Semi conductor fuses PSC 690 V DIN 43620

Size: px
Start display at page:

Download "Semi conductor fuses PSC 690 V DIN 43620"

Transcription

1 Semi conductor fuses PSC 690 V DIN 4620

2 URD 690 VAC Semiconductor Fuses PSC - URD 690 VAC Ferraz Shawmut PSC-URD 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a fast acting, engineered to provide state of the art protection for power semiconductors such as diodes, thyristors. These square body fuse-links are available in various body sizes with a broad range of ampere ratings allowing the greatest flexibility in equipment design. They have pure silver fuse elements embedded in solidified sand which provides optimized I2t and high interrupting rating. All contact surfaces are plated and all hardware non-magnetic. All fuses are standard with a low voltage blown fuse indicator. This indicator can operate a microswitch which is easily mounted directly onto the fuse in service. Beige melted Red non melted FEATURES Ultra fast acting Highly current limiting. High breaking capacities Very low I 2 t Worldwide mounting acceptance. Superior cycling ability. High widstanding in rush current and overloads APPLICATIONS Protection of rectifiers, inverters, static switch, AC & DC drives and UPS systems. INOVATIONS Double indicator(visual and mechanical). Largest range of the market Connexion improvement between trip indicator - Micro switch Cd / Pb free Low voltage indicator - V Ratings AC: up to 0 A 690 VAC -70 ka IR DC: Consult Factory Approvals AC: Tested to IEC Features/Benefits Broad range of ampere ratings in each body size for design flexibility IEC compliance for fuses for worldwide semiconductor applications 2

3 Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Voltage Size Type Rating Pre-Arcing Total I 2 t Pn: Power losses (W) Breaking In I V PV 4620 Un (A) ka 2 s ka 2 s 0,8In URD 6 8,0 URD ,5 URD ,0 URD ,5 URD 69 4,0 URD ,0 URD ,0 690 V 000 URD ,0 URD ,5 URD 8 0,5 URD 2 2 5,0 URD ,0 URD ,0 URD ,0 URD ,5 URD ,0 URD ,5 URD 69 4,0 URD 0 0 5,0 URD ,0 690 V 00 URD ,0 70 URD ,5 URD ,0 URD 2 2 4,0 URD ,0 URD ,0 URD ,0 URD ,5 URD 5 2 0,0 URD ,5 URD 0,5 URD 970 2, V 0 URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 URD 690 VAC Time/current characteristics see page 7,8,9 Cut off characteristics see page 7,8,9 Total I 2 t and total operating time see page 7,8,9 Other curves see page 0 Fuse holder derating page 0

4 URD 690 VAC Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Voltage Size Type Rating Pre-Arcing Total I 2 t Pn: Power losses (W) Breaking In I V PV 4620 Un (A) ka 2 s ka 2 s 0,8In URD 0 8 URD ,5 URD ,0 URD ,0 690 V URD ,0 URD ,0 70 URD ,0 URD ,0 URD ,0 URD ,0 URD URD URD ,5 URD ,0 URD ,0 690 V 2 URD ,5 70 URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 URD ,5 URD ,0 URD , V URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 URD ,0 4

