VEVO 2100 Sole Source Specifications
|
|
- Jane Francis
- 6 years ago
- Views:
Transcription
1 VEVO 2100 Sole Source Specifications Table of Contents 1.SYSTEM Licensing for the User Safety Portability TRANSDUCERS MicroScan transducers IMAGING STATION Integrated Vevo imaging station Image-guided injection using high-frequency ultrasound ECG and respiration gating Integrated blood pressure capability Image analysis and software tools Small animal-based measurements and annotations Imaging data export and storage in multiple formats Digital RF Study management capabilities including user management mode and Time Logger Vevo LAB workstation M-Mode Anatomical M-Mode Pulse Wave (PW) Doppler Mode Power Doppler Mode Color Doppler Mode Tissue Doppler Imaging Mode D Imaging D-Mode Thresholding Contrast Imaging Software Vevo CQ Vevo Color VevoStrain TM Analysis EKV (ECG-Gated Kilohertz Visualization) ECG-Triggered - Respiration Gated Analysis Vevo Vasc Vevo Vasc Ultra TRAINING... 9 EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 1
2 VEVO 2100 Sole Source Specifications 1.SYSTEM The Vevo High-Frequency Ultrasound System is the only commercially available imaging platform that enables the researcher to obtain in vivo anatomical, functional, physiological and molecular data simultaneously, in real-time and with a resolution down to 30 µm. The system is easy to use, non-invasive and fast, providing extremely high throughput when needed. It is designed with the researcher in mind, with system presets and animal handling tools for fast image acquisition and numerous protocols, software and data management tools optimized for today s scientists. The system can also be upgraded to the Vevo LAZR photoacoustic imaging system by a hardware upgrade with Vevo LAZR imaging solution o U.S. 7,255,678 High frequency, high frame-rate ultrasound imaging system 1-1 Licensing for the User 1-2 Safety No special licensing requirements No room with shielding required With the VisualSonics ultrasound-based system, there are no radioactive substances used and unlike other imaging modalities, no dedicated room or special room shielding is required. 1-3 Portability The VSI system is portable and can be moved with ease from one room or lab to another. 2.TRANSDUCERS 2-1 MicroScan transducers Each MicroScan transducer consists of a 256-element array at frames up to 740 frames per second depending on the transducer type. Seven transducers are offered with frequencies ranging from 15 MHz to 50 MHz to serve multiple applications in imaging animal models ranging from zebrafish to rabbits. Vevo transducers are both hand held and mountable on an integrated Vevo imaging station. Each transducer can have up to three focus depths that can be adjusted to acquire the optimal image. All VisualSonics transducers can be used to acquire two modes to be viewed simultaneously. EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 2
3 o U.S. 7,230,368 Arrayed ultrasonic transducer o U.S. 6,984,284 Piezoelectric composites and methods for manufacturing same o U.S. 7,808,156 Ultrasonic matching layer and transducer o U.S. 7,750,536 High frequency ultrasonic transducer and matching layer comprising cyanoacrylate 3. IMAGING STATION 3-1 Integrated Vevo imaging station A heated handling table allows for secure positioning of the animal while maintaining physiological body temperature and overall physiological function. Two types of handling tables facilitate dedicated imaging for mice and another for rats. The transducer is mounted on the work station, and allows for hands-free scanning (image acquisition). In addition, physiological function can be observed and monitored from the animal platform (temperature, respiration, ECG and blood pressure). This information is displayed alongside the images and can be saved and exported for future reference. An integrated isoflurane-based anesthesia system accommodates dual connection set up to include oxygen or air. An injection mount allows for placement and positioning of syringes of different sizes o U.S. 7,133,713 Integrated multi-rail imaging system o U.S. 6,851,392 Small animal mount assembly 3-2 Image-guided injection using high-frequency ultrasound A component of the integrated Vevo imaging station Allows image-guided needle injections and extractions in real-time for targeted injection of cells, genetic material, drugs and retroviruses that can be visualized in small animal embryos through to adulthood. Improves injection target placement and reduces unnecessary costs of surgical procedures and animal recovery. 3-3 ECG and respiration gating ECG and respiration gating are used to suppress imaging artifacts due to respiration and cardiac movements. Both are important in cardiac and abdominal imaging for both 2D and 3D data sets. ECG gating is controlled, using the acquired ECG signal that is input to the system. The software allows for gating to be turned on or off. Respiration gating is controlled, using the respiration signal acquired also, by the system from the mouse/rat platform. The software allows for gating to be turned on or off. EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 3
