JUNXY Series DC Load Banks

Size: px
Start display at page:

Download "JUNXY Series DC Load Banks"

Transcription

1 JUNXY Series DC Load Banks It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, AC & DC generator, rectifier, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. So validating the condition and output of such power systems must be conducted comprehensively. JUNXY's constant current/power DC load banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other tests for DC power with loads. Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable. Models DC48V-50kW DC100V-50kW DC200V-100kW DC400V-200kW DC800V-400kW DC1000V-500kW Capacity 50KW 50KW 100KW 200KW 400KW 500KW Voltage DC48V DC100V DC200V DC400V DC800V DC1000V Current 1042A 500A 500A 500A 500A 500A Minimum Load 100W or 1A 100W or 1A 100W or 1A 1kW or 1A 1kW or 1A 1kW or 1A Step Digital Meter Voltage, Current and Power displayed by digital meter

2 Protections Optional Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button, All protections can be configured optionally Control Mode Local panel control Remote control(optional) Air Flow Force-air cooling Dimension 50*97*110(cm) 50*97*110(cm) 60*120*145(cm) 80*120*161(cm) 80*180*150(cm) 80*180*190(cm) Options Handle panel, PC remote control or timer selectable

3 JUNXY Series Rack Mounted Load Banks It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance. Critical power backup equipment like UPS System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. So validating the condition and output of such power systems must be conducted comprehensively. JUNXY provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything. Following on from construction and testing, Data Centre Commissioning is essential to ensure that the completed facility is configured for maximum efficiency. Missing out the essential Data Centre Commissioning can lead to an inefficient facility and higher than expected operational costs. By simply identifying where equipment manufacturers standard specifications are not appropriate for the IT load, the supporting infrastructure, in particular the cooling plant, can be configured to meet the requirements of the facility and lead to much higher levels of efficiency. Data centre commissioning can lead to significant energy savings when implemented correctly by a specialist commissioning team. By engaging JUNXY power solutions to ensure that systems are running correctly, clients have saved up to 67% on facility operational costs. The Junxy rack mounted AC & DC load banks are designed especially for internet data center (IDC) test and commissioning. Load bank integrated system test (IST) could precisely simulate the data center s electricity consumption, heat dissipation, air flow, hot & cold aisle testing, thus to ensure the effective operation of power supply & distribution system (generator, UPS, EPS included), air conditioning system, lightning protection and earthing system, monitoring system, data center integrated environments, cabinet IT environment, providing

4 independent verification of integrated system testing. Successful IST(integrated system test) should have installation of server load banks in data center and server room etc, Junxy provides resistive, reactive and capacitive load banks in low or medium voltage to cover the entire scope of your commission and testing requirements. Applications Data center & server room cooling system test Data center air flow, hot/cold aisle environment inspection Validating the tire level of data center Validating the reliability of data center power supply & distribution system Testing the main network before connecting user devices (servers, switches, etc.) Models AC120V-3KW AC230V-3KW AC230V-6KW AC230V-10.5KW DC270V-3KW DC270V-6KW Capacity 3KW 3KW 6KW 10.5KW 3KW 6KW AC120V AC230V DC270VDC Voltage Minimum 250W 250W 500W 500W 100W 100W Load Step Air Quantity 480CFM 480CFM 680CFM 1040CFM 680CFM 880CFM Dimension 3U 4U 6U 9U 4U 4U 19 Standard Rack Options Air flow control and display, digital meter, remote control Cables C13 C14

5 JUNXY Series Resistive AC Load Banks Purely resistive load bank is the most common type of load bank, and it proves equivalent loading of both generator and prime mover. That is, for each kilowatt of load applied to the generator by the load bank, an equal amount of electrical energy converts to heat by power resistors, in a general way, this heat must be dissipated from the load bank by air forced means or other convection. The Junxy's resistors are made by high quality finned tubular heating elements, they are of the type where the surface area is enlarged by a strip in order to heat gases. At high power the surface temperature is small and the heating element is short. Meanwhile, Load elements are cooled usually via Fan Forced Air, blower power is typically provided by an outside source. Selected load banks are available with blower power derived from the power source under test. Junxy's AC resistive load banks can be further divided into these categories: AC Small Portable: A resistive load bank easily carried or pushed on strong robust swivel wheels for testing and maintaining AC power equipment such as UPS systems and generators up to 150 KW. AC Large Portable: A resistive load bank on strong robust swivel wheels for testing and maintaining larger AC power equipment such as UPS systems and generators up to 1000 KW. AC Stationary: A resistive load bank for testing and maintaining AC power equipment such as UPS systems and generators at one location up to 4600 KW. Many models can be used as modular building blocks for applications requiring capacity of tens or hundreds of megawatts. Also the load banks can be loaded on a trailer for more flexibility. AC Medium/High Voltage: A resistive load bank for testing and maintaining larger generators and other AC power equipment up to 7000 KW and up to 15,000 volts

