1 Technical Description Network Interface Card for NTP- and udp/time protocol version
2 Company Info hopf_elektronik Nottebohmstr. 41 Post box Lüdenscheid Lüdenscheid tel.: ++49 (0)2351 / fax: ++49 (0)2351 / internet: info@hopf-time.com version page 2
3 Table of Contents CONTENTS Page 1 Network Interface Card 4 2 Hardware Installation Requirements Controller Controller Setup Steps to configure the controller The following shows a typical setup session Network Parameters Network Clock Parameters 6 3 Time distribution formats NTP udp/time Proprietary protocol Network connectors 8 4 Serial interface LED status and error codes 9 5 Maintenance and testing Monitor commands Firmware download serial Firmware download from host 11 6 Technical data CPU, Memory, Controllers: Serial interface Network Interface: Power Supply: Status Indication Token Ring Version 12 version page 3
4 1 Network Interface Card The hopf_network Radio Clock is a board which receives standard world time information from the hopf_gps or DCF77 system 7000/1 bus, and makes this information available to computers, controllers and other equipment needing correct time information. The time information is distributed over the network interface and the Network Radio Clock supports the most popular time distribution protocols, NTP, time/udp plus an easy-to-integrate proprietary protocol, which supports broadcasting. 2 Hardware Installation Requirements 2.1 Controller The controller can be installed anywhere in the network and has to be connected through the appropriate interface and cables. 2.2 Controller Setup Before connecting the controller the first time to the LAN, it has to be configured, preferably through its serial port and a terminal or terminal emulation software on a PC. Connecting the controller to the network with wrong settings might produce network faults, especially if a wrong Token Ring ring rate or duplicate IP address is set Steps to configure the controller 1. An ASCII terminal or PC with a terminal emulation is connected to the first serial port (CN1) of the Controller. The terminal must be configured to 9600 Baud, no parity, 8 bit, 1 or 2 stop bits. 2. To enter configuration mode, the controller must be reset (by pushing the reset switch, if installed, or by cycling the power). Immediately after power-up, the controller performs a self test and lights all three status LED s. 3. Within about one second, the red LED starts blinking and an asterisk (*) is sent out over the serial line. Three small x characters (HEX value 120h) must be sent at that time. The controller responds with Identification data (serial number, software version etc.) and asks for a <CR> (HEX 0Dh) to enter setup mode. version page 4
5 2.2.2 The following shows a typical setup session *xxx *** FunkUhr atomic reference clock *** Serial Number Software Version (980609) Press Enter to go into Setup Mode After <CR> is entered, the actual settings are displayed and parameters can be changed. *** basic parameters Hardware: Ethernet TPI IP addr , no gateway set *** Funkuhr parameters Antenna type: Hopf 6021 UDP datagram disabled Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 0 0 <- start basic setup Ethernet Interface AUI (N) N IP Address : (150).(100).(100).(021) Set Gateway IP Adress (N) N Netmask: Number of Bits for Host Part (0=default) (00) Change telnet config password (N) N *** basic parameters Hardware: Ethernet TPI IP addr , no gateway set *** Funkuhr parameters Antenna type: Hopf 6021 UDP datagram disabled Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 1 Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 1 1 <- start funkuhr setup Antenna Type (0=DCF77,1=Trimble,2=TRAK,3=Hopf 6021) Enter UDP Port (hex 0000), 0 to disable Send Block every n minutes (001) Send UDP broadcast (N) N Enter up to eight target addresses for UDP block, to end #1 : (000).(000).(000).(000) *** basic parameters Hardware: Ethernet TPI IP addr , no gateway set version page 5
6 *** Funkuhr parameters Antenna type: Hopf 6021 UDP datagram disabled Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 0 save and exit The controller can be configured over a Telnet connection to port 9999 (assuming the network parameters are set correctly and it is connected to the network). 