Wonderware FactorySuite A 2

Size: px
Start display at page:

Download "Wonderware FactorySuite A 2"

Transcription

1 Wonderware FactorySuite A 2 Deployment Guide Revision D.2 Last Revision: 1/27/06 Invensys Systems, Inc.

2 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Invensys Systems, Inc. No copyright or patent liability is assumed with respect to the use of the information contained herein. Although every precaution has been taken in the preparation of this documentation, the publisher and the author assume no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. The information in this documentation is subject to change without notice and does not represent a commitment on the part of Invensys Systems, Inc. The software described in this documentation is furnished under a license or nondisclosure agreement. This software may be used or copied only in accordance with the terms of these agreements Invensys Systems, Inc. All Rights Reserved. Trademarks All terms mentioned in this documentation that are known to be trademarks or service marks have been appropriately capitalized. Invensys Systems, Inc. cannot attest to the accuracy of this information. Use of a term in this documentation should not be regarded as affecting the validity of any trademark or service mark. Alarm Logger, ActiveFactory, ArchestrA, Avantis, DBDump, DBLoad, DT Analyst, FactoryFocus, FactoryOffice, FactorySuite, FactorySuite A 2, InBatch, InControl, IndustrialRAD, IndustrialSQL Server, InTouch, InTrack, MaintenanceSuite, MuniSuite, QI Analyst, SCADAlarm, SCADASuite, SuiteLink, SuiteVoyager, WindowMaker, WindowViewer, Wonderware, and Wonderware Logger are trademarks of Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners.

3 Contents 3 Contents Before You Begin...11 About This Document...11 Assumptions...11 FactorySuite A2 Application Versions FactorySuite A2 Terminology Document Conventions Where to Find Additional Information ArchestrA Community Website Technical Support CHAPTER 1: Planning the Integration Project...17 FactorySuite A2 Project Workflow FactorySuite A2 Workflow Summary Identify Field Devices and Functional Requirements Define Object Naming Conventions Define the Area Model Plan Templates Define the Security Model Define the Deployment Model Document the Planning Results CHAPTER 2: Identifying Topology Requirements...29 Topology Component Distribution Galaxy Repository (Configuration Database) AutomationObject Server Node Visualization Node I/O Server Node Engineering Station Node Historian Node SuiteVoyager Portal Topology Categories Distributed Local Network Client/Server General Topology Planning Considerations Legacy InTouch Software Applications Terminal Services Widely-Distributed Network Best Practices for Topology Configuration Network Configuration Software Configuration... 53

4 4 Contents I/O Server Connectivity...54 I/O and DAServers: Best Practice...54 DIObject Advantages...55 Extending the IAS Environment...56 CHAPTER 3: Implementing Redundancy...61 Redundant System Requirements...62 AppEngine Redundancy States...63 NIC Configuration: Redundant Message Channel (RMC)...63 Primary Network Connection...64 RMC Network Connection...64 Redundant DIObjects...65 Configuration...65 Redundant Configuration Combinations...67 Dedicated Standby Server - No Redundant I/O Server...67 Load Sharing Configurations...68 Run-Time Considerations...73 Deployment Considerations...74 Scripting Considerations...75 History...77 Alarms in a Redundant Configuration...78 Redundant Configuration with Dedicated Visualization Nodes...79 Redundant Pair with No Dedicated Visualization Client Nodes...79 Failover Causes in Redundant AppEngines...80 Forcing Failover...80 Communication Failure in the Supervisory (Primary) Network...80 RMC Communication Failure...83 PC Failures...83 Redundant System Checklist...85 Tuning Recommendations for Redundancy in Large Systems...86 Tuning Redundant Engine Attributes...87 Engine Monitoring...88 CHAPTER 4: Integrating FactorySuite Applications...91 IndustrialSQL Server Historian...92 ActiveFactory Software...92 ActiveFactory Reporting Website...92 InTouch HMI Software...93 WindowMaker, WindowViewer, and View...93 InTouch SmartSymbols...93 Network Utilization...94 InTouch Software Add-Ins...95 Tablet and Panel PCs...96 SCADAlarm Event Notification Software...97

5 Contents 5 Alarm DB Manager SuiteVoyager Software QI Analyst Software DT Analyst Software InTrack Software Using InTrack Software with an Application Server InTrack Software Integration with Other FactorySuite Software InBatch Software InBatch Production System Requirements InBatch Production System Topologies Third Party Application Integration FactorySuite Gateway Other Connectivity/Integration Tools CHAPTER 5: Working with Templates Before Creating Templates Creating a Template Model Containment vs. UDAs Base Template Functional Summary Template Modeling Examples Using UDAs and Extensions Deriving Templates and Instances Re-Using Templates in Different Galaxies Export/Import Templates and Instances Export Automation Objects Galaxy Dump Scripting at the Template Level Script Execution Types Scoping Variables Scripting for OLE and/or COM Objects Using Aliases Determining Object and Script Execution Order Asynchronous Scripts Scripting I/O References Writing to a Database CHAPTER 6: Implementing QuickScript.NET IAS Scripting Architecture ApplicationObject Script Interactions Script Access to IAS Object Attributes Referencing Object Attribute and Property Values Other Script Function Categories Using UDAs

6 6 Contents Inter- and Intra-Object Scripting Considerations Evolving from InTouch to ArchestrA Inter-Object Scripting Interactions Intra-Object Scripting Interactions Remote References to Live Data Indirect Referencing IAS Context Accessing the.net Framework NET Overview System.Data Classes (Connection to MSSQL via ADO.NET) Scripting Practices Using.NET for Database Access Defining Project Scope and Requirements Using "Shape" Template Objects Using the ObjectCacheExt (Function Library) Posting the Data Object Functional Encapsulations Scripting Database Access ObjectCacheExt.DLL Overview Purpose of ObjectCacheExt.DLL Template Object Examples Example Object Interactions via UDAs $SqlConnCacheMgr Script Examples $PostToDBaORb Template Object $PostTOaORb Derived From $PostToDBaORb Time-Based Calculations and Retentive Values Documenting Your Classes Summary CHAPTER 7: Architecting Security Wonderware Security Perspective Common Control System Security Considerations Common Security Evaluation Topics About Security Infrastructure Components Securing FactorySuite A2 Systems Security Considerations Corporate Network Infrastructure Layer Process Control Network (PCN) Layer Securing Visualization OS Group Based Security Mode Notes Securing the Configuration Environment Distributed COM (DCOM) Limiting the DCOM Port Range Security Recommendations Summary...208

7 Contents 7 CHAPTER 8: Historizing Data General Considerations Data Point Volumes Data Storage Rate Data Loss Prevention Area and Data Storage Relocation Non-Historian Data Storage Considerations CHAPTER 9: Implementing Alarms and Events General Considerations Configuring Alarm Queries Determining the Alarm Topology Alarming in a Distributed Local Network Topology Alarming in a Client/Server Topology Logging Historical Alarms CHAPTER 10: Assessing System Size and Performance System Disk Space and RAM Use Galaxy Repository Performance Considerations Predicting Disk Space and RAM Requirements at Configuration Time Predicting Disk Space and RAM Requirements at Run-Time Predicting System Performance Unit Application Definition Hardware Specifications Baseline Server CPU Values Performance Data Single Node System Implementation Large Distributed FactorySuite A2 System Topology Very Large Distributed FactorySuite A2 System Topology Failover Performance Dedicated Standby Configuration Load Shared with Remote I/O Data Source DIObject Performance Notes OPC Client Performance

8 8 Contents Chapter 11: Working in Wide-Area Networks and SCADA Systems Wide-Area Networks Overview Network Terminology Network and Operating System Configuration Minimum Bandwidth Requirements Subnets DCOM Domain Controller Remote Access Services (RAS) Terminal Services Security Domain-Level Security Workgroup-Level Security Application Configuration Overview Acquire and Store Timestamps for Event Data Acquire and Store RTU Event Information Disaster Recovery Industrial Application Server (Distributed IDE) Platform and Engine Tuning Tuning the Historian Primitive/MDAS (in Platforms and Engines) Alarms Inter-Node Communications Distributing InTouch HMI Nodes Using IndustrialSQL Server Historian Diagnostics SCADA Benchmarks MX Subscriptions Network Utilization Alarm Network Utilization History Network Utilization Summary Network Utilization Network Utilization at Deployment Chapter 12: Maintaining the System FactorySuite A2 System Diagnostic/Maintenance Tools Object Viewer System Management Console (SMC) Add-on Diagnostic/Maintenance Tools Galaxy Diagnostic Tools Galaxy Maintenance Tools OS Diagnostic Tools Performance Monitor Event Viewer...279

9 Contents 9 APPENDIX A: System Integrator Checklist..281 General Use Time Synchronization Disable Hyper-Threading Communication Configure IP Addressing Configure Dual NICs Security Confirm User Name and Password Configure Anti-Virus Software Administration (Local and Remote) Install Correct IAS Components Connection Requirements for Remote IDE (from a Client Machine to a Galaxy) Redundancy Configuration Redundant AppEngines Multiple NICs Migration Verify Version and Patches Upgrade Correctly Compatibility FactorySuite Component Version Compatibility APPENDIX B:.NET Example Source Code..287 SqlConnCacheMgr Object SqlConnCacheMgr Overview SqlConnCacheMgr Configuration PostTOaORb Object PostTOaORb Overview Template Object:$PostTOaORb RunTime Object RunTime Overview RunTime Run-Time Behavior RunTime Configuration Template Object:$RunTime $RunTime - Start ObjectCache.dll Visual Studio.NET C# Solution Debugging the Project ObjectCacheExt.DLL Source Code Index...387

10 10 Contents

11 Before You Begin 11 Before You Begin About This Document The FactorySuite A2 Deployment Guide provides recommendations and "best practice" information to help define, design and implement integration projects within the Wonderware FactorySuite A2 System environment. Recommendations included in this guide are based on experience gained from multiple projects using the ArchestrA infrastructure for FactorySuite A2. Recommendations contained in this document should not preclude discovering other methods and procedures that work effectively. Assumptions This deployment guide is intended for: Engineers and other technical personnel who will be developing and implementing FactorySuite A2 System solutions. Sales personnel or Sales Engineers who need to define system topologies in order to submit FactorySuite A2 System project proposals. It is assumed that you are familiar with the working environment of the Microsoft Windows 2000 Server, Windows Server 2003, and Windows XP Professional operating systems, as well as with a scripting, programming, or macro language. Also, an understanding of concepts such as variables, statements, functions, and methods will help you to achieve best results. It is assumed that you are familiar with the individual components that constitute the FactorySuite A2 environment. For additional information about a component, see the associated user documentation. All topologies referenced in this Deployment Guide assume a "Bus" topology, which comprises a single main communications line (trunk) to which nodes are attached; also known as Linear Bus. Exceptions are noted. For more information on standard topology schemas, see mspx or

12 12 Before You Begin FactorySuite A2 Application Versions This Deployment Guide has been updated to include current Wonderware software product versions (current Service Packs are assumed for all software). However, the information is designed to apply to previous versions except where noted. The current versions are: Wonderware Industrial Application Server 2.1 IndustrialSQL Server Historian 9.0 InTouch HMI 9.5 Active Factory Software 9.1 SCADAlarm Event Notification Software 6.0 SP1 SuiteVoyager Software 2.5 QI Analyst Software 4.2 DT Analyst Software 2.2 InTrack Software 7.1 InBatch Software 8.0 (FlexFormula and Premier 8.1) Production Event Module (PEM) 1.0 InControl Software 7.11 Third Party and Wonderware SDK Applications as noted. The figure on the following page contains terms used throughout this document. Definitions of specific terms are included after the figure.

13 Before You Begin 13 FactorySuite A 2 Terminology The following figure shows basic object classifications and their relationships within the IAS System. This document focuses on the Application/Device Integration/Engine/Platform/Area Objects level except where otherwise noted: Galaxy Objects AutomationObjects Domain Objects System Objects Application Objects Device Integration Objects (DIObjects) EngineObjects PlatformObjects AreaObjects AnalogDevice FS Gateway AppEngine WinPlatform Area DiscreteDevice AB TCP Network Field Reference AB PLC5 Switch Etc. User-Defined The following terms are used throughout this document: Area: The AutomationObject that represents an Area of a plant within a Galaxy. The Area object acts as an alarm concentrator and is used to put other AutomationObjects into the context of the actual physical automation layout. ApplicationEngine (AppEngine): A real-time Engine that hosts and executes AutomationObjects. ApplicationObject: An AutomationObject that represents some element of a user application. This may include elements such as (but not limited to) an automation process component (e.g. thermocouple, pump, motor, valve, reactor, tank, etc.) or associated application component (e.g. function block, PID loop, Sequential Function Chart, Ladder Logic program, batch phase, SPC data sheet, etc.). AutomationObject: An Object that represents hardware, software or Engines as objects with a user-defined, unique name within the Galaxy. It provides a standard way to create, name, download, execute or monitor the represented component. Device Integration Objects (DIObject): AutomationObjects that represent the communication with external devices, which all run on the Application Engine. For example:

14 14 Before You Begin DINetwork Object: Refers to the object that represents the network interface port to the device via the Data Access Server, providing diagnostics, and configuration for that specific card. DIDevice Object: Refers to the object that represents the actual external device (e.g. PLC, RTU) which is associated to the DINetwork Object. Providing the ability to diagnose, browse data registers, and DAGroups for that device. Platform Object: A representation of the physical hardware that the ArchestrA software is running on. Platform Objects host Engine Objects (see WinPlatform). WinPlatform: A single computer in a Galaxy consisting of Network Message Exchange, a set of basic services, the operating system and the physical hardware. This object hosts Engines and is a type of Platform Object. Document Conventions This documentation uses the following conventions: Convention Bold Monospace Italic Used for Menus, commands, buttons, icons, dialog boxes and dialog box options. Start menu selections, text you must type, and programming code. Options in text or programming code you must type. Where to Find Additional Information Wonderware offers a variety of support options to answer questions on Wonderware products and their implementation. ArchestrA Community Website For timely information about products and real-world scenarios, refer to the ArchestrA Community website: The ArchestrA Community website is an information center where users, systems integrators (SIs) and OEMs can share information and application stories, obtain products and learn about training opportunities. A key component of this website is the Application Object Warehouse, a constantly growing resource that provides downloadable ArchestrA objects, including a range of shareware products. In the future, objects from the Invensys-driven object library will be available for purchase. Third parties are also encouraged to submit their own ArchestrA objects for inclusion.

15 Before You Begin 15 Technical Support Before contacting Technical Support, please refer to the appropriate chapter(s) of this manual and to the User's Guide and Online Help for the relevant FactorySuite A2 System component(s). For local support in your language, please contact a Wonderware-certified support provider in your area or country. For a list of certified support providers, see Receive technical support by sending an to your local distributor or to support@wonderware.com. Online: You can access Wonderware Technical Support online at Telephone: Call Wonderware Technical Support at the following numbers: U.S. and Canada (toll-free): 800-WONDER1 ( ) 7 a.m. to 5 p.m. (Pacific Time) Outside the U.S. and Canada: (949) If you need to contact technical support for assistance, please have the following information available: The type and version of the operating system you are using. For example, Microsoft Windows XP Professional. The exact wording of the error messages encountered. Any relevant output listing from the Log Viewer or any other diagnostic applications. Details of the attempts you made to solve the problem(s) and your results. Details of how to reproduce the problem. If known, the Wonderware Technical Support case number assigned to your problem (if this is an ongoing problem). When requesting technical support, please include your first, last and company names, as well as the telephone number or address where you can be reached.

16 16 Before You Begin

17 Planning the Integration Project 17 CHAPTER 1 Planning the Integration Project The FactorySuite A2 System project begins with a thorough planning phase. This chapter explains the FactorySuite A2 project workflow. The workflow is designed to make engineering efforts more efficient by completing specific tasks in a logical and consistent (repeatable) sequence. Contents FactorySuite A2 Project Workflow

18 18 Chapter 1 FactorySuite A 2 Project Workflow The project information resulting from the planning phase becomes a roadmap (project template) when creating the FactorySuite A 2 System using the Integrated Development Environment (IDE). The more detailed the project plan, the less time it takes to create and implement the application, with fewer mistakes and rework. FactorySuite A2 Workflow Summary The following figure (workflow diagram) summarizes the sequential tasks necessary to successfully complete a FactorySuite A2 project: Identify Field Devices and Functional Requirements Define Naming Conventions Define the Area Model Plan Templates Define the Security Model Define the Deployment Model Each task is detailed on the following pages, and includes a checklist (summary) where applicable. Identify Field Devices and Functional Requirements The first project workflow task identifies field devices that are included in the system. Field devices include components such as valves, agitators, rakes, pumps, Proportional-Integral-Derivative (PID) controllers, totalizers, and so on. Some devices are made up of more base-level devices. For example, a motor is a device that may be part of an agitator or a pump. After identifying all field devices, determine the functionality for each.

19 Planning the Integration Project 19 Field Devices Checklist A. To identify field devices, refer to a Piping and Instrumentation Diagram (P&ID). This diagram shows all field devices and illustrates the flow between them. A good P&ID ensures the application planning process is faster and more efficient. Verify that the P&ID is correct and up-to-date before beginning the planning process. The following figure shows a simple P&ID: FIC 301 FV103 PT 301 FIC 402 TT 301 LIC 401 FV402 DRIVE 3 FT 302 LT 402 PT 401 CT 301 FV403 FT 401 FV401 DRIVE 4 CT 401 The key for this P&ID is as follows: FIC = Flow Controller PT = Pressure Transmitter TT = Temperature Transmitter FT = Flow Transmitter CT = Concentration Transmitter LT = Level Transmitter LIC = Level Controller FV = Flow Valve B. Examine each component in the P&ID and identify each basic device. For example, a simple valve can be a basic device. A motor, however, may be comprised of multiple basic devices.

20 20 Chapter 1 C. Once a complete list is created, group the devices according to type, such as by Valves, Pumps, and so on. Consolidate any duplicate devices into common types so that only a list of unique basic devices remains, and then document them in the project planning worksheet. Each basic device is represented in the IDE as an ApplicationObject. An instance of an object must be derived from a defined template. The number of device types in the final list will help determine how many object templates are necessary for your application. Group multiple basic objects to create more complex objects (containment). For more information on objects, templates, and containment, see the IDE documentation for the Industrial Application Server. Functional Requirements Checklist D. Define the functional requirements for each unique device. The functional requirements list includes: User Defined Attributes: Determine the types of attributes the object will have. Attributes are parameters of the object that can access data from other objects as well as provide access to their own data to other objects (inputs and outputs). Scripting: What scripts will be associated with the device? Specify scripts both for self-configuring the object as well as for run-time operation. Historization: Are there process values associated with this device that you want to historize? How often do you want to store the values? Do you want to add change limits for historization? Alarms and Events: Which attributes require alarms? What values do you want to be logged as events? Note The Industrial Application Server IDE's alarms and events provide similar functionality to what is provided within InTouch Software. Security: Which users will access to the device? What type of access is appropriate? For example, you may grant a group of operators readonly access for a device, but allow read-write access for an administrator. You can set up different security for each attribute of a device. All the above functional requirement areas are discussed in detail in this Deployment Guide.

21 Planning the Integration Project 21 Define Object Naming Conventions The second workflow task defines naming conventions for templates, objects, and object attributes. Naming conventions should adhere to: Conventions in use by the company. ArchestrA IDE naming restrictions. For information on allowed names and characters, see IDE documentation. The following (instance) tagname is used as an example: YY123XV456 It has the following attributes: OLS, CLS, Out, Auto, Man The following figure shows the diiffences between the HMI and ArchestrA naming conventions: HMIs YY123XV456\OLS YY123XV456\CLS ArchestrA.OLS.CLS YY123XV456\Out YY123XV456\Auto YY123XV456\Man YY123XV456.Out.Auto.Man Individual Tags Object Object Attributes Create references using the following IDE naming convention: <objectname>.<attributename> For example: YY123XV456.OLS

22 22 Chapter 1 Define the Area Model The third workflow task defines the Area model. An Area is a logical object group that represents a portion of the physical plant layout. For example, Receiving Area, Process Area, Packaging Area and Dispatch Areas are all logical representations of a physical plant area. Define and document all necessary Plant Areas to ensure each AutomationObject is assigned to its relevant Area. Note The default installation creates the Unassigned Area. All object instances will be assigned to this Area unless new areas are created. Area Model Checklist A. Create all Areas first. An object instance can then be easily assigned to the correct Area; otherwise, you will have to move them out of the Unassigned Area later. B. Create a System Area. Assign instances of WinPlatform and AppEngine objects to the System Area. WinPlatform and AppEngine objects are used to support communications for the application, and are not necessarily relevant to a plant-related Area. C. Group Alarms according to Areas. D. Areas can be nested. Sub-areas can be assigned to a different AppEngine on a different platform. E. When building an Area hierarchy, remember that the base Area (assigned to a Platform) determines how underlying objects are deployed. F. If a plant area (physical location) contains two computers running AutomationObject Server platforms, two logical Areas must be created for the single physical plant area. It may be practical to create an object instance for one Area at a time. If using this development approach, mark the Area as Default, so that each object instance is automatically assigned to the Default Area. Before creating instances in another Area, change the default setting to the new Area. G. Equate various Areas to Alarm Groups. Alarm displays can easily be filtered at the Area level. For more information on Areas, see the IDE documentation.

23 Planning the Integration Project 23 Plan Templates The fourth workflow task determines the necessary object "shape" templates. A Shape template is an object that contains common, configuration parameters for derived objects (objects used multiple times within a project). The Shape Template is derived from the $BaseTemplate object and is designed to represent baseline or "generic" physical objects, or to encapsulate specific, baseline functionality within the production environment. Both the Shape Templates and child Template instances are called ApplicationObjects. For example, multiple instances of a certain valve type may exist within the production environment. Create a Shape valve template that includes the required, basic, valve properties. The Shape Template can now be reused multiple times, either as another template or an object instance. If changes are necessary, they are propagated to the derived object instances. Use the drag-and-drop operation within the IDE to create object instances. The following figure shows multiple instances (Valve001, -002, etc.) derived from a single object template ($Valve): Note For a practical example of a Shape Template, see "Using "Shape" Template Objects" on page 148. Industrial Application Server is shipped with a number of pre-defined base templates to help you create your application quickly and easily. The base templates provided with Industrial Application Server are summarized in "Base Template Functional Summary" on page 112. Determine if any of their functionally match the requirements of the devices on your list. If the base templates do not satisfy the design requirements, create (derive) new shape templates or object instances from the $UserDefined object base template.

24 24 Chapter 1 Application Objects $AnalogDevice $DiscreteDevice $FieldReference $UserDefined $Valve Base Templates Derived Template A child template derived from a base (parent) template can be highly customized. Implement user-defined attributes (UDAs), scripting, and alarm and history extensions. Note Use the Galaxy Dump and Load Utility to create a.csv file, which can then be modified using a text editor. Then load the.csv file back into the Galaxy Repository. This enables quick and easy bulk configuration edits. Template Derivation Since templates can be derived from other templates, and child templates can inherit properties of the parents, establish a template hierarchy that defines what is needed before creating other object templates or instances. Always begin with the most basic template for a type of object, then derive more complicated objects. If applicable, lock object attributes at the template level, so that changes cannot be made to those same attributes for any derived objects. A production facility typically uses many different device models from different manufacturers. For example, a process production environment has a number of flow meters in a facility. A base flow meter template would contain those fields, settings, and so on, that are common to all models used within the facility. Derive a new template from the base flow meter template for each manufacturer. The derived template for the specific manufacturer includes additional attributes specific to the manufacturer. A new set of templates would then be derived from the manufacturer-specific template to define specific models of flow meters. Finally, instances would be created from the model-specific template. Note For detailed examples of template derivation, see Chapter 5, "Working with Templates." For more information on templates, template derivation, and locking, see the IDE documentation. Template Containment Template containment allows more advanced structures to be modeled as a single object. For example, a new template called "Tank" is derived from the $UserDefined base or shape template. Use the instance to contain other ApplicationObjects that represent aspects of the tank, such as pumps, valves, and levels.

25 Planning the Integration Project 25 Then, derive two $DiscreteDevice template instances called "Inlet" and "Outlet," and configure them as valves. Derive an AnalogDevice template instance called "Level," and contain them within the Tank template. The containment hierarchy is as follows: $Tank $V101[ Inlet ] $V102[ Outlet ] $LT102[ Level ] Template containment Note Deeply nested template/container structures can slow the check-in of changes in IDE development and propagation. Two options are available when defining object properties: Use template containment to create a higher-level object with lower-level objects. This practice works best when the lower-level object also has many components to it and may contain even lower-level objects. However, when adding the lowest-level object to a template, it is possible to use either template containment or user-defined attributes. Both allow for an external I/O point link and historization. If required attributes (such as complex alarms, setpoints, or other features) are readily available in a template, use template containment. If the lowerlevel object is very basic, use a UDA (User-Defined Attribute). It is always valid to use a contained object, even if it is a simple property. Always use a contained object for I/O points and use a user-defined attribute for memory or calculated values. How this is accomplished is up to the application designer, and should be decided in advance for project consistency. Object Template Checklist A. Document which existing templates can be used for which objects, and which templates are created from scratch. For information on a particular object template, see the Help file for that object. B. Design your containment model at the template level before generating large object instance quantities. C. Create instances from the top "container" template of a hierarchical set of contained templates. Such template hierarchies should be tested with one or two instances before proceeding to the generation of numerous instances. Any change by insertion or removal of a contained template in the hierarchy does not result in propagation of new insertions or removals in the instance hierarchies. For instances of the containment hierarchy, insertions and removals must be managed individually. However, changes within already included contained templates can be automatically propagated by locking.

26 26 Chapter 1 Note For detailed information on working with templates, see Chapter 5, "Working with Templates." Define the Security Model The fifth workflow task defines the security model. The following basic concepts are reviewed in order to reinforce understanding of the ArchestrA security model: Users: A user is each individual person that will be using the system. For example, John Smith and Peter Perez. Roles: Roles define groups of users within the security system. Roles usually reflect the type of work performed by different groups within the factory environment. For example, Operators and Technicians. Permissions: Permissions determine what users are allowed to do within the system. For example: Operate, Tune, and Configure. Security Groups: A security group is a group of objects with the same security characteristics. The purpose of a security group is to simplify object security management by avoiding the need to assign security permission for each role to each individual object. Security groups typically map to Areas and reflect a physical location of your plant, but each area will have more than one security groups if multiple levels of security is required within the area. For example, it may be necessary to assign specific Technicians to the Line_1 security group, but not to the Line_2 security group. Security Model Checklist A. Define Users, Roles, Permissions, and Security Groups necessary to implement security for the factory environment. Select Users and Roles previously defined within the Operating System Security model, or define them within the IDE. A combination of both security types is also possible. Using Operating System users and Roles facilitates object deployment and makes future maintenance easier. B. Determine security settings for writable attributes of objects. The security options for writeable attributes consists of: Read Only, Operate, Tune, Secured Write, Verified Write, and Configure. Review the functional worksheet that lists the objects (and their attributes). Security permissions reflect the users' rights to change the attribute value. An Operate permission requirement does not mean that the user must be an Operator. A QA inspector might have Operate permissions to change a value on an object that that collects QA data, while an operator on the same production line does not have this permission.

27 Planning the Integration Project 27 To set up Security using the IDE 1. Configure the attribute security for Template objects (at the Template level). 2. Create security groups. 3. Create roles and assign them to security groups. 4. Select permissions and grant them to roles. 5. Define users and assign them to roles. For more information on security configuration, see the IDE documentation. Note For detailed information about FactorySuite A2 Security, see Chapter 7, "Architecting Security." Define the Deployment Model The last workflow task defines the deployment model that specifies where objects are deployed. In other words, the deployment model defines which nodes will host the various AutomationObjects. Each computer in the FactorySuite A2 System network must have a Platform object, AppEngine object, and Area object deployed to it. For example, KT101, LT 101 and MK101 are all areas in the following figure: MyGalaxy Unassigned Host MMark08 MMark13 AppEngine001 KT101 [ KT101 ] LT101 [ LT101 ] MK101 [ MK101 ] LT112HT239 LT112P200 LT112PT221 LT112PT223 The objects deployed on particular platforms and engines define the objects' "load" on the platform. The load is based on the number of I/O points, the number of user-defined attributes (UDAs), etc. The more complex the object, the higher the load required to run it. Note For object types and target deployment node recommendations (such as DIObjects), see Chapter 10, "Assessing System Size and Performance." After deployment, use the Object Viewer to check communications between nodes and determine if the system is running optimally. For example, a node may be executing more objects than it can easily handle, and it will be necessary to deploy one or more objects to another computer.

28 28 Chapter 1 Note For more information on deployment, see IDE documentation. Document the Planning Results Determine how to document the project planning results before beginning the planning phase. Use Microsoft Excel (or other spreadsheet application) to document the list of devices, the functionality of each device, process areas to which the devices belong, etc. For example:

29 Identifying Topology Requirements 29 CHAPTER 2 Identifying Topology Requirements System and information requirements are unique to each manufacturing domain. To control equipment, computers must provide real-time response to interrupts. To plan production, scheduling systems must consider sales commitments, routing costs, equipment downtime, and numerous other variables. Enterprise system and information requirements are satisfied by architecting effective network topologies and implementing software to leverage the topology. This chapter describes common FactorySuite A 2 System topologies. They include application components such as Industrial Application Server, IndustrialSQL Server Historian, InTouch HMI software, and Wonderware I/O Servers, OLE for Process Control (OPC) Servers, and Data Access Servers (DAServers). The topology configurations include descriptions and "best practice" recommendations for specific components and functionality. Note For updated information on system requirements, see the user guides or readme files in the installation directory of the appropriate product CD. Pay particular attention to the requirements regarding the version and Service Pack level of the operating system and other application components. Contents Topology Component Distribution Topology Categories General Topology Planning Considerations Best Practices for Topology Configuration I/O Server Connectivity Extending the IAS Environment

30 30 Chapter 2 Topology Component Distribution A Galaxy encompasses the whole supervisory control system, which is represented by a single logical namespace and a collection of Platforms, AppEngines, and objects. The Galaxy defines the namespace in which all components and objects reside. Because of its distributed nature and common services, Industrial Application Server does not require expensive server-class or fault-tolerant computers to enable a robust industrial application. The Industrial Application Server distributes objects throughout a distributed (networked) environment, allowing a single application to be split into a number of different component objects, each of which can run on a different computer. Before exploring the following FactorySuite A 2 System topologies, review the main components and how they will be distributed based on requirements and functionality. The main topology components are: Galaxy Repository (Configuration Database) AutomationObject Server Node (AOS) Visualization Node I/O Server Node Engineering Station Node Historian Node SuiteVoyager Portal The following figure identifies each topology component: Visualization Node Visualization Node Visualization Node Supervisory Network Network Device (Switch or Router ) AutomationObject Server Historian ( Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network

31 Identifying Topology Requirements 31 Galaxy Repository (Configuration Database) The Galaxy Repository (also called Configuration Database or "GR") can be installed on a dedicated node or on the Engineering Station. Note The following topology figures show the Galaxy Repository as the Configuration Database on the Engineering Node. The Galaxy Repository manages the configuration data associated with one or more Galaxies. This data is stored in individual databases, one for each Galaxy in the system. Microsoft SQL Server 2000 (Standard Edition) is the relational database used to store the data. Note Install the Galaxy Repository on the same AOS node only when using a single node. For information on installing the GR on the same node with any other components, see "Single Node System Implementation" on page 234. During run-time, the GR communicates with all nodes in the Galaxy to keep them updated on global changes such as security model modifications, etc. Even though it is possible to disconnect the GR from the Galaxy and still keep remaining nodes in production, it is recommended to maintain the GR connection to the Galaxy in order to transfer all global changes when they occur. The Galaxy Repository is accessed when the objects in the database are viewed, created, modified, deleted, deployed, or uploaded. The Galaxy Repository is also accessed when a running object attempts to access another object that has not been previously referenced. Best Practice If working in a distributed network context (wide-area networks, distributed SCADA systems characterized by slow connections), install the Galaxy Repository on a laptop computer and carry it to remote sites as a portable resource for application maintenance. Connect the portable configuration database node to the local node via a dedicated local area network (LAN) connection to expedite the process of deploying/undeploying objects and creating and configuring templates. Remember that if the Galaxy Repository is not available on the network, existing objects cannot be deployed or undeployed to/from any Platform. However, any deployed objects will continue to operate normally. Create a ghost image of the portable GR Node, and perform frequent backups in case the laptop is damaged or lost.

32 32 Chapter 2 Configuration and run-time components for the Configuration Database node are described in the following table: Configuration Components Integrated Development Environment (IDE) Galaxy Repository* Microsoft SQL Server 2000* Run-Time Components Bootstrap* Platform* * Required component AutomationObject Server Node The AutomationObject Server node provides the processing resources for AppEngines, Areas, Application Objects, and DeviceIntegration (DI) Objects. The AutomationObject Server node requires a Platform to be deployed. The AutomationObject Server node functionality can be combined with a visualization node, depending on the process requirements and system capabilities. A distributed local network topology takes advantage of this type of configuration to provide flexibility to the system. Configuration and run-time components for the AutomationObject Server node are described in the following table: Configuration Components Integrated Development Environment (IDE) Run-Time Components Bootstrap* Platform* AppEngine* Areas ApplicationObjects DIObjects * Required component

33 Identifying Topology Requirements 33 Visualization Node A Visualization node is a computer running InTouch Software on top of a Platform. The Platform provides for communication with any other Galaxy component via the Message Exchange (MX) protocol. Configuration and run-time components for the Visualization node are described in the following table: Configuration Components (none) Run-Time Components Bootstrap* Platform* InTouch Software 8.0 or later; OR InTouch View 8.0 or higher* * Required component I/O Server Node An I/O Server node functions as the data source for the Industrial Application Server system. I/O Servers communicate with external devices. Supported communication protocols: Dynamic Data Exchange (DDE), SuiteLink, and OPC. Note An I/O Server node can also be an AutomationObject Server, depending on the available memory and CPU resources. DIObjects on the Industrial Application Server side manage the communication between AutomationObjects and the I/O Servers. DIObjects provide connectivity to I/O data sources, and represent the corresponding server(s) as part of the plant model in the AutomationServer environment. In the case of DAServers, the corresponding DIObjects are so closely related that redeploying a DIObject to a different node uninstalls the DAServer locally and reinstalls it in the target machine. DIObjects require a Platform and an AppEngine. These objects can reside either on the I/O Server node or on any AutomationObject Server node in the Galaxy. Configuration and run-time components for the I/O Server node are described in the following table: Configuration Components I/O Server* Run-Time Components Bootstrap Platform InTouch Software 8.0 or higher or InTouch View 8.0 or higher I/O Server* * Required component

34 34 Chapter 2 Best Practice Observe the following guidelines to optimize I/O data transmission: Always deploy the DIObject to the same node where the I/O data source is located, regardless of the protocol used by the I/O data source (DDE, Suitelink, OPC). If the I/O data source is on a node that is remote to the AutomationObject Server, the communication between the nodes is highly optimized by the MX (Message Exchange) protocol. A particular benefit is gained with this configuration when using OPC servers in remote nodes, since the system uses the MX protocol instead of DCOM communication between nodes. If the I/O data source is located in the same node as the AutomationObject Server, the communication is local, minimizing the travel time of data through the system. Note I/O Server installation sequence is important: Always install the most recent software last. For example: first I/O Servers, then DAServers, then the Bootstrap, and so on. Engineering Station Node All of the recommended topologies include a dedicated Engineering Station node for maintenance purposes. The Engineering Station node contains a FactorySuite Development package which consists of components such as the Integrated Development Environment (IDE) and InTouch WindowMaker. The GR (Galaxy Repository) could also reside on this node. Thus, you could implement any required changes in the system from the Engineering Station node using the IDE, which would then access the local configuration database. This configuration provides flexibility in maintaining remote sites, since you can use a laptop computer as the Engineering Station containing the configuration database node and gain access to the AutomationObject Server node via a LAN connection. With the IDE and the Galaxy Repository on the same node, if you need to deploy or undeploy large applications, network traffic in the Galaxy would not be affected by the IDE accessing the configuration data in a remote node. Configuration and run-time components for the Engineering Station node are described in the following table: Configuration Components Integrated Development Environment (IDE) InTouch WindowMaker 8.0 or higher Run-Time Components Bootstrap* Platform * Required component The IDE does not require a Platform. However, if Object Viewer is used on an Engineering Station node, a Platform is required. For more information about Object Viewer, see the Object Viewer documentation.

35 Identifying Topology Requirements 35 Best Practice When remote off-site access to the Galaxy Repository is required by means of the IDE, use a Terminal Service session or Remote Desktop connection to the Galaxy repository where the IDE has also been installed. Important! In order to launch an IDE session, the session must have user accounts in the Administrators group of the Terminal Server node. For more information about integrating InTouch Software for Terminal Services with other FactorySuite A 2 System components, see the Terminal Services for InTouch Deployment Guide. The Engineering Station node also hosts the development tools to modify InTouch Software applications using WindowMaker. Historian Node The Historian node is used to run IndustrialSQL Server Historian software. IndustrialSQL Server Historian stores all historical process data and provides real-time data to FactorySuite client applications such as ActiveFactory and SuiteVoyager Software. The Historian Node does not require a Platform. The AutomationObject Server pushes data (configured for historization) to the Historian node using the Manual Data Acquisition Service (MDAS) packaged with Industrial Application Server and IndustrialSQL Server Historian. Important! MDAS uses DCOM to send data to IndustrialSQL Server Historian. Ensure that DCOM is enabled (not blocked) and that TCP/UDP port 135 is accessible on both the AppServer and IndustrialSQL Server Historian nodes. The port may not be accessible if DCOM has been disabled on either of the computers or if there is a router between the two computers - the router may block the port. Configuration and run-time components for the Historian Node are included in the following table: Configuration Components * Required component Best Practice Run-Time Components Microsoft SQL Server 2000* IndustrialSQL Server Historian* Most system topologies combine the Historical and Alarm databases on the Historian Node. Configure the alarm system using the Alarm Logger utility, which creates the appropriate database and tables in Microsoft SQL Server. For requirements and recommendations for alarm configuration, see Chapter 9, "Implementing Alarms and Events." For information about historization, see Chapter 8, "Historizing Data."

36 36 Chapter 2 SuiteVoyager Portal A Server machine with a SuiteVoyager Software portal can be incorporated into any Galaxy. Use the Win-XML Exporter to convert InTouch windows to XML format, so SuiteVoyager Software clients can access real-time data from the Galaxy. A Platform must be deployed on the SuiteVoyager Portal for SuiteVoyager Software to access the Galaxy. Configuration and run-time components for the SuiteVoyager Portal are described in the following table: Configuration Components SuiteVoyager Software 2.0 SP1 or higher* Run-Time Components Bootstrap* Platform* SuiteVoyager Software 2.0 SP1 or higher* * Required component For information on deployment options for SuiteVoyager Software, see the SuiteVoyager Software documentation.

37 Identifying Topology Requirements 37 Topology Categories The following information describes high-level topology categories using FactorySuite A2 System components. Distributed Local Network This topology is designed for medium-sized systems where the processing requirements of each software component can be easily handled by the nodes providing the projected performance support. The primary characteristic of this topology type is that Visualization and AutomationObject Server functionalities coexist in the same node, called a Workstation. Several Workstation nodes (defined below) share data and run multiple functional components on each node. Different Workstation nodes coexist on a locally distributed network. The following Workstation characteristics are assumed unless otherwise noted: Workstation Node The Visualization and AutomationObject Server components are combined on the same node. Both components share the Platform, which handles communication with other nodes in the Galaxy. The Platform also allows for deployment/undeployment of ApplicationObjects. If you plan to combine the Visualization and AutomationServer components on the same node, evaluate the resource requirements for the following: Active tags-per-window. ActiveX controls displayed. Alarm displays. Trending. These values will impact AutomationObject service performance. Note For details on Alarm System configuration, see Chapter 9, "Implementing Alarms and Events." The relationship between "standalone" Workstations on a distributed local network is also known as "Peer-to-Peer."

38 38 Chapter 2 The following figure illustrates the software components and their distribution: Supervisory Network Workstation Historian ( Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server Network Device (Switch or Router ) PLC Network Client operating systems such as Windows XP Professional can manage up to 10 simultaneous active connections with other nodes. If the system is larger than 10 nodes, Windows Server 2003 must be used for all nodes. For additional information, see the General Topology Planning Considerations section later in this chapter. I/O Server Node(s) Different I/O data sources have different requirements. Two main groups are identified: Legacy I/O Server applications (SuiteLink, DDE, and OPC Servers) do not require a platform on the node on which they run. They can reside on either a standalone or workstation node. However, the DIObjects used to communicate with those data sources such as the DDESuiteLinkClient object, OPCClient object, and InTouchProxy objects must be deployed to an AppEngine on a Platform. Although it is not required that these DIObjects be installed on the same node as the data server(s) they communicate with, it is highly recommended in order to optimize communication throughput. For Device Integration objects like ABCIP and ABTCP DINetwork objects, both the DAServer and the corresponding DIObjects must reside on the same computer hosting an AppEngine. Best Practice I/O Servers can run on Workstations, provided the requirements for visualization processing, data processing, and I/O read-writes can be easily handled by the computer. Run the I/O Server and the corresponding DIObject on the same node where most or all of the object instances (that obtain data from that DIObject) are deployed. This implementation expedites the data transfer between the two components (the I/O Server and the object instance), since they both reside on the same node. This implementation also minimizes network traffic and increases reliability.

39 Identifying Topology Requirements 39 However, it is good practice to evaluate the overhead necessary to run each component. The following figure illustrates implementing I/O Servers on the same node: Supervisory Network Network Device (Switch or Router ) Workstation I/O Server Historian (Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal PLC Network Historian Node The IndustrialSQL Server Historian software must run on a designated node. Engineering Station and GR (Configuration Database) The Engineering Station node hosts the IDE and InTouch WindowMaker to facilitate Industrial Application Server and InTouch Software application maintenance. As the GR node, it hosts the SQL Server database that stores the Galaxy's Configuration Data. SuiteVoyager Portal The SuiteVoyager Portal supplies real-time historical data to web clients.

40 40 Chapter 2 Client/Server This topology configuration includes dedicated nodes running AutomationObject Servers, while visualization tasks are performed on separate nodes. The benefits of this topology include usability, flexibility, scalability, system reliability, and ease of system maintenance, since all configuration data resides on dedicated servers. The client components (represented by the visualization nodes) provide the means to operate the process using applications that provide data updates to process graphics. The clients have a very light data processing load. The AutomationObject Server nodes share the load of data processing, alarm management, communication to external devices, security management, etc. For details on the implementation of AppEngine and I/O server redundancy in a client server configuration, see the Widely-Distributed Network section later in this chapter. The following figure illustrates a client/server topology: Visualization Node Visualization Node Visualization Node Supervisory Network Network Device (Switch or Router ) AutomationObject Server Historian ( Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network This topology is scalable to include a greater number of servers. Including more servers distributes data processing loads and enables a higher load of I/O reads/writes. Client nodes can be added when additional operator stations are needed.

41 Identifying Topology Requirements 41 General Topology Planning Considerations When deciding on the topology to implement with Industrial Application Server, it is important to consider different topology variations. For example, it is critical to evaluate variations of the Client/Server topology, keeping in mind process requirements such as the number of I/O points, the update rate of variables at the server and client level, etc. The peer-to-peer nature of the communication between the Platforms requires adequate support for network connections. Windows XP Operating Station Notes Client operating systems such as Windows XP Professional can manage up to 10 simultaneous active connections with other nodes. In a pure client/server architecture, it is possible to have more than 10 client nodes running Windows XP Professional. The following requirements must be met: Client nodes are only running a Platform and InTouch Software. The IDE is not installed on the client nodes. The SMC (System Management Console) is installed with a Bootstrap and InTouch Software. However, the Platform Manager snap-in to the SMC should not be launched, as it connects to all Platforms in the Galaxy. Object Viewer is not run either from the SMC (Platform Manager) or from the executable file installed in the application directory. The client nodes are not running other applications, ActiveX objects, or functions that request data from remote sources (for example, ActiveFactory). This could cause more open connections on the client node. Also, consider any network shares on the client nodes as possible open connections. None of the client platforms are configured as InTouch Alarm Providers. To report alarms from client Platforms, place all Platforms in an Area hosted by any of the servers. A single client node does not require data from more than 10 server nodes. Note This topology was tested and the above requirements validated on a system that included 16 InTouch Software client nodes and five AutomationObject Server nodes executing ApplicationObjects. The Galaxy Repository was installed on a dedicated server. For more information on defining system size, see Chapter 10, "Assessing System Size and Performance." Finally, consider different options when deploying I/O Servers in a Galaxy, such as whether to run them on AutomationObject Servers or on dedicated computers, and redundancy strategies.

42 42 Chapter 2 I/O Servers on AutomationObject Server Nodes Both components (I/O Servers and AutomationObject Servers) can reside on the same node if I/O and data processing loads are not a constraint. In a topology that includes multiple I/O Servers, the load is balanced so that each AutomationObject Server executes a set of I/O Servers, DIObjects, and ApplicationObjects. The goal of this topology is to optimize network performance by reducing the network traffic between Galaxy components. Associated DIObjects and ApplicationObjects should run on the same Platform in order to minimize network traffic. The following figure illustrates this concept: Visualization Node Visualization Node Visualization Node Supervisory Network Network Device (Switch or Router ) AutomationObject Server I/O Server Historian (Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal PLC Network In this example, a single I/O Server runs on each AutomationObject Server node. The DIObjects required to communicate with a particular I/O Server are deployed to the same node, as well as all of the ApplicationObjects that will be obtaining data from the I/O Server. Communication between the DIObjects and the ApplicationObjects is handled via Message Exchange.

