ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0
|
|
- Alan Dixon
- 6 years ago
- Views:
Transcription
1 ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0
2 Exam A QUESTION 1 An IPspace is associated with exactly one? A. broadcast domain B. SVM C. port D. root volume Correct Answer: A QUESTION 2 Which statement about LIFs is true? A. There is one cluster management LIF per node B. One port can host multiple data LIFs C. Cluster LIFs and data LIFs can share a port D. A data LIF can be associated with multiple SVMs Correct Answer: B QUESTION 3 A volume that is called "vs1_vol2" is created on aggregate aggr2. It is mounted in the namespace at /vs1/vol2. An administrator moves this volume to the aggr1 aggregate. What is the path to this volume after the move? A. /aggr1/vs1/vs1_vol2 B. /vs1/vol2 C. /vol/vs1_vol1
3 D. /aggr1/vs1_vol2 Correct Answer: B QUESTION 4 In clustered Data ONTAP 8.2 and later, what is the maximum number of nodes that can support a SAN protocol? A. 4 B. 8 C. 16 D. 24 Correct Answer: B QUESTION 5 Clustered Data ONTAP supports ALUA with which protocols? A. FC only B. FC and FCoE only C. FC, FCoE and iscsi only D. FC, FCoE, iscsi and NFS only
4 Correct Answer: C QUESTION 6 What is required for a LUN to serve data in a clustered Data ONTAP environment? A. A LUN requires a junction path to the global namespace B. A LUN requires igroup-to-lun mapping C. A LUN requires a mount point in the volume D. A LUN requires LUN reservation to be enabled E. All of the above Correct Answer: B QUESTION 7 When does a snapshot copy start taking up space? A. When a Snapshot copy is first created B. When a SnapRestore technology is first initiated C. When the Snapshot copy is reverted D. Only when the file system data changes after the Snapshot copy is created Correct Answer: D QUESTION 8
5 Snapshot technology is foundational for which of these NetApp products? A. SnapRestore B. SnapDrive C. Flexclone D. All of the above Correct Answer: D QUESTION 9 Which hidden directory contains Snapshot copies when viewed from a CIFS client? A..snapshot B. ~snapshot C. %snapshot D. ~backup Correct Answer: B QUESTION 10 When is the active file system used to store Snapshot copies? A. When the Snapshot reserve is completely full B. When the Snapshot reserve is set to 20% C. The active file system is always used for Snapshot copies D. After turning on fractional reserve Correct Answer: A
6 QUESTION 11 Which types of data compression are available in Data ONTAP? A. Inline and external B. Inline and preprocess C. Inline and postprocess D. Inline and reclaimable Correct Answer: C QUESTION 12 A FlexClone volume, by definition, shares no data blocks with its parent volume. A. True B. False Correct Answer: B QUESTION 13 Select the statement that is true about giveback with storage failover in clustered Data ONTAP. A. The surviving partner simultaneously returns ownership of all the aggregates to its partner node B. The surviving partner returns ownership of all the aggregates and the data LIFs to its partner
7 C. The surviving partner returns ownership of the root aggregate to its partner first, and then returns the other aggregates D. I/O resumes only when all aggregates are returned to the partner node Correct Answer: C QUESTION 14 Which MetroCluster configuration does Data ONTAP 8.3 support? A. Stretch B. Fabric C. Hybrid D. Cloud Correct Answer: B QUESTION 15 In a Data ONTAP 8.3 MetroCluster configuration, both two-node clusters can function as A. Independent clusters, each supporting its own workload B. Either an active cluster or a failover target, but not both simultaneously C. The failover cluster for a tertiary MetroCluster failover configuration D. A failover target for a 7-mode storage system Correct Answer: A
8 QUESTION 16 Which two NetApp data protection products create application-consistent backups? (Choose two) A. SnapDrive B. SnapManager C. SnapMirror D. SnapProtect E. SnapVault Correct Answer: BD QUESTION 17 From the output of the command "network interface show" the LIF that has a value of "false" under the "Is Home" column signifies that it. (Choose all that apply) A. Is disconnected B. Has failed over C. Is administratively disabled D. Has been migrated E. Is unhappy Correct Answer: BD QUESTION 18 Which two default SVM roles are available when an SVM is created? (Choose two) A. vsadmin-readonly B. root
