NEMA Motor Control Table of Contents

Size: px
Start display at page:

Download "NEMA Motor Control Table of Contents"

Transcription

1 NEM Motor Control Table of Contents Definite Purpose Contactors Page - Bul Page - Vacuum Contactors Page - Bul. 0C... Page - Bul Page - Bul. 0C... Page - Bul Web Bul. 0V... Web NEM C Contactors and Starters Page - Bul. 00 Top Wiring For Motor Loads... Page - Bul. 00F Feed-Through Wiring For Motor Loads... Page - Bul. 0 Full Voltage Reversing... Page - Bul. 0 Full Voltage Non- Reversing Starters... Page - Bul. 0 Full Voltage Multi-Speed Starters... Page - Bul Page - NEM Combination Contactors, Starters, and Pump Control Panels Page - Bul. 0 Combination Contactor Disconnect Type... Page - Bul. 0 Combination Contactor Circuit Breaker Type... Page - Bul. 0 Reversing Disconnect Type... Page - Bul. 0 Reversing Circuit Breaker Type... Page - Bul. Non-Reversing Disconnect Type... Page - Bul. H Horizontal Mounting Disconnect Type... Page -0 Bul. M Non-Reversing Disconnect Type with Extra Panel Space... Page - Bul. V Non-Reversing Vacuum Disconnect Type... Page - Bul. Non-Reversing Circuit Breaker Type... Page - Information for this product line is available on the Industrial Controls Catalog website: NEM Combination Contactors, Starters, and Pump Control Panels, Cont'd. Bul. H Horizontal Mounting Disconnect Type... Page - Bul. M Non-Reversing Circuit Breaker Type with Extra Panel Space... Page - Bul. V Non-Reversing Vacuum Disconnect Type... Page - Bul. Multi-Speed Combination Starter Disconnect Type... Page -0 Bul. Multi-Speed Combination Starter Circuit Breaker Type... Page - Bul. X Pump Control Disconnect Type... Page - Bul. X Pump Control Circuit Breaker Type... Page -00 Bul. Oil Well Pump Control... Page -0 NEM Reduced Voltage Starters, Combination Starters, and Pump Panels Page -0 Bul. 0 Part Winding Starter... Page -0 Bul. & Part Winding Combination Starter and Pump Control Panel Disconnect Type... Page -0 Bul. & Part Winding Combination Starter and Pump Control Panel Circuit Breaker Type.. Page -0 Bul. 0 Wye-Delta Starter... Page -0 Bul. & Wye-Delta Combination Starter and Pump Control Panel Disconnect Type... Page - Bul. & Wye-Delta Combination Starter and Pump Control Panel Circuit Breaker Type.. Page - Bul. 0 utotransformer Starter... Page - Bul. & utotransformer Combination Starter and Pump Control Panel Disconnect Type... Page - Bul. & utotransformer Combination Starter and Pump Control Panel Circuit Breaker Type.. Page - Bul. 00 Line Modifications and ccessories... Page - Bul. 00 Line Specifications... Page - Bul. 00 Line pproximate Dimensions... Page - Bul. 00 Line Renewal Parts... Page - Bul. 00 Line Overload Relay Code Selection... Page - 0 -

2 NEM Motor Control Table of Contents, Continued Overload Relays Page -0 Bul. E Plus... Page - Bul. E and E Plus... Page - Bul. Manual Reset Overload Relays... Page - Heater Element Selection... Page - Circuit Breaker Mechanisms Page - Bul. V Variable-Depth Flange- Mounted Circuit Breakers... Page - Bul. D Fixed-Depth Flange- Mounted Circuit Breakers... Page - NEM Manual Starting Switches Page -0 Bul. 00 Single-Phase... Page -0 Bul. 0 Single- and Three-Phase... Page -0 Bul. 0U with Undervoltage Protection... Page -0 Disconnect Switches Page - Bul. V Variable-Depth Flange- Mounted Disconnect Switches... Page - Bul. C Cable-Operated Disconnect Switches... Page -0 Bul. F Fixed-Depth Flange- Mounted Disconnect Switches... Page - Bul. R Variable-Depth Door- Mounted Rotary Disconnect Switches... Web Operating Mechanisms Bul. V Variable-Depth Flange- Mounted Remote or Dual Type Operating Mechanisms... Page - Bul. M Fixed-Depth Flange- Mounted Operating Mechanisms... Page - Safety Switches Page - Bul. G Enclosed Disconnect Safety Switches... Page - Bul. H Safety Switches... Page - Bul. Line ccessories... Page - Bul. Line Specifications... Page - Bul. Line pproximate Dimensions... Page - Fuse Blocks Bul. Fuse Blocks... Web Definite-Purpose Style Enclosures Page - Bul. General-Purpose Enclosure... Page - Bul. Junction Box... Page - Bul.. mm Push Button Enclosures... Page - Bul. 00H 0. mm Push Button Enclosures... Page - 0 Information for this product line is available on the Industrial Controls Catalog website: -

3 Bulletin 00 Definite Purpose Contactors Product Overview Definite-Purpose Contactors Features Bulletin 00 Compact size Feed-through wiring Class B (0 ºC) coil insulation Double E magnet assembly Snap-on auxiliary contacts Combination pressure and quick connect terminals bility to accept ring terminals Double-break contacts No. of Poles & FL Rating 0/ / 0 rc Cover Optional Standard Standard Standard Termination Certifications Product Selection / in. QC, #0 screw Box lugs optional CS Certified (File No. LR) UL Recognized (File No. E, Guide No. NLDX) CE Marked SEMKO Certified / in. QC, #0 screw Box lugs optional ( 0 ) Coil screws optional CS Certified (File No. LR) UL Recognized (File No. E, Guide No. NLDX) CE Marked SEMKO Certified Box lug, standard Option available to accept ring terminals CS Certified (File No. LR) UL Recognized (File No. E, Guide No. NLDX) CE Marked SEMKO Certified / in. QC, #0 screw ( 0 ) Box lugs (0 ) Coil screws optional CS Certified (File No. LR) UL Recognized (File No. E, Guide No. NLDX) CE Marked SEMKO Certified Page - Page - Page - Page - 0 -

4 Bulletin 00 Definite Purpose Contactors Overview/Catalog Number Explanation -pole Bulletin 00 vailable in the following ranges: -Pole: 0/ 0, 00V max. -Pole: 0/ 0, 00V max. -Pole: 0/ 0, 00V max. -Pole: 0/ 0, 00V max. The llen-bradley Bulletin 00 Definite Purpose contactors are specifically designed for applications such as air-conditioning, refrigeration, resistive heating, data processing and food service equipment, pumps, and compressors. Box lugs are standard on 0 contactors and larger. maximum of two auxiliary contact blocks (one on each side, four contacts max.) can be field installed. Table of Contents ccessories Specifications... - pproximate Dimensions - Standards Compliance UL 0 CS C. No. EN/IEC 0-- Meets the material restrictions of the EU RoHS Directive -pole Catalog Number Explanation Certifications UL Recognized (File No. E, Guide No. NLDX) CS Certified (File No. LR) CE Marked SEMKO Certified 00 DP0 N a b c d e 0 Current Rating Code Full Load mps [] DP 0/ DP0 0 DP0 0 DP0 0 DP0 0 DP DP0 0 Enclosure Code Code Enclosure N No enclosure/no exceptions Nominal Coil Voltage Code 0/0 Hz Frequency J D 0 0/0 F LF B 0 a b c Code d Number of Poles Description pole poles poles poles Code B D E K R S T U X e Modifications Description Box lug with DP or DP0 in nd position 00-DR factory attached to DP (0/ 0 ) poles with -pole base screw coil terminal with DP, DP0, or DP0 in nd position Ring terminal for DP0 DP0 0 SEMS terminal Coil terminals down Coil terminals on load side (T/, T/, T/) without quick connect line/load terminals Without quick connect terminals on line and load Code B Code B Code B e (cont'd) Modifications -Pole 0/, 0, and 0 only Description uxiliary contact N.O./ N.C. with Quick Connect uxiliary contact SPDT with QC uxiliary contact SPDT with QC -Pole 0 0 only Description uxiliary contact N.O./ N.C. with QC uxiliary contact SPDT with QC -Pole 0/, 0, and 0 only Description uxiliary contact N.O./ N.C. with QC uxiliary contact SPDT with QC -

5 Bulletin 00 Definite Purpose Contactors Quick Selection Table Contactors Number of Poles FL Rating rc Cover Standard Termination Certifications Page Number 0 0 Optional #0 screw with / in. QC #0 screw with / in. QC Standard - 0 Box lug (option available to accept ring terminals) 0, 0 Standard, 0 Standard Box lug (option available to accept ring terminals) #0 screw with / in. QC 0 Standard Box lug (option available to accept ring terminals) - 0 -

6 Bulletin 00 Definite Purpose Contactors Product Selection Προδυχτ Σελεχτιον 0/ 0 FL - & -Pole -Pole Contactor with Shunt -Pole Contactor with Optional rc Cover 0 Full Load mps Coil Voltage Code for - and -Pole Contactors The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00-DPN becomes 00-DPNJ. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] 0 0/0 0 Code J D F B Coil Technical Data rc Cover Number of Poles 0/ 0/ 0 0 Maximum Continuous mpere Rating [] Maximum Horsepower Tungsten Lamp Loads Ballast Lighting Load Line Voltage Locked Rotor mps Resistive mps Rating Voltage Single Phase 0/ / / Coil terminal screws are not available on - and -pole contactors. Max. 0V line V load Fluorescent / & 0 One-Pole Contactors 0/ & 0 Two-Pole Contactors Nominal Coil Voltage 0 0/ /0 0 Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush V 0 Hz Hz Nominal Sealed V 0 Hz 0 Hz..... Nominal DC Resistance (Ω) Description 0/ & 0 -Pole 00-C 0/ & 0 -Pole 00-C 0 0/ DPN 00-DPN 00-DP0N 00-DP0N -

7 Bulletin 00 Definite Purpose Contactors Product Selection, Continued 0/ 0 FL -Pole Full Load mps Number of Poles Maximum Continuous mpere Rating [] Tungsten Lamp Loads 0/ FL Contactor -Pole with optional Coil Terminal Screws Locked Resistive Maximum Horsepower Ballast Lighting Load Line Voltage Rotor mps mps Rating Voltage Single Phase Three Phase 0/0 0/ / / /0. 0/ /0 00/0 0 0/ /0 00/0 0 0/ DPN 00-DP0N 00-DP0N To use ring terminals on 0 FL and larger power connections add the suffix R to the catalog number. Example: 00-DP0N becomes 00-DP0N -R. Max. 0V line V load Fluorescent Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00-DPN becomes 00-DPNJ. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] 0 0/0 0 Code J D F LF B Coil Technical Data Nominal Coil Voltage 0 0/0 0 Maximum Pickup Volts 0 Drop-Out Volts Range Nominal Inrush V 0 Hz 0 Hz Nominal Sealed V 0 Hz Hz Nominal DC Resistance (Ohms). 0 uxiliary Contacts Description N.O./ N.C. w/qcs 00-B SPDT w/qcs 00- SPDT w/qcs 00- Contact rating single-circuit N.O. or N.C.: mperes [V] Break Make 0. Continuous Contact rating SPDT: 0, / Hp, or 0V C; /, V DC; /, 0V DC; 0V C on lamp load 0 -

8 Bulletin 00 Definite Purpose Contactors Product Selection, Continued 0 0 FL -Pole 0 0 & 0 FL -Pole & 0 FL -Pole Maximum Continuous mpere Rating [] Locked Resistive Maximum Horsepower Full Load Number Tungsten Lamp Ballast Lighting Line Rotor mps mps of Poles Loads Load Voltage mps Rating Voltage Single Phase Three Phase 0/ / / / /0 00/ /0. 00/ DP0N 00-DP0N 00-DPN 00-DP0N To use ring terminals on 0 FL and larger power connections add the suffix R to the catalog number. Example: 00-DP0N becomes 00-DP0N -R. Max. 0V line V load Fluorescent Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00-DP0N becomes 00-DP0NJ. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] 0 0/0 0 Code J D F B Coil Technical Data Nominal Coil Voltage 0 0/0 0 0 & 0 & 0 0 & 0 & 0 0 & 0 & 0 0 & 0 & 0 0 & 0 & 0 Maximum Pickup Volts 0 Drop-Out Volts Range Nominal Inrush V 0 Hz Hz Nominal Sealed V 0 Hz Hz Nominal DC Resistance (Ohms) uxiliary Contacts Description N.O./ N.C. w/qcs 00-B SPDT w/qcs 00- Contact rating single-circuit N.O. or N.C.: [V] Contact rating SPDT: 0, / Hp, or 0V C; Break /, V DC; mperes Make 0. /, 0V DC; Continuous V C on lamp load

9 Bulletin 00 Definite Purpose Contactors Product Selection, Continued 0/ 0 FL -Pole Full Load mps Number of Poles Maximum Continuous mpere Rating [] Tungsten Lamp Loads 0/ 0 0 Max. 0V line V load Fluorescent -Pole Locked Resistive Maximum Horsepower Ballast Lighting Load Line Voltage Rotor mps mps Rating Voltage Single Phase Three Phase 0/0 0/ / / /0. 0/ /0 00/0 0 0/ /0 00/0 0 0/ DPN 00-DP0N 00-DP0N Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00-DPN becomes 00-DPNJ. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] 0 0/0 0 Code J D F LF B Coil Technical Data Nominal Coil Voltage 0 0/0 0 Maximum Pickup Volts 0 Drop-Out Volts Range Nominal Inrush V 0 Hz 0 Hz Nominal Sealed V 0 Hz 0 Hz Nominal DC Resistance (Ohms) uxiliary Contacts Description N.O./ N.C. w/qcs 00-B SPDT w/qcs 00- Contact rating for single circuit N.O. or N.C.: mperes Contact rating SPDT: 0, / Hp, or 0V C; /, V DC; /, 0V DC; 0V C on Lamp Load [V] Break Make 0. Continuous

10 Bulletin 00 Definite Purpose Contactors ccessories/modifications Αχχεσσοριεσ ccessories Description For Use With Mechanical Interlock Kit 0/ 0 -pole 00-MK DIN Rail dapter 0/ 0 - -pole 00-DR Modifications Description Box lug with DP or DP0 in second position Molded coil (not available with or in fifth position) Factory-installed DIN Rail adapter (0 0 ) -pole with -pole base # screw coil terminal with DP, DP0, or DP0 in second position (- & -pole only) Ring terminal for DP0 DP0 #0 SEMS terminals with DP, DP0, or DP0 in second position Coil terminals down Coil terminals on load side (T/, T/, T/) without quick connect (QC) line/load terminals -pole 0/, 0, and 0 only. -pole 0 0 only. Without QC terminals on line and load Suffix Code uxiliary contact N.O./ N.C. with QC B uxiliary contact SPDT with QC uxiliary contact SPDT with QC uxiliary contact N.O./ N.C. with QC B uxiliary contact SPDT with QC B C D E K R S T U X 0-0

11 Bulletin 00 Definite Purpose Contactors Specifications Σπεχιφιχατιονσ 0/ 0 FL - & -Pole Line and Load Terminals #0 screw Wire Size Min. Max. Mechanical Life Electrical Life Recommended Tightening Torque Quick Connects 0/ 0 FL -Pole 0 0 FL -Pole 0 FL -Pole Line and Load Terminals Box lug Line and Load Terminals Wire Size Min. Max. Mechanical Life Electrical Life Recommended Tightening Torque Quick Connects rc Cover Insulation System Temperature Range Mounting Position Weight Power terminals Coil terminals rc Cover Insulation System Temperature Range Mounting Vertical Position Horizontal -Pole Weight -Pole WG (stranding must be split for # wire) operations operations lb in Dual 0.0 QC () -Pole: Quad 0.0 QC -Pole: Dual or Quad 0.0 QC Optional 0 C Class B -0 C (-0 0 F) ll positions Base down only 0. lb 0. lb WG operations operations 0 lb in Power Dual 0.0 QC () terminals Coil terminals # screw & 0.0 QC () Standard 0 C Class B -0 C (-0 0 F) Vertical ll positions Horizontal Base down only lb 0/ 0 FL -Pole Line and Load Terminals Wire Size Min. Max. Mechanical Life Electrical Life Recommended Tightening Torque Quick Connects rc Cover Insulation System Temperature Range Mounting Position Weight #0 screw Box lug Line and Load Terminals Wire Size Min. Max. Mechanical Life Electical Life Recommended Tightening Torque Quick Connects #0 screw Box Lug #0 screw Box lug Power Terminals Coil terminals rc Cover Insulation System Temperature Range Mounting Vertical Position Horizontal Weight Wire Size Min. Max. Mechanical Life Electrical Life Recommended Tightening Torque Quick Connects rc Cover Insulation System Temperature Range Mounting Position Weight #0 screw or box lug WG (stranding must be split for # wire) WG operations operations #0 lb in screw Box lug 0 lb in Power Dual 0.0 QC terminals Coil terminals Dual 0.0 QC () Standard 0 C Class B -0 C (-0 0 F) Vertical ll positions Horizontal Base down only. lb #0 screw or box lug WG (stranding must be split for # wire) WG operations operations lb in. 0 lb in Dual 0.0 QC () Quad 0.0 QC Standard 0 C Class B -0 C (-0 0 F) ll positions Base down only lb Box lug /0 WG operations operations 0 lb in Power Dual 0.0 QC terminals Coil terminals # screw & 0.0 QC () Standard 0 C Class B -0 C (-0 0 F) Vertical ll Positions Horizontal Base down only lb 0 -

12 Bulletin 00 Definite Purpose Contactors pproximate Dimensions Αππροξιματε Διμενσιονσ 0/ 0 FL - & -Pole Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. 0/ 0 FL -Pole 0 -

13 Bulletin 00 Definite Purpose Contactors pproximate Dimensions, Continued Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. 0 & 0 FL -Pole & 0 FL -Pole 0 -

14 Bulletin 00 Definite Purpose Contactors pproximate Dimensions, Continued Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. 0 FL -Pole DIN Rail daptors.. Terminations 0 Standard on DP and DP0 #0 combination Phillips, slotted & / hex head # washer Special on DP, DP0, and DP0 #0 Sems screw with pressure plate 0 FL Lug WG 0 and 0 FL Lug WG and 0 FL Lug /0 WG -

15 Bulletin 0C, 0, 0C Vacuum Contactors Product Overview Vacuum Contactors and Starters Features Typical Industry pplications Bulletin 0C 0 0C Horsepower Ratings Motor Voltage Capacitor Switching Transformer Primary Switching Continuous Current Rating [] Certifications Up to 00V C maximum Space-saving design Contacts sealed from harsh contamination improved performance Improved arc extinguishing above 00V reduced contact erosion for higher voltages Minimal mechanical movement minimizes downtime DC magnet assembly reduces power consumption Mining and metals Process equipment Chemical processing Conveyors Pumps Petroleum Hoists Mining equipment 00 00V 0 00 Hp 0 00V 0 kvr 0 00V 0 kv Up to 00V C maximum Effective arc extinguishing above 00V Compact size Contacts sealed from harsh contamination improved performance Minimal mechanical movement minimizes downtime DC magnet assembly reduces power consumption Mining and metals Process equipment Chemical processing Conveyors Pumps Petroleum Hoists Mining equipment Other harsh environments where voltages above 00V are used 00 00V 0 00 Hp 00V C maximum Effective arc extinguishing above 00V Contacts sealed from harsh contamination improved performance Minimal mechanical movement minimizes downtime DC magnet assembly reduces power consumption Pharmaceutical industry Petroleum industry Cement and metal processing Pulp and paper industries Cranes and hoists Chemical Processing Pumps Mining Foundries 00 00V 0 00 Hp culus Listed (File No. E Guide No. NLDX / NLDX) culus Listed (File No. E Guide No. NLDX / NLDX) culus Listed (File No. E Guide No. NLDX / NLDX) Product Selection Page - Page - Page - 0 -