43 Identifying Topology Requirements 43 Dedicated I/O Server Nodes It may be beneficial to separate the I/O and data processing tasks so that they run on different servers. The following figure shows a dedicated node running all I/O Servers: Visualization Node Visualization Node Visualization Node Supervisory Network Network Device (Switch or Router ) AutomationObject Server Historian ( Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network To optimize the system performance and data throughput, deploy a platform to the dedicated I/O Server node. This platform hosts the AppEngine and DIObjects that need to communicate with the I/O Servers. In this scenario, the communication between the I/O Server and the AutomationObject Server is handled by Message Exchange protocol, which avoids DCOM issues related to poor performance and complex security settings. Note For details on security considerations in the FactorySuite A 2 environment, see See "Securing FactorySuite A2 Systems" on page 200.

44 44 Chapter 2 Legacy InTouch Software Applications This section describes coexistence of legacy InTouch Software applications within new FactorySuite A 2 systems. Sharing an InTouch Software 7.11 applications' data is possible without any additional work or software required on the InTouch Software side: At the Automation Object Server level, configure an InTouchProxy object to access data from the InTouch 7.11 application using the SuiteLink protocol. To facilitate the system's configuration, this object's configuration editor enables browsing the InTouch tagname dictionary. The following figure shows legacy InTouch 7.11 applications sharing data with the new Industrial Application Server system. This topology also contains InTouch View or InTouch run-time 9.0 clients that leverage data provided by the Galaxy. InTouch 7.11 Visualization Node Visualization Node Supervisory Network Network Device (Switch or Router ) AutomationObject Server Historian (Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network

45 Identifying Topology Requirements 45 Terminal Services Terminal Services provides the capability to run several sessions of the same InTouch Software application or different applications in a Terminal Server session. Terminal Services technology enables thin-client computer communication to a Terminal Server node, where multiple instances of InTouch Software applications run simultaneously. The software and hardware requirements for the client node are minimized since no programs are required at the client station accessing the application. A dedicated Terminal Server node is recommended for this topology. This node requires the following software components: Configuration Components (none) Run-Time Components Bootstrap* Platform* Terminal Services for InTouch Software 9.0 or higher* * Required component Only one Platform runs on a Terminal Server node, regardless of the number of sessions executed. However, the number of sessions affects the size of the license for the system. Note For information on FactorySuite A 2 Licensing, see the License Utility Guide. Consider different configuration options when using Terminal Services, such as whether to run Terminal Services on the same node as the AutomationObject Server; or run Terminal Services on a dedicated Server node. Running Terminal Services on a dedicated Server node presents a loading concern - AppEngine execution may be degraded by client sessions' resource consumption. Windows 2000 Server Terminal Services should be installed on the designated Terminal Services node using the Remote Administration mode selection. It is the default selection at installation. This option consumes significantly fewer computer resources (than the Application server Mode) when creating a Galaxy, importing or deploying an object. For detailed information on setting up Terminal Servers for InTouch Software on Windows 2000 Server, please refer to the Terminal Services for InTouch Deployment Guide.

46 46 Chapter 2 Windows Server 2003 The default installation mode is Remote Desktop for Administration (formerly known as Remote Administration mode). The mode selection is not available at installation. The following information contains topology descriptions of Terminal Services in the FactorySuite A2 environment. Dedicated Terminal Server Node A Terminal Server node is dedicated to running multiple InTouch Software application instances. A Platform deployed on that node enables the server to communicate with any AutomationObject Server in the Galaxy. Thin Client Thin Client Thin Client Corporate Network InTouch Terminal Server Network Device (Switch or Router ) Supervisory Network Network Device (Switch or Router ) AutomationObject Server Historian (Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network This configuration prevents any failure at the Terminal Server from impacting the AutomationObject Servers. A problem at the Terminal Server node only effects the visualization nodes; the AutomationObject Server continues operating. Note Configurations for the I/O-DA-OPC Server presented in the Client/Server topology can be included in a Terminal Server topology.

47 Identifying Topology Requirements 47 Server-Based Load Balancing for Terminal Server Clients Windows Network Load Balancing or Citrix Metaframe Load Balancing can be leveraged effectively within the FactorySuite A2 environment. Multiple dedicated Terminal Server nodes share the network load from all the clients that need access to the application sessions. In the event of a failure in any of the servers, the load from the clients originally connected to that server is handled by the remaining two servers. For detailed information about implementing load balancing, see the Terminal Services for InTouch Deployment Guide. Thin Client Thin Client Thin Client Corporate Network InTouch Terminal Servers Server Farm Network Device (Switch or Router ) Supervisory Network Network Device (Switch or Router ) AutomationObject Server Historian (Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network

48 48 Chapter 2 Terminal Services on the AutomationObject Server Node The following figure shows Terminal Services and the AutomationObject Server residing on a common node. All of the AutomationObject Server functionality runs in the console, while clients run multiple sessions of InTouch Software on that same node. I/O Servers could also run in the console of the Terminal Server node or on any other computer. Thin Client Thin Client Thin Client Supervisory Network Network Device (Switch or Router ) AutomationObject Server Terminal Server Historian (Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server PLC Network When considering this deployment, keep in mind that any problem in the Terminal Server/AutomationObject Server node impacts not only the visualization nodes, but also the I/O data collection and the processing of objects on the AutomationObject Server. For details about Terminal Services for InTouch Software, see the Terminal Services for InTouch Deployment Guide. For additional considerations for this configuration, see Chapter 10, "Assessing System Size and Performance."

49 Identifying Topology Requirements 49 Using the IDE with Terminal Services Application components are configured and deployed from the Integrated Development Environment (IDE) to target workstations and servers. The IDE can be used to configure and deploy an application to the Terminal Server, where multiple instances of InTouch Software applications can run simultaneously. Use Remote Desktop to the Galaxy Repository node to perform remote IDE access rather than another local IDE. Important! In order to launch an IDE session, the session must have user accounts in the Administrators group of the Terminal Server node. Terminal Services Thin Clients InTouch Terminal Server Bridge Ethernet AutomationObject Server Historian (Data and Alarms ) Engineering Station Configuration Database I/O Server Supervisory Network Network Device (Switch or Router ) PLC Network

50 50 Chapter 2 Widely-Distributed Network Networks distributed over a large geographical area. This network incorporates a variety of communication components and accounts for network delays, intermittent traffic, and network outages. Widely-Distributed networks are also known as "Intermittent" networks. Because of low bandwidth and/or high traffic, distributed networks tend to experience delays or breaks in communication. The following topology diagram includes 3 connection types: Dial-up Wireless/Radio WAN Terminal Services Clients (Thin Client) Visualization (Data, Alarms, History) Dial-up 28.8k bps line Ethernet Terminal Server SuiteVoyager Portal AutomationObject Server Historian (Data and Alarms) Engineering Station Configuration Database SCADAlarm I/O Server Network Device (Switch or Router ) Supervisory Network Network Device (Switch or Router ) RTU Radio Modem Control Network RTU Radio Modem (RS-232) PLCs RS-485 Network RTU Radio Modem Level Transmitters Detailed information regarding Distributed Network configuration is included in Chapter 11, "Working in Wide-Area Networks and SCADA Systems."

51 Identifying Topology Requirements 51 Best Practices for Topology Configuration The following Best Practices focus on configuring your network architecture and software components within a FactorySuite A2 system environment. Note The following information focuses on non-redundant topologies where a single Network Interface Card (NIC) is used on each node. For detailed information about Redundancy and dual NIC configuration, see Chapter 3, "Implementing Redundancy." Network Configuration Verify Required Connection Settings If your network administrator or Internet Service Provider (ISP) requires static settings, one or more of the following NIC settings is necessary: A specific IP address. DNS addresses. DNS domain name. Default gateway address. WINS addresses. Use Fixed IP Addresses on Industrial Application Server Nodes Fixed IP addresses, while not required, are recommended in cases where using DHCP interrupts specific topology component functionality. For example, when the Historian node uses DHCP, and its connection is broken and restored (planned maintenance, connection failure, etc.), the restoration of data via store/forward is delayed due to the DNS name resolution interval (no data is lost). This interval is generally between 12 and 15 minutes. Note A regular disconnection of the Historian should not cause delay. The stored data is forwarded when the DNS name is automatically resolved, or when the Historian is successfully "Pinged." The Ping operation invokes the name resolution operation. Another example is when using InTouch Software and Terminal Services. Using DHCP in this case will disrupt some specific component functionality (wwlogger on version 7.1/7.11, SuiteLink, and Terminal Service load balancing configurations). Note For details on InTouch Software and Terminal Services in this scenario, see Tech Note 358: InTouch, Terminal Services, and DHCP.

52 52 Chapter 2 If you must use DHCP, keep in mind that it is possible to reserve IP addresses for specific computers; in the previous example, when the Historian node has a reserved address, store/forward operates without delay. Consult with IT staff for complete network configuration details. Note Industrial Application Server 1.5 and later supports DHCP-assigned IP addresses. Fine-Tune Protocol Settings Specify Protocol Access Order. Network performance can often be improved by changing the access order of protocols bound to those providers. For example, the LAN connection is enabled to access NetWare and Microsoft Windows networks, which use IPX and TCP/IP. Your primary connection is to a Microsoft Windows network that uses TCP/IP. Move Microsoft Windows Network to the top of the Network providers list on the Provider Order tab. Move Internet Protocol (TCP/IP) to the top of the File and Printer Sharing for Microsoft Networks binding on the Adapters and Bindings tab. Install and enable only the necessary network protocols. Limiting the number of protocols on your computer enhances its performance and reduces network traffic. If the computer encounters a problem with a network or dial-up connection, it attempts to establish connectivity by using every network protocol that is installed and enabled. By installing and enabling only the protocols used by the system, status information is returned efficiently. Determine Available Network Bandwidth Bandwidth information is typically managed by the IT group because network resources may be shared with other departments and operations. The ideal condition is to have continuous access to network status, to prevent and/or correct any network-related application issues. Some network devices such as switches and routers contain self-diagnostics tools that provide information on network performance using OPC protocol. If you have access to such devices, you can configure instances of the OPC Proxy to monitor the network bandwidth. Verify Basic Network Communication Before attempting any deployment of applications or network operation, verify that each node in the system can be pinged by its node name. You may need to check the DNS configuration or configure the Hosts files. For example, from the Galaxy Repository node, you should try to ping (by name) the remote node to which a platform is going to be deployed.

53 Identifying Topology Requirements 53 Review Firewall Usage If you have a corporate firewall, hardened Device (Appliance) or Software application on a dedicated hardened platform, the implementation of a personal firewall on each PC is unnecessary. Software Configuration FactorySuite A2 Application Coexistence When installing multiple FactorySuite A2 applications on one node, always install the oldest components first. For example, Wonderware I/O Server technology pre-dates ArchestrA-based technology. Common Components for DAServers are newer than those that come with most I/O Servers. Thus, install I/O Servers first, then DAServers. Anti-Virus Software Although it is desirable to run an Anti-virus software on each node in the system, it may impact the performance of some tasks. To reduce the effect of the Anti-virus program, disable the auto-update feature of any virus scan software and manage the updates either manually or by a centrallyadministered scheduler. The following files should be excluded from scanning in the AutomationObject Server nodes: C:\Program Files\ArchestrA\Framework\Bin\CheckPointer C:\Program Files\ArchestrA\Framework\Bin\GalaxyData C:\Program Files\ArchestrA\Framework\Bin\GlobalDataCache C:\Program Files\ArchestrA\Framework\Bin\Cache The Virus scan should include the logger files (*.aeh), typically found in: C:\Program Files\Common Files\ArchestrA User Account Requirements Take note of the account that is created during installation of the FactorySuite A 2 System components for the username and password. As you expand a FactorySuite A 2 system, you are required to use this same account on all computers that are part of the same Galaxy. Use Time Synchronization Configure the computers in a Galaxy to synchronize time at regular intervals. This is particularly important for alarm and data history. The Historian Node is a good candidate for the computer by which all other computers will synchronize time.

54 54 Chapter 2 Licensing Requirements Be sure that the appropriate licenses are installed where required, i.e Galaxy Repository, Visualization nodes, etc. Note that an I/O server license is required in every node that runs an I/O Server. Note For detailed information on licensing requirements, see the License Utility Guide. I/O Server Connectivity The following section provides a high-level discussion of I/O Server implementation in the FactorySuite A2 environment. I/O and DAServers: Best Practice The server you use and the topology you construct depends upon your existing system and the needs of your process. See the Compatibility Matrix on the Wonderware esupport website ( for information about compatibility between FactorySuite components, Microsoft operating systems and SQL server releases. For example, an I/O server might better meet the needs of a system with a number of legacy components, but would not itself be suitable for a system requiring OPC-based communication. I/O Servers I/O Servers provide connectivity for devices using DDE, FastDDE and SuiteLink protocols. Wonderware's I/O Servers can connect every FactorySuite 2000 and FactorySuite A2 System component. I/O Servers also connect various popular PLC, RTU, DCS and ESD systems. Wonderware's Rapid Protocol Modeler (RPM) Kit enables I/O Server customization to suit your needs. The RPM Kit can configure connections between FactorySuite applications and devices with standard and non-standard protocols. It handles serial and TCP/IP communications with either ASCII or binary protocols. The RPM Kit can be used to profile and save a protocol. DAServers The Data Access Server (DAServer) provides simultaneous connectivity between plant floor devices and SuiteLink, OPC and DDE/SL-based client applications that run under Microsoft's Windows 2000/2003/XP Professional operating systems. DAServers can operate with many current FactorySuite 2000 client components, as well as with FactorySuite A2 product offerings, when these are used with their associated DIObjects. The DAServer supports run-time configuration, device additions and device/server-specific parameter modifications.

55 Identifying Topology Requirements 55 Note If the DAServer has to use specific hardware, for example, a specialized card, it is quarantined until the physical hardware is installed. The DAServer is like a driver: it can receive data from different controllers simultaneously. For example, a DAServer might use OPC to access data remotely in one machine, and use InTouch Software to communicate with another machine. When a DAServer transfers data, it also transfers a timestamp and quality codes. The DAServer is flexible enough to be used in a variety of topologies, but some topologies are more efficient than others. For example, the DAServer can connect to the OPC Server directly across the network, or FactorySuite Gateway can be placed on the same machine as the OPC DAServer and SuiteLink can be used to link the server to devices. Of the two topologies, using FactorySuite Gateway is more efficient than connecting the DAServer directly to the OPC Server. DIObject Advantages Device Integration Objects (DIObjects) represent communication with external devices. DIObjects may be DINetwork Objects (for example, the Redundant DIObject) or DI Device Objects. DIObjects (and their associated AppEngine) can reside on any I/O, DA, or Automation Object Server node in the Galaxy. DIObjects allow connectivity to data sources such as DDE servers, SuiteLink servers, OPC servers, and existing InTouch Software applications. The advantages of using DIObjects are as follows: When IDE software is installed on an Industrial Application Server, DIObjects allow you to configure, deploy, and monitor DAServers from one centralized location. DIObjects can be used to represent all devices and PLCs in a network, enabling representation of an entire plant, including a hierarchical view of network connectivity. DIObjects are so closely tied to the DAServer that when an object is deployed across the network, it remotely installs the DAServer (This means that you can install the DAServer without going to the actual machine, and that the DAServer connects immediately.). DIObjects are very closely tied to the DAServer they are assigned to, so that when an object is deployed, it brings with it all code, including registry, scripting, attributes, and parent. Note that in a large project, this process may take some time. However, tremendous savings are achieved when comparing centralized deployment with individual tasks should the Servers be separately installed and configured on each node.

56 56 Chapter 2 Extending the IAS Environment This section provides a high-level summary of protocols used in the IAS environment, and common extensibility scenarios with the related communication protocol support. The following figure represents a widely-distributed (SCADA) network: Terminal Services Clients (Thin Client) Visualization (Data, Alarms, History) Dial-up 28.8k bps line Ethernet Terminal Server SuiteVoyager Portal AutomationObject Server Historian (Data and Alarms) Engineering Station Configuration Database SCADAlarm I/O Server Network Device (Switch or Router ) Supervisory Network Network Device (Switch or Router ) RTU Radio Modem Control Network RTU Radio Modem (RS-232) PLCs RS-485 Network RTU Radio Modem Level Transmitters

57 Identifying Topology Requirements 57 The following figure the shows the same network represented using the communication protocols supported in a FactorySuite A2 system environment: Terminal Services Thin Clients Visualization (Data, Alarms.History) Dial-up 28.8k bps line Ethernet SuiteLink (Alarms) Terminal Server SuiteVoyager Portal Historian (Data and Alarms) Engineering Station Configuration Database AutomationObject Server SCADAlarm I/O Server Supervisory Network SuiteLink (Alarms) MX Control Network OPC/DCOM SuiteLink RTU Radio Modem RTU Radio Modem (RS-232) PLCs RTU Radio Modem RS-485 Network Level Transmitters The following information summarizes the protocols shown in the previous figure: MX: Message Exchange consists of two major components, Local Message Exchange (LMX) and Network Message Exchange (NMX). LMX is that part of message exchange that provides direct services to a client program for accessing AutomationObjects. NMX is the component that supports communications between processes and between computers. Note MX is not used for communications with data servers. Thus, it is not a replacement for DDE, SuiteLink or OPC. OPC: Supports the OLE (Object Linking and Embedding) for process control specification. OPC uses the client-server model and Microsoft COM/DCOM (Distributed Component Object Model) protocols for vendor-independent data transfer. SuiteLink: Wonderware s high-speed communications protocol. Based on TCP/IP, SuiteLink offers high-throughput, reliable communication between FactorySuite components in a Windows NT and Windows Server environment. RDP (Remote Desktop Protocol): Designed for communication between a server and a remote Windows desktop. RDP is not shown in the above figure.

58 58 Chapter 2 SQL Connection: Specialized connection services for client (ActiveFactory, SuiteVoyager Software, etc.) and MDAS components. The SQL connections are not shown in the previous figure. Note For more information on SQL Connections, see the IndustrialSQL Server Historian Online documents. Communication Requirement: Communication Between Objects, Engines and Platform(s) (local or remote node) Protocol Local Message Exchange (LMX): Provides direct services to a client component. This includes infrastructure services that support communication between AutomationObjects on the same Engine. LMX routes messages to NMX when it needs to communicate to another process (or engine). LMX is packaged as an internal component of all Engines. Network Message Exchange (NMX): Includes infrastructure services that support communication between objects on different Engines that are either on the same Platform or on different ones connected by the network. NMX provides queueing capabilities for interprocess communications. Communicate with 3rd Party I/O Servers Galaxy Administration using Terminal Server NMX is packaged as part of the Platform. Open Process Control (OPC): Each object has a name, value, time stamp, and quality. DCOM uses the RPC (Remote Procedure Call) mechanism to send and receive information between clients and servers on the same network. DCOM is implemented only for Windows-based operating systems. Remote Desktop Protocol (RDP): It is installed by default with Windows Server 2003 Terminal Services.

59 Identifying Topology Requirements 59 Communication Requirement: Communication Between FactorySuite Applications Communication with legacy I/O Servers Protocol SuiteLink: SuiteLink's support for timestamps, value and quality are especially important in alarming, archiving, and SCADA applications. Dynamic Data Exchange (DDE): An interprocess communication (IPC) system built into the Macintosh, Windows, and OS/2 operating systems. DDE enables two running applications to share the same data. DDE is an event-driven communication which allows data to be transmitted from an actual device to the final application.

60 60 Chapter 2

61 Implementing Redundancy 61 CHAPTER 3 Implementing Redundancy IAS Redundancy is achieved by deploying combinations of AppEngines and DIObjects on two nodes. Each node has dual, dedicated NICs. Implementing redundancy ensures continuous operation by providing an AppEngine that remains active in the event of a single system component failure. This configuration operates on the premise that one engine is in an Active State while the other is in a Standby State waiting to take control. The following information describes Redundancy in the context of Industrial Application Server. Contents Redundant System Requirements NIC Configuration: Redundant Message Channel (RMC) Redundant DIObjects Redundant Configuration Combinations Alarms in a Redundant Configuration Failover Causes in Redundant AppEngines Redundant System Checklist Tuning Recommendations for Redundancy in Large Systems

62 62 Chapter 3 Redundant System Requirements A system configured with redundant AppEngines consists of a Primary and a Backup AppEngine. The redundant pair is configured in the (Primary) AppEngine editor. The AppEngine enabled for Redundancy is considered the Primary Engine of the redundant pair. When the Primary engine is configured for Redundancy, an additional (Backup) engine is automatically created (see the following figure). Use the SMC, Object Viewer, or the IDE to work with the Redundant Engine pair. The IDE provides visualization of the redundant pair in the Deployment view pane. The following figure shows a pair of Platforms and Engines (on the same node). Note the Engine icons and Engine names. The name (Backup) is appended to the Redundant AppEngine created from the Primary AppEngine: Note When enabling redundancy, do not select the Restart the engine when it fails option (in the Primary engine's General editor tab). Redundant Engine configuration requires the following: Redundant pair AppEngines must be deployed to different platforms. Both nodes hosting the redundant AppEngine pair should run the same version and service pack levels of supported Operating Systems. The Redundant Message Channel of each platform must be configured by assigning the corresponding IP address in the Platform editor. Best Practice Platforms hosting Primary and Backup AppEngines must have identical configurations for the following elements: Software providing or getting data from/to the AutomationObject Server, i.e. SuiteLink, DDE,OPC Servers, etc. Store and Forward directories. Common user-defined attributes (UDAs). Common scripting.

63 Implementing Redundancy 63 Note For more information on UDAs and scripting, see Chapter 5, "Working with Templates." Changing the default Platform and Engine settings depends on the size of the system, the number of I/O points, and other variables. Detailed information on tuning the Platform and Engine settings is included in Tech Note 410: Fine-Tuning AppEngine Redundancy Settings. AppEngine Redundancy States The deployment sequence (Cascade, Primary first, or Backup First) of the AppEngine pair determines which AppEngine takes the Active State. When AppEngines are deployed individually, the first engine deployed takes the Active state while the second engine deployed takes the Standby state. The engines maintain their states until a failure occurs. If either engine is deployed by itself, it assumes the Active Engine state. In a cascade deploy from the Galaxy Object, when the primary AppEngine is available it becomes Active while the Backup AppEngine goes to Standby. If a network communication problem or a failure (such as computer hardware loss or failure) occurs, the Standby AppEngine assumes the Active state and the engine that was in the Active state may assume the Standby state. When the cause of the failure has been remedied, this engine assumes the Standby - Ready state. For more information on redundancy, see the IDE User's Guide. NIC Configuration: Redundant Message Channel (RMC) Redundant AppEngine functionality requires two computers, each with two Network Interface Cards (NIC). The first network card is for the Supervisory network; the second card is for the Redundancy Message Channel (RMC). The RMC is a dedicated ethernet connection between the platforms hosting redundant engines. The RMC is vital to keep both engines synchronized with alarms, history, and checkpoint items from the Active engine. Each engine also uses this Message Channel to provide its health and status information to the other. Note Access Network Connections properties from the Windows Control Panel.

64 64 Chapter 3 Primary Network Connection The NIC cards require the following configuration on both nodes: To configure the Primary network connection 1. In the Network Connections window, right-click Primary Network and select Properties. 2. Select TCP/IP and configure the Properties to obtain either dynamic or static IP address. 3. Configure the remaining parameters as appropriate, i.e. DNS, WNS, etc. RMC Network Connection To configure the RMC connection 1. In the Network Connections window, right-click RMC Network and select Properties. 2. Select TCP/IP and click the Properties button. 3. Select Use the following IP address. See your network administrator for IP address and subnet mask. The IP address must be fixed and unique. 4. In the TCP/IP Properties dialog box, click the Advanced button, then select the DNS tab. Be sure the Register this connection's address in DNS checkbox is not checked. Best Practice Assign a descriptive name to each network connection to easily identify its functionality. From the Network Connections window, rename the Local Area Connections i.e. "Primary Network" and "RMC Network." To assign Network Services primary connections 1. In the Network Connections window, select Advanced/Advanced Settings from the main menu. 2. Select the Adapters and Bindings tab. 3. Set the Primary Network as the first connection to be accessed by network services. Use the Up/Down Arrow buttons to re-order the list. 4. Verify that the normal connection between the redundant pair uses the primary network. This is done using the PING command (from the DOS Command Prompt) with the redundant partner's node name. Verify that the node name resolves to the IP Address of the partner's primary network card.

65 Implementing Redundancy 65 Redundant DIObjects Configuration The following section explains implementing redundant DIObjects. AppEngines can host redundant Device Integration Objects (DIObjects). The Redundant DIObject is a DINetwork Object used to enable continuity of I/O information from field devices. The redundant DIObject provides the ability to configure a single object with connections to two different data sources. If the primary data source fails, the redundant DIObject automatically switches to the backup data source for its information. There is a one-to-two relationship between an instance of the redundant DIObject and the running instances of the source DIObjects; that is, for each redundant DIObject, a pair of source DIObjects is deployed. Visualization Nodes Supervisory Network Redundant DIObject AutomationObject Server - I/O Server AppEngine 1 Platform 1 DI_1 DAServer_1 DI_2 DAServer_2 PLC Network ABTCP DH+ The following naming practices are recommended for implementing redundant DIObjects: If the I/O or DAServer resides on the same node as the AppEngine hosting the DIObject, configure the server node name in the General tab as <Blank> or <Localhost>. If the I/O or DAServer resides on a remote node, any node name is acceptable as it refers to the same remote node regardless of where the DIObject is located.

66 66 Chapter 3 In the previous example, the PLC sent data using two unique protocols. It is also common for the PLC to send data through two ethernet ports using the same protocol, via different I.P. addresses. In this case, the following redundant DIObject configuration is recommended: Visualization Nodes Supervisory Network Redundant DIObject AutomationObject Server - I/O Server AppEngine 1 Platform 1 DI_1 DAServer_1 Topic1 I.P.1 DI_2 DAServer_2 Topic1 I.P.2 PLC Network ABTCP ABTCP The figure shows two unique DAServer instances, each using the same topic and pointing to a unique I.P. address. The DAServers in this scenario can be also be deployed on different machines. Common Configuration Requirements Redundant DIObject configuration requires the following: Source DIObjects do not have to be of the same type, but must support the same type of Scan Group and have the same items address space. The Scan Groups configured in the Redundant DIObject must also be configured in both the Primary and Backup DIObjects. The configuration must include at least one Scan Group. The names of the Primary and Backup DIObject must be different. The Primary DIObject attribute refers to the name of the DIObject that will be used as the primary source of I/O attributes. The Redundant DIObject's Editor supports creating/configuring Scan Groups, BlockReads, and BlockWrites. The Redundant DIObject can have configurable I/O points (Tag dictionary), which are periodically scanned for their value. The redundant DIObject supports Subscription, Read Transaction, and Write Transaction on I/O points.

67 Implementing Redundancy 67 Redundant DIObject Behavior at Run-Time After the redundant DIObject is initialized, its state changes to Startup. The object opens MX communications and registers a reference to ScanState to track whether the DIObject is deployed. If the DIObject is off scan, the redundant DIObject treats it as a bad data source. The ProtocolFailureCode and ConnectionStatus attributes provide status of the source device. During run-time, the redundant DIObject performs the following tasks: 1. Adds newly activated attributes to the Active DI source. 2. Updates attributes with new values from the Active DI source. 3. Monitors the connection with the Active and Standby DI source. If the connection to the Active DI source is lost, the object switches to the Standby DI source. If both DI sources are in bad state, the object raises the Connection Alarm. Redundant Configuration Combinations Multiple redundant configuration combinations are possible. The combinations include redundant AppEngines and Redundant DIObjects. It is important to select the configuration that provides the best performance and robustness. The following examples present recommended configurations for the Dedicated Standby and Load Shared scenarios. Dedicated Standby Server - No Redundant I/O Server This configuration includes a dedicated Standby node ready to take control of the system when the Active Engine is off-line (refer to the following figure). AppEngine1 hosts all AppObjects as well as DIObjects. The I/O Server is installed on both nodes but the DIObject collects data from the node where the Active engine resides. To provide a higher degree of reliability to the system, you can implement a script in the DIObject to set the Redundancy.ForceFailoverCmd attribute in the AppEngine object to True when the connection with the PLC fails.

68 68 Chapter 3 The following figure includes Alarm configuration. For details, see "Alarms in a Redundant Configuration" on page 78. Visualization InTouch Alarm Provider Visualization Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DI DAServer RMC Historian ( Data and Alarms ) Alarm Logger Network Device (Switch or Router ) PLC Network Load Sharing Configurations Load Sharing distributes the system's processing load between two nodes. The two nodes can also be configured to backup each other. The primary benefit of Load Sharing is to reduce failover time: only 1/2 the objects must fail over. A system with redundant AppEngines can host Active and Standby Engines of different redundant pairs on the same node. This configuration enables efficient use of system resources while providing high availability for both nodes. However, configuration of redundant Engines on the same node requires thorough evaluation of the following critical (Performance Monitor) counters: CPU and Memory use on each node. Ensure each AOS node runs at a maximum of 25-30% CPU load. This CPU load represents the resources used by each AOS in steady condition considering Active and Standby engines running in each node as well as any other applications. When a failover occurs one of the AOS nodes will host all the Active engines in the pair. Hosting implies a CPU load increase to a total of 50-60%. It is important to note that although the computers hosting the redundant AppEngines do not have to be identical, the total load of the application must not exceed 60% of CPU usage of the smallest computer.

69 Implementing Redundancy 69 Load Shared - Non Redundant I/O Data Source - Using DIObjects Both AOS nodes host Active and Backup engines for each other. If one node fails, the remaining one hosts all Active Engines for both nodes. The following figure shows standard DAServers with OPC Client or DDE/Suitelink client objects (DIObjects). When both AOS nodes use the same DAServer to communicate with the PLC, the DIObject in the new Active engine refers to the server running in that node when the failover occurs. The DIObjects on each node are configured to point to the local DAServer, leaving the Node Name blank in the DIObject editor. When a failover occurs, the DIObject in the new Active Engine will refer to the local existing instance of the DAServer that is currently running in that node. When the AOS nodes use different DAServers, both servers must be installed on each node. One of the DAServers will provide data to the local Active DIObject (i.e. DI1), while the other server feeds data to the other DIObject (i.e. DI2) after the failover. Use the Redundancy.ForceFailoverCmd AppEngine attribute in a script (in the corresponding DIObject) to trigger the failover in the event of a communication failure with the PLC Network. The following figure includes Alarm configuration. For details, see "Alarms in a Redundant Configuration" on page 78. Visualization InTouch Alarm Provider Visualization Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DI 1 DAServer A AppEngine 2 (Backup) RMC AppEngine 2 DI 2 DAServer A AppEngine 1 (Backup) Historian ( Data and Alarms ) Alarm Logger Network Device (Switch or Router ) PLC Network

70 70 Chapter 3 Load Shared - No Redundant I/O Data Source - DI Network Objects This variation of Load Shared configuration uses DI Network objects (i.e. DI ABTCP, DI Modbus, etc.). When considering a Load Share configuration, remember that some DI Network objects may allow only one instance of the DAServer to be deployed on a single computer. In a Load Shared scenario, when one of the AppEngines fails, the system would try to run two instances of the same DI Network object on a single node and may cause conflicts. DI Network object configurations in the Load Share context are presented in Scenario 1 and Scenario 2 (following pages). For details on the DI Network object requirements and functionality, see the specific DI Network Object Help provided with the Object. Scenario 1 A set of AppObjects is hosted by AppEngine1 and another set by AppEngine2. These two engines are hosted by different platforms. AppEngine 1 and AppEngine 2's backup engines reside on the opposite node. One instance of a DI Network object resides in any of the nodes providing data to AppObjects in both nodes. Use the Redundancy.ForceFailoverCmd AppEngine attribute in a script (in the DI Network Object) to trigger the failover in the event of a communication failure with the PLC Network. The following figure includes Alarm configuration. For details, see "Alarms in a Redundant Configuration" on page 78. Visualization InTouch Alarm Provider Visualization Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DINetwork DAServer AppEngine 2 (BACKUP) RMC AppEngine 1 (BACKUP) AppEngine 2 Historian (Data and Alarms ) Alarm Logger Network Device (Switch or Router ) PLC Network

71 Implementing Redundancy 71 Scenario 2 This scenario provides a very powerful and reliable solution. To avoid the conflict with multiple instances of the same DI Network in a node after a failover occurs, you can arrange the system as shown in the following figure. The configuration in AOS1 is mirrored in AOS2. AOS1 hosts AppEngine 1, which is part of a redundant pair with AppEngine 1 (BACKUP) and is hosted by AOS2. Additionally, AppEngine 1 hosts RDI1, which provides high availability at the I/O level. RDI1 is configured to use DI1Network as the Primary DI source and DI2 Network as the Backup DI source. This configuration provides high availability at the data execution level and I/O data acquisition in a very efficient approach. In the event of a failure in AOS1, AppEngine 1 will failover to AppEngine 1 (BACKUP). Once AppEngine 1 fails over the Standby engine, RDI1 will also switch to DI2 Network in the new node. On the other hand, if there is a communication problem at the DI1 object level, the RDI1 object will automatically switch to DI2 Network while AppEngine 1 still runs on AOS 1. AppEngine E3, which is not a redundant AppEngine, hosts DI1 Network. By keeping the DI1 and DI2 Network objects on separate non-redundant engines, you are avoiding the conflict created by having two instances of the same DI Network object on the same node. The following figure includes Alarm configuration. For details, see "Alarms in a Redundant Configuration" on page 78. AOS 1 AOS 2 AppEngine 1 RDI1 RDI 2 AppEngine 2 AppEngine 2' AppEngine 1' AppEngine 3 DINetwork1 DINetwork2 AppEngine 4

72 72 Chapter 3 The topology supporting this configuration is shown below: Visualization InTouch Alarm Provider Visualization Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 RDI 1 AppEngine 2 (BACKUP) AppEngine 3 DINetwork 1 DAServer RMC RDI 2 AppEngine 1 (BACKUP) AppEngine 4 DINetwork 2 DAServer PLC Network Historian (Data and Alarms) Alarm Logger Network Device (Switch or Router ) Load Shared - Redundant I/O Data Source This variation of the Load Shared configuration includes a set of redundant nodes running the I/O Servers. AOS1 and AOS2 are configured as redundant pairs in a Load Shared scenario. In the event of a failure, one of the nodes hosts all AppObjects in both servers. This set up provides high availability for the execution of AppObjects. Alternatively, the I/O data level is protected by implementing a pair of remote I/O Server nodes. Each server hosts the corresponding DIObject and I/O Server (DAS, DDE/Suitelink or OPC servers) or DI Network objects and DAServers. AppObjects on each engine reference I/O points in the local RDIObject. The RDIObjects switch between I/O Server nodes if a failure in any of those nodes occurs. Using redundant I/O Data Sources provides the following benefits: The communication protocol between the I/O Server node and the AOS is MX. This protocol is optimized for data transfer over the network, with special emphasis on slow and intermittent networks. As the I/O Server uses MX protocol to transfer data, it simplifies configuring OPC communication over the network (DCOM security settings), and overcomes the deficiencies of DCOM communications. Using a platform and an AppEngine on those nodes provides additional diagnostic of conditions associated to the system. These can be historized and alarmed in the same way as with AppObjects.

73 Implementing Redundancy 73 The following figure includes Alarm configuration. For details, see "Alarms in a Redundant Configuration" on page 78. Visualization InTouch Alarm Provider Visualization InTouch Alarm Provider AOS (PRIMARY) AOS (BACKUP) Supervisory Network I/O Server 1 I/O Server 2 AppEngine 1 AppEngine 4 AppEngine 2 AppEngine 3 AppObjects RDI RMC AppObjects RDI DI 1 DAServer 1 DI 2 DAServer 2 Network Device (Switch or Router ) AppEngine 4 (BACKUP) AppEngine 1 (BACKUP) Historian (Data and Alarms ) Alarm Logger PLC Network Run-Time Considerations The following information summarizes run-time behaviors between Redundant Engines. Establishing RMC Communication The Active and Standby Engines communicate with each other during run-time and use the RMC to monitor each other's status. The redundant engines use the Remote Partner Address (RPA) attribute to locate each other and communicate. The RPA attribute contains the IP address or host name of the platform hosting the partner engine. At startup, each redundant AppEngine establishes communication with its partner. When the failover service receives a connection across the RMC, it updates the RPA attribute of the receiving engine if it is different than the current configured value. Note The value of the RPA may be different if a partner engine has been relocated to a different platform.

74 74 Chapter 3 Checkpointing AppEngines store specific attributes in memory, then write them to disk in both single- or redundant Engine configurations. The frequency of the write operation is determined by the Checkpoint period setting in the AppEngine editor. Note Checkpoint period configuration details are included in "Tuning Redundant Engine Attributes" on page 87. The checkpointed attribute types include: Scan Rate Checkpoint Directory location (default is blank but can be modified) StartUp Attributes StartUp Type (Automatic, Semi-Automatic, Manual) StartUp Reason Redundant AppEngines maintain data synchronization through the RMC. Data synchronization is accomplished by reading checkpointed attribute values written to disk on each node, at each scan. The checkpoint operations occurs at a pre-defined rate in the local node (Scheduler.ScanPeriod). The same operations (write to memory, then to disk) occur on the Backup AppEngine at every scan (via the RMC). When the Standby AppEngine becomes active, it reads the checkpointed values from the designated file in the local (BackUp) node. The system updates the Standby Engine with the values that were sent and written to disk in the last scan before the Active Engine failed. The following attribute types are checkpointed: Attributes with Category User Writable or Object Writable that are not extended as Input/Output and Input extensions. Calculated Retentive category attributes are always checkpointed. Complete a thorough evaluation and selection of checkpointed attributes. Unnecessary checkpointing may degrade the performance of the system by writing extra values to the Local/Backup disks, and increase data traffic over the RMC. Deployment Considerations Automation Objects are always deployed to the Active Engine: If the Primary Engine is the Active Engine of a redundant pair, objects are deployed to the Primary Engine. If the Backup Engine is the Active Engine, the objects are deployed to the Backup Engine. When an Active Engine becomes the Standby, the Engine sets all objects off scan, shuts down all features that make up the object and stops executing all deployed objects. All objects are unregistered on the previously active engine.

75 Implementing Redundancy 75 When a Standby Engine becomes Active, the Engine calls Startup on all features that make up the objects. The call-up includes a method that shows the objects are starting up as part of a failover. The newly active engine calls SetScanState on all features and begins executing all objects that are on scan. Best Practice To deploy objects in a Load Shared configuration 1. Deploy the platforms individually rather than in a cascade. 2. Cascade deploy the primary Engines. 3. Finally, cascade deploy the backup Engines. Always deploy the primary Engine first. Scripting Considerations When failover occurs, attribute values keep their initial states. Scripts and SQL connections to databases that were interrupted by the failover must be restarted. OffScan scripts are executed in the event of a forced failover. Any state, such as local variables or calculated attributes, that is not kept in checkpointed attributes is not passed to the objects started on the newlyactive Engine. If an attribute value is being passed to the database when failover occurs, the attribute returns to its initial value when the object goes On Scan in the new active Engine. Before the attributes can be updated, the database connection must be restored. Script Behavior When the Standby Engine Becomes Active When a Standby Engine becomes active, it sets the Engine.StartupReason attribute to indicate the startup cause. The attribute string can be accessed in a script to determine the startup reason. The following reasons are possible: Starting_AfterDeploy: Engine starts from standard deploy. Starting_From Standby: Engine starts from failover. Starting_FromCheckpoint: Engine starts from reboot or AutoStart configuration. These attributes can also be used to execute scripts that re-initialize variables and COM objects. After a failover occurs, scripts in the new Active engine are executed based on the trigger type they use i.e. Startup, On Scan, Periodic and Data Change.

76 76 Chapter 3 Use Startup and OnScan scripts to initialize conditions used later in the script. In many cases the initialization is required only when the object is deployed/redeployed, or when the AppEngine and or platforms are restarted. In the case of a failover, the requirement may be to continue operating using values from the checkpoint rather than re-initializing the conditions. The Redundancy.FailoverOccurred attribute is set to "True" for the first scan right after the failover occurs; after the first scan the attribute is automatically reset to "False." Using this attribute as a script condition initializing the variables prevents the script from running when the system recovers from a failover. Similarly, Data Change scripts execute when the object is deployed, the engine re-started and the Standby engine becomes active after a failover. Using the Redundancy.FailoverOccurred in an "If-then-else" statement will prevent the script from executing after the failover. Any script that is set with an Execution type of Execute and a trigger type of Periodic will have the following behaviors after an AppEngine failover. The situation is described using a period of 60 minutes as an example time period: The script executes the first time when the engine is deployed. E.g. T0. The next execution time will be 60 minutes later. E.g. T60. The redundant engine fails over and the Standby engine is fully running in the Active state at T30. The Periodic script(s) will restart with the period reset to T0. The period for the execution of the Periodic script(s) will be shorter than planned for, or possibly longer if an engine failover occurs shortly before the time period elapses. Some applications may have critical data generated by a Periodic script. Do not use Periodic type scripts where the time period could be shorter, or longer, and this is critical information being managed by this script. Instead, set up the script to run using a Condition and set up a UDA for the trigger. Then for a time base, use System Time and calculate the time period from this to set the condition. The UDA current value is maintained in the failover and the System Time is real time versus an expiring timer. Shutdown and OffScan scripts will execute after an orderly completed failover, i.e. using ForceFailoverCmd, or in the event of Primary Network failure. Asynchronous Scripts QuickScripts must be evaluated to anticipate likely delays (SQL Query completion, calling COM or.net objects, etc.) due to network transport or intensive database processing. When a delay in script completion is likely, set the QuickScript to run asynchronously. If not set to run asynchronously, it is possible that the non-asynchronous QuickScript could cause the Engine to miss the following scan while waiting for the script to finish executing. Note The Runs asynchronously option must be manually selected within the Scripts tab page of the Object Editor; it is not set by default.

77 Implementing Redundancy 77 Once set to run asynchronously, the QuickScript will not be cut off when the scan is completed. When a problem occurs, the script could "hang" if the process never completes, as in the case of a SQL query that never returns a rowset or even an error message. When the QuickScript's ExecuteTimeout.Limit value is reached, the ExecuteError.Alarmed and ExecuteError.Condition attributes are set. In this context it is useful to monitor these attributes and log a message when the maximum timeout threshold is exceeded. History Historical data is sent to the Historian only from the Active Engine. The Active Engine processes historical data and sends it to the Historian when the Historian is available. If the Historian becomes unavailable, the Active Engine stores the data locally (in Store Forware History Blocks) and forwards it when the Historian becomes available. In the meantime, local Store Forward data is transferred to the Standby Engine via the RMC. When an engine enters Store Forward mode, it synchronizes its data with its partner engine. Store Forward data is transferred (and synchronized) every 30 seconds, so no more than 30 seconds can be lost in the event of an Engine Failure. Note Attributes and tags which were not configured in the Historian before failover are not stored. History: Redundancy Diagnostics In order to facilitate management of Store Forward data collected across multiple failures and to improve diagnostics, the Active Engine has attributes which show the status of Store Forward. The following information is available: Store Forward data has been collected for engine: (Engine.Historian.InStoreForward_Standby) Store Forward data lost: (Engine.Historian.StoreForwardDataLost_Standby) Store Forward data cannot be stored on active engine in store forward mode: (Engine.Historian.StoreForwardProblem_Standby)

78 78 Chapter 3 Alarms in a Redundant Configuration The following figure shows the distribution of components of the Alarm subsystem in a redundant configuration. The description presented in this section applies for both the Dedicated Standby and the Load Shared configurations. The platforms that host the Visualization clients are configured as InTouch Alarm providers. In order to optimize the network traffic, each platform is filtering alarms for the areas that are of particular interest for that node. Eventually, if alarms from other nodes need to be monitored from a visualization node, this can be accomplished by simply running a specific query for the new node and areas that need to be supervised. The Alarm Database resides in the InSQL node using the MS SQL Server already installed in that node. In this node there is a platform deployed and configured as InTouch Alarm provider. This node does not filter alarms from any area so that it can provide high availability in case any of the visualization clients are not available in the system. The Alarm DB logger is installed in the same node as the Alarm Database. The Alarm DB logger is configured to query all the alarms in the local platform. Visualization InTouch Alarm Provider Visualization InTouch Alarm Provider Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DINetwork DAServer RMC AppEngine 1 (BACKUP) Network Device (Switch or Router ) Historian (Data and Alarms ) Alarm Logger PLC Network

79 Implementing Redundancy 79 Redundant Configuration with Dedicated Visualization Nodes The following figure shows alarm configuration with dedicated visualization nodes: Visualization InTouch Alarm Provider Visualization InTouch Alarm Provider Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DINetwork DAServer RMC AppEngine 1 (BACKUP) Network Device (Switch or Router ) Historian (Data and Alarms ) Alarm Logger PLC Network Redundant Pair with No Dedicated Visualization Client Nodes If the redundant architecture consists of two AOS nodes that also run InTouch Software as the visualization client for the system, the Alarm configuration should be implemented as shown in the following figure: Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DINetwork DAServer InTouch InTouch Alarm Provider RMC AppEngine 1 (BACKUP) InTouch Alarm Provider Historian (Data and Alarms ) Alarm Logger Network Device (Switch or Router ) PLC Network

80 80 Chapter 3 Failover Causes in Redundant AppEngines This section describes failover triggers in a redundant AppEngine pair. Forcing Failover It is possible to force a failover in a pair of redundant AppEngines by simply setting the attribute ForceFailoverCmd in the Active engine to "true". This can be accomplished using the ObjectViewer, InTouch Software, an object's script or any other application that has access to this attribute. Use this attribute in a script (with any set of conditions) to trigger a failover. For example, you can monitor the status of other applications on the same machine, hardware devices, etc. and based on that status, trigger a failover to the Standby engine. When a failover occurs, the Standby engine becomes Active and stays in that status unless the system is forced to fail back when the new Standby engine becomes available. In this case, the ForceFailoverCmd can be used to take the Active engine back to the original node. For details on the attributes associated to a Redundant AppEngine please refer to the AppEngine Help files. Communication Failure in the Supervisory (Primary) Network To understand the effects of a communication failure at the Supervisory Network level, refer to the matrix on the following page. It presents the original status of the redundant pair before the failure as well as the cause of the problem and the final condition. The matrix shows the values of two attributes in the AppEngine used to monitor the status of the redundant pair. They are RedundancyPartnerStatus and RedundancyStatus. The attributes (and other key attributes) are included.