6 Models 220VAC-6KW-R 380VAC-30KW-R 380VAC-60KW-R 380VAC-100KW-R 380VAC-200KW-R 380VAC-400KW-R 6KW 30KW 60KW 100KW 200KW 400KW Capacity 220VAC 1P2W 380VAC 3P4W Voltage Current 1 phase: 27.2A 1 phase: 45.5A 3 phase: 136.5A 1 phase: 91A 3 phase: 272.7A 1 phase: 151.5A 3 phase: 454.5A 1 phase: 303A 3 phase: 909A 1 phase: 608A 3 phase: 1824A Frequency 50/60Hz PF PF=1 Minimum 100W 100W 100W 1KW 1KW 1KW Load Step Display Voltage, Current, Frequency, Power and PF displayed by digital meter Protection Overheating alarm, Short circuit protection, Overheating protection, Emergency stop button. All protections can be configured optionally Control Manual control by MCBs or button switches or toggle switches Mode Air Flow horizontal vertical horizontal horizontal horizontal horizontal Force-air cooling Dimension 49*60*21(cm) 50*67*116(cm) 51*97*110(cm) 81*97*155(cm) 80*120*161(cm) 80*180*150(cm) Options Handle panel or PC remote control selectable Ambient Maintains maximum capacity in ambient conditions up to 55, and 95% humidity parameters

7 JUNXY Series Resistive & Reactive AC Load Banks It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance. Critical power backup equipment like UPS System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. So validating the condition and output of such power systems must be conducted comprehensively. JUNXY provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything. JUNXY resistive & reactive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. For different testing purposes and applications, JUNXY mainly manufactures three kinds of resistive & reactive AC load banks: RL AC load bank, RLC AC load bank & RCD AC load bank. JUNXY Series Resistive & Inductive AC Load Banks JUNXY resistive & inductive AC load banks are used to simulate the motor loads or other Picture For Reference Only electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Models AC230V-6kW-RL AC480V-30kW-RL AC480V-60kW-RL AC480V-100kW-RL AC480V-200kW-RL AC480V-500kW-RL Capacity Resistive load: 6kW Resistive load: 30kW Resistive load: 60kW Resistive load: 100kW Resistive load: 200kW Resistive load: 500kW

8 4.5kVAR 22.5kVAR 45kVAR 75kVAR 150kVAR 375kVA Voltage Single Phase, AC230V Three Phase AC480V, or units can be specified by customer current at 480VAC per phase: 26A per phase: 20A per phase: 36A per phase: 27A per phase: 72A per phase: 54A per phase: 120A per phase: 90A per phase: 240A per phase: 180A per phase: 601A per phase: 451A PF PF=0.8(or customized power factor) Minimum 100W, 100VAR 100W, 100VAR 100W, 100VAR 1kW, 1kVAR 1kW, 1kVAR 1kW, 1kVAR Load Step Display Voltage, Current, Frequency, Power and PF displayed by digital meter Protection Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button. All protections can be configured optionally Control Manual control by MCBs or push buttons Mode Air Flow Horizontal, Force-air cooling Dimension 51*50*110(cm) 90*90*160(cm) 90*90*200(cm) 120*120*200(cm) 90*90*200(cm) 120*120*200(cm) Options Handle panel or PC remote control selectable

9 JUNXY Series Resistive, Inductive & Capacitive AC Load Banks JUNXY RLC load banks are mostly used for inverter anti-islanding test experiments which meets the PV & grid inverter testing requirements for islanding prevention detection, work efficiency test, overload protection test, over-current protection test, power factor test, grid current harmonic test, resonance point test, and so on. Both Leading power factor (Capacitive) and lagging power factor (Inductive) could be available with JUNXY series RLC AC load banks. Model JUNXY-AC480V-30kW-RLC JUNXY-AC480V-60kW-RLC JUNXY-AC480V-100kW-RLC Capacity Voltage Frequency PF Resistive load: 30kW 30kVAR Capacitive load: 30kVAR or units can be specified by customer Resistive load: 60kW 60kVAR Capacitive load: 60kVAR voltage Three Phase 480VAC, or units can be specified by customer 50Hz and 60Hz are available Resistive load: 100kW 100kVAR Min. load step 100W, 100VAR 1kW, 1kVAR 1kW, 1kVAR or units can be specified by customer Capacitive load: 100kVAR

