data Center(s) Scope of Services System Overview Floor Plan Layout Rack Elevation View Inventory Workflow Processes Power Monitoring Cooling and Environmental Monitoring Alarm Notifications Equipment Location Planning Equipment Location Planning IT Device Management Infrastructure Device Management Reporting Virtualization Integration Security API
4 1. Response Instruction Each vendor s response must be no more than [#] pages. Time on site can be scheduled if a site visit is required to gather information necessary to provide a cost. 2. Supplemental Materials Vendors are responsible for including all pertinent services in the qualification package. Data sheets, typical warranties, specification information, completed forms requested as part of the submission, and any other information which may affect the evaluation and contract award should be included. Materials such as legal documents and contractual agreements which the vendor wishes to include as a condition of the bid must also be in the returned bid package. Failure to include all necessary and proper supplemental materials may be cause to reject the entire bid. As these documents are not part of the proposal, they are not subject to the [#] page limit. 3. Inspections [Company] reserves the right to interview any references and/or make arrangements to visit any vendor s referenced site to verify vendor s qualifications to meet the demands of this project. If a vendor cannot furnish references or make arrangements for a site visit, or fails to satisfactorily show an ability to perform, the vendor s bid can be rejected as inadequate. 4. Schedule RFP submission open Deadline for submission of questions, 5 PM EST RFP submission closed, 5 PM EST Interview shortlist firms Announce selected firm Project start Project completion 5. Pricing All costs shall be provided in a table showing itemized costs and a total cost. [Company] may choose to purchase one or more separate modules if the DCIM solution contains multiple modules. All recurring maintenance and licensing cost information shall be provided in a separate table. These costs should be listed on a yearly basis. Include pricing to show cost to increase capacity to support additional equipment. 3
5 6. Description of Data Center(s) [A description of the data center(s) should be given including, but not limited to, location, square footage, facility equipment and capacities, IT equipment count, virtualization percent, number of racks, current monitoring systems in place, and anticipated growth. List any other systems with which the DCIM solution should integrate, including BMS, CMDB, trouble ticketing, change management, and external databases.] 7. Scope of Services 7.1. System Overview The DCIM shall be a web-based system that is accessed through a standard webbrowsing tool such as Internet Explorer, Chrome, or Firefox The DCIM should be able to run on a physical or virtualized server The DCIM must be able to maintain inventory and asset management within the data center and provide visualization of the assets in floor layout, rack elevation, and individual asset views The DCIM must be able to monitor virtual machines and physical servers, including blade servers and blade chassis The DCIM must be able to monitor network equipment, including switches and routers The DCIM must be able to monitor power at the device, rack PDU, rack, and facility levels The DCIM must be able to monitor cooling equipment in the data center The DCIM must be able to monitor environmental conditions in the data center The DCIM must support auto-discovery of detailed asset information for both IT and Facility equipment The DCIM must keep a log of all changes within the data center. Where possible, this change management should be automated The DCIM must be able to manage tasks and workflows (linked set of tasks) The DCIM must be able to create reports in PDF, Microsoft Word, or Excel spreadsheet formats. The DCIM should provide the ability to create custom reports without requiring an external report creation tool. All reports, including custom reports, should be able to be automatically created and distributed via The DCIM should display energy efficiency information such as PUE, DCiE, and CADE for a location, as well as showing capacity information for space, power, network, and cooling Floor Plan Layout The DCIM tool shall display inventory data within the data center physical layout. Location-based drill-down views shall provide a structured overview of data center locations from a global to local view down to single assets. The DCIM tool shall support a multi-layer overhead graphical floor layout which allow the user to view the equipment in the room by status, temperature, power, and other attributes. The DCIM shall have the ability to add locations and rooms of different types to the data center model to represent the physical enterprise infrastructure. The DCIM shall provide the ability to modify location layouts from within the DCIM tool. 4
6 7.3. Rack Elevation View The DCIM tool shall visually represent the physical layout of IT equipment in a rack. Both front and rear views of the rack shall be supported. The rack view shall show IT equipment as well as rack PDUs, power connections, communication connections, shelves, blanking panels, and available space. Multiple layers should be supported to show temperature, status, and power of the equipment within the rack. Zero U equipment shall be supported. The rack elevation view shall support dragging and dropping of equipment within the rack, as well as the ability to drag new equipment into the rack. Power and network connections should support drag and drop to easily set power and communication connections. The rack elevation view shall also show the power and environmental conditions at the rack. This data should be displayed in a graphical view for the past day, week, or month Inventory The DCIM tool shall provide a model database that contains both floor and rack mounted data center equipment