9 C. vsadmin D. admin Correct Answer: AC QUESTION 19 A customer wants a different performance characteristics for applications that are using LUNs. They want to control the performance for FCP LUNs. Which two clustered ONTAP features QoS would you use to accomplish this task? (Choose two) A. setting the policy group for the SVM that is hosting the LUNs for the customer's application B. setting the policy group for the volumes that are hosting the LUNs for the customer's application C. setting the policy group for the FCP target ports that are being used for the LUNs D. setting the policy group for the igroups mapped to the LUNs that are hosting the customer's application Correct Answer: AD QUESTION 20 Which two backup engines are supported within clustered Data ONTAP (Choose two) A. SMtape B. dump C. tape D. xcopy Correct Answer: BC
10 QUESTION 21 Why would you use NetApp Snapshots? A. for data protection B. to increase performance C. for network resiliency D. for storage failover Correct Answer: A QUESTION 22 In the storage failover command, what does the bypass-optimization option do? A. It takesover the partner node without performing aggregate relocation B. It migrates all logical interfaces during takeover C. It takes over without migrating all logical interfaces D. It takes over the partner node performing aggregate relocation Correct Answer: A QUESTION 23 An administrator creates an account for a new user, and wants this user to have limited capabilities accessing SSH. The administrator defined the account, but the user still has full control. Which two settings would the administrator use to correct this problem? (Choose two) A. the user account settings in OnCommand system Manager B. the user account settings of the admin account C. the user account settings in Windows Active Directory Users and Computers
11 D. the user account settings in the clustershell Correct Answer: CD QUESTION 24 You change the volume junction-path of vol1 from /vol/vol1 to /vol1. NFS clients are unable to connect to the new path /vol1. Which mirrors need to be updated to solve this problem? A. TDP mirrors of the SVM root volume B. XDP mirrors of the SVM root volume C. DP mirrors of the SVM root volume D. LS mirrors of the SVM root volume Correct Answer: A QUESTION 25 When creating a data aggregate, what is the default minimum number of disks for RAID4 and RAID-DP? A. 5 for RAID4 and 9 for RAID-DP B. 4 for RAID4 and 7 for RAID-DP C. 3 for RAID4 and 5 for RAID-DP D. 2 for RAID4 and 3 for RAID-DP Correct Answer: C
12 QUESTION 26 What are the two valid settings for fractional reserve? (Choose two) A. 100% B. 20% C. 0% D. 50% Correct Answer: AC QUESTION 27 How many disks reside in a DS4246 shelf? A. 46 B. 42 C. 14 D. 24 Correct Answer: D QUESTION 28 Which two NFS versions are supported on clustered Data ONTAP 8.3? (Choose two) A. NFSv1 B. NFSv2 C. NFSv3 D. NFSv4
13 Correct Answer: CD QUESTION 29 A customer wants to use a UTA2 PCIe card in a new FAS8000 system. Which three steps must be completed before the customer is able to use the ports for FC access to an FCP switch? (Choose three) A. Use the system hardware unified-connect modify command to change the personality from initiator to target. B. Verify the WWPN of the UTA2 so that these can be used in the igroup to map the LUNs for host access. C. Verify that the correct SFP+ is installed for FC D. Verify the card's hardware configuration by running the system hardware unified-connect show command E. Verify that Data ONTAP iscsi, CIFS and NFS are licensed on the system Correct Answer: ACD QUESTION 30 Which two default SVM roles are available when an SVM is created? (Choose two) A. vsadmin-readonly B. root C. vsadmin D. admin
14 Correct Answer: AC QUESTION 31 In the storage failover command, what does the bypass-optimization option do? A. It takes over the partner node without performing aggregate relocation B. It migrates all logical interfaces during takeover C. I takes over without migrating all logical interfaces D. It takes over the partner node performing aggregate relocation. Correct Answer: A QUESTION 32 Which type of upgrade is supported from a single-node FAS2552 to a dual-node cluster with clustered Data ONTAP 8.3 when all 10 Gb ports are used for host access? A. a disruptive upgrade from a single-node cluster to a dual-node HA cluster B. a non-disruptive upgrade of a single-node cluster into a dual-node HA cluster C. a single-node cluster upgraded by migration of data to another single-node cluster D. a disruptive single-node cluster upgraded to a dual-node HA cluster by adding 10 Gb Ethernet cards Correct Answer: D QUESTION 33