10 JUNXY Series Resistive, Capacitive & Diode AC Load Banks JUNXY series RCD load banks are similar to a reactive load bank in rating and purpose, except that leading power factor loads are created. JUNXY RCD AC load banks are used to simulate the no-linear or electronic loads typically for the industires: telecommunication, computer, UPS, generator & invertor. To test the real load capacity & crest factor. JUNXY series RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test. Development of digitization and networking with today's society, Rectifier loads such as computers, network equipment is widely used. These load with nonlinear characteristics of rectifier-filter circuits, its value is not constant, power output range, stability is even more demanding. UPS power supply, inverter power supply for network devices, you must use the simulated load is nonlinear, to debug parameters such as its crest factor test. But traditional RLC simulated load based on linear load, unable to change characteristics of nonlinear load simulation, also makes it difficult to test the UPS power supply, inverter power supply, such as in a data center, network tension power performance in your environment. Only RCD nonlinear loads, power supply output power and power quality make the most accurate judgment. Models AC240V-10kW-RCD AC415V-30kW-RCD AC415V-60kW-RCD AC415V-100kW-RCD AC415V-250kW-RCD AC415V-400kW-RCD Capacity Resistive: 10kW Capacitive: 10kVAR Resistive: 30kW Capacitive: 30kVAR Resistive: 60kW Capacitive: 60kVAR Resistive: 100kW Inductive: 100kVAR Resistive: 250kW Inductive: 250kVAR Resistive: 400kW Inductive: 400kVA

11 Voltage Single Phase AC240V Three phase AC415V, or units can be designated by customer Maximum current 96A 1P: 96A 3P: 288A 1P: 192A 3P: 576A 1P: 319A 3P: 957A 1P: 798A 3P: 2394A 1P: 1278A 3P: 3834A Frequency 50/60 Hz PF PF= Minimum 100W, 100VAR 100W, 100VAR 100W, 100VAR 1kW, 1kVAR 1kW, 1kVAR 1kW, 1kVAR Load Step Display Voltage, Current, Frequency, Power and PF displayed by digital meter Protection Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button. All protections can be configured optionally Control Mode Manual control by MCBs or push buttons Air Flow Horizontal, Force-air cooling Dimension 51*63*120(cm) 51*97*120(cm) 80*140*185(cm) 80*140*185(cm) 80*150*155(cm) 80*150*190(cm) Important note for ALL ABOVE JUNXY series complete load bank solutions: Remote control function is optional AC & DC load voltage could be made compatible in ONLY one unit with several different load voltages. Circuit breaker, relay and contactor by ABB, Siemens, Schneider, Omron are optional as per requirements by clients. In some countries, 220V 1P will be replaced by 120V/230V/240V/277V 1P, 380V 3P will be replaced by 208V/400V/415V/480V 3P. Resistive AC load bank for load voltage 208V 3P and 120V 1P, 415V 3P and 240V 1P, 480V 3P and 277V 1P with higher load power are also available as per your need.

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,

More information

EP Series II UPS 230 V

EP Series II UPS 230 V EP Series II UPS 230 V 1000/2000/3000 VA Uninterruptible Power Supply (UPS) geindustrial.com Non-stop pure power Today s 24/7 business world depends on 24/7 power availability and demands zero down time.

More information

the Centric 300 An advanced modular UPS up to 1800kVA/kW

the Centric 300 An advanced modular UPS up to 1800kVA/kW the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has

More information

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY Three LEVEL UPS VFI TYPE PF=.0 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS True Three Level Rectifier and Inverter Technology

More information

Power System Network Simulator (PSNsim)

Power System Network Simulator (PSNsim) The PSNsim is hardware simulator that simulates all parts of power system from generation to utilization. The PSNsim is a scaled down model of the real power system that provides an experimental environment

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Powerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM)

Powerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM) Powerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM) Modbus Profile 164950161 Rev B Read Input Status Modbus Function Code 02 Input registers start at 10000. Register 1 On Battery 0 BOOL

More information

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY VFI TYPE PF= 0.9 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS Built In Inverter Transformer for DC-AC Galvanic Protection

