B: Modbus Map and Retrieving Logs

Size: px
Start display at page:

Download "B: Modbus Map and Retrieving Logs"

Transcription

1 B: Modbus Map and Retrieving Logs B.: Introduction Communicator EXT User Manual B.: Modbus Register Map Sections B.3: Data Formats #

2 B.4: Floating Point Values The formula to interpret a Floating Point Value is: sign exponent-7 sign Formula Explanation: #

3 NOTES: B.5: Retrieving Logs Using the Shark 00 Meter's Modbus Map NOTES: #

4 B.5.: Data Formats B.5.: Shark 00 Meter Logs System Event (0) NOTE: Alarm Log (): #

5 Historical Log () NOTE: Historical Log (3) Historical Log 3 (4) I/O Change Log (5) I/O Change Log tables: Table : Card Change Flags: #

6 Card Current States: B.5.3: Block Definitions NOTES: Historical Log Programmable Settings: #

7 #

8 NOTE: #

9 NOTE: Register Items Descriptors #

10 NOTE: Log Base Address #

11 NOTE: NOTE: NOTES: #

12 Session Com Port Log Retrieval Header: #

13 #

14 #

15 Log Retrieval Window Block: #

16 NOTES: B.5.4: Log Retrieval B.5.4.: Auto-Increment B.5.4.: Modbus Function Code 0x3 QUERY #

17 NOTES: IMPORTANT! B.5.4.3: Log Retrieval Procedure Scope NOTES: #

18 #

19 NOTES: #

20 B.5.4.4: Log Retrieval Example #

21 Send: Command Receive Data NOTE Send Command Data #

22 Receive NOTE Send Command Receive Data NOTE #

23 Send Command Data Receive NOTES #

24 Send Command Receive Data NOTE: #

25 NOTES NOTES Send Command Data #

26 Receive NOTES NOTES NOTES #

27 NOTES Send Command #

28 Data Receive NOTES B.5.5: Log Record Interpretation System Event Record: Size Data #

29 NOTE #

30 #

31 NOTES Alarm Record Size Data #

32 Interpretation of Alarm Data: #

33 #

34 NOTES #

35 Historical Log Record: Size Data I/O Change Record Size Data #

36 NOTES B.5.6: Examples Log Retrieval Section: send: Meter designation recv: D E 67 5F send: :0 03 C Historical Log status block recv: : E E 00 C E send: : Historical Log PS settings recv: : F 3F F 40 F 4 F 4 F 43 F B 06 0C 06 0D 06 0E send: : "" recv: : send: : Energy PS settings recv: : send: : Connected Port ID recv: : send: :0 03 C Historical Log status block recv: : E E 00 C E #

37 send: :0 03 C3 4F Log Retrieval header recv: : FF FF send: :0 0 C3 4F Engage the log recv: :0 0 C3 4F send: :0 03 C Historical Log status block recv: : E E 00 C E send: :0 0 C Set the retrieval index recv: :0 0 C send: :0 03 C Read first half of window recv: : F 7 0F E F 7 0F E A F 7 0F E send: :0 03 C Read second half of window recv: : B F 7 0F E C F 7 0F E send: :0 03 C Read first half of last window recv: : E F 7 0F E E F 7 0F E E F 7 0F E send: :0 03 C Read second half of last window recv: : E F 7 0F E E F 7 0F E send: :0 06 C3 4F Disengage the log #

38 recv: :0 06 C3 4F Sample Historical Log Record: F 3F F 40 F 4 F 4 F 43 F B 06 0C 06 0D 06 0E These are the These are the These are the Descriptions: Item Values: Type and Size: 3 - # registers 0 - # sectors 0 - interval (SINT byte) Volts A THD Maximum (SINT byte) Volts B THD Maximum (SINT byte) Volts C THD Maximum F 3F F (Float 4 byte) Volts A Minimum F 4 F (Float 4 byte) Volts B Minimum F 43 F (Float 4 byte) Volts C Minimum 06 0B 06 0C (Energy 4 byte) VARhr Negative Phase A 06 0D 06 0E (Energy 4 byte) VARhr Negative Phase B (SINT byte) Volts A st Harmonic Magnitude (SINT byte) Volts A nd Harmonic Magnitude (SINT byte) Volts A 3 rd Harmonic Magnitude (SINT byte) Ib 3 rd Harmonic Magnitude (SINT byte) Ib 4 th Harmonic Magnitude (SINT byte) Ib 5 th Harmonic Magnitude Sample Record F 7 0F E August 3, 0 7:08: % 00 F - 4.7% 7 0F % (indicates the value isn t valid) #

39 E8-00.0% (Fundamental) % % % % % B.6: Important Note Concerning the Shark 00 Meter's Modbus Map B.6.: Hex Representation B.6.: Decimal Representation #

40 B.7: Modbus Register Map (MM- to MM-40) #

41 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Identification Block Fixed Data Section Meter Name ASCII 6 char none F 9-6 Meter Serial Number ASCII 6 char none Meter Type UINT6 bit-mapped st -----vvv t = transducer model (=yes, 0=no), s= submeter model(=yes,0=no), vvv = V-switch: V = standard 00, V = V plus logging, V3 = V plus THD, V4 = V3 plus relays, V5 = V4 plus waveform capture up to 64 samples/cycle and 3 Meg, V6 = V4 plus waveform capture up to 5 samples/cycle and 4 Meg read-only Firmware Version ASCII 4 char none Map Version UINT6 0 to none Meter Configuration UINT6 bit-mapped -----ccc --ffffff ccc = CT denominator ( or 5), ffffff = calibration frequency (50 or 60) ASIC Version UINT none Boot Firmware Version ASCII 4 char none Option Slot Usage UINT6 bit-mapped same as register 0000 (0x70F) Option Slot Usage UINT6 bit-mapped same as register 000 (0xAF7) 00A - 00D 7-30 Meter Type Name ASCII 8 char none 4 00E Reserved Reserved E Reserved Reserved 8 00F Reserved Reserved Integer Readings Block occupies these registers, see below 03-0F Reserved Reserved 94 0F Reserved Reserved 6 Doc# E4970 MM-

42 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Meter Data Section (Note ) Readings Block ( Integer values) read-only Volts A-N UINT6 0 to 9999 volts Volts B-N UINT6 0 to 9999 volts Volts C-N UINT6 0 to 9999 volts Volts A-B UINT6 0 to 9999 volts 0A - 0A Volts B-C UINT6 0 to 9999 volts 0B - 0B Volts C-A UINT6 0 to 9999 volts 0C - 0C Amps A UINT6 0 to 9999 amps 0D - 0D Amps B UINT6 0 to 9999 amps 0E - 0E Amps C UINT6 0 to 9999 amps 0F - 0F Neutral Current UINT to amps.use the settings from Programmable settings for scale Watts, 3-Ph total SINT to watts and decimal point location. (see User Settings Flags) VARs, 3-Ph total SINT to VARs. Per phase power and PF have values VAs, 3-Ph total UINT6 0 to VAs only for WYE hookup and will be Power Factor, 3-Ph total SINT6-000 to +000 none zero for all other hookups Frequency UINT6 0 to 9999 Hz Watts, Phase A SINT M to watts 3. If the reading is 0000 that means that the value is out Watts, Phase B SINT M to watts of range. Please adjust the programmable settings in that case. The display will also show '----' in case of over Watts, Phase C SINT M to watts range VARs, Phase A SINT M to M VARs VARs, Phase B SINT M to M VARs 0A - 0A VARs, Phase C SINT M to M VARs 0B - 0B VAs, Phase A UINT6 0 to VAs 0C - 0C VAs, Phase B UINT6 0 to VAs 0D - 0D VAs, Phase C UINT6 0 to VAs 0E - 0E Power Factor, Phase A SINT6-000 to +000 none 0F - 0F Power Factor, Phase B SINT6-000 to +000 none Power Factor, Phase C SINT6-000 to +000 none Block Size: 7 Primary Readings Block read-only 03E7-03E Volts A-N FLOAT 0 to 9999 M volts 03E9-03EA Volts B-N FLOAT 0 to 9999 M volts 03EB - 03EC Volts C-N FLOAT 0 to 9999 M volts 03ED - 03EE Volts A-B FLOAT 0 to 9999 M volts 03EF - 03F Volts B-C FLOAT 0 to 9999 M volts 03F - 03F 00-0 Volts C-A FLOAT 0 to 9999 M volts 03F3-03F Amps A FLOAT 0 to 9999 M amps 03F5-03F Amps B FLOAT 0 to 9999 M amps 03F7-03F Amps C FLOAT 0 to 9999 M amps 03F9-03FA Watts, 3-Ph total FLOAT M to M watts 03FB - 03FC 00-0 VARs, 3-Ph total FLOAT M to M VARs 03FD - 03FE 0-03 VAs, 3-Ph total FLOAT M to M VAs 03FF Power Factor, 3-Ph total FLOAT -.00 to +.00 none Frequency FLOAT 0 to Hz Neutral Current FLOAT 0 to 9999 M amps Doc# E4970 MM-