2.3 Network Parameters Within the basic parameters, the controllers IP address and network interface selection are most important. Make sure that a valid IP address for the network is entered and the right network interface is selected (model dependent) before connecting to the network. The default gateway IP address has to be set to the default router or gateway if targets outside of the logical network have to be adjusted or the controller must be reached by computers from outside the logical network. The netmask setting is important if the standard IP addressing scheme (Class A/B/C) is not used (active sub-netting). The netmask is entered for historical purposes as the # of host bits. Zero means standard Class A/B/C. Some examples: Netmask # host bits The Telnet password prevents unauthorized access to the setup menu over the network (through the serial interface, the password is not required). It s maximum length is 4 characters. Token Ring Version: The Ring Speed has to be set by Jumper (installed: 16Mbit, open: 4Mbit) to avoid a configuration error by accident. An administered address can be entered in the dialog. 2.4 Network Clock Parameters The network parameters control the operation of the Server. The UDP port selects the port number for the proprietary protocol. To be compatible with PC software and KABA Benzing Terminals, it should be set to 77FF (hexadecimal). The remaining parameters cover how often the data block should be sent (starting at every full hour), if it should be sent as broadcast, and, additionally, up to eight target addresses can be defined to which the data block should be sent. NTP and udp/time port numbers are fixed to the values defined in RFC-37 and RFC-123 respectively. If the authentication option is enabled, up to seven md5 or DES keys can be entered (key numbers 1..7). All key input must be done in hexadecimal, and md5 key length is limited to eight char acters. When leaving the setup mode (by selecting function 9), the parameters are stored in nonvolatile memory and the controller goes through a reset. version page 6
7 3 Time distribution formats After the Network Radio Clock receives valid time information, it distributes the standard time via different services to the systems connected to the LAN. 3.1 NTP The controller operates in server mode. Symmetric operation modes are not supported. It understands NTP Version 1, 2, and Version 3 frames, and optionally supports authentication via DES and MD5 cryptographic checksums. If authentication is not used, the controller can typically be used for hundreds of clients without overloading it. Authentication requires typically 40 ms for checking and generating the cryptograms, which is covered and averaged out by the protocol. The Network Radio Clock supports full SNTP and all NTP functions required for reliable server operation. Functions not required for server operation are not implemented. 3.2 udp/time This rather old protocol has a resolution of one second, and is used by older UNIX systems and a variety of PC and technical equipment solutions. 3.3 Proprietary protocol This has been developed to ease the setting of KABA Benzing Terminals and controllers which are connected to the networks with BETA and BETOR network adapters. Also suitable for Windows 3.1, 3.11 PC s and other systems which do not support NTP. A simple C program sample source works on UNIX and VMS systems and can easily be ported to others. In central Europe, it can be used to facilitate automatic daylight savings switching, as the Network Radio Clock knows the CET rule (and DCF77 provides an indicator). This Protocol simply sends out a UDP block in a programmable interval as broadcast or direct to targets. The port number can be set, but it is necessary to set it to 77FF(hex) for operation with KABA Benzing equipment and the provided software. UDP Block contents: UDP Data offset Contents ASCII string, containing CET/CST Year (00..99) Month (01..12) Day (01..31) Hour (00..23) Min. (00..59) Sec. always Day of week (1-Mo, 2-Tue..) 13 DST active (0-no,1-yes) 14 String termination, \ CET/CST time in UNIX format 32bit value, network byte order seconds since 1/1/ GMT time in UNIX format 32bit value, network byte order seconds since 1/1/1970 version page 7
8 This data can be used to synchronize to about one second accuracy, as the block is sent out at the beginning of the first second of every minute. This interval can be changed. The controller can be configured with various methods, remote or locally. To configure locally, access to the first (or only) serial port and an ASCII terminal is necessary. To configure over the network, a Telnet connection to port 9999 must be established. The controller configuration is stored in nonvolatile memory. The configuration can be changed at any time. 3.4 Network connectors Depending on the model, the Network Radio Clock features 10-Base 2, 10-Base T and/or AUI connectors. Selection of the active connection is done by software. The transceiver interface can supply 12 V, up to 300 ma. If more power is needed (i.e. for a fiberoptic transceiver), an external transceiver power supply must be used. version page 8
