DICOM Conformance Statement Radiotherapy Document Revision 2 July 1, Copyright Brainlab AG

Size: px
Start display at page:

Download "DICOM Conformance Statement Radiotherapy Document Revision 2 July 1, Copyright Brainlab AG"

Transcription

1 Document Revision 2 July 1, Copyright Brainlab AG

2

3 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab system. This system dependent from purchased licenses and configuration consists of several applications and performers. Applications Content Manager DICOM DICOM Proxy Application 1... Performers Application N Performer 1... Performer N Figure 1-1: Overview of a Brainlab system running applications and performers The Brainlab system is based on the following common management applications: Management Application Content Manager DICOM Proxy Description Manages applications on Brainlab systems. It allows a user to create and read screenshots. The interface between the Brainlab system and the outside DICOM world. No application or performer communicates directly with any remote DICOM node, but all communication will be done through the DICOM Proxy. If necessary the DICOM Proxy adjusts the DI- COM communication to the capabilities and known specialties of the remote DICOM nodes. The DICOM Proxy itself (see [1] for its Conformance Statement) as well as the internal communication between the DICOM Proxy and the applications and performers is not part of this Conformance Statement. Table 1-1: Common Management Applications Applications have a user interface. The following applications are documented in this Conformance Statement: Application Patient Selection Image Viewer Fusion Smartbrush Description Allows the user to browse, load or save data in/to DICOM archives or on/to media (e.g., CD-ROM) Allows the user to display any kind of DICOM image data. Allows the user to overlap two different DICOM data sets Allows the user to create, read and update segmentations based on DICOM image data. July 1, 2014 Document Revision 2 Page 3 of 89

4 Content Manager Patient Selection Image Viewer Fusion Smartbrush Brain Metastases Dose Review AHSA Auto Segmentation DICOM RT Export DICOM Conformance Statement Application Brain Metastases Dose Review Adaptive Hybrid Surgery Analysis (AHSA) Description Reads images and segmentations and allows to create an indication-driven radiotherapy treatment plan for multiple brain metastases. Final treatment plans can be exported to third-party systems for treatment or evaluation. Enables the user to review therapeutic volume dose based on image and structure information. Reads images, segmentations and registrations and allows the user to evaluate intraoperative data. Table 1-2: Applications Performers don t have a user interface and perform their tasks in the background. The following performers are documented in this Conformance Statement: Performer Auto Segmentation DICOM RT Export Description Performs segmentation tasks in the background. Conversion of 3D objects and registration (fusion) data to DICOM RT compliant format. Table 1-3: Performers The table below addresses all supported network services used by the different surgery application entities. For the SOP Classes in the Transfer section SCU and SCP have special meanings. Entities consuming data (e.g., for displaying images) are marked as SCP. Applications producing data (e.g., like spatial registrations) are marked as SCU. All created data will be initially stored to the DICOM Proxy, which then is responsible to forward created data to configured remote DICOM nodes. Symbol: Meaning: User of Service (SCU) Provider of Service (SCP) Both (SCU/SCP) SOP Classes Transfer Breast Tomosynthesis Image Storage Computed Radiography Image Storage CT Image Storage Digital Intra-oral X-Ray Image Storage - For Presentation Digital Intra-oral X-Ray Image Storage - For Processing Digital Mammography X-Ray Image Storage - For Presentation Digital Mammography X-Ray Image Storage - For Processing Digital X-Ray Image Storage - For Presentation Digital X-Ray Image Storage - For Processing Page 4 of 89 Document Revision 2 July 1, 2014

5 Content Manager Patient Selection Image Viewer Fusion Smartbrush Brain Metastases Dose Review AHSA Auto Segmentation DICOM RT Export DICOM Conformance Statement SOP Classes Encapsulated PDF Storage Enhanced CT Image Storage Enhanced MR Color Image Storage Enhanced MR Image Storage Enhanced PET Image Storage Enhanced US Volume Storage Enhanced XA Image Storage Enhanced XRF Image Storage Grayscale Softcopy Presentation State Storage Intravascular Optical Coherence Tomography Image Storage - For Presentation Intravascular Optical Coherence Tomography Image Storage - For Processing Key Object Selection Document Storage MR Image Storage MR Spectroscopy Storage Multi-frame Grayscale Byte Secondary Capture Storage Multi-frame Grayscale Word Secondary Capture Storage Multi-frame Single Bit Secondary Capture Storage Multi-frame True Color Secondary Capture Storage Nuclear Medicine Image Storage Nuclear Medicine Image Storage (Retired) Ophthalmic Photography 16 Bit Image Storage Ophthalmic Photography 8 Bit Image Storage Ophthalmic Tomography Image Storage Positron Emission Tomography Image Storage Raw Data Storage RT Dose Storage RT Plan Storage RT Structure Set Storage Secondary Capture Image Storage Segmentation Storage Spatial Fiducials Storage Spatial Registration Storage Surface Segmentation Storage Ultrasound Image Storage Ultrasound Image Storage (Retired) Ultrasound Multi-frame Image Storage Ultrasound Multi-frame Image Storage (Retired) Video Endoscopic Image Storage July 1, 2014 Document Revision 2 Page 5 of 89

6 Patient Selection Content Manager Patient Selection Image Viewer Fusion Smartbrush Brain Metastases Dose Review AHSA Auto Segmentation DICOM RT Export DICOM Conformance Statement SOP Classes Video Microscopic Image Storage Video Photographic Image Storage VL Endoscopic Image Storage VL Microscopic Image Storage VL Photographic Image Storage VL Slide-Coordinates Microscopic Image Storage VL Whole Slide Microscopy Image Storage X-Ray 3D Angiographic Image Storage X-Ray 3D Craniofacial Image Storage X-Ray Angiographic Bi-Plane Image Storage (Retired) X-Ray Angiographic Image Storage X-Ray Radiofluoroscopic Image Storage Query/Retrieve Patient Root Query/Retrieve Information Model - FIND Patient Root Query/Retrieve Information Model - GET Study Root Query/Retrieve Information Model - FIND Study Root Query/Retrieve Information Model - GET Table 1-4: Supported network services The next table addresses all supported Media Storage Application Profiles used by the different application entities. Symbol: Meaning: Read Files (FSR) Write Files (FSC or FSU) Both (FSR/FSC or FSU) Media Storage Application Profile Brainlab General Purpose Media Interchange Table 1-5: Supported media profiles Page 6 of 89 Document Revision 2 July 1, 2014

7 2 Table of Contents 1 Conformance Statement Overview 3 2 Table of Contents 7 3 Introduction Revision History Audience Remarks Abbreviations References Networking Implementation Model Application Data Flow Diagram Functional Definition of Application Entity (AE) Sequencing Of Real World Activities Application Entity Specifications Common Specifications Content Manager Specification Patient Selection Specification Image Viewer Specification Fusion Application Specification SmartBrush Application Specification Brain Metastases Application Specification Dose Review Application Specification Adaptive Hybrid Surgery Analysis (AHSA) Application Specification Auto Segmentation Performer Specification DICOM RT Export Performer Specification Network Interfaces Physical Network Interface Additional Protocols Media Interchange Implementation Model Application Data Flow Diagram Functional Definitions of AEs Sequencing of Real-World Activities File Meta Information Options AE Specifications Patient Selection Application Entity Specification Augmented and Private Application Profiles Augmented Application Profiles Private Application Profiles Support of Character Sets 49 7 Security Profiles Security Profiles Association Level Security Application Level Security Annexes IOD Contents July 1, 2014 Document Revision 2 Page 7 of 89

8 8.1.1 Supported SOP Instances Supported Modules Usage of Attributes from Received IODs Attribute Mapping Coerced/Modified fields Data Dictionary of Private Attributes Group Group 320B Group Group Group Coded Terminology and Templates TID 2010 Key Object Selection CID 7020 Document Titles CID 7151 Segmentation Property Types Grayscale Image Consistency Standard Extended/Specialized/Private SOP Classes Private Transfer Syntaxes Indexes Index of Tables Index of Figures Page 8 of 89 Document Revision 2 July 1, 2014

9 3 Introduction 3.1 Revision History Document Revision Date of Issue Author Description 2 April 2014 For review 3.2 Audience This document is intended for hospital staff, health system integrators, software designers or implementers. It is assumed that the reader has a working understanding of DICOM. 3.3 Remarks DICOM, by itself, does not guarantee interoperability. However, the Conformance Statement facilitates a first-level validation for interoperability between different applications supporting the same DICOM functionality. The Conformance Statement should be read and understood in conjunction with the DICOM Standard [2]. However, by itself it is not guaranteed to ensure the desired interoperability and a successful interconnectivity. The user should be aware of the following important issues: The comparison of different Conformance Statements is the first step towards assessing interconnectivity between Brainlab and non Brainlab equipment. This Conformance Statement is not intended to replace validation with other DICOM equipment to ensure proper exchange of information intended. The DICOM standard will evolve to meet the users future requirements. Brainlab reserves the right to make changes to its products or to discontinue its delivery. July 1, 2014 Document Revision 2 Page 9 of 89