4 o U.S. 7,133,713 o Integrated multi-rail imaging system U.S. 6,851,392; U.S. 7,426,904; U.S.7,434,542 Small animal mount assembly o U.S. 7,798,963 Method for Synchronization of Breathing Signal with Capture of Ultrasound Doppler Data 3-4 Integrated blood pressure capability The Vevo imaging system blood pressure input can be adjusted to accept a wide range of voltages from multiple types of blood pressure systems. The input gain of the blood pressure input can be adjusted within the software. Exact positioning of the catheter can also be visualized. Left ventricular pressure signals can be transferred into the Vevo imaging system simultaneously with left ventricle view to record real-time left ventricular inner diameter (LVID). Two-dimensional targeted M-Mode tracings can be recorded through the walls of the left ventricle Left ventricular pressure waveform input and pressure derivative (dp/dt) are superimposed on the electrocardiogram (ECG) trace, heart rate (HR), left ventricular systolic pressure (LVSP), body temperature and respiratory rate, all simultaneously monitored on the Vevo imaging system. Pressure/volume loops can be generated within the software. 4. Image analysis and software tools 4-1 Small animal-based measurements and annotations Over 200 small animal-based predetermined measurements and calculations embedded within the software. Facilitates an easier learning curve for new users in the animal laboratory which, in turn, improves efficiency and effectiveness. Measurements/calculations and annotations are customized to small animal anatomy and function (both units and terminology). Vevo imaging system image files can be opened and shared with multiple investigators (with permission) and re-measured and annotated for purposes of validation and verification. Multiple data sets can be aggregated to build larger study files. The researcher has complete control over how data is managed and reported. 4-2 Imaging data export and storage in multiple formats The Vevo imaging platforms allow for image capture, review and export as static images or as video files. Images can be copied as a group within a series/study, composite between series/studies or as individual images. The Vevo LAZR platform allows for image acquisition, review and export in multiple image formats (BMP, TIFF, GIFF) or cine loop files (AVI, GIFF, DICOM). Audio signal EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 4
5 from PW Doppler Mode files are also available for export as WAV audio files for flow analysis. Studies can easily be stored on the system, external device, disc or network. The flexibility offered with the Vevo LAZR platform data export enables researchers to compare animal to animal data sets with greater accuracy and integrity. VisualSonics remains at the leading edge of research by providing this facility. This is not currently available from any other ultrasound manufacturer. Hard drive capacity of 300 GB 4-3 Digital RF The Vevo 2100 imaging system allows for the export of IQ data (*.iq), envelope raw data (*.raw) or reconstructed RF data (*.rf). RF formats (Raw, IQ, RF) are available in all of the different software modes. The RF data can be reconstructed from IQ data by a process which includes interpolation of the I and Q signals and multiplication by a complex exponential e -jωt where ω=2πf; f= the quadrature sampling frequency and e -jωt = cos (2πf) + jsin (2πf). 4-4 Study management capabilities including user management mode and Time Logger Study based data management ability to add images/data to an existing study, this is ideal for long term studies Ability to perform multiple measurements/calculations on all images Ability to view images simultaneously in a side-by-side manner; aids in consistent imaging plane throughout the course of a study Ability to perform data analysis on an off-line computer; reserves time on the system for acquisition not analysis Analyze, label, annotate and archive images and studies through a flexible, openarchitecture system. Software supports industry standard Dicom 3.0, providing flexibility in the analysis and production of research data; the software also provides a wide variety of video, image, and data export formats compatible with PC based software. User magagement mode allows researchers to view their own data, Time logger records the amount of time a user account spends on the system, to be used for billing purposes in a core-lab environments with multiple users. 4-5 Vevo LAB workstation Workstation package includes all the post-processing software tools and features available on the Vevo imaging system. The software package allows for offline post-processing, detailed analyses and data management of previously acquired images. Installation in researchers offices accommodates access to the Vevo imaging system by other researchers for image acquisition. Compatible with Windows 7, XP and Vista EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 5
6 4-6 M-Mode M-Mode imaging produces quantifiable images to characterize moving anatomy, such as a cardiac wall motion, by selecting a line in the B-Mode image and observing it over time. Sample volume size down to 50 microns; adjustments can be made with sample sizes of 2 mm M-Mode cine loop has a maximum length of 30 seconds. 4-7Anatomical M-Mode A modification to standard M-Mode typically used in echocardiography. Allows the user to steer the sample volume to any angle they choose, rather than having the sample volume in a strict vertical position. 4-8 Pulse Wave (PW) Doppler Mode In PW Mode, the Vevo transducer emits a series of pulses to detect motion. The Doppler shift that is measured is processed and then shown on screen in a spectral display. Sampling rate for PW range from 1-2 khz to 125 khz; velocities that can be detected range from a few mm/s to approximately 6 m/s. Sweep speed parameter can be set in within a range from 0.25 seconds at 4000 Hz to 5.1 seconds at 200 Hz. 4-9 Power Doppler Mode Power Doppler assigns a color range to the energy generated by moving blood flow, according to intensity. Specifically designed for slow flow detection. Compatible with 3D Imaging 4-10 Color Doppler Mode Color Doppler uses PW Doppler Mode ultrasound to produce an image of directional flow in blood vessels. The system overlays colors on the image of the blood vessels to represent the speed and direction of blood flow through the vessels. Vascular flow moving toward the transducer is displayed in red hues. Vascular flow moving away from the transducer is displayed in blue hues. This mode allows quick detection of flow. o U.S. 7,674,228 System and method of ECG triggered receptive color flow imaging 4-11 Tissue Doppler Imaging Mode A software tool to assess tissue movement typically preformed on the myocardium. This tool is typically used to assess levels of diastolic function of the left ventricle by placing a sample volume at the mitral valve annulus, where changes in tissue motion are often detected prior to changes in blood flow spectrums through the same valve. Tissue Doppler Mode may also be used to assess regional myocardial strain, for example between the endocardium and epicardium in a model of myocardial infarction EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 6