5 Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Size Catalog Number Reference Weight Packaging Number (g) ,9 URD 000 PV 006 6,9 URD 000 PV ,9 URD 000 PV ,9 URD 000 PV 002 6,9 URD 000 PV 00 6,9 URD 000 PV 00 6,9 URD 000 PV 00 6,9 URD 000 PV 00 6,9 URD 000 PV 0 6,9 URD 000 PV 0 6,9 URD 000 PV 0 6,9 URD 000 PV 0 6,9 URD 000 PV 0 6,9 URD 000 PV 0 Neutral Extraction puller 6,9 URD 00 PV ,9 URD 00 PV ,9 URD 00 PV 002 6,9 URD 00 PV 00 6,9 URD 00 PV 00 6,9 URD 00 PV 00 6,9 URD 00 PV 00 6,9 URD 00 PV 0 6,9 URD 00 PV 0 6,9 URD 00 PV 0 6,9 URD 00 PV 0 6,9 URD 00 PV 0 6,9 URD 00 PV 0 Neutral Extraction puller 6,9 URD 0 PV 002 6,9 URD 0 PV 00 6,9 URD 0 PV 00 6,9 URD 0 PV 00 6,9 URD 0 PV 00 6,9 URD 0 PV 0 6,9 URD 0 PV 0 6,9 URD 0 PV 0 6,9 URD 0 PV 0 6,9 URD 0 PV 0 6,9 URD 0 PV 0 Neutral Extraction puller P5C R7C T9C Y4C C47C G5C L55C Q59C VC X65C B69C D7C H75C M79C Z28269J P25592A A207C C209C G204C L2047C Q205C V2055C Z2059C D20C F2065C K2069C M207C R2075C W2079C Z28269J P25592A Q2024C V20247C Z2025C D20255C H20259C M202C P20265C T20269C W2027C A20275C E20279C Z2904J P25592A P URD 690 VAC Microswitches MS 4L 2-5 B6 + PRES F2056C (6,mm clips) MS 4L 2-5 B2 + PRES G2057C (2.8 mm clips) Automatically resetable, these microswitch systems indicate fuse presence (PRES) and proper mounting In case of improper mounting or fuse melting, this is indicated (terminal -4 closed) Size A B C H L M N P R T ,8,5 52,5 5 79,5,5 4,4 49, ".59" 2.07" 0.59"." 0.5" 0.5".7".95".8" 00 29,5 47,5 59,5 5 79,, 4,4 5.6".87" 2.4" 0.59"." 0.52" 0.52".7".97".8" 0 29,5 47,5 59,5 5 29, 29, 4, ".87" 2.4" 0.59" 4.92".5".5".7" 2.60".8" Fuse holder solution, see p. Microswitches supplied seperately 5

6 URD 690 VAC Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Size Catalog Number Reference Weight Packaging Number (g) 2 6,9 URD PV 00 6,9 URD PV 00 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 Neutral Extraction puller 6,9 URD 2 PV 0 6,9 URD 2 PV 0 6,9 URD 2 PV 0 6,9 URD 2 PV 0 6,9 URD 2 PV 0 6,9 URD 2 PV 0 6,9 URD 2 PV 04 6,9 URD 2 PV 00 6,9 URD 2 PV 05 6,9 URD 2 PV 00 6,9 URD 2 PV 0 Neutral Extraction puller 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 0 6,9 URD PV 04 6,9 URD PV 00 6,9 URD PV 05 6,9 URD PV 00 6,9 URD PV 0 6,9 URD PV 00 6,9 URD PV ,9 URD PV 0 Neutral Extraction puller M2055C K2099C W20C Y2065C C2069C E207C J2075C N2079C P20C S208C A2984E P25592A L20469C N2047C S20475C X20479C Y204C B2048C D20485C F20487C G20488C H20489C J20490C N22254E P25592A F20579A G205A K2058A M20585A P20587A Q20588A R20589A S20590A T2059A V20592A W2059A E2205E P25592A P Microswitches MS 4L 2-5 B6 + PRES F2056C (6,mm clips) MS 4L 2-5 B2 + PRES G2057C (2.8 mm clips) Automatically resetable, these microswitch systems indicate fuse presence (PRES) and proper mounting In case of improper mounting or fuse melting, this is indicated (terminal -4 closed) Size A B C H L M N P R T 9,5 52,5 64, , 2, 4, " 2.07" 2.54" 0.79" 5.2".26".26".7" 2.68".57" ,85 8,85 4, " 2.6" 2.85".02" 5.9".5".5".7" 2.68".89" ,85 8,85 4, " 2.9".9".0" 5.9".5".5".7" 2.68" 2.6" Fuse holder solution, see p. Microswitches supplied seperately 6

