Setup and Configuration of Leased Line Modem with NxLink (Vector)

Size: px
Start display at page:

Download "Setup and Configuration of Leased Line Modem with NxLink (Vector)"

Transcription

1 Setup and Configuration of Leased Line Modem with NxLink (Vector) IS08004 Issue March 2008 Nautel Limited Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T nautel (628835) or F info@nautel.com U.S. customers please contact: Nautel Inc. 201 Target Industrial Circle, Bangor ME T nautel (628835) or F info@nautel.com support@nautel.com Copyright 2008 NAUTEL. All rights reserved.

2

3 IS08004 Setup and Configuration of Leased Line Modem with NxLink (Vector) INFORMATION SHEET 1 INTRODUCTION This document provides setup and configuration information for leased line modems. The leased line modems, with a Nautel NxLink Ethernet interface module will provide constant communication with your Vector NDB from a remote location, which allows you to remotely control the NDB as well as receive and monitor important data from the NDB. Figure 1 shows the connection diagram for a leased line setup. The modem on the remote (NDB) side is located inside the front door of the transmitter and is connected to remote interface PWB A3 using RS-232 male-to-female cable. The modem on the host side is connected to the NxLink using RS-232 male-to-female cable. The NxLink is then connected to a host PC, using a cross-over Ethernet cable or through a hub. 2 SETUP AND CONFIGURATION 2.1 Modems Configure each modem for leased line operation. One modem will be configured as originate or the dialing out modem. The other modem will be configured as the answer or receiving modem. It makes no difference which side is configured as originate or receive. This procedure configures the host modem as originate and the remote modem as answer. (a) On the NDB side, disconnect the cable between the modem and remote interface PWB A3. Connect an RS-232 female-to-male modem cable between your PC (or laptop) and the COM port of the modem. PC Host NxLink Multitech Modem Leased Line Multitech Modem NDB Figure 1: Serial Bridge Profile Setup & Configuration Leased Line Modem with NxLink Page 1 IS08004 Issue 1.0

4 Figure 2: COM Properties (b) Open HyperTerminal (see Figure 2) or similar program and set up the serial settings as follows: Baud Rate: Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None (c) When the connection is established, type the following on the screen within ten seconds: +++AT&F (press Enter) (d) To see typed text on the screen, go to File, Properties, Setting, ASCII Setup (see Figure 3). Check the Echo typed characters locally checkbox. (e) Set the initialization string for each modem by entering the following: Originate modem (host side modem): ATS0=1S2=128S9=0%C0\Q0\N3$MB 33600$SB19200$EB0&E12V0X7\V0 E0+DCS=0,0 (press Enter) AT&L1&D0%DC1&W0 (press Enter) Answer modem (remote side modem): ATS0=1S2=128S9=0%C0\Q0\N3$MB 33600$SB19200$EB0&E12V0X7\V0 E0+DCS=0,0 (press Enter) AT&L2&D0%DC1&W0 (press Enter) NOTE Make sure to enter all lines exactly as shown. Each time you press Enter the cursor should return to the beginning of the line and display a 0. The 0 indicates that the line of string was successfully entered. You may want to type the string in a word processing program, then use copy and paste. If you make a mistake simply re-type +++AT&F and press Enter. You may need to reboot the modem. Page 2 Issue 1.0 Setup & Configuration Leased Modem with NxLink IS08004

5 Figure 3: ASCII Setup (f) After each modem has been set up, reconnect them to their device using the RS-232 cables provided. Connect the originate modem to the NxLink and the answer modem to the NDB. Connect the modems to the leased line phone jack. (g) The modems should automatically dial up and connect to each other. It will take about 50 s for the modems to connect. 2.2 NxLink The NxLink is preconfigured for DHCP. This means that it will automatically be given an IP address. If connected to a DHCP configured network, you will need to set the baud rate to match the modem and you should give the NxLink a fixed IP address. This can be done using a NetBurner discovery tool. You may leave the NxLink and the host PC with the DHCP setting, but you may be required to search for it each time the NxLink is rebooted. (a) Connect your laptop to the NxLink s Ethernet port using a cross-over Ethernet cable or through a hub. Apply power to the NxLink using the supplied adapter. Configure the NxLink using the discovery tool [see step (b)] or using HyperTerminal [see step (c)]. (b) Navigate to the discovery tool at the following web page (see Figure 4): downloads.html (NetBurner IPSetup Tool). Open the application. It should automatically search and find the NxLink. If not, click Search Again. Once found, click on the unit in the Select a Unit screen. The NDK Settings will now display the IP address, etc. of the NxLink. The IP address at this point should be Change the NDK Settings as follows and press Set: IP: Network Mask: GateWay: Setup & Configuration Leased Line Modem with NxLink Page 3 IS08004 Issue 1.0