43 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Watts, Phase A FLOAT M to M watts Watts, Phase B FLOAT M to M watts A Watts, Phase C FLOAT M to M watts 040B - 040C VARs, Phase A FLOAT M to M VARs 040D - 040E VARs, Phase B FLOAT M to M VARs 040F VARs, Phase C FLOAT M to M VARs Per phase power and PF have values only for WYE hookup and will be VAs, Phase A FLOAT M to M VAs zero for all other hookups VAs, Phase B FLOAT M to M VAs VAs, Phase C FLOAT M to M VAs Power Factor, Phase A FLOAT -.00 to +.00 none A Power Factor, Phase B FLOAT -.00 to +.00 none 04B - 04C Power Factor, Phase C FLOAT -.00 to +.00 none 04D - 04E Symmetrical Component Magnitude, 0 Seq FLOAT 0 to 9999 M volts 04F Symmetrical Component Magnitude, + Seq FLOAT 0 to 9999 M volts Symmetrical Component Magnitude, - Seq FLOAT 0 to 9999 M volts Voltage unbalance per IEC Symmetrical Component Phase, 0 Seq SINT6-800 to degree Symmetrical Component Phase, + Seq SINT6-800 to degree Values apply only to WYE hookup and Symmetrical Component Phase, - Seq SINT6-800 to degree will be zero for all other hookups Unbalance, 0 sequence component UINT6 0 to % Unbalance, -sequence component UINT6 0 to % Current Unbalance UINT6 0 to % Block Size: 66 Primary Energy Block 05DB - 05DC W-hours, Received SINT3 0 to or 0 to read-only Wh per energy format * Wh received & delivered always have opposite signs 05DD - 05DE W-hours, Delivered SINT3 0 to or Wh per energy format * Wh received is positive for "view as load", delivered is 0 to positive for "view as generator" 05DF - 05E W-hours, Net SINT to Wh per energy format * 5 to 8 digits 05E - 05E W-hours, Total SINT3 0 to Wh per energy format 05E3-05E VAR-hours, Positive SINT3 0 to VARh per energy format * decimal point implied, per energy format 05E5-05E VAR-hours, Negative SINT3 0 to VARh per energy format * resolution of digit before decimal point = units, kilo, or 05E7-05E VAR-hours, Net SINT to VARh per energy format mega, per energy format 05E9-05EA VAR-hours, Total SINT3 0 to VARh per energy format * see note 0 05EB - 05EC VA-hours, Total SINT3 0 to VAh per energy format 05ED - 05EE W-hours, Received, Phase A SINT3 0 to or 0 to EF - 05F W-hours, Received, Phase B SINT3 0 to or 0 to F - 05F 5-53 W-hours, Received, Phase C SINT3 0 to or 0 to F3-05F W-hours, Delivered, Phase A SINT3 0 to or 0 to F5-05F W-hours, Delivered, Phase B SINT3 0 to or 0 to F7-05F W-hours, Delivered, Phase C SINT3 0 to or 0 to Wh per energy format Wh per energy format Wh per energy format Wh per energy format Wh per energy format Wh per energy format 05F9-05FA W-hours, Net, Phase A SINT to Wh per energy format 05FB - 05FC W-hours, Net, Phase B SINT to Wh per energy format 05FD - 05FE W-hours, Net, Phase C SINT to Wh per energy format 05FF W-hours, Total, Phase A SINT3 0 to Wh per energy format W-hours, Total, Phase B SINT3 0 to Wh per energy format Doc# E4970 MM-3

44 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg W-hours, Total, Phase C SINT3 0 to Wh per energy format VAR-hours, Positive, Phase A SINT3 0 to VARh per energy format VAR-hours, Positive, Phase B SINT3 0 to VARh per energy format A VAR-hours, Positive, Phase C SINT3 0 to VARh per energy format 060B - 060C VAR-hours, Negative, Phase A SINT3 0 to VARh per energy format 060D - 060E VAR-hours, Negative, Phase B SINT3 0 to VARh per energy format 060F VAR-hours, Negative, Phase C SINT3 0 to VARh per energy format VAR-hours, Net, Phase A SINT to VARh per energy format VAR-hours, Net, Phase B SINT to VARh per energy format VAR-hours, Net, Phase C SINT to VARh per energy format VAR-hours, Total, Phase A SINT3 0 to VARh per energy format A VAR-hours, Total, Phase B SINT3 0 to VARh per energy format 06B - 06C VAR-hours, Total, Phase C SINT3 0 to VARh per energy format 06D - 06E VA-hours, Phase A SINT3 0 to VAh per energy format 06F VA-hours, Phase B SINT3 0 to VAh per energy format VA-hours, Phase C SINT3 0 to VAh per energy format W-hours, Received, rollover count UINT3 0 to 4,94,967,94 These registers count the number of times their W-hours, Delivered, rollover count UINT3 0 to 4,94,967,94 corresponding energy accumulators have wrapped from VAR-hours, Positive, rollover count UINT3 0 to 4,94,967,94 +max to 0. They are reset when energy is reset A VAR-hours, Negative, rollover count UINT3 0 to 4,94,967,94 06B - 06C VA-hours, rollover count UINT3 0 to 4,94,967,94 06D - 06E W-hours in the Interval, Received SINT3 0 to or 0 to Wh per energy format * Wh received & delivered always have opposite signs 06F W-hours in the Interval, Delivered SINT3 0 to or Wh per energy format * Wh received is positive for "view as load", delivered is 0 to positive for "view as generator" VAR-hours in the Interval, Positive SINT3 0 to VARh per energy format VAR-hours in the Interval, Negative SINT3 0 to VARh per energy format * 5 to 8 digits VA-hours in the Interval, Total SINT3 0 to VAh per energy format * decimal point implied, per energy format Wh per energy format W-hours in the Interval, Received, Phase A SINT3 0 to or 0 to A W-hours in the Interval, Received, Phase B SINT3 0 to or 0 to B - 063C W-hours in the Interval, Received, Phase C SINT3 0 to or 0 to D - 063E W-hours in the Interval, Delivered, Phase A SINT3 0 to or 0 to F W-hours in the Interval, Delivered, Phase B SINT3 0 to or 0 to W-hours in the Interval, Delivered, Phase C SINT3 0 to or 0 to * resolution of digit before decimal point = units, kilo, or Wh per energy format mega, per energy format Wh per energy format * see note 0 Wh per energy format Wh per energy format Wh per energy format VAR-hours in the Interval, Positive, Phase A SINT3 0 to VARh per energy format VAR-hours in the Interval, Positive, Phase B SINT3 0 to VARh per energy format VAR-hours in the Interval, Positive, Phase C SINT3 0 to VARh per energy format A 60-6 VAR-hours in the Interval, Negative, Phase A SINT3 0 to VARh per energy format 064B - 064C 6-63 VAR-hours in the Interval, Negative, Phase B SINT3 0 to VARh per energy format 063D - 064E VAR-hours in the Interval, Negative, Phase C SINT3 0 to VARh per energy format 064F VA-hours in the Interval, Phase A SINT3 0 to VAh per energy format VA-hours in the Interval, Phase B SINT3 0 to VAh per energy format VA-hours in the Interval, Phase C SINT3 0 to VAh per energy format Block Size: Doc# E4970 MM-4

45 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Primary Demand Block 07CC - 07CE Demand Interval End TSTAMP Jan000-3Dec099 sec Ex. hh:mm:ss is 03:5:00 and interval size is 5 minutes. Demand interval was 3:00:00 to 3:5:00. Note: is zero until the end of the first interval after meter startup. read-only 3 07CF - 07D Amps A, Average FLOAT 0 to 9999 M amps 07D - 07D Amps B, Average FLOAT 0 to 9999 M amps 07D3-07D Amps C, Average FLOAT 0 to 9999 M amps 07D5-07D Positive Watts, 3-Ph, Average FLOAT M to M watts 07D7-07D Positive VARs, 3-Ph, Average FLOAT M to M VARs 07D9-07DA 00-0 Negative Watts, 3-Ph, Average FLOAT M to M watts 07DB - 07DC 0-03 Negative VARs, 3-Ph, Average FLOAT M to M VARs 07DD - 07DE VAs, 3-Ph, Average FLOAT M to M VAs 07DF - 07E Positive PF, 3-Ph, Average FLOAT -.00 to +.00 none 07E - 07E Negative PF, 3-PF, Average FLOAT -.00 to +.00 none 07E3-07E Neutral Current, Average FLOAT 0 to 9999 M amps 07E5-07E Positive Watts, Phase A, Average FLOAT M to M watts 07E7-07E Positive Watts, Phase B, Average FLOAT M to M watts 07E9-07EA Positive Watts, Phase C, Average FLOAT M to M watts 07EB - 07EC Positive VARs, Phase A, Average FLOAT M to M VARs 07ED - 07EE Positive VARs, Phase B, Average FLOAT M to M VARs 07EF - 07F Positive VARs, Phase C, Average FLOAT M to M VARs 07F - 07F Negative Watts, Phase A, Average FLOAT M to M watts 07F3-07F Negative Watts, Phase B, Average FLOAT M to M watts 07F5-07F Negative Watts, Phase C, Average FLOAT M to M watts 07F7-07F Negative VARs, Phase A, Average FLOAT M to M VARs 07F9-07FA Negative VARs, Phase B, Average FLOAT M to M VARs 07FB - 07FC Negative VARs, Phase C, Average FLOAT M to M VARs 07FD - 07FE VAs, Phase A, Average FLOAT M to M VAs 07FF VAs, Phase B, Average FLOAT M to M VAs VAs, Phase C, Average FLOAT M to M VAs Positive PF, Phase A, Average FLOAT -.00 to +.00 none Positive PF, Phase B, Average FLOAT -.00 to +.00 none Positive PF, Phase C, Average FLOAT -.00 to +.00 none A Negative PF, Phase A, Average FLOAT -.00 to +.00 none 080B - 080C Negative PF, Phase B, Average FLOAT -.00 to +.00 none 080D - 080E Negative PF, Phase C, Average FLOAT -.00 to +.00 none Block Size: 64 Uncompensated Readings Block read-only 0BB7-0BB Watts, 3-Ph total FLOAT M to M watts 0BB9-0BBA VARs, 3-Ph total FLOAT M to M VARs 0BBB - 0BBC VAs, 3-Ph total FLOAT M to M VAs 0BBD - 0BBE Power Factor, 3-Ph total FLOAT -.00 to +.00 none Doc# E4970 MM-5