81 Implementing Redundancy 81 Considerations The Failover scenarios described in this section refer to topologies where there is at least one more platform besides the two hosting the Redundant pair, i.e. Client/Server configuration. If the topology consists of just two platforms hosting the Redundant pair (Peerto-Peer configuration) a failover does not occur in the event of a communication failure in the supervisory network. Instead, the Redundancy.PartnerStatus attribute is set to Missed heartbeats while both partners synchronize data through the RMC. In this case, the user can execute the failover either manually or via scripting, if required. Visualization InTouch Alarm Provider Visualization InTouch Alarm Provider Supervisory Network AOS (PRIMARY) AOS (BACKUP) AppEngine 1 DINetwork DAServer RMC AppEngine 1 (BACKUP) Network Device (Switch or Router ) Historian (Data and Alarms ) Alarm Logger PLC Network

82 82 Chapter 3. Initial Condition Transition Final Condition Primary Backup Primary Backup Primary Backup SCENARIO 1a Primary Network Connected Connected Disconnected Connected Disconnected Connected Red. Partner Status Standby Ready Missed Heartbeats Red. Status Active Active SCENARIO 1b Primary Network Disconnected Connected Connected Connected Connected Connected Red. Partner Status Missed heartbeats Standby Ready Red. Status Active Active SCENARIO 2 Primary Network Connected Connected Connected Disconnected Connected Disconnected Red. Partner Status Standby Ready Missed heartbeats Red. Status Active Active SCENARIO 2b Primary Network Connected Disconnected Connected Connected Connected Connected Red. Partner Status Missed Heartbeats Standby Ready Red. Status Active Active SCENARIO 3 Primary Network Connected Connected Disconnected Disconnected Disconnected Disconnected Red. Partner Status Standby Ready Missed heartbeats Red. Status Active Active

83 Implementing Redundancy 83 SCENARIO 1 RMC Communication Failure Even though an RMC communication failure does not trigger failover, it is important to know the system behavior in this event: Primary Backup Primary Backup Primary Backup Failure in RMC Connected Connected Connected Disconnected Connected Disconnected Red. Partner Status Red. Status SCENARIO 2 Standby Ready Active Unknown Active - Standby not available Failure in RMC Connected Connected Disconnected Connected Disconnected Connected Red. Partner Status Red. Status Standby Ready Active Unknown Active - Standby not available SCENARIO 1 PC Failures If a power failure occurs on the Active Engine node, the Standby node takes control of the system. The following matrix shows the corresponding status and AppEngine attribute values under different conditions: Primary Backup Primary Backup Primary Backup PC Failure PC Available PC Available PC Available PC Not Available PC Available PC Not Available Red. Partner Status Standby Ready Unknown Red. Status Active Active - Standby not available SCENARIO 1b PC Failure PC Available PC Not Available PC Available PC Available PC Available PC Available Red. Partner Status Unknown Standby Ready Red. Status Active - Standby Not Available Active SCENARIO 2 PC Failure PC Available PC Available PC Not Available PC Available PC Not Available PC Available Red. Partner Status Red. Status Standby Ready Active Unknown Active - Standby not available

84 84 Chapter 3 SCENARIO 2 PC Failure PC Not Available PC Available PC Available PC Available PC Available PC Available Red. Partner Status Red. Status Unknown Active - Standby not available Standby Ready Active Undeploying AppEngines Undeploying AppEngines in a redundant pair may trigger failover. The following description refers to non-cascade Undeploy operation of the AppEngine. Executing a cascade Undeploy operation of the Primary AppEngine undeploys all objects from both engines. The table below describes the expected behavior under the non-cascade condition: Initial Condition Transition Final Condition Primary Backup Primary Backup Primary Backup SCENARIO 1 Undeploy Backup Engine Deployed Deployed Deployed Undeployed Deployed Undeployed Red. Partner Status Red. Status SCENARIO 2 Standby Ready Active Unknown Active - Standby not available Undeploy Primary Engine Deployed Deployed Undeployed Deployed Undeployed Deployed Red. Partner Status Red. Status SCENARIO 3 Standby Ready Active Unknown Active - Standby not available Deploy Primary Engine Undeployed Deployed Deployed Deployed Deployed Deployed Red. Partner Status Red. Status Unknown Active - Standby not available Standby Ready Active Note It may become necessary to relocate a Primary or Backup AppEngine. Ensure relocation is performed at a non-critical time (scheduled maintenance, plant shutdown, etc.), and that Store Forward is not in operation during the relocation process (undeploy, relocate, redeploy). Data loss may occur if Store Forward is operational during the redeploy operation.

85 Implementing Redundancy 85 Dual Communications Channel Failure Consideration A redundant AppEngine system configuration provides high availability in the event of a single communication channel failure. This means that the system will gracefully handle situations where only one communication channel fails at a given time; for example, PC failure, Primary network failure, etc. The RMC's role as a dedicated link to synchronize data and monitor the status of the redundant pair minimizes the chances of failures within the system, since it is a dedicated cross-over cable between two computers and does not carry external data traffic. If the Active AppEngine simultaneously loses the connection to the Primary network and to the RMC, the system reverts to an ACTIVE-ACTIVE state. To recover from an ACTIVE-ACTIVE condition, both connections must be reestablished. The system arbitrates assigning the Active state, so that the Primary server will become Active, regardless of its state before the ACTIVE- ACTIVE condition. It is possible to design the application to handle the ACTIVE-ACTIVE condition. The solution includes scripting and a third component to monitor the status of both engines. For example, a condition script could be implemented in the PLC to monitor the status of both engines and arbitrate which one stays active if a simultaneous failure occurs in the RMC and Primary network. Redundant System Checklist Refer to the following checklist when planning your redundant system: Determine the Redundant System Configuration Evaluate what type of redundant configuration fits better for your system. Both the Dedicated Standby and Load Shared configuration provide a reliable and robust solution; but depending on the process requirements and system architecture, one of the configurations may be more efficient than the other. Complete details on Dedicated Standby Server - No Redundant I/O Server and Load Sharing Configurations are included later in this chapter. Check the System's Alarm Configuration The Alarms in a Redundant Configuration section in this chapter provides detailed recommendations on how to set up the alarm system, including locating Alarm providers, Alarm DB Logger, Alarm Database, etc.

86 86 Chapter 3 Analyze the Expected System Behavior After Failover It is very important to understand how scripts are executed after a failover. The Scripting Considerations section in this chapter explains how scripts behave in a failover condition. Identify what attributes need to be retentive after a failover. Refer to the Checkpointing section for details on the how attributes can be defined as persistent after a failover. Distribute Data Traffic To make the best use of network bandwidth, distribute the traffic coming in and out of the AutomationObject Servers over different networks. For example, the need for data from the control network may be more critical than the data requirements of the supervisory system. Distributing data traffic through separate networks requires the use of multiple network cards in a server. Note Although distributing data traffic through separate networks is not required, multiple NICs are used for optimal communication in the network figures that appear in this chapter. Rename Each Local Area Connection When Using Multiple Network Adapters The operating system detects network adapters and automatically creates a local area connection in the Network Connections folder for each network adapter. Renaming each local area connection to reflect its network eliminates confusion. Add or enable the network clients, services, and protocols required for each connection. When doing so, the client, service, or protocol is added or enabled in all other network and dial-up connections. Tuning Recommendations for Redundancy in Large Systems To ensure seamless failover in "Large" systems (high I/O, high CPU utilization, SCADA System) performance, modify several default Platform attribute values. Note The following information applies to a large, locally distributed topology. SCADA-specific settings are described in "Inter-Node Communications" on page 263.

87 Implementing Redundancy 87 Tuning Redundant Engine Attributes Multiple variables (I/O points, number of Objects, number of Historized attributes, DIObject distribution, etc.) are involved in the detection and execution of a Redundant AppEngine Failover. The following table describes some key Engine attribute values that should achieve better failover performance in small, medium-large and very large system environments. The list corresponds to AppEngine and Platform Editor options and describes some behaviors resulting from incorrect settings. The I/O numbers listed are totals-per-galaxy. Note The Forced failover timeout values ,000 (below) represent the low-high values of a range. Small System AppEngine Editor (Default) Forced failover timeout 30,000 ms (up to ~3,000 I/O) Max. checkpoint deltas buffered Max alarm state changes buffered Standby/Active engine heartbeat periods Maximum consecutive heartbeats missed from Active engine Maximum consecutive heartbeats missed from Standby engine Maximum time to maintain good quality after failure Max. Time to Discover Partner Medium- Large System 45,000 approx. 3,000 I/O 240,000 approx. 40,000 I/O Very Large System 0 N/A N/A N/A 0 N/A N/A N/A Remarks 300,000 ms If setting is too small, forced failover will not succeed. If setting is too large, failure will not be detected in a timely manner ms 1000 ms 1000 ms May be increased to avoid false failovers ~60 Setting this value too low produces false failovers. Setting this value too large results in slow detection of required failover ~60 Setting this value too low produces false failovers. Setting this value too large results in slow detection of required failover. 15,000 ms 120,000 ms 150,000 ms Assuming remote I/O, setting the value too low causes all I/O references to unsubscribe, then resubscribe on failover. The optimum setting ensures that remote I/O references are preserved for failover. This behavior also applies in the RDI Object context. 15,000 ms N/A N/A N/A

88 88 Chapter 3 AppEngine Editor Small System (Default) Medium- Large System Very Large System Remarks Restart Engine when it N/A N/A N/A N/A fails Checkpoint period 0 (Every scan) 20,000 ms (20K I/O) 60,000 ms (40K I/O) Setting this value too low results in high resource usage. Setting this value too high means that if both partners fail, checkpointed data may not be current. Platform Editor Small System (Default) Medium-Large System Very Large System Remarks NMX Heartbeat period 2,000 ms N/A N/A (Platform editor General tab) Consec. number Missed NMX Heartbeats (Platform editor General tab) Failover Services talk between themselves using the RMC and determine the communication status between the two nodes. The status is provided by monitoring Heartbeat attributes. Message Channel Heartbeat settings control the heartbeat intervals; i.e., how often the redundant platforms send each heartbeat through the RMC. Remarks Modifying the Active/Standby Heartbeat Period values makes the Engines more sensitive to network failure. Missed Consecutive heartbeats determines the number of missed heartbeats that will trigger the redundant engine to act. Setting the values smaller makes the engines more sensitive to network failure. Setting the values larger makes the Engines more tolerant of high CPU loads that can cause missed heartbeats. The values can all be set using the IDE or the Object Viewer. Engine Monitoring The following information describes how the failover service monitors the redundant engines. In general, an Engine has the following states: Start Up: Measured as the time required for all engine objects to be created, initialized and started. Execution: Measured as the time required for all Engine objects to be executed in one scan cycle. Shut Down: Measured as the time required for all Engine objects to be stopped.

89 Implementing Redundancy 89 The following parameters determine how much time the Engine can be unresponsive during each of the above states. Start Up and Shut Down If you experience improper Platform shut down (from the SMC), two solutions are possible: Increase RAM: Increase the RAM to 2GB. Tests have shown that increasing RAM can help provide proper shutdown. Modify Registry Settings. To add the registry settings The default registry settings are not accessible. However, they can be added/changed at the following location: [HKEY_LOCAL_MACHINE\SOFTWARE\ArchestrA\Framework\Platform] 1. Enter the following values: "WatchdogStartupTimeout"=dword:000493e0 "WatchdogShutdownTimeout"=dword:000493e0 The default view for the time values is Hexidecimal. 2. Change the format to Decimal and ensure the setting is ms. (5 minutes in this example) or larger. This should be sufficient for a large system. Setting the values too high could lead to delays in discovery that the Engine has hung/crashed during startup or shutdown, since the Bootstrap considers the Engine healthy until the timeout expires. Note If the WatchdogStartup- and ShutdownTimeout values are modified, they must be reset after the Platform is undeployed and redeployed. Execution The EngineFailureTimeout attribute determines how long that Engine has to inform the Bootstrap that it is executing. If the Engine does not signal the attribute for 3 consecutive timeouts, the Engine is determined to be "in trouble," and the redundant partner takes action. Setting this attribute value too low causes the redundant partner to overreact when CPU usage is high. Setting the value too high can delay notification that the Engine is in trouble since the Bootstrap considers the Engine "healthy" until the timeout expires. Recommended Attribute Name Default Value Value EngineFailureTimeout 10,000 ms. 20,000 ms.

90 90 Chapter 3

91 Integrating FactorySuite Applications 91 CHAPTER 4 Integrating FactorySuite Applications This chapter describes integrating FactorySuite software applications within the Industrial Application Server environment. Specific application requirements drive the integration strategy. The following information provides Wonderware application integration guidelines, and is based on product integration testing. Important! Check the FactorySuite A2 Compatibility Matrix on the FactorySuite support website before starting a project that integrates multiple Wonderware software applications. Contents IndustrialSQL Server Historian ActiveFactory Software InTouch HMI Software SCADAlarm Event Notification Software Alarm DB Manager SuiteVoyager Software QI Analyst Software DT Analyst Software InTrack Software InBatch Software Third Party Application Integration

92 92 Chapter 4 IndustrialSQL Server Historian IndustrialSQL Server Historian integrates with Industrial Application Server using the Manual Data Acquisition Service (MDAS). Historized Attributes are easily configured in the IDE. During run-time, their values are "pushed" to the Historian Node and stored there using the MDAS service. Industrial Application Server provides extensive diagnostics to monitor the operation of the historian functionality, i.e.: store forward status, historian connection, etc. The Historian node does not require a Platform. Note Industrial Application Server 2.1 requires an IndustrialSQL Server Historian upgrade to version 9 or later. For information on how to configure a platform/engine for history or to configure objects to store history, see the IDE documentation for Industrial Application Server. For information on using IndustrialSQL Server Historian with Industrial Application Server, see Chapter 8, "Historizing Data." For information on configuring the IndustrialSQL Server Historian node, see the IndustrialSQL Server Historian documentation. ActiveFactory Software ActiveFactory Software is Wonderware's IndustrialSQL Server Historian Client Application Suite. ActiveFactory ActiveX controls are "rich" clients and require certification permissions by IT Admin or wwadmin-level permissions on the client machine. It is necessary to manually enable TCP/IP- Named Pipes protocols in the Windows Firewall when using Windows Server 2003 SP1 or XP Professional SP2 as web clients. This configuration is not an issue when using the HTTP protocol. ActiveFactory Reporting Website Two installation options are available for the Reporting Web Site client: A. Run an MSI setup on the browser client (requires local administrator privilege). B. Have a domain administrator authorize.net controls signed by Invensys via Active Directory policy settings (version 9.1).

93 Integrating FactorySuite Applications 93 InTouch HMI Software InTouch HMI Software is the visualization component of the FactorySuite A2 System and provides a completely integrated graphical interface for Industrial Application Server. InTouch Software 8.0 or later acquires Galaxy data via the built-in "Galaxy" access name, which uses Message Exchange (MX) and the local Platform. InTouch Software enables easy and powerful browsing of the Industrial Application Server namespace for simplified use of object attributes in InTouch Remote Tag References. Traditionally, InTouch Software developers use windows and scripts to provide functionality such as alarms, history, security, and I/O. When InTouch Software is used as the graphical user interface (GUI) for Industrial Application Server, these features are instead provided by the AutomationObject Server node(s). WindowMaker, WindowViewer, and View WindowMaker is the InTouch Software windows and script development environment. The Bootstrap and the IDE must be installed on the InTouch Software node running WindowMaker in order to browse the Galaxy namespace. Although WindowMaker is provided with a FactorySuite A2 System development package that also includes the IDE, they are totally independent. The IDE cannot be used to develop InTouch Software applications, and WindowMaker cannot be used to create Domain objects. WindowViewer is the run-time environment that displays Galaxy data in the windows created with WindowMaker. InTouch View is a version of WindowMaker designed to connect InTouch Software to the Industrial Application Server only. For an InTouch View application, no access names other than "Galaxy" can be used. No historical logging or alarming is performed within InTouch View, but it can be used to display alarms generated by objects in an AppEngine. InTouch View nodes use Industrial Application Server security through the Archestra IDE security model. For information on using InTouch Software with Industrial Application Server, see the white paper InTouch/IAS Migration and Coexistence Planning Guide on the FactorySuite support web site: InTouch SmartSymbols The InTouch SmartSymbol Manager allows you to create, edit and manage libraries of reusable graphical templates (InTouch SmartSymbols). SmartSymbols can be used to connect to ArchestrA objects and their attributes, and also to local InTouch Software tags or to any InTouch Software remote references. SmartSymbol templates can be associated to Application Object templates and instances, providing a very powerful combination.

94 94 Chapter 4 A common practice is to create a SmartSymbol associated to the attributes of an Application Object template. Once this SmartSymbol template has been created and saved into the Symbol Library, instances of the symbols can be used by dropping them into an InTouch window. These instances can then be configured to point to specific Application Object instances by selecting them using the ArchestrA Object Browser (SmartSymbol Properties panel). Furthermore, the SmartSymbol Property panel allows you to create new instances of a selected Application Object template and associate a SmartSymbol with the new instance. SmartSymbols can easily be redirected to point to other object instances at runtime by using the IOSetRemoteReferences() script function. SmartSymbol Notes The Integrated Development Environment must be installed on the InTouch Development node to use the following SmartSymbol features: ArchestrA Object Browser and Attribute Browser. Create new object instances of a selected template within InTouch WindowMaker. Note Other SmartSymbol features are also enabled when the IDE is present on the InTouch Development node. Creating new instances of an object template using the SmartSymbols property dialog requires the user to have the correct permissions assigned in the Galaxy security configuration. Note For more details on SmartSymbols, the SmartSymbol Manager and the IOSetRemoteRefereces() script function refer to the InTouch Reference Guide. Changes to any Smart Symbol causes recompiling of every window in the application and subsequent re-deployment of all windows. For more information, see "NAD" on page 266. Network Utilization Galaxy references (e.g., references of the form Galaxy:MyObject.MyAttribute) that resolve to remote nodes affect bandwidth utilization, which increases as the data-change rate increases. If your requirement is to minimize network-bandwidth utilization between an InTouch Software node and remote Industrial Application Server nodes, you need to account for all active subscriptions between your InTouch Software node and the remote Industrial Application Server nodes that provide your data.

95 Integrating FactorySuite Applications 95 When any of the following items are configured with a galaxy reference, that item activates a subscription between InTouch View and Industrial Application Server when the following events occur: Launch WindowViewer (with NO windows opened): A. Application "While Running" script. B. Condition Scripts. C. Data-change Scripts. D. Real-Time trend with Only update when in memory unchecked (this is the default). When any window is open; that is, a currently-open window that has: A. Animation links. B. Window "While Showing" scripts. C. AlarmViewerCtrl that is subscribed to the "Galaxy" alarm provider. D. Real-Time trend (regardless of the "Only update when in memory" check box state). For example, assume your application has one window which contains a Real- Time trend with "Only update when in memory" unchecked. Assume this trend is configured to gather data from Galaxy reference "Galaxy:MyObj.MyAttr". Even though that window is not open, InTouch Software has an active subscription and is receiving updates for Galaxy:MyObj.MyAttr. InTouch Software Add-Ins SQL Access Manager, Recipe Manager InTouch Software includes a number of add-ins (sub-systems) that extend its functionality, such as SQL Access Manager, and Recipe Manager. It is possible to implement a similar functionality of those sub-systems directly into ApplicationObjects. For example, Application Objects that execute database queries using ADO.NET can be used to mimic some of the functionality in SQL Access Manager. You can also create an object that stores data into flat files or tables in Microsoft SQL Server and implement logic similar to the InTouch Recipe Manager. InTouch View does not provide access to the SQL Access nor Recipe Manager add-ins, since this functionality can now be implemented in Application Objects using.net.

96 96 Chapter 4 SPCPro Using the SPCPro OLE Automation Library to directly call SPC functions from Industrial Application Server is not recommended. This method requires a very good understanding of the SPCPro database schema, as well as OLE automation. This scenario has not been tested and will not be supported in future releases. Use QI Analyst Software or custom-made objects for SPC analysis within the Industrial Application Server environment. Tablet and Panel PCs Using InTouch Software with Industrial Tablet PCs and Touch Panel computers enables immediate access to process information anywhere in the plant. Tablet PCs Industrial Tablet PCs are furnished with Windows XP Tablet PC Edition and have InTouch Software pre-installed at the factory. A number of wireless options are available. Industrial Tablet PC users can leverage a number of features in both the Tablet Edition of Windows XP and InTouch Software, such as using digital ink (i.e.: to write values into data links or annotate graphical displays), enabling more efficient communication and troubleshooting of problems on the factory floor. Industrial Tablet PCs support a number of options to secure wireless communications, including the use of VPN over wireless. For more information on securing your wireless networks, refer to the white paper "Tablet PCs in Industrial Applications", accessible through the Wonderware FactorySuite support website. Panel PCs Touch Panel computers are shipped with either Microsoft Windows XP Professional or Windows XP Embedded and, in addition to InTouch Software, have selected Wonderware DAServers pre-installed. A pre-installed Industrial Application Server Bootstrap in Windows XP Professional Touch Panel Computers enables fast integration with Industrial Application Server. Both Tablet PCs and Touch Panel computers include the Microsoft Remote Desktop Connection (Terminal Services Client). Using Industrial Tablet PCs or Touch Panel PCs in combination with Terminal Services allows you to install the Industrial Application Server platform and InTouch Software once on a central server and then open sessions from multiple terminals. For information about using InTouch Software with Terminal Services, refer to the Terminal Services for InTouch Deployment Guide on the Wonderware FactorySuite support website

97 Integrating FactorySuite Applications 97 SCADAlarm Event Notification Software SCADAlarm Event Notification Software provides an alarm notification service via pagers, phone, and . While an InTouch Software node could query alarms generated by objects in the Industrial Application Server and act as a gateway to SCADAlarm via remote tag references, the recommended approach is to use SCADAlarm to map directly to an object attribute. To accomplish this, add a server definition in the SCADAlarm configuration that points to the "Object.Attribute" from which you want Alarm notification. SCADAlarm Event Notification Software 6.0 SP1 allows browsing the Galaxy namespace. SCADAlarm Event Notification Software typically reads a string value of 1 in order to determine an alarm condition. This value may be received from the Industrial Application Server as " ," so you should use this string in the tag definition. Acknowledgements can be sent from SCADAlarm Event Notification Software back to the Industrial Application Server via another "Object.Attribute" reference to the.ackmsg. In this case, a string value of 1 is sent to acknowledge the alarm. Note This information applies to SCADAlarm Event Notification Software v. 6, SP1 and later. For previous versions, FSGateway is used to achieve integration between SCADAlarm and Industrial Application Server. Alarm DB Manager Alarms generated by ApplicationObjects are stored within the alarm database. The alarm database can be hosted by the Galaxy Repository node (if available all the time), the IndustrialSQL Server Historian Node, or any other Microsoft SQL Server node that has an Industrial Application Server Platform deployed to it and is configured as an Alarm Provider. The configuration of the Alarm Groups (Areas in the Industrial Application Server) should be configured as "Galaxy!Area" where "Area" is the globally unique name of any configured Area ApplicationObject of the Galaxy. SuiteVoyager Software SuiteVoyager is designed as the web portal to any FactorySuite A 2 System data. InTouch Software windows that access Industrial Application Server data can be converted to web pages for display in SuiteVoyager. History and alarms generated by an Industrial Server Application can also be made available via SuiteVoyager. The SuiteVoyager portal node requires a local Platform to be part of a Galaxy.

98 98 Chapter 4 Note SuiteVoyager and MSDE are supported on Windows Server 2003 if default settings are modified: enable Network Access and SQL Server authentication, both of which are non-default settings for the install. For details of overriding the default installation, see the SuiteVoyager User's Guide. QI Analyst Software QI Analyst Software provides statistical analysis of FactorySuite A 2 System data. The data includes real-time InTouch Software data, real-time data from Application Server through FactorySuite Gateway, InSQL (historical) data, or any other ODBC or OLE DB-supported data source. Quality information is collected, analyzed, and displayed through various QI Analyst Software components. The collecting and analysis engines of QI Analyst Software can be accessed and leveraged by Industrial Application Server, thus allowing data to be sent to and read from QI Analyst Software. Process analysis charts are provided through stand-alone QI workstations or through ActiveX controls deployed within InTouch Software or another ActiveX container. Scripting QI Analyst Software calls can be made from within an Application Object. The QI Analyst Software OLE Automation library is called with the CreateObject() function from ApplicationObject scripting. New data rows and values can be stored in the QI Analyst Software database through the object interface. The main difficulty is in the persistence of objects from one script to the next, or from object to object. Object persistence must be managed with the.net global data cache (that is, System.AppDomain.CurrentDomain). For more information, see "Scoping Variables" in Chapter 5, "Working with Templates,". Setting objects such as a QI database or data table to the global memory allows other scripts to continue working with the object in the same state as the previous script stored the object. DT Analyst Software DT Analyst Software collects, analyzes and displays downtime and efficiency data using the following components: Configuration Manager: Configure the Downtime Database. Logic Manager: Monitor changing tag values. Event Monitor ActiveX Control: Display Downtime Events DT Analyst Software requires its own list of tags. The tagscan be configured to read from I/O Servers, DAServers/OPC Servers, InTouch Software nodes, or the FactorySuite Gateway. Virtual tags (those with no I/O access name) can also be configured. These tags cannot read Application Objects directly from Industrial Application Server.

99 Integrating FactorySuite Applications 99 FactorySuite Gateway DT Analyst Software is integrated with Industrial Application Server environment by using FactorySuite Gateway. The DT Analyst Logic Manager is configured to read from FactorySuite Gateway, which acts as a SuiteLink Server or OPC Server to provide Galaxy data to any SuiteLink or OPC client. Refer to the FS Gateway documentation for further details. The DT Analyst Logic Manager does not require a Platform because it relies on SuiteLink and OPC to receive value changes from I/O Servers. Important! The DT Analyst Logic Manager and Event Monitor require a connection to the Downtime Database (DTDB) in order to be functional. Best Practice Install the DT Analyst Configuration Manager on an Engineering Station node, along with the Integrated Development Environment (IDE) and InTouch WindowMaker. The configuration, downtime, and efficiency data is stored in a SQL Server database called DTDB (default). DTDB is independent of the Galaxy Repository database and the objects that it contains. Aspects of the DT Analyst Software process model (such as Systems, Areas, or Groups) may be similar to some objects in Industrial Application Server, but they are not directly related. However, it is possible to query the DTDB database from an object designed for that purpose. InTrack Software InTrack Software is the Work-In-Process (WIP) and Material tracking component of FactorySuite. It delivers configuration tools, OLE COM objects, and database structures that manage the movement, creation and consumption of materials as they move through the manufacturing process. InTrack Software requires either Microsoft SQL Server or Oracle database to function. For specific database requirements and important planning guidelines, refer to The InTrack Deployment Guide. Using InTrack Software with an Application Server Industrial Application Server provides an opportunity to enhance and extend the core capabilities of InTrack Software. Industrial Application Server can serve as an event source to trigger InTrack transactions, and can perform conditional alarming or execute pre-conditioning logic or qualification for InTrack Software calls.

100 100 Chapter 4 All IAS attribute tracking capabilities - alarming, historization, and I/O source definition - can be applied to the execution of objects pertaining to InTrack Software interaction. The two components, Industrial Application Server and InTrack Software, must be closely coordinated through naming conventions and structure to accomplish this coexistence. The following section provides guidelines for successful implementation. IAS and InTrack Software Implementation Guidelines Use the following strategies when implementing InTrack Software within the IAS environment: Execute InTrack method calls from Industrial Application Server objects, either via scripting or embedded into objects that are built using the Application Object Toolkit. The TrackOBJ.dll can be imported into the Industrial Application Server galaxy and any object that references the library will have the required methods deployed to its platform. Only one connection to the InTrack Database can exist on any platform, so an engine-level object must be created to manage this connection. Error handling must occur within the calling scripts. The scripts may execute synchronously or asynchronously but, since database response can be unpredictable, care must be taken to accommodate execution of the Industrial Application Server scan. As a rule, scripts that execute any DB transaction should not run synchronously in a scan that includes time-sensitive control objects. Allowing this exposes the application to scan overruns and/or lock up. While it is conceivable that one could segregate all InTrack scripting functions to a dedicated engine and simply ignore scan overruns, it is rarely possible to construct an Industrial Application Server object model that lends itself to this architecture. Executing the scripts asynchronously from within IAS spawns a new thread which executes independently and does not interfere with scan execution by waiting for a response. The developer must include a message identifier to ensure that responses are directed back to the appropriate client. Another method involves creating a transaction server that abstracts the Industrial Application Server objects from the InTrack COM libraries. This transaction server is essentially a piece of code that creates and processes InTrack calls. An object executing on an AutomationObject Server platform collects attributes that are required input parameters for InTrack methods (for example, TransID, LotID, Quan, and so forth), packages them, and, on a defined trigger, sends them to the transaction server. Delivery of the packaged parameters can be accomplished via Web services. The Web service handles message quality and integrity. The transaction server unpacks the parameters and assembles them into appropriate COM method calls. These calls are executed against one, or a pool of several, TrackOBJ library(ies) on a central server. This strategy effectively moves the creation and execution of the COM calls to the backend server.

101 Integrating FactorySuite Applications 101 The transaction server can be run on the same server as the database or separately. For larger customers or a high traffic network, you might have three separate servers: the Application server, transaction server, and DB server. A Web server on each side handles taking attributes from the object, sending them across the network, and delivering them to the transaction server. InTrack Software Integration with Other FactorySuite Software InTrack Software can be combined with other FactorySuite software applications. InTouch Software is used to develop run-time applications, and to host the visualization and logic for InTrack Software. InTouch Software resides on the client side, either through direct connection or through a terminal. For applications with many interface graphics and straightforward InTrack code, using InTouch Software as the OLE Automation container enables faster development. If the InTrack scripting is complex and the User Interface simple, Visual Basic is faster and offers more debug options. InTrack Software may also be combined with additional FactorySuite A2 System components, like InSQL, SPCPro, and InControl Software. Applications using InSQL should use SQL Server for database management. The InSQL and InTrack databases can reside on the same or separate servers. If either database will have a high transaction rate, the use of separate servers is recommended. SPCPro is Wonderware's statistical control product. When using SPCPro with InTrack Software, use SQL Server for database management. One InControl engine can manage multiple InTrack Software transaction engines. The InControl engine accepts commands from multiple client applications and determines which transaction engine is available for executing the command. All results, processing time, and errors are returned to the calling client application. Although InTrack Software is not integrated with SQL, use Industrial Application Server attributes or inputs from machine level devices to InTouch Software tags as triggers for InTrack Software events. For example: A Start button can trigger attributes collection and send a call across the Web service to the InTrack Software function.

102 102 Chapter 4 InBatch Software InBatch Software is flexible batch management software designed to power production of any batch process. InBatch Software includes several SQL databases. The Material database and the Recipe database are the most relevant in the context of IAS. For example: It may be necessary to modify the amount of one ingredient added based on the concentration of another ingredient. InBatch data is accessed using an OLE Automation server. The OLE Automation Server is called, and passed a list of "fill-in-the-blank" values indicating what data you want. The object then exposes the data in a group of fields. Having only Discretes, Analogs and Strings, InTouch Software lacked the proper data types to support access to these databases through its QuickScripts. Users were forced to write their own VisualBasic or C code to access these files. With the release of Industrial Application Server, the datatypes supported by the UserDefinedAttributes of an IAS object contain the necessary datatypes to access the Batch data. This means that a object can be built with UDAs that correspond to every attribute of the OLE automation object. Include the proper values into each UDA to define what transaction to make with the OLE server. The script is used to "Fill-in-the-blanks" through the UDAs and then trigger a different UDA linked to a method of the OLE Server. The requested data goes into a different set of UDAs to be read or fed into other objects. InBatch Objects enable the ability to interface with data retrieval objects that previously required the knowledge of higher programming languages; i.e.; VB or a C variant. Industrial Application Server can be used to extend InBatch Software's functionality by performing the following tasks: Monitor and handle the use of Batch Units. Monitor and handle material assignment and reception of Material relative to a Batch Unit. Perform Statuses and Material reconciliation. Industrial Application Server Application Objects add scripting capabilities to InBatch Software. The scripting engine and other custom functions make it easy to receive materials and reconcile inventory with I/O values. Synchronize the InBatch Material database with an external database such as PreWeigh and Material Management systems. The Industrial Application Server scripting engine can interact with third-party database and enable customization. Generating real-time, batch-specific alarms. Operating as an external phase engine. Applying run-time formula adjustments.

103 Integrating FactorySuite Applications 103 Use materials characteristics to adjust the target amount of a material. Application Objects make it possible to include material information that the batch system alone does not use. The following Application Objects can be used to extend InBatch Software functionality. BatchProxy object: Uses the DDE/SuiteLinkClient object as basis for a communications channel between Industrial Application Server and InBatch Software; InBatch Software acts as Server BatchUnit Object: Monitors Unit status tags BatchInventory object: Connects to InBatch Material Database by using InBatch's MaterialSrv.exe COM server interface, can be used as a contained object for any BatchUnit object instance to monitor Materials and for other actions such as Material reconciliation BatchPhase Object: Enables Industrial Application Server to run external phases Note FS Gateway must be installed first; InBatch Software acts as a client. Information on installing and using Batch Server objects can be found at the For additional InBatch Software information, refer to InBatchCOM.pdf. InBatch Production System Requirements InBatch Software is supported on Windows 2000 Server and Windows 2003 Server operating systems. Note XP Pro CAN be used on an InTouch Software node that is serving as an InBatch Software client or an IAS visualization node. The InBatch Info Server option (which is the historian part of InBatch Software) and an IAS GR node require the installation of MS SQL Server. Installing MS SQL Server on non- Server operating systems is not supported by Microsoft or Wonderware. An InBatch production system requires two or more machines: an InBatch Software server on one computer, and Industrial Application Server on another. Also, each InBatch system contains at least one Batch client. More complex systems may include a Redundant Server for automatic backup, InTouch Software clients, AutomationObject Servers, and a Terminal Server with associated Batch clients. Batch clients can be used for development, runtime production, report development or web-based reporting.

104 104 Chapter 4 InBatch Software and Industrial Application Server with Windows Server 2003 Windows Server 2003 (Standard Edition) comes with many security settings which, unlike former Windows Server operating systems, are disabled by default. In order to access a Windows Server 2003 machine remotely, you must enable the appropriate security settings. Note For details on FactorySuite A 2 security, see "Securing FactorySuite A2 Systems" on page 200. Using DCOM in a Workgroup environment requires a common administrator account on both the server and the client machine. Furthermore, to use DCOM from Industrial Application Server scripting, this account must be the same account that was used when installing the server and requesting an account. Refer to the FactorySuite A 2 support site for information on DCOM settings for InBatch Software. InBatch Production System Topologies InBatch Software/Industrial Application Server combinations are deployed using one of two topologies. The following descriptions explain what kind of information is exchanged. InBatchServer The first topology, BatchServerSuiteLinkClient/IBServ uses the DDE/SuiteLinkClient Object. InBatch is the server, Industrial Application Server is the client. This topology is recommended for batch engine information, batch information, and equipment allocation. The BatchServerSuiteLinkClient/IBServer topology provides the following advantages: InBatch Unit system tags can be used by Industrial Application Server through BatchServerSuiteLinkClient Object. New unit attributes can be created for InBatch data (also available through COM interfaces). InBatch COM servers can be used within Industrial Application Server scripting. Industrial Application Server scripting can be used to write one object, then instantiate many. Industrial Application Server AppObjects can be used to generate alarms. For example, "Phase Execution Time Exceeded on a Specific Unit."

105 Integrating FactorySuite Applications 105 The following topology figure illustrates the InBatchServer topology: Batch Server: IBServ Industrial Application Server : SuiteLink Client/FSGateway SuiteLink InBatchClient The second topology, FS Gateway/IBCli, a unit or phase topology, uses SuiteLink Protocol. Industrial Application Server is the server, InBatch is the client. This topology is recommended for Industrial Application Server scripting and field I/O data, (such as phase information, equipment status). The FS Gateway/IBCli topology: Exposes phase logic attributes in Industrial Application Server to InBatch Software through FS Gateway. Phase logic in Industrial Application Server is more flexible than PLC database/file access, Also 3rd party systems interface, more intelligent alarming. Can be combined with PLC logic for added intelligence and parameter adjustment. Batch Server: IBClient Industrial Application Server : SuiteLink Client/FSGateway SuiteLink

106 106 Chapter 4 Third Party Application Integration FactorySuite Gateway FactorySuite Gateway (FS Gateway) is a universal translator, capable of translating all major protocols (MX, OPC, DDE, SuiteLink) to any protocol required by a network component. Use FS Gateway to translate between Archestra MX protocol and other protocols. For example, an Industrial Application Server, which uses MX, could not (previously) be accessed by third-party clients except though InTouch Software. Excel, Visual Basic, and other third-party applications were unable to receive data from FactorySuite products without using InTouch Software tags. Using FS Gateway as a protocol translator enables direct connection to an Industrial Application Server. FS Gateway can replace OPCLink, which translates OPC to DDE or SuiteLink. FS Gateway is also useful for legacy servers, controllers, and operating systems. Gateway can translate older DDE to the newer SuiteLink protocol, enabling legacy products to connect to newer systems. Other Connectivity/Integration Tools Client Application (Device Integration) Objects Industrial Application Server accesses device data using Device Integration (DI) objects. These DIObjects ($DDESuiteLinkClient, $InTouch proxy, $OPCClient) enable the server to interface with I/O devices that use DDE, SuiteLink, InTouch Software tags, or OPC protocol. Other protocol connectivity tools include third-party OPC servers, the Archestra DAS Toolkit, the Rapid Protocol Modeler Kit, the ActiveX SECS- II/GEM kits, and the InTouch Tag Creator. I/O Servers I/O servers provide connectivity for devices using DDE, FastDDE, and SuiteLink protocols. I/O servers can connect every FactorySuite 2000 and FactorySuite A2 System component, as well as PLC, RTU, DCS, and ESD systems. Build I/O servers using Wonderware's Rapid Protocol Modeler (RPM) Kit. The RPM Kit can handle both serial and TCP/IP communications with either ASCII or binary protocols to connect FactorySuite client applications to devices with non-standard protocols.

107 Integrating FactorySuite Applications 107 DAServers DAServers (Data Access Servers), provide simultaneous connectivity between plant floor devices and DDE, SuiteLink and/or OPC-based client applications running under Microsoft Windows. The DAS Toolkit allows you to create a DAServer specific to your needs. DAServer architecture is modular, allowing for plug-ins for DDE/SL, OPC, and other protocols. Production Events Module (PEM) The Production Events Module (PEM) is an ArchestrA-based Functional Module designed to provide traceability of production events. The module consists of a set of ArchestrA application object templates and associated components and services required to capture, store and report production event data. Data Storage is handled by a SQL Server relational database designed following the S95 standards for naming, format, data and transactions that occur between Production and Business Systems. Basic built-in reporting features are made available via a PEM Content Unit for SuiteVoyager and a number of Production Database views are made available for end user custom reports. PEM integrates with IndustrialSQL Server Historian and SuiteVoyager. In order to provide store and forward capability, the PEM functional Module leverages Microsoft's Message Queue to handle event messages when PEM objects are configured "without response" - between AOS nodes where the PEM objects reside and the production database node. The basic recommendation when integrating PEM into an application is to develop your ArchestrA model first. Then identify the data that needs to be collected: the process segments, the triggers associated to production events, the identifiers that link these data (lot, production request, etc.) and the points in your model where the PEM objects need to be placed before adding the corresponding PEM objects. Like any Application Object, PEM objects can be extended. PEM objects provide for the configuration of "Extended Production Attributes" to capture additional custom attributes when an event is triggered. The modular nature of PEM enables system scalability allowing growth from small pilot or limited solutions to much larger systems. Note For more detailed information on the PEM Functional module see the PEM User's Guide. For recommendations on how to properly integrate PEM objects in your ArchestrA application, best practices, tips and troubleshooting recommendations, see the Production Events Module v. 1.0 (PEM) Deployment Guide.

108 108 Chapter 4 InControl Software InControl Software enables connectivity to third-party OPC servers and clients by creating an OPC Server and/or an OPC client. Use the OPC interface set to collect and transfer data between software packages from any vendor. InControl Software's OPC Server consists of these three primary types of objects: server, group(s), and item(s). Each OPC item object represents a single data element in the data source and has a name, value, time stamp, and quality. Items also have attributes and properties. OPC groups manage the attributes of each item contained in them. The OPC server maintains the properties of all OPC items. The InControl OPC server uses SuiteLink for communications. Note OPC uses the client-server model and the Microsoft COM/DCOM protocols for vendor-independent data transfer. SQL Server Use SQL Server Linked Server functionality as a gateway to systems using Oracle, Sybase, Ingres and other databases. Once linked to SQL Server, external databases operate as if they were part of the native SQL Server database. Data from multiple databases can then be combined in reports and queries. See the FactorySuite esupport website, especially the Compatibility Matrix, for more information on specific component combinations.

109 Working with Templates 109 CHAPTER 5 Working with Templates A "template" object represents common functional requirements of a field device (valves, pumps), a group of field devices (skids, stations), or a user function (algorithms). These requirements reflect information such as number of Inputs and Outputs, alarm conditions, history needs, and security. One template object performs the equivalent functions of multiple InTouch tags and scripts. A template-centric development practice enables re-use of existing engineering. This chapter includes recommendations for using templates in the IAS environment. Contents Before Creating Templates Creating a Template Model Using UDAs and Extensions Deriving Templates and Instances Re-Using Templates in Different Galaxies Export/Import Templates and Instances Scripting at the Template Level

110 110 Chapter 5 Before Creating Templates Before building templates, identify and document the functional requirements of the target field device. To accomplish this, the following tasks must be completed: Identify all required field device properties (attributes). They include names, data types, and interaction requirements (that is, none, input, output, or input/output). For each attribute, determine if: The attribute requires scaling or uses raw values. The attribute requires alarms, and the alarming model to be used by each. This model can include where the alarms will be generated (locally or in the control system), any alarm priority assignment, and alarm messaging needs. The attribute requires security and the security control. The attribute requires historical logging. For example, is forced data storage required? For a variable data type, do you need to define the trend limits and a deadband? Identify any required scripting, such as algorithms, interaction between devices, and so on. Determine if field devices are grouped either into a common template or into a containment template model. It is not necessary to know all requirements before building a template model. Extra functionality can be easily implemented in the template when new requirements are determined. Creating a Template Model After generating and documenting field device requirements, decide on a template model that fits those requirements. Begin by reviewing the field devices and their requirements, while looking for commonality across similar field device types. Determining this commonality is the basis for developing the template model. Select a Base Template that provides a logical foundation for the device type. For example, valves, pumps, and motors that have multiple states based on discrete limit switches use the $DiscreteDevice base template. Pressure and level switches use the $Switch base template. Process variable transmitters and controllers use the $AnalogDevice base template. Finally, basic process data receivers use the $FieldReference base template. A template is created either from a base template or from another derived template. Base templates are the objects provided with the Industrial Application Server. Base templates cannot be modified. Never create instances directly from base templates, since you will not be able to take advantage of advanced configuration and maintenance capabilities.

111 Working with Templates 111 Four Object Editor tabs are used for configuring the template: The Object Information tab contains basic configuration information, object execution order, and a Help file link. The Script, UDA, and Extensions tabs are discussed in more detail in the following content. After creating a derived template set, create sets of complex template instances. The derived templates become the basis for all other instances. This derivation practice is called containment. Containment vs. UDAs Using containment or UDAs as the best configuration approach depends on actual field device requirements. For example, template containment works best when the lower level object also has many components and may contain even lower-level objects. Similar functionality can be achieved using User-Defined Attributes (UDAs). However, when the lowest level object is added to a template, it may be done using either template containment or UDAs. Both support an external I/O point link and history. Use the following guidelines to expedite an appropriate development strategy: Use Template Containment when more functionality is required, such as complex alarms, setpoints, I/O points, or other features readily available in a template. Use UDAs when lower-level object is very basic. Use the UDA for memory or calculated values. It is also valid to always use a contained object for consistency, even when the property is very simple. Decide the appropriate approach in advance of implementation. Best Practice Ensure the container incorporates functionality; otherwise place it as an attribute in another object. Do not use excessive empty containers simply as placeholders to host objects. Empty containers impact engine scan resources and time. There is no practical limit to the number of attributes-per-object. However, strive to keep the actual object count down. Deeply-nested template/container structures slow down change check-in and propagation. Complex objects should be built using UDAs, scripts and containment. If additional performance is required, first try compiling the object scripts into.dlls to streamline scripting. The form supported by Industrial Application Server is a.net Library and can be created using Visual Studio.NET with either Visual Basic.NET or Visual C#.NET.