with detailed information such as weight, dimensions, typical power usage, images, and other device-specific information (such as number and type of outlets for rack PDUs). The DCIM shall support dynamic searching by name, IP address, manufacturer, model, location, serial number, device type, or any other applicable fields, including user-defined fields. The DCIM should support searching by condition, such as rack PDUs with more than a certain percent load, or servers running a selected operating system, and so on. Users should be able to select the fields they want to view, the order of the fields, and any other selection criteria. The DCIM should be able to create a custom report for any search and be able to save the report for later use and to schedule the report for automatic distribution Workflow Processes The DCIM tool shall provide the ability to create processes to organize moves, adds, and changes through an automated work flow system. All tasks and workflows shall provide an audit trail of all activity. Users should be able to create their own custom processes Power Monitoring The DCIM tool shall display and report measured power load data for all infrastructure equipment, including, but not limited to, transfer switches, generators, circuit breakers, UPSs, PDUs, and rack PDUs. The DCIM will detect configuration issues regarding data center power configuration and provide recommended actions. The DCIM will perform failover calculations on an ongoing basis to determine the impact of equipment in the power chain becoming unavailable. For example, the DCIM tool will evaluate the impact of a rack PDU becoming unavailable and the impact to other rack PDUs due to equipment failing over. The DCIM will warn of conditions where IT equipment will no longer have sufficient power resources. The DCIM tool shall display the power chain for the data center, highlighting single points of failure and current power usage and capacity for each power device. 5
7 7.7. Cooling and Environmental Monitoring The DCIM tool shall display and report measured cooling load data for all infrastructure equipment, including, but no limited to, CRACs, coolers, chillers, pumps, and fans. The DCIM shall be able to determine the capacity and impact of failed cooling systems. The DCIM tool shall be able to provide inlet and exhaust temperatures at the rack by monitoring server inlet temperatures, rack PDU sensors, wireless sensors, environmental monitoring equipment, and any other available sensors in the rack. The temperature data shall be displayed visually in the floor layout. The DCIM will be able to use agentless data gathering methods to poll temperature sensors from IT equipment, including non-intel devices Alarm Notifications The DCIM tool shall be capable of triggering alerts based on criticality (critical, warning, information, unreachable). The state of all current alarms shall be available in a dashboard in the DCIM tool. The user shall have the ability to select a device in an alarm state and display the specific nature of the alarm. The DCIM shall contain an alert history for all devices and alerts, which shall be sortable by date range, location, and severity of alert. The user shall have the ability to configure notification, including the severity of the alarm, the format of the information sent in the alert, the method of transmitting the alert, and the alert recipients. The DCIM tool shall be capable of sending alerts based on manual or automatically detected changes in the data center. Automatically detected changes include, but are not limited to, network cabling changes, software installed or removed from servers, firmware changes to infrastructure equipment, operating system changes to servers, and hardware changes to IT or infrastructure equipment. The DCIM tool shall be capable of sending alerts and change messages to a valid account or to a mobile device and send SNMP traps to a network management system. Administrators shall also be configure the DCIM to use a command procedure or executable file to transmit alarms in other formats such as SMS messaging, sending messages to BMC Remedy or LANDESK, and so on Equipment Location Planning The DCIM tool shall be capable of specifying potential locations for rack-based IT equipment based on the availability and requirements of physical infrastructure capacity such as space, cooling, network, and power capacity as well as other user defined requirements. The DCIM tool shall be capable of reserving space for new equipment and predicting the impact of the added equipment on power throughout the power chain Equipment Location Planning The DCIM tool shall model the configured network connections and allow a user to manually configure physical network routes between devices. The DCIM tool shall be capable of determining the end to end network connection between devices and network equipment and shall be capable of detecting changes to the end to end connection. The DCIM tool shall display a network map for the data center. 6
8 7.11. IT Device Management The DCIM tool shall display and report measured power load data for all IT equipment where available. The DCIM will utilize agentless monitoring to gather data for IT equipment, including non-intel devices. If power data is not supplied by the IT equipment, the DCIM tool shall calculate the power based on known power information such as rack PDU outlet or total power data and typical power usage for the IT equipment. The DCIM tool will collect other sensor values from IT equipment, including, but not limited to, temperature, CPU usage, memory usage, and disk drive usage. The DCIM tool will collect asset information from IT equipment, including, but not limited to, manufacturer, model, serial number, hardware configuration, IP addresses, MAC address, installed software, firmware version, operating system, and network connections. The user interface shall allow for discovery of devices and sensors. The user shall have the ability to schedule