7 Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Times/Current Characteristics t (s) C 2 Size 000 a = 0 B =,25 A2 = 0,6 B2 = 0,6 Cf = 0,8 C' t (s) C 25 2 Size 00 a = 0 B =,25 A2 = 0,6 B2 = 0,6 Cf = 0,8 C' URD 690 VAC Cut off characteristics - Peak let thru current Ic(kA) Ic = 2.5 Ip Ic = 2 Ip c(ka) Size 000 Size Ic = 2.5 Ip Ic = 2 Ip Total I 2 t and total operating 690 V Size 000 I 2t(A 2s) 0.0 ms (.00 ms) 6.0 ms (0. ms) ms (5.00 ms) 8.0 ms (.60 ms) 4.0 ms (0. ms) Ip (ka) 0 6 I 2t(A 2s) Size ms (.00 ms) 6.0 ms (0. ms) 0.0 ms (5.00 ms) 8.0 ms (.60 ms) 4.0 ms (0. ms) Ip (ka) Value between parentheses pertain to prearcing I 2 t

8 URD 690 VAC Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Times/Current Characteristics t (s) 0 2 C Size 0 a = 0 B =,25 A2 = 0,6 B2 = 0,6 Cf = 0,8 C' t (s) 0 C C' Size a = 0 B =,25 A2 = 0,6 B2 = 0,6 Cf = 0, Cut off characteristics - Peak let thru current Ic(kA) Ic = 2.5 Ip Ic = 2 Ip Size 0 c(ka) Size 2 Ic = 2.5 Ip Ic = 2 Ip 0 6 Ip (ka) 0 6 Ip (ka) Total I 2 t and total operating 690 V I 2t(A 2s) Size ms (.00 ms) 6.0 ms (0. ms) 2 I t(a ms (5.00 ms) 8.0 ms (.60 ms) 4.0 ms (0. ms) s) Size 0.0 ms (.00 ms) 6.0 ms (0. ms) 0.0 ms (5.00 ms) 8.0 ms (.60 ms) 4.0 ms (0. ms) 2 Value between parentheses pertain to prearcing I 2 t 8

9 Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Times/Current Characteristics t (s) 0 C Size 2 a = 0 B =,25 A2 = 0,6 B2 = 0,6 Cf = 0,8 C' t (s) 0 C Size a = 0 B =,25 A2 = 0,6 B2 = 0,6 Cf = 0,8 C' URD 690 VAC Cut off characteristics - Peak let thru current Ic(kA) Ic = 2.5 Ip Ic = 2 Ip Size 2 Size Ic(kA) Ic = 2.5 Ip Ic = 2 Ip Ip (ka) 0 6 Ip (ka) Total I 2 t and total operating 690 V Size ms (.00 ms) 6.0 ms (0. ms) 2 2 I t(a s) 0.0 ms (5.00 ms) 8.0 ms (.60 ms) 4.0 ms (0. ms) 0 6 Size 2 2 I t(a s) 0.0 ms (5.00 ms) ms (.00 ms) 8.0 ms (.60 ms) 6.0 ms (0. ms) Value between parentheses pertain to prearcing I 2 t

