Adjustable swirl diffuser PDZA TECHNICAL DATA

Size: px
Start display at page:

Download "Adjustable swirl diffuser PDZA TECHNICAL DATA"

Transcription

1 Adjustable swirl diffuser PDZA TECHNICAL DATA

2 Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high ceiling interiors, for example market halls, warehouses, factories etc. The of the diffuser can be adapted to both summer and winter conditions. The air diffusion pattern is controlled by moving internal core outlet with blades. The maximum vertical throw length of m is achieved when the core is in the bottom position. PDZA has an air flow range of between and 10 l/s ( m /h) with a maximal vertical throw length of m. It is only recommended for freely hanging installation. PDZA can be adjusted manually or with the help of an electric actuator. QUICK SELECTION Size Air flow l/s m /h Installation height H P, m Pressure drop Pa PDZA PDZA PDZA PDZA PDZA SPECIFICATIONS Available in sizes, connections from 0 to 00 mm For freely hanging installation Adjustable air diffusion pattern Controlled manually or via electric actuator PRODUCT CODE EXAMPLE Adjustable swirl diffuser PDZA Terminal of size 0, adjustable manually, painted in RAL 90 colour. FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

3 Adjustable swirl diffuser PDZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL PDZA- THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) 0, +K +K +1K 1, PDZA- THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) -K L [m.] 0, 1, PDZA- PRESSURE DROP AND SOUND POWER LEVEL L W 00 p [Pa] L W [db(a)] V [m /h] Heating Cooling FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

4 Adjustable swirl diffuser PDZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL PDZA-1 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) 0, 1 +K +K +1K 1, PDZA-1 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) 7 -K 0, 1, PDZA-1 PRESSURE DROP AND SOUND POWER LEVEL L W p [Pa] L W [db(a)] Heating Cooling V [m /h] FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

5 Adjustable swirl diffuser PDZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL PDZA- THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) 0, 1 +K +K +1K 1, PDZA- THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) 0, -K 1, PDZA- PRESSURE DROP AND SOUND POWER LEVEL L W p [Pa] L W [db(a)] Heating Cooling V [m /h] FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

6 Adjustable swirl diffuser PDZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL PDZA-0 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) 0, 1 +K +K +1K 1, PDZA-0 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) 9 -K 0, 1, PDZA-0 PRESSURE DROP AND SOUND POWER LEVEL L W p [Pa] L W [db(a)] Heating Cooling V [m /h] FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

7 Adjustable swirl diffuser PDZA 7 THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL PDZA-0 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) 1 +K 0, +K +1K PDZA-0 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) 1 -K 0, PDZA-0 PRESSURE DROP AND SOUND POWER LEVEL L W p [Pa] L W [db(a)] V [m /h] Heating Cooling FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

8 Adjustable swirl diffuser PDZA AIR FLOW VOLUME, DISTANCE BETWEEN DIFFUSERS MAXIMUM AIR FLOW VOLUME* 0 t r [ C] 90 q Vmax [l/s x m ] 0 q Vmax [m /h x m ] C C C C C 0 C H p [m] *Assuming that average metabolic activity level is.0 met and clothing insulation is clo. Premises which meet these conditions are e.g. sport halls, warehouses and light industry halls. MINIMUM DISTANCE BETWEEN DIFFUSERS q V [l/s x m ] q D [m /h] q V [m /h x m ] q D [l/s] H p [m] FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