7 4-12 3D Imaging 3D-Mode imaging provides tools to create and manipulate three-dimensional renderings and make volumetric measurements of objects viewed with highresolution ultrasound. Acquires a series of 2-dimensional slices (as small as 10 µm) and assembles them into a 3D data set that can then be visualized and manipulated. Targets (for example, tumor growth) can be segmented and volumetric measurements made. 3D imaging can be used in B-Mode, Power Doppler Mode or Contrast mode imaging procedures. 3D acquisition functionality allows for precise control of step size, range and slice thickness. This functionality can be integrated with ECG and respiration gating to suppress heart and respiratory artefacts. Range: min value = 0.5 mm; max value = 38 mm Step Size: min value = mm; max value = 0.5 mm; o U.S. 7,798,963 Method for synchronization of breathing signal with capture of ultrasound Doppler data D-Mode Thresholding A post-processing tool that optimizes and manages signal intensity for improved data analysis in nonlinear contrast mode 4-14 Contrast Imaging Software Linear and nonlinear contrast mode software tools are available Optimized to work with MicroMarker contrast agents Detection and quantification of soft and hard shell microbubbles Software optimized for molecular imaging experiments by allowing a destruction pulse to quantify microbubbles bound to their endothelial targets Patent o U.S. 8,275,449 Overlay Image Contrast Enhancement 4-15 Vevo CQ Vevo CQ software is state of the art post-processing software for quantification of capillary and microvascular hemodynamics and molecular expression. Perfusion parameters are derived from a curve fitting algorithm for both bolus kinetics and replenishment kinetics following destruction reperfusion Perfusion parameters include a series of calculations for amplitude, time and combination of amplitude and time Spatial rendering is available in the form of parametric maps Data can be exported in TIFF, BMP, video files and CSV formats 4-16 Vevo Color Highlight various anatomical targets in different colors for easy interpretation. Works in all software modes on the Vevo 2100 Imaging System. EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 7
8 4-17 VevoStrain TM Analysis Post-processing software based on a speckle tracking algorithm and provides information about the cardiac tissue at one point, at one segment or globally. Five analysis screens: The first four allow for analysis and vector displays, graph tracings, parametric displays for Velocity, Displacement, Strain and Strain Rate. The Secondary Analysis Screen displays overall cardiac tissue performance, segmental Time-to-Peak and segmental phase quantification EKV (ECG-Gated Kilohertz Visualization) A software tool for cardiovascular research to capture the high frame rates required for mouse and rat imaging (up to 650bpm) EKV offers the highest temporal resolution available in small animal imaging today, with EKV imaging and image reconstruction up to fps. With high temporal resolution, cardiac wall motions abnormalities can be assessed with exquisite image quality and resolution in diseased animal models. o U.S. 7,052,460 System for producing an ultrasound image line-based image reconstruction 4-19 ECG-Triggered - Respiration Gated Analysis 4-20 Vevo Vasc Supressess imaging artifacts due to respiration and cardiac movements Option for both 2D and 3D imaging Vascular software analysis package with automated vessel wall tracking for quantification of vascular strain, stiffness and thickness (including IMT measurements). Quantification of pulse propagation velocity is also available when used in combination with EKV software. Images can be exported in TIFF, AVI or CSVformats Vevo Vasc Ultra Combines Vevo Vasc and EKV software tools Allows quantification of pulse wave velocity EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 8
9 5. TRAINING VisualSonics is the only vendor to provide specialized applications/training support for high frequency ultrasound imaging of small animal models. Training is offered once the equipment is acquired, on-site, to provide customized training with researchers animal models. Workshops and specialized small animal imaging courses are also available in the North American and European headquarters. EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 9
10 FUJIFILM VisualSonics, Inc. INFORMATION NOTE: PRELIMINARY SPECIFICATION Information relating to this product and the application or design described herein is believed to be reliable, however such information is provided as a guide only and VisualSonics assumes no liability for any errors in this document, or for the application or design described herein. VisualSonics reserves the right to make changes to the product or this document at any time without notice. FUJIFILM VisualSonics, Inc. T Toll Free (North America) Toll Free (Europe) E. info@visualsonics.com VisualSonics, VisualSonics logo, VisualSonics dot design, Vevo, Vevo MicroMarker, VevoStrain, VevoCQ, SoniGene, RMV, EKV, MicroScan, LAZRTight, Insight through In Vivo Imaging, are registered trademarks (in some jurisdictions) or unregistered trademarks of VisualSonics Inc VisualSonics Inc. All rights reserved. EDU00508 Vevo 2100 Sole Source Specifications ver 3.4 Page 10
VEVO 1100 Sole Source Specifications
VEVO 1100 Sole Source Specifications Table of Contents 1.SYSTEM... 2 1-1 Licensing for the User... 2 1-2 Safety... 2 1-3 Portability... 2 2.TRANSDUCERS... 2 2-1 MicroScan transducers... 2 3. IMAGING STATION...