10 URD 690 VAC Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades k=f(u) Multiplier coefficient to calculate total I 2 t and total operating time K.4 P/PN Multiplier coefficient to calculate the power losses at various currents P/PN 2,0 Peak arc voltage Um(V).2,8,6, ,2, , , ,4 0, U(V) 0 0,5 0,6 0,7 0,8 0,9 I/IN U(V) Derating in fuse holders - Derating for plastic bases (see page, picture ) 2- Derating for switch-disconnectors BS and Multivert (see page, picture 2) - Derating for fused switch-disconnectors ITC (see page, picture ) 4- Derating for fused switch-disconnectors ITC with finger safe protection (see page, picture 4) Size 000 Size 00 Size 0 In 2 4 In 2 4 6,00,00,00,00 20,00,00,00,00 25,00,00,00,00 2,00,00,00,00,00,00,00,00,00,00 0,90 0,90,00,00 0,90 0,90,00 0,90 0,75 0,75,00 0,90 0,75 0,75,00 0,85 0,70 0,70 0,90 0,75 0,60 0,60 0,85 0,70 0,55 0,55 0,75 0,60 0, 0, 0,70 0,55 0,45 0,45 20,00,00,00,00 25,00,00,00,00 2,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00 0,95 0,95 0,95,00 0,90 0,90 0,90,00 0,85 0,85 0,85 0,90 0,75 0,75 0,75 0,85 0,70 0,70 0,70 0, 0,65 0,65 0,65 0,70 0,55 0,55 0,55 2,00,00,00,00 0,95 0,95 0,85 0,85 0, 0,75 0,65 Size Size 2 Size,00 0,95,00,00 0,95 0,85 0,95 0,90 0,85 0,75 0,85 0, 0,85 0,75 0,85 0, 0, 0,70 0, 0,75 0, 0,70 0, 0,70 0,75 0,70 0,75 0,70 0,75 0,65 0,75 0,70 0,70 0,65 0,70 0,65 0,65 0,60 0,65 0,60 0,90 0, 0,90 0,85 0,85 0,75 0,85 0, 0,85 0,70 0, 0,75 0,75 0,65 0,70 0,65 0,70 0,65 0,70 0,65 0,70 0,60 0,70 0,60 4 0,70 0,60 0,65 0,60 0 0,70 0,60 0,65 0,60 5 0,65 0,60 0,65 0,60 0 0,65 0,55 0,65 0,60 0,60 0,55 0,60 0,55 0,85 0,75 0, 0,75 0,85 0,75 0, 0,75 0, 0,70 0,75 0,70 4 0, 0,70 0,75 0,70 0 0,75 0,65 0,75 0,70 5 0,75 0,65 0,75 0,70 0 0,70 0,60 0,70 0,65 0,70 0,60 0,65 0,60 0 0,65 0,55 0,60 0, ,60 0, 0,60 0,55 0 0,60 0, 0,55 0, 0

11 Semiconductor Fuses German standard PSC - 690VAC URD - DIN blades Bases and fuse holders 2 Ref. R2992C Ref. V29277A Ref. J22679A Ref. E725A Type Characteristics Poles Size 000/00 Size 0 Size Size 2 Size Fuse holder Unprotected (4) R2692C T2824C A22008C E2075C X2644C screw connection 2 F28758B G28759B G796B V2595B B2454B for hole and bar terminals V29277A W29278A Y20A D2209A F24664A for 5mm Din rail 4 Z22007C H222486A H20855A R22627A K2574A Unprotected (4) F2570C N26695C E28757C F2085C W264C screw connection 2 A2722B B272B F222484B S259B D24662B for holes or bar terminals F2772A G27724A Y22006A B2207A H2572A for panels 4 S29275A R2829A X209A C24A L2568A Finger Safe Protected S282C G22677C P226724C R226726C T226728C screw connection for hole and bar terminals for DIN rail G222485A J22679A Q226725A S226727A V226729A Horizontal Class AC Ref. Y2205C S22292A -4 Ref. R20729A W220A Y2070A T278A Bases and fuse holders Switchdisconnector Fused switchdisconnector front handle N26626A N222882A Horizontal 2 B28685A Linocur AC2 C2078A Y2205A W2574A Vertical Multivert E725A T20267A Q20759A Z2206A ITC III K227824A M22886A Q2082A P208A ITCP III F209A ITC III complete () G20824A ITC III complete () K227824A ITC III complete (2) ITC III complete ITC 0 III complete ITC 0 III complete () Impossible to use microswitch (2) The axis of operation must be fragmented if the heighten (Y20770A) is not used - Internal or external control. () Necessary heighten for the use of microswitch (F2056C or G2057C) (4) Unprotected against accidental contact-not finger safe Warning : for all holders, please check maximum fuse and fuse holder operating limit. N2080A + Y20770A () Q2082A + Y20770A () P208A + Y20770A () W229674A + Y20770A ()