16 Bulletin 0C Non-Reversing Vacuum Contactors Overview/Catalog Number Explanation/Product Selection 0 Bulletin 0C 00V C maximum Current ratings: 00, 00, and 00 Visual ON/OFF indicator Line and load terminals up front for ease of wiring Typical industry applications include: Foundries Pumps Chemical processing Cranes Conveyors Mining equipment The Bulletin 0C open type contactor is designed for use up to 00V. Vacuum contactors are particularly well-suited for mining, pumping, and other applications where voltages above 00V are used. The Bulletin 0C line uses vacuum bottles to enclose the power-switching contacts within the contactor. The use of vacuum technology results in particularly effective arc extinguishing above 00V and results in a very compact, long-lasting contactor. Configuration of a Basic Vacuum Contactor The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. 0C B O D Continuous Current Rating [] Code Description B 00 C 00 D 00 Code O Product Selection -Phase, 00V Maximum, 0 Hz a b NEM Enclosure Type Type Open type no enclosure a b c d c Control Voltage Code Voltage Frequency 0 0V C 0 Hz B 0 0V C 0 Hz D 0V C 0 Hz N 0 V C 0 Hz G V DC H 0V DC Table of Contents Product Selection... this page ccessories... - Specifications pproximate Dimensions Standards Compliance UL 0 CS. No. EN0- (000V) Certifications culus Listed (File No. E, Guide No. NLDX, NLDX) Control Voltage Code The cat. no. is incomplete. To complete the cat. no., select a control voltage code from the table below and insert into the cat. no. Example: 0C-BO becomes 0C-BOD. d Options Code Description -pole contactor Capacitor Switching [kvr] Transformer Primary Switching [kv] Continuous Current 0V 0V V 000V 00V 0V 0V V 000V 00V Rating [] C-BO C-CO C-DO Motor Switching Ratings 00V / 0V 0V / 0V 0V / V 0V / 0V 0V / 00V 000V 00V [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] C-BO C-CO C-DO [V] C 0/0 Hz D N B DC G H Inrush current should be less than 000% of IEC C operational current. For use on transformers having an inrush not more than 0 times the rated full load current irrespective of secondary load. Ratings do not apply to transformers used in resistive welder service. Terminal lugs not included see ccessories (page -). -

17 Bulletin 0 NEM Non-Reversing Vacuum Starter Overview/Catalog Number Explanation/Product Selection Bulletin 0 00V C maximum Current ratings: 00, 00, and 00 Time-proven eutectic or solid-state overload protection with current transformers E Plus overload relay with wide : adjustment range Line and load terminals up front for ease of wiring Visual ON/OFF indicator Snap-on side-mount auxiliary contacts Configuration of a Basic Vacuum Starter The information below is for reference purposes. Not all combinations will produce a valid Refer to the tables on the following pages for product selection. 0 B O D EEJ Continuous Current Rating [] Code Description B 00 C 00 D 00 Code O Product Selection -Phase, 00 00V, 0 Hz a b NEM Enclosure Type Type Open type no enclosure The Bulletin 0 open-type starter is designed for use up to 00V. Vacuum starters are particularly well-suited in mining, pumping, and other harsh environments where voltages above 00V are used. The Bulletin 0 line uses vacuum bottles to enclose the power-switching contacts within the starter. The use of vacuum technology results in particularly effective arc extinguishing above 00V and results in a very compact, long-lasting starter. a b c d c Control Voltage Code Voltage Frequency 0 0V C 0 Hz B 0 0V C 0 Hz D 0V C 0 Hz G V DC H 0V DC N 0 V C 0 Hz Code Blank Table of Contents Product Selection... this page ccessories... - Specifications pproximate Dimensions... - Standards Compliance UL 0 CS. No. EN0- (000V) Certifications culus Listed (File No. E, Guide No. NLDX, NLDX) d Overload Relay Code Current Description Starter Size Range [] Eutectic alloy Heater elements 00, 00, 00 EEJ EEW E Plus solid-state EEM Motor Switching Ratings 00 0V 0 0V 0 0V 0 00V 000V 00V Continuous [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] Current Rating [] BO CO DO - Control Voltage Code The cat. no. is incomplete. To complete the cat. no., select a control voltage code from the table below and insert into the cat. no. Example: 0-BO becomes 0-BOD. [V] C 0/0 Hz D N B Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page -0 to complete the cat. no. Example: 0-BOD- becomes 0-BOD-EEJ. 0 -

18 Bulletin 0C Reversing Vacuum Contactors Overview/Catalog Number Explanation/Product Selection 0 Bulletin 0C 00V C maximum Current ratings: 00, 00, and 00 Visual ON/OFF indicator Line and load terminals up front for ease of wiring Typical industry applications include: Mining equipment Conveyors Foundries Cranes and hoists Chemical processing Pumps Configuration of a Basic Vacuum Contactor The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. 0C B O D Continuous Current Rating [] Code Description B 00 C 00 D 00 Code O a b NEM Enclosure Type Type Open type No enclosure Product Selection -Phase, 00V Maximum, 0 Hz Control Voltage Code The Bulletin 0C reversing contactor consists of two Bulletin 0C vacuum contactors mounted vertically on a common base. Contactors are mechanically and electrically interlocked to avoid both contactors being closed simultaneously. Vacuum contactors are particularly wellsuited for mining, pumping, and other applications where voltages above 00V are used. a b c d c Control Voltage Code Voltage Frequency 0 0V C 0 Hz D 0V C 0 Hz G V DC Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E; Guide No. NLDX, NLDX) Options Code Description -pole contactor only Motor Switching Ratings 0 0V 0 0V 0 V 0 0V 0 00V 000V 00V Table of Contents Product Selection... this page ccessories... - Specifications pproximate Dimensions... - The cat. no. is incomplete. To complete the cat. no., select a control voltage code from the table below and insert into the cat. no. Example: 0C-BO becomes 0C-BOD. [V] 0 0 C 0/0 Hz D DC G Inrush current should be less than 000% of IEC C operational current. For use on transformers having an inrush not more than 0 times the rated full load current irrespective of secondary load. Ratings do not apply to transformers used in resistive welder service. Terminal lugs not included see ccessories (page -). d Cont. Current Rating [] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] C-BO C-CO C-DO -

19 Bulletin 0C, 0, 0C Vacuum Contactors ccessories ccessories uxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (00 rating) as standard. dditional auxiliary contacts, two normally open and two normally closed, can be added in the field. Lug Kit ( per kit) Description uxiliary Contact 00V) uxiliary Contact (0 V DC) C-N C-N Continuous Current Rating [] Wire Size Control Module Side-mounted module for DC input voltage Continuous Current Rating [] Input Voltage 00/00/00 Control Pak Side-mounted module for DC coil power V DC 0V DC C-N C-N Continuous Current Rating [] Input Voltage 00 00/00 0/0V C 0C-CPD 0/0V C 0C-CP 0/V C 0C-CPN 0/0V C 0C-CPB 0/0V C 0C-CPD 0/0V C 0C-CP 0/V C 0C-CPN 0/0V C 0C-CPB Coil Kit Contains DC coil mounted in the sheet metal frame assembly that attaches to the contactor mounting plate Continuous Current Rating [] Input Voltage Control Pak Voltage /0 0 MCM C-LK 00 () # 00 MCM C-LK 00 () # 00 MCM C-LK Vacuum Interrupter Phase ssembly Kit Replacement for one vacuum interrupter phase 0V DC 0/0V C 0C-PKD 0/0V C 0C-PK 0/V C 0C-PKN 0/0V C 0C-PKB V DC 0C-PKG 0V DC 0C-PKH 0V DC 0/0V C 0C-PKD 0/0V C 0C-PK 0/V C 0C-PKN 0/0V C 0C-PKB V DC 0C-PKG 0V DC 0C-PKH 0V DC Current Rating of Interrupter [] 0/0V C 0C-PKD 0/0V C 0C-PK 0/V C 0C-PKN 0/0V C 0C-PKB V DC 0C-PKG 0V DC 0C-PKH 00 Vacuum Interrupter Phase ssembly 0C-VB 00 Vacuum Interrupter Phase ssembly 0C-VB 00 Vacuum Interrupter Phase ssembly 0C-VB 0 -

20 Bulletin 0C, 0, 0C Vacuum Contactors Specifications/pproximate Dimensions Specifications Standards pproximate Dimensions EN 0-000V UL 0 CS. 00V Power Ratings EN 0-000V UL 0 CS. 00V Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0C (00 ) EN 0-000V UL 0 CS. 00V Insul. & Operating Voltage 00 00V 00 00V 00 00V Rated Fequency 0 00 Hz 0 00 Hz 0 00 Hz Making Current Capacity Breaking Current Capacity Dielectric Strength Kv - Min. Interrupter GP Kv - Min. Interrupter GP Kv - Min. Interrupter GP Interrupting Current (Max.). k. k k Short Circuit Withstand (Max.) 0 k symmetrical 00V C k symmetrical 00V C 0 k symmetrical 00V C Mechanical Life Elect. Life C Duty Switching Frequency (Mechanical) 0C, 0 0C 000/hr (max.)./s (full cycle) 000/hr (max.)./s (full cycle) 000/hr (max.)./s (full cycle) Withstand current for sec [k]..0. Chop Current Max Control Ratings Coil Voltage Operation -% +0% -% +0% -% +0% Inrush Power V 00V 00V 00V Sealed Power V V V V Opening Time [ms] Closing Time [ms] Pick-Up Voltage 0% Cold % Hot 0% Cold % Hot 0% Cold % Hot Drop-Out Voltage 0% or less 0% or less 0% or less pplication Ratings Mounting Installation ll planes ll planes ll planes ltitude 00 ft (000 m) 00 ft (000 m) 00 ft (000 m) mbient Storage - +0 F (- C) - +0 F (- C) - +0 F (- C) Operating Temperature -0 + F (-0 C) -0 + F (-0 C) -0 + F (-0 C) Vibration/Shock 0 Hz- G/0 G 0 Hz- G/0 G 0 Hz- G/0 G 0-0

21 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0C (00 and 00 ) 0. [. mm] 0. [. mm] R 0. [. mm] () Mtg. Holes 0. [. mm] Ø 0. [0. mm] 0. [. mm] 0. [. mm] R 0. [. mm] () Mtg. Holes 0. [. mm] 0. [. mm] 0. [0. mm] 0. [ mm] 0 Ø 0. [0. mm] 0. [. mm] 0. [. mm] -

22 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 (00 ) With E Plus Overload 0 -

23 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 (00 ), Continued With Eutectic Overload 0 -

24 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 (00 ) With E Plus Overload 0 -

25 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 (00 ), Continued With Eutectic Overload 0 -

26 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 (00 ) With E Plus Overload 0 -

27 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 (00 ), Continued With Eutectic Overload 0 -

28 Bulletin 0C, 0, 0C Vacuum Contactors pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0C (00, 00, 00 ) B E C D Contactor Size [] Height. (). () (0) B Width () (0) (0) C Depth. (0).0 ().0 () D Mounting Height (0). () 0. (0) E Mounting Width () () () 0 -

29 Bulletin 00, 00F, 00DC, 0, 0, 0, 00 NEM C Contactors and Starters Product Overview NEM C Contactors Bulletin 00 00F Features Top Wiring for motor loads Feed-through wiring for motor loads NEM Size 00 0 Continuous mpere Rating [] -Phase Power Poles -Phase Power Poles -Phase Power Poles -Phase Power Poles Enclosures (NEM Type) Standards Certifications 0 0 0V (/ Hp) 00 00V (-/ 00 Hp) 00 00V (-/ 00 Hp) 00 00V ( 00 Hp) 0V ( Hp) 00 00V ( 00 Hp), R/, /X,, and NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. BS /. USCG CFR.0 IEEE UL Listed (File No. E; Guide No. NLDX) (File No. E0; Guide No. NPKR) CS Certified (LR) CE Marked (Per EN 0) merican Bureau of Shipping (BS) NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. BS /. USCG CFR.0 IEEE UL Listed (File No. E; Guide No. NLDX) (File No. E0; Guide No. NPKR) CS Certified (LR) CE Marked (Per EN 0) merican Bureau of Shipping (BS) Product Selection Page - Page - Bulletin 00DC Electronic DC Coil Controller Compact size NEM Size 0 Versatility Fully assembled unit or as a retro-fit kit LED status indication LED diagnostics determine if the controller is functioning correctly Low power consumption Draws. watts steady Features state Built-in thermal protection The controller is protected from over temperature Reverse polarity protection Should the wiring be reversed during installation or coil change, no damage will occur 0 NEM Size DC Voltage V 0V Min. DC Inrush Switching Requirement for Logic Control Device culus Listed (File No. E0) Certifications CE mark (per EN 0) n example of a factory-assembled contactor catalog Example number is 00DC-BOVL0. For further details visit the on-line catalog. For Use With Bulletin 00 (Page -0) 0 -

30 Bulletin 00, 00F, 00DC, 0, 0, 0, 00 NEM C Contactors and Starters Product Overview, Continued NEM Starters Bulletin Features Reversing starters are most commonly used for full-voltage starting and reversing of polyphase squirrel-cage motors These starters may be operated by remote control with push buttons, float switches, thermostats, pressure switches, snap switches, limit switches, or any other suitable - or -wire pilot device Multi-speed starters are designed for the control of two-speed squirrel-cage motors of either consequent pole or separate winding types Open Type Bul. 0E, F, G -Phase 00V, -Pole Overload Protection NEM Size Continuous mpere Rating Motor Voltage 00 V (. 00 Hp) 00 V (. 00 Hp) 00 V ( 00 Hp) -Phase V Max. -Pole Overload Protection NEM Size Continuous mpere Rating 0 Motor Voltage 0V (/ Hp) 0V (/ Hp) Enclosure Type, R/, /X,, and, R/, /X,, and, R/, /X,, and Standards Certifications Product Selection NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. BS /. USCG CFR.0 IEEE NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. BS /. USCG CFR.0 UL Listed (File No. E; Guide No. NLDX) CS Certified (File LR ) CE Marked (per EN 0--) merican Bureau of Shipping (BS) Hazardous Location: UL Listed (File No. E0), CS Certified (File No. LR ) NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. BS /. UL Listed (File No. E; Guide No. NLDX) CS Certified (File LR ) Hazardous Location: UL Listed (File No. E0), CS Certified (File No. LR ) Page - Page - Page - 0 Bulletin 00 Features Modular line of NEM contactors Space saving design Electronic & conventional coils DIN Rail mountable Common accessories Guarded terminals NEM Size 0 DIN Rail Mountable Certifications Product Selection culus Listed (File No. E0, Guide No. NLDX, NLDX) CE Marked (per EN0--) Page - Bulletin 00DC Electronic DC Coil Controller Compact size NEM sizes 0 Versatility Fully assembled unit or as a retro-fit kit LED status indication LED diagnostics determine if the controller is functioning correctly Low power consumption Draws. watts steady Features state Built-in thermal protection The controller is protected from over temperature Reverse polarity protection Should the wiring be reversed during installation or coil change, no damage will occur NEM Size 0,, and DC Voltage V 0V Min. DC Inrush Switching Requirement for Logic Control Device Certifications Example Cat. No. For Use With culus Listed (File No. E0, Guide No. NKCR, NKCR) CE mark (per EN 0--) n example of a factory-assembled contactor catalog number is 00DC-BOVL0. For further details visit the on-line catalog. Bulletin 0 (Page -). For Bulletins 0 and 0, consult your local Rockwell utomation sales office or llen-bradley distributor. -0

31 Bulletin 00 NEM C Contactors Top Wiring for Motor Loads Bulletin 00 Top wiring for motor loads Enclosure ratings: NEM Type, R/, /X (stainless steel), glass reinforced polyester and bolted &, and R, & Bulletin 00 C Contactors are available in Top Wiring Construction from NEM Size 00. ll power connections are at the top of the contactors. Bulletin 00 contactors are used for switching C motor loads where overload protection is not required or is provided separately. Table of Contents Product Selection... - ccessories... - Modifications... - Specifications... - Full Load Currents of C Motors... - pproximate Dimensions... - Renewal Parts... - Coil Data... - Size 0, -Pole, Open Type without Enclosure Top Wiring Construction Standards Compliance NEM/EEMC ICS UL 0 CS C. No. BS /. merican Bureau of Shipping Example a UCSG CFR.0 IEEE EN/IEC 0-- CE Marked Bulletin No. Bulletin No. Description 00 Combination Top wired for motor loads 00F Contactor Feed-through wiring contactor for motor loads 00FL Contactor Feed-through lighting contactor, pole maximum 00L Contactor Top wired lighting contactor 0 Starter Reversing 0 Starter Non-reversing 0 Starter Multispeed b NEM Size Code Description 0 B C D E F G H J K T B D 0 a b c d e f c NEM Enclosure Type Code Type Type C Type (stainless steel) E Type & bolted H Type R, & bolted J Type O No enclosure S Type X (non-metallic) Code Voltage B C D 0 0V 0 0V 00V 0V d Nominal Coil Voltage Frequency 0 Hz KN Frequency Code Voltage 0 0 Hz 00V 0 Hz M 00V 0 Hz 0 Hz N 0V 0 Hz 0 Hz P F V 0 Hz Q Certifications CS Certified (LR) UL Listed (File No. E, Guide No. NLDX) Hazardous Location: UL LIsted (File No. E0) CS Certified (LR) 0 0V 0 0V 0 Hz 0 Hz H 00 0V 0 Hz R 0V 0 Hz I V 0 Hz S 0 V 0 Hz J V 0 Hz T 0V 0 Hz K V 0 Hz U V 0 Hz Note: ll enclosed non-combination contactors and starters are supplied with external reset as standard. pplies to contactors only e Number of Poles Code Voltage Description Two Poles 0 Two Poles and () uxiliary Contact (N.O.) Three poles 0 Three Poles and () uxiliary Contact (N.O.) Four Poles 0 Four Poles and () uxiliary Contact (N.O.) Five Poles 0 Five Poles and () uxiliary Contact (N.O.) f Options See catalog for detailed information on options. 0 -

32 Προδυχτ Σελεχτιον Bulletin 00 NEM C Contactors Product Selection Προδυχτ Σελεχτιον Top Wiring For Motor Loads Max. Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Open Type Without Enclosure Without uxiliary Contact With One N.O. uxiliary Contact Type General Purpose Enclosure With One N.O. uxiliary Contact Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight, Corrosion- Resistant Enclosures Stainless Steel NEM Size Continuous mpere Rating [] Motor Voltage V 0V -Phase Power Poles 00V C Maximum 0 Hz 00 / 00-TO 00-TO 0 00-T O 00-O J 0 00-C 0 00-BO 00-BO 0 00-B 0 00-BJ 0 00-BC 0 -/ 00-CO 0 00-C 0 00-CJ 0 00-CC 0 0 -/ 00-DO 0 00-D 0 00-DJ 0 00-DC 0 00-EO 0 00-E 0 00-EJ 0 00-EC FO 0 00-F 0 00-FJ 0 00-FC HO 0 00-H 0 00-HJ 0 00-HC 0 00-JO 0 00-J KO 0 00-K 0 0 NEM Size Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00-O becomes 00-OD. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] C, 0 Hz C, 0 Hz - Continuous mpere Rating [] 00V 0V Hz 0 0 V V 0-0 -Phase Power Poles 00V C Maximum 0 Hz 00 -/ -/ 00-TO 00-TO 0 00-T O 00-O J 0 00-C 0 -/ -/ BO 00-BO 0 00-B 0 00-BJ 0 00-BC CO 0 00-C 0 00-CJ 0 00-CC DO 0 00-D 0 00-DJ 0 00-DC EO 0 00-E 0 00-EJ 0 00-EC FO 0 00-F 0 00-FJ 0 00-FC GO 0 00-G 0 00-GJ 0 00-GC HO 0 00-H 0 00-HJ 0 00-HC JO 0 00-J KO 0 00-K K S P T N KN I Q M R J D H F U B C Fiberglass-reinforced polyester hubs are included with each starter at no additional charge. On size and larger, the auxiliary contact is located on the interposing relay. Does not include line and load lugs, see page - for kits. Size has feed through wiring. Price includes control circuit transformer. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V vaules on page -. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. These devices may be ordered without an auxiliary. - 00

33 Bulletin 00 NEM C Contactors Product Selection, Continued Top Wiring For Motor Loads, Continued Max. Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage 0 Hz Open Type Without Enclosure Without uxiliary Contact With One N.O. uxiliary Contact With One N.O. uxiliary Contact Type General Purpose Enclosure Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight, Corrosion- Resistant Enclosures Stainless Steel NEM Size Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00-O becomes 00-OD. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] C, 0 Hz C, 0 Hz Continuous mpere Rating [] 0-00V - 0 0V V V 0-0 -Phase Power Poles 00V C Maximum 0 Hz 00 -/ -/ 00-TO 0 00-O 00-O J 0 00-C 0 -/ -/ BO 00-BO 0 00-B 0 00-BJ 0 00-BC CO 0 00-C 0 00-CJ 0 00-CC DO 0 00-D 0 00-DJ 0 00-DC EO 0 00-E 0 00-EJ 0 00-EC FO 0 00-F 0 00-FJ 0 00-FC 0 0 Hz -Phase Power Poles 00V C Maximum 0 Hz Continuous NEM mpere 0 0 Size Rating [] 00V 0V V V 0 00-O 00-O J 0 00-C 0 -/ -/ BO 00-BO 0 00-B 0 00-BJ 0 00-BC CO 0 00-C 0 00-CJ 0 00-CC DO 0 00-D 0 00-DJ 0 00-DC EO 0 00-E 0 00-EJ 0 00-EC K S P T N KN I Q M R J D H F U B C Fiberglass-reinforced polyester hubs are included with each starter. On size and larger, the auxiliary contact is located on the control relay. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V vaules on page -. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal ccessories page - Modifications page - Specifications page - pproximate Dimensions page - -