More informationHigh Resolution Multi-modal in vivo Imaging Platform
High Resolution Multi-modal in vivo Imaging Platform The world s only customizable imaging platform combining ultra high frequency ultrasound and photoacoustics Experience the next generation of in vivo
More informationBeginner s Guide to Vevo 2100
PN 12090 Beginner s Guide to Vevo 2100 December 2008 This Beginner s Guide to Vevo 2100 provides a quick overview of the Vevo 2100 imaging modes and provides key tips to allow users to start a study, acquire
More informationImaging Guide Pancreatic Imaging
Imaging Guide Guide to Small Animal Pancreatic Imaging using the Vevo 2100 Imaging System Ver 1.0 Guide to Small Animal Pancreatic Imaging using the Vevo 2100 Imaging System Course Objectives: This guide
More informationQuick Start Guide to the Vevo 770
Quick Start Guide to the Vevo 770 PN 11422 This Quick Start Guide provides a quick overview of the Vevo 770 and provides tips to allow users to start using the instrument and its various modes. A detailed
More informationVisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents
VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents 1 Objective Part Number: 11902 The objective of the 3D Tumor Imaging using the MicroMarker Non-Targeted
More informationGE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system
GE Healthcare Vivid 7 Dimension 08 Cardiovascular ultrasound system ltra Definition. Technology. Performance. Start with a system that s proven its worth in LV quantification and 4D imaging. Then add even
More informationQuick Start Guide to the Vevo 770
Quick Start Guide to the Vevo 770 PN 11422 This Quick Start Guide provides a quick overview of the Vevo 770 and provides tips to allow users to start using the instrument and its various modes. A detailed
More informationUltrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software
Ultrasound Q-Station software Streamlined workflow solutions Philips Q-Station ultrasound workspace software Managing your off-cart workf low Everyone is being asked to do more with fewer resources it
More informationLOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.
TM LOGIQ V2 Ultrasound Part of LOGIQ Vision Series Imagination at work The brilliance of color. The simplicity of GE. Now you can add the advanced capabilities of color Doppler to patient care with the
More informationVevo770 Ultrasound. Quick Operation Guide AIPT
Vevo770 Ultrasound Quick Operation Guide Vevo770 Probe head (707B/704) Preparation The acoustic membrane is very fragile and sensitive, it must be handled with care. The probe head should be filled with
More information3D Echocardiography Development Timeline
3D Acquisition Strategies and Display Lissa Sugeng, MD, MPH Associate Professor of Medicine Director of the Yale Echo Lab and Echo Core Lab (YCRG) And Peter Flueckiger, MD Advanced Imaging Cardiology Fellow
More informationBeyond Performance and Value
Putting the back in ultrasound Beyond Performance and Value Esaote s new ultra-performance MyLab 9 exp ultrasound system is designed to support a full range of shared service diagnostic imaging environments.
More informationRevolutionary. Heart Valve Durability Tester. VDT-3600i. Medical Device Testing & Equipment Simulation Platforms Silicone Vessels
Revolutionary Heart Valve Durability Tester VDT-3600i Medical Device Testing & Equipment Simulation Platforms Silicone Vessels The revolutionary heart valve durability tester from BDC Labs offers the most
More informationBeyond Performance and Value
Putting the back in ultrasound Beyond Performance and Value Esaote s new ultra-performance MyLab 9 exp ultrasound system is designed to support a full range of shared service diagnostic imaging environments.
More informationCertificate in Clinician Performed Ultrasound (CCPU)
Certificate in Clinician Performed Ultrasound (CCPU) Syllabus Physics Tutorial Physics Tutorial Purpose: Training: Assessments: This unit is designed to cover the theoretical and practical curriculum for
More informationVisualSonics Vevo 770 High-Resolution Imaging System. Operator Manual
VisualSonics Vevo 770 High-Resolution Imaging System Operator Manual VisualSonics Vevo 770 High-Resolution Imaging System Operator Manual January 2006 PN 11322 Revision 1.3 V1.3 VisualSonics Vevo 770
More informationMindray. Hand-carried Diagnostic Ultrasound System. Expanding the Envelope of Performance and Flexibility
M7 Mindray M7 Hand-carried Diagnostic Ultrasound System Expanding the Envelope of Performance and Flexibility M7 Diagnostic Ultrasound System Equipped for Quality Radiology Cardiology Outpatient Emergency
More informationAN ULTRA-SOUND AND DOPPLER MEDICAL IMAGE ANALYSIS FRAMEWORK
AN ULTRA-SOUND AND DOPPLER MEDICAL IMAGE ANALYSIS FRAMEWORK Ioan Stoian*, Ovidiu Dancea*, Mihaela Gordan**, Adina Stoian***, Gratian Botis**** * S.C. IPA S.A. Cluj-Napoca Subsidiary 109 Republicii Str.,400489
More informationEchoPAC Software Only v201
EchoPAC Software Only v201 Product Description The EchoPAC Application is a comprehensive clinical software package for viewing, analyzing, and reporting of multi-dimensional echo, vascular and abdominal
More informationQuick Guide. EPIQ 7 Ultrasound System. English
Quick Guide EPIQ 7 Ultrasound System English Contents For easy reference, each section is color-coded. The color of each section title correlates with the color band on each page in that section. Controls
More informationQuick reference guide. MyLab50
Quick reference guide MyLab50 Quick reference guide MyLab50 Introduction This Quick Guide describes only the basic operating procedures for the diagnostic ultrasound MyLab50 Family, named in the following
More informationClinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis
Clinical Importance Rapid cardiovascular flow quantitation using sliceselective Fourier velocity encoding with spiral readouts Valve disease affects 10% of patients with heart disease in the U.S. Most
More informationstep into the future Ultrasound Diagnostic Imaging System
step into the future Ultrasound Diagnostic Imaging System Moving into a new era for ultrasound diagnostics. With a proven track record in medical imaging, FUJIFILM has partnered with SonoSite, an innovator
More information4DM Packages. 4DM Packages & License Types. Information to help you order the appropriate licenses for your site.
