1 EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007 Applied Technology Abstract This white paper discusses the EMC CLARiiON LUN shrinking feature in detail. It captures the business benefits and advantages of LUN shrinking by exploring the possibilities of integrating this feature in a typical Microsoft Exchange production environment. July 2010

2 Copyright 2010 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com All other trademarks used herein are the property of their respective owners. Part Number: h8009 Applied Technology 2

3 Table of Contents Executive summary... 4 Introduction... 4 Audience... 4 Terminology... 4 Overview of LUN shrinking... 5 Host-side shrinking process... 5 Array-side shrinking process... 7 Additional considerations for LUN shrinking LUN shrinking with Microsoft Exchange Conclusion References Applied Technology 3

4 Executive summary This white paper discusses the advantages of using the EMC CLARiiON FLARE release 29 feature called LUN shrinking within a typical Microsoft Exchange production environment. This paper discusses the requirements and important considerations of LUN shrinking and explains the business benefits achieved by using this feature to increase the performance and usability of CLARiiON with Microsoft Exchange. LUN shrinking provides a significant advantage to storage provisioning by allowing the space in the storage array to be reused if it is no longer required by the application that was originally using it. LUN shrinking benefits organizations by creating higher storage utilization by reclaiming unused storage space. Secondly, LUN shrinking helps in green storage initiatives by minimizing the need for additional storage, hence saving cost and power. In the past, CLARiiON did not have a native solution to shrink the LUNs associated with Windows 2008 Disk Management. As a result, even after Windows OS level shrinking, the storage space on the array was still allocated. LUN shrinking is a CLARiiON feature introduced in FLARE release 29. This feature targets the unused space in the LUN, reduces the size of the LUN, and thus improves the storage utilization. Introduction This white paper gives information about the different aspects of LUN shrinking. The paper is designed to equip the reader with the necessary understanding to maximize the CLARiiON storage environment in a cost-effective way before seeking additional storage arrays. This paper gives a scenario of Microsoft Exchange 2007 using a CLARiiON CX4-480 with LUN shrinking to simulate a production environment. The purpose is to understand the impact and benefits of LUN shrinking in a Microsoft Exchange environment. This white paper explores the LUN shrinking feature and covers the following topics: The importance of LUN shrinking The benefits of shrinking a LUN (from a user perspective) The impact of the LUN shrink operation on the back-end storage objects A case study of shrinking the LUNs associated with Microsoft Exchange 2007 The EMC CLARiiON Storage System Fundamentals for Performance and Availability Applied Best Practices white paper provides specific information on FLARE, CLARiiON provisioning, LUNs, and RAID groups. Audience This white paper is targeted at customers, including storage architects, administrators, and others who may be involved in evaluating, acquiring, managing, operating, or designing an EMC networked storage environment. Terminology This section provides a brief description of the common terms used in this paper. LUN: A logical unit whose storage capacity is set at the time of creation. A LUN is created from a RAID group. LUN shrinking: A feature that is used to reduce the LUN size and increase the available disk space. Windows Server 2008: The most recent release of the Microsoft Windows Server operating system that includes a volume shrink feature, which allows users to reduce the size of a file system (volume and partition) and the underlying storage (LUN). Applied Technology 4

5 Virtual Disk Service (VDS) Provider: A VDS Provider that is used by Windows Server 2008 VDS to perform hardware provisioning and management operations. Thin Pool: A user-defined object that reserves and groups disks together for use by the Thin Provisioning feature. There may be 0 or more Thin Pools on a system. A disk can be a member of only one Thin Pool at a time. Disks that are members of a Thin Pool cannot be part of a RAID group. Thin LUN (TLU): A LUN that can grow storage capacity by using a shared pool of storage (Thin Pool), when required. EMC Solutions Enabler: A set of application programming interface (API) libraries that provide an interface between the software applications and the heterogeneous hardware and software infrastructure within a storage environment. Overview of LUN shrinking In the past, third-party tools such as Partition Magic were used to manage Windows-based disk partitions. The third-party tools required an external boot process to Microsoft operating systems from bootable CDs. These tools allowed disk reformatting and partition extension and reduction. Unlike previous Microsoft operating systems, Windows Vista and Windows Server 2008 allow an easy, out-of-the-box method to shrink partitions. The shrink feature in Disk Management is used to free up unused disk space to create another partition from the saved space. This feature functions in a similar way for both normal and dynamic disks. It enables administrators to manage Windows storage requirements, which is one of the more challenging administration areas. However, before FLARE release 29, even if the drive space was reduced from the host side, the array-side space allocation was not altered. This created a need for an array-side LUN shrinking feature. The following steps are involved in the LUN shrinking process when the storage is provisioned to a Windows system using storage arrays like CLARiiON. 1. Shrinking the drive space on the host side using the Windows Server 2008 Disk Management console. 2. Shrinking or destroying the metaluns or FLARE LUNs on the array side using the LUN shrinking feature. Host-side shrinking process Prior to Microsoft Windows Server 2008 and Microsoft Windows Vista, the server-side disk partitions were shrunk using third-party applications and the diskpart command line tool. But now this can be done in the Disk Management console within Windows Server 2008 Server Manager. During the shrinking operation, the data that is spread across the volume is moved so that it uses contiguous space at the beginning of the disk partition. This allows the unallocated space from the end of the disk partition to be freed up. Applied Technology 5

