Switchboards. Product Overview

Size: px
Start display at page:

Download "Switchboards. Product Overview"

Transcription

1 Switchboards Product Overview A switchboard distributes large electrical current used by electrical equipment and building requirements. Applications can range from a small office building to a major industrial complex. Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets but rather free standing on a poured cement slab. Commercial metering switchboards provide electrical system distribution and metering for commercial applications. Using standard Pow-R-Line C construction, these switchboards incorporate metering sections with tenant feeder circuits. Pow-R-Line C Distribution Switchboards combine a space-saving design with modular construction and increased systems rating to provide economical and dependable electrical system distribution and protection. Pow-R-Line I Switchboards are engineered in a new compartmentalized design for applications where greater safety is required. A variety of configurations are possible including utility metering, customer metering, and main devices. Integrated Facility Switchboards use the Pow-R- Line C group mounted switchboard design to integrate separate electrical distribution and control equipment into a single factory assembled and connected package. Eaton s innovative IFS incorporates advanced Eaton electrical distribution equipment, including Pow-R-Command, Smart Breakers, and building automation into one spacesaving structure; therefore reducing installation time and man-power needed. Wall Mounted IFS provides electrical control, monitoring, and power quality while providing valuable square footage savings. For more information and panelboard descriptions and specifications, refer to the Distribution Catalog. Or,

2 Accessing the Take-off General Tab To configure Switchboards, you must use the Bid Manager Take-off. 1. Click the Take-offs menu, point to Switchboards, and then click on the desired type of Switchboard. 2. Complete the information on each tab as appropriate. For more information on general take-off features, see Working with Take-offs job aid. Click the drop-down menus and/or select check boxes to specify general requirements. Note: When you change the type of switchboard from within the take-off, the default settings change to reflect the selection. There cannot be any placed structures on the Layout tab when changing the switchboard type. When selecting the Use this Minimum Interrupting option, you must also specify the amp rating in the drop-down menu adjacent to the selection. Service Entrance Label must be selected to continue building the switchboard. The Switchboard ID Nameplate option will be available once there are structures in the layout tab.

3 Addition to Existing Switchboard Enter the original GO number and the original item number in the fields, and select which side the new switchboard will connect with the existing switchboard. Adding Power Xpert Communications Options Use the Power Xpert Communications button to quickly and accurately select the appropriate Power Xpert connectivity capabilities for the take-off. Power Xpert hardware components, such as gateways and meters, give the ability to gather data from each piece of equipment within the power system. With Power Xpert Architecture, each communicating device in the power system is connected to a computer network using an Ethernet communication protocol. Once connected, the facility manager can measure and monitor the equipment, regardless of its age or manufacturer. Power Xpert components can help synchronize the clocks on the equipment to provide accurate, usable data for the entire power system. When an event like a lightning strike happens, Power Xpert can track the effects in the power system within millisecond accuracy. To add Power Xpert Communications options: 3. Click the Power Xpert Communications button. 4. Click the check box next to each option to add. Note: For more information about these options, in the Power Xpert Communications dialog box, click the Power Xpert Help link.

4 Options Tab The Options tab is used to select various options for the switchboard, including seismic labels, solid bottom plate, nameplates, and heater package. Select the appropriate options for the switchboard. Note: To assign naming for devices when selecting Nameplate on all Devices, go to the Device Mods tab. Layout Tab The Layout tab is used to select the necessary structures and devices for the switchboard. There are three basic types of structures when simplified Incoming Main Feeder Sections can include more than one type. For example, one section can include an incoming section with a main breaker and feeder section all-in-one. Incoming structures include either a main device or main lugs for landing incoming cables and are sometimes referred to as a pull structure when using main lugs only.

5 Main structures usually include a main breaker or switch for disconnecting the service to the rest of the lineup. Feeder sections include a chassis or area for mounting distribution breakers. Note: If the parts bin is not viewable on the right-hand side of the screen, click in the open grey area in the center of the screen to make it appear. Clicking on a structure will show the available options in for that structure in the parts bin. Selecting a Structure While moving the cursor over the structures, the corresponding power flow diagram appears in the top right corner. Select a structure by clicking on the yellow picture icon within the parts list. Changing the Zoom The Zoom setting adjusts the layout view of the structures, to allow viewing of many structures on the screen at one time. Click, hold and drag the zoom arrow left to shrink the view or right to increase the view.

