Newave s approach for protecting mission critical application

Size: px
Start display at page:

Download "Newave s approach for protecting mission critical application"

Transcription

1 ABB Technology Show, May 2013 Newave s approach for protecting mission critical application May 13, 2013 Slide 1

2 Contents Newave s company overview Electricity environment and trend Data Centre environment and trend TIER s level Motivational factors in Data Center (Newave approach) Differences between modular and modular UPS May 13, 2013 Slide 2

3 Company Profile May 13, 2013 Slide 3

4 Newave s facts and figures Swiss company Founded in 1993 become public in 2007 UPS is our business +200 employees 9 Subsidiaries +55 distributors worldwide Turnover 2011: 70 Mio Euro Since March 2012 Newave is Member of ABB group. May 13, 2013 Slide 4

5 Newave, the UPS trend s Pioneer Trend N 1* Transformerless UPS For the first time in the three-phase UPS market, revenues for transformerless three-phase UPS were greater than those for transformer-based three-phase in This shift in product topology was decisive, and is anticipated to continue to grow in coming years as the efficiency, size and manufacturing cost benefits of transformerless technology win over customers... *Source: IMS Research June 2010 Trend N 2** Modularity The financial crisis has given IT executives who are willing to make tough decisions a platform to significantly rationalize their data centre and IT infrastructure, and cut up to 50% of current costs, which they can potentially leverage into new investments to make their organization more efficient or competitive. ** Source: Steve Sams, VP Global Site and Facilities, IBM May 13, 2013 Slide 5

6 Electricity environment and trend May 13, 2013 Slide 6

7 The electrical energy trend Demand Quality Availability Dependency Cost May 13, 2013 Slide 7

8 The electricity s quality May 13, 2013 Slide 8

9 The electricity cost and trend May 13, 2013 Slide 9

10 Data Centres Environments and Trends May 13, 2013 Slide 10

11 Where does the energy goes within a DC? 1. Server racks 2. Climate control 3. Fire suppression 4. UPS systems 5. Backup generators 6. Security Source: The Green Grid's May 13, 2013 Slide 11

12 PUE Values Power usage effectiveness (PUE) is a metric used to determine the energy efficiency of a data center. PUE is determined by dividing the amount of power entering a data center by the power used to run the computer infrastructure within it. A PUE of 2.0 means that for every watt of IT power, an additional watt is consumed to cool and distribute power to the IT equipment. An ideal PUE would be 1.0. Average PUE has fallen from >2 to 1.5 Good PUEs in northern climes are Exceptional (enterprise facility) PUEs are 1.15 Unique PUE (Google, Facebook, Yahoo) are < 1.1 May 13, 2013 Slide 12

13 The Data Center power density and performance trend Power density trend of Datacom equipments is increasing creating difficulties to predict the future load affecting correct UPS rightsizing in advance. +9 years May 13, 2013 Slide 13

14 Downtime causes in IT environment May 13, 2013 Slide 14

15 Downtime costs in IT environment $ 150 Billion downtime cost/year worldwide May 13, 2013 Slide 15

16 UPS (Uninterruptible Power Supply) tasks UPS 1. Eliminate all power disturbances towards the critical load 2. Eliminate all power disturbances generated from the load upstream the UPS 3. Increase the power s availability towards the applied load May 13, 2013 Slide 16

17 TIER s level May 13, 2013 Slide 17

18 Availability s criteria, TIER levels Availability levels in Data Centre environment (TIER) May 13, 2013 Slide 18

19 Availability s criteria, TIER levels I II III IV May 13, 2013 Slide 19

20 Motivational factors in Data Center Newave approach May 13, 2013 Slide 20

21 IT managers concerns on UPS solution criteria for DC Availability TCO PUE Technology Footprint Flexibility Needed Power Standardisation May 13, 2013 Slide 21

22 Zerodowntime Issue 27 Sept/Oct 2008 May 13, 2013 Slide 22

23 Zerodowntime Issue 27 Sept/Oct 2008 Market Research from 21 DatacentreDynamics events across North America and EMEA decision makers involved in the design, construction & operation of critical datacentre facilities The Motivational Profile indicates the Key Priorities for the successful introduction of new technologies and solutions May 13, 2013 Slide 23

24 Datacentre Motivational Factors Reduce upfront costs USA Europe Reduce ongoing costs Increase energy efficiency Total Cost of Ownership #2 Improve control Cater for IT growth Repond to CSR/ environmental needs Maintain availability Flexibility #3 Availability #1 May 13, 2013 Slide 24

25 Contents Availability The degree to which a system is operable and in a committable state at the start of a mission, when the mission is called for at an unknown, i.e., a random time. Simply put, availability is the proportion of time a system is in a functioning condition. Source: Wikipedia A = E [Uptime] E [Uptime] + E [Downtime] May 13, 2013 Slide 25