6 Figure 4: NetBurner IPSetup V2.0 Change the baud rate to The IP address is not critical and can be changed as needed. Pressing Search Again should find the NxLink with the new IP address. (c) Configure the NxLink using HyperTerminal. Connect an RS-232 female-to-female null modem cable from your computer to Port 0 of the NxLink. Open up HyperTerminal and set up the COM port as follows: Baud Rate: Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None (d) Connect power to the NxLink. A message should appear Waiting 10sec to start A to abort. Type A to display the following message: Netburner SB72EX Monitor V1.0 Jul :06:03 HELP for help nb> (e) Type Setup and press enter. The following menu will appear: MAC address=00-03-f )IP Address = )IP Mask = )IP Gateway = )TFTP Server= )TFTP File = 6.)Baudrate = )Wait =10 8.)Boot to Application 9.)Exceptions CauseReboot A.)DNS Server = B.)Boot Port =0 C.)Switch to Quiet Boot 1-B to change, S to save, X to exit (f) Item 6 sets the NxLink s baud rate. Type 6 and press enter. Now type and then press enter. The same menu should re-appear with the new baud rate. Perform the same steps to change the IP address 1 and the IP Gateway 3. Finally Type S and press Enter to save the change. The following message will appear: Page 4 Issue 1.0 Setup & Configuration Leased Modem with NxLink IS08004

7 Programming Flash from :FFC04000 To:FFC04094 Copying image from: FFC0039C, FFC0043E to:023ffc40 Image copied to start 'A' to abort Configured IP = Configured Mask = MAC Address= 00:03:f4:02:58:69 (g) Disconnect the cable from Port 0 of the NxLink and reboot the NxLink by disconnecting and reconnecting its power. NOTE Skip step (h) if the NxLink and host PC are set up for DHCP. (h) On your PC navigate to the Internet Protocol (TCP/IP) Properties page (see Figure 5): in Windows XP, click on Start, Control Panel, and Network Connections. Right click on the local area connection and select Properties in the pop-up menu. On the Local Area Connections Properties page scroll down and click on Internet Protocol (TCP/IP) then select Properties. Select Use the following IP address and configure as follows. IP address: Subnet mask: Default gateway: The IP address is not critical, but make sure the Default gateway is the same for both the NxLink and the PC. Figure 5: Internet Protocol (TCP/IP) Properties Setup & Configuration Leased Line Modem with NxLink Page 5 IS08004 Issue 1.0

8 2.3 Completion of Setup Setup for the modems and NxLink is complete. Navigate to your browser and enter the IP address of the NxLink (e.g., ). The NxLink Remote Control page will open (see Figure 6). Figure 6: NxLink Remote Control page Page 6 Issue 1.0 Setup & Configuration Leased Line Modem with NxLink IS08004

9 3 TROUBLESHOOTING If the leased line modems are not communicating properly, check the following: 3.1 Connections Check for loose cables and connections. Ensure that modems, NDB and NxLink have power. 3.2 Signal Verify that the NDB side modem s TR LED is on. If the LED is not on, check the connection. The NxLink side modem s TR LED should not be on. 3.3 Communication Listen to the modems and verify that they are trying to establish a connection. Only the originate modem will try to dial out. If there is no attempt to connect after a few minutes, it is possible that the Initialization string may have been entered incorrectly. You will see the CD LEDs turn on once the modems have established a connection. The TD and RD LEDs will flash when the modems are transmitting data to each other. 3.4 Serial Settings If the CD LED is on and TD and RD LEDs are flashing but the NxLink web page indicates it is not connected to the device, try rebooting all devices starting with the host modem and finishing with the NxLink. Also, verify that all serial settings are correct. They should all be set as follows: Baud Rate: Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None Setup & Configuration Leased Line Modem with NxLink Page 7 IS08004 Issue 1.0

Information Sheet IS VS Series FM Transmitter - Software Upgrade. (from VS SW 2.x to VS SW 4.x) Issue December 2013

Information Sheet IS VS Series FM Transmitter - Software Upgrade. (from VS SW 2.x to VS SW 4.x) Issue December 2013 Information Sheet IS13009 VS Series FM Transmitter - Software Upgrade (from VS SW 2.x to VS SW 4.x) Issue 1.1...06 December 2013 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4

