1 Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB

2 Molded Case Circuit Breakers

3 Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics 06 Protections and Settings 0 Reference Code Motor Operator Automatic Changeover Coding - CTM Accessories Internal Accessories 0 External Accessories Installation Deratings Thermal Dissipation Characteristic Curves - I x t Short Circuit Limitation Characteristic Curves 0 Dimensions Circuit Breaker List - Reference and Code

4 MOLDED CASE CIRCUIT BREAKERS Suitable for industrial, commercial and building applications, the new version of the DWB line of WEG molded case circuit breakers was designed and manufactured according to IEC and IEC 6097-, meeting the operation and protection needs of distribution circuits up to 600 A. The Right Circuit Breaker for our Application The new version of DWB circuit breakers is available with three kinds of protection, that is, circuit breakers with Thermomagnetic protection, Magnetic protection or circuit breakers with Electronic LSI protection specific for each load type. For distribution circuits in general up to 00 A, the circuit breakers with Thermomagnetic element provide enough overload and short circuit protection for both AC and DC applications, allowing the economic and safe assembly of distribution systems. For distribution circuits from 00 A to 600 A, circuit breakers with Electronic LSI protection provide optimization of the protection circuits and higher operation accuracy by means of the following protections: Protection against overload ( L = Long time delay trip) Short-time delay trip for protection against short-circuit ( S = short-time delay), allowing selective action in case of shortcircuit currents Instantaneous short-circuit protection ("I" = Instantaneous) In applications that require the operation and protection of motor circuits, DWB circuit breakers to 00 A have magnetic protection relays especially set for this kind of load, ensuring their correct operation in case of short-circuit currents. The circuit breakers with magnetic protection for motor circuits must be combined with other operation and protection devices, such as overload relays (thermal or electronic). For the operation and protection of generators WEG DWB circuit breakers are also manufactured with protection relays especially set for that kind of load. Protecting and Disconnecting in Frames The new version of the DW line of WEG molded case circuit breakers is available from 6 A to 600 A in only five sizes, according to the maximum rated current of each frame size: DWB60 - maximum rated current of 60 A DWB0 - maximum rated current of 0 A DWB00 - maximum rated current of 00 A Note: ) With Electronic LSI protection. DWB00 and DWB00 ) - maximum rated current of 00 A and 00 A respectively DWB600 ) - maximum rated current of 600 A Molded Case Circuit Breakers

5 WEG DW molded case circuit breakers are manufactured with Quality and high-performance raw materials in order to ensure high efficiency for your application. Frame made of SMC (Sheet Molding Compound): in addition to high mechanical performance, it also presents high dielectric strength and withstands high temperatures Fixed and moving contacts made with special metal alloys to ensure safe operation and long service life Electrolytic copper terminals with surface treatment (silver-coated terminals) ensuring protection against corrosion and excessive heating of the connections Front cover made of polycarbonate (DWB circuit breakers) providing greater safety for the applications The special laser engraving system used on DWB circuit breakers ensures indelibility of the product information and characteristic along its useful life. FLEIBILIT DWB circuit breakers allow flexibility in the use of internal accessories. Interchangeability of accessories among circuit breakers from 60 A to 00 A. DOUBLE PROTECTION In order to provide greater safety for the operator, DW circuit breakers have double insulation between live parts (except for the terminals) and the front parts of the equipment. The internal accessories are completely separate from the power circuit, avoiding any risks of contact with the live parts. HIGH PERFORMANCE DWB molded case circuit breakers can be used in a wide range of applications with great performance under severe overload and short circuit conditions. When installed in motor circuits combined with WEG contactors (CWB and CWM) and WEG smart relays (SRW), they comply with coordination requirements as per IEC Molded Case Circuit Breakers

6 General Characteristics Frame DWB60 DWB0 Standard IEC IEC Number of poles ),, ) ),, ) V ac 690 Rated operational voltage U 7) 690 7) e V dc Insulation voltage U i V Rated impulse withstand voltage U imp kv Utilization category - - A A Reference temperature T C Pollution degree - - Breaking capacity level ka B N L ) B N L ) 0 V~ V~ 0 ) 0 0 I cu V~ 6 0 ) V~ 0 ) Rated ultimate short-circuit breaking capacity - I cu 00 V~ V~ V~ 6 pole V dc poles in series 0 V dc poles in series 00 V dc ka B N L ) B N L ) 0 V~ / 00 V~ Rated service short-circuit breaking capacity - I cs I cs V~ V~ V~ V~ V~ Type of protection and application )) Thermomagnetic for distribution Thermomagnetic for generator 6, 0,,, 0, 0, 6, 70, 0, 90, 0,,,, 60 6, 0,,,0,0, 6, 70, 0, 90, 0,, Fixed thermal and fixed magnetic I n A Not applicable Adjustable thermal and fixed magnetic I n A 0, 0, 6, 0, 0,, 60-0,, 60, 00, 0 0,, 60, 00 Adjustable thermal and adjustable magnetic I n A Not applicable Not applicable Fixed thermal and fixed magnetic I n A, 7,,,, 0, 60 Not applicable Not applicable Adjustable thermal and fixed magnetic I n A Not applicable,, 60, 00, 0 Not applicable Adjustable thermal and adjustable magnetic I n A Not applicable Not applicable Magnetic for motor Fixed magnetic I n A Not applicable,, 0, 0, 6, 0, 9 Not applicable 0,,,, 00 Adjustable magnetic I n A Not applicable Not applicable Electronic (LSI) for distribution and generator A Not applicable Not applicable Switch-disconnector - without thermal and magnetic protection ) I n A, 60 0 Mechanical lifespan - C-O cycle Number of operations/ operations per hour 000 / 000 / Electrical lifespan - C-O cycle (I 690 V) Number of operations/ operations per hour 00 / 00 / Degree of protection Terminals IP IP Accessory cover IP0 IP0 Maximum air relative humidity 9% 9% Connection with cable )) Recommended mm² See the Connection to Terminals section See the Connection to Terminals section Tightening torque Nm 6 ) Recommended cross section mm x mm See the Connection to Terminals section See the Connection to Terminals section Connection with bar (width x thickness) Tightening torque Nm 6 Resistance to vibration (IEC ) a. Hz: amplitude ± mm. a 0 Hz: constant of acceleration 0.7 g a. Hz: amplitude ± mm. a 0 Hz: constant of acceleration 0.7 g Resistance to mechanical shocks (IEC / sine) g for ms g for ms poles: 7 x 7 x poles: x 7 x 6 poles: poles: Dimensions (Width x Depth x Height) mm x mm x mm poles: 7 x 7 x poles: x 7 x 6 7 x 6 x x 7 x 9 poles:. x 7 x poles: x 7 x 6 Net weight kg poles: 0.79 / poles: 0.9 / poles:. poles:. poles:, / poles:. / poles:. poles:.7 Notes: ) poles on the -pole frame, only available with fixed release and breaking capacity level B. ) Only available on -pole frame; not available with protection for generator. ) For I n A: I cu = 0 0 V / V. ) For I n A: I cu = 0 V. ) Recommended torque for the terminal lugs accessory - PC (sold separately). If lug terminal is used directly on the circuit breaker terminal, consider the recommended torque for connection with bar. 6) Product height without terminal cover. 7) For applications above 000 m of altitude, consider the derating indicated in the table of page. ) I n = rated current (fixed thermal release) or maximum setting value (adjustable thermal release). 6 Molded Case Circuit Breakers