9 Adjustable swirl diffuser PDZA 9 PROJECT DESIGN EXAMPLE PROJECT DESIGN EXAMPLE Definitions q tot total air flow m /h q D diffuser air flow m /h q V volume air flow per square meter m /h x m A served floor area m H p installation height above the floor m t distance between diffuser m t min minimum distance between diffusers m t r room temperature C t v temperature difference between the supply air and the room air K L 0, throw equivalent to 0. m/s in final velocity m H W height of occupied zone m Assumptions Total air flow q tot = m³/h Served floor area A = 000 m Room temperature t r = C Installation height above the floor H p = L 0. + H W Height of occupied zone H W = 1. m 1. Selection of diffuser, size PDZA-0 Assumed number of diffusers, n 1 pcs. Diffuser air flow, q D 1 m /h Throw, L 0, (read from graph). m Installation height above the floor, H p =.0 m Assumed t v for heating + K Min air flow taken from the graph for the diffuser heating 1 m /h Assumed distance between diffusers, t.0 m Volume air flow, q V (from graph) 1.1 m /h x m Max volume air flow per square meter, for H p =.0 m and t r = C m /h x m Min distance between diffusers, t min where q Vmax = m /h x m is not exceeded.9 m. Selection of diffuser, size PDZA-1 Assumed number of diffusers, n 7 pcs. Diffuser air flow, q D m /h Throw, L 0, (read from graph). m Installation height above the floor, H p =.0 m Assumed t v for heating + K Min air flow taken from the graph for the diffuser heating m /h Assumed distance between diffusers, t.0 m Volume air flow, q V (from graph) 1.7 m /h x m Max volume air flow per square meter, for H p =.0 m and t r = C m /h x m Min distance between diffusers, t min where q Vmax = m /h x m is not exceeded.0 m FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

10 Adjustable swirl diffuser PDZA SOUND DATA, DIMENSIONS AND WEIGHT, DIFFUSION PATTERNS SOUND POWER LEVEL Size Correction of sound level K oct in db for octave bands, mean frequency (Hz) The sound power levels for different octave bands are obtained by adding together the sound power level L W, in db(a), and the corrections K oct for the octave bands in the table with the help of the following formula: DEFINITIONS q air flow l/s, m /h Δp t total pressure drop Pa H p installation height m L 0 throw m L w sound power level db(a) L Woct sound power level per octave db(a) K oct octave band correction db ΔL sound attenuation from the duct to the room db DIFFUSION PATTERNS L Woct = L w + K oct Correction K oct is the mean value for the range of application of PDZA. SOUND ATTENUATION Size Sound attenuation in ΔL db for octave bands, mean frequency (Hz) Horizontal air diffusion - cooling. Internal core outlet with blades is moved up. DIMENSIONS AND WEIGHT E ØD1 H C Combined air diffusion. Internal core outlet with blades in the middle position F G ØD Size ØD1 ØD C E F G H Weight (mm) (mm) (mm) (mm) (mm) (mm) (mm) (kg) Vertical air diffusion - heating. Internal core outlet with blades is moved down. FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

11 Adjustable swirl diffuser PDZA 11 GENERAL, PRODUCT CODE CONSTRUCTION AND FUNCTION PDZA is an adjustable ceiling swirl diffuser that is recommended to be mounted directly to the duct. Its diffusion pattern can be changed from horizontal to vertical in order to adapt summer or winter conditions. Position of internal core outlet with blades can be controlled manually or automatically via electric actuator. PDZA is only recommended for freely hanging installation MATERIAL AND SURFACE FINISH Diffuser is made of black steel sheet. PDZA is powder-coated for a high surface finish. The standard colour is RAL 90, 70% of gloss. Electric actuators used in automatic version comply with RoHS directive. INSTALLATION, ADJUSTMENT AND MAINTENANCE The instructions for installation, adjustment and maintenance are available at TECHNICAL DATA AND DIMENSIONING For complete design details, please see the Fläktgroup product selection program SELECT. The program can be found on the Internet at PRODUCT CODE Adjustable swirl diffuser Size (aa), 1,, 0, 0 Flow pattern regulation (b) 1 = manual = by electric actuator Colour (c) 1 = standard RAL 90 X = any other colour from RAL palette Note: Duct connections with a rubber gasket except sizes and 0. PDZA-aa-b-c SPECIFICATIONS TEXT EXAMPLE The PDZA is a ceiling supply swirl diffuser that consists of external casing and internal movable parts, which position can be set due to actual demand in terms of diffusion pattern shape. Unit can be controlled manually or via electric actuators. FläktGroup FG_DC_1GB_PDZA_TE_01111_R0 Specifications are subject to alteration without notice.