discovery of devices with any combination of configurable settings via IP or IP range, type of device, credentials (SNMP community string or IPMI username/password, for example), time of day, and day of week or month. The DCIM shall allow newly discovered devices to be placed into a specific group or into an unassigned group. The DCIM shall automatically log discovered changes (such as hardware or software changes) for previously discovered devices and update the information for the device Infrastructure Device Management The DCIM tool will collect sensor values from infrastructure equipment, including, but not limited to, temperature, power, load, and status. The DCIM tool will collect asset information from infrastructure equipment, including, but not limited to, manufacturer, model, serial number, hardware configuration, IP addresses, MAC address, firmware version, capacity information, and network connections. The DCIM tool shall support SNMP (v1 and v3), BACnet, and Modbus TCP protocols. The DCIM tool shall be able to communicate device data and events from existing SiteScan monitoring systems Reporting All data collected over time must be stored for extracting and trending. The data collection poll cycle shall be configurable by the user, with a default of 5 minutes. Standard reports should be provided for individual devices, device type, and location. Standard report formats should include PDF, Microsoft Word, and Microsoft Excel. The user shall also have the ability to create custom reports through the DCIM tool. The custom reports shall be capable of being saved and modified as needed. All reports, including custom reports, shall be capable of being automatically run and delivered via to a group of recipients on a scheduled basis. The user shall have the ability to create reports that display graphs for multiple data points. The user shall be able to select up to 8 sensor points to be graphed and have the ability to display any combination of minimum, maximum, and average data for the selected time period. The user shall have the ability to export the data points to an Excel spreadsheet. 7
9 7.14. Virtualization Integration The DCIM software shall support integration with VMware vcenter to provide virtualization layer information. The same level of information provided at the physical server level shall be provided for virtual machines, including, but not limited to sensor values such as CPU, memory, and disk drive usage as well as asset information such as manufacturer, model, serial number, hardware resources used, IP addresses, installed software, and operating system. The DCIM tool shall provide insight into how virtual machines relate to physical servers and their location. It shall display virtual machine application names for each physical server. Users should be able to search for a virtual machine and locate its physical server Security The communication between the DCIM software and the web client shall be secured via a Secure Sockets Layer (SSL) 168 bit Triple-DES (Data Encryption Standard) encoded connection. The DCIM shall synchronize to LDAP and Active Directory. The login to the web interface shall use SSL authentication. The web launch to devices shall occur through an HTTP or HTTPS connection. The HTTP or HTTPS port shall be user configurable. The DCIM shall have no limit to the number of user accounts or groups that can be created API The DCIM software should provide a web services REST API to allow other applications to access data from the DCIM. 8
RaMP Data Center Manager. Data Center Infrastructure Management (DCIM) software
RaMP Data Center Manager Data Center Infrastructure Management (DCIM) software One solution for both IT and facilities managers As data centers become more complex, it becomes increasingly important to
More informationFeatures and Benefits: dctrack DCIM Operations Solution
1 : Asset Auto Discovery Allows for automatic recognition integration into dctrack asset management system for a newly added asset. Automatic recognition of make model of asset makes adding or changing
More informationSchneider Electric Data Center Software
Schneider Electric Data Center Software StruxureWare Operations 7.0 Software Platform End to end Data Center Infrastructure Management (DCIM) software for monitoring, control of power, cooling, security
More informationThe Most Comprehensive DCIM Solution
The Most Comprehensive DCIM Solution NetZoomDC TM is the complete, enterprise Data Center Infrastructure Management (DCIM) software which Models, Manages, Monitors and Maximizes data center assets, space,
More informationComprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of
More informationData Center Infrastructure Management (DCIM) Demystified
software is quickly becoming the core engine of data center operations. Only 5 years ago, manual spreadsheets, sometimes supplemented with Visio diagrams, were accepted as the default tools for data center
More informationOnline Help StruxureWare Data Center Expert
Online Help StruxureWare Data Center Expert Version 7.2.7 What's New in StruxureWare Data Center Expert 7.2.x Learn more about the new features available in the StruxureWare Data Center Expert 7.2.x release.
More informationCA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management
PRODUCT SHEET: CA ecometer CA ecometer Improve data center uptime and availability through better energy management agility made possible CA ecometer helps you to visualize, monitor, and better manage
More informationApplication User Guide. Version
Application User Guide Version 1.2.00 August 10, 2017 Eaton www.eaton.com/powerquality LEGAL NOTICE Copyright 2017. Eaton. All rights reserved. The contents of this document constitute valuable proprietary
More informationData Center Infrastructure Management (D.C.I.M.)
Data Center Infrastructure Management (D.C.I.M.) Garies Chong, RCDD, DCDC. BICSI Southeast Asia District Chair Managing Director of EMS Wiring Systems Pte Ltd Data Center Infrastructure Management (D.C.I.M.)