34 Bulletin 00 NEM C Contactors Product Selection, Continued Top Wiring for Motor Loads, Continued Special Purpose Enclosures Description Type X Hazardous Locations Bolted Enclosures Contactor Watertight Corrosion- Resistant Enclosure Fiberglass-Reinforced Type & Class I, Groups C & D Class II, Groups E, F, & G Type R, & Class I, Groups C & D Class II, Groups E, F, & G Size Poles Polyester Divisions & Divisions & 0 N N N N N N N N = vailable N = Not vailable For cat. no. information, please consult your local Rockwell utomation sales office or llen-bradley distributor.. 0 ccessories page - Modifications page - Specifications page - pproximate Dimensions page - -

35 Bulletin 00F NEM C Contactors Feed-Through Wiring for Motor Loads Bulletin 00F Feed-through wiring for motor loads Description The Bulletin 00F C contactor (open type) is available in feed-through wiring construction from NEM size 0. Feed-through contactors have the line terminals at the top of the device and load terminals at the bottom. Bulletin 00F contactors are used for switching C motor loads where overload protection is not required or is provided separately. The contactors may be operated remotely by pilot devices, such as push buttons, selector switches, timers, relays, or temperature switches. Table of Contents ccessories... - Modifications... - Specifications... - Full Load Currents of C Motors... - pproximate Dimensions... - Coil Data... - Size, -Pole Open Type without Enclosure Feed-Through Construction with uxiliary Contact Standards Compliance NEM/EEMC ICS UL 0 CS C. No. CE Marked CS Certified (LR) UL Listed (File No. E, Guide No. NLDX) Feed-Through Wiring for Motor Loads Power Poles 00V C Maximum 0 Hz Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Open Type Without Enclosure Motor Voltage Without uxiliary Contact With One N.O. uxiliary Contact NEM Size Continuous mpere Rating [] V 0V -Phase 0 00F-O 00F-O 0 00F-BO 00F-BO 0 -/ 00F-CO 0 0 -/ 00F-DO 0 00F-EO F-FO 0 Power Poles 00V C Maximum 0 Hz 0 Hz Continuous NEM mpere Rating Size [] 00V 0V 0 V -Phase 0 V 0 00F-O 00F-O 0 -/ -/ F-BO 00F-BO F-CO F-DO F-EO F-FO 0 Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 00F-O becomes 00F-OD. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. [V] 0- BS /. merican Bureau of Shipping UCSG CFR.0 IEEE EN/IEC Certifications C, 0 Hz K S P T N KN I Q M R C, 0 Hz J D H F U B C Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal

36 Bulletin 0 NEM Full Voltage Reversing Starters Product Overview Bulletin 0 Size, with Solid-State Overload Open Type without Enclosure Bulletin 0 NEM sizes 00 Exceptional electrical life UL Witnessed Type Coordination Dependable coil operation Eutectic alloy overload relays: Class 0, 0, or 0 Solid-state overload relays: Class 0,, 0, or 0 Vertically arranged available Bulletin 0V sizes 0 Enclosure ratings NEM Type, R/, /X stainless steel, /X fiberglass reinforced, and & hazardous location -phase and single-phase available Reversing contactors also available Table of Contents Product Selection... - Typical Wiring Diagrams ccessories... - Modifications... - Specifications... - pproximate Dimensions... - Full Load Currents of C Motors... - SMP Solid-State Overload Relay Code Selection... - Heater Element Selection... - Coil Data... - Standards Compliance NEM/EEMC ICS UL 0 CS C. No. BS /. merican Bureau of Shipping UCSG CFR.0 IEEE EN/IEC 0-- CE Marked Certifications CS Certified (LR) UL Listed (File No. E, Guide No. NLDX) Hazardous Location: UL Listed (File No. E0) CS Certified (LR) Description Bulletin 0 reversing starters are most commonly used for full voltage starting and reversing of polyphase squirrel cage motors. Starters Size 00 are electrically and mechanically interlocked to avoid both contactors being closed simultaneously. Bulletin 0V vertically arranged starters are available in Sizes 0 in the open type without enclosure construction only. Bulletin 0 reversing starters are available with Bulletin eutectic alloy overload relays as standard and Bulletin solid-state overloads are optional for additional flexibility in motor protection. 0 -

37 Bulletin 0 NEM Full Voltage Reversing Starters Product Selection Προδυχτ Σελεχτιον Heater Elements Starters with eutectic alloy overload relays require heater elements. See page - for heater element selection tables. Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0- - becomes 0-D-. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-D- becomes 0-D-D. Omission of Overload Relays Bulletin 0 reversing starters are available without overload protection. Cat. nos. for all starters without overload protection will be the listed cat. no. with the No. added. Example: 0-OD- would be 0-OD-. Vertically rranged Full voltage reversing starters, sizes 0, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 0 to 0V. Example: 0V-OD-D with solid-state overload relay and 0V-OD with eutectic alloy overload relay. Fiberglass reinforced polyester hubs are included with each starter. Sizes are painted enclosures. Does not include line and load lugs. See page - for kits. Price includes control circuit transformer. This applies to NEM size enclosed, only. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. When selecting a factory installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0-BB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0-BBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. Typical Wiring Diagrams page -0 ccessories page - Modifications page - Specifications page - pproximate Dimensions page - Heater Element Selection page - -Phase 00V C Maximum 0 Hz with -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Enclosure Surface Mounting Type R/, Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight, Corrosion- Resistant Enclosures Stainless Steel Type X Watertight, Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester Open Type Without Continuous 0 Hz Enclosure mpere NEM Size Rating [] 00V 0V 0 V 0 V 00 -/ -/ 0-TO - 0-T O J - 0-C - 0-S - -/ -/ BO - 0-B - 0-BJ - 0-BC - 0-BS CO - 0-C - 0-CJ - 0-CC - 0-CS DO - 0-D - 0-DJ - 0-DC EO - 0-E - 0-EJ - 0-EC FO - 0-F - 0-FJ - 0-FC GO - 0-G - 0-GJ - 0-GC HO - 0-H - 0-HJ - 0-HC JO - 0-J - 0-JJ KO - 0-K - [V] Common Control Transformer Control Separate Control (without transformer) C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz 0V P T N KN I Q M R H U B C H B C K S J D F

38 0 Bulletin 0 NEM Full Voltage Reversing Starters Product Selection, Continued Heater Elements Starters with eutectic alloy overload relay require heater elements. See page - for heater element selection tables. NEM Size -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Hazardous Locations Motor Voltage Unilock Enclosures Bolted Enclosures Type R, & Type & Class I, Groups C & D Class I, Groups C & D Class II, Groups E, F & G Class II, Groups E, F & G Continuous 0 Hz Divisions & Divisions & mpere Rating [] 00V 0V 0 V 0 V 0 0-U - 0-E - 0-H - -/ -/ BU - 0-BE - 0-BH CE - 0-CH DE - 0-DH EE - 0-EH - Type R, & Class I, Groups C & D Class II, Groups E, F & G Divisions & Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-U - becomes 0-UD-. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, 0 Hz P T N KN I Q M R C, 0 Hz H U B C Transformer Control C, 0 Hz H B C Separate Control (without transformer) C, 0 Hz C, 0 Hz K S J D F Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page page - to complete the cat. no. Example: 0-UD- becomes 0-UD- D. Omission of Overload Relays Bulletin 0 reversing starters are available without overload protection. Cat. nos. for all starters without overload protection will be the listed cat. no. with the No. added. Example: 0-UD- would be 0-UD-. For NEM Type R application it is necessary that a drain or breather and drain be added. See Factory Modifications or ccessories. Includes drain and cover gasket. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0-BUB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0-BUBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. Typical Wiring Diagrams page -0 ccessories page - Modifications page - Specifications page - pproximate Dimensions page - Heater Element Selection page - -

39 Bulletin 0 NEM Full Voltage Reversing Starters Product Selection, Continued Heater Elements Starters with eutectic alloy overload relays require one heater element. See page page - for heater element selection tables. NEM Size Continuous mpere Rating [] No. of Poles -Phase -Pole V C Maximum 0 Hz With -Pole Eutectic Overload Protection Type Of Motor Maximum Horsepower Rating (Each Motor) Full load current of each motor must not exceed Continuous mpere Rating Motor Voltage Open Type Without Enclosure Type General Purpose Enclosure Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight, Corrosion- Resistant Enclosure Stainless Steel Hazardous Location Enclosures Type & Class I, Groups C & D Class II, Groups E, F & G Division & Type R, & Class I, Groups C & D Class II, Groups E, F & G Division & V 0V 00 0 Lead Repulsion Induction Lead Split Phase Lead Repulsion Induction Lead Split Phase Lead Repulsion Induction Lead Split Phase Lead Repulsion Induction Lead Split Phase Lead Split Phase (Break all lines) / 0-TO -0 0-T -0 0-TO -0 0-T -0 Use Size 0 Starter 0-TO -0 0-T -0 0-TO -0 0-T -0 0-O J -0 0-C -0 0-E -0 0-H -0 0-O J -0 0-C -0 0-E -0 0-H -0 0-O J -0 0-C -0 0-E -0 0-H -0 0-O J -0 0-C -0 0-E -0 0-H -0 0-O J -0 0-C -0 Lead Repulsion Induction Lead Split Phase 0-BO -0 0-B -0 0-BJ -0 0-BC -0 0-BE -0 0-BH -0 0-BO -0 0-B -0 0-BJ -0 0-BC -0 0-BE -0 0-BH -0 Lead Repulsion Induction Lead Split Phase Lead Split Phase (Break all lines) 0-BO -0 0-B -0 0-BJ -0 0-BC -0 0-BE -0 0-BH -0 0-BO -0 0-B -0 0-BJ -0 0-BC -0 0-BE -0 0-BH -0 0-BO -0 0-B -0 0-BJ -0 0-BC -0 Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-X -0 becomes 0-XD-0. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Separate Control (without transformer) [V] C, 0 Hz XS XP XT C, 0 Hz XD XH X XF C, 0 Hz XWS XWP XWT C, 0 Hz XWJ XWD XWH XW XWF Ordering Information ll -phase reversing starter orders must be accompanied with a circuit diagram of the motor. Omission of Overload Relays Bulletin 0 reversing starters are available without overload protection. Cat. nos. for all starters without overload protection will be the listed cat. no. with the No. added. Example: 0-OXD-0 would be 0-OXD--0. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0-BX-P-0 will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0-BXJ-P-0 will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. 0 -

40 Bulletin 0 NEM Full Voltage Reversing Starters Typical Wiring Diagrams (See pplicable Codes and Laws) Typical Wiring Diagrams When limit switches are used, remove control wires D and E from the controller and connect the limit switches as per dashed lines. Bulletin 0 Ø -Pole Reversing Starter with Eutectic lloy Overload Relay and Solid-State Overload Relays When limit switches are used, remove control wires D and E from the controller and connect the limit switches as per dashed lines. Bulletin 0 Ø -Pole Reversing Starter without Overload Relay 0 Bulletin 0V Ø -Pole Vertical Reversing Starter with Eutectic lloy Overload Relay, With Solid-State Overload Relays Separate Control Circuit When the controller coils are to operate on a voltage other than line voltage, check coil rating for compatibility and change coils if necessary. Disconnect wires and B from lines L and L. Connect wires and B to the separate control source. Refer to local Electrical Code for control circuit disconnection requirements. Product Selection page - -0

41 Bulletin 0 NEM Full Voltage Reversing Starters Typical Wiring Diagrams, Continued (See pplicable Codes and Laws) Bulletin 0 Ø -Pole (Suffix 0) Reversing Starter with Eutectic lloy Overload Relay When limit switches are used, remove control wires D and E from the controller and connect the limit switches as per dashed lines. Bulletin 0 Ø -Pole (Suffix 0) Reversing Starter with Eutectic lloy Overload Relay When limit switches are used, remove control wires D and E from the controller and connect the limit switches as per dashed lines. Bulletin 0 Ø -Pole (Suffix 0 and 0) Reversing Starter with Eutectic lloy Overload Relay Bulletin 0 Ø -Pole (Suffix 0) Reversing Starter with Eutectic lloy Overload Relay Separate Control Circuit When the controller coils are to operate on a voltage other than line voltage, check coil rating for compatibility and change coils if necessary. Disconnect wires and B from lines L and L. Connect wires and B to the separate control source. Refer to local Electrical Code for control circuit disconnection requirements. 0 Product Selection page - -

42 Bulletin 0 NEM Full Voltage Starters Product Overview Bulletin 0, Size with Eutectic lloy Overload Relay Open Type without Enclosure Bulletin 0 NEM sizes 00 Exceptional electrical life UL Witnessed Type Coordination Dependable coil operation Eutectic alloy overload relays: Class 0, 0, or 0 Solid-state overload relays: Class 0,, 0, and 0 Bulletin 0 starters are designed for full voltage starting of polyphase squirrel cage motors. These starters meet NEM Standards, are easy to wire and service, simple to select, and offer a broad range of NEM sizes 00. These starters may be operated by remote control with push buttons, float switches, thermostats, pressure switches, snap switches, limit switches, or any other suitable two- or three-wire pilot device. ll Bulletin 0 sizes 00 starters are available with Bulletin eutectic alloy overload relays as standard and solid-state overloads are optional for additional flexibility in motor protection. Table of Contents Product Selection... - Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Heater Element Selection... - Standards Compliance NEM/EEMC ICS UL 0 CS C. No. BS /. merican Bureau of Shipping UCSG CFR.0 EN/IEC 0-- CE Marked Certifications CS Certified (LR) UL Listed (File No. E, Guide No. NLDX) Hazardous Location: UL Listed (File No. E0) CS Certified (LR ) 0 -

43 Bulletin 0 NEM Full Voltage Starters Product Selection Προδυχτ Σελεχτιον Bulletin 0, Size with Eutectic lloy Overload Relay, Open Type without Enclosure Heater Elements Starters with eutectic alloy overload relay require heater elements. See page - for heater element selection tables. NEM Size Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-B - becomes 0-BD-. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control Separate Control (without transformer) Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Open Type Without Enclosure 0-0 Type General Purpose Enclosure Surface Mounting Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-BD- becomes 0-BD-D. Sizes are painted enclosures. Fiberglass reinforced polyester hubs are included with each starter. Does not include line and load lugs, see page - for kits. Price includes control current transformer. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0-BB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0-BBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. ccessories page - Modifications page - Specifications page - pproximate Dimensions page -, page - Type R/ Rainproof, Dusttight Industrial Use Enclosure Bulletin 0, Size with Solid-State Overload Relay, Open Type without Enclosure 0-00 Type /X Watertight Corrosion-Resistant Enclosures Stainless Steel 0-0 Type X Watertight Corrosion-Resistant Enclosure Fiberglass- Reinforced Polyester Continuous mpere Rating [] 00V 0V 0 Hz 0 V 0 V 00 -/ -/ 0-TO - 0-T - Use Size 0 starter 0 0-O J - 0-C - 0-S - -/ -/ BO - 0-B - 0-BJ - 0-BC - 0-BS CO - 0-C - 0-CJ - 0-CC - 0-CS DO - 0-D - 0-DJ - 0-DC EO - 0-E - 0-EJ - 0-EC FO - 0-F - 0-FJ - 0-FC GO - 0-G - 0-GJ - 0-GC HO - 0-H - 0-HJ JO - 0-J - 0-JJ KO - 0-K - 0-KJ P T N KN I Q M R H U B C H B C K S J D F

44 Bulletin 0 NEM Full Voltage Starters Product Selection, Continued 0 Heater Elements Starters with eutectic alloy overload relays require heater elements. See page - for heater element selection tables. NEM Size Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-B - becomes 0-BD-. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-BUD- becomes 0-BUD-D. For NEM Type R application it is necessary that a drain or breather and drain be added. See factory modifications or accessories. Omission of Overload Relays Bulletin 0 full voltage starters are available without overload protection. Cat. nos. for all starters without overload protection will be the cat. no. with the No. added. Example: 0-UD- would be 0-UD-. Includes drain and cover gasket. NEM size Unilock enclosed starters have a continuous ampere rating of 0. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0-BUB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0-BUBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. ccessories page - Modifications page - Specifications page - pproximate Dimensions page -, page - - Continuous mpere Rating [] Unilock Enclosure Bulletin 0, Size with Solid-State Overload Relay Bolted Enclosure (Shown with Cover Open) -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Hazardous Locations Full Load Current Must Not Exceed Continuous mpere Rating Unilock Enclosures Bolted Enclosures Motor Voltage Type R, & Class I, Groups C & D Class II, Groups E, F & G 0 Hz Divisions & 0 0 0V V Type & Class I, Groups C & D Class II, Groups E, F & G Divisions & Type R, & Class I, Groups C & D Class II, Groups E, F & G Divisions & 00V V 0 0-U - 0-E - 0-H - -/ -/ BU - 0-BE - 0-BH CU - 0-CE - 0-CH DU - 0-DE - 0-DH EU - 0-EE - 0-EH FU - 0-FE - 0-FH - [V] Common Control Transformer Control Separate Control (without transformer) C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz P T N KN I Q M R H U B C H B C K S J D F - 00

45 Bulletin 0 NEM Full Voltage Starters Product Selection, Continued Heater Elements Starters with eutectic alloy overload relays require heater element. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] -Phase -Pole C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Open Type Without Enclosure Type General Purpose Surface Mounting Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight, Corrosion- Resistant Enclosure Stainless Steel Type X Watertight Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester V 0V 00 / 0-TO - 0-T O J - 0-C - 0-S - 0-BO - 0-B - 0-BJ - 0-BC - 0-BS - P 0-XO - 0-X - 0-XJ - 0-XC - 0-XS - -/ 0-CO - 0-C - 0-CJ - 0-CC - 0-CS - 0 -/ 0-DO - 0-D - 0-DJ - 0-DC - NEM Size Continuous mpere Rating [] -Phase -Pole 0V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type & Class I, Groups C & D Class II, Groups E, F & G Divisions & Hazardous Location Enclosures Type R, & Class I, Groups C & D Class II, Groups E, F & G Divisions & V 0V 0 0-E - 0-H - 0-BE - 0-BH - P 0-XE - 0-XH - -/ 0-CE - 0-CH - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-BX - becomes 0-BXD-. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, 0 Hz XS XP XT C, 0 Hz XD XH X XF Separate Control (without transformer) C, 0 Hz XWS XWP XWT C, 0 Hz XWJ XWD XWH XW XWF Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-BX- becomes 0-BX-SB. Fiberglass reinforced polyester hubs are included with each starter. Includes drain and cover gasket. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0-BX-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0-BXJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. 0 ccessories page - Modifications page - Specifications page - pproximate Dimensions page -, page - -

46 Bulletin 0 NEM Full Voltage Starters Typical Wiring Diagram If the controller coil is to operate on a voltage other than line voltage, check coil rating for compatibility and change coil if necessary. Disconnect wires "" and "B" from Lines L and L. Connect wires "" and "B" to the separate control source. Refer to the National Electrical Code for control circuit disconnection requirements. Note: dditional control circuit overcurrent protection may be required. Refer to the National Electrical Code. The current rating of the control circuit conductors furnished with this device is (Sizes 0 ) or 0 (Size ). -Phase -Wire System 0 -

47 Bulletin 0 NEM Multi-Speed Starters Product Overview Bulletin 0F Size 0, with Eutectic lloy Overload Relay -Speed, Consequent Pole Open Type without Enclosure Bulletin 0 NEM sizes 0 Exceptional electrical life UL Witnessed Type Coordination Dependable coil operation Eutectic alloy overload relays: Class 0, 0, or 0 Solid-state overload relays: Class 0,, 0, or 0 Vertically arranged available Bulletin 0V sizes 0 Bulletin 0 multi-speed starters are designed for the control of two speed squirrel cage motors of either consequent pole or separate winding types. These starters are available for constant horsepower, constant torque or variable torque, three-phase motors. Multi-speed motor starters are commonly used on machine tools, fans, blowers, refrigeration compressors, and many other types of equipment. ll Bulletin 0 multi-speed starters are available with Bulletin eutectic alloy relays as standard and solid-state overloads are optional for additional flexibility in motor protection. Bulletin 0V vertically arranged starters are available in Sizes 0, in the Open Type without Enclosure construction only. Table of Contents Product Overview... this page Product Selection... - Typical Wiring Diagrams... - ccessories... - Modifications... - Specifications... - Full Load Currents of C Motors... - pproximate Dimensions... - Overload Relay Code Selection... - Heater Element Selection... - Standards Compliance NEM/EEMC ICS UL 0 CS C. No. CS Certified (LR) UL Listed (File No. E, Guide No. NLDX) Certifications Hazardous Location: UL Listed (File No. E0) CS Certified (LR ) 0 -

