Evaluator Guide. Site Recovery Manager 1.0

Size: px
Start display at page:

Download "Evaluator Guide. Site Recovery Manager 1.0"

Transcription

1 Evaluator Guide Site Recovery Manager 1.0

2 Site Recovery Manager Evaluator Guide VMware, Inc. All rights reserved. Protected by one or more of U.S. Patent Nos. 6,397,242, 6,496,847, 6,704,925, 6,711,672, 6,725,289, 6,735,601, 6,785,886, 6,789,156, 6,795,966, 6,880,022, 6,944,699, 6,961,806, 6,961,941, 7,069,413, 7,082,598, 7,089,377, 7,111,086, 7,111,145, 7,117,481, 7,149,843, 7,155,558, 7,222,221, 7,260,815, 7,260,820, 7,269,683, 7,275,136, 7,277,998, 7,277,999, 7,278,030, 7,281,102, and 7,290,253; patents pending. VMware, the VMware boxes logo and design, Virtual SMP and VMotion are registered trademarks or trademarks of VMware, Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. VMware, Inc Hillview Ave. Palo Alto, CA VMware, Inc.

3 CONTENTS About This SRM 1.0 Evaluator Guide SRM Quick Start Checklist SRM Evaluation Checklist Chapter 1: Overview of VMware Site Recovery Manager (SRM) Chapter 2: Planning for BC/DR when using VMware SRM Chapter 3: SRM Workflow setup at the Protected and Recovery sites Chapter 4: Using SRM to run a Test against a Recovery Plan Chapter 5: Using SRM to failover the Protected Site to the Recovery Site Chapter 6: Failback from the Recovery Site to the Protected Site Chapter 7: SRM Alarms and Site Status Monitoring Chapter 8: SRM Roles and Privileges Conclusion 3 VMware, Inc.

4 Site Recovery Manager Evaluator Guide About This Evaluator Guide Intended Audience The Site Recovery Manager (SRM Evaluator Guide is intended to provide the SRM customers and evaluators with a guide that will walk them through the SRM workflow that has to be completed to allow for the successful and automated service failover from the designated SRM protected site to the designated SRM recovery site. This guide will also provide an overview which includes the considerations and guidance to execute a failback of services from the recovery site back to the site that was originally designated as the SRM protected site. To successfully use this SRM Evaluator Guide the following is assumed: ESX Server or ESX 3.5 has been installed on physical servers in the SRM protected and recovery sites. An instance of VirtualCenter 2.5 exists in each of the SRM protected and recovery sites. A multisite SAN infrastructure is in place, and setup to replicate designated VMFS datastores between the SRM protected and recovery sites. The virtual machines (VMs) that have been selected to be protected VMs for the SRM evaluation have been moved onto the designated replicated datastores. VMs that have not been selected to be protected VMs for the evaluation should be moved to non replicated datastores. If you are running ESX 3.5, Storage VMotion could be used to complete the move with zero downtime. Referring to the SRM Installation and Administration Guide for details complete the following: The basic installation of Site Recovery Manager on the SRM or VirtualCenter servers in the SRM protected and recovery sites has been completed. A SRM license is installed on the VirtualCenter license server at the protected and recovery sites. The installation of the SRM plug-in has been completed and the SRM plug-in has been enabled on the Virtual Infrastructure Client instances that will be used to access the SRM protected and recovery sites. VMware Infrastructure Documentation If you need additional information on VMware Virtual Infrastructure, consult the VMware Infrastructure documentation, which consists of the combined VMware VirtualCenter and ESX Server documentation set. Documentation is available from: 4 VMware, Inc.

5 Disaster Recovery (DR), Virtual Infrastructure (VI) and SRM abbreviations Used in this Guide The following DR, VI and SRM abbreviations are used throughout this evaluator guide: Abbreviation BC/DR SRM VC VI Client VM RP VMFS SAN Description Business Continuity and Disaster Recovery Site Recovery Manager VirtualCenter Virtual Infrastructure Client used to access Virtual Center and SRM Virtual machines on a managed host Virtual Infrastructure Resource Pool Virtual Machine File System Storage area network type datastore shared between managed hosts Disaster Recovery (DR) and SRM Terminology Used in this Guide The following DR and SRM terminology is used throughout this evaluator guide: DR and SRM Terminology array-based replication logical unit number (LUN) Failover Failback datastore Host SRM Server protected VM un-protected VM protected site recovery site datastore group protection group Storage Replication Adapter (SRA) shadow VM inventory mappings recovery plan Description Replication of virtual machines that is managed and executed by the storage subsystem itself rather than from inside the virtual machines, the vmkernel or the Service Console. Refers to a single SCSI storage device on the SAN that can be mapped to one or more ESX Servers. Event that occurs when the recovery site takes over operation in place of the protected site after the declaration of a disaster. Reversal of failover, returning IT operations to the primary site. Storage for the managed host VirtualCenter managed hosts Manages and monitors the SRM recovery plans A VM that is protected by SRM because it is located on a replicated datastore A VM that is not protected by SRM because it is located on a non replicated datastore The site that contains the protected VMs The site that contains the replicated protected VMs from the protected site Replicated datastores containing complete sets of protected VM A group of VMs that will be failed over together to the recovery site during test or recovery Enables SRM to interact with a storage array An artifact in the recovery site VC inventory that represents a protected VM from the protected site VC Associations between protected resource pools VM folders, networks and their destination counterparts at the recovery site Contains the complete set of steps needed to recover (or test recovery of) the protected VMs in one or more protection groups Document Feedback VMware welcomes your suggestions for improving our documentation. If you have comments, send your feedback to: docfeedback@vmware.com. 5 VMware, Inc.

6 Site Recovery Manager Evaluator Guide Technical Support and Education Resources The following sections describe the technical support resources available to you. Online Support for the Site Recovery Manager Technical support is available through the Support Request (SR) system. Go to and click on Create Support Request. Please note that you will need a valid VMware account in order to open a SR. If you do not already have an account, you will need to register for one here. Support Offerings Find out how VMware support offerings can help meet your business needs, go to VMware Education Services VMware courses offer extensive hands on labs, case study examples, and course materials designed to be used as on the job reference tools. For more information about VMware Education Services, go to 6 VMware, Inc.

7 SRM Quick Start Checklist Before starting to work through the SRM installation and configuration workflows that are outlined in this SRM Evaluator guide, we recommend you refer to the SRM Storage Release notes that are specific for the SRM supported storage platform that you will be using in your protected and recovery site and work through the checklist to ensure your storage platforms are ready for integration with SRM. Once you have worked through the appropriate storage checklist you should then proceed to work through the SRM Pre- Install checklist below which when completed will ensure you are ready to proceed with the setup SRM. SRM Pre-Install Checklist Site Description Yes / No Using your VMware Store Account access the URL below to download the SRM software, Storage Replication Adapter, and other relevant product and program information: Protected SQL Enterprise 2005 or Oracle Database server setup and ready for use. Protected A database instance has been created for Virtual Center Protected A database user created with db owner and create table privileges Protected A system DSN created for the VC database Protected Virtual Center 2.5 server installed and ready for use. Protected Protected Protected Protected Protected Protected Recovery Recovery Recovery Recovery Recovery Recovery Recovery Recovery Recovery Recovery Recovery The ability to access the Virtual Center 2.5 server via the VI Client At least one ESX Server or ESX Server 3.5 installed and integrated into Virtual Center, with access to a LUN on a SAN that has been configured as a VMFS datastore and setup for data replication to a corresponding SAN in the recovery site. A database instance has been created for Site Recovery Manager (SRM) A database user created with db owner and create table privileges A system DSN created for the SRM database Identify a system (physical or virtual) to install the SRM software and the Storage Replication Adapter (SRA) for your respective array SQL Enterprise 2005 or Oracle Database server setup and ready for use. A database instance has been created for Virtual Center A database user created with db owner and create table privileges A system DSN created for the VC database Virtual Center 2.5 server installed and ready for use. The ability to access the Virtual Center 2.5 server via the VI Client At least on ESX Server or ESX Server 3.5 installed and integrated into Virtual Center, with access to a LUN on a SAN that has been configured as a VMFS datastore and setup for data replication to a corresponding SAN in the recovery site. A database instance has been created for Site Recovery Manager (SRM) A database user created with db owner and create table privileges A system DSN created for the SRM database Identify a system (physical or virtual) to install the SRM software and the Storage Replication Adapter (SRA) for your respective array 7 VMware, Inc.

8 Site Recovery Manager Evaluator Guide SRM Evaluation Checklist To aid you with your SRM evaluation please refer to the SRM Evaluation Checklist below which provides a high level summary of the various SRM workflows and configuration tasks that should be completed during your SRM Evaluation. SRM Evaluation Checklist Site Description Yes / No Protected Connection: This involves pairing the VirtualCenter servers at the protected and recovery sites. CH 3 - Pg 15 Protected Array Managers: SRM leverages array based replication between a protected site and a recovery site. When working through the Array Manager configuration wizard SRM will identify which arrays are available including the datastores groups that have been setup for replication between the protected and recovery site. CH 3 - Pg16 Protected Inventory Preferences: Using the Inventory Mapper wizard, the protected VMs now need to be mapped to the Networks, Compute Resources and Virtual Machine Folders that are available at the recovery site. CH 3 - Pg 19 Protected Protection Groups: A protection group is a group of VMs that will be failed over together to the recovery site.work through the Protection Groups configuration wizard to complete the Protection Group setup. CH 3 - Pg 20 Recovery Recovery Plan. A recovery plan describes the steps necessary to recover the protected VMs in one or more protection groups. These steps can be predefined (e.g. Power On VM) or user-defined callouts. When a recovery plan is defined, the basic steps necessary to recover the protection groups it contains are automatically generated. CH 3-25 Protected IP Address Network Customization to allow protected VMs to start with the correct IP addresses and network configuration in the recovery site. CH - 3 Pg 25 Note: This task may not be required for protected VMs that use DHCP to obtain an IP address or in environments that have a Stretched VLAN network topology. Recovery Test your Recovery Plan via the SRM TEST Recovery Plan option. CH 4 Recovery Run your Recovery Plan via the SRM RUN Recovery Plan option. CH 5 Recovery Protected Protected Recovery Protected Recovery Note: SRM does not support an automated push one button failback via the SRM User Interface. A failback to the original protected site is possible and is documented in CH 6 should you want to resync the data in the recovery site back to the protected site. Failback (Optional). Refer to CH 6 for the failback procedure which will involve you working closely with your storage team to complete failback. SRM Alarms and Site Monitoring. Enable the appropriate notifications and alarms to stay in compliance with your documented monitoring policies. CH 7 SRM Roles and Privileges. Assign the appropriate SRM Roles to stay in compliance with your documented security policies. CH 8 8 VMware, Inc.