112 112 Chapter 5 Note Information specific to the.net environment is included in Chapter 6, "Implementing QuickScript.NET." If further performance is needed, use the Application Object Toolkit to create custom templates. Base Template Functional Summary The following information describes each base template object and recommendations for use. $AnalogDevice Template The $AnalogDevice Template object provides supervisory control capabilities for instruments or equipment that have a key continuous variable. It contains numerous features to model more complex analog inputs and control loops. Any analog value that requires I/O scaling or alarming must be derived from this base template. The General tab of the Object Editor includes a field for setting the type of analog device. The Analog option type enables configuring a Process Variable (PV) input source and (optionally) a different output destination. The PV can be scaled, multiple alarm points defined, and history collected for the PV. The Analog regulator option type allows for a PV input (no separate output), a setpoint, an optional different setpoint feedback address, setpoint high and low limits, and optional control tracking. It also supports scaling, alarms, and history. When the analog device is configured as an Analog regulator, many aspects of a PID loop can be defined. It is necessary to add User-Defined Attributes to access specific loop control parameters, such as controller gain, integral time constant, etc. A fully-functional loop simulation object (based on the $AnalogDevice template) and other $AnalogDevice Objects are available for download at $DiscreteDevice Template The $DiscreteDevice Template object provides supervisory control capabilities for instruments or equipment that have two or more discrete states. Use the $DiscreteDevice template for creating objects that monitor multiple discrete inputs and map them to a state table. A simple example is two discrete values representing an Open limit switch and a Close limit switch. Four options exist for the open and close options, and could be represented by the states Open, Closed, In Transition, and Fault. The Process Variable (PV) attribute of the discrete device is a string representing the state. This can also be read as an enumerated integer value. The object supports up to five distinct states based on one- to four inputs. Up to six discrete outputs are available from the template.

113 Working with Templates 113 The Passive state is provided to represent the state when the field device is not energized. For example, a valve that fails to the closed state when it loses power would have a passive state of Closed. A valve that requires power to command it to open and to close may only use the two active states and not have a passive state. Alarms can be generated for either of the two active states or the fault state. The object also includes the option to record statistics, such as the duration of the various states, and to alarm on the duration. $FieldReference Template The $FieldReference Template object provides simple I/O capabilities for an external data source, including field instruments, for a variety of datatypes. The $FieldReference template is the parent for $Boolean, $Double, $Float, $Integer, and $String templates. These templates provide a mechanism to read and/or write to single I/O points in the field and to collect history on the process variable. The $FieldReference template does not provide scaling or alarm limits. Use the $AnalogDevice template for scaling I/O and setting alarm limits. The field reference templates are basically the same as adding a user-defined attribute and using the extensions to add input, output, or history. $Switch Template The $Switch Template object provides simple I/O capabilities for a single, two-state discrete signal. The $Switch template provides slightly more functionality than the $Boolean template, but less than the $DiscreteDevice template. The $Switch template provides two text states for a single I/O point (with an optional different output address). The value can be stored in history and either state (On or Off) can be alarmed whereas an alarm extension only alarms on the TRUE state. $UserDefined Template The UserDefined object provides an empty starting point for creating custom built objects that include UDAs, Scripts, Extensions, or Contained objects. The UserDefined ApplicationObject enables the user to define the following Analog and Digital inputs: Analog Inputs: Scale raw values Define Deadband Define alarm levels Define deviation alarms Define Bad PV alarms Define Rate of change alarms Define primary and secondary engineering units

114 114 Chapter 5 Generate events on value change Provide statistics Discrete Inputs: Assign On/Off Messages as labels. Define alarm states as On or Off condition Invert input value Provide statistics Template Modeling Examples The following information describes two template modeling examples: Example 1 This example describes the model of a process that contains four discrete valve types. The valve types are determined from device requirements. To optimize engineering development, a common derived template called $DValve is developed (from the $DiscreteDevice base template) that contains all the shared discrete valve requirements. A template for each discrete valve type is derived from that common template. The following figure illustrates how these templates are developed: Base Template $DValve Discrete Valve $SDValve Single Actuator Valve without Feedback $SDValveSF SingleActuator Valve with Feedback $SDValveDF Single Actuator Valve with Dual Feedback $DDValveDF Dual Actuator Valve with Dual Feedback Use this practice to model valves on different manufacturers and their models. A base valve template contains the fields and settings common to all valves within the facility. A new template is then derived from the base valve template for each manufacturer and contains vendor-specific settings. Finally, a new template set is derived from the vendor-specific template for each valve model used in the facility. Once a model-specific template is available, instances will be derived from the template to represent the actual valves.

115 Working with Templates 115 Example 2 This example describes a common, complex relationship called Reactor. Reactor is based upon an interaction of five field devices. Multiple instances of this relationship are used within the plant model. The relationship can easily be developed using containment. Create a derived template called $Reactor from the $UserDefined base template. Then, create template instances representing each of the five field devices. The complex relationship can now be developed (using scripting) in the container object ($Reactor) using the hierarchical names given to each field device. When instances of $Reactor are created as field devices, each has two names: the containment name (hierarchical name); and the physical name. The following figure illustrates this practice: Derived Template with Containment $Reactor $UserDefined Template Inlet $DDValveDF Dual Actuator Valve with Dual Feedback Outlet Temperature $Analog Standard Analog Level InletPump $Pump Standard Pump

116 116 Chapter 5 Using UDAs and Extensions A User-Defined Attribute (UDA) enables data type additions to the template or instances. UDAs can be further enhanced by extensions. Using extensions, a UDA can take on input, output, history, and alarm characteristics. UDAs are categorized as follows: Calculated: The UDA is only modifiable by the instance. It will have no initial value until the object writes to it. Calculated UDAs are typically used for totals, averages, and so on. Object Writable: The UDA is writable only by instances within the Galaxy. User Writable: At run-time, the UDA is writable by a user (subject to security restrictions), other instances, and the configuration program. Note Locking a UDA makes it a Constant and therefore, it is not writable at run-time. Best Practice When defining UDAs with input or output extensions, never lock their source or destination within a template, since it will be unique to each instance and defined later. Use three dashes ( --- ) to represent an unknown reference. This prevents the "could not resolve reference" warning when instances are created. User-defined attributes may have a one-dimensional array. Arrayed UDAs cannot be extended. Only a Boolean UDA can take on alarm extensions. Make the proper selections of priority, category, and whether the template description or a unique message for this alarm is to be used. Alarms on analog values require use of an analog device template and object containment. For a Boolean or Analog UDA alarm that comes from the field device control logic and requires a corresponding Acknowledge, the "Acked" attribute should take on an output extension with the destination being the "Ack" point in the control logic. If an underscore ( _ ) is the first character of an attribute name, that attribute is hidden from users at run time. Use this hidden attribute when you need variables to support certain functionality, but want to hide them from users in order to prevent confusion. A hidden attribute cannot be extended. Any UDA and its extension created within a template is inherited by all derived objects. However, attributes and extensions are only propagated when the instance is created or when that particular attribute is locked.

117 Working with Templates 117 Most UDAs are checkpointed. This means that all data necessary to support automatic restart of a running Application Object is saved periodically. The restarted object has the same configuration, state, and associated data as the last checkpointed value. Unlike other UDAs, Calculated UDAs are not checkpointed. However, a "Retentive Enabled" Calculated UDA is available and can be configured to be checkpointed with all the other attributes in that object. Note For details on checkpointing, see "Checkpointing" on page 74. Deriving Templates and Instances The following information describes effective implementation practices for template and instance derivation: Best Practice Derive from the Base Template First: Derive a template from the base templates before deriving any instances. An object instance that is derived from one of the base templates ($AnalogDevice, $DiscreteDevice, $FieldReference, $Switch, $UserDefined, $WinPlatform, $AppEngine, and $Area) cannot be modified at the template level in the future to add additional scripting, UDAs, and so on. Therefore, always derive a new template from the base templates, even if it is identical to the base template. When a template is derived from another template, the derived template inherits all of the characteristics of the parent template. If the parent template is modified, only the attributes and extensions that are locked will propagate to child templates. Propagate Security: Changes made to the security control of any attribute or extension will not propagate. If new attributes, scripts, and extension are added, they always will propagate. The derived template can then take on additional functionality. When an instance is derived from a template, changes made to the security control of an attribute will propagate, but changes made to the security for an extension will not propagate. If you deploy instances of a template and then modify the template, you will then need to re-deploy the instances. Before deploying changes, you may want to perform an upload of runtime changes. The upload overwrites the initial attribute values with current run-time data. Lock Attributes: Use Locking to propagate functionality when modifying a template. You can then unlock the attributes and extensions when the propagation is complete.

118 118 Chapter 5 Name the Object: When an instance of an object is first created, it is given a default name based on the parent template name and an incremental number (_XXX). The name should be changed to meet the naming convention established for the project. If the instance is contained by another object instance, it will also have a hierarchical name. Note The object's instance name is used by IndustrialSQL Server Historian to store historical data (not the hierarchical name). It is important to properly name the object before it is deployed. Each name can contain up to 32 characters. The object hierarchy can be up to 10 levels deep for a maximum hierarchical name of 329 characters. In the case of creating large numbers of instances from a single template, see the following section regarding Galaxy dumps and loads for a potentially faster renaming mechanism for a complex compound object. Re-Using Templates in Different Galaxies The following recommendations apply in an environment where separate, unique galaxies exist at different production sites, and where standardization is required across the sites. Templates can be reused in different galaxies (just as they can be reused in the same galaxy) to create multiple instances. The important difference in this scenario is that change propagation in a single galaxy is a simple process where locked features are automatically propagated to instances, whereas a multi-galaxy environment requires formal procedures be defined and implemented to manually update and maintain templates. The following recommendations describe performing updates/synchronization in a structured and repeatable manner: Best Practice Create a Master Galaxy for development purposes. This Galaxy contains the master template library with the latest revisions for all of them. When new galaxies must use any of these templates, ensure they include the latest revisions. Create a "staging" engine for testing purposes. Whenever possible, deploy this engine on a machine that has no impact on a real production system. Once an object design has been tested and its functionality verified, it can be distributed to other sites. Export.aaPkg packages (cab files) that contain the necessary templates out of the Master Galaxy, then import them into the new production Galaxies.

119 Working with Templates 119 Create local templates that derive from the master at each production galaxy. Any changes or specialization required should be implemented in the local template. Make use of toolsets to separate the master templates from the local templates; it is even recommended to hide the master template toolset in the production galaxies and treat them as if they were Read Only templates. Packages with exported templates do not include any logs documenting changes to the base templates, so all changes must be done in the master galaxy and properly documented upon check-in after editing objects. The Import Preferences dialog box (opened when importing a package with templates) includes options to handle version mismatches and name conflicts. In a multi-management environment where a package from the Master Galaxy is updating templates that already exist in production galaxies, select the Overwrite option to handle version mismatch. The Overwrite option will only work if the version of the object being imported is higher than the current version; the object version is stored in the ConfigVersion attribute that is present in all templates and instances. Changes made on the local templates should be verified and validated before they are merged into the master template on the development Galaxy. If it is determined that the features in local templates should be implemented in the master templates, any new functionality (i.e. attributes or scripts) must be manually implemented on the master templates and properly documented. After manual implementation and documenting, a new package can be exported in order to update all production galaxies with the new version of the templates. Export/Import Templates and Instances Use the Export/Import functionality of Industrial Application Server to transfer templates and instances between Galaxies. Two export processes are available: Automation Objects: Best for transferring templates and optionally instances between Galaxies. Galaxy Dump: Best when working within the same Galaxy to create new instances of a template.

120 120 Chapter 5 Export Automation Objects Galaxy Dump When you perform an export of Automation Objects, the following are saved: The selected instances and templates. The templates from which the instances and templates were derived. The toolset used to display the templates. An import simply imports the contents of the export file. A Galaxy Dump exports template instances to a.csv file for editing or for adding an instance of a template. Modifications can be loaded back to the Galaxy. When a dump is performed, any script, attribute, or attribute extension that is not locked at the template level will be dumped, each in its own column. A reference to the parent template is also contained in the file, in order to bring in all of the locked scripts, attributes and extensions. Attributes that are calculated or writable at run time are not dumped. The dump and load functions are useful for quickly creating multiple instances of a template, instead of using the IDE. To prepare a file for a Galaxy Load operation 1. Create one instance of the required template and dump this into a.csv file. 2. Open the.csv file using a spreadsheet editor (Excel). Note Notepad or WordPad are viable options but contain limited functionality. When editing an existing Galaxy dump, perform a search and replace to change all occurrences of object instance names. The Search/Replace operation can also be performed within Excel. Excel does not recognize the file as a.csv formatted file and all the data is displayed in the first column. 3. Select the first column in Excel and "Convert Columns To Text" using delimited and comma as parameters. This places each column from the the.csv file into a different Excel column. WARNING! NEVER click the Save button in the toolbar or the Save option in the File menu. Excel will save the spreadsheet as a.xls file and destroy the formatting conversions. See the following step for saving to a.csv format. 4. After the modifications are done to the file (using Excel), select Save As from the File menu and make sure that the File Type is.csv. The file now has the valid format to successfully apply a Galaxy Load operation from within the IDE. In the following example, five additional instances were created from the $Boolean template.

121 Working with Templates 121 For three of the derived instances, the Area is not known, and for three other instances, the Area is HomeArea: ;Created on: 1/10/2003 2:01:12 PM from Galaxy:Test :TEMPLATE=$Boolean :Tagname Boolean1 Boolean2 Boolean3 Boolean4 Boolean5 Boolean6 5. Save the changes to the.csv file. 6. Load the.csv file into the Galaxy. For this example, the following events occur when the load is performed: The first three instances are created with all template functionality. If no Area is set as the default, the instances appear in the Unassigned folder in the IDE. The next three instances are placed in the HomeArea Area, if this Area currently exists. Otherwise, the objects use the Area settings for the first three instances. The advantages of using the Galaxy Dump and Load over creating instances within the IDE are evident when conforming to a naming strategy. For a contained object with three levels and hundreds of instances, it is much easier to rename all the instances with a search and replace of 101 to 102 instead of naming each instance one-by-one within the IDE. Best Practice Area HomeArea HomeArea HomeArea When backing up the Galaxy database, use the Backup functionality available within the Galaxy Database Manager of the System Management Console. The backup contains all Galaxy information (including security configuration), whereas the simple export of automation objects only includes the object structure and template toolsets.

122 122 Chapter 5 Scripting at the Template Level Add additional functionality to a template by creating scripts. Scripts are written using the QuickScript.NET language. Best Practice The following best practice recommendations are cross-referenced to practical examples described in the following chapter. Segregate functionality by creating unique scripts for each segment required. For an example of modular scripting, see "ObjectCacheExt.DLL Overview" on page 151. When functionality within the script will require an extended amount of time to execute, set the script to run asynchronously with a timeout limit. Such functionality is sometimes required by COM objects and.net objects (for example, file operations, SQL queries, and so on). For an example of Asynchronous scripting, see "$SqlConnCacheMgr Script Examples" on page 158. When creating scripts at the template level, you may want to lock them. You can then make changes to the template script, and the changes will propagate to the next level. When a script is locked and there are no declarations or aliases, these sections should also be locked for improved propagation and deployment performance. When the field devices have a structured containment and addressing convention, create a script that will populate all attributes with an I/O extension at the time of deployment. If instances have been configured using this method, you can use the "Upload Runtime Changes" functionality to synchronize the changes back to the Galaxy Repository. When adding scripts to templates, use relative names (Me, MyContainer, MyEngine, MyArea, MyPlatform, and MyHost). Using relative names saves you from having to edit absolute references in every instance. Lock all inherited scripts, otherwise a copy of each assembly/script will be created for each object derived from the template and multiple copies of the same script will be running on the AppEngine object where they are deployed. Locking the scripts generates one single assembly to be deployed to the AppEngine. The assembly is then shared by all instances derived from that template. Note For more information on scripting and practical examples, see the Chapter 6, "Implementing QuickScript.NET."

123 Working with Templates 123 Script Execution Types The script execution types and when they should be used are as follows: Startup: Called when the object is loaded into memory. Primarily used to instantiate COM objects and.net objects. OnScan: Called the first time an AppEngine calls this object to execute after the object scan state is changed to onscan. Primarily used to initiate attribute values. Execute: Called every time the AppEngine performs a scan and the object is onscan. Supports conditional trigger types of On True, On False, While True, While False, Periodic, and Data Change. Most run-time functionality is added here. OffScan: Called when the object is taken offscan. Primarily used to clean up the object and account for any needs that should be addressed as a result of the object no longer executing. Shutdown: Called when the object is about to be taken out of memory, usually as a result of the AppEngine stopping. Primarily used to destroy COM objects and.net objects and clean up memory. Scoping Variables Declared variables can be of any data type within the development environment plus object,.net type libraries, and imported types. Declared variables can be up to a three-dimensional array. The issue becomes how to create a.net data type that is persisted from scan to scan and available to other scripts within the object or available to other objects. Since UDAs only support the base data types, a declared variable or script variable must be used. Once the variable has been created and values set, it must be added to the.net global data cache through the following call: DIM Connection AS System.Data.OLEDB.OLEDBConnection; {Set required values} System.AppDomain.CurrentDomain.SetData("MyConnection", Connection); When this variable is required in another script, the variable must be dimensioned within the script and then read from the.net global data cache through the following: DIM DBConnect AS System.Data.OLEDB.OLEDBConnection; DBConnect = System.AppDomain.CurrentDomain.GetData("MyConnection"); Script variables have the same options as declared variables. Note User-defined attributes can only have data types that are available within the development environment and only support one-dimensional arrays.

124 124 Chapter 5 Variables within a Galaxy can have different scopes: Global: Global variables can be accessed from anywhere within the Galaxy. Object attributes and user-defined attributes (UDAs) are used to create global variables. The value is held constant when the object is taken offscan. Script: Variables that have been dimensioned in the declarations section of the script can be accessed from any execution type of the script. These variables will persist from scan to scan, but are cleared when the object goes offscan. Script Execution Type: Variables that are dimensioned within the execution type of the script are only accessible from within that execution type. These variables will not persist from scan to scan. Do not use a UDA if a DIM (dimensioned variable) will suffice. Most UDAs are checkpointed; DIMs are not. Checkpoints consume scan time. The exception to this rule is a UDA set as "calculated", which by default is not checkpointed. Calculated UDAs have the least "weight". Note For more information on DIM Statements, see "Using DIM Statements" on page 146.

125 Working with Templates 125 Scripting for OLE and/or COM Objects The following script change must be made from InTouch QuickScript to Industrial Application Server QuickScript.NET when using OLE and/or COM objects. Within InTouch, the function call OLE_CreateObject(%Name, "ProgramID") is used to create an instance of an OLE automation object with a starting character for the name of either % or #. Within Industrial Application Server, a standard variable name without the leading % or # is used with a "DIM Name as Object" statement. The variable is then assigned to the OLE/COM object by using the CreateObject("ProgramID") function. For example, the following code creates a QI Analyst data component object. InTouch Using Aliases OLE_CreateObject(%QIDC, "QI.DataComponent"); Industrial Application Server DIM QIDC AS Object; QIDC = CreateObject("QI.DataComponent"); Aliases provide a single place for changing the variable, instead of multiple places in the script. This practice makes script maintenance easier when references contained in that script must be changed. Create an Alias: When an external attribute must be referenced in the script. The attribute name is not known or will be unique for each instance of the template. Use three dashes (---) to represent an unknown reference. The dash characters prevent the "could not resolve reference" warning when instances are created. Alias naming can also make the script easier to read and create. When the same relative reference is used multiple times, create an alias for it.

126 126 Chapter 5 Determining Object and Script Execution Order Industrial Application Server enables control of the object scan order within an Engine, and control of the script execution order within an object. Use this functionality instead of "data handshake bits" to ensure the delivery order of data from script to script and from object to object. Before considering script execution order, it is necessary to review how objects execute. The following information reviews object execution events at a basic level. Note For details on object execution, see the object's help files. AppEngine Execution The AppEngine is the only engine that hosts more than one object. Object execution is handled by the scheduler primitive, which is single-threaded. It executes objects registered on the host engine repeatedly, and in a sequential order, during the scan interval. The scan interval is the desired rate of execution of each Automation Object the AppEngine hosts. The following tasks execute engine-to-engine in the following order during the scan interval: Execution Phase: Individual OnScan objects execute their functionality according to there configuration (defined at Config Time). Output Processing Phase: All pending output requests (SetAttributes, subscription packets, publish notifications) must be sent. Pending requests intended for the same engine should be sent as one block request so that the receiving engine can process them atomically (and in order). Checkpoint Snapshot Phase: This task is configured separately and may not occur during every scan interval. If a checkpoint occurs within a given scan interval, it occurs immediately after the Output Processing Phase. The checkpointer status is checked to see if it is still busy from a previous checkpoint. If not, a new asynchrounous checkpoint is initiated with a checkpoint snapshot. Input Processing Phase: The goal of this phase is to process all input requests (SetAttributes, subscription packets, publish notifications). Input requests are retrieved one at a time. If any input requests are left in the queue, they are processed during the idle period before the next scan interval. At least one queued input request is processed following the Output Processing Phase, and before the Execution Phase. Scan Overruns are a boolean condition that becomes true when the Execution Phase crosses from one scan interval to the next. When a Scan Overrun occurs, a new Execution Phase is delayed until the next scan interval begins. Any of the phases in the above list can cause a Scan Overrun when they extend beyond the scan interval. All objects deployed on the AppEngine are processed in the following order: DIObjects (multiple DIObjects are processed alphabetically by tagname), hosted ApplicationObjects, then their Areas (numerically).

127 Working with Templates 127 Common Object Execution Order The execution order of object instances running on an engine is configured within the Object Information tab of the object editor. As an engine executes its scan, it will process the objects in the order specified. Each named script within an object can be specified to run as either just after inputs or just before outputs. The order in which the scripts are listed in either category is the order in which the scripts will be executed. Each object executes its functionality in the following order: 1. Read inputs. 2. Execute "just after inputs" scripts. 3. Execute object native functionality (the UserDefined object has none). 4. Execute "just before outputs" scripts. 5. Write outputs. 6. Test alarms. Each script is executed in its entirety before the next script is executed. This behavior is different from InTouch, where a script can trigger another script, such as a data change script. Within InTouch, the calling script halts while the data change script is run. Within Industrial Application Server, each script completes before the next script is run. If a user-defined attribute of a second object instance is set during the execution of the script, and that UDA triggers a script on the second object, the script of the second object may or may not run during the same scan of the engine. If the second object is configured to run after the first object, the script on the second object will run during the same scan. If the second object has already been serviced during the scan, the script on the second object will run during the following scan. Since the Engine manages each object, a script runs only as fast as the engine's scan period or some multiple of that period. If the engine's scan period is one second, and an object script is set to periodic for every 1.5 seconds, the script will run every other scan (that is, every two seconds). Data requested or sent to objects residing on another engine/platform are updated on the next scan. This is also true for Application Objects on the same AppEngine if an Application Object needs data from another object but it executes before it on the scan. For example, when Object A executes, it needs the output values from Object B. The values received are from the previous scan, because Object B has not executed yet in the current scan. You must wait one scan if you want to verify a write of this type. Alternatively, you can change the execution order in the Object Editor so that Object B executes first.

128 128 Chapter 5 Asynchronous Scripts An asynchronous script runs in a separate thread and is not directly tied into the engine's scan process. Therefore, reading and writing to any object attributes (including the calling object) is a slow process. An asynchronous script should not Read or Write within a long FOR-NEXT loop to a UDA or other external source. Since the asynchronous script runs in a separate thread, it must wait until the next scan of the engine for all the Read or Write transactions to occur. If the scripts have not all been completed at the next scan, the system must wait for another scan. A single-system test with an engine scan period of one second achieved approximately 70 UDA writes per second and 35 UDA reads per second. Asynchronous Timeout Limit Settings The asynchronous timeout limit must also be set appropriately. If the script times out, the script is halted in an indeterminate state. There is no mechanism for determining what line the script was executing when it was halted. Therefore, another script should be checking for asynchronous script time outs and cleaning up any remaining inconsistencies. Scripting I/O References An Onscan script can automatically assign all the input source and output destination attributes of the template to their target reference string. Several different strategies to accomplish this are possible. In general, the suggestions included in this document will only work if a strict naming convention is used throughout the system. Scripting I/O References Example 1 Create an Initialization script that runs when the object first goes Onscan. This script directs all the I/O sources or destinations used by the object to the appropriate device integration (DIObject) object, topic, and address. If at all possible, do not hard-code any of the address components (DIObject name, topic, and I/O address). The one exception might be the I/O address if it is identical in all PLCs addressed by the object. The DIObject should be named in a manner that can be determined from some other component in the system, such as the engine or platform name plus "PLC." The topic should also be determined from some other component in the system, such as Area. If there is only one topic, use a fixed name. For PLCs that allow textual address names such as Control Logix, using the same object or hierarchical name for the instance within AutomationObject Server is the best approach. The following example assumes that one DIObject with one topic called "Topic" is available on the same engine as the object referencing it. The object is based on the $DiscreteDevice template and has two inputs called OLS and CLS representing the open and close limit switches of a valve. The object name partially defines the address name within the PLC.

129 Working with Templates 129 The onscan script is similar to the following example: Me.OLS.InputSource = MyEngine.Tagname + "PLC.Topic." + Me.Tagname + "OLS"; Me.CLS.InputSource = MyEngine.Tagname + "PLC.Topic." + Me.Tagname + "CLS"; Scripting I/O References Example 2 If the PLC does not have textual names, or different brands of PLCs are in use within the facility, the previous strategy can be abstracted one more level by using the attribute list within the DIObject. The Topic tab contains a list of attributes for each tag with a textual name and an item reference. The same code as shown above could be used for a PLC with an address convention of B3:12. In the Topic tab of the device integration object, add a couple of entries for the object. Suppose the object instance name was Valve220; the following entries would have to be in the attribute list: Valve220OLS B3:12 Valve220CLS B3:13 The Onscan script would still be the same. The added advantage of using the attribute list is that all the I/O definitions are located in one central spot. A second DIObject with essentially the same set of I/O points can easily be created and, if necessary, modified by dumping and loading the existing DIObject. Other slight modifications are to store the DIObject name and topic name within UDAs on the area object hosting the automation object. Then it could be referenced by MyArea.DIName, where DIName is the name of the string UDA on the area object. Writing to a Database To write to a database 1. Create an AppDomain object that handles a message queue. 2. At the object level, fill the message queue with the values to be written. 3. At the engine level, create an object that moves the entries from MSMQ to the database, using Stored Procedures. The scripting may run asynchronously as no collecting is required. Note The Message Queue service may use a large amount of memory, depending on the amount of data written.

130 130 Chapter 5 Best Practice The following are best practices to keep in mind regarding scripting: Use stored procedures (SP) when reading/writing to the database to decrease database access time (use a set-up object to create the SPs and then undeploy this object). As an extension to this concept; try to create "services" at a higher level (area, engine or platform) to support common data tasks. Do not use OnScan scripts to access external data from multiple instances simultaneously. Managing object references by accessing external files from all instances at the same time (onscan) is not recommended. Either some type of handshake mechanism between the Platform and object is required to make this a viable approach, or you might use other methods to achieve this functionality. Avoid extensive use of scripting within objects when possible. The extensive use of scripting influences the overall performance of the application. Look for opportunities to reduce the amount of scripting, if possible. Bear in mind that each condition needs to be evaluated, even though the script might not be executed. If you have thousands of these scripts implemented, the scripts will use more CPU time than just the execution of the logic. Instead, use a common database access object on a separate engine to perform a connection/read and then expose the returned data in a UDA array or queue for the other objects to read. This practice allows the database object to stop the scan of its engine without affecting the engine used by the requesting objects. If very robust scripts are needed, asynchronous scripts perform more efficiently because they do not stop executing; however, be aware of the time needed to transfer the data back into the database. Avoid reading a database from within an object script because the engine stops scanning until the connection is made or the query is returned. Using asynchronous scripts does not help in this instance, because the asynchronous script must collect the data and transfer it back into the object for use. If it cannot finish all the 'writes,' it will start over on the next scan. This retrieval can take many scans. Handle database connections using the.net AppDomain object at the AppEngine level. This connection can be used by the Application Objects running on that AppEngine to execute the actual database transactions through stored procedures. An effective implementation is to create a template for DB-connector AppEngines. If every AppEngine () uses the same name for the.net AppDomain object, Application Objects can be configured regardless of the AppEngine on which they run. Do NOT create a database connection for every object.

131 Working with Templates 131 Use asynchronous scripting, when appropriate. For example, use asynchronous scripts to execute functions that tend to "hang" or slow down the processing of other scripts (scripts that verify SQL connections, etc.). Optimize dynamic referencing within scripts. In certain cases it may be necessary to dynamically configure Input source and Output destination references by writing scripts that execute at run-time. It is important to write these scripts so that they execute only one time: When the object is initially deployed. One method of optimizing reference setting is to check within the script to see if the default " --- " is present. If so, the script sets the dynamic reference string. Once the string is set one time, it is checkpointed to disk, so that subsequent Engine or failover restarts will already be configured. This practice is especially important in large systems (large I/O) where reconfiguring thousands of I/O references on Startup (and using excessive CPU resources) is avoided. Use caution when including Data Change scripts. Recall that Data Change scripts are executed in three instances: Value Change, Quality Change, and a Set OnScan event (when the value is set from "nothing" to its default, and the quality changes). When large numbers of Data Change scripts are included, a failover event could cause all the Data Change scripts to execute at the same time, causing unwanted consequences.

132 132 Chapter 5

133 Implementing QuickScript.NET 133 CHAPTER 6 Implementing QuickScript.NET QuickScript.NET is the IAS scripting language and is integrated tightly with.net. The greatest scripting capabilities are leveraged by the application of.net Classes. These are made available through the Function Browser in the Types section. Incorporating imported.net Function DLLs into the Types achieves the best method for customizing the functionality within QuickScript.NET. Desired behaviors can be compiled using source code in any of the.net languages. Existing COM DLLs can be wrapped as.net Function DLLs and incorporated into QuickScript.NET. Import the desired.net function DLL into the Galaxy. The Classes and their methods are exposed for use in the Types section of the Function Browser. The Function Browser is a very useful tool for selecting script functions. This chapter provides practical examples of.net script use within the IAS/ArchestrA environment. Note This chapter assumes basic familiarity with.net concepts and structures. Graphics and script samples are provided from within the IDE Environment. Developing in Visual Studio is outside the scope of this material. Contents IAS Scripting Architecture Script Access to IAS Object Attributes Evolving from InTouch to ArchestrA Accessing the.net Framework Using.NET for Database Access Scripting Database Access Template Object Examples

134 134 Chapter 6 IAS Scripting Architecture Scripting relationships in the Industrial Application Server environment are best considered as a series of "tiers" or layers: QuickScript.NET (Static): Supported by calls to a base.net object and its capabilities. When scripting, a "Dimension" statement is not necessary: the object is accessible via direct or relative reference. This layer contains "out-of-the-box" functionality; arguments of the function calls must support only MX Data types. Also includes basic error handling capability in the form of return value parameters. Basic.NET Types: Supported by all platforms that support.net. The Type functions are accessed through the IAS Script Function Browser: The Types list exposes.net Framework functions, QuickScript.NET functions, and Imported Functions: Microsoft.Example.Name: Supplied with all.net Framework operating systems. System.Example.Name: QuickScript.NET Functions (following figure). Imported Functions: Function Libraries supplied by a developer that include a global namespace identifier (in the above figure, A5.LakeForest.ObjectCacheExt).

135 Implementing QuickScript.NET 135.NET Classes: Provides.NET object capabilities defined in specific function.dlls., specific calls to.net classes/functionality, and Try-Catch- Finally error handling. The following figure shows the System.Array.Copy function: Note Highlighting a function displays the argument list at the bottom of the window.

136 136 Chapter 6 ApplicationObject Script Interactions The following figure shows the script interactions possible within the Industrial Application Server environment. The IAS interactions are grouped to the left; the.net interactions are grouped to the right: aaengine Input (MX) Application Object Domain.NET ObjectCache Subscriptions (InputSource).NET Object Subscriptions (OutputDest).NET Framework ADO.NET Database Legend IAS Scripting Interactions: Modular Script Execution and UDA references Input/Output (Subscriptions) Output (MX) XML Documents.NET Interactions: Referenced Objects (in.net ObjectCache).NET Framework Application Object Domain Note "Application Object Domain" is a.net concept/implementation and should not be confused with ArchestrA ApplicationObjects. An Application Object Domain (often referred to as "AppDomain") is a virtual process that serves to isolate an application. All objects created within the same application scope (in other words, anywhere along the sequence of object activations beginning with the application entry point) are created within the same application domain. Multiple application domains can exist in a single operating system process. In the context of IAS, the Application Object Domain enables multiple scripting access to a common.net object such as the ObjectCacheExt object described later in this chapter.

137 Implementing QuickScript.NET 137 Script Access to IAS Object Attributes The following section summarizes "out-of-the-box" functionality that leverages.net capabilities. Referencing Object Attribute and Property Values Several methods are available within IAS Object QuickScripts to reference Attribute and Property values from other IAS Objects. Attribute and Property values of the current IAS Object may also be read from, and written to, through the use of the self-referencing "Me." keyword prefix. Input/Output The principal method referencing Attribute and Property values of other IAS Objects is through the use of I/O Attributes. The IAS AnalogDevice Object includes the PV Attribute and properties identifying the PV.Input.InputSource. The IAS DiscreteDevice Object supports configuration of one or more discrete Input and/or Output Attributes which receive designations as "Input1," "Input2," "Output1," "Output2"; these support I/O referencing using the Input1.InputSource and Output1.OutputDest Properties. An Attribute may be configured having any of the MxValue datatypes and it can be extended as an Input, as an Output, or as an InputOutput. This is accomplished using UDAs and Extensions. For example, a UDA named Pressure can be added to a UserDefined Object. The Pressure Attribute can be extended assigning Pressure.InputSource. Assignments of the I/O Source can be deferred until run-time by leaving the triple-dash string " --- " in the configuration text field. A run-time QuickScript, typically named IOInitialize and typically configured as Execute WhileTrue - is implemented so that the QuickScript runs once at the first Execution scan. The typical QuickScript I/O assignment command is similar to the following: Me.Pressure.InputSource = MyContainer.DIDeviceName + "." + MyContainer.PLCScanGroup + ".F30[146]"; This example binds at run-time to a DIDevice Object name encoded in a Container Object, to a ScanGroup also encoded in that Container Object and to a hard-coded PLC I/O register. See "Scripting I/O References" on page 128 for more information. It is common practice to embed self-references to Attributes of the current IAS Object within QuickScript code using "Me.", for example: Me.PressureSample = Me.Pressure;

138 138 Chapter 6 Remote references to Attributes of other IAS Objects or to DIDevice Objects may also be encoded directly in QuickScript; however this practice should only be implemented at the lowest level of Object derivation or in Object Instances. WARNING! Direct Remote References embedded in QuickScripts of toplevel templates may be Locked and thus will bind all Instance Objects to that exact hard-coded Remote Reference, disallowing any Instance or Run-time change or Reference..NET Framework The.NET Framework within QuickScript ensures the code syntax remains straightforward, since QuickScript enables many different approaches to the acquisition and processing of I/O data. For example, QuickScripts are used to detect conditions, apply transformation algorithms, post results as I/O as database inserts/updates. Or the QuickScript may simply capture calculated values in UDAs for viewing by InTouch Software or Historization by IndustrialSQL Server Historian. Industrial Application Server includes a number of pre-built.net functions for Math and for String manipulation. These are exposed under specifically named tree branches in the Script Function Browser. Other Script Function Categories Other categories of functions are exposed in the Script Function Browser. The System group within the Script Function Browser tree holds two functions: CreateObject and Now. The CreateObject function is used to instantiate.net Object Classes. Equivalent code may be implemented by first dimensioning a.net Object of the desired type in Declarations and then invoking the new key word in an assignment statement (See examples in Appendix B). The Now function retrieves the computer's system clock timestamp and passes it back as an MX-compatible Time data type. The Miscellaneous group recreates some of the Operating System calls that are popular in InTouch Script: ActivateApp, SendKeys and WWControl. It also includes the ever-popular LogMessage function needed for writing diagnostic messages into the ArchestrA Logger. Additional functions of this group are explained in the following sections IsBad, IsGood, IsInitializing, IsUncertain, IsUsable, SetBad, SetInitializing, SetUncertain. Handling Data Quality Good scripting practice requires that scripts are aware of the notion of Data Quality. Data Quality provides an indication of the "goodness" of any attribute in ArchestrA, and can be one of four main states: Good, Bad, Uncertain or Initializing.

139 Implementing QuickScript.NET 139 A knowledge of Quality handling rules is necessary. In some cases, the quality will be handled automatically (see DQP below), but in others the script writer must explicitly check data quality. For example, if the script writer wants to check if a numerical attribute is exceeding some limit, the script should be written to check the quality of the attribute before performing the limit check. Data Quality Propagation (DQP) ArchestrA scripting incorporates a Data Quality Propagation (DQP) approach to handling data quality. DQP propagates the quality of attributes read by the script through the script s data as execution occurs. DQP allows for the execution of the script even though some of the referenced attributes might have unacceptable quality. Note The script developer must evaluate the quality of the attributes and allow the script to branch into a safe handling condition. Every attribute has an associated quality property. The quality property can be one of the following 4 primary states: Bad, Good, Initializing, Uncertain. In general, attributes with Bad and Initializing qualities are not in a state to be used in a script (other than setting some condition that something is wrong). Initializing quality is a transition state, usually seen when connections are being established or systems are starting up. Attributes with Good quality are normal and can be used. Attributes with Uncertain quality should be used with caution (they may indicate a manual override of a value, for example).

140 140 Chapter 6 Successful script development requires an understanding of the following rules: Only referenced attributes have quality value. Local variables do not carry a quality value when the data value is assigned: For example: Z = MyObject.PV Z has the value of the object but the quality value of the object attribute is lost. However, it is valid to carry the object quality value by direct assignment to a local integer variable: Q = MyObject.PV.Quality If the referenced attribute quality value is Bad, the data value is set to the default value associated with the data type of the respective attribute: type float, bad quality, data value is set to the default NaN (Not a Number). The script system is capable of dealing with the NaN data value in such expressions as: Me.PressureSetPoint = Me.Pressure ; {assigned NaN} {NaN} {Constant} Me.PressureMetric = Me.Pressure * Me.KPAperPSI; {assigned NaN} {NaN} {Calculated Constant} Script functions do not carry quality information. A function such as Float.Sqrt (float attribute value) has the quality information removed. If the attribute quality value is Bad, the data value is set to the default for the associated attribute data type. It is best practice to check the data quality explicitly using one of the convenience functions (i.e. IsGood()) before calling a function to which attribute values are passed as input parameters. Note The function is executed regardless of the quality of the input variable(s). Be sure that the function is called with valid input values. Local variables and constants on the right-side of an expression result in a good quality code being assigned to the left-side attribute. For example: the expression Me.PressureHigh = highpressurelimit; Me.PressureHighHigh = highpressurelimit * highlimitfactor; Me.PressureMinimum = 15.0; {Good} results in the quality value of the attribute being set to good regardless of the quality value of the attribute prior to the assignment.

141 Implementing QuickScript.NET 141 Condition statements are the only instance where the Data Quality Propagation approach takes quality explicitly into account. In all other cases, script execution ignores the quality and the script developer must test the quality explicitly. A standard coding pattern should be followed to allow quality to be taken into account without the explicit testing of the quality, for example: IF ((MyContainer.ValveA == "CLOSED") AND (MyContainer.ValveB == "OPENED") THEN Me.Valve.Cmd = "CLOSE"; ELSE Me.Valve.Cmd = "OPEN"; If the quality of MyContainer.ValveA and MyContainer.ValveB is acceptable then the "IF" and "ELSE" are executed based on the value of the two attributes. However, if at least one of the values has an unacceptable quality (initializing or bad) then the "ELSE" branch is executed. This pattern assumes that the "ELSE" branch is always the fail safe mode. Data Quality Controlled Execution In contrast to constants, local variables and script functions, script expressions adhere to the Data Quality Controlled Execution (DQCE) approach which allows execution of an expression only when the attributes referenced in the expression have acceptable quality. Script expressions are evaluated as a whole or not at all. If any of the input variables to the expression change to an initializing or bad quality state, the result value reported will have a quality of Bad. If a situation exists such that one value is Initializing and another is Bad, Bad quality takes precedence and the expression's result quality value is reported as Bad. The result value itself is set to the default value for the given data type (for example, a result value for a type FLOAT is set to NaN - not a number) when the quality goes unacceptable. If one value is Uncertain and all others are Good, the resulting value is calculated but the resulting quality is set to Uncertain. See Chapter 12, "Maintaining the System," for information about testing the quality of an attribute.

142 142 Chapter 6 Using UDAs UDAs provide read-write interactions between domain objects and facilitate MX subscriptions between object instances. This is handled at the Input/Output level. Use remote references to attributes of other objects which are NOT bound directly to UDAs via InputSource or OutputDest properties. The reference in a QuickScript looks like the following: TankLevel101.PV Or using hierarchical reference: Unit101.Tank.Level.PV Such remote references get subscriptions at run-time but their values are held in a 'memory cache' associated with the Object that contains all such remote references. Even the InputSource and OutputDest extended Attributes have entries listed in the actual memory cache. Inter- and Intra-Object Scripting Considerations Objects can access attribute data within the same object. Objects can also access data in other objects, wherever those objects may exist in the Galaxy. Those interactions are handled by MX. The script simply has to use references, and MX will route the data access to the appropriate location. Evolving from InTouch to ArchestrA InTouch Software and the ArchestrA scripting environments require vastly different implementation strategies. The following information provides some comparison and contrast between the two environments. Inter-Object Scripting Interactions InTouch Software scripting interacts internally using local Memory tags. InTouch Software scripting interacts externally using remote references and Input/Output tags. ArchestrA scripting interacts at the local level using local variables while external interactions are realized by exchanging values via MX. Intra-Object Scripting Interactions InTouch Software scripts interact with a global InTouch Software database. Within the ArchestrA environment, scripts are not exposed to each other except locally (within the object). When using IAS QuickScripts, communicating with other ApplicationObjects is accomplished by using the concept of a reference. The reference can be to any attribute, including UDAs and custom attributes.

143 Implementing QuickScript.NET 143.NET script functions reference objects in a common Application Domain. The.NET ObjectCacheExt runs on the same Application Engine as the objects in the same thread. Remote References to Live Data InTouch Software requires an Access Name for each external Datasource, and supports only DDE, NetDDE, and SuiteLink protocols. The local computer must have a definition of the item. The Galaxy Access Name links using MX. IAS provides remote references to any data from within the Galaxy (within a Global Galaxy Namespace). Indirect Referencing IAS Context IAS version 2.0 introduced the "Indirect" variable type for use within QuickScript. In IAS the behavior of an Indirect variable type is different from the same variable type used in InTouch Software. InTouch Software designates three types of Indirect and the designated InTouch Indirect variable is global to the InTouch VIEW application. For IAS the Indirect is generic for all MX datatypes. A dimensioned Indirect variable is local to the QuickScript that contains it. The BindTo Property is used to redirect the data source or data destination of the local Indirect variable immediately during the same scan. However, there is a limitation that data can only be immediately read during the same scan if the reference points to "Me" or to an Attribute of an Object that is running on the same Engine as the current Object, for example by UDA extension. Indirect Referencing requires the creation of Indirect Tagnames in the InTouch Tag Dictionary that are global within that InTouch Software Application. IAS Indirect Referencing provides dynamic reassignment of InputSource/OutputDest attributes to an object with an existing subscription. When a new reference is created (i.e., a reference to a different object), the reassignment takes effect at the next scan. Note The following material applies to.net functions, not to native QuickScripts. The QuickScript.NET language is not intended to fully replace a developer tool such as Visual Studio. Complex scripting with.net object error trapping and user-generated data types still requires a developer tool to write the code and contain it within a.net or COM component file, such as a.dll,.tlb, or.olb file. These components can then be imported into the Galaxy Repository and be made available within the scripting environment. Any object instance that makes use of an imported library will be deployed with the library file to ensure correct object execution.

144 144 Chapter 6 The main.net editing tool in the IDE is the Script Function Browser (see previous figure). This utility provides access to.net functions registered on the local node. All platforms that support.net expose these function types. Deployed objects automatically install the QuickScript.NET.dll function library (required by the Application Object) on the remote platform. Many types are already installed on the computer. Others are installed by Visual Studio or by installer programs. Note For a list of included.net functions and Sample Scripts, please refer to the IDE Online Help. Accessing the.net Framework.NET Overview The following section provides a high-level overview of the.net scripting environment. Microsoft.NET is based on open standards. It augments the presentation capabilities of HTML with the metadata capabilities of XML to provide a programmable, message-based infrastructure. Like HTML, XML is a widely supported industry standard, defined by the World Wide Web Consortium. XML provides a means of separating data from views, which offers a means to unlock information so that it can be organized, programmed, edited, and distributed in ways that are useful to digital devices and applications. XML and message-based technologies do not replace existing interface-based technologies like COM, whose tightly coupled, synchronous nature is required in many situations, particularly equipment control. However, the tight coupling afforded by interface-based technologies also makes them difficult to implement over the Internet it is often difficult to even establish connections due to firewall constraints. In contrast, an XML instance document, wrapped in SOAP (Simple Object Access Protocol) and bound to HTTP, can pass easily through an enterprise's firewall on port 80, which is typically open for Web traffic. Much like HTML, XML is independent of operating systems and middleware as long as an application can parse XML, it can exchange information with other applications. As such, XML provides developers with a powerful new tool for integrating systems in a highly distributed environment..net Provides an open standards-based framework that enables the following functionality: Within the Application Domain: Use an ObjectCache that is referenced by multiple other objects. The objects use its functionality for common tasks. A common example is to enable multiple objects to access multiple database connections via the ObjectCache. ObjectCacheExt is used for the examples provided in this chapter. Outside the Application Domain: Interact directly with databases (using ADO.NET functions) and.xml instances (using XML.NET functions).