7 General Characteristics DWB00 DWB00 DWB00 DWB600 IEC IEC IEC IEC 6097-, ), ),, 690 7) 690 7) 690 7) 7) A A A A N H S H S H ka N V ~ V ~ V ~ V ~ V ~ - 0 V ~ V ~ V dc V dc V dc - N H S H S H ka N V ~ 0 0 V / 00 V ~ 0 V ~ 0 0 V ~ V ~ - 0 V ~ V ~ - Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable 00, 0, 0, 00 0, 00, 00, 60, 00 Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable 00, 0, 0, 00 Not applicable Not applicable 00, 60, 00, 00 Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable,, 0, 0 Not applicable 0, 00 Not applicable Not applicable Not applicable Not applicable 00, 60, 00, 00, , 00 00, / 000 / / / / I n 60 A: 00 / I n =00 A: 00 / 60 I n =00 A: 00 / / 60 IP IP IP IP IP0 IP0 IP0 IP0 9% 9% 9% 9% See the Connection to Terminals section See the Connection to Terminals section See the Connection to Terminals section See the Connection to Terminals section 0 ) 0 ) 0 ) 0 ) See the Connection to Terminals section See the Connection to Terminals section See the Connection to Terminals section See the Connection to Terminals section (M) / 0 (M) a. Hz: amplitude ± mm. a 0 Hz: constant of acceleration 0.7 g a. Hz: amplitude ± mm. a 0 Hz: constant of acceleration 0.7 g a. Hz: amplitude ± mm. a 0 Hz: constant of acceleration 0.7 g a. Hz: amplitude ± mm. a 0 Hz: constant of acceleration 0.7 g g for ms g for ms g for ms g for ms poles: 7 x 99 x 6 poles: x 99 x 6 poles: x 99 x 6 6) poles: x 99 x 6 6) poles: x 6 x 6) poles: 0 x 99 x 6 6) poles: 0 x 99 x 6 6) poles: 0 x 6 x 6) poles:.6 / poles:.6 poles: 7. / poles: 9. poles: 7. / poles: 9. poles: 6. / poles: 9.9 9) Information on thermal dissipation of the circuit breakers available on page. ) Thermal and magnetic operation range available on the Time x Current characteristic curves. ) See the Installation section. "Connection of cables and bars to terminals", "Direct connection of cables by means of round terminal lugs" and "Direct connection of bar to circuit breaker" tables. ) For ambient temperature different from C, consider the deratings of the "Temperature Derating" Table. ) The IWB switch disconnectors use the same platform as DWB circuit breakers and all their accessories. ) It is recommended to use terminal lugs accessories - PC (optional accessory for the circuit breakers, except for DWB60, which is supplied with terminal lugs) or BE straight extension bar. ) DWB60 and DWB0 circuit breakers are available in the four-pole versions with protection on the four poles and P+N version with protection on three poles and disconnection on the fourth pole. DWB00 and DWB00 circuit breakers are available in the four-pole versions with protections on three poles and disconnection on the fourth pole. Molded Case Circuit Breakers 7

8 Protections and Settings Protections In order to meet the different requirements of the different types of load of an electrical circuit, DWB has special versions for each type of load, as shown below. Circuit breakers for distribution: thermal and magnetic protection for electric circuits in general; setting of the short circuit protection from to times the circuit breaker rated current, with tripping curve according to the criteria of IEC standard. Circuit breakers for motors: magnetic protection only. The short circuit tripping curve is set from 7. to times the circuit breaker rated current. Such setting allows starting the motor without premature trip of the protection system. It is necessary to add an overcurrent relay for protection against motor overload. Circuit breakers for generators: the protection against short circuit is set to trip up to five times the circuit breaker rated current, protecting the generator against current surges that may damage its electronics and compromise its regulation. Setting for Circuit Breakers (Motors) DWB60 and DWB0 t Fixed Magnetic Protection The circuit breaker tripping curve is fixed I m l DWB00 and DWB00 t In 0 A. 7. I > x I n I m Adjustable Magnetic Protection 7. to x ln for motors I m l. 7. I > I m. 7. I > I m x I n x I n TEST In 00 A. 7. I > x I n I m Adjustable Magnetic Protection per Phase 7. to x In for motors Molded Case Circuit Breakers

9 Protections and Settings Settings for Circuit Breakers (Distribution and Generators) DWB60 t Fixed Thermal and Fixed Magnetic The circuit breaker tripping curve is fixed I r i DWB60 and DWB0 Cur t Adjustable Thermal and Fixed Magnetic I r The thermal protection curve allows setting the thermal element from 0. to x I n I r 0. i 0.9 xi n I r DWB00 and DWB00 0. Adjustable Thermal Protection The thermal protection curve allows setting the thermal element from 0. to x I n In 00 A xi n I r I> xi n I m Adjustable Thermal Protection to x In for distribution to x In for generators t Adjustable Thermal Protection The thermal protection curve allows setting the thermal element from 0. to x I n I r I m i TEST xi n I r I r 6 I> xi n I m 6 I> xi n I m In 00 A 6 I> xi n I m I m Adjustable Magnetic Protection per Phase to x In for distribution to x In for generators Molded Case Circuit Breakers 9

10 It ON Protections and Settings Settings for Circuit Breakers (Distribution and Generators) DWB00 Electronic LSI Protection Ir.9.9 xin...6 tr 6 at 6 xi r(s) Is 7 x Ir It ON ts... at xi r(s).. Ii x In t I r t r L S I... I t OFF 6 I s t s 70% % I i DWB600-E i Long Protection (L) Short Protection (S) Instantaneous Protection (I) Setting of the rated current and time delay of the overload protection Setting of the current and time delay of the short-circuit protection Setting of the instantaneous tripping current Protections L (Long): overload protection with reverse time-current curve and adjustable time delay S (Short): short circuit protection with time delay, having settings of tripping current and response time, and possibility to choose between reverse time-current curve (I²t ON) or defined time (I²t OFF) I (Instantaneous): short circuit protection with setting of the tripping current, without setting of the response time Indication LEDs Ir.9.9 xin...6 tr 6 at 6 xi r(s) Is 7 x Ir ts... at xi r(s).. Ii x In L S... I t OFF I 6 70% % 70% / %: LED ON when 70% of I n is reached LED flashing when % of I n is reached When closing the circuit breaker after a trip, one of the LEDs of L, S and I indicates which of the settings commanded the las trip, flashing ten times. After such indication, the LEDs remain OFF The electronic protection of the circuit breaker is self-supplied. Thus, the relay will be functional for currents equivalent to 0. x In for three-phase circuit or 0. x In for one phase supplied Molded Case Circuit Breakers

11 Reference Code DWB Line DWB60 DWB0 DWB00 IWB60 IWB0 IWB00 Reference DWB00 DWB00 IWB00 IWB00 Breaking capacity 0 V ac Code ka B 0/ ka N 0 ka L 6 ka H 0 ka S DWB60 B - DF Rated current ) Number of poles ) Type of protection Type of setting Code Fixed thermal and magnetic D Distribution Adjustable thermal, fixed magnetic DF Adjustable thermal and magnetic DA Motor Fixed magnetic MF Adjustable magnetic MA Fixed thermal and magnetic G Generator Adjustable thermal, fixed magnetic GF Adjustable thermal and magnetic GA Distribution generator ) Electronic LSI ET Notes: ) Available for frame DWB00 and DWB600. ) MA release available only. ) Supplied on the -pole frame. Molded Case Circuit Breakers

12 Motor Operator DWB00 circuit breakers Ref. WEG Description 9 Motor operator V dc 7 Motor operator V dc - 60 V dc 79 Motor operator -7 V ac / - V dc 70 Motor operator 0 V ac / 0 V dc DWB00 and DWB00 circuit Ref. WEG Description 79 Motor operator V dc 79 Motor operator V dc - 60 V dc 796 Motor operator -7 V ac / - V dc 79 Motor operator 0 V ac / 0 V dc DWB600 circuit Ref. WEG Description 79 Motor operator V dc 79 Motor operator V dc - 60 V dc 796 Motor operator -7 V ac / - V dc 79 Motor operator 0 V ac / 0 V dc Note: the motor operator is sold separately from the circuit breaker. Automatic Changeover Coding - CTM Smart Code Base Left circuit breaker Right circuit breaker Poles Accessories Base type - Short-circuit capacity Rated current Trip unit Short-circuit capacity Rated current Trip unit Number of poles - Auxiliary contact Alarm contact Shunt trip Undervoltage release Motor operator Example: Smart Code Base Left circuit breaker Right circuit breaker Poles Accessories - - CTM IW H 0 DA P E6 0 C Base type BTIM00 P I cu 0/00 V ac Zero Rated current 0 A Trip un. IW: switch disconnector I cu 0/00 V ac Rated current 6 ka 0 A Trip un. DA: adjustable thermal Auxiliary contact Alarm contact Shunt trip Undervoltage release Motor operator NOC NOC V ac/dc None - 60 V dc Base Left circuit breaker Right circuit breaker Accessories Reference CTM Automatic changeover CTM 00 Frame 00: DWB00 / 00: DWB00 / DWB00 / 600: DWB600-0 Maximum breaking capacity N: ka / S: 0 ka / H: 6 ka / L: 0 ka / 0: No capacity 0 Rated current 00 / 0 / 0 / 00 / 00 / 60 / 00 / 00 / / 600 IW Trip unit / protection DA: Adjustable thermal and magnetic (distribution) GA: Adjustable thermal and magnetic (generator) MA: Adjustable magnetic (motor) ET: Electronic trip unit (DWB00/DWB600) E: Electronic trip unit IW: Switch disconnector H Maximum breaking capacity N: ka / S: 0 ka / H: 6 ka / L: 0 ka / 0: No capacity 0 Rated current 00 / 0 / 0 / 00 / 00 / 60 / 00 / 00 / / 600 DA Trip unit / protection DA: Adjustable thermal and magnetic (distribution) GA: Adjustable thermal and magnetic (generator) MA: Adjustable magnetic (motor) ET: Electronic trip unit (DWB00/DWB600) IWB: Switch disconnector P Number of poles P: poles / P: poles - Auxiliary contact / Alarm contact 0 / E6 Shunt release BD 0: none / E6: V ac - V dc / E7: V ac - V dc E: - V ac - V dc / E: 0-0 V ac - V dc 0 Undervoltage release BS 0: none / C0: V dc / C07: V dc / C: V dc D60: - 7 V ac / D66: 0-0 V ac / D70: 0 - V ac D7: 0-0 V ac C Motor operator C0: V dc / C: - 60 V dc E: -7 V ac / - V dc / E6: 0-0 V ac Molded Case Circuit Breakers