More information

Liebert GXT MT kva

Liebert GXT MT kva Liebert GXT MT+ 10-20 kva Liebert GXT MT+ UPS, 10 kva - 20 kva Intelligent, Reliable UPS Protection Liebert GXT MT+ is a true on-line UPS that delivers continuous, high-quality AC power to connected equipment

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Technical Data SINVERT PVS2000

Technical Data SINVERT PVS2000 Technical Data SINVERT PVS2000 The solar inverter is used in PV systems to convert the direct current from the PV generators into a three-phase current. This three-phase current is then fed into the connected

More information

Intelligent On-Line UPS

Intelligent On-Line UPS Intelligent On-Line UPS Intelligent On-Line UPS Unity Input Power Factor Single-Chip Microprocessor Control Wide Input Voltage Range Pure Sinewave Output Smart RS-232 Communication Interface External Battery

More information

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Kohler EW 6000TX. Transformer-based. (UPS kVA) (UPS 10 600kVA) Three-phase UPS for computer rooms, data centres, precision instruments, and industrial processes. 10 200 kva PF = 0.9 Small footprint High effciency 92% All series touchscreen design Galvanic

More information

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology Liebert APM from 30 to 300 kw The Compact Row Based UPS With FlexPower Technology LIEBERT APM from 30 to 300 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)

More information

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Socomec Netys PR RT U P S TOWER / RACK MOUNT Socomec Netys PR RT Ideal solution for protecting small servers, networking devices and peripherals. Assures service continuity to critical applications. Designed for professional applications: the sinevawe

More information

This document describes the features and functional specifications of the ECONO3 air conditioner controller.

This document describes the features and functional specifications of the ECONO3 air conditioner controller. TITLE : FUNCTIONAL SPECIFICATION FOR ECONO3 COOL REV : 01 DATE : MARCH 13, 2001. 1. INTRODUCTION 1.1 Scope of Document This document describes the features and functional specifications of the ECONO3 air

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

HVD300 VOLTAGE DETECTION RELAY MULTIFUNCTIONAL PROTECTION MODULE USER MANUAL

HVD300 VOLTAGE DETECTION RELAY MULTIFUNCTIONAL PROTECTION MODULE USER MANUAL HVD300 VOLTAGE DETECTION RELAY MULTIFUNCTIONAL PROTECTION MODULE USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology

More information

Home Inrush Current Sensing Thermistor Tools About Video Library Blog. High Inrush Current Protection for Industrial Equipment

Home Inrush Current Sensing Thermistor Tools About Video Library Blog. High Inrush Current Protection for Industrial Equipment Page 1 of 11 Call Us: 775-884- 2434 Search for: Search Home Inrush Current Sensing Thermistor Tools About Video Library Blog Contact Us Blog» High Inrush Current Protection for Industrial Equipment High

More information

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity Galaxy VM 160/200 kva Parallel capable up to 800 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that

More information

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity Galaxy VM Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the electrical,

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX5000XLRT3U Highlights 5kVA / 5000VA line interactive 3U rack/tower

More information

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW) Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product

More information

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application MUST900 Modular UPS 30-300 kva modular UPS - up to 900 Datacenter & servers Internet centers Local Area Networks (LAN) Telecommunication devices Emergency application Smart Energy Solutions HOT SWAP 0.9

More information

Distribution Static Var Compensators and Static Synchronous Compensators for Suppressing Voltage Fluctuation

Distribution Static Var Compensators and Static Synchronous Compensators for Suppressing Voltage Fluctuation Distribution Static Var Compensators and Static Synchronous Compensators for Suppressing Voltage Fluctuation KOJIMA, Takehiko * ISOTANI, Hitoshi * YAMADA, Makoto * A B S T R A C T The rapidly expanding

More information

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology APM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology T M LIEBERT APM UPS Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Welcome to the features training module for ACS industrial drive modules.

Welcome to the features training module for ACS industrial drive modules. Welcome to the features training module for ACS880-04 industrial drive modules. 1 ACS880-04 single drive modules are optimized for easy and cost-efficient cabinet assembly. This power intensive drive module

More information

GAMATRONIC, A SolarEdge Division.