48 0 Bulletin 0 NEM Multi-Speed Starters Product Selection Προδυχτ Σελεχτιον -Speed Separate Winding, -Pole -Pole, Constant or Variable Torque Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage 0 Hz Open Type Without Enclosure Type General Purpose Enclosure Surface Mounting Type R/ Rainproof, Dusttight Industrial Use Enclosure 00V 0V 0 V 0 V 0 0E-O - - 0E E-J - - -/ -/ 0 0 0E-BO - - 0E-B - - 0E-BJ E-CO - - 0E-C - - 0E-CJ E-DO - - 0E-D - - 0E-DJ E-EO - - 0E-E - - 0E-EJ E-FO - - 0E-F - - 0E-FJ E-GO E-HO - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0E- - - becomes 0E-D- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Transformer Control Separate Control (without transformer) [V] C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0E-BD- - becomes Cat No. 0E-BD-D-D. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see page -. Vertically rranged Multi-speed starters, sizes 0, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 0E to 0VE. Example: 0VE-BOD-D-D. Does not include line and load lugs, see page - for kits. Only available on sizes 00. When using V coils on size or, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0E-BB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0E-BBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F

49 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Separate Winding, -Pole -Pole, Constant or Variable Torque, Continued Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type X Type /X Watertight Corrosion- Watertight Corrosion- Resistant Enclosure Resistant Enclosures Fiberglass-Reinforced 0 Hz Stainless Steel Polyester Type & Class I, Groups C & D Class II, Groups E, F & G Divisions & Hazardous Locations Bolted Enclosures Type R, & Class I, Groups C & D Class II, Groups E, F & G Divisions & V 0V V V 0 0E-C - - 0E-S - - 0E-E - - 0E-H - - -/ -/ 0 0 0E-BC - - 0E-BS - - 0E-BE - - 0E-BH E-CC - - 0E-CS - - 0E-CE - - 0E-CH E-DC - - 0E-DE - - 0E-DH E-EC - - 0E-EE - - 0E-EH E-FC - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0E-C - - becomes 0E-CD- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Transformer Control Separate Control (without transformer) [V] C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0E-CD- - becomes Cat No. 0-CD-D-D. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, page -. Fiberglass reinforced polyester hubs are included with each starter. Includes drain and cover gasket. When using V coils on size or, an interposing relay may be required. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0E-BCB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0E-BCBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F

50 0 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Separate Winding, -Pole -Pole, Constant Horsepower Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating 00V Motor Voltage 0V -Phase 00V C Maximum 0 Hz With -Pole Overload Protection 0 Hz Open Type Without Enclosure Type General Purpose Enclosure Surface Mounting Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight Corrosion- Resistant Enclosures Stainless Stee Type X Watertight Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester 0 0 V V 0 0E-O - - 0E E-J - - 0E-C - - 0E-S - - -/ 0E-BO - - 0E-B - - 0E-BJ - - 0E-BC - - 0E-BS - - -/ E-CO - - 0E-C - - 0E-CJ - - 0E-CC - - 0E-CS E-DO - - 0E-D - - 0E-DJ - - 0E-DC E-EO - - 0E-E - - 0E-EJ - - 0E-EC E-FO - - 0E-F - - 0E-FJ - - 0E-FC E-GO - - 0E-G - - 0E-GJ E-HO - - 0E-H - - 0E-HJ - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0E- - - becomes 0E-D- -, and 0E-C - - becomes 0E-CD- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control Separate Control (without transformer) C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0E-D- - becomes 0E-D-D-B. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, page -. Vertically rranged Multi-speed starters, sizes 0, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed from 0E to 0VE. Example: 0VE-OD-B-B. Fiberglass reinforced polyester hubs are included with each starter. Does not include line and load lugs, see page - for kits. When using V coils on size or, an interposing relay may be required. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0E-BB-P, and 0E-BCB-P and will have transformers with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0E-BBJ-P, and 0E- BCBJ-P will have transformers with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F

51 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Separate Winding, -Pole -Pole, Constant Horsepower, Continued Bulletin 0E, Size with Eutectic lloy Overload Relays Bolted Enclosure (with Cover Open) Shown with Optional Modifications Bulletin 0E, Size with Solid-State Overload Relays Bolted Enclosure (with Cover Open) Shown with Optional Modifications Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Hazardous Locations Full Load Current Must Not Exceed Continuous mpere Rating Bolted Enclosures Type & Type R, & Class I, Groups C & D Class I, Groups C & D Class II, Groups E, F & G Class II, Groups E, F & G Motor Voltage Divisions & Divisions & 00V 0V 0 V 0 V 0 0E-E - - 0E-H - - -/ -/ 0E-BE - - 0E-BH - - -/ E-CE - - 0E-CH E-DE - - 0E-DH E-EE - - 0E-EH - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0E-E - - becomes 0E-ED- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Transformer Control Separate Control (without transformer) [V] C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0E-ED- - becomes 0E-ED-D-D. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, see page -. Includes drain and cover gasket. When using V coils on size or, an interposing relay may be required. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0E-BEB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0E-BEBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F

52 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Consequent Pole, -Pole -Pole, Constant or Variable Torque 0 Bulletin 0F, Size with Eutectic lloy Overload Relays Type, General Purpose Enclosure Shown with Cover Removed - Bulletin 0F, Size with Solid-State Overload Relays Type General Purpose Enclosure (with Cover Removed) Type /X Watertight Corrosion-Resistant Enclosure Stainless Steel Type X Watertight Corrosion-Resistant Enclosure Fiberglass-Reinforced Polyester Shown with Optional Pilot Lights and Push Buttons Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] 00V -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating 0V Motor Voltage 0 Hz Open Type Without Enclosure Type General Purpose Enclosure Surface Mounting Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight Corrosion- Resistant Enclosures Stainless Steel Type X Watertight Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester 0 V 0 V 0 0F-O - - 0F F-J - - 0F-C - - 0F-S - - -/ -/ 0 0 0F-BO - - 0F-B - - 0F-BJ - - 0F-BC - - 0F-BS F-CO - - 0F-C - - 0F-CJ - - 0F-CC - - 0F-CS F-DO - - 0F-D - - 0F-DJ - - 0F-DC F-EO - - 0F-E - - 0F-EJ - - 0F-EC F-FO - - 0F-F - - 0F-FJ - - 0F-FC - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0F- - - becomes 0F-D- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control Separate Control (without transformer) C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0F-D- - becomes 0F-D-D-D. Vertically rranged Multi-speed starters, sizes 0, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 0F to 0VF. Example: 0VF-OD-D-D. Size is a painted enclosure. Fiberglass reinforced polyester hubs are included with each starter. For proper overload relay selection, when low speed full load currents are less than, consult your local Rockwell utomation sales office or llen-bradley distributor. Only available on sizes 0. When using V coils on sizes and, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0F-BB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0F-BBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F - 00

53 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Consequent Pole, -Pole -Pole, Constant or Variable Torque, Continued Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Hazardous Locations Full Load Current Must Not Exceed Continuous mpere Rating Bolted Enclosures Motor Voltage Type & Type R, & Class I, Groups C & D Class I, Groups C & D Continuous Class II, Groups E, F & G Class II, Groups E, F & G mpere 0Hz Divisions & Divisions & NEM Size Rating [] 00V 0V 0 V 0 V 0 0F-E - - 0F-H - - -/ -/ 0 0 0F-BE - - 0F-BH F-CE - - 0F-CH F-DE - - 0F-DH - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0F-E - - becomes 0F-ED- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Transformer Control Separate Control (without transformer) [V] C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0F-ED- - becomes 0F-ED-D-D. Includes drain and cover gasket. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0F-BEB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0F-BEBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F

54 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Consequent Pole, -Pole -Pole, Constant Horsepower 0 Bulletin 0G, Size with Eutectic lloy Overload Relays Type, General Purpose Enclosure Shown with Cover Removed - Bulletin 0G, Size with Solid-State Overload Relays Type General Purpose Enclosure (with Cover Removed) Type /X Watertight Corrosion-Resistant Enclosure Stainless Steel Type X Watertight Corrosion-Resistant Enclosure Fiberglass-Reinforced Polyester Shown with Optional Pilot Lights and Push Buttons Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. NEM Size Continuous mpere Rating [] 00V -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating 0V Motor Voltage 0 Hz Open Type Without Enclosure Type General Purpose Enclosure Surface Mounting Type R/ Rainproof, Dusttight Industrial Use Enclosure Type /X Watertight Corrosion- Resistant Enclosures Stainless Steel Type X Watertight Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester 0 V 0 V 0 0G-O - - 0G G-J - - 0G-C - - 0G-S - - -/ -/ 0G-BO - - 0G-B - - 0G-BJ - - 0G-BC - - 0G-BS - - -/ G-CO - - 0G-C - - 0G-CJ - - 0G-CC - - 0G-CS G-DO - - 0G-D - - 0G-DJ - - 0G-DC G-EO - - 0G-E - - 0G-EJ - - 0G-EC G-FO - - 0G-F - - 0G-FJ - - 0G-FC - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0G- - - becomes 0G-D- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Transformer Control Separate Control (without transformer) [V] C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0G-D- - becomes 0G-D-D-D. Vertically rranged Multi-speed starters, sizes 0, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 0G to 0VG. Example: 0VG-OD-D-D. Size is a painted enclosure. Fiberglass reinforced polyester hubs are included with each starter. Only available in sizes 0. When using V coils on sizes and, an interposing relay may be required. See coil V values on page -. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0G-BB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0G-BBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal P T N KN I Q M R H U B C H B C K S J D F - 00

55 Bulletin 0 NEM Multi-Speed Starters Product Selection, Continued -Speed Consequent Pole, -Pole -Pole, Constant Horsepower, Continued Bulletin 0G, Size with Eutectic lloy Overload Relay Bolted Enclosure (with Cover Open) Bulletin 0G, Size with Solid-State Overload Relay Bolted Enclosure (with Cover Open) Heater Elements Starters with eutectic alloy overload relays require heater elements for each speed. See page - for heater element selection tables. -Phase 00V C Maximum 0 Hz With -Pole Overload Protection Maximum Horsepower Rating Hazardous Locations Full Load Current Must Not Exceed Continuous mpere Rating Bolted Enclosures Type & Class I, Groups C & D Type R, & Class I, Groups C & D Continuous Class II, Groups E, F & G Class II, Groups E, F & G mpere Motor Voltage Divisions & Divisions & NEM Size Rating [] 00V 0V 0...V 0 V 0 0G-E - - 0G-H - - -/ -/ 0 0 0G-BE - - 0G-BH G-CE - - 0G-CH G-DE - - 0G-DH - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0G-E - - becomes 0G-ED- -. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Transformer Control Separate Control (without transformer) [V] C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz C, 0 Hz Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: 0G-ED- - becomes 0G-ED-D-D. Includes drain and cover gasket. When selecting a factory-installed control circuit transformer (see Modifications page -), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 0V by default. Example: 0G-BEB-P will have a transformer with a 0V primary/0v secondary voltage and a 0V starter coil. If a starter coil voltage other than 0V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: 0G-BEBJ-P will have a transformer with a 0V primary/v secondary and a V starter coil. This coil is optimized for 0 V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. This coil is optimized for 0 0V, 0 Hz applications, but can be used at 0V, 0 Hz nominal. Typical Wiring Diagrams page - ccessories page - Modifications page - Specifications page - Heater Element Selection page P T N KN I Q M R H U B C H B C K S J D F

56 Bulletin 0 NEM Multi-Speed Starters Typical Wiring Diagrams (See pplicable Codes and Laws) Τψπιχαλ Ωιρινγ Διαγραμσ Size 0 -Speed Separate Winding, Constant or Variable Torque and Constant Horsepower with Eutectic lloy Overload Relay or Solid-State Overload Relay Size 0 -Speed Consequent Pole, Constant or Variable Torque with Eutectic lloy Overload Relay or Solid-State Overload Relay 0 Size 0 -Speed Consequent Pole, Constant Horsepower with Eutectic lloy Overload Relay or Solid-State Overload Relay Product Selection page - -

57 Bulletin 00 C Contactor Overview/Product Selection Bulletin 00 NEM sizes 0 Compact size (space saving design) Guarded terminals Complete range of accessories Solid-state overload relays Electronic and conventional coils mm DIN Rail mountable Bulletin 00 modular line of NEM contactors, when combined with Bulletin solid-state overload relays, auxiliary contacts, interlocks, suppressors, and DIN mounting rail provides the most compact and flexible starter component system available. Table of Contents Product Selection... this page ccessories... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File E0 Guide No. NLDX, NLDX) CE Marked (EN 0--) Product Selection Feed-Through Wiring for Motor Loads NEM Size Continuous mpere Rating [] Coil Voltage Code and Terminal Position (NEM Sizes 0 ) The cat. no. as listed is incomplete. To complete the cat. no., select a Coil Voltage Code from the table below and insert into the cat. no. Example: 0V, 0 Hz: 00-O 0 becomes 00-OD0. [V] C, 0 Hz K Y KP D P KG L C, 0 Hz J X KP D KG H L C, 0/0 Hz KJ KY KP KD KG DC EJ [V] 0 0 Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Open Type Without Enclosure 00V 0V 0 V 0 V 0 00-O BO CO DO EO FO 0 Contactor sizes 0 come standard with N.O. auxiliary contact. Contactor sizes come standard with N.O. and N.C. auxiliary contact C, 0 Hz F V T N G B M C C, 0 Hz T I E N B C C, 0/0 Hz K KB 0 -

58 Bulletin 00 C Contactor Product Selection, Continued Coil Terminal Position ll contactors are delivered with the coil terminals located on the line side. 0 Coil Voltage Code (NEM Sizes ) 00-O 0 Line Side Conventional Coil [V] NEM Size Coil Voltage Code Bulletin -EE Three-Phase Devices Selectable trip class (0,, 0, 0) Selectable manual/auto-manual reset Screw-type control terminals Mounts to NEM Contactor Size djustment Range [] 0 E Overload Relay current range djustable trip class 0 Integrated I/O C, 0 Hz K Y D T N B G M C C, 0 Hz J X D H T N B C Electronic Coil with EI Interface [V] NEM Size C, 0/0 Hz EJ EY EP ED EG E EN EN EN Signal voltage of the Bulletin 00 line electronic interface: Nominal U e : V DC/I e : m Pick-up voltage:.0 0.V DC Drop-out voltage: V DC Electronic Coil with EI Interface [V] NEM Size DC EZJ EZY EZD EZ Signal voltage of the 00 Line electronic interface: Nominal U e : V DC/I e : m Pickup voltage:.0 0.V DC, Dropout Voltage: V DC. Does not include terminal lugs EECB -EEDB -EEEB -EEED -EEFD 0 0 -EEHF EEJF EEJG EEKG NEM Size djustment Range [] 0 -ECD -ECBD -ECCD -ECDD -ECDE 0 -ECEE 0 -ECFF 0 -ECGF 0 -ECGG 0 0 -ECHG -

59 Bulletin 00 C Contactor Product Selection, Continued/ccessories E and E Plus Solid-State Overload Relays Panel Mount Devices for use with External Current Transformers Description djustment Range [] Inputs Output 000 -ECZZ Inputs Outputs Ground Fault Sensor Input PTC Thermistor Input DeviceLogix 000 -ECZZ Current transformers supplied by customer. Refer to Specifications, page - for proper current transformer selection. Order panel adapter, -ECPM, separately. CT Ratio to FL setting range correlation. CT Ratio FL Setting Range [] CT Ratio FL Setting Range [] CT Ratio FL Setting Range [] 0: 00: : 0 00: 0 00: 0 00: 0 0 0: 0 00: 0 000: : 0 00: 0 ccessories uxiliary Contacts Description N.O. N.C. For Use With Bifurcated uxiliary Contact 0 00-F0 00-FB0 00-F 00-FB uxiliary Contact Blocks for Front Mounting 0 00-F0 00-FB0 - - and -pole - Quick and easy mounting without tools - Electronic-compatible contacts down to V, m L L 00-FBL - Mechanically linked performance between N.O. 0 0 and N.C. poles and to the main contactor poles 00-F0 00-FB0 (except for L types) 00-F 00-FB - Models with equal function with several terminal 00-F 00-FB numbering choices L = Late break N.C./early make N.O. 00-F 00-FB 0 00-F0 00-FB0 uxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations - - and -pole - Two-way numbering for right or left mounting on the contactor - Quick and easy mounting without tools - Electronic-compatible contacts down to V, 0 m - Mirror contact performance to the main contactor poles L = Late break N.C./early make N.O. +L +L 00-FL 0 00-SB SB SB SB 0 00-SB0 L L 00-SBL Max. number of auxiliary contacts that may be mounted: C coil contactors max. N.O. contacts on the front of the contactor, N.O. contacts on the side, N.C. front or side, total. DC coil contactors max. N.O. contacts on the front of the contactor or max N.O. contacts on the side, N.C. front or side, total. 0 -

60 Bulletin 00 C Contactor ccessories, Continued 0 Control Modules Pneumatic Timing Modules Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay. Electronic Timing Modules On-Delay Delay of the contactor or control relay solenoid. The contactor or control relay is energized at the end of the delay time. Electronic Timing Modules Off-Delay Delay of the contactor or control relay solenoid. fter interruption of the control signal, the contactor or control relay is de-energized at the end of the delay time. Electronic Timing Modules Delay of the contactor solenoid. Contactor K (Y) is de-energized (off) and K (D) is energized (on) after the end of the set Y end time. (Switching delay at 0 ms.) Continuous adjustment range High repeat accuracy Mechanical Interlocks For interlocking of two contactors. Common interlock for all Bul. 00-C contactor sizes Interlocking of different sizes possible Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts mm dovetail connector included Description For Use With On-Delay 0. 0 s range 0 with C coils 00-FPT0. 0 s range 00-FPT0 Off-Delay 0. 0 s range 0 00-FPTB0. 0 s range 00-FPTB0 On-Delay 0. s range 00-ET 0 s range 00-ET0 0 0 s range 0 00-ET0 0 0V, 0/0 Hz 0 0V DC Off-Delay 0. s range 00-ETB 0 s range 00-ETB0 0 with C coils 0 0 s range 00-ETB0 0 0V, 0/0 Hz Transition Time Y Contactor 0 s range 0 0V, 0/0 Hz Mechanical only without auxiliary contacts Mechanical/ electrical with N.C. auxiliary contacts 0 with C coils 00-ETY MC MC0 Description For Use With Voltage Range Mechanical Latch Following contactor latching, the contactor coil is immediately deenergized (off) by the N.C. auxiliary contact (-). Electrical or manual release N.O. + N.C. auxiliary contacts Suitable for all Bul. 00-C contactor sizes, 0 with C coils 00-FL DC Interface (electronic) Interface between the DC control signal (PLC) and the C operating mechanism of the contactor/control relay. Control (input) voltage V DC 0V DC (V nominal) V DC Requires no additional surge suppression on the relay coils Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted Suitable for all Bul. 00-C contactor sizes, RC, varistor and diode versions RC Module C operating mechanism Varistor Module C/DC operating mechanism 0 with C coils 00-JE 0 with C coils 0 V C, 0/0 Hz 0 0V C, 0/0 Hz 0 0V C, 0/0 Hz V C/ V DC V C/ 0V DC V C/ 0V DC V C 00-FSC 00-FSC0 00-FSC0 00-FSV 00-FSV 00-FSV 00-FSV -0

61 Bulletin 00 C Contactor ccessories, Continued Voltage Suffix Code The cat. no. as listed is incomplete. Select a voltage suffix code from the table below to complete the cat. no. Example: 0V, 0 Hz: 00-FL becomes 00-FLD. Voltage V V 00V 0V 0V 0-0V 0V V 0-00V 00-V 0V 0V 0 Hz K Y KP D V T N G B 0 Hz J D T N B For special voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. ssembly Components 00-S0 Dovetail Connectors For use in contactor and starter assemblies. Single Connector 0 mm Spacing Dovetail Connectors For use in contactor and starter assemblies. Dual Connector mm Spacing Description For Use With Pkg. Quantity S0 00-S 00-SCC Protective Covers Provides protection against unintended manual operation For contactors and front mounted auxiliary contacts, pneumatic timers and latches 0 00-SCC 00-F, -FB, -FC, -FP, -FL 0 00-SCF 00-SCF Reversing Power Wiring Kits 0 0-PW For reversing connection with a solid-state or thermal overload relay 0-PW 0-PW DIN (#) symmetrical rail mm x. mm x m long 0 0 -DR uxiliary Contacts Description No. of N.O. Contacts No. of N.C. Contacts Connection Diagram For Use With uxiliary Contacts Side mounted With IEC sequence terminal designations Left/Right inside mounting Left/Right outside mounting 00-DS- 00-DS- L 00-DS-L Left/Right inside mounting 0 00-DS Left/Right outside mounting 00-DS-0 uxiliary Contacts Electronically compatible auxiliary contacts Ideal for use when switching low-power control circuits With IEC sequence terminal designations Contact ratings: C-, 0V, 0. C-, DC-,...V,...00 m Left/Right inside mounting 00-DS-B -