46 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg 0BBF - 0BC Watts, Phase A FLOAT M to M watts 0BC - 0BC Watts, Phase B FLOAT M to M watts 0BC3-0BC Watts, Phase C FLOAT M to M watts 0BC5-0BC VARs, Phase A FLOAT M to M VARs OBC7-0BC VARs, Phase B FLOAT M to M VARs 0BC9-0BCA VARs, Phase C FLOAT M to M VARs Per phase power and PF have values only for WYE hookup and will be 0BCB - 0BCC VAs, Phase A FLOAT M to M VAs zero for all other hookups. 0BCD - 0BCE VAs, Phase B FLOAT M to M VAs 0BCF - 0BD VAs, Phase C FLOAT M to M VAs 0BD - 0BD Power Factor, Phase A FLOAT -.00 to +.00 none 0BD3-0BD Power Factor, Phase B FLOAT -.00 to +.00 none 0BD5-0BD Power Factor, Phase C FLOAT -.00 to +.00 none 0BD7-0BD W-hours, Received SINT3 0 to or Wh per energy format * Wh received & delivered always have opposite signs 0 to BD9-0BDA W-hours, Delivered SINT3 0 to or Wh per energy format * Wh received is positive for "view as load", delivered is 0 to positive for "view as generator" 0BDB - 0BDC W-hours, Net SINT to Wh per energy format * 5 to 8 digits 0BDD - 0BDE W-hours, Total SINT3 0 to Wh per energy format 0BDF - 0BE VAR-hours, Positive SINT3 0 to VARh per energy format * decimal point implied, per energy format 0BE - 0BE VAR-hours, Negative SINT3 0 to VARh per energy format * resolution of digit before decimal point = units, kilo, or 0BE3-0BE VAR-hours, Net SINT to VARh per energy format mega, per energy format 0BE5-0BE VAR-hours, Total SINT3 0 to VARh per energy format * see note 0 0BE7-0BE VA-hours, Total SINT3 0 to VAh per energy format 0BE9-0BEA W-hours, Received, Phase A SINT3 0 to or 0 to BEB - 0BEC W-hours, Received, Phase B SINT3 0 to or 0 to BED - 0BEE W-hours, Received, Phase C SINT3 0 to or 0 to BEF - 0BF W-hours, Delivered, Phase A SINT3 0 to or 0 to BF - 0BF W-hours, Delivered, Phase B SINT3 0 to or 0 to Wh per energy format Wh per energy format Wh per energy format Wh per energy format Wh per energy format 0BF3-0BF W-hours, Delivered, Phase C SINT3 0 to or Wh per energy format 0 to BF5-0BF W-hours, Net, Phase A SINT to Wh per energy format 0BF7-0BF W-hours, Net, Phase B SINT to Wh per energy format 0BF9-0BFA W-hours, Net, Phase C SINT to Wh per energy format 0BFB - 0BFC W-hours, Total, Phase A SINT3 0 to Wh per energy format 0BFD - 0BFE W-hours, Total, Phase B SINT3 0 to Wh per energy format 0BFF - 0C W-hours, Total, Phase C SINT3 0 to Wh per energy format 0C0-0C VAR-hours, Positive, Phase A SINT3 0 to VARh per energy format 0C03-0C VAR-hours, Positive, Phase B SINT3 0 to VARh per energy format 0C05-0C VAR-hours, Positive, Phase C SINT3 0 to VARh per energy format 0C07-0C VAR-hours, Negative, Phase A SINT3 0 to VARh per energy format 0C09-0C0A VAR-hours, Negative, Phase B SINT3 0 to VARh per energy format 0C0B - 0C0C VAR-hours, Negative, Phase C SINT3 0 to VARh per energy format 0C0D - 0C0E VAR-hours, Net, Phase A SINT to VARh per energy format Doc# E4970 MM-6

47 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg 0C0F - 0C VAR-hours, Net, Phase B SINT to VARh per energy format 0C - 0C VAR-hours, Net, Phase C SINT to VARh per energy format 0C3-0C VAR-hours, Total, Phase A SINT3 0 to VARh per energy format 0C5-0C VAR-hours, Total, Phase B SINT3 0 to VARh per energy format 0C7-0C VAR-hours, Total, Phase C SINT3 0 to VARh per energy format 0C9-0CA VA-hours, Phase A SINT3 0 to VAh per energy format 0CB - 0CC VA-hours, Phase B SINT3 0 to VAh per energy format 0CD - 0CE VA-hours, Phase C SINT3 0 to VAh per energy format Block Size: 04 Phase Angle Block read-only Phase A Current SINT6-800 to degree Phase B Current SINT6-800 to degree Phase C Current SINT6-800 to degree Angle, Volts A-B SINT6-800 to degree Angle, Volts B-C SINT6-800 to degree Angle, Volts C-A SINT6-800 to degree Block Size: 6 Status Block Port ID UINT6 to 4 none Identifies which Shark COM port a master is connected to; for COM, for COM, etc Meter Status UINT6 bit-mapped mmmpch-- tffeeccc mmm = measurement state (0=off, =running normally, =limp mode, 3=warmup, 6&7=boot, others unused) See note 6. pch = NVMEM block OK flags (p=profile, c=calibration, h=header), flag is if OK t - CT PT compensation status. (0=Disabled,=Enabled) ff = flash state (0=initializing, =logging disabled by Vswitch, 3=logging) ee = edit state (0=startup, =normal, =privileged command session, 3=profile update mode) ccc = port enabled for edit(0=none, -4=COM-COM4, 7=front panel) read-only Limits Status UINT6 bit-mapped high byte is setpt, 0=in, =out low byte is setpt, 0=in, =out see notes,, 7 Doc# E4970 MM-7

48 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Time Since Reset UINT3 0 to msec wraps around after max count 98-9A Meter On Time TSTAMP Jan000-3Dec099 sec 3 9B - 9D Current Date and Time TSTAMP Jan000-3Dec099 sec 3 9E - 9E Clock Sync Status UINT6 bit-mapped mmmp pppe s mmmp pppe = configuration per programmable settings (see register 300, 0x753A) s = status: =working properly, 0=not working 9F - 9F Current Day of Week UINT6 to 7 day =Sun, =Mon, etc. Block Size: 3 THD Block (Note 3) 76F - 76F Volts A-N, %THD UINT6 0 to % Volts B-N, %THD UINT6 0 to % Volts C-N, %THD UINT6 0 to % Amps A, %THD UINT6 0 to % Amps B, %THD UINT6 0 to % Amps C, %THD UINT6 0 to % C Phase A Voltage harmonic magnitudes UINT6 0 to % In each group of 40 registers, the first register represents 40 79D - 7C Phase A Voltage harmonic phases SINT6-800 to degree the fundamental frequency or first harmonic, the second 40 7C5-7EC Phase A Current harmonic magnitudes UINT6 0 to % represents the second harmonic, and so on up to the 40 40th register which represents the 40th harmonic. 7ED Phase A Current harmonic phases SINT6-800 to degree C Phase B Voltage harmonic magnitudes UINT6 0 to % Harmonic magnitudes are given as % of the fundamental 40 83D Phase B Voltage harmonic phases SINT6-800 to degree magnitude. Thus the first register in each group of C Phase B Current harmonic magnitudes UINT6 0 to % will typically be A reading of 0000 indicates 40 88D - 8B Phase B Current harmonic phases SINT6-800 to degree invalid. 40 8B5-8DC Phase C Voltage harmonic magnitudes UINT6 0 to % 40 8DD Phase C Voltage harmonic phases SINT6-800 to degree C Phase C Current harmonic magnitudes UINT6 0 to % 40 9D Phase C Current harmonic phases SINT6-800 to degree Wave Scope scale factor for channel Va UINT6 0 to Wave Scope scale factors for channel Ib UINT6 0 to 3767 Convert individual samples to volts or amps: Wave Scope scale factors for channels Vb and Ib A Wave Scope scale factors for channels Vc and Ic read-only UINT6 0 to 3767 V or A = (sample * scale factor) /,000,000 UINT6 0 to 3767 Samples update in conjunction with THD and harmonics; samples not available (all zeroes) if THD not available. 95B - 99A Wave Scope samples for channel Va SINT to B - 9DA Wave Scope samples for channel Ia SINT to DB - AA Wave Scope samples for channel Vb SINT to AB - A5A Wave Scope samples for channel Ib SINT to A5B - A9A Wave Scope samples for channel Vc SINT to A9B - ADA Wave Scope samples for channel Ic SINT to Block Size: 876 Doc# E4970 MM-8