GAMATRONIC, A SolarEdge Division. GAMATRONIC, A SolarEdge Division. 17 Hartum Street, POB 45029, Jerusalem 9777517,Israel Tel: +972-2-5888222 Fax: +972-2-5828875 e-mail: info@gamatronic.com www.gamatronic.com The Power+ Premium 60 is

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

CI-tronic Reversing contactor Type RCI

CI-tronic Reversing contactor Type RCI Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast

More information

Smart Grid Tie Microinverter User Manual

Smart Grid Tie Microinverter User Manual Smart Grid Tie Microinverter User Manual Thanks for choosing Smart Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified by this user

More information

Document Title Issue Date. TBE/KBE-DOC TBE/KBE Document List TBE/KBE-REV TBE/KBE Revision List

Document Title Issue Date. TBE/KBE-DOC TBE/KBE Document List TBE/KBE-REV TBE/KBE Revision List Sid 1 (6) TBE/KBE DOCUMENT LIST Document Issue Date Supersedes TBE/KBE-DOC 12.0 2013-08-20 Issue 11.0 TBE/KBE-DOC TBE/KBE Document List 12.0 13-08-20 TBE/KBE-REV TBE/KBE Revision List 12.0 13-08-20 TBE/KBE

More information

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

SD250 VARIABLE SPEED DRIVE

SD250 VARIABLE SPEED DRIVE VARIABLE SPEED DRIVE SD250 Ranging from 0.4kW to 22kW, 200-230V and 380-480 Vac Easy programming and monitoring through cursors and digital display, removable up to 5m Wide range of accessories: RFI filter,

More information

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM Liebert NX Series 30kVA to 200kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across

More information

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics 150 W Dimmable DALI-2 LED driver DALI-2 certified LED driver, 1-100 % dimming range Filtered hybrid dimming technology Very high efficiency up to 96 % Low ripple and flicker (according to IEEE 1789) Suitable

More information

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home HYBRID PV INVERTERS HySpirit Series Hybrid Inverter with Battery Backup Smart Energy for Smart Home 4kW-10kW FSP HySpirit series Offers a more intelligent power solution for our customers to reduce the

More information

Schneider Electric Easy UPS 3S

Schneider Electric Easy UPS 3S Schneider Electric Easy UPS 3S Business continuity made easy 10 40 kva 380/400/415 V schneider-electric.com/ups Schneider Electric Easy UPS 3S The Schneider Electric Easy UPS 3S is an easy-to-install,

More information

AC-DC Converter REC /60-K20

AC-DC Converter REC /60-K20 Thanks to the variety of modules available, the REC3200-230-48-K20 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter

More information

ENCLOSURE HEAT DISSIPATION

ENCLOSURE HEAT DISSIPATION ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten

More information

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

USER MANUAL. Frequency Converter 15kVA 3x200V 400Hz Type AC/AC Frequency Converter

USER MANUAL. Frequency Converter 15kVA 3x200V 400Hz Type AC/AC Frequency Converter USER MANUAL Frequency Converter 15kVA 3x200V 400Hz Type 140331 EPS Stromversorgung GmbH FON +49 (0) 821-570 451-0 Alter Postweg 101 FAX +49 (0) 821-570 451-25 86159 Augsburg MAIL info@eps-germany.de Germany

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics 1x50 W Dimmable DALI LED driver Hybrid dimming technique for high quality light 50 W 220 240 V 0 / 50 Hz 60 Hz Suitable for use in emergency lighting applications DALI control input, 1 % - 100 % dimming

More information

AC-DC Converter RECE K21

AC-DC Converter RECE K21 Thanks to the variety of modules available, the RECE3200-230-48-K21 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter

More information

MGE Galaxy /900 kva

MGE Galaxy /900 kva MGE Galaxy 9000 800/900 kva Data centers are becoming increasingly large, Blade Servers are demanding more power, and there is increasing demand from semi conductors for the digital economy. The MGE Galaxy

More information

Giant ind. Robust Industry Online UPS. Robust Industry Online UPS

Giant ind. Robust Industry Online UPS. Robust Industry Online UPS Advancing Power Robust Industry Online UPS 3-phase in/single phase out 10kVA-120kVA 3-phase in/3-phase out (384VDC) 10kVA-200kVA 3-phase in/3-phase out (480VDC) 100kVA-600kVA Robust Industry Online UPS

More information

LL1x80-CR-DA. 80 W Dimmable DALI-2 LED driver. 80 W V 0 / Hz. Functional Description. Mains Characteristics

LL1x80-CR-DA. 80 W Dimmable DALI-2 LED driver. 80 W V 0 / Hz. Functional Description. Mains Characteristics 80 W Dimmable DALI-2 LED driver Product code: 5559 80 W 220 240 V 0 / 50 60 Hz DALI-2 certified LED driver, 1-100 % dimming range Filtered hybrid dimming technology Very high efficiency up to 9 Low ripple