9 Chapter 1: Overview of VMware Site Recovery Manager (SRM) VMware Site Recovery Manager(SRM) provides business continuity and disaster recovery protection for virtual environments. Protection can extend from individual replicated datastores to an entire virtual site. VMware s virtualization of the data center offers advantages that can be applied to business continuity and disaster recovery: The entire state of a virtual machine (memory, disk images, I/O and device state) is encapsulated. Encapsulation enables the state of a virtual machine to be saved to a file. Saving the state of a virtual machine to a file allows the transfer of an entire virtual machine to another host. Hardware independence eliminates the need for a complete replication of hardware at the recovery site. Hardware running ESX at one site can provide business continuity and disaster recovery protection for hardware running ESX at another site. This eliminates the cost of purchasing and maintaining a system that sits idle until disaster strikes. Hardware independence allows an image of the system at the protected site to boot from disk at the recovery site in minutes or hours instead of days. SRM leverages array based replication between a protected site and a recovery site. The workflow that is built into SRM automatically discovers which datastores are setup for replication between the protected and recovery sites. SRM can be configured to support bi-directional protection between two sites. SRM provides protection for the operating systems and applications encapsulated by the virtual machines running on ESX. A SRM server must be installed at the protected site and at the recovery site. The protected and recovery sites must each be managed by their own VirtualCenter Server. The SRM server uses the extensibility of the VirtualCenter Server to provide: Access control Authorization Custom events Event-triggered alarms Site Recovery Manager Prerequisites SRM has the following prerequisites: A VirtualCenter server installed at the protected site. A VirtualCenter server installed at the recovery site. Pre-configured array-based replication between the protected site and the recovery site. Network configuration that allows TCP connectivity between SRM servers and VC servers An Oracle or SQL Server database that uses ODBC for connectivity in the protected site and in the recovery site. A SRM license installed on the VC license server at the protected site and the recovery site. 9 VMware, Inc.

10 Site Recovery Manager Evaluator Guide Site Recovery Manager Configuration and Protection Setup and configuration are accomplished by following workflows for the protected and recovery sites. SRM is installed as a plugin into a Virtual Infrastructure Client (VI Client). SRM uses the VI Client as the User Interface (UI). The SRM UI is accessed by clicking on the Site Recovery icon in the VI client toolbar and is used for the setup of the SRM workflows, recovey plan testing as well as services failover from the protected site to the recovery site. It is important to complete the worklows in the order they are presented in this guide. The recovery site configuration workflow involves the following activities: The user installs the SRM server. The user installs the SRM plugin into the VI Client The protection site configuration workflow involves the following activities: The user installs the SRM server. If a different VI Client is used to access the protected and recovery sites, the user installs the SRM plugin into the VI Client, otherwise this activity can be skipped. Security certificates are established between the SRM servers and the VC servers. The user pairs the SRM servers at the protected and recovery sites. SRM identifies available arrays and replicated datastores and determines the datastore groups. The protection site protection workflow involves the following activities: Using the Inventory Mapper, the user maps the networks, compute resources and virtual machine folders in the protected site to their counterparts in the recovery site. The user creates protection groups from the datastores discovered by SRM. For each protected VM, the user can override default values. The recovery site protection workflow involves the following activities: The user creates the recovery plan. SRM creates the recovery plan steps. Optionally the user has the ability to customize the recovery plan Failover and Testing SRM automates many of the tasks required at failover. With the push of one button, SRM: will power down the protected VMs if there is connectivity between sites and they are online. suspend data replication and Read/Write enable the replica datastores. rescan the ESX servers at the recovery site. registers the replicated protected VMs. shuts down non-essential VMs at the recovery site if required to free up resources for the protected VMs being failed over. completes power-up of replicated protected VMs in accordance with the recovery plan. 10 VMware, Inc.

11 SRM does not require production system downtime to run tests. This means you can test often to ensure that you are protected in case of a disaster. For testing, SRM: creates a test environment that includes network and storage infrastructure that is isolated from the production environment. rescans the ESX servers. registers the replicated VMs. completes power-up of protected VMs in the order specified during creation of the disaster recovery plan. provides a report of test results. resets everything in preparation for a disaster or next scheduled SRM Test. 11 VMware, Inc.

12 Site Recovery Manager Evaluator Guide Chapter 2: Planning for BC/DR when using VMware SRM This chapter will provide an overview of the site planning and preparation that should be completed to ensure the SRM protected and recovery sites are prepared for the SRM Evaluation. Figure 2.1 Figure 2.1 represents a SRM protected site which contains local services and protected services. The local services are infrastructure type services (Active Directory, Print services, Virus Management services and Security Camera services) and are generally bound to the data center. The protected services are application type services, and these are the services that need to be made available to the business at time of test or disaster. This will be accomplished using SRM. Using the SRM protected site depicted in Figure 2.1 we will now review the planning and preparations that should be completed to ensure both the SRM protected and recovery sites are ready for a successful SRM deployment. Site planning and preparation at the protected site involves the following: Identify which VMs will be designated as protected VMs. o app_vm1 through app_vm12 Identify which VMs will be designated as un-protected VMs o ad_server, print_server, security_camera_server and virus_mgt_server Determine the number of datastore groups that will be required to hold the protected VMs. o Based on the 12 VMs we have designated to be protected VMs and for the purposes of the SRM configuration that will be depicted in this evaluator guide we will require 2 datastore groups which will contain six complete VMs per datastore group. 12 VMware, Inc.

13 If existing datastores will be used for the protected VMs, identify which datastores need to be configured as datastore groups otherwise provision the required number of new datastores to host the protected VMs. Working with your SAN team ensure all the datastores that will host protected VMs are configured as datastore groups i.e. setup for replication between the protected and recovery site. o Referring to Figure 2.2, we will require 2 datastore groups, shared-san-1 and sharedsan-2, which were previously configured to allow for the replication of data to the recovery site. Note: The setup and configuration of SAN replication will differ from array vendor to array vendor, if you are unsure of how to complete the necessary replication setup and configuration, consult with your array vendor who should be in a position to provide you with all the necessary information. Move all the designated protected VMs onto the SRM datastore groups. Storage VMotion can be used to complete the relocation of the protected VMs with zero service downtime. If possible ensure there are only protected VMs on the datastores that are being replicated from the protected site to the recovery site. Referring to Figure 2.2 which is a VMware topology map view, it is clear to see that: o app_vm1 through app_vm6 are hosted from datastore group shared-san-1 o app_vm7 through app_vm12 are hosted from datastore group shared-san-2 o The non replicated infrastructure VMs are hosted from datastore vim22-storage1 Figure VMware, Inc.

14 Site Recovery Manager Evaluator Guide Figure 2.2 represents a different view of the same SRM protected site depicted in Figure 2.1 which contains local services being hosted from datastore vim22-storage1 and the protected services hosted from datastore groups shared-san-1 and shared-san-2 respectively. The protected services are under the control of SRM and will be made available at time of test or disaster via SRM at the recovery site. Figure 2.3 Figure 2.3 represents a SRM recovery site which contains local services and will also service the failed over protected services which are all the protected VMs hosted from datastore groups shared-san-1 and shared-san-2 in the SRM protected site depicted in Figure 2.2. Once again the local services are infrastructure type services (Active Directory, Print services, Virus Management services and Security Camera services) that are bound to the recovery site data center. 14 VMware, Inc.

15 Chapter 3: SRM Workflow setup at the Protected and Recovery sites This chapter will provide an overview of the SRM workflows that have to be completed to ensure SRM is providing BC/DR services for the designated virtual machines at time of test or during an actual event that necessitated the declaration of a disaster. Figure 3.1 The SRM workflows that will be outlined below will be associated with the virtual data centers vim22dc and vim23dc depicted in Figures 2.1, 2.2 and 2.3. Figure 3.1 shows part of the VI Client window, the Site Recovery icon has been highlighted as well as the Setup pane. The protected site SRM workflows will be completed via the VI Client by selecting Configure and working through the configuration wizard for each of the steps identified below: Connection: This involves pairing the VirtualCenter servers at the protected and recovery sites. The VC server in the local data center vim22dc is dr-vc-vim22.eng.vmware.com. The VC server in the remote data center vim23dc is dr-vc-vim23.eng.vmware.com. 15 VMware, Inc.

16 Site Recovery Manager Evaluator Guide Figure 3.2 Once the remote VC servers information has been entered you will be presented with the following Connect to Remote Site window. Figure 3.3 Once reciprocity has been established, click Close to complete the setup. You are now ready to move onto the Array Manager configuration step. Note: If you are using certificates that are not properly signed, the last two check marks in Figure 3.3 may appear as yellow warning triangles when Reciprocity is established. The use of certificates that are not properly signed will not prevent you from moving onto the next SRM configuration step which involves configuring the Array Managers. Array Managers: SRM leverages array based replication between a protected site and a recovery site. When working through the Array Manager configuration wizard SRM will identify which arrays are available including the datastores groups that have been setup for replication between the protected and recovery site. 16 VMware, Inc.