15 Which two solutions are valid for clustered Data ONTAP MetroCluster? (Choose two) A. FAS3200 series controllers B. FAS2500 series controller C. four nodes at each site D. two nodes at each site Correct Answer: BD QUESTION 34 Which type of connectivity is supported when connecting third-party arrays through FlexArray Virtualization for back-end storage to a NetApp cluster? A. iscsi B. SAS C. FC D. Infiniband Correct Answer: C QUESTION 35 You have multiple volumes that are exported to a group of hosts within your environment. A new hosts needs access to the volumes. Which two actions accomplish this task? (Choose two) A. Mount the new exports from the host B. Create a new SVM C. Create a rule in the export policy on the SVM D. Create a new data LIF on the SVM Correct Answer: AC
16 QUESTION 36 You just added a vsphere host to your environment that needs access to the existing NFS datastore. The application export policy is named VMW, and each host's IP address has been given access. What should you do to grant the new host access to the NFS datastore A. Create a new volume B. Create a new rule under the VMW export policy C. Create a new SVM D. Create a new export policy for the new host Correct Answer: B QUESTION 37 A NetApp cluster is connected to two network switches for resiliency. One of the network switches loses power. Most LIFs on the cluster automatically recover from the switch failure to and are reachable through the network. One LIF used for CIFS access is not reachable through the network until power is restored to the failed switch. Which two area should be investigated to determine the problem? (Choose two) A. The protocols allowed on the LIFs B. The LIFs failover-group configuration C. The LIFs home port D. The broadcast domain's member ports Correct Answer: BC
17 QUESTION 38 An administrator is attempting to add two FAS8020 nodes to an existing cluster of eight FAS2552 nodes. They are receiving an error when attempting to join the new nodes. What is causing this error? A. The cluster switch connections have been cabled incorrectly B. The disk shelves on one of the new nodes are displaying an error C. The maximum number of nodes is already in the cluster D. The new nodes are running a newer version of clustered Data ONTAP Correct Answer: C QUESTION 39 Which clustershell prompt indicates that the administrative privilege is set? A. cs2552::*> B. cs > C. cs % D. cs2552::> Correct Answer: D QUESTION 40 NetApp Cloud ONTAP supports which cloud provider? A. Singlehop B. Amazon (AWS) C. Skytap D. Rackspace
18 Correct Answer: B QUESTION 41 Which NetApp tool will identify the number of onboard UTA2 ports on a FAS8060? A. Interoperability Matrix Tool B. Hardware Universe C. OnCommand Performance Manager D. OnCommand Unified Manager Correct Answer: B QUESTION 42 Clustered Data ONTAP supports which three types of SVMs? (Choose three) A. inter-cluster B. vfiler C. data D. node E. admin Correct Answer: CDE QUESTION 43
19 Which NetApp management product is used to enable the iscsi protocol? A. OnCommand System Manager B. OnCommand Insight C. Virtual Storage Console D. My Autosupport Correct Answer: A QUESTION 44 Your customer plans to upgrade an application that will now require block-based LUNs. The previous version of the application used SMB shares. The customer has a 2-node FAS2520 cluster with all protocols licensed. Which two statements describe how to satisfy this request? (Choose two) A. enable high-availability shares and create LUNs with SMB B. purchase and implement FC switches C. enable the iscsi protocol and create and map the LUNs D. copy the data from the SMB shares to the LUNs Correct Answer: CD QUESTION 45 What are two valid LIF roles? (Choose two) A. cluster B. local C. management D. data Correct Answer: AD
20 QUESTION 46 Which LIF role must be configured before a cluster peering relationship is created? A. cluster LIF B. cluster-management LIF C. inter-cluster LIF D. node-management LIF Correct Answer: C QUESTION 47 You have a new requirement for storage at rest encryption and decide to use NetApp Storage Encryption (NSE) What is a requirement to encrypt the NSE drives? A. setup an external key management server and encrypt the drives B. setup encryption through SANtricity Storage Manager C. setup a Linux Kerberos server and encrypt the drives D. setup a clustered Data ONTAP security login API user and encrypt the drives Correct Answer: A QUESTION 48 Where do you apply a quota?