6 The first step in LUN shrinking is to perform a user-level volume shrink operation on Windows Server 2008 Disk Management. The following procedure explains this process. 1. In the Disk Management console, right-click the disk and select Shrink Volume. The Shrink dialog box appears. Figure 1 Disk Management 2. The available amount of free space in MB is displayed. Type the appropriate size lower than the available size and click Shrink. The disk partition shrinks to the required size. Figure 2 Shrink After the volume shrinks, the size of the drive reduces from the Disk Management console. But the unallocated space can be seen from the console because it is not removed from the array side. Figure 3 Drive size after shrinking At this point, the host-side activity is completed and the LUN size must be reduced on the array side using array features. Applied Technology 6

7 Array-side shrinking process After the volume size is reduced on the host, the Microsoft Windows Server 2008 diskraid command is used to shrink the CLARiiON LUN. This command in turn uses the VDS Provider to shrink the CLARiiON LUNs. Note: EMC VDS Provider Release Notes provides more information on the CLARiiON VDS Provider. CLARiiON LUN shrinking using the diskraid command and VDS Provider The steps to perform the array-side shrink process are: 1. On the Windows host, run the diskraid command from the command prompt. Figure 4 diskraid command 2. List the providers using the list providers command. Figure 5 list providers command 3. Select the required provider (FC or iscsi) based on the host and the array connectivity by using the select provider X command. Figure 6 select provider command 4. List the storage subsystems by using the list subsystems command. Figure 7 list subsystem command 5. Select the required subsystem by using the select subsys x command. Figure 8 select subsystem command Applied Technology 7

8 Note: The subsystem is displayed twice when listed because the array supports both FC and iscsi connectivity. To use the right connectivity to an array, use the detail provider command after selecting the subsystem. In the output, if the name of the provider is EMC VDS Hardware Provider, then FC connectivity is used to interact with the array. If iscsi connectivity is used, select the other instance. 6. List all the existing LUNs by using the list luns command. Figure 9 list luns command 7. Select the LUN corresponding to the device number to execute the shrink operation by using the select lun x command. Figure 10 select lun command Note: The LUN number on the array side and the host side may be different. The LUN number for the device may vary for every diskraid session. The device number must match the disk number displayed in the console. Select the LUN for which the device number matches the disk number. 8. Shrink the selected LUN by using the shrink lun size Y command, where Y is the size to be shrunk. Figure 11 shrink lun command 9. Verify the new size of the LUN by observing the LUN size using the list LUN command. 10. Verify the new LUN size on the array. For this, navigate to C:\Program Files\EMC\SYMCLI\bin and type in the following command: naviseccli h ipaddr getlun LUNnumber capacity 11. The LUN size after shrinking is visible in the Disk Management console. Figure 12 Before shrinking Applied Technology 8

9 Figure 13 After shrinking Shrinking metaluns MetaLUNs are made by joining a base FLARE LUN to one or more component FLARE LUNs. The component FLARE LUNs can be a part of the same RAID group or different RAID groups. The LUNs can be concatenated or striped together to create a metalun. The shrinking behavior is different in striped and concatenated metalun components. Striped metalun In a striped metalun, the component LUNs are striped together in groups with a single operation. All the base LUN data is equally distributed by striping across all LUNs. Striped metaluns improve the performance as well as protection. CLARiiON writes to all LUNs in the metalun at the same time. The workload of the application is spread out across the backend of the CLARiiON, thereby increasing the speed. Figure 14 shows how shrinking works in striped metalun components. Figure 14 LUN shrinking in striped metaluns After the shrink operation, each component will be shrunk by an equal size and the components will not be eliminated from the metalun. In a striped metalun, even though the space is reduced, the existing striping is maintained between the components. For example, a metalun is created by striping three 10 GB LUNs from different RAID groups, as shown in Figure 15. Applied Technology 9

10 Figure 15 metalun configuration This results in a metalun of 30 GB, as shown in Figure 16. Figure 16 metalun In this drive, 12 GB of space is shrunk as shown in Figure 17. Figure 17 Shrinking the metalun After shrinking through VDS, the drive size is updated at the OS level. Figure 18 Drive size The metalun capacity is also updated at the CLARiiON level. Figure 19 Capacity changes in the component LUNs Out of the three 10 GB component LUNs, each LUN is shrunk by 4 GB. This way, the space is equally shrunk in each of the component LUNs. Applied Technology 10

11 Concatenated metaluns In a concatenated metalun, each added component LUN is appended as a new addressable capacity of the metalun s base component. Concatenated metaluns can use component LUNs that are of a different RAID types and RAID sizes. In this case, CLARiiON writes only to one LUN at a time. LUN shrinking can be done on metaluns to free up the storage space. Figure 20 shows how the shrink operation works in a concatenated metalun s components. Figure 20 LUN shrinking in a concatenated metalun The LUN shrinking feature will shrink space from the components that are added from the last to the first. Components that are less than the shrinking capacity are unbound and removed from the metalun. To claim the space from the unbound LUNs, the RAID groups where the unbound LUNs were created must be defragmented. For example, a 40 GB LUN is created by concatenating three LUNs: one 5 GB, one 15 GB, and one 20 GB LUN from different RAID groups. Concatenation involves combining LUNs from different RAID groups instead of a single RAID group. Figure 21 MetaLUN configuration This metalun is shown as 40 GB when it is presented to the host as a drive. Applied Technology 11