26 UPS availability A = E [Uptime] E [Uptime] + E [Downtime] Mean Time Between Failure MTBF Mean Time To Repair MTTR UPS A = MTBF MTBF + MTTR May 13, 2013 Slide 26

27 High Power Availability UPS Requirements High Availability Online Double Conversion Topology Class VFI-SS-111 Fault Tolerance Redundancy through Decentralised Paralleling Rapid Recovery Low Mean Time To Repair through Modularity May 13, 2013 Slide 27

28 Availability Impact of Mean Time to Repair Traditional Free Standing (1+1) Redundant Configuration Traditional Free Standing (3+1) Redundant Configuration 120kVA 120kVA 40kVA 40kVA 40kVA 40kVA Critical Load = 120kVA Critical Load = 120kVA Availability: A = MTBFUPS / (MTBFUPS + MTTRUPS) Example 1 MTBF MTTR Availability Non - Modular (1+1) Redundant Configuration 600,000h 6h 0, (5 nines) Non - Modular (3+1) Redundant Configuration 400,000h 6h 0, (5 nines) May 13, 2013 Slide 28

29 Availability Impact of Mean Time To Repair Traditional Free Standing 2 x 120kVA (1+1) Redundant Configuration Advanced Modular 4 x 40kVA (3+1) Redundant Configuration Spare 40kVA Module 40kVA Module 40kVA Module 40kVA Module 120kVA 120kVA Critical Load = 120kVA Critical Load = 120kVA Availability: A = MTBFUPS / (MTBFUPS + MTTRUPS) Example 2 MTBF MTTR Non - Modular (1+1) Redundant Configuration 600,000h 6h Modular (3+1) Redundant Configuration 400,000h 0.5h Availability improved by an order of 10 Availability 0, (5 nines) 0, (6 nines) May 13, 2013 Slide 29

30 Datacentre Motivational Factors Reduce upfront costs USA Europe Reduce ongoing costs Increase energy efficiency Total Cost of Ownership #2 Improve control Cater for IT growth Repond to CSR/ environmental needs Maintain availability May 13, 2013 Slide 30

31 # 2 Total Cost of Ownership Total Cost of Ownership A statement on the financial impact of deploying information technology during its whole life-cycle; the acquisition and the ongoing costs. Source: Wikipedia May 13, 2013 Slide 31

32 # 2 Total Cost of Ownership (TCO) Freestanding Modular Capital Cost Full capacity at system commissioning Pay as you Grow Running Cost Sized to run at full capacity regardless of actual load Sized to run at optimal point on efficiency curve Floor Space Cost Lower power densities Horizontal paralleling Highest power densities Vertical paralleling Achieved by Rightsizing May 13, 2013 Slide 32

33 TCO - Rightsizing Freestanding Modular May 13, 2013 Slide 33 The limited flexibility of freestanding UPS systems require the initial installed power to be equal to the Datacentre s full capacity The flexibility of modular UPS systems to scale power makes it possible to add power as the Datacentre requirements grow

34 Efficiency (%) TCO Energy Efficiency For optimum efficiencies UPS systems should be greater than 50% loaded % 50% 75% 100% Load (%) Modular (Transformerless) Freestanding (Legacy) May 13, 2013 Slide 34

35 TCO Energy Efficiency Modular, Transformerless 4 x 40kVA (3+1) Redundant Configuration Spare 40kVA (32kW) Module 40kVA (32kW) Module 40kVA (32kW) Module 40kVA (32kW) Module Efficiency improved by 5% 120kVA (96kW) 120kVA (96kW) CRITICAL LOAD 96kW CRITICAL LOAD 96kW UPS UPS UPS UPS UPS UPS 96kW 96kW 50% Capacity 90% Efficiency 32kW 32kW 32kW 32kW 75% Capacity 95% Efficiency 48kW 48kW 24kW 24kW 24kW 24kW CRITICAL LOAD 96kW CRITICAL LOAD 96kW May 13, 2013 Slide 35

36 TCO Energy Efficiency Energy Cost typical commercial tariff = 0.1 /kwh Cooling factor = 0.4 Freestanding Modular Percentage load 50% 75% Efficiency 90% 95% Critical load 96 kw 96 kw Total UPS input power kw kw Total UPS heat loss 10.7 kw 5.1 kw UPS losses cost per year Cooling costs per year TOTAL COST PER YR May 13, 2013 Slide 36 Electricity saving over 5 years =

37 TCO Energy Efficiency Don t look only at the initial costs, but take also into consideration the TCO Source: Eurostat 2009 Efficiency difference 2% 3% 4% Load (kw) 5 years 10 years 5 years 10 years 5 years 10 years Energy cost savings kwh cost = 0.10 Cooling factors = 0.4 May 13, 2013 Slide 37

