Sun Ethernet Fabric Operating System. RIP Administration Guide
|
|
- Gabriel Norman
- 5 years ago
- Views:
Transcription
1 Sun Ethernet Fabric Operating System RIP Administration Guide Part No: E July 2015
2
3 Part No: E Copyright 2010, 2015, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited. The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing. If this is software or related documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, then the following notice is applicable: U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government. This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently dangerous applications, including applications that may create a risk of personal injury. If you use this software or hardware in dangerous applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications. Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners. Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. UNIX is a registered trademark of The Open Group. This software or hardware and documentation may provide access to or information about content, products, and services from third parties. Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services unless otherwise set forth in an applicable agreement between you and Oracle. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services, except as set forth in an applicable agreement between you and Oracle. Documentation Accessibility For information about Oracle's commitment to accessibility, visit the Oracle Accessibility Program website at Access to Oracle Support Oracle customers that have purchased support have access to electronic support through My Oracle Support. For information, visit ctx=acc&id=info or visit if you are hearing impaired.
4 Référence: E Copyright 2010, 2015, Oracle et/ou ses affiliés. Tous droits réservés. Ce logiciel et la documentation qui l accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des restrictions d utilisation et de divulgation. Sauf stipulation expresse de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire, diffuser, modifier, breveter, transmettre, distribuer, exposer, exécuter, publier ou afficher le logiciel, même partiellement, sous quelque forme et par quelque procédé que ce soit. Par ailleurs, il est interdit de procéder à toute ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à des fins d interopérabilité avec des logiciels tiers ou tel que prescrit par la loi. Les informations fournies dans ce document sont susceptibles de modification sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu elles soient exemptes d erreurs et vous invite, le cas échéant, à lui en faire part par écrit. Si ce logiciel, ou la documentation qui l accompagne, est concédé sous licence au Gouvernement des Etats-Unis, ou à toute entité qui délivre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats-Unis, la notice suivante s applique: U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government. Ce logiciel ou matériel a été développé pour un usage général dans le cadre d applications de gestion des informations. Ce logiciel ou matériel n est pas conçu ni n est destiné à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous utilisez ce logiciel ou matériel dans le cadre d applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de sauvegarde, de redondance et autres mesures nécessaires à son utilisation dans des conditions optimales de sécurité. Oracle Corporation et ses affiliés déclinent toute responsabilité quant aux dommages causés par l utilisation de ce logiciel ou matériel pour ce type d applications. Oracle et Java sont des marques déposées d Oracle Corporation et/ou de ses affiliés. Tout autre nom mentionné peut correspondre à des marques appartenant à d autres propriétaires qu Oracle. Intel et Intel Xeon sont des marques ou des marques déposées d Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des marques déposées de SPARC International, Inc. AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d Advanced Micro Devices. UNIX est une marque déposée d The Open Group. Ce logiciel ou matériel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant accès à des contenus, des produits et des services émanant de tiers. Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou services émanant de tiers, sauf mention contraire stipulée dans un contrat entre vous et Oracle. En aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts occasionnés ou des dommages causés par l accès à des contenus, produits ou services tiers, ou à leur utilisation, sauf mention contraire stipulée dans un contrat entre vous et Oracle. Accessibilité de la documentation Pour plus d informations sur l engagement d Oracle pour l accessibilité à la documentation, visitez le site Web Oracle Accessibility Program, à l'adresse pls/topic/lookup?ctx=acc&id=docacc. Accès au support électronique Les clients Oracle qui ont souscrit un contrat de support ont accès au support électronique via My Oracle Support. Pour plus d'informations, visitez le site pls/topic/lookup?ctx=acc&id=info ou le site si vous êtes malentendant.
5 Contents Using This Documentation... 7 Product Documentation Library... 7 Acronyms and Abbreviations... 7 CLI Command Modes... 7 Feedback... 8 RIP Overview... 9 Protocol Description... 9 Configuring the RIP Topology Example... 9 RIP Topology RIP Topology Configure Switch Configure Switch Configure Switch General Configurations Managing RIP Enable RIP Disable RIP Enabling RIP on an IP Network Configuring RIP Security Enable RIP Security Disable RIP Security Configuring the RIP Packet Retransmission Interval and Retry Count Set the RIP Packet Retransmission Interval and Retry Count Reset the Retransmission Interval and Retry Count Configuring RIP Neighbors Add a RIP Neighbor Remove a RIP Neighbor Configuring the RIP Passive Interface
6 Contents Enable the RIP Passive Interface Disable the RIP Passive Interface Configuring the Output Delay Enable the Output Delay Disable the Output Delay Configuring Redistribution Enable Redistribution Test Redistribution Disable Redistribution Configuring the Default Metric Set the Default Metric Test the Default Metric Reset the Default Metric Managing the auto-summary Option Disable the auto-summary Option Enable the auto-summary Option Configuring Interface-Specific RIP Parameters Configuring Interface-Specific Authentication Configuring the RIP Default Route Propagation Configuring the Version for Receiving RIP Advertisement Configuring the Summary Address Configure Basic Timers Configuring the split-horizon Option Configuring the Debug Level for RIP Enable Debug Disable Debug Sun Ethernet Fabric Operating System July 2015
7 Using This Documentation Overview Describes RIP topologies and how to configure RIP software Audience Users implementing RIP protocol with other protocols in the router stack Required Knowledge Basic knowledge of the RIP protocol Product Documentation Library Documentation and resources for this product and related products are available at: Acronyms and Abbreviations Acronym or Abbreviation CLI IETF IGP Oracle ILOM LAN NEM RIP SEFOS Explanation Command-line interface Internet Engineering Task Force Internet Gateway Protocol Oracle Integrated Lights Out Management Local area network Network Express Module Routing Information Protocol Sun Ethernet Fabric Operating System CLI Command Modes The following table lists the configuration modes used in this document with their access and exit methods. Using This Documentation 7
8 Feedback Command Mode Access Method Prompt Exit Method User EXEC Privileged EXEC Global Configuration Interface Configuration Access SEFOS from Oracle ILOM with read-only rights (privilege level 1). Access SEFOS from Oracle ILOM with full administrative rights (privilege level 15). From Privileged EXEC mode, use the configure terminal command. From Global Configuration mode, use the interface interface-type interfaceid command. SEFOS> SEFOS# SEFOS(config)# SEFOS(config-if)# Use logout or exit to return to the Oracle ILOM prompt. Use the logout or exit command to return to the Oracle ILOM prompt. Use the end command to return to Privileged EXEC mode. Use the exit command to return to Global Configuration mode, or use the end command to return to Privileged EXEC mode. Feedback Provide feedback on this documentation at: 8 Sun Ethernet Fabric Operating System July 2015