10 3.4 Abbreviations There are a variety of terms and abbreviations used in the document that are defined in the DI- COM Standard. Abbreviations and terms are as follows: AE AET CD CD-R DVD FSC FSU FSR HD IOD ISO MOD PDU Q/R RT SCU SCP SOP DICOM Application Entity Application Entity Title Compact Disk Compact Disk Recordable Digital Versatile Disc File-Set Creator File-Set Updater File-Set Reader Hard Disk (DICOM) Information Object Definition International Standard Organization Magneto Optical Disk DICOM Protocol Data Unit Query and Retrieve DICOM Service Class User (DICOM client) DICOM Service Class Provider (DICOM server) DICOM Service-Object Pair 3.5 References [1] Brainlab, DICOM Conformance Statement DICOM Proxy 3.2, Feldkirchen: Brainlab, [2] Digital Imaging and Communications in Medicine (DICOM) 3.0, vol. PS 3, NEMA, [3] Brainlab, DICOM Conformance Statement DICOM Proxy 3.1, Feldkirchen: Brainlab, [4] IHE, IHE RO Technical Framework: Multimodality Image Registration for Radiation Oncology, IHE, [5] Varian, Varian System Server DICOM Conformance Statement, Varian, Page 10 of 89 Document Revision 2 July 1, 2014

11 4 Networking 4.1 Implementation Model Application Data Flow Diagram DICOM Proxy Query for Patients, Studies and Series Patient Selection Remote Performs Query/Retrieve DICOM Standard Interface Figure 4-1: Patient Selection Application Data Flow Diagram Brainlab applications in general support several data flows. Either they receive any DICOM data to display it, to process it and/or to create new DICOM data. Display DICOM Proxy Remote Sends Data Process Brainlab Application Remote Receives Data Create DICOM Standard Interface Figure 4-2: General Application Data Flow Diagram July 1, 2014 Document Revision 2 Page 11 of 89

12 Brainlab Performers only have one data flow. They process received DICOM data and create new DICOM data out of it. DICOM Proxy Process Remote Sends Data Brainlab Performer Create Remote Receives Data DICOM Standard Interface Figure 4-3: General Performer Data Flow Diagram Functional Definition of Application Entity (AE) All communication is done through the DICOM Proxy except for the Brain Metastases Application that can directly send data to a remote node, configured within the application s export platforms. If there is an appropriate configuration for a remote node any DICOM command or message may be forwarded to the configured remote node. In this case the DICOM Proxy may act as protocol converter, i.e., it converts DICOM commands and messages in a DICOM format the remote node understands. If there is no remote node configured the data will be retrieved from and stored in the local storage of the DICOM Proxy Applications Management Applications Content Manager It allows the user to create screenshots. It stores them via the DICOM Storage Service Class as DICOM Secondary Capture Applications Patient Selection It allows the user to query remote archives using the DICOM Query/Retrieve FIND SOP Classes and to retrieve data using the DICOM Query/Retrieve GET SOP Class to generate previews. Page 12 of 89 Document Revision 2 July 1, 2014

13 Image Viewer It displays all kind of DICOM image data received via the DICOM Storage Service Class. Additionally it is able to save changes, e.g., changes to the VOI LUT as Grayscale Presentation State. Fusion It allows the user to create or change spatial registrations between different volumetric image sets received via the DICOM Storage Service Class. Smartbrush It allows the user to create or change DICOM Segmentation instances based on loaded image sets received via the DICOM Storage Service Class. Additionally, it can save volumetric reports as DICOM Encapsulated PDF. Brain Metastases The Brain Metastases application provides optimized planning and display for cranial multimetastases radiation planning. It requests DICOM image, Segmentation and Registration instances received via the DICOM Storage Service Class. It creates DICOM RT Structure Set, RT Plan and RT Dose instances and sends these along the image instances to a defined target system. Dose Review The Dose Review application contains features for review of isodose lines, review of DVHs, dose comparison and summation. It requests DICOM image, Registration, RT Structure Set, RT Plan and RT Dose instances received via the DICOM Storage Service Class. It does not create any new DICOM instances. Adaptive Hybrid Surgery Analysis The Adaptive Hybrid Surgery Analysis application simulates an automated template-based radiation treatment plan based on DICOM image, Segmentation and Registration instances received via the DICOM Storage Service Class Performer Auto Segmentation Background service to create organ segmentations based on DICOM volumetric image sets received via the DICOM Storage Service Class. DICOM RT Export Background service to create vessel segmentations based on DICOM volumetric image sets received via the DICOM Storage Service Class. July 1, 2014 Document Revision 2 Page 13 of 89

14 4.1.3 Sequencing Of Real World Activities Standard Interactive Use Case In the standard use case normally the user selects a patient in the Patient Selection Application or some data to work with (1). Afterwards, the application is started (2) and requests the data (3). The DICOM Proxy retrieves from the configured remote nodes 1 the requested data (4) and passes it through to the requesting application (5). If the application creates any data it optionally will be sent to a remote system (6). Patient Selection Application DICOM Proxy Remote System (1) Query/Retrieve C-FIND (2) Invoke Application (3) Query/Retrieve C-GET (4) Query/Retrieve C-MOVE/GET loop (5) Storage C-STORE Whether created instances shall be stored depends on the application opt (6) Storage C-STORE Figure 4-4: Simplified sequencing of the standard interactive use case. The sequencing is not only possible between the Patient Selection and an Application but also between two or more different applications, i.e., it is possible to build a chain of applications, each performing a special task. This chain then is controlled by the Content Manager Performer In general a performer is invoked as soon as new data arrives at the DICOM Proxy (1). Via internal communication (not part of this Conformance Statement) the Performer is informed about the new data and - if it is able to process the data requests it (3,4). The Performer processes the data (5) and, if the Performer creates new instances, it can send the created data to the DI- COM Proxy, which may automatically forward it to a remote node (6). 1 The DICOM Proxy adjusts all queries to the addressed remote node, e.g., it automatically converts Query/Retrieve C-GET requests for nodes not supporting this command to C-MOVE requests. Page 14 of 89 Document Revision 2 July 1, 2014

15 Performer DICOM Proxy Remote System 1 Remote System 2 (1) Storage C-STORE ref (2) Notification (3) Query/Retrieve C-GET Internal mechanisms beyond the scope of this Conformance Statement loop (4) Storage C-STORE (5) Any Performer Action opt (6) Storage C-STORE Figure 4-5: Simplified sequencing of Performer activities. July 1, 2014 Document Revision 2 Page 15 of 89

16 4.2 Application Entity Specifications Common Specifications This section describes the specifications valid for all application entities in this Conformance Statement. In successive application entity sections only the differences or additional information will be described SOP Classes and Transfer Syntaxes This section only describes commonly used SOP Classes and Transfer Syntaxes. Whether they supported as SCU or SCP will be described in the sub sections of the appropriate application entity. In the following table all transfer syntaxes supported by any of the applications are listed: List Name / Transfer Syntax Name Transfer Syntax List With No Compression List Short Name / Transfer Syntax UID NOCOMP DICOM Explicit VR Little Endian DICOM Explicit VR Big Endian DICOM Implicit VR Little Endian Transfer Syntax List With Lossless Compression Include Transfer Syntax List NOCOMP COMP JPEG Lossless, Non-Hierarchical, First-Order Prediction (Process 14) RLE Lossless Transfer Syntax List with RLE Compression RLE Lossless Include Transfer Syntax List NOCOMP RLE IMPL DICOM Implicit VR Little Endian Transfer Syntax List With Lossy Compression Include Transfer Syntax List NOCOMP LOSSY JPEG Baseline (Process 1) Table 4-1: Commonly supported Transfer Syntaxes (for association negotiation) The transfer syntaxes are organized in so-called transfer syntax lists. For each presentation context specified by an application or performer, the name respectively short sign of the transfer syntax list is mentioned instead of repeating all the transfer syntaxes. Some applications and performers support the DICOM Storage Service Class. The following table contains the superset of supported Storage SOP Classes with the mapping to the accepted respectively proposed transfer syntax list. SOP Class Name Image Storage SOP Classes SOP Class UID Transfer Syntax List Breast Tomosynthesis Image Storage COMP Page 16 of 89 Document Revision 2 July 1, 2014