17 Virtual machines reside on VMFS datastores which are created on LUNs that reside on the storage arrays. SRM uses the term "datastore group" as a way of identifying a replicated datastore(s) that protect virtual machines. If SRM detects a virtual machine spanning more than one datastore (i.e VM has two virtual disks one on each datastore) then to allow that whole VM to be failed over the SRM datastore group *must* contain both datastores and SRM will enforce this, we will cover this further below. In SRM a datastore group is the basic unit of replication. SRM PROTECTED SITE - STORAGE ARRAY Datastore Group 1 Datastore Group 2 VM 2 Disk VM 2.vmx VM 4. vmx VM 4 Disk VM 1. vmx VM 1 Disk VM 3.vmx VM 3 Disk VM 5.vmx VM 5 Disk VMFS Datastore A VMFS Datastore B VMFS Datastore C VMFS Datastore DE Replicated LUN A Non Replicated LUN B Replicated LUN C Replicated LUN D Replicated LUN E VM 1 is Protected by SRM VM 2 is not Protected by SRM VM 3, VM 4 and VM 5 are Protected by SRM Figure 3.4 In Figure 3.4, VM1 is contained in Replicated LUN A (Datastore Group 1) so VM1 is a protected VM. VM2 is contained on a non replicated LUN and therefore VM2 is not protected by SRM. Datastore Group 2 consists of Datastore C and Datastore DE which contains protected VMs 3, 4, and 5. It is worth noting that even though VM4 spans two datastores, it is completely contained within Datastore Group 2 and as a result is fully protected by SRM. In SRM an entire VM needs to be located within a datastore group which has a one to one mapping to a protection group. Datastore groups are automatically discovered by SRM, a datastore group is defined by the configuration of the virtual machines selected for protection by SRM. SRM protection groups will be covered at a later stage in this guide. It is worth noting at this time that VMware is actively working with our storage partners who are responsible for the development of their own Storage Replication Adapaters (SRAs), which will enable their storage arrays to integrate with SRM. For this reason VMware anticipates the list of storage Manager Types to become more extensive over time as the storage partners complete work on their respective SRAs. 17 VMware, Inc.

18 Site Recovery Manager Evaluator Guide If you do not see a Manager Type for a storage array which you have in your environment that you wish to integrate with SRM, VMware strongly urges you to follow-up directly with the storage vendor in question to enquire about the availability of their SRM storage replication adapter as VMware is not in a position to comment on the availability of products currently under development by our partners, in this case our storage partners. Working through the Array Manager configuration wizard will take you to the Add Array Manager window depicted in Figure 3.5, select the correct Manager Type for the SAN in your environment. Figure 3.5 Once you have selected the correct Manager Type from the drop down box, complete the entry of all the appropriate information within the Array Manager Information section and click Connect to start the SRM Discover Storage Array process which will run for several minutes. The Array Manager configuration wizard will walk you through the configuration for the Protection Side Array Managers and Recovery Side Array Managers. Figure 3.6 is a consolidated view of the three Configure Array Managers windows to shows an example of the information that will be presented at the end of the SRM Discover Storage Array process for the protected and recovery sites. The information shown below is for the Virtual Data Centers vim22dc and vim23dc. At this stage you are now ready to move onto the Inventory Preferences configuration step. 18 VMware, Inc.

19 Figure 3.6 Inventory Preferences: Using the Inventory Mapper wizard, the protected VMs now need to be mapped to the Networks, Compute Resources and Virtual Machine Folders that are available at the recovery site. The mappings are completed via the Inventory Preferences pane below by clicking on the respective Primary Site Resources catergory and clicking on Edit and working through the inventory mapper wizard for the respective resource catergory. 19 VMware, Inc.

20 Site Recovery Manager Evaluator Guide Figure 3.7 In Figure 3.7 the Inventory Preferences pane shows the configured Inventory Preferences for the protected VMs in the virtual data center vim22dc and how they are mapped to the appropriate resources in the virtual data center vim23dc which is the designated recovery site. Protection Groups: A protection group is a group of VMs that will be failed over together to the recovery site. A protection group is associated with a single datastore group. A datastore group could contain a single datastore or multiple datasotres as illustrated in Figure 3.4. Working through the Protection Groups configuration wizard you will get to the window shown in Figure 3.8. During the creation of the Protection Groups, SRM requires a location to store some temporary VirtualCenter inventory files for the protected VMs. SRM will present the available datastores at the recovery site that could be selected for the storing of these temporary files. It is preferable and suggested that you select a non replicated datastore for these temporary files at the recovery site. Figure VMware, Inc.

21 Select the datastore that will store the temporary virtual machine files and click Next which will take you to the next Create Protection Group window shown in Figure 3.9. You will now be presented with the list of all the protected VMs that will be assigned to the Protection Group currently being created. Figure 3.9 Figure 3.9 shows the six protected VMs assigned to the first protection group called Protection Group 1 which was created in the virtual data center vim22dc. 21 VMware, Inc.

22 Site Recovery Manager Evaluator Guide Figure 3.10 Figure 3.10 shows the six protected VMs assigned to the second protection group called Protection Group 2 which was created in the virtual data center vim22dc. The creation of the protection groups completes the SRM workflow activities for the protected site. To recap we have worked through the following SRM workflow activities so far: Connection: This involved the pairing the VirtualCenter servers at the protected and recovery sites. Array Managers: SRM leverages array based replication between a protected site and a recovery site. The integration of array based replication with SRM is achieved by selecting the correct Manager Type for the SAN in your protected and recovery sites. Inventory Preferences: Using the Inventory Mapper, the protected VMs are mapped to the Networks, Compute Resources and Virtual Machine Folders that are available at the recovery site. Protection Groups: A protection group is a group of VMs that will be failed over together to the recovery site. The creation of a protection group results in VC inventory updates in the recovery site. 22 VMware, Inc.

23 Figure 3.11 shows the view of the recovery site virtual data center vim23dc, it is worth noting that once the protection groups were created, the virtual infrastructure inventory in the recovery site was automatically updated with new inventory objects. The first new inventory object is the nested resource pool called recovery under the top level RP called shared. The remaining inventory objects that have been added are the protected VMs from the SRM protected site. Figure 3.11 The remaining workflow activity which is the creation the SRM Recovery Plan and any subsequent customizations to the recovery plan are completed via the VI Client connecting to the VC server in the designated recovery site The recovery site protection workflow involves the following activities: Building a Recovery Plan. A recovery plan describes the steps necessary to recover the protected VMs in one or more protection groups. These steps can be predefined (e.g. Power On VM) or user-defined callouts. When a recovery plan is defined, the basic steps necessary to recover the protection groups it contains are automatically generated. These steps can then be customized by you by re-ordering existing steps or adding new steps and callouts. When a Recovery Plan is created for one or more protection groups, the plan is automatically populated with the basic steps needed to failover the protected VMs to the recovery site. 23 VMware, Inc.

24 Site Recovery Manager Evaluator Guide Figure 3.12 shows the recovery steps from a SRM recovery plan called Recovery Plan 2 Protection Group 2 required to complete a partial site failover for the local data center vim22dc which is protected by SRM. The protected VMs that will be failed over are app_vm7 through to app_vm12 from Protection Group 2 which is associated to the datastore group shared-san-2. Figure VMware, Inc.

25 In Figure 3.13 the VI Client lists three Recovery Plans that were created by working through the Recovery Plan wizard. To create a new Recovery Plan, click on the Add button on the toolbar or Add Recovery Plan under the Commands section and work through the Recovery Plan wizard. Figure 3.13 The following section will illustrate one of the supported ways to customize settings associated with a protected VM. By working through the steps that follow you will be able to customize the network configuration settings for a protected VM which will allow the protected VM to start up at the recovery site after an actual failover with an IP address that is correct for the network in the recovery site. Referring to Figure 3.14, working from the VI Client that is connected to the recovery site complete the following. From the Edit menu option, click on Customization Specifications and work through the wizard that follows. Figure 3.14 A Customization Specification Manager window opens up, click on New, and complete the information being requested by the wizard. Ensure you select the correct Target Virtual Machine OS and provide a name for virtual machine customization profile in the Customization Specification Information as shown in Figure VMware, Inc.

26 Site Recovery Manager Evaluator Guide Figure 3.15 Click Next to continue to the window below which is depicted by Figure Figure VMware, Inc.

27 At this point it worth noting that the only information that will be applied to the protected VM you wish to customize via SRM will be Network information. For the SRM 1.0 release you may need to provide information for all the virtual machine properties highlighted in Figure 3.16 by the two red boxes to allow you to move onto the next virtual machine property screen as the Next button will only become active once you enter text into the property field currently being displayed to you. Figure 3.17 When you get to the Network properties section as depicted in Figure 3.17, please be sure to click on the Custom Settings radio button, and then click on the Next button to proceed to the Network Custom Settings window shown in Figure Figure VMware, Inc.

28 Site Recovery Manager Evaluator Guide Referring to Figure 3.18, highlight the NIC 1 and click on the Customize button which will take you to the standard Network Properties window below which is shown in Figure Complete entering all the relevant network configuration information you wish to assign to the protected VM when it is started in the recovery site and click OK. Figure 3.19 Complete working through the Customization Specifications wizard which will bring you to the Customization Specification Manager window depicted in Figure Figure 3.20 The steps that follow outline how to apply the network customization profile to a protected VM, in this case app_vm12 which is completed via the VI Client that is connecting to the protected site. Select the protection group that contains the virtual machine you wish to customize. In this case we want to customize app_vm12 which is associated to Protection Group 2 as indicated by Figure Click on Configure Protection which will launch the Recovery Launch wizard. 28 VMware, Inc.

29 Figure 3.21 Working through the Recovery Launch wizard, you will get to the Virtual Machine Customization Window that is shown in Figure From the drop down box select the virtual machine customization profile you wish to assign the protected VM, in this case customization_appvm12, and click Next to proceed onto the last two remaining customizations which are Before Power On and After Power On which will conclude Customization Specifications wizard. Figure VMware, Inc.

30 Site Recovery Manager Evaluator Guide Once the Customization Specifications wizard closes you will be taken back to the VI Client view depicted in Figure Under the Recent Tasks pane you should see an entry which will serve as confirmation that the customization profile customization_appvm12 was successfully applied o app_vm12. The protected VM app_vm12 has now been customized and will start up with the network configuration information assigned to the customization profile customization_appvm12. Figure VMware, Inc.

31 Chapter 4: Using SRM to run a Test against a Recovery Plan This chapter will provide an overview of how SRM enables you to Test a recovery plan by simulating a failover of virtual machines from the protected site to the recovery site. The benefit of using SRM to run a failover simulation against a recovery plan is that it allows you to confirm that the recovery plan has been setup correctly for the protected VMs. You will be able to confirm that the protected VMs startup in the correct order, taking into account the various application service dependencies for the protected VMs in your environment. It is worth pointing out that when you select the option to Test a recovery plan via SRM, the simulated failover is executed in an isolated environment that includes network and storage infrastructure at the recovery site that is isolated from the protected site (production environment) which ensures the protected VMs at the protected site are not subject to any kind of service interruption during the testing of the recovery plan. SRM will also create a test report that can be used to demonstrate your level of preparedness to the business or individual business units whose services are being protected by SRM as well as to the auditors and compliance officers if required. The simulated failover completes by resetting the environment to be ready for the next event which could be another simulated failover, or an actual failover for a scheduled BC/DR test or in response to an event which resulted in the business declaring a disaster. Figure VMware, Inc.