9 4 Serial interface The setup menu is available at the (first or only) serial port at the controller. Pin-out of the RJ-45 connector for the 19 rack version: Pin RS 232 RS485 1 Shield Shield 2 CTS (input) TXD 3 TXD (output) RXD + 4 DTR (output) RXD 5 Signal GND TXD + 6 RXD (input) Signal GND 7 CD (input) 8 RTS (output) Signal GND 4.1 LED status and error codes After the initial self test phase, where all status LEDs should be lit, the LEDs indicate the status of the Network Radio Clock. Green LED on: synchronized to the time signal, correct reception of time data. Green LED flashing 50% duty cycle: Some information received, but not yet synchronized reliable. Red LED stable on or flashing 50%, green LED flashing: 1x: EPROM-checksum error 2x: RAM-error 3x Network controller error 4x: E²PROM checksum error or bad 5x: I P address already used on network version page 9
10 5 Maintenance and testing To enter monitor mode, the same principle as setting the parameters is used (see Controller Setup). Instead of entering three x, x x 1 is keyed in. The controller will respond with a special prompt. Network functions are needed for some diagnostics commands and it may take up to 20 seconds until the network part of the controller is initialized and the prompt is displayed. This is especially true if a token ring is empty or a ring simulator is used. For a simple ring simulator, see the appendix. To start the monitor mode without network functions, enter xx2 (new function from Version 2.05 up). Please note : A Token Ring controller needs a working network connection to enter monitor mode 5.1 Monitor commands The following commands are available in the monitor mode. Many commands have an IP address as an optional parameter (x.x.x.x). If it is given, the command is applied to a remote controller with that IP address. If no IP address is given, the command is executed locally. All commands must be given in capital letters, only blanks are accepted as white space between parameters. DL SF x.x.x.x VS (x.x.x.x) GC (x.x.x.x) SC (x.x.x.x) PI x.x.x.x QU Firmware download to the Controller Send Firmware to Controller with IP x.x.x.x Query software header record (16 Byte). Get configuration as HEX records (120 Bytes) Set configuration from HEX records (120 Bytes) Check with ICMP packages (PING) if IP x.x.x.x is alive reachable. Quit - exit diagnostics mode command result codes: 0 OK, no error 1 no answer from remote device 2 cannot reach remote device or does not answer 8 wrong parameter(s) 9 invalid Command 5.2 Firmware download serial Downloading is done in Monitor mode. Once in Monitor mode, the DL command is given. The node now waits for the firmware image in "HEX" format, which must be sent complete through the serial interface. When the end record is received, the controller checks the integrity of the firmware image and then starts programming the new firmware in the Flash prom. After complete reprogramming, the controller resets. WARNING! A loss of power while reprogramming will result in a corrupt program image and a nonfunctional controller. version page 10
11 5.3 Firmware download from host To download a new firmware from a computer to a CoBox, a working TFTP implementation is needed. For Win95 systems, a download program is available from hopf_on request. The parameters to send the firmware are: Target filename: 3Q Transfer mode: binary The file to be downloaded must be the "ROM" image, not the "HEX" version. File size should be or bytes. WARNING! A loss of power while reprogramming will result in a cor -rupt program image and a nonfunctional controller. version page 11
12 6 Technical data 6.1 CPU, Memory, Controllers: V.40 CPU, 10 MHz clock Z85C30 SCC Serial Controller National Semiconductor DP839xx Ethernet Controller or IBM Tokenring OEM module (starting 1997: TMS340 chipset) 128kByte RAM, 128k-512kByte Flash PROM 256 Byte E²PROM for parameter storage 6.2 Serial interface External 19 Rack OEM module Connector SubD25 RJ-45 pin strap Speed RS-232/485 sw software jumper TTL level only 6.3 Network Interface: 10-Base T interface 6.4 Power Supply: 5 V, 600 ma max, +12 V, -12 V 6.5 Status Indication Three colored LED s. 6.6 Token Ring Version Network Interface The Token Ring controller has a standard D-Shell 9 pin female connector to be connected to standard token ring drop cables. The ring interface speed is configured by a jumper to prevent accidental misconfiguration. After opening the case, a jumper must be removed for 4 Mbit operation (delivery standard is jumper installed, 16 Mbit). version page 12
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED
More informationNCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationNCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationNET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2
NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
More informationWiBox 2100 Quick Start Guide
WIBOX 2100 Quick Start Guide 2004 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-367 07/04 WIBOX 2100 QUICK START CONTENTS What s in the Box..........................................................2
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationTechnical Description. Special Software FG (for System 4465) version
Technical Description Special Software FG446580-82 (for System 4465) version 01.00 07.04.99 CONTENTS Page 1 General Information 3 2 Time Offset 3 2.1 Time Offset with Special Software FG446580 3 2.2 Time
More informationWiSpan Quick Start Guide
Quick Start Guide 2008 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-462 Rev. B 06/08 QUICK START CONTENTS What s In the Box..........................................................2
More informationACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter
APCON100 series Operation Manual RS-232 to Ethernet Converter Page 1 of 24 APCON100 series Operation Manual Index Chapter 1 Specifications 2 Chapter 2 Introduction 3 Chapter 3 Easy Installation 4 Chapter
More informationLM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections
TECHNOLOGIES Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections Android XP Vista Part No Bluetooth Features Supports 3 simultaneous Bluetooth SPP Connections CSR Bluecore 04
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informatione-net TCP/IP Converters
e-net TCP/IP Converters E-P132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 6 Product Specifications
More informationUser s Manual. INAT echolink Serial / Industrial Ethernet- Converter. Manual-Version e
User s Manual Serial / Industrial Ethernet- Converter Manual- 2 Copyright The contents of this manual an the related configuration software are the property of the INAT GmbH. This material is subject to
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationThe possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005.
5.2 CP260 5.2.1 General Information The CPU is inserted in the main rack directly next to the power supply module. It requires two slots. Only the status LEDs can be seen with the module door closed. The
More information2004 Copyright BlackBox is a trademark of BlackBox. All rights reserved Rev. A 01/04. LES2700A-10 Quick Start Guide
2004 Copyright BlackBox is a trademark of BlackBox. All rights reserved. 900-334 Rev. A 01/04 Quick Start Guide QUICK START CONTENTS Pinouts................................................................2
More informationTCP/IP Converter. EX-9132 Operation Manual for 8051 Series
TCP/IP Converter EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
More informationSERIAL TO ETHERNET CONVERTER E-P User Manual
SERIAL TO ETHERNET CONVERTER E-P132-100 User Manual 1 Table of Contents Introduction... 4 Overview.. 5 Package Checklist 6 Block Diagram 7 Product Features...8 Product Specifications 9 Converter Description
More informationLM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections
Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections Product: Features Server Features Supports 0/00 Mbps Ethernet Supports RS-3, RS-4 and RS-485 serial interface Supports LAN
More informationSite Ethernet Interface Installation Manual
Site Ethernet Interface Installation Manual PK XXXX 10/03 1 of 22 Second Edition A publication of Kaba Ilco, Inc. 7301 Decarie Blvd. Montreal, Quebec Canada H4P 2G7 Printed in Canada, 2002 Copyright by
More informationPortStore. Ethernet - RS232 Buffer 512 or 2048 kb. RS-232 Serial line buffer controlled over Ethernet interface.
PortStore Ethernet - RS232 Buffer 512 or 2048 kb RS-232 Serial line buffer controlled over Ethernet interface. Typical applications A branch telephone exchange is located in the basement of a building.
More informationConettix ITS-D6682-INTL
Conettix ITS-D6682-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationEthernet Serial Server
Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4
More informationSSE232-LE Serial Server- User s Manual
www.exemys.com Rev.6 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information
More informationCanlan INSTALLATION MANUAL
Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...
More informationFics-RT1. User s Manual
Fics-RT1 User s Manual Contents 1: Overview... 1 2: Terminal Specifications... 1 2-1: Standard Specifications... 1 2-2: Customer Defined Features:... 1 3: Terminal RS232C Communication Link Details...