49 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Short term Primary Minimum Block F7 - F Volts A-N, previous Demand interval Short Term Minimum F9 - FA Volts B-N, previous Demand interval Short Term Minimum FB - FC Volts C-N, previous Demand interval Short Term Minimum FD - FE Volts A-B, previous Demand interval Short Term Minimum FF - F Volts B-C, previous Demand interval Short Term Minimum F3 - F Volts C-A, previous Demand interval Short Term Minimum read-only FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts Minimum instantaneous value measured during the FLOAT 0 to 9999 M volts demand interval before the one most recently completed. FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts F33 - F Volts A-N, Short Term Minimum FLOAT 0 to 9999 M volts F35 - F Volts B-N, Short Term Minimum FLOAT 0 to 9999 M volts F37 - F Volts C-N, Short Term Minimum FLOAT 0 to 9999 M volts Minimum instantaneous value measured during the most F39 - F3A Volts A-B, Short Term Minimum FLOAT 0 to 9999 M volts recently completed demand interval. F3B - F3C Volts B-C, Short Term Minimum FLOAT 0 to 9999 M volts F3D - F3E Volts C-A, Short Term Minimum FLOAT 0 to 9999 M volts Block Size: 4 Primary Minimum Block F3F - F Volts A-N, Minimum FLOAT 0 to 9999 M volts F4 - F Volts B-N, Minimum FLOAT 0 to 9999 M volts F43 - F Volts C-N, Minimum FLOAT 0 to 9999 M volts F45 - F Volts A-B, Minimum FLOAT 0 to 9999 M volts F47 - F Volts B-C, Minimum FLOAT 0 to 9999 M volts F49 - F4A Volts C-A, Minimum FLOAT 0 to 9999 M volts F4B - F4C Amps A, Minimum Avg Demand FLOAT 0 to 9999 M amps F4D - F4E Amps B, Minimum Avg Demand FLOAT 0 to 9999 M amps F4F - F Amps C, Minimum Avg Demand FLOAT 0 to 9999 M amps F5 - F Positive Watts, 3-Ph, Minimum Avg Demand FLOAT 0 to M watts F53 - F Positive VARs, 3-Ph, Minimum Avg Demand FLOAT 0 to M VARs F55 - F Negative Watts, 3-Ph, Minimum Avg Demand FLOAT 0 to M watts F57 - F Negative VARs, 3-Ph, Minimum Avg Demand FLOAT 0 to M VARs F59 - F5A VAs, 3-Ph, Minimum Avg Demand FLOAT M to M VAs F5B - F5C Positive Power Factor, 3-Ph, Minimum Avg Demand F5D - F5E Negative Power Factor, 3-Ph, Minimum Avg Demand read-only FLOAT -.00 to +.00 none FLOAT -.00 to +.00 none F5F - F Frequency, Minimum FLOAT 0 to Hz F6 - F Neutral Current, Minimum Avg Demand FLOAT 0 to 9999 M amps F63 - F Positive Watts, Phase A, Minimum Avg Demand FLOAT M to M watts F65 - F Positive Watts, Phase B, Minimum Avg Demand FLOAT M to M watts Doc# E4970 MM-9

50 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Modbus Address F67 - F Positive Watts, Phase C, Minimum Avg Demand FLOAT M to M watts Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg F69 - F6A Positive VARs, Phase A, Minimum Avg Demand FLOAT M to M VARs 0C0F - 0C VAR-hours, Net, Phase B SINT to VARh per energy format F6B - F6C Positive VARs, Phase B, Minimum Avg Demand FLOAT M to M VARs 0C - 0C VAR-hours, Net, Phase C SINT to VARh per energy format F6D - F6E Positive VARs, Phase C, Minimum Avg Demand FLOAT M to M VARs 0C3-0C VAR-hours, Total, Phase A SINT3 0 to VARh per energy format F6F 0C5 - - F70 0C Negative VAR-hours, Watts, Total, Phase Phase A, Minimum B Avg FLOAT SINT to M to M watts VARh per energy format 0C7-0C Demand VAR-hours, Total, Phase C SINT3 0 to VARh per energy format F7 0C9 - - F7 0CA Negative VA-hours, Watts, Phase A B, Minimum Avg FLOAT SINT to M to M watts VAh per energy format 0CB - 0CC Demand VA-hours, Phase B SINT3 0 to VAh per energy format F73 0CD - - F74 0CE Negative Watts, Phase C, Minimum Avg VA-hours, Phase C FLOAT SINT M to M 0 to watts VAh per energy format Demand F75 - F Negative VARs, Phase A, Minimum Avg Demand FLOAT M to M VARs Block Size: 04 Phase F77 Angle - Block F Negative VARs, Phase B, Minimum Avg Demand FLOAT M to M VARs read-only Phase A Current SINT6-800 to degree F F7A Negative Phase VARs, B Current Phase C, Minimum Avg FLOAT SINT M to to M VARs 0. degree Demand Phase C Current SINT6-800 to degree F7B F7C VAs, Phase A, Minimum Avg Demand Angle, Volts A-B FLOAT SINT M to M -800 to +800 VAs 0. degree F7D F7E VAs, Phase B, Minimum Avg Demand Angle, Volts B-C FLOAT SINT M to M -800 to +800 VAs 0. degree F7F F VAs, Phase C, Minimum Avg Demand Angle, Volts C-A FLOAT SINT M to M -800 to +800 VAs 0. degree F8 - F Positive PF, Phase A, Minimum Avg Demand FLOAT -.00 to +.00 none Block Size: 6 F83 - F Positive PF, Phase B, Minimum Avg Demand FLOAT -.00 to +.00 none F85 - F Positive PF, Phase C, Minimum Avg Demand FLOAT -.00 to +.00 none Status Block read-only F87 - F Negative PF, Phase A, Minimum Avg Demand FLOAT -.00 to +.00 none Port ID UINT6 to 4 none Identifies which Shark COM port a master is connected F89 - F8A Negative PF, Phase B, Minimum Avg Demand FLOAT -.00 to +.00 none to; for COM, for COM, etc. F8B F8C Negative PF, Phase C, Minimum Avg Demand Meter Status FLOAT -.00 to +.00 UINT6 bit-mapped none mmmpch-- tffeeccc mmm = measurement state (0=off, =running normally, F8D - F8D Volts A-N, %THD, Minimum UINT6 0 to % =limp mode, 3=warmup, 6&7=boot, others unused) F8E - F8E Volts B-N, %THD, Minimum UINT6 0 to % See note 6. F8F - F8F Volts C-N, %THD, Minimum UINT6 0 to % pch = NVMEM block OK flags (p=profile, c=calibration, F90 - F Amps A, %THD, Minimum UINT6 0 to % h=header), flag is if OK F9 - F Amps B, %THD, Minimum UINT6 0 to % t - CT PT compensation status. (0=Disabled,=Enabled) ff = flash state (0=initializing, =logging disabled by F9 - F Amps C, %THD, Minimum UINT6 0 to % Vswitch, 3=logging) F93 - F Symmetrical Component Magnitude, 0 Seq, FLOAT 0 to 9999 M volts ee = edit state (0=startup, =normal, =privileged Minimum command session, 3=profile update mode) F95 - F Symmetrical Component Magnitude, + Seq, FLOAT 0 to 9999 M volts ccc = port enabled for edit(0=none, -4=COM-COM4, Minimum 7=front panel) F97 - F Symmetrical Component Magnitude, - Seq, FLOAT 0 to 9999 M volts Limits Minimum Status UINT6 bit-mapped high byte is setpt, 0=in, =out F99 - F Symmetrical Component Phase, 0 Seq, SINT6-800 to degree low byte is setpt, 0=in, =out Minimum see notes,, 7 SINT6-800 to degree F9A - F9A Symmetrical Component Phase, + Seq, Minimum F9B - F9B Symmetrical Component Phase, - Seq, Minimum SINT6-800 to degree F9C - F9C Unbalance, 0 sequence, Minimum UINT6 0 to % F9D - F9D Unbalance, -sequence, Minimum UINT6 0 to % F9E - F9E Current Unbalance, Minimum UINT6 0 to % Block Size: 96 Doc# E4970 MM-0

51 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Primary Minimum Block read-only 0CF - 0D Volts A-N, Min TSTAMP Jan000-3Dec099 sec 3 0D - 0D Volts B-N, Min TSTAMP Jan000-3Dec099 sec 3 0D5-0D Volts C-N, Min TSTAMP Jan000-3Dec099 sec 3 0D8-0DA Volts A-B, Min TSTAMP Jan000-3Dec099 sec 3 0DB - 0DD Volts B-C, Min TSTAMP Jan000-3Dec099 sec 3 0DE - 0E Volts C-A, Min TSTAMP Jan000-3Dec099 sec 3 0E - 0E Amps A, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0E4-0E Amps B, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0E7-0E Amps C, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0EA - 0EC Positive Watts, 3-Ph, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0ED - 0EF Positive VARs, 3-Ph, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0F0-0F Negative Watts, 3-Ph, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0F3-0F Negative VARs, 3-Ph, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0F6-0F VAs, 3-Ph, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 0F9-0FB Positive Power Factor, 3-Ph, Min Avg Dmd 0FC - 0FE Negative Power Factor, 3-Ph, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 0FF Frequency, Min TSTAMP Jan000-3Dec099 sec Neutral Current, Min Avg Dmd TSTAMP Jan000-3Dec00 sec Positive Watts, Phase A, Min Avg Dmd 08-0A Positive Watts, Phase B, Min Avg Dmd 0B - 0D Positive Watts, Phase C, Min Avg Dmd 0E Positive VARs, Phase A, Min Avg Dmd Positive VARs, Phase B, Min Avg Dmd Positive VARs, Phase C, Min Avg Dmd Negative Watts, Phase A, Min Avg Dmd A - C Negative Watts, Phase B, Min Avg Dmd D - F Negative Watts, Phase C, Min Avg Dmd Negative VARs, Phase A, Min Avg Dmd Negative VARs, Phase B, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec Negative VARs, Phase C, Min Avg Dmd TSTAMP Jan000-3Dec099 sec B VAs, Phase A, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 C - E VAs, Phase B, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 F VAs, Phase C, Min Avg Dmd TSTAMP Jan000-3Dec099 sec Positive PF, Phase A, Min Avg Dmd TSTAMP Jan000-3Dec099 sec Positive PF, Phase B, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 Doc# E4970 MM-