More information

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications APM UPS 18kW - 90kW The Flexpower Technology for mission critical applications WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable

More information

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

ASTRASUN Series Single Phase String Inverter

ASTRASUN Series Single Phase String Inverter ASTRASUN Series Single Phase String Inverter Model (ASTRASUN) 1500TL 2000TL 2500TL 3000TL 3600TL 5000TL 6000TL Max. DC input power 1750W 2300W 2700W 3660W 3750W 5300W 6400W Max. DC voltage 450Vdc 500Vdc

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Development of Small Capacity UPS, "SANUPS 001 ASC"

Development of Small Capacity UPS, SANUPS 001 ASC 1 / 6 SANYO DENKI Technical Report No.5 May 1998 Feature Development of Small Capacity UPS, "SANUPS 001 ASC" Yoshihiro Wada Chiaki Seki Hitoshi Yoshiike Akira Yajima 1. Introduction Computers are becoming

More information

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Medium Voltage Metal-Enclosed Harmonic Filter Systems 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Harmonic Filter Systems General NEPSI s armorvar, medium voltage metal-enclosed

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications Modular three-phase UPS system Conceptpower DPA 10 250 kva True modular UPS system for critical applications A UPS designed to meet the needs of today and tomorrow The Conceptpower DPA is a high-power,

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 38W 5-7mA flexc lp ACED series Product description Built-in constant current ED Driver Adjustable output current between 5 and 7 ma Max. output power 38 W Up to 85 % efficiency ominal life-time

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Product availability : Stock - Normally stocked in distribution facility Price* : 1468.00 USD Main Range

More information

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES 1. Introduction Real time monitoring and control is necessary to ensure public and employee safety and to protect the integrity

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

A. Advanced Features. Configurable High Power Solution

A. Advanced Features. Configurable High Power Solution Sorensen HPX Series High Power Extensible Programmable DC Series 36 kw - 240 kw 10-1000 V 45-6000 A Advanced Features High Power Density: Up to 150KW in a single bay rack-mount cabinet. Up to 240KW in

More information

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9 SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9 MODEL NUMBER: SUINT2000XLCD Highlights Zero transfer time suitable for advanced network

More information

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) The CP-B 24/20.0 serves to ensure a shortterm uninterrupted power supply

More information

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks General NEPSI's activar, Medium

More information

MGE Galaxy 5000 for emergency lighting and power equipment

MGE Galaxy 5000 for emergency lighting and power equipment MGE Galaxy 5000 for emergency lighting and power equipment UL 924 listed UPS and battery systems schneider-electric.com 2 schneider-electric.com State-of-the-art three-phase power protection designed to

More information

Product Specifications

Product Specifications Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin

More information

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD3U Description Tripp Lite Smart Online UPS systems

More information

DPA UPSCALE TM RI kw Technical Specifications

DPA UPSCALE TM RI kw Technical Specifications DPA UPSCALE TM RI 10-80 kw Technical Specifications Edition 18.06.2012 Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 DPA UPScale RI SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS

More information

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR MODEL NUMBER: SU3000RTXL2U Highlights Zero transfer time between AC power and battery

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 57W 8-5mA flexc lp ACED series Product description Built-in constant current ED Driver ew version DC operating with E marking Adjustable output current between 8 and,5 ma Max. output power 57

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation

More information

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Fronius IG Plus. The next generation grid-connected PV inverter.

Fronius IG Plus. The next generation grid-connected PV inverter. Fronius IG Plus The next generation grid-connected PV inverter. Maximum earnings. In any weather. The first multi-purpose device. Reliability and maximum earnings security. An outstanding addition to the

More information

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America MODEL NUMBER: SU80KTV Highlights 80,000 VA (80kVA) tower UPS with 4 hot-swappable power

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 69W 35-5mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 35 and 5 ma Max. output power

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 7W 5-35mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 5 and 35 ma Max. output power

More information

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SUINT3000RTXL2U Description 3000VA / 3kVA / 2500 watt on-line, double-conversion

More information

Schneider Electric Easy UPS 3S

Schneider Electric Easy UPS 3S Schneider Electric Easy UPS 3S Business continuity made easy 10 40 kva 380/400/415 V schneider-electric.com/ups Business continuity made easy The Schneider Electric Easy UPS 3S is an easy-to-install, easy-to-use,

More information

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW AC Power For Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines

More information