12 , rue Jean Novel VILLEURBANNE Cedex - FRANCE Tél. (0) Fax (0) Your contact 74 Merrimac Street Newburyport, MA 09 - USA Tél. (978) Fax (978) Edition 07/2 Ref.: G60042A Data herein contained are provided for general information purpose only and are not binding. FERRAZ SHAWMUT shall have no liability whatsoever with respect to information contained herein. Duplication, reproduction or translation of any information contained herein, in whole or in part, is strictly prohibited without prior written consent of FERRAZ SHAWMUT.

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC) Protistor size 2x72 and 2x73 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4 NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose

More information

Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 22x58 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / 0VAC (UL) Protistor size 4x gr 690VAC (IEC) / 0VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant

More information

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 4x5 gr 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

AMP-TRAP Form 101 A15QS

AMP-TRAP Form 101 A15QS AMP-TRAP Form 0 AQS SEMICONUCTOR PROTECTION FUSES AQS Amp-trap Form 0 Semiconductor Protection fuses were designed for the specific protection of diodes and other semiconductor devices rated VAC/C. The

More information

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls SIRIUS Modular System. The perfect combination Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls Everything for the control cabinet: the SIRIUS

More information

Now even more application possibilities In all facets of semiconductor protection

Now even more application possibilities In all facets of semiconductor protection Semiconductor Protection Fuses sitor ENGINEERING s Now even more application possibilities In all facets of semiconductor protection For decades now, SITOR semiconductor protection fuses have been reliably

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

DBK24. Isolated Digital Output Chassis. Overview

DBK24. Isolated Digital Output Chassis. Overview DBK24 Isolated Digital Output Chassis Overview 1 Power Requirements 2 Hardware Setup 2 Card Connection 2 Card Configuration 3 DaqBook and DaqBoard Connection 4 DaqBoard/2000 Series Board Connection 5 DaqBook

More information

CIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1

CIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1 Version 1 1. (20 Points) Given the class A network address 117.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 4,000 subnets? b. (5 Points) What is

More information

CIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1

CIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1 Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. NOTE: Router E should only be used for Internet traffic. Router A Router

More information

4. Specifications and Additional Information

4. Specifications and Additional Information 4. Specifications and Additional Information AGX52004-1.0 8B/10B Code This section provides information about the data and control codes for Arria GX devices. Code Notation The 8B/10B data and control

More information

Ferrule fuse-links 14x51 am 500 to 690VAC

Ferrule fuse-links 14x51 am 500 to 690VAC Ferrule fuse-links 4x am 0 to 690VAC Ferrule fuse-links 4x am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication

More information

Ferrule fuse-links 22x58 am 500 to 690VAC

Ferrule fuse-links 22x58 am 500 to 690VAC Ferrule fuse-links 22x8 am 0 to 690VAC Ferrule fuse-links 22x8 am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication

More information

ULTRA QUICK FUSES FOR PROTECTION OF SEMICONDUCTORS POWER NEEDS CONTROL

ULTRA QUICK FUSES FOR PROTECTION OF SEMICONDUCTORS POWER NEEDS CONTROL GENERAL INFORMATION SYSTEM D0 SYSTEM D SYSTEM C SYSTEM BS SYSTEM NV/NH ACCESSORIES CHARACTERISTICS INDEX 7 8 9 8 8 FUSES FOR PROTECTION OF SEMICONDUCTORS POWER NEEDS CONTROL Typical applications protected

More information

Fuses & Fusegear. Semiconductor fuses p. 231

Fuses & Fusegear. Semiconductor fuses p. 231 Fuses & Fusegear Semiconductor fuses p. 231 Ferrule-style Protistor fuses SC141 p. 232 to 234 Fuse holder for semiconductor ferrule fuses SC141 p. 235 to 238 DIN D & DO gr fuses p. 239 Protistor DIN 80mm