32 Site Recovery Manager Evaluator Guide We will now work through a simulated failover leveraging the SRM Test a recovery plan option. In Figure 4.1 the VI Client lists the three Recovery Plans that were created by working through the Recovery Plan wizard. There are two ways to initiate the simulated failover, you can either click on the Test button in the toolbar or click on the Test Recovery Plan link under the Commands section, and both are highlighted in Figure 4.1. Before the simulated failover is started you will be presented with the dialog box (Figure 4.2) that informs you the performance of local virtual machines may be impacted if there are insufficient compute resources at the recovery site to support the local virtual machines and protected VMs. The dialog box also informs you that the replication of the datastore groups may be suspended during the simulated failover. Click Yes to start the Test of your recovery plan. Figure 4.2 While the simulated failover test is running, the status of each step that makes up the recovery plan can be monitored by going to Recovery Steps tab in the VI Client which will inform you what steps are currently Running as well as what steps were completed with a Success status. It is worth pointing out that there are some steps in a recovery plan that will only be executed during a simulated test, these steps are identified by Test Only under the Mode column, there are also some steps that will only be executed during an actual failover, these steps are identified by Recovery only under the Mode column. Figure VMware, Inc.

33 Figure 4.4 shows a partial view of the recovery site s VI Client window. SRM provides an audit trail via a report which is generated automatically at the end of each SRM Test or SRM Recovery. The reports are accessible via the History tab and can be viewed by clicking on the View link under the Actions column, which will result in a browser window opening that contains a log of the steps executed during the test, with the total time to execute the recovery plan and the time it took to execute each step in the recovery plan. Figure 4.4 The following is a recap of the highlevel tasks excecuted by SRM when performing a simulated failover via the Test a recovery plan option that is availble via SRM enabled VI Client. With the push of one button, SRM: creates a test environment that includes network and storage infrastructure that is isolated from the production environment. rescans the ESX servers. registers the replicated VMs. completes power-up of protected VMs in the order specified during creation of the disaster recovery plan. provides a report of test results. resets everything in preparation for a disaster or next scheduled SRM Test. 33 VMware, Inc.

34 Site Recovery Manager Evaluator Guide Chapter 5: Using SRM to failover the Protected Site to the Recovery Site This chapter will provide an overview of how SRM enables you to Run a recovery plan which will result in the actual failover of virtual machines from the protected site; the failover process via SRM is rapid, repeatable, reliable, manageable and auditable. Figure 5.1 We will now work through an actual failover leveraging the SRM Run a recovery plan option. In Figure 5.1 the VI Client lists the three Recovery Plans that were created by working through the Recovery Plan wizard. There are two ways to initiate the actual failover, you can either click on the Run button or click on the Execute Recovery Plan link under the Commands section, and both are highlighted in Figure 5.1. The Run Recovery Plan dialog box represented by Figure 5.2 warns you that you are about to run the a recovery plan which will result in changes to the protected virtual machines and the infrastructure of both the protected and recovery site datacenters. Click the radio button to confirm you understand the implications of running your recovery plan and then click on the Run Recovery Plan button that is highlighted in figure 5.2 to start the failover of protected VMs from the protected site to the recovery site. The Run Recovery Plan dialog box also provides a summary of the Recovery Plan Information, that includes the Recovery Plan that is going to be run, along with the names of the protected and recovery sites, the number of protected VMs that will be failed over as well as a connectivity status from the recovery site back to the protected site. 34 VMware, Inc.

35 Figure 5.2 While the failover is being executed, the status of each step that makes up the recovery plan can be monitored by going to Recovery Steps tab highlighted in Figure 5.1 of recovery site s VI Client which will inform you what steps are currently Running as well as what steps were completed with a Success status. Once again it is worth pointing out that there are some steps in a recovery plan that will only be executed during a simulated test, these steps are identified by Test Only under the Mode column, there are also some steps that will only be executed during an actual failover, these steps are identified by Recovery only under the Mode column. Once all the protected VMs have been failed over and reported to be powered, which can be confirmed in several places from within the VI Client you are now ready to start validating that all application services restarted cleanly at the recovery site, in this case we are referring to the protected VMs app_vm7 through app_vm12 from Protection Group 2 which is associated to the datastore group shared-san-2. Once you have completed the validation of the failed over application services at the recovery site you are now in a position to report the successful failover to the business and allow the respective business users to access the application services which are now being hosted out of the recovery site. Figure 5.3 shows a VMware topology map view, it is clear to see that app_vm7 through app_vm12 were successfully failed over to the recovery site and that they are being hosted from a datastore connected to a host in the recovery site. The non replicated infrastructure VMs (ad_server, print_server, security_camera_server and virus_mgt_server) are hosted from datastore vim23- storage1 in the recovery site. Note: SRM will automatically perform a re-signature of the replicated datastore in the recovery site, which means LVM.EnableResignature will be set to 1 on the ESX host/s that have access to the replicated datastores in the recovery site. The re-signature that is initiated by SRM will result in the replicated datastores being presented with a prefix of snap x- where X is a number, this is evident in Figure 5.3 which shows the replicated datastore presented as snap shared-san VMware, Inc.

36 Site Recovery Manager Evaluator Guide Figure 5.3 As pointed out in the previous chapter SRM will automatically generate a report, in this instance the report is for a SRM Run operation against the recovery plan we selected. The report is acessible via the History tab and can be viewed by clicking on the View link under the Actions column. The steps to failback services from the recovery site back to the protected site once the disaster event is over will be outlined in the next chapter of this guide. The following is a recap of the highlevel tasks excecuted by SRM when performing a failover of virtual machines from the protected site to the recovery site via the Run a recovery plan option that is availble via SRM enabled VI Client. SRM automates many of the tasks required at time of failover. With the push of one button, SRM: will power down the protected VMs if there is connectivity between sites and they are online. suspend data replication and Read/Write enable the replica datastores. rescan the ESX servers at the recovery site. registers the replicated protected VMs. shuts down non-essential VMs at the recovery site if required to free up resources for the protected VMs being failed over. completes power-up of replicated protected VMs in accordance with the recovery plan. 36 VMware, Inc.

37 Chapter 6: Failback from the Recovery Site to the Protected Site Although not included as an automated procedure in SRM 1.0 this chapter will provide an overview which includes the considerations and guidance to execute a failback of services from the recovery site back to the site that was originally designated as the protected site or to a new site due to a catastrophic disaster that has destroyed the original site. For the purpose of this SRM evaluator guide we will consider the failback scenario outlined below: Failback Scenario: Failback of application services from the recovery site back to the protected site after a scheduled BC/DR test which was conducted using SRM to perform the Recovery actual failover and not a test failover of services from the protected site to the recovery site. With this scenario we will assume the infrastructure at protected site has not changed during BC/DR test and that SRM completed a successful recovery of the protected VMs required for the BC/DR test to the recovery site. The protected VMs from the protected site that were failed over for the BC/DR test were confirmed to have been shutdown by SRM in the protected site. The business has a requirement to restore all data generated during the BC/DR test at the recovery site back to the protected site. To aid in the explanation of the failback steps that will follow we will use the abbreviations listed in the following table. Abbreviation Site A Site B PG 1 RP 1 PG 2 RP 2 PG 3 Source LUN Target LUN Clone LUN Description original protected site original recovery site original protection group that was defined at Site A original recovery plan that was defined at Site B new protection group that is defined at Site B to facilitate the failback from Site B via SRM back to Site A new recovery plan that is defined at Site A to facilitate the failback from Site B via SRM back to Site A new protection group that is defined at Site A to facilitate the failover to Site B via SRM. Note: this protection group is basically the same protection group that was defined for PG1 VMFS Datastore being replicated to alternate data center Replicated Datastore in the alternate data center This is a clone of the Target LUN, this will be used during a Test failover only Note: Failback in SRM 1.0 is a multi step procedure that for most part is a manual process; however SRM can be leveraged to provide some automation during the failback as outlined in Steps 1 through 20 below when working in conjunction with your storage team to complete the necessary storage configuration work (storage personality swap) outlined in Step 7 and Step 17. Before starting with Step 1, you will need to set the LVM.DisallowSnapshotLun = 0 on all the ESX hosts in the protected site that are zoned to the LUNs which have been assigned for SRM protected virtual machines and configured for replication between the protected and recovery site. This one time operation is required to ensure the ESX hosts in the protected site are able to access the replicated datastores after the storage personality swap has occurred. Steps 1 through 20 outline the steps that need to be completed for a successful failback from Site B to Site A as well as the steps to complete the re-protection of Site A after the failback from Site B. 37 VMware, Inc.

38 Site Recovery Manager Evaluator Guide Storage configuration after running a Recovery in SRM (Actual Failover) from Site A to Site B for datastore shared-san-2 Site A - Protected Site Site B - Recovery Site Data Replication is suspended Source LUN in Site A with Target LUN in Site B Write Disabled (read only) Read Write Enabled Protected VMs (app_vm7 to app_vm12) All powered off by SRM at start of SRM Recovery Source LUN (shared-san-2) Target LUN (shared-san-2) Protected VMs (app_vm7 to app_vm12) All powered on by SRM during the SRM Recovery Note: Datastore shared-san-1 will be in the same configuration state as shared-san-2 A Clone LUN is not used during a Recovery in SRM. Figure Ensure all users that were involved with the BC/DR test have completed their test scripts and are no longer accessing any of the protected VMs that were recovered from Site A for the BC/DR test. 2. Shutdown all of the protected VMs that were recovered to Site B for the BC/DR test. 3. Ensure you have created a list of all the Protected VMs that were recovered to Site B. 4. Perform a cleanup of the directory in Site B that contained the VM configuration files created during protection group creation in Site A (this is the location selected during the creation of the original protection group/s in Site A - Protection Group 1 and Protection Group 2, refer to Figure 3.8). Refer to Figure 6.2 for an example of the placeholder VM configuration file information that was written to vim23-storage1 during the creation of the protection groups in Site A. You can use your list you created in Step 3 above as a reference during this clean-up step. Figure VMware, Inc.