More informationUSR-TCP Hard version: V2.0 File version: V
Serial Device Server - RS232/RS485 to Ethernet converter USR-TCP232-300 Hard version: V2.0 File version: V1.1 2011-8-17 Serial Device Server - RS232/RS485 to Ethernet converter is an Equipment for convert
More informationChapter 5: Communications 5 1 SR55 Communications Overview 5 2
Chapter 5 Table of Contents Chapter 5: Communications 5 1 SR55 Communications Overview 5 2 Modbus Serial Communications Overview 5 2 Modbus TCP Network Communications Overview 5 2 EtherNet/IP Network Communications
More informationECOV-110 User s Manual
ECOV-110 User s Manual 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ECOV-110 Firmware upgrade ECOV-110 1. ECOV-110 Product Introduction: 1.1.
More informationOperation Manual of EX-9132C-2. Serial to TCP/IP Converter
Operation Manual of EX-9132C-2 Serial to TCP/IP Converter Version 1.1.0, 25th Jan. 2010 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 6 Product Specifications
More informationOperation Manual of EX9132CST-Series
Operation of EX9132CST-Series Serial to TCP/IP Converter (EX9132CST-2/ EX9132CST-RS485/ EX9132C-RS232) Version 1.0.0. 30.03.2017 Table of Contents 1 Introduction... 4 2 Overview... 5 2. 1 Package Checklist...
More informationInstallation and User Guide
Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol
More informationRN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL
RN-WIFLY-EVAL-UM WiFly Evaluation Kit 0 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-.0 Version.0 //0 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks
More informationMotortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision
Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803
More informationUDS1100 User Guide Part Number Revision D August 2008
UDS1100 User Guide Part Number 900-417 Revision D August 2008 Copyright & Trademark Contacts 2006, 2007, 2008 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or
More informationDGH A3000 Configuration Guide For use with DGH Modules
DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation
More informationSerial to Ethernet Converter
Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem
More informationNordField Electronics
NordField Electronics XS1000 TCP/IP to RS232/422/485 Device Server Overview and quick info sheet 3.0. Hardware Installation & Initial Setup 3.1 RS-232 Configuration:(DB9 Male) (DB9Male) Signal I/O PIN2
More informationMGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual
MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000
More informationINDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter
Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring
More informationAppendix A Cable Pinouts
Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules
More informationGE s Automation & Controls
GE s Automation & Controls Programmable Control Products VersaMax Serial to Ethernet Adapter User Manual GFK-1852B March 2016 Preface Warnings, Cautions, and Notes as Used in this Publication GFL-002
More informationConettix ITS-D6682-UL
Conettix ITS-D6682-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-UL Installation Guide Contents Contents 1.0 Introduction...3 1.1 Network Interface... 3 1.2 Serial Interface... 3
More informationVolume 1 Hardware Manual
Volume 1 Hardware Manual Version 1.6 Copyright 2003 egnite Software GmbH. All rights reserved. egnite makes no warranty for the use of its products and assumes no responsibility for any errors which may
More informationInstalling the Cisco Unified Videoconferencing 3545 MCU
CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)
More informationTRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6
TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed September 1 2015 Rev 1.6 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More information11 Serial Communications
11.1 COMMUNICATIONS PACKAGES There are a number of communication packages that can be used with the Quantum III to facilitate setup, record parameter data, view internal activity on a soft-scope and permit
More information- Data exchange using configuration-based and logic-based Ethernet Global Data
May 2003 PACSystems RX7i The IC698ETM001 Interface module provides high performance communications for the RX7i control system. The Interface provides TCP/IP communications with other GE Fanuc control
More informationEZL-400S User s Manual
EZL-400S User s Manual Version 1.1 Sollae Systems Inc. -Table of Context - 1. OVERVIEW... - 4-1.1. OVERVIEW...- 4-1.2. COMPONENTS...- 5-1.3. SPECIFICATIONS...- 5-1.3.1. Power... - 6-1.3.2. Dsub Connector...
More informationCable Pinouts. SRP I/O Module
Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4
More informationFERGUSON BEAUREGARD. RTU-5000 Configurator User Manual
FERGUSON BEAUREGARD RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual The Ferguson Beauregard RTU-5000 Configurator program and manuals are Copyright 1997-2004 by
More informationQuick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.