52 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg 38-3A Positive PF, Phase C, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 3B - 3D Negative PF, Phase A, Min Avg Dmd TSTAMP Jan000-3Dec099 sec 3 3E Negative PF, Phase B, Min Avg Dmd TSTAMP Jan000-3Dec099 sec Negative PF, Phase C, Min Avg Dmd TSTAMP Jan000-3Dec099 sec Volts A-N, %THD, Min TSTAMP Jan000-3Dec099 sec Volts B-N, %THD, Min TSTAMP Jan000-3Dec099 sec 3 4A - 4C Volts C-N, %THD, Min TSTAMP Jan000-3Dec099 sec 3 4D - 4F Amps A, %THD, Min TSTAMP Jan000-3Dec099 sec Amps B, %THD, Min TSTAMP Jan000-3Dec099 sec Amps C, %THD, Min TSTAMP Jan000-3Dec099 sec Symmetrical Comp Magnitude, 0 Seq, Min 59-5B Symmetrical Comp Magnitude, + Seq, Min 5C - 5E Symmetrical Comp Magnitude, - Seq, Min 5F Symmetrical Comp Phase, 0 Seq, Min Symmetrical Comp Phase, + Seq, Min Symmetrical Comp Phase, - Seq, Min TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec Unbalance, 0 Seq, Min TSTAMP Jan000-3Dec099 sec Unbalance, - Seq, Min TSTAMP Jan000-3Dec099 sec Current Unbalance, Min TSTAMP Jan000-3Dec099 sec 3 Block Size: 6 Short term Primary Maximum Block 30F Volts A-N, previous Demand interval Short Term Maximum Volts B-N, previous Demand interval Short Term Maximum Volts C-N, previous Demand interval Short Term Maximum Volts A-B, previous Demand interval Short Term Maximum Volts B-C, previous Demand interval Short Term Maximum FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts 39-3A Volts C-A, previous Demand interval Short Term FLOAT 0 to 9999 M volts Maximum 3B - 3C Volts A-N, Maximum FLOAT 0 to 9999 M volts 3D - 3E Volts B-N, Maximum FLOAT 0 to 9999 M volts 3F Volts C-N, Maximum FLOAT 0 to 9999 M volts Maximum instantaneous value measured during the most Volts A-B, Maximum FLOAT 0 to 9999 M volts recently completed demand interval Volts B-C, Maximum FLOAT 0 to 9999 M volts Volts C-A, Maximum FLOAT 0 to 9999 M volts read-only Maximum instantaneous value measured during the demand interval before the one most recently completed. Block Size: Doc# E4970 MM-

53 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg Primary Maximum Block Volts A-N, Maximum FLOAT 0 to 9999 M volts 39-3A Volts B-N, Maximum FLOAT 0 to 9999 M volts 3B - 3C Volts C-N, Maximum FLOAT 0 to 9999 M volts 3D - 3E Volts A-B, Maximum FLOAT 0 to 9999 M volts 3F Volts B-C, Maximum FLOAT 0 to 9999 M volts Volts C-A, Maximum FLOAT 0 to 9999 M volts Amps A, Maximum Avg Demand FLOAT 0 to 9999 M amps Amps B, Maximum Avg Demand FLOAT 0 to 9999 M amps Amps C, Maximum Avg Demand FLOAT 0 to 9999 M amps A Positive Watts, 3-Ph, Maximum Avg Demand FLOAT 0 to M watts 33B - 33C Positive VARs, 3-Ph, Maximum Avg Demand FLOAT 0 to M VARs 33D - 33E Negative Watts, 3-Ph, Maximum Avg Demand FLOAT 0 to M watts 33F Negative VARs, 3-Ph, Maximum Avg Demand FLOAT 0 to M VARs VAs, 3-Ph, Maximum Avg Demand FLOAT M to M VAs Positive Power Factor, 3-Ph, Maximum Avg Demand Negative Power Factor, 3-Ph, Maximum Avg Demand read-only FLOAT -.00 to +.00 none FLOAT -.00 to +.00 none Frequency, Maximum FLOAT 0 to Hz A Neutral Current, Maximum Avg Demand FLOAT 0 to 9999 M amps 34B - 34C Positive Watts, Phase A, Maximum Avg Demand FLOAT M to M watts 34D - 34E Positive Watts, Phase B, Maximum Avg Demand FLOAT M to M watts 34F Positive Watts, Phase C, Maximum Avg Demand FLOAT M to M watts Positive VARs, Phase A, Maximum Avg Demand FLOAT M to M VARs Positive VARs, Phase B, Maximum Avg Demand FLOAT M to M VARs Positive VARs, Phase C, Maximum Avg Demand FLOAT M to M VARs Negative Watts, Phase A, Maximum Avg Demand A Negative Watts, Phase B, Maximum Avg Demand 35B - 35C Negative Watts, Phase C, Maximum Avg Demand 35D - 35E Negative VARs, Phase A, Maximum Avg Demand 35F Negative VARs, Phase B, Maximum Avg Demand Negative VARs, Phase C, Maximum Avg Demand FLOAT M to M watts FLOAT M to M watts FLOAT M to M watts FLOAT M to M VARs FLOAT M to M VARs FLOAT M to M VARs VAs, Phase A, Maximum Avg Demand FLOAT M to M VAs VAs, Phase B, Maximum Avg Demand FLOAT M to M VAs VAs, Phase C, Maximum Avg Demand FLOAT M to M VAs A Positive PF, Phase A, Maximum Avg Demand FLOAT -.00 to +.00 none Doc# E4970 MM-3

54 B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note ) Format Range (Note 6) Units or Resolution Comments # Reg 36B - 36C Positive PF, Phase B, Maximum Avg Demand FLOAT -.00 to +.00 none 36D - 36E Positive PF, Phase C, Maximum Avg Demand FLOAT -.00 to +.00 none 36F Negative PF, Phase A, Maximum Avg Demand FLOAT -.00 to +.00 none Negative PF, Phase B, Maximum Avg Demand FLOAT -.00 to +.00 none Negative PF, Phase C, Maximum Avg Demand FLOAT -.00 to +.00 none Volts A-N, %THD, Maximum UINT6 0 to % Volts B-N, %THD, Maximum UINT6 0 to % Volts C-N, %THD, Maximum UINT6 0 to % Amps A, %THD, Maximum UINT6 0 to % Amps B, %THD, Maximum UINT6 0 to % 37A - 37A Amps C, %THD, Maximum UINT6 0 to % 37B - 37C Symmetrical Component Magnitude, 0 Seq, Maximum 37D - 37E Symmetrical Component Magnitude, + Seq, Maximum 37F Symmetrical Component Magnitude, - Seq, Maximum Symmetrical Component Phase, 0 Seq, Maximum Symmetrical Component Phase, + Seq, Maximum Symmetrical Component Phase, - Seq, Maximum FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts FLOAT 0 to 9999 M volts SINT6-800 to degree SINT6-800 to degree SINT6-800 to degree Unbalance, 0 Seq, Maximum UINT6 0 to % Unbalance, - Seq, Maximum UINT6 0 to % Current Unbalance, Maximum UINT6 0 to % Block Size: 96 Primary Maximum Block read-only 4B7-4B Volts A-N, Max TSTAMP Jan000-3Dec099 sec 3 4BA - 4BC Volts B-N, Max TSTAMP Jan000-3Dec099 sec 3 4BD - 4BF Volts C-N, Max TSTAMP Jan000-3Dec099 sec 3 4C0-4C Volts A-B, Max TSTAMP Jan000-3Dec099 sec 3 4C3-4C Volts B-C, Max TSTAMP Jan000-3Dec099 sec 3 4C6-4C Volts C-A, Max TSTAMP Jan000-3Dec099 sec 3 4C9-4CB Amps A, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4CC - 4CE Amps B, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4CF - 4D Amps C, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4D - 4D Positive Watts, 3-Ph, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4D5-4D Positive VARs, 3-Ph, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4D8-4DA Negative Watts, 3-Ph, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4DB - 4DD Negative VARs, 3-Ph, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4DE - 4E VAs, 3-Ph, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 4E - 4E Positive Power Factor, 3-Ph, Max Avg Dmd 4E4-4E Negative Power Factor, 3-Ph, Max Avg Dmd TSTAMP Jan000-3Dec099 sec 3 TSTAMP Jan000-3Dec099 sec 3 4E7-4E Frequency, Max TSTAMP Jan000-3Dec099 sec 3 Doc# E4970 MM-4

ATC-300+ Controller Modbus Communications Guide

ATC-300+ Controller Modbus Communications Guide ATC-300+ Controller Modbus Communications Guide CI-AECG-00079-01-E (8/11) 66A7787 revision 1 3. Function Code Descriptions 3.1. Function Code 01 Read ATS Status bits Function code 01 reads the ON / OFF

More information

CIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1

CIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1 Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. Router A Router B Router C Router D Network Next Hop Next Hop Next Hop Next

More information

CIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1

CIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1 Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. NOTE: Router E should only be used for Internet traffic. Router A Router

More information

4. Specifications and Additional Information

4. Specifications and Additional Information 4. Specifications and Additional Information AGX52004-1.0 8B/10B Code This section provides information about the data and control codes for Arria GX devices. Code Notation The 8B/10B data and control

More information

CIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1

CIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1 Version 1 1. (20 Points) Given the class A network address 117.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 4,000 subnets? b. (5 Points) What is

More information

CIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1

CIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1 Version 1 Instructions Write your name on the exam paper. Write your name and version number on the top of the yellow paper. Answer Question 1 on the exam paper. Answer Questions 2-4 on the yellow paper.