145 Implementing QuickScript.NET 145 Advanced Error Handling: Try-Catch-Finally functionality must be implemented inside of any imported QuickScript Function DLLs with error results exposed as return results through Integer error condition codes or String error messages. Web Services:.NET for Manufacturing introduces the concept of Web services. The Web services model is an Internet-based approach, leveraging the broadest reach and the least expensive communication infrastructure in the world. It uses standard Internet protocols, starting with TCP and UDP to establish connections, HTTP and other protocols to transport data, and XML to describe data..net encapsulates functionality used to interact with database,.xml documents, and Web Services. System.Data Classes (Connection to MSSQL via ADO.NET) It is not possible to pass dimensioned.net objects as parameters of some.net function calls. The work-around is to use Visual Studio.NET and create wrapper function.dlls as a script function library that only take scalar type arguments of the datatypes directly supported in IAS. This is demonstrated in the examples shown in this chapter. Scripting Practices The following information summarizes scripting practices that facilitate effective implementation and script management. Modularize Scripts Breaking the script into smaller pieces enables greater control, management and reuse of content/functionality. TryConnect: See the "TryConnectNow QuickScript" on page 172. Comments: Includes Connection attempts, Retrys and Error Message handling. PostData: See the "PostDataNow QuickScript" on page 177. While True Using a While True script condition ensures that the system is not burdened by unnecessary script processing because once the Expression goes false the script is skipped.

146 146 Chapter 6 Exporting Objects or Templates that Reference.NET Script Functions When exporting objects or templates, DO NOT assume that all functions used by the object exist in other Galaxies. Ensure the Engineer imports the identical script function libraries into the target Galaxy before importing the templates or objects. Syntax Differences Code from VB.NET is not the same as QuickScript - ensure that syntax differences are known before copy/pasting VisualBasic script into the QuickScript editor. Using DIM Statements A DIM statement does not instantiate the.net object. A new statement must also be included in the script body. This concept is especially important in the case of a Dimensioned Connection State object: for the connection to be successful, the object must first be instantiated. Tip Dimensioning statements for variables are supported within any script body. However, the variables are destroyed and recreated each time the script executes. Create dimensioning statements in the Declarations pane. The variable is created one time at Startup and retained for the life of the object. Handling Exceptions QuickScript does not directly support exception handling. Encapsulate.NET Exception Handling inside of a QuickScript function.dll. Using.NET for Database Access The following section describes object examples that connect to a database (using an ObjectCacheExt.dll) and writes generated values to a specific SQL table. Note The following section includes some of the functionality of the OLEDBDataAccess or SQLDataObject2.1 Objects; however, the concepts demonstrated in this example are useful in a broader context. This example illustrates the following key concepts: Defining Project Scope and Requirements Using "Shape" Object Templates for broad application and reuse. Using ObjectCacheExt objects (Script Function library).

147 Implementing QuickScript.NET 147 Posting the Data. System.Data classes (connection to MSSQL via ADO.NET). Scripting practices for effective implementation and script management. Handling exceptions. Defining Project Scope and Requirements The general approach for exchange of data between IAS Objects and a database was introduced in the last section of the previous chapter ("Writing to a Database" on page 129.) The example project in this chapter implements posting of data to Recipe data tables located in a database on MSSQL Server. The project manages the MSSQL database connections, allowing a single connection to each Recipe data table. Multiple Objects posting data are permitted, with the Object determining which data table it wants to post to. Furthermore, the Object must determine if a connection to that data table is available before it posts the data. For run-time testing, Objects will implement a "ChainReaction" that triggers posting of data in a round-robin fashion. Attributes are included that allow run-time control of the "ChainReaction" as well as manipulation of the data to be posted. See Appendix B for information regarding the Chain Reaction technique. This example is predicated on the following information requirements, which are used to define project scope parameters: Determine the required number of Databases: In this example, multiple objects connect to a single (SQL) Database. Determine the number of Target Tables: The SQL Database contains 2 target tables. Determine the Table structure/schema: The Table structure is described in the following sections. Determine the number of required Database connections: Multiple connections to the Database are supported. Determine the number of "clients" connecting to the database: The "client" is an IAS Runtime object (not an external client application). Determine whether the data is Posted or Retrieved: This example describes Posting data. Note Using Database Triggers and Stored Procedures is outside the scope of this example.

148 148 Chapter 6 Using "Shape" Template Objects This example includes a "shape" template object that includes basic functionality required for any derived object to operate successfully. The shape object provides broad application and reuse capability. The shape object methodology provides two benefits: Calls.NET functions implement in C++, C#, or VB.NET. Mimics the Object-Oriented structure of the.net Framework as an inheritance model. Provides the minimum functionality (in this example, Database connection requirements) used by all objects requiring a database connection..net Inheritance Model The following table illustrates how the "shape" object mimics a.net inheritance model: Automation Object Template "Shape" Template Implementation Object Implementation.NET Implementation Virtual Class Class Implementation Class Instances Minimum Database Connection Requirements Must know the Network Node name or the Server Name. Must know the Security Type: Integrated or SQL-type (sa). If SQL, know the authorized account name and password. Must know the connection-type: SQL or OLEDB. Must know the Database name. When a derived object template is created from the "shape" object, the derived UDAs appear in the IDE as Inherited and are called by other UDAs created at the template level. When the object instance is created, it should require only slight customization to be effective. For example, when posting data, a different UDA is required for each data type. If posting Multiple records, use the UDA Array. Using the ObjectCacheExt (Function Library) The ObjectCacheExt Script Function Library DLL enables multiple objects to connect to a database. The instance Object then manages the object connections: who connects, connection status, how many connections are supported, etc. The three contained Classes are: ObjectCacheExt, SQLConnCache and OLEDBConnCache. Note For an example of a basic ObjectCache object, see the IDE Help files.

149 Implementing QuickScript.NET 149 ObjectCacheExt Classes The sample QuickScript Function DLL is located in a file called ObjectCacheExt.dll, and includes three.net Classes: The first Class is simply the base ObjectCache functionality described in the IAS Help documentation covering scripting. The other two Classes implement a variety of useful methods for managing two database connection types. The two Classes are given the following names:.sqlconncache, and.oledbconncache (properties of a.net Class). These two classes are "type safe". This means that each Class only manages.net database connections of the corresponding type of database protocol: SQL or OLEDB. Connection Types Direct ADO.NET calls (direct from QuickScript) are discouraged for the following reasons: It is difficult to manage connections to multiple objects. It is difficult to recover from Connection Time-outs and other failures. Code can easily be manipulated, resulting in "broken" code. The two database connection types represented in the ObjectCacheExt classes encapsulate methods that achieve the following: Communication between multiple objects and one or more databases supporting the designated protocol. Connection pool management. Error handling with descriptive error messages. Prevents scripting errors by referencing a common.dll library. Posting the Data Examples of QuickScript code are listed in sections of this chapter to illustrate the following Demonstrating various techniques applying.net Framework functions. Calling functions of the (example) QuickScript Function DLL. Note For the complete QuickScript and source code for ObjectCacheExt.dll, see Appendix B. Object Functional Encapsulations The object-oriented nature of IAS begs that run-time tasks such as "data acquisition," "data transformation" and "post to database" be divided up and encapsulated in a variety of IAS Objects. Template Objects for these run-time tasks are generally derived as base data management templates directly derived from the base $UserDefined Object.

150 150 Chapter 6 For the examples described in this chapter there should be one instance Object that manages the database connection pool. The connection pool doesn t reside inside of the IAS Object, however. It must be instantiated as a.net Class Instance. The Instance is attached to the Application Domain of the Engine hosting the Instance Object. Scripting Database Access The following objects and script examples are created from the $UserDefined object template. Note The methods described in this section can also be implemented for OLEDB connections. The following figure shows the Derivation view of the objects provided in this section: Because the list is alphabetized, the Derivation View does not show the objects' relationships. In this example, the SqlConnCacheMgr provides the connection maintenance, and the PostTOaOrb objects provide posting for the data and use the SqlConnCacheMgr object for the DB connection.

151 Implementing QuickScript.NET 151 ObjectCacheExt.DLL Overview This section describes the ObjectCacheExt.dll Classes, focusing on the SqlConnCache class functions. SqlConnCache Function Arguments The following figure shows the function arguments as viewed from the Function Browser: The function browser does not indicate the datatypes of the arguments, nor does it indicate the data type of the return value. Function argument datatypes may be guessed from the placeholder names that are given. The sure way to determine the datatypes is to look them up in the documentation for the function. For Microsoft.NET functions, the information can be found in the MSDN documentation or using the Visual Studio.NET Object Browser. The ObjectCacheExt.dll contains the following classes: ObjectCache(): Designates the constructor for the generic.net cache as copied from the example code found in the original Industrial Application Server IDE Help documentation. SqlConnCache(): Designates the constructor for the TypeSafe cache for.net SqlConnection objects. OleDBConnCache(): designates the constructor for the TypeSafe cache for.net OleDBConnection objects. This class is used in the examples described in this section.

152 152 Chapter 6 SqlConnCache Function Calls The function calls generally return a String indicating the result of calling the function, although some return an Integer. The following functions return MXValue Datatypes. The argument Datatypes are given following this list. Functions Add(sqlConnName, sqlobj) Add(sqlConnName, sqlobj, withexceptions) ContainsKey(sqlConnName) ExecuteNonQuery(sqlConnName, SqlCommandText, enablemonitor) Get(sqlConnName) Get(sqlConnIndex) Description Does not return any value (this function internally calls the second Add( ) method setting its third parameter to true). Returns a String with result or Exception. Returns a Boolean indicating whether name is in cache. Returns a String giving number of Database rows affected or the Exception if an error occurs. Returns the SqlConnection object found in the cache. Returns the SqlConnection object found in the cache. GetConnectionString(sqlConnName) Returns the String giving the connection string. GetConnState(sqlConnName) Returns the String describing the connection state. GetDatabaseName(sqlConnName) Returns the String giving the Database name. GetServerName(sqlConnName) Returns the String giving the Server name. GetExecuteNonQueryDuration Returns a TimeSpan giving duration. (sqlconnname) GetExecuteNonQueryCount Returns an Integer count of queries. (sqlconnname) Initialize( ) Returns a String describing success or failure to initialize. Initialized( ) Returns a String indicating SqlConnCache object state. Remove(sqlConnName) Does not return any value.

153 Implementing QuickScript.NET 153 Arguments sqlconnname sqlobj withexceptions sqlconnindex SqlCommandText enablemonitor Description String giving the name of the SqlConnection for the cache. SqlConnection.NET object reference. Boolean when set to true requests handling of Exceptions. Returns the SqlConnection object found in the cache. String giving syntactically correct SQL Command. Boolean when set to true invokes.net Monitor protection. Purpose of ObjectCacheExt.DLL Although it is possible to encode ADO.NET function calls in QuickScript.NET the lack of support for handling Exceptions inline does not allow the Objects to recover gracefully from errors (interruptions) in run-time without the help of Function DLLs. Possible interruptions when trying to implement database interactions include: Wrong node name or server name in connection string. Invalid login - either by proxied user account or by supplied user name and password. Wrong database name or tablename. Invalid or incomplete query command text. Query takes too long and times out. Network cable gets unplugged. Too many SqlConnections trying to talk to MS SQL Server. The ObjectCacheExt.DLL encapsulates many of the desired function calls for gaining access to any particular database and table. It does not restrict which node or which database or table. The SqlConnCache Class handles only SqlConnection types. The OleDBConnCache handles connections to any database via OleDB. These examples focus on.net SqlConnection techniques leveraging ADO.NET internally (within the DLL). The function calls and their return Datatypes are listed above. They represent a reasonably comprehensive set of functions for managing a cache of SqlConnections stored in memory in the Application Domain owned by the IAS Engine. The Engine contains a "manager" Object which calls these functions.

154 154 Chapter 6 The SqlConnCache Class contains only "static" member variables. This means that only one instance of the Class will be loaded. The Class is loaded into memory in the Application Domain of the Engine when an IAS Object running under that Engine first calls any function of the Class.

155 Implementing QuickScript.NET 155 Template Object Examples Two example IAS template Objects are described, although not in complete detail. The $SqlConnCacheMgr deals with creating and managing.net SqlConnection objects in a pool, also called a cache. $PostToDBaORb deals with acquiring the SqlConnection object from the pool and applying ExecuteNonQuery methods against a Microsoft SQL Server database. For complete details of these template objects refer to Appendix B. Example Object Interactions via UDAs The following section describes the object interactions provided by Base Template Object UDAs. The objects are described in functional order. SqlConnCacheMgr The following figure describes the $SqlConnCacheMgr template Object's UDAs. Most of the UDAs are arrays with indexes 1 and 2. This example accommodates up to two independent SqlConnections. The UDAs of interest at this point in the discussion are: SqlConn.Name[1] holds the String to be given to the cache as the name of the SqlConnection. Connection.AcquiredBy[1] is a placeholder for the name of the IAS Object Instance that "reserves" the named SqlConnection for its own use. SqlConn.Name[1] SqlConn.Name[2] f LogMessages.Enabled f1 f2 k1 k2 l1 l2 m1m2 n1 n2 o1 o2 p1 p2 a b1 b2 c1 c2 d1 d2 e1 e2 SqlConnCacheMgr q1 q2 r1 r2 a SqlConn. GetStatistics.Now b Connection. Acquire[1] Connection. Acquire[2] c d e g1 h1 i j Connection. Release[1] Connection. Release[2] Connection. Connect[1] Connection. Connect[2] Connection. Disconnect[1] Connection. Disconnect[2] g2 h2 SqlConn. Initialized[1] SqlConn. Initialized[2] SqlConn. Result[1] SqlConn. Result[2] h Query. Count Query. Duration Connection. AcquiredBy[1] Connection. AcquiredBy[2] Connection. Status[1] Connection. Status[2] q r g k l n o Connection. Database. Name[1] Connection. Database. Name[2] Connection. NodeName[1] m Connection. NodeName[2] Connection. IntegratedSecurity[1] Connection. IntegratedSecurity[2] Connection. User. Name[1] Connection. User. Name[2] p Connection. NodeName. Validated[1] Connection. NodeName. Validated[2] Connection. User. Password[1] Connection. User. Password[2]

156 156 Chapter 6 PostToDBaORb The $PostToDBaORb template Object is shown in the following figure. Instances derived from the template take care of acquisition of data that will be posted as a new row to a database table. Derived Object instances do not create their own.net SqlConnection. Instead they reserve a connection owned by the $SqlConnCacheMgr Object instance. A $PostToDBaORb Object instance gets a.net SqlConnection Object reference from the SqlConnCache Class, then it invokes several methods of the Class to Open the SqlConnection and post a new row of data. The Object releases the named SqlConnection when it is finished with it. SqlConn.Name SqlConn.Name.Prefix g h g l n p l m n o p q LogMessages.Enabled h m o q DB. Name.A DB. Name.B a a Connection. NodeName.A Connection. NodeName.B Connection. TryConnect Connection. IntegratedSec.A Connection. IntegratedSec.B b c d b c e Connection. Acquired.ByA Connection. Acquired.ByB d Connection. Connect. ToAorB f e DB. PostData f Connection. Disconnect i Connection. Result j Connection. State k Connection. Attempts PostToDBaORb v DB. PostData. Result w1 DB. PostData. ResultEnum[1] ---- w4 DB. PostData. ResultEnum[4] r s1 t1 u1 s10 t10 u10 r DB. TableName s1 DB. Column. Name[1] ---- s10db. Column. Name[10] t1 DB. Column. DataType[1] ---- t10 DB. Column. DataType[10] u1 DB. Column. ValueString[1] ---- u10db. Column. ValueString[10]

157 Implementing QuickScript.NET 157 Application Domain Interactions The following figure illustrates where the SqlConnCache's cache resides and how SqlConnection object references get stored. A hash table sits in memory external to the $SqlConnCacheMgr Object instance. This remains within the memory context of the Engine that runs this Object instance. This memory context is known as the Application Domain and is associated with the specific aaengine process under which the Engine runs. The cache itself is organized as a list of SqlConnection names (String Datatype) designated by the UDA SqlConn.Name[n]. The name in the hash table links to a reference pointer in memory linking to the.net SqlConnection Object. SqlConnCache ConnectionDBa ConnectionDBb k1 k2 l1 l2 m1 m2 SqlConnCacheMgr creates connections q1 Database Name Node Name Security type q2 read/write b c read/write Object chooses connection "a" or "b" l m PostToDBaORb connection used for ExecuteNonQuery table insert n o p q

158 158 Chapter 6 $SqlConnCacheMgr Script Examples $SqlConnCacheMgr is used as a "shape" template object. Note An IAS Instance Object needs to be instantiated that may be deployed to implement the run-time support for SQL Database interactions. The sole purpose of $SqlConnCacheMgr is to initialize and manage one or more.net SqlConnection Objects. Other Object instances are then used to do all of the hard work of manipulating the database table rows. Pooled SQL connections are acquired and applied. They are managed by the instance Object derived from the $SqlConnCacheMgr template Object. Initialize QuickScript The $SqlConnCacheMgr includes many UDAs used to keep track of its own state and the state of a cache of.net SqlConnection objects. (See Appendix B for a complete listing of the UDAs). Several QuickScripts operate within the Object. The Initialize script must execute before any other script, thus its execution order is stipulated to be first. Use Configure Execution Order in the QuickScript editor window to modify the execution order of scripts: The purpose for declaring local variables in the Declarations section (of any Object's QuickScript) is to establish the variables in memory upon Object Startup. Such variables are local to the named QuickScript but their lifetime extends until Shutdown of the Object. Local means that the variable can be read and written to from within any of the script types (Startup, OnScan, Execute, OffScan, and ShutDown) but only within the context of the named QuickScript. Note The following examples are not complete and shown from the script editor as graphic images. For the complete, copy-able source code, see Appendix B,.NET Example Source Code.

159 Implementing QuickScript.NET 159 Dim (Dimension) Code Sample In this example the ConnectTo QuickScript cannot interact with the local variables of the Initialize QuickScript. Declaration of local variables is not restricted to the standard IAS Datatypes. In the Initialize example.net SqlConnection objects are declared: It is good practice to fill in the complete.net Type designation, although the short form SqlConnection will work. A full designation ensures there will be no ambiguity when imported Function DLLs exist that may have the same named function under a different.net namespace. It is also important to understand that the use of the Dim statement does not by itself create the variable in memory. Dim is used to establish a Type Safe Datatype for the named variable. The QuickScript compiler will give warning messages for code that attempts to use the variable if it happened to be a different Datatype than the one declared using Dim. Load the Library into Memory Code Sample The following QuickScript code from the Initialize script invokes the SqlConnCache Class of ObjectCacheExt.DLL. The first line of code looks at the Initialized state. Within the IF ENDIF block the Initialize( ) function is applied. The very first call to any function of the SqlConnCache Class loads the ObjectCacheExt.DLL into memory. Don't be confused by the fact that the Function DLL has a method with the same name as the QuickScript itself: The IF ENDIF block ensures that the Initialize function call will be invoked only when the initial state of the SqlConnCache is double-quotes (""), meaning Blank. Cache Look Up Code Sample The next QuickScript line of code from the example applies the Class's ContainsKey( ) look-up function. It retrieves the Boolean answer to the question: "Is there a.net SqlConnection Object held in the cache by the name contained in Me.SqlConn.Name[1]?"

160 160 Chapter 6 Me.SqlConn.Name[1] is an Attribute of the $SqlConnCacheMgr Object Instance. It indicates the first indexed String in an array of Strings. The instance Object will contain the actual name to be used for identifying the.net SqlConnection Object stored in the cache. Create Connection Code Sample The code within the following IF ENDIF block is only processed if the particular named.net SqlConnection is not yet present in the cache. If not yet present, a connection is created: In order to establish any.net Object in memory the new operator is used in an assignment statement. The following statement binds the new Object to the local variable sqlconnectiondba which had been previously dimensioned in the Declarations section: This particular function call invokes the constructor for a new.net SqlConnection object and leaves it essentially empty as a default, ready to make a connection to an MSSQL database. The local variable (sqlconnectiondba) had been previously declared as a local.net Object variable of the desired type in the Declarations section. Upon assignment as new it goes into memory in the scope of the Initialize QuickScript at Object instance Startup. It then stays in scope until the $SqlConnCacheMgr Object instance goes through Shutdown. Note however that the new reference to a.net SqlConnection is not yet accessible for use by other IAS Objects, nor is it accessible immediately by other QuickScripts of the same $SqlConnCacheMgr Object instance. As described in the previous section, the $SqlConnCacheMgr Object instance must place a reference to the new.net SqlConnection Object into the cache. This is achieved using the following line of code in the example:

161 Implementing QuickScript.NET 161 The Add method places the String name for the.net SqlConnection Object into the hash table in the Application Domain. It uses the value from UDA Me.SqlConn.Name[1] of the $SqlConnCacheMgr Object Instance. That value is inserted into a hash table as a sqlconnection name and a reference to the new.net SqlConnection Object is passed along to the hash table as well. The.NET SqlConnection object reference has been attached to the locally declared variable (sqlconnectiondba). The third argument set to true means that the function call should investigate Exceptions and return a String identifying them if and when they occur. Note that the SqlConnCache Class's Add method inspects the Type of the.net object that is passed in by reference. If the.net object is not of Type System.Data.SqlClient.SqlConnection, it is not added to the cache but an error message String is returned. Thus the Add function is Type Safe. A local variable (resultconnectiondba) captures the return value String which is may be inspected using Object Viewer because it gets copied into a UDA: It is good practice to use locally dimensioned variables to capture return values coming from Function calls. Such local variables may then be inspected using IF THEN ELSE logic to detect error conditions. Finally, an interpreted form of the result or a truncated error message can then be copied into a full UDA of the Object instance. OffScan Transition Code Sample The proper coding for the $SqlConnCacheMgr Initialize QuickScript also considers what must happen when the Object instance goes OffScan. The following code deals with this transition: This code checks the cache again to see whether the.net SqlConnection Object is present. If so it is gracefully removed by applying the Remove function call. The balance of code in the OffScan QuickScript cleans up the state of the cache in memory, providing a guarantee that the cache will be ready for new.net SqlConnection Objects once the $SqlConnCacheMgr Object Instance is brought back OnScan.

162 162 Chapter 6 Boolean UDAs in QuickScript Execute Triggers The $SqlConnCacheMgr Object contains a simple QuickScript called Statistics, which periodically retrieves SqlConnection query count and duration information. The SqlConnCache Class is responsible for calculating the information. However, the statistics would just sit there if the Object instance didn't ask for them. The Expression that triggers the Statistics QuickScript is an illustration of a programming technique that allows for granular control of run-time execution. The following figure shows the Expression with the OR operator: Two UDAs are used to determine when the Statistics QuickScript runs: Me.SqlConn.GetStatistics.Periodic Me.SqlConn.GetStatistics.Now The first of these is set to true by default. The second defaults to false. Either UDA being true results in periodic execution repeated every Trigger period. If the Periodic attribute is set to false, the Statistics QuickScript execution depends entirely upon the Now UDA. Upon setting the Now UDA to true the QuickScript executes once and stops. This is generally called a one shot among control system engineers and technicians. An alternate method utilizes a single Integer UDA as the trigger. The Expressions look to see if the Integer UDA is greater than zero. Non-zero values trigger the QuickScript. Inside the QuickScript would be IF ELSE ENDIF blocks that vary the actions according the actual value of the Integer UDA.

163 Implementing QuickScript.NET 163 ManageConnections QuickScript The ManageConnections QuickScript of the $SqlConnCacheMgr template Object handles requests from other IAS Objects to acquire.net SqlConnection objects from the pool of connections. Following are excerpts from the QuickScript: Template Object QuickScript Name $SqlConnCacheMgr ManageConnections Declarations: OnScan Script (Sample): Execute Expression Me.Connection.Acquire[1] AND Me.SqlConn.Initialized[1] Execute Trigger Type WhileTrue Execute Trigger Period 00:00:

164 164 Chapter 6 Execute Script (Sample): First, in the OnScan script a local variable (afterinitialized1) is set to false. This is used to cause a single pass through the Initialization section at the beginning of the ManageConnections Execute script. Upon completion of one pass through this section this local variable is set to true.

165 Implementing QuickScript.NET 165 Although it is tempting to place such initialization code inside of the OnScan section this would not work because the script trigger, even for Initialization, depends upon a Boolean UDA value collected from another IAS Object instance. The script must wait until that Boolean value transitions to true. The OnScan script runs only once; thus code within this script section will execute long before any other IAS Object needs to invoke the initialization steps. The following script excerpt from the Execute section ensures the execution of a single pass only when the UDA Me.SqlConn.Initialized[1] goes true: Within that initialization code a call to the SqlConnCache Class's ContainsKey function looks to see if the named SqlConnection happens to already be in the cache. The result of the function call is copied into the local Boolean variable (foundconnectiondba): If it does exist in the cache, the Class's Get function is called within the code block: IF foundconnectiondba THEN ENDIF. Note that the local variable (sqlconnectiondba) has been dimensioned in the Declarations section as an ADO.NET connection object, i.e. System.Data.SqlClient.SqlConnection. Once again it is important to understand that the Declarations section does not place such variables into memory, it only defines the Types of variables for compiler checks. Furthermore it is important to understand that the Declarations section in the ManageConnections QuickScript is essentially independent of the Declarations section in the Initialize QuickScript; thus the Dimension statements are repeated. It is perfectly acceptable to use different local variable names in differently named QuickScripts, even for the same Type of variable. Keeping the same local variable names is actually a convenience of "cut and paste" editing. Once the distinction is made that the two QuickScripts (Initialize and ManageConnections) have independent local variable scope, there should be no confusion in reuse of the local variable names. Just remember to provide the appropriate Dim statements in the Declarations sections.

166 166 Chapter 6 Review the line of code that retrieves a.net SqlConnection object from the cache: Remember that the UDA Me.SqlConn.Name[1] contains the String value of a name given to an available cached.net SqlConnection object. It happens to be the first indexed element of an array of Strings. The Get function invokes the SqlConnCache Class method called Get passing along the name to look up in the hash table. If the name happens to be found in the hash table (i.e. it is in the cache), a reference to the associated.net SqlConnection object is returned and attached to the local variable (sqlconnectiondba) which by design has been defined (Dim) to be a System.Data.SqlClient.SqlConnection. Note that this script does not utilize the new keyword. It is not necessary in this case because the.net SqlConnection object already exists in memory and has a reference stored in the cache: What happens if the named.net SqlConnection object is not found in the cache when another IAS object requests it? Even though the Initialize QuickScript was supposed to have created the required.net SqlConnection object, another QuickScript called DisconnectFrom exists. If this QuickScript had been invoked it is possible that the desired named SqlConnection will have been removed from the cache. Under this scenario it is important that the ManageConnections QuickScript be able to recreate the SqlConnection and reinstate it in the cache: Thus the new keyword does get applied in this scenario. The UDA Me.Connection.Status[1] gets a copy of the State of the.net SqlConnection. The ToString( ) function is a universal.net method that translates any object parameter into a readable String. Having just created a new.net SqlConnection object, the State should in fact be Closed. Once created it is added to the hash table (the cache) by applying the Add function and the result is placed into the local variable (resultconnectiondba).

167 Implementing QuickScript.NET 167 Eventually the local variable representing the presence of the SqlConnection (foundconnectiondba) achieves the true Boolean condition. The UDA Me.Connection.Acquire[1] will still be true because another IAS Object is trying to get a valid.net SqlConnection from the pool. The following code is then executed, configuring the SqlConnection parameters. Note that these parameters are for the SqlConnection and do not in this QuickScript deal with executing any queries. That will be the job of the other IAS Object (see the $PostToDBaORb Template Object later in this chapter): Per the logic of acquiring a valid.net SqlConnection from the pool, it is always necessary to insure that a reference is retrieved from the cache, so these lines of code are repeated. The Status is then inspected. If the SqlConnection is Closed, the following code generates a connection string and applies it in an attempt to establish a live connection with Microsoft SQL Server. The node name of the Microsoft SQL Server is supplied in the string. Note that the format of the connection string will vary depending upon whether the UDA is Me.Connection.NodeName[1]. If another UDA, namely Me.Connection.IntegratedSecurity[1] is set to true. If the security UDA is false, user name and password are passed along from UDAs Me.Connection.User.Name[1] and Me.Connection.User.Password[1]. Note that this technique for passing along a password is not entirely secure because the UDA can be read in plain text using Object Viewer. This code sample also illustrates a common technique in QuickScript whereby a String local variable repeatedly gets additional String values appended to it (connectstringa) upon finishing the connect string by appending the database name:

168 168 Chapter 6 However, if the.net SqlConnection object is found not to be Closed, a message is logged giving the actual current status: Finally the trigger Boolean UDA Me.Connection.Acquire[1] is set back to false upon completion of the task of making a live connection to a Microsoft SQL database. ConnectTo QuickScript The ConnectTo QuickScript of the $SqlConnCacheMgr template Object handles requests from other IAS Objects to find existing, or create new.net SqlConnection objects from the connections pool, without acquiring it for its own use. The code is not reproduced here because it is essentially the same as that of the ManageConnections QuickScript. If one script performs essentially the same function as another, why have such a script? The answer lies in the fact that there are many scenarios where other IAS Objects feel the need to initialize a SqlConnection in the cache but they don't need to acquire it immediately for their own use.

169 Implementing QuickScript.NET 169 Certainly a single QuickScript function could handle each scenario internally using IF ELSE ENDIF logic. This would simply require that the trigger expression include several UDAs or a single Integer UDA that encodes the desired choice of action. Alternatively the UDA could be a String that is encoded with a command word such as INITIALIZE or ACQUIRE. It comes down to design choices. For these examples, the engineer chose to use separate UDAs triggering separate QuickScripts. DisconnectFrom QuickScript The DisconnectFrom QuickScript handles requests from other IAS Objects to remove existing.net SqlConnection objects from the connection pool. The Execute trigger expression for this QuickScript includes only the UDA Me.Connection.Disconnect[1]. Most of the lines of code from this QuickScript are not reproduced here. The following lines, however, merit consideration: This code fragment illustrates the technique for cleaning up the hash table (the cache) owned by the SqlConnCache Class. When it is determined that the.net SqlConnection is still Open the.net SqlConnection's Close method is invoked. Note that the local variable (connection1) had been defined as a System.Data.SqlClient.SqlConnection in the QuickScript Declarations section using the Dim statement. Also not shown above is the mandatory Get function call, which binds a.net SqlConnection reference from the cache to the local variable (connection1). The state of the SqlConnection is then copied into the UDA Me.Connection.Status[1] and if the SqlConnection's State property has achieved Closed status, the Remove function is called to expunge the SqlConnection from the cache. Finally as cleanup, the ContainsKey function is called looking for false. This allows the QuickScript to then clear the UDA Me.Connection.AcquiredBy[1] to a null String (""), which signifies that the SqlConnection is not acquired any longer.

170 170 Chapter 6.NET Error Handling and Garbage Collection QuickScript.NET does not support invocation of.net Try Catch Finally syntax in IAS Objects. Error handling is encapsulated in the SqlConnCache Class inside of the ObjectCacheExt.DLL. The complexities of handling exceptions are hidden away from the Industrial Application Server programmer. In fact the following kinds of.net Exception are investigated within the DLL, returning a simple String error when encountered. The bodies of the following "catch" clauses are not shown here: catch (TypeLoadException tldexception) catch (NullReferenceException nrefexception) catch (InvalidOperationException invalidopexception) catch (Exception e) The programmer creating the IAS Object must still create logic that reacts to the error message Strings returned by the function calls. Programming languages prior to Java and.net required careful management of memory by explicitly allocating and de-allocating it..net performs automatic Garbage Collection. This means that objects that are no longer referenced at certain steps are available for elimination, thereby recovering memory. For example, when SqlConnection is eventually removed from the cache, the.net Framework returns that amount of memory to the.net managed heap. This operation is performed automatically. $PostToDBaORb Template Object Previous examples addressed the creation of.net SqlConnection objects in a pool (the cache) and initializing them by "Opening" the database, given a SQL connection string identifying nodename (i.e. server name), security information, and the database name. The IAS $PostToDBarORb template Object provides functionality for posting data into a table of the database by way of the "Opened" connection. (For the full documentation of the example QuickScripts and Object configuration refer to Appendix B). UDAs Following are selected UDAs defined in the $PostToDBaORb template Object. Datatypes and array designations are omitted: Connection.Acquired.ByA Connection.Attempts Connection.Connect.ToA Connection.Connect.ToAorB Connection.Disconnect Connection.IntegratedSec.A Connection.NodeName.A

171 Implementing QuickScript.NET 171 Connection.TryConnect DB.Column.DataType DB.Column.Name DB.Column.ValueString DB.Name.A DB.PostData DB.TableName SqlConn.Name Note that the UDAs are segregated into groups using the convenient dot separator. This technique mimics the hierarchical naming structure of IAS within a single Object. Also note that the prefix for each is a functional name - Connection, DB and SqlConn. This convention provides a strong hint as to the purpose of the UDA. UDAs Extended in $PostToDBaORb In the block diagrams shown on a previous page, commands are linked between an instance of the $PostToDBaORb Object and the single instance of the $SqlConnCacheMgr Object. The method of linking is quite simple. The $PostToDBaORb instance Object contains several UDAs that are extended as InputOutput with a remote reference to the $SqlConnCacheMgr instance Object's corresponding UDA. For example the UDA Connection.Acquired.ByA has its InputOutput linked to SqlConnCacheMgr.Connection.AcquiredBy[1]: Note that the text window cuts off the beginning of the text field in this figure. Also note that the UDA of the $SqlConnCachMgr instance Object is indexed to the first element of an array of type String. This particular UDA array serves as a reservation system. An Object links to this UDA and places a String value giving its own Tagname (using Me.Tagname in scripting) into the UDA, thus acquiring exclusive rights to the.net SqlConnection object owned by the $SqlConnCacheMgr instance Object. When finished with the SqlConnection, the $PostToDBaORb instance Object clears the String value to a null String (assigning double-quotes "") and the reservation is withdrawn.

172 172 Chapter 6 In fact, nothing prevents a greedy $PostToDBaORb instance Object from latching onto the reservation permanently. It can just leave its Tagname in the UDA forever if it so chooses. TryConnectNow QuickScript Previous examples addressed the creation of.net SqlConnection objects in a connection pool using the SqlConnCacheMgr Object. Template Object QuickScript Name $PostToDBaORb TryConnectNow Declarations: OnScan Script (Sample): OffScan Script (Sample): Execute Expression Me.Connection.TryConnect Execute Trigger Type WhileTrue Execute Trigger Period 00:00:

173 Implementing QuickScript.NET 173 Execute Script (Sample):

174 174 Chapter 6 Determining Connection Choice One interesting method for determining a choice of.net SqlConnection is implemented in the $PostToDBaORb Object. The method is illustrated in the combination of the OnScan script and the first few lines of the Execute WhileTrue script: OnScan Script (Sample): Execute While True Script (Sample): Actually the choice for a.net SqlConnection is pre-encoded: A suffix letter taken from the Tagname of the $PostToDBaORb instance Object is used to designate the choice. The OnScan script simply picks off the last letter of Me.Tagname and copies it into a local variable (connectletter).

175 Implementing QuickScript.NET 175 The UDA Me.Connection.Connect.ToAorB also gets a copy of the "letter" so that it may be used in other scripts. This is done in the OnScan script because it doesn't need to be collected repeatedly. Two examples of Object instance names are PostTOa and PostTOb which fill in the UDA with a and b respectively. These designate the first and second indexed SqlConnection objects. The Execute WhileTrue script is invoked by setting a UDA of the $PostToDBaORb instance Object (Me.Connection.TryConnect) to true. The script then tries every 5 seconds to get a.net SqlConnection from the $SqlConnCacheMgr instance Object. The following line of code should be familiar by now: The local Boolean variable (hasconnection) gets set to true only if the desired.net SqlConnection object already resides within the hash table (the cache). The name of the.net SqlConnection object is given by the String value encode in the UDA Me.SqlConn.Name. Once it is determined that the SqlConnection is really in the cache QuickScript code acquires it for use: Recall that the local variable connectacquiredby has gotten a copy of the value from the InputOutput extended UDA Me.Connection.Acquired.ByA or alternately from the.byb UDA. The IF ELSE ENDIF block checks to see whether that UDA value happens to be the very Tagname of the acquiring object. If it matches, the SqlConnection is already correctly reserved by the instance of $PostToBDaORb. If not, an attempt is made to acquire by poking the instance Object's name, i.e. Me.Tagname into the InputOutput extended UDA, which happens to be bound to the reservation UDA Me.Connection.AcquiredBy[1] of the $SqlConnCacheMgr instance Object.

176 176 Chapter 6 For the "b" case the second array element [2] gets the reservation Tagname String value. Then the repeating cycle of the QuickScript execution is halted by setting the trigger false. If a SqlConnection reservation has not been acquired successfully the following IF THEN test increments a local variable to count attempts, comparing it against a configured maximum number of attempts encoded in a UDA. If the engineer should forget to fill in a number during configuration, after 10 attempts the QuickScript clears the trigger UDA: TryConnectOnFalse QuickScript Template Object QuickScript Name $PostToDBaORb TryConnectOnFalse Declarations: OnScan Script (Sample): Execute Expression Execute Trigger Type Execute Runs Asynchronously Me.Connection.TryConnect OnFalse Checked Execute Script (Sample):

177 Implementing QuickScript.NET 177 The very simple QuickScript called TryConnectOnFalse serves a very simple purpose: It cleans up connection states. Note that the local variable connectletter is used again to indicate which of two connections the instance Object is dealing with. Alternatively, a reference to Me.Connection.Connect.ToAorB could have been used for this purpose. PostDataNow QuickScript Template Object QuickScript Name $PostToDBaORb PostDataNow Declarations: Execution Expression Execute Trigger Type Me.DB.PostData OnTrue

178 178 Chapter 6 Execute Script (Sample):

179 Implementing QuickScript.NET 179 This appears to be a complex QuickScript. It is called PostDataNow because that it what the instance Object is supposed to try to do, leveraging the acquired SqlConnection from the cache. The first part of the QuickScript contains the often-used connectletter technique for determining which SqlConnection shall be targeted. Note that the OnScan QuickScript of PostDataNow is omitted being the same as previous QuickScripts. The following excerpt from the above script copies configured UDA values into local variables, concatenates the connectletter to a prefix to identify the desired SqlConnection name from the cache. Then the cache is checked, copying the Boolean result into the local variable hasconnection: If the SqlConnection really is in the cache and it has been acquired by this instance Object the status of the connection is retrieved by a call to the Function DLL and copied into a local variable.

180 180 Chapter 6 If the SqlConnection is Open, a CommandText String is generated. The use of FOR NEXT loops is a convenient method to build the String, adding indexed elements of UDA arrays. The first FOR NEXT loop fills in the list of Column names for an INSERT Query: The second FOR NEXT loop fills in data values of the INSERT query. Note that there are IF ENDIF blocks which test the column DataType and insert single quotes into the query where they are needed to accommodate the particular DataType. DataTypes are encoded in elements of a UDA array:

181 Implementing QuickScript.NET 181 The INSERT query is wrapped up, and the moment of truth arrives where the ExecuteNonQuery method of the SqlConnCache class gets executed. This query could take several seconds. Hence this QuickScript's Execute operation has been marked as Runs asynchronously. The FOR NEXT loop that follows illustrates a technique for taking a result String value, looking it up in a UDA String array (an enumeration) to determine if the result matched a known Exception type. Note the use of the EXIT FOR keywords. They are used to jump out of the loop when a match is found: If there was not an Exception the QuickScript inspects the result for useful information such as the number of rows affected by the INSERT query. This number is extracted and concatenated into a result UDA: Finally the trigger UDA is cleared:

182 182 Chapter 6 The ExecuteNonQuery method is not restricted to INSERT CommandText strings. Any valid query statement that returns a simple result string will suffice. The SqlConnCache Class (as well as the OleDBConnCache Class) was compiled including the ExecuteNonQuery method because is quite basic and doesn't need a lot of other methods to look at the query results. $PostTOaORb Derived From $PostToDBaORb The QuickScripts within the $PostToDBaORb template Object do not deal directly with the acquisition of data needed to populate the INSERT query. The assumption for this template is that the data comes from somewhere and is copied into the array elements of the UDAs. To test the performance of the INSERT query in a live scenario, another template Object - $PostTOaORb - is derived from the original template $PostToDBaORb. The inherited QuickScripts handle acquiring a SqlConnection and posting the data. Specific QuickScripts take care of generating data and pushing the values into the UDA array elements. These QuickScripts are not reproduced here; however some examples of other interesting QuickScript techniques are illustrated. (See Appendix B for the fully documented template). RandomizeNow QuickScript Template Object QuickScript Name $PostTOaORb RandomizeNow Declarations: Execution Expression Execute Trigger Type Me.Product.Randomize OnTrue The.NET System.Random object must be initialize in the standard way for any.net object. The OnScan QuickScript applies the new operator. Each time the trigger UDA goes true a newly randomized value is generated and copied into a UDA.

183 Implementing QuickScript.NET 183 This example creates two values in units of percent (%) from the single System.Random object. Several method calls generate different random result Datatypes depending upon the call. The NextDouble method of the object gives float values between and or whatever precision you're interested in. The QuickScript multiplies by and copies the result to a UDA, then subtracts that result from for the other UDA. Another example of a technique is the use of a lookup table stored in a UDA array: Starting with the randomly generated randompercent local variable, an index integer (enumindex) is extracted using the mathematical function Round. Then an IF ENDIF block ensures that the index doesn't stray out of the range 1 to 5. This number is then used as the index of the UDA array Product.Status.Enum[enumIndex], and that String value is copied to a status String UDA Me.Product.Status. This UDA is one of the String values posted with the data in the INSERT query. Time-Based Calculations and Retentive Values The following section presents the example $RunTime template Object. The Object functions as a multi-function Stopwatch that captures elapsed times for "Running" and "Held," and includes automatic calculations of percent time in either state. Timer QuickScript in $RunTime The $RunTime template Object illustrates time-based calculations leveraging fundamental.net calculations supported directly in QuickScript.NET without the need for a custom Function DLL. $RunTime UDAs illustrate another important concept - retentive data. In support of Engine failover calculations, an Object must be preserved and reinstated upon restarting the Object when a backup Engine picks up as Active. The failover scenario leverages the Checkpoint files that are copied from the Primary to the Backup Platform via the RMC. UDAs of an Object that are marked as Category Calculated retentive are captured periodically and copied over to the Backup within the Checkpoint files.

184 184 Chapter 6 MX DataTypes are not comprehensive with respect to what may be needed to perform all of the necessary calculations within an Object. This example illustrates the use base System.Int64 as a high precision DataType. It happens that the MX Datatypes Time and ElapsedTime are directly compatible in precision with.net System.Int64 - i.e. they all carry 64 bits of data. In order to properly perform calculations that are time based it is imperative to do them using this high precision base.net type. Template Object: $Runtime UDAs (partial list) UDA Name Data type Category Clock.EndTime Time Calculated retentive Clock.StartTime Time Calculated retentive Clock.ElapsedTime ElapsedTime Calculated retentive Running.ElapsedTime ElapsedTime Calculated retentive Running.PercentOfClock Float Object writeable QuickScript Name: Timer Declarations

185 Implementing QuickScript.NET 185 Startup Script:

186 186 Chapter 6 OnScan Script:

187 Implementing QuickScript.NET 187 Name Trigger type Trigger Period Execute script Periodic 00:00:

188 188 Chapter 6 The Startup script for "Timer" includes all of the code that initializes the dimensioned.net variables e.g.: and calcperiodt = new System.TimeSpan; lastscan = new System.DateTime; An IF THEN block checks whether the Engine is not in the recovery state, for example following a failover. IF NOT MyEngine.Engine.StartingFromCheckPoint THEN. For the case that there has not been a failover, it is assumed that the Object instance is starting up for the first time. Therefore the variables need to be properly initialized, i.e. not reinstated from Checkpoint data. Several of the UDAs of type Time are initialized by applying the QuickScript.NET function call Now( ), which grabs the time stamp from the computer's system clock. Me.Clock.StartTime = Now(); Also note that dimensioned local variables (defined in the Declarations section) are used to make time calculations and they are initialized in the Startup script. cstrtt = Me.Clock.StartTime; A pair of statements appear to copy the same initialization data into two different local variables: calcperiodt = Me.CalcPeriod; calcperiodl = calcperiodt; Actually the two local variables are of two different.net data types: The first is System.TimeSpan and the second is System.Int64. Calculations comparing time inside of IAS QuickScript.NET must be performed using 64 bit arithmetic. So when differences in time must be evaluated, the System.Int64 local variables must be used. The example script code lines first capture the "retentive" Me.CalcPeriod of MX ElapsedTime, and converts it into a System.TimeSpan. The System.TimeSpan is implicitly converted into a System.Int64 for use in calculations. As stated above for Startup, in the event that there has actually been a failover the Startup script will run, but the local variables will not be initialized, having verified StartingFromCheckpoint and thus skipping that section of code. Instead the OnScan script recovers the correct values from the Checkpoint files, for example: cstrtt = Me.Clock.StartTime; The real work of the Object is performed in the Execute script.