13 Accessories Overview - DWB DWB60 circuit breaker - BS or BD - undervoltage release or shunt release - BC - auxiliary contact block - BFR - DIN rail base - CT - 90 connection extension bars (CP 90 connection extension bars protection cover included) 6 - BE - straight extension bar 7 - PB - phase barrier - PC - terminal lugs (included in the circuit breaker) 9 - MP - escutcheon - BLIM - mechanical interlock - PLW - padlocking device - MR - panel door rotary operating handle - MR - panel door rotary operating handle Note: the IWB60 switch disconnector uses the same accessories as the DWB60 circuit breaker. Molded Case Circuit Breakers

14 Accessories Overview - DWB DWB0 circuit breaker - BS or BD - undervoltage release or shunt release - BC - auxiliary contact block - BFR - DIN rail base - PC - terminal lugs 6 - CT - 90 connection extension bars (CP 90 connection extension bars protection cover included) 7 - BE - straight extension bar - PB - phase barrier 9 - MP - escutcheon - BLIM - mechanical interlock - PLW - padlocking device - MR - panel door rotary operating handle Note: the IWB0 switch disconnector uses the same accessories as the DWB0 circuit breaker. Molded Case Circuit Breakers

15 Accessories Overview - DWB DWB00 circuit breaker - PC - terminal lugs - BE - straight extension bar - PLW - padlocking device - AM - motor operator 6 - BLIM - mechanical interlock 7 - MRI - internal rotary operating handle - MP - escutcheon 9 - MR - panel door rotary operating handle - PB - phase barrier - BS or BD - undervoltage release or shunt release - BC - auxiliary contact block - CT - 90 connection extension bars (CP 90 connection extension bars protection cover included) Note: the IWB00 switch disconnector uses the same accessories as the DWB00 circuit breaker. Molded Case Circuit Breakers

16 Accessories Overview - DWB DWB00 circuit breaker - PC - terminal lugs - CT - 90 connection extension bars (CP 90 connection extension bars protection cover included) - BS or BD - undervoltage release or shunt release - BC/AL - alarm/contact block 6 - BE - straight extension bar 7 - PLW - padlocking device - BLIM - mechanical interlock 9 - MP - escutcheon - AM - motor operator - MRI - internal rotary operating handle - MR - panel door rotary operating handle Note: the IWB00 switch disconnector uses all the accessories of the DWB00 circuit breaker. 6 Molded Case Circuit Breakers

17 Accessories Overview - DWB DWB00 circuit breaker - PC - terminal lugs - CT - 90 connection extension bars (CP 90 connection extension bars protection cover included) - BS or BD - undervoltage release or shunt release - BC/AL - alarm/contact block 6 - BE - straight extension bar 7 - PLW - padlocking device - BLIM - mechanical interlock 9 - MP - escutcheon - AM - motor operator - MRI - internal rotary operating handle - MR - panel door rotary operating handle Note: the IWB00 switch disconnector uses all the accessories of the DWB00 circuit breaker. Molded Case Circuit Breakers 7

18 Accessories Overview - DWB DWB600 circuit breaker - PC - terminal lugs - CT - 90 connection extension bars - BS or BD - undervoltage release or shunt release - BC/AL - alarm/contact block 6 - BE - straight extension bar 7 - PLW - padlocking device - BLIM - mechanical interlock 9 - MP - escutcheon - AM - motor operator - MRI - internal rotary operating handle - MR - panel door rotary operating handle Note: The DWB600 circuit breaker does not have the CP 90 connection extension bars protection cover. Molded Case Circuit Breakers

19 Accessories Overview Description Reference DWB60 DWB0 DWB00 DWB00 DWB00 DWB600 BC-NOC BC-NOC Auxiliary/alarm contact )) BC-NOC AL-NOC BC/AL-NOC BC/AL-NOC /7 V ac - - 0/0 V ac V ac V ac - - V dc - - Undervoltage release BS ) V dc - - V dc V ac / V dc V ac / V dc V ac / V dc / V ac / V dc /0 V ac / V dc V ac / V dc V ac / V dc Shunt trip BD ) 60 V ac / V dc / V ac / V dc 0/0 V ac / V dc Panel door rotary operating handle MR / MR Internal rotary handle MRI - - Din rail base BFR Front mechanical interlock BLIM Padlocking device PLW 90 connection extension bars CT Straight extension bars BE Terminal lugs PC ) Escutcheon MP Motor operator AM - - Phase barrier PB connection extension bars protection cover CP - Notes: ) For combination of BC + AL, always consider the BC/AL block. It is not possible to assemble individual blocks on the circuit breaker. For example: BC + AL. Replace this combination by the BC/AL block. ) DWB circuit breakers are supplied without accessories. The accessories must be purchased separately and assembled at the customer's. ) Included in the product. ) All accessories indicated can also be used on IWB switch disconnectors. Molded Case Circuit Breakers 9

20 Internal Accessories Maximum Combinations of Internal Accessories Model DWB60 ) DWB0 ) DWB00 ) DWB00 / DWB00 ) DWB600 ) P / P P P / P P P / P P P / P P P P Auxiliary contacts BC ) Alarm contact AL ) Model DWB60 ) DWB0 ) DWB00 ) DWB00 / DWB00 ) DWB600 ) P / P P P / P P P / P P P / P P P P Shunt trip BD Undervoltage release BS Notes: ) Sold separately only. It is not sold assembled on the circuit breaker. ) Sold assembled on the circuit breaker only. Not sold separately. ) For combination of BC + AL, always consider the BC/AL block. It is not possible to assemble individual blocks on the circuit breaker. BC + AL, replace this combination by the BC/AL block. Assembly Position of the Internal Accessories BS / BD BS BD BC BC AL BCAL BS BD BC BC AL BCAL BC BC BS BD BC BC BC AL BCAL BCAL BC / AL BS BD BC BC AL BCAL BS BD BC BC AL BCAL DWB60 DWB0 DWB00 DWB00 / DWB00 DWB600 Auxiliary and Alarm Contact Blocks BC - Auxiliary Contact: signals the open and closed position of the main contacts. Reversing type ( NOC). AL - Alarm Contact: signals the thermal or magnetic release of the circuit breaker. Reversing type ( NOC). BC/AL - Auxiliary + Alarm Contact Set: performs the functions above in different contacts in a single set. Configuration of the contact/ alarm block )) DWB60 Ref. WEG ) DWB0 Ref. WEG ) DWB00 Ref. WEG ) DWB00 Ref. WEG ) DWB00 Ref. WEG ) DWB600 Ref. WEG ) Quantity of contacts Auxiliary BC NOC - BC NOC - BC - 06 NOC - AL NOC BC/AL NOC NOC BC/AL NOC NOC Alarm Conduction capacity of the contact blocks Voltage Load type DWB60 / DWB0 / DWB00 / DWB00 / DWB00 DWB600 0 V ac Resistive 6 A A Inductive ) A A V ac Resistive 6 A A Inductive ) A A 0 V dc Resistive 0. A 0. A Inductive ) 0. A 0. A V dc Resistive 0. A 0.6 A Inductive ) 0. A 0.6 A Notes: ) For combinations of BC and AL ( or BCs and BC + AL) always consider the assembled set (BC, BC, BC/AL or BC/AL). It is not possible to assemble individual blocks of BC and AL on the circuit breaker. ) It must not be used to drive motors. ) Sold separately only. It is not sold assembled on the circuit breaker. ) For cable connection, consider maximum cross section of. mm² and torque of 0. Nm. 0 Molded Case Circuit Breakers