LES302A LES302A-KIT LES302AE-KIT 2-Port 10/100 Device Server RS-232/422/485 DB9 M Quick Start Guide Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network. Customer Support Information
More informationTotal Control System Application Guide
Total Control System Application Guide PPP Dial-in / IP Network / Channelized T1 HiPer ARC / HiPer DSP Part No. 1.024.1804-00 Version Number 1.0 Total Control System Application Guide Point-to-Point Protocol
More informationCF2SCSI Disk Bridge User Guide
CF2SCSI Disk Bridge User Guide Overview The CF2SCSI bridge PCB is a general purpose SCSI bridge PCB for a Compact Flash (CF) Card. A regular CF card is plugged into the 3M CF socket at the end of the PCB
More informationTRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3
TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:
More informationDocument Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index
Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration
More informationLevelOne. User Manual. WAP Mbps PoE Wireless AP V3.0.0
LevelOne WAP-0005 108Mbps PoE Wireless AP User Manual V3.0.0 i TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 FIGURE 1: WIRELESS ACCESS POINT... 1 FEATURES OF YOUR WIRELESS ACCESS POINT... 1 Security Features...
More informationNE-4100 Series Serial Command Mode User s Guide
NE-4100 Series Serial Command Mode User s Guide www.moxa.com/product First Edition, September 2004 Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 www.moxa.com support@moxa.com.tw
More informationDocument Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter
Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default
More informationLM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:
LM300 Manager User Manual Document Version: 1.1 LM300 Firmware Version: 2.0.1 Bluetooth Firmware Version: 7.5.4279 LM300 Bluetooth Ethernet Access Point LM300 Manager User Manual i Revision Date Description
More informationEMERALD-MM-8P. 8-Channel Software Programmable Protocol. Serial Port PC/104 TM Module. User Manual V1.20
EMERALD-MM-8P 8-Channel Software Programmable Protocol Serial Port PC/104 TM Module User Manual V1.20 Copyright 2005, 2008, 2011 DIAMOND SYSTEMS CORPORATION 555 Ellis Street Mountain View, CA 94043 Tel
More informationCONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS
CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS This configuration guide provides programming information for the DL-PC (ISA) and DL-STD (STD 80 and 32) Remote I/O Link applications.
More informationxpico 110 Wired Device Server Module User Guide
xpico 110 Wired Device Server Module User Guide Part Number 900-783-R Revision B December 2017 Intellectual Property 2017 Lantronix. All rights reserved. No part of the contents of this publication may
More informationUpgrading the Software
APPENDIX B Upgrading the Software You can upgrade your software in the following ways: From the Cisco IOS command-line interface (CLI) From the ROM monitor Cisco recommends upgrading your software from
More informationSoekris Engineering. net4801 series boards and systems. User s Manual
Soekris Engineering net4801 series boards and systems. User s Manual Vers 0.05 April 10, 2004 Table of Contents 1 INTRODUCTION...4 1.1 Overview... 5 1.2 Bus Expansion... 5 1.3 Multi-IO Controller... 6
More informationWM-120. Serial to Ethernet Module. Serial to Ethernet Module. User Manual. Version 1.0. Infosystem Technology Corporation, Ltd.
W M - 1 2 0 User Manual Version 1.0 Infosystem Technology Corporation, Ltd. Index 1. Disclaimers... 1. A. Warranty... 2. B. Trademark... 2. 2. Product Information... 3. A. Introduction... 3. B. Features...
More informationMultiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual
Multiplexer FMUX/SAT 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode Installation and Operations Manual Document version: 1.7E / 06.09.2006 FMUX/SAT Multiplexer Safety Precautions
More informationGPORT104 User s Manual
GPORT104 User s Manual Beijing Golden Global View Co., Ltd. RAYON Technology Co., Ltd. Version( V 1.01) Contents I. Product Introduction II. Features III. Technical Specifications IV. Hardware Installation
More informationUSR-TCP Hard version: V1.1 File version: V
RS232/RS485 to convert module USR-TCP232-24 Hard version: V1.1 File version: V1.2 2011-08-18 RS232/RS485 to convert module is an Equipment for convert TCP or UDP socket data to RS232 or RS485, easy to
More informationPCard2SCSI Flash-Tape User Guide
PCard2SCSI Flash-Tape User Guide Overview The PCard2SCSI bridge PCB is a general purpose SCSI bridge PCB for a PCMCIA mounted Flash Card. A regular CF card can be plugged into the PCMCIA eject header using
More informationZIC2410 User Guide Device-Programmer Software Manual
ZIC2410 Series ZIC2410 User Guide Device-Programmer Software Manual 0005-05-08-00-001 (Rev B) Table of Contents 1 INTRODUCTION & PURPOSE... 3 1.1 DEFINITIONS... 3 1.2 REFERENCED DOCUMENTS... 3 1.3 PREREQUISITES...
More informationIntelliServer RAS 2000 TM PowerRack Windows NT Supplement
IntelliServer RAS 2000 TM PowerRack Windows NT Supplement 1060 Windward Parkway, Suite 100, Alpharetta, GA, 30005-3992 (USA) (800) 241-3946, Outside U.S./Canada: (770) 625-0000 FAX: (770) 625-0013 email:
More informationWIFLY SERIAL ADAPTER RN-370 & RN-374
WiFly Serial Adapter Install Guide WiFly Serial Adapter_bp-ig 8/0/09 WIFLY SERIAL ADAPTER RN-70 & RN-7 Battery Powered 80. b/g Serial Adapter Install Guide and User Manual Version.00 Sept 9 th 009 Copyright
More information1. Introduction. Be sure to read the release notes in section 10 before operating the Unit.
1. Introduction This manual describes the ways of configuring and monitoring the operation of the PROFINET IO Controller CJ1W-PNT Sample Version V0.00 V67.06 V0.00 (Internal release V6.29). Be sure to
More informationTime synchronization for APR64 / APR64M
03/21/2013 Edition Time synchronization for APR64 / APR64M dfv Technologie Z.A. Ravennes-les-Francs 2 avenue Henri Poincaré BP 80009 59588 BONDUES CEDEX FRANCE Tel : 33 (0) 3.20.69.02.85 Fax : 33 (0) 3.20.69.02.86
More informationSERVICE INSTRUCTION. Updating the firmware and software on the RCS-2
SERVICE INSTRUCTION SI-09-04.1 Replaces (SI-09-04) March 2013 SERVICE INSTRUCTION Updating the firmware and software on the RCS-2 Important Note: It is highly recommended that all parameter data be backed
More informationEXPRESS. Users Guide. Version 3.5
EXPRESS Users Guide Version 3.5 Table of Contents 1 System Overview... 3 2 System Requirements... 3 3 Contents in ECMTUNE System Box... 3 4 Installation Information... 4 5 Registration Information... 7
More informationecov-110 User s Manual (V0.9f_Eng)
ecov-110 User s Manual (V0.9f_Eng) 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ecov-110 Firmware Upgrade Appendix B. ecov-110 Serial Advanced
More informationRADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05
RADview Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L 1994 2005 RAD Data Communications Publication 07/05 Contents Chapter 1. Introduction 1.1 Overview... 1-1 General...1-1
More informationETH to 232 (A) User Manual
ETH to 232 (A) User Manual ETH to 232 (A) is data transparent transmission equipment for convert TCP or UDP socket data to RS232, small size, low power, powered by ARM processors, high speed, high Stability.
More informationASL Holdings Ltd. User Guide for the: - DELTA PLUS LAN modem. Provisional Ver1.8
Provisional Ver1.8 ASL Holdings Ltd User Guide for the: - DELTA PLUS LAN modem ASL Holdings Ltd,The Oaks, Spring Hill Office Park, Spring Hill Farm, Harborough Road, Pitsford, Northampton, NN6 9AA Tel:+44
More informationETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel
Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve
More informationUDS2100 Device Server User Guide
UDS2100 Device Server User Guide Part Number 900-448 Revision G December 2017 Intellectual Property Warranty Contacts 2017 Lantronix. All rights reserved. No part of the contents of this book may be transmitted
More informationUniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany
LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright
More informationGPS IRIG-B/NTP Time Server GPS-2-E-NTP
GPS IRIG-B/NTP Time Server GPS-2-E-NTP June 01, 2013 Contents 1 Introduction... 3 2 Hardware... 4 3 Mounting GPS antenna... 5 4 Powering up GPS-2-E-NTP... 6 5 NTP - Network Time Protocol... 7 6 GPS-2-E-NTP
More informationEmbedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.
Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4
More informationGeneral Specifications
General Specifications GS 48D50Z00-00E-N C0-950-00 Basic Communication System ProSafe-COM A major part of this functionality is mapped upon an industrial PC, thus representing ProSafe- COM. The basic hardware
More informationProjectorNetTM Adapter Quick Start Guide
ProjectorNetTM Adapter Quick Start Guide Adapter networking 1. Quick Start The ProjectorNet Adapter kit contains the following items: ProjectorNet Serial to Ethernet Adapter Cable Adapter, ProjectorNet
More informationProSoft Technology, Inc. RTU-5/03 Processor for Allen-Bradley SLC Modular Racks Inside this Manual
Revision : 1.2 Updated : 6/30/04 ProSoft Technology, Inc. RTU-5/03 Processor for Allen-Bradley SLC Modular Racks Catalog Numbers : 3250-L532M RTU-5/03 Processor with 16 K RAM This manual is provided in
More informationGW1000 User s Guide. Revision 1.04 Mar 30, 2008
GW1000 User s Guide Revision 1.04 Mar 30, 2008 Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390 Table of Contents 1.0 GW1000 General Operation & Applications... 3 2.0 Hardware Specifications...
More informationLevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver
LevelOne FBR-1416 1W, 4L 10/100 Mbps ADSL Router User s Manual Ver 1.00-0510 Table of Contents CHAPTER 1 INTRODUCTION... 1 FBR-1416 Features... 1 Package Contents... 3 Physical Details... 3 CHAPTER 2
More informationInitial Configuration for the Switch
Options for Initial Configuration, page 1 Configuring the Switch Using the Web User Interface, page 1 Configuring the Switch Using the CLI, page 4 Configuring the Switch in the ROMMON Mode, page 12 Options
More informationXPort Direct+ Integration Guide/Data Sheet
XPort Direct+ Integration Guide/Data Sheet Part Number 900-524 Revision B December 2007 Patents, Copyright and Trademark 2007, Lantronix. All rights reserved. No part of the contents of this book may be
More informationGPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with Ethernet connectivity
More informationOperation Manual EX-9133C-2-MTCP
Operation Manual EX-9133C-2-MTCP Modbus TCP to Modbus RTU/ASCII Converter Version 1.0.1 20th Oct. 2016 Page 0 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features
More informationHandsOn Technology -- HT-MC-02 MODEL: HT-MC-02
HandsOn Technology 8051 μcontroller Starter Kits FLASH μcontroller PROGRAMMER/DEVELOPMENT SYSTEM MODEL: HT-MC-02 8051 is one of the most popular 8-bit µcontroller architectures in use today, learn it the
More informationThe following are basic setup instructions for the LAN-520 AESP. Some settings may not apply to every application.
1.0 Basic LAN Device Setup The following are basic setup instructions for the LAN-520 AESP. Some settings may not apply to every application. NOTE: The LAN-520 AESP is an updated version of Keri s LAN-520X
More informationXPress DR Industrial Device Server User Guide
XPress DR Industrial Device Server User Guide Part Number 900-772-R Revision C December 2017 Intellectual Property Warranty Contacts 2017 Lantronix, Inc. All rights reserved. No part of the contents of
More informationRS-232/422/485 Over IP Adapter
RS-232/422/485 Over IP Adapter 1 port RS-232/422/485 Over IP Adapter NETRS2321E Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits
More informationTable of Contents. NBC User's Manual
User's Manual User's Manual Table of Contents 1. Connections and Power... 3 1.1. Connections and Power for WSXXXX_BR products... 3 2. Initial Configuration... 4 2.1. NBC Network Configuration... 4 2.2.
More information