17 SOP Class Name SOP Class UID Transfer Syntax List Computed Radiography Image Storage COMP CT Image Storage COMP Digital Intra-oral X-Ray Image Storage - For Presentation COMP Digital Intra-oral X-Ray Image Storage - For Processing COMP Digital Mammography X-Ray Image Storage - For Presentation COMP Digital Mammography X-Ray Image Storage - For Processing COMP Digital X-Ray Image Storage - For Presentation COMP Digital X-Ray Image Storage - For Processing COMP Enhanced CT Image Storage COMP Enhanced MR Color Image Storage COMP Enhanced MR Image Storage COMP Enhanced PET Image Storage COMP Enhanced US Volume Storage COMP Enhanced XA Image Storage COMP Enhanced XRF Image Storage COMP Intravascular Optical Coherence Tomography Image Storage - For Presentation Intravascular Optical Coherence Tomography Image Storage - For Processing COMP COMP MR Image Storage COMP MR Spectroscopy Storage COMP Multi-frame Grayscale Byte Secondary Capture Storage COMP Multi-frame Grayscale Word Secondary Capture Storage COMP Multi-frame Single Bit Secondary Capture Storage COMP Multi-frame True Color Secondary Capture Storage LOSSY Nuclear Medicine Image Storage COMP Nuclear Medicine Image Storage (Retired) COMP Ophthalmic Photography 16 Bit Image Storage COMP Ophthalmic Photography 8 Bit Image Storage COMP Ophthalmic Tomography Image Storage COMP Positron Emission Tomography Image Storage COMP Secondary Capture Image Storage COMP Ultrasound Image Storage COMP Ultrasound Image Storage (Retired) COMP Ultrasound Multi-frame Image Storage COMP Ultrasound Multi-frame Image Storage (Retired) COMP Video Endoscopic Image Storage MPEG2 Video Microscopic Image Storage MPEG2 Video Photographic Image Storage MPEG2/MPEG4 VL Endoscopic Image Storage COMP VL Microscopic Image Storage COMP July 1, 2014 Document Revision 2 Page 17 of 89

18 SOP Class Name SOP Class UID Transfer Syntax List VL Photographic Image Storage COMP VL Slide-Coordinates Microscopic Image Storage COMP VL Whole Slide Microscopy Image Storage COMP X-Ray 3D Angiographic Image Storage COMP X-Ray 3D Craniofacial Image Storage COMP X-Ray Angiographic Bi-Plane Image Storage (Retired) COMP X-Ray Angiographic Image Storage COMP X-Ray Radiofluoroscopic Image Storage COMP Non-Image Storage SOP Classes Encapsulated PDF Storage NOCOMP Grayscale Softcopy Presentation State Storage NOCOMP Key Object Selection Document Storage NOCOMP Raw Data Storage NOCOMP RT Dose Storage IMPL RT Plan Storage IMPL 2 RT Structure Set Storage IMPL 2 Segmentation Storage RLE Spatial Fiducials Storage NOCOMP Spatial Registration Storage NOCOMP Surface Segmentation Storage NOCOMP Table 4-2: Commonly supported Storage SOP Classes with Transfer Syntax mapping Some applications and performers support the DICOM Query/Retrieve Service Class. The following table contains the superset of supported Query/Retrieve SOP Classes with the mapping to the accepted respectively proposed transfer syntax list. SOP Class Name FIND SOP Classes SOP Class UID Transfer Syntax List Patient Root Query/Retrieve Information Model FIND NOCOMP Study Root Query/Retrieve Information Model FIND NOCOMP GET SOP Classes Patient Root Query/Retrieve Information Model GET NOCOMP Study Root Query/Retrieve Information Model GET NOCOMP Table 4-3: Commonly supported Query/Retrieve SOP Classes with Transfer Syntax mapping The usage of these SOP Classes is specified in the sections with the detailed application specifications. 2 RT Dose, RT Plan and RT Structure Set Instances contain attributes with a VR of DS and a VM of 1-n (e.g., Contour Data (3006,0050) in RT Structure Sets). Implicit Little Endian transfer syntax allows storing of those attributes with a doubled length in comparison to explicit transfer syntax (4 byte length field vs. 2 byte length field). Page 18 of 89 Document Revision 2 July 1, 2014

19 Association Policies General The DICOM standard application context name for DICOM 3.0 is always proposed: Application Context Name Table 4-4: Commonly proposed Application Context Name Number of Associations Maximum number of simultaneous Associations (Initiator) Maximum number of simultaneous Associations (Acceptor) 10 (configurable) 10 (configurable) Table 4-5: Commonly supported number of associations Asynchronous Nature Applications or performers by default do not support asynchronous communication (multiple outstanding transactions over a single association). However if it is supported it is mentioned in the section of the affected application entity Implementation Identifying Information The implementation information for the application entities described in this document normally is hidden by the Brainlab DICOM Proxy (see [1] for its implementation identifying information). Therefore this information in the sections of the different application entities is purely informational Association Initiation Policy Brainlab applications and performers initiate associations in these cases: Find Studies, Series and Instances Initiated by applications and performers to find related studies, series and instances Get Studies, Series and Instances Initiated by applications and performers to retrieve related studies, series and instances If one of these activities is supported it is mentioned in the subsection of the appropriate application entity Activity Find Studies, Series and Instances Description and Sequencing of Activities Brainlab applications or performers initiate an association with the intention to find studies, series or instances and to retrieve them, e.g., because they are related to or referenced by a loaded data set. July 1, 2014 Document Revision 2 Page 19 of 89

20 Proposed Presentation Contexts Patient Root Query/Retrieve Information Model - FIND Study Root Query/Retrieve Information Model FIND Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg See Table 4-3 for the SOP Class / Transfer Syntax mapping Table 4-6: Commonly proposed Presentation Contexts - Find Studies, Series and Instances. SCU None SOP Specific Conformance Brainlab applications and performers provide standard conformance to the Patient and Study Root Query/Retrieve Information Model FIND SOP Classes. No extended negotiation is implemented. A C-FIND can be executed on all levels. On a lower level, all key attributes of the higher levels are included in the query (i.e. no relational queries are performed). Attribute Name Tag Types of Matching Patient Level (Patient Root Q/R Information Model) / Study Level (Study Root Q/R Information Model) Patient s Name (0010,0010) S, *, U Patient ID (0010,0020) S, *, U Patient's Birth Date (0010,0030) U Patient's Sex (0010,0040) U Study Level Study Date (0008,0020) S, R, U Accession Number (0008,0050) S, *, U Referring Physician's Name (0008,0090) S, *, U Study Instance UID (0020,000D) UNIQUE Study Time (0008,0030) U Study Description (0008,1030) U Modalities in Study (0008,0061) U SOP Classes in Study (0008,0062) U Number of Study Related Series (0020,1206) U Series Level Series Instance UID (0020,000E) UNIQUE Series Number (0020,0011) U Series Description (0008,103E) U Series Date (0008,0020) U Series Time (0008,0021) U Modality (0008,0060) U No. of Series Rel. Instances (0020,1209) U Instance Level SOP Instance UID (0008,0018) UNIQUE SOP Class UID (0008,0016) U Page 20 of 89 Document Revision 2 July 1, 2014

21 Attribute Name Tag Types of Matching Instance Number (0020,0013) U Instance Creation Date (0008,0012) U Instance Creation Time (0008,0013) U Arbitrary Search Keys as Requested by the Client * U Table 4-7: Patient Root and Study Root Request Identifier for FIND-SCU The types of Matching supported by the C-FIND SCU: S Single value matching R Range matching * Wildcard matching U Universal matching L UID list matching UNIQUE The unique key for the query level, (i.e. single value matching for levels below the current query level, either universal or single value matching for the current query level) Activity Get Studies, Series and Instances Description and Sequencing of Activities If the find operation doesn t provide icons for queried instances the Patient Selection automatically retrieves the instances and creates previews Proposed Presentation Contexts Patient Root Query/Retrieve Information Model - GET Study Root Query/Retrieve Information Model - GET Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg See Table 4-3 for the SOP Class / Transfer Syntax mapping All SCP Storage SOP Classes and SOP Class UIDs as defined in the respective application or performer specification See Table 4-2 for the SOP Class / Transfer Syntax mapping SCU SCP Table 4-8: Patient Selection proposed Presentation Contexts Find Patient None None SOP Specific Conformance The Patient Selection provides standard conformance to the DICOM Patient and Study Root Query/Retrieve - GET SOP Class and to the DICOM Storage SOP Classes. No extended negotiation is implemented Association Acceptance Policy Brainlab applications and performers do not directly accept associations. All external communication is handled by the DICOM Proxy (see [3] for details). Nevertheless in the sub sections of the different application entities the association acceptance will be described to define the SOP Classes they support. July 1, 2014 Document Revision 2 Page 21 of 89