39 5. Connect to the VC instance in Site A and delete PG 1 (Protection Group 1 and Protection Group 2). Refer to Figure 6.3, a protection group can be removed by right clicking on the protection group in the right hand side Site Recovery pane. Figure Connect to the VC instance in Site A and perform a remove from inventory operation on all the protected VMs in Site A that were recovered to Site B. In Figure 6.4 all the protected VMs in Site A have been selected, by right clicking on the selected VMs you will be presented with a menu box, click on Remove from Inventory, which will then remove the all the highlighted protected VMs from the VC inventory in Site A. Figure VMware, Inc.

40 Site Recovery Manager Evaluator Guide 7. Work with your Storage team to complete a storage configuration change personality swap whereby the Source LUN is now associated with Site B and the Target LUN is associated with Site A, as depicted in Figure 6.5. Rescan the ESX servers at the protected and recovery site to ensure they become aware of the underlying storage changes. Storage configuration prior to running a Recovery in SRM from Site B to Site A (Failback) after a storage configuration change personality swap Site A - Recovery Site Site B - Protected Site Data Replication is now configured from Site B to Site A Source LUN is in Site B with Target LUN in Site A Write Disabled (read only) Read Write Enabled Protected VMs (app_vm7 to app_vm12) Protected VMs offline in Site A Target LUN (shared-san-2) Source LUN (shared-san-2) Protected VMs (app_vm7 to app_vm12) Protected VMs that will be recovered to Site A Note: A Clone LUN is not configured in Site A and will not be used during the Failback from Site B back to Site A Figure Complete the Array Manager configuration wizard from Site B. After the storage configuration work is completed in Step 7, the Source LUN is now assigned to Site B and the Target LUN is assigned to Site A as depicted in Figure 6.6. Figure VMware, Inc.

41 9. Configure the Inventory Preferences in Site B, these inventory preferences will be assigned to the protected VMs when they are restarted in Site A after the failback. Figure 6.7 shows the inventory preferences that will be mapped to the protected VMs in Site A after the failback from Site B. Figure Connect to the VC instance in Site B and configure PG 2 (Failback Protection Group 1 and Failback Protection Group 2) in Site B as depicted in Figure 6.8 for the protected VMs you wish to failback to Site A. Figure Connect to the VC instance in Site A and configure RP 2 in Site A. Note: You should not delete RP 1 (Recovery Plan 3 Complete Site Failover, refer to Figure 6.8) that was created in Site B during the initial SRM workflows that were completed to protect 41 VMware, Inc.

42 Site Recovery Manager Evaluator Guide the designated VMs in Site A. Refer to Figure 6.9 which shows RP 2 (Failback Recovery Plan 3) which was created in Site A. Figure Using SRM complete the Failback of the original protected VMs back to Site A. This is accomplished by performing a Recovery against RP 2 (Failback Recovery Plan 3) shown in Figure 6.9. Figure 6.10 depicts the storage configuration once the SRM Recovery against RP 2 completes. Storage configuration after running a Recovery in SRM (Actual Failover) from Site B to Site A for datastore shared-san-2 Site A - Recovery Site Site B - Protected Site Data Replication is suspended Source LUN in Site B with Target LUN in Site A Read Write Enabled Write Disabled (read only) Protected VMs (app_vm7 to app_vm12) All powered on by SRM during the SRM Recovery Target LUN (shared-san-2) Source LUN (shared-san-2) Protected VMs (app_vm7 to app_vm12) All powered off by SRM at start of SRM Recovery Note: A Clone LUN is not used during a Recovery in SRM (Actual Failover) in SRM. Figure VMware, Inc.

43 13. Shutdown all of the protected VMs in Site A that were failed back from Site B during the SRM Recovery operation performed in Step Perform a cleanup of the directory in Site A that contained the VM configuration files created during protection group creation in Site B (this is the location selected during the creation of PG 2 in Site B, refer to Figure 3.8). Refer to Step 4 above for guidance if required. 15. Connect to the VC instance in Site B and delete PG 2 (Failback Protection Group 1 and Failback Protection Group 2) that were created in Site B. Refer to Step 5 above for guidance if required. 16. Connect to the VC instance in Site B and perform a remove from inventory operation on all the protected VMs in Site B that were recovered to Site A, in this scenario this would be app_vm1 to app_vm12. Refer to Step 6 above for guidance if required. 17. Work with your Storage team to complete a second storage configuration change personality swap whereby the Source LUN is now re-associated with Site A, the Target LUN is re-associated with Site B along with the Clone LUN as depicted in Figure Rescan the ESX servers at the protected and recovery site to ensure they become aware of the underlying storage changes. Note: The Storage configuration has now been reverted back to the original configuration that was handed over to the Virtualization team prior to the setup of SRM and for this reason we depict the storage configuration in Figure 6.11 with the Clone LUN in Site B. The data synchronization method (snapshot at intervals or continuous synchronization) of the Target LUN to the Clone LUN is determined by the Storage Array vendor. When a simulated failover is initiated via the Test option in SRM, final data synchronization is performed from the Target LUN to the Clone LUN. Storage configuration during a SRM Test failover from Site A to Site B for datastore shared-san-2 Site A - Protected Site Site B - Recovery Site Data Replication continues between the Source LUN and Target LUN The data synchronization between the Target LUN and the Clone LUN is suspended Read Write Enabled Write Disabled (read only) Read Write Enabled Protected VMs (app_vm7 to app_vm12) Protected VMs that will be recovered to Site B Source LUN (shared-san-2) Target LUN (shared-san-2) Clone LUN (shared-san-2) Protected VMs (app_vm7 to app_vm12) Protected VMs powered on in Site B during the SRM Test failover Note: Datastore shared-san-1 will be in the same configuration state as shared-san-2 Figure Create PG 3 (Protection Groups 1 and Protection Group 2) in Site A for the protected VMs. Note: The protection groups you create here should be identical to the protection groups that were originally associated with RP 1 (Recovery Plan 3 Complete Site Failover), the recovery plan that was executed in Recovery mode that resulted in the startup of the protected VMs in Site B. 43 VMware, Inc.

44 Site Recovery Manager Evaluator Guide 19. Re-associate the protection groups created in step 19 in Site A with RP 1 (Recovery Plan 3 Complete Site Failover) in Site B. Refer to Figure 6.12 which highlights the first part of the re-association which is initiated by right clicking on Recovery Plan 3 Complete Site Failover. Working through the Edit Recovery Plan wizard you will then get to a screen that will require you to select which protection groups you wish to reassociate with the recovery plan, refer to Figure 6.13 which shows the two protection groups Protection Group 1 and Protection Group 2 that should be selected so they can be re-associated with RP1 (Recovery Plan 3 Complete Site Failover) in Site B. Note: You do not need to delete the RP 2 (Failback Recovery Plan 3) that was created in Site A to facilitate the recovery back to Site A from Site Figure 6.12 Figure Once the protection groups have been re-associated with the original recovery plan as detailed in step 19 you have now completed the re-protection of the protected VMs in Site A with SRM. It is highly recommended to that you now complete a final Test a simulated failover against RP 1 (Recovery Plan 3 Complete Site Failover) to ensure that Site A is protected and ready for any event that may necessitate a Recovery via SRM to Site B should the business deem it necessary to declare a disaster. 44 VMware, Inc.

45 Note: The SRM Failback steps 1 through 20 outlined in this Chapter did not detail the following: Site Pairing from Site B back to Site A via the SRM Connection wizard: This step is not required as SRM maintains a bi-directional relationship between the paired sites, and therefore the Connection workflow only needs to be completed once for Site A and Site B to ensure each site is aware of each VC and SRM instance in the respective sites. SRM License transfer between Site A and Site B: The SRM failback steps did not discuss the transfer of SRM licenses between Site A and Site B that should be completed to ensure you are in compliance with the SRM EULA. DNS Updates: SRM 1.0 does not provide a mechanism to update DNS. DNS updates will need to be completed by you as the virtual machines are moved between Site A and Site B with SRM and under go IP address changes to accommodate disparate networks in Site A and Site B should they not be joined by Stretched VLANs. Figure 6.14 shows a summary view of the SRM configuration of Site A which has now been reverted back to the original protected site. In addition to the two protection groups Protection Group 1 and Protection Group 2 which are associated with the recovery plan Recovery Plan 3 Complete Site Failover in the designated recovery site Site B, we also have the recovery plan Failback Recovery Plan 3 listed which was used to enable the failback procedure outlined in this chapter. Figure VMware, Inc.

46 Site Recovery Manager Evaluator Guide SRM Failback Checklist To aid with Failback after a SRM Recovery please refer to the SRM Failback Checklist below which provides a high level summary of Failback steps 1 through 20 which are detailed in this chapter. Step # Site Description Yes / No 1 Site B Protected VMs recovered to Site B are no longer being used and can be powered down 2 Site B Power down the Protected VMs in Site B 3 Site B Create a list of all the Protected VMs that were recovered to Site B 4 Site B Perform a cleanup of the directory in Site B that contained the VM configuration files created during protection group creation in Site A 5 Site A Connect to the VC instance in Site A and delete PG 1 6 Site A Connect to the VC instance in Site A and perform a remove from inventory operation on all the protected VMs in Site A that were recovered to Site B 7 Storage Work Work with your Storage team to complete a storage configuration change personality swap whereby the Source LUN is now associated with Site B and the Target LUN is associated with Site A. Refer to Figure 6.5. Rescan the ESX servers at the protected and recovery site to ensure they become aware of the underlying storage changes. 8 Site B Complete the Array Manager configuration wizard in Site B which now has the Source LUN configured in Site B and the Target LUN configured in Site A 9 Site B Configure the Inventory Preferences in Site B, these inventory preferences will be assigned to the protected VMs when they are restarted in Site A after the failback 10 Site B Connect to the VC instance in Site B and configure PG 2 11 Site A Connect to the VC instance in Site A and configure RP 2 in Site A 12 Site A Using SRM complete the failback of the original protected VMs back to Site A. This is accomplished by performing a Recovery against RP 2. Figure 6.10 depicts the storage configuration after the Recovery completes 13 Site A Shutdown all of the protected VMs in Site A that were failed back from Site B during the SRM Recovery operation performed in Step Site A Perform a cleanup of the directory in Site A that contained the VM configuration files created during protection group creation in Site B 15 Site B Connect to the VC instance in Site B and delete PG 2 that was created in Site B in step Site B Connect to the VC instance in Site B and perform a remove from inventory operation on all the protected VMs in Site B that were recovered to Site A 17 Storage Work Work with your Storage team to complete a second storage configuration change personality swap whereby the Source LUN is now re-associated with Site A, the Target LUN is re-associated with Site B along with the Clone LUN as depicted in Figure Rescan the ESX servers at the protected and recovery site to ensure they become aware of the underlying storage changes. 18 Site A Create PG 3 in Site A for the protected VMs 19 Site B Re-associate PG 3 from step 18 in Site A with RP 1 in Site B 20 Site B Complete a final Test a simulated failover against RP 1 to ensure that Site A is protected and ready for any event that may necessitate a Recovery via SRM to Site B should a disaster be declared 46 VMware, Inc.