More informationFeatures and Benefits: Power IQ DCIM Monitoring Solutions
1 : Power IQ DCIM Monitoring Solutions Vendor-agnostic Management Energy Efficiency Through one web browser, monitor any device from major manufactures such as APC, Avocent, BayTech, Chatsworth, Cyber
More informationDCIM Data Center Infrastructure Management Measurement is the first step
DCIM Data Center Infrastructure Management Measurement is the first step Presented by Julius Neudorfer Sponsored by DCIM Data Center Infrastructure Management Measurement is the first step Presented by
More informationOver IP Group. Data Centre Infrastructure Management (DCIM)
Over IP Group Data Centre Infrastructure Management (DCIM) Mission To Protect the World s Network Through Innovation Let s Get Connected Over IP Group Agenda The Aim of CenterOS DCIM What is the CenterOS
More informationPower IQ DCIM Monitoring Version 5.2.2
Power IQ DCIM Monitoring Version 5.2.2 These Release Notes contain important information regarding the release of this product, so please read them carefully. We strongly recommend that you read the entire
More informationPower IQ Version 3.1
Power IQ Version 3.1 These release notes contain important information regarding the release of this product, so please read them carefully. We strongly recommend you read the entire document. Applicability:
More informationOpenManage Power Center Demo Guide for https://demos.dell.com
OpenManage Power Center Demo Guide for https://demos.dell.com Contents Introduction... 3 Lab 1 Demo Environment... 6 Lab 2 Change the default settings... 7 Lab 3 Discover the devices... 8 Lab 4 Group Creation
More informationNETZOOM PRO CLASSROOM TRAINING
2015 NetZoom Pro Classroom Training Program NETZOOM PRO CLASSROOM TRAINING By Altima Technologies, Inc. This brochure explains the training structure for NetZoom & NetZoom Pro. Altima Technologies, Inc.
More informationDCIM Data Center Infrastructure Management
DCIM Data Center Infrastructure Management Part 2 Implementation Challenges & Strategic Advantages - Predictive Analysis August 8, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Implementation
More informationPower IQ for econnect
1 Center Energy, Power, Environmental, and Access Control Monitoring Software In today s data center, being efficient with power and cooling resources is just as important as maintaining uptime. Power
More informationStruxureWare TM. Data Center Expert. Data Center Infrastructure Management (DCIM) Software
StruxureWare TM Data Center Expert Data Center Infrastructure Management (DCIM) Software End to end data center infrastructure management software for monitoring and control of power, cooling, security
More information1.0 Executive Summary
Statement of Work - 1 - Power and Cooling Assessment for Data Center Professional Services Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service
More informationData Center Infrastructure Management (DCIM) By Jesse Zhuo
Data Center Infrastructure Management (DCIM) By Jesse Zhuo Agenda The Evolution of DCIM Users Perspectives Management Methodology by Delta DCIM The Evolution of DCIM What is DCIM DCIM is software for Data
More informationDocument Management System
Document Management System Request for Proposal Maldives Transport and Contracting Company Plc. 7th Floor, MTCC Tower,Boduthakurufaanu Magu, Male' 0057, Maldives RFP No: MTCC-PD/IU/06/68 Page of 0 . EXECUTIVE
More informationSystem architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,
Datacenter Clarity LC Tech sheet Overview As part of the Integrated Data Center Management Suite (IDCMS), Datacenter Clarity LC * provides tools for operating and optimizing data centers. This includes:
More informationRequest for Proposal Technology Services, Maintenance and Support
Maintenance and Support April 26 th, 2018 Request for Proposal Technology Services, Maintenance and Support Celerity Schools Louisiana Inc. is seeking an IT consulting firm to manage Maintenance of our
More informationSystem architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,
Datacenter Clarity LC Tech sheet Overview Datacenter Clarity LC * is part of the Siemens BT Integrated Datacenter Management Suite (IDCMS). Clarity LC provides tools for operating and optimizing data centers,
More informationData Centre Solutions Expertly Engineered APC Management Software
Data Centre Solutions Expertly Engineered APC Management Software Data Centre Solutions Expertly Engineered A vendor neutral software suite, which provides a unified view and analysis of complex IT physical
More informationSALAMANDER. Automated Infrastructure Management
SALAMANDER Automated Infrastructure Management INNOVATION STARTS HERE Facemate is a market leader, providing customers with Data Center Solutions, Networking and Datacenter cabinets, DC Management Software,
More informationKako optimizovati operativni rad data