38 Datacentre Motivational Factors Reduce upfront costs USA Europe Reduce ongoing costs Increase energy efficiency Improve control Cater for IT growth Repond to CSR/ environmental needs Flexibility #3 Maintain availability May 13, 2013 Slide 38

39 # 3 Flexibility Flexibility The ability of a system to respond to potential internal or external changes affecting its value delivery, in a timely and cost-effective manner. The ease with which the system can respond to uncertainty in a manner to sustain or increase its value delivery. Uncertainty can create both risks and opportunities in a system, and Source: Wikipedia May 13, 2013 Slide 39

40 Client Case Study Initial load 100 kva 15 minute battery standby N + 1 redundancy Limited floor space 8m² maximum Datacentre is on the 5 th floor Running costs must be minimised Load expected to grow to 200kVA over the next 3 years May 13, 2013 Slide 40

41 Case Study Freestanding Option 100 kva / 15 Minute N+1 Redundancy 100 KVA UPS 100 KVA UPS I/P + O/P Switch Gear 15 Min Battery 15 Min Battery UPS UPS SG Batt Batt TOTAL Availability % Annual Losses Electricity Costs* Total Heat Loss (kw) kw Annual CO 2 Emissions 38 Tonnes Weight (kg) ,480 kg Floor Area (m 2 ) m2 * kwh cost = 0.10, Cooling factor = 0.4 May 13, 2013 Slide 41

42 15 15 Min Battery 15 Min Battery 15 Min Battery 15 Min Spare Battery Spare Spare Case Study Modular Solution 100 kva / 15 Minute N+1 Redundancy Spare Spare 50 kva UPS 50 kva UPS 50 kva UPS UPS Batt Batt TOTAL Availability % Annual Losses Electricity Costs* Total Heat Loss (kw) kw Annual CO 2 Emissions 21 Tonnes Weight (kg) ,900 kg Floor Area (m 2 ) m2 * kwh cost = 0.10, Cooling factor = 0.4 May 13, 2013 Slide 42

43 Case Study Freestanding Vs Modular Freestanding Modular Order of 10 Improvement % Availability % Annual Electricity Costs cost saving per year 10 kw Total Heat Loss (kw) 5.6 kw 44% less heat loss 38 Tonnes Annual CO 2 Emissions 21 Tonnes 17 Tonnes CO² saving per year 2,580kg less weight 47% 5,480 kg Weight (kg) 2,900 kg 2m² less space 44% 4.6 m2 Floor Area (m 2 ) 2.6 m2 May 13, 2013 Slide 43

44 Case Study Freestanding Vs Modular May 13, 2013 Slide 44 Freestanding Modular Availability Order of 10 Improvement % Availability % # cost saving per year Annual Electricity Costs Total Cost of Ownership #2 44% less heat loss 10 kw Total Heat Loss (kw) 5.6 kw 17 Tonnes CO² saving per year 38 Tonnes Annual CO 2 Emissions 21 Tonnes 2,580kg less weight 47% 5,480 kg Weight (kg) 2,900 kg 2m² less space 44% 4.6 m2 Floor Area (m 2 ) 2.6 m2

45 Case Study 2 Years after Oh Dear! Upgrade to Blade Servers means site load will now be increased by 40kVA What can I DO? May 13, 2013 Slide 45

46 15 15 Min Battery 15 Min Battery 15 Min Battery Min Battery Spare Spare Case Study 100 kva Load Increase Freestanding N+1 140kVA / 15 minutes 100 KVA UPS 100 KVA UPS 100 KVA UPS IP/OP Switch Gear 15 Min Battery 15 Min Battery 15 Min Battery Spare 50 kva UPS Flexibility #3 50 kva UPS 50 kva UPS 50 kva UPS May 13, 2013 Slide 46

47 Datacentre Motivational Factors Reduce upfront costs USA Europe Reduce ongoing costs Increase energy efficiency Total Cost of Ownership #2 Improve control Cater for IT growth Repond to CSR/ environmental needs Maintain availability Flexibility #3 Availability #1 May 13, 2013 Slide 47

48 Differences between modular and modular UPS May 13, 2013 Slide 48

49 Main differences between stand alone and Modular UPS Non modular Modular Flexibility Power increase flexibility Power decrease flexibility Tier changes flexibility Fast reconfiguration Availability On-Line UPS Parallel redundant Low MTTR Hot-Swap technology TCO Pay as you grow Vertical paralleling (low space) Product standardisation Optimized efficiency Reusable modules May 13, 2013 Slide 49

50 UPS s functional block (Standalone system) LCD Display Microprocessor Rectifier Battery Inverter Static by-pass May 13, 2013 Slide 50