22 Transfer Syntax Selection Policy Brainlab applications and performers in general accept transfer syntaxes in with no compression (explicit before implicit) before those with lossless compression and at least those with lossy compression. At least the order of the transfer syntaxes in the assigned transfer syntax list is the order of acceptance. Page 22 of 89 Document Revision 2 July 1, 2014

23 4.2.2 Content Manager Specification The Content Manager manages applications on Brainlab systems. It allows a user to create and read screenshots SOP Classes and Transfer Syntaxes The Content Manager provides standard conformance to the following SOP Classes: SOP Class Name SOP Class UID SCU SCP Multi Frame True Color SC Image Yes No Table 4-9: SOP Classes supported by the Content Manager Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> ContentManager Current possible versions are: <version> = Association Initiation Policy The Content Manager initiates an association in this case: Save Instances: Initiated to store created screenshots as secondary capture Activity Save Instances Description and Sequencing of Activities The user creates a screenshot. This screenshot is saved to the DICOM Proxy as Multi-frame True Color SC Image Proposed Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg Multi Frame True Color SC Image See Table 4-2 for the SOP Class / Transfer Syntax mapping Table 4-10: Content Manager proposed Presentation Contexts Save Instances SCU None SOP Specific Conformance The Content Manager provides standard conformance to the DICOM Storage SOP Classes. July 1, 2014 Document Revision 2 Page 23 of 89

24 4.2.3 Patient Selection Specification The Patient Selection allows the user to browse, import or export data in/to DICOM archives or on/to media (e.g., CD-ROM) SOP Classes and Transfer Syntaxes The Patient Selection provides standard conformance to the following SOP Classes: SOP Class Name SOP Class UID SCU SCP Storage All Image Storage SOP Classes and associated SOP Class UIDs as listed in Table 4-2 No Yes Key Object Selection Document Yes Yes Segmentation Storage No Yes Query/Retrieve Patient Root Query/Retrieve Information Model - FIND Yes No Patient Root Query/Retrieve Information Model - GET Yes No Study Root Query/Retrieve Information Model FIND Yes No Study Root Query/Retrieve Information Model GET Yes No Table 4-11: SOP Classes supported by the Patient Selection Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> PatientSelection Current possible versions are: <version> = Association Initiation Policy The Patient Selection initiates an association in these cases: Find Patient The user searches for a patient and related data. Display Preview During the search, for all queried instances, previews will be generated. If the find operation doesn t provide an appropriate preview icon, the instances will be retrieved and a preview will be created. Store Series Information: Key Object Selection instances are created to persist either plan information for a group of series or internal information about one series. Page 24 of 89 Document Revision 2 July 1, 2014

25 Activity Find Patient See Error! Reference source not found., section (Activity Find Studies, Series and Instances) Activity Display Preview See Error! Reference source not found., section (Activity Get Studies, Series and Instances), using Patient and Study Root Query/Retrieve Information Model GET and restricted to all SCP Storage SOP Classes and SOP Class UIDs as listed in Error! Reference source not found Activity Store Series Information Description and Sequencing of Activities For each series in a patient selected for further treatment the Patient Selection creates a Key Object Selection instance containing internal information. This KOS instance then is stored in the DICOM Proxy to be available for other applications and performers Proposed Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg Key Object Selection Document See Table 4-2 for the SOP Class / Transfer Syntax mapping Table 4-12: Patient Selection proposed Presentation Contexts Store Series Information SCU None SOP Specific Conformance The Patient Selection provides standard conformance to the DICOM Storage SOP Classes July 1, 2014 Document Revision 2 Page 25 of 89

26 4.2.4 Image Viewer Specification The Image Viewer Allows the user to display any kind of DICOM image data SOP Classes and Transfer Syntaxes The Image Viewer accepts the following SOP Classes for viewing: SOP Class Name SOP Class UID SCU SCP Storage All Image Storage SOP Classes and associated SOP Class UIDs as listed in Table 4-2 No Yes Encapsulated PDF No Yes Grayscale Softcopy Presentation State Yes Yes Key Object Selection Document No Yes Raw Data Yes Yes Segmentation Storage No Yes Spatial Registration Yes Yes Surface Segmentation Storage Yes Yes Query/Retrieve Study Root Query/Retrieve Information Model FIND Yes No Study Root Query/Retrieve Information Model GET Yes No Table 4-13: Image Viewer supported SOP Classes Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> ImageViewer Current possible versions are: <version> = Association Initiation Policy The Image Viewer initiates an association in these cases: Find Studies, Series and Instances Initiated to find related studies, series and instances Get Studies, Series and Instances Initiated to retrieve related studies, series and instances Save Instances: The user created a new instance Activity Find Studies, Series and Instances See Error! Reference source not found., section Page 26 of 89 Document Revision 2 July 1, 2014

27 Activity Get Studies, Series and Instances See Error! Reference source not found., section , restricted to Study Root Query/Retrieve Information Model GET and to all SCP Storage SOP Classes and SOP Class UIDs as listed in Table Activity Save Instances Description and Sequencing of Activities The user created a new instance: A new VOI LUT for a series. Will be stored as Grayscale Presentation State. A new Spatial Registration. A kind of nd-presentation State to re-display a series in 3D. Will be stored as Raw Data. A new trajectory. Will be stored as Surface Segmentation Proposed Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg All SCU Storage SOP Classes and SOP Class UIDs as listed in Table 4-13 See Table 4-2 for the SOP Class / Transfer Syntax mapping Table 4-14: Patient Selection proposed Presentation Contexts Store Instances SCU None SOP Specific Conformance The Image Viewer provides standard conformance to the DICOM Storage SOP Classes Activity Find Studies, Series and Instances See section July 1, 2014 Document Revision 2 Page 27 of 89

28 4.2.5 Fusion Application Specification The Fusion Application allows the user to overlap two different DICOM data sets SOP Classes and Transfer Syntaxes The Fusion Application accepts the following SOP Classes: SOP Class Name SOP Class UID SCU SCP Volumetric Images CT Image No Yes Enhanced CT Image No Yes Enhanced MR Image No Yes Multi Frame Grayscale Byte SC Image No Yes Multi Frame Grayscale Word SC Image No Yes Multi Frame Single Bit SC Image No Yes Multi Frame True Color SC Image No Yes MR Image No Yes NM Image No Yes NM Image Retired No Yes PET Image No Yes X-Ray 3D Angiographic Image No Yes X-Ray 3D Craniofacial Image No Yes Volumetric Other Spatial Registration Yes Yes Other Grayscale Softcopy Presentation State No Yes Key Object Selection Document No Yes Query/Retrieve Study Root Query/Retrieve Information Model FIND Yes No Study Root Query/Retrieve Information Model GET Yes No Table 4-15: Fusion Application supported SOP Classes Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> ImageFusion Current possible versions are: <version> = Association Initiation Policy The Fusion Application initiates an association in these cases: Page 28 of 89 Document Revision 2 July 1, 2014

29 Find Studies, Series and Instances Initiated to find related studies, series and instances Get Studies, Series and Instances Initiated to retrieve related studies, series and instances Save Fusion: The user created a new spatial registration Activity Find Studies, Series and Instances See Error! Reference source not found., section Activity Get Studies, Series and Instances See Error! Reference source not found., section , restricted to Study Root Query/Retrieve Information Model GET and to all SCP Storage SOP Classes and SOP Class UIDs as listed in Table Activity Save Fusion Description and Sequencing of Activities The user created a spatial registration Proposed Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg Spatial Registration See Table 4-2 for the SOP Class / Transfer Syntax mapping Table 4-16: Fusion Application proposed Presentation Contexts Save Fusion SCU None SOP Specific Conformance The Fusion Application provides standard conformance to the DICOM Storage SOP Classes. July 1, 2014 Document Revision 2 Page 29 of 89

