Station 2. Inverter. PU connector (Note1)
|
|
- Dennis Carr
- 5 years ago
- Views:
Transcription
1 using the E500 series drives General This data sheet describes the correct techniques for using E500 series inverters on a standard RS485 serial comms link. Up to 32 inverters may be connected. Max comms speed is Baud. More information can be found in the E500 instruction manual The can be used for communication operation from a personal computer etc. When the is connected with a personal, FA or other computer by a communication cable, a user program allows the inverter to be run and monitored and the parameter values to be read and written. pin-outs Viewed from the inverter (receptacle side) front 8) to 1) 1) SG 2) P5S 3) RDA 4) SDB 5) SDA 6) RDB 7) SG 8) P5S Note: 1. Do not connect the to a computer's LAN board, FAX modem socket or telephone modular connector. Otherwise, the product may be damaged due to electrical specification differences. 2. Pins 2) and 8) (P5S) provide power to the control panel or parameter unit. Do not use these pins for communication. 1. with interface used with several inverters Station 2 Station n Interface / Distribution 10BASE-T cable Termination resistor Title: with E500 s Page 1 of 5
2 2. When a computer having a RS-232C interface is used with inverters RS-232C connector RS-232C cable Max. 15m Converter* Distribution 10BASE-T cable Termination resistor 3. Wiring of one computer and one inverter Side Terminals Signal name RDA RDB SDA SDB RSA RSB CSA CSB SG FG Description Receive data Receive data Send data Send data Request to send Request to send Clear to send Clear to send Signal ground Frame ground Cable connection and signal direction 10 BASE-T Cable (Note 2) 2 0.3mm or more SDA SDB RDA RDB SG 4. Wiring of one computer and "n" inverters (several inverters) Note: 1. There may be the influence of reflection depending on the transmission speed and/or transmission distance. If this reflection hinders communication, provide a termination resistor. If the is used to make a connection, use the distributor as a termination resistor cannot be fitted. Connect the termination resistor to only the inverter remotest from the computer. (Termination resistor: 100Ω) 2. Make connections in accordance with the instruction manual of the computer used. Fully check the numbers of the computer as they differ between models. Title: with E500 s Page 2 of 5
3 5. Preparation Connection cable... Connector: RJ45 connector Cable: Cable conforming to EIA568 (e.g. 10BASE-T cable) Personal computer, RS-232C converter... To be prepared when the communication port of the personal computer has RS-232C specifications. Parameters Related to serial communications Pr. 117 "station number" Pr. 118 "communication speed" Pr. 119 "stop bit length/data length" Pr. 120 "parity check presence/absence" Pr. 121 "number of communication retries" Pr. 122 "communication check time interval" Pr. 123 "waiting time setting" Pr. 124 "CR, LF presence/absence selection" Used to perform required settings for communication between the inverter and personal computer. Title: with E500 s Page 3 of 5
4 6. Communication specifications Conforming standard Number of inverters connected 1:N (maximum 32 inverters) Communication speed Selectable between 19200, 9600 and 4800bps Control protocol Asynchronous Communication method Half-duplex Communication Character system ASCII (7 bits/8 bits) selectable specifications Stop bit length Selectable between 1 bit and 2 bits. Terminator CR/LF (presence/absence selectable) Check system Parity check Selectable between presence (even/odd) and absence Sum check Present Waiting time setting Selectable between presence and absence Parameter Number Factory Setting Setting Range to , 96, Data length 8 0, 1 Data length 7 10, , 1, to 10, to s, to 150, , 1, 2 Title: with E500 s Page 4 of 5
5 7. Setting Parameter Number Name Setting Description 117 Station number 0 to 31 Station number specified for communication from the. Set the inverter station numbers when two or more inverters are connected to one personal computer. 118 Communication baud speed baud baud 119 Stop bit 8 data 0 Stop bit length 1 bit 1 Stop bit length 2 bits 7 bits 10 Stop bit length 1 bit 11 Stop bit length 2 bits 120 Parity check 0 Absent 1 Odd parity present 2 Even parity present 121 Number of communication retries 0 to 10 Set the permissible number of retries at occurrence of a data receive error. If the number of consecutive errors exceeds the permissible value, the inverter will come to an alarm stop (65535) If a communication error occurs, the inverter will not come to an alarm stop. At this time, the inverter can be coasted to a stop by MRS or RESET input. During an error, the light fault signal (LF) is given to the open collector output. Allocate the used with any of Pr. 190 to Pr. 192 (multifunction outputs). 122 Communication 0 No communication check time interval 0.1 to Set the communication check time [seconds] interval. If a no-communication state persists for longer than the permissible time, the inverter will come to an alarm stop Communication check suspension 123 Waiting time setting 0 to 150 Set the waiting time between data transmission to the inverter and response Set with communication data. 124 CR, LF 0 Without CR/LF instruction presence/ 1 With CR, without LF absence 2 With CR/LF Title: with E500 s Page 5 of 5