51 UPS s functional block (Parallel system) Input Output May 13, 2013 Slide 51

52 A true modular UPS architecture (standalone system) A modular UPS is considered a TRUE modular only when each UPS module is equipped with all functional blocks (rectifier, inverter,static by-pass, LCD display, microprocessor) and with dedicated battery capability in order to avoid Single Point of Failure. May 13, 2013 Slide 52

53 A true modular UPS architecture (parallel system) Input Input Output Output May 13, 2013 Slide 53

54 A true modular UPS architecture (Operational) An hot swappable UPS module is the one which can be removed from the frame while it is powered on and does not require a reboot of the system, load transfer to raw mains or load s shut down A modular UPS is considered a TRUE modular only when the UPS modules are hot-swappable and the frame is full front accessible for service and maintenance purpose. May 13, 2013 Slide 54

55 A true modular UPS uses DPA Input Output Decentralized LCD display. DPA Decentralized microprocessor Decentralized battery Decentralized static by-pass May 13, 2013 Slide 55

56 The misconception of modular UPS architecture DPA CPA Input Output Input Output CPA CPA Input Output Input Output May 13, 2013 Slide 56

57 Modular UPS portfolio by Newave Modular: DPA UPSCALE Three-phase 10 and 20 kw(module) Safe swap from 10kW - 120kW Modular: CONCEPTPOWER DPA Three-phase 30, 40, 50kVA (module) Safe swap from 30kVA - 1,5 MVA Modular: DPA UPSCALE Three-phase 100kVA (module) Safe swap from 100kVA 1,2 MVA May 13, 2013 Slide 57

58 May 13, 2013 Slide 58

The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power. Alex Emms Operations Director

The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power. Alex Emms Operations Director The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power Alex Emms Operations Director Less UPS Drivers More UPS Drivers UPS Datacentre Drivers/Trends Datacentres =

More information

Zero downtime for mission critical applications? Absolutely.

Zero downtime for mission critical applications? Absolutely. Pierre-Alain Gubelmann, ABB Power Protection, Giornadas Tecnicas, Santiago de Chile, 11-12 Abril 2017 Zero downtime for mission critical applications? Absolutely. 2017-04-18 Slide 1 The Benefits of Modular

More information

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications Modular three-phase UPS system Conceptpower DPA 10 250 kva True modular UPS system for critical applications A UPS designed to meet the needs of today and tomorrow The Conceptpower DPA is a high-power,

More information

PowerWAVE 9000DPA. (30-50 kva) Parallelable up to 1.5 MVA

PowerWAVE 9000DPA. (30-50 kva) Parallelable up to 1.5 MVA PowerWAVE 9000DPA (30-50 kva) Parallelable up to 1.5 MVA Designed to meet the requirements of today and tomorrow. Key benefits Individual static switches per module Each module has its own display and

More information

PowerWAVE 9000DPA Designed to meet the requirements of today and tomorrow

PowerWAVE 9000DPA Designed to meet the requirements of today and tomorrow PowerWAVE 9000DPA Designed to meet the requirements of today and tomorrow PowerWAVE 9000DPA: Delivers class-leading Six Nines (99.9999%) power availability. PowerWAVE 9000DPA Up to 250 kva (200 kva N+1)

More information

PowerWave 9000DPA Designed to meet the requirements of today and tomorrow

PowerWave 9000DPA Designed to meet the requirements of today and tomorrow PowerWave 9000DPA Designed to meet the requirements of today and tomorrow PowerWAVE 9000DPA: Delivers class-leading Six Nines (99.9999%) power availability. PowerWAVE 9000DPA Up to 250 kva (200 kva N+1)

More information

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW PRODUCT BROCHURE Conceptpower DPA 500 480V UL Modular UPS 100kW 3MW 2 C O N C E P T P O W E R D PA 5 0 0 4 8 0 V M O D U L A R U P S Today s data centers require continuous uptime. That target is why ABB

More information

Product Brochure Eaton 93PR UPS kw

Product Brochure Eaton 93PR UPS kw Product Brochure Eaton 93PR UPS 25-200 kw For more than 50 years, Eaton has been safeguarding the critical systems of businesses across the globe. Whether protecting a single desktop or the largest data

More information

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW PRODUCT BROCHURE Conceptpower DPA 120 208V UL Modular UPS 20kW 600kW 2 CONCEPTPOWER DPA 120 280V MODULAR UPS Today s data centers require continuous uptime. That target is why ABB s Conceptpower DPA 120

More information

PowerWAVE 9500DPA. ( kva/kw) Parallelable up to 3 MVA/MW

PowerWAVE 9500DPA. ( kva/kw) Parallelable up to 3 MVA/MW PowerWAVE 9500DPA (100 500 kva/kw) Parallelable up to 3 MVA/MW 500 kva/kw modular UPS, designed with high effciency and maximum flexibility at its core. Total vertical and horizontal scalability using