9 RIP Overview This section describes the RIP protocol and how to configure the example topology: Protocol Description on page 9 Configuring the RIP Topology Example on page 9 Protocol Description RIP is a widely-used protocol for managing router information within a self-contained network such as a corporate local area network or an interconnected group of such LANs. RIP is classified by the IETF as one of several IGPs. RIP sends routing-update messages at regular intervals and when the network topology changes. When a router receives a routing update that includes changes to an entry, the router updates its routing table to reflect the new route. The metric value for the path is increased by 1, and the sender is indicated as the next hop. RIP routers maintain only the best route (the route with the lowest metric value) to a destination. After updating its routing table, the router immediately begins transmitting routing updates to inform other network routers of the change. These updates are sent independently of the regularly scheduled updates that RIP routers send. RIP uses a hop count as a way to determine network distance. Configuring the RIP Topology Example This section describes two RIP topology examples. These configurations are examples only. Variables such as interfaces, IP addresses, and other ID numbers might be different based on your site configuration. However, before you can configure the RIP software in your environment, you must perform the basic configuration steps that are described in these sections, as they apply to your environment. RIP Topology 1 on page 10 RIP Topology 2 on page 10 Configure Switch 1 on page 11 Configure Switch 2 on page 11 RIP Overview 9
10 Configuring the RIP Topology Example Configure Switch 3 on page 12 RIP Topology 1 This illustration shows one RIP topology in which two switches are connected over a common interface and share VLAN 1. Switch 1 also has VLAN 2 and VLAN 5 configured, and switch 2 has VLAN 3 and VLAN 5 configured. RIP Topology 2 This illustration shows a second RIP topology in which all three switches are connected over a common interface in VLAN 1. Switch 1 also has VLAN 2 configured. Switch 3 has VLAN 4 configured, and switch 2 has VLAN 3 configured. 10 Sun Ethernet Fabric Operating System July 2015
11 Configure Switch 1 Configure Switch 1 Use the following commands to configure VLAN 1 and VLAN 2 on switch 1 in the example topologies. Configure switch 1. SEFOS(config)# set gvrp disable SEFOS(config)# set gmrp disable SEFOS(config-if)# shutdown SEFOS(config-if)# ip address SEFOS(config-if)# no shutdown SEFOS(config-if)# exit SEFOS(config)# vlan 1 SEFOS(config-vlan)# ports extreme-ethernet 0/1 untagged extreme-ethernet 0/1 SEFOS(config-vlan)# exit SEFOS(config)# interface vlan 2 SEFOS(config-if)# shutdown SEFOS(config-if)# ip address SEFOS(config-if)# no shutdown SEFOS(config-if)# exit SEFOS(config)# vlan 2 SEFOS(config-vlan)# ports extreme-ethernet 0/2 untagged extreme-ethernet 0/2 SEFOS(config-vlan)# exit SEFOS(config)# interface extreme-ethernet 0/2 SEFOS(config-if)# switchport pvid 2 SEFOS(config-if)# no shutdown SEFOS(config-if)# exit Configure Switch 2 Use the following commands to configure VLAN 1 and VLAN 3 on switch 2 in the example topologies. Configure switch 2. SEFOS(config)# set gvrp disable SEFOS(config)# set gmrp disable SEFOS(config-if)# shutdown SEFOS(config-if)# ip address SEFOS(config-if)# no shutdown RIP Overview 11
12 Configure Switch 3 SEFOS(config-if)# exit SEFOS(config)# vlan 1 SEFOS(config-vlan)# ports extreme-ethernet 0/1 untagged extreme-ethernet 0/1 SEFOS(config-vlan)# exit SEFOS(config)# interface vlan 3 SEFOS(config-if)# shutdown SEFOS(config-if)# ip address SEFOS(config-if)# no shutdown SEFOS(config-if)# exit SEFOS(config)# vlan 3 SEFOS(config-vlan)# ports extreme-ethernet 0/3 untagged extreme-ethernet 0/3 SEFOS(config-vlan)# exit SEFOS(config)# interface extreme-ethernet 0/3 SEFOS(config-if)# switchport pvid 3 SEFOS(config-if)# no shutdown SEFOS(config-if)# exit Configure Switch 3 Use the following commands to configure VLAN 1 and VLAN 4 on switch 3 in the example topologies. Configure switch 3. SEFOS(config)# set gvrp disable SEFOS(config)# set gmrp disable SEFOS(config-if)# shutdown SEFOS(config-if)# ip address SEFOS(config-if)# no shutdown SEFOS(config-if)# exit SEFOS(config)# vlan 1 SEFOS(config-vlan)# ports extreme-ethernet 0/1 untagged extreme-ethernet 0/1 SEFOS(config-vlan)# exit SEFOS(config)# interface vlan 4 SEFOS(config-if)# shutdown SEFOS(config-if)# ip address SEFOS(config-if)# no shutdown SEFOS(config-if)# exit SEFOS(config)# vlan 4 SEFOS(config-vlan)# ports extreme-ethernet 0/4 untagged extreme-ethernet 0/4 SEFOS(config-vlan)# exit SEFOS(config)# interface extreme-ethernet 0/4 SEFOS(config-if)# switchport pvid 4 SEFOS(config-if)# no shutdown 12 Sun Ethernet Fabric Operating System July 2015
13 Configure Switch 3 SEFOS(config-if)# exit RIP Overview 13
14 14 Sun Ethernet Fabric Operating System July 2015
15 General Configurations This section contains procedures for configuring RIP in SEFOS. See Configuring the RIP Topology Example on page 9 for descriptions of the topologies that are referenced in the procedures. Before you can configure RIP, you must configure the switches in your environment. To configure switch 1, see Configure Switch 1 on page 11. To configure switch 2, see Configure Switch 2 on page 11, and to configure switch 3, see Configure Switch 3 on page 12. RIP is disabled by default. Managing RIP on page 15 Configuring RIP Security on page 17 Configuring the RIP Packet Retransmission Interval and Retry Count on page 18 Configuring RIP Neighbors on page 20 Configuring the RIP Passive Interface on page 21 Configuring the Output Delay on page 23 Configuring Redistribution on page 25 Configuring the Default Metric on page 28 Managing the auto-summary Option on page 31 Configuring Interface-Specific RIP Parameters on page 33 Configuring the Debug Level for RIP on page 46 Managing RIP Before you can enable RIP, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Enable RIP on page 16 Disable RIP on page 16 Enabling RIP on an IP Network on page 16 General Configurations 15
16 Enable RIP Enable RIP 1. On the switch, enter Global Configuration mode. 2. Enable RIP. SEFOS(config-router)# exit Disable RIP 1. On the switch, enter Global Configuration mode. 2. Disable RIP. SEFOS(config)# no router rip SEFOS(config)# exit Enabling RIP on an IP Network 1. Enter Global Configuration mode. 2. On switch 1, enable RIP for the VLAN 1 interface. SEFOS(config-router)# exit 3. Review the RIP interface. SEFOS# show ip rip statistics 16 Sun Ethernet Fabric Operating System July 2015
17 Configuring RIP Security RIP Global Statistics: Total number of route changes is 0 Total number of queries responded is 0 Total number of dropped packets is 0 RIP Interface Statistics: Interface Periodic BadRoutes Triggered BadPackets Admin IP Address Updates Sent Received Updates Sent Received Status Enabled 4. Review the RIP route. SEFOS# show ip rip database /8[1] summary route /16 directly connected, vlan1 Configuring RIP Security By default, RIP security is disabled. Before you can enable RIP security, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Enable RIP Security on page 17 Disable RIP Security on page 18 Enable RIP Security 1. Enter the configuration mode for the router. 2. Enable RIP security in switch 1. SEFOS(config-router)# ip rip security minimum SEFOS(config-router)# exit General Configurations 17
18 Disable RIP Security Disable RIP Security 1. Enter the configuration mode for the router. 2. Disable RIP security. SEFOS(config-router)# no ip rip security SEFOS(config-router)# exit Configuring the RIP Packet Retransmission Interval and Retry Count Before you can configure the retransmission level or retry count, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Set the RIP Packet Retransmission Interval and Retry Count on page 18 Reset the Retransmission Interval and Retry Count on page 19 Set the RIP Packet Retransmission Interval and Retry Count 1. On switch 1, enter the configuration mode for the router. 2. Set the retransmission interval (10 seconds in this example). SEFOS(config-router)# ip rip retransmission interval Set the retry count (20 in this example). SEFOS(config-router)# ip rip retransmission retries Sun Ethernet Fabric Operating System July 2015