21 A. on an aggregate B. on a node C. on a volume D. on a disk Correct Answer: C QUESTION 49 When using Flash Pool intelligent caching, what is important to verify in your configuration? A. the number of PCIe slots in the FAS system that are available B. that only SSD aggregates are configured in the FAS system C. that SSDs are available as spares to add to the HDD aggregate D. that the HDDs are configured as spares to add to the SSD aggregate Correct Answer: C QUESTION 50 Your storage team is asked to audit all command line requests on a new install. They use the security audit modify -cliget on command. What is the results of using this command? A. The get commands and the set commands are logged to mgwd.log B. The get command are logged to the mgwd.log but the set commands are not logged C. The set command are logged to the mgwd.log but the get commands are not logged D. The get commands and the set commands are logged to the system console Correct Answer: A
22 QUESTION 51 What is the maximum number of Snapshot copies you can accumulate for a volume? A. 99 B. 255 C D. unlimited Correct Answer: B QUESTION 52 What is the SnapMirror type for vault relationships? A. DP B. DDP C. XDP D. TDP Correct Answer: C QUESTION 53 An unexpected network outage has occurred and you have lost access to an NFS share inside an SVM on your cluster. What is causing the problem? A. The broadcast domain does not have a failover policy defined
23 B. The MTU setting for the port is incorrect C. The failover group does not have the proper targets defined D. The current port is already hosting a LIF Correct Answer: A QUESTION 54 A customer has two SVMs joined to separate Active Directory domains. SVM1 is joined to domain AD1 and SVM2 is joined to domain AD2. The administrator enables Active Directory access to allow certain domain users access to the cluster using their Active Directory credentials. After enabling, some users report the inability to log into the cluster using their Active Directory credentials. What are the three reasons this happened? A. The user account belongs to the domain that is not used for cluster access authentication B. The cluster time is off by two minutes from the Active Directory time server. C. The authentication tunnels was deleted and access sessions were disconnected D. The Active Directory user account is not added to the cluster as a user E. The user is not a member of an Active Directory group that is allowed access tot the cluster Correct Answer: ADE
Exam Questions NS0-157
Exam Questions NS0-157 NetApp Certified Data Administrator, Clustered https://www.2passeasy.com/dumps/ns0-157/ 1. Clustered Data ONTAP supports which three versions of NFS? (Choose three.) A. NFSv4.1 B.
More informationOutline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9)
Outline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9) Cluster Module 1: ONTAP Overview Data Fabric ONTAP software Fabric layers The cluster Nodes High-availability pairs Networks
More informationNetapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ]
s@lm@n Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] https://certkill.com Topic break down Topic No. of Questions Topic 1: Volume
More informationONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview
ONTAP 9 Cluster Administration Course Code: Duration: 3 Days Product Page: https://digitalrevolver.com/product/ontap-9-cluster-administration-2/ This 3-day, instructor led course uses lecture and hands-on
More informationNS
NS0-157 Number: 000-000 Passing Score: 800 Time Limit: 120 min File Version: 1.0 Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Экзамен A QUESTION 1 What communication link
More informationNetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0.
NetApp Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which statement is true about a Data Protection (DP)-type SnapMirror destination
More informationNetworkAppliance NS NetApp Certified Data Administrator, ONTAP.
NetworkAppliance NS0-158 NetApp Certified Data Administrator, ONTAP http://killexams.com/pass4sure/exam-detail/ns0-158 Question: 67 What is the minimum number of disks required to create a data aggregate
More informationNS0-158 netapp. Number: NS0-158 Passing Score: 800 Time Limit: 120 min.
NS0-158 netapp Number: NS0-158 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 What are three causes of a storage failover partial giveback? (Choose three.) A. iscsi sessions are active. B. AutoSupports
More informationTestkings NS q
Testkings NS0-156 307q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 12.5 Network Appliance NS0-156 Data ONTAP Cluster-Mode Administrator Passed on 2-02-15 with an 890. Dump still
More informationNetwork- Appliance EXAM - NS NetApp Certified Implementation Engineer - SAN, Cluster-Mode. Buy Full Product
Network- Appliance EXAM - NS0-504 NetApp Certified Implementation Engineer - SAN, Cluster-Mode Buy Full Product http://www.examskey.com/ns0-504.html Examskey Network-Appliance NS0-504 exam demo product
More informationCluster Management Workflows for OnCommand System Manager
Clustered Data ONTAP 8.3 Cluster Management Workflows for OnCommand System Manager February 2016 215-10887_A0 doccomments@netapp.com Updated for 8.3.2 Table of Contents 3 Contents Contents of the Workflow
More informationCluster Management Workflows for OnCommand System Manager
ONTAP 9 Cluster Management Workflows for OnCommand System Manager June 2017 215-11440-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents OnCommand System Manager workflows...