6 Click Reset to set the Zoom back to 100%. Selecting the Utility Structure Two types of utility structures are available: incoming utility structure or a basic utility structure. Click a gray bar in the parts bin area for the type of utility structure Select the utility structure icon from the parts bin. Choose the correct utility information based on the area's utility requirements in the Structure Properties window. Choose the Utility Name Location from the drop down menus. Note: Combinations of location and Utility of East Coast and NEMA or West Coast and EUSERC, show the Nema Utility Name activated. Select the appropriate Utility Drawing, then select the Side of the Pull Structure. Note: Terminals and Door Arrangements can be changed here or in the properties for the section later. Enter the Customer Address if available. Click OK. Selecting the Main Device The main device structure is used to switch the power flow for the rest of the structure. NEC and UL require either a Single Main Service Disconnect or a Maximum of 6 Service Disconnects if there is NO Single Main Device in the equipment (Main Lugs Only).

7 To add a main device structure, 1. Click the Main Structure bar in the parts bin. 2. Select the appropriate structure from the list. 3. Click on the main breaker location in the structure. 4. To add a Main Breaker, double-click Main Brkr.(Ind.Mtd) in the parts bin. Note: The status bar (at the bottom of the screen) displays the name of the item that is selected in the layout. 5. Complete the breaker properties. 6. Click the Mods button to add modifications to the main breaker. 7. Click OK to save the breaker options. Selecting the Feeder Structure The feeder structure is a distribution structure that can contain breakers, switches, customer metering, SPD, or Web Enabled Communications compartment. 1. Click the Feeder Structure bar in the parts bin. 2. Click a Feeder Structure icon. Note: The 38X Chassis feeder structure is used only when breaker interface module will be needed with OPTIM breakers. 3. Click on the center of the feeder structure to add devices. 4. Double-click on the device from the parts bin to add.

8 Deleting a Structure To delete a structure, click on the structure and: 1. Press DELETE on the keyboard or, 2. Press the delete button in the toolbar or, 3. Right-click on the structure and then select Cut Structure. Adding Modifications to the Structure To add modifications to a structure, double-click the structure. To change the structure properties, right-click on the structure and select Structure Properties. IFS Distribution Structures Integrated Facility Switchboards (IFS) use the Pow-R-Line C switchboard design to integrate traditionally separate electrical distribution and control equipment into a single space-saving factory assembled and connected package. The service entrance equipment can be integrated with multiple lighting and appliance branch panelboards into a compact front accessible group mounted switchboard. Where multiple panelboards are used in the same electrical room as a conventional distribution switchboard or power panelboards, the integrated design will significantly reduce equipment space requirements as well as reduce installation time and costs. Other associated equipment can also be integrated into the assembly, including dry-type transformers, time clock space, lighting control, electronic controls, surge protection, customer metering and energy monitoring devices. Depending upon the application, other user defined equipment such as a subsystem control package may also be incorporated. Adding an IFS Structure 1. Select an IFS compartment from the IFS Distribution Structure bar in the parts bin. 2. Click on the compartment structure in the layout to display the optional equipment in the parts bin. 3. Double-click the option from the parts bin and complete the characteristics for that item in the window that is displayed.

9 Importing IFS Panelboards IFS panelboards can be imported from other bases and alternates into your current switchboard. Importing involves two stages: 1. Import the panelboard, which places it in a holding area at the bottom-right of the Layout tab 2. Select the imported panelboard and place it in a switchboard structure. Note: Panelboards do not automatically change as you modify the switchboard configuration. If you make changes to a switchboard that could affect the engineering of any existing panelboard items, then you must revisit the affected panelboards and make changes where necessary. To import an IFS panelboard: 1. Click Import from the file menu and then click Import Panelboard. 2. Double-click a folder, then a job, and then a base or alternate. 3. Click each panelboard that you want to import and then click the Open button. The panelboard(s) selected is listed in the bottom-right area of the Layout tab. If the panelboard consists of multiple items, then it imports as separate items. Placing an Imported Panelboard 1. On the Layout tab, on the left side, click a structure in which you wish to place the imported panelboard. 2. In the bottom-right area of the window, click the panelboard that you wish to place. 3. Click the left arrow in the bottom-right area to place the panelboard in the structure. Adding a Dry Type Transformer 1. Double-click Dry Type Transformer from the device list to add it to the structure. 2. Enter a designation for the dry type transformer. 3. Configure the transformer options. 4. Click OK. Note: A dry-type transformer can only be added to a bottom compartment.