19 Reset the Retransmission Interval and Retry Count 4. Review the configuration information. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Minimum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 10 seconds Number of retransmission retries is 20 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination Reset the Retransmission Interval and Retry Count 1. On switch 1, enter the configuration mode for the router. 2. Reset the retransmission interval and retry count. SEFOS(config-router)# no ip rip retransmission interval SEFOS(config-router)# no ip rip retransmission retries SEFOS(config-router)# end 3. Review the configuration information. General Configurations 19
20 Configuring RIP Neighbors SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination Configuring RIP Neighbors Before you can enable RIP neighbors, you must configure your environment. The procedures in this section are based on RIP Topology 2 on page 10. For instructions on how to configure switch 1, see page 8. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. For instructions on how to configure switch 3, see Configure Switch 3 on page 12. Add a RIP Neighbor on page 20 Remove a RIP Neighbor on page 21 Add a RIP Neighbor In this example, switch 2 is added to switch On switch 1, enter the configuration mode for the router. 20 Sun Ethernet Fabric Operating System July 2015
21 Remove a RIP Neighbor 2. Add the switch 2 as a neighbor. SEFOS(config-router)# neighbor SEFOS(config-router)# end In switch 1, you should be able to view only the routes that are sent as RIP updates from the neighbor router (switch 2 at ). Remove a RIP Neighbor In this example, switch 2 is removed from switch On switch 1, enter the configuration mode for the router. 2. Delete the configured RIP neighbor. SEFOS(config-router)# no neighbor SEFOS(config-router)# end In switch 1, you should be able to view the routes that are sent as RIP updates from both of the neighbor routers (switch 2 at and switch 3 at ). Configuring the RIP Passive Interface Before you can configure the passive interface, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Enable the RIP Passive Interface on page 21 Disable the RIP Passive Interface on page 22 Enable the RIP Passive Interface 1. On switch 1, enter the configuration mode for the router. General Configurations 21
22 Disable the RIP Passive Interface 2. Enable the passive interface for VLAN 1. SEFOS(config-router)# passive-interface vlan 1 SEFOS(config-router)# exit 3. Review the passive interface configuration information. SEFOS# show ip rip statistics RIP Global Statistics: Total number of route changes is 0 Total number of queries responded is 0 Total number of dropped packets is 0 RIP Interface Statistics: Interface Periodic BadRoutes Triggered BadPackets Admin IP Address Updates Sent Received Updates Sent Received Status Passive No routing updates are sent over the passive interface (VLAN 1). Disable the RIP Passive Interface 1. On switch 1, enter the configuration mode for the router. 2. Disable the passive interface status for VLAN 1. SEFOS(config-router)# no passive-interface vlan 1 SEFOS(config-router)# exit 3. Review the RIP interface for the periodic updates sent over the interface. 22 Sun Ethernet Fabric Operating System July 2015
23 Configuring the Output Delay SEFOS# show ip rip statistics RIP Global Statistics: Total number of route changes is 0 Total number of queries responded is 0 Total number of dropped packets is 0 RIP Interface Statistics: Interface Periodic BadRoutes Triggered BadPackets Admin IP Address Updates Sent Received Updates Sent Received Status Enabled Configuring the Output Delay Before you can configure the output delay, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Enable the Output Delay on page 23 Disable the Output Delay on page 24 Enable the Output Delay 1. On switch 1, enter the configuration mode for the router. 2. Enable the output delay feature. SEFOS(config-router)# output-delay SEFOS(config-router)# end 3. Review the enabled output delay. SEFOS# show ip protocols Routing Protocol is rip Vrf default General Configurations 23
24 Disable the Output Delay RIP2 security level is Maximum Redistributing : rip Output Delay is enabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination Disable the Output Delay 1. On switch 1, enter the configuration mode for the router. 2. Disable the output delay. SEFOS(config-router)# no output-delay SEFOS(config-router)# end 3. Review the output delay. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled 24 Sun Ethernet Fabric Operating System July 2015
25 Configuring Redistribution Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination Configuring Redistribution Before you can configure redistribution, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Enable Redistribution on page 25 Test Redistribution on page 25 Disable Redistribution on page 27 Enable Redistribution 1. On switch 1, enter the configuration mode for the router. 2. Enable redistribution. SEFOS(config-router)# redistribute static SEFOS(config-router)# end Test Redistribution 1. On switch 1, enter the configuration mode for the router. General Configurations 25
26 Test Redistribution 2. Enable redistribution. SEFOS(config-router)# redistribute static SEFOS(config-router)# exit 3. Add static routes. SEFOS(config)# ip route vlan 2 SEFOS(config)# ip route vlan 2 SEFOS(config)# ip route vlan 2 SEFOS(config)# ip route vlan 2 SEFOS(config)# end 4. On switch 2, test the redistribution. SEFOS(config-router)# network SEFOS(config-router)# end 5. Review the redistribution of static routes on switch 1. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip, static Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds 26 Sun Ethernet Fabric Operating System July 2015
27 Disable Redistribution Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination 6. On switch 2, review the RIP route entries for the static routes that were added in switch 1. In switch 1, static routes with the metric of 3 are redistributed into the RIP domain. The following output shows the redistributed static routes with the metric of 4. SEFOS# show ip rip database /8 [1] auto-summary /16 [1] directly connected, vlan /8 [4] auto-summary /8 [4] via , vlan /8 [4] auto-summary /8 [4] via , vlan /8 [4] auto-summary /8 [4] via , vlan /8 [4] auto-summary /8 [4] via , vlan1 7. Review the IP routing table on switch 2. SEFOS# show ip route C /16 is directly connected, vlan1 C /24 is directly connected, vlan3 R /8 [4] via R /8 [4] via R /8 [4] via R /8 [4] via Disable Redistribution 1. On switch 1, enter the configuration mode for the router. 2. Disable the output delay. SEFOS(config-router)# no redistribute static SEFOS(config-router)# end General Configurations 27
28 Configuring the Default Metric 3. On switch 2, review the RIP route entries for the static routes that were added in switch 1. The routes were made unreachable with a metric as infinity (16). The static routes are redistributed into the RIP domain. SEFOS# show ip rip database /8 [1] auto-summary /16 [1] directly connected, vlan /8 [16] via , vlan /8 [16] via , vlan /8 [16] via , vlan /8 [16] via , vlan1 4. On switch 2, review the RIP route entries for the redistributed static routes that were deleted from the IP routing table. SEFOS# show ip route C /16 is directly connected, vlan1 C /24 is directly connected, vlan3 Configuring the Default Metric Before you can configure the default metric, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Set the Default Metric on page 28 Test the Default Metric on page 29 Reset the Default Metric on page 31 Set the Default Metric 1. On switch 1, enter the configuration mode for the router. 2. Set the default metric value (10 in this example). 28 Sun Ethernet Fabric Operating System July 2015