21 Internal Accessories Auxiliary and Alarm Contact Blocks Wiring Diagrams of the DWB Circuit Breaker ON OFF TRIP Wiring Diagrams of the DWB600 Circuit Breaker ON OFF TRIP BC AL BC AL Blue Blue Black Red Black Red Blue Blue Black Red Black Red Undervoltage Release and Shunt Trip BS - Undervoltage release: it trips the circuit breaker when its operating voltage is below % of its rated value. That is, when the undervoltage release power supply is U e 0. x U e, the opening of the circuit breaker is ensured. When the voltage is within the range 0. < U e < 0.7, trip may occur, and above 0.7 x U e trip will not occur. Guaranteed trip Possible trip U e BD - Shunt Trip: when the shunt trip is energized by a voltage pulse, the circuit breaker trips. The trip is endured when the shunt trip command voltage is U e > 0.. That is, when its operating range is 0. < U e <. of the rated voltage, the circuit breaker will trip. Guaranteed trip U e Note: to close the circuit breaker, BS must be energized. BS - Undervoltage Release and BD - Shunt Trip Undervoltage release BS Shunt trip BD ) Rated Voltage (U e ) Voltage code DWB60 DWB0 Ref. WEG ) Consumption DWB00 Ref. WEG ) Consumption DWB00 DWB00 Ref. WEG ) -7 V ac D , VA 9 VA 0677 VA 0-0 V ac D VA 9 VA 0677 VA 0- V ac D VA 9 VA 0676 VA 0-0 V ac D VA 96 VA 0676 VA V dc C W 90 W 067 W V dc C W 9 W 0676 W V dc C V ac / V dc E6 0. VA V ac / V dc E7.0 VA V ac / V dc E 6. VA V ac / V dc E. VA V ac / V dc E 66. VA V ac / V dc E VA 67 VA 9 90 VA VA V ac / V dc E7 0. VA VA 9 90 VA VA 60 V ac / V dc E 7 0, VA V ac / V dc E 0. VA 67 6 VA 9 90 VA VA 0-0 V ac / V dc E VA 67 6 VA 9 90 VA VA 0.-. mm² 0-6 AWG 0.-. mm² 0-6 AWG 0.-. mm² 0-6 AWG 0.-. mm² 0-6 AWG Min./max cable Length to strip the wire min./max. -6 mm -7 mm -7 mm -7 mm Tightening torque of the terminal (N.m) Fixing tightening torque (N.m) Snap fit 0. Consumption DWB600 Ref. WEG ) Consumption Notes: ) It has a device to keep the coil de-energized after the trip pulse. ) Sold separately only. It is not sold assembled on the circuit breaker. Wiring Diagrams C BD C BS D D Molded Case Circuit Breakers

22 External Accessories MR - Panel Door Rotary Operating Handle The operator can use the handle to open the panel door in the ON position (thermometry) Total padlocking (circuit breaker + panel door) in the OFF position with up to three padlocks MR Reference handle type Handle color Degree of protection MR Black IP MR Black IP6 MR_E Red IP6 Shaft length (mm) DWB60 Ref. WEG DWB0 Ref. WEG DWB00 Ref. WEG DWB00 DWB00 Ref. WEG DWB600 Ref. WEG MR_E Notes: ) MR and MR allow opening the panel door with the circuit breaker OFF only. The door can be opened with the circuit breaker ON if the operator releases the handle safety lock. ) Sold separately only. It is not sold assembled on the circuit breaker. ) Padlocks... mm may be fit to the handles. MRI - Rotary Operating Handle for Direct Operation of the Circuit Breaker It allows rotary operation of the circuit breaker Padlocking in the OFF position with up to three padlocks Circuit Ref. WEG MRI DWB00 DWB MRI DWB00-00 DWB00 DWB00 76 MRI DWB600 DWB Note: MRI accessory may be used on frames P and P. Mounting BFR - DIN Rail Base It allows fast assembly of the circuit breaker on DIN rail mm Circuit Ref. WEG BFR DWB60 DWB BFR DW B0 DWB0 906 Note: BFR accessory may be used on frames P and P. Lock BLIM - Front Mechanical Interlock Mechanical lock between two circuit breakers, preventing simultaneous closing (ON) It allows the use of to padlocks of... mm Circuit Ref. WEG BLIM DWB60 P DWB60 69 BLIM DWB60 P DWB BLIM DWB0 P DWB0 697 BLIM DWB0 P DWB BLIM DWB00 P DWB BLIM DWB00 P DWB BLIM DWB P DWB00 / DWB00 / DWB600 7 BLIM DWB P DWB00 / DWB00 / DWB600 7 BLIM DWA P DWB BLIM DWA P DWB PLW - Padlocking Device It allows padlocking the circuit breaker in the OFF position. It complies with the requirements of Regulatory Standard - NR It allows the use of to padlocks of... mm Circuit Ref. WEG PL DWB60 P DWB60 7 PL DWB60 P DWB PL DWB0 DWB0 (three poles and four poles) 60 PL DWB00 DWB00 (three poles and four poles) 7 PL DWB DWB00 / DWB00 / DWB600 (three poles and four poles) 7 PL600 DWB600 (three poles and four poles) 60 Molded Case Circuit Breakers

23 External Accessories ) Connection CT - 90 Connection Extension Bars It allows direct connection of bars or cables from the back side of the circuit breaker CP - 90 Connection Extension Bars Protection Cover Accessory only used with 90 connection extension bars to protect terminals and bars It protects the operators and everyone involved in the process against inadvertent contact Circuit Cable / bar Ref. WEG CT DWB60 P ) DWB60 Use the same 7007 CT DWB0 P ) DWB0 cable cross section CT DWB00 P ) DWB00 and dimensions as those of bars DWB00 CT DWB00-00 P ) recommended in DWB00 the technical 77 CT DWB600 P DWB600 characteristics 060 Note: ) CP 90 connection extension bars protection cover included. Circuit Ref. WEG CP protection cover DWB60 P DWB60 90 CP protection cover DWB0 P DWB0 99 CP protection cover DWB00 P DWB00 76 CP protection cover DWB00-00 P DWB00 / DWB00 9 Note: The codes of this table refer to the supply of the CP 90 connection extension bars protection cover only. unit refers to the covering of the phases. No protection cover for poles is available. Accessory available for DWB circuit breakers only. The DWB600 circuit breaker, for example, does not have the 90 connection extension bars protection cover. BE - Straight Extension Bars It extends the terminal length and allows connecting busbars and mounting cables with terminals -piece set PC - Cable Connection Terminal It allows direct connection of cables to the circuit breaker -piece set Round terminal lugs schematic drawing Description Number of cables BE DWB60 P Circuit Cable / bar Ref. WEG DWB BE DWB60 P DWB BE DWB0 P BE DWB0 P DWB0 DWB0 Use the same cable cross section and dimensions as those BE DWB00 P DWB of bars recommended BE DWB00 P DWB00 in the technical 7006 BE DWB00-00 P BE DWB00-00 P DWB00 / DWB00 DWB00 / DWB00 characteristics (installation topic) BE DWB600 P DWB BE DWB600 P DWB DWB60 ) DWB0 DWB00 Round terminal lugs for one cable DWB00 DWB00 DWB600 PC DWB0 P PC DWB00 P PC DWB00-00 P PC DWB600 P Round terminal lugs for one cable (accessory) Round terminal lugs for one cable (accessory) Round terminal lugs for two cables (accessory) Round terminal lugs for four cables (accessory) Maximum cable cross section (mm²) ) Minimum cable cross section (mm²) ) Tightening torque (mm) Cable length to be stripped to use terminal lugs (mm) Reference WEG 6 Supplied with the circuit breaker Finishing ) MP - Escutcheon for Circuit Breaker Operation on Panel Door It provides perfect finishing between the circuit breaker and panel door Circuit Ref. WEG MP DWB60 DWB60 MP DWB0 DWB0 6 MP DWB00 DWB MP DWB DWB00 DWB00 DWB MP DWB600 DWB Notes: ) The accessories are not sold assembled on the DWB circuit breakers. Sold separately only. ) Recommended cross sections for cables with stranding class, insulation of PVC -70 C. ) On DWB60 circuit breakers, the cable connection terminal is included in the factory supply. Not sold as accessory. ) MP accessory can be used on frames P and P. Molded Case Circuit Breakers