30 4.2.6 SmartBrush Application Specification The SmartBrush Application allows the user to create, read and update segmentations based on DICOM image data SOP Classes and Transfer Syntaxes The SmartBrush Application accepts the following SOP Classes: SOP Class Name SOP Class UID SCU SCP Volumetric Images CT Image No Yes Enhanced CT Image No Yes Enhanced MR Image No Yes MR Image No Yes Multi Frame Grayscale Byte SC Image No Yes Multi Frame Grayscale Word SC Image No Yes Multi Frame Single Bit SC Image No Yes Multi Frame True Color SC Image No Yes NM Image No Yes NM Image Retired No Yes PET Image No Yes X-Ray 3D Angiographic Image No Yes X-Ray 3D Craniofacial Image No Yes Volumetric Other Segmentation Storage Yes Yes Spatial Registration No Yes Other Encapsulated PDF Storage Yes Yes Grayscale Softcopy Presentation State No Yes Key Object Selection Document No Yes Query/Retrieve Study Root Query/Retrieve Information Model FIND Yes No Study Root Query/Retrieve Information Model GET Yes No Table 4-17: SmartBrush Application supported SOP Classes Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> Smartbrush Current possible versions are: <version> = 2.0 Page 30 of 89 Document Revision 2 July 1, 2014

31 Association Initiation Policy The SmartBrush Application initiates an association in these cases: Find Studies, Series and Instances Initiated to find related studies, series and instances Get Studies, Series and Instances Initiated to retrieve related studies, series and instances Save Segmentation: The user created a new or updated an existing segmentation and/or creates a volumetric report Activity Find Studies, Series and Instances See Error! Reference source not found., section Activity Get Studies, Series and Instances See Error! Reference source not found., section , restricted to Study Root Query/Retrieve Information Model GET and to all SCP Storage SOP Classes and SOP Class UIDs as listed in Table Activity Save Segmentation Description and Sequencing of Activities New instances will be created if the user draws new or updates existing objects in an image set. Will be stored as Segmentation. creates a volumetric report. Will be stored as Encapsulated PDF Proposed Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg Segmentation Storage See Table 4-2 for the SOP Class / Transfer Encapsulated PDF Storage Syntax mapping Table 4-18: SmartBrush Application proposed Presentation Contexts Save Segmentation SCU None SOP Specific Conformance The SmartBrush Application provides standard conformance to the DICOM Storage SOP Classes. July 1, 2014 Document Revision 2 Page 31 of 89

32 4.2.7 Brain Metastases Application Specification The Brain Metastases application provides optimized planning and display for cranial multimetastases radiation planning. It requests DICOM image, Segmentation and Registration instances from the DICOM Proxy. It creates DICOM RT Structure Set, RT Plan and RT Dose instances and sends these along the image instances to a defined target system SOP Classes and Transfer Syntaxes The Brain Metastases Application accepts the following SOP Classes: SOP Class Name SOP Class UID SCU SCP Storage CT Image Yes Yes MR Image No Yes PET Image No Yes Volumetric Other Segmentation Storage No Yes Spatial Registration No Yes RT Dose Yes No RT Plan Yes No RT Structure Set Yes No Query/Retrieve Study Root Query/Retrieve Information Model FIND Yes No Study Root Query/Retrieve Information Model GET Yes No Table 4-19: Brain Metastases Application supported SOP Classes Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> BrainMets1.0 Current possible versions are: <version> = Association Initiation Policy The Brain Metastases Application initiates an association in these cases: Find Studies, Series and Instances Initiated to find related studies, series and instances Get Studies, Series and Instances Initiated to retrieve related studies, series and instances Page 32 of 89 Document Revision 2 July 1, 2014

33 Save Instances The user created a new radiotherapy treatment plan Activity Find Studies, Series and Instances See Error! Reference source not found., section Activity Get Studies, Series and Instances See Error! Reference source not found., section , restricted to Study Root Query/Retrieve Information Model GET and to all SCP Storage SOP Classes and SOP Class UIDs as listed in Table Activity Save Instances Description and Sequencing of Activities After creating a radiotherapy treatment plan the user requests storage of this plan Proposed Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg All SCU Storage SOP Classes and SOP Class UIDs as listed in Table 4-19 See Table 4-2 for the SOP Class / Transfer Syntax mapping SCU None Table 4-20: Brain Metastases Application proposed Presentation Contexts Save Instances SOP Specific Conformance The Brain Metastases Application provides standard conformance to the DICOM Storage SOP Classes. July 1, 2014 Document Revision 2 Page 33 of 89

34 4.2.8 Dose Review Application Specification The Dose Review application contains features for review of isodose lines, review of DVHs, dose comparison and summation. It requests DICOM image, Registration, RT Structure Set, RT Plan and RT Dose instances from the DICOM Proxy. It does not create any new DICOM instances SOP Classes and Transfer Syntaxes The Brain Metastases Application accepts the following SOP Classes: SOP Class Name SOP Class UID SCU SCP Storage CT Image Yes Yes MR Image No Yes PET Image No Yes Volumetric Other Spatial Registration No Yes RT Dose No Yes RT Plan No Yes RT Structure Set No Yes Query/Retrieve Study Root Query/Retrieve Information Model FIND Yes No Study Root Query/Retrieve Information Model GET Yes No Table 4-21: Dose Review Application supported SOP Classes Association Policies Implementation Identifying Information The implementation information for this Application Entity is: Implementation Class UID Implementation Version Name <version> DoseReview1.0 Current possible versions are: <version> = Association Initiation Policy The Brain Metastases Application initiates an association in these cases: Find Studies, Series and Instances Initiated to find related studies, series and instances Get Studies, Series and Instances Initiated to retrieve related studies, series and instances Activity Find Studies, Series and Instances See Error! Reference source not found., section Page 34 of 89 Document Revision 2 July 1, 2014

DICOM Conformance Statement Surgery Document Revision 4 August 26, Copyright Brainlab AG

DICOM Conformance Statement Surgery Document Revision 4 August 26, Copyright Brainlab AG Document Revision 4 August 26, 2014 2014 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab system. This system dependent from purchased licenses and

More information

DICOM Conformance Statement RT Elements Document Revision 3 January 19, Copyright Brainlab AG

DICOM Conformance Statement RT Elements Document Revision 3 January 19, Copyright Brainlab AG Document Revision 3 January 19, 2017 2017 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab Radiotherapy system. This system dependent from purchased

More information

DICOM Conformance Statement RT Elements Document Revision 5 December 14, Copyright Brainlab AG

DICOM Conformance Statement RT Elements Document Revision 5 December 14, Copyright Brainlab AG Document Revision 5 December 14, 2018 2018 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab Radiotherapy system. This system dependent from purchased

More information

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement Document Revision 1 November 17, 2009 2009 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software

More information

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement 2.1 Document Revision 2 April 13, 2011 2011 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software.

More information

Digital Lightbox 1.0

Digital Lightbox 1.0 Technical Publication DICOM Conformance Statement 1.0 Document Revision 1 June 3, 2008 2008 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software.

More information

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG Technical Publication DICOM Conformance Statement Document Revision 11 May 18, 2017 2017 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software

More information

Image Display DICOM Conformance Statement EasyViz 7.2

Image Display DICOM Conformance Statement EasyViz 7.2 Image Display DICOM Conformance Statement EasyViz 7.2 April 11, 2016 Document ID: 2016.04.035 Prepared By: Karos Health Table Of Contents 1. Document History... 5 2. Conformance Statement Overview... 6

More information

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

Version 9 DICOM Conformance Statement. Version 3.05, September 2015 Version 9 DICOM Conformance Statement Version 3.05, September 2015 1 Conformance Statement Overview The application described in this conformance statement, VEPRO EMR Manager PACS, is a collection of processes

More information

Image Display DICOM Conformance Statement

Image Display DICOM Conformance Statement Image Display DICOM Conformance Statement EasyViz 7.5 Version 1.3 February 21, 2018 Document ID: 2017.03.006 Karos Health Incorporated 7 Father David Bauer Drive Suite 201 Waterloo, ON N2L 0A2 Canada info@karoshealth.com

More information

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5 ClearCanvas Workstation DICOM Conformance Statement Document Version: 1.5 Product Name(s): Release: ClearCanvas Workstation 2.0 SP1 Date: February 22, 2010 1 CONFORMANCE STATEMENT OVERVIEW 1.1 OVERVIEW

More information

ClearCanvas Workstation DICOM Conformance Statement

ClearCanvas Workstation DICOM Conformance Statement ClearCanvas Workstation DICOM Conformance Statement Document Version: 2.1 Product Name(s): Component Name(s): Edition(s): ClearCanvas RIS/PACS ClearCanvas Workstation Chiropractic Version: 3.7 Date: July

More information

POP-Net Essential DICOM Conformance Statement

POP-Net Essential DICOM Conformance Statement POP-Net Essential DICOM Conformance Statement Revision 4.0 Software Version 4.0 and after Date: February 9, 2005 Prepared for Page 1 Copyright 2000-2005 EBM Technologies, Inc. Head office Japan office

More information

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0 Technical Publication DICOM CONFORMANCE STATEMENT BrainLAB PatientBrowser 1.0 Revision 1.0 BrainLAB AG last change: 21.02.01 11:57 Page 1 of 12 Table of contents DICOM Conformance Statement 0. INTRODUCTION...