12 FG_DC_1GB_PDZA_TE_01111_R0 Copyright 01 FläktGroup PDZA 1 FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment Air Movement Air Diffusion Air Distribution Air Filtration Air Management & ATD s Air Conditioning & Heating Controls Service» Learn more on or contact one of our offices

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB (DYVZ+ATVA) DYVZ DYVB (DYVZ + ATVA) The DYVB is a quiet wall mounted supply air unit that consists

More information

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA TECHNICAL DATA - 0 page Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Diffusers with perforated panels type PAKA, PBKA, PCKA, PDKA, PEKA can be used

More information

Square swirl diffuser PZK(A,B), PWK(A,B)

Square swirl diffuser PZK(A,B), PWK(A,B) Square swirl diffuser PZK(A,B), PWK(A,B) TECHNICAL DATA - 01 page 4 Square swirl diffuser PZK(A,B), PWK(A,B) PZK(A,B) and PWK(A,B) diffusers assort to swirl devices group. Diffuser s gaps are equipped

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

Ceiling diffusers - visible

Ceiling diffusers - visible Ceiling diffusers - visible About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

Floormaster DVQA, quarter-cylindrical terminals

Floormaster DVQA, quarter-cylindrical terminals Floormaster DVQA are quarter-cylindrical supply air terminals for positioning on the floor in a corner. The terminals are designed for displacement air handling in accordance with the Floormaster system

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative

More information

IBIS. Duct diffuser with discs for supply air QUICK FACTS

IBIS. Duct diffuser with discs for supply air QUICK FACTS Duct diffuser with discs for supply air QUICK FACTS 0 flexible distribution pattern Suspended installation Easy installation Modular length: 00 mm Standard colour White RAL 900 -- alternative standard

More information

IBISTM. Duct diffuser with discs for supply air

IBISTM. Duct diffuser with discs for supply air TM Duct diffuser with discs for supply air Quick facts 0 flexible distribution pattern High induction capacity Suspended installation Easy installation Modular length: 00 mm Available in alternative colours

More information

Ventilation grille. Dimensions

Ventilation grille. Dimensions Ventilation grille B0 Dimensions B+/A+ B-/A- Description B0 is a rectangular aluminium grille with fixed horizontal bars. B0 is used for both supply and exhaust air, and is supplied as standard with springs

More information

DKC. VARIZON Displacement unit with adjustable spread pattern

DKC. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of room which require large airflows Simple installation Cleanable

More information

NORDgrille Internal grilles

NORDgrille Internal grilles NORDgrille Internal grilles NORDgrille Contents RSP/RSV General grille RPS/RPV General grille RPSL/RPVL Floor grille RSO Transfer air grille RSL Transfer air grille RSM Transfer air grille RSI Exhaust

More information

ROL and ROL-S. climecon.fi

ROL and ROL-S. climecon.fi ROL and ROL-S The stylish and silent nozzle duct ROL is designed for rooms requiring large air volumes distributed evenly and without draught. The functional entity is completed by the ROL-S Adjustment

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions 1 / 0 00 0 500 2 / 0 00 0 Description is a supply grille made from aluminum with curved adjustable blades, oriented 1-way or 2-way horizontal or vertical both for wall and ceiling

More information

DRI. VARIZON Displacement unit with adjustable spread pattern

DRI. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install

More information

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser 12 in. x 12 in. Face 4 Neck Velocity (fpm) 400 00 00 00 00 900 00 1200 1400 0 Velocity Pressure (in. w.g.)..01.022.031.040.00.02.090.122..013.021.030.041.04.0.04.121.1.21 Flow Rate (cfm) 3 44 2 1 0 4 122

More information

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176 B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5

More information

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR , type DW-N Swivel jet nozzle, type DW-V Twist nozzle, type DW-V-...-DR DS 1 E 0.00/ and twist nozzle Preliminary remarks It is advisable to use nozzles to air-condition large spaces where the supply air

More information

S u p p l y a i r h o o d J S I

S u p p l y a i r h o o d J S I Supply air hood JSI PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air Pressure loss & sound data Supply air 9 Supply