24 External Accessories Finishing PB - Phase Barrier The circuit breakers are supplied with two phase barriers. Those barriers must be installed on the line input side. For voltages above 00 Volts, phase barriers must also be installed on the circuit breaker outputs. For such application, the phase barriers must be purchased. They are not supplied with the circuit breaker. Circuit breaker Ref. WEG PB DWB60-0 DWB60 / DWB0 0 PB DWB00 DWB00 76 Note: see table with directions to use the phase barriers on page 0. Motor Operator The motor operator is a mechanical and electrical device whose main characteristics are: It allows remote operation of the circuit breaker Option of manual or automatic operation. Operation from the front of the motor operator Control voltage (motor power supply) in the following levels: -7 V ac / - V dc, 0 V ac / 0 V dc, -60 V dc and V dc Motor operator with direct operation on the circuit breaker handle for DWB00 circuit breakers Motor operator with spring pre-charge for DWB00, DWB00 and DWB600 circuit breakers AM DWB00 AM DWB00 - DWB00 AM DWB600 Molded Case Circuit Breakers

25 External Accessories DWB00 Motor Operator The motor operator of the DWB00 circuit breaker allows choosing between Local and Remote operation on its front part. Assembly of AM00 must be done with the circuit breaker in the OFF position. For MANUAL operation, it is necessary:. Set the slide switch to MANUAL. Insert the operating handle (located on the side bracket) into the front slot and rotate it 0 clockwise;. It must be rotated only 0º clockwise for safely operating the micro switch;. Return the handle to the side bracket. For AUTOMATIC operation, it is necessary:. Set the slide switch to AUTO. In this position it is possible to operate the circuit breaker remotely by sending ON/OFF signals;. Please, do not send ON/OFF signals simultaneously to the motor operator;. If the circuit breaker is equipped with undervoltage release, please charge it before operating the motor operator. Status indication of the Circuit Breaker ON and OFF Front slot / insertion of the operating handle Electrical connection Slide switch Operating handle Wiring Diagram (DWB00) S S S. Nm. mm Ue ON OFF Molded Case Circuit Breakers

26 External Accessories DWB00 / DWB00 / DWB600 Motor Operator The functions of the motor operator, for DWB00, DWB00 and DWB600 circuit breakers, are operated on the front of the product through buttons and through the spring charging handle. The motor operator must be assembled with the spring discharged and the circuit breaker in the ON position. Status indication of the circuit breaker: ON / OFF Handle to charge the spring and open the circuit breaker in manual operation Operating mode: Manual / automatic Spring status: Charged/discharged Close in operation button: manual Electrical connection Wiring Diagram (DWB00-DWB00-DWB600) S S S Ue ON OFF. mm² AWG Technical Data of the Motor Operator Motor operator without spring pre-charge Motor operator with spring pre-charge DWB00 DWB00 Consumption DWB00 Rated Voltage (U e ) Voltage code Consumption DWB600 Consumption - V dc / -7 V ac 0/60 Hz E 79 VA V dc / 0 V ac 0/60 Hz E6 70 VA V dc C 7 W V dc C0 9 W V dc / -7 V ac 0/60 Hz E VA VA 0 V ac / 0 V dc 0/60 Hz E VA 79 0 VA -60 V dc C W 79 0 W V dc C W 79 0 W Voltage range 0. a. U e 0. a. U e 0. a. U e ON time 00ms 0ms 90ms OFF time 00ms 700ms 00ms Trip time (using shunt trip) ms ms 0ms Min./max cable 0.-. mm² 0- AWG 0.-. mm² 0-6 AWG 0.-. mm² 0-6 AWG Length to strip the wire min./max. -7 mm -7 mm -7 mm Tightening torque of the terminal (N.m). Spring terminal Spring terminal Fixing tightening torque (N.m). Notes: The connections with the motor operator AM are done through the connection terminals. Maximum tightening torque of. Nm. The motor operator of the DWB00 circuit breaker is identical to the motor operator of the DWB00, therefore, they can be used without restrictions. The motor operator is sold separately from the circuit breaker. 6 Molded Case Circuit Breakers

27 External Accessories CTM - Automatic Changeover The CTM is a product set, according to IEC 6097-, which works together to form an automatic changeover, ensuring a mechanical interlock with versatility. The system is composed of two DWB molded case circuit breakers, circuit breaker accessory (if necessary), two motor operators and mechanical interlock base (BTIM). Both circuit breakers must be connected in parallel. Characteristics: Greater safety Easy maintenance Very simple assembly of the installation Notes: The CTM set is supplied assembled. The 90 connection extension bars cannot be used as accessory in the CTM set. The circuit breaker accessory table presented on page 9 is valid for the two circuit breakers of the CTM simultaneously, that is, both circuit breakers (left and right side) must have the same accessories (mirrored configuration). AM CODE Motor operator DWB CODE DWB Circuit Breaker and poles DW CIRCUIT BREAKER ACCESSOR CODE BTIM CODE Rear base of mechanical interlock and poles Description Accessory CTM BS Releases ) BD Contact block ) AL BC/AL BC AM DWB00 AM AM DWB00 - AM DWB00 AM DWB600 DWB00 BTIM DWB00 - DWB00 DWB600 Notes: ) Both circuit breakers must have the same release. ) Both circuit breakers must have the same contact or alarm block set. ) Both circuit breakers must have the same frame. ) Both motor operators must be identical. Two terminal strips for connections: electrical connection with circuit breakers, accessories and motor operators. Total closing + opening time between circuit breakers of a CTM CTM Without trip coil With trip coil 00 00ms ms ms 9ms ms ms Opening and closing times of the motor operators Motor operators DWB00 DWB00 / DWB00 DWB600 ON time 00ms 0ms 90ms OFF time 00ms 700ms 00ms Trip time (using shunt trip) ms ms 0ms Molded Case Circuit Breakers 7

28 Installation Installation of the Circuit Breakers Un. DWB60 DWB0 DWB00 DWB00 DWB00 DWB600 mm A: 0 C: 0 D: 0 A: 0 C: 0 D: 0 A: 70 C: 0 D: 0 A: 0 C: 0 D: 0 A: 0 C: 0 D: 0 A: 0 C: 0 D: 0 mm B: B: mm A IEC standard Recommended mounting distances (mm) B D B Recommended distances between circuit breakers for side by side mounting B Recommended distances between circuit breakers for vertical mount ) Non-insulated connection; ) Insulated cable; ) Terminal lugs. A A A 90 Assembly positions Dimensional drawing and mounting P and P B B B AA A DWB60 / DWB0 mm A: 0/ (limiter) B: A: /9 (limiter) B: A: 99 B: A: 0 B: 70 A: 0 B: 70 A: 6 B: 70 mm A: 0/ (limiter) B=B': A: /9 (limiter) B=B': A: 99 B=B': A: 0 B=B': 70 A: 0 B=B': 70 A: 6 B: 70 B'=7 M x 0 x parts M x 60 x parts M x 60 x parts M x 0 x parts M x 60 x 6 parts M x 60 x 6 parts M x 0 x 6 parts DWB00 / DWB00 / DWB00 / DWB600 Dimensional drawing and mounting P B' B' BB B A A DWB60 / DWB0 DWB00 / DWB00 / DWB00 / DWB600 Fixing screw to plate P P - B/N: M x 76 x parts B/N: M x 76 x parts L: Mx76 x part + L: Mx76 x part + Mx x part Mx x part Fixing screw to plate P - B/N: M x 76 x parts B/N: M x 76 x parts M x 0 x 6 parts Parts surpass of the fixing screw in relation to the circuit breaker mm Tightening torque - mounting (Nm) Nm.. 6 Molded Case Circuit Breakers