More information

Exporter E2X Configuration

Exporter E2X Configuration Exporter E2X Configuration IS06009 Issue 1.0... 17 August 2006 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or +1.902.823.2233 F.+1.902.823.3183 info@nautel.com

More information

VR-Link RCMS Interface Unit

VR-Link RCMS Interface Unit VR-Link RCMS Interface Unit Technical Instruction Manual Issue 0.6...19 July 2010 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T. 877 6 nautel (628835) or +1.902.823.2233

More information

V Series Power Module Alarm De-Sensitized Firmware Upgrade

V Series Power Module Alarm De-Sensitized Firmware Upgrade V Series Power Module Alarm De-Sensitized Firmware Upgrade IS06019 Issue 1.1... 18 January 2007 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.+1.902.823.2233 F.+1.902.823.3183

More information

Exporter Plus - Reliable HD Protocol Setup

Exporter Plus - Reliable HD Protocol Setup Exporter Plus - Reliable HD Protocol Setup IS09003 Issue 0.2... 19 March 2009 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or +1.902.823.2233 F.+1.902.823.3183

More information

Exporter Plus - Reliable HD Protocol Setup

Exporter Plus - Reliable HD Protocol Setup Exporter Plus - Reliable HD Protocol Setup IS10010 Issue 1.0... 16 August 2010 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or +1.902.823.2233 F.+1.902.823.3183

More information

Information Sheet IS13004

Information Sheet IS13004 Information Sheet IS13004 NV and NX Series - Burning Compact Flash Card Issue 1.1... 03 May 2013 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or +1.902.823.2233

More information

Information Sheet IS13004A

Information Sheet IS13004A Information Sheet IS13004A NV and NX Series - Burning Compact Flash Card Issue 1.3... 20 November 2015 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835)

More information

Information Sheet IS15006

Information Sheet IS15006 Information Sheet IS15006 GV Series - Burning Compact Flash Card Issue 1.0... 9 November 2015 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or +1.902.823.2233

More information

SB72EX User's Manual

SB72EX User's Manual etburner SB72EX User's Manual Revision: 1.8 October 8, 2009 SB72EX User's Manual, 350030-001 Table of Contents Table of Contents...2 Overview of the SB72EX Dual-port Serial to Ethernet Device... 3 Overview

More information

Vector Series - NAPI80 Site Interface PWB Installation Procedure

Vector Series - NAPI80 Site Interface PWB Installation Procedure Vector Series - NAPI80 Site Interface PWB Installation Procedure IS09006A Issue 0.2...08 July 2009 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or

More information

V1.2.0 Importer Software Upgrade Procedure

V1.2.0 Importer Software Upgrade Procedure V1.2.0 Importer Software Upgrade Procedure IS05013 Original Issue 1.0 25 November 2005 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.+1.902.823.2233 F.+1.902.823.3183 info@nautel.com

More information

COMMUNICATION WITH OTHER SERIAL DEVICES

COMMUNICATION WITH OTHER SERIAL DEVICES Application Bulletin: #169 Date: November 2009 BLACKBELT COMMUNICATIONS INTERFACE The setup and operation of the Sentinel BLACKBELT communication options are explained in Error! Reference source not found.,

More information

May 2016 Version 1.2.7

May 2016 Version 1.2.7 May 2016 Version 1.2.7 2 Introduction Copyright Copyright 2016 4RF Limited. All rights reserved. This document is protected by copyright belonging to 4RF Limited and may not be reproduced or republished

More information

Serial-to-Ethernet Tunnel Application Note

Serial-to-Ethernet Tunnel Application Note Serial-to-Ethernet Tunnel Application Note Introduction This application note applies to the platforms listed below. SBL2e based Serial To Ethernet devices can also do serial tunneling but the default

More information

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07 ELK-IP232 Ethernet to Serial Bridge INSTALLATION AND CONFIGURATION MANUAL http://www.ness.com.au email: support@ness.com.au 1/07 Table of Contents Features and Specifications...3 Basics of Networking...4

More information

APPLICATION NOTE. Configuring LON Communications over IP using the i.lon 600

APPLICATION NOTE. Configuring LON Communications over IP using the i.lon 600 APPLICATION NOTE Configuring LON Communications over IP using the i.lon 600 Configuring IP Network Devices Part II: Transmission of LON over IP Using the i.lon 600 Network Devices: i.lon SmartServer (System

More information

How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers

How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers Bruce Chen, Project Supervisor, Moxa Technical Support Dept. Moxa offers the boot loader utility for firmware upgrade or