12 Figure 22 MetaLUN presented as a drive When performing a volume shrink, the amount of space to shrink is specified as 17 GB instead of the default available shrink size of 20 GB. Figure 23 Shrinking the metalun After the volume shrink, a partition of 17 GB is created on the drive. Figure 24 After host side shrinking After the LUN shrinking is done using the diskraid command, the capacity changes are made at the CLARiiON level. On the metalun, of the three LUNs (5 GB, 15 GB, and 20 GB), the 5 GB LUN is removed and the 20 GB LUN is shrunk to 8 GB. The shrunk size of the 20 GB LUN is highlighted in Figure 25. Figure 25 Component LUN size after shrinking Based upon our study of the previous scenarios, the shrinking process of the CLARiiON LUN depends on whether the LUNs are combined using striping or concatenation. In the case of striped metaluns, after shrinking, the remaining space is equally distributed to the component LUNs. But in the case of the concatenated metalun, the shrinking feature removes the least sized component LUN and shrinks the remaining space from the component LUN that was added last into the meta. Applied Technology 12

13 Additional considerations for LUN shrinking The following points on supportability, performance, and resiliency must be considered for all LUN shrinking use cases: LUN shrinking is currently supported only in Microsoft Windows Server Note: This is true at the time this document is written. The capacity changes due to LUN shrinking occur as a background process. A shrink operation will not be automatically restarted in the event of a system failure. Currently the LUN shrinking feature is not directly available through Navisphere Manager. Because the command works through the CLI, there is no visible progress update of the operation. CLARiiON private LUNs, snaps, clones, and mirrors cannot be shrunk. CLARiiON spin down must not be enabled for the LUN that is to be shrunk. A single shrink request can be done at a time for each RAID group. There may be many shrink requests running in parallel for different RAID groups. There should be no trespassing, that is, changing the ownership of the LUNs during the LUN shrinking process. There must be a difference of at least 16 MB from the current internal capacity for a shrink request to be successful. LUN shrinking with Microsoft Exchange is usually considered as an ever-expanding and never-shrinking pool of loosely structured information. As users, we have become accustomed to large attachments, and being able to instantly go back to a conversation to reference some important information. This context seems to be an odd place to talk about shrinking LUNs. On the other hand, expanding the LUNs seems like a much better idea here. With the introduction of EMC SourceOne archiving for Exchange, it becomes clear why LUN shrinking can be useful here. High-speed production storage is expensive for IT departments, and most Exchange deployments use plenty of it. EMC SourceOne allows older data and large chunks of data-like attachments to be replaced with shortcuts in Exchange that refer to the same object on a less expensive tier of storage. In this case, we may wonder what to do with the heavily under-utilized and very expensive LUNs, which until recently held all this data. This is where LUN shrinking comes into the picture. Obviously, we must not shrink the LUNs to their minimum size because mail storage tends to grow. But, if you need to reallocate some storage, LUN shrinking can be very useful. Note: Shrinking an Exchange database by the default free size will result in a minimally sized LUN, which will immediately cause the Exchange server to unmount the database. The following tests simulate a typical Exchange environment with 2,000 mailboxes and a very heavy user profile workload. To understand how LUN shrinking is performed, a basic understanding of the database disk configuration is required. There are four component LUNs in the database metalun. Each database metalun is 335 GB, and the component LUNs are 83 GB. Using Microsoft LoadGen, a user activity was simulated for 10 hours. In the middle of the LoadGen test, the database LUN size was reduced by 100 GB. After the CLARiiON LUN shrinking operation was completed, the database disk shrunk to 235 GB as expected. At the CLARiiON level, out of the four component LUNs of 83 GB, the last LUN was removed. After shrinking, the remaining component LUNs were as follows: two 83 GB LUNs and one 67 GB LUN. Applied Technology 13

14 Figure 26 LoadGen test During the test run, LUN shrinking was performed. There were no execution errors reported during or after the test run. Databases were not dismounted. The result shows that there was no downtime for Exchange databases and Outlook users due to LUN shrinking. The variation of database disk I/O operations per second (IOPS) is illustrated in Figure 27: Figure 27 Exchange database IOPS The number of completed IOPS declined by approximately 30 percent during the test. So, it is recommended to complete shrinking operations during the non-peak hours. Figure 28 shows the variation of read and write latencies on the database LUN. Applied Technology 14