More information

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

Grilles Type AR. AE for return air 1 / 1.3 / B / 1 Grilles Type for return air 1 / 1 / B / 1 Contents Description Construction Cover Page 1 Contents 2 Description 2 Construction 2 Materials Standard Sizes Technical Data Technical Data Type Nomenclature

More information

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP DCV-SP Pressure control 24VAC + Communication DIN 24VAC + Communication AIN DCV-SP SMART DAMPERS & MEASURING UNITS Pressure control DCV-SP AOUT RELAY 1(14) Contents Page DCV-SP Introduction... 3 Functional

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

SIRI. Measurement and control damper QUICK FACTS

SIRI. Measurement and control damper QUICK FACTS Measurement and control damper QUICK FACTS Type-approved method of measurement Short installation length Can be cleaned Low flow-generated noise level High measurement accuracy Ductwork leakage class C,

More information

CEILING SWIRL DIFFUSER MLD

CEILING SWIRL DIFFUSER MLD CEILING SWIRL DIFFUSER MLD Proektasi Makriyianni Ano Ilioupoli P.O.BOX: 6 P.C.: 1 Thessaloniki GREECE Tel.: +0 687 FAX: +0 68047 WEB SITE: www.aerogrammi.gr E-MAIL: info@aerogrammi.gr MLD CEILING ROUND

More information

U V-Tu r b o h o o d s

U V-Tu r b o h o o d s U V-Tu r b o h o o d s Product description, Product code Parts Functioning principle Dimensions Exhaust air, pressure loss and sound data Supply air, pressure loss and sound data Distribution of supply

More information

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper SLO DIFFUSERS ALS SERIES SLO DIFFUSER For, and Installation Series ALS Architectural Linear Slot Diffusers are designed for installation in the ceiling, sidewall or sill and are recommended for supplying

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers Swirl diffuser O-8 Square or round front plate with radial deflector arrangement Plastic deflectors Possible olume control damper in spigot Foam sealing on the flange St RA 900 C VENTIATING GRIES, VENTIATING

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

BAR GRILLE TYPE: A-600

BAR GRILLE TYPE: A-600 Tel: Sales 0 I Web: www.grada.co.uk TYPE: A00 Installation dimensions AC00 AA00* / AD00 + GR00 0. (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* () (L) ( L) AB00* / AE00 + GR00 (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* ( L)

More information

Circular and semi-circular displacement outlet Q-Z...

Circular and semi-circular displacement outlet Q-Z... and semi-circular Q-Z... DS 0 E 0.0 and semi-circular Preliminary remarks The circular is installed free standing in the room or - preferably the semicircular model - placed in front of a wall or pillar

More information

LOOK hidden linear diffusers

LOOK hidden linear diffusers hidden linear diffusers MADEL The hidden linear diffusers are designed to combine the aesthetics with the technical performance. They can be mounted in false ceilings hiding the frame with filler and leaving

More information

Room controller STRA-17

Room controller STRA-17 Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers Swirl diffuser OD-7 Fixed blades Different installation possibilities Three possible diffuser shapes St R 90 CD OD-7/R OD-7/K OD-7/RC OD-7/K/PM F 9 x9 φd1 C C F x F C φ D2 φ D 1 9 x 9 Size ФD1 ФD2 ФD F

More information

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern.

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern. Catalogue Swirl Ceiling Swirl Diffuser Fixed Air Pattern www.air-diffusion.co.uk sales@air-diffusion.co.uk Content Introduction... Technical Description... Performance Data... Quick Selection Data... Selection

More information

LDK Slot Diffusers. Description. Throw directions. 2

LDK Slot Diffusers. Description. Throw directions. 2 Slot Diffusers LDK LDK Slot Diffusers Description LDK linear slot diffusers are designed to meet high comfort requirements and modern slot diffuser application standards. LDK slot diffusers, providing

More information

Rectangular straight silencer

Rectangular straight silencer silencer DLD Dimensions b a l Description DLD has a conventional design with dimensions that not exceed the corresponding connection dimensions. The silencer can be manufactured in all standard duct sizes.