More information

SMC Barricade Routers

SMC Barricade Routers SMC Barricade Routers User Guide SMC7004BR V1.0 Congratulations on your purchase of the SMC Barricade. The SMC Barricade is a Broadband Router designed to share Internet Access, provide security, and to

More information

Site Ethernet Interface Installation Manual

Site Ethernet Interface Installation Manual Site Ethernet Interface Installation Manual PK XXXX 10/03 1 of 22 Second Edition A publication of Kaba Ilco, Inc. 7301 Decarie Blvd. Montreal, Quebec Canada H4P 2G7 Printed in Canada, 2002 Copyright by

More information

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ]

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ] How to XTA Electronics Ltd. The Design House Vale Business Park Worcester Road Stourport-on-Severn Worcs. DY13 9BZ. England Tel: 01299 879977 (Intl. +44 1299 879977) Fax: 01299 879969 (Intl. +44 1299 879969)

More information

installation manual SALES AND ADMINISTRATION (toll free)

installation manual SALES AND ADMINISTRATION (toll free) installation manual SALES AND ADMINISTRATION 800.637.2645 (toll free) 217.442.0611 sales@timeomatic.com TECHNICAL SUPPORT 866.637.2645 (toll free) service@timeomatic.com www.watchfiresigns.com Quick Start-Up

More information

SOHO 6 Wireless Installation Procedure Windows XP with Internet Explorer 5.x & 6.0

SOHO 6 Wireless Installation Procedure Windows XP with Internet Explorer 5.x & 6.0 SOHO 6 Wireless Installation Procedure Windows XP with Internet Explorer 5.x & 6.0 Before you Begin Before you install the SOHO 6 Wireless, you must have: A computer with a 10/100BaseT Ethernet card installed

More information

Installation and User Guide

Installation and User Guide Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol

More information

EEG ComCC 1250m Modem Data Multiplexer

EEG ComCC 1250m Modem Data Multiplexer EEG ComCC 1250m Modem Data Multiplexer Product Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York 11735 TEL: (516) 293-7472 FAX: (516) 293-7417 Copyright EEG Enterprises, Inc. 2010 All

More information

ZyWALL 70. Internet Security Appliance. Quick Start Guide Version 3.62 December 2003

ZyWALL 70. Internet Security Appliance. Quick Start Guide Version 3.62 December 2003 ZyWALL 70 Internet Security Appliance Quick Start Guide Version 3.62 December 2003 Introducing the ZyWALL The ZyWALL 70 is the ideal secure gateway for all data passing between the Internet and the LAN.

More information

Part # Quick-Start Guide. SpeedStream Residential Gateway 5450 Four-Port Router

Part # Quick-Start Guide. SpeedStream Residential Gateway 5450 Four-Port Router Part # 007-6560-001 Quick-Start Guide SpeedStream Residential Gateway 5450 Four-Port Router Before you begin, Verify that the following items came with your DSL kit: 1 SpeedStream Device 2 Documentation

More information

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual CAS-2700-42 IKS to Modbus RTU Gateway CAS 2700-42 IKS Gateway (Modbus RTU/TCP and HTML) Manual CAS 2700-42 IKS Gateway Manual Page 1 of 34 BLANK PAGE CAS 2700-42 IKS Gateway Manual Page 2 of 34 Contents

More information

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide 48-Port 10/100/1000Base-T with 4 Shared SFP Managed Gigabit Switch WGSW-48000 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to

More information

Chapter 1 Getting Started with Switch Management

Chapter 1 Getting Started with Switch Management Chapter 1 Getting Started with Switch Management This section provides an overview of switch management, including the methods you can choose to start managing your NETGEAR GS700TS Gigabit Stackable Smart

More information

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...

More information

TITLE: Device Server Configuration/Installation Manual

TITLE: Device Server Configuration/Installation Manual TITLE: Device Server Configuration/Installation Manual TechNote: 000269 Symptom: Error Message: Solution: 1: Device Server Introduction A: Overview B: Redirector Software C: Typical Installation 2: Hardware

More information

GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet

GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet GE Security GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet Package Contents Thank you for purchasing the GE Security 7/8-Port Fast Ethernet + 2/3-Port Gigabit TP/SFP Combo Managed Switch. The

More information

International Headquarters. European Headquarters

International Headquarters. European Headquarters VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_1116 Revision: March 2016 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International Headquarters

More information

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax: Product: DFL-500 Internet Firewall Index Setup Introduction...2 Set Up Using Web Configurator...3 Setting Up Internal IP Address using CLI...4 Setting UP External IP Address Manually Using CLI...4 How

More information

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422

More information

Table of Contents. NBC User's Manual

Table of Contents. NBC User's Manual User's Manual User's Manual Table of Contents 1. Connections and Power... 3 1.1. Connections and Power for WSXXXX_BR products... 3 2. Initial Configuration... 4 2.1. NBC Network Configuration... 4 2.2.