4DM Packages 4DM Packages & License Types. Information to help you order the appropriate licenses for your site. Nuclear Cardiac Quantification, Review, and Reporting Select Your 4DM Package and corresponding
More informationM2M GEKKO. State-of-the-art phased-array flaw detector with TFM
M2M GEKKO State-of-the-art phased-array flaw detector with TFM USER FRIENDLY FLAW DETECTOR Gekko is the only compact phased-array ultrasound testing (PAUT) instrumentation offering intuitive PA features
More informationMedical Images Analysis and Processing
Medical Images Analysis and Processing - 25642 Emad Course Introduction Course Information: Type: Graduated Credits: 3 Prerequisites: Digital Image Processing Course Introduction Reference(s): Insight
More informationVolumetric Analysis of the Heart from Tagged-MRI. Introduction & Background
Volumetric Analysis of the Heart from Tagged-MRI Dimitris Metaxas Center for Computational Biomedicine, Imaging and Modeling (CBIM) Rutgers University, New Brunswick, NJ Collaboration with Dr. Leon Axel,
More informationSI8000 Cell Motion Imaging System
SI8000 Cell Motion Imaging System New Product Award Sony Biotechnology Inc. SI8000 Cell Motion Imaging System The Sony SI8000 Cell Motion System uses high speed video microscopy to detect and record cell
More informationTechnical Principles of Transthoracic Three-Dimensional Echocardiography
Technical Principles of Transthoracic Three-Dimensional Echocardiography 2 Stein Inge Rabben 2.1 Introduction The last years we have experienced a rapid development in three-dimensional echocardiography
More informationMR Advance Techniques. Vascular Imaging. Class III
MR Advance Techniques Vascular Imaging Class III 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology
More informationSONOS 7500/5500 Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision D.1
SONOS 7500/5500 Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision D.1 User s Guide Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision
More informationUS 1.
US 1 Sample image: Normal pancreas seen on sonogram. Looking up from abdomen toward the head of the patient. The liver is in front of the pancreas. A vein draining the spleen is behind the pancreas http://www.radiologyinfo.org/photocat/photos.cfm?image=abdo-us-pancr.jpg&&subcategory=abdomen&&stop=9
More informationThe Near Future in Cardiac CT Image Reconstruction
SCCT 2010 The Near Future in Cardiac CT Image Reconstruction Marc Kachelrieß Institute of Medical Physics (IMP) Friedrich-Alexander Alexander-University Erlangen-Nürnberg rnberg www.imp.uni-erlangen.de
More informationMagnetic Resonance Elastography (MRE) of Liver Disease
Magnetic Resonance Elastography (MRE) of Liver Disease Authored by: Jennifer Dolan Fox, PhD VirtualScopics Inc. jennifer_fox@virtualscopics.com 1-585-249-6231 1. Overview of MRE Imaging MRE is a magnetic
More informationGE Healthcare. Vivid E9 XDclear. with
GE Healthcare Vivid E9 XDclear with capabilities for every day Whether in TTE or TEE, capture the entire heart in a single beat. Image a valve, or the entire ventricle with excellent image quality. And
More informationUltrasound To Go. The MySono U5 -
Ultrasound To Go The MySono U5 - Ultrasound To Go With the introduction of the MySono U5, MEDISON brings you a fully featured ultrasound imaging system to go. Delivering exceptional image quality and featuring
More informationHatteras Instruments MC4000 Blood Pressure Analysis System Technical Synopsis
Model MC4000 Hatteras Instruments MC4000 Blood Pressure Analysis System Technical Synopsis Introduction The MC4000 Blood Pressure Analysis System combines the latest in blood pressure analysis technology
More informationLearning Anatomical Image Representations for Cardiac Imaging
Imperial College of Science, Technology and Medicine Department of Computing Learning Anatomical Image Representations for Cardiac Imaging Ozan Oktay A dissertation submitted in part fulfilment of the
More informationThe Supreme 3D/4D Ultrasound. The Supreme 3D/4D Ultrasound. CT-V20-ICM
The Supreme 3D/4D Ultrasound The Supreme 3D/4D Ultrasound www.medison.com info@medison.com CT-V20-ICM-06.20.2008 The Supreme 3D/4D Ultrasound Since launching the first commercially available 3D ultrasound
More informationImprove your image. ClearVue 550 ultrasound system. The print quality of this copy is not an accurate representation of the original.