10 Adding a Switchboard Chassis A switchboard chassis and other components can be added to an IFS structure. Other components include: main breakers, feeder breakers, TVSS, and customer metering. The 22X switchboard chassis fits in a top or bottom compartment structure and the 50X switchboard chassis fits in a single compartment structure. 1. Double-click a Top or Bottom Swbd Chassis (22X). 2. To add a designation, enter the name of the chassis designation. 3. Configure the switchboard chassis, and then click the Done button. Adding an Wall Mount ATS (Automatic Transfer Switch) There are a variety of automatic transfer switches depending on the IFS structure that can be added. 1. Double-click one of the following devices: Top Wall Mount ATS Bottom Wall Mount ATS Note: The Automatic Transfer Switch take-off appears. Some of the options are already selected based on the configurations you have already made to the switchboard. 2. Configure the automatic transfer switch. 3. Save the automatic transfer switch and close the window. Adding an Automatic Transfer Switch Structure 1. In the Structure bin, click the Automatic Transfer Switch Structure bar. 2. Click on a type of structure to add to the layout. 3. Click on the structure in the layout and then double-click on Automatic Transfer Switch from the parts bin. Note: Some of the options are already selected based on the configurations already made to the switchboard. 4. Save the automatic transfer switch and close the window.

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

IPaCS Equipment Overview Modular Panelboard System Integrated Power Center Integrated Power Center

IPaCS Equipment Overview Modular Panelboard System Integrated Power Center Integrated Power Center Table of Contents Section 0 Integrated Power and Control Solutions (IPaCS) Equipment IPaCS Equipment Overview 0- Modular Panelboard System 0-3 Integrated Power Center 0-3 Standby Power Connection Solutions

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

PDI Modular Compact Remote Power Panel

PDI Modular Compact Remote Power Panel Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications

More information

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

DIVISION 16 SECTION Surge Protective Device Submittal (SPD) DIVISION 16 SECTION 16289 Surge Protective Device Submittal (SPD) PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary

More information

Power-Style QED-2, Series 2 Low Voltage Switchboards

Power-Style QED-2, Series 2 Low Voltage Switchboards Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................

More information

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical Spec Interpretation The purpose of this PowerPoint is to highlight the areas of the written spec and electrical drawings which contain the information required to determine a TPS part number for quoting

More information

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289 PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289 PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1.1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary

More information

White Paper. UL Standards for Power Control System Equipment

White Paper. UL Standards for Power Control System Equipment White Paper UL Standards for Power Control System Equipment UL Standards for Power Control System Equipment An Introduction to UL 891 and UL 1558 Commercially available Power Controls Systems (PCS) can

More information

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect

More information

IPaCS Equipment Overview Integrated Power Center (IPC) Integrated Power Center 2 (IPC2 ) 10-4

IPaCS Equipment Overview Integrated Power Center (IPC) Integrated Power Center 2 (IPC2 ) 10-4 Download Section 10 PDF Table of Contents Section 10 Integrated Power and Control Solutions (IPaCS) Equipment IPaCS Equipment Overview 102 Modular Panelboard System (MPS) 103 Integrated Power Center (IPC)

More information

1 General Principles. General Principles. In this chapter 1-1

1 General Principles. General Principles. In this chapter 1-1 1 General Principles In this chapter 1 General Principles 1.1 User Interface 1.2 Title bar 1.3 Menu bar 1.4 Standard Toolbar 1.5 The drawing area 1.6 Component tabs 1.7 Status Bar 1.8 Manipulating Components

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements Change History Date Description of Change Pages / Sections Modified 6/15/16 Updated division section from 16289 to 26 35 00, removed references to other section numbers 10/14/14 Amend text in section B

More information

THE SURGE PROTECTION SOLUTION

THE SURGE PROTECTION SOLUTION THE SOLUTION Unique product features and benefits never before offered in the surge protection industry POWER QUALITY INTERNATIONAL, LLC 2404 Merchant Ave., Odessa, Florida, USA 33556 (888) 539-7712 PowerQuality.net

More information

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description... .1 Transfer Switch Equipment Product Selection Guide.................................... Product Description....................................... Application Description......................................2