29 Installation DWB circuit breakers were designed to simplify installation on panels, as they can be supplied from the top or bottom, without compromising the technical characteristics of the components. Cable and Bar Connection to Terminals The connections to circuit breaker terminals must observe the following recommended limit: DWB60 DWB0 DWB00 DWB00 DWB00 DWB600 cable Bare wire cord End terminal Lug terminal Direct to the circuit breaker terminal Through straight extension bar Through round terminal lugs Direct to the circuit breaker terminal ) Through straight extension bar Through round terminal lugs Direct to the circuit breaker terminal ) Through straight extension bar Through round terminal lugs Through straight extension bar Through round terminal lugs - up to 00 A only Through straight extension bar Through round terminal lugs Through straight extension bar Connection with cable cables and cables Bare wire cord End terminal Lug terminal Bare wire cord End terminal Lug terminal Not recommended Not recommended Not recommended Through straight extension bar Through straight extension bar Through straight extension bar Through round terminal lugs Through straight extension bar Through round terminal lugs - up to 00 A only Through straight extension bar Not recommended Not recommended Not recommended Not recommended Not recommended Through straight extension bar Through straight extension bar Through straight extension bar Through straight extension bar Through straight extension bar Through round terminal lugs Through straight extension bar Through round terminal lugs Through straight extension bar More than cables Bare wire cord End terminal Lug terminal Not recommended Not recommended Not recommended Not recommended Not recommended Not recommended Through straight extension bar Through straight extension bar Through straight extension bar Through straight extension bar Through straight extension bar Through straight extension bar Connection with bar Direct to the circuit breaker terminal Direct to the circuit breaker terminal Direct to the circuit breaker terminal Direct to the circuit breaker terminal Direct to the circuit breaker terminal Direct to the circuit breaker terminal Notes: ) The cross section of cables and bars must be observed, as well as the tightening torque informed in the product catalog. ) Pay attention to the lug terminal size, comparing its dimension to the circuit breaker dimension. Some lug terminal models are bigger than the opening and depth of the circuit breaker terminal, and it is not possible to connect them directly to the circuit breaker terminal. Examples of Use Direct connection of the lug terminal to the circuit breaker - cable per terminal: Direct Cable Connection by Round Terminal Lugs DWB60 DWB0 DWB00 DWB00 DWB00 DWB600 Round terminal lugs schematic drawing Number of cables Round terminal lugs for one cable Round terminal lugs for one cable (accessory) Round terminal lugs for one cable (accessory) Round terminal lugs for two cables (accessory) Round terminal lugs for two cables (accessory) Round terminal lugs for four cables (accessory) Maximum cable cross section (mm²) ) Minimum cable cross section (mm²) ) Cable length to be stripped to use terminal lugs (mm) 6 Tightening torque (N.m) Note: recommended cross sections for cables with stranding class, insulation of PVC - 70 C, according to the NM NBR 0 standard (IEC 60). Direct Connection to the Circuit Breaker Bar Quantity DWB60 DWB0 DWB00 DWB00 DWB00 DWB600 Maximum width (mm) Maximum thickness (mm) Tightening torque (N.m) (M) / 0 (M) Molded Case Circuit Breakers 9

30 L Installation Use of Phase Barrier and Terminal Cover The connections to the circuit breaker terminals must observe the following recommended limit: L Insulating plate )) Phase barriers or terminal covers ) H H Insulating plate )) Phase barriers or terminal covers ) L circuit breaker width H length of the terminal cover or phase barrier Connection with cable Connection with insulated bar Bare wire/cord end terminal Lug terminal Connection with 90 connection extension bars ) Ue <00 V Ue 00 V Input Output Input Output Mandatory use of phase barrier ) or terminal cover Mandatory use of phase barrier ) or terminal cover Mandatory use of phase barrier ) or terminal cover Mandatory use of protection cover Optional use of phase barrier ) or terminal cover Optional use of phase barrier ) or terminal cover Optional use of phase barrier ) or terminal cover Mandatory use of protection cover Mandatory use of phase barrier ) or terminal cover Mandatory use of phase barrier ) or terminal cover Mandatory use of phase barrier ) or terminal cover Mandatory use of protection cover Mandatory use of phase barrier ) or terminal cover Mandatory use of phase barrier ) or terminal cover Mandatory use of phase barrier ) or terminal cover Mandatory use of protection cover Insulating plate ))) Optional Optional Mandatory Mandatory Notes: ) phase barriers are supplied on DWB60, DWB0 and DWB00 circuit breakers. When two more barriers are necessary, those parts are sold as accessory. ) Protection cover supplied with the 90 connection extension bars DWB circuit breaker. For DWB600, use the terminal cover included in the product. ) Not supplied with the molded case circuit breakers. It must be produced by the user. ) Minimum characteristics requirements of the material to be used as insulating plate: Dielectric strength kv/mm. Material not propagating flame. Recommended material: phenolite, polycarbonate. ) Installation according to the figure above. 0 Molded Case Circuit Breakers

31 Deratings Altitude Derating Application of circuit breakers in altitude Altitude (m) Derating for the rated current I n Maximum rated operating voltage U e (V) Temperature Derating C C 0 C C 0 C C 0 C C 0 C C 60 C DWB DWB DWB DWB DWB DWB Notes: The recommended temperature refers to the place where the circuit breaker is installed. Apply the recommended derating to the rated current of the relevant circuit breaker. Molded Case Circuit Breakers

32 Thermal Dissipation Circuit Protection DWB60 DWB60L DWB0 DWB0L DWB00 DWB00 DWB00 DWB600 I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) 7 6 I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) 600 Thermal dissipation (W/pole) 96 Motor Protection DWB60 DWB60L DWB0 DWB0L DWB00 DWB00 I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole). 7. I n (A) Thermal dissipation (W/pole) I n (A) 0 0 Thermal dissipation (W/pole) 0 9 I n (A) 0 00 Thermal dissipation (W/pole) Generator Protection DWB60 DWB0 DWB00 DWB00 I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) Disconnectors IWB60 IWB0 IWB00 IWB00 IWB00 I n (A) 60 Thermal dissipation (W/pole) I n (A) 0 Thermal dissipation (W/pole) 0 I n (A) 00 Thermal dissipation (W/pole) I n (A) Thermal dissipation (W/pole) 0 0 I n (A) 00 Thermal dissipation (W/pole) 6 Molded Case Circuit Breakers

33 Characteristic Curves - I x t DWB60_D (Distribution) t (s) t (s) 0. 0, 0. 0, 6060A: 6. 6, x xinln A: A: xinx ln 0. 0, A: 7. 7, x xin ln 0A: A: xin x ln A:, xin 6A:,7 xln 0.0 0,0. x ln 6 A:.7 x ln to a A:, x xinln 0.0 0, ,0., x xin DWB60_G (Generator) t (s) t (s) 0. 0, A:. x ln 0. 0, 7 to 60 A: x ln 0. 0, 0.0 0, , ,0., x In x In DWB60_M (Motor) t (s) t (s) 0. 0, 0. 0, 0. 0, 0.0 0,0 x ln 0.0 0, ,0., x xin Molded Case Circuit Breakers

34 Characteristic Curves - I x t DWB0_D (Distribution) t(s) t (s) , 0. 0, x ln 0. 0, 0.0 0, , ,0., x xin DWB0_G (Generator) t (s) t (s) 0. 0, 0. 0, x ln 0. 0, 0.0 0, , ,0., x In DWB0_M (Motor) t (s) t(s) , 0. 0, 0. 0, 0.0 0,0 x ln 0.0 0, ,0., x xin Molded Case Circuit Breakers

35 Characteristic Curves - I x t DWB00_D (Distribution) t (s) t (s) 0 DWB00_G (Generator) t(s) t (s) , 0. 0, 0. 0, 0.0 0,0 Min. magn. adj. x In Max. magn. adj. x In 0. 0, 0. 0, 0. 0, 0.0 0,0 Max. magn. adj. x In Min. magn. adj.. x In 0.0 0, ,0., x xin 0.0 0, ,0., x xin DWB00_M (Motor) t (s) t(s) 0. 0, 0. 0, 0. 0, 0.0 0,0 Min. magn. adj. 7. x In Max. magn. adj. x In 0.0 0, ,0, x xin Molded Case Circuit Breakers

36 Characteristic Curves - I x t DWB00 (Distribution) DWB00 (Generator) t(s) t (s) 0. 0, 0. 0, 00 A: Min. magn. adj. x In Up to 60 A: Min. magn. adj. x In 00 A: Max. magn.. adj. x In Up to 60 A: Max. magn. adj. x In t (s) t(s) 0. 0, 0. 0, Max. magn. adj. x In 0. 0, 0.0 0,0 0. 0, 0.0 0,0 Min. magn. adj.. x In 0.0 0, ,0., x xin 0.0 0, ,0., x In DWB00 (Motor) t (s) t(s) , 0. 0, 0. 0, 0.0 0, ,0 Min. magn. adj. 7. x In Max. magn. adj. x In 0.0 0,0., x In 6 Molded Case Circuit Breakers

37 Characteristic Curves - I x t DWB00 - Overload Protection (L and S) DWB00 - Short Circuit Protection (I - Instantaneous) (h) Ir Ir = 0...xIn (min) 6.6 i²t i t ON i²t i t OFF t [s] Tolerance ± % Tolerance ±% tr tr =.6...s at 6xIr at 6xlr ts ts = = s at at xlr xlr Is =...xir...xlr ,0 x Ir (r.m.s) Note: The DWB00 can be used for the protection of both electric circuits and generators. Thermomagnetic protection...xin= Ii x In (r.m.s) Molded Case Circuit Breakers 7