Sanja Milovanović, ENEL PS Dani tehnološkog umeća DATUM Beograd, 2017 Kako optimizovati operativni rad data Data Center Infrastructure Management DCIM centra 1 Data Center Management: Good Questions DC
More informationWhatsUp Gold. Evaluation Guide
WhatsUp Gold Evaluation Guide Table of Contents This guide provides and overview of WhatsUp Gold. Refer to our Online Help for more details. Section Step 1: Getting Started Description Installation requirements
More information10 BEST PRACTICES TO STREAMLINE NETWORK MONITORING. By: Vinod Mohan
10 BEST PRACTICES TO STREAMLINE NETWORK MONITORING By: Vinod Mohan 10 Best Practices to Streamline Network Monitoring Introduction As a network admin, you are tasked with keeping your organization s network
More informationPurchasing Department Finance Group INVITATION TO BID
Purchasing Department Finance Group August 7, 2012 INVITATION TO BID The City of Norwalk, Information Technology Department, is soliciting bids for Computer Server Hardware and VMware vsphere Enterprise
More informationForeScout Extended Module for Tenable Vulnerability Management
ForeScout Extended Module for Tenable Vulnerability Management Version 2.7.1 Table of Contents About Tenable Vulnerability Management Module... 4 Compatible Tenable Vulnerability Products... 4 About Support
More informationdctrack Proactively Manage, Control Change and Reduce Costs In Your Data Center Overview Benefits Fastest and Easiest User Interface
dctrack Proactively Manage, Control Change and Reduce Costs In Your Data Center Overview dctrack is a data center infrastructure management (DCIM) solution providing powerful and intelligent tools for
More information1.0 Executive Summary. 2.0 Features and Benefits
Table of Contents 1.0 EXECUTIVE SUMMARY 2.0 FEATURES AND BENEFITS 3.0 DETAILS OF SERVICE 4.0 Deliverable 5.0 Exclusions 6.0 SCOPE OF RESPONSIBILITY 7.0 PROJECT WORK DETAILS 8.0 ORDERING INFORMATION 9.0
More informationModius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis
Modius OpenData v3.3 Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis Modius Inc. 832 Folsom, Suite 1001 San Francisco, CA 94107 888.323.0066 info@modius.com www.modius.com
More informationSourcing Instructions for Suppliers: Reviewing and Responding to Negotiations
INFRASTRUCTURE MINING & METALS NUCLEAR, SECURITY & ENVIRONMENTAL OIL, GAS & CHEMICALS Sourcing Instructions for Suppliers: Reviewing and Responding to Negotiations Last Updated: 4-Jun-18 Level 4 - Public
More informationData Center Power Savings
Data Center Power Savings Data Center Power Savings Keith Mastrian, Regional Sales Manager, Raritan Data center power usage effectiveness (PUE), developed by The Green Grid, has received a lot of attention.
More informationARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management
ARTO LIND ABB Ability Datacenter Automation The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management Data Center common functionality DCIM needs to be open to handle
More informationUNL ebid # SCOPE OF WORK (CSN Network Management)
UNL has provided the following Scope of Work document in order to provide each bidder with specific and relevant background information related to this bid document. 1. History and Background a. The University
More informationStruxureWare TM Data Center Operation
StruxureWare TM Data Center Operation Data Center Infrastructure Management (DCIM) software for proactive data center life cycle management, optimizing existing capacities through intelligent resource
More informationAdministering isupport
Administering isupport Tracking and Monitoring isupport Usage Agents perform tasks in the background that are an integral part of isupport functionality. See Enabling and Scheduling Agents on page 2 for
More informationData Center Consultants for the upcoming IIT Bombay HPC+BYOH Data Center
Data Center Consultants for the upcoming IIT Bombay HPC+BYOH Data Center IIT Bombay Computer Center invites Data Center Consultants to submit their bids for the contract for the design and project management
More informationManagement Software. SmartView TM EMS (Element Management System) Management Software. Management Software. Polled Network Elements
Centralized Device Management Real-time visual representations and processing of alarms Long term event storage (up to 1 year) Easy, User-Friendly Operation Interface CTC Union s SmartView TM Element Management
More informationDCIM Data Center Infrastructure Management
DCIM Data Center Infrastructure Management Part 3 Operational Management Moves Adds and Changes & Electrical Infrastructure November 5, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Operational
More informationWelcome to the Vale Vendor Portal Guide
Welcome to the Vale Vendor Portal Guide 1. Introductory 1.1 How to access? 1.2 Presenting the Portal 2. Onboarding Process 3. Negotiate Module 4. Purchase Module 5. Payment Module 1. Introductory Main