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually

More information

Aurora Multi-image System Control Software. User Manual

Aurora Multi-image System Control Software. User Manual Aurora Multi-image System Control Software User Manual Product Information Model: Aurora Controller Software Version: V010200 Release Date: January 18th, 2017 Company OSEE TECHNOLOGY CO., LTD. Contact

More information

E3xA, E3xB, E3xC, E3xE

E3xA, E3xB, E3xC, E3xE ZL0140-0C Page 1 of 21 2017 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 0717 Commissioning Guide Power Monitoring E34E E31 * E30E & E31E E34A E30 *The CE mark indicates RoHS2

More information

SECTION ELECTRIC METERING

SECTION ELECTRIC METERING SECTION 26 27 13 ELECTRIC METERING SPEC WRITER NOTES: Use this section only for NCA projects Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION SURGE PROTECTIVE DEVICES

SECTION SURGE PROTECTIVE DEVICES SECTION 16289 PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Surgelogic Surge Protective Device I-Line Plug-On Unit Series Surgelogic Surge Protective Device I-Line Plug-On Unit Series Catalog 1310CT0201R5/07 2007 Class 1310 CONTENTS Description Page Product Description.................................................. 2 Application

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

ASCO SERIES 300 Manual Transfer Switch Solutions

ASCO SERIES 300 Manual Transfer Switch Solutions ASCO SERIES 300 Manual Transfer Switch Solutions When power fails, businesses suffer. For some organizations, a permanent generator is too costly. Instead, permanent means for quickly connecting a portable

More information

OrgPublisher Advanced Box Layout Editor

OrgPublisher Advanced Box Layout Editor OrgPublisher Advanced Box Layout Editor OrgPublisher Table of Contents Table of Contents... 3 Using the... 3 Arranging Chart Box Sections... 3 Sizing the Chart Box Section... 4 Moving, Deleting, or Resizing

More information

1. Move your mouse to the location you wish text to appear in the document. 2. Click the mouse. The insertion point appears.

1. Move your mouse to the location you wish text to appear in the document. 2. Click the mouse. The insertion point appears. Word 2010 Text Basics Introduction Page 1 It is important to know how to perform basic tasks with text when working in a word processing application. In this lesson you will learn the basics of working

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:

More information

BSPD Surge Protective Devices

BSPD Surge Protective Devices BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features

More information

Pow-R-Command System Overview

Pow-R-Command System Overview July 2003 - System Overview Technical Data Table Of Contents System General 2 Applications for System 2 The Need For Lighting Control 2 Energy Costs 2 Software Control 2 Secure Network & Distributed Intelligence

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION SECTION 16709 TRANSIENT VOLTAGE SURGE SUPPRESSION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Transient Voltage Surge Suppression (TVSS) devices, also known as Surge Protective Devices (SPDs), for

More information

Rapsody User's guide. Rapsody. User's guide. December Page 1

Rapsody User's guide. Rapsody. User's guide. December Page 1 Rapsody User's guide December 2008 Page 1 Page 2 Contents Overview 5 Welcome to Rapsody 5 Homepage 6 Main project building steps 8 Define switchboard characteristics 10 Define the switchboard characteristics

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

i-3 Control Technology

i-3 Control Technology i-3 Control Technology Submittal Guide www.usa.siemens.com/i-3 Contents P1 Series Lighting Panel 4-6 i-3 Controller 7 SIPOD specifications 7-8 Inputs and Communications 9 Protocol Connections System Connections

More information

PowerPoint 2016 Building a Presentation

PowerPoint 2016 Building a Presentation PowerPoint 2016 Building a Presentation What is PowerPoint? PowerPoint is presentation software that helps users quickly and efficiently create dynamic, professional-looking presentations through the use

More information

TSC Schneider-PDI Agenda

TSC Schneider-PDI Agenda TSC Schneider-PDI Agenda General Electrical Power Layouts and Equipment Single Phase UPS s Three Phase UPS s Trends In Data Center Power Distribution Data Center Cooling Trends and Products Jim Tubbesing

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak SIEREK switchgear Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak SIEREK Metal-Enclosed Interrupter Switchgear Selection and pplication Guide SIEREK medium-voltage metal-enclosed interrupter

More information

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.