189 Implementing QuickScript.NET 189 An IF THEN block that determines when the amount of elapsed time has passed that exceeds the desired "calculation" period. Again, this determination is made by comparing two System.Int64 local variables: IF calcdelayl >= calcperiodl THEN The following local variable is of data type System.DateTime. System.DateTime is similar to System.TimeSpan except that it represents an absolute time in UDT. thisscan The local variable alcet (representing elapsed time) is determined using a.net technique that applies a method of the System.DateTime variable thisscan "Subtract," which back-calculates the amount of time elapsed between a previous time held in the variable lastscan and time of thisscan: alcet = thisscan.subtract(lastscan); The following line illustrates the use of another method of the.net System.TimeSpan object TotalSeconds, which facilitates calculation of percentages in this case. TotalSeconds actually returns 64 bit values and division of two 64 bit values keeps precision of 64 bits. The UDA is of type MX Float but.net implicitly converts from 64 bit to a proper float number. me.running.percentofclock = * ret.totalseconds() / cet.totalseconds(); Having performed calculation using local variables, it is important to get the values back into a UDA of category Calculated retentive to preserve it for another scan and for the Checkpoint files. The following example illustrates this, copying a local variables System.TimeSpan into an MX ElapsedTime UDA: me.clock.elapsedtime = cet; The calculations in next scans are dependent upon remembering the exact time stamp so the local variable gets a time stamp using the Now( ) function: lastscan = Now(); Note that this local variable lastscan is not copied to a UDA of category Calculated retentive. This is not necessary because lastscan is dimensioned as System.DateTime in the Declarations section. This means that it is active for the life of the $RunTime instance Object and its value is preserved from scan to scan. In a failover scenario it is not necessary to preserve its value because calculations must start over fresh with the Startup and OnScan scripts anyway.

190 190 Chapter 6 Documenting Your Classes Summary Document all Classes used in the project Interactions between scripts can be complex. This chapter has described some of the important concepts, including UDA scope, local variable scope, script execution order and interactions with other IAS Objects. Interaction with a database is the example selected for illustration in this chapter. However the complexity of ADO.NET and the propensity for database interactions to thwart simple timing logic points toward custom Function DLLs as the most effective script implementation. An IAS Object called SQLDataObject is available and can be used for many database interactions. Thus it is not absolutely necessary to resort to custom Function DLLs to communicate with a database. ObjectCachExt.dll was chosen as the example for this chapter because it also illustrates techniques for leveraging storage into memory using the Application Domain associated with the operation of the AppEngine hosting the IAS Object. QuickScript.NET offers a variety of script operational types - OnStartup, OnScan, Execute, OffScan, and Shutdown, and a variety of trigger types are possible for the Execute operation using a versatile trigger Expression. The timing of repeat cycles can be configured and the Run asynchronously check box option allows an Execute script to overcome the confining limits of an Engine scan. This becomes quite important when a script is attempting to perform programmatic interactions with off-engine processes like transactions with a database. Incorporation of programmatic access to the Microsoft.NET Common Language Runtime (CLR) is the most powerful aspect of the IAS scripting environment. The syntax of QuickScript.NET has been restricted to basic constructs given the lessons learned with the InTouch Software script language. QuickScript.NET adds some fundamental functions mostly per their definitions and behaviors taken from InTouch Software. The QuickScript.NET code examples in this chapter have been presented in a logical order and are somewhat complete, however they will not complete a functional set of Objects for the test case of communicating with a database. See Appendix B,.NET Example Source Code, for the complete definitions. This chapter also described the concept of time calculations and provided a brief example. This chapter has provided a glimpse into the QuickScript.NET environment using practical examples based on a real-world application. The complete listings for the Object templates and the C#.NET source code are found in Appendix B,.NET Example Source Code.

191 Architecting Security 191 CHAPTER 7 Architecting Security Wonderware works closely with Microsoft and industry standards organizations like the OPC Foundation to involve multiple vendors in an industry-wide approach to solving security problems. The success of a Control System Security Solution is enhanced by pooling IT expertise and Control System Operations groups during the implementation and integration phases of a FactorySuite A2 System project. This chapter provides a high-level Security perspective, and specific recommendations within the FactorySuite A2 System environment. Contents Wonderware Security Perspective Securing FactorySuite A2 Systems Securing Visualization Securing the Configuration Environment Distributed COM (DCOM) Security Recommendations Summary

192 192 Chapter 7 Wonderware Security Perspective Information Systems in manufacturing facilities are evolving rapidly. The evolution of these information systems is driven by manufacturers need to integrate with business/erp and production systems, provide access to production data across the enterprise (both from inside and outside the environment), and reduce system maintenance costs. Security risks also evolve as new vulnerabilities and targets are discovered in the various systems. Numerous incentives exist to protect a control system: The technical knowledge, skills and tools required to penetrate your IT and plant systems are widely available. Regulatory mandates and guidelines issued by the US Government (National Strategy to Secure Cyberspace -US Government page 32). Guidelines and best practices for securing plant control systems from advisory groups, such as ISA SP99 committee, NIST (Process Control Security Requirements Forum -PCSRF), NERC, etc. Wonderware's approach to site network(s) and control system security is driven by the following principles: View security from both Management and Technical perspectives. Ensure security is addressed from both IT/IS and Control System perspectives. Design and develop multiple network, system, and application security layers. Ensure industry, regulatory and international standards are taken into account. Prevention is critical in plant control systems, supported by detection. Realizing these principals is accomplished by implementing the following Wonderware Security recommendations: Maintain a prevention philosophy to support security policies and procedures using the following security components: Firewalls Network based Intrusion Prevention/Detection Host-based Intrusion Prevention/Detection Include a clearly defined and clearly communicated change management policy (for example: firewall configuration changes). Converge IT and Plant networks. Maintain secure and insecure protocols on the same network.

193 Architecting Security 193 Enforce monitoring, alerting and diagnostics of plant network control systems and their integration with the corporate network. Move to an off-platform data collector in a DMZ. Retain forensic information to support investigation/legal litigation. Enable/Ensure secure connectivity to wireless devices. Common Control System Security Considerations Many process control networks have been implemented in pieces. Most of these systems lack a consistent security design and many were not designed to include security configuration. When securing a control system, the number one criteria is defining and understanding the information/data that needs to be secured. In doing so, potential vulnerabilities are identified. The vulnerabilities may be the result of practices adopted primarily for convenience. Once identified, vulnerabilities may be removed or altered to increase security with no impact on production operation performance. Areas of focus include: Multiple remote access points. Information queries that can be deferred or accessed though a DMZ/off control network, etc. Common Security Evaluation Topics The following security topics must be evaluated and should be critical parts of an effective security strategy: Policies and Procedures Security policies and procedures are the foundation of a solid security strategy. Many automation, control, and access areas must have well-defined security policies and procedures. The security policies and procedures (and their enforcement) will have a profound effect on enhancing automation and control system security. Accounts Types and uses of security accounts needs to be defined by strong security policies and must comprise useful account creation and maintenance procedures. The policies that govern system accounts should be fully developed, documented and communicated by IT, Automation engineering, and Management in a collaborative environment.

194 194 Chapter 7 The following items must be considered when developing or reviewing account policies: Only validated users have accounts. Users' IDs must have unique names with strong passwords. Individuals are accountable for the use of their User ID. User access should be restricted as much as possible. Make sure that account lockout duration is well defined. Groups should be defined by user access needs and roles. Guest accounts and default vendor accounts should be removed or reset as applicable. Process Operator station accounts should be limited and defined by operational area. Service accounts should exist on the local Domain or local machine and should not be used to logon to a server. Passwords Passwords are one of the most vulnerable security components. This security vulnerability is largely eliminated by defining a solid password policy and configuring your system to enforce the policy. Using complex passwords (and changing them regularly) minimizes the likelihood of unauthorized access to the control system. The following list provides guidelines for effective password management: Enforce password history to limit the reuse of old passwords. Enforce password aging to force frequent changing of passwords. Enforce minimum password length to reduce password guessing. Enforce password complexity requirements to reduce password guessing. Ensure passwords are not stored using reversible encryption. Remote Access The need for access to process information, configuration information and system information from outside of the systems domain is common. Welldefined policies and procedures to manage remote access to the system by other company business units and or suppliers and venders greatly reduces the possibility of security threats penetrating the system. The following list contains guidelines for remote access: Limit access as much as possible by defining different access levels based on need (job function). Enforce mandatory PC checkups of any equipment that is brought onsite. Configure a separate role-based user group for temporary accounts and review this user list often. Define and document all outside system access routes and accounts.

195 Architecting Security 195 Physical Access Most production facilities have physical security plans in place. These plans should be an integral part of an overall security program. By not allowing unchecked computers and unauthorized users to have access to critical infrastructure components, many security threats can be eliminated. Critical process control components such as servers, routers, switches, PLCs, and controllers should be protected under lock and key and have personnel assigned who are directly responsible for the components. Backup and Recovery Plan The Backup and Recovery plan is a critical security component. Recovery from any level of failure due to either a security or natural interruption of the system must be included in the security policy. The following items must be considered when defining a backup and recovery plan: Define and document how each part of the system will or can be backed up. Ensure backups are included in routine system maintenance plan and when improvements or other changes to the system occur. Document backup procedures for all system configurations and assign administrative responsibility to appropriate personnel. Document and keep current all versioning of system software and hardware. Provide a protected off-site repository for copies of all system backups Provide a documented escalation plan for recovery and documented processes assigned to qualified personnel for implementing a recovery. Virus Protection Add an additional security level at each access point of the system by defining where and what virus protection is to be implemented. Document the proper configurations for the virus protection software. Mandatory virus definition file updates are essential. Note For a list of ArchestrA-related file exclusions, see "Configure Anti- Virus Software" on page 283. Security Patch Implementation Security patch management is a critical evaluation topic that has the largest impact on Microsoft Operating System-based Supervisory and Control Systems.

196 196 Chapter 7 Careful planning and attention to detail is required when developing and documenting your procedures and policies for implementing security patches. Request a detailed support plan from each automation vendor and security software vendor, and review them with the goal of inclusion as part of any security patch management procedure or policy. About Security Infrastructure Components The security infrastructure comprises many components that support the supervisory and control system. Each component needs to be reviewed and defined by critical value and attack vulnerability. Policies and procedures must then be defined that provide auditing and maintaining the security levels of each component. The components are listed below. Note Each component should also be reviewed for possible redundant configuration to improve availability and protect against the system becoming unavailable due to a single failure. For detailed information on Industrial Application Server redundancy configuration, see Chapter 3, "Implementing Redundancy." Authenticators System users could be actual operators and engineers, or other systems or services that run internally or externally to the Supervisory Control System. All known users must be accounted for and defined authentication methods and procedures should be developed to reduce the risk of unauthorized access to critical systems or protected information. Security Policy Enforcement Components Each device or software package that is deployed for security policy enforcement must be defined by enforcement type and its impact to system on failure. These components include, but are not limited to, Firewalls, Routers, Switches, and Operating System Services. Any enforcement component that is defined as critical should be deployed in a redundant configuration if possible. Firewalls, Routers, Switches Firewalls, Routers, and Switches are an integral part of Supervisory and Control systems. Firewalls provide for a way to isolate and control communication between segments of a network and between operational units. A detailed understanding of communication ports, IP addresses, and protocols needed for the Supervisory and Control system to function properly is critical for the success of the Security policy. By defining solid policies and procedures for firewall configuration, operation, and auditing, you can limit your communication to specific ports and IP addresses that allow only authorized communication between systems.

197 Architecting Security 197 Additionally, defining solid policies and procedures for Router and Switch configuration ensures management of where information and access is permitted along with control over bandwidth. Optimal network utilization can then be achieved. Although firewalls, routers, and switches have overlapping capabilities, each device should be used for its base functionality: firewalls should be used to control communication types, routers should be used to forward communication by routing protocols along a proper route, and Switches should be used to manage bandwidth by controlling communication flow between ports and avoiding packet collisions. Domain Controllers The use of services such as Microsoft Active Directory provides management and enforcement of access security for users, groups, and organizational units. Not all software supports domain-level security. For example, some automation software will require local PC or even package- or AutomationObject-level security to be defined and implemented. Check the product documentation carefully before deployment. Physical Networks The basic building block of a supervisory and control system is the physical network itself. Special attention should be given to the design, selection of media, and installation of the network. A careful review of any installed network segment should be undertaken before extending or adding components. By making sure redundant paths and proper distances are observed, slow and unreliable communication can be avoided. All networks should be reviewed for live unsecure ports and exposed segments that could be tapped. With the complete network layout documented, recover plans can be defined to improve system available in the case of an accident that takes down part of the network. Remote Access Devices Policies and procedures should be developed to control the installation and use of modems for remote access. A very good alternative to allowing modem access is to implement Virtual Private Network (VPN) access. If a modem has to be used for remote access a good rule is to require dial back connections.

198 198 Chapter 7 Wireless Access Wireless technologies are quickly becoming part of Supervisory and Control Systems. Wireless security has a lot of underlying topics that should be discussed. The following topics should be taken into consideration when defining a wireless implementation: Access can be limited to unwanted areas through the use of directional antennas. Utilize more than the industry-standard WEP ("Wired Equivalent Privacy") protocol. Use a solution based on 802.1X, Extensible Authentication Protocol (EAP), and Wi-Fi encryption. Review implementation guides from your Wireless device vendor and from your operating system vendor. Software The software components of a supervisory and control system can have a large impact on the security of the overall system. When reviewing the security features of the software that will be deployed within a production facility, each component should be evaluated as an integrated part of the complete system. All software components should leverage the capabilities of the infrastructure and support configurations that meet the policies and procedures that are defined as need to secure the system. By reviewing all software from a secureability standpoint, policies and procedures can be established to audit the system and maintain high levels of security. Virus and Malicious Software Protection With the many Host-based protection system options available on the market today, one must ensure that when selecting this protection component that all Supervisory and Control system software is compatible and that the vendor provides timely updates. Host-based protection software should also provide protection for other malicious software such as Spyware, Malware, and Adware. Intrusion Protection and Prevention Intrusion protection and prevention has become a viable way of raising the security level within a TCP-IP LAN or WAN infrastructure. Intrusion Detection Systems monitor network traffic and generate alerts when malicious traffic or repeated password guessing is detected. These tools have been employed by IT department for many years. Intrusion Prevention technology has become the preferred method to detect and alert when hacking or virus/worm attacks are present, as well as block such attempts by managing firewall policy, Switch ports, Router paths, and trapping s before damage can be done.

199 Architecting Security 199 The implementation of an Intrusion detection or Prevention system on a Supervisory and Control network does include risk. The following list explains some considerations when evaluating their use in a particular environment: The system should provide centralized reporting and management. The system should provide multiple ways to deliver alerts. Evaluate the supported level of signature-based identification of malicious or anomalous traffic. Connection Flood (denial of service) controls should be included. The system should support Alert-only mode for tuning. The system should support the software and application that you have installed or going to deploy. The system should enable creation of your own policies. Evaluate supported bandwidth and connections. Because Intrusion detection and prevention system can present a risk to functionality and operation of a Supervisory and Control System, a welldeveloped design with strong policies and procedures should accompany any implementation plan. Operating Systems Review the base operating system that hosts all of your Supervisory and Control applications for proper deployment, configuration, and security patches. The initial focus should be reviewing installed components and configured users. Microsoft provides detailed guidance for locking down your operating systems so that security threats can be managed and eliminated. By defining what Supervisory and Control software is to be deployed to a system, you can define the level of lock-down, and at the same time ensure full functionality of manufacturing applications. Databases Database applications such as Microsoft SQL Server have become a common component of all manufacturing systems. Because of the need to allow access to database information, and the need to update and append the information, you must be very deliberate in the approach to locking down a database. Provide a detailed mapping of users (people and services) which require access and define usable database security policies.

200 200 Chapter 7 Securing FactorySuite A 2 Systems The ability to secure a FactorySuite A 2 System is directly related to the infrastructure (Servers, Workstations, Ethernet Cables, Fiber Optics, Switches, Routers, Firewalls, etc.) as well as the hosting software (Operating systems, Virus protection, Intrusion protection, etc.). ArchestrA-enabled nodes use DCOM for their communication "backbone." This section is designed primarily for Process Control Engineers and IT Professionals who are familiar with standard IT practices, Windows Domain Engineering and Administration, and Process Control or SCADA Environment requirements. Content is derived from Wonderware testing documentation. Security Considerations The following section summarizes the security considerations within a production environment, and describes recommendations as applied to a Process Control Network (PCN) or SCADA System (WAN). Secure Layers Divide the system into secure "layers." In the security context, a layer can be defined as a division of a network model into multiple discrete layers, or levels, through which messages pass as they are prepared for transmission. All layers are separated by a router or smart switch device. A secure layer is further defined by the need to allow or restrict access and the criticality of the sub-system. An Intrusion detection system is deployed in higher- risk layers. The following figure is designed to show a representative topology; it is not intended to depict an actual Plant System topology. It includes the following named layers: Corporate Network Infrastructure. Process Control Network (PCN). Remote Domain Network (adjunct to PCN). Remote Legacy Workgroup (adjunct to PCN).

201 Architecting Security 201 Note that all layers (represented by the main backbone) are separated by firewalls and routers: ` ` ` ` Notes All IP Addresses are assigned by DHCP Reservation ActiveFactory Client ( http ) SuiteVoyager Client ( IE Browser ) Thin Thin Client Dev Client HMI ( TS Client ) ( TS Client ) Corporate Network Infrastructure (CorpNet) Corporate IT Functions Gateway Non-DHCP Server Assigned at Domain Controller Gateway Application Object Server Historian Node SuiteVoyager TerminalServer Galaxy Repository Firewall Domain Controller Process Control Network (PCN) Non-DHCP Server Assigned at Domain Controller Monitored DO Line Optional Firewall Engineering Station ` ` Visualization PLC Gateway DHCP Server (RAS to DC) Gateway Firewall Gateway DHCP Server (RAS to DC) Gateway Router Slow Connection Remote Domain Network Modem SCADAlarm Remote Legacy Workgroup ` PLC Application Object Server Site1 Legacy Visualization VisualSite ` Failover Comm AOS1Site AOS2Site PLC2 FactorySuite Software Applications Wonderware software applications have been tested in a wide variety of security-related implementations similar to the previous figure. The figure represents the widest usage scenarios of product combinations, which were tested in various scenarios involving limited- or no DCOM connectivity, limited port ranges, narrow firewall settings, and highly routed environments. Certain Wonderware software applications like InTrack, InBatch, and InControl utilize a high degree of connectivity to the Corporate ERP System and Process Control Enterprise, along with the associated distributed computational and remote services requirements. These applications could be adversely affected if unlimited DCOM connectivity were not present. The layers and port listings are detailed below. Note For application-specific communication requirements, see the online or specific Deployment Guide documentation for that application.

202 202 Chapter 7 Corporate Network Infrastructure Layer The majority of communication between computers on a corporate (business) layer is accomplished using viewers, proxies, or interfaces like Microsoft Internet Explorer. These engines use HTTP or HTTPS (secure http) protocols to transmit and receive data. This data can be secured, filtered, and carefully monitored. For the most part, only traffic with proper credentials or limited functionality is allowed to pass. RPC traffic, or Remote Procedure Calling (required with DCOM) is rare between business nodes. Closing DCOM ports for added security at this level can be effective, since the most desktop applications do not use many, if any, DCOM objects, and therefore do not require ports to transport information. Corporate Network Firewall Ports The following table describes the firewall ports necessary for successful communication between business nodes. The following table references the previous figure: Function Port HTTP TCP 80 HTTPS TCP 443 Remote Desktop Connection TCP 3389 Process Control Network (PCN) Layer The Process Control Network (PCN) Layer contains the production nodes (Data Servers, AppServers, etc.) that process and store all production data. This layer requires that all nodes have unrestricted access to each other, in order to process the data in real-time. Data sources are represented in the previous figure by the Legacy and Remote Domain "sub-layers." These layers may also represent geographically distant sites which may be leased to other enterprises, and whose data is required by the parent company.

203 Architecting Security 203 Process Control Network Firewall Ports The following table describes the firewall ports necessary for successful communication between ArchestrA-enabled and production nodes: Function Primary Connection Secondary Remarks Connection CIFS TCP 445 Outbound File serving, deploying. From IDE to IAS. NETBIOS Datagram UDP 138 Send Name Service/Browsing. From IAS to Browse Master or from Browse Master to Domain Master Browser. NETBIOS Name Service UDP 137 Send Receive Name Service/Browsing. From IAS to WINS Server or Browse Master or Domain Master Browser. NETBIOS Session TCP 139 Outbound Server Message Block (SMB). Used to implement Windows networking from IAS to the Domain Controller if applicable. NMXSVC TCP 5026 Outbound Archestra Communication Channel. Peer-to-Peer, bidirectional between all ArchestrA-enabled nodes. RPC DCE TCP 135 Outbound DCOM. Peer-to-Peer, bidirectional between all ArchestrA-enabled nodes. RPC Dynamic Port Range TCP * Outbound *Custom range. Peer-to- Peer, bi-directional between all ArchestrAenabled nodes. SQL Server TCP 1433 Inbound SQL Server. From SQL Server to Client SQL Client TCP 1433 Outbound SQL Client. From Client to SQL Server SQL Browser UDP 1434 Send Receive Only if implementing SQL Server instances SUITELINK TCP 5413 TCP (see note below) Suitelink: Intouch, IO Server communication. PING ICMP Protocol Type 8 Between all ArchestrA - enabled nodes.

204 204 Chapter 7 Function Primary Connection Secondary Connection Remarks NTP UDP 123 Time Synchronization. From Client to Domain controller(s) or time master. DNS UDP 53, TCP 53 Domain Name Service. From client to DNS Server. LDAP TCP 389 Active Directory Domain, from client to Domain Controller(s) KERBEROS TCP 88 Authentication Note SuiteLink establishes a secondary connection in the disclosed port range. Stateful packet inspection firewalls handle this operation automatically. If the user needs to establish this on their own, they are then aware of the secondary connection ports. For more information on configuring port ranges, see Microsoft articles Q154596, Q300083, and Q Securing Visualization Users with different roles require different user interface experiences. Typical interface experiences include window-to-window navigation, data visibility on a specific window, and restrictions on visible actions. Each of these actions are easily achieved by animation links in InTouch Software. The animation links (typically) test the InTouch Software system tag $AccessLevel. While this implementation works, it provides a very linear security model. Industrial Application Server roles offer more flexibility and can be leveraged from InTouch Software by using the IsAssignedRole ("RoleName") script function. When executed, this function determines if the currently logged-in user is assigned to the role that was entered into the script call. This function allows the InTouch Software application to access the role-based security of ArchestrA IDE. To implement this, add a Data Change script to InTouch Software that executes any time the InTouch system tag $Operator changes. For example, the following script could be called when the $Operator tag changes: AdministrativeAccess = IsAssignedRole("Administrator"); SetpointAccess = IsAssignedRole("Engineer"); ManualAccess = IsAssignedRole("Operator"); In this example, AdministrativeAccess, SetpointAccess, and ManualAccess are Discrete InTouch Software memory tags. Users can possess multiple roles and more than one of these discrete tags could be set. You can animate the InTouch Software application by using these tags in the expression statements of the animation links.

205 Architecting Security 205 This implementation has the following advantages: First, the scripts execute only when the user changes. Instead of running the same script for every animation, it only runs as needed, which improves overall application performance. This also improves the draw times of the screen are also improved, since it is not necessary to evaluate the user rights for each associated animation. The second advantage is in maintenance. By having the script appear in one location, there is only one place to go to make required changes. If, in the previous example, all Manual Control was no longer allowed by Operators, but instead this permission was only going to be given to Engineers, this can be achieved by a simple change. You would change the third line of the script to read: ManualAccess = IsAssignedRole("Engineer"); This change would only be made in the $Operator Data Change script, instead of every Manual Control animation. OS Group Based Security Mode Notes The OS Group Based security mode enables user authorization based on OS Groups; in other words, this mode leverages the operating systems' user authentication system on a Group basis. This means that the user is a member of a particular group and has certain permissions within the context of that group. Two settings are available in this mode: Login Time, and Role Update. The default value for the Login Time setting is 1000 ms. The user will experience a 1 second delay while the system validates the login permissions. The default setting for Role Update setting is 0 ms., which means the system does not pause between validating user membership and groups. This setting is independent of the Login Time. System Considerations The first time a user logs on to a system (using InTouch Software, for example), and the OS Group Based mode is set, the login is validated at a Domain Controller. After the login is validated, a cache is created on the local machine and propagated to other nodes in the system. The user then has specific permissions to interact with the system (operator, administrator, etc.) on any node. This scenario has several implications: The first time a user logs on to the system, they may experience delays while the system validates their permissions and creates the cache. This is especially relevant if the system includes a large number of Groups, and/or network nodes. This delay may be exacerbated by widely-distributed networks (see the last bullet).

206 206 Chapter 7 Subsequent logins in the system use the (local) cache created at the previous login. This means that if login permissions are modified, the user can still log on, but uses the "old" cache until the update occurs. This update operation takes place "under the hood" and does not prevent the user from logging in with the old permissions. If the Login Time is set to 0, the system validates permissions and creates a new cache at each login. When the security mode has a large number of groups, and the system is widely-distributed (SCADA) with slow or intermittent network components, lengthy login delays may occur. To mitigate login time delays Provide additional Domain Controllers on "this" side of potential network bottlenecks. Ensure the Login Time and Role Update settings are set correctly for the local environment. For example, setting the Login Time to 10,000 ms means that the user cannot interact with the system for 10 seconds, regardless of the use of the validation cache. In this case, 1000 ms (default) is usually acceptable. Securing the Configuration Environment The ArchestrA IDE extends the security models of traditional industrial automation applications to incorporate the configuration actions as well as the run-time actions. When a Galaxy is created, the administrator can authorize only those who need configuration permissions. Additionally, the administrator can limit an IDE user's permissions. This capability can be used in an efficient way to manage a team of engineers who will be building an application together. For example, if a senior engineer is the person responsible for creating the project standards, a role could be created that has the capability of editing the templates. Another role could be created that does not have the permission to edit the templates, but can use the templates to build the application. A junior engineer would be given the latter role. Each object maintains an audit trail of user actions performed against that object. This helps to track the versions being used and the progress of building the application, as well as provides a record of changes. This audit trail can be viewed in the IDE by accessing an object's properties.

207 Architecting Security 207 Distributed COM (DCOM) DCOM enables communication between objects on different computers on a LAN, a WAN, or the Internet. It uses most transport protocols (TCP/IP, UDP, etc.). Limiting the DCOM Port Range Closing or limiting DCOM port ranges is a common IT recommendation and practice at the Process Control Network layer. The intent in closing or limiting port ranges is to make them "obscure" to attackers and various worms and malware by hiding which ports actually are open. This simple solution is a perfectly appropriate and highly-effective security practice in some select cases, where a specific process control environment requires a specific number and type of highly-screened agents to interact with the system. For example, public utility production plants (like water and sewage treatment plants) often have relatively small staffs, who have limited interaction with a relatively slow-changing process control environment. The environment may also include out-of-spec process alarming and historization of data and interaction. This environment provides a secured environment that is extremely long-lived, relatively static, and highly effective. Note Such systems are usually designed to meet exacting specifications at the beginning of the project, and reviewed/updated to current standards when major engineering changes are integrated into the system. However, in most production environments, closing DCOM ports may limit or stop necessary communication and telemetry needed for the parallel computing environment within a Process Control Network or SCADA System. Such limited communication has the potential to create conditions within the plant that can cause intermittent/permanent loss of process data, unexpected operation, or loss of control of the environment resulting in dangerous or deadly conditions. Further, the application of certain registry settings and the creation of specific ActiveDirectory rules and secure zones can create conditions within specific operating systems which WILL require reinstallation of the Operating System in order to successfully roll back a previously undefined key, policy, or setting to the previous state of non-definition. Establishing definitions for undefined registry values may render an Operating System unusable in a Process Control Environment. The only correction is to reinstall the operating system and reset the software benchmark for the affected machine(s). The majority of port numbers between 1024 and are assigned to various individuals and organizations. A certain percentage of these ports will not be encountered on a Windows Operating System. However, certain 3rd party vendors applications may be affected by limiting the access to those ports by using dcomcnfg.exe or specific registry entries in an untested and non-qa'd security profile (in addition to Wonderware Software).

208 208 Chapter 7 In most production environments, blocking ports will completely break the functionality, intelligence, and operational ability of the distributed computing environment. Security Recommendations Summary Modern industrial automation requires direct interaction between machines performing specific functionality within an intelligent enterprise. Limiting the communications between production nodes across an enterprise WILL ALSO limit the functionality and performance of the enterprise and in some cases make the enterprise unsupportable. Extreme care should be exercised when modifying any communication protocols, communication channels and ports, or operating system processes and services within a Process Control Environment. Proposed changes to the Process Control Environment should be tested and modeled on a Shadow System or plant model system before being implemented within the operating PCN or SCADA System. For more in-depth information regarding designing secure Process Control environments, refer to specific Wonderware product deployment guides, Wonderware Training Seminars, and to Wonderware Enterprise Security Guidance documentation. Note For more information regarding DCOM, see For information on assigning a specific/dynamic port range, and securing the RPC ports using IPsec, see

209 Historizing Data 209 CHAPTER 8 Historizing Data Data storage in the FactorySuite A2 System environment is handled by IndustrialSQL Server Historian. The individual historized data points are defined as attributes of ArchestrA ApplicationObjects. This chapter describes how the Historization component can be applied in the FactorySuite A2 System environment. Note IAS and IndustrialSQL Server have specific version compatability requirements. Check the FactorySuite A2 Compatibility Matrix on the FactorySuite support website for detailed compatability information. Contents General Considerations Area and Data Storage Relocation Non-Historian Data Storage Considerations

210 210 Chapter 8 General Considerations When designing a FactorySuite A 2 System-based industrial automation application, consider the following data storage concerns: Data Point Volumes: The volume is the number of points in the application that will be historized. In IAS, data points are object attributes that have history enabled. Data Storage Rate: At what rate will the data be changing and how quickly will that data need to be stored? Data Loss Prevention: What are the possible scenarios that would result in a loss of data? Storing System Data: In a system with multiple historians, how does changing system topology affect the location of stored data? Client Locations: As you plan the network topology for your application, you should consider the location of history clients. User Account: The user account under which services run must be the same for all applications. Also, if you specify a local computer user, then the Historian Node must be in the same network domain or workgroup as the AutomationObject Server node Data Point Volumes The data storage rate of a single historized attribute (i.e. point) is a function of the scan period of its hosting AppEngine and its rate of change. The attribute can be stored no faster than the AppEngine scan rate, and will only be sent to the historian if it changes. For analog attributes, a deadband can also be configured to prevent storage of insignificantly small changes. Finally, attributes can be configured to ensure that slow-changing or nonchanging attributes are always stored at a minimum interval (such as once per hour) via the force storage period. The volume of data points that must be stored is a determining factor in deciding how many historians will be required in an application. Most applications will only require one historian. Very large applications may require multiple historians. IndustrialSQL Server Historian has been vigorously tested, and can handle the historization of up to 150,000 individual points. If your requirements exceed this number of points, you should plan to incorporate multiple historians in your application topology.

211 Historizing Data 211 Data Storage Rate When configuring a data point for storage, it is possible to set a rate for that point to be stored. The limiting factor on this storage rate is the scan rate of the AppEngine: The data can be stored no faster than the AppEngine scan rate. Data storage cannot occur between AppEngine scans. The data storage rate should always be whole multiples of the AppEngine scan rate that hosts the associated object. Data Loss Prevention The ArchestrA framework protects historized data from loss. This is done by storing the data locally to disk when connection is lost to the Historian. This operation is called "Store Forward." Each AppEngine and Platform is capable of storing all of the associated acquired historical information to disk when a connection to the historian cannot be established. Once the connection is reestablished, the data will be sent to the historian. It is important to ensure that the AppEngine responsible for sending the data to the historian is not interrupted. The following is a list of precautions to prevent data loss: Separate the Galaxy Repository from running AppEngines. As applications grow large, the configuration changes to that application will become CPU-intensive. It may be possible to have the configuration services on a computer starve the AppEngine from the required CPU cycles to perform the data storage. To prevent this, place the Galaxy Repository on a remote computer from running AppEngines. Do not deploy to running AppEngines. If an AppEngine is running and gathering information for the historian, deploying additional objects to the AppEngine will cause a momentary interruption of the AppEngine execution. During that time incoming data changes may be missed. This effect can be prevented by only deploying new objects during noncritical data storage periods. Deploying large numbers of objects can be particularly impactful. Be sure that DCOM is enabled for both the MDAS and IndustrialSQL Server Historian computers and that TCP/UDP port 135 is accessible. The port may not be accessible if DCOM has been disabled on either of the computers or if there is a router between the two computers that is blocking the port. For more information, see "Process Control Network Firewall Ports" on page 203. Area and Data Storage Relocation The System topology will evolve throughout the application's life cycle. As this evolution takes place, you must determine the data storage implications. The ArchestrA framework was built with flexibility as a target goal. It is very easy to move an entire Area of objects from one AppEngine to another. But it is important to remember that the AppEngine defines where the historical data for hosted objects will be sent. If using multiple Historians, and the topology is modified, there may be an impact on the location of stored data.

212 212 Chapter 8 When designing the system topology, note that the locations of the historical data clients may impact the end design. This is particularly true when portions of the application are separated by low bandwidth or intermittent network connectivity. Client applications should not be required to access the historian over these poor connections. One solution to this is to have local historians that service the computers that are locally situated with good network connections. Non-Historian Data Storage Considerations As a system is put into service, it is normal to maintain the Historian node to ensure enough space is available for continued data storage. This is a requirement for any historian. However, the IndustrialSQL Server Historian is not the only storage mechanism that is used in a FactorySuite A 2 System. Nodes other than the Historian Node are capable of storing large amounts of information, so it is important to assess the impact of the following settings on data storage: Alarm buffer Size: If the network connection to the alarm database is lost, the alarms will begin to be stored in a local buffer. This buffer is a direct reflection of the page file size. An average alarm record is 1400 bytes of data. If the buffer fills up, storage will stop. However, a 10 MB page file can store over 3500 alarms, so using the proper precaution can easily prevent an issue. Log Viewer Event Storage: By default the Log Viewer event storage mechanism (which is installed on all computers) is set to use a maximum of 5 GB of storage. You can adjust this value. The Log Viewer event storage must be considered in the total disk space requirements. Store-and-Forward Deletion Threshold: If network connection to the historian (IndustrialSQL Server Historian) is lost, the historical data will begin to be stored in a local directory. The default circular deletion threshold is 100 MB. You should consider your requirements for this setting, and adjust it, if necessary, in the WinPlatform or the AppEngine object configuration. When evaluating system configuration, it is worth spending a little time up front to consider disk space availability.

213 Implementing Alarms and Events 213 CHAPTER 9 Implementing Alarms and Events The Alarm and Event subsystem consists of both Alarm Consumers and Alarm Providers. When determining the topology for your application, be aware of how alarm and event messages are processed within the system and how different configurations can affect system performance. Note The event messages produced by Alarm Providers are not the same as events generated by the IndustrialSQL Server Historian system. General Considerations Configuring Alarm Queries Determining the Alarm Topology Logging Historical Alarms

214 214 Chapter 9 General Considerations The Platform object serves as an Alarm Provider for all IDE objects and is the primary Alarm Provider in a FactorySuite A 2 System. The Platform is capable of providing any alarm in the Galaxy; that is, the Platform is not limited to the alarms generated by the objects it is hosting. The network load can be affected by which Platforms are set as the Alarm Providers. By default, when a Platform is configured as an Alarm Provider, it will automatically subscribe to all alarms in the Galaxy. This means that any time a new alarm occurs, it will be sent to all of the Platforms that have been configured as an Alarm Provider. You can override this by configuring the Platform to be only an Alarm Provider for a set of Areas that you designate. The alarm consumers provided with FactorySuite A2 System are the InTouch Alarm Viewer ActiveX Control and the InTouch Alarm DB Logger Manager utility. These consumers can be configured to query alarms from a local Platform or from a remote Platform. By leveraging this flexibility, you can minimize the network load imposed by alarm distribution. Note The InTouch Software alarm clients used to show summary alarms only query for alarm information when they are visible on the screen. Configuring Alarm Queries For an Alarm Consumer to obtain the alarms from an Alarm Provider, it must query the Alarm provider. A typical alarm query is configured as follows: \\ProviderNodeName\Provider!AlarmGroup For a FactorySuite A2 System-based application that uses the Industrial Application Server, these translate as follows: ProviderNodeName - This is the host name of the node where the Alarm Provider resides. Provider - This is the word "Galaxy." There can only be one Platform per computer, and this keyword represents the Platform Alarm Provider. AlarmGroup - The Area objects in the IDE serve as the alarm groups. When building the application in the Model View of the IDE, you can place the Areas within each other. If an Area named "Tanks" hosts another Area named "Clearwell," then subscribing to the alarms in "Tanks" will automatically include the alarms in "Clearwell." Multiple Queries - An Alarm Consumer query can be used to query multiple Alarm Providers by adding a space between the individual query strings.

215 Implementing Alarms and Events 215 Determining the Alarm Topology When you are determining the alarm topology, it is important to take into consideration the overall topology of the system. Alarming can be implemented using Distributed Local Network or Client/Server topologies. Best Practice Be sure that parent alarm areas are on the same node as their subareas. For more information on Distributed Local Network or Client/Server topologies, see Topology Categories in Chapter 2, "Identifying Topology Requirements." Alarming in a Distributed Local Network Topology In a distributed local network topology, the nodes that serve data (AutomationObject Servers) are not separated from the clients that consume data (Visualization nodes). Each node hosts both components locally. A Platform is deployed to each Workstation node (which is a combination of AutomationObject Server and Visualization node). It is more likely that every Platform in this topology is configured as an Alarm Provider, and each of the Alarm Consumers queries the local Platforms for alarms. Consider the scope of interest of each Platform. When configured as an Alarm Provider, the Platform requests all alarms in the Galaxy by default. If a workstation does not need to view all of the alarms in the Galaxy, the Platform on that computer should be configured to only subscribe to alarms that are within the scope of interest. Best Practice The following list summarizes the key points in setting up an optimized alarm distribution system in a Distributed Local Network topology: All of the Platforms on workstations will be Alarm Providers. If operators at a workstation will need to view all alarms in an application, you use the default scope for the Platform Alarm Provider on that node, which is to subscribe to all alarms in the Galaxy. If operators at a workstation do not need to view all alarms in the Galaxy, configure the Platform Alarm Provider scope of that node to subscribe only to alarms that are of interest to the operators at that node.

216 216 Chapter 9 Alarming in a Client/Server Topology The client/server topology separates nodes that serve data (AutomationObject Server nodes) and the clients that consume data (visualization nodes). There more clients than servers. A Platform object must be deployed on each client and each server. One or more of the Platforms on the AutomationObject Servers should be set as an Alarm Provider and each Alarm Consumer should query one of the AutomationObject Server Platforms directly. This deployment minimizes the network traffic by channeling the alarm traffic to specific Alarm providers. If the Platforms on the Visualization node(s) are set as Alarm Providers, each of those Platforms requests all alarms continuously, loading the network with unnecessary traffic. While a Platform can be configured to subscribe only to alarms of particular Areas, the Platform still requests the alarms for the configured Areas on a continual basis. By configuring the AutomationObject Server Platforms as Alarm Providers, only one node requests alarm updates. The Visualization node(s) only request alarms when a window containing the alarm display is active. Alarm consumers only request the alarms that are required to satisfy the alarm query. As stated previously, each Platform is capable of providing all alarms in the Galaxy. However, if all of the consumers are using a single Platform as the sole Alarm Provider in the Galaxy, there is a single point of failure for all Alarm Consumers. Also, the single Platform would constantly be receiving the alarms from all of the other AutomationObject Servers, which would cause a heavy traffic load on the network. If your client/server architecture consists of more than one AutomationObject Server node, take the following measures to ensure the highest availability of alarm information to the Alarm Consumers: 1. Configure the Alarm Consumer queries to query each AutomationObject Server Platform for the Areas that are hosted on that Platform. 2. Configure the AutomationObject Server Platform Alarm Providers to provide only alarms for the Areas hosted by that Platform. These two configurations lower network traffic between AutomationObject Servers due to alarm distribution and ensure that no one AutomationObject Server is a single point of failure for alarm delivery to the consumers on the Visualization nodes.

217 Implementing Alarms and Events 217 Best Practice The following list summarizes the key points for setting up an optimized alarm distribution system in a client/server architecture. The list also applies to a Widely-distributed SCADA system environment: The Platforms on the Visualization nodes should not be Alarm Providers. The Alarm Consumers on the Visualization nodes should query each AutomationObject Server individually for the Areas hosted by that Platform. The AutomationObject Server Platform Alarm Providers should be configured to only be providers for the Areas that are hosted by that Platform. Note For information on Alarm configuration in a widely-distributed SCADA environment, see "Alarms" on page 262. Logging Historical Alarms The InTouch Alarm Logger is an Alarm Consumer, and the Industrial Application Server Platform component is an Alarm Provider. The InTouch Alarm Logger is a component that stores the alarms it receives in either a Microsoft SQL Server database or into the Microsoft Data Engine (MSDE). The Alarm Logger can either be local or remote to the Platform that is the Alarm Provider. Best Practice In a typical FactorySuite A2 System, IndustrialSQL Server Historian will be used to store all time-series data. It is recommended that you install IndustrialSQL Server Historian on a dedicated node. For consolidation purposes, the best practice is to store the alarm history in another database on the same node as IndustrialSQL Server Historian. The location of the InTouch Alarm DB Logger utility may greatly affect data loss prevention. The Alarm Logger utility automatically buffers the alarms it receives until they are successfully stored in the target database. Installing the Alarm Logger on the AutomationObject Server node ensures that the alarms are not lost if the connection to the Historian Node is lost. To eliminate a single point of failure, install the Alarm DB Logger Manager utility on all AutomationObject Server nodes on which alarms are generated. The alarm query configured in the Alarm DB Logger Manager utility will then retrieve alarms that are generated only by objects hosted by the local platform. This practice ensures that no network connection will be required to deliver the alarm to the Alarm Logger and prevents the loss of alarm records due to network instability.

218 218 Chapter 9

219 Assessing System Size and Performance 219 CHAPTER 10 Assessing System Size and Performance This chapter provides sizing and performance data for FactorySuite A2 Systems. The data is based on extensive product testing and includes a predefined set of computer and application specifications. The specifications and results are intended as references. This chapter also describes basic testing topologies, including single-node implementation. Note The data contained in this chapter is provided as general guidelines for planning and sizing your system implementation and is not intended to be an exact predictor or specific guarantee of FactorySuite A2 System performance. Contents System Disk Space and RAM Use Predicting System Performance Performance Data Failover Performance Load Shared with Remote I/O Data Source DIObject Performance Notes OPC Client Performance

220 220 Chapter 10 System Disk Space and RAM Use The following information describes the effects of typical configuration and deployment tasks on disk space and RAM. Some of these tasks include object creation, deployment, and template derivation. The data provided in this section are examples; your system will produce variations from these numbers. Use these numbers for evaluation purposes and always allow for adequate spare disk and RAM capacity. Galaxy Repository Performance Considerations The ArchestrA database (Galaxy Repository) leverages Microsoft SQL Server functionality. SQL Server enables considerable discretion for configuring database growth and memory use thresholds. Database Growth Database growth can be set to either a fixed size, or to Auto Increment. The default setting (Auto Increment) is preferred unless: Specific IT requirements and dedicated GR management resources are in place in a specific production environment. FactorySuite A 2 System size is known with a high degree of confidence. The Auto Increment setting is effective for the GR Node because of the dynamic nature of the GR; in other words, the GR is not a "static" database that stores raw production values. An example of a "static" database is the ProdDB used by the PEM objects. The ProdDB is effectively managed using a fixed size strategy because its size can be more easily quantified and administered. The ProdDB database is also installed on the Historian node, distributing SQL Server processing needs. SQL Server provides effective growth administration engines and should not decrement system performance when dynamically growing the database, even when the AutomationObject Server is deployed on the same node as the GR.

221 Assessing System Size and Performance 221 RAM Allocation In practice, MS SQL Server tends to monopolize and consume any RAM that is available at any point in time. SQL Server enables setting a limit (or cap) on RAM allocation so that other system resources can function without limitations. This cap can be configured either as a dynamic or fixed setting. When the RAM allocation is known, select the...fixed memory size option to limit RAM use to approximately half of the machine's available RAM. For example, if a machine has 1GB of RAM, set the SQL Server cap to 500MB. Setting a fixed memory size ensures the memory is always available. Note For recommendations on Dynamic SQL Server memory allocation, see "Bulk Operations Considerations" on page 232. To set a fixed memory size 1. Start SQL Enterprise Manager. 2. Right-click the Server icon and select Properties from the submenu. 3. Select the Memory tab. 4. Select the Use a fixed memory size (MB) option. 5. Use the slider control to set the memory size. 6. Click OK to close the Properties dialog box.

222 222 Chapter 10 Auto Increment Data The following table illustrates the increased disk space used by the default Microsoft SQL Server Auto Increment setting, based on the starting size of a typical Galaxy Repository database: Auto Increment Catalyst Sizing MB Percent Increase Empty Galaxy Repository database size 6.6 MB Derive "X" number of templates or instances. Derive "X" more templates or instances. Auto-incremented size at reporting time. Auto-incremented size at reporting time. The default Auto Increment value is 10%. This means that the occupied disk space does not grow with each individual ArchestrA object template and/or object instance added to the Galaxy Repository. Instead, the disk space will grow by the specified percentage, when SQL Server determines that adding space is necessary. In practice, the growth increments for occupied disk space vary from 7% of the Galaxy database size to 11%. Note The size of the increase does not correlate to a single object instance. It is prudent to leave enough disk space available for the planned capacity of the ArchestrA Galaxy Repository. Always allow for 25-50% of projected/future capacity (unless the system is quite well-defined) then add 10% to allow for Microsoft SQL Server to automatically increment beyond that threshold, if and when the threshold is reached. Predicting Disk Space and RAM Requirements at Configuration Time The following information describes disk space and RAM usage in various configuration environment scenarios. Initial Application Installation Data 7.1 MB + 7.5% 7.7 MB + 7.8% Incremental Growth Events Derive "X" more templates or instances. Derive "X" more templates or instances. Auto-incremented size at reporting time. Auto-incremented size at reporting time MB +8.3% MB + 8.7% Summary Increment Range to 11% Disk space and RAM consumption are somewhat predictable for a fresh installation of Microsoft SQL Server, the ArchestrA Bootstrap, the Galaxy Repository, the IDE, and the SMC.