More informationNS0-145 netapp
NS0-145 netapp Number: NS0-145 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 To automatically export volumes and directories on reboot, include them in the /etc/exports file. A. True B. False
More informationNS0-180 netapp
NS0-180 netapp Number: NS0-180 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 You want to create a data volume on aggr0 and you receive a message with the following warning: ''Warning: You are
More informationNS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507
NS0-507 Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-507 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Exam A QUESTION 1 You are asked to create a
More informationNetApp NS0-156_formatted
NetApp NS0-156_formatted Number: 000-000 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ NetApp NS0-156 Data ONTAP Cluster-Mode Administrator Version: 6.1 Exam A QUESTION
More informationCluster Management Workflows for OnCommand System Manager
ONTAP 9 Cluster Management Workflows for OnCommand System Manager August 2018 215-12669_C0 doccomments@netapp.com Table of Contents 3 Contents OnCommand System Manager workflows... 5 Setting up a cluster
More informationNetApp NS0-511 Exam. Volume: 65 Questions
Volume: 65 Questions Question No: 1 You are creating a SnapMirror relationship and custom SnapMirror policies are not defined. Which default policy will be applied in this scenario? A. MirrorAndVault B.
More informationNS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min.
NS0-191 netapp Number: NS0-191 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator notices that the clustered Data ONTAP 8.2.3 controllers are less responsive than normal. You use
More information7-Mode Transition Tool 2.2
7-Mode Transition Tool 2.2 Copy-Based Transition Guide For Transitioning to Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501
More informationNETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode
NETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode Duration: 5 Days Course Price: $5,850 Course Description Course Overview This training course is a 5-day boot camp with extended hours. The training
More informationNS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP
CertBus.com NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Pass NetApp NS0-506 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from:
More informationData ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led
Data ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led Course Description Welcome to the NetApp Data ONTAP 7-Mode Administration course. Data ONTAP 8 is the next generation data storage
More informationClustered Data ONTAP Administration (DCADM)
Clustered Data ONTAP Administration (DCADM) COURSE OVERVIEW: This course uses lecture and hands-on exercises to teach basic administration of clustered Data ONTAP. In this course you configure and manage
More informationClustered Data ONTAP Administration and Data Protection
Clustered Data ONTAP Administration and Data Protection COURSE OVERVIEW: This course uses lecture and hands-on exercises to teach basic administration of clustered Data ONTAP. In this course, you will
More informationNS Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: NS0-158
NS0-158 Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-158 NetApp Certified Data Administrator, ONTAP Version 1.0 Экзамен A QUESTION 1 Click the Exhibit button. You create
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : NS0-158 Title : NetApp Certified Data Administrator, ONTAP Vendor : Network Appliance Version : DEMO
More informationCopy-Based Transition Guide
7-Mode Transition Tool 3.2 Copy-Based Transition Guide For Transitioning to ONTAP February 2017 215-11978-A0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-based transition
More informationAccelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87)
Accelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87) COURSE OVERVIEW: This is a 5-day bootcamp that expands upon what students learned in the D7ADM course in order to prepare for the NCDA 7-mode certification
More informationExam Questions NS0-156
Exam Questions NS0-156 Data ONTAP Cluster-Mode Administrator http://www.2passeasy.com/dumps/ns0-156/ 1. What are the three types of Vservers in clustered Data ONTAP 8.2? (Choose all that apply) A. System
More informationNS0-511 netapp. Number: NS0-511 Passing Score: 800 Time Limit: 120 min.