More information

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry. Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Ferrule fuse-links 10x38 gg 400 to 690VAC

Ferrule fuse-links 10x38 gg 400 to 690VAC Ferrule fuse-links x8 gg 400 to 690VAC Ferrule fuse-links x8 gg 400 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Full range protection Visual indication of

More information

RATINGS AND SPECIFICATIONS

RATINGS AND SPECIFICATIONS RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ

More information

CIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1

CIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1 Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. Router A Router B Router C Router D Network Next Hop Next Hop Next Hop Next

More information

Surge Protection Solutions

Surge Protection Solutions Surge Protection Solutions SOLUTIONS guide Surge-Trap Type 2 fail-safe Surge Protective Devices Mersen Surge Protection Solutions 1 Reducing the impact of transient damage Surge-Trap SPD offers a patented

More information

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating

More information

Siemens.com/industrial-controls

Siemens.com/industrial-controls SIRIUS Industrial Controls List 2018 Siemens.com/industrial-controls List of Contents Motor Control and Protection Soft Starters Motor Management - Simocode Monitoring Relays Commanding and Signaling Devices

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1) K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-22 /97 INSTALLATION INSTRUCTIONS Original Issue Date: 7/96 Model: ATS Market: Industrial Subject: Exercise Timer Kits PA-46650 to PA-46669, PA-46650-SD to PA-46669-SD, PA-46674 to PA-46678, PA-46674-SD

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Wiring Accessories. low voltage. Wiring Accessories

Wiring Accessories. low voltage. Wiring Accessories About CBI-electric: CBI-electric: is a South African company with more than half a century of experience in the design and manufacture of a comprehensive range of technically advanced products for electrical

More information

RSTI-EP Slice I/O. Digital Output Module

RSTI-EP Slice I/O. Digital Output Module GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

CIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1

CIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1 Version 1 Instructions Write your name on the exam paper. Write your name and version number on the top of the yellow paper. Answer Question 1 on the exam paper. Answer Questions 2-4 on the yellow paper.

More information

SIRIUS Modular System

SIRIUS Modular System SIRIUS Modular System Highly flexible system-based switching, protecting and starting siemens.com/sirius Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Contents SIRIUS

More information

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer Installation and start up instructions TAS-331DG Selectable AC transducer 4189300008G (UK) Watt or var transducer Supply and measuring voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

RCDs RCBOs MCBs Isolating Switches Switchboards

RCDs RCBOs MCBs Isolating Switches Switchboards RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DC Square-body Fuses Sizes 120 to 123 gr 750V DC

DC Square-body Fuses Sizes 120 to 123 gr 750V DC Protistor DC fuses Protistor DC fuses Sizes to 3 gr 75V DC Dimensions Size grc from to 5 A Weight 75 g Weight 65 g Main Characteristics Size Current I N ( A ) 5 63 8 5 6 5 63 8 5 6 Breaking capacity @

More information

KLIC-DI VRV PRODUCT MANUAL INTERFACE KNX DAIKIN VRV ZN1CL-KLIC-DI. Edition 4 Version 1.0

KLIC-DI VRV PRODUCT MANUAL INTERFACE KNX DAIKIN VRV ZN1CL-KLIC-DI. Edition 4 Version 1.0 PRODUCT MANUAL KLIC-DI VRV INTERFACE KNX VRV ZN1CL-KLIC-DI Edition 4 Version 1.0 Index 1. Introduction... 3 2. Installation... 5 2.1. KLIC-DI Installation... 5 2.2. Elements Description... 6 3. Configuration...