More information

Visage. DICOM Conformance Statement

Visage. DICOM Conformance Statement Visage 7 DICOM Conformance Statement Information about manufacturer and distribution contacts as well as regulatory status of the product can be found in the User Manual. Some of the specifications described

More information

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010 Technical Publication DICOM Conformance Statement 3.0 Document Revision 2 October 5 th, 2010 2010 Copyright BrainLAB AG October 6, 2010 Document Revision 1 Page 1 of 23 1 Conformance Statement Overview

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001480.1 Page 1 of 79 AGFA HEALTHCARE DICOM Conformance Statement 2014.1 Document No. 001480.1 Revision: 1.0 When printed, this is NOT a controlled copy. HE/001480.1 Page 2 of 79 Document Information

More information

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009 Version 7 DICOM Conformance Statement Document Version 3.02, June 2009 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of

More information

DICOM Conformance Statement Quentry Version 2.0 March 7, Copyright Brainlab AG

DICOM Conformance Statement Quentry Version 2.0 March 7, Copyright Brainlab AG Version 2.0 March 7, 2018 2011-2018 Copyright Brainlab AG 1 Table of Contents 1 Table of Contents 3 2 Introduction 5 2.1 Audience... 5 2.2 Remarks... 5 2.3 Abbreviations... 5 2.4 References... 6 3 Networking

More information

Technical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement Document Revision 1 March 5, 2009 2009 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software

More information

DICOM 3.0 Conformance Statement

DICOM 3.0 Conformance Statement applies to Version 1.11 DICOM 3.0 Conformance Statement 1 Conformance Statement Overview SOP Classes Query and Retrieve Study Root Query/Retrieve Information Model Find Study Root Query/Retrieve Information

More information

MediPlus TM PACS&RIS Version 2.6

MediPlus TM PACS&RIS Version 2.6 Revision 2.0, Publication #7143-202 MediPlus TM PACS&RIS Version 2.6 DICOM 3.0 Conformance Statement June 2007 Revision 2.0, Publication #7143-202 MediPlus PACS&RIS V2.6 DICOM Conformance Statement Revision

More information

ClearCanvas Workstation DICOM Conformance Statement

ClearCanvas Workstation DICOM Conformance Statement ClearCanvas Workstation DICOM Conformance Statement Document Version: 3.7 Product Name(s): Component Name(s): Edition(s): ClearCanvas RIS/PACS ClearCanvas Workstation Personal Version: 13.1 Date: February

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001391 Page 1 of 51 AGFA HEALTHCARE DICOM Conformance Statement IMPAX EE Server version 2.17.0 PR01 When printed, this is NOT a controlled document. HE/001391 Page 2 of 51 Document Information Service-related

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001304 Page 1 of 49 AGFA HEALTHCARE DICOM Conformance Statement IMPAX Data Center 2.0 Document No. 001304 Revision: 1.1 When printed, this is NOT a controlled copy HE/001304 Page 2 of 49 Document Information

More information

Conformance Statements for DICOM PaCentric Connect / Traveler

Conformance Statements for DICOM PaCentric Connect / Traveler for DICOM Connect / Traveler Role Name / Title Signature / Date Author Svein Fimreite 21 Dec 2009 Approved Torbjørn Ånestad E-signature given by label date Document Type Engineering (ENG) Please note:

More information

Caseaccess 1.0 DICOM Conformance Statement

Caseaccess 1.0 DICOM Conformance Statement Caseaccess 1.0 DICOM Conformance Statement 1 Introduction 1.1 Integration and Features The integration of medical devices may require functions that are beyond the scope of the DICOM standard. Consequently,

More information

Punctual Dicom Workstation

Punctual Dicom Workstation DICOM Conformance Statement Punctual Dicom Workstation Company Name Product Name Product Version 2.0 Document number 2008-1001 Date June 1, 2009 Punctual Software Inc. Punctual Dicom Workstation TABLE

More information

1 CONFORMANCE STATEMENT OVERVIEW

1 CONFORMANCE STATEMENT OVERVIEW PMOD Technologies Ltd PMOD v3.9 Version 1.0 Date: 2017.11.02 1 CONFORMANCE STATEMENT OVERVIEW This document is a DICOM Conformance statement for PMOD application version 3.9xx, where xx denotes the build

More information

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F DICOM Conformance Statement ***** FDR-1000AWS CR-IR363AWS for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage (Standard) August, 2010

More information

C-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS Conformance Statement

C-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS Conformance Statement C-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS 3.0-2015 Conformance Statement Company Name: Centre of Development for Advanced Computing Product Name: C-DAC s Medical Informatics

More information

Inobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x

Inobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x Inobitec DICOM Server (PACS) Conformance Statement Version: 1.4.x Table of Contents Preface...3 1. Overview...4 2. Introduction...6 2.1 Revision History...6 2.2 Audience...6 2.3 Definitions...6 2.4 References...6

More information

iconnect Cloud Gateway V. 1.2

iconnect Cloud Gateway V. 1.2 iconnect Cloud Gateway V. 1.2 DICOM CONFORMANCE STATEMENT Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA Copyright 2017 Merge Healthcare Incorporated, an IBM Company. The content of this

More information

Health Engine DICOM Conformance Statement. Internal document number: Date:

Health Engine DICOM Conformance Statement. Internal document number: Date: Health Engine DICOM Conformance Statement Version: 1.1 Rev A Internal document number: 31011232509 Date: 20160603 the i-engineers AG June 2016 Abstract Manufacturer Support This document provides information

More information

AVIA (Dx MM) DICOM 3.0 Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) is a product of Medasys Digital Systems. Table of Contents 1INTRODUCTION... 4 1.1SCOPE AND AUDIENCE... 4 1.2REFERENCES... 4 1.3ACRONYMS AND ABBREVIATIONS...

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement for (Epic BP) Version 2.2.0 and later Document N. DCS2006001, Rev. 1 20 October 2006 2006 Marco Grampa - All rights reserved Page 1 1. OVERVIEW Epic Burn&Print (Epic BP) is

More information

DICOM Conformance Statement. Forum

DICOM Conformance Statement. Forum Document Number: CG-LEH-MS-065 Revision: 2.0 Date: 2009-07-23 Author: Tobias Kurzke DICOM Conformance Statement Forum Version 2.0 Carl Zeiss Surgical GmbH Carl-Zeiss-Str. 22 73447 Oberkochen Germany www.meditec.zeiss.com

More information

DICOM Conformance Statement FORUM

DICOM Conformance Statement FORUM Document Number: CG-LEH-MS-203 Revision: 1.0 Date: 2010-04-21 DICOM Conformance Statement FORUM Version 2.5 Carl Zeiss Surgical GmbH Carl-Zeiss-Str. 22 73447 Oberkochen Germany www.meditec.zeiss.com Document:

More information

Perennity AccessBox DICOM Conformance Statement

Perennity AccessBox DICOM Conformance Statement Perennity AccessBox DICOM Conformance Statement Version: 3.00 Perennity AccessBox Page 1 of 17 DICOM conformance 3.00 1. Table of contents 1. Table of contents 2 2. Preface 3 3. Perennity DICOM server

More information

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions StellarPACS DICOM Conformance Statement Version 1.3, August 2008 SoftTeam Solutions www.softteam.com Table of Contents 1 INTRODUCTION... 3 1.1 REFERENCE... 3 1.2 DEFINITIONS... 3 1.3 ACRONYMS, ABBREVIATIONS

More information

Perennity DICOM edition DICOM Conformance Statement

Perennity DICOM edition DICOM Conformance Statement Perennity DICOM edition DICOM Conformance Statement Version: 4.50 Perennity DICOM edition Page 1 of 18 DICOM conformance 4.50 1. Table of contents 1. Table of contents 2 2. Preface 3 3. Introduction 4

More information

DICOM Conformance Statement. CharruaPACS

DICOM Conformance Statement. CharruaPACS CharruaPACS _en Version: 2.0 Reviewed by: Rafael Sanguinetti Approved by: Rafael Sanguinetti Date: 06/25/2014 Date: 06/25/2014 Page 1 of 14 CharruaPACS CharruaPACS _en Version 2.0 Page 2 of 14 Table of

More information

Sep, th Edition 897N101668H

Sep, th Edition 897N101668H DICOM Conformance Statement Console Advance DR-ID 300CL/700CL 800CL/900CL for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage DICOM Dose

More information

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS PACSMail DICOM Conformance Statement Version 1.05 January 2009 Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS Telephone: 01223 421996 Web: www.sybermedica.com Email: info@sybermedica.com

More information

Acuo VNA. DICOM Conformance Statement Version 6.0 March 2018

Acuo VNA. DICOM Conformance Statement Version 6.0 March 2018 Acuo VNA DICOM Conformance Statement Version 6.0 March 2018 Table of Contents 1 Introduction...3 1.1 AcuoMed and its Conformance to DICOM...3 1.2 AcuoMed Features...3 2 Implementation Model...4 2.1 Application

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT Document No.: S517-1087 Revision: B DAR-7500 DICOM CONFORMANCE STATEMENT MEDICAL SYSTEMS DIVISION Revision History History Date Revision Description 1 st Edition July 2007 - A July.2008 Entirely recreated.