More information

NORDsilencers Ventilation system silencers

NORDsilencers Ventilation system silencers NORDsilencers Ventilation system silencers NORDsilencers 0 Contents General NRF 0/NRP 0 Silencer NRF 00/NRP 00 Silencer NRFB 0/NRPB 0 Silencer NRFB 00/NRPB 00 Silencer NMF/NMP Silencer NMFE/NMPE Silencer

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to SmartAisleTM SmartAisle TM Energy-efficient use of existing cooling power in data centers 1.50 to 1.58 1.49 Emerson Network Power Smart Aisle TM The consistent physical separation of cold zones from warm

More information

Hudevad Plan XV. technical datasheet

Hudevad Plan XV. technical datasheet technical datasheet Key benefits Minimalistic Scandinavian design Matches any architecture Vertical design Ideal for rooms with high ceilings and limited wall space Elegant flat front an be used either

More information

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers Incorporating V2.2 Product spec >>> > Series CD - Ceiling diffusers Diffusers Ceiling (Louvre faced) Recommended for: Ceiling Supply Overview Excellent diffusion characteristics CD4 tile replacers normally

More information

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH*** VRF Technical Data Book Slim duct for America (R41A, 6Hz, HP) Model : AM***FNLDCH*** History Version Modification Date Remark Ver.1. Release Slim duct for America (R41A, 6Hz, HP) 1.11.4 - Ver.1.1 1.12.28

More information

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS THINGS HAVE CHANGED, AND SO HAVE VENTILATION SYSTEMS. WALL SYSTEM HATCH SOLUTIONS ROOF SYSTEM A NEW CONCEPT IN HATCH VENTILATION SYSTEMS.

More information

Reliability and extended operation

Reliability and extended operation CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter

More information

Control components for VAV terminal units

Control components for VAV terminal units .3 X X testregistrierung Control components for VAV terminal units Type For contaminated extract air or for pressure control Modular control components for VAV terminal units, especially for aggressive

More information

HERZ Actuator 7708, 7990

HERZ Actuator 7708, 7990 HERZ Actuator 7708, 7990 Data sheet for 7708, 7990 Issue 1116 Dimensions Dimensions Installation height Dimensions Installation height Dimensions Installation height Page 1 Models HERZ Actuator 2-point,

More information

Universal Controller

Universal Controller 3 342 Universal Controller For comfort control in HVAC & R-Systems Standalone electronic universal controller with P or PI response Operating voltage in accordance to type AC 24 V Control application selectable

More information

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications Product Overview Bose FreeSpace DS 16S and FreeSpace DS 16SE loudspeakers are high-performance, surfacemount loudspeakers designed for background music and speech reproduction in a wide range of commercial

More information

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are

More information

Product Library and ISO 16757

Product Library and ISO 16757 Product Library and ISO 16757 Wolfgang Wilkes Bjørn Stangeland Manfred Pikart 1 Building information modelling and catalogues Building Owner s Data : Requirements, Restrictions... Manufacturer s Data:

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world

More information

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks Technical Concept Tunnel Air Shower All Types Air Shower / Air Locks Tunnel Air Shower Technical Concept Product Description Personnel air showers minimize the transfer of dust particles on cleanroom clothing

More information

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

RC-CDTO. Pre-programmed room controller with display, communication and three-point control revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control

More information

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1 TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788

More information

STRA-17 Room controller. Installation and maintenance manual. Content

STRA-17 Room controller. Installation and maintenance manual. Content Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

Sealed Enclosure Cooling Air Conditioners

Sealed Enclosure Cooling Air Conditioners SPECTRACOOL Compact Indoor INDUSTRY STANDARDS UL/cUL Listed; Type 12; File No. SA6453 for N17 UL/cUL Listed; Type 12, 3R, 4, 4X optional; File No. SA6453 and UR/cUR Recognized on select models for N16

More information

Precision Cooling Mission Critical Air Handling Units

Precision Cooling Mission Critical Air Handling Units M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly

More information

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage The ideal extractor for industrial environments. New technology in combination with new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability.