29 Test the Default Metric SEFOS(config-router)# default-metric 10 SEFOS(config-router)# redistribute static SEFOS(config-router)# end Test the Default Metric 1. On switch 1, enter the configuration mode for the router. 2. Set the default metric value (10 in this example). SEFOS(config-router)# default-metric Configure the redistribution of static routes into the RIP domain. SEFOS(config-router)# redistribute static SEFOS(config-router)# exit 4. Add static routes. SEFOS(config)# ip route vlan 2 SEFOS(config)# ip route vlan 2 SEFOS(config)# ip route vlan 2 SEFOS(config)# ip route vlan 2 SEFOS(config)# end 5. On switch 2, test the default metric. SEFOS# show ip rip database /8 [1] auto-summary /16 [1] directly connected, vlan /8 [11] auto-summary /8 [11] via , vlan /8 [11] auto-summary /8 [11] via , vlan /8 [11] auto-summary /8 [11] via , vlan /8 [11] auto-summary /8 [11] via , vlan1 General Configurations 29
30 Test the Default Metric Review the IP routing table. SEFOS# show ip route C /16 is directly connected, vlan1 C /24 is directly connected, vlan3 R /8 [11] via R /8 [11] via R /8 [11] via R /8 [11] via On switch 1, review the metric for the redistributed RIP route entries. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip, static Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 10 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination 7. On switch 1, review the RIP configuration information. SEFOS# show ip rip database /8 [1] auto-summary /16 [1] directly connected, vlan /8 [10] auto-summary /8 [10] redistributed via /8 [10] auto-summary /8 [10] redistributed via /8 [10] auto-summary 30 Sun Ethernet Fabric Operating System July 2015
31 Reset the Default Metric /8 [10] redistributed via /8 [10] auto-summary /8 [10] redistributed via On switch 1, disable redistribution. SEFOS(config-router)# no redistribute static SEFOS(config-router)# end Reset the Default Metric 1. Reset the default metric for the redistributed routes. SEFOS(config-router)# no default-metric 2. Enable static route redistribution. SEFOS(config-router)# redistribute static SEFOS(config-router)# end 3. On switch 1, review the metric for redistributed RIP route entries. SEFOS# show ip rip database /8 [1] auto-summary /16 [1] directly connected, vlan /8 [3] auto-summary /8 [3] redistributed via /8 [3] auto-summary /8 [3] redistributed via /8 [3] auto-summary /8 [3] redistributed via /8 [3] auto-summary /8 [3] redistributed via Managing the auto-summary Option By default, the auto-summary option is enabled. Before you can manage the auto-summary option, you must configure your environment. The procedures in this section are based on General Configurations 31
32 Disable the auto-summary Option RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Disable the auto-summary Option on page 32 Enable the auto-summary Option on page 33 Disable the auto-summary Option 1. On switch 1, enter the configuration mode for the router. 2. Disable the auto-summary option for RIP routes. SEFOS(config-router)# auto-summary disable 3. Review the disabled option. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is disabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination 32 Sun Ethernet Fabric Operating System July 2015
33 Enable the auto-summary Option Enable the auto-summary Option 1. Enable the auto-summary option in switch 1. SEFOS(config-router)# auto-summary enable SEFOS(config-router)# end 2. Review the configuration information to ensure that the option is enabled. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination Configuring Interface-Specific RIP Parameters You must use the interface mode to configure the parameters. However, before you can configure RIP parameters, you must configure your environment. The procedures in this section are based on RIP Topology 1 on page 10. For instructions on how to configure switch 1, see Configure Switch 1 on page 11. For instructions on how to configure switch 2, see Configure Switch 2 on page 11. Configuring Interface-Specific Authentication on page 34 General Configurations 33
34 Enable Interface-Specific Authentication Configuring the RIP Default Route Propagation on page 36 Configuring the Version for Receiving RIP Advertisement on page 40 Configuring the Summary Address on page 41 Configure Basic Timers on page 43 Configuring the split-horizon Option on page 44 Configuring Interface-Specific Authentication This section contains procedures that explain how to configure interface-specific authentication and the command to disable interface-specific authentication. Enable Interface-Specific Authentication on page 34 Enable Authentication on Both Switches on page 34 Disable Interface-Specific Authentication on page 36 Enable Interface-Specific Authentication 1. Enter the configuration mode for the interface. SEFOS(config-if)# exit 2. Enter the configuration mode for the router. SEFOS(config-router)# exit 3. On switch 1, enable interface-specific authentication on the specific interface. SEFOS(config-if)# ip rip authentication mode md5 key-chain Enable Authentication on Both Switches This task tests the authentication. 1. On switch 1, enter the configuration mode for the router. 34 Sun Ethernet Fabric Operating System July 2015
35 Enable Authentication on Both Switches SEFOS# config terminal SEFOS(config-router)# redistribute all SEFOS(config-router)# exit 2. Enable md5 authentication. SEFOS(config-if)# ip rip authentication mode md5 key-chain SEFOS(config-if)# end 3. On switch 2, enter the configuration mode for the router. SEFOS(config-router)# network SEFOS(config-router)# exit 4. Enable md5 authentication. SEFOS(config-if)# ip rip authentication mode md5 key-chain SEFOS(config-if)# end 5. Review the authentication type in switch 1. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds General Configurations 35
36 Disable Interface-Specific Authentication Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is md5 Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination On switch 2, ensure that all of the RIP packets have authentication information. Disable Interface-Specific Authentication 1. Enter the configuration mode for the interface. SEFOS(config-if)# exit 2. Enter the configuration mode for the router. SEFOS(config-router)# end 3. Disable the authentication. SEFOS(config-if)# no ip rip authentication Configuring the RIP Default Route Propagation This section contains four procedures that explain how to configure and test the default route propagation. Set the Default Route Propagation on page 36 Install the Default Route on page 37 Test the Default Route Origination and Installation on page 37 Disable the Default Route on page 40 Set the Default Route Propagation 1. On switch 1, enter the configuration mode for the interface. 36 Sun Ethernet Fabric Operating System July 2015
37 Install the Default Route SEFOS(config-if)# exit 2. Enter the configuration mode for the router. SEFOS(config-router)# exit 3. Set the default route. SEFOS(config-if)# ip rip default route originate 10 Install the Default Route 1. On switch 1, enter the configuration mode for the interface. SEFOS(config-if)# exit 2. Enter the configuration mode for the router. SEFOS(config-router)# exit 3. Install the default route. SEFOS(config-if)# ip rip default route install Test the Default Route Origination and Installation 1. On switch 1, configure the interface. General Configurations 37
38 Test the Default Route Origination and Installation SEFOS(config-router)# exit 2. Install the default route. SEFOS(config-if)# ip rip default route install SEFOS(config-if)# end 3. On switch 2, configure the interface. SEFOS(config-router)# network SEFOS(config-router)# exit 4. Enable default route origination. SEFOS(config-if)# ip rip default route originate 11 SEFOS(config-if)# end 5. On switch 2, review the RIP response packet sent through the interface in switch 2. The RIP response packets should have a default route. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds 38 Sun Ethernet Fabric Operating System July 2015