More informationADDENDUM # 7 RFP DARK FIBER OPTIC CABLE INFRASTRUCTURE LEASE
September 25, 2013 (emailed to all proposers on this date) ADDENDUM # 7 RFP 021402 DARK FIBER OPTIC CABLE INFRASTRUCTURE LEASE Please note the following answers to questions that were asked prior to the
More informationEnergyLok Environmental Monitoring System 300 Product Training. Stephanie Christensen National Account Manager 03/24/16
EnergyLok Environmental Monitoring System 300 Product Training Stephanie Christensen National Account Manager 03/24/16 Introduction Environmental Monitoring Defined Consists of a variety of solutions developed
More informationStruxureWare TM Data Center Operation. A new level of business intelligence for your data center infrastructure management
StruxureWare TM Data Center Operation A new level of business intelligence for your data center infrastructure management Data Center Infrastructure Management (DCIM) software for proactive data center
More informationPower IQ DCIM Monitoring Version 6.2.1
Power IQ DCIM Monitoring Version 6.2.1 These Release Notes contain important information regarding the release of this product, so please read them carefully. We strongly recommend that you read the entire
More informationNMS300 Network Management System Application
NMS300 Network Management System Application Quick Start Guide October 2013 202-11288-02 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing
More informationMiami University Request for Proposal Data Center Infrastructure Manager (DCIM) System. 10/31/2014 Project Overview
Miami University Request for Proposal Data Center Infrastructure Manager (DCIM) System 10/31/2014 Project Overview Overview: Miami University consists of three campuses in southwest Ohio. The main campus
More informationManagement Software. SmartView TM EMS (Element Management System) 1-1. Management Software. Polled Network Elements
Management Software Centralized Device Management Real-time visual representations & processing of alarms Long term event storage (up to 1 year) Easy, User-Friendly Operation Interface CTC Union s SmartView
More informationGeist EMEA. Geist USA. Geist APAC
Product Overview Headquartered in Lincoln, Nebraska, Geist designs and manufactures industryleading technology and software to power, cool, monitor and manage critical data center infrastructure. We produce
More informationUnified Networks Administration & Monitoring System Specifications : YM - IT. YM Unified Networks Administration & Monitoring System
2115 YM Unified Networks Administration & Monitoring System 1. مواصفات نظام ادارة ومراقبة الشبكات الموحد: BOQ of Unified Networks Administration and Monitoring System: N 1 2 3 4 Item Main Network Monitoring
More informationSolicitation NUES Next Generation Firewall RFP. Bid designation: Public
Solicitation 2014-1 NUES Next Generation Firewall RFP Bid designation: Public Northeastern Utah 4/17/2014 2:07 PM p. 1 Bid Number 2014-1 Bid Title NUES Next Generation Firewall RFP NUES Next Generation
More informationBuilding Management System Application Datasheet
Building Management System Optergy Enterprise + Proton IP (Internet) 1 2 3 4 BACnetO MSTP R MODBUS RTU Description Optergy Building Management System (BMS), is software that allows users to monitor and
More informationI-9 AND E-VERIFY VENDOR DUE DILIGENCE
I-9 AND E-VERIFY VENDOR DUE DILIGENCE WHITE PAPER I-9 and E-Verify Vendor Due Diligence Key questions to ask electronic I-9 vendors to ensure you are making the best choice for your business. 1. Vendor
More informationFUJITSU Software ServerView Infrastructure Manager V2.2 Glossary
FUJITSU Software ServerView Infrastructure Manager V2.2 Glossary Edition 1.0 December 2017 CA92344-2053-01 FUJITSU LIMITED 1 / 7 Modification History Edition Publication Date Modification Overview 1.0
More informationPower Monitoring in the Data Centre
Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags
More informationNETWRIX PASSWORD EXPIRATION NOTIFIER
NETWRIX PASSWORD EXPIRATION NOTIFIER ADMINISTRATOR S GUIDE Product Version: 3.3 January 2013 Legal Notice The information in this publication is furnished for information use only, and does not constitute
More informationSmartView EMS. Central EMS. SmartConfig. Fault, Configuration, Accounting, Performance & Security Management (FCAPS)
SmartView EMS TM Fault, Configuration, Accounting, Performance & Security Management (FCAPS) Central EMS Expand EMS platform up to 50 SmartViewTM and 25,000 devices management SmartConfig TM Tool for quick
More informationOffice Adapters for Quark Publishing Platform
Office Adapters for Quark Publishing Platform Contents Getting started... 1 About Quark Publishing Platform...1 System requirements... 3 Installing the Office Adapters for Quark Publishing Platform...