More information

TLS RGBW CUT SHEET DESCRIPTION FEATURES

TLS RGBW CUT SHEET DESCRIPTION FEATURES CUT SHEET TLS RGBW DESCRIPTION TLS RGBW offers an impressive solution with its adjustable RGBW LED boards that can be set up to 16.7 million colors or pure white. This unrivalled tensioning system can

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS Series Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase V- 5Hz

More information

C200 PRECISION PASSIVE LOUDSPEAKER. FEATURES: 2-way portable Precision Passive loudspeaker system APPLICATIONS

C200 PRECISION PASSIVE LOUDSPEAKER. FEATURES: 2-way portable Precision Passive loudspeaker system APPLICATIONS C200 Featuring legendary Mackie sound quality and durability, the lightweight C Series 2-way Precision Passive loudspeakers deliver optimum performance in portable PA, stage monitor and permanent installation

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

TOSHIBA DesignAIRS. Help & Guide Manual

TOSHIBA DesignAIRS. Help & Guide Manual TOSHIBA DesignAIRS Help & Guide Manual Contents 1. MAIN TOOLBAR... 3 1.1. Tools / Options... 3 1.1.1. Application Settings... 3 1.1.2. Email Settings... 4 1.1.3. Internet Connection Settings... 4 1.1.4.

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS HV-STYLVENT Series 688 679 Shutter Reversible Natural ventilation position Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied

More information

Noises sources Technical datasheet

Noises sources Technical datasheet Noises sources Technical datasheet NOISE SOURCES GENERAL POINTS 01dB offers a complete range of measuring instruments, software and accessories for building noise measurements. A complete range of noise

More information

XENO 8. User & Installation Manual.

XENO 8. User & Installation Manual. XENO 8 User & Installation Manual www.audac.eu 2 Introduction 8 Full range loudspeaker cabinet The XENO series is a loudspeaker range specifically designed for fixed audio installations in modern environments,

More information

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint

More information

VALLOX BLUESKY AIR DISTRIBUTION SYSTEM

VALLOX BLUESKY AIR DISTRIBUTION SYSTEM VALLOX BLUESKY AIR DISTRIBUTION SYSTEM FLEXIBLE AND EASY-TO-INSTALL AIR DISTRIBUTION SYSTEM Vallox BlueSky is an easy-to-install air distribution system that consists of a flexible ventilation duct made

More information

PAGING HORN SPEAKERS SC-630/SC-630M. Both high-impedance (70V/100V lines) models and lowimpedance (8Ω) models available.

PAGING HORN SPEAKERS SC-630/SC-630M. Both high-impedance (70V/100V lines) models and lowimpedance (8Ω) models available. PAGING HORN SPEAKERS SC-6/SC-6M SC-615/SC-615M SC-63/SC-63M DESCRIPTION TOA's SC Series Paging Horn Speakers are designed for both indoor and outdoor applications. The lineup includes six models rated

More information

Building Cleanrooms. - Regulations, Air-Handling, Design & Construction -

Building Cleanrooms. - Regulations, Air-Handling, Design & Construction - Building Cleanrooms - Regulations, Air-Handling, Design & Construction - Created by Michael Starke, Solutions and Handling GmbH, Germany Tel.: +49-2152-553800, Fax: +49-2152-553805, mail: info@solutions-handling.com

More information

INTERIOR RECESSED DOWN LIGHTS

INTERIOR RECESSED DOWN LIGHTS INTERIOR RECESSED DOWN LIGHTS I SIRIO 1. Round Recessed down Light 2. Body in Pure aluminum 3. Finish Powder Coated Matt White 4. Adopt an appropriate heat sink material and excellent heat simulation design

More information

Variable Flow Rate Control Unit

Variable Flow Rate Control Unit VAV Produktdata TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Variable Flow Rate Control Unit Model BVAV-R: VAV unit that has circular section. BVAV-RS: VAV terminal unit. BVAV-Q: VAV unit that has

More information

roller shutters ALUMINIUM ROLLER SHUTTERS FOR SPECIAL VEHICLES

roller shutters ALUMINIUM ROLLER SHUTTERS FOR SPECIAL VEHICLES roller shutters ALUMINIUM ROLLER SHUTTERS FOR SPECIAL VEHICLES ROLLER SHUTTERS INTRODUCTION The main target of company SRS is to offer competence and reliability to the customers in the production of aluminium