More information

International Headquarters. European Headquarters

International Headquarters. European Headquarters VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_0613 Revision: 2.0 -- February 2013 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International

More information

RoadRunner 24AP(i+) Recovering Tool Instructions

RoadRunner 24AP(i+) Recovering Tool Instructions RoadRunner 24AP(i+) Recovering Tool Instructions Ver. 1.0 Follow these instructions if your modem do not boot. If you have questions or problems using this modem build in recovering tool, please contact

More information

ZyWALL 10W. Internet Security Gateway. Quick Start Guide Version 3.62 December 2003

ZyWALL 10W. Internet Security Gateway. Quick Start Guide Version 3.62 December 2003 Internet Security Gateway Quick Start Guide Version 3.62 December 2003 Introducing the ZyWALL The is the ideal secure gateway for all data passing between the Internet and the LAN. By integrating NAT,

More information

Upgrading the Cisco D9887B HDTV Modular Receiver Technical Reference

Upgrading the Cisco D9887B HDTV Modular Receiver Technical Reference Upgrading the Cisco D9887B HDTV Modular Receiver Technical Reference Overview Introduction This document describes the procedure required to upgrade the Cisco D9887B HDTV Modular Receiver. Audience This

More information

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide 28-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-28040 / WGSW-28040P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5

More information

ETOR-4. Ethernet/Serial Gateway USER MANUAL

ETOR-4. Ethernet/Serial Gateway USER MANUAL ETOR-4 Ethernet/Serial Gateway USER MANUAL 1 TABLE OF CONTENTS SECTION 1 GENERAL INFORMATION...6 SECTION 2 INSTALLATION...9 2.1 Definitions on ETOR... 9 2.2 Configuring ETOR...10 2.3 Required Installations

More information

NordField Electronics

NordField Electronics NordField Electronics XS1000 TCP/IP to RS232/422/485 Device Server Overview and quick info sheet 3.0. Hardware Installation & Initial Setup 3.1 RS-232 Configuration:(DB9 Male) (DB9Male) Signal I/O PIN2

More information

Ethernet Serial Server

Ethernet Serial Server Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4

More information

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT 8-Port 10/100Mbps + 2G TP/SFP Combo Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements...

More information

WiBox 2100 Quick Start Guide

WiBox 2100 Quick Start Guide WIBOX 2100 Quick Start Guide 2004 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-367 07/04 WIBOX 2100 QUICK START CONTENTS What s in the Box..........................................................2

More information

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL ETOR-4 Ethernet/Serial Gateway USER MANUAL 1 TABLE OF CONTENTS SECTION 1 GENERAL INFORMATION...6 SECTION 2 INSTALLATION...9 2.1 Definitions on ETOR... 9 2.2 Configuring ETOR...10 2.3 Required Installations

More information

How to download EDS Data Using a Cable on Windows for PW305A/B

How to download EDS Data Using a Cable on Windows for PW305A/B How to download EDS Data Using a Cable on Windows for PW305A/B Please note that a download using a cable can take up to 30 min and a power source for the laptop should be available to back up the laptop

More information

Broadband Router DC-202. User's Guide

Broadband Router DC-202. User's Guide Broadband Router DC-202 User's Guide Table of Contents CHAPTER 1 INTRODUCTION... 1 Broadband Router Features... 1 Package Contents... 3 Physical Details...3 CHAPTER 2 INSTALLATION... 5 Requirements...

More information

VisionTouch 5 Software

VisionTouch 5 Software User Manual VisionTouch 5 Software Greengate Contents Contents Description General Information.... 3 Hardware and Software Requirements.... 3 Hardware Requirements.... 3 Software Requirements... 3 VisionTouch

More information

FSA-CU Configuration Utility Programming Guide

FSA-CU Configuration Utility Programming Guide FSA-CU Configuration Utility Programming Guide Revision 3 October 2013 Introduction The following guide will show you the basics of the FSA-CU configuration utility program. The CU can be used with the

More information

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any This product can be set up using any current web browser, i.e., Internet Explorer 6x or Netscape Navigator 7x. DSL-G624T Wireless ADSL Router Before You Begin 1. If you purchased this Router to share your

More information

ecov-110 User s Manual (V0.9f_Eng)

ecov-110 User s Manual (V0.9f_Eng) ecov-110 User s Manual (V0.9f_Eng) 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ecov-110 Firmware Upgrade Appendix B. ecov-110 Serial Advanced

More information

NetGator Quick Start Guide

NetGator Quick Start Guide NetGator Quick Start Guide NetGator is a compact sized standalone system integrating all the real time MPEG and JPEG compression engine, as well as a number of network protocols, including IP multicasting.