NS0-511 netapp Number: NS0-511 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 A customer wants to maintain a single copy for both disaster recovery and backup on a secondary system. Which SnapMirror
More informationSMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server
ONTAP 9 SMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server November 2017 215-11158_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this
More informationOnCommand Unified Manager 6.1
OnCommand Unified Manager 6.1 Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web:
More informationSnapDrive 5.3 for UNIX
SnapDrive 5.3 for UNIX Administration Guide for Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
More informationExam Questions NS0-180
Exam Questions NS0-180 NetApp Certified Storage Installation Engineer, Clustered Data ONTAP https://www.2passeasy.com/dumps/ns0-180/ 1. Which three types of interface groups are supported on NetApp storage
More informationOnCommand Unified Manager 6.1 Administration Guide
IBM System Storage N series OnCommand Unified Manager 6.1 Administration Guide SC27-6627-00 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information, help, and
More informationSnapDrive for UNIX
SnapDrive 5.2.1 for UNIX Installation and Administration Guide For Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationAll Flash FAS SAN-Optimized Configuration
Technical Report All Flash FAS SAN-Optimized Configuration Michael Peppers, NetApp June 2016 TR-4480 Abstract This technical report provides details about the SAN-optimized configuration for NetApp All
More informationONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9)
ONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9) COURSE OVERVIEW: This 5-day course comprises the 3-day ONTAP 9.3 Cluster Administration (ONTAP9ADM) followed by the 2-day ONTAP 9.3
More informationClustered Data ONTAP 8.3
Clustered Data ONTAP 8.3 FC Configuration for ESX Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)
More informationClustered Data ONTAP 8.3 Administration and Data Protection Workshop
NA-CDOTDP-WS Clustered Data ONTAP 8.3 Administration and Data Protection Workshop Prerequisites A basic understanding of system administration with UNIX or Windows is recommended as well as the web-based
More informationData Protection Guide
SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationCluster Management Using OnCommand System Manager
ONTAP 9 Cluster Management Using OnCommand System Manager November 2017 215-12668_A0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Understanding System Manager... 15 Icons
More informationIT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com
IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com Exam : NS0-102 Title : NetApp(ASAP) Accredited Storage Architect Professional Version : DEMO 1 / 7 1. Which
More informationInfinite Volumes Management Guide
ONTAP 9 Infinite Volumes Management Guide September 2016 215-11160_B0 doccomments@netapp.com Visit the new ONTAP 9 Documentation Center: docs.netapp.com/ontap-9/index.jsp Table of Contents 3 Contents
More informationAccelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led
Accelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led Course Description Prepare for success when taking the NS0-155 NetApp Certified Data Management 7-Mode Administrator
More informationNS0-171.network appliance
NS0-171.network appliance Number: NS0-171 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator is deploying a FlexPod solution for use with VMware vsphere 6.0. The storage environment
More informationNetapp.Examsheets.NS0-156.v by.Luger.154q. Exam Code: NS Exam Name: Data ONTAP Cluster-Mode Administrator
Netapp.Examsheets.NS0-156.v2014-01-15.by.Luger.154q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 20.5 http://www.gratisexam.com/ Exam Code: NS0-156 Exam Name: Data ONTAP Cluster-Mode
More informationVolume Disaster Recovery Express Guide
ONTAP 9 Volume Disaster Recovery Express Guide December 2017 215-11188_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster
More informationNDMP in Clustered Data ONTAP for Tape Backup Software Applications
Technical Report NDMP in Clustered Data ONTAP for Tape Backup Software Applications Subhash Athri, NetApp June 2015 TR-4376 TABLE OF CONTENTS 1 NDMP Backups... 3 1.1 Tape Backup Topologies in Clustered
More informationFlexArray Virtualization
Updated for 8.3.2 FlexArray Virtualization Installation Requirements and Reference Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support
More informationNetapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ]
s@lm@n Netapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ] Question No : 1 Which command is used to set the configuration of an Ethernet network interface? A. ifconfig
More informationData ONTAP 8.2. MultiStore Management Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.
Updated for 8.2.2 Data ONTAP 8.2 MultiStore Management Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-157 Title : NetApp Certified Data Administrator, Clustered Data ONTAP Vendor : Network Appliance Version : DEMO
More informationVendor: IBM. Exam Code: Exam Name: IBM Midrange Storage Technical Support V3. Version: Demo
Vendor: IBM Exam Code: 000-451 Exam Name: IBM Midrange Storage Technical Support V3 Version: Demo QUESTION NO: 1 On the Storwize V7000, which IBM utility analyzes the expected compression savings for an
More informationSAN Configuration Guide
ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi
More informationData ONTAP 7-Mode Administration
Data ONTAP 7-Mode Administration Cursusduur: 5 Dagen Cursuscode: D7ADM Beschrijving: This five-day instructor-led course enables you to perform basic support and administrative functions on a NetApp storage
More informationNFS Configuration Express Guide
ONTAP 9 NFS Configuration Express Guide December 2017 215-11172_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 NFS configuration workflow...
More informationData ONTAP 7-Mode Administration (D7ADM)
Data ONTAP 7-Mode Administration (D7ADM) COURSE OVERVIEW: Welcome to the NetApp _ Data ONTAP _ 7-Mode Administration course. Data ONTAP 8 is the next generation data storage operating system from NetApp.