More information

The cache is 4-way set associative, with 4-byte blocks, and 16 total lines

The cache is 4-way set associative, with 4-byte blocks, and 16 total lines Sample Problem 1 Assume the following memory setup: Virtual addresses are 20 bits wide Physical addresses are 15 bits wide The page size if 1KB (2 10 bytes) The TLB is 2-way set associative, with 8 total

More information

DATA SHEET Selectable AC transducer, TAS-321 DG

DATA SHEET Selectable AC transducer, TAS-321 DG DATA SHEET Selectable AC transducer, TAS-321 DG Bi-directional current measurement on AC networks Power measurement using 2 phases on 3-phase networks Class 0.5 (IEC688) measurement Easy configuration

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module , Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Leak Sensor. TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan

Leak Sensor. TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan Enable Quick Alarm of Liquid Leak at Every Industrial Field Site, even Ultra-DI Water, with Lower Cost, Easier Setting-up and Helps for Better Reliable

More information

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

SIMATIC S plus TIA Portal

SIMATIC S plus TIA Portal Product range overview SIMATIC S7-1500 plus TIA Portal Power + Efficiency The ultimate plus in automation Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry. Your plus of

More information

FUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A

FUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A fuser_47_a_1_cat The solution for > Protection of inverters and variable speed drives FUSERBLOC 60 to 150 A Strong points > Limitation of short-circuit current Extended range fuser_49_a_1_cat FUSERBLOC

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General

More information

SUBMINIATURE MICROSWITCHES - SEALED

SUBMINIATURE MICROSWITCHES - SEALED SWITCHES.COUZET.COM MICOSWITCHES SUBMINIATUE MICOSWITCHES - SEALED VS - 88 Coil spring snap-action mechanism Wire lead or cable outputs, various terminal types with symmetric or asymmetric pinning Excellent

More information

Special Purpose Fuses

Special Purpose Fuses Cable Protectors CP & CPH Ferraz Shawmut CP Cable Protectors are special purpose limiters which are crimped or bolted to cables to clear and isolate faults quickly, increasing the reliability of service

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

ZN-DN312XE-M Quick User Guide

ZN-DN312XE-M Quick User Guide ZN-DN312XE-M Quick User Guide This manual provides instructions for quick installation and basic configuration of your IP device. Step1. Connect cables to IP device Connect required cables to the device

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Switch Mode Power Supply

Switch Mode Power Supply Switch Mode Power Supply S8JX (/0/100/10-W Models) Compact Power Supply Compliant with Global Standards Output voltages of V, 12 V, and 2 V are available for between to 10 W capacity (100 W, 10 W: 2-V

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

L50QS SERIES HIGH-SPEED ROUND BODY FUSES

L50QS SERIES HIGH-SPEED ROUND BODY FUSES 00 Vac/dc -0 A Traditional Round Body Bolted Style HF Specifications Voltage Rating Amperage Rating Interrupting Rating Time Constant Material Approvals Environmental Country of Origin AC: 00V DC: 00V

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

QF(26) - Series Miniature Circuit Breakers - High Rating ( A) 1 pole 2 pole 3 pole 3+N Features AC Circuit Breaker Hydraulic-Magnetic technology % rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N (VDE) VC 8036 compliant (SANS

More information

Excerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act

Excerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act SIRIUS ACT Core spectrum selection guide Excerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act SIRIUS ACT commanding and signaling SIRIUS ACT modern, high-performance

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

EM2020 Selectable AC transducer A (UK)

EM2020 Selectable AC transducer A (UK) Installation and start up instructions EM2020 Selectable AC transducer 4189300016A (UK) Watt or var transducer Supply and measuring voltage up to 690V Configuration via PC-interface possible FAGET 35 mm

More information

Figure 1. ELSP Current-Limiting Backup Fuse. INSTALLATION

Figure 1. ELSP Current-Limiting Backup Fuse. INSTALLATION Fusing Equipment Current-Limiting Backup Fuse Electrical Apparatus - GENERAL The Cooper Power Systems Current-limiting Backup Fuse is used in series with low current primary protection devices such as

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 57 Individual mounting Series inline 35 To accumulator Sealed solenoid enclosure 100 200 Ext. pilot port Pilot valve Function plate From accumulator

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information