More information

IPR10. Quick Start Guide and Application Notes

IPR10. Quick Start Guide and Application Notes IPR10 Quick Start Guide and Application Notes Model: IPR10 Quick Start and Application Notes The IPR10 is an access router with asynchronous serial RS-232 interface for use with dial-up modems, leased

More information

DI-808HV 8-Port Broadband VPN Router

DI-808HV 8-Port Broadband VPN Router This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DI-808HV 8-Port Broadband VPN Router 1. Thank you for purchasing this Router to share your

More information

Manual Documentation Number: ES1A-2907m pn6909-rev003 B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box Ottawa IL Ph

Manual Documentation Number: ES1A-2907m pn6909-rev003 B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box Ottawa IL Ph Model: ES1A Mini Ethernet to RS-232 Converter Manual Documentation Number: ES1A-2907m pn6909-rev003 Manual Documentation Number: ES1A-2907m pn6909-rev003 International Headquarters B&B Electronics Mfg.

More information

Upgrade Instructions. M5PXNplus and M2000PXNplus. Introduction. Removing the CPU board. Micro/PX-2000 and Micro/PXN Micro/5-PX and Micro/5-PXN

Upgrade Instructions. M5PXNplus and M2000PXNplus. Introduction. Removing the CPU board. Micro/PX-2000 and Micro/PXN Micro/5-PX and Micro/5-PXN M5PXNplus and M2000PXNplus 460631001B June 2009 Copyright 2009, GE Security Inc. Introduction The PXNplus CPU board contains an advanced processor which is more powerful and faster than its predecessors.

More information

Using Cisco IOS Software

Using Cisco IOS Software APPENDIX A This appendix describes the basics about using the Cisco IOS software that is installed on every Cisco ubr905 and Cisco ubr925 cable access routers: Accessing the Command-Line Interface, page

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

The following simple procedures should be performed prior to testing the 289H M relay card:

The following simple procedures should be performed prior to testing the 289H M relay card: 289H M LSS Installation & Operations Manual Start Up & Test Procedures Chapter 5 INTRODUCTION The information in this section of the manual provides the step by step procedures for conducting any testing

More information

Using the Lantronix WiBox with the CR800 or CR1000

Using the Lantronix WiBox with the CR800 or CR1000 5 Gould Road, PO Box 2155 New London, NH 03257 USA Voice: (603) 526-9800 info@canarysystems.com www.canarysystems.com Using the Lantronix WiBox with the CR800 or CR1000 Application Note #23 Revision 02/03/2017

More information

UDS1100 User Guide Part Number Revision D August 2008

UDS1100 User Guide Part Number Revision D August 2008 UDS1100 User Guide Part Number 900-417 Revision D August 2008 Copyright & Trademark Contacts 2006, 2007, 2008 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or

More information

GEM80 & ewon Setup Quick Guide

GEM80 & ewon Setup Quick Guide Introduction to the ewon The ewon is an intelligent, programmable Ethernet Gateway, which can be used to bridge GEM 80 PLCs onto an Ethernet network, via the PLC serial port (Port3). This provides network-based

More information

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router Part # 007-0-00 Quick-Start Guide SpeedStream 00 Modem PPPoE Modem Router Before you begin, Verify that the following items came with your DSL kit: Step > Install Line Filters 7 SpeedStream Device Documentation

More information

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual Communication Instruction Manual IM3523 IM3533 IM3533-01 IM3536 LCR METER IM3570 IM7580 IMPEDANCE ANALYZER IM3590 CHEMICAL IMPEDANCE ANALYZER November 2014 Revised edition 6 IM3570A983-06 14-11H i Contents

More information

Thermal Printer Configuration (EPSON)

Thermal Printer Configuration (EPSON) Thermal Printer Configuration (EPSON) STEP A : IDENTIFY THE THERMAL PRINTER MODEL Check for your EPSON printer model by finding the label on the printer. Figure 1.1 For the example above (Figure 1.1),