Improve your image ClearVue 550 ultrasound system Not yet available in the U.S. Smart and intuitive One look at the Philips ClearVue 550 ultrasound system and you ll see the smooth, graceful lines and
More information7D Cardiac Flow MRI: Techniques & Automation of Reconstruction
Cleveland State University EngagedScholarship@CSU ETD Archive 2012 7D Cardiac Flow MRI: Techniques & Automation of Reconstruction Michael G. Ambrosia Cleveland State University Follow this and additional
More informationWhite Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space
White Pixel Artifact Caused by a noise spike during acquisition Spike in K-space sinusoid in image space Susceptibility Artifacts Off-resonance artifacts caused by adjacent regions with different
More informationSegment CT Instructions For Use - English
Segment CT Instructions For Use - English February 28, 2018 Software platform v2.2 R6239 MEDVISO AB http://www.medviso.com Griffelvägen 3 SE-224 67 Lund Sweden Tel: +46-76-183 6442 ii Contents 1 Terms
More informationModule 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.
MRES 7005 - Fast Imaging Techniques Module 5: Dynamic Imaging and Phase Sharing (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review Improving Temporal Resolution True-FISP (I) True-FISP (II) Keyhole
More informationA powerful, software-based beamformer image reconstruction platform
csound A powerful, software-based beamformer image reconstruction platform Figure 1: Vivid S70 and E90/95; first GE systems built upon the csound platform Background GE s cardiovascular ultrasound imaging
More informationFront-line research in Ultrasound CFU research Part 2: Fast Vector Flow Imaging, Pressure Gradients, Super Resolution and Portable Scanners
Front-line research in Ultrasound CFU research Part 2: Fast Vector Flow Imaging, Pressure Gradients, Super Resolution and Portable Scanners Can measure 3-D flow fast with only 124 transducer elements?
More informationThis is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up.
The Volume Strikes Back Press the (4D) button. This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up. In the Left GUI (Graphic User Interface), you
More informationAdvanced Dynamic Triaxial Testing System (DYNTTS)
Advanced Dynamic Triaxial Testing System (DYNTTS) Overview: The Advanced Dynamic Triaxial Testing System (DYNTTS) is a high-end testing apparatus combining a triaxial cell with a dynamic actuator capable
More informationn o r d i c B r a i n E x Tutorial DSC Module
m a k i n g f u n c t i o n a l M R I e a s y n o r d i c B r a i n E x Tutorial DSC Module Please note that this tutorial is for the latest released nordicbrainex. If you are using an older version please
More informationGE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.
GE Healthcare CLINICAL GALLERY Discovery * MR750w 3.0T This brochure is intended for European healthcare professionals. NEURO PROPELLER delivers high resolution, motion insensitive imaging in all planes.
More informationAnnexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER
Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER A) Scanner Design X-Ray generator and tube: 1. Scanner: Whole body spiral CT scanner (16 slices) of latest technology.
More informationUNIVERSITY OF SOUTHAMPTON
UNIVERSITY OF SOUTHAMPTON PHYS2007W1 SEMESTER 2 EXAMINATION 2014-2015 MEDICAL PHYSICS Duration: 120 MINS (2 hours) This paper contains 10 questions. Answer all questions in Section A and only two questions
More informationINDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY
INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY VERIFICATION AND ANALYSIS M. L. Hsiao and J. W. Eberhard CR&D General Electric Company Schenectady, NY 12301 J. B. Ross Aircraft Engine - QTC General
More informationThe University of Chicago. Center for EPR Imaging in Vivo Physiology. Image Registration. Boris Epel
The University of Chicago Center for EPR Imaging in Vivo Physiology Image Registration Boris Epel Imaging Methods are Complimentary CT MRI EPRI High resolution anatomic images Quantitative Poor soft tissue
More informationMyLab Alpha Quick Start
MyLab Alpha Quick Start Basic Setup The system has a 2.5 minute start time, but can be put in standby mode to allow for an 8 second boot time. From the patient data screen, click on the Menu button Then
More informationImage Acquisition Systems
Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS
More informationKNOBOLOGY. Jamie Ternes, RVT William Beaumont Hospital Royal Oak, Michigan. From the Beginning
KNOBOLOGY Jamie Ternes, RVT William Beaumont Hospital Royal Oak, Michigan From the Beginning Power On/Off Patient information Presets Probe selection Scan 1 Modalities /Gray scale/2d Pulse Wave Doppler
More informationPRODUCT SHEET. NON-INVASIVE SMALL ANIMAL TAIL BLOOD PRESSURE SYSTEMS NIBP250 Blood Pressure Amplifier NIBP200A Blood Pressure System
NON-INVASIVE SMALL ANIMAL TAIL BLOOD PRESSURE SYSTEMS NIBP250 Blood Pressure Amplifier NIBP200A Blood Pressure System NIBP Amplifiers with built-in pump automatically inflate the tail cuff to occlude the
More informationDeviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies
g Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies Presented by Adam Kesner, Ph.D., DABR Assistant Professor, Division of Radiological Sciences,
More informationFiche technique IndUScan V3
Produit IndUScan Dossier Date 28/08/15 Page 1 / 5 I / Presentation The IndUScan is an industrial system of ultrasonic control and acquisition. It combines ultrasonic, piloting, and interfacing electronics
More information4D Auto MVQ (Mitral Valve Quantification)
4D Auto MVQ (Mitral Valve Quantification) Federico Veronesi, Glenn Reidar Lie, Stein Inge Rabben GE Healthcare Introduction As the number of mitral valve repairs is on the rise, so is the need for mitral
More informationACUSON P300 Ultrasound System Control Panel Diagram
www.siemens.com ACUSON P300 Ultrasound System Control Panel Diagram 1 Power On / Off 1 2 TGC Controls 3 Left Mouse Click 4 Action 4 7 5 Right Mouse Click 6 Trackball 2 3 6 5 8 7 Pointer 8 Freeze 16 Color
More informationUltrafast Ultrasound Localization Microscopy. Olivier Couture Institut Langevin Wave Physics for Medicine Team. January 20 th 2017
Ultrafast Ultrasound Localization Microscopy Olivier Couture Institut Langevin Wave Physics for Medicine Team January 20 th 2017 The trade-off between resolution and penetration is often seen as incompressible