More informationIOWA STATE UNIVERSITY OF SCIENCE AND TECHNOLOGY
IOWA STATE UNIVERSITY OF SCIENCE AND TECHNOLOGY Procurement Services Department 1340 Administrative Services Building 2221 Wanda Daley Drive Ames, Iowa 50011-3616 515 294-4860 FAX 515 294-9606 Date: August
More informationIntelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring
Intelligent infrastructure monitoring for software-defined data centers Intelligent Power Manager Infrastructure Simplified IT-centric monitoring Make more effective management decisions with intelligent
More informationPN5212/PN5320/PN7212/PN7320
PN522/PN520/PN722/PN720 Power Over the NET Power Distribution Units ALTUSEN Power Over the NET products are Power Distribution Units that offer outlet level control combined with remote access to give
More informationAdministrator s Guide
Blade Manager 4.1 Administrator s Guide ClearCube Technology, Inc. Copyright 2005, ClearCube Technology, Inc. All rights reserved. Under copyright laws, this publication may not be reproduced or transmitted
More informationStyle Report Enterprise Edition
INTRODUCTION Style Report Enterprise Edition Welcome to Style Report Enterprise Edition! Style Report is a report design and interactive analysis package that allows you to explore, analyze, monitor, report,
More informationServices Summary. Deliverables. Location of Services. Services Assumptions & Exclusions. General Project Management
Page 1 of 1 SERVICE DESCRIPTION: CISCO DNA CENTER ADVISE AND IMPLEMENT QUICK START ASF-EN1-G-DNAC-QS Services Summary Digital Network Architecture (DNA) Center Advise and Implement Quick Start assists
More informationBuilding a power monitoring and management strategy Selecting the software and services needed to keep critical power systems continuously available
White Paper Markets Served Data center & IT By Arthur Mulligan Product Line Manager, Eaton U.S. Power Quality Jim Tessier Product Manager, Eaton IT Hardware and Software Building a power monitoring and
More informationInstallation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment
Installation Service Statement of Work Start-up Service for Cooling Start-up - 1 - Service for Cooling Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0
More informationManagement Software. SmartView TM EMS (Element Management System) Management Software. Management Software SmartView TM EMS. Polled Network Elements
LAN PWR PWR 2 PoE Fault Fiber 00 LAN ON OFF Force Auto 0 00 Half Full LFP Flow Pass SW TX RX Ethernet Media Converter FIBER LAN PWR PWR 2 Fault Fiber 00 LAN ON OFF Force Auto 0 00 Half Full LFP Flow Pass
More informationRequest for Proposal (RFP) Toolkit
RFPToolkit Request for Proposal (RFP) Toolkit Table of Contents RFP Checklist......................................................... 2 6 Tips for Writing an RFP..............................................
More informationRequest For Proposal ONWAA Website & E-Learn Portal
Request For Proposal ONWAA Website & E-Learn Portal ONWAA 880 17 E, Garden River, Ontario P6A 6Z5 Table Of Contents General information Project Overview Statement of Needs Proposal Format Proposal Preparation
More informationHP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide
HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version
More informationWhat s New. New and Enhanced Features in NetSupport DNA v4. Welcome Dashboard. Auto Discovery. Platform Support
What s New New and Enhanced Features in NetSupport DNA v4 Welcome to NetSupport DNA version 4, the fresh approach to IT Asset Management. With any new release, the focus is not only on introducing innovative
More informationSecurely manage data center and network equipment from anywhere in the world.
LES1208A-R2 LES1216A-R2 LES1232A LES1248A-R2 8-/16-/32-/48-Port Advanced Console Servers QS Guide Securely manage data center and network equipment from anywhere in the world. Customer Support Information
More informationEngineering and Manufacturing Excellence in Data Centre Infrastructure
Engineering and Manufacturing Excellence in Data Centre Infrastructure Since 1982 Australia s Largest PDU Manufacturer NetSense DCIM Software Intelligent Power PDU s SafetyNet Series 5 CREMS E-Rack 19
More informationHelp for Suppliers. (UK Public Sector)
Help for Suppliers (UK Public Sector) Version 12.3 Copyright BravoSolution 2011, All Rights Reserved HELP FOR SUPPLIERS... 1 (UK PUBLIC SECTOR)... 1 HELP FOR SUPPLIERS (UK PUBLIC SECTOR)... 8 DASHBOARD
More informationEXAM Recertification for MCSE: Private Cloud. Buy Full Product.
Microsoft EXAM - 70-981 Recertification for MCSE: Private Cloud Buy Full Product http://www.examskey.com/70-981.html Examskey Microsoft 70-981 exam demo product is here for you to test the quality of the
More informationOnCommand Insight 7.2
OnCommand Insight 7.2 Planning Guide for the Java UI March 2016 215-10395_A0 doccomments@netapp.com Table of Contents 3 Contents OnCommand Insight Plan features... 5 OnCommand Insight product portfolio...