39 Test the Default Route Origination and Installation Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Originate default route 6. On switch 1, review the default route with the next hop as (the IP address for switch 2) and a metric of 12 (11+1). SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 2 Authentication type is none Split Horizon with poissoned reverse is enabled Installs default route received Originate default route 7. Review the RIP database. SEFOS# show ip rip database /0 [12] via , vlan /8 [1] auto-summary /16 [1] directly connected, vlan1 8. Review the IP route. SEFOS# show ip route R /0 [12] via C /16 is directly connected, vlan1 C /24 is directly connected, vlan2 General Configurations 39
40 Disable the Default Route Disable the Default Route 1. Enter the configuration mode for the interface. 2. Disable the default route. SEFOS(config-if)# no ip rip default route originate Configuring the Version for Receiving RIP Advertisement This section contains two procedures that explain how to configure the version for receiving RIP advertisements. Set the Version on page 40 Reset the Version on page 41 Set the Version 1. On switch 1, enter the configuration mode for the interface. SEFOS(config-if)# exit 2. Enter the configuration mode for the router. SEFOS(config-router)# exit 3. Set the version for the VLAN interface (1 in this example). SEFOS(config-if)# ip rip receive version 1 4. Review the IP protocol output to ensure that switch 1 receives only RIP version 1 packets over the interface. 40 Sun Ethernet Fabric Operating System July 2015
41 Reset the Version SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip Output Delay is disabled Retransmission timeout interval is 5 seconds Number of retransmission retries is 36 Default metric is 3 Auto-Summarisation of routes is enabled Routing for Networks : Routing Information Sources : Interface Specific Address Summarization : Trusted Neighors : Interface vlan1 Sending updates every 30 seconds Invalid after 180 seconds Flushed after 120 seconds Send version is 1 2, receive version is 1 Authentication type is none Split Horizon with poissoned reverse is enabled Restrcts default route installation Restricts default route origination Reset the Version 1. Enter the configuration mode for the interface. 2. Reset the version. SEFOS(config-if)# no ip rip send version SEFOS(config-if)# no ip rip receive version Configuring the Summary Address This section includes procedures for configuring the summary address. Set the Summary Address on page 42 Test the Summary Address Configuration on page 42 General Configurations 41
42 Set the Summary Address Set the Summary Address 1. On switch 1, enter the configuration mode for the interface. SEFOS(config-if)# exit 2. Disable the auto-summary option for the interface in VLAN 1. SEFOS(config-router)# auto-summary disable SEFOS(config-router)# exit 3. Set the version of the RIP packets to be sent over the VLAN 1 interface. SEFOS(config-if)# ip rip summary-address SEFOS(config-if)# end Test the Summary Address Configuration 1. On switch 1, configure the summary-address option. SEFOS(config-router)# redistribute all 2. Disable the auto-summary option. SEFOS(config-router)# auto-summary disable SEFOS(config-router)# exit 3. Configure the static routes. SEFOS(config-router)# ip route vlan 2 SEFOS(config-router)# ip route vlan 2 SEFOS(config-router)# ip route vlan 2 SEFOS(config-router)# ip route vlan 2 4. Configure the summary address for the VLAN 1 interface ( /8). 42 Sun Ethernet Fabric Operating System July 2015
43 Configure Basic Timers SEFOS(config-if)# ip rip summary-address SEFOS(config-if)# end 5. On switch 2, configure the interface for VLAN 1. SEFOS(config-router)# network SEFOS(config-router)# end Configure Basic Timers 1. On switch 1, enter the configuration mode for the interface. SEFOS(config-if)# exit 2. Enter the configuration mode for the router. SEFOS(config-router)# exit 3. Set the timers. SEFOS(config-if)# timers basic SEFOS(config-if)# end 4. Review the RIP update packets that are sent after 60 seconds and the configured timer values. SEFOS# show ip protocols Routing Protocol is rip Vrf default RIP2 security level is Maximum Redistributing : rip, bgp, connected, ospf, static Output Delay is disabled General Configurations 43
Sun Ethernet Fabric Operating System. RIP Administration Guide
Sun Ethernet Fabric Operating System RIP Administration Guide Part No.: E21705-03 July 2013 Copyright 2010, 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Ethernet Fabric Operating System. LLA Administration Guide
Sun Ethernet Fabric Operating System LLA Administration Guide Part No.: E41876-01 July 2013 Copyright 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation are
More informationSun Ethernet Fabric Operating System. IGMP Administration Guide
Sun Ethernet Fabric Operating System IGMP Administration Guide Part No.: E21712-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Ethernet Fabric Operating System RMON Administration Guide
Sun Ethernet Fabric Operating System RMON Administration Guide Part No: E24665-03 July 2015 Part No: E24665-03 Copyright 2010, 2015, Oracle and/or its affiliates. All rights reserved. This software and
More informationOracle ZFS Storage Appliance Cabling Guide. For ZS3-x, 7x20 Controllers, and DE2-24, Sun Disk Shelves
Oracle ZFS Storage Appliance Cabling Guide For ZS3-x, 7x20 Controllers, and DE2-24, Sun Disk Shelves Part No: E53670-01 June 2014 Copyright 2009, 2014, Oracle and/or its affiliates. All rights reserved.
More informationOracle Dual Port QDR InfiniBand Adapter M3. Product Notes
Oracle Dual Port QDR InfiniBand Adapter M3 Product Notes Part No.: E40986-01 September 2013 Copyright 2013 Oracle and/or its affiliates. All rights reserved. This software and related documentation are
More informationSun Ethernet Fabric Operating System. MLDS Administration Guide
Sun Ethernet Fabric Operating System MLDS Administration Guide Part No.: E25211-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Ethernet Fabric Operating System IGS Administration Guide
Sun Ethernet Fabric Operating System IGS Administration Guide Part No: E21708-03 July 2015 Part No: E21708-03 Copyright 2010, 2015, Oracle and/or its affiliates. All rights reserved. This software and
More informationSun Ethernet Fabric Operating System. OSPF Administration Guide
Sun Ethernet Fabric Operating System OSPF Administration Guide Part No: E21707-03 July 2015 Part No: E21707-03 Copyright 2010, 2015, Oracle and/or its affiliates. All rights reserved. This software and
More informationSun Ethernet Fabric Operating System. OSPF Administration Guide
Sun Ethernet Fabric Operating System OSPF Administration Guide Part No.: E21707-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle ZFS Storage Appliance Simulator Quick Start Guide
Oracle ZFS Storage Appliance Simulator Quick Start Guide March 2015 Part No: E39468-05 This document is a guide to Oracle ZFS Storage Appliance Simulator setup and initial configuration. The Simulator
More informationSun Ethernet Fabric Operating System. DHCP Administration Guide
Sun Ethernet Fabric Operating System DHCP Administration Guide Part No.: E21716-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Ethernet Fabric Operating System. ONET Administration Guide
Sun Ethernet Fabric Operating System ONET Administration Guide Part No.: E26379-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationNetra Blade X3-2B (formerly Sun Netra X6270 M3 Blade) for VMware ESXi. Installation Guide
Netra Blade X3-2B (formerly Sun Netra X6270 M3 Blade) for VMware ESXi Installation Guide Part No.: E28262-04 November 2012 Copyright 2012, Oracle and/or its affiliates. All rights reserved. This software
More informationSun Ethernet Fabric Operating System. IEEE DCBX Administration Guide
Sun Ethernet Fabric Operating System IEEE DCBX Administration Guide Part No.: E41875-02 August 2013 Copyright 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Ethernet Fabric Operating System. IPv6 Administration Guide
Sun Ethernet Fabric Operating System IPv6 Administration Guide Part No.: E24662-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle ZFS Storage Appliance Cabling Guide. For ZS5-x, ZS4-4, ZS3-x, 7x20 Controllers, and DEx-24, Sun Disk Shelves, Release OS8.6.