More information

CIS-331 Exam 2 Fall 2014 Total of 105 Points. Version 1

CIS-331 Exam 2 Fall 2014 Total of 105 Points. Version 1 Version 1 1. (20 Points) Given the class A network address 119.0.0.0 will be divided into a maximum of 15,900 subnets. a. (5 Points) How many bits will be necessary to address the 15,900 subnets? b. (5

More information

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016 Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation

More information

CIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1

CIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1 Version 1 1. (20 Points) Given the class A network address 121.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 8,100 subnets? b. (5 Points) What is

More information

ECHO Process Instrumentation, Inc. Modbus RS485 Module. Operating Instructions. Version 1.0 June 2010

ECHO Process Instrumentation, Inc. Modbus RS485 Module. Operating Instructions. Version 1.0 June 2010 ECHO Process Instrumentation, Inc. Modbus RS485 Module Operating Instructions Version 1.0 June 2010 ECHO Process Instrumentation, Inc. PO Box 800 Shalimar, FL 32579 PH: 850-609-1300 FX: 850-651-4777 EM:

More information

CIS-331 Final Exam Spring 2018 Total of 120 Points. Version 1

CIS-331 Final Exam Spring 2018 Total of 120 Points. Version 1 Version 1 Instructions 1. Write your name and version number on the top of the yellow paper and the routing tables sheet. 2. Answer Question 2 on the routing tables sheet. 3. Answer Questions 1, 3, 4,

More information

CIS-331 Final Exam Spring 2015 Total of 115 Points. Version 1

CIS-331 Final Exam Spring 2015 Total of 115 Points. Version 1 Version 1 1. (25 Points) Given that a frame is formatted as follows: And given that a datagram is formatted as follows: And given that a TCP segment is formatted as follows: Assuming no options are present

More information

Gateway Ascii Command Protocol

Gateway Ascii Command Protocol Gateway Ascii Command Protocol Table Of Contents Introduction....2 Ascii Commands.....3 Messages Received From The Gateway....3 Button Down Message.....3 Button Up Message....3 Button Maintain Message....4

More information

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603 Data sheet Modbus Module Communication module for MULTICAL 403 and MULTICAL 603 Modbus RTU communication Communication speed up to 115200 bits/s Programmable data, communication speed and parity settings

More information

RISH Master 3440i/3440iDL 0.2S

RISH Master 3440i/3440iDL 0.2S Interface Definition RISH Master 344i/344iDL.2S as per IEC6253-22 DIGITAL MULTIFUNCTION INSTRUMENT Installation & Operating Instructions Section 1. 2. 3. 4. 5. Contents Introduction Communication selection

More information

PowerLogic ION7300 Profibus DP. Serial Communications Protocol October 2006

PowerLogic ION7300 Profibus DP. Serial Communications Protocol October 2006 PowerLogic ION7300 Profibus DP Serial Communications Protocol October 2006 The information contained in this document is believed to be accurate at the time of its publication; however, assumes no responsibility

More information

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603 Data sheet Modbus Module Communication module for MULTICAL 403 and MULTICAL 603 Modbus RTU communication Communication speed up to 115200 bits/s Programmable data, communication speed and parity settings

More information

The cache is 4-way set associative, with 4-byte blocks, and 16 total lines

The cache is 4-way set associative, with 4-byte blocks, and 16 total lines Sample Problem 1 Assume the following memory setup: Virtual addresses are 20 bits wide Physical addresses are 15 bits wide The page size if 1KB (2 10 bytes) The TLB is 2-way set associative, with 8 total

More information

Register Map: Ecoflair Indirect Air Economizer

Register Map: Ecoflair Indirect Air Economizer Register Map: Ecoflair Indirect Air Economizer Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least

More information

MX350 Automatic Transfer Control System Communications Guide

MX350 Automatic Transfer Control System Communications Guide Title page GE Consumer & Industrial Multilin MX350 Automatic Transfer Control System Communications Guide MX350 revision: 1.1x Manual P/N: 1601-9072-A1 GE publication code: GEK-113498 Copyright 2008 GE

More information

C1098 JPEG Module User Manual

C1098 JPEG Module User Manual C1098 JPEG Module User Manual General Description C1098 is VGA camera module performs as a JPEG compressed still camera that can be attached to a wireless or PDA host. Users can send out a snapshot command

More information

Sommario. COMMUNICATION PROTOCOL PR 150 Rev. A 31/01/2018 Pag 1 Multifunction Firmware NEMO 96 EA ModBus

Sommario. COMMUNICATION PROTOCOL PR 150 Rev. A 31/01/2018 Pag 1 Multifunction Firmware NEMO 96 EA ModBus 31/01/2018 Pag 1 Sommario 1. ABSTRACT... 2 1.1. 1.2. Physical level... 2 Data link level... 2 1.3. Application level... 2 2. DATA MESSAGE DESCRIPTION... 3 2.1. Parameters description... 3 2.2. Data format...

More information

APPLESHARE PC UPDATE INTERNATIONAL SUPPORT IN APPLESHARE PC

APPLESHARE PC UPDATE INTERNATIONAL SUPPORT IN APPLESHARE PC APPLESHARE PC UPDATE INTERNATIONAL SUPPORT IN APPLESHARE PC This update to the AppleShare PC User's Guide discusses AppleShare PC support for the use of international character sets, paper sizes, and date

More information

RS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out.

RS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out. RS 232 PINOUTS 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out. 2. A DB9 Female to RJ12 Female Serial/Terminal Modular Adaptor

More information

UNH-IOL MIPI Alliance Test Program

UNH-IOL MIPI Alliance Test Program DSI Receiver Protocol Conformance Test Report UNH-IOL 121 Technology Drive, Suite 2 Durham, NH 03824 +1-603-862-0090 mipilab@iol.unh.edu +1-603-862-0701 Engineer Name engineer@company.com Panel Company

More information

Technical Specification. Third Party Control Protocol. AV Revolution

Technical Specification. Third Party Control Protocol. AV Revolution Technical Specification Third Party Control Protocol AV Revolution Document AM-TS-120308 Version 1.0 Page 1 of 31 DOCUMENT DETAILS Document Title: Technical Specification, Third Party Control Protocol,

More information

WM4-96 (Rev. C04 and following) SERIAL COMMUNICATION PROTOCOL

WM4-96 (Rev. C04 and following) SERIAL COMMUNICATION PROTOCOL Page 1 (Rev. C04 and following) Vers. 1 Rev. 3 February 15 th, 2005 Page 2 Index INDEX...2 1...3 1.1 INTRODUCTION...3 1.2 FUNCTIONS...3 1.3 MEMORY AREA...5 1.4 IDENTIFICATION CODE AND SERIAL NUMBER...6

More information

July Registration of a Cyrillic Character Set. Status of this Memo

July Registration of a Cyrillic Character Set. Status of this Memo Network Working Group Request for Comments: 1489 A. Chernov RELCOM Development Team July 1993 Status of this Memo Registration of a Cyrillic Character Set This memo provides information for the Internet

More information

Modbus Register Map: InRow ACRD60x / ACRC60x

Modbus Register Map: InRow ACRD60x / ACRC60x Modbus Map: InRow ACRD60x / ACRC60x Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least significant

More information

Modbus Register Map for Power Xpert Meter 4000/6000/8000

Modbus Register Map for Power Xpert Meter 4000/6000/8000 Instruction Booklet IB150014EN Effective March 2017 Map for Power Xpert Meter 4000/6000/8000 Contents Description Page Communication.... 2 1. Standard Map.... 7 2. Extended Map... 9 3. THD magnitude registers

More information

TEST DVD-VIDEO/ DVD-ROM For Checking DVD Players, DVD Recorders and DVD Drives TDH-940

TEST DVD-VIDEO/ DVD-ROM For Checking DVD Players, DVD Recorders and DVD Drives TDH-940 TEST DVD-VIDEO/ DVD-ROM For Checking DVD Players, DVD Recorders and DVD Drives TDH-940 Product Introduction. Purpose of use, Features TDH-940 is a Test Disc designed for confirmation of operation of DVD

More information

Hash Constant C Determinants leading to collisionfree

Hash Constant C Determinants leading to collisionfree Hash Constant C Determinants leading to collisionfree (Ernst Erich Schnoor) eschnoor@multi-matrix.de Addendum to article: Core of the CypherMatrix Method http://www.telecypher.net/corecyph.htm#z6 Object

More information

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module , Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION

More information

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page Title page GE Digital Energy D90 Plus Line Distance Protection System Communications guide D90 Plus firmware revision:.9x GE publication code: 60-9070-F (GEK-3469) GE Digital Energy 650 Markland Street

More information

EDR Report Information

EDR Report Information EDR Report File Information Value VIN 5YJXCDE20HF041782 Retrieval Date 2017/06/30 02:16:00 (UTC) Retrieval User Comments Retrieval Program Information EDR Report Information Tesla EDR Reporting Service

More information

USB-ASC232. ASCII RS-232 Controlled USB Keyboard and Mouse Cable. User Manual

USB-ASC232. ASCII RS-232 Controlled USB Keyboard and Mouse Cable. User Manual USB-ASC232 ASCII RS-232 Controlled USB Keyboard and Mouse Cable User Manual Thank you for purchasing the model USB-ASC232 Cable HAGSTROM ELECTRONICS, INC. is pleased that you have selected this product

More information

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls GENERAL MODBUS TABLE ORGANIZATION Starting of the Starting of the Group s Group s System Version (Release) System Version (Build) Group Name (Text) Group Code Group Complexity Group Version 36096 8D00

More information

ZN-DN312XE-M Quick User Guide

ZN-DN312XE-M Quick User Guide ZN-DN312XE-M Quick User Guide This manual provides instructions for quick installation and basic configuration of your IP device. Step1. Connect cables to IP device Connect required cables to the device