More informationSentry Power Manager (SPM)
Sentry Power Manager (SPM) SPM Release 5.0 2008-2011 Server Technology, Inc. All rights reserved. Instructions This symbol is intended to alert the user to the presence of important operating and maintenance
More informationGrant Parish School Board 512 Main Street P.O. Box 208 Colfax, LA 71417
Grant Parish School Board 512 Main Street P.O. Box 208 Colfax, LA 71417 Request for Proposals Wireless Network Upgrade and Expansion Grant Parish School Board (GPSB) is soliciting proposals for the products/services
More informationUsing SolarWinds Orion for Cisco Assessments
This PDF is no longer being maintained. Search the SolarWinds Success Center for more information. Using SolarWinds Orion for Cisco Assessments Cisco Network Assessments Registering Your Assessment...
More informationREQUEST FOR INFORMATION (RFI) ELECTRONIC FORMS AUTOMATION DEP Solicitation Number: C
Request for Information Electronic Forms Automation DEP RFI No.: 2016040C REQUEST FOR INFORMATION (RFI) ELECTRONIC FORMS AUTOMATION DEP Solicitation Number: 2016040C This is a Request for Information (RFI)
More informationHYCU SCOM Management Pack for Nutanix
HYCU SCOM Management Pack for Nutanix Product version: 2.5 Product release date: May 2018 Document edition: First Legal notices Copyright notice 2016-2018 HYCU. All rights reserved. This document contains
More informationForescout. Configuration Guide. Version 2.4
Forescout Version 2.4 Contact Information Forescout Technologies, Inc. 190 West Tasman Drive San Jose, CA 95134 USA https://www.forescout.com/support/ Toll-Free (US): 1.866.377.8771 Tel (Intl): 1.408.213.3191
More informationInitial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8
Contents Introduction 1 Before You Start 1 Overview 2 Supported devices 4 APC and User Local Area Networks (LANs) 5 Network Time Protocol (NTP) server feature 5 How to restore access to the server 6 Initial
More informationCopyright 2016 IPT PDUUM Revision
PDUUM052016 Revision 1.03.250516 Table of Contents Introduction...3 Warranty...3 Installation...3 Operation...3 View...4 Adding PDU Servers...4 Agent Information...5 Graphs...5 Log Views...5 Tools...5
More informationPredictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime
July 17, 2013 Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime siemens.com/answers Predictive Resilience Table of content What is DCIM & Its Business Value Extract Maximum
More informationRemote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products
Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products Learning Outcomes Need for Remote Management of Whitespace Understand Elements
More informationEnsuring a Successful DCIM Project. What You Need to Know. Paul Goodison CEO, Cormant Inc.
Ensuring a Successful DCIM Project. What You Need to Know. Paul Goodison CEO, Cormant Inc. Cormant DCIM and Interop Cormant DCIM Company Founded 2001 Delivering Infrastructure Management Solutions since
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More informationManagement Console User s Guide (AST 2500 Chipset)
Management Console User s Guide (AST 2500 Chipset) Version: 1.2 Table of Contents Using Your Management Console... 2 Management Console Key Features and Functions... 3 Software Install... 4 Prerequisites
More informationCity of Centralia, Missouri Website Design & Development
No. CEN19-AD01 City of Centralia, Missouri Website Design & Development City of Centralia 114 South Rollins Street Centralia, MO 65240 Phone: (573) 682-2139 Submittal Requirements The deadline for RFP
More informationDell EMC OpenManage Enterprise Version 3.0 Release Notes
Rev. A00 2018-09 This document describes the new features, enhancements, and known issues in Dell EMC OpenManage Enterprise version 3.0. Topics: Release type and definition Platforms affected What is supported
More informationLegal Notes. Regarding Trademarks KYOCERA MITA Corporation
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
More information1.1 ANNUAL DATA CENTER HEALTH CHECK
Statement of Work Maintenance Service 1.0 Executive Summary - 1 - Service Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service 4.0 Assumptions 5.0 Scope of Responsibility
More informationNetwork Configuration Manager
GETTING STARTED GUIDE Network Configuration Manager Version 7.7 Last Updated: Monday, October 9, 2017 Retrieve the latest version from: https://support.solarwinds.com/@api/deki/files/28214/orionncmgetstartedguide.pdf
More informationQUESTIONS AND CONTACTS
Contact: Jake Losinski, Management Analyst P.O. Box 2315 480 East Avenue North Ketchum, ID 83340 July 27, 2018 Telephone: (208) 727-5081 jlosinski@ketchumidaho.org SUBMITTAL DEADLINE The City of Ketchum,
More information