Oracle ZFS Storage Appliance Cabling Guide For ZS5-x, ZS4-4, ZS3-x, 7x20 Controllers, and DEx-24, Sun Disk Shelves, Release OS8.6.x Part No: E76482-02 December 2016 Oracle ZFS Storage Appliance Cabling
More informationSun Ethernet Fabric Operating System. SLB Administration Guide
Sun Ethernet Fabric Operating System SLB Administration Guide Part No.: E26351-03 July 2013 Copyright 2010, 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle Flash Storage System and Oracle MaxRep for SAN Security Guide
Oracle Flash Storage System and Oracle MaxRep for SAN Security Guide Part Number E56029-01 Oracle Flash Storage System, release 6.1 Oracle MaxRep for SAN, release 3.0 2014 October Oracle Flash Storage
More informationSun Ethernet Fabric Operating System. QoS Administration Guide
Sun Ethernet Fabric Operating System QoS Administration Guide Part No: E20748-03 July 2015 Part No: E20748-03 Copyright 2010, 2015, Oracle and/or its affiliates. All rights reserved. This software and
More informationSun Server X4-2. Installation Guide for Oracle Solaris Operating System
Sun Server X4-2 Installation Guide for Oracle Solaris Operating System Part No.: E38020-03 November 2013 Copyright 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Server X4-2. Security Guide
Sun Server X4-2 Security Guide Part No.: E38042-03 May 2014 Copyright 2013, 2014 Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license
More informationSun Ethernet Fabric Operating System. QoS Administration Guide
Sun Ethernet Fabric Operating System QoS Administration Guide Part No. E20748-02 October 2011 Copyright 2010, 2011, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle MaxMan. User s Guide. Part Number E Oracle MaxMan release October
Oracle MaxMan User s Guide Part Number E54894-01 Oracle MaxMan release 6.1 2014 October Copyright 2005, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationNetra Blade X3-2B (formerly Sun Netra X6270 M3 Blade) for Windows Operating System. Installation Guide
Netra Blade X3-2B (formerly Sun Netra X6270 M3 Blade) for Windows Operating System Installation Guide Part No.: E26412-04 November 2012 Copyright 2012, Oracle and/or its affiliates. All rights reserved.
More informationSun StorageTek 2500 Series Array Firmware Upgrade Guide
Sun StorageTek 2500 Series Array Firmware Upgrade Guide for controller firmware version 7.35 Part No. 820-6362-13 August 2010, Revision D Copyright 2010, Oracle and/or its affiliates. All rights reserved.
More informationSun Server X4-2L. Installation Guide for Windows Server Operating Systems
Sun Server X4-2L Installation Guide for Windows Server Operating Systems Part No.: E38155-03 February 2014 Copyright 2013, 2014, Oracle and/or its affiliates. All rights reserved. This software and related
More informationSun Server X2-4 (formerly Sun Fire X4470 M2) Installation Guide for Oracle Solaris Operating System
Sun Server X2-4 (formerly Sun Fire X4470 M2) Installation Guide for Oracle Solaris Operating System Part No.: E20787-03 September 2012 Copyright 2011, 2012, Oracle and/or its affiliates. All rights reserved.
More informationOracle Fabric Interconnect F2-12 and Oracle F2 I/O Modules Product Notes
Oracle Fabric Interconnect F2-12 and Oracle F2 I/O Modules Product Notes Part No: E74399-02 December 2016 Oracle Fabric Interconnect F2-12 and Oracle F2 I/O Modules Product Notes Part No: E74399-02 Copyright
More informationManaging Boot EnvironmentsWith Oracle Solaris 11 Express
Managing Boot EnvironmentsWith Oracle Solaris 11 Express Part No: 820 6565 12 November 2010 Copyright 2010, Oracle and/or its affiliates. All rights reserved. This software and related documentation are
More informationOracle Hardware Management Pack 2.4 Installation Guide
Oracle Hardware Management Pack 2.4 Installation Guide Part No: E72070-03 September 2017 Oracle Hardware Management Pack 2.4 Installation Guide Part No: E72070-03 Copyright 2017, Oracle and/or its affiliates.
More informationSun Ethernet Fabric Operating System. OSPFv3 Administration Guide
Sun Ethernet Fabric Operating System OSPFv3 Administration Guide Part No.: E25212-02 July 2012 Copyright 2010, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOptimizing the Oracle Solaris Desktop for a Multi-User Environment
Optimizing the Oracle Solaris Desktop for a Multi-User Environment October 2017 Part No: E54805 This article helps Oracle Solaris 11 system administrators to understand how to optimize the Oracle Solaris
More informationOracle Solaris Cluster Data Service for DHCP Guide
Oracle Solaris Cluster Data Service for DHCP Guide Part No: E63543 September 2015 Oracle Solaris Cluster Data Service for DHCP Guide Part No: E63543 Copyright 2010, 2015, Oracle and/or its affiliates.
More informationSun Ethernet Fabric Operating System CLI Reference Manual, Vol. 8
Sun Ethernet Fabric Operating System CLI Reference Manual, Vol. 8 Part No: E60932-02 August 2015 Copyright 2015, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Flash Accelerator F40 PCIe Card. Security Guide
Sun Flash Accelerator F40 PCIe Card Security Guide Part No.: E29743-02 October 2013 Copyright 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided
More informationSun Server X3-2L (formerly Sun Fire X4270 M3) Administration Guide
Sun Server X3-2L (formerly Sun Fire X4270 M3) Administration Guide Part No.: E23402-10 April 2014 Copyright 2012, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Network QDR InfiniBand Gateway Switch
Sun Network QDR InfiniBand Gateway Switch Service Manual for Firmware Version 2.0 Part No.: E26710-01 November 2011, Revision A Copyright 2011, Oracle and/or its affiliates. All rights reserved. This software
More informationOracle InfiniBand Switch IS2-46 Product Notes
Oracle InfiniBand Switch IS2-46 Product Notes Part No: E65870-01 September 2016 Oracle InfiniBand Switch IS2-46 Product Notes Part No: E65870-01 Copyright 2016, Oracle and/or its affiliates. All rights
More informationNetra Server X5-2 Operating System Installation Guide
Netra Server X5-2 Operating System Installation Guide Part No: E53599-03 October 2016 Netra Server X5-2 Operating System Installation Guide Part No: E53599-03 Copyright 2015, 2016, Oracle and/or its affiliates.