More information

SVMi-8E/SVMi-16E Installation

SVMi-8E/SVMi-16E Installation SVMi-8E/SVMi-16E Installation Table of Contents 1 Installing the SVMi-8E/SVMi-16E in the Phone System 3 Installing the SVMi-8E in an idcs 100 3 General 3 System Resources 3 idcs 100 Hardware Compatibility

More information

QUICK START GUIDE MODEL 195Ep

QUICK START GUIDE MODEL 195Ep QUICK START GUIDE MODEL 195Ep Before You Begin The ESTeem Model 195Ep wireless Ethernet radio modem is compatible with many different applications. The most common application is to bridge two or more

More information

Application Note Redundancy Configuration FG-110 FF

Application Note Redundancy Configuration FG-110 FF Application Note Redundancy FG-110 FF 1 Commissioning the Hardware... 2 1.1 Hardware Installation... 2 1.2 Adding a Second Linking Device... 3 2 Commissioning the Software... 3 2.1 Network... 3 2.2 of

More information

WiSpan Quick Start Guide

WiSpan Quick Start Guide Quick Start Guide 2008 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-462 Rev. B 06/08 QUICK START CONTENTS What s In the Box..........................................................2

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

BEFCMU10 EtherFast Cable Modem with USB and Ethernet Connection. 12V-DC (0.6A min) power is connected. OFF

BEFCMU10 EtherFast Cable Modem with USB and Ethernet Connection. 12V-DC (0.6A min) power is connected. OFF LED Table LED Color Mode Function Power Green ON 12V-DC (0.6A min) power is connected. OFF Power is not connected, power supply is incorrect or bad, or BEFCMU10 is bad. Activity Green ON Connection to

More information

Using the Lantronix SGX 5150 Serial Device Server

Using the Lantronix SGX 5150 Serial Device Server 5 Gould Road, PO Box 2155 New London, NH 03257 USA Voice: (603) 526-9800 info@canarysystems.com www.canarysystems.com Using the Lantronix SGX 5150 Serial Device Server Application Note #28 - Revision 12/2018

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

High Speed Internet set up guide. Read me first

High Speed Internet set up guide. Read me first High Speed Internet set up guide Read me first Welcome Thank you for choosing TELUS. The 10 simple steps in this guide will help you set up your modem and quickly connect to the Internet. If you have questions

More information

AP-ENBD User Manual V0.2

AP-ENBD User Manual V0.2 AP-ENBD User Manual V0.2 2015/12 Catolog Catolog... 2 1 Introduction... 1 1.1 Communication Structure... 1 1.2 Internal Principle... 2 2 Installation... 2 2.1 Connect to the Same Router (or Switch )...

More information

Quick Start Guide Bluetooth Serial Adapter

Quick Start Guide Bluetooth Serial Adapter Quick Start Guide Bluetooth Serial Adapter GBC232A PART NO. Q1375 www.iogear.com o o Package Contents 1 1 x GBC232A Bluetooth Serial Adapter 1 x RS232 Extension Cable 1 x Null Modem Adapter (Female) 1

More information

LevelOne. User's Guide. Broadband Router FBR-1402TX FBR-1403TX

LevelOne. User's Guide. Broadband Router FBR-1402TX FBR-1403TX LevelOne Broadband Router FBR-1402TX FBR-1403TX User's Guide Table of Contents CHAPTER 1 INTRODUCTION... 1 LevelOne Broadband Router Features... 1 Package Contents... 3 Physical Details...4 CHAPTER 2 INSTALLATION...

More information

Configuring the Switch with the CLI-Based Setup Program

Configuring the Switch with the CLI-Based Setup Program Configuring the Switch with the CLI-Based Setup Program Accessing the CLI Through Express Setup, page 1 Accessing the CLI Through the Console Port, page 1 Entering the Initial Configuration Information,

More information

Gigaset Router / en / A31008-E105-B / cover_front_router.fm / s Be inspired

Gigaset Router / en / A31008-E105-B / cover_front_router.fm / s Be inspired s Be inspired Table of Contents Table of Contents Safety precautions........................... 3 The Gigaset Router........................... 3 Features and Benefits..................................................