15 Figure 28 Exchange database read/write latencies The average database write latency showed a minimal impact due to the shrink operation. However, the database read latency, which is often a reliable proxy for customer experience, shows a 67 percent increase during the operation. This supports the recommendation from the previous result that while a shrink operation can be executed sucessfully while under load, it must be scheduled for non-peak hours, if possible. Conclusion LUN shrinking will significantly improve the storage utilization of a system by enabling storage administrators to reclaim any unused storage space inside a CLARiiON LUN. LUN shrinking is a two-step process that needs to be started from the host side and completed on the array side. This paper describes the steps to shrink a CLARiiON LUN. Overprovisioning storage to business-critical applications is a common practice in the implementation of high-performance storage solutions. Tests conducted with business-critical applications like Microsoft Exchange prove that using the LUN shrinking feature will have minimum performance impact on the applications with zero data loss. This allows the allocation of storage space to closely match the actual needs of the application. By reducing the amount of unused capacity available to high-performing applications, businesses can realize improved storage efficiency and reduce their total cost of ownership for the solution. References EMC VDS Provider Release Notes EMC CLARiiON Best Practices for Performance and Availability: Release 29.0 Firmware Update Applied Best Practices white paper EMC CLARiiON Storage System Fundamentals for Performance and Availability Applied Best Practices white paper EMC CLARiiON MetaLUNs A Detailed Review white paper Applied Technology 15

EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy. Applied Technology

EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy. Applied Technology EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy Applied Technology Abstract This white paper highlights a new EMC Celerra feature that simplifies the process of creating specific custom

More information

EMC Solutions for Microsoft Exchange 2007 NS Series iscsi

EMC Solutions for Microsoft Exchange 2007 NS Series iscsi EMC Solutions for Microsoft Exchange 2007 NS Series iscsi Applied Technology Abstract This white paper presents the latest storage configuration guidelines for Microsoft Exchange 2007 on the Celerra NS

More information

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and VMware s Distributed

More information

MIGRATING TO DELL EMC UNITY WITH SAN COPY

MIGRATING TO DELL EMC UNITY WITH SAN COPY MIGRATING TO DELL EMC UNITY WITH SAN COPY ABSTRACT This white paper explains how to migrate Block data from a CLARiiON CX or VNX Series system to Dell EMC Unity. This paper outlines how to use Dell EMC

More information

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN White Paper VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN Benefits of EMC VNX for Block Integration with VMware VAAI EMC SOLUTIONS GROUP Abstract This white paper highlights the

More information

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and

More information

VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S

VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S Implementation Guide EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com

More information

EMC Business Continuity for Microsoft Applications

EMC Business Continuity for Microsoft Applications EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3. EMC Backup and Recovery for Microsoft Exchange 2007 SP1 Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.5 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

EMC Solutions for Microsoft Exchange 2007 CLARiiON CX3 Series iscsi

EMC Solutions for Microsoft Exchange 2007 CLARiiON CX3 Series iscsi EMC Solutions for Microsoft Exchange 2007 CLARiiON CX3 Series iscsi Best Practices Planning Abstract This white paper presents the best practices for optimizing performance for a Microsoft Exchange 2007

More information

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15 EMC SAN Copy Command Line Interface (CLI) Reference P/N 069001189 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2010 EMC Corporation.

More information

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011 EMC CX4 Series Storage Systems Disk and FLARE OE Matrix P/N 300-007-437 REV A17 February 22, 2011 To function properly, disks in an EMC CLARiiON system require that each storage processor run minimum revisions

More information

EMC VNX2 Deduplication and Compression

EMC VNX2 Deduplication and Compression White Paper VNX5200, VNX5400, VNX5600, VNX5800, VNX7600, & VNX8000 Maximizing effective capacity utilization Abstract This white paper discusses the capacity optimization technologies delivered in the

More information

EMC Celerra Virtual Provisioned Storage

EMC Celerra Virtual Provisioned Storage A Detailed Review Abstract This white paper covers the use of virtual storage provisioning within the EMC Celerra storage system. It focuses on virtual provisioning functionality at several levels including

More information

Exchange 2003 Archiving for Operational Efficiency

Exchange 2003 Archiving for Operational Efficiency Exchange 2003 Archiving for Operational Efficiency Enabled by EmailXtender Reference Architecture EMC Global Solutions Operations EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000

More information

EMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120 and VMware vsphere 4.0 using iscsi

EMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120 and VMware vsphere 4.0 using iscsi EMC Virtual Infrastructure for Microsoft Exchange 27 Enabled by EMC CLARiiON CX4-12 and Applied Technology Abstract This white paper details a solution built and tested using EMC CLARiiON CX4-12 and VMware

More information

EMC SAN Copy Command Line Interfaces

EMC SAN Copy Command Line Interfaces EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All

More information

EMC FAST CACHE. A Detailed Review. White Paper

EMC FAST CACHE. A Detailed Review. White Paper White Paper EMC FAST CACHE A Detailed Review Abstract This white paper describes EMC FAST Cache technology in CLARiiON, Celerra unified, and VNX storage systems. It describes the implementation of the

More information

EMC CLARiiON Backup Storage Solutions

EMC CLARiiON Backup Storage Solutions Engineering White Paper Backup-to-Disk Guide with Computer Associates BrightStor ARCserve Backup Abstract This white paper describes how to configure EMC CLARiiON CX series storage systems with Computer

More information

Release Notes P/N REV A01 August 11, 2010

Release Notes P/N REV A01 August 11, 2010 EMC Unisphere Analyzer Version 1.0.0 Release Notes P/N 300-011-113 REV A01 August 11, 2010 These release notes contain supplemental information about EMC Unisphere Analyzer, version 1.0.0. Topics include:

More information

EMC Business Continuity for Microsoft Exchange 2010

EMC Business Continuity for Microsoft Exchange 2010 EMC Business Continuity for Microsoft Exchange 2010 Enabled by EMC Unified Storage and Microsoft Database Availability Groups Proven Solution Guide Copyright 2011 EMC Corporation. All rights reserved.