More information

Est FlexiPower Ultra UPS FPX Ultra kVA

Est FlexiPower Ultra UPS FPX Ultra kVA Est.1968 FlexiPower Ultra UPS FPX Ultra 500 1000kVA Prepared by Thycon Industrial Pty Ltd. The Thycon FlexiPower Ultra boasts the lowest cost of ownership of any UPS system by offering energy efficiency,

More information

PowerWAVE 8000DPA Modular UPS designed for low and medium power applications

PowerWAVE 8000DPA Modular UPS designed for low and medium power applications PowerWAVE 8000DPA Modular UPS designed for low and medium power applications PowerWAVE 8000DPA is ideal for low to medium, high density critical power protection applications. For more information call

More information

Est FlexiPower Maxi. Modular UPS kw

Est FlexiPower Maxi. Modular UPS kw Est.1968 FlexiPower Maxi Modular UPS 8 200 kw Modular Parallel Architecture for missioncritical applications The rapid growth of data centers with mission critical applications that are fundamentally immune

More information

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW Product brochure Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW 2 Product brochure Conceptpower DPA 120 UL UPS Conceptpower DPA 120 The modular UPS for small and medium-sized data centers UPS

More information

Modularity in UPS Design What does it Mean, What are the Pro s and Con s?

Modularity in UPS Design What does it Mean, What are the Pro s and Con s? Modularity in UPS Design What does it Mean, What are the Pro s and Con s? Mike Elms Technical Manager Uninterruptible Power Supplies Ltd www.upspower.co.uk Modularity in UPS Design What does it Mean, What

More information

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology APM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology T M LIEBERT APM UPS Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can

More information

MGE Galaxy /900 kva

MGE Galaxy /900 kva MGE Galaxy 9000 800/900 kva Data centers are becoming increasingly large, Blade Servers are demanding more power, and there is increasing demand from semi conductors for the digital economy. The MGE Galaxy

More information

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager Power+ Family Products 1 P+ Family Products: Seth Davis- Global Marketing Manager Power+ Family Product line Power+ 10-20KVA 19 2 Mega Power+ 3 Power+ Family Product line Have you ever asked yourself what

More information

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology Liebert APM from 30 to 300 kw The Compact Row Based UPS With FlexPower Technology LIEBERT APM from 30 to 300 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the

More information

Modular and Scalable Power Converters in the UPS Industry

Modular and Scalable Power Converters in the UPS Industry A-PDF Split DEMO : Purchase from www.a-pdf.com to remove the watermark Modular and Scalable Power Converters in the Industry Ian Wallace Eaton Corporation, Innovation Center 1 Eaton Overview Eaton Electric

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

Est FlexiPower Maxi UPS FPX Maxi kVA

Est FlexiPower Maxi UPS FPX Maxi kVA Est.1968 FlexiPower Maxi UPS FPX Maxi 50 250kVA True modular UPS system for critical applications Designed and Published by Thycon. A UPS DESIGNED TO MEET THE NEEDS OF TODAY AND TOMORROW The FlexiPower

More information

LP 33 Series UPS. Digital Energy. GE Digital Energy

LP 33 Series UPS. Digital Energy. GE Digital Energy GE Digital Energy Digital Energy LP 33 Series UPS 40/60/80/100/120 kva three phase 400 Vac Active IGBT Rectifier & Active IGBT Rectifier Clean Input Module Uninterruptible Power Supply (UPS) imagination

More information

PowerWAVE 8000DPA. (10 20 kva/kw) Parallelable up to 400 kva/kw

PowerWAVE 8000DPA. (10 20 kva/kw) Parallelable up to 400 kva/kw PowerWAVE 8000DPA (10 20 kva/kw) Parallelable up to 400 kva/kw Modular UPS designed for low and medium power applications. Key benefits Individual static switches per module Each module has its own display

More information

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM Liebert NXr Series 30kVA to 160kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across

More information

DATA CENTER COLOCATION BUILD VS. BUY

DATA CENTER COLOCATION BUILD VS. BUY DATA CENTER COLOCATION BUILD VS. BUY Comparing the total cost of ownership of building your own data center vs. buying third-party colocation services Executive Summary As businesses grow, the need for

More information

Highly Efficient Power Protection for High Density Computing Applications

Highly Efficient Power Protection for High Density Computing Applications Highly Efficient Power Protection for High Density Computing Applications IB Power and Cooling Symposium Lennart Jonsson Eaton Corporation 2007 Eaton Corporation. All rights reserved. Impact of High Density

More information

Eaton Open Data Centre Solutions. Kari Koli

Eaton Open Data Centre Solutions. Kari Koli Eaton Open Data Centre Solutions Presenter: Stefan Coote Kari Koli 2008 Eaton Corporation. All rights reserved. Eaton Worldwide Founded in 1911 by J.O. Eaton World Headquarters in Cleveland, Ohio USA Customers