More information

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command OPERATION MANUAL MV-410HS Layout Editor Version 3.0 - higher Command Command Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410HS

More information

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe. PowerPak 2 Power Distribution Unit Flexible. Configurable. Intelligent. Safe. PDI PowerPak 2 Power Distribution Unit Following in the footsteps of numerous PowerPak designs PDI is proud to release PowerPak

More information

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL

More information

Word 3 Microsoft Word 2013

Word 3 Microsoft Word 2013 Word 3 Microsoft Word 2013 Mercer County Library System Brian M. Hughes, County Executive Action Technique 1. Insert a Text Box 1. Click the Insert tab on the Ribbon. 2. Then click on Text Box in the Text

More information

The CAP Panel Builder technology is designed to construct and manage configurations of stack panel products.

The CAP Panel Builder technology is designed to construct and manage configurations of stack panel products. About The CAP technology is designed to construct and manage configurations of stack panel products. Use the intuitive to assemble the components and control properties of stackable panels such as top

More information

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards.

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards. SECTION 26 24 16 - PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SISpro building 2.1. User's reference manual

SISpro building 2.1. User's reference manual SISpro building 2.1 User's reference manual SISpro building 2.1 Page 2 Contents Overview....5. Project step....13. Design step....17. Single line diagram step....191. Quotation step....195. Order form

More information

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation SECTION 26 24 16 PANELBOARDS PART 1 -GENERAL 1.1 SUMMARY A. Section includes distribution and branch circuit panelboards, electronic grade branch circuit panelboards, [and load centers]. 1.2 REFERENCES

More information

WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM Revised 4/30/ Electrical Systems

WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM Revised 4/30/ Electrical Systems SECTION 26 09 13 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This section describes the metering, communications, and visualization requirements for a modular, scalable

More information

Powering innovation. Powering efficiency. Powering home

Powering innovation. Powering efficiency. Powering home Powering efficiency Powering home DISCONNECTS The best prices & selection in Siemens general, industrial & heavy duty safety switches for every application. Powering innovation Illustrating the diverse

More information

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

C. New or replacement products installed in existing facilities shall be consistent with existing equipment. September 2012, rev 00 26 2923 Variable Frequency Controllers PART 1. GENERAL 1.01 Description A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width

More information

Integrated Equipment Solutions

Integrated Equipment Solutions Integrated Equipment Solutions Protect your revenue stream with integrated solutions to keep your equipment and store running 24/7. Integrated Equipment Solutions 1 From fueling controls, to interior and

More information

Free-Stand Disconnects and Accessories

Free-Stand Disconnects and Accessories 763.422.2600 Spec-00067 L763.422.2211 Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Enclosure, Type 1 INDUSTRY STANDARDS

More information

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect. How SPDs Work In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect. A useful analogy makes this clearer. Consider

More information

Clip Art and Graphics. Inserting Clip Art. Inserting Other Graphics. Creating Your Own Shapes. Formatting the Shape

Clip Art and Graphics. Inserting Clip Art. Inserting Other Graphics. Creating Your Own Shapes. Formatting the Shape 1 of 1 Clip Art and Graphics Inserting Clip Art Click where you want the picture to go (you can change its position later.) From the Insert tab, find the Illustrations Area and click on the Clip Art button

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 26 24 11 This section specifies the furnishing, installation, and connection of the distribution switchboards. 1.2 RELATED WORK: A. Section 13 05 41, SEISMIC RESTRAINT

More information

VisionTouch 5 Software

VisionTouch 5 Software User Manual VisionTouch 5 Software Greengate Contents Contents Description General Information.... 3 Hardware and Software Requirements.... 3 Hardware Requirements.... 3 Software Requirements... 3 VisionTouch

More information

From houses to high-rises

From houses to high-rises ndustrial Solutions rom houses to high-rises Residential products and solutions More choices. exclusive options. continues to provide products and solutions for your residential installations that are

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

Section 9 TVSS. Contents

Section 9 TVSS. Contents Section Contents TPS General Information -2 Internal Equipment Mounted Unit Selection TPS 1, TPS 5, TPS 6-3 External or Remote Mounted Unit Selection TPS and TPS 10 TPS 11 and TPS 12-4 -5 - Transient Voltage

More information

Microsoft Office Word 2013

Microsoft Office Word 2013 Microsoft Office Word 2013 Working with Graphics University Information Technology Services Training, Outreach & Learning Technologies Copyright 2014 KSU Department of University Information Technology

More information

Blueprint Drawings & Wiring Diagrams. for branch circuits

Blueprint Drawings & Wiring Diagrams. for branch circuits Blueprint Drawings & Wiring Diagrams for branch circuits Blueprint Symbols Wiring Diagram Symbols 2 Table of Contents Single Pole Switching p. 5-11 Three-way Switching p. 12-18 Four-way Switching p.19-25