More informationNetApp Encryption Power Guide
ONTAP 9 NetApp Encryption Power Guide February 2017 215-11633-D0 doccomments@netapp.com Updated for ONTAP 9.1 Table of Contents 3 Contents Deciding whether to use the NetApp Encryption Power Guide...
More informationThis course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating system.
Accelerated NCDA Boot Camp Data ONTAP 8.0 7-Mode (ANCDABC87) Who should attend This course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating
More informationData Protection Guide
SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationCopy-Free Transition Guide
7-Mode Transition Tool 3.0 Copy-Free Transition Guide For Transitioning to ONTAP September 2016 215-11373_B0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-free transition
More informationNetapp.Actualtests.NS0-156.v by.LIZZIE.154q
Netapp.Actualtests.NS0-156.v2014-05-26.by.LIZZIE.154q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 20.5 http://www.gratisexam.com/ Exam Code: NS0-156 Exam Name: Data ONTAP Cluster-Mode
More informationA. Both Node A and Node B will remain on line and all disk shelves will remain online.
Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in
More informationClustered Data ONTAP 8.3
Updated for 8.3.1 Clustered Data ONTAP 8.3 Using All Flash FAS with Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support
More informationATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation
ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This
More informationClustered Data ONTAP 8.3 Update 2, IPspaces. Self-paced Lab NETAPP UNIVERSITY. NetApp University - Do Not Distribute
NETAPP UNIVERSITY Clustered Data ONTAP 8.3 Update 2, IPspaces Self-paced Lab Course ID: STRSW-SPL-CDOT83UPD2 Content Version: 1.0 ATTENTION The information contained in this course is intended only for
More informationClustered Data ONTAP 8.3
Clustered Data ONTAP 8.3 Volume Disaster Recovery Preparation Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationFC Configuration for ESX Express Guide
ONTAP 9 FC Configuration for ESX Express Guide March 2017 215-11179-C0 doccomments@netapp.com Updated for ONTAP 9.1 Table of Contents 3 Contents Deciding whether to use this guide... 4 FC configuration
More informationNetApp FAS8000 Series
Datasheet NetApp FAS8000 Series Respond more quickly to changing IT needs with unified scale-out storage and industry-leading data management KEY BENEFITS Support More Workloads Run SAN and NAS workloads
More informationEXAM - NS NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP. Buy Full Product.
Network Appliance EXAM - NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Buy Full Product http://www.examskey.com/ns0-506.html Examskey Network Appliance NS0-506 exam demo
More informationNetApp Encryption Power Guide
ONTAP 9 NetApp Encryption Power Guide December 2017 215-11633_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use the NetApp Encryption Power Guide...
More informationExam Questions ns0-507
Exam Questions ns0-507 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP https://www.2passeasy.com/dumps/ns0-507/ 1. Which SAN topology is shown in the exhibit? A. Core-edge B. Star
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-504 Title : NetApp Certified Implementation Engineer - SAN, Cluster-Mode Vendor : Network Appliance Version : DEMO
More informationClustered Data ONTAP 8.2 High-Availability Configuration Guide
IBM System Storage N series Clustered Data ONTAP 8.2 High-Availability Configuration Guide SC27-6276-02 Table of Contents 3 Contents Preface... 7 About this guide... 7 Supported features... 7 Websites...
More informationData ONTAP Mode Release Notes
IBM System Storage N series Data ONTAP 8.0.4 7-Mode Release Notes GA32-0723-15 Contents Data ONTAP 8.0.4 7-Mode Release Notes.................... 1 Changes introduced since Data ONTAP 8.0....................
More informationClustered Data ONTAP 8.3: A Proven Foundation For Hybrid Cloud
Clustered Data ONTAP 8.3: A Proven Foundation For Hybrid Cloud Jay Goldfinch Technical Marketing Engineer November 2014 Mike McNamara Senior Manager, Product Marketing As the NetApp clustered Data ONTAP
More informationSUPPORTING CLUSTERED DATA ONTAP: NODE MANAGEMENT
OFFERED BY: CUSTOMER SUCCESS OPERATIONS KNOWLEDGE MANAGEMENT ADVANCED TECHNICAL TRAINING SUPPORTING CLUSTERED DATA ONTAP: NODE MANAGEMENT EXERCISE GUIDE Content Version: 0.9 This page left intentionally
More informationNetworkAppliance NS Data ONTAP Mode Administrator.