223 Assessing System Size and Performance 223 All disk space and RAM capacity in the following table are approximate: Component Disk Space RAM Microsoft SQL Server SP3 55 MB on disk 22 MB RAM.NET 1.0 Framework 36 MB on disk 0.6 MB RAM * ArchestrA Bootstrap (including the 19 MB on disk 7 MB RAM.NET 1.1 update) ArchestrA Galaxy Repository, IDE, and 32 MB on disk 2 MB RAM SMC Creating the empty Galaxy and running 70 MB on disk 63 MB RAM IDE Logs for SMC, starting up SMC. 3 MB on disk 7 MB RAM * Version 1.0 of ArchestrA installed.net 1.0 Framework; newer versions update to 1.1 Framework or later. Deployment of the Galaxy's Platform on the Galaxy Repository node, plus the AppEngine object and an Area object, occupies disk space and consumes RAM. All disk space and RAM capacity values in the following table are approximate: Task Disk Space RAM Create GR Platform 3 MB on disk 28 MB RAM Create GR state (small increment) (small increment) Create GR first Area (small increment) (small increment) Deploy GR Platform 16 MB on disk 31 MB RAM Deploy GR state (small increment) (small increment) Deploy GR first Area (small increment) 6 MB RAM Creating Simple Object Templates RAM utilization on the ArchestrA Galaxy Repository IDE node is negligibly affected by the creation of simple object templates. However, certain aggregated, hierarchical Application Objects will immediately consume RAM. Application Objects that contain multiple child objects (such as the AnalogDevice object, DiscreteDevice object, and FieldReference object) consume RAM in the IDE node upon creation of a containing template object.

224 224 Chapter 10 Creating Derived Templates Creating individual derived template objects from base template objects has negligible immediate effect upon disk space and RAM consumption. However, large numbers of derived template objects increase the Galaxy Repository size. The database occasionally auto-increments by a 7% to 11% growth factor, as opposed to incrementing when individual objects are created. You can estimate the expected disk space utilization for each type of derived template object by first determining a size factor for each. Then, multiply the size factor by the planned number of objects of that type. To determine the size factor, create 100 template objects of the particular type and observe the database size impact for the Galaxy Repository. To analyze the impact of this action, it is not sufficient for you to simply look at the disk size property for the disk drive that contains the Microsoft SQL Server database. A good approach for determining the incremental size of the Galaxy Repository database is to use Microsoft Query Analyzer and run the sp_spaceused stored procedure against the Galaxy Repository database. The GR database is visible with the name that you gave the Galaxy when you created it. The sp_spaceused stored procedure returns three columns: database_name, database_size, and unallocated space: The following table contains an example of calculating the increase in Galaxy Repository database size after creating or importing a specific number of object templates: Galaxy State Before addition of derived object templates After addition of 100 derived object templates of type XXX Database size increase by addition of 100 derived object templates of type XXX Calculation of approximate size factor for derived object template of type XXX Database Size Unallocated Space Actual Space Occupied MB 0.28 MB MB MB 0.36 MB MB MB MB / 100 = MB

225 Assessing System Size and Performance 225 The size factor for different derived object templates varies due to differing selections of UDA attributes and differing attribute extensions. Derived Object Templates and QuickScripts If you include a QuickScript as an extension of any derived object template, this will require additional Galaxy Repository database space. The following is an example of a calculation of a size factor for the inclusion of a QuickScript. As the QuickScript in any particular base derived template will be unique, the resulting size factor may need to be calculated for each case. Galaxy State Database Size Unallocated Space Actual Space Occupied Before addition of a QuickScript MB 0.36 MB MB After addition of a QuickScript function with 100 lines of code to a derived object template of type XXX MB 0.06 MB MB Database size increase for the QuickScript with 100 lines of code Creating Object Instances MB Creating instances of base and derived Application Objects (instantiation) has a negligible individual effect on the Galaxy Repository database size. However, large numbers of instances will occupy additional space. To determine the size factors for object instances, use the method described in Deploying Object Instances (following section). Instances that contain inherited QuickScripts will not use additional disk space in the database; however, the addition of QuickScripts to individual instances of objects will occupy additional disk space. Predicting Disk Space and RAM Requirements at Run-Time The following section contains guidelines for predicting run-time disk space and RAM requirements. Deploying Object Instances Deploying an object instance does not affect the size of the Galaxy Repository database. However, deployment impacts disk space and RAM use on the target Platform. Deploying object instances to an AppEngine impacts RAM usage. The initial deployment has largest impact on RAM, since deployment involves loading the associated run-time software on the Platform node (local or remote). Subsequent object instance deployments (based on common templates) use much less RAM.

226 226 Chapter 10 The following table describes disk space and RAM usage when creating and deploying an aggregated Application Object instance containing multiple child objects. The objects are deployed on the local node: Task Create master object containing 10 objects each with 500 UDAs (total of 5,000 UDAs) and each containing 100 lines of inherited QuickScript Deploy master object containing 10 objects each with 500 UDAs (total of 5,000 UDAs) and each containing 100 lines of inherited QuickScript Disk Space ~ 4.5 MB disk space ~ 17 MB disk space RAM ~ 7.7 MB RAM ~ 2.5 MB RAM Some RAM on the local (target) node is used by the IDE, the remaining RAM is used by the Platform and AppEngine. Deploying to an XP Platform In a production environment, AutomationObjects may be deployed to an AppEngine on the XP platform. Estimating disk space on XP is problematic because of the System Restore feature. System Restore provides protection from inadvertent deletion of required system files. The end result is similar to a Backup/Restore operation on a Server operating system: the user can restore the machine from a certain point in time. However, the System Restore feature maintains extra copies of files on the local machine's disk drive, and provides limited administrative options. File copies are made at a random times determined by the operating system. The deployment operation generates the System Restore operation, but may not include all necessary executable files. Default System Restore Disk Space settings are as follows: For drives greater than 4 GB, System Restore uses up to 12% of the disk space. For drives less than 4 GB, System Restore by default only uses up to 400 MB of disk space The data store size is not a reserved space on the disk and the maximum size (to the max values defined above) is limited at any time by the amount of free space available on disk. Therefore, if disk space use encroaches on the data store size, System Restore always yields its data store space to the system. For example, if the data store size is configured to 500 MB, of which 200 MB is already used, and the current free hard-disk space is only 150 MB, the effective size of the data store is 350 MB ( ), not 500 MB. Note that disk space usage can be adjusted at any time. Note System Restore is accessed via the System utility in Control Panel.

227 Assessing System Size and Performance 227 System Restore is enabled by default. DO NOT turn off the System Restore feature on an operational ArchestrA Platform computer. Instead, assess disk space usage using an isolated test computer on an isolated Galaxy where System Restore is disabled. Predicting System Performance This section contains specifications and data that can be used to assess and quantify system characteristics. The data is derived from various test case results and is intended to provide a loose template for general system performance predictions. Compare this data to existing system performance data, then factor in the different FactorySuite A2 System applications' guidelines to make the best decisions for your deployment/integration project. The key items used to assess FactorySuite A2 System performance are: Unit Application Definition: Defines the size of the system in terms of object types, I/O points, alarm attributes, change rates, etc. Hardware Specifications: Baseline computer specifications. Baseline Server CPU Values: Describes Server performance (CPU Usage %) with specific numbers of instances and I/O points. Performance Data: Describes the network of PCs and PLCs. The bulleted items are explained in the following sections. Unit Application Definition A Unit Application is a unit of measure used to describe the size of actual customer application scenarios. Each Unit Application contains a total of 500 objects according to object type and other characteristics. The Unit Application concept is useful because it can be used to quantify system elements. For example, "Application Topology A contains 2 Unit Applications running on each of PC1 and PC2 and 1 Unit Application running on PC2."

228 228 Chapter 10 The Unit Application is defined by the objects it contains (see the following table): I/O Change Rate Avg. Alrm. Rate Object Type Object Count I/O Pts. Alarm Attrs. Hist. Attrs. Monitor Rate Discrete Device /min 0.5 sec 10/hr Analog Reg. w/input /sec 0.5 sec 30/hr Analog Reg. w/output /min 1 sec 10/hr Calculation (synchronous /sec 1 sec 30/hr script) Calculation (asynchronous /min 1 sec 30/hr script) once/10 secs Areas/SubAreas 1/ I/O Networks I/O Devices A Unit Application alone does not specify performance: it is a measurement of scale (size), not of rate, and should be used with other data to extrapolate and predict system performance. Object Type describes the type of object Template, such as Discrete Device, that was built using the Application Object Toolkit. Object Count describes the number of object instances for each template. I/O Pts. describes the average number of configured I/O points per object. Alarms Attrs. describes the average number of configured alarms per object. History Attrs. describes the average number of configured history attributes per object. I/O Change Rate describes the average rate of process data value changes per object. For example, the average number of discrete device transitions for PV. Monitor Rate describes the average rate of monitoring for data value changes per object by the system. This should always be at least as fast as the expected I/O change rate per object. Avg. Alarm Rate describes the average rate of new alarms detected per object by the system. Note The state scan period is 500 msec for the Unit Application except when there are six or more Unit Applications on the state.

229 Assessing System Size and Performance 229 Hardware Specifications A computer with the following specifications was used in testing the FactorySuite A2 System products in order to determine the sizing and performance guidelines: Operating System Windows 2003 Server (+ all current Service Packs) CPU Speed 2.4 GHz Physical RAM 1-2 GB Free Disk Space 15 GB Network Throughput 100 Mbps AppEngine Scan Rate 1000 ms (1 second) Baseline Server CPU Values The following table summarizes average base CPU usage for an AutomationObject Server without clients. The data represents the CPU used by an AutomationObject Server in a steady state (with no active client connections). These numbers would increase based on other tasks executed in the server, such as script execution, active client connections, etc. Object Instances I/O Points CPU Usage (%) % % % In order to optimize the use of RAM and CPU, it is very important to define what the scripting requirements are and to plan ahead for how the scripts are implemented. In many cases, it may be more efficient to create global objects to execute scripts that update data in multiple objects, instead of running the same script in all objects. For recommendations on applied scripting techniques, see Chapter 5, "Working with Templates."

230 230 Chapter 10 System-Wide Performance Baselines Configuration environment performance parameters were also captured using the development node of each test scenario: AppEngine startup (boot) Galaxy Load for 500 objects Galaxy Dump for 500 objects Deployment of 500 objects 1 minute for each 1000 objects 103 sec 60 sec 39 sec* * Deployment time is measured after the first instance of the base template has been deployed, since this deploys the code modules. Communicating with Field Devices When implementing systems with a large number of I/O points, try to determine what the possible I/O throughput levels will be. The I/O points hosted by an AppEngine will be updated every time the associated scan group is read. Scan groups are set up on the DIObject used to connect to Data Access Servers. These scan groups are configured with an update interval value. I/O points that do not need to be updated quickly should be placed into slower scan groups. This will minimize the impact to the control networks due to I/O updates. Performance Data A FactorySuite A2 System enables a great degree of freedom when configuring and deploying objects. While it is not practical to test all possible configuration and implementation combinations, three representative system topologies are detailed. The loading parameter details for each of those representative systems are also described. To determine the performance guidelines, each test system configuration was measured against a standard of health. For testing purposes, a healthy system is defined as follows: Absence of scan overruns. Absence of communication timeouts. Absence of excessive page faults. Acceptable average CPU utilization.

231 Assessing System Size and Performance 231 Object - WinPlatform Common Topology Performance Notes Each of the topologies discussed in this guide includes an Engineering Station node. It is assumed for this example that the Galaxy Repository also be located on this node. However, the Galaxy Repository is not required to be running once the objects have been deployed. For example, the portable GR or the typical engineering station that needs to be re-imaged multiple times, making its availability intermittent. SQL Server can be shut down in these scenarios with minimal impact to the running system. Installing the GR on a dedicated node has the following benefits: It separates the engineering station(s) from the running system. It prevents bulk operations (for example, a Galaxy load, mass import, change propagation, etc.) performed on the Galaxy Repository from impacting the running system. If the Galaxy Repository were running on a node where an AppEngine hosting other objects is also running, and a bulk operation was performed, they would compete for CPU resources. The competition could potentially result in scan over-runs or missed scans on the AppEngine. Separating these components prevents unnecessary disruptions in the running application. Improving Communication with Remote Nodes The $WinPlatform object has a set of attributes associated with the Message Exchange (MX) protocol which allow fine tuning communication between galaxy components. When the network bandwidth is limited, the connection is intermittent, or the amount of objects is too large (thousand instances), it is recommended to adjust these parameters to obtain a better performance in deployment and communication. It is important to keep in mind that the values may be changed based on specific conditions of operation. The values shown here are intended as a starting point for fine tuning the system. The following table shows the default values and recommended values for the MX parameters. Default Value Recommended Value Comments Message time-out ms 300,000 ms Increase to avoid timeouts when deploying large number of instances NMX heartbeat period 2000 ms 2000 ms Consecutive number of missed NMX heartbeats allowed 3 4 (Automation Object Server) 4 (Galaxy Repository) 4 (Visualization node) Increase to avoid false failovers in large systems For details on the attributes in the WinPlatform object, please refer to the $WinPlatform object Help.

232 232 Chapter 10 Checkpointing Attributes Every AppEngine in a galaxy saves changes to values of specific attributes (checkpointed attributes) to disk at a pre-defined period of time. The more attributes defined as checkpointed by an AppEngine, the more data is written to disk. It is critical to set up this attribute to achieve the best performance for the system and the process. In the event of a re-start of an AppEngine or after a failover, the system will read the checkpoint file to update the attribute values and start from there. The default value in the CheckpointPeriod attribute in the AppEngine is set to 0 as a safe way to checkpoint attributes every scan if the user is not aware of the functionality. However it is highly recommended to set this parameter to a higher value so that you can optimize CPU utilization and maintain data integrity in the event of a failure in the AppEngine. Note For more details on Checkpointing, see "Checkpointing" on page 74. For information on checkpoint attributes, see "Tuning Redundant Engine Attributes" on page 87. Bulk Operations Considerations Observe the following considerations for bulk operations: Importing a large Galaxy with multiple levels of template containment may take a long time. Actual time is dependent on the size of the Galaxy and number of template containment associations that must be handled during the import process. For large numbers of Platforms and Engines residing on computers that are situated over slow network connections, it is not recommended to initiate a Cascade Deployment of the entire Galaxy. For such networks it is important to deploy the Platforms separately. Also, Platforms that have complex combinations of Areas and Objects or large numbers of Objects should be selected in smaller groups and deployed as groups. For better performance and scalability, increase the SQL Maximum Memory usage to be a larger portion of actual physical memory. In the Server Enterprise Manager, right-click on the SQL Server, select Properties. On the Memory tab, select "Dynamically configure SQL memory" and increase the Maximum Memory. Note Configuring Dynamic Memory allocation for SQL Server is most appropriate for a FactorySuite A2 System that is predicted to undergo significant changes and where disk space/memory use is difficult to estimate. In the case where disk space and memory use are known more precisely, see "RAM Allocation" on page 221.

233 Assessing System Size and Performance 233 Handling Multiple Engines It may be efficient in a system to distribute the load of Automation Object instances into multiple engines. It is a particular advantage when running the application in a multi-processor PC, as each engine running in its own single thread, will be distributed by the Operating System throughout the processors. In Industrial Application Server 2.0, a platform can host a maximum of 20 engines. The platform counts as one engine, leaving 19 available slots. However, it is not recommended to use more than 16 engines on a single platform. Using more than 16 engines on a platform may deteriorate system performance. To determine whether to place multiple Engines on a platform, analyze the Scheduler.ExecutionTimeAvg in the Object Viewer and strive to not to exceed over 30% - 40% of the scan cycle execute time. Also, if the speed you require cannot be accommodated with one engine, you may need to split engines. You may need multiple engines (1) when there are differing scan rates or scan overruns, (2) when there is high execution time and/or (3) when you need to bring data in faster. When you have sets of objects that do not require fast execution, you can group them on one engine. In a system in which you can group application objects based on scan rates, use a platform for each object group. Important! Be sure to monitor CPU usage when adding engines. Also, remember that with multiple engines you are moving Areas. If you have only one Area, you must create sub-areas. Best Practice To keep multiple engines with the same configuration from firing simultaneously, set their scan rates to prime numbers. For example, the scan rates of the various engines might be set at 997 ms, 1009 ms, and 1021 ms. Disable Hyper-Threading on computers that support this hardware function. Hyper-Threading gives a false impression of lowering processor load while actually increasing the load on the actual (rather than virtual) processor. Platforms that are routinely placed off scan may cause a certain amount of increased network traffic coming from other platforms if the other platforms have Application Objects still on scan that subscribe for data from Application Objects belonging to the off scan Platform. If the resulting increase in network traffic becomes excessive, consider placing the "subscriber" Application Objects off scan as well during the time that the particular platform is scheduled to be off scan.

234 234 Chapter 10 Single Node System Implementation Although intended for use in a distributed topology/distributed system environment, Industrial Application Server (version 2.1 and later) and FactorySuite A 2 components can be implemented effectively on a single node. Single Node configuration is supported on IAS 2.1 (and later), and InSQL 9.0 (and later). A new install of these two products (to a "clean" machine) is recommended. Upgrades of previous versions (IAS 2.0 or InSQL 8.0) when migrating to a single node configuration will cause problems. However, future version upgrades from IAS 2.1 and InSQL 9.0 on a single node are supported. Please contact Wonderware Technical Support for further assistance and details. Note In a Single Node implementation, performing bulk operations (Import/Export, Deploy, etc.) on the GR may impact the runtime system. Single Node System implementation differs from the "Standalone Workstation" topology, since all components/functions are combined on a single machine. The following components have been tested on a single node: Configuration Database (GR) Historian (IndustrialSQL Server 9.0 and later) Visualization (InTouch Software) Development (IDE, SMC) Analysis Client (ActiveFactory) Note For detailed information on topology component roles, see "Topology Component Distribution" on page 30. Integration testing was performed successfully (i.e., the components installed and ran correctly) on both Windows Server 2003 (recommended implementation) and XP Professional operating systems. Note Installation and implementation on a single XP Professional node is recommended ONLY for use within a lab or demonstration environment, or within the boundaries of the Application Specification defined in this section. Windows Server 2003 is the standard operating system for use in any production environment. The following information is derived from the test results and provides detailed information for installation and operation on a single machine. Hardware/Software System Requirements The following values represent minimum hardware size requirements:. Hardware Component Processor RAM Hard Disk Minimum p4, 2 GHz 1GB 10GB

235 Assessing System Size and Performance 235 The following operating systems, SQL Server editions, and auxiliary software were tested: Operating System Windows 2003 Server Windows XP Professional SP2 Antivirus software and other software such as Ad Aware should also be running on this machine Microsoft Office applications SQL Server SQL Server SP3a Standard Edition SQL Server 2000 SP3a Personal Edition The tests were performed on a single, standalone computer. Data was provided through different sources, either by direct connection or a network connection. Application Specification The following specification was implemented for single-node tests: 1000 I/O points with update rate 1 sec - make sure these I/O points are distributed among all different data types and are distributed between the DA Servers and legacy I/O Servers as well as be sure to use all three communication protocols (S/L, OPC and DDE). 50% floats, 25% bools, 10% strings, 15% integers. 10% changing I/O points items were updated every second. However, the server scanned for 1000 items per second 10% I/O points Historized - maintain the same ratio for various data types. (Maximum) 3 AppEngines - Approximately 70 objects per engine. (Maximum) 200 AppObjects - 5 I/O points-per-object. Alarm rate: 2 Alarms per second. System Components The single node includes the following components: Galaxy Repository IDE BootStrap InTouch Software HMI IndustrialSQL Server Historian ActiveFactory 9.0 DAS ABCIP ABTCP Legacy I/O Server DDE Server DASSIDirect

236 236 Chapter 10 The following data was gathered over a period of approximately 2.5 days from a system running Windows Server Performance on the XP Pro node was found to be similar enough to be considered redundant for this document: Galaxy Specification Component AppEngines 3 AutomationObjects 1100 (each with 5 I/O points) DAServer DASABCIP IOServer ABTCP DIObject DASDIDirect Historian InSQL Historian IDAS Tags 75 MDAS Tags from IAS 2108 (10% Historized) Page Fault Usage (Memory) 1.01 GB Network Utilization % Single-Node Process Performance Data CPU % PrivateBytes Avg. (Bytes) PrivateBytes Last (Bytes) Memory Usage (KBytes) Total aabootstrap aaengine aaengine aaengine aaengine aagr aahidassvc aahmanstsvc abtcp DASABCIP DASSIDirect lsass aatrend SQL Server

237 Assessing System Size and Performance 237 Large Distributed FactorySuite A 2 System Topology Distributed local systems include a peer-to-peer topology and offer the advantage of autonomy; that is, each node is self-contained and can run independently of its peers. Each node includes a visualization client and an AutomationObject Server. Supervisory Network Workstation Historian ( Data and Alarms ) Engineering Station Configuration Database SuiteVoyager Portal I/O Server Network Device (Switch or Router ) PLC Network Note For more details about this topology type, see the "Distributed Local Network" section in Chapter 2, "Identifying Topology Requirements."

238 238 Chapter 10 Large System Topology Elements The following elements and data is derived from extensive product testing in lab environments. The I/O data is based on simulated I/O. The following elements and data is derived from single Unit Applications (the Unit application table): Platforms - Peer-to-Peer AutomationObject 40 Server/Visualization node Platforms - Galaxy Repository Server 1 IndustrialSQL Server Historian Server Node 1 Object Instances per Galaxy 20,000 (40 nodes x 500 total object instances) Object Instances per Platform 509 (includes platform, areas, engines, etc.) Total I/O per Galaxy 34,224 (~ 36,000 or 900 Unit Application I/O points x 40) I/O Points per Server Platform 900 Inputs 300 changes/sec Outputs 10 changes/sec History stores 300 changes/sec Steady state new alarm arrival 3/sec Alarm bursts of limited duration 2000/sec Note Attribute tuning for Redundant AppEngines is described on "Tuning Redundant Engine Attributes" on page 87. In steady-state condition the system performed as described in the following table: Node CPU Memory (MB) Network 100 MB GR 5% % Historian 20% % AutomationObject Server/Visualization Node 60% (in 1.9 GHz PCs) 40-% (in 2.4 GHz PCs) 460 (Average) 0.7% (Windows 2003) 0.68% (Windows XP Pro)

239 Assessing System Size and Performance 239 Very Large Distributed FactorySuite A 2 System Topology This topology consists of dedicated Automation Object Servers and Visualization clients. The visualization clients are represented by nodes running platforms and InTouch Software as well as Terminal Services sessions. Note For performance data on SCADA systems on slow/intermittent networks, see Chapter 11, "Working in Wide-Area Networks and SCADA Systems." Specific Object attribute settings can be configured to make the object perform more efficiently. It is very important to know how to use those values as it may degrade the system performance if they are changed without a good understanding of their function and of how they relate to other attributes and conditions. Terminal Services Clients (Thin Client) Visualization (Data, Alarms, History) Dial-up 28.8k bps line Ethernet Terminal Server SuiteVoyager Portal AutomationObject Server Historian (Data and Alarms) Engineering Station Configuration Database SCADAlarm I/O Server Network Device (Switch or Router ) Supervisory Network Network Device (Switch or Router ) RTU Radio Modem Control Network RTU Radio Modem (RS-232) PLCs RS-485 Network RTU Radio Modem Level Transmitters The following elements and data is derived from the Unit application table that appears in a previous section.

240 240 Chapter 10 I/O Baselines Note This topology type was tested for integration purposes in a lab environment and uses simulated I/O for data generation. "Real" I/O results (from PLCs) are included in the following section as a subset of this test configuration. Platforms - Visualization Nodes 10 Platforms - AutomationObject 20 Servers Platforms - Galaxy Repository 1 Server IndustrialSQL Server Historian 5 Object Instances per Galaxy 50,000 Object Instances per Server 2,500 Platform I/O per Galaxy 1,100,000 I/O Points per Server Platform 55,000 I/O Change Rate 3% I/O points change every scan Alarm Rate 1% of I/O points per scan History Stores 7,000 changes/sec The following results table contains simulated and real I/O values: Results Table: Physical Memory Use (MB) Page File (PF Usage) Memory Use (MB) %CPU Average Primary Network line speed: 1 Gbps RMC Network line speed: 1Mbps %Network (RMC) Normal Engine N/A 0.01 (simulated I/O) Redundant Engine (simulated I/O) IT Platform (TSE) N/A 0.01 Load Sharing (simulated I/O) Redundant Engine (Real I/O) %Network (Primary) Note Attribute tuning for Redundant AppEngines is described on "Tuning Redundant Engine Attributes" on page 87.

241 Assessing System Size and Performance 241 Deploying Objects in a Large or Very Large System The ArchestrA system deploys objects in a "cascade" manner: that is, objects are deployed in hierarchical order. However, in the context of large- or very large systems, a cascade deployment, though reliable, may consume a large amount of system resources, or time, to complete the deploy operation. Note For details about different deployment scenarios, see the IDE Online Help (search "cascade" to filter results). In this context, a large system is defined as a system in a 20- to 50,000 I/O point range, and a very large system is one that has at least 50,000 I/O points. These values are approximate and must be considered along with other performance variables listed in the previous tables. When working in a large or very large systems, it is often more efficient to deploy object groups in a specific order, using the multi-select function in combination with, or instead of cascade deployment. Deploying objects in this scenario can save overall deployment time. To deploy in a large system For a large system, perform Cascade deployment from the Platform level. Make sure that Platforms hosting Primary Engines are deployed first, then Platforms hosting Backup Engines. This strategy avoids issues in loadbalancing environments. To deploy in a very large system When working in a very large system (high I/O, high numbers of Areas), use the multi-select (Ctrl + click) to deploy in the following sequence: 1. Galaxy Repository Platform 2. All other Platforms 3. Primary AppEngines 4. Backup AppEngines 5. Primary Engine for I/O (include redundant partner): Skip already deployed objects.

242 242 Chapter 10 Failover Performance Much testing has been completed to measure the performance of a system during a failover. Multiple variables have been considered to obtain representative data to reflect the average failover time, CPU and memory utilization in different configurations. Note that failover performance may vary depending on the number of I/O points referenced in the system, the amount of scripts per instance, task executed by scripts, historized data, alarms and checkpointed data. Script quantity and complexity will increase the failover time, as the system requires more time and resources to process them. This section presents two architectures with the corresponding application configuration and the results of the performance test. Note Attribute tuning for Redundant AppEngines is described on "Tuning Redundant Engine Attributes" on page 87. Dedicated Standby Configuration Visualization Visualization IT Alarm Provider IT Alarm Provider Supervisory Network AOS (PRIMARY) AE1 DI DAS RMC AE1 (Backup) AOS (BACKUP) Historian Alarm DB AlarmLogger Network Device (Switch or Router ) PLC Network The following table presents the hardware and software used in the architecture shown above. It also presents the configuration of the application tested.

243 Assessing System Size and Performance 243 Some of the variables in the table are dependent on the number of I/O points referred to in the application, so the value is shown as a percentage of the total I/O count for the particular scenario. Resources: Hardware Dell Precision 360, 1.0 GB RAM, Pentium 4 CPU 2.8 GHz Operating System Windows XP Pro SP2 for Redundant AppEngine nodes Configuration 1 Redundant AppEngine and 1 local DASABTCP DIObject DIObject ABTCPPLC Instances 1:8 ratio (instances:i/o points) I/O Change Rate 3% of I/O points changing every scan History 3% of I/O points historized every scan Alarms Total 10 alarms/sec Scripts per Instance 3 (1 On Scan, 2 execute every scan) AppEngine Scan Rate 1000 msec DIObject Scan Group 1000, 1200, 1500, 1700, 2600, 3300, 4400, and 4600 msec Modified Attributes Checkpoint period: Force failover timeout: Maximum time to maintain good quality after failure: Maximum time to discover partner: The following table presents the results of the test executed to measure the failover time as well as the CPU and Memory utilization. The Failover values are generated by two events: Network communication failure. Using the Redundancy.ForceFailoverCmd attribute in Object Viewer. Also note that another key component tracked in the test is the CPU consumed by the DIObject: I/O Counts Total Failover Time [sec] CPULoadAvg[%] Total Memory Usage [MB] Network Failure ForceFail overcmd Active Node Standby Node DASABTCP Active Node Standby Node Note During the transition of the engine from Standby to Active state, the CPU % value can spike to high levels.

244 244 Chapter 10 Load Shared with Remote I/O Data Source The analysis for the Load Shared configuration is very similar to the tests completed for the Dedicated Standby configuration. The following figure shows the one used in this validation: Visualization IT Alarm Provider Visualization IT Alarm Provider Supervisory Network AutomationObject Server 1 (Primary) RMC AE1 AppObjects RDI AE4' AutomationObject Server 2 (Backup) AE4 AppObjects RDI AE1' I/O Data Server 1 AE_2 DI 1 DAServer1 I/O Data Server 2 AE_3 DI 2 DAServer2 InSQL AlarmDB AlarmLogger Network Device (Switch or Router ) PLC Network The resources and configuration details are described in the following table: Resources: Hardware Operating System Configuration Dell Precision 360, 1.0 GB RAM, Pentium 4 CPU 2.8 GHz Windows XP Pro SP2 for Redundant AppEngine nodes 5 AppEngines and 2 RDIObjects with load sharing between redundancy pair platforms. DIObject ABTCPPLC DIObject Instances 1:8 ratio (instances: I/O points) I/O Change Rate 3% of I/O points changing every scan History 3% of I/O points historized every scan Alarms Total 10 alarms Scripts per Instance 3 (1 On Scan, 2 execute every scan) AppEngine Scan Rate 1000, 1100, 1200, 1300, and 1400 msec DIObject Scan Group 1000, 1200, 1500, 1700, 2600, 3300, 4400, and 4600 msec Modified Attributes Checkpoint period: Force failover timeout: Maximum time to maintain good quality after failure:

245 Assessing System Size and Performance 245 The results shown in the table below present the Failover time, CPU utilization and Memory Usage in different scenarios. This table also contains the CPU load on the node that hosts the I/O Servers. I/O Counts Total Failover Time [sec] CPULoadAvg[%] Total Memory Usage [MB] Network Failure ForceFail overcmd Active Node (postfailover) Standby Node I/O Server Nodes 1, 2 Active Node Standby Node , , , , , , Note During the transition of the engine from Standby to Active state, the CPU values spike at high levels. After failover, it will be necessary to restore the system to the original (loadsharing) configuration. The following script example would be used on both nodes and configured as While True with a trigger period of 10 minutes: if me.redundancy.status == "Active" and me.redundancy.partnerstatus == "standby - ready" THEN me.redundancy.forcefailovercmd = true; Endif; DIObject Performance Notes Each DAGroup (Scan Group, Block Read, Block Write) has a maximum capacity of 5000 items. For optimal performance, the group should not have more than 4000 items. Note that for each DAGroup added, an additional connection to the server is created. This extra connection increases the memory requirement on the server. If a decision needs to be made between either increasing the number of DAGroups or increasing the number of items in each DAGroup, the recommendation is to put more items in each DAGroup. As each DAServer's performance is subject to the requirements of the connecting devices and the protocols being used, it is also recommended to monitor the DAServer performance levels and adjust the maximum number of items that subscribe to the DAServer. For optimal performance, the CPU consumed by DAServers on each machine should be no more than 55% when items are constantly subscribed.

246 246 Chapter 10 OPC Client Performance This section describes the relationship between CPU usage and Scan Groups, versus Object usage. Industrial Application Server (IAS) was configured with OPCClient Objects accessing a DAServer on a remote node. The DAServer was configured to retrieve changing data from a PLC via an Ethernet connection. The items with the OPC Client Scan Groups were accessed via Object Viewer. Note The test results described in this section do not take into consideration implementation of Object Scripts, which will affect the execution of the AppEngine; nor do the results account for limitations in the number of items which can be accessed through a single object. The performance test was conducted with the following basic topology: DELL Precision Ghz 512MB RAM Windows Server 2003 sp 1 IAS 2.0 sp 1 DELL Precision Ghz 1024MB RAM Windows Server 2003 sp 1 DASABCIP 3.0 sp 1 Allen Bradley ControLogix Model 5555 The test was conducted using the following strategies: 1. Establish "Base Line" CPU consumption. A. An OPC Client Object with 2,500 items in 5 Scan Groups was measured. B. Items were then increased to 5,000. C. Items were then increased to 10, Measure CPU consumption when increased scan groups are used. A. An OPC Client Object with 10,000 items in 5 Scan Groups was measured. B. The 5 Scan Groups were evenly split into 10 Scan Groups. C. The 10 Scan Groups were evenly split into 20 Scan Groups. 3. Measure CPU consumption when increased OPC Client Objects are used. A. 5 OPC Clients with varied number of items, totaling 10,000, were deployed. B. The 5 Objects were split into 10 objects with item total remaining at 10,000. C. The 10 Objects were split into 20 objects with item total remaining at 10,000.

247 Assessing System Size and Performance 247 After the Objects were deployed, the system was "stabilized" for 5 minutes to attain CPU usage. The following results are represented in percentage of total system utilization: Test Strategy Reference Objects Scan Groups per Object Items CPU % 1A B C A B C A B C OPC Client Performance CPU % Items Scan Groups Objects Item Count Multiple Scan Groups Multiple Objects The use of multiple Scan Groups appears to have more impact on system performance than does multiple items, although under these test conditions, each are negligible.

248 248 Chapter 10

249 Working in Wide-Area Networks and SCADA Systems 249 Chapter 11 Working in Wide-Area Networks and SCADA Systems This chapter discusses application of FactorySuite A2 products in Wide-Area Network (WAN) and Supervisory Control and Data Acquisition (SCADA) systems environments. The WAN network environment exhibits the following characteristics: Low bandwidth. High latency. Intermittent communication. Note This chapter contains information and terms specific to the SCADA Industry. Contents Wide-Area Networks Overview Network and Operating System Configuration Security Application Configuration Overview Platform and Engine Tuning Diagnostics SCADA Benchmarks

250 250 Chapter 11 Wide-Area Networks Overview Wide-Area Networks (WANs) are comprised of computers located across large geographical distances. Communication between the computers is typically handled by modems, T1 lines, or satellite links. Data transmitted in this environment must travel through a large number of network components (routers, satellites, modems). By doing so, latency (delay from when the data was sent to when it was received) is increased. Further, the underlying technologies used for communication are limited to low bandwidth. As a result, these "distributed" networks often experience delays or breaks in communication due to relatively high amounts of network traffic, or interference by external conditions such as severe weather. WANs are used in industries such as Water and Waste Control, Telecommunications, Natural Gas production, and Oil production/distribution, where they are implemented as part of a SCADA system. The SCADA system is usually a central computer that communicates over the WAN to remote PLCs or RTUs. Note In this context, a Remote Terminal Unit (RTU) is defined as an industrial data collection device typically located at a remote location, which communicates data to a host system by using telemetry (such as radio, dial-up telephone, or leased lines). A SCADA system gathers real-time data, transfers the data to a central site, performs the necessary analysis and control, and displays the information visually in an appropriately organized fashion. SCADA topologies can easily be expanded to handle additional remote sites and I/O points (see Distributed SCADA Topologies later in this chapter). The SCADA system collects and records data events and alarms. A SCADA host performs centralized alarm management, data trending, and operator display and control. Current status and commands are handled by remote controllers (RTUs and PLCs). SCADA systems employ RTU or PLC protocols including Modbus, AB-DF1, and DNP3.0. SCADA communications can use a range of wired (lease line, dialup line, fiber, ADSL, cable) and wireless media (licensed radio, spread spectrum, cellular, CDPD, satellite). I/O servers and DAServers collect data from remote units, then send this data to the Industrial Application Server using OPC or SuiteLink protocols.

251 Working in Wide-Area Networks and SCADA Systems 251 Network Terminology When metric prefixes (k for kilo, M for Mega) are used in a network context, they retain their original definitions. That is, k = 1,000 and M = 1,000,000. This usage differs from disk-storage terminology, where KB = 1024 Bytes and MB = 1, 048,576. The following table summarizes the conventions used in this chapter: k 1,000 M 1,000,000 B Byte b bit bps bits-per-second Bps Bytes-per-second Network and Operating System Configuration The following information refers to both network component configuration and the operating system configuration necessary to function successfully. Some information is included for contextual purposes only. Minimum Bandwidth Requirements Subnets The slowest network connection speed supported with Industrial Application Server 2.1 for platform, history, and alarm communications is 128 kbps of dedicated bandwidth. This is totally independent of communications between OPC/IO/DAServer and field devices (RTUs, etc.), which is typically done over a different device network using RTU and/or other industrial protocols, often at slower data rates (i.e.: 56 kbps and lower). Check ping times for remote nodes and consider improving the available bandwidth or reducing I/O polling frequencies for those nodes that exhibit very slow ping times. For information about using Ping for checking and diagnostics, see "Diagnostics" on page 266. Set up subnets and sub-areas in the IP network. Most SCADA systems use routers and switches to isolate traffic within a particular site so as not to burden the network. Be sure routers are configured to isolate and route information correctly.

252 252 Chapter 11 DCOM When assessing and setting up the network, be careful in setting blocked ports. Some DCOM ports need to be open to communicate with OPC. Leave open the ports that interact between FactorySuite components. For a list of ports used by FactorySuite components, refer to "Process Control Network Firewall Ports" on page 203. Domain Controller The Domain Controller is a Windows server computer that stores user account information, authenticates users, and enforces security policy for a Windows domain. Domain controllers detect changes to user accounts and synchronize changes made in Directory Server user entries. Distributed SCADA networks typically employ multiple Domain Controllers at strategic network locations. The Domain Controller node includes the DNS service and Time Synchronization to manage network communication requests. Domain Name Server (DNS) An Internet service that translates domain names and host names into IP addresses. Time Synchronization The Windows 2000 environment uses W32Time services to synchronize time settings across a network. For a detailed description of the Windows Time service, how it operates on a Windows 2000 network, and configuration details, see wintimeserv.asp. The end result is that all computers within the network running W32Time reliably synchronize to a common time. Best Practice Implement Universal Time Synchronization (UTS) at each site. Doing so provides absolute certainty that data is properly time-stamped and forwarded to the historian under all circumstances. Current technology uses GPS or radio broadcast software along with dedicated hardware devices that may linked to one or more computers at the site using serial ports, Ethernet or USB. The following considerations apply when implementing UTS: If time master provider is not in same geographical area, there is a risk of losing a connection to the time server through time "drift." In other words, nodes in the same geographical area should have access to a master in the same area, or use a GPS.

253 Working in Wide-Area Networks and SCADA Systems 253 Synchronize all Domain Controllers with a common time provider. The Windows service uses time stamp as a part of the Kerberos security implementation. Kerberos is a system that provides a central authentication mechanism for a variety of client/server applications, using passwords, secret keys, and time-sensitivity. If the time between clients/domain Controllers, or between Domain Controllers (in other geographical areas) drifts, the operating systems may fail. GPS Time Provider software is commonly available to ensure reliable and standardized time synchronization.

254 254 Chapter 11 Remote Access Services (RAS) The following information focuses on Remote Access Server node topologies and is specific to the dial-up connection mode. The following figure represents a possible SCADA topology that utilizes modem communications. Note that the Domain Controller and Router reside on dedicated nodes: Visualization Node/Alarms Subnet 1/Control Room Domain Controller/DNS Server Historian ( Data and Alarms ) Engineering Station Configuration Database Supervisory Network 10/100Mbps Network Device (Switch or Router ) RAS Server Modem (56kbps) Subnet Kbps Modem (56kbps) RAS Client (also performs routing ) 10/100Mbps Network Device (Switch or Router ) Control Network Subnet 3/Remote Site Visualization Node Visualization Node PLC PLC Overview Remote Access Server (RAS) is often used to connect remote computers with a central computer. The use of telephone modem technology is commonly used when the application requires communication over very long distances and does not require a robust connection, high throughput, and low latency. In addition, using modems allows the user to configure the connection from the RAS client to the RAS server as a call-back, dial-on-demand, and hang-up-onidle or persist-connection. Note Even though modems have low nominal throughput, they can achieve high effective throughput by using software and hardware compression.

255 Working in Wide-Area Networks and SCADA Systems 255 Terminal Services Terminal Services (TS) is optimized to use minimal network bandwidth. As such, TS works fairly well across modems. When managing a remote AppServer node using the IDE, connect with a dedicated Terminal Services node to manage the connection with the remote node. Ensure that the remote can be pinged successfully. To do so, the DNS server must be able to resolve all remote Node Names. Industrial Application Server IDE does not support slow network connection between the GR and the IDE. A Terminal Services session (from the remote client) is the preferred method of configuring the Galaxy. InTouch HMI When NAD is used in a Terminal Services environment on a Windows 2003 machine, a share must be created on the Master application even if the Master is on the Terminal Server Node. InTouch for Terminal Services Environment (TSE) may be installed on a central computer and client sessions may be run at remote sites. Please refer to the InTouch TSE Deployment Guide for more information. IndustrialSQL Server Historian No special configuration is required in this context.

256 256 Chapter 11 Security This section contains security information specific to a SCADA environment. For general security-related information, see Chapter 7, "Architecting Security." Domain-Level Security The ArchestrA Network account must be configured on the Domain Controller and used by all local and remote component installations. In order to maintain a central point of security administration, the following configurations are recommended: For Industrial Application Server, configure OS Group-based security. For InTouch Software, configure ArchestrA security from WindowMaker. These settings facilitate a centrally-administered security model within the distributed Microsoft domain. Note The OS Group Security mode has potential network-related implications with SCADA systems. See "OS Group Based Security Mode Notes" on page 205. Distributed SCADA systems will likely use more than one Domain Controller. Such distributed topologies join computer nodes at different sites to different Domain Controllers; the operators, engineers and technicians log into those Domains. For systems with remote sites that are prone to long disconnected periods (from the central network), it is important to distribute additional DNS servers and Backup Domain Controllers at strategic points in the network. A single ArchestrA network account is accessible from any domain. A Galaxy can span multiple domains, but a single ArchestrA network account must be used for all nodes. This account can be a local account on each node, each account having the identical name and password. Domain control and authenticated token cache expiration time are features of Microsoft security. Before changing domain parameters, refer to Microsoft documentation. It is critical to properly configure the DNS settings for the NIC adapter to ensure that multiple Domains are visible to the computer. This configuration is performed when installing the Bootstrap on each node. Microsoft Security with Active Directory and DNS supports invoking such "cross-domain" accounts at installation time. Tune expiration times relating to domain control and security. For example, in a scenario where Industrial Application Server security is enabled as OS User or OS Group for the Galaxy and the node is temporarily disconnected from a domain controller, logins to SMC, Object Viewer, and InTouch Software still succeed; but for a limited time.

257 Working in Wide-Area Networks and SCADA Systems 257 If a domain is out of communication for a period of time, tokens are locally cached until the configured timeout. If the operating system's default expiration time is too short for your operation, modify/extend the expiration timeout setting for cache security. Industrial Application Server Galaxy security (run-time) is configured via the Security dialogue of the IDE. Users/Groups are assigned, states are created and mapped to Galaxy privileges, and individual Application Objects are allocated to Security Groups. As long as their membership is then authenticated against Galaxy authorized groups, they will have access to the capabilities of the system. All Industrial Application Server installations must use a common Domain, User Name and Password for authentication, even for the case in which there are multiple Domain Controllers in the system. The same-named domain account must exist as a member of the local administrator's group on each node; i.e. it must be one Domain, one user name and its associated password. This ensures a contiguous Galaxy. Ensure the Login Time is at its default value of 1000 ms, and not 0 (disables the login). Note For IAS 2.0 and earlier, 0 is the default value. This setting limits the role-validation part of the login to 1 second and improves login time on an application in a SCADA system using "OS Group based security." Role-validation on a large system might otherwise take many seconds. To change the default login time 1. Launch the IDE on the GR node. 2. Select Galaxy > Configure > Security from the main menu. 3. Change the default login time to 1000 ms. InTouch HMI Use the ArchestrA security model selection within InTouch WindowMaker. IndustrialSQL Server Historian When the Historizing data, the ArchestrA Network account used in IAS must also exist on the IndustrialSQL Server Historian node as a Local Administrator account.

258 258 Chapter 11 Workgroup-Level Security Configure the following security permissions on each node as applicable: Industrial Application Server All IAS installations must use an identical local account. The same-named local account must exist on each node as a member of the local Administrator's group on each node. This ensures a contiguous Galaxy. InTouch HMI Use the ArchestrA security model selection within InTouch WindowMaker. IndustrialSQL Server Historian When the Historizing data, the ArchestrA Network account used in IAS must also exist on the IndustrialSQL Server Historian node as a Local Administrator account. Application Configuration Overview The following material includes system-wide recommendations in a FactorySuite A 2 System environment. Acquire and Store Timestamps for Event Data For RTU protocols where data timestamps may be retrieved from the remote site, it is necessary that a DAServer or I/O Server acquire this timestamp and make it available as a parameter of the data. Given the data's value and its timestamp, it is possible to transfer the data's value and timestamp into the historical database or process the data with event analysis algorithms. Such data transfer and processing operations require the development of specific Application Server objects designed for this task. Acquire and Store RTU Event Information In cases where RTU protocols and event information may be retrieved, particularly as structured blocks with point ID, value, timestamp, and description, a DAServer or I/O Server must acquire the structured information and make it available for processing. Typically this requires special programming for the server that transfers the data to a database. In particular the data may be transferred directly into the IndustrialSQL Server Historian node.