FR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION
MELSOFT FR Configurator SW3 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE FR-SW3-SETUP-WE -Windows (English) Version- OUTLINE WHEN USING FOR THE FIRST TIME SETTING WIZARD FUNCTION TROUBLE INDICATION INTRODUCTION
More informationFR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION
MELSOFT FR Configurator SW3 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE FR-SW3-SETUP-WE -Windows (English) Version- OUTLINE WHEN USING FOR THE FIRST TIME SETTING WIZARD FUNCTION TROUBLE INDICATION INTRODUCTION
More informationFR Configurator2 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE SW1DND-FRC2-E OUTLINE PROJECT CREATION FUNCTION TROUBLE INDICATION
FR Configurator2 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE SW1DND-FRC2-E OUTLINE 1 PROJECT CREATION 2 FUNCTION 3 TROUBLE INDICATION 4 INTRODUCTION Thank you for choosing this Mitsubishi Inverter Setup
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationFR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION
MELSOFT FR Configurator SW3 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE FR-SW3-SETUP-WE -Windows (English) Version- OUTLINE WHEN USING FOR THE FIRST TIME SETTING WIZARD FUNCTION TROUBLE INDICATION INTRODUCTION
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationGP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL. Keyence Corporation PLC
GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL Keyence Corporation PLC Reading the GP-PRO/PBIII Device/PLC Connection Manual This document is designed as an addition to the latest GP-PRO/PBIII for
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationFR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION
MELSOFT FR Configurator SW3 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE FR-SW3-SETUP-WE -Windows (English) Version- OUTLINE WHEN USING FOR THE FIRST TIME SETTING WIZARD FUNCTION TROUBLE INDICATION INTRODUCTION
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationAppendix 3 Using NS-AL002 Converters
Appendix 3 Using Converters The RS-232C/RS-422A Converter is connected directly to RS-232C port A or B of the, and converts RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix
More informationDevice/PLC Connection Manuals
Device/ Connection Manuals About the Device/ Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/ Connection manual"
More informationFR Configurator2 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE SW1DND-FRC2-E OUTLINE PROJECT CREATION FUNCTION TROUBLE INDICATION
FR Configurator2 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE SW1DND-FRC2-E OUTLINE 1 PROJECT CREATION 2 FUNCTION 3 TROUBLE INDICATION 4 INTRODUCTION Thank you for choosing this Mitsubishi Electric Inverter
More informationPower Mate Series Driver
FANUC LTD. Power Mate Series Driver 1 System Configuration... 3 2 Selection of External Device... 6 3 Example of Communication Setting... 7 4 Setup Items...10 5 Cable Diagram... 13 6 Supported Device...
More informationMelsec-Q Link(SIO) Driver
Mitsubishi Electric Melsec-Q Link(SIO) Driver 1 System Structure 2 Diagrams 3 Supported Device Addresses 4 Consecutive Device Addresses 5 Environment Setup 6 I/O Manager Configuration 7 Driver Configuration
More informationPC CONNECTION Programmable Terminal OPERATION MANUAL
Cat No. V042-E1-1 PC CNECTI Programmable Terminal OPERATI MANUAL PLC CNECTI Programmable Terminal Operation Manual Produced April 1997 iii OMR Product References All OMR products are capitalized in this
More informationPC CONNECTION Programmable Terminal Operation Manual
PC CONNECTION Programmable Terminal Operation Manual Produced March 1999 OMRON Product References All OMRON products are capitalized in this manual. The word Unit is also capitalized when it refers to
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationSIMATIC S5 CPU Direct Driver
Siemens AG SIMATIC S5 CPU Direct Driver 1 System Configuration... 3 2 Selection of External Device... 7 3 Example of Communication Setting... 8 4 Setup Items... 9 5 Cable Diagram... 14 6 Supported Device...