More informationOracle Solaris 11.2 Desktop User's Guide
Oracle Solaris 11.2 Desktop User's Guide Part No: E36851 July 2014 Copyright 2011, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a
More informationOracle Advanced Support Gateway Security Guide
Oracle Advanced Support Security Guide Part No: E40643-19 October 2017 Security Guide Part No: E40643-19 Copyright 2017, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle SuperCluster M8 and SuperCluster M7 Overview Guide
Oracle SuperCluster M8 and SuperCluster M7 Overview Guide Part No: E58633-10 March 2018 Oracle SuperCluster M8 and SuperCluster M7 Overview Guide Part No: E58633-10 Copyright 2015, 2018, Oracle and/or
More informationSun Server X4-2. Installation Guide for VMware ESXi
Sun Server X4-2 Installation Guide for VMware ESXi Part No.: E38024-03 February 2014 Copyright 2013, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation are
More informationJavaTest Harness 4.4. JavaTest Agent User s Guide
JavaTest Harness 4.4 JavaTest Agent User s Guide May 2011 Copyright 2005, 2011, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement
More informationSPARC T7-1 Server Installation Guide
SPARC T7-1 Server Installation Guide Part No: E54979-02 July 2017 SPARC T7-1 Server Installation Guide Part No: E54979-02 Copyright 2015, 2017, Oracle and/or its affiliates. All rights reserved. This
More informationSun Ethernet Fabric Operating System. VLAN Administration Guide
Sun Ethernet Fabric Operating System VLAN Administration Guide Part No. E20769-02 October 2011 Copyright 2010, 2011, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle Server Management Agent for Oracle Solaris 11.2 User's Guide
Oracle Server Management Agent for Oracle Solaris 11.2 User's Guide Part No: E51811-05 June 2015 Part No: E51811-05 Copyright 2014, 2015, Oracle and/or its affiliates. All rights reserved. This software
More informationSun Network QDR InfiniBand Gateway Switch
Sun Network QDR InfiniBand Gateway Switch Service Manual Part No. 821-1188-11 June 2011, Revision A Copyright 2011, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationTrusted Extensions User's Guide
Trusted Extensions User's Guide Part No: E36841 July 2014 Copyright 1997, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement
More informationPart No September 2010, Revision A. Sun Blade6000 Virtualized Multi- Fabric 10GbE Network Express Module Product Notes
Part No. 820-6584-17 September 2010, Revision A Sun Blade6000 Virtualized Multi- Fabric 10GbE Network Express Module Product Notes Copyright 2009, 2010, Oracle and/or its affiliates. All rights reserved.
More informationOracle Server X6-2 Security Guide
Oracle Server X6-2 Security Guide Part No: E62163-01 April 2016 Oracle Server X6-2 Security Guide Part No: E62163-01 Copyright 2016, Oracle and/or its affiliates. All rights reserved. This software and
More informationOracle Solaris Studio 12.4: Performance Analyzer Tutorials
Oracle Solaris Studio 12.4: Performance Analyzer Tutorials Part No: E37087 December 2014 Copyright 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided
More informationOracle Solaris Cluster Data Services Planning and Administration Guide
Oracle Solaris Cluster Data Services Planning and Administration Guide Part No: E39648 September 2014, E39648 02 Copyright 2000, 2014, Oracle and/or its affiliates. All rights reserved. This software
More informationOracle Solaris Cluster With Network- Attached Storage Device Manual
Oracle Solaris Cluster With Network- Attached Storage Device Manual Part No: E39824 July 2014, E39824-01 Copyright 2000, 2014, Oracle and/or its affiliates. All rights reserved. This software and related
More informationSPARC M8 and SPARC M7 Servers Product Notes
SPARC M8 and SPARC M7 Servers Product Notes Part No: E55216-13 October 2017 SPARC M8 and SPARC M7 Servers Product Notes Part No: E55216-13 Copyright 2015, 2017, Oracle and/or its affiliates. All rights
More informationInstalling Oracle Solaris 11.3 Systems
Installing Oracle Solaris 11.3 Systems Part No: E54756 September 2018 Installing Oracle Solaris 11.3 Systems Part No: E54756 Copyright 2011, 2018, Oracle and/or its affiliates. All rights reserved. This
More informationOracle Server X5-4 Installation Guide for Windows Operating Systems
Oracle Server X5-4 Installation Guide for Windows Operating Systems Part No: E56394-03 December 2015 Oracle Server X5-4 Installation Guide for Windows Operating Systems Part No: E56394-03 Copyright 2015,
More informationSun Storage Common Array Manager. Array Administration Guide, Version 6.9.0
Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0 Part No.: E24011-01 December 2011 Copyright 2007, 2011, Oracle and/or its affiliates. All rights reserved. This software and related
More informationOracle Solaris Cluster 4 Compatibility Guide
Oracle Solaris Cluster 4 Compatibility Guide Part No: E87540 September 2018 Oracle Solaris Cluster 4 Compatibility Guide Part No: E87540 Copyright 2018, Oracle and/or its affiliates. All rights reserved.
More informationSPARC and Netra SPARC T5 Series Servers Administration Guide
SPARC and Netra SPARC T5 Series Servers Administration Guide Part No: E29502-10 August 2016 SPARC and Netra SPARC T5 Series Servers Administration Guide Part No: E29502-10 Copyright 2013, 2016, Oracle
More informationStorageTek 4 Gb FC Dual Port ExpressModule HBA From Emulex. Installation Guide For HBA Models SG-XPCIE2FC- EB4-Z and SG-PCIE2FC-EB4-Z
StorageTek 4 Gb FC Dual Port ExpressModule HBA From Emulex Installation Guide For HBA Models SG-XPCIE2FC- EB4-Z and SG-PCIE2FC-EB4-Z Part No.: E41889-01 July 2013 Copyright 2007, 2013, Oracle and/or its
More informationOracle ILOM Security Guide For Firmware Releases 3.x and 4.x
Oracle ILOM Security Guide For Firmware Releases 3.x and 4.x Part No: E37451-17 December 2017 Oracle ILOM Security Guide For Firmware Releases 3.x and 4.x Part No: E37451-17 Copyright 2012, 2017, Oracle
More informationOracle Server Management Agents User's Guide
Oracle Server Management Agents User's Guide Part No: E52098-08 January 2017 Oracle Server Management Agents User's Guide Part No: E52098-08 Copyright 2014, 2017, Oracle and/or its affiliates. All rights
More informationOracle Server Management Agent for Oracle Solaris 11.3 User's Guide
Oracle Server Management Agent for Oracle Solaris 11.3 User's Guide Part No: E64581-03 October 2017 Oracle Server Management Agent for Oracle Solaris 11.3 User's Guide Part No: E64581-03 Copyright 2014,
More informationOracle Integrated Lights Out Manager (ILOM) 3.1. Security Guide
Oracle Integrated Lights Out Manager (ILOM) 3.1 Security Guide Part No.: E24526-03 August 2013 Copyright 2012, 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle X4 Series Servers Administration Guide
Oracle X4 Series Servers Administration Guide Part No: E37044-10 April 2016 Oracle X4 Series Servers Administration Guide Part No: E37044-10 Copyright 2014, 2016, Oracle and/or its affiliates. All rights
More informationSun Ethernet Fabric Operating System CLI Reference Manual, Vol. 6
Sun Ethernet Fabric Operating System CLI Reference Manual, Vol. 6 Part No: E60930-02 August 2015 Copyright 2015, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Server X4-4 Installation Guide for Oracle Solaris Operating System
Sun Server X4-4 Installation Guide for Oracle Solaris Operating System Part No: E38216-03 October 2015 Sun Server X4-4 Installation Guide for Oracle Solaris Operating System Part No: E38216-03 Copyright
More informationOracle Solaris 11.3 Desktop User's Guide
Oracle Solaris 11.3 Desktop User's Guide Part No: E54809 October 2017 Oracle Solaris 11.3 Desktop User's Guide Part No: E54809 Copyright 2011, 2017, Oracle and/or its affiliates. All rights reserved.