62 Bulletin 00 C Contactor ccessories, Continued Marking Systems Must be ordered in multiples of package quantities. Suppressor Modules Connecting Components Description Reversing: Input Connection Wye-Delta: Main-Delta connection Description Pkg. Qty. Label Sheet 0 self-adhesive paper labels each, x mm Marking Tag Sheet 0 perforated paper labels each, x mm To be used with a transparent cover Transparent Cover To be used with marking tag sheets Marking Tag dapters To be used with marking tag: Marking Tag dapters To be used with marking tag: Description Suppressor Module for Bul. 00-D Contactors For limiting surge voltage when coil circuits are interrupted Can be plugged into all Bul. 00-D contactors Supplied as standard on all conventional DC coil contactors and all electronic coil contactors (as part of the supply module or delivered with separate suppressor module) Circuit Diagram For overvoltage category IV (IEC for 00-D...-EI) e.g., lightning protection requirements. Suppressor Rating RC Module (C control) for contactors with conventional coil...v, 0 Hz;...V, 0 Hz...0V, 0 Hz; 0...V, 0 Hz 0...V, 0 Hz; 0...V, 0 Hz 0...0V, 0 Hz; V, 0 Hz Output For Use With NEM Sizes Connection 0 mm X 0 00-FMS 0 00-FMP FMC FM FM For Use With NEM Sizes Terminal Connection 00-DFSC 00-DFSC0 00-DFSC0 00-DFSC0 Varistor Module for contactors with conventional coil V C 00-DFSV...V C 00-DFSV...V C 00-DFSV...00V C 00-DFSV 0...V C 00-DFSV0 00-D0-VL 0 mm X Lugs, 00-DL 00-D0-VL 0 mm X 00-D0-VLTB Terminal Blocks, 0 mm X 00-DTB 00-D0-VLTB 0 Reversing: Output Connection Wye-Delta: Delta-Wye connection Delta-Wye connection if 00- D 0 is used as a Wye contactor Wye-Delta: Neutral bridge Power Wiring Kits (for contactors using 00-DL lug kits) 0 mm X 00-D0-VT Lugs, 00-DL 0 mm X 00-D0-VT 0 mm X Terminal Blocks, 00-D0-VTTB 00-DTB 0 mm X 00-D0-VTTB 0 mm X Terminal Blocks, 00-DTB 00-D0-VYTB X 00-D0-VYU X 00-D0-VYU NEM Size Reversing Two-speed, or changeover Wye-Delta/Star-Delta NEM Size Reversing Two-speed, or changeover Wye-Delta/Star-Delta 00-DPW0 00-D0-VL 00-DPY0 00-DPW0 00-D0-VL 00-DPY0 -

63 Bulletin 00 C Contactor ccessories, Continued Connecting Components, Continued Description For Use With NEM Sizes Terminal Lugs 00-DTB0 Set of, -EC_F, -EE_F 00-DTB0 Protection class IPX per IEC 0 and DIN 0 00, -EC_G, -EFC, -EE_G 00-DTB0, -EC_F, -EF_ 00-DL0 Terminal Lugs (UL/CS), Copper Frame (Elec. Coil) 00-DLE0 Set of, -EC_F, -EE_F 00-DL0, -EC_G, -EE_G 00-DL0 00-DL0 Terminal Lugs (UL/CS), luminum Frame Set of (Elec. Coil) and 00-DL0 00-DL0 00-DT Control Circuit Terminal x. mm 00-DT Terminal Shields Set of Protection class IP0 per IEC 0 and DIN 0 00 For direct-on-line, reversing, two-speed, and wyedelta/star-delta assemblies Terminal Covers Protection class IP0 per IEC 0 and DIN 0 00 For direct-on-line, reversing, two-speed, and wyedelta/star-delta assemblies Mounting Plate Galvanized steel plate for starter combinations For direct-on-line, reversing, two-speed, wye-delta/ star-delta, and Dahlander assemblies Mounting Plate For two-speed or changeover switches 00-DTS0 (Elec. Coil) and 00-DTS0 00-DTS0, -EC_F, -EE_F 00-DTC0, -EC_G, -EE_G 00-DTC0 Direct-on-line Reversing, two-speed or changeover Y-Δ or Dahlander Direct-on-line Reversing, two-speed or changeover Y-Δ or Dahlander For interlocking between size and sizes contactors 00-DMS0 00-DMU0 00-DMY0 00-DMS0 00-DMU0 00-DMY0 00-DMU Interlocks Description Circuit Diagram For Use With NEM Sizes Interlock Mechanical Only No additional space required 00-DM00 Interlock Dual Electrical/Mechanical No additional space required N.C. auxiliary contacts Interlock Mechanical Only No additional space required Interlock Mechanical Only Provides interlocking between Bul. 00-C and Bul. 00-D contactors NC NC 00-DMD0 00-DMD00 00-DMC00 0 Interlock Dual Electrical/Mechanical Provides interlocking between Bul. 00-C and Bul. 00-D contactors N.C. auxiliary contacts NC NC 00-DMC0 -

64 Bulletin 00 C Contactor pproximate Dimensions pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Contactors and ccessories Mounting Position C Contactors DIN Mounting Rail -DR NEM Size a b c c c Ød d d 0, (-/) (-/) (-/) (-/). () (-/). (-/). (-/). (/). (/) -. ( - /) -. ( - /) 0 (-/) 00 (-/) (-/) (-/) pprox. Shipping Wt. kg (lbs) 0. (.0). (.0) 0 ccessories Contactors with mm (inches) uxiliary contact block for front mounting - or -pole c/c + (c/c + -/) uxiliary contact block for side mounting - or -pole a + (a + /) Pneumatic Timing Module c/c + (c/c + -/) Electronic Timing Module on coil terminal side b + (b + /) Mechanical Interlock on side of contactor a + (a + /) Mechanical Latch c/c + (c/c + -/) Interface Module on coil terminal side b + (b + /) Surge Suppressor on coil terminal side b + (b + /) Labeling with label sheet marking tag sheet with clear cover marking tag adapter for System V/V marking tag adapter for System Bul. W (+ 0) (+ 0) (+ /) (+ /) -

65 Bulletin 00 C Contactor pproximate Dimensions, Continued pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Contactors and ccessories, Continued øe e e d b c e e Mounting Position 0 0 d a ød c NEM Size a b c c Ød d d Øe e e e e (elect. coil) and 0 (-/) 0 (-/) (-/) 0 (-/) 0 (-/) 0 (-/) (-/) (-/) 0 (-/) 0. (-/) 0. (-/) 0. (-/). (/). (/). (/) Contactors with mm uxiliary contact block 00-DS a 00-DS a +. each Mechanical Interlock 00-DM a + a Frame terminal block 00-DTB0 00-DTB0 00-DTB0 b + each b + each b +. each Label holder c + Conventional DC coil contactors will accept only 00-DS auxiliary contacts. (-/) (-/) 0 (-/) 00 (-/) 00 (-/) 0 (-/) M M M0 (/) 0 (/) (/). (-/) (-/) (-/) (-/) 0 (-/) (-/) (/) 0 (/). (/) 0 -

66 Bulletin 00 C Contactor pproximate Dimensions, Continued pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. E Plus Solid-State Overload Relays F H D B H E TO RESET FROM CONTCTOR MOUNTING HOLE E TO RESET FROM CONTCTOR MOUNTING HOLE T T T NEM Size 0 Overload -EE D R-EE D S-EE D -EE E R-EE E S-EE E Width (-/) (-/) B Height. (-/). (-/) C Depth D E E F H H 0. (-/) 0. (-/). (/). (/). (/). (/). (/) (-/) 0 (-/). (-/) C 0 (-/) 00 (-/) (-/) (-/) 0 -

67 Bulletin 00 C Contactor pproximate Dimensions, Continued pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Panel dapter Mounted L L L H B H E J T T T F D H E C Panel daptor -EPD -EPE Overload -EE D R-EE D S-EE D -EE E R-EE E S-EE E Width (-/) (-/) B Height. (-/) 0. (-/) C Depth D E E F H H H J 0. (-/) (/). (/). (/). (/). (-/). (-/). (-/). (-/). (-/) (-/) 0 (-/) 0 (-/) 0 (-/) (-/). (-/). (-/) DIN Rail / Panel dapter Terminal Cross Sections -EPB -EPD -EPE Single Conductor.0.0 mm. mm.0 mm Flexible-Stranded with Ferrule Torque. N m. N m.0 N m Two Conductor.0.0 mm. 0 mm.0 mm Torque. N m. N m.0 N m Single Conductor..0 mm. mm.0 0 mm Coarse-Stranded/Solid Torque. N m. N m.0 N m Two Conductor..0 mm. mm.0 mm Torque. N m. N m.0 N m Single Conductor WG WG WG Stranded/Solid Torque lb in 0 lb in lb in Two Conductor 0 WG WG WG Torque lb in 0 lb in lb in For multiple conductor applications, the same size and style wire must be used. 0 -

68 Bulletin 00 C Contactor pproximate Dimensions, Continued pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bulletin 00 Contactor with Overload Relay D ød H J D E B B E C Overload NEM Size -EC D 0 -EC E Width (-/) (-/) without -EIMD. (-/). (-/) B Height with -EIMD 0. (-/). (0-/) B. (-/). (-/) C Depth E E 0 (-/). (-/). (/). (/). (-/). (-/) Overload NEM Size D D H J ØD -EC D 0 -EC E 0 (-/) 00 (-/) (-/) (-/) 0 (-/). (-/) (/) (/) ø. (/ø) ø. (/ø) 0 -

69 Bulletin 00 C Contactor pproximate Dimensions, Continued pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. B Height Overload -EC F NEM Size -EC G Width 0 (-/) 0 (-/) (-/0) without Terminal Covers. (-/). (-/). (-/) with Terminal Covers (-/) (-/). (-/) B. (-/). (-/) 0. (-/) C Depth D E E. (-/). (-/). (-/) (-/) (-/) 0 (-/). (/). (/). (/). (-/). (-/) (0-/) Overload NEM Size F G H J K L M -EC F -EC G. (/) (/) (/) 00 (-/) 00 (-/) 0 (-/) (-/) (-/) 0 (-/) (-/) (-/) 0 (-/). (/). (/). (/) 0. (-/) 0. (-/) 0. (-/) -. ( - /) -. ( - /) -. ( - /) 0 -

70 Bulletin 00 C Contactor pproximate Dimensions, Continued pproximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Panel Mount dapters (For Use With -EC D, - EC_ZZ) (-/). (-/). (-) (-/) 00. (-/) ø. (/ ø) 0 (-/). (/). (/) (-/) (For Use With -EC E). (-/) 0 (-/). (/) 0. (-/). (-/) w/ -EIMD 0 (-/) (/) ( - /) (-/) (/) ø. (/ ø). (-/) 0-0

71 NEM Combination Starters and Pump Panels NEM Combination Starters and Pump Control Panels Product Overview Features Bulletin 0/0 0/0 /, M/M H/H V/V Disconnecting Means Type Painted Metal Enclosure Latch Fastener Type R// Painted Metal Enclosure Screw Fasteners Type R// Painted Metal Enclosure Door Safety Hardware Type /X Stainless Steel Enclosure Screw Fasteners Type /X Fiberglass Reinforced Polyester Enclosure Screw Fasteners Product Selection Non-reversing combination contactor 0 disconnect switch 0 circuit breaker Reversing combination starter 0 disconnect switch 0 circuit breaker NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 NEM Size 0 Page - (Bul. 0) or page - (Bul. 0) Page - (Bul. 0) or page - (Bul. 0) Non-reversing combination starter and non-reversing starter with extra panel space /M disconnect switch /M circuit breaker NEM Size: 0 (/), (M/M) NEM Size: 0 (/), (M/M) NEM Size: 0 (/), (M/M) NEM Size: 0 (/), (M/M) NEM Size: 0 (/), (M/M) Page - (Bul. ), page - (Bul. M), page - (Bul. ), page - (Bul. M) Non-reversing combination starter mounted in a horizontal enclosure H disconnect switch H circuit breaker Non-reversing vacuum combination starter V disconnect switch V circuit breaker NEM Size NEM Size NEM Size NEM Size NEM Size Page -0 (Bul. H) or page - (Bul. H) Page - (Bul. V) or page - (Bul. V) Bulletin / X/X V/V Combination multi-speed starter constant horsepower Combination multi-speed Features starter constant or variable torque Combination multi-speed starter consequent pole E,F,G disconnect switch Disconnecting Means E,F,G circuit breaker Type Painted Metal Enclosure Latch Fastener Type R// Painted Metal NEM Size Enclosure Screw Fasteners Type R// Painted Metal Enclosure Door Safety Hardware Type /X Stainless Steel Enclosure Screw Fasteners Type /X Fiberglass Reinforced Polyester Enclosure Screw Fasteners Page -0 (Bul. ) Product Selection or page - (Bul. ) Non-reversing starter with extra panel space X disconnect switch X circuit breaker Non-reversing vacuum pump control panel V disconnect switch V circuit breaker Combination oil well pump control panel circuit breaker NEM Size NEM Size (Type R only) NEM Size (Type R only) NEM Size NEM Size NEM Size NEM Size Page - (Bul. X) or page -00 (Bul. X) Page - (Bul. V) or page -0 (Bul. V) Page

72 0 Bulletin 0 NEM Combination Starters Explanation Configuration of a Basic Combination Starter The information below is for reference purposes. Not all combinations will produce a valid Refer to the tables on the following pages for product selection. Example a Bulletin No. Bulletin Description No. Combination contactor with 0 disconnect switch Combination contactor with circuit 0 breaker Reversing combination starter with 0 disconnect switch Reversing combination starter with 0X disconnect switch in a narrow enclosure Reversing combination starter with 0 circuit breaker Reversing combination starter with 0X circuit breaker in a narrow enclosure Non-reversing combination starter with disconnect switch Horizontal mounting combination H starter with disconnect switch Non-reversing combination starter with M disconnect switch extra panel space Non-reversing vacuum combination V starter with disconnect switch Non-reversing combination starter with circuit breaker Horizontal mounting combination H starter with circuit breaker Non-reversing combination starter with M circuit breaker extra panel space Non-reversing vacuum combination V starter with circuit breaker -speed, -winding, full voltage, multispeed combination starter with E disconnect switch -speed, -winding, constant or variable torque, full voltage, multispeed combination starter with F disconnect switch -speed, -winding, constant horsepower, full voltage, multi-speed G combination starter with disconnect switch -speed, -winding, full voltage, multispeed combination starter with circuit E breaker -speed, -winding, constant or variable torque, full voltage, multispeed combination starter with circuit F breaker -speed, -winding, constant G horsepower, full voltage, multi-speed combination starter with circuit breaker X Pump panel with disconnect switch Pump panel with vacuum contactor V and disconnect switch X Pump panel with circuit breaker Pump panel with vacuum contactor V and circuit breaker CD D R 0 a b c d e f b d Starter Size NEM NEM Size Code Size 0 B C D E F G H c Enclosure Type Code Type Type : General Purpose, painted metal enclosure with spring latch door fastener, external overload relay reset, and nonmetallic handle Type R//: Rainproof, watertight, dusttight, painted metal enclosure with F screw fasteners, external overload relay reset, and non-metallic handle Type R//: Rainproof, watertight, dusttight, painted metal enclosure with J door safety hardware, metal handle, and NO external overload relay reset Type R//: Rainproof, watertight, dusttight, painted metal enclosure with D door safety hardware, external overload relay reset, and metal handle Type R: Rainproof, painted metal extracapacity enclosure with screw fasteners, N external overload relay reset, and a nonmetallic handle Type /X: Watertight corrosion-resistant stainless steel enclosure with screw C fasteners, external overload relay reset, and a stainless steel handle Type /X: Watertight corrosion-resistant non-metallic enclosure with screw S fasteners, external overload relay reset, and a non-metallic handle Type : Hazardous location (Class II, Division, Group F + G and Class III, Divisions + ) painted metal enclosure K with screw fasteners, NO external overload relay reset, and a non-metallic handle. Type : Hazardous location (Class II, Division, Group F + G and Class III, L Divisions + ) painted metal enclosure with screw fasteners, external overload relay reset, and a non-metallic handle. Type +: Hazardous location bolted E enclosure, metal handle. Type R//: Hazardous location bolted H enclosure, rain proof, metal handle. Type R//: Hazardous location Unilock U enclosure, rain proof, metal handle. Coil Voltage Line Coil Voltage Description Voltage Voltage Code (V) (V) H 0 0 Common Control 0 0 (without B transformer) 0 0 C H 0 0 Transformer 0 0 B Control 0 0 C 00 0 HD 0 0 D Separate Control 0 0 (without BD transformer) 0 0 CD 00 0 e Overload Relay Code Description None Eutectic lloy See page - Solid-State f Options See page - Note When selecting a factory-installed control circuit transformer use the Transformer Control Voltage Suffix Code to denote the transformer primary voltage. The transformer secondary voltage and starter coil will both be 0V C by default. Example: -BB-P- R will have a transformer with a 0V primary voltage, 0V secondary voltage, and a 0V starter coil voltage. -

73 Bulletin 0 NEM Combination Starters Disconnect Type NEM Size Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Bulletin 0 NEM contactor sizes 0 (no overload relay) Fusible or non-fusible disconnect switch Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Non-metallic enclosures: Type /X Modifications factory-installed ccessories field-installed Service entrance rated Bulletin 0 combination contactor consists of a Bulletin 00, -pole contactor, and a disconnect switch (fused or non-fused) mounted in a common enclosure. Fuse Clip Rating mperes [] Fuses not included. Select per NEC Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Table of Contents ccessories... - Modifications... - Specifications... - Full Load Currents of C Motors... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NLDX, NLDX) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Non-metallic Motor Voltage 0 Hz 0 Hz 0 Hz 0 0 Hz 0 Line Voltage 00V 0V V V [V] R 0-F -R 0-J -R 0-C -R 0-S -R R 0-F -R 0-J -R 0-C -R 0-S -R -/ -/ B -R 0-BF -R 0-BJ -R 0-BC -R 0-BS -R B -R 0-BF -R 0-BJ -R 0-BC -R 0-BS -R -/ -/ B -R 0-BF -R 0-BJ -R 0-BC -R 0-BS -R B -R 0-BF -R 0-BJ -R 0-BC -R 0-BS -R C -R 0-CF -R 0-CJ -R 0-CC -R 0-CS -R C -R 0-CF -R 0-CJ -R 0-CC -R 0-CS -R C -R 0-CF -R 0-CJ -R 0-CC -R 0-CS -R C -J 0-CF -J 0-CJ -J 0-CC -J 0-CS -J C -J 0-CF -J 0-CJ -J 0-CC -J 0-CS -J D -R 0-DF -R 0-DJ -R 0-DC -R 0-DS -R D -R 0-DF -R 0-DJ -R 0-DC -R 0-DS -R D -R 0-DF -R 0-DJ -R 0-DC -R 0-DS -R D -J 0-DF -J 0-DJ -J 0-DC -J 0-DS -J D -J 0-DF -J 0-DJ -J 0-DC -J 0-DS -J E -R 0-EF -R 0-EJ -R 0-EC -R 0-ES -R E -R 0-EF -R 0-EJ -R 0-EC -R 0-ES -R E -R 0-EF -R 0-EJ -R 0-EC -R 0-ES -R E -J 0-EF -J 0-EJ -J 0-EC -J 0-ES -J E -J 0-EF -J 0-EJ -J 0-EC -J 0-ES -J F -R 0-FF -R 0-FJ -R 0-FC -R 0-FS -R F -R 0-FF -R 0-FJ -R 0-FC -R 0-FS -R F -R 0-FF -R 0-FJ -R 0-FC -R 0-FS -R F -R 0-FF -R 0-FJ -R 0-FC -R 0-FS -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: 0- -R becomes 0-B-R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page - Note) 0 Hz 0V Separate Control (without transformer) D D CD CD Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: 0-BFB-R becomes 0-BFB. Class H fuse clips can be supplied. Example: 0- -R becomes Class J fuse clips can be supplied. Example: 0- - R becomes 0- -J. Class HRC form II fuse clips can be supplied. Example: 0- -R becomes 0- -E. 0 -