38 Characteristic Curves - I x t DWB600 - Overload Protection (L and S) DWB600 - Short Circuit Protection (I - Instantaneous) (h) Ir Ir = 0...xIn (min) 6.6 i²t i t ON i²t i t OFF t [s] Tolerance ± % Tolerance ±% tr tr =.6...s at 6xIr at 6xlr ts ts = = s at at xlr xlr Is =...xir...xlr ,0 x Ir (r.m.s) Instantaneous protection...xin= Ii x In (r.m.s) Note: The DWB600-ET can be used for the protection of both electric circuits and generators. Molded Case Circuit Breakers

39 Characteristic Curves - I x t 0/ V ac DWB60 B/N DWB60 L Ip (kâ) (ka) B N Ip (ka) Ip (ka) L Is (ka) Is Is (ka) DWB0 B/N 00 DWB0 L N 0 L Ip (kâ) (ka) 0 B Ip (kâ) Ip (ka) Is (ka) Is Is (ka) (ka) Molded Case Circuit Breakers 9

40 Short Circuit Limiting Characteristic Curve 0/ V ac DWB00 DWB N H N S H Ip (ka) Ip (kâ) 0 Ip (ka) (kâ) Is (ka) Is (ka) DWB00 00 DWB N S H S H 0 0 Ip (ka) (kâ) 0 Ip (kâ) (ka) Is (ka) Is (ka) 0 Molded Case Circuit Breakers

41 Molded Case Circuit Breakers 0,9 0,9,, ,69,,77 6,00 7,066 0,9 70, 7 77,,07 9,,69 66,0,6 0,6,7 0,,909 7,0,77,,7,,,,60 66,9 07, ,9 0,9,0,,7 77,9,07 6,6 9,,7, Circuit Breakers Dimensions DWB60 B/N / IWB60 DWB0 B/N / IWB0 DWB60 L DWB0 L ,9 7, 6,7 6, 6,,77,6 6,6,7,7,,9 6,,69 7,,9 7,07,6 0,6 6,69 6,69 0,76 9, 7,

42 Dimensions Circuit Breakers DWB00 / IWB00 0,97.7,7,9 6. 6, 0,,,9,..,,,06, 7.,7 7,,7,,0,6,7,6 69 6,6 69,7,7 DWB00 / IWB00,7 99.,90 99, 9.9,7 9,9.,0,.,070, B 0,9.7,7, 9,7.,,.,,9 0,7,0.,,69 9 6, , A,76 70,76 70, ,7, 7.7 7,7,.6,6, , DWB00 / IWB00 B.7 0,9,7, 9,7.,,.,,9 0,7 A,76, DWB600.6,7,6 C 9 0,7 9,90 0,6 9,0 9,0,0 9,,6,9,0 0,9.7, x Ø9 x 0, 9, ,9 0,., 0, x Ø9 x 9 0,9, DETALHE DETAIL A TOA ESCALA SCALE : : 0,0.7,7 DETALHE DETAIL B TOB ESCALA SCALE : : 0,6., 0,9.7,7 x Ø9 x 0, 9, ,9 0,.,.,0, 9,69 9 6, , 0, x Ø9 x 9 0,9, DETALHE DETAIL A TOA ESCALA : SCALE : 0,0.7,7 DETALHE DETAIL B TOB ESCALA SCALE : : 0,6.,, ,7, 7.7 7,7,.6,6, ,, , 0 0 M x M 0,9,60 0,97.7,7,7,7 0,6., M x M, 09 09,7,, 70 70,76 70,76 70,76 6,66 9 6, 6 0 7,9 0 DETAIL DETALHE C TO C SCALE ESCALA :. Molded Case Circuit Breakers

43 Dimensions Accessories MP - Escutcheons MP DWB60 MP DWB0 MP DWB00 9 MP DWB00 / DWB00 / DWB600 9 BE - Straight Extension Bars Frame 60 P + BE DWB60 P Frame 0 P + BE DWB0 P Frame 00 P + BE DWB00 P ,6 Ø.6 7 6,6 Ø.6 7 0,6 Ø.6 7,6 Ø Frame DWB00-00 P + BE DWB00-00 Frame 600 P + BE DWB ,79 0 0, , , 09 0,79, 0 0.,,9 7. 7,,7,7, (600 A) 9 6 (up(600 to A) A) (Até A) Molded Case Circuit Breakers

44 Accessories MR DWB60 MR DWB60 MR DWB60 MR - Panel Door Operating Handle Frame 60 P/P + MR DWB60 MRB DWB60 Dimensions MRB DWB60 Frame 60 P/P + MR DWB60 MR DWB60 Frame 0 P/P + MR DWB0 MR DWB0 MR DWB MRB DWB60 MRB DWB60 MR DWB60 MR DWB MR...0 DWB MR DWB Furação da porta do Painel Panel Door Cutout Furação da porta do Painel Furação da porta do Painel Furação da porta do Painel 7 6, Furação da porta do. Painel Furação da porta do Painel Panel Furação Door da Cutout porta do Painel Furação Panel Door da porta Cutout do Painel Furação da porta do Painel Furação da porta do Painel Ø 0 Ø 0 Furação da porta do Painel Furação da porta do Painel Ø Ø Ø Ø Ø Ø Ø,, Ø Ø,, Ø Ø Ø, Furação Furação da da porta porta do Painel do Painel,,, Ø Ø Ø Ø Ø Ø Ø 0 Ø 6 0,. Ø Ø Ø,, 0 Furação da porta do Painel Furação da porta do Painel Ø, Ø, Ø 0 Ø Ø Ø Ø Ø 0 Ø Ø., Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø,, Ø, Ø Ø MR DWA600 Ø... Ø,,, MR DWA00 MR DWA00 MR DWA MR D Ø... Ø MR DWA600 MR DWA60 0 Ø... Ø MR D 0 0 Ø Ø Ø Ø. Ø,, Ø Ø,. Ø...Ø Ø... Ø Ø, Ø... Ø 6 0 Ø Ø Ø Molded Case Circuit Breakers

45 6 7 Dimensions Accessories MR - Panel Door Operating Handle Furação da porta do Painel MR DWA00 Furação da da porta porta do do Painel Painel MR MR DWA00 o Painel da porta do Painel Frame 00 P/P + MR MR DWB00 DWA00MR DWA00, ,,,, 0 0, Ø, Painel rta do do Painel Painel l Ø, Ø, Ø, Ø... Ø Ø 99.6, 6 Ø Ø... Ø 0 Ø, Ø 7 (P),, Ø... Ø Ø... Ø Ø... Ø Panel Door Cutout Furação da porta do Painel 6 Furação da da porta porta do do Painel Painel Furação da 6porta Furação do Painel da porta do Painel Ø Ø 0 Ø Ø Ø 0 Ø Ø Ø Ø 0 Ø Ø Ø Ø Ø 0 0 Ø Ø Ø Ø Ø Painel rta do do Painel Painel l MR DWA00 Furação da porta do Painel Frame DWB00-00 MR DWA00 + MR MR DWA00 MR DWA00 DWB00-00 Furação da porta Furação Panel Furação do Painel da Door da porta do Cutout da porta porta do do Painel Painel Painel,7, [,..., ] ,0 6, Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø ØØ Ø MR DWA600 MR MR DWA600 Frame 600 MR P/P DWA600 + MR DWA600 DWB Panel Door Cutout 6 Furação da porta do Painel 6 6 Furação da da porta porta do do Painel Painel Furação da porta Furação do Painel da porta do Painel l Painel Ø Ø 6 Ø Ø Ø 6 Ø Ø 6 Ø Ø Ø Ø 6 Ø Ø Ø ØØ Ø Ø Molded Case Circuit Breakers

46 6 7, 7 Dimensions Accessories MRI - Internal Rotary Handle Frame 00 P + MRI DWB00 Frame P + MRI DWB , 6,0 Frame 600 P + MRI DWB , ,7 BLIM - Mechanical Interlock Frame 60 P + BLIM DWB60 P Frame 0 P + BLIM DWB0 P Frame 00 P + BLIM DWB00 P Frame 00 P + BLIM DWB00 / DWB00 Frame 600 P + BLIM DWB Molded Case Circuit Breakers

47 99,6 7 7, Dimensions Accessories PLW - Padlocking Device Frame 60 P + PLW DWB60 P Frame 0 P + PLW DWB0 Frame 00 P + PLW DWB Frame PLW (P) Frame PLW600 0 (P) 09 AM - Motor Operator AM DWB00 / DWB00 / DWB600 9, 9. AM DWB ,, ,6,7,7,96., Molded Case Circuit Breakers 7

48 Dimensions Accessories CTM - Automatic Changeover CTM 00-P ø 7.6 ø7. ø..7 AM DWB00 AM DWB00 9 CTM 00-P CTM 00-P / CTM 00-P 0,6 ø9. 9,. 6, ø 6. ø7. ø. 7. AM DWB00 AM DWB ,6, 9 0,7 ø 0,9 ø.7 9, 9.,6.6 Molded Case Circuit Breakers