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007 Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange Server Enabled by MirrorView/S and Replication Manager Reference Architecture EMC

More information

Implementing Virtual Provisioning on EMC Symmetrix with VMware Infrastructure 3

Implementing Virtual Provisioning on EMC Symmetrix with VMware Infrastructure 3 Implementing Virtual Provisioning on EMC Symmetrix with VMware Infrastructure 3 Applied Technology Abstract This white paper provides a detailed description of the technical aspects and benefits of deploying

More information

Using EMC FAST with SAP on EMC Unified Storage

Using EMC FAST with SAP on EMC Unified Storage Using EMC FAST with SAP on EMC Unified Storage Applied Technology Abstract This white paper examines the performance considerations of placing SAP applications on FAST-enabled EMC unified storage. It also

More information

Here is Your Customized Document

Here is Your Customized Document Here is Your Customized Document Your Configuration is: Manage LUNs Model - VNX5300 Storage Type - VNX for Block (SAN) Connection Type - Fibre Channel Switch or Boot from SAN Operating System - ESX Server

More information

Optimizing Tiered Storage Workloads with Precise for Storage Tiering

Optimizing Tiered Storage Workloads with Precise for Storage Tiering Applied Technology Abstract By introducing Enterprise Flash Drives to EMC Symmetrix and CLARiiON storage systems, EMC revitalized the importance of tiered storage. Optimizing the use of these tiers provides

More information

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager Reference Architecture Copyright 2010 EMC Corporation. All rights reserved.

More information

DELL EMC UNITY: DATA REDUCTION

DELL EMC UNITY: DATA REDUCTION DELL EMC UNITY: DATA REDUCTION Overview ABSTRACT This white paper is an introduction to the Dell EMC Unity Data Reduction feature. It provides an overview of the feature, methods for managing data reduction,

More information

EMC Solutions for Microsoft Exchange 2003 CX Series iscsi

EMC Solutions for Microsoft Exchange 2003 CX Series iscsi EMC Solutions for Microsoft Exchange 2003 CX Series iscsi Best Practices Planning Guide Abstract This white paper presents the best practices for optimizing the performance for Exchange 2003 storage configuration

More information

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA EMC SAN Copy Command Line Interface P/N 069001189 REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2009 EMC Corporation. All rights reserved.

More information

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE Applied Technology Abstract This white paper is an overview of the tested features and performance enhancing technologies of EMC PowerPath

More information

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005 Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Long Distance Recovery for SQL Server 2005 Enabled by Replication Manager and RecoverPoint CRR Reference Architecture EMC Global

More information

Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated

Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated EMC Solutions for Microsoft Exchange 2007 Virtual Exchange 2007 in a VMware ESX Datastore with a VMDK File Replicated Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated EMC Commercial

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange in a VMware Environment Enabled by MirrorView/S Reference Architecture EMC Global

More information

Drive and FLARE OE Matrix

Drive and FLARE OE Matrix EMC CX4 Series Storage Systems and FLARE OE Matrix P/ N 300-007-437 To function properly, drives in an EMC CLARiiON system require that each storage processor run minimum s of the FLARE Operating Environment

More information

Microsoft Office SharePoint Server 2007

Microsoft Office SharePoint Server 2007 Microsoft Office SharePoint Server 2007 Enabled by EMC Celerra Unified Storage and Microsoft Hyper-V Reference Architecture Copyright 2010 EMC Corporation. All rights reserved. Published May, 2010 EMC

More information

Using EMC CLARiiON CX4 Disk-Drive Spin Down with EMC Celerra FAST

Using EMC CLARiiON CX4 Disk-Drive Spin Down with EMC Celerra FAST Using EMC CLARiiON CX4 Disk-Drive Spin Down with EMC Celerra FAST Applied Technology Abstract This white paper highlights the ability to use the CLARiiON disk-drive Spin Down feature with EMC Celerra to

More information

OPTIMIZING CLOUD DEPLOYMENT OF VIRTUALIZED APPLICATIONS ON EMC SYMMETRIX VMAX CLOUD EDITION

OPTIMIZING CLOUD DEPLOYMENT OF VIRTUALIZED APPLICATIONS ON EMC SYMMETRIX VMAX CLOUD EDITION White Paper OPTIMIZING CLOUD DEPLOYMENT OF VIRTUALIZED APPLICATIONS ON EMC SYMMETRIX VMAX CLOUD EDITION Simplifies cloud storage Automates management and provisioning Transforms as-a-service delivery EMC

More information

EMC Virtual Infrastructure for Microsoft Exchange 2007

EMC Virtual Infrastructure for Microsoft Exchange 2007 EMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC Replication Manager, EMC CLARiiON AX4-5, and iscsi Reference Architecture EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103

More information

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Reference Architecture EMC Global Solutions

More information

LEVERAGING EMC FAST CACHE WITH SYBASE OLTP APPLICATIONS

LEVERAGING EMC FAST CACHE WITH SYBASE OLTP APPLICATIONS White Paper LEVERAGING EMC FAST CACHE WITH SYBASE OLTP APPLICATIONS Abstract This white paper introduces EMC s latest innovative technology, FAST Cache, and emphasizes how users can leverage it with Sybase

More information

EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives

EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper demonstrates

More information

EMC Integrated Infrastructure for VMware. Business Continuity

EMC Integrated Infrastructure for VMware. Business Continuity EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.