More informationGamepad Controls. Figure 1: A diagram of an Xbox controller. Figure 2: A screenshot of the BodyViz Controller Panel. BodyViz 3 User Manual 1
BodyViz User Manual Gamepad Controls The first step in becoming an expert BodyViz user is to get acquainted with the Xbox gamepad, also known as a controller, and the BodyViz Controller Panel. These can
More informationImprove your image. ClearVue 550 ultrasound system
Improve your image ClearVue 550 ultrasound system Smart and intuitive One look at the Philips ClearVue 550 ultrasound system and you ll see the smooth, graceful lines and elegant design that show this
More informationComputer-Aided Diagnosis in Abdominal and Cardiac Radiology Using Neural Networks
Computer-Aided Diagnosis in Abdominal and Cardiac Radiology Using Neural Networks Du-Yih Tsai, Masaru Sekiya and Yongbum Lee Department of Radiological Technology, School of Health Sciences, Faculty of
More informationSIVIC GUI Overview. SIVIC GUI Layout Overview
SIVIC GUI Overview SIVIC GUI Layout Overview At the top of the SIVIC GUI is a row of buttons called the Toolbar. It is a quick interface for loading datasets, controlling how the mouse manipulates the
More informationBrilliance CT Big Bore.
1 2 2 There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration.
More informationUltrasound To Go. MySono U5
Ultrasound To Go MySono U5 Ultrasound To Go With the introduction of the MySono U5, Samsung Medison brings you a fully featured ultrasound imaging system to go. Delivering exceptional image quality and
More informationComputed tomography - outline
Computed tomography - outline Computed Tomography Systems Jørgen Arendt Jensen and Mikael Jensen (DTU Nutech) October 6, 216 Center for Fast Ultrasound Imaging, Build 349 Department of Electrical Engineering
More informationChapter 9 Conclusions
Chapter 9 Conclusions This dissertation has described a new method for using local medial properties of shape to identify and measure anatomical structures. A bottom up approach based on image properties
More informationChapter 32 3-D and 4-D imaging in Obstetrics and Gynecology
Objectives Define common terms related to 3D/4D ultrasound Chapter 32 3-D and 4-D imaging in Obstetrics and Gynecology Bridgette Lunsford Describe how 3D and 4D imaging differs from 2D ultrasound Identify
More informationFOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION
Philips J. Res. 51 (1998) 197-201 FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION This special issue of Philips Journalof Research includes a number of papers presented at a Philips
More informationWhat you should know about the new release
T.A8.4401-01 TomTec-Arena 1.1 What you should know about the new release Congratulations to the purchase of your new TomTec Software TomTec-Arena and thank you for choosing TomTec Imaging Systems GmbH
More informationGE Healthcare. Agile Ultrasound. The Next Revolution in Ultrasound Imaging
Agile Ultrasound The Next Revolution in Ultrasound Imaging Abstract Diagnostic use of ultrasound has greatly expanded over the past couple of decades because it offers many advantages as an imaging modality.
More informationRat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy
Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy In this example you will load a dynamic MRS animal data set acquired on a GE 3T scanner. This data was acquired with an EPSI sequence
More informationLecture 6: Medical imaging and image-guided interventions
ME 328: Medical Robotics Winter 2019 Lecture 6: Medical imaging and image-guided interventions Allison Okamura Stanford University Updates Assignment 3 Due this Thursday, Jan. 31 Note that this assignment
More informationCorridor4DM Feature List
Software Services Features Corridor4DM Feature List 4DM v2013 FDG PET Standard Uptake Value (SUV) Calculation Auto-Selection of Report Template Motion Correction of SPECT datasets New Normals Databases
More informationSupplementary Figure 1
Supplementary Figure 1 BOLD and CBV functional maps showing EPI versus line-scanning FLASH fmri. A. Colored BOLD and CBV functional maps are shown in the highlighted window (green frame) of the raw EPI
More informationTechnical Specifications for High speed PIV and High speed PIV-PLIF system
Technical Specifications for High speed PIV and High speed PIV-PLIF system MODULE A. HIGH SPEED PIV (3-C) A1. Double Cavity High Speed Laser (up to 10 khz): The vendor should provide Dual Head (DH) laser
More informationYour versatile performer to depend on. Ultrasound. Philips ClearVue ultrasound family
Ultrasound ClearVue Your versatile performer to depend on Philips ClearVue ultrasound family Over 70 countries More than 5,000 systems Touching 25 million lives every year For one versatile family Dependability
More informationThe Latest Technology. Digi-Lite TM Key Features & Benefits
Digi-Lite TM The Latest Technology Digi-Lite TM is a Digital Transcranial Doppler (TCD) System with an advanced and proprietary M-Mode display. The product is based on the latest technology in digital
More informationGE Healthcare. Vivid E9 XDclear. with. healthymagination. GE imagination at work
GE Healthcare with Vivid E9 XDclear healthymagination GE imagination at work Extraordinary capabilities Whether in TTE or TEE, capture the entire heart in a single beat. Image a valve, or the entire ventricle
More information997-10, Daechi-dong, Gangnam-gu, Seoul, , Korea Tel: Fax:
997-10, Daechi-dong, Gangnam-gu, Seoul, 135-280, Korea Tel:080-337-2003 Fax: 02-2194-1209 * Indicates feature in development. Some equipment and software mentioned or shown in this brochure may be optional
More informationAdvanced Image Reconstruction Methods for Photoacoustic Tomography
Advanced Image Reconstruction Methods for Photoacoustic Tomography Mark A. Anastasio, Kun Wang, and Robert Schoonover Department of Biomedical Engineering Washington University in St. Louis 1 Outline Photoacoustic/thermoacoustic
More informationImprove your image. ClearVue 350 ultrasound system
Improve your image ClearVue 350 ultrasound system Smart and intuitive The system looks sleek from the outside, but it s what s on the inside that you ll value most. ClearVue 350 introduces Philips proprietary
More informationBy your side. Anytime. Anywhere.