74 Bulletin 0 NEM Combination Contactors Circuit Breaker Type Bulletin 0 NEM contactor sizes 0 Circuit breaker thermal magnetic (inverse time) Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Non-metallic enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Bulletin 0 combination contactor consists of a Bulletin 00, -pole contactor, and a thermal magnetic circuit breaker (inverse time) mounted in a common enclosure. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NLDX, NLDX) 0 NEM Size Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Nonmetallic Motor Voltage 00V 0V 0V V 0 / 0 / 0- -T 0-F -T 0-J -T 0-C -T 0-S -T / / T 0-F -T 0-J -T 0-C -T 0-S -T -/ -/ -/ -/ 0- -T 0-F -T 0-J -T 0-C -T 0-S -T 0- -T 0-F -T 0-J -T 0-C -T 0-S -T 0 / 0 / 0-B -T 0-BF -T 0-BJ -T 0-BC -T 0-BS -T / / B -T 0-BF -T 0-BJ -T 0-BC -T 0-BS -T -/ -/ -/ -/ 0-B -T 0-BF -T 0-BJ -T 0-BC -T 0-BS -T 0-B -T 0-BF -T 0-BJ -T 0-BC -T 0-BS -T -/ -/ -/ -/ 0-B -0T 0-BF -0T 0-BJ -0T 0-BC -0T 0-BS -0T B -T 0-BF -T 0-BJ -T 0-BC -T 0-BS -T C -T 0-CF -T 0-CJ -T 0-CC -T 0-CS -T 0-C -T 0-CF -T 0-CJ -T 0-CC -T 0-CS -T C -T 0-CF -T 0-CJ -T 0-CC -T 0-CS -T 0 0-D -T 0-DF -T 0-DJ -T 0-DC -T 0-DS -T D -T 0-DF -T 0-DJ -T 0-DC -T 0-DS -T D -T 0-DF -T 0-DJ -T 0-DC -T 0-DS -T 0 0-E -T 0-EF -T 0-EJ -T 0-EC -T 0-ES -T E -T 0-EF -T 0-EJ -T 0-EC -T 0-ES -T 0 0-E -T 0-EF -T 0-EJ -T 0-EC -T 0-ES -T 0 0-E -T 0-EF -T 0-EJ -T 0-EC -T 0-ES -T 0 0-E -T 0-EF -T 0-EJ -T 0-EC -T 0-ES -T E -0T 0-EF -0T 0-EJ -0T 0-EC -0T 0-ES -0T F -T 0-FF -T 0-FJ -T 0-FC -T 0-FS -T 0 0-F -T 0-FF -T 0-FJ -T 0-FC -T 0-FS -T 00 0-F -0T 0-FF -0T 0-FJ -0T 0-FC -0T 0-FS -0T 0-F -T 0-FF -T 0-FJ -T 0-FC -T 0-FS -T 0 0-F -T 0-FF -T 0-FJ -T 0-FC -T 0-FS -T F -T 0-FF -T 0-FJ -T 0-FC -T 0-FS -T When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: 0-B -T becomes 0-BB-T. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD To order contactors (sizes 0 ) with current limiters, change the letter T to D at the end of the listed cat. no. Example: 0- -D. -

75 Bulletin 0 NEM Combination Reversing Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) NEM Size Cont. mpere Rating [] Bulletin 0 NEM starter sizes 0 Overload relays: Eutectic supplied as standard, solid-state available as an option Fusible or non-fusible disconnect switch Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Non-metallic enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Bulletin 0 combination reversing starter consists of a Bulletin 0 reversing starter and a disconnect switch (fused or non-fused) mounted in a common enclosure. Heater Elements Starters with eutectic alloy overload relays require heater elements. Located on page -. Max. Hp Rating Fuse Clip Type R// FLC Must Not Exceed Rating Rainproof, Type /X Type /X Continuous mp Rating mperes Type R// Waterproof, Watertight Watertight Motor Voltage [] Type Rainproof, Dusttight Corrosion- Corrosion- Fuses not General Waterproof, (Door Safety Resistant Resistant 0 Hz 0 Hz 0 Hz 0 Hz Line included. Purpose Dusttight Hardware) Stainless Steel Non-metallic 0 0 Voltage Select per 00V 0V V V [V] NEC R 0-F - -R 0-J - -R 0-C - -R 0-S - -R R 0-F - -R 0-J - -R 0-C - -R 0-S - -R -/ -/ B - -R 0-BF - -R 0-BJ - -R 0-BC - -R 0-BS - -R B - -R 0-BF - -R 0-BJ - -R 0-BC - -R 0-BS - -R -/ -/ B - -R 0-BF - -R 0-BJ - -R 0-BC - -R 0-BS - -R B - -R 0-BF - -R 0-BJ - -R 0-BC - -R 0-BS - -R C - -R 0-CF - -R 0-CJ - -R 0-CC - -R 0-CS - -R C - -R 0-CF - -R 0-CJ - -R 0-CC - -R 0-CS - -R C - -R 0-CF - -R 0-CJ - -R 0-CC - -R 0-CS - -R C - -R 0-CF - -R 0-CJ - -R 0-CC - -J 0-CS - -J C - -J 0-CF - -J 0-CJ - -J 0-CC - -J 0-CS - -J D - -J 0-DF - -J 0-DJ - -J 0-CC - -R 0-DS - -R D - -R 0-DF - -R 0-DJ - -R 0-DC - -R 0-DS - -R D - -R 0-DF - -R 0-DJ - -R 0-DC - -R 0-DS - -R D - -J 0-DF - -J 0-DJ - -J 0-DC - -J 0-DS - -J D - -J 0-DF - -J 0-DJ - -J 0-DC - -J 0-DS - -J E - -R 0-EF - -R 0-EJ - -R 0-EC - -R 0-ES - -R E - -R 0-EF - -R 0-EJ - -R 0-EC - -R 0-ES - -R E - -R 0-EF - -R 0-EJ - -R 0-EC - -R 0-ES - -R E - -R 0-EF - -R 0-EJ - -R 0-EC - -R 0-ES - -J E - -J 0-EF - -J 0-EJ - -J 0-EC - -J 0-ES - -J F - -R 0-FF - -R 0-FJ - -R 0-FC - -R 0-FS - -R F - -R 0-FF - -R 0-FJ - -R 0-FC - -R 0-FS - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: R becomes 0-B- -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] 0V 0 0V 0 0V 00V Common Control Transformer Control (See page -0 Note) 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-B- -R becomes 0-B-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: 0-BFB-R becomes 0-BFB. Class H fuse clips can be supplied. Example: 0- -R becomes Class J fuse clips can be supplied. Example: 0- -R becomes 0- -J. Class HRC form II fuse clips can be supplied. Example: 0- -R becomes 0- - E. Bulletin 0 Narrow Enclosure Sizes 0 & are supplied in a (0 in. H x 0 in. W) enclosure. If a narrow enclosure ( in. H x 0 in. W) is required, add the letter X to the Bulletin Number (0X). Only available in Type or. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NLDX, NLDX) - 0

76 Bulletin 0 NEM Combination Reversing Starters Circuit Breaker Type 0 NEM Size Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-BB- - becomes 0-BB-D-. Bulletin 0 Narrow Enclosure Sizes 0 & are supplied in a (0 in. H x 0 in. W) enclosure. If a narrow enclosure ( in. H x 0 in. W) is required, add the letter X to the Bulletin Number (0X). To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: 0-B - -V. - Continuous mpere Rating [] Bulletin 0 NEM starter sizes 0 Overload relays: Eutectic supplied as standard, solid-state available as an option Circuit breaker magnetic only (instantaneous) Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Non-metallic enclosures: Type /X Hazardous location enclosures: Type R, & Modifications factory installed ccessories field installed Service entrance rated Bulletin 0 combination reversing starter consists of a Bulletin 0 reversing starter and a circuit breaker magnetic only (instantaneous trip) mounted in a common enclosure. Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Type R// Rainproof, Waterproof, Dusttight When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: 0-B - - becomes 0-BB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Table of Contents Modifications... - ccessories... - pproximate Dimensions... - FLC of C Motors... - Standards Compliance UL 0 CS C., No. Certifications Ordinary Locations culus Listed (File No. E, Guide No. NKJH, NKJH) Hazardous Locations culus Listed (File No. E, Guide No. NOTH, NOTH) Type /X Watertight Corrosion Resistant Stainless Steel Type /X Watertight Corrosion Resistant Non-mettalic 00V 0V 0V V 0 / 0 / F J C S - - / / F J C S - - -/ -/ -/ -/ F J C S F J C S / 0 / 0-B BF BJ BC BS - - / / B BF BJ BC BS - - -/ -/ -/ -/ 0-B BF BJ BC BS B BF BJ BC BS - - -/ -/ -/ -/ 0-B BF BJ BC BS B BF BJ BC BS C CF CJ CC CS C CF CJ CC CS C CF CJ CC CS D DF DJ DC DS D DF DJ DC DS D DF DJ DC DS E EF EJ EC ES E EF EJ EC ES E EF EJ EC ES E EF EJ EC ES E EF EJ EC ES E EF EJ EC ES F FF FJ FC FS F FF FJ FC FS F FF FJ FC FS F FF FJ FC FS F FF FJ FC FS F FF FJ FC FS - - [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control HD D BD CD

77 Bulletin 0 NEM Combination Reversing Starters Circuit Breaker Type, Continued NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type & Bolted Class I, Groups C & D Class II, Groups E, F & G Divisions & Type R, & Bolted Class I, Groups C & D Class II, Groups E, F & G Divisions & Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: 0-BE - - becomes 0-BEB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-BEB- - becomes 0-BEB-D-. Includes drain and cover with gasket. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: 0-BE - -V. Type R, & Unilock Class I, Groups C & D Class II, Groups E, F & G Divisions & 00V 0V 0V V 0 / 0 / 0-E H U - - / / E H U - - -/ -/ -/ -/ 0-E H U E H U / 0 / 0-BE BH BU - - / / BE BH BU - - -/ -/ -/ -/ 0-BE BH BU BE BH BU - - -/ -/ -/ -/ 0-BE BH BU BE BH BU CE CH CU CE CH CU CE CH CU DE DH DU DE DH DU DE DH DU EE EH EU EE EH EU EE EH EU EE EH EU EE EH EU EE EH EU - -0 When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control HD D BD CD 0 -

78 Bulletin NEM Combination Non-Reversing Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) Bulletin NEM starter sizes 0 Fusible or non-fusible disconnect switch Overload relays: eutectic supplied as standard, solid-state available as an option Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Non-metallic enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Bulletin combination non-reversing starter consists of a Bulletin 0 starter and a disconnect switch (fused or unfused) mounted in a common enclosure. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS., No. Certifications Fusible Versions culus Listed (File No. E, Guide No. NKJH, NKJH) Non-Fusible Versions culus Listed (File No. E, Guide No. NLDX, NLDX) merican Bureau of Shipping 0 NEM Size Continuous mpere Rating [] 0 Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Max. Hp Rating Full Load Current Must Type R// Not Exceed Continuous Fuse Clip Rainproof, Type /X Type X mpere Rating Rating Type R// Waterproof, Watertight Watertight mperes Type Rainproof, Dusttight Corrosion- Corrosion- Motor Voltage [] General Waterproof, (Door Safety Resistant Resistant 0 Hz 0 Hz 0 Hz 0 Hz Fuses not Purpose Dusttight Hardware) Stainless Steel Non-Metallic 00V 0V 0 V 0 V Line Voltage [V] included. Select per NEC R -F - -R -J - -R -C - -R -S - -R R -F - -R -J - -R -C - -R -S - -R -/ -/ B - -R -BF - -R -BJ - -R -BC - -R -BS - -R B - -R -BF - -R -BJ - -R -BC - -R -BS - -R -/ -/ B - -R -BF - -R -BJ - -R -BC - -R -BS - -R B - -R -BF - -R -BJ - -R -BC - -R -BS - -R C - -R -CF - -R -CJ - -R -CC - -R -CS - -R C - -R -CF - -R -CJ - -R -CC - -R -CS - -R C - -R -CF - -R -CJ - -R -CC - -R -CS - -R C - -J -CF - -J -CJ - -J -CC - -J -CS - -J C - -J -CF - -J -CJ - -J -CC - -J -CS - -J Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: - - -R becomes -B- -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -B- -R becomes -B-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: -BFB-R becomes -BFB. Class H fuse clips can be supplied. Example: - -R becomes - -. Class J fuse clips can be supplied. Example: - -R becomes - -J. Class HRC form II fuse clips can be supplied. Example: - -R becomes - -E. Type R// starters do not include an external reset button for the overload relay. To order an external reset, replace the second letter J in the listed cat. no. with the letter D. Example: -J - -R becomes -D - -R. -

79 Bulletin NEM Combination Non-Reversing Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible), Continued NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Max. Hp Rating Full Load Current Must Type R// Not Exceed Continuous Fuse Clip Rainproof, Type /X Type X mpere Rating Rating Type R// Waterproof, Watertight Watertight mperes Type Rainproof, Dusttight Corrosion- Corrosion- Motor Voltage [] General Waterproof, (Door Safety Resistant Resistant 0 Hz 0 Hz 0 Hz 0 Hz Fuses not Purpose Dusttight Hardware) Stainless Steel Non-Metallic 00V 0V 0 V 0 V Line Voltage [V] included. Select per NEC D - -R -DF - -R -DJ - -R -DC - -R -DS - -R D - -R -DF - -R -DJ - -R -DC - -R -DS - -R D - -R -DF - -R -DJ - -R -DC - -R -DS - -R D - -J -DF - -J -DJ - -J -DC - -J -DS - -J D - -J -DF - -J -DJ - -J -DC - -J -DS - -J E - -R -EF - -R -EJ - -R -EC - -R -ES - -R E - -R -EF - -R -EJ - -R -EC - -R -ES - -R E - -R -EF - -R -EJ - -R -EC - -R -ES - -R E - -J -EF - -J -EJ - -J -EC - -J -ES - -J E - -J -EF - -J -EJ - -J -EC - -J -ES - -J F - -R -FF - -R -FJ - -R -FC - -R -FS - -R F - -R -FF - -R -FJ - -R -FC - -R -FS - -R F - -R -FF - -R -FJ - -R -FC - -R -FS - -R GF - -R -GC - -J HF - -L Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: - - -R becomes -B- -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -B- -R becomes -B-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: -BFB-R becomes -BFB. Class H fuse clips can be supplied. Example: - -R becomes - -. Class J fuse clips can be supplied. Example: - -R becomes - -J. Class HRC form II fuse clips can be supplied. Example: - -R becomes - -E. For 0V and 0V Hp ratings, limit the maximum fuse sizing to % of motor full load current. 0 -

80 Bulletin H Horizontal Mounting Disconnect Type Overview/Catalog Number Explanation Bulletin H Horizontal Mounting Combination Starter NEM starter sizes Fusible or non-fusible disconnect switch Overload relays: Eutectic supplied as standard, solid-state available as an option Painted metal enclosures: Type R// Modifications factory installed ccessories field installed Service entrance rated Bulletin H combination non-reversing starter consists of a Bulletin 0 starter and a disconnect switch (fused or unfused) mounted in a horizontal enclosure. Configuration of a Basic Combination Starter The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. Example H B D CD D E a b c d e f Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS., No. Certifications Fusible Versions UL Listed (File No. E, Guide No. NKJH) CS (File No. LR) Non-Fusible Versions UL Listed (File No. E, Guide No. NLDX) CS (File No. LR) merican Bureau of Shipping 0 Bulletin No. H H NEM Size Code a Bulletin No. Description Horizontal mounting combination starter with disconnect switch Horizontal mounting combination starter with circuit breaker b Starter Size NEM Size B C Code J D c Enclosure Type Type Type R//: rainproof, watertight, dusttight, painted metal enclosure with door safety hardware, metal handle, and NO external overload relay reset Type R//: rainproof, watertight, dusttight, painted metal enclosure with door safety hardware, external overload relay reset, and metal handle Code None See Industrial Controls catalog d Coil Voltage Line Coil Voltage Description Voltage Voltage Code [V] [V] H 0 0 Common control 0 0 (without B transformer) 0 0 C H 0 0 Transformer 0 0 B Control 0 0 C 00 0 HD 0 0 D Separate control 0 0 (without BD transformer) 0 0 CD 00 0 e Overload Relay Description Eutectic alloy Solid-state f Options See page - Note When selecting a factory-installed control circuit transformer use the Transformer Control Voltage Suffix Code to denote the transformer primary voltage. The transformer secondary voltage and starter coil will both be 0V C by default. Example: -BB-P-R will have a transformer with a 0V primary voltage, 0V secondary voltage, and a 0V starter coil voltage. -0

81 Bulletin H Horizontal Mounting Disconnect Type Product Selection NEM Size Continuous mpere Rating [] Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Max. Hp Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage, 0 Hz Type R// Rainproof, Waterproof, Dusttight with Door Safety Hardware & External Overload Relay Reset Type R// 00V 0V 0V V Coil Voltage [V] Fuse Clip Rating mperes [] Fuses not included. Select per NEC Rainproof, Waterproof, Dusttight with Door Safety Hardware Fusible Disconnect Type with Class H, J, and K Fuse Clips. 0 0 H-BJH- H-BDH- 0 H-BJH- H-BDH H-BJ- H-BD- 0 H-BJ- H-BD H-BJB- H-BDB- 0 H-BJB- H-BDB H-BJC- H-BDC- 0 H-BJC- H-BDC H-CJH- H-CDH- 00 H-CJH- H-CDH- 0 0 H-CJ- H-CD- 00 H-CJ- H-CD- 0 0 H-CJB- H-CDB- 00 H-CJB H-CJC- H-CDC- 00 H-CJC- Note: Class R fuse clips can be supplied as a factory option in place of standard clips by adding and R after the digit which indicated the fuse clip size. 0V Separate Control (Control Circuit Transformer not supplied) To order a 0V or 0V starter with 0V separate control, change the third letter following the first dash in the listed catalog number to D. The D represents 0V and corresponds to the fuse clip spacing. To order a 0V or 00V starter, change the third letter following the first dash in the listed catalog number to CD. The CD represents 00V and corresponds to the fuse clip spacing. List prices apply. When ordering a separate control circuit transformer select the primary voltage on the basis of the actual system line voltage. 0V Separate Control (Control Circuit Transformer not supplied) To order a non-fusible type starter with 0V coil for separate control, change the third letter following the first dash in the listed catalog number to D. List prices apply. Class H and K fuse clips will also accept Class R fuses. Class R fuse clips are the rejection type and will accept Class R fuses only. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: -BFB-R becomes -BFB. 0 -

82 Bulletin M NEM Combination Non-Reversing Starters with Extra Panel Space Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) Bulletin M NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state available as an option Fusible or non-fusible disconnect switch Painted metal extra capacity enclosures: Type R// Stainless steel extra capacity enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Bulletin M combination non-reversing starter consists of a Bulletin 0 starter and a disconnect switch (fused or unfused) mounted in a common enclosure with extra panel space. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS., No. Certifications Fusible Versions culus Listed (File No. E, Guide No. NKJH, NKJH) Non-Fusible Versions culus Listed (File No. E, Guide No. NLDX, NLDX) merican Bureau of Shipping 0 NEM Size Continuous mpere Rating [] Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage 0 Hz 0 Hz 0 Hz 0 Hz 00V 0V 0 V 0 V Line Voltage [V] -/ -/ Fuse Clip Rating mperes [] Fuses not included. Select per NEC Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight, Corrosion- Resistant, Stainless Steel 0 M-BF - -R M-BJ - -R M-BC - -R 0 M-BF - -R M-BJ - -R M-BC - -R 0 M-BF - -R M-BJ - -R M-BC - -R 0 M-BF - -R M-BJ - -R M-BC - -R 0 M-CF - -R M-CJ - -R M-CC - -R 00 M-CF - -J M-CJ - -J M-CC - -J 0 M-CF - -R M-CJ - -R M-CC - -R 0 M-CF - -R M-CJ - -R M-CC - -R 00 M-CF - -J M-CJ - -J M-CC - -J Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: M-BF - -R becomes M-BFB- -R. For other values, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: M-BJB- -R becomes M-BJB-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: M-BFB-R becomes M-BFB. Class H fuse clips can be supplied. Example: M-B -R becomes M-B -. Class J fuse clips can be supplied. Example: M-B -R becomes M-B -J. Class HRC form II fuse clips can be supplied. Example: M-B -R becomes M-B -E. -

83 Bulletin V NEM Combination Non-Reversing Starters Vacuum Disconnect Type Bulletin V NEM starter sizes Fusible or non-fusible disconnect switch Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW) Heater Elements Starters with eutectic alloy overload relay require heater elements. Located on page -. Max. Hp Rating Full Load Current Must Type R// Not Exceed Continuous Fuse Clip Rainproof, Type /X mpere Rating Rating Type R// Waterproof, Watertight mperes Type Rainproof, Dusttight Corrosion- Motor Voltage [] General Waterproof, (Door Safety Resistant 0 Hz 0 Hz 0 Hz 0 Hz Fuses not Purpose Dusttight Hardware) Stainless Steel NEM Size Continuous mpere Rating [] 00V 0V 0 V 0 V Line Voltage [V] included. Select per NEC V-E - -R V-EF - -R V-EJ - -R V-EC - -R V-E - -R V-EF - -R V-EJ - -R V-EC - -R V-E - -R V-EF - -R V-EJ - -R V-EC - -R V-E - -J V-EF - -J V-EJ - -J V-EC - -J V-E - -J V-EF - -J V-EJ - -J V-EC - -J V-F - -R V-FF - -R V-FJ - -R V-FC - -R V-F - -R V-FF - -R V-FJ - -R V-FC - -R V-F - -R V-FF - -R V-FJ - -R V-FC - -R V-GF - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: V-E - -R becomes V-EB- -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control B Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: V-EB- -R becomes V-EB-BM-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: V-EFB-R becomes V-EFB. Class H fuse clips can be supplied. Example: V-E -R becomes V-E -. Class J fuse clips can be supplied. Example: V-E -R becomes V-E -J. Class HRC form II fuse clips can be supplied. Example: V-E -R becomes V-E -E. 0 -