49 Dimensions Accessories CTM - Automatic Changeover CTM 00-P / CTM 00-P 6 0,6 ø9. 9, ø 0,7 6 6, ,9 ø 6, 6. 0,6 0.6 CTM 600-P 9 0,6 ø9. 9, 0,7 ø 0,6., 9, , 7.9,9 0,9 ø ,7 7, 7. CTM 600-P 6 6 0,6 ø9. 9, 0,7 ø 6. 6, 7 0,9 ø, ,7 7, 7. Molded Case Circuit Breakers 9

50 ,6 7. 7, 0, 6, ,7,06.,,7.,,9 0. 0,,0.6,6 6 Dimensions Accessories Protection Cover + DWB60 + CT DWB60 Protection Cover + DWB0 + CT DWB0 Protection Cover + DWB00 + CT DWB00,, 9, 7, 99, 6 M,, 0,97.7,7,9 6 0,79 0 x M,7,,7,,0 6,6 9. 9,, 6 0,, 0,,,9.,,6 67,0 0,9 0,9 0,6 6,,,7,9 0 0,9 0,9 0,9, ,9,0 7,,66 67,7,6 9, 0,,,, 0,9 x M,7,,60,77 66,, ,9 7,6 9. 9, 0, 6,,76 70,9 7. 7, 0,9.,,7 6. 6,,,,0., 0,7,, 6,7 67, 0,,, 0 0,9,,9 6. 6,,6, ,, 9.9 9,9,0.,,07., Protection Cover + DWB00 / DWB00 + CT DWB00 / DWB00, 6. 6, 0,, , , x M....,7.6,6,06, ,,0., x M 0,9, ,7 0 0,7, ,6 x M 0,9 67 ø , ,,9 7 7, , 9. 6.,6,69.6,6 6. 6, 70,07 7,7, 6. 6,., x M. ø. 6 x M, , ,06 0 0,9,. 97.7, 97,7, 7.7 7,7,.6,6, , 0 Molded Case Circuit Breakers

51 Circuit Breaker List - Reference and Code Distribution Fixed Thermal and Fixed Magnetic Release Reference DWB60 I n I m B ( ka) N (0 ka) ) L (0 ka) I cu (0 V) poles poles poles (P+N) poles (P) poles poles (P+N) poles (P) poles Adjustable Thermal and Fixed Magnetic Release Reference I I B ( ka) N (0 ka) L (0 ka) I cu (0 V) n m poles poles poles (P+N) poles (P) poles poles (P+N) poles (P) poles DWB DWB Adjustable Thermal and Adjustable Magnetic Release Reference I I N ( ka) H (6 ka) I cu (0 V) n m poles poles poles (P+N) poles poles (P+N) DWB Reference I I S (0 ka) H (6 ka) I cu (0 V) n m - poles poles (P+N) poles poles (P+N) DWB Electronic LSI Release Reference I I N ( ka) S (0 ka) H (6 ka) I cu (0 V) n m poles poles poles (P+N) poles poles (P+N) poles poles (P+N) DWB DWB Note: ) For DWB600 circuit breakers with In from 6 to A, the values of Icu are 0 0 V. Molded Case Circuit Breakers

52 Circuit Breaker List - Reference and Code Generator Fixed Thermal and Fixed Magnetic Release Reference I n I m B ( ka) I cu (0 V) poles DWB Adjustable Thermal and Fixed Magnetic Release Reference I n I m B ( ka) I cu (0 V) poles DWB Adjustable Thermal and Adjustable Magnetic Release Reference I n I m N ( ka) I cu (0 V) poles poles (P+N) DWB DWB Disparador Electrónico - LSI Reference I n I m S (0 ka) I cu (0 V) poles poles (P+N) DWB Molded Case Circuit Breakers

53 Circuit Breaker List - Reference and Code Motor Fixed Magnetic Release Reference I I N (0 ka) L (0 ka) I cu (0 V) n m poles poles DWB Reference I n I m N ( ka) L (0 ka) DWB0 Adjustable Magnetic Release Reference I n I m H (6 ka) I cu (0 V) poles DWB DWB Switch Disconnector Reference I n poles poles 0 - IWB IWB IWB IWB IWB Molded Case Circuit Breakers

54 Global presence is essential, as much as understanding your needs. Global Presence With more than employees worldwide, WEG is one of the largest electric motors, electronic equipments and systems manufacturers. We are constantly expanding our portfolio of products and services with expertise and market knowledge. We create integrated and customized solutions ranging from innovative products to complete after-sales service. WEG s know-how guarantees our DWB molded case circuit breakers the right choice for your application and business, assuring safety, efficiency and reliability. Availability is to have a global support network Partnership is to create solutions that suits your needs Competitive edge is to unite technology and inovation Molded Case Circuit Breakers

55 Full Circuit Breaker Solutions Know More Dimensions (frames) Currents (A) Thermomagnetic Protection Electronic Protection Breaking capacity I 0 V ac MDW Miniature Circuit Breaker Frame Frame to 6 70 to - Fixed MDWH Miniature Circuit Breaker ) frame 6 to 6 Fixed - ) DW Molded Case Circuit Breaker 60 6 to to 0 00 to 00 Fixed and ajustable / to 00 to Ajustable Ajustable - 6 ACW High-Capacity Molded Case Circuit Breaker 0/60 0 to /6/0 00/60 6 to 0 60 to 00 Fixed and ajustable Ajustable to 00 0 ABW Open Circuit Breaker 00/600 0 to /00/00 000/ to to Ajustable to 600 Note: ) MDWH at 0 V AC I cu = 0 ka. Molded Case Circuit Breakers

Automation Molded Case Circuit Breakers IEC Style. Motors Automation Energy Transmission & Distribution Coatings

Automation Molded Case Circuit Breakers IEC Style. Motors Automation Energy Transmission & Distribution Coatings Automation Molded Case Circuit Breakers IEC Style Motors Automation Enery Transmission & Distribution Coatins www.we.net Molded Case Circuit breakers Molded Case Circuit Breakers Summary Molded Case Circuit

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

DSE201, DSE201 M Compact design with enhanced protection

DSE201, DSE201 M Compact design with enhanced protection DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection

More information

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

RM4JA01F current measurement relay RM4-J - range ma V AC

RM4JA01F current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

WEG Contactors - CWM and CWME Series

WEG Contactors - CWM and CWME Series Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O Characteristics industrial timing relay - 0.3..30 s - type A - 24 V AC/DC, 110..240 V AC - 1 C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range Sep 23,

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically

More information

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

RM4UA33M voltage measurement relay RM4-U - range V V AC

RM4UA33M voltage measurement relay RM4-U - range V V AC Characteristics voltage measurement relay RM4-U - range 30..500 V - 220..240 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay Power consumption

More information

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM4JA32MW current measurement relay RM4-J - range A V AC DC Characteristics current measurement relay RM4-J - range 0.3..15 A - 24..240 V AC DC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers

More information

RM84 miniature relays

RM84 miniature relays RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to

More information

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

RATINGS AND SPECIFICATIONS

RATINGS AND SPECIFICATIONS RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

RM4TR31 three-phase network control relay RM4-T - range V

RM4TR31 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit

More information

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

RM4TA32 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

TeSys protection components

TeSys protection components Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4JA31M current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 220..240 V AC Complementary [Us] rated supply voltage Operating voltage tolerance Main Range of product Product or component type Relay

More information

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70. Characteristics voltage control relay RM17-U - range 9..15 V DC Price* : 70.64 GBP Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

Power Electronics. Semiconductor relay / - contactor

Power Electronics. Semiconductor relay / - contactor Power Electronics Semiconductor relay / - contactor PH 9260 POWERSWITCH 0247349 Semiconductor relay PH 9260.91 Semiconductor contactor PH 9260.91/000/01 AC semiconductor relay / -contactor According to

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 1OC Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

ic60n RCBO 30 ma IEC , IEC , AS/NZS

ic60n RCBO 30 ma IEC , IEC , AS/NZS ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

RM4LA32M liquid level control relay RM4-L V AC

RM4LA32M liquid level control relay RM4-L V AC Characteristics liquid level control relay RM4-L - 220..240 V AC Complementary [Un] rated nominal voltage Operating voltage tolerance Width Output contacts Maximum electrode voltage Maximum electrode current

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics Off-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and

More information

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O Characteristics Star-Delta Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

RM35TF V AC

RM35TF V AC Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information