By your side. Anytime. Anywhere. Portability without compromise If unrestricted access and diagnostic performance at the point of care are your priorities, Viamo c100 is your ideal solution. Viamo c100
More informationcsound 2.0 Vivid E95 gehealthcare.com Background
csound 2.0 Vivid E95 Background Through the Healthymagination initiative, GE Healthcare continuously invests in innovations that help lower the cost, increase access, and improve the quality of healthcare.
More informationImage Optimisation. -How to Get the Most out of your Echo Machine. Katarina Winkler, Biomedicinsk analytiker, Barnhjärtcentrum i Lund
Image Optimisation -How to Get the Most out of your Echo Machine analytiker, Barnhjärtcentrum i Lund Image Optimisation Helpful tips to improve the 2D-Image and Doppler registrations. Common adjustments
More informationSONOSITE X-PORTE TRANSDUCERS
SONOSITE X-PORTE TRANSDUCERS C11xp 8-5 MHz Curved Abdominal, Arterial, Neonatal, Nerve, Venous C35xp 8-3 MHz Curved Abdominal, MSK, Nerve C60xp 5-2 MHz Curved Abdominal, Gynecology, MSK, Nerve, Obstetrics
More informationLightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France
Lightsheet Z.1 Light Sheet Fluorescence Microscopy by Carl Zeiss Fabrice Schmitt, Sales Manager Carl ZEISS France 12.12.2012 Light Sheet Fluorescence Microscopy (LSFM) Principle The Principle of Light
More informationmicroct Systems for Life Science Innovation with Integrity High Resolution Microtomography for in vivo and ex vivo Applications Microtomography
microct Systems for Life Science High Resolution Microtomography for in vivo and ex vivo Applications Innovation with Integrity Microtomography SkyScan 1278 High Throughput Large Field of View in vivo
More informationRare Event Detection Algorithm. User s Guide
Rare Event Detection Algorithm User s Guide Copyright 2008 Aperio Technologies, Inc. Part Number/Revision: MAN 0123, Revision A Date: September 2, 2008 This document applies to software versions Release
More informationFluorescence Tomography Source Reconstruction and Analysis
TECHNICAL NOTE Pre-clinical in vivo imaging Fluorescence Tomography Source Reconstruction and Analysis Note: This Technical Note is part of a series for Fluorescence Imaging Tomography (FLIT). The user
More informationCP Generalize Concepts in Abstract Multi-dimensional Image Model Component Semantics. David Clunie.
CP-1390 - Generalize Concepts in Abstract Multi-dimensional Image Model Semantics Page 1 STATUS Date of Last Update Person Assigned Submitter Name Submission Date Assigned 2014/06/09 David Clunie mailto:dclunie@dclunie.com
More informationIMAGING SOFTWARE. Image-Pro Insight Image Analysis Made Easy. Capture, Process, Measure, and Share
IMAGING SOFTWARE Image-Pro Insight Image Analysis Made Easy Capture, Process, Measure, and Share Image-Pro Insight Image Analysis Made Easy Capture, Process, Measure, and Share Image-Pro Insight, the latest
More informationPhased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability
19 th World Conference on Non-Destructive Testing 2016 Phased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability Jason HABERMEHL 1, Nicolas BADEAU 1, Martin ST-LAURENT 1, Guy
More informationSection 9. Human Anatomy and Physiology
Section 9. Human Anatomy and Physiology 9.1 MR Neuroimaging 9.2 Electroencephalography Overview As stated throughout, electrophysiology is the key tool in current systems neuroscience. However, single-
More informationVelocity Measurement to Assess Nodularity in Ductile Iron Cast Automotive Components
Echomac VM Velocity Measurement to Assess Nodularity in Ductile Iron Cast Automotive Components As the use of nodular graphite iron material has expanded in recent years for automotive safety parts, ultrasonic
More information