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

NEC Express5800 R320f Fault Tolerant Servers & NEC ExpressCluster Software

NEC Express5800 R320f Fault Tolerant Servers & NEC ExpressCluster Software NEC Express5800 R320f Fault Tolerant Servers & NEC ExpressCluster Software Downtime Challenges and HA/DR Solutions Undergoing Paradigm Shift with IP Causes of Downtime: Cost of Downtime: HA & DR Solutions:

More information

Nominee: Riello UPS with The Rosebery Group

Nominee: Riello UPS with The Rosebery Group Nominee: Riello UPS with The Rosebery Group Nomination title: Cutting Costs & Carbon Emissions With Modular UPS What was the driving force behind the project? Riello UPS is one of the world s leading manufacturers

More information

The Power of Modularity

The Power of Modularity Protectplus M600 The Power of Modularity to protect critical applications Protectplus M600 Flexible, scalable and smart It s our business to make your power security easy UPS systems from AEG Power Solutions

More information

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW PowerWAVE 9250DPA (50 250 N+1 kva/kw) Parallelable up to 1.5 MVA/MW True modular UPS for medium power applications in critical, high-density computing environments such as small to medium-sized data centres,

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns

More information

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns

More information

Switch to Perfection

Switch to Perfection Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of

More information

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM Liebert APM from 30-300 kw The Compact Row-Based UPS With FlexPower Technology TM Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative

More information

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,

More information

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications I E D Medium Size UPS As Dynamic As Your Business Small and medium sized businesses need UPS solutions that deliver

More information

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW AC Power For Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines

More information

Converged Power Solutions. Data center power reinvented

Converged Power Solutions. Data center power reinvented Converged Power Solutions Data center power reinvented always on anywhere anytime With Eltek s Converged Power Solutions, the next generation power solution for data centers is here. It offers unmatched

More information

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Data Center Trends: How the Customer Drives Industry Advances and Design Development Bablu Kazi, PE MORRISON HERSHFIELD MISSION CRITICAL Data Center Trends: How the Customer Drives Industry Advances and Design Development What does the Customer Need? Scalability P U E Latest Technology

More information

Mission Critical Power Review

Mission Critical Power Review Mission Critical Power Review Understanding concepts of mission critical power designs Chris Loeffler, ChrisALoeffler@Eaton.com Ed Spears, EdSpears@Eaton.com Power Quality Global HQ, Raleigh, NC Did you

More information

02 Why Does My IT Infrastructure Need a UPS?

02 Why Does My IT Infrastructure Need a UPS? UPS Buyer s Guide TABLE OF CONTENTS 01 What is a UPS? 02 Why Does My IT Infrastructure Need a UPS? 03 Common Features of UPS Systems ENERGY STORAGE SYSTEMS BATTERIES POWER PROTECTION MONITORING SOLUTIONS

More information

POWERING NETWORK RESILIENCY WITH UPS LIFECYCLE MANAGEMENT

POWERING NETWORK RESILIENCY WITH UPS LIFECYCLE MANAGEMENT POWERING NETWORK RESILIENCY WITH UPS LIFECYCLE MANAGEMENT Network downtime is a business disrupter, cutting off communication between employees and customers, bringing service delivery to a halt. Yet all

More information

Careful What You Wish For: Poor Colocation Design Could Cost You. Thorough assessment of upfront costs to prevent future system failures

Careful What You Wish For: Poor Colocation Design Could Cost You. Thorough assessment of upfront costs to prevent future system failures Careful What You Wish For: Poor Colocation Design Could Cost You Thorough assessment of upfront costs to prevent future system failures Introduction While IT professionals often disagree on design and

More information

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection Liebert EXS from 10 to 20 kw Optimized and integrated three-phase UPS solution with high efficiency power protection LIEBERT EXS from 10 to 20 kva Vertiv Vertiv designs, builds and services mission critical

More information

the Centric 300 An advanced modular UPS up to 1800kVA/kW

the Centric 300 An advanced modular UPS up to 1800kVA/kW the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has

More information

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc. Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc. Data Center Age Profile Gartner Group Survey Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery

More information

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution Liebert NXC from 10 to 200 kw Compact and Reliable Power in a Fully Integrated Packaged Solution LIEBERT NXC from 10 to 200 kva Vertiv Vertiv designs, builds and services mission critical technologies

More information

CPS VS UPS FOR POWERING DATA CENTERS

CPS VS UPS FOR POWERING DATA CENTERS CPS VS UPS FOR POWERING DATA CENTERS HOW THE ADVANTAGES OF A NO BREAK CONVERGED POWER SYSTEM (CPS) PROVIDED BETTER POWER RELIABILITY, SYSTEM AVAILABILITY AND REDUCED COSTS OVER A UNINTERRUPTABLE POWER