More informationOMRON Corporation PLC SYSMAC C Series Connection
OMRON Corporation PLC SYSMAC C Series Connection System Structure GP Machine Model Remark GP GLC GP70 Series GP77/77R Series GP2000 Series GLC2000 Series Excepting for handy types. OMRON SYSMAC-C Series
More informationFR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION
MELSOFT FR Configurator SW3 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE FR-SW3-SETUP-WE -Windows (English) Version- OUTLINE WHEN USING FOR THE FIRST TIME SETTING WIZARD FUNCTION TROUBLE INDICATION INTRODUCTION
More informationOMRON Corporation PLC SYSMAC CJ1M Series Connection
OMRON Corporation PLC SYSMAC CJ1M Series Connection Let s Connect to PLC! System Structure GP Product Model Remark GP GLC GP70 Series GP77/77R Series GP2000 Series GLC2000 Series Excepting for handy types.
More informationOMRON Corporation PLC SYSMAC C Series Connection
OMRON Corporation PLC SYSMAC C Series Connection System Structure GP Machine Model Remark GP GLC GP70 Series GP77/77R Series GP2000 Series GLC2000 Series Excepting for handy types. OMRON SYSMAC-C Series
More informationTHERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.
HEC-OM-S008 Aug.2014 Communication Manual THERMO-CON Model No. HECR002-A5 Keep available whenever necessary. This manual is copyrighted and all rights are reserved by SMC Corporation, and may not, in whole
More informationDevice/PLC Connection Manuals
Device/ Connection Manuals About the Device/ Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/ Connection manual"
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More informationDF1 Driver. Rockwell Automation, Inc.
Rockwell Automation, Inc. DF1 Driver 1 System Configuration... 3 2 Selection of External Device... 6 3 Example of Communication Setting... 7 4 Setup Items...23 5 Cable Diagram... 29 6 Supported Device...
More informationSchneider Electric TSX07/37/57 Series Unitelway Driver
Schneider Electric Schneider Electric TSX07/37/57 Series Unitelway Driver 1 System Structure 2 Diagrams 3 Supported Device Addresses 4 Consecutive Device Addresses 5 Environment Setup 6 I/O Manager Configuration
More information1.1 Siemens S5/S7 Series
1.1 Siemens S5/S7 Series 1.1.1 S5/ S7 Serial Interface The following section describes the system configuration and interface between Siemens S5/S7 series PLC and TOP using serial communication through
More informationSelect a Data Communication Interface
Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationMotors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual
Motors I Automation I Energy I Transmission & Distribution I Coatings SymbiNet CFW-11 User s Manual SymbiNet User s Manual Series: CFW-11 Language: English Document Number: 10002033446 / 00 Publication
More informationTHT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE
COMMUNICATION INSTRUCTION MANUAL THT-500-A/R (C5) No. THT5CE2 2018.04 This manual contains instructions for communication functions of the THT-500-A/R. 1. System Configuration 1.1 When Using USB Communication
More informationMitsubishi QSeries QnA Serial Communication
Mitsubishi QSeries QnA Serial Communication 2 Mitsubishi Q Series QnA Serial Communication MITSUBISHI QSERIES QNA SERIAL COMMUNICATION... 1 1. SYSTEM CONFIGURATION... 3 2. SYSTEM SETTINGS... 4 3. EXAMPLE...
More informationMCF. User's Manual. Air Flowmeter NPT Model. for Communication Functions. No. CP-SP-1301E
No. CP-SP-1301E TM MCF Air Flowmeter NPT Model User's Manual for Communication Functions Thank you for purchasing the MCF Air Flowmeter. This manual contains information for ensuring the correct use of
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationCitect for Windows Driver Specification Extract Hitachi Driver
Citect for Windows Driver Specification Extract Hitachi Driver Author: Date Action Rupert Reeve 13/11/95 Wrote it Bill Rayer 13/12/95 Modifications Masoud Varjavandi 16/1/96 Modified Huang Weiguang 15/12/2000
More informationSIMATIC S5 CPU Direct Driver
Siemens AG SIMATIC S5 CPU Direct Driver 1 System Configuration... 3 2 Selection of External Device... 6 3 Example of Communication Setting... 7 4 Setup Items... 8 5 Cable Diagram... 13 6 Supported Device...