84 Bulletin NEM Combination Non-Reversing Starters Circuit Breaker Type 0 NEM Size Continuous mpere Rating [] 0 Bulletin NEM starter sizes 0 Overload relays: Eutectic supplied as standard, solid-state available as an option Circuit breaker magnetic only (instantaneous) Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Non-metallic enclosures: Type /X Hazardous location enclosures: Type & Modifications factory installed ccessories field installed Service entrance rated Bulletin combination non-reversing starter consists of a Bulletin 0 starter and a circuit breaker magnetic only (instantaneous trip) mounted in a common enclosure. Starters sizes & consists of a thermal magnetic (inverse time) circuit breaker. Heater Elements Starters with eutectic alloy overhead relays require heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications Circuit Breaker Versions culus Listed (File No. E, Guide No. NKJH, NKJH) Hazardous Locations culus Listed (File No. E, Guide No. NOTH, NOTH) merican Bureau of Shipping Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Non-metallic Motor Voltages 00V 0V 0V V 0 / 0 / F - - -J - - -C - - -S - - / / F - - -J - - -C - - -S - - -/ -/ -/ -/ F - - -J - - -C - - -S F - - -J - - -C - - -S / 0 / -B - - -BF - - -BJ - - -BC - - -BS - - / / 0 0 -B - - -BF - - -BJ - - -BC - - -BS - - -/ -/ -/ -/ -B - - -BF - - -BJ - - -BC - - -BS - - -B - - -BF - - -BJ - - -BC - - -BS - - -/ -/ -/ -/ -B BF BJ BC BS B - - -BF - - -BJ - - -BC - - -BS C - - -CF - - -CJ - - -CC - - -CS - - -C - - -CF - - -CJ - - -CC - - -CS C - - -CF - - -CJ - - -CC - - -CS - - Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: -B - - becomes -BB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -BB- becomes -BB-F-. To order starters (size 0 ) with current limiters, add the letter C at the end of the listed cat. no. Example: - - -C. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: -B - -V. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. -

85 Bulletin NEM Combination Non-Reversing Starters Circuit Breaker Type, Continued NEM Size Continuous mpere Rating [] Heater Elements Starters with eutectic alloy overhead relays require heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Hazardous Locations Type R// Rainproof, Waterproof, Dustlight Type R// Rainproof, Waterproof, Dustlight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Nonmetallic Type Motor Voltage General Purpose 00V 0V 0V V 0 -D - - -DF - - -DJ - - -DC - - -DS D - - -DF - - -DJ - - -DC - - -DS D - - -DF - - -DJ - - -DC - - -DS E - - -EF - - -EJ - - -EC - - -ES E - - -EF - - -EJ - - -EC - - -ES E - - -EF - - -EJ - - -EC - - -ES E - - -EF - - -EJ - - -EC - - -ES E - - -EF - - -EJ - - -EC - - -ES E EF EJ EC ES F - - -FF - - -FJ - - -FC - - -FS F - - -FF - - -FJ - - -FC - - -FS F FF FJ FC FS F - - -FF - - -FJ - - -FC - - -FS F - - -FF - - -FJ - - -FC - - -FS F - - -FF - - -FJ - - -FC - - -FS GF - -0T -GC - -0T -GF - -T -GC - -T 0 0 -GF - -T -GC - -T 00 -GF - -T -GC - -T 0 0 -GF - -T -GC - -T GF - -T -GC - -T 0 -GF - -T -GC - -T -GF - -T -GC - -T 0 -HF - -T 00 -HF - -T HF - -T HF - -T Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: -BU - - becomes -BU- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -BB- - becomes -BB-F-. For Type R applications, it is necessary that a drain or breather and drain fitting be added to the enclosure. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: -BU - -V. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. 0 -

86 Bulletin NEM Combination Non-Reversing Starters Circuit Breaker Type, Continued 0 NEM Size Continuous mpere Rating [] Heater Elements Starters with eutectic alloy overhead relays require heater elements. Located on page -. Maximum Horsepower Rating Hazardous Locations Full Load Current Must Not Exceed Continuous mpere Rating Unilock Enclosure Bolted Enclosure Motor Voltage Type R/ & Class I, Groups C & D Class II, Groups E, F & G Divisions & Type & Class I, Groups C & D Class II, Groups E, F & G Divisions & Type R/ & Class I, Groups C & D Class II, Groups E, F & G Divisions & 00V 0V 0V V 0 / 0 / -U - - -E - - -H - - / / 0 0 -U - - -E - - -H - - -/ -/ -/ -/ -U - - -E - - -H - - -U - - -E - - -H / 0 / -BU - - -BE - - -BH - - / / 0 0 -BU - - -BE - - -BH - - -/ -/ -/ -/ -BU - - -BE - - -BH - - -BU - - -BE - - -BH - - -/ -/ -/ -/ -BU BE BH BU - - -BE - - -BH CU - - -CE - - -CH - - -CU - - -CE - - -CH CU - - -CE - - -CH DU - - -DE - - -DH DU - - -DE - - -DH DU - - -DE - - -DH EU - - -EE - - -EH EU - - -EE - - -EH EU - - -EE - - -EH EU - - -EE - - -EH EU - - -EE - - -EH EU EE EH FU - - -FE - - -FH FU - - -FE - - -FH FU FE FH FU - - -FE - - -FH FU - - -FE - - -FH FU - - -FE - - -FH - - Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: -BU - - becomes -BU- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -BUB- - becomes -BUB-D-. For Type R applications, it is necessary that a drain or breather and drain fitting be added to the enclosure. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: -BU - -V. Includes drain and cover with gasket. NEM size Unilock enclosed starters have a continuous ampere rating of 0. Bolted enclosure suitable for use on motors from 00 HP, 0V. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. -

87 Bulletin H Horizontal Mounting Circuit Breaker Type Overview/Product Selection NEM Size Bulletin H Horizontal Mounting Combination Starter NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state available as an option Circuit breaker magnetic only (instantaneous) Painted metal enclosures: Type R// Modifications factory installed ccessories field installed Service entrance rated Bulletin H combination non-reversing starter consists of a Bulletin 0 starter and a circuit breaker magnetic only (instantaneous trip) mounted in a horizontal enclosure. Heater Elements Starters with eutectic alloy overhead relays require heater elements. Located on page -. Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltages Type R// Rainproof, Waterproof, Dusttight with Door Safety Hardware Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications Circuit Breaker Versions UL Listed (File No. E, Guide No. NKJH) CS (File No. LR) Hazardous Locations UL Listed (File No. E, Guide No. NOTH) CS (File No. LR) merican Bureau of Shipping Type R// Rainproof, Waterproof, Dusttight with Door Safety Hardware & External Overload Relay Reset 00V 0V 0V V Coil Voltage [V] 0 / H-BJH- H-BDH- / H-BJH- H-BDH- - / 0 H-BJH- H-BDH- H-BJH- H-BDH- -/ H-BJH-0 H-BDH-0 0 / H-BJ- H-BD- / H-BJ- H-BD- - 0 / H-BJ- H-BD- H-BJ-0 H-BD-0 0 H-BJB- H-BDB- - H-BJB- H-BDB- / 0 - H-BJB-0 H-BDB-0 / 0 H-BJB- H-BDB- 0 H-BJC- H-BDC- - H-BJC- H-BDC- / 00 - H-BJC-0 H-BDC-0 / 0 H-BJC- H-BDC- 0 0 H-CJH- H-CDH- 0 H-CJ- H-CD- 0 H-CJ- H-CD- H-CJB- H-CDB- 0 0 H-CJB- H-CDB- H-CJC- H-CDC H-CJC- H-CDC- When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. 0V Separate Control Starters with 0V separate control are available at listed prices. To order, add letter D after the third letter following the first dash in the listed cat. no. 0 -

88 Bulletin M NEM Combination Non-Reversing Starters with Extra Panel Space Circuit Breaker Type Bulletin M NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state available as an option Circuit breaker magnetic only (instantaneous trip) Painted metal extra capacity enclosures: Type, Type R// Stainless steel extra capacity enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Bulletin M combination non-reversing starter consists of a Bulletin 0 starter and a circuit breaker magnetic only (instantaneous trip) mounted in a common enclosure with extra panel space. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS., No. Certifications culus Listed (File No. E, Guide No. NKJH) 0 NEM Size Heater Elements Starters with eutectic alloy overload relay require overload heater elements. Located on page -. Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight, Corrosion-Resistant, Stainless Steel 00V 0V 0V V 0 / 0 / M-BF - - M-BJ - - M-BC - - / / 0 0 M-BF - - M-BJ - - M-BC - - -/ -/ -/ -/ M-BF - - M-BJ - - M-BC - - M-BF - - M-BJ - - M-BC - - -/ -/ -/ -/ M-BF - -0 M-BJ - -0 M-BC M-BF - - M-BJ - - M-BC M-CF - - M-CJ - - M-CC - - M-CF - - M-CJ - - M-CC M-CF - - M-CJ - - M-CC - - Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: M-BF - - becomes M-BFB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: M-BB- - becomes M-BB-D-. To order starters (size 0 ) with current limiters, add the letter C at the end of the listed cat. no. Example: M- - -C. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: M-B - -V. -

89 Bulletin V NEM Combination Non-Reversing Starters with Extra Panel Space Vacuum Circuit Breaker Type Bulletin V NEM starter sizes Circuit breaker magnetic inly (instantaneous) Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overhead relays require heater elements. Located on page -. Max. Hp Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Motor Voltages 00V 0V 0V V 0 V-E - -T V-EF - -T V-EJ - -T V-EC - -T 0 0 V-E - -T V-EF - -T V-EJ - -T V-EC - -T 0 V-E - -T V-EF - -T V-EJ - -T V-EC - -T 0 V-E - -T V-EF - -T V-EJ - -T V-EC - -T 0 V-E - -T V-EF - -T V-EJ - -T V-EC - -T V-E - -0T V-EF - -0T V-EJ - -0T V-EC - -0T 0 0 V-F - -T V-FF - -T V-FJ - -T V-FC - -T 0 V-F - -T V-FF - -T V-FJ - -T V-FC - -T 00 V-F - -0T V-FF - -0T V-FJ - -0T V-FC - -0T V-F - -T V-FF - -T V-FJ - -T V-FC - -T 0 V-F - -T V-FF - -T V-FJ - -T V-FC - -T V-F - -T V-FF - -T V-FJ - -T V-FC - -T 00 V-GF - -0T V-GF - -T 0 0 V-GF - -T 00 V-GF - -T 0 0 V-GF - -T V-GF - -T 0 V-GF - -T V-GF - -T Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: V-E - -T becomes V-EB- -T. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control B Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: V-EB-T becomes V-EB-BM-T. 0 -

90 Bulletin NEM Combination Multi-Speed Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) 0-0 Bulletin NEM starter sizes -speed separate winding, constant or variable torque -speed separate winding, constant horsepower -speed con. pole, single winding, constant or variable Torque -speed con. pole, single winding, constant horsepower Overload relays: Eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Bulletin combination multi-speed starter consists of a Bulletin 0 multi-speed starter and a disconnect switch (fused or non-fused) mounted in a common enclosure. -Speed Separate Winding, -Pole -Pole, Constant or Variable Torque (Constant Horsepower page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overhead relays require heater elements for each speed located on page -. Maximum Hp Rating FLC Must Not Exceed Continuous mpere Rating Motor Voltage Fuse Clip Rating mperes [] Type R// Rainproof, Type R// Rainproof, Waterproof, Dusttight Type /X Watertight Type /X Watertight 0 Hz 0 Hz 0 Hz 0 Hz 0 0 Line Voltage Fuses not included. Select per Type General Purpose Waterproof, Dusttight (Door Safety Hardware) Corrosion-Resistant Stainless Steel Corrosion-Resistant Non-metallic 00V 0V V V [V] NEC E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R -/ -/ E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R -/ -/ E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R -/ -/ E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R E-C - - -R E-CF - - -R E-CJ - - -R E-CC - - -R E-CS - - -R E-C - - -R E-CF - - -R E-CJ - - -R E-CC - - -R E-CS - - -R E-C - - -J E-CF - - -J E-CJ - - -J E-CC - - -J E-CS - - -J E-C - - -J E-CF - - -J E-CJ - - -J E-CC - - -J E-CS - - -J E-D - - -R E-DF - - -R E-DJ - - -R E-DC - - -R E-DS - - -R E-D - - -R E-DF - - -R E-DJ - - -R E-DC - - -R E-DS - - -R E-D - - -J E-DF - - -J E-DJ - - -J E-DC - - -J E-DS - - -J E-D - - -J E-DF - - -J E-DJ - - -J E-DC - - -J E-DS - - -J E-E - - -R E-EF - - -R E-EJ - - -R E-EC - - -R E-E - - -R E-EF - - -R E-EJ - - -R E-EC - - -R E-E - - -J E-EF - - -J E-EJ - - -J E-EC - - -J E-E - - -J E-EF - - -J E-EJ - - -J E-EC - - -J E-F - - -R E-FF - - -R E-FJ - - -R E-FC - - -R E-F - - -R E-FF - - -R E-FJ - - -R E-FC - - -R E-F - - -R E-FF - - -R E-FJ - - -R E-FC - - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: E-B - - -R becomes E-BB- - -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: E-BB- - -R becomes E-BB-D-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: E-BFB-R becomes E-BFB. Class H fuse clips can be supplied. Example: E-B - R becomes E-B -. Class J fuse clips can be supplied. Example: E-B - R becomes E-B - J. Class HRC form II fuse clips can be supplied. Example: E-B - R becomes E-B - E. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see page -. Table of Contents Modifications... - ccessories... - pproximate Dimensions... - Specifications... - Standards Compliance UL 0 CS C., No. Certifications Fusible Versions culus Listed (File No. E, Guide No. NKJH, NKJH) Non-Fusible Versions culus Listed (File No. E, Guide No. NLDX, NLDX)

91 Bulletin E NEM Combination Multi-Speed Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) -Speed Separate Winding, -Pole -Pole, Constant Horsepower (Constant or Variable Torque page -0) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overhead relays require heater elements for each overload. Located on page -. Maximum Hp Rating Full Load Current Must Not Fuse Clip Type R// Exceed Continuous Rating Rainproof, Type /X Type /X mpere Rating mperes Type R// Waterproof, Watertight Watertight [] Rainproof, Dusttight Corrosion- Corrosion- Motor Voltage Fuses not Type Waterproof, (Door Safety Resistant Resistant 0 Hz 0 Hz 0 Hz 0 Hz Line included. General Purpose Dusttight Hardware) Stainless Steel Non-metallic 0 0 Voltage Select per 00V 0V V V [V] NEC E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R -/ -/ E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R -/ -/ E-B - - -R E-BF - - -R E-BJ - - -R E-BC - - -R E-BS - - -R -/ E-C - - -R E-CF - - -R E-CJ - - -R E-CC - - -R E-CS - - -R E-C - - -R E-CF - - -R E-CJ - - -R E-CC - - -R E-CS - - -R -/ E-C - - -J E-CF - - -J E-CJ - - -J E-CC - - -J E-CS - - -J E-C - - -J E-CF - - -J E-CJ - - -J E-CC - - -J E-CS - - -J E-D - - -R E-DF - - -R E-DJ - - -R E-DC - - -R E-DS - - -R E-D - - -R E-DF - - -R E-DJ - - -R E-DC - - -R E-DS - - -R E-D - - -J E-DF - - -J E-DJ - - -J E-DC - - -J E-DS - - -J E-D - - -J E-DF - - -J E-DJ - - -J E-DC - - -J E-DS - - -J E-E - - -R E-EF - - -R E-EJ - - -R E-EC - - -R E-E - - -R E-EF - - -R E-EJ - - -R E-EC - - -R E-E - - -J E-EF - - -J E-EJ - - -J E-EC - - -J E-E - - -J E-EF - - -J E-EJ - - -J E-EC - - -J E-F - - -R E-FF - - -R E-FJ - - -R E-FC - - -R E-F - - -R E-FF - - -R E-FJ - - -R E-FC - - -R E-F - - -R E-FF - - -R E-FJ - - -R E-FC - - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: E-B - - -R becomes E-BB- - -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: E-BB- - -R becomes E-BB-D-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: E-BFB-R becomes E-BFB. Class H fuse clips can be supplied. Example: E-B - R becomes E-B -. Class J fuse clips can be supplied. Example: E-B - R becomes E-B - J. Class HRC form II fuse clips can be supplied. Example: E-B - R becomes E-B- - E. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see page -. Fusible Disconnect Type With Class R Fuse Clips and Non-Fusible Disconnect Type Heater Elements Starters with eutectic alloy overhead relays require heater elements for each speed. Located on page

92 0 Bulletin F NEM Combination Multi-Speed Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) -Speed Consequent Pole, -Pole -Pole, Single Winding, Constant or Variable Torque (Constant Horsepower page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overhead relays require heater elements for each speed. Located on page -. Maximum Hp Rating Full Load Current Must Not Fuse Clip Type R// Exceed Continuous Rating Rainproof, Type /X Type /X mpere Rating mperes Type R// Waterproof, Watertight Watertight [] Rainproof, Dusttight Corrosion- Corrosion- Motor Voltage Fuses not Type Waterproof, (Door Safety Resistant Resistant 0 Hz 0 Hz 0 Hz 0 Hz Line included. General Purpose Dusttight Hardware) Stainless Steel Non-metallic 0V 0 0 Voltage Select per 00V 0V V V [V] NEC -/ -/ F-B - - -R F-BF - - -R F-BJ - - -R F-BC - - -R F-BS - - -R F-B - - -R F-BF - - -R F-BJ - - -R F-BC - - -R F-BS - - -R -/ -/ F-B - - -R F-BF - - -R F-BJ - - -R F-BC - - -R F-BS - - -R F-B - - -R F-BF - - -R F-BJ - - -R F-BC - - -R F-BS - - -R F-C - - -R F-CF - - -R F-CJ - - -R F-CC - - -R F-CS - - -R F-C - - -R F-CF - - -R F-CJ - - -R F-CC - - -R F-CS - - -R F-C - - -J F-CF - - -J F-CJ - - -J F-CC - - -J F-CS - - -J F-C - - -J F-CF - - -J F-CJ - - -J F-CC - - -J F-CS - - -J F-D - - -R F-DF - - -R F-DJ - - -R F-DC - - -R F-DS - - -R F-D - - -R F-DF - - -R F-DJ - - -R F-DC - - -R F-DS - - -R F-D - - -J F-DF - - -J F-DJ - - -J F-DC - - -J F-DS - - -J F-D - - -J F-DF - - -J F-DJ - - -J F-DC - - -J F-DS - - -J F-E - - -R F-EF - - -R F-EJ - - -R F-EC - - -R F-E - - -R F-EF - - -R F-EJ - - -R F-EC - - -R F-E - - -J F-EF - - -J F-EJ - - -J F-EC - - -J F-E - - -J F-EF - - -J F-EJ - - -J F-EC - - -J F-F - - -R F-FF - - -R F-FJ - - -R F-F - - -R F-FF - - -R F-FJ - - -R F-F - - -R F-FF - - -R F-FJ - - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: F-B - - -R becomes F-BB- - -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: F-BB- - -R becomes F-BB-D-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: F-BJB-R becomes F-BJB. Class H fuse clips can be supplied. Example: F-B - R becomes F-B -. Class J fuse clips can be supplied. Example: F-B - R becomes F-B - J. Class HRC form II fuse clips can be supplied. Example: F-B - R becomes F-B - E. -