More information

PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map

PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map 70022-05-XX PROTOCOL DOCUMENT 04/2007 PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map This document explains the Modbus protocol on the ION6200 meter. The ION6200 meter

More information

6.1 Combinational Circuits. George Boole ( ) Claude Shannon ( )

6.1 Combinational Circuits. George Boole ( ) Claude Shannon ( ) 6. Combinational Circuits George Boole (85 864) Claude Shannon (96 2) Signals and Wires Digital signals Binary (or logical ) values: or, on or off, high or low voltage Wires. Propagate digital signals

More information

GPM-6 MANUAL. GENERAL MODE OPERATING PROCEDURES Volta ge & Current FRONT PANEL & KEY FUNCTIONS. Key Name. Symbol. Descriptions

GPM-6 MANUAL. GENERAL MODE OPERATING PROCEDURES Volta ge & Current FRONT PANEL & KEY FUNCTIONS. Key Name. Symbol. Descriptions G-6 LCD ULTIFUNCTION OWR TR with ULS OUTUT / RS-485 Dlease understand key indicators & functions at the first operation. Key Name Right Key & nter Key Left Key & scapte Key Up Key & Demand Switching Key

More information

DBK24. Isolated Digital Output Chassis. Overview

DBK24. Isolated Digital Output Chassis. Overview DBK24 Isolated Digital Output Chassis Overview 1 Power Requirements 2 Hardware Setup 2 Card Connection 2 Card Configuration 3 DaqBook and DaqBoard Connection 4 DaqBoard/2000 Series Board Connection 5 DaqBook

More information

6.1 Font Types. Font Types

6.1 Font Types. Font Types 6 Font This chapter explains basic features of GP-Pro EX's "Font" and basic ways of placing text with each font. Please start by reading "6.1 Font Types" (page 6-2) and then turn to the corresponding page.

More information

MODBUS TCP Register Mapping For WEM-MX 333mV

MODBUS TCP Register Mapping For WEM-MX 333mV MODBUS TCP Register Mapping For WEM-MX 333mV Data is reported in "Big Endian" and data transmission begins with the high byte. Only Function Code 0x03 (Read Holding Registers) is supported. All Setup is

More information

6. Specifications & Additional Information

6. Specifications & Additional Information 6. Specifications & Additional Information SIIGX52004-3.1 Transceier Blocks Table 6 1 shows the transceier blocks for Stratix II GX and Stratix GX deices and compares their features. Table 6 1. Stratix

More information

First Data EMV Test Card Set. Version 1.30

First Data EMV Test Card Set. Version 1.30 First Data EMV Test Card Set.30 January, 2018 Disclaimer Information provided in this document describes capabilities available at the time of developing this document and information available from industry

More information

CDR File Information. Comments Direct PCM

CDR File Information. Comments Direct PCM IMPORTANT NOTICE: Robert Bosch LLC and the manufacturers whose vehicles are accessible using the CDR System urge end users to use the latest production release of the Crash Data Retrieval system software

More information

First Data EMV Test Card Set. Version 2.00

First Data EMV Test Card Set. Version 2.00 First Data EMV Test Card Set.00 February, 2018 Disclaimer Information provided in this document describes capabilities available at the time of developing this document and information available from industry

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

PSL Power Standards Lab 2020 Challenger Drive Alameda, CA USA TEL FAX

PSL Power Standards Lab 2020 Challenger Drive Alameda, CA USA TEL FAX Reading PQube Meters remotely using Modbus-over-TCP PSL Power Standards Lab 2020 Challenger Drive Alameda, CA 94501 USA TEL ++1-510-522-4400 FAX ++1-510-522-4455 www.powerstandards.com 1 October 2010 A

More information

First Data Dual Interface EMV Test Card Set. Version 1.20

First Data Dual Interface EMV Test Card Set. Version 1.20 First Data Dual Interface EMV Test Card Set August, 2016 Disclaimer Information provided in this document describes capabilities available at the time of developing this document and information available

More information

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications Multilin EPM 6100 Energy and Demand Submeter with Wi-Fi The EPM 6100 is a powerful tool that allows customers to monitor and manage their energy usage within factories, businesses and across campuses.

More information

MM300 Motor Management System Communications Guide

MM300 Motor Management System Communications Guide Title page GE Digital Energy Multilin MM300 Motor Management System Communications Guide MM300 revision: 1.31 Manual P/N: 1601-9025-A4 GE publication code: GEK-113392C Copyright 2008 GE Multilin E83849

More information

Acquirer JCB EMV Test Card Set

Acquirer JCB EMV Test Card Set Acquirer JCB EMV Test Card Set July, 2017 Powered by Disclaimer Information provided in this document describes capabilities available at the time of developing this document and information available

More information

CoPilot EXT. Electro Industries/GaugeTech. Installation & Operation Manual Revision PDA Based Software

CoPilot EXT. Electro Industries/GaugeTech. Installation & Operation Manual Revision PDA Based Software CoPilot EXT PDA Based Software Installation & Operation Manual Revision 1.02 December 3, 2007 Doc #: E156701 V1.02 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel: 516-334-0870

More information

VM7000A PAPERLESS RECORDER COMMUNICATION FUNCTION OPERATION MANUAL

VM7000A PAPERLESS RECORDER COMMUNICATION FUNCTION OPERATION MANUAL VM7000A PAPERLESS RECORDER COMMUNICATION FUNCTION OPERATION MANUAL WXPVM70mnA0002E March, 2014(Rev.5) Copyright 2009-2014, Ohkura Electric Co.,Ltd. All Rights Reserved. To use this equipment safely Thank

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

EM133 Multifunction Meter

EM133 Multifunction Meter EM133 Multifunction Meter Modbus Communications Protocol Reference Guide BG0493 Rev. A6 Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

CURRENT PROTECTION RELAY SMPR-1

CURRENT PROTECTION RELAY SMPR-1 CURRENT PROTECTION RELAY SMPR-1 1.- ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this protocol

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VA-8xl 8-Channel Balanced Stereo Audio Amplifier. P/N: Rev 1

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VA-8xl 8-Channel Balanced Stereo Audio Amplifier. P/N: Rev 1 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VA-8xl 8-Channel Balanced Stereo Audio Amplifier P/N: 2900-300151 Rev 1 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 3

More information

CMSC 313 Lecture 03 Multiple-byte data big-endian vs little-endian sign extension Multiplication and division Floating point formats Character Codes

CMSC 313 Lecture 03 Multiple-byte data big-endian vs little-endian sign extension Multiplication and division Floating point formats Character Codes Multiple-byte data CMSC 313 Lecture 03 big-endian vs little-endian sign extension Multiplication and division Floating point formats Character Codes UMBC, CMSC313, Richard Chang 4-5 Chapter

More information

CIS-331 Final Exam Fall 2015 Total of 120 Points. Version 1

CIS-331 Final Exam Fall 2015 Total of 120 Points. Version 1 Version 1 1. (25 Points) Given that a frame is formatted as follows: And given that a datagram is formatted as follows: And given that a TCP segment is formatted as follows: Assuming no options are present

More information

Systems/DBG Debugger Version 2.20

Systems/DBG Debugger Version 2.20 Systems/DBG Debugger Version 2.20 Copyright c 2018, Dignus, LLC Systems/DBG Debugger Version 2.20 i Copyright c 2018 Dignus LLC, 8378 Six Forks Road Suite 203, Raleigh NC, 27615. World rights reserved.

More information

FP6000. Type ID Units Writable Possible Values. Count. TCP Register

FP6000. Type ID Units Writable Possible Values. Count. TCP Register FP6000 Category System ID 1032 Vendor Name 32 ASCII no-units 1064 Model Name 32 ASCII no-units 1096 Display Name 32 ASCII no-units 1128 Device Type 32 ASCII no-units 1605 Field Replaceable Unit 1 UINT16

More information

CIS-331 Final Exam Spring 2016 Total of 120 Points. Version 1

CIS-331 Final Exam Spring 2016 Total of 120 Points. Version 1 Version 1 1. (25 Points) Given that a frame is formatted as follows: And given that a datagram is formatted as follows: And given that a TCP segment is formatted as follows: Assuming no options are present

More information

Triple DES and AES 192/256 Implementation Notes

Triple DES and AES 192/256 Implementation Notes Triple DES and AES 192/256 Implementation Notes Sample Password-to-Key and KeyChange results of Triple DES and AES 192/256 implementation For InterWorking Labs customers who require detailed information

More information

CMSC 313 COMPUTER ORGANIZATION & ASSEMBLY LANGUAGE PROGRAMMING LECTURE 02, FALL 2012

CMSC 313 COMPUTER ORGANIZATION & ASSEMBLY LANGUAGE PROGRAMMING LECTURE 02, FALL 2012 CMSC 33 COMPUTER ORGANIZATION & ASSEMBLY LANGUAGE PROGRAMMING LECTURE 2, FALL 22 TOPICS TODAY Bits of Memory Data formats for negative numbers Modulo arithmetic & two s complement Floating point formats

More information

COMMUNICATION MODBUS PROTOCOL MF96001 / 021 NEMO 96HD

COMMUNICATION MODBUS PROTOCOL MF96001 / 021 NEMO 96HD COMMUNICATION MODBUS PROTOCOL MF96001 / 021 NEMO 96HD PR106 20/10/2016 Pag. 1/31 Contents 1.0 ABSTRACT... 2 2.0 DATA MESSAGE DESCRIPTION... 3 2.1 Parameters description... 3 2.2 Data format... 4 2.3 Description

More information

First Data DCC Test Card Set. Version 1.30

First Data DCC Test Card Set. Version 1.30 First Data DCC Test Card Set.30 April, 2018 Disclaimer Information provided in this document describes capabilities available at the time of developing this document and information available from industry

More information

One subset of FEAL, called FEAL-NX, is N round FEAL using a 128-bit key without key parity.