NetworkAppliance Data ONTAP 8.0 7-Mode Administrator http://killexams.com/exam-detail/ QUESTION: 137 NetApp recommends that Fibre Channel switches that have both disk and tape connected to them should
More informationOnCommand System Manager 3.1 RC1 Release Notes for Clustered Data ONTAP
IBM System Storage N series OnCommand System Manager 3.1 RC1 Release Notes for Clustered Data ONTAP SC27-6427-01 Contents System Manager 3.1 RC1 Release Notes...................... 1 Understanding System
More informationSMB/CIFS Configuration Express Guide
ONTAP 9 SMB/CIFS Configuration Express Guide November 2017 215-11170_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 SMB/CIFS configuration
More informationSnapCenter Software 4.0 Concepts Guide
SnapCenter Software 4.0 Concepts Guide May 2018 215-12925_D0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use the Concepts Guide... 7 SnapCenter overview... 8 SnapCenter architecture...
More informationData ONTAP 8.2 Storage Management Guide For 7-Mode
IBM System Storage N series Data ONTAP 8.2 Storage Management Guide For 7-Mode SC27-5928-02 Table of Contents 3 Contents Preface... 17 About this guide... 17 Supported features... 17 Websites... 18 Getting
More informationVirtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere
Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationFlexArray Virtualization Implementation Guide for NetApp E-Series Storage
ONTAP 9 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage June 2017 215-11151-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents Where to find information
More informationLearning About Cloud Manager and ONTAP Cloud
OnCommand Cloud Manager 3.3 Learning About Cloud Manager and ONTAP Cloud March 2018 215-12279_E0 doccomments@netapp.com Updated for Cloud Manager 3.3.3 Table of Contents 3 Contents OnCommand Cloud Manager
More informationAbstract. Data Classification. Technical Report. Roy Scaife, NetApp Version March 2016 TR-4375
Technical Report Roy Scaife, NetApp Version 1.2.1 March 2016 TR-4375 Abstract This document provides technical information about NetApp MetroCluster software in the NetApp Data ONTAP 8.3.2 operating system.
More informationSnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP
Technical Report SnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP Amit Prakash Sawant, NetApp December 2013 TR-4015 SnapMirror Configuration and Best Practices This document describes
More informationFC Configuration for Windows Express Guide
ONTAP 9 FC Configuration for Windows Express Guide December 2017 215-11173_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 FC configuration
More informationClustered Data ONTAP Release Notes
IBM System Storage N series Clustered Data ONTAP 8.2.3 Release Notes SC27-6290-05 Contents Clustered Data ONTAP 8.2.3 Release Notes.................... 1 Changes introduced since Data ONTAP 8.2....................
More informationClustered Data ONTAP 8.2
Clustered Data ONTAP 8.2 SAN Express Setup Guide for 62xx Systems NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888)
More informationData Fabric Solution for Cloud Backup Workflow Guide
Data Fabric Solutions Data Fabric Solution for Cloud Backup Workflow Guide Using ONTAP, SnapCenter, and AltaVault June 2017 215-11811_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether
More informationDisks and Aggregates Power Guide
ONTAP 9 Disks and Aggregates Power Guide November 2017 215-11204_F0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 6 Aggregate creation
More informationData ONTAP 8.2. System Administration Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.
Updated for 8.2.1 Data ONTAP 8.2 System Administration Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationNetapp Exam NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Version: 6.0 [ Total Questions: 65 ]
s@lm@n Netapp Exam NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Version: 6.0 [ Total Questions: 65 ] https://certkill.com Netapp NS0-506 : Practice Test Question No : 1
More informationNetApp Encryption Power Guide
ONTAP 9 NetApp Encryption Power Guide June 2018 215-11633_L0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use the NetApp Encryption Power Guide... 5 Configuring NetApp Volume
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : NS0-507 Title : NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Vendor : Network
More informationNetApp FAS3200 Series
Systems NetApp FAS3200 Series Get advanced capabilities in a midrange storage system and easily respond to future expansion KEY benefits Best value with unmatched efficiency. The FAS3200 series delivers
More informationData ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode
IBM System Storage N series Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode This Release Candidate publication is provided in conjunction with a Data ONTAP 8.1.2 RC code
More information