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 16420 - ELECTRICAL EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

Microsoft Office Word 2016 for Windows

Microsoft Office Word 2016 for Windows Microsoft Office Word 2016 for Windows Working with Graphics University Information Technology Services Learning Technologies, Training & Audiovisual Outreach Copyright 2016 KSU Division of University

More information

Create a unit using United Streaming and PowerPoint. Materials: Microsoft PowerPoint, Internet access, United Streaming account

Create a unit using United Streaming and PowerPoint. Materials: Microsoft PowerPoint, Internet access, United Streaming account Create a unit using United Streaming and PowerPoint Materials: Microsoft PowerPoint, Internet access, United Streaming account Find United Streaming Clips: 1. Decide on a topic for your unit. 2. Search

More information

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1 Residential 1-Line 2017 Multifamily Instructions APPROVED User s Manual Copyright 2016 Durand & Associates Page 1 Using Residential 1-Line 2017 with Excel Excel 1997-2003 This product was designed with

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

Geography 281 Mapmaking with GIS Project One: Exploring the ArcMap Environment

Geography 281 Mapmaking with GIS Project One: Exploring the ArcMap Environment Geography 281 Mapmaking with GIS Project One: Exploring the ArcMap Environment This activity is designed to introduce you to the Geography Lab and to the ArcMap software within the lab environment. Before

More information

Microsoft Excel 2007 Lesson 7: Charts and Comments

Microsoft Excel 2007 Lesson 7: Charts and Comments Microsoft Excel 2007 Lesson 7: Charts and Comments Open Example.xlsx if it is not already open. Click on the Example 3 tab to see the worksheet for this lesson. This is essentially the same worksheet that

More information

Comfort Optimizer Installation Instructions

Comfort Optimizer Installation Instructions Congratulations on choosing the best all around load calculation program available. Along with this instruction manual should be the installation CD. Before we can install the Comfort Optimizer, we have

More information

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285. SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

Eaton s SPD Series for integration into electrical distribution equipment

Eaton s SPD Series for integration into electrical distribution equipment Technical Data TD01006E Supersedes August 2009 Eaton s SPD Series for integration into electrical distribution equipment Contents Description Page Introduction....2 Applications....2 Features....2 Standards

More information

Internal Modular SPDs

Internal Modular SPDs Internal Modular SPDs Square D Internally Mounted Protective Devices Square D TM brand logic TM internal modular Protective Devices (SPDs) deliver specification grade performance for service entrance or

More information

Microsoft PowerPoint 2016 Part 2: Notes, Links, & Graphics. Choosing a Design. Format Background

Microsoft PowerPoint 2016 Part 2: Notes, Links, & Graphics. Choosing a Design. Format Background Microsoft PowerPoint 2016 Part 2: Notes, Links, & Graphics Choosing a Design Open PowerPoint. Click on Blank Presentation. Click on the Design tab. Click on the design tab of your choice. In part one we

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

Lesson 4 - Creating a Text Document Using WordPad

Lesson 4 - Creating a Text Document Using WordPad Lesson 4 - Creating a Text Document Using WordPad OBJECTIVES: To learn the basics of word processing programs and to create a document in WordPad from Microsoft Windows. A word processing program is the

More information

Geography 281 Mapmaking with GIS Project One: Exploring the ArcMap Environment

Geography 281 Mapmaking with GIS Project One: Exploring the ArcMap Environment Geography 281 Mapmaking with GIS Project One: Exploring the ArcMap Environment This activity is designed to introduce you to the Geography Lab and to the ArcMap software within the lab environment. Please

More information

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

Model# CKM18 Model# CKM36 Model# CKM48 WARNING Installation Instructions Model# CKM18 Model# CKM36 Model# CKM48 WARNING HAZARDOUS VOLTAGES. DISCONNECT FROM SUPPLY BEFORE REMOVING COVERS. NO USER SERVICEABLE PARTS INSIDE. SERVICE BY QUALIFIED PERSONNEL

More information

Learning Word The ABCs of Microsoft Word. 8/19/2015 The Computor Tutor 1

Learning Word The ABCs of Microsoft Word. 8/19/2015 The Computor Tutor 1 Learning Word 2013 The ABCs of Microsoft Word 8/19/2015 The Computor Tutor 1 The Program Open Word Margins are preset to Normal, 1 inch for Top, Bottom, Right & Left; change by clicking on Page Layout

More information

Select the options to assess for this credit. Only one option can be selected if the rating system is set to Healthcare.