More information

Release Notes P/N REV A04 July 7, 2006

Release Notes P/N REV A04 July 7, 2006 cre EMC CX-Series SnapView For FLARE OE Version 02.19.yyy Release Notes P/N 300-002-753 REV A04 July 7, 2006 These release notes contain supplemental information about the following EMC products: SnapView

More information

EMC CLARiiON CX3 Series FCP

EMC CLARiiON CX3 Series FCP EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2008

More information

Introduction to the CX700

Introduction to the CX700 Engineering White Paper Introduction to the CX700 Abstract This white paper introduces the full 2 Gb architecture and functionality of the CX700 storage system. It compares the features and capabilities

More information

EMC Virtual Infrastructure for Microsoft SharePoint Server 2010 Enabled by EMC CLARiiON and VMware vsphere 4

EMC Virtual Infrastructure for Microsoft SharePoint Server 2010 Enabled by EMC CLARiiON and VMware vsphere 4 EMC Virtual Infrastructure for Microsoft SharePoint Server 2010 Enabled by EMC CLARiiON and VMware vsphere 4 A Detailed Review EMC Information Infrastructure Solutions Abstract Customers are looking for

More information

PESIT Bangalore South Campus

PESIT Bangalore South Campus PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Information Science & Engineering SOLUTION MANUAL INTERNAL ASSESSMENT TEST 1 Subject & Code : Storage Area

More information

Surveillance Dell EMC Storage with Digifort Enterprise

Surveillance Dell EMC Storage with Digifort Enterprise Surveillance Dell EMC Storage with Digifort Enterprise Configuration Guide H15230 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published August 2016 Dell believes the

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes the steps required to deploy a Microsoft Exchange Server 2013 solution on

More information

Surveillance Dell EMC Storage with FLIR Latitude

Surveillance Dell EMC Storage with FLIR Latitude Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information

More information

Lenovo SAN Manager - Provisioning and Mapping Volumes

Lenovo SAN Manager - Provisioning and Mapping Volumes Lenovo SAN Manager - Provisioning and Mapping Volumes Lenovo ThinkSystem DS2200, DS4200, DS6200 June 2017 David Vestal, WW Product Marketing Lenovo.com/systems Table of Contents Introduction... 2 Provisioning

More information

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS A detailed overview of integration points and new storage features of vsphere 5.0 with EMC VNX platforms EMC Solutions

More information

Reference Architecture

Reference Architecture EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com

More information

White Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft

White Paper. A System for  Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS

More information

TECHNICAL OVERVIEW OF NEW AND IMPROVED FEATURES OF EMC ISILON ONEFS 7.1.1

TECHNICAL OVERVIEW OF NEW AND IMPROVED FEATURES OF EMC ISILON ONEFS 7.1.1 TECHNICAL OVERVIEW OF NEW AND IMPROVED FEATURES OF EMC ISILON ONEFS 7.1.1 ABSTRACT This introductory white paper provides a technical overview of the new and improved enterprise grade features introduced

More information

EMC Virtualized Architecture for Microsoft Exchange Server 2007 with VMware Virtual Infrastructure 3 and EMC CLARiiON CX4-960

EMC Virtualized Architecture for Microsoft Exchange Server 2007 with VMware Virtual Infrastructure 3 and EMC CLARiiON CX4-960 EMC Virtualized Architecture for Microsoft Exchange Server 2007 with VMware Virtual Infrastructure 3 and EMC CLARiiON CX4-960 Best Practices Planning Abstract This white paper presents best practices and

More information

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009

More information

EMC Corporation. Tony Takazawa Vice President, EMC Investor Relations. August 5, 2008

EMC Corporation. Tony Takazawa Vice President, EMC Investor Relations. August 5, 2008 1 EMC Corporation Tony Takazawa Vice President, EMC Investor Relations August 5, 2008 2 Forward-Looking Statements This presentation contains forward-looking statements as defined under the Federal Securities

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1 Copyright 2011, 2012 EMC Corporation. All rights reserved. Published March, 2012 EMC believes the information in this publication

More information

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers By Todd Muirhead Dell Enterprise Technology Center Dell Enterprise Technology Center dell.com/techcenter

More information

EMC Management for SAP TDMS Enabled by EMC CLARiiON with Virtual Provisioning and EMC Replication Manager

EMC Management for SAP TDMS Enabled by EMC CLARiiON with Virtual Provisioning and EMC Replication Manager EMC Management for SAP TDMS Enabled by EMC CLARiiON with Virtual Provisioning and EMC Replication Manager A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper demonstrates