More information

Table of Contents. Keyspan:USB Server - User Manual

Table of Contents. Keyspan:USB Server - User Manual Table of Contents 1 Introduction Compatible USB Devices Connectivity to USB Devices Connectivity to Network Requirements What's Inside The Package 2 Installation Instructions Installing the USB Server

More information

Step-by-Step Setup Guide Wireless File Transmitter

Step-by-Step Setup Guide Wireless File Transmitter EOS Step-by-Step Setup Guide Wireless File Transmitter Server Mode Infrastructure & Ad Hoc Networks Windows XP / Windows 7 2012 Canon U.S.A., Inc. All Rights Reserved. Reproduction in whole or in part

More information

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK 1 USING THE XPERT2 / 9210B ON A TCP/IP NETWORK Prepared by: R&D January, 2009 Updated September 26, 2013 Sutron Corporation 22400 Davis Drive Sterling, Virginia 20164 TEL: (703) 406-2800 FAX: (703) 406-2801

More information

Wireless serial cable using WiFi devices servers

Wireless serial cable using WiFi devices servers APPLICATION NOTE Ref APNUS001 rev. A-0, January 2, 2005 Wireless serial cable using WiFi devices servers This application note describes how to replace a RS232/422/485 cable between 2 serial devices by

More information

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring

More information

Ethernet-232 User s Manual

Ethernet-232 User s Manual Ethernet-232 User s Manual Design Gateway Co., Ltd. Rev 1.0 (PD0503-6-00-01E) *** Please read this manual carefully before using Ethernet-232 *** Revision History Revision Date Detail of change 1.0 28

More information

Troubleshooting Can not access the router on

Troubleshooting Can not access the router on Troubleshooting Can not access the router on 192.168.0.1 Please note that when accessing the router s Web interface via http://192.168.0.1 you are not accessing some web site on the Internet. The router

More information

24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch

24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch 24-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-24040 / WGSW-24040R SGSW-24040 / SGSW-24040R SGSW-24040P / SGSW-24040P4 SGSW-24240 / SGSW-24240R SGSW-24040HP Quick Installation Guide

More information

Configuring the Switch with the CLI-Based Setup Program

Configuring the Switch with the CLI-Based Setup Program Configuring the Switch with the CLI-Based Setup Program This appendix contains these topics: Accessing the CLI Through Express Setup, page 1 Accessing the CLI Through the Console Port, page 1 Entering

More information

ECOV-110 User s Manual

ECOV-110 User s Manual ECOV-110 User s Manual 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ECOV-110 Firmware upgrade ECOV-110 1. ECOV-110 Product Introduction: 1.1.

More information

APPLICATION NOTE. Configuring Audio over IP- Instreamer/Extreamer

APPLICATION NOTE. Configuring Audio over IP- Instreamer/Extreamer APPLICATION NOTE Configuring Audio over IP- Instreamer/Extreamer Configuring IP Based Network Devices: Instreamer/Extreamer (Audio) & i.lon 600 (LON) Part 1: Transmission of Audio over IP Network Devices:

More information

Bluetooth Application Note

Bluetooth Application Note Bluetooth Application Note FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits

More information

Initial Configuration for the Switch

Initial Configuration for the Switch Options for Initial Configuration, page 1 Configuring the Switch Using the Web User Interface, page 1 Configuring the Switch Using the CLI, page 4 Configuring the Switch in the ROMMON Mode, page 12 Options

More information

Monitor and Manage your Power System with Ease.

Monitor and Manage your Power System with Ease. Model 2000 Recorder Functional IRIG-B Functional Records Stored Test Mode Alarm Model 2000 Recorder Functional IRIG-B Functional Records Stored Test Mode Alarm People with Passion Accessing Multiple Remote

More information

Service Bulletin Rev Firmware Upgrade for ACRC100 Series

Service Bulletin Rev Firmware Upgrade for ACRC100 Series Rev. 3.1.0 Firmware Upgrade for ACRC100 Series Objective This Service Bulletin defines the procedure for upgrading the firmware for the InRow ACRC to version AOS 3.1.3 and APP 3.1.0. This upgrade is mandatory

More information

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual HOME AUTOMATION, INC. Model 93A00-1 Serial Server User s Manual Document Number 93I00-1 Rev. A December, 2009 Introduction The 93A00-1 is a RS232/RS485 to TCP/IP converter integrated with a robust system

More information

IPS-800/1600-D20 Series

IPS-800/1600-D20 Series WTI Part No.: 13614 Rev. A IPS-800/1600-D20 Series Models: IPS-800-D20 IPS-800E-D20 IPS-1600-D20 IPS-1600E-D20 Internet Power Switches User s Guide SECURE RACKING Warnings and Cautions: INSTALLATION INSTRUCTIONS

More information

Bridge Cable User s Guide

Bridge Cable User s Guide Bridge Cable User s Guide Table of Contents Overview -------------------------------------------------------------------- 2 Driver Installation --------------------------------------------------------

More information