More informationAD Leak Tester INSTRUCTION MANUAL 1WMPD
AD-1690 Leak Tester INSTRUCTION MANUAL 1WMPD4002043 2009 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language in
More informationINSTRUCTION MANUAL FOR JU THYRISTOR REGULATOR COMMUNICATIONS INTERFACE
INST. INE-325A INSTRUCTION MANUAL FOR JU THYRISTOR REGULATOR COMMUNICATIONS INTERFACE Always keep this manual with the unit and in an easily accessible place. Please make sure that this manual is delivered
More informationMDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24
MDNET-5W Wi-Fi/Ethernet/RS485 Converter Operation Manual Version 01.00 2016/03/24 I. Features & Specification Features: Connect RS485 devices to Ethernet or Wi-Fi network Connect Ethernet device to Wi-Fi
More informationFlexi Soft Driver SICK AG
SICK AG Flexi Soft Driver 1 System Configuration... 3 2 External Device Selection... 6 3 Communication Settings... 7 4 Setup Items... 9 5 Cable Diagrams... 15 6 Supported Device... 17 7 Device Code and
More informationAD Remote Controller INSTRUCTION MANUAL WM+PD A
AD-8922 Remote Controller INSTRUCTION MANUAL WM+PD4000929A 2005 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language
More informationSender Receiver Sender
EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other
More informationThis document hosted by: 10. OPTIONS
This document hosted by: www.oldwillknottscales.com 10. OPTIONS The following options are available for the FG series: OP-23 (FG-23) RS-232C serial interface OP-24 (FG-24) RS-232C serial interface and
More informationMounting the Model 2601
Control Technology Corporation Model 2601 Automation Controller Installation Guide Model 2601 Automation Controller This document is current as of the following revision levels: Controller Firmware 2.24
More informationModule Type Controller SRV. PLC/Host Communication Instruction Manual IMS01P05-E5 RKC INSTRUMENT INC.
Module Type Controller SRV PLC/Host Communication Instruction Manual RKC INSTRUMENT INC. IMS01P05-E5 Modbus is a registered trademark of Schneider Electric. The name of each programmable controller (PLC)
More informationXGK Series CPU Direct Driver
LS Industrial Systems Co., Ltd. XGK Series CPU Direct Driver 1 System Configuration... 3 2 Selection of External Device... 6 3 Example of Communication Setting... 7 4 Setup Items... 9 5 Cable Diagram...
More informationUSER S MANUAL Enhanced Communication Function
UM-TS02E -E003 PROGRAMMABLE CONTROLLER PROSEC T2E/T2N USER S MANUAL Enhanced Communication Function Main Menu Contents TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property
More informationSAPHIR SIO Driver. Siemens Building Technologies
Siemens Building Technologies SAPHIR SIO Driver 1 System Configuration... 3 2 External Device Selection... 6 3 Communication Settings... 7 4 Setup Items... 9 5 Cable Diagrams... 14 6 Supported Devices...
More informationModbus TCP Client Ethernet Modbus TCP Client Modbus TCP Server Ethernet Modbus TCP Server 5
Chapter 1 Connection Table Selecting RTU Master or TCP Client for the Communication Driver allows the user to use the 1:N Communication function ( Chapter 6 Communication with Multiple External Devices
More informationCML/CMF050 Series. User's Manual
No. CP-SP-1160E CML/CMF050 Series High-Flow Mass Flow Meter User's Manual Communications Thank you for purchasing the CML/ CMF050 Series High-Flow Mass Flow meter. This manual contains information for
More informationCopyright: December 2017 Nidec Issue: E
General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment
More informationPro-face Memory Link(SIO) Driver
Pro-face Pro-face Memory Link(SIO) Driver 1 About Memory Link 2 Memory Link Commands 3 System Structure 4 Cable Diagrams 5 Supported Device Addresses 6 Environment Setup 7 I/O Manager Configuration 8 Driver
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationHi5 Robot Driver. Hyundai Heavy Industries
Hyundai Heavy Industries Hi Robot Driver System Configuration... 3 2 Selection of... 7 3 Example of Communication Setting... 8 Setup Items... Cable Diagram... 2 Supported Device... 32 7 Device Code and
More informationINSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL Table of Contents Overview and Features.. 1 Specifications 2 Functional Block Diagram 3 Unit Detail. 4 DIP Switch Setting Tables 7 RS-232 I/F Pin Assignment.. 10 V.35
More informationLadder Communication Modules
Instruction Manual Ladder Communication Modules Yokogawa Electric Corporation 1st Edition i Preface Applicable Products FA-M3 Range-free Multi-controller Models and Their
More informationMaximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual
Maximum Value for OEMs SM NX7 Serial Communications Unit (SCU) User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.
More informationMODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE
INSTRUCTIONS MODBUS RTU MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-8-88-2131 Fax: 1-8-711-1616 www.worldwideelectric.net Product Compatibility This communications module is suitable
More informationUSER'S MANUAL - MODBUS Serial Communication Edition FX3U SERIES PROGRAMMABLE CONTROLLERS
USER'S MANUAL - MODBUS Serial Edition FX3U SERIES PROGRAMMABLE CONTROLLERS Safety Precautions (Read these precautions before use.) Before installing, operating, maintenance or inspecting this product,
More informationOperating Instructions. Sartorius. Description of the Interface for EA, EB, GD, GE and TE Balances/Scales
Operating Instructions Sartorius Description of the Interface for EA, EB, GD, GE and TE Balances/Scales Contents Intended Use 2 Contents 2 Intended Use 2 Configuring the Interface Parameter Settings (Menu)
More informationPlease read here first
) / - 6 1+ 6 4, 4 1 8-7 1 6 5-4 1-5 1 5 6 4 7 + 6 1 ) 7 ) 0 EC D 2 A H B H =? A 0 EC D. K? J E, + : # " J! % 2 4-2 - 4 ) 6 1 1. 4 ) 6 1 + D=FJAH 1 5 6 ) ) 6 + 1 D = F JA HH 9 1 4 1 / + D = F JA H! 0 9
More informationVoltage regulator TAPCON 240
Voltage regulator TAPCON 240 Supplement 2398420/00 Protocol description SPA-Bus All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and communication
More informationSeries 370 Stabil-Ion Gauge Controller with RS-485 Interface Option
Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option Introduction The RS-485 communications option (See Figure 1) for the Series 370 Stabil-Ion Gauge Controller permits data output to, and
More informationYaskawa Electric MP900 Series Driver
Yaskawa Electric Yaskawa Electric MP900 Series Driver 1 System Structure 2 Cable Diagrams 3 Supported Device Addresses 4 Consecutive Device Addresses 5 Environment Setup 6 Sample Ladder Program 7 I/O Manager
More informationA GUIDE TO RS-232 COMMUNICATION WITH FX PLCS
A GUIDE TO RS-232 COMMUNICATION WITH FX PLCS Page 1 of 35 A GUIDE TO RS-232 COMMUNICATION WITH FX PLCS This document has been written specifically for FX and FX0N users that are unfamiliar with RS-232
More informationAD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B
AD-8923-CC Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD4002124B 2013 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationRGAM Communication protocol description I 94 GB Date: March 10, 1999
RGAM Communication protocol description I 94 GB 03 99 Date: March 10, 1999 General features: Master-slave protocol, where usually the master is a Personal Computer or a device capable of communication
More informationOperating Instructions Sartorius
Operating Instructions Sartorius Description of the Interface for GD, GE and TE Balances/Scales Contents Intended Use 2 Contents 2 Intended Use 2 Configuring the Interface Parameter Settings (Menu) 3 Data
More informationSIMATIC S5 3964(R) Driver
Siemens AG SIMATIC S5 3964(R) Driver 1 System Configuration... 3 2 External Device Selection... 6 3 Communication Settings... 7 4 Setup Items...10 5 Cable Diagram... 14 6 Supported Device Addresses...
More informationVersaMax* Serial Communications Module
Product The VersaMax Serial Communications Module, IC200CMM020, operates as a Modbus RTU Master in a VersaMax I/O Station controlled by a Genius Network Interface Unit or a PROFINET Scanner. Revision Firmware
More informationGE Fanuc IC695CMM004. Rx3i PacSystem
GE Fanuc IC695CMM004 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695cmm004 Rx3i PacSystem RX3i serial communications module. Four isolated RS-232/485 port. IC695C IC695CM IC695CMM 919-535-3180
More informationEXCELL PRECISION CO., LTD.
Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part
More informationSetting the DCM Switches
20 The device(s) connected to the DCM will help you determine the appropriate switch settings. Host Computer or Operator Interface Connection If you re using a host computer or operator interface as the
More informationThe modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface
DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,
More informationConnecting to the Handy Type GP
Connecting to the Handy Type GP 1 System Structure 2 Optional Items 3 Preparing RS-232C/RS-422 Cables for the Series unit 4 Cable Diagrams This manual explains how to connect the target machine with devices
More informationThis document hosted by: Extension Load Cell Cable (OP-02)
This document hosted by: www.oldwillknottscales.com 17.1. Extension Load Cell Cable (OP-02) This cable is used for installing the indicator away from the base unit. This extension load cell cable is 5
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationKTA-250 Anemometer Alarm Card
Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments
More informationSerial Communication Prof. James L. Frankel Harvard University. Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved.
Serial Communication Prof. James L. Frankel Harvard University Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved. Overview of the Serial Protocol Simple protocol for communicating
More informationENMAT Premium Data Logger User Manual
Page 1 Information in this document is subject to change without notice. Copyright 2013 Envantage Ltd. All rights reserved. ENMAT is a trading name of Envantage Ltd. While the information contained in
More informationUser Manual Connection to Mitsubishi MelsecA
User Manual Connection to Mitsubishi MelsecA Part Number: 80 860.676 Version: 1 Date: 17.11.2005 Valid for: TSwin.net 4.1x Version Date Modifications 1 17.11.2005 First edition This manual, including all
More informationA Series CPU Direct Driver
Mitsubishi Electric Corporation A Series CPU Direct Driver 1 System Configuration... 3 2 Selection of External Device... 8 3 Example of Communication Setting... 9 4 Setup Items...12 5 Cable Diagram...
More informationNCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationModular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:
FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX
More informationLecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all
Lecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all bits of a data word are transformed simultaneously. This
More informationi-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products
i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual (Version 1.01) PAGE:1
More informationMODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
MODBUS-IN User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 12/17/14) Thank you for purchasing. This manual contains instructions and warnings that should be followed during the installation,
More informationDrawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.
Drawings SD PD-EN Model A Digital Indicating Controller (A-NNN-xx-xx/x) [Style: S] External Dimensions Unit: mm (approx. inch) 96 (.78) (.) 6 (.6) Bracket Terminal cover (.79) 96 (.78) 9.6 (.6) 9.6 (.7).
More informationTransmission/ reception tables
Transmission/ reception tables Message Exchange When in Transmit Only mode, the Control and Transmission tables are filled in prior to executing the EXCHx instruction, and can be of type %KW or %MW. No
More informationAD Leak Tester INSTRUCTION MANUAL 1WMPD B
AD-1690 Leak Tester INSTRUCTION MANUAL 1WMPD4002043B 2009 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language
More informationUL/c-UL(CSA) Approval
GP2000H Series RS-422 Conversion Adapter (GP2000H-AP422) Installation Guide Thank you for purchasing Pro-face's GP2000H Series RS-422 type Conversion Adapter, hereafter referred to as the "Adapter" Using
More informationUSER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH485Ex1 Doc No: PH485Ex1-UM-001 #1 RS-485 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationUser s Manual. LG Programmable Logic Controller. Computer Link Module K7F-CUEA MASTER-K K4F-CUEA K3F-CU2A K3F-CU4A. LG Industrial Systems
User s Manual LG Programmable Logic ontroller omputer Link Module K7F-UEA K4F-UEA K3F-U2A K3F-U4A LG Industrial Systems hapter 1 Introduction 1 Introduction... 1-1 hapter 1 Introduction 1 Introduction
More informationDN-01 Instruction Manual
DN-01 Instruction Manual DeviceNet communication expansion board V 1.00 This instruction manual is only for the Shihlin communication expansion board DN-01. Please refer to ODVA DeviceNet specification
More informationTOSVERT VF-S9 Communications Function Instruction Manual
TOSVERT VF-S9 Communications Function Instruction Manual Notice 1. Make sure that this instruction manual is delivered to the end user of the inverter. 2. Read this manual before first using the communications
More informationVorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual
Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric
More information