47 Chapter 7: SRM Alarms and Site Status Monitoring This chapter will provide an overview of some of the SRM Alarms that will be generated due to certain types of failures or conditions that may occur at the protected or recovery site. Awareness of the SRM alarms is an important part of understanding how SRM works across the protected and recovery sites. During the SRM product evaluation it is recommended that where possible and without impact to your production environment, failures or conditions be created in the protected and recovery site that will result in the generation of SRM alarms. The generation of these SRM alarms will serve as validation that SRM is monitoring both the protected and recovery site correctly. Each SRM server monitors the CPU utilization, disk space, and memory consumption of the guest on which it is running, and also maintains a heartbeat with its peer SRM server. VC events are sent if any of these measures falls outside of configured bounds. SRM will support the configuration of event-triggered alarms so that you can associate a notification action with any given SRM Alarm Event. These alarms are configured via the SRM UI. SRM will support the following alarm notification actions: Send to specified address Send SNMP trap to VC trap receivers Execute specified command on VC host Please refer to Chapter 9 Alerting and Monitoring in the Administrators Guide for Site Recovery Manager which details how to setup the alarm actions listed above. Failure of either site generates events which can be associated with VC alarms. Problems with the local site (e.g. resource constraints) Problems with remote site (e.g., unable to ping remote site which may indicate a disaster) Remote site failure is reflected in the SRM Alarm Events and will not automatically trigger a recovery. This must be initiated manually. SRM will raise VC events for the following conditions: Disk Space Low CPU use exceeded limit. Memory low. Remote Site not responding. Remote Site heartbeat failed. Recovery Plan Test started, ended, succeeded, failed, or cancelled. Virtual Machine Recovery started, ended, succeeded, failed, or reports a warning. As a starting point during the SRM Evaluation we recommend you complete the Action setup for the SRM Alarm Events listed below for the protected and recovery sites. You should be able to trigger these events in your environment without impacting your production environment, with the goal being that you see first hand how SRM responds and notifies you when subjected to one of the failure events listed below. Remote Site Down Remote Site Ping Failed Replication Group Removed Recovery Plan Destroyed License Server Unreachable 47 VMware, Inc.

48 Site Recovery Manager Evaluator Guide Figure VMware, Inc.

49 As you become more familiar with SRM, it associated workflows that allow you to Test your recovery plans as well as Run your recovery plan which results in the failover of services from your protected site to your recovery site we recommend that you work through the list of SRM Alarm Events which are accessed via the Alarms tab, as depicted in Figure 7.1 and enable the appropriate notification Actions for any additional SRM Alarm Events that you deem to be important for your environment. 49 VMware, Inc.

50 Site Recovery Manager Evaluator Guide Chapter 8: SRM Roles and Privileges This chapter will provide an overview of the SRM roles and the types of SRM privileges that can be set. Authorization in SRM uses the same authorization model as VirtualCenter Server. Figure 8.1 show the default SRM roles which become available for use after the SRM plug-in has been installed and enabled for use. To access these roles click on the Administration icon in the toolbar and click on the Roles tab to see a list of all the roles that are available. These default SRM roles provide the ability to delegate control to a very granular level. Figure VMware, Inc.

51 There are two sets roles. The first set contains the roles required for the primary site user to administer protection and the SRM roles are prefixed by Protection. The second set contains the roles required for the secondary site user to administer recovery and the SRM roles are prefixed by Recovery. Protection Side SRM Roles Protection Virtual Machine Administrator: This role should be assigned on the protected Virtual Machine object in the VC inventory. It grants the associated user the ability to setup and modify the protection characteristics of the protected virtual machine. Protection SRM Administrator: This role should be assigned on the Service Instance object in the primary SRM inventory. It grants the associated user the ability to pair two sites, configure inventory mappings, and SAN arrays. Protection Groups Administrator: This role should be assigned on the Primary Configuration/Protection Service object in the SRM inventory. It grants the associated user the ability to create and modify protection profiles/groups. Recovery Side SRM Roles Recovery Inventory Administrator: This role should be assigned on the root of the VC inventory. It grants the associated user the ability to view customization specifications existing on the secondary site. Recovery Datacenter Administrator: This role should be assigned on the Datacenter object in the VC inventory where the VMs will be recovered. It grants the associated user the ability to view available datastores and perform recovery (shadow) VM customizations. Recovery Host Administrator: This role should be assigned on the Host or DRS cluster object in the VC inventory where the VM will be recovered. It grants the associated user the ability to configure VM components during recovery. Recovery Virtual Machine Administrator: This role should be assigned on the Folder and Resource Pool objects in the VC inventory where the recovery (shadow) VMs are to be placed. It grants the associated user the ability to create and add shadow VMs to the resource pool and the folder as well as the ability to reconfigure and customize the shadow VMs at runtime and during the process of recovery. Recovery SRM Administrator: This role should be assigned on the Service Instance object in the secondary SRM inventory. It grants the associated user the ability to configure SAN arrays and create protection profiles. Recovery Plans Administrator: This role should be assigned on the Secondary Configuration/Recovery Service object in the SRM inventory. It grants the associated user the ability to reconfigure protection and shadow VMs and setup and run recovery. Note: VirtualCenter already defines a Read-Only system role which can be used to grant users the ability to view the Site Recovery Manager service. In addition, the Administrator role can be used to grant user complete control over both the protection and recovery SRM components. 51 VMware, Inc.

52 Site Recovery Manager Evaluator Guide SRM also allows for the creation of custom SRM roles by allowing you to clone one of the default SRM roles and then by editing the cloned SRM role you can select which privileges should be associated to the custom SRM role that you are creating. Figure 8.2 shows a Custom SRM Role and all the privileges that can be selected to complete the creation of the SRM Custom Role. Figure VMware, Inc.

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE VMware vcenter Site Recovery Manager 4.1 EVALUATOR'S GUIDE Table of Contents. Getting Started.... 3 About VMware vcenter Site Recovery Manager.... 3 About This Guide.... 3 Intended Audience.... 3 Assumptions....

More information

Automated Disaster Recovery. Simon Caruso Senior Systems Engineer, VMware

Automated Disaster Recovery. Simon Caruso Senior Systems Engineer, VMware Automated Disaster Recovery Simon Caruso Senior Systems Engineer, VMware What is a Disaster? Complete loss of a data center for an extended period of time Declaration of a disaster usually requires consensus

More information

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Setup for Microsoft Cluster Service Revision: 041108

More information

Architecting DR Solutions with VMware Site Recovery Manager

Architecting DR Solutions with VMware Site Recovery Manager Architecting DR Solutions with VMware Site Recovery Manager Agenda Understanding components of DR Introduction to VMware Site Recovery Manager (SRM) Key SRM Concepts Business Benefits of SRM 2 DR What

More information

Virtual Disaster Recovery. Presented by: Dan Mclean ANZ Enterprise SE Manager, VMware

Virtual Disaster Recovery. Presented by: Dan Mclean ANZ Enterprise SE Manager, VMware Virtual Disaster Recovery Presented by: Dan Mclean ANZ Enterprise SE Manager, VMware What is a Disaster? Complete loss of a data center for an extended period of time Declaration of a disaster usually

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5

Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 Title: Getting Started with ESX Server 3i Embedded Revision: 20071022 Item: VMW-ENG-Q407-430 You can

More information

Basic System Administration ESX Server and Virtual Center 2.0.1

Basic System Administration ESX Server and Virtual Center 2.0.1 ESX Server 3.0.1 and Virtual Center 2.0.1 Basic System Administration Revision: 2006105 Item: VI-ENG-Q306-293 You can find the most up-to-date technical documentation on our Web site at http://www.vmware.com/support/

More information

Virtual Infrastructure Web Access Administrator s Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5

Virtual Infrastructure Web Access Administrator s Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5 Virtual Infrastructure Web Access Administrator s Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5 Virtual Infrastructure Web Access Administrator s Guide Virtual Infrastructure Web Access

More information

VMware Infrastructure 3 Primer Update 2 and later for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

VMware Infrastructure 3 Primer Update 2 and later for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Update 2 and later for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 VMware Infrastructure 3 Primer Revision: 20090313 Item: EN-000021-02 You can find the most up-to-date technical documentation

More information

Disaster Recovery of Microsoft Exchange Server 2007 on EMC Celerra iscsi using EMC Replication Manager and VMware vcenter Site Recovery Manager

Disaster Recovery of Microsoft Exchange Server 2007 on EMC Celerra iscsi using EMC Replication Manager and VMware vcenter Site Recovery Manager Disaster Recovery of Microsoft Exchange Server 2007 on EMC Celerra iscsi using EMC Replication Manager and VMware vcenter Site Recovery Manager Best Practices Planning Abstract This white paper discusses

More information

Virtual Infrastructure Web Access Administrator s Guide ESX Server 3.0 and VirtualCenter 2.0

Virtual Infrastructure Web Access Administrator s Guide ESX Server 3.0 and VirtualCenter 2.0 Virtual Infrastructure Web Access Administrator s Guide ESX Server 3.0 and VirtualCenter 2.0 Virtual Infrastructure Web Access Administrator s Guide Revision: 20060615 Item: VI-ENG-Q206-217 You can find

More information

VMware VMFS Volume Management VMware Infrastructure 3

VMware VMFS Volume Management VMware Infrastructure 3 Information Guide VMware VMFS Volume Management VMware Infrastructure 3 The VMware Virtual Machine File System (VMFS) is a powerful automated file system that simplifies storage management for virtual

More information

Configuration Maximums VMware Infrastructure 3: ESX Server 3.5 Update 2, ESX Server 3i version 3.5 Update 2, VirtualCenter 2.