More information

DICOM Conformance Statement

DICOM Conformance Statement RADIOLOGY WORKFLOW SOLUTIONS DICOM Conformance Statement V3.11.0, 2015-10-05 Copyright 2015 medavis GmbH. All rights reserved. Software version: 3.11.0 For feedback or questions please contact: medavis

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement Page 1 of 77 AGFA HEALTHCARE DICOM Conformance Statement IMPAX 6.4 Solution Document No. 001264 Revision: 1.1 When printed, this is NOT a controlled document. Page 2 of 77 Document Information Service-related

More information

DICOM Conformance Statement FORUM

DICOM Conformance Statement FORUM DICOM Conformance Statement FORUM Version 2.6 Carl Zeiss Meditec AG Goeschwitzerstraße 51-52 07745 Jena Germany www.meditec.zeiss.com Document: CG-LEH-MS-254-DICOM Conformance Statement 2.6.doc Page 1

More information

efx Software DICONDE Conformance Statement

efx Software DICONDE Conformance Statement efx Software DICONDE Conformance Statement Version 1.2 9/29/2015 North Star Imaging, Inc. 1 DICOM conformance statement overview The North Star Imaging s efx Software is an imaging viewing software with

More information

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED Company Name: Vital Images Product Name: Vitrea Enterprise Suite V6.3 DICOM Conformance Statement Internal Document Number: VLC-07154Rev B Date: 25/04/2012 COPYRIGHT 1997-2012 VITAL IMAGES, INC ALL RIGHTS

More information

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED STaR DICOM Conformance Statement September 2009 Version 1.8.6 ETIAM NO COPIES PERMITTED ETIAM / DICOM STaR Version 1.8.6 DICOM Conformance Statement September 2009 Table 1: Revision History Date Version

More information

DICOM Conformance Statement iconnect Access v5.0

DICOM Conformance Statement iconnect Access v5.0 DICOM Conformance Statement iconnect Access v5.0 Copyright 2014 by Merge Healthcare Incorporated Unauthorized use, reproduction, or disclosure is prohibited. This document has been prepared by Merge Healthcare

More information

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd.

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd. InstaPACS / InstaRISPACS / InstaViewer (v3.0.22 Release) DICOM Conformance Statement Meddiff Technologies Pvt. Ltd. Table of Contents 1. Introduction... 3 1.1 Scope and Field of Application:... 3 1.2 References

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Vitrea Connection 7.1 April 16, 2018 Vital Images Incorporated 5850 Opus Parkway Suite 300 Minnetonka, MN USA 55343 support@vitalimages.com Vital Images shall not be liable

More information

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4 NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet CONFORM TO ORIGINAL Revision

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement McKesson Cardiology Release 13.2.1 June 2016 Doc ID DCM-10018 Doc Revision 1.0 Produced in Cork, Ireland Revision History Revision Revision Date Summary of Changes Rev. 1.0

More information

DICOM Conformance Statement

DICOM Conformance Statement 10.01.80.01 Rev. 03 Customer Information Bulletin Title DICOM Conformance Statement Scope Rogan View Pro-X Target Group Service Engineers Page 2 of 2 CIB 10.01.80.01 Rev. 03 How To Contact Rogan-Delft

More information

NumaStore 1.0 DICOM 3.0 Conformance Statement

NumaStore 1.0 DICOM 3.0 Conformance Statement External Distribution Revision 2 February 19, 2001 NumaStore 1.0 Revision 2 Date February 19, 2001 Author Bill Kilgore, George Panousis Revision History Revision Date By Comment 1 January 13, 2001 Bill

More information

VM PACS DICOM Conformance Statement

VM PACS DICOM Conformance Statement VM PACS DICOM Conformance Statement Visual Medica 06/06/2014 1 Content 1. INTRODUCTION... 4 1.1. Conformance Statement Overview... 4 1.2. Field of Application... 5 1.3. References and Definitions... 6

More information

Carl Zeiss Meditec AG

Carl Zeiss Meditec AG OPMI PENTERO 900 Software Releases 1.0, 1.1, 1.2 and 1.3 OPMI PENTERO 800 Software Releases 1.2 and 1.3 DICOM GE-30-1870-en Version 1.3 MMN: EN_30_200_0029I 1 Networking 4 1.1 Introduction 4 1.2 Implementation

More information

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED Company Name: Vital Images Product Name: Vitrea Advanced Visualization 7.5 DICOM Conformance Statement Internal Document Number: VLC-09529 Rev A Date: March, 2017 COPYRIGHT 1997-2017 VITAL IMAGES, INC

More information

Software Version 6.0 DICOM Conformance Statement

Software Version 6.0 DICOM Conformance Statement Software Version 6.0 DICOM Conformance Statement Related Products: PowerServer, Gateway, Gateway Router, PowerCache, RapidResults ReadFromAnywhere.com All Information provided in this document and in the

More information

Mirada XD DICOM Conformance Statement

Mirada XD DICOM Conformance Statement Mirada XD DICOM Conformance Statement mm1050-3 1 Conformance Statement Overview Mirada XD implements the necessary DICOM services to read DICOM images and other objects from the file system and save secondary

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement VioArchive 2.7 September 28, 2017 Vital Images Incorporated 5850 Opus Parkway Suite 300 Minnetonka, MN USA 55343 support@vitalimages.com Vital Images shall not be liable for

More information

DICOM Conformance Statement

DICOM Conformance Statement Rev. 10.10 DICOM Conformance Statement CPS10M10DCS005BS rev. 5 date : 14-12-2015 (d.m.y) MediMatic S.r.l. Viale Cembrano 4C 16148 Genova ITALY Notice MediMatic shall not be liable for errors contained

More information

Documento n Revision 1.5 Dicom Conformance Statement del sistema PACS di AGFA

Documento n Revision 1.5 Dicom Conformance Statement del sistema PACS di AGFA Allegato 1A.B AZIENDA U.L.S.S. N. 20 DI VERONA FORNITURA DI UN ANGIOGRAFO FINALIZZATO ALLA RIVASCOLARIZZAZIONE POLIDISTRETTUALE - MULTIDISCIPLINARE CON ALLEGATO CAPITOLATO TECNICO PROCEDURA APERTA Documento

More information

DICOM Conformance Statement

DICOM Conformance Statement Date: 2017 10 02 DICOM Conformance Statement VideoStation Version 3.50 Softneta K. Barsausko str. 59 LT-51423 Kaunas Lithuania Page 1 of 38 1 Conformance Statement Overview VideoStation is an image acquisition

More information

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL

More information

Carl Zeiss Meditec AG

Carl Zeiss Meditec AG OPMI PENTERO 900 Software Releases 1.0 and 1.1 GE-30-1870-en Version 1.1 1 Networking 4 1.1 Introduction 4 1.2 Implementation Model 4 1.2.1 Application Data Flow Diagram 5 1.2.2 Functional Definitions

More information

SYNAPSE 3D Conformance Statement FUJIFILM SYNAPSE 3D V3.0. Conformance Statement. Revision Z45N

SYNAPSE 3D Conformance Statement FUJIFILM SYNAPSE 3D V3.0. Conformance Statement. Revision Z45N FUJIFILM SYNAPSE 3D V3.0 Conformance Statement Revision 1.0.0 1 Revision History SYNAPSE 3D Conformance Statement Revision Date Description 1.0 2011/07/01 Initial revision. 2 Table of Contents 1 Introduction...4

More information

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications DOC1987748 Revision 1 DoseWatch 2.2 Copyright 2017 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK CONFORMANCE STATEMENT OVERVIEW DoseWatch

More information

Patterson DICOM Imaging. DICOM Conformance Statement

Patterson DICOM Imaging. DICOM Conformance Statement Patterson DICOM Imaging DICOM Conformance Statement Notice The software described in this document has been validated in accordance with the governing DICOM standard at the time of this document's release.