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, TVT OR EN

Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, TVT OR EN Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS

More information

CHAPTER 5. Special Cases

CHAPTER 5. Special Cases CHAPTER 5 Special Cases OVERHANGS To be treated as an overhang, slotted and louvered shading devices must have the slats arranged so that no direct solar radiation penetrates the overhang at any time during

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

Product data sheet : Electric height adjustable desk frame

Product data sheet : Electric height adjustable desk frame Product data sheet : Electric height adjustable desk frame 501-27 327990.2 Table of contents Packing details.... 3 Main measures and specifications.... 4 Tabletop drillings.... 5 Assembly and use... 6

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

VAV compact controller KNX / PL-Link

VAV compact controller KNX / PL-Link s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air

More information

Tacit 4G. Hush. Projector Enclosures 20-45K. Fourth eneration. Projector Enclosures

Tacit 4G. Hush. Projector Enclosures 20-45K. Fourth eneration. Projector Enclosures 4G 20-45K 4G Fourth eneration Tempest is the world s leading manufacturer of large format indoor projector enclosures for noise attenuation in presentation suites, digital cinema, live theatre and concert

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½ SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM 5-Slot 6-Slot 7-Slot 8-Slot Airflow, cfm/ft. 5 10 16 21 26 31 36 42 47 NC (Noise Criteria) - - 20 27 32 37 40 44 46 Horizontal 1-1-6 3-6-12

More information

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0 Control engineering information VARYCONTROL VAV Units flow rate controller BC0 BF0 The art of handling air Contents 1 General information 3 Correct use 3 Materials 3 Maintenance 3 2 Field of application,

More information

GPE4P ECONOMY PARKING SYSTEMS

GPE4P ECONOMY PARKING SYSTEMS GPE4P ECONOMY PARKING SYSTEMS PARKING SYSTEM ECONOMY Parking system designed for the collection of parking fees, suitable for both public and private car parks municipal car parks, parking at accommodation

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Data sheet AS-20 / ASP-20. Arc- Series. Architectural Sound Design.

Data sheet AS-20 / ASP-20. Arc- Series. Architectural Sound Design. Data sheet AS-20 / ASP-20 Arc- Series Architectural Sound Design. AS- 20 / ASP-20 subwoofer system Fohhn AS-20 / ASP-20 Compact bass system, 400 W, 1 12, vented design. Description The Fohhn AS-20 is a

More information

Ceiling Concealed Split System C Series

Ceiling Concealed Split System C Series Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -H Performance High Plume April 07 Laboratory Exhaust Systems Model Vektor -H Table of Contents Vektor-H Specification Chart.... Plume Height Calculation... Quick Select

More information

NORDdiffuser Diffusers

NORDdiffuser Diffusers NORDdiffuser Diffusers 0 NORDdiffuser Contents DSS Supply air valve DSE Exhaust valve DVP Supply air valve DVS Exhaust valve SFU Supply air valve DKC Ceiling diffuser DKA Ceiling diffuser 0 DSK-P Supply

More information

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications Product Overview The Bose FreeSpace DS 100SE loudspeaker is a high-performance, surface-mount loudspeaker designed for foreground music and speech reproduction in a wide range of commercial applications,

More information

CBT 100LA Constant Beamwidth Technology

CBT 100LA Constant Beamwidth Technology CBT LA Constant Beamwidth Technology Line Array Column Loudspeaker with Sixteen 5 mm (2 in) Drivers Key Features: Patent-pending Constant Beamwidth Technology provides constant directivity up to the highest

More information

Homepage > Prodotti > Unità di regolazione > VARYCONTROL > silenziatore secondario > Type TX. Type TX

Homepage > Prodotti > Unità di regolazione > VARYCONTROL > silenziatore secondario > Type TX. Type TX Homepage > Prodotti > Unità di regolazione > VARYCONTROL > silenziatore secondario > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary

More information