259 Working in Wide-Area Networks and SCADA Systems 259 Disaster Recovery It is important to establish a site, physically separated from the central one, that has replication capability. Doing so ensures the integrity of an operational system where the central site is at risk from fire, tornado, hurricane or other catastrophe. The replication capability includes having duplicated hardware, and requires that software configuration and key state information is periodically propagated from the central site to the recovery site. Each disaster recovery scenario will be unique, thus it is important to consult with system integration experts regarding the design of communications equipment, hardware and the configuration of the software. Industrial Application Server (Distributed IDE) Install the IDE on a Windows Server 2003 Terminal Services node. Remote computers log on as a Remote Terminal Service session. Important! Security accounts for remote computers on which the IDE is installed must be given Administrator privileges at the central Terminal Services node. Do not develop from a remote IDE that accesses the Galaxy Repository over a slow network connection. Initiate a Remote Desktop session and run the IDE on the GR node, or initiate a Terminal Services session. Caution! Installing IDEs at remote sites and/or remote computers consumes significant network bandwidth. Distributed SCADA Topologies The figure on the following page shows 3 common topologies found in a distributed SCADA environment. The topologies represent test metrics included in the SCADA Benchmarks section of this chapter. Each remote area contains 3 nodes: 1 Visualization node and 2 AOS nodes. The AOS nodes include Visualization capabilities. All AOS nodes connect to PLCs and generate alarms, send data changes to a Historian, and update subscriptions. Domain controllers and security are used to demonstrate cross-domain communication. Galaxy and applications use OS Group Base security:

260 WAN 260 Chapter 11 Guest Node Central Visualization Control Room Historian IAS Galaxy Repository (Data and Alarms) Engineering Station (IAS Multi IDE, Visualization Master ND) Terminal Services VPN Corporate 10/100Mbps Gateway Router Cisco Router 9600bps-4Mbps WAN Cisco Router HUB\Switch 100Kbps Bandwidth Controller 10/100Mbps HUB\Switch Radio Tower Radio Tower Area3 9600bps-100Mbps Domain Controller 10/100Mbps Cisco Router Site HUB\Switch Site Domain Controller Modem (56kbps) 33.6Kbps Modem (56kbps) 33.6Kbps 9600bps-4Mbps Visualization Primary AOS Node + Visualization Redundant Message Channel Area1 Modem (56kbps) Modem (56kbps) Cisco Router Backup AOS Node + Visualization 10/100Mbps 10/100Mbps HU\Switch RAS Client AOS Node + Visualization HUB\Switch Area2 Visualization RAS Client AOS Node + Visualization Site PLC3 Site 10/100Mbps Site HUB\Switch Visualization AOS Node + Visualization Site AOS Node + Visualization PLC1 PLC2 Area 1 Communication Uses a 56kbps modem connection through a domain controller. The modem is not modified because of excellent compression capabilities. Area 2 Communication Radio modem link to 128kbps full duplex. The Cisco router clock rate is set to 125,000kbps Area 3 Communication Bandwidth-controller set to 16,000bps. The information on the following pages references the above topology. ApplicationObject Deployment Do not initiate a Cascade Deployment of the entire Galaxy when large numbers of Platforms and Engines reside on remote nodes over a distributed network. Rather, deploy the Platforms separately. Separate Platform deployment prevents overloading the network.

261 Working in Wide-Area Networks and SCADA Systems 261 Platforms that have complex combinations of Areas and Objects or large numbers of Objects should be selected in smaller groups and deployed as groups. Perform the initial deployment at the central control location, then ferry the node to the remote site. Platform and Engine Tuning Decreasing the engine scan rate decreases the event data that must be transmitted. Note For more information on tuning for redundancy in large and very large systems, see "Tuning Redundant Engine Attributes" on page 87. Tuning the Historian Primitive/MDAS (in Platforms and Engines) Set deadbands for parameters of data to historize; increasing the deadband decreases the network traffic. Do not enable the Historian component in WinPlatforms and AppEngines unless they will actually be hosting Historized objects. Do not enable the Historian feature (a check box in the Objects IDE Editor form) in the highest level template for any object because this forces historization of every instance. Selectively apply the Historian feature to some templates and to specific instances of objects. Modify the Historian tuning constants which are attributes of the Engine component found in the WinPlatform and AppEngine objects. Note The following attributes' default values are designed for a nonintermittent network environment and are especially important in a widelydistributed, redundant system. The attributes are listed with the default values. Engine.Historian.StoreForwardMinDuration: 0 s (seconds); Engine.Historian.ForwardingChunkSize: 1024 Bytes; Engine.Historian.ForwardingDelay: 250 ms (milliseconds). Modify the default values after careful observation of network bandwidth utilization: Increasing the StoreForwardMinDuration value forces the machine to function in "Store" mode for a longer time, and prevents the machine from trying to re-connect to the Historian prematurely. The longer duration allows time for the network problem to resolve itself. Decreasing the chunk size should accommodate slower network connections.

262 262 Chapter 11 Increasing the Forwarding Delay value should ensure data packets arrive and are stored before the following packet arrives. Note The previous 3 Historian-tuning attributes are available in IAS 2.0 and later. They are accessible using the AppEngine and Platform Editors (Engine tab). For detailed attribute information, see the AppEngine 'General Configuration' help file. For the occasions that communications with the Industrial SQL Server Historian are interrupted, local storage and recovery of historical data is provided. It is important to configure the Historization parameters of the Engine Object using the IDE to accommodate the number of packets that will be transmitted over the network when data is being restored. Be sure enough disk space is on the local node to temporarily store data until it can be transferred to the historian. Note For detailed information on changing the default Platform Start Up and Shut Down settings, see "Tuning Recommendations for Redundancy in Large Systems" on page 86. Alarms When the (default) InTouch Alarm Provider option box (in the Platform Editor) is checked, and the Area text is blank when you configure the Platform Object, a subscription is initiated to all Alarms throughout the Galaxy, regardless of the originating node. It is important to configure specific Area names for the Platform Alarm subscriptions in order to reduce the number of alarms this platform subscribes to. Do not leave the text entry field blank. Specifying Area names limits the alarm-related network traffic to the areas specified. Note Alarms from sub-areas (of those specified) create subscriptions because of the hierarchical design of the Alarm subsystem. Be sure that parent alarm areas are on the same node as their sub-areas. Alarm history is stored in an MSSQL Database. The default name for the database is AlarmDB which may be given a different name (using the configuration utility launched from the WWAlarmDBLogger application). WWAlarmDBLogger WWAlarmDBLogger is installed from the InTouch CD-ROM. It is a client application that subscribes to Alarm messages in the same fashion as the InTouch Alarm Clients do, including one or more Query expressions. The WWAlarmDBLogger application delivers alarm message content to the AlarmDB (or otherwise named) database using standard MSSQL network technology. It receives alarm messages from subscribed Areas via the InTouch Distributed Alarm protocol, which is verbose.

263 Working in Wide-Area Networks and SCADA Systems 263 For remote computers that connect to a central supervisory system over a slow network connection, the traditional deployment of Alarm components will result in slow response times over that connection and can interfere with delivery of live data. The recommended topology for slow network connections is to have individual MSSQL Alarm history databases located at the remote sites. This deployment ensures that all Distributed Alarm protocol messages are confined to the remote site's LAN. All database transactions posting Alarm log messages to the AlarmDB (or otherwise named) database are likewise confined to the LAN. Microsoft MSSQL DTS (Data Transformation Services) technology may be used to consolidate AlarmDB messages to a central database periodically for central analysis and reporting. Note For information on implementing Alarms, see "Determining the Alarm Topology" on page 215. Inter-Node Communications The following section considers platform communication when deployed across a widely-distributed and/or intermittent network (SCADA). A brief summary is included for context and is not intended as a recommendation, but as a "pointer" for the developer to begin tuning the communications to accommodate the needs, and mitigate the effects, of a SCADA system. The information assumes multiple platforms are deployed on multiple nodes in a SCADA topology. Communication Summary Communication between distributed platforms occurs at two levels: Heartbeats and messages (data change requests and replies, subscriptions, status updates/replies, etc.). Messages are handled by Message Exchange (MX) services. IAS is designed to monitor heartbeats and messages (sends/receives) on a regular, configurable basis. Several attributes can be used to monitor and tune the system to avoid problems in a SCADA environment; for example, heartbeats missed because of an intermittent network may cause all subscriptions to be dropped and re-initiated, saturating the network and preventing successful reconnection with remote nodes. The actual settings depend on the particular network environment. Tune the following attributes when implementing Redundant Platforms/Engines within a SCADA environment:

264 264 Chapter 11 NmxSvc Attributes Primitive Default Value NMXMsgMxTimeout WinPlatform 30,000 ms (30 seconds) NetNMXHeartbeatPeriod WinPlatform 2000 ms (2 seconds) These attributes can be set to balance correct and timely error notification with a stable system performance. For example, the DataNotifyFailureConsecMax value of 0 means that the system will begin tearing down subscriptions (and rebuilding them) if a Data Change Notification failure occurs at any time. Initiating this action means that the network is then flooded with subscription messages both when tearing them down and rebuilding them. This action may not be realistic in an environment in certain connections are sporadically intermittent. Using NetNMXHeartbeatsMissedConsecMax and NetNMXHeartbeatPeriod together provides the total time elapsed since the last heartbeat before the connection is declared broken. The formula is: (NetMNXHeartbeatsMissedConsecMax + 1) * NetNMXHeartbeatPeriod Remarks Can set at config-time and run-time if Platform is Off Scan. Specifies how long Engine waits for response from another Engine before declaring timeout. Can set at config-time and run-time. Specifies how frequently the NmxSvc sends heartbeats to remote Nmx services connected to it. NetNMXHeartbeatsMissedConsecMax WinPlatform 3 Can set at config-time and run-time. Specifies how many heartbeats are allowed to be missed before remote NmxSvc declares the connection broken. DataNotifyFailureConsecMax Engine 0 Determines the number consecutive Data Change Notification failures (with MX_E_PlatformCommunicationError or MX_E_RequestTimedOut) that will be allowed before the subscription is torn down by the publisher engine. Setting the values to smaller numbers should discover broken connections faster, but may also provide "false" broken connections because the Nmxsvc doesn t get enough CPU time to process incoming messages. Note These attributes do not directly affect failover. They specify when Message Exchange will declare communication errors. For information on Heartbeat settings within a locally-distributed environment, see "Tuning Redundant Engine Attributes" on page 87. Note that recovery time on a Distributed Network or from an outside disaster is longer on a redundant system.

265 Working in Wide-Area Networks and SCADA Systems 265 Note The redundant pair must be at the same physical location; they cannot be geographically separate. Redundancy for AutomationObject Server Engines may be applied as needed at remote sites. The Primary and Backup nodes must include individual NICs for their RMC channels and must use a simple crossover cable between them. The only impact upon network traffic will be some amount of additional packets during deployment from the central GR node to both the Primary and Backup nodes. Load Balancing Load balancing is relevant only in the central supervisory setting. This is because "load balancing" implies moving traffic to another CPU at the same location (SCADA systems have physically distributed architecture). In a central location, use a cluster of Application servers to distribute processing activities. Distributing InTouch HMI Nodes InTouch Software NAD (Network Application Development) can be used to design and configure systems, and to maintain graphical interfaces in a physically distributed system. The server maintains a master copy and clients maintain a copy of the master, so that if the master is unavailable, the client keeps working. Note that remotely notifying client applications of InTouch Software over a slow network is limited by the number and size of changes that may be effectively transmitted within a reasonable amount of time. Minimize Bandwidth Consumption on Initial Startup The InTouch Software NAD Master and Client nodes should be configured to minimize bandwidth consumption on initial start-up. Tech Note 380, InTouch HMI NAD and Slow Networks provides detailed steps for reducing startup time and network-bandwidth usage and describes: The NAD initial startup copy process and overview of the workaround. Detailed instructions for how to prevent a NAD client from copying the full application on initial startup. Other helpful NAD documentation references. Create a NAD Proxy Tech Note 390, InTouch NAD and Slow Networks outlines how to reduce network utilization in a NAD environment by configuring an existing InTouch Software NAD-Client to behave as a NAD-Proxy. The NAD-Proxy serves as a NAD-Client that accepts the application changes from the NAD-Master and then notifies the NAD-Clients on its local network of the application changes.

266 266 Chapter 11 NAD Do not include SmartSymbols in the InTouch Software NAD source application for distribution to HMI nodes over a slow connection (A change to any Smart Symbol causes recompiling of every window in the application and subsequent re-deployment of all windows). Instead, develop a master application using Smart Symbols and import only the modified windows and any modified scripts to the NAD source application. Configure the NAD client's poll intervals to avoid using network bandwidth. Alarms Instead of applying a single global query, configure displays to dynamically query different provider nodes. Alarms query an area directly using SuiteLink (and not MX) by specifying the node name (\\NODENAME\Galaxy!Area). WW Alarm DB Logger should log only to a local database or over a fast network. Allocate alarm groups between different stations and adjust visibility for appropriate areas. Some alarm groups may be at physically different sites. Select alarms that need wide-area visibility to minimize network traffic. Using IndustrialSQL Server Historian MDAS Time Synchronization MDAS may fail to forward some live data (over a Distributed SCADA network) when it recovers from a long Store Forward period. The data loss is caused by the Engine host node and the Historian node drifting out of time scope while the Engine is disconnected from the network. If the times are in sync when the engine reconnects, no data loss occurs. Diagnostics The following information is applicable within the SCADA environment: Ping Ping is a basic command that helps you check out the basics of your network. When pinging another machine, a sequence of special ICMP (Internet Control Message Protocol) Echo Request packets are sent. The receiving machine responds with an "echo reply." The Ping program reports a number of items including: the number of milliseconds it took to get a reply to each Echo Request packet, the maximum, minimum and average round trip times, the number of dropped packets and a TTL (Time To Live) value.

267 Working in Wide-Area Networks and SCADA Systems 267 The average round trip time provides an indication of the speed of your network. In general, it's best if round-trip times are under 200 milliseconds. The maximum and minimum round-trip times give you an idea of the variance ('jitter'). When large variance is present, you may experience poor response in communications. The number of dropped packets may be an indication of network problems. The TTL value helps you find out how many routers (or "hops") the packet goes through in order to get to its destination. Every packet sent has a TTL field set to an initial number (for example 128). As the packet traverses the network, the TTL field is decremented by one, by each router. If the TTL field in successive pings is different, it could indicate that the reply packets are traveling through different routes. Tracert Tracert traces the path followed by a packet from one machine to another. The results of this command also provide the IP address of each router the information goes through and how long it took on each hop. Reviewing the time between hops enables identification of slow or heavy traffic segments: If tracert is unsuccessful, you can use the command output to help determine at which intermediate router forwarding failed or was slowed. Looking for hops that have excessive times or dropped packets in the report from a tracert command can find potential trouble spots between two machines. Time Synchronization When the network cable is reconnected, the system event viewer may contain a message that the time provider NtpClient is currently receiving valid time data. This message does NOT mean the computer clock time sync happens. It means the internal clock is adjusted and will act as described in the bullets above. In other words, this message is sent every time the computer is reconnected, but only in certain cases is the actual computer clock also updated to the current Server time. In other cases, only the internal clock is adjusted and the computer time is gradually synced with Server time according to the algorithm.

268 268 Chapter 11 SCADA Benchmarks The following information is derived from Wonderware QA testing. MX Subscriptions Network Utilization MX Subscription change rate [points/sec] Traffic [kbps] Increase [Factor] 0 [heartbeat traffic] Note Tests performed with subscription to a 4-byte integer.

269 Working in Wide-Area Networks and SCADA Systems 269 Alarm Network Utilization MX Subscription change rate [points/sec] Traffic [kbps] Increase [Factor] 0 [heartbeat traffic]

270 270 Chapter 11 History Network Utilization History change rate [points/sec] Traffic [kbps] Increase [Factor] 0 [MDAS heartbeat] Summary Network Utilization Subsystem Change Rate Traffic MX Subscription 100 [point/sec] 11.7 kbps History 100 [point/sec] 21.1 kbps Alarms 100 [point/sec] 26.1 kbps Note Tests performed with subscription to a 4-byte integer. Proportion of bandwidth used by MX, History, and Alarm Traffic (each at 100 changes/sec:

Industrial Application Server Glossary. Appendix C

Industrial Application Server Glossary. Appendix C Industrial Application Server Glossary Appendix C C-2 Appendix C Industrial Application Server Glossary Application A collection of objects within a Galaxy Repository that performs an automation task.

More information

Wonderware Application Server User s Guide Invensys Systems, Inc.

Wonderware Application Server User s Guide Invensys Systems, Inc. Wonderware Application Server User s Guide Invensys Systems, Inc. Revision B Last Revision: 11/13/08 Copyright 2008 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part of this documentation

More information

Object Viewer User s Guide

Object Viewer User s Guide Wonderware Object Viewer User s Guide 9/7/12 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying,

More information

Wonderware FactorySuite

Wonderware FactorySuite Wonderware FactorySuite IndustrialSQL Server Historian Administration Guide Revision E Last Revision: 7/13/05 Invensys Systems, Inc. All rights reserved. No part of this documentation shall be reproduced,

More information

ArchestrA Log Flag Editor User s Guide Invensys Systems, Inc.

ArchestrA Log Flag Editor User s Guide Invensys Systems, Inc. ArchestrA Log Flag Editor User s Guide Invensys Systems, Inc. Revision B Last Revision: 10/24/08 Copyright 2008 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part of this documentation

More information

ArchestrA Web Exporter Guide

ArchestrA Web Exporter Guide Wonderware ArchestrA Web Exporter Guide 9/19/14 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical,

More information

Wonderware DAServer 1.0 for Mitsubishi Ethernet User s Guide

Wonderware DAServer 1.0 for Mitsubishi Ethernet User s Guide Wonderware DAServer 1.0 for Mitsubishi Ethernet User s Guide Invensys Systems, Inc. Revision A Last Revision: 9/15/06 Copyright 2006 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No

More information

Historian Administration Guide

Historian Administration Guide Wonderware Historian Administration Guide 8/17/10 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical,

More information

Wonderware Wonderware ArchestrA License Manager Guide

Wonderware Wonderware ArchestrA License Manager Guide Wonderware Wonderware ArchestrA License Manager Guide 10/18/12 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic,

More information

Wonderware DAServer 1.0 for Omron FINS Ethernet User s Guide

Wonderware DAServer 1.0 for Omron FINS Ethernet User s Guide Wonderware DAServer 1.0 for Omron FINS Ethernet User s Guide Invensys Systems, Inc. Revision A Last Revision: 5/22/07 Copyright 2007 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No

More information

InBatch Installation Guide. Invensys Systems, Inc.

InBatch Installation Guide. Invensys Systems, Inc. InBatch Installation Guide Invensys Systems, Inc. Revision A Last Revision: August 24, 2010 Copyright 2010 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part of this documentation

More information

Wonderware DAServer for Omron FINS Ethernet User s Guide

Wonderware DAServer for Omron FINS Ethernet User s Guide Wonderware DAServer for Omron FINS Ethernet User s Guide Invensys Systems, Inc. Revision B Last Revision: 10/26/07 Copyright 2007 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part

More information

Wonderware InTouch HMI Getting Started Guide

Wonderware InTouch HMI Getting Started Guide Wonderware InTouch HMI Getting Started Guide Invensys Systems, Inc. August 26, 2014 Copyright 2008-2014 Invensys Systems, Inc. All Rights Reserved. Invensys is a Schneider Electric company. All rights

More information

Wonderware Production Events Module v. 1.0 (PEM)

Wonderware Production Events Module v. 1.0 (PEM) Wonderware Production Events Module v. 1.0 (PEM) Deployment Guide Revision A Last Revision: 7/11/2005 Invensys Systems, Inc. INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE 2005 by Invensys

More information

Information Server Administration Guide

Information Server Administration Guide Wonderware Information Server Administration Guide 8/28/12 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic,

More information

Comprehensive Training for Wonderware System Platform

Comprehensive Training for Wonderware System Platform Comprehensive Training for Wonderware System Platform Application Server and InTouch for System Platform Course Outline The Wonderware System Platform Comprehensive course is a 5-day, instructor-led course

More information

Wonderware DAServer for Omron FINS Serial User s Guide

Wonderware DAServer for Omron FINS Serial User s Guide Wonderware DAServer for Omron FINS Serial User s Guide Invensys Systems, Inc. Revision B Last Revision: 10/26/07 Copyright 2007 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part

More information

Wonderware Information Server Win-XML Exporter User s Guide. Invensys Systems, Inc.

Wonderware Information Server Win-XML Exporter User s Guide. Invensys Systems, Inc. Wonderware Information Server Win-XML Exporter User s Guide Invensys Systems, Inc. Revision D Last Revision: February 22, 2010 Copyright 2003-2007, 2009-2010 Invensys Systems, Inc. All Rights Reserved.

More information

InTouch 8.0. InTouch 8.0. Data Sheet. Process Visualization OVERVIEW POWER AND VERSATILITY

InTouch 8.0. InTouch 8.0. Data Sheet. Process Visualization OVERVIEW POWER AND VERSATILITY Data Sheet InTouch 8.0 Process Visualization Wonderware InTouch 8.0 is a powerful graphical human-machine-interface (HMI) for industrial automation, process control and supervisory monitoring. OVERVIEW

More information

Course Description. InBatch Software

Course Description. InBatch Software Course Description INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 by Invensys Systems, Inc. All rights reserved. No part of this document may be reproduced, stored in or introduced

More information

Wonderware ArchestrA System Platform in a Virtualized Environment Implementation Guide

Wonderware ArchestrA System Platform in a Virtualized Environment Implementation Guide Wonderware ArchestrA System Platform in a Virtualized Environment Implementation Guide All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted

More information

The Benefits of Component Object- Based SCADA and Supervisory System Application Development

The Benefits of Component Object- Based SCADA and Supervisory System Application Development The Benefits of Component Object- Based SCADA and Supervisory System Application Development By Steven D. Garbrecht, Marketing Program Manager for Infrastructure and Platforms Table of Contents 1. Overview...

More information

Wonderware. Historian Installation Guide

Wonderware. Historian Installation Guide Wonderware Historian Installation Guide August 2010 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical,

More information

Operator actions are initiated in visualization nodes, processed in dedicated server nodes, and propagated to other nodes requiring it.

Operator actions are initiated in visualization nodes, processed in dedicated server nodes, and propagated to other nodes requiring it. Tech Note 671 Wonderware System Platform: Optimizing I/O Performance All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use

More information

Wonderware PAC. User Guide. HA Issue 7 June 2017

Wonderware PAC. User Guide. HA Issue 7 June 2017 Wonderware PAC User Guide HA030834 Issue 7 June 2017 Table of Contents Table of Contents... 2 Preface... 5 Revision Information... 5 Documentation Conventions... 5 Acronyms... 5 Reference Documents...

More information

Wonderware PAC. User Guide HA030834/6. June 2015 (Issue 6)

Wonderware PAC. User Guide HA030834/6. June 2015 (Issue 6) Wonderware PAC User Guide HA030834/6 June 2015 (Issue 6) 2015 All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it

More information

Introduction. Upgrading from Previous InTouch Versions. Upgrading from InTouch Version 7.11

Introduction. Upgrading from Previous InTouch Versions. Upgrading from InTouch Version 7.11 Tech Note 511 InTouch 10.0 & Wonderware Application Server 3.0 System Upgrade and Application/Galaxy Migration Steps All Tech Notes and KBCD documents and software are provided "as is" without warranty

More information

Wonderware. Historian Glossary 8/16/10

Wonderware. Historian Glossary 8/16/10 Wonderware Historian Glossary 8/16/10 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying,

More information

Wonderware. ABTCP DAServer User s Guide. Wonderware. Version 1.5 Last Revision: 3/21/07

Wonderware. ABTCP DAServer User s Guide. Wonderware. Version 1.5 Last Revision: 3/21/07 Wonderware Version 1.5 Last Revision: 3/21/07 Wonderware All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical,

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31S-10B11 B3 Wonderware Historian Wonderware Historian, a component of the ArchestrA System Platform, is a powerful and integrated database

More information

Wonderware FactorySuite

Wonderware FactorySuite Wonderware FactorySuite InTouch Supplementary Components User s Guide Revision 2.0 Last Revision: 2005 Invensys Systems, Inc. All rights reserved. No part of this documentation shall be reproduced, stored

More information

System Platform Design Guidelines

System Platform Design Guidelines Ground floor Block D Gillooly s View Office Park 1 Osborne Road Bedfordview Tel: 0861-WONDER Fax: (011) 607-8478 System Platform Design Guidelines Design guidelines for System Platform implementations

More information

2014 Software Global Client Conference

2014 Software Global Client Conference What's New in System Platform 2014 R2 WW HMI SCADA-03 (R) Alvaro Martinez Wonderware System Platform 2014 R2 Simply Amazing! Wonderware System Platform 2014 R2 Application Server Historian InTouch Historian

More information

Wonderware. SuiteVoyager Deployment Guide. Invensys Systems, Inc. Revision A Last Revision: 5/23/02

Wonderware. SuiteVoyager Deployment Guide. Invensys Systems, Inc. Revision A Last Revision: 5/23/02 Wonderware SuiteVoyager Deployment Guide Revision A Last Revision: 5/23/02 Invensys Systems, Inc. All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or

More information

Wonderware. S7SIMATIC DAServer User s Guide. Invensys Systems, Inc. Version 3.0 Last Revision: 2/25/13

Wonderware. S7SIMATIC DAServer User s Guide. Invensys Systems, Inc. Version 3.0 Last Revision: 2/25/13 Wonderware Version 3.0 Last Revision: 2/25/13 Invensys Systems, Inc. Copyright 2013 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part of this documentation shall be reproduced, stored

More information

InFusion SOFTWARE Product Specifications

InFusion SOFTWARE Product Specifications InFusion SOFTWARE Product Specifications PSS 21S-10G7 B3 InFusion SCADA 2.0 Software InFusion SCADA is a module of the InFusion Enterprise Control System [ECS]. It comprises a set of ArchestrA application

More information

Wonderware GESRTP DAServer User s Guide Invensys Systems, Inc.

Wonderware GESRTP DAServer User s Guide Invensys Systems, Inc. Wonderware Invensys Systems, Inc. Revision 1.5 Last Revision: 2/19/07 Copyright 2006, 2007 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part of this documentation shall be reproduced,

More information

White Paper. The Benefits of Object-Based Architectures for SCADA and Supervisory Systems. What s Inside:

White Paper. The Benefits of Object-Based Architectures for SCADA and Supervisory Systems. What s Inside: White Paper The Benefits of Object-Based Architectures for SCADA and Supervisory Systems Author: Steven D. Garbrecht, Vice President of Software and Advanced Applications Marketing, Invensys Operations

More information

Wonderware. FactorySuite Gateway User s Guide. Invensys Systems, Inc. Version A Last Revision: 6/21/04

Wonderware. FactorySuite Gateway User s Guide. Invensys Systems, Inc. Version A Last Revision: 6/21/04 Wonderware FactorySuite Gateway User s Guide Version A Last Revision: 6/21/04 Invensys Systems, Inc. All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system,

More information

Wonderware Industrial Computers Extending the Power of Wonderware Everywhere

Wonderware Industrial Computers Extending the Power of Wonderware Everywhere Wonderware Industrial Computers Extending the Power of Wonderware Everywhere Wonderware Industrial Computers Extraordinary Value! Wonderware InTouch HMI is the world s favorite HMI software used by more

More information

Wonderware. OPCLink User s Guide. Invensys Systems, Inc. Revision I Last Revision: April 2004

Wonderware. OPCLink User s Guide. Invensys Systems, Inc. Revision I Last Revision: April 2004 Wonderware OPCLink User s Guide Revision I Last Revision: April 2004 Invensys Systems, Inc. All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted

More information

Wonderware. ABDHPLUS DAServer User s Guide. Invensys Systems, Inc. Version 1.5 Last Revision: 2/5/07

Wonderware. ABDHPLUS DAServer User s Guide. Invensys Systems, Inc. Version 1.5 Last Revision: 2/5/07 Wonderware Version 1.5 Last Revision: 2/5/07 Invensys Systems, Inc. All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic,

More information

2014 Software Global Client Conference

2014 Software Global Client Conference WW HMI SCADA-10 Best practices for distributed SCADA Stan DeVries Senior Director Solutions Architecture What is Distributed SCADA? It s much more than a distributed architecture (SCADA always has this)

More information

WW HMI SCADA Connectivity and Integration - Multi-Galaxy

WW HMI SCADA Connectivity and Integration - Multi-Galaxy Slide 1 WW HMI SCADA-06 2014 Connectivity and Integration - Multi-Galaxy Steven L. Weygandt Portfolio Product Manager - Device Integration /Wonderware Social.Invensys.com @InvensysOpsMgmt / #SoftwareRevolution

More information

file:///media/rhandsome/toshiba/wonderware/do... Wonderware InTouch HMI Version 10.1 Readme

file:///media/rhandsome/toshiba/wonderware/do... Wonderware InTouch HMI Version 10.1 Readme Wonderware InTouch HMI Version 10.1 Readme Last revision: 01/30/2009 This document contains important information about Wonderware InTouch HMI Version 10.1. Review this document for known issues and changes

More information

Guidelines to Setting up Wonderware's FSGateway Version 1.0

Guidelines to Setting up Wonderware's FSGateway Version 1.0 Guidelines to Setting up Wonderware's FSGateway Version 1.0 Wonderware s new FSGateway provides the robust protocol conversion tool that many Wonderware users have been asking for. As part of the DAServer

More information

Wonderware InTouch HMI Version 10 Readme. About This Release. System Requirements. ArchestrA Integration. ArchestrA Graphics

Wonderware InTouch HMI Version 10 Readme. About This Release. System Requirements. ArchestrA Integration. ArchestrA Graphics Wonderware InTouch HMI Version 10 Readme Last revision: 08/14/2007 This document contains the latest information about Wonderware InTouch HMI version 10. Review this document for descriptions of new features,

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications Wonderware Historian Client Wonderware Historian Client, previously known as ActiveFactory software, consists of a set of powerful tools and

More information

Installation Guide Worksoft Certify

Installation Guide Worksoft Certify Installation Guide Worksoft Certify Worksoft, Inc. 15851 Dallas Parkway, Suite 855 Addison, TX 75001 www.worksoft.com 866-836-1773 Worksoft Certify Installation Guide Version 9.0.3 Copyright 2017 by Worksoft,

More information

Wonderware FactorySuite InTrack Deployment Guide

Wonderware FactorySuite InTrack Deployment Guide Wonderware FactorySuite InTrack Deployment Guide May 2002 Wonderware Corporation 2002 Invensys Systems, Inc. All rights reserved. No part of the material protected by this copyright may be reproduced or

More information

Tech Note 989 Historizing AppServer Objects to Partner Historians and Retrieving Data Using HistClient Trend

Tech Note 989 Historizing AppServer Objects to Partner Historians and Retrieving Data Using HistClient Trend Tech Note 989 Historizing AppServer Objects to Partner Historians and Retrieving Data Using HistClient Trend All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty

More information

ProfessionalPLUS Station Software Suite

ProfessionalPLUS Station Software Suite DeltaV Distributed Control System Product Data Sheet February 2018 ProfessionalPLUS Station Software Suite Global database, architected for flexibility and scalability Powerful, graphical engineering capabilities

More information

Microsoft Office Groove Server Groove Manager. Domain Administrator s Guide

Microsoft Office Groove Server Groove Manager. Domain Administrator s Guide Microsoft Office Groove Server 2007 Groove Manager Domain Administrator s Guide Copyright Information in this document, including URL and other Internet Web site references, is subject to change without

More information

Siebel Application Deployment Manager Guide. Version 8.0, Rev. A April 2007

Siebel Application Deployment Manager Guide. Version 8.0, Rev. A April 2007 Siebel Application Deployment Manager Guide Version 8.0, Rev. A April 2007 Copyright 2005, 2006, 2007 Oracle. All rights reserved. The Programs (which include both the software and documentation) contain

More information

Relativity Designer Installation Guide

Relativity Designer Installation Guide Liant Software Corporation Relativity Designer Installation Guide Version 5 Copyright 1994-2003 by Liant Software Corporation. All rights reserved. Printed in U.S.A. No part of this publication may be

More information

Altiris Software Management Solution 7.1 from Symantec User Guide

Altiris Software Management Solution 7.1 from Symantec User Guide Altiris Software Management Solution 7.1 from Symantec User Guide Altiris Software Management Solution 7.1 from Symantec User Guide The software described in this book is furnished under a license agreement

More information

Introduction. Application Versions. Device Integration Objects. Tech Note 879 Redundant Device Integration Object Scan Mode Behaviors

Introduction. Application Versions. Device Integration Objects. Tech Note 879 Redundant Device Integration Object Scan Mode Behaviors Tech Note 879 Redundant Device Integration Object Scan Mode Behaviors All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use

More information

Bill Parrish Scott Inscore Bob Worth

Bill Parrish Scott Inscore Bob Worth Bill Parrish Scott Inscore Bob Worth A Systems Integration Company, Providing Automation and SCADA Solutions. teampiedmont.com a Full-Service, Turn Key Solution: An integrated team of engineers & designers

More information

Veeam Endpoint Backup

Veeam Endpoint Backup Veeam Endpoint Backup Version 1.5 User Guide March, 2016 2016 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may be reproduced,

More information

UCOS User-Configurable Open System

UCOS User-Configurable Open System UCOS User-Configurable Open System User-Configurable Open System (UCOS) UCOS is a complete control system solution. It includes graphical development software, a graphical human machine interface (HMI),

More information

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.2) Security information 1. Preface 2. Basics 3. Installation and licensing 4. PCS 7 Engineering 5

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.2) Security information 1. Preface 2. Basics 3. Installation and licensing 4. PCS 7 Engineering 5 Security information 1 Preface 2 SIMATIC PCS 7 process control system Function Manual Basics 3 Installation and licensing 4 PCS 7 Engineering 5 Plant configurations 6 OpenPCS 7 interface 7 Appendix Lists

More information

SAS Model Manager 2.2. Tutorials

SAS Model Manager 2.2. Tutorials SAS Model Manager 2.2 Tutorials The correct bibliographic citation for this manual is as follows: SAS Institute Inc. 2009. SAS Model Manager 2.2: Tutorials. Cary, NC: SAS Institute Inc. SAS Model Manager

More information

HP Database and Middleware Automation

HP Database and Middleware Automation HP Database and Middleware Automation For Windows Software Version: 10.10 SQL Server Database Refresh User Guide Document Release Date: June 2013 Software Release Date: June 2013 Legal Notices Warranty

More information

1.0. Quest Enterprise Reporter Discovery Manager USER GUIDE

1.0. Quest Enterprise Reporter Discovery Manager USER GUIDE 1.0 Quest Enterprise Reporter Discovery Manager USER GUIDE 2012 Quest Software. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide

More information

HP Intelligent Management Center SOM Administrator Guide

HP Intelligent Management Center SOM Administrator Guide HP Intelligent Management Center SOM Administrator Guide Abstract This guide contains comprehensive conceptual information for network administrators and other personnel who administrate and operate the

More information

IBM Proventia Management SiteProtector Policies and Responses Configuration Guide

IBM Proventia Management SiteProtector Policies and Responses Configuration Guide IBM Internet Security Systems IBM Proventia Management SiteProtector Policies and Responses Configuration Guide Version2.0,ServicePack8.1 Note Before using this information and the product it supports,

More information

Proficy* HMI/SCADA - ifix LAN R EDUNDANCY

Proficy* HMI/SCADA - ifix LAN R EDUNDANCY Proficy* HMI/SCADA - ifix LAN R EDUNDANCY Version 5.5 February 2012 All rights reserved. No part of this publication may be reproduced in any form or by any electronic or mechanical means, including photocopying

More information

SIMATIC. PCS 7 process control system OpenPCS 7. Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

SIMATIC. PCS 7 process control system OpenPCS 7. Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5 Preface 1 Basics 2 SIMATIC PCS 7 process control system Function Manual Installation and licensing 3 PCS 7 Engineering 4 System configurations 5 interface 6 Appendix A Lists and folders B Valid for PCS

More information

Management Console for SharePoint

Management Console for SharePoint Management Console for SharePoint User Guide Copyright Quest Software, Inc. 2009. All rights reserved. This guide contains proprietary information, which is protected by copyright. The software described

More information

GE Intelligent Platforms

GE Intelligent Platforms GE Intelligent Platforms PAC8000 Hybrid Workbench Powerful software for advanced control strategies PAC8000 Strategy Builder for process control applications IEC 61131-3 software for logic control applications

More information

Template Summary. AT_Reactor_C2_Summary_R01. Accord Template Summary. Reactor 1 Configuration 2 : AT_Reactor_C2. Revision: R01 20 th Feb 2017

Template Summary. AT_Reactor_C2_Summary_R01. Accord Template Summary. Reactor 1 Configuration 2 : AT_Reactor_C2. Revision: R01 20 th Feb 2017 Accord Template Summary AT_Reactor_C2_Summary_R01 Document: System: Function: Accord Template Summary. Reactor 1 Configuration 2 : AT_Reactor_C2 8 Stage Reactor Revision: R01 20 th Feb 2017 AT_Reactor_C2_Summary_R01

More information

Accord Builder. User Guide

Accord Builder. User Guide User Guide Document: V 3.6 User Guide R01 V3.6 User Guide R01 Page 1 of 110 Table of Contents 1 Introduction... 7 2 General Summary and Definitions... 8 2.1 Accord Platform and Plant... 8 2.2 PLC Control

More information

. SECTION SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM

. SECTION SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM . SECTION 13380 - SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM PART 1 - GENERAL 1.01 WORK OF THIS SECTION A. The CONTRACTOR shall furnish, install, configure, program, test and put into operation the

More information

Wonderware Operations Integration Supervisory AutomationDirect ADPRO Server (G-1.2 Series)

Wonderware Operations Integration Supervisory AutomationDirect ADPRO Server (G-1.2 Series) Wonderware Operations Integration Supervisory AutomationDirect ADPRO Server (G-1.2 Series) Contents Contents WONDERWARE OPERATIONS INTEGRATION - SUPERVISORY AUTOMATIONDIRECT ADPRO SERVER (G-1.2 SERIES)...3

More information

Introduction. Application Versions. Virtual Machine Defined. Other Definitions. Tech Note 656 Building Wonderware Solution Architectures on VMware

Introduction. Application Versions. Virtual Machine Defined. Other Definitions. Tech Note 656 Building Wonderware Solution Architectures on VMware Tech Note 656 Building Wonderware Solution Architectures on VMware All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for

More information

Quest ChangeAuditor 5.1 FOR LDAP. User Guide

Quest ChangeAuditor 5.1 FOR LDAP. User Guide Quest ChangeAuditor FOR LDAP 5.1 User Guide Copyright Quest Software, Inc. 2010. All rights reserved. This guide contains proprietary information protected by copyright. The software described in this

More information

Administrator s Guide

Administrator s Guide Administrator s Guide 1995 2011 Open Systems Holdings Corp. All rights reserved. No part of this manual may be reproduced by any means without the written permission of Open Systems, Inc. OPEN SYSTEMS

More information

Microsoft SQL Server Training Course Catalogue. Learning Solutions

Microsoft SQL Server Training Course Catalogue. Learning Solutions Training Course Catalogue Learning Solutions Querying SQL Server 2000 with Transact-SQL Course No: MS2071 Two days Instructor-led-Classroom 2000 The goal of this course is to provide students with the

More information

Wonderware OMRON FinsGateway I/O Server

Wonderware OMRON FinsGateway I/O Server Wonderware OMRON FinsGateway I/O Server User s Guide Revision C June 2001 Wonderware Corporation All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or

More information

The Value of Certification in the Wonderware Solution Provider Program. By Jay S. David, Senior Product Marketing Specialist

The Value of Certification in the Wonderware Solution Provider Program. By Jay S. David, Senior Product Marketing Specialist The Value of Certification in the Wonderware Solution Provider Program By Jay S. David, Senior Product Marketing Specialist Table of Contents 1. The Advantages of Certification... 3 2. Demand for Wonderware

More information

Proficy* Workflow. Powered by Proficy SOA GETTING STARTED

Proficy* Workflow. Powered by Proficy SOA GETTING STARTED Proficy* Workflow Powered by Proficy SOA GETTING STARTED Version 1.5 SP4 February 2012 All rights reserved. No part of this publication may be reproduced in any form or by any electronic or mechanical

More information

Advanced Fieldbus Diagnostics, Without Fieldbus

Advanced Fieldbus Diagnostics, Without Fieldbus Advanced Fieldbus Diagnostics, Without Fieldbus 2005 ExperTune, Inc. Tom Kinney ExperTune, Inc. Advanced Fieldbus Diagnostics, Without Fieldbus Tom Kinney, ExperTune Inc. 2005 ExperTune Inc Summary Digital

More information

Introduction. Application Versions. Important. Tech Note 987 Configuring AppServer to Store Data in Primary and Partner Historians

Introduction. Application Versions. Important. Tech Note 987 Configuring AppServer to Store Data in Primary and Partner Historians Tech Note 987 Configuring AppServer to Store Data in Primary and Partner Historians All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the

More information

USER GUIDE. Rockwell Automation Publication RSSQL-UM001I-EN-P-June 2014

USER GUIDE. Rockwell Automation Publication RSSQL-UM001I-EN-P-June 2014 USER GUIDE Rockwell Automation Publication RSSQL-UM001I-EN-P-June 2014 Supersedes Publication RSSQL-UM001H-EN-P-April 2011 Contacting Rockwell Copyright Notice Trademark Notices Other Trademarks Warranty

More information

Quest Enterprise Reporter 2.0 Report Manager USER GUIDE

Quest Enterprise Reporter 2.0 Report Manager USER GUIDE Quest Enterprise Reporter 2.0 Report Manager USER GUIDE 2014 Quest Software, Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this

More information

Veritas System Recovery 18 Management Solution Administrator's Guide

Veritas System Recovery 18 Management Solution Administrator's Guide Veritas System Recovery 18 Management Solution Administrator's Guide Documentation version: 18 Legal Notice Copyright 2018 Veritas Technologies LLC. All rights reserved. Veritas and the Veritas Logo are

More information

Product Data Sheet DeltaV Operate for PROVOX July 2014 Page 1

Product Data Sheet DeltaV Operate for PROVOX July 2014 Page 1 July 2014 Page 1 DeltaV Operate for PROVOX Robust, scalable and secure operating desktop Redundant console data servers Alarms prioritized by user Powerful operator interface Introduction Today s evolving

More information

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide Copyright and Trademark Statements 2014 ViewSonic Computer Corp. All rights reserved. This document contains proprietary information that

More information

Quest Collaboration Services 3.6. Installation Guide

Quest Collaboration Services 3.6. Installation Guide Quest Collaboration Services 3.6 Installation Guide 2010 Quest Software, Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide

More information

Rapid Recovery DocRetriever for SharePoint User Guide

Rapid Recovery DocRetriever for SharePoint User Guide Rapid Recovery 6.1.3 Table of Contents Introduction to DocRetriever for SharePoint... 6 Using this documentation... 6 About DocRetriever for SharePoint...7 DocRetriever, AppAssure, and Rapid Recovery compatibility...

More information

System Platform Best Practice Guide 2014 R2

System Platform Best Practice Guide 2014 R2 System Platform Best Practice Guide 2014 R2 Contents Introduction... 2 Hardware and Architectural Considerations... 3 Virtual Environments... 5 Availability Environments... 6 InTouch application... 8 Redundancy...

More information

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3 Security information 1 Preface 2 SIMATIC Process control system PCS 7 Installation Manual PC components of a PCS 7 system 3 Hardware for PC stations 4 Installing PC stations 5 Appendices 6 Valid for PCS

More information

HPE Intelligent Management Center v7.3

HPE Intelligent Management Center v7.3 HPE Intelligent Management Center v7.3 Service Operation Manager Administrator Guide Abstract This guide contains comprehensive conceptual information for network administrators and other personnel who

More information

Installation Guide for Runtime Sybase Unwired Platform 2.1 ESD #1

Installation Guide for Runtime Sybase Unwired Platform 2.1 ESD #1 Installation Guide for Runtime Sybase Unwired Platform 2.1 ESD #1 Windows DOCUMENT ID: DC01698-01-0211-01 LAST REVISED: October 2012 Copyright 2012 by Sybase, Inc. All rights reserved. This publication

More information

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.1) Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.1) Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5 Preface 1 Basics 2 SIMATIC PCS 7 process control system Function Manual Installation and licensing 3 PCS 7 Engineering 4 System configurations 5 OpenPCS 7 interface 6 Appendix A Lists and folders B Valid

More information

Version 2017 Licensing Changes

Version 2017 Licensing Changes Version 2017 Licensing Changes Overview: There are a number of important licensing changes to InTouch and System Platform 2017. Existing Wonderware product versions can upgrade to either 2017 Perpetual

More information

Avalanche Remote Control User Guide. Version 4.1

Avalanche Remote Control User Guide. Version 4.1 Avalanche Remote Control User Guide Version 4.1 ii Copyright 2012 by Wavelink Corporation. All rights reserved. Wavelink Corporation 10808 South River Front Parkway, Suite 200 South Jordan, Utah 84095

More information

HC900 Hybrid Controller When you need more than just discrete control

HC900 Hybrid Controller When you need more than just discrete control HC900 Hybrid Controller When you need more than just discrete control Kepware OPC Server for HC900 Product Note Background OPC (OLE for Process Control ) is an emerging software standard that defines common

More information

ControlPoint. Advanced Installation Guide. September 07,

ControlPoint. Advanced Installation Guide. September 07, ControlPoint Advanced Installation Guide September 07, 2017 www.metalogix.com info@metalogix.com 202.609.9100 Copyright International GmbH., 2008-2017 All rights reserved. No part or section of the contents

More information

Oil and Gas SCADAvantage TM Product Update version ABB

Oil and Gas SCADAvantage TM Product Update version ABB Oil and Gas SCADAvantage TM Product Update version 5.6.3 ABB 3 SCADAvantage Product Update version 5.6.3 Notice Trademarks This document contains information about one or more ABB products and may include

More information