One subset of FEAL, called FEAL-NX, is N round FEAL using a 128-bit key without key parity. FEAL-NX SPECIFICATIONS 1 Introduction 1.1 Outline of the FEAL-NX cipher FEAL, the Fast Data Encipherment Algorithm, is a 64-bit block cipher algorithm that enciphers 64-bit plaintexts into 64-bit ciphertexts

More information

10. RS-232C communication

10. RS-232C communication 10. RS-232C communication PB9200(P5XMLA) Connecting the cable (1) Turn off the projector and the computer power supplies. (2) Connect the CONTROL port of the projector with a RS-232C port of the computer

More information

Technical Documentation

Technical Documentation BLR-CM - MODBUS Technical Documentation BLR-CM MODBUS Beluk GmbH Tel.: +49/(0)8861/2332-0 Fax: +49/(0)8861/2332-22 e-mail: blr@beluk.de http://www.beluk.de BLR-CM - MODBUS Page 2 of 20 Document history

More information

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems,

More information

X64. Operator's Guide TECHNICAL. Example of PC signal

X64. Operator's Guide TECHNICAL. Example of PC signal X64 Operator's Guide TECHNICAL Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA VGA (60Hz) 640 x 480

More information

Acquirer JCB Dual Interface EMV Test Card Set

Acquirer JCB Dual Interface EMV Test Card Set Acquirer JCB Dual Interface EMV Test Card Set.00 July, 2018 Powered by Disclaimer Information provided in this document describes capabilities available at the time of developing and delivering this document

More information

CP-X253. User's Manual (detailed) Technical. Example of PC signal. Projector

CP-X253. User's Manual (detailed) Technical. Example of PC signal. Projector Projector CP-X253 User's Manual (detailed) Technical Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA

More information

PM Multifunction meter Cat No. F3N200 - ModbusTable BT EN v1.01.xls

PM Multifunction meter Cat No. F3N200 - ModbusTable BT EN v1.01.xls PM Multifunction meter Cat No. FN200 - ModbusTable BT EN v.0.xls GENERAL MODBUS TABLE ORGANIZATION Starting of the Group s Starting of the Group s System Version (Release) System Version (Build) Group

More information

SERIES PM130EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

SERIES PM130EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE SERIES PM130EH POWERMETERS COMMUNICATIONS ASCII Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

EMS_ _Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx

EMS_ _Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx EMS_ 19 19_Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx GENERAL MODBUS TABLE ORGANIZATION Starting of the Group Starting of the Group System Version System Version Group Name (Text) Group Code Group

More information

Digital Projector X30N/X35N

Digital Projector X30N/X35N Digital Projector X30N/X35N Operator's Guide TECHNICAL Warranty 3M warrants that when the 3M Product is used according to 3M s Intended Use Statement (www.3m.com/meetings), it will perform satisfactorily

More information

HC900 Hybrid Controller Communications User Guide

HC900 Hybrid Controller Communications User Guide HC900 Hybrid Controller Communications User Guide 51-52-25-111 Revision: 6 Industrial Measurement and Control Copyright, Notices, and Trademarks Printed in U.S.A. Copyright 2006 by Honeywell Revision 6

More information

EM24-DIN PFA, PFB & X models

EM24-DIN PFA, PFB & X models EM24-DIN PFA, PFB & X models COMMUNICATION PROTOCOL Version 4 Revision 0 December 03 th, 2012 Index 1.1 Introduction...3 1.2 MODBUS functions...3 1.2.1 Function 03h (Read Holding Registers)...3 1.2.2 Function

More information

Example of PC signal. Projector CP-X2010/CP-X2510/CP-X3010 User's Manual (detailed) Operating Guide Technical

Example of PC signal. Projector CP-X2010/CP-X2510/CP-X3010 User's Manual (detailed) Operating Guide Technical Projector CP-X2010/CP-X2510/CP-X3010 User's Manual (detailed) Operating Guide Technical Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0

More information

Digital Projector X30 Operator's Guide TECHNICAL

Digital Projector X30 Operator's Guide TECHNICAL Digital Projector X30 Operator's Guide TECHNICAL Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA VGA

More information

C192PF8-RPR. Power Factor Manager & Reactive Power Regulator Reference Guide. Modbus. Communications Protocol. BG0348 Rev. A1

C192PF8-RPR. Power Factor Manager & Reactive Power Regulator Reference Guide. Modbus. Communications Protocol. BG0348 Rev. A1 C192PF8-RPR Power Factor Manager & Reactive Power Regulator Reference Guide Modbus Communications Protocol BG0348 Rev. A1 C192PF8-RPR POWER FACTOR MANAGER AND REACTIVE POWER REGULATOR COMMUNICATIONS Modbus

More information

Enhanced Play Fair Cipher

Enhanced Play Fair Cipher P Enhanced Play Fair Cipher 1 1 Naveen KMP P, PDepartment of Information Technology, Velammal Engineering College, Chennai, Tamil Nadu, India. Abstract The theme of this research work is to design and

More information

BLR-CM Modbus. Technical Documentation. Technical Documentation. Rev BLR-CM Modbus. Beluk GmbH Taubenstrasse Schongau Germany

BLR-CM Modbus. Technical Documentation. Technical Documentation. Rev BLR-CM Modbus. Beluk GmbH Taubenstrasse Schongau Germany Beluk GmbH Taubenstrasse 1 86956 Schongau Germany Tel.: +49/(0)8861/2332-0 Fax: +49/(0)8861/2332-22 E-Mail: blr@beluk.de Web: http://www.beluk.de Document history Date Name Revision Comment 08.11.06 ATh

More information

EM300 Series. ET300 Series

EM300 Series. ET300 Series EM300 Series and ET300 Series COMMUNICATION PROTOCOL Version 2 Revision 11 Index 1.1 Introduction... 3 1.2 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read

More information

HC900 Process Controller Communications User Guide

HC900 Process Controller Communications User Guide HC900 Process Controller Communications User Guide 51-52-25-111 Revision: 13 Honeywell Process Solutions Copyright, Notices, and Trademarks Printed in USA Copyright 2017 by Honeywell Revision 13 Warranty/Remedy

More information

Fundamentals of Cryptography

Fundamentals of Cryptography Fundamentals of Cryptography Topics in Quantum-Safe Cryptography June 23, 2016 Part III Data Encryption Standard The Feistel network design m m 0 m 1 f k 1 1 m m 1 2 f k 2 2 DES uses a Feistel network

More information

KNX TinySerial 810. Communication Protocol. WEINZIERL ENGINEERING GmbH

KNX TinySerial 810. Communication Protocol. WEINZIERL ENGINEERING GmbH WEINZIERL ENGINEERING GmbH KNX TinySerial 810 Communication Protocol WEINZIERL ENGINEERING GmbH Bahnhofstr. 6 DE-84558 Tyrlaching GERMAY Tel. +49 8623 / 987 98-03 Fax +49 8623 / 987 98-09 E-Mail: info@weinzierl.de

More information

SERIES PM172EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

SERIES PM172EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE SERIES PM172EH POWERMETERS COMMUNICATIONS Modbus Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

CS 537: Introduction to Operating Systems Fall 2015: Midterm Exam #1

CS 537: Introduction to Operating Systems Fall 2015: Midterm Exam #1 CS 537: Introduction to Operating Systems Fall 2015: Midterm Exam #1 This exam is closed book, closed notes. All cell phones must be turned off. No calculators may be used. You have two hours to complete

More information

TNY Series-Multifunction Panel Meter

TNY Series-Multifunction Panel Meter PROCOM TNY Series-Multifunction Panel Meter Rev.-01 TNY Series-Multifunction Panel Meter 1. Introduction : INDEX 2. Features : 3. Model Selection : 4. Specification : 5. Integer Flow : 6. Auxiliary Supply

More information

EM26-96 COMMUNICATION PROTOCOL. Version 1 Revision 0

EM26-96 COMMUNICATION PROTOCOL. Version 1 Revision 0 EM26-96 COMMUNICATION PROTOCOL Version 1 Revision 0 February 5 th, 2007 Index 1.1 Introduction...3 1.2 MODBUS functions...3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read Input

More information

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES Multilin EPM 6010 BUILDING AUTOMATION POWER METER BACnet /IP Communications and Energy Measurement KEY BENEFITS Rapid integration into BACnet management systems High accuracy multifunction power meter,

More information

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control www.electroind.com Shark 200T Transducer Only Shark 200 Meter/Transducer From Simple to Sophisticated Simple Multifunction Meter: VSwitch Key 1 Historical Datalogging: VSwitch Key 2 Advanced Power Quality

More information

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control www.electroind.com Shark 200T Transducer Only Shark 200 Meter/Transducer From Simple to Sophisticated Simple Multifunction Meter: VSwitch Key 1 Historical Datalogging: VSwitch Key 2 Advanced Power Quality

More information

TLS 1.2 Protocol Execution Transcript

TLS 1.2 Protocol Execution Transcript Appendix C TLS 1.2 Protocol Execution Transcript In Section 2.3, we overviewed a relatively simple protocol execution transcript for SSL 3.0. In this appendix, we do something similar for TLS 1.2. Since

More information

FieldServer Driver FS Heatcraft-Smart Controller II

FieldServer Driver FS Heatcraft-Smart Controller II Description FieldServer Driver FS-8700-100 Heatcraft-Smart Controller II The FieldServer Heatcraft Smart Controller II (HCSCII) driver has the following functionality: 1) Status monitoring of Heatcraft

More information