More information

MEASURE MONITOR UNDERSTAND

MEASURE MONITOR UNDERSTAND MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration

More information

Product Brochure Eaton 93PR UPS kw

Product Brochure Eaton 93PR UPS kw Product Brochure Eaton 93PR UPS 25-75 kw For more than 50 years, Eaton has been safeguarding the critical systems of businesses across the globe. Whether protecting a single desktop or the largest data

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable to 20 kw Modular, scalable, high-efficiency power protection for data centers The Symmetra TM PX 20 kw is a world-class, high-efficiency, ENERGY STAR qualified power protection system designed

More information

Power Quality Solutions Eaton 93PR UPS

Power Quality Solutions Eaton 93PR UPS Power Quality Solutions Eaton 93PR UPS Taking energy efficiency and scalability to the next level Eaton s heritage in industry-leading UPS design and production For more than 50 years, Eaton has been safeguarding

More information

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online

More information

Technology Changes in Data Centers

Technology Changes in Data Centers Technology Changes in Data Centers Mark Murrill Emerson Network Power TFI Conference, January 2014 Austin, TX 1 Agenda Market trends and impact on data center design Convergence around traditional telecom

More information

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM Liebert NX Series 30kVA to 200kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across

More information

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE ARCHIMOD HE 240/480 HIGH POWER MODULAR THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE superior performance continuity of service energy efficiency 2 Legrand, world leader in the

More information

Eaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved..

Eaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved.. Eaton 93PM: Value, Benefits, and Features 93PM value proposition The Eaton 93PM UPS combines unprecedented efficiency, reliability and vertical or horizontal scalability with eyecatching design. A space-saving,

More information

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Meeting the Energy Efficiency and Financial Challenges in IT. Liam Newcombe BCS Data Centre Specialist Group Secretary

Meeting the Energy Efficiency and Financial Challenges in IT. Liam Newcombe BCS Data Centre Specialist Group Secretary Meeting the Energy Efficiency and Financial Challenges in IT Liam Newcombe BCS Data Centre Specialist Group Secretary Meeting the Energy and Financial Challenges in IT Recognising the Problem Recognising

More information

Premium Power Protection LOAD PROTECTED LOAD PROTECTED

Premium Power Protection LOAD PROTECTED LOAD PROTECTED conceptpower Modular Premium Power Protection LOAD PROTECTED LOAD PROTECTED On demand power protection concept with scalable and redundant 10-100kVA hot-swappable modules for business-critical environments

More information

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the

More information

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM Powering Change in the Data Center A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Increases in data center density and diversity are driving change in the power and

More information

Data Centers. The Environment. December The State of Global Environmental Sustainability in Data Center Design

Data Centers. The Environment. December The State of Global Environmental Sustainability in Data Center Design Data Centers & The Environment The State of Global Environmental Sustainability in Data Center Design December 2018 Today s Data Centers Data centers have a huge impact on the world we live in. Today they

More information

Eaton BladeUPS 12 60kW

Eaton BladeUPS 12 60kW Power Quality Solution for Data Centres Eaton BladeUPS 12 60kW The power quality solution that simply grows with your needs Delivering power reducing costs Two key trends have emerged in the data centre:

More information

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends ABB Automation & Power World: April 18-21, 2011 CLP-101-1-CEU Myth Busting: The Truth behind Data Center Marketing Trends May 10, 2011 Slide 1 CLP-101-1-CEU Myth Busting: The Truth behind Data Center Marketing

More information

SAAS: THE RDP ADVANTAGE FOR ISVS AND USERS

SAAS: THE RDP ADVANTAGE FOR ISVS AND USERS SAAS: THE RDP ADVANTAGE FOR ISVS AND USERS How RDP SaaS deployment reduces costs, time to market and barriers to entry while improving security, performance and the UX Independent Software Vendors (ISVs)

More information

SystemTrust is the authorized distributor and partner of Borri UK in Nigeria

SystemTrust is the authorized distributor and partner of Borri UK in Nigeria SystemTrust is the authorized distributor and partner of Borri UK in Nigeria ONLINE DOUBLE CONVERSION UPS (800VA to 6.4MVA) SALES INSTALLATION SUPPORT MAINTENANCE Office: info@systemtrustng.com www.systemtrustng.com

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity Liebert NX from 30 to 60 kw AC Power for Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative solutions

More information

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution Liebert NXC 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution Regardless of your size, you can t afford for your critical business systems to go down and you can t waste time

More information

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services EMEA Roll-out 2 Main Mirror UK Swindon/Newbury area (15,000m 2 ) Germany Russelsheim(main)/