More information

Dell EMC SAN Storage with Video Management Systems

Dell EMC SAN Storage with Video Management Systems Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for

More information

SQL Server 2008 Consolidation

SQL Server 2008 Consolidation Technology Concepts and Business Considerations Abstract The white paper describes how SQL Server 2008 consolidation provides solutions to basic business problems pertaining to the usage of multiple SQL

More information

Recommendations for Aligning VMFS Partitions

Recommendations for Aligning VMFS Partitions VMWARE PERFORMANCE STUDY VMware ESX Server 3.0 Recommendations for Aligning VMFS Partitions Partition alignment is a known issue in physical file systems, and its remedy is well-documented. The goal of

More information

Transitioning Exchange 2003 to VMware Virtual Exchange 2007 Using EMC CLARiiON or EMC Celerra

Transitioning Exchange 2003 to VMware Virtual Exchange 2007 Using EMC CLARiiON or EMC Celerra Transitioning Exchange 2003 to VMware Virtual Exchange 2007 Using EMC CLARiiON or EMC Celerra Best Practices Planning Abstract This white paper describes the transition of a physical Exchange 2003 or 2000

More information

Surveillance Dell EMC Storage with Bosch Video Recording Manager

Surveillance Dell EMC Storage with Bosch Video Recording Manager Surveillance Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide H13970 REV 2.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published December

More information

3.1. Storage. Direct Attached Storage (DAS)

3.1. Storage. Direct Attached Storage (DAS) 3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.

More information

EMC Disk Library Automated Tape Caching Feature

EMC Disk Library Automated Tape Caching Feature EMC Disk Library Automated Tape Caching Feature A Detailed Review Abstract This white paper details the EMC Disk Library configuration and best practices when using the EMC Disk Library Automated Tape

More information

EMC ViPR Controller. Integration with VMAX and VNX Storage Systems Guide. Version REV 01

EMC ViPR Controller. Integration with VMAX and VNX Storage Systems Guide. Version REV 01 EMC ViPR Controller Version 2.3 Integration with VMAX and VNX Storage Systems Guide 302-002-075 REV 01 Copyright 2013-2015 EMC Corporation. All rights reserved. Published in USA. Published July, 2015 EMC

More information

EMC CLARiiON Asymmetric Active/Active Feature (ALUA)

EMC CLARiiON Asymmetric Active/Active Feature (ALUA) A Detailed Review Abstract This white paper provides an overview of the EMC CLARiiON Asymmetric Active/Active feature. It highlights the configuration, best practices, implementation details of EMC PowerPath,

More information

Managing VNX Block Storage

Managing VNX Block Storage This chapter contains the following sections: VNX Block Storage Management, page 1 Summary of Steps, page 2 Storage Pools, page 3 RAID Groups, page 4 Host Initiators, page 6 Storage Groups, page 8 LUNs,

More information

INTRODUCTION TO THE VVNX COMMUNITY EDITION

INTRODUCTION TO THE VVNX COMMUNITY EDITION INTRODUCTION TO THE VVNX COMMUNITY EDITION A Detailed Review ABSTRACT This white paper introduces the architecture and functionality of the EMC vvnx Community Edition. This paper also discusses some of

More information

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5 White Paper INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5 EMC GLOBAL SOLUTIONS Abstract This white paper describes a simple, efficient,

More information

BACKUP AND RECOVERY FOR ORACLE DATABASE 11g WITH EMC DEDUPLICATION A Detailed Review

BACKUP AND RECOVERY FOR ORACLE DATABASE 11g WITH EMC DEDUPLICATION A Detailed Review White Paper BACKUP AND RECOVERY FOR ORACLE DATABASE 11g WITH EMC DEDUPLICATION EMC GLOBAL SOLUTIONS Abstract This white paper provides guidelines for the use of EMC Data Domain deduplication for Oracle

More information

Managing VNX Block Storage

Managing VNX Block Storage This chapter contains the following sections: VNX Block Storage Management, page 1 Summary of Steps, page 2 Storage Pools, page 3 RAID Groups, page 4 Host Initiators, page 6 Storage Groups, page 8 LUNs,

More information

Veritas Storage Foundation for Windows by Symantec

Veritas Storage Foundation for Windows by Symantec Veritas Storage Foundation for Windows by Symantec Advanced online storage management Data Sheet: Storage Management Overview Veritas Storage Foundation 6.0 for Windows brings advanced online storage management

More information

Hitachi Dynamic Provisioning The Unofficial Best Practice Guide

Hitachi Dynamic Provisioning The Unofficial Best Practice Guide Hitachi Dynamic Provisioning The Unofficial Best Practice Guide V1.3 1 Contents 1. Introduction 2. Pool Pre-requisites and Restrictions 3. Pool Performance 4. DP-VOL size recommendations 5. Other Considerations

More information

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture. Deploying VMware View in the Enterprise EMC Celerra NS-120 EMC NAS Product Validation Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2009 EMC Corporation.