More information

Mirada XD DICOM Conformance Statement

Mirada XD DICOM Conformance Statement Mirada XD DICOM Conformance Statement mm1050-4 1 Conformance Statement Overview Mirada XD implements the necessary DICOM services to read DICOM images and other objects from the file system and save secondary

More information

DICOM. Conformance Statement EPIQ 7 and 5 Release 1.8.x Affiniti 70, 50 and 30 Release 1.8.x Rev A 24 April 2017

DICOM. Conformance Statement EPIQ 7 and 5 Release 1.8.x Affiniti 70, 50 and 30 Release 1.8.x Rev A 24 April 2017 Koninklijke Philips Electronics N.V. 2017 All rights are reserved. DICOM Conformance Statement EPIQ 7 and 5 Release 1.8.x Affiniti 70, 50 and 30 Release 1.8.x 000590000000098 Rev A 24 April 2017 0.1 Revision

More information

DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0

DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0 DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0 Document Version: 1.5 (April 4, 2008) Linkverse S.r.l. Linkverse S.r.l. Viale della Piramide Cestia 1/B 00153 Roma P.IVA/CF 09836921008

More information

Medical Imaging Consultants, Inc.

Medical Imaging Consultants, Inc. IA2000 Conformance Statement 1 Medical Imaging Consultants, Inc. Conformance Statement IA2000 Document: MICI-210-01 Revision: 6.0 Document Status: Approved When printed, this is NOT a controlled copy Reviewers

More information

JiveX Web-enabled solutions for medical imagecommunication

JiveX Web-enabled solutions for medical imagecommunication JiveX Web-enabled solutions for medical imagecommunication and processing JiveX Mammo Screening Manager Conformance Statement - DICOM Version: 4.5.3 As of 2012-12-17 VISUS Technology Transfer GmbH Universitätsstr.

More information

NumaLink-3.0 DICOM 3.0 Conformance Statement

NumaLink-3.0 DICOM 3.0 Conformance Statement External Distribution Revision 3 October 5, 2001 NumaLink-3.0 Revision 3 Date October 5, 2001 Author Bill Kilgore Revision History Revision Date By Comment 1 July 2, 2001 Bill Kilgore First draft 2 July

More information

ImageBroker 4.1. DICOM Conformance Statement V 1.0. As of Copyright medigration GmbH All rights reserved

ImageBroker 4.1. DICOM Conformance Statement V 1.0. As of Copyright medigration GmbH All rights reserved ImageBroker 4.1 DICOM Conformance Statement V 1.0 As of 17.07.2009 Copyright medigration GmbH All rights reserved medigration GmbH, Schuhstr. 30, 91052 Erlangen Tel: +49 (0) 9131/69087-40, Fax: +49 (0)

More information

Carl Zeiss Surgical GmbH

Carl Zeiss Surgical GmbH OPMI Pentero MediLive MindStream Software Release 2.2 GE-30-1712-en Version 1.0 Copyright Carl Zeiss Surgical GmbH, Germany 2007 All rights reserved 1 Networking 4 1.1 Introduction 4 1.2 Implementation

More information

DICOM V3.0 Conformance Statement. SenoIris 1SP2

DICOM V3.0 Conformance Statement. SenoIris 1SP2 DICOM V3.0 Conformance Statement SenoIris 1SP2 Image Diagnost International Reproduction of this document without prior written approval is prohibited. Image Diagnost International reserves the right to

More information

SecurView RT/TechMate Workstation DiCom Conformance statement

SecurView RT/TechMate Workstation DiCom Conformance statement breast imaging solutions DICOM Standard Interface SecurView RT/TechMate Workstation DiCom Conformance statement Software Version 8.4 man-03818 revision 002 SecurView RT/TechMate 8.4 Workstation DICOM

More information

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement CoActiv EXAM-PACS DICOM Conformance Statement Page 1 of 40 0. COVER PAGE CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement The information contained in this document is subject

More information

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics DICOM Conformance Statement isite PACS 4.1 CREF4.09-80 2011 Nov 23 Philips Healthcare Informatics isite PACS 4.1 CREF4.09-80 2011 Nov 23 Philips Healthcare is part of Royal Philips Electronics www.medical.philips.com

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001128 Page 1 of 43 AGFA HEALTHCARE DICOM Conformance Statement IMPAX ES Release 5.2.x & 5.3.x Document No. 001128 Revision: 1.4 When printed, this is NOT a controlled copy HE/001128 Page 2 of 43 26

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Philips IntelliSpace Portal V8.0 Koninklijke Philips N.V. 2016 All rights are reserved. ICAP-T-030001.09b Corresponds to ICAP-W-030001.02 Issued by: Philips Medical Systems

More information

ETIAM Nexus. DICOM Conformance Statement.

ETIAM Nexus. DICOM Conformance Statement. ETIAM Nexus DICOM Conformance Statement www.etiam.com Product Version: 5.42 Date: June 2015 ETIAM Head Office in Europe : ETIAM S.A.S.U. 2, rue du Pierre-Joseph Colin 35000 Rennes France Phone : +33.(0)2.99.14.33.88

More information

DICOM Conformance Statement. Version: 2.X

DICOM Conformance Statement. Version: 2.X dcm4chee DICOM Conformance Statement Version: 2.X Eng. Marco Bortolozzo, A-thon s.r.l. www.a-thon.it 2 Table of Contents Preface... 6 1 Overview... 7 2 Introduction... 10 2.1 Revision History... 10 2.2

More information

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0 DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM TM MODEL SSA-640A V5.0 TOSHIBA MEDICAL SYSTEMS CORPORATION 2015 ALL RIGHTS RESERVED Trademarks Viamo is a trademark of Toshiba Medical Systems

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement TOPCON Corporation TOPCON SPECULAR MICROSCOPE SP-1P Version 1.10 Document Version: 1 Date: 2014-02-17 1 CONFORMANCE STATEMENT OVERVIEW This document declares conformance to

More information

dicom PACS 5 Version 5.2

dicom PACS 5 Version 5.2 dicompacs 5 Version 5.2 TABLE OF CONTENTS 1. Introduction... 3 1.1. Revision History... 3 1.2. Abbreviations and Acronyms... 4 2. Implementation Model... 5 2.1. Application Data Flow Diagram... 5 2.2.

More information

McKesson Radiology EXP1

McKesson Radiology EXP1 McKesson Radiology 12.1.1 EXP1 DICOM CONFORMANCE STATEMENT McKesson Technology Solutions 130 10711 Cambie Road, Richmond, BC, Canada V6X 3G5 Telephone: 604.279.5422 Toll-Free: 1-800-661-5885 Fax: 1.800.261.5432

More information

DICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG

DICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG Document Revision 3 July 6, 2016 2016 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software ExacTrac. The DICOM import part of the application

More information

Carl Zeiss Surgical GmbH

Carl Zeiss Surgical GmbH OPMI Pentero MediLive MindStream Software Release 2.1 GE-30-1612-en Version 1.2 Copyright Carl Zeiss Surgical GmbH, Germany 2006 All rights reserved 1 Networking 4 1.1 Introduction 4 1.2 Implementation

More information

DICOM Conformance Statement. Xcelera R4.1 L1SP1

DICOM Conformance Statement. Xcelera R4.1 L1SP1 DICOM Conformance Statement Xcelera R4.1 L1SP1 Koninklijke Philips Electronics N.V. 2014 All rights are reserved. Document Number: ICAP-PF.0011649 Issued by: Philips Healthcare P.O. Box 10.000 5680 DA

More information

DICOM Conformance Statement Product Name HCP DICOM Net Version

DICOM Conformance Statement Product Name HCP DICOM Net Version Title DICOM Conformance Statement Product Name HCP DICOM Net Version 5.00.00 Copyright - 2000-2013 SoftLink International Pvt. Ltd. SoftLink International Pvt. Ltd. Page 1 of 37 2, Anand Park, Aundh, Pune

More information

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B DxMM/DxWin DICOM 3.0 Conformance Statement Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B Table of Contents (Table des Matières) 1 Introduction 6 1.1 Scope and Audience 6 1.2 References

More information

Visbion Limited. Image Viewer 4.1 Dicom Conformance Statement DCS-IV-Iss1. Issue 1 21 March Commercial in Confidence

Visbion Limited. Image Viewer 4.1 Dicom Conformance Statement DCS-IV-Iss1. Issue 1 21 March Commercial in Confidence Visbion Limited Image Viewer 4.1 Dicom Conformance Statement DCS-IV-Iss1 Issue 1 21 March 2013 Commercial in Confidence Visbion Limited Visbion House, Gogmore Lane, Chertsey, KT16 9AP, United Kingdom Tel:

More information