Select the options to assess for this credit. Only one option can be selected if the rating system is set to Healthcare. Surrounding Density and Diverse Uses LT Surrounding Density and Diverse Uses Select options to assess: Select the options to assess for this credit. Only one option can be selected if the rating system

More information

Quick & Simple Imaging. User Guide

Quick & Simple Imaging. User Guide Quick & Simple Imaging User Guide The Quick & Simple Imaging software package provides the user with a quick and simple way to search and find their documents, then view, print, add notes, or even e- mail

More information

Word 2013 Quick Start Guide

Word 2013 Quick Start Guide Getting Started File Tab: Click to access actions like Print, Save As, and Word Options. Ribbon: Logically organize actions onto Tabs, Groups, and Buttons to facilitate finding commands. Active Document

More information

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION ( ) LIGHTING CONTROL PANELBOARD (26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting

More information

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices Table of Contents Section (SPDs) Commercial Applications EMA/EBA SPDs, pages -2, -3, & -4 Externally Mounted External Modular SPDs EMA SPDs -2 External Modular L-L Enhanced SPDs -3 External Brick Assembly

More information

Instruction Manual: IM E

Instruction Manual: IM E Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering

More information

Budget Exercise for Intermediate Excel

Budget Exercise for Intermediate Excel Budget Exercise for Intermediate Excel Follow the directions below to create a 12 month budget exercise. Read through each individual direction before performing it, like you are following recipe instructions.

More information

Basic Modeling 1 Tekla Structures 12.0 Basic Training September 19, 2006

Basic Modeling 1 Tekla Structures 12.0 Basic Training September 19, 2006 Tekla Structures 12.0 Basic Training September 19, 2006 Copyright 2006 Tekla Corporation Contents Contents 3 1 5 1.1 Start Tekla Structures 6 1.2 Create a New Model BasicModel1 7 1.3 Create Grids 10 1.4

More information

Basic Tahoma Multiviewer Design with APANTAC's Director Software

Basic Tahoma Multiviewer Design with APANTAC's Director Software APANTAC How To Article: HT_Tah_Dsgn Basic Tahoma Multiviewer Design with APANTAC's Director Software Applicable to: Tahoma Multiviewers, APANTAC Director Software INTRODUCTION In this document we hope

More information

Working with Census Data Excel 2013

Working with Census Data Excel 2013 Working with Census Data Excel 2013 Preparing the File If you see a lot of little green triangles next to the numbers, there is an error or warning that Excel is trying to call to your attention. In my

More information

Week 5 Creating a Calendar. About Tables. Making a Calendar From a Table Template. Week 5 Word 2010

Week 5 Creating a Calendar. About Tables. Making a Calendar From a Table Template. Week 5 Word 2010 Week 5 Creating a Calendar About Tables Tables are a good way to organize information. They can consist of only a few cells, or many cells that cover several pages. You can arrange boxes or cells vertically

More information

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM> SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual 400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual IO-70104 Rev 1, 1/2014 EMERSON NETWORK POWER SURGE PROTECTIVE DEVICE

More information

Part 2 Add Frame, Arrow, Painted Text.

Part 2 Add Frame, Arrow, Painted Text. Part 2 Add Frame, Arrow, Painted Text. You can use the same Picture on PicPick, or add a new one as I showed you in Step 2 - Part 1. As I mentioned before in Step 2 - Part 1, if you don't have PicPick,

More information

cmt Quick Start Guide

cmt Quick Start Guide cmt Quick Start Guide Your Industrial Control Solutions Source www.maplesystems.com For use with the following: cmt-svr cmt-d090 Maple Systems, Inc. 808 134 th St. SW, Suite 120, Everett, WA 98204 425.745.3229

More information

Adjust model for 3D Printing. Direct modeling tools 13,0600,1489,1616(SP6)

Adjust model for 3D Printing. Direct modeling tools 13,0600,1489,1616(SP6) Adjust model for 3D Printing Direct modeling tools 13,0600,1489,1616(SP6) Sometimes, the model needs to be prepared or adapted for printing. Adding material, change of a draft angles are an example. In

More information