More information

Veritas Storage Foundation from Symantec

Veritas Storage Foundation from Symantec Simplified, Scalable and Cost-Effective Storage Management Overviewview provides a complete solution for heterogeneous online storage management. Based on the industry-leading Veritas Volume Manager from

More information

EMC Celerra Replicator V2 with Silver Peak WAN Optimization

EMC Celerra Replicator V2 with Silver Peak WAN Optimization EMC Celerra Replicator V2 with Silver Peak WAN Optimization Applied Technology Abstract This white paper discusses the interoperability and performance of EMC Celerra Replicator V2 with Silver Peak s WAN

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

EMC Backup and Recovery for Oracle Database 11g Enabled by EMC Celerra NS-120 using DNFS

EMC Backup and Recovery for Oracle Database 11g Enabled by EMC Celerra NS-120 using DNFS EMC Backup and Recovery for Oracle Database 11g Enabled by EMC Celerra NS-120 using DNFS Abstract This white paper examines the performance considerations of placing Oracle Databases on Enterprise Flash

More information

Overview of HP tiered solutions program for Microsoft Exchange Server 2010

Overview of HP tiered solutions program for Microsoft Exchange Server 2010 Overview of HP tiered solutions program for Microsoft Exchange Server 2010 Table of contents Executive summary... 2 Introduction... 3 Exchange 2010 changes that impact tiered solutions... 3 Hardware platforms...

More information

EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts

EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts P/N 300 003 807, Revision A06 May 30, 2008 This document describes how to configure iscsi initiator ports and how to set up

More information

DELL EMC VMAX UNISPHERE 360

DELL EMC VMAX UNISPHERE 360 DELL EMC VMAX UNISPHERE 360 ABSTRACT Using Unisphere 360 to consolidate the management of VMAX storage system offers many benefits. This management interface offers a single interface where all enrolled

More information

CA Unified Infrastructure Management

CA Unified Infrastructure Management CA Unified Infrastructure Management clariion Release Notes All series Copyright Notice This online help system (the "System") is for your informational purposes only and is subject to change or withdrawal

More information

EMC Storage for VMware vsphere Enabled by EMC VPLEX Local

EMC Storage for VMware vsphere Enabled by EMC VPLEX Local EMC Storage for VMware vsphere Enabled by EMC VPLEX Local and VMware vsphere 4.1 EMC Information Infrastructure Solutions Abstract Storage migration and array replacement are costly, time-consuming projects

More information

Release Notes P/N REV A01 February 23, 2006

Release Notes P/N REV A01 February 23, 2006 EMC AX-Series Navisphere SP Agent Version 6.20.0.3.12 for FLARE OE 02.20.yyy Release Notes P/N 300-003-516 REV A01 February 23, 2006 These release notes contain supplemental information about EMC Navisphere

More information

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE White Paper EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE EMC XtremSF, EMC XtremCache, EMC Symmetrix VMAX and Symmetrix VMAX 10K, XtremSF and XtremCache dramatically improve Oracle performance Symmetrix

More information

DELL TM AX4-5 Application Performance

DELL TM AX4-5 Application Performance DELL TM AX4-5 Application Performance A Comparison of Entry-level Storage Platforms Abstract This paper compares the performance of the Dell AX4-5 with the performance of similarly configured IBM DS3400

More information

EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005

EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005 EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005 Best Practices Planning Abstract This technical white paper explains best practices associated with Microsoft SQL Server 2000

More information

EMC Solutions for Backup to Disk EMC Celerra LAN Backup to Disk with IBM Tivoli Storage Manager Best Practices Planning

EMC Solutions for Backup to Disk EMC Celerra LAN Backup to Disk with IBM Tivoli Storage Manager Best Practices Planning EMC Solutions for Backup to Disk EMC Celerra LAN Backup to Disk with IBM Tivoli Storage Manager Best Practices Planning Abstract This white paper describes how to configure the Celerra IP storage system

More information

VMware with CLARiiON. Sheetal Kochavara

VMware with CLARiiON. Sheetal Kochavara VMware with CLARiiON Sheetal Kochavara Agenda Overview of CLARiiON hardware and software products Integration of CLARiiON with VMware Use Cases of CLARiiON replication software with VMware EMC CLARiiON

More information

SANmelody TRIAL Quick Start Guide

SANmelody TRIAL Quick Start Guide Page 1 SANmelody TRIAL Quick Start Guide From Installation to Presenting Virtual Storage Download the trial software at: SANmelody Trial Software SANmelody TRIAL Quick Start Guide Change Summary August,

More information

Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems

Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems Lenovo SAN Manager Rapid Tier and Read Cache June 2017 David Vestal, WW Product Marketing Lenovo.com/systems Table of Contents Introduction... 3 Automated Sub-LUN Tiering... 4 LUN-level tiering is inflexible

More information

VMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY

VMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY VMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY HYPERMAX OS Integration with CloudArray ABSTRACT With organizations around the world facing compliance regulations, an increase in data, and a decrease in IT spending,

More information

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi Evaluation report prepared under contract with Intel Corporation Introduction As the interest in converged networks grows, and as the vendors

More information

EMC VMAX UNISPHERE 360

EMC VMAX UNISPHERE 360 EMC VMAX UNISPHERE 360 ABSTRACT Unisphere 360 is a new application designed to consolidate and simplify data center management of VMAX Storage systems. WHITE PAPER To learn more about how EMC products,

More information