Configuration Maximums VMware Infrastructure 3: ESX Server 3.5 Update 2, ESX Server 3i version 3.5 Update 2, VirtualCenter 2. Topic Configuration s VMware Infrastructure 3: ESX Server 3.5 Update 2, ESX Server 3i version 3.5 Update 2, VirtualCenter 2.5 Update 2 When you are selecting and configuring your virtual and physical equipment,

More information

VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S

VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S Implementation Guide EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com

More information

VMware vfabric Data Director Installation Guide

VMware vfabric Data Director Installation Guide VMware vfabric Data Director Installation Guide vfabric Data Director 1.0.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

NexentaStor Storage Replication Adapter User Guide

NexentaStor Storage Replication Adapter User Guide NexentaStor 5.1.1 Storage Replication Adapter User Guide Date: January, 2018 Part Number: 3000-nxs-SRA-User-Guide-5.1.1-000092-A Copyright 2018 Nexenta Systems TM, ALL RIGHTS RESERVED Notice: No part of

More information

QuickStart Guide vcenter Server Heartbeat 5.5 Update 1 EN

QuickStart Guide vcenter Server Heartbeat 5.5 Update 1 EN vcenter Server Heartbeat 5.5 Update 1 EN-000205-00 You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/ The VMware Web site also provides the

More information

VMware vfabric Data Director Installation Guide

VMware vfabric Data Director Installation Guide VMware vfabric Data Director Installation Guide vfabric Data Director 2.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by

More information

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise Virtualization with VMware ESX and VirtualCenter SMB to Enterprise This class is an intense, five-day introduction to virtualization using VMware s immensely popular Virtual Infrastructure suite including

More information

Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual

Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual Regulatory Model: E16S Series Regulatory Type: E16S001 Notes, Cautions, and Warnings NOTE:

More information

Virtual Appliance User s Guide

Virtual Appliance User s Guide Cast Iron Integration Appliance Virtual Appliance User s Guide Version 4.5 July 2009 Cast Iron Virtual Appliance User s Guide Version 4.5 July 2009 Copyright 2009 Cast Iron Systems. All rights reserved.

More information

Getting Started with ESXi Embedded

Getting Started with ESXi Embedded ESXi 4.0 Embedded vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

Business Continuity and Disaster Recovery Disaster-Proof Your Business

Business Continuity and Disaster Recovery Disaster-Proof Your Business Business Continuity and Disaster Recovery Disaster-Proof Your Business Jon Bock Senior Product Marketing Manager October 16, 2008 Agenda Disaster Recovery Requirements and Challenges Disaster Recovery

More information

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise Virtualization with VMware ESX and VirtualCenter SMB to Enterprise This class is an intense, four-day introduction to virtualization using VMware s immensely popular Virtual Infrastructure suite including

More information

SRM Evaluation Guide First Published On: Last Updated On:

SRM Evaluation Guide First Published On: Last Updated On: First Published On: 12-24-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 1.3.About This Evaluation Guide 2. Requirements 2.1.Overview 3. Evaluation Workflow

More information

ESX Server 3i Embedded Setup Guide ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5

ESX Server 3i Embedded Setup Guide ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 ESX Server 3i Embedded Setup Guide ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 ESX Server 3i Embedded Setup Guide ESX Server 3i Embedded Setup Guide Revision: 20090612 Item: VI-ENG-Q407-446

More information

vsphere Basic System Administration

vsphere Basic System Administration Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for

More information

vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 vrealize Suite 7.0

vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 vrealize Suite 7.0 vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 vrealize Suite 7.0 vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 You can find the most up-to-date technical

More information

Getting Started with VMware View View 3.1

Getting Started with VMware View View 3.1 Technical Note Getting Started with VMware View View 3.1 This guide provides an overview of how to install View Manager components and provision virtual desktops. Additional View Manager documentation

More information

Site Recovery Manager Administration. Site Recovery Manager 6.1

Site Recovery Manager Administration. Site Recovery Manager 6.1 Site Recovery Manager 6.1 You can find the most up-to-date technical documentation on the VMware Web site at: https://docs.vmware.com/ The VMware Web site also provides the latest product updates. If you

More information

vcenter CapacityIQ Installation Guide

vcenter CapacityIQ Installation Guide vcenter CapacityIQ 1.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

Site Recovery Manager Installation and Configuration. Site Recovery Manager 5.5

Site Recovery Manager Installation and Configuration. Site Recovery Manager 5.5 Site Recovery Manager Installation and Configuration Site Recovery Manager 5.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

Disaster Recovery-to-the- Cloud Best Practices

Disaster Recovery-to-the- Cloud Best Practices Disaster Recovery-to-the- Cloud Best Practices HOW TO EFFECTIVELY CONFIGURE YOUR OWN SELF-MANAGED RECOVERY PLANS AND THE REPLICATION OF CRITICAL VMWARE VIRTUAL MACHINES FROM ON-PREMISES TO A CLOUD SERVICE

More information

Site Recovery Manager Administration. Site Recovery Manager 6.0

Site Recovery Manager Administration. Site Recovery Manager 6.0 Site Recovery Manager Administration Site Recovery Manager 6.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this

More information

vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8

vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8 vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8 vrealize Suite 6.0 This document supports the version of each product listed and supports all subsequent versions until the document

More information

VMware View Upgrade Guide

VMware View Upgrade Guide View 4.0 View Manager 4.0 View Composer 2.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for

More information

Lifecycle Manager User's Guide

Lifecycle Manager User's Guide vcenter Lifecycle Manager 1.2 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

VMware vcenter AppSpeed Installation and Upgrade Guide AppSpeed 1.2

VMware vcenter AppSpeed Installation and Upgrade Guide AppSpeed 1.2 VMware vcenter AppSpeed Installation and Upgrade Guide AppSpeed 1.2 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance

Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance An Oracle Technical White Paper March 2014; v2.1 Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance Introduction... 1 Overview... 2 Prerequisites...

More information

Request Manager User's Guide

Request Manager User's Guide vcloud Request Manager 1.0.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

vsphere Upgrade Guide

vsphere Upgrade Guide ESX 4.0 ESXi 4.0 vcenter Server 4.0 vsphere Client 4.0 EN-000112-00 You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/ The VMware Web site

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the

More information

SRM 8.1 Technical Overview First Published On: Last Updated On:

SRM 8.1 Technical Overview First Published On: Last Updated On: First Published On: 12-23-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 2. Architectural Overview 2.1.Overview 3. Use Cases 3.1.Overview 3.2.Disaster

More information

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware CHAPTER 5 Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware This chapter explains setting up LMS for High Availability (HA), Live migration, and, Storage

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Storage Considerations for VMware vcloud Director. VMware vcloud Director Version 1.0

Storage Considerations for VMware vcloud Director. VMware vcloud Director Version 1.0 Storage Considerations for VMware vcloud Director Version 1.0 T e c h n i c a l W H I T E P A P E R Introduction VMware vcloud Director is a new solution that addresses the challenge of rapidly provisioning

More information

VMware vsphere with ESX 4.1 and vcenter 4.1

VMware vsphere with ESX 4.1 and vcenter 4.1 QWERTYUIOP{ Overview VMware vsphere with ESX 4.1 and vcenter 4.1 This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter.

More information

vsphere Datacenter Administration Guide

vsphere Datacenter Administration Guide vsphere Datacenter Administration Guide ESX 4.1 ESXi 4.1 vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

vsphere Basic System Administration

vsphere Basic System Administration Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for

More information

vsphere Availability Update 1 ESXi 5.0 vcenter Server 5.0 EN

vsphere Availability Update 1 ESXi 5.0 vcenter Server 5.0 EN Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

VMware vsphere Data Protection Evaluation Guide REVISED APRIL 2015

VMware vsphere Data Protection Evaluation Guide REVISED APRIL 2015 VMware vsphere Data Protection REVISED APRIL 2015 Table of Contents Introduction.... 3 Features and Benefits of vsphere Data Protection... 3 Requirements.... 4 Evaluation Workflow... 5 Overview.... 5 Evaluation

More information

ESX Server 3 Configuration Guide ESX Server 3.5 and VirtualCenter 2.5

ESX Server 3 Configuration Guide ESX Server 3.5 and VirtualCenter 2.5 ESX Server 3 Configuration Guide ESX Server 3.5 and VirtualCenter 2.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a

More information

Microsoft E xchange 2010 on VMware

Microsoft E xchange 2010 on VMware : Microsoft E xchange 2010 on VMware Availability and R ecovery Options This product is protected by U.S. and international copyright and intellectual property laws. This product is covered by one or more

More information

vsphere Availability Guide

vsphere Availability Guide Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for

More information

VMware vsphere Storage Appliance Installation and Configuration

VMware vsphere Storage Appliance Installation and Configuration VMware vsphere Storage Appliance Installation and Configuration vsphere Storage Appliance 1.0 vsphere 5.0 This document supports the version of each product listed and supports all subsequent versions

More information

SRM 6.5 Technical Overview February 26, 2018

SRM 6.5 Technical Overview February 26, 2018 February 26, 2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 2. Architectural Overview 2.1.Overview 3. Use Cases 3.1.Overview 3.2.Disaster Recovery 3.3.Disaster Avoidance 3.4.Planned

More information

What Is New in VMware vcenter Server 4 W H I T E P A P E R

What Is New in VMware vcenter Server 4 W H I T E P A P E R What Is New in VMware vcenter Server 4 W H I T E P A P E R Table of Contents What Is New in VMware vcenter Server 4....................................... 3 Centralized Control and Visibility...............................................