More information

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more

More information

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva

GE Consumer & Industrial Power Protection.   Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva GE Consumer & Industrial Power Protection Digital Energy LP Series UPS Uninterruptible Power Supply 3-30 kva GE imagination at work For more than a century, GE has led the way with innovative technologies

More information

Hitec QPS product range

Hitec QPS product range Hitec QPS product range Continuous Power Uninterrupted Power Quality Power Highest No-Break UPS Ratings Exceptional Power Density Modular Design Approach Best End-to-End Efficiency Optimized Availability

More information

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY OF CONTINUOUS SERVICE YEARS WARRANTY B8000 FXS 10-40kVA BORRI B8000 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

New Zealand Government IBM Infrastructure as a Service

New Zealand Government IBM Infrastructure as a Service New Zealand Government IBM Infrastructure as a Service A world class agile cloud infrastructure designed to provide quick access to a security-rich, enterprise-class virtual server environment. 2 New Zealand

More information

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW AC Power For Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines

More information

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500

More information

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social media increased demand for

More information

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW Liebert APM The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative

More information

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center

More information

IBM Site Enablement Services

IBM Site Enablement Services IBM Site Enablement Services Resilience for Your Data Centre 13/05/2005 Why Site Enablement Services? Hardware and Software are becoming increasingly dependable, but the environment in which they operate

More information

Maximizing Efficiency. In Data Centers

Maximizing Efficiency. In Data Centers Maximizing Efficiency In Data Centers Introduction: Efficiency Matters Introduction: Efficiency Matters When it comes to data center critical power, less is the new more. How can we get more power in less

More information

THE PATH TO LOWEST TOTAL COST OF OWNERSHIP WITH INDUSTRIAL AUTOMATION OPERATIONAL SYSTEMS. Avoiding Downtime with a Positive ROI

THE PATH TO LOWEST TOTAL COST OF OWNERSHIP WITH INDUSTRIAL AUTOMATION OPERATIONAL SYSTEMS. Avoiding Downtime with a Positive ROI THE PATH TO LOWEST TOTAL COST OF OWNERSHIP WITH INDUSTRIAL AUTOMATION OPERATIONAL SYSTEMS Avoiding Downtime with a Positive ROI Industrial Automation s Unique Challenges and the Risks of Unplanned Downtime

More information

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications APM UPS 18kW - 90kW The Flexpower Technology for mission critical applications WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable

More information

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity Liebert NX Series 30kVA to 200kVA AC Power For Business-Critical Continuity Liebert NX Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work

More information

Repeatable IT Hub Rooms

Repeatable IT Hub Rooms Repeatable IT Hub Rooms Repeatable IT Hub Rooms Catalogue Reducing the cost of NCPI through standardisation Data Centre Solutions Expertly Engineered Reducing the costs of NCPI through standardisation

More information

Overcoming the Challenges of Server Virtualisation

Overcoming the Challenges of Server Virtualisation Overcoming the Challenges of Server Virtualisation Maximise the benefits by optimising power & cooling in the server room Server rooms are unknowingly missing a great portion of their benefit entitlement

More information

ENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012

ENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012 ENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012 Robert (RJ) Meyers Data Center Products Lead ENERGY STAR Program US Environmental Protection Agency 1 Overview Main

More information

Liebert exm TM. 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

Liebert exm TM. 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications Efficient, Flexible Power Optimized For Medium Size UPS Applications Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster

More information

Mid-Sized Data Center UPS Solutions Overview

Mid-Sized Data Center UPS Solutions Overview Mid-Sized Data Center UPS Solutions Overview 2008 2008 Eaton Eaton Corporation. Corporation. All All rights rights reserved. reserved. Mid-Range System Concerns IT / ENGINEERS / BUYERS Cooling Designs

More information

CRITICAL INFRASTRUCTURE ASSESSMENTS

CRITICAL INFRASTRUCTURE ASSESSMENTS CRITICAL INFRASTRUCTURE ASSESSMENTS CRITICAL INFRASTRUCTURE ASSESSMENTS Critical Infrastructure Assessments Professional insight delivered by Vertiv experts will ensure that your infrastructure performs

More information

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Socomec Netys PR RT U P S TOWER / RACK MOUNT Socomec Netys PR RT Ideal solution for protecting small servers, networking devices and peripherals. Assures service continuity to critical applications. Designed for professional applications: the sinevawe

More information

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016 2016 COOLING THE EDGE SURVEY Conducted by Vertiv Publication Date: August 30, 2016 TWO STAGE POWER DISTRIBUTION Table of Contents Section I: Methodology Section II: Key Findings 1. Strategic Importance

More information

Performance Comparisons

Performance Comparisons UPS Topologies - Project Performance Comparisons Rowan Peck, NDY r.peck@ndy.com Overview Let s explore UPS solutions: Plant cost Quantity of redundant plant Building cost TCO energy, water, maintenance

More information