More informationSun Storage 2500-M2 Arrays. Hardware Installation Guide
Sun Storage 2500-M2 Arrays Hardware Installation Guide Part No.: E20740-01 June 2011 Copyright 2011, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided
More informationOracle Developer Studio 12.5: Installation Guide
Oracle Developer Studio 12.5: Installation Guide Part No: E60743 July 2016 Oracle Developer Studio 12.5: Installation Guide Part No: E60743 Copyright 2014, 2016, Oracle and/or its affiliates. All rights
More informationOracle Server X5-8 Installation Guide for Linux Operating Systems
Oracle Server X5-8 Installation Guide for Linux Operating Systems Part No: E56308-03 December 2015 Oracle Server X5-8 Installation Guide for Linux Operating Systems Part No: E56308-03 Copyright 2015,
More informationOracle Integrated Lights Out Manager (ILOM) 3.1. Configuration and Maintenance Guide
Oracle Integrated Lights Out Manager (ILOM) 3.1 Configuration and Maintenance Guide Part No.: E24522-09 February 2014 Copyright 2012, 2014, Oracle and/or its affiliates. All rights reserved. This software
More informationOracle Virtual Networking Host Drivers for VMware ESX 6.0 Release Notes
Oracle Virtual Networking Host Drivers for VMware ESX 6.0 Release Notes Part No: E64239-03 July 2016 Oracle Virtual Networking Host Drivers for VMware ESX 6.0 Release Notes Part No: E64239-03 Copyright
More informationManaging Network Datalinks in Oracle Solaris 11.4
Managing Network Datalinks in Oracle Solaris 11.4 Part No: E60990 August 2018 Managing Network Datalinks in Oracle Solaris 11.4 Part No: E60990 Copyright 2011, 2018, Oracle and/or its affiliates. All
More informationOracle Secure Global Desktop
Oracle Secure Global Desktop Installation Guide for Version 4.6 Part No. 821-1927-10 August 2010, Revision 01 Copyright 2010, Oracle and/or its affiliates. All rights reserved. This software and related
More informationOracle Integrated Lights Out Manager (ILOM) 3.1. Security Guide
Oracle Integrated Lights Out Manager (ILOM) 3.1 Security Guide Part No.: E24526-02 July 2012 Copyright 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation are
More informationOracle Dual Port QDR InfiniBand Adapter M3. User s Guide
Oracle Dual Port QDR InfiniBand Adapter M3 User s Guide Part No.: E40987-01 September 2013 Copyright 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation are
More informationNetra SPARC T4-2 Server. Product Notes
Netra SPARC T4-2 Server Product Notes Part No.: E21899-04 December 2012 Copyright 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license
More informationTrusted Extensions User's Guide
Trusted Extensions User's Guide Part No: E54844 October 2017 Trusted Extensions User's Guide Part No: E54844 Copyright 1997, 2017, Oracle and/or its affiliates. All rights reserved. This software and
More informationCreating and Administering Oracle Solaris 11.2 Boot Environments
Creating and Administering Oracle Solaris 11.2 Boot Environments Part No: E36803 July 2014 Copyright 2008, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationSun Storage F5100 Flash Array
Sun Storage F5100 Flash Array Product Notes Part No.: E21408-04 February 2012, Revision A Copyright 2009, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle Flash Accelerator F160 PCIe Card and Oracle 1.6 TB NVMe SSD Product Notes
Oracle Flash Accelerator F160 PCIe Card and Oracle 1.6 TB NVMe SSD Product Notes Part No: E54945-08 April 2017 Oracle Flash Accelerator F160 PCIe Card and Oracle 1.6 TB NVMe SSD Product Notes Part No:
More informationOracle Database Appliance Owner's Guide
Oracle Database Appliance Owner's Guide Part No: E80975-01 December 2016 Oracle Database Appliance Owner's Guide Part No: E80975-01 Copyright 2016, Oracle and/or its affiliates. All rights reserved. This
More informationOracle Solaris Studio 12.4: IDE Quick Start Tutorial
Oracle Solaris Studio 12.4: IDE Quick Start Tutorial Part No: E37083 October 2014 Copyright 2013, 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided
More informationSun Blade 6048 Modular System. Product Notes
Sun Blade 6048 Modular System Product Notes Part No. E23072-01 April 2011 Copyright 2007, 2011, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under
More informationAdding Custom Data to Oracle Solaris 11.4 Analytics
Adding Custom Data to Oracle Solaris 11.4 Analytics Part No: E61819 Draft 2018-01-30-16:53:42-08:00 Draft 2018-01-30-16:53:42-08:00 Adding Custom Data to Oracle Solaris 11.4 Analytics Part No: E61819 Copyright
More informationSun Blade X6275 M2 Server Module Installation Guide for Linux Operating Systems
Sun Blade X6275 M2 Server Module Installation Guide for Linux Operating Systems Part No: 821 1086 January 2011, Rev A Copyright 2010, 2011, Oracle and/or its affiliates. All rights reserved. License Restrictions
More informationOracle ILOM Administrator's Guide for Configuration and Maintenance Firmware Release 3.2.x
Oracle ILOM Administrator's Guide for Configuration and Maintenance Firmware Release 3.2.x Part No: E37446-21 January 2017 Oracle ILOM Administrator's Guide for Configuration and Maintenance Firmware
More informationIntroduction to Oracle Solaris 11 Networking
Introduction to Oracle Solaris 11 Networking Part No: E28986 01 October 2012 Copyright 2011, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided
More informationOracle ZFS Storage Appliance Installation Guide. For ZS5-x, ZS4-4, ZS3-x, 7x20 Controllers, and DEx-24, Sun Disk Shelves, Release OS8.6.
Oracle ZFS Storage Appliance Installation Guide For ZS5-x, ZS4-4, ZS3-x, 7x20 Controllers, and DEx-24, Sun Disk Shelves, Release OS8.6.x Part No: E76481-02 December 2016 Oracle ZFS Storage Appliance Installation
More informationSun Server X2-4 (formerly Sun Fire X4470 M2) Installation Guide for Linux Operating Systems
Sun Server X2-4 (formerly Sun Fire X4470 M2) Installation Guide for Linux Operating Systems Part No.: E20788-03 September 2012 Copyright 2011, 2012, Oracle and/or its affiliates. All rights reserved. This
More informationSun Blade 6000 Modular System
Sun Blade 6000 Modular System Service Manual Part No.: 820-0051-11 December 2010, Revision A Copyright 2007, 2010, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle Integrated Lights Out Manager (ILOM) 3.0
Oracle Integrated Lights Out Manager (ILOM) 3.0 Web Interface Procedures Guide Part No. 820-6411-12 October 2010, Revision A Copyright 2008, 2010, Oracle and/or its affiliates. All rights reserved. This
More informationOracle Fabric Manager Release Notes
Oracle Fabric Manager Release Notes Part No.: E52314-02 September 2014 Copyright 2014, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license
More informationCreating and Administering Oracle Solaris 11.1 Boot Environments
Creating and Administering Oracle Solaris 11.1 Boot Environments Part No: E29052 01 October 2012 Copyright 2008, 2012, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle Solaris Cluster Data Service for SAP NetWeaver Guide
Oracle Solaris Cluster Data Service for SAP NetWeaver Guide Part No: E29440 July 2013, E29440 01 Copyright 2012, 2013, Oracle and/or its affiliates. All rights reserved. This software and related documentation
More informationOracle Solaris Cluster Data Service for Oracle iplanetweb Server Guide
Oracle Solaris Cluster Data Service for Oracle iplanetweb Server Guide Part No: E35571 October 2012, E35571 01 Copyright 2009, 2012, Oracle and/or its affiliates. All rights reserved. This software and
More informationOracle Solaris Cluster Data Service for Oracle External Proxy Guide
Oracle Solaris Cluster Data Service for Oracle External Proxy Guide Part No: E52343 July 2014, E52343-01 Copyright 2012, 2014, Oracle and/or its affiliates. All rights reserved. This software and related
More information