More information

Managing VMware vcenter Site Recovery Manager

Managing VMware vcenter Site Recovery Manager Managing VMware vcenter Site Recovery Manager This chapter contains the following sections: About VMware vcenter Site Recovery Manager, page 1 Overview of SRM Configuration, page 2 Integrating SRM with

More information

Resource Management Guide ESX Server and VirtualCenter 2.0.1

Resource Management Guide ESX Server and VirtualCenter 2.0.1 Resource Management Guide ESX Server 3.0.1 and VirtualCenter 2.0.1 Resource Management Guide Resource Management Guide Version: 2.0.1 Revision: 20060824 Item: VI-ENG-Q206-218 You can find the most up-to-date

More information

vcenter Server Installation and Setup Modified on 11 MAY 2018 VMware vsphere 6.7 vcenter Server 6.7

vcenter Server Installation and Setup Modified on 11 MAY 2018 VMware vsphere 6.7 vcenter Server 6.7 vcenter Server Installation and Setup Modified on 11 MAY 2018 VMware vsphere 6.7 vcenter Server 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Table of Contents HOL-PRT-1467

Table of Contents HOL-PRT-1467 Table of Contents Lab Overview - - Virtual Volumes with Dell EqualLogic... 2 Lab Guidance... 3 Pre-flight Instructions... 5 Module 1 - Working with Dell EqualLogic and VVOLs (60 Mins)... 11 Creating a

More information

Server Fault Protection with NetApp Data ONTAP Edge-T

Server Fault Protection with NetApp Data ONTAP Edge-T Technical Report Server Fault Protection with NetApp Data ONTAP Edge-T Jeff Whitaker, NetApp March 2013 TR-4154 TABLE OF CONTENTS 1 Introduction... 3 2 Backup and Disaster Recovery Technology... 4 2.1

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 This document supports the version of each product listed and supports all subsequent

More information

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 8.1

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 8.1 vsphere Replication for Disaster Recovery to Cloud vsphere Replication 8.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

TECHNICAL WHITE PAPER AUGUST 2017 REVIEWER S GUIDE FOR VIEW IN VMWARE HORIZON 7: INSTALLATION AND CONFIGURATION. VMware Horizon 7 version 7.

TECHNICAL WHITE PAPER AUGUST 2017 REVIEWER S GUIDE FOR VIEW IN VMWARE HORIZON 7: INSTALLATION AND CONFIGURATION. VMware Horizon 7 version 7. TECHNICAL WHITE PAPER AUGUST 2017 REVIEWER S GUIDE FOR VIEW IN VMWARE HORIZON 7: INSTALLATION AND CONFIGURATION VMware Horizon 7 version 7.x Table of Contents Introduction.... 3 JMP Next-Generation Desktop

More information

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at:

More information

Introduction to VMware Infrastructure ESX Server 3.5, ESX Server 3i version 3.5 VirtualCenter 2.5

Introduction to VMware Infrastructure ESX Server 3.5, ESX Server 3i version 3.5 VirtualCenter 2.5 Introduction to ware Infrastructure ESX Server 3.5, ESX Server 3i version 3.5 VirtualCenter 2.5 Introduction to ware Infrastructure Introduction to ware Infrastructure Revision: 20071213 Item: VI-ENG-Q407-432

More information

vsphere Virtual Machine Administration

vsphere Virtual Machine Administration ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

Storage Replication Adapter for VMware vcenter SRM. April 2017 SL10334 Version 1.5.0

Storage Replication Adapter for VMware vcenter SRM. April 2017 SL10334 Version 1.5.0 Storage Replication Adapter for VMware vcenter SRM April 2017 SL10334 Version 1.5.0 1 Introduction This lab introduces the fundamentals of VMware vcenter Site Recovery Manager on clustered Data ONTAP.

More information

Automated Disaster Recovery with Virtualization. Presented by: Phil Weiss Systems Engineer VMware New Zealand

Automated Disaster Recovery with Virtualization. Presented by: Phil Weiss Systems Engineer VMware New Zealand Automated Disaster Recovery with Virtualization Presented by: Phil Weiss Systems Engineer VMware New Zealand What is a Disaster? Complete loss of a data center for an extended period of time Declaration

More information

vcenter Server Installation and Setup Update 1 Modified on 30 OCT 2018 VMware vsphere 6.7 vcenter Server 6.7

vcenter Server Installation and Setup Update 1 Modified on 30 OCT 2018 VMware vsphere 6.7 vcenter Server 6.7 vcenter Server Installation and Setup Update 1 Modified on 30 OCT 2018 VMware vsphere 6.7 vcenter Server 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

ESX Server 3i Installable Setup Guide Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

ESX Server 3i Installable Setup Guide Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 ESX Server 3i Installable Setup Guide Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 ESX Server 3i Installable Setup Guide ESX Server 3i Installable Setup Guide Revision:

More information

Virtual Machine Backup Guide Update 2 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

Virtual Machine Backup Guide Update 2 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Virtual Machine Backup Guide Update 2 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Virtual Machine Backup Guide Virtual Machine Backup Guide Revision: 20081017 Item: EN-000036-03

More information

NexentaStor VVOL

NexentaStor VVOL NexentaStor 5.1.1 VVOL Admin Guide Date: January, 2018 Software Version: NexentaStor 5.1.1 VVOL Part Number: 3000-VVOL-5.1.1-000065-A Table of Contents Preface... 3 Intended Audience 3 References 3 Document

More information

White Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft

White Paper. A System for  Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS

More information

By the end of the class, attendees will have learned the skills, and best practices of virtualization. Attendees

By the end of the class, attendees will have learned the skills, and best practices of virtualization. Attendees Course Name Format Course Books 5-day instructor led training 735 pg Study Guide fully annotated with slide notes 244 pg Lab Guide with detailed steps for completing all labs vsphere Version Covers uses

More information

Horizon Console Administration. 13 DEC 2018 VMware Horizon 7 7.7

Horizon Console Administration. 13 DEC 2018 VMware Horizon 7 7.7 Horizon Console Administration 13 DEC 2018 VMware Horizon 7 7.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this

More information

Getting Started with ESX

Getting Started with ESX ESX 4.1 vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

VMware vcloud Director Infrastructure Resiliency Case Study

VMware vcloud Director Infrastructure Resiliency Case Study ware vcloud Director Infrastructure Resiliency Case Study ware vsphere 5.0, ware vcenter Site Recovery Manager 5.0 and ware vcloud Director 1.5 TECHNICAL WHITE PAPER v 1.0 February 2012 ware vcloud Director

More information

vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.4

vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.4 vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.4 vrealize Operations Manager Customization and Administration Guide You can find the most up-to-date technical

More information

VMware vcenter Site Recovery Manager disaster recovery best practices

VMware vcenter Site Recovery Manager disaster recovery best practices Tutorial VMware vcenter Site Recovery Manager disaster recovery best practices VMware Inc. released Site Recovery Manager (SRM) in June 2008 to provide an automated solution for failover of virtual environments

More information

Virtual Server Agent v9 with VMware. June 2011

Virtual Server Agent v9 with VMware. June 2011 Virtual Server Agent v9 with VMware June 2011 Contents Summary... 3 Backup Transport Methods... 3 Deployment Scenarios... 3 VSA Installation Requirements... 4 VSA Patch Requirements... 4 VDDK Installation...

More information

HP StorageWorks. EVA Virtualization Adapter administrator guide

HP StorageWorks. EVA Virtualization Adapter administrator guide HP StorageWorks EVA Virtualization Adapter administrator guide Part number: 5697-0177 Third edition: September 2009 Legal and notice information Copyright 2008-2009 Hewlett-Packard Development Company,

More information

Site Recovery Manager Administration. Site Recovery Manager 8.1

Site Recovery Manager Administration. Site Recovery Manager 8.1 Site Recovery Manager Administration Site Recovery Manager 8.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this

More information

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp Course Length: 2 Days Course Overview This instructor-led course covers everything the student needs to know to upgrade from VMware 3.x to

More information

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check

More information

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

TECHNICAL WHITE PAPER - FEBRUARY VMware Site Recovery for VMware Cloud on AWS Evaluation Guide TECHNICAL WHITE PAPER

TECHNICAL WHITE PAPER - FEBRUARY VMware Site Recovery for VMware Cloud on AWS Evaluation Guide TECHNICAL WHITE PAPER TECHNICAL WHITE PAPER - FEBRUARY 2019 VMware Site Recovery for VMware Cloud on AWS Evaluation Guide TECHNICAL WHITE PAPER Table of Contents Introduction 4 Pre-requisites 4 Site Recovery Manager Server...

More information

Tintri Deployment and Best Practices Guide

Tintri Deployment and Best Practices Guide TECHNICAL WHITE PAPER Tintri Deployment and Best Practices Guide for VMware vcenter Site Recovery Manager www.tintri.com Revision History Version Date Description Author 1.3 12/15/2017 Updated Bill Roth

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

VMware vcenter AppSpeed User s Guide AppSpeed 1.0 EN

VMware vcenter AppSpeed User s Guide AppSpeed 1.0 EN VMware vcenter AppSpeed User s Guide AppSpeed 1.0 EN-000213-01 VMware vcenter AppSpeed User s Guide You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/

More information

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family A step-by-step guide IBM Systems and Technology Group ISV Enablement February 2014 Copyright IBM Corporation, 2014 Table of contents

More information

VMware vcenter Configuration Manager and VMware vcenter Application Discovery Manager Integration Guide

VMware vcenter Configuration Manager and VMware vcenter Application Discovery Manager Integration Guide VMware vcenter Configuration Manager and VMware vcenter Application Discovery Manager Integration Guide vcenter Configuration Manager 5.7 vcenter Application Discovery Manager 6.2 This document supports

More information

Infrastructure Navigator User's Guide

Infrastructure Navigator User's Guide vcenter Infrastructure Navigator 1.1.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more

More information

Developing and Deploying vsphere Solutions, vservices, and ESX Agents

Developing and Deploying vsphere Solutions, vservices, and ESX Agents Developing and Deploying vsphere Solutions, vservices, and ESX Agents vsphere 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

vsphere Replication for Disaster Recovery to Cloud

vsphere Replication for Disaster Recovery to Cloud vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Disaster Recovery with Dell EqualLogic PS Series SANs and VMware vsphere Site Recovery Manager 5

Disaster Recovery with Dell EqualLogic PS Series SANs and VMware vsphere Site Recovery Manager 5 Technical Report Disaster Recovery with Dell EqualLogic PS Series SANs and VMware vsphere Site Recovery Manager 5 Abstract The virtual datacenter introduces new challenges and techniques for disaster recovery.

More information