93 Bulletin G NEM Combination Multi-Speed Starters Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) -Speed Consequent Pole, -Pole -Pole, Single Winding, Constant Horsepower (Constant or Variable Torque page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overhead relays require heater elements for each speed. Located on page -. Maximum Hp Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type R// Rainproof, Type /X Type /X Fuse Clip Type R// Waterproof, Watertight Watertight Rating Rainproof, Dusttight Corrosion- Corrosion- 0 0 mperes Type Waterproof, (Door Safety Resistant Resistant Hz Hz 0 Hz 0 Hz [] General Purpose Dusttight Hardware) Stainless Steel Non-metallic V 0 0 Line Voltage Fuses not included. Select per V V V V [V] NEC G-B - - -R G-BF - - -R G-BJ - - -R G-BC - - -R G-BS - - -R -/ -/ G-B - - -R G-BF - - -R G-BJ - - -R G-BC - - -R G-BS - - -R G-B - - -R G-BF - - -R G-BJ - - -R G-BC - - -R G-BS - - -R -/ -/ G-B - - -R G-BF - - -R G-BJ - - -R G-BC - - -R G-BS - - -R - / G-C - - -R G-CF - - -R G-CJ - - -R G-CC - - -R G-CS - - -R G-C - - -R G-CF - - -R G-CJ - - -R G-CC - - -R G-CS - - -R - / G-C - - -J G-CF - - -J G-CJ - - -J G-CC - - -J G-CS - - -J G-C - - -J G-CF - - -J G-CJ - - -J G-CC - - -J G-CS - - -J G-D - - -R G-DF - - -R G-DJ - - -R G-DC - - -R G-DS - - -R G-D - - -R G-DF - - -R G-DJ - - -R G-DC - - -R G-DS - - -R G-D - - -J G-DF - - -J G-DJ - - -J G-DC - - -J G-DS - - -J G-D - - -J G-DF - - -J G-DJ - - -J G-DC - - -J G-DS - - -J G-E - - -R G-EF - - -R G-EJ - - -R G-EC - - -R G-ES - - -R G-E - - -R G-EF - - -R G-EJ - - -R G-EC - - -R G-E - - -J G-EF - - -J G-EJ - - -J G-EC - - -J G-E - - -J G-EF - - -J G-EJ - - -J G-EC - - -J G-F - - -R G-FF - - -R G-FJ - - -R G-F - - -R G-FF - - -R G-FJ - - -R G-F - - -R G-FF - - -R G-FJ - - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: G-B - - -R becomes G-BB- - -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: G-BB- - -R becomes G-BB-D-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: G-BJB-R becomes G-BJB. Class H fuse clips can be supplied. Example: G-B - R becomes G-B -. Class J fuse clips can be supplied. Example: G-B - R becomes G-B - J. Class HRC form II fuse clips can be supplied. Example: G-B - R becomes G-B - E. 0 -

94 Bulletin NEM Combination Multi-Speed Starters Circuit Breaker Type 0 Bulletin NEM starter sizes Circuit breaker magnetic only (instantaneous trip) -speed separate winding, constant or variable torque -speed separate winding, constant horsepower -speed consequent pole, single winding, constant or variable torque -speed consequent pole, single winding, constant horsepower Overload relays: Eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Bulletin combination multi-speed starter consists of a Bulletin 0 multi-speed starter and a circuit breaker magnetic only (instantaneous trip) mounted in a common enclosure. -Speed Separate Winding, -Pole -Pole, Constant or Variable Torque (Constant Horsepower page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overload relays require heater elements for each overload. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS., No. Certifications culus Listed (File No. E, Guide No. NLDX, NLDX) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Non-metallic Motor Voltage 00V 0V 0V V 0 / 0 / E-B E-BF E-BJ E-BC E-BS / / 0 0 E-B E-BF E-BJ E-BC E-BS / -/ -/ -/ E-B E-BF E-BJ E-BC E-BS / E-B E-BF E-BJ E-BC E-BS E-B E-BF E-BJ E-BC E-BS / -/ -/ -/ E-B E-BF E-BJ E-BC E-BS E-B E-BF E-BJ E-BC E-BS E-C E-CF E-CJ E-CC E-CS E-C E-CF E-CJ E-CC E-CS E-C E-CF E-CJ E-CC E-CS E-D E-DF E-DJ E-DC E-DS E-D E-DF E-DJ E-DC E-DS E-D E-DF E-DJ E-DC E-DS E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: E-B becomes E-BB For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: E-BB becomes E-BB-D-D-0. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, see [T-]. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: E-B V. State horsepower if less than listed. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. -

95 Bulletin E NEM Combination Multi-Speed Starters Circuit Breaker Type -Speed Separate Winding, -Pole -Pole, Constant Horsepower (Constant or Variable Torque page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overload relays require heater elements for each overload. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Non-mettalic Motor Voltage 00V 0V 0V V 0 / 0 / E-B E-BF E-BJ E-BC E-BS / / 0 0 E-B E-BF E-BJ E-BC E-BS / -/ E-B E-BF E-BJ E-BC E-BS / -/ E-B E-BF E-BJ E-BC E-BS E-B E-BF E-BJ E-BC E-BS E-B E-BF E-BJ E-BC E-BS / -/ E-B E-CF E-BJ E-BC E-BS / -/ E-C E-CF E-CJ E-CC E-CS E-C E-CF E-CJ E-CC E-CS E-C E-CF E-CJ E-CC E-CS E-C E-DF E-CJ E-CC E-CS E-D E-DF E-DJ E-DC E-DS E-D E-DF E-DJ E-DC E-DS E-D E-DF E-DJ E-DC E-DS E-D E-DF E-DJ E-DC E-DS E-D E-EF E-DJ E-DC E-DS E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-EF E-EJ E-EC E-E E-FF E-EJ E-EC E-F E-FF E-FJ G-FC E-F E-FF E-FJ G-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F E-FF E-FJ E-FC E-F G-FF E-FJ E-FC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: E-C becomes E-CB For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: E-BB becomes E-BB-D-D-0. These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, see page -. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: E-B V. State horsepower if less than listed. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. 0 -

96 0 Bulletin F NEM Combination Multi-Speed Starters Circuit Breaker Type, Continued -Speed Consequent Pole, Single Winding, -Pole -Pole, Constant or Variable Torque (Constant Horsepower Page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overload relays require heater elements for each overload. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Non-metallic Motor Voltage 00V 0V 0V V 0 / 0 / F-B F-BF F-BJ F-BC F-BS / / 0 0 F-B F-BF F-BJ F-BC F-BS / -/ -/ -/ F-B F-BF F-BJ F-BC F-BS F-B F-BF F-BJ F-BC F-BS F-B F-BF F-BJ F-BC F-BS / -/ -/ -/ F-B F-BF F-BJ F-BC F-BS F-B F-BF F-BJ F-CC F-CS F-C F-CF F-CJ F-CC F-CS F-C F-CF F-CJ F-CC F-CS F-C F-CF F-CJ F-DC F-DS F-D F-DF F-DJ F-DC F-DS F-D F-DF F-DJ F-DC F-DS F-D F-DF F-DJ F-EC F-E F-EF F-EJ F-EC F-E F-EF F-EJ F-EC F-E F-EF F-EJ F-EC F-E F-EF F-EJ F-EC F-E F-EF F-EJ F-EC F-E F-EF F-EJ F-FC F-F F-FF F-FJ F-FC F-F F-FF F-FJ F-FC F-F F-FF F-FJ F-FC F-F F-FF F-FJ F-FC F-F F-FF F-FJ F-FC F-F F-FF F-FJ F-FC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: F-B becomes F-BB For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: F-BB becomes F-BB-D-D-0. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: E-B V. State horsepower if less than listed. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. -

97 Bulletin G NEM Combination Multi-Speed Starters Circuit Breaker Type, Continued -Speed Consequent Pole, Single Winding, -Pole -Pole, Constant Horsepower (Constant or Variable Torque page -) NEM Size Continuous mpere Rating [] 0 0 Heater Elements Starters with eutectic alloy overload relays require heater elements for each overload. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Type /X Watertight Corrosion- Resistant Non-metallic Motor Voltage 00V 0V 0V V 0 / 0 / G-B G-BF G-BJ G-BC G-BS / / 0 0 G-B G-BF G-BJ G-BC G-BS / -/ G-B G-BF G-BJ G-BC G-BS / -/ G-B G-BF G-BJ G-BC G-BS G-B G-BF G-BJ G-B G-BF G-BJ G-BC G-BS / -/ G-B G-BF G-BJ G-BC G-BS / -/ G-C G-CF G-CJ G-CC G-CS G-C G-CF G-CJ G-CC G-CS G-C G-CF G-CJ G-CC G-CS G-C G-CF G-CJ G-CC G-CS G-D G-DF G-DJ G-DC G-DS G-D G-DF G-DJ G-DC G-DS G-D G-DF G-DJ G-DC G-DS G-D G-DF G-DJ G-DC G-DS G-D G-DF G-DJ G-DC G-DS G-E G-EF G-EJ G-E G-E G-EF G-EJ G-EC G-E G-EF G-EJ G-EC G-E G-EF G-EJ G-EC G-E G-EF G-EJ G-EC G-E G-EF G-EJ G-EC G-F G-FF G-FJ G-FC G-F G-FF G-FJ G-FC G-F G-FF G-FJ G-FC G-F G-FF G-FJ G-FC G-F G-FF G-FJ G-FC G-F G-FF G-FJ G-FC G-F G-FF G-FJ G-FC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: G-B becomes G-BB For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD - Overload Relay Code Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from page - to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Example: G-BB becomes G-BB-D-D-0. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: E-B V. State horsepower if less than listed. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. 0 -

98 Bulletin X NEM Pump Control Panels Disconnect Type (Fusible with Class R Fuse Clips) Bulletin X NEM starter sizes Fusible disconnect switch Painted metal extra capacity enclosures: Type R Overload relays: Eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Bulletin X (with fusible disconnect switch) consists of a Bulletin 0 starter mounted in an enclosure with extra panel space. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS., No. Certifications culus Listed (File No. E, Guide No. NKJH, NKJH) 0 NEM Size Heater Elements Starters with eutectic alloy overload relays require heater elements. Located on page -. Continuous mpere Rating [] 0 0 Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage 0 Hz 0 Hz 0 Hz 0 Hz Line Voltage [V] Fuse Clip Rating mperes [] Fuses not included. Select per NEC Type R Rainproof with Extra Panel Space 00V 0V 0 V 0 V -/ -/ X-BN - -R X-BN - -R -/ -/ X-BN - -R X-BN - -R X-CN - -R X-CN - -R X-CN - -J X-CN - -J X-DN - -R X-DN - -R X-DN - -J X-DN - -J X-EN - -R X-EN - -R X-EN - -J X-EN - -J X-FN - -R X-FN - -R X-GN - -R X-HN - -L Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: X-BN - - becomes X-BN- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: X-BN- - becomes X-BN-D-. For 0V and 0V Hp ratings, limit the maximum fuse sizing to % of motor full load current. -

99 Bulletin V NEM Vacuum Pump Control Panels Vacuum Circuit Breaker Type Bulletin V NEM starter sizes Painted metal extra capacity enclosures: Type R Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Continuous mpere Rating [] 0 Heater Elements Starters with eutectic alloy overload relays require heater elements. Located on page -. Max. Hp Rating Fuse Clip Full Load Current Must Not Exceed Continuous mpere Rating Rating mperes [] Type R Motor Voltage Line Fuses not Rainproof with Extra 0 Hz 0 Hz 0 Hz 0 Hz Voltage included. Panel Space 00V 0V 0 V 0 V [V] Select per NEC V-EN - -R V-EN - -R V-EN - -J V-EN - -J V-FN - -R V-FN - -R V-GN - -R Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: V-EN - -R becomes V-EN- -R. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control [V] B Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: V-EN- -R becomes V-EN-BM-R. For 0V and 0V Hp ratings, limit the maximum fuse sizing to % of motor full load current. 0 -

100 Bulletin X NEM Pump Control Panels Circuit Breaker Type Bulletin X NEM starter sizes Circuit breaker magnetic only (instantaneous trip) Painted metal enclosures: Type R Overload relays: Eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Bulletin X with circuit breaker magnetic only (instantaneous trip) consists of a Bulletin 0 starter mounted in an enclosure with extra panel space. Starter sizes & consist of a thermal magnetic (inverse time) circuit breaker. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW) 0 NEM Size Heater Elements Starters with eutectic alloy overload relays require heater elements. Located on page -. Continuous mpere Rating [] 0 Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type R Rainproof with Extra Panel Space 00V 0V 0V V 0 / 0 / X-BN - - / / 0 0 X-BN - - -/ -/ -/ -/ X-BN - - X-BN - - -/ -/ -/ -/ X-BN X-BN X-CN - - X-CN X-CN - - X-DN X-DN X-DN X-EN X-EN X-EN X-EN X-EN X-EN - -0 When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: X-BN - - becomes X-BNB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: X-BNB- - becomes X-BNB-D-. -00

101 Bulletin X NEM Pump Control Panels Circuit Breaker Type NEM Size Heater Elements Starters with eutectic alloy overload relays require heater elements. Located on page -. Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type R Rainproof with Extra Panel Space 00V 0V 0V V 0 0 X-FN X-FN X-FN - -0 X-FN X-FN X-FN X-GN - -0T X-GN - -T 0 0 X-GN - -T 00 X-GN - -T 0 0 X-GN - -T X-GN - -T 0 X-GN - -T X-GN - -T 0 X-HN - -T 00 X-HN - -T 0 00 X-HN - -T 0 00 X-HN - -T When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: X-BN - - becomes X-BNB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: X-BNB- - becomes X-BNB-D-. 0-0

102 Bulletin V NEM Vacuum Pump Control Panels Vacuum Circuit Breaker Type Bulletin V NEM starter size Circuit breaker magnetic only (instantaneous trip) Painted metal enclosures: Type R Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW) 0 NEM Size Heater Elements Starters with eutectic alloy overload relays require heater elements. Located on page -. Continuous mpere Rating [] 0 0 Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type R Rainproof with Extra Panel Space 00V 0V 0V V 0 V-EN - -T 0 0 V-EN - -T 0 V-EN - -T 0 V-EN - -T 0 V-EN - -T V-EN - -0T 0 0 V-FN - -T 0 V-FN - -T 00 V-FN - -0T V-FN - -T 0 V-FN - -T V-FN - -T 00 V-GN - -0T V-GN - -T 0 0 V-GN - -T 00 V-GN - -T 0 0 V-GN - -T V-GN - -T 0 V-GN - -T V-GN - -T Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: V-EN - -T becomes V-EN- -T. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control B Transformer Control (See page - Note) C, 0 Hz H B C 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: V-EN- -T becomes V-EN-BM-T. -0

103 Bulletin NEM Oil Well Pump Control Panels Circuit Breaker Type Bulletin Bulletin 00 NEM starter Hand-Off-uto selector switch luminum enclosure with extra panel space: Type R Easy operation flange-style handle Lightning arrestor Overload relays: Eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Circuit breaker magnetic only (instantaneous) Control transformer Manual overload reset mounted on inner door One pre-punched accessory port with removable plug Table of Contents Product Selection... this page Typical Wiring Diagram... this page pproxmate Dimensions... this page Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -BNB- becomes -BNB-E. Typical Wiring Diagram Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage 0V Type R Motor Voltage 00V 0 0 -BNB- -BNC- -CNB- -CNC DNB- -DNC ENB- -ENC- If additional panel space is required, refer to publication -BR00_-EN-P or consult your local Rockwell utomation sales office or llen-bradley distributor. pproxmate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing 0 Dimensions mm (inches) NEM Size B C D E F G 0 (0) (-/) (-/) (-/) (-/) 0 (/) () -0

104 Bulletin 0 NEM Reduced Voltage Starters Product Overview NEM Starters and Panels Type Bulletin 0 & & NEM Size Continuous mpere Rating Motor Voltage Enclosure Type PW PW PW PW PW Part winding reduced voltage starter Bulletin 0 Type, Type R// NEM Wye-Delta Starters and Panels Part winding reduced voltage combination starter/pump panel PW PW PW PW PW 0 00 V (0 0 Hp) Bulletin Type, R// Bulletin Type R Part winding reduced voltage combination starter/pump panel PW PW PW PW PW Bulletin Type, Type R// Bulletin Type R Disconnecting Means No disconnect Fusible disconnect Thermal magnetic circuit breaker Overload Relays Options Eutectic solid-state Standards UL 0 and CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) Product Selection Page -0 Page -0 Page -0 0 Type Bulletin 0 & & YD YD NEM Size YD YD YD Continuous mpere Rating Wye delta reduced voltage starter Wye delta reduced voltage combination starter/pump panel YD YD YD YD YD Wye delta reduced voltage combination starter/pump panel YD YD YD YD YD Motor Voltage 00 V (0 00 Hp) 00 V (. 00 Hp) 00 V (0 00 Hp) Enclosure Type Bulletin 0 Type, Type R// Bulletin Type, R// Bulletin Type R Bulletin Type, Type R// Bulletin Type R Disconnecting Means No disconnect Fusible disconnect Thermal magnetic circuit breaker Overload Relays Options Eutectic solid-state Standards UL 0 and CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) Product Selection Page -0 Page - Page - -0

105 Bulletin 0 NEM Reduced Voltage Starters Product Overview, Continued NEM utotransformer Starters and Panels Type Bulletin 0 & & utotransformer reduced voltage starter utotransformer reduced voltage combination starter/pump panel NEM Size utotransformer reduced voltage combination starter/pump panel Continuous mpere Rating 0 Motor Voltage 00 V (0 00 Hp) 00 V ( 00 Hp) 00 V (0 00 Hp) Enclosure Type Bulletin 0 Type, Type R// Bulletin Type, R// Bulletin Type R Bulletin Type, Type R// Bulletin Type R Disconnecting Means No disconnect Fusible disconnect Thermal magnetic circuit breaker Overload Relays Options Eutectic solid-state Standards UL 0 and CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) Product Selection Page - Page - Page - 0-0

106 Bulletin 0 NEM Reduced Voltage Starters Catalog Number Explanation Configuration of a Basic Starter The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. Example Catalog Number 0 L B D 0 a b c d e f a Bulletin Number Code Description 0 Part winding reduced voltage starter Part winding reduced voltage combination starter with disconnect switch Part winding reduced voltage combination starter with circuit bbreaker 0 Wye delta reduced voltage starter Wye delta reduced voltage combination starter with disconnect switch Wye delta reduced voltage combination starter with circuit breaker 0 utotransformer reduced voltage starter utotransformer reduced voltage combination starter with disconnect switch utotransformer reduced voltage combination starter with circuit breaker Wye delta reduced voltage pump panel with disconnect switch Wye delta reduced voltage pump panel with circuit breaker utotransformer reduced voltage pump panel with disconnect switch utotransformer reduced voltage pump panel with circuit breaker Part winding reduced voltage pump panel with disconnect switch Part winding reduced voltage pump panel with circuit breaker b Starter Size Suffix Code NEM Size C D E F G L YD or PW M YD or PW P YD or PW S YD or PW U YD or PW c Enclosure Code Code Type Type : general purpose painted enclosure with screw fasteners, external overload relay reset Type //: rainproof, watertight, dusttight, painted metal enclosure with F screw fasteners, external overload relay reset Type R: rainproof, painted metal extra N capacity enclosure with screw fasteners, external overload relay reset d Coil Voltage Votlage Line Coil Description Code Voltage [V] Voltage [V] H Common 0 0 Control 0 0 B (without a 0 0 C transformer) H 0 0 Transformer 0 0 B Control 0 0 C 00 0 HD Separate 0 0 D Control 0 0 BD (without a 0 0 CD transformer) 00 0 Code None See page - e Overload Relay Type Eutectic lloy Solid-State f Options See page - Note: When selecting a factory-installed control circuit transformer, use the transformer control coil voltage code to denote the transformer primary voltage. The transformer secondary voltage and starter coil will both be 0V C by default. Example: -LB-P-R will have a transformer with a 0V primary voltage, 0V secondary voltage, and a 0V starter coil voltage. 0-0

107 Bulletin 0 NEM Reduced Voltage Starters Overview/Product Selection Bulletin 0 NEM Part Winding Starters Starter sizes PW Overload relays: eutectic suppllied as standard, solid-state available as an option Painted metal enclosures: Type, Type R// Modifications factory installed ccessories field installed Bulletin 0 part winding starters are used with squirrel cage motors having two separate parallel motor windings. Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Type R// Continuous mpere Rating Continuous Type Rainproof, watertight, mpere Rating Motor Voltage General Purpose dusttight NEM Size [] 00V 0V 0 V PW L LF - - PW M MF - - PW P PF - - PW S SF - - PW U UF - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-L - - becomes 0-LB- -. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-LB- - becomes 0-LB-D- D. 0-0

108 Bulletin & NEM Part Winding Combination Starters and Pump Panels Disconnect Type (Fusible with Class R Fuse Clips) Bulletin & Starter sizes PW Fusible disconnect switch Painted metal enclosure: Type (Bul. ), Type R// (Bul. ) Painted metal extra capacity enclosure: Type R (Bul. ) Overload relays: eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) 0 NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Continuous mpere Rating [] PW PW 0 PW 0 PW 0 PW 0 Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, watertight, dusttight Type R Rainproof with extra panel space Motor Voltage Fuse 00V 0V 0V V Rating [] 0 -L - - -R -LF - - -R -LN - - -R L - - -R -LF - - -R -LN - - -R 0 0 -M - - -R -MF - - -R -MN - - -R M - - -R -MF - - -R -MN - - -R M - - -J -MF - - -J -MN - - -J P - - -R -PF - - -R -PN - - -R P - - -J -PF - - -J -PN - - -J S - - -R -SF - - -R -SN - - -R S - - -J -SF - - -J -SN - - -J U - - -R -UF - - -R -UN - - -R U - - -J -UF - - -J -UN - - -J Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: -LN - - -R becomes -LNB- - -R. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page -0 Note) C, 0 Hz H B C 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -LNB- - -R becomes -LNB-D-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: -MFB-R becomes -MFB. -0

109 Bulletin & NEM Part Winding Combination Starters and Pump Panels Circuit Breaker Type Bulletin & Starter sizes PW Circuit breaker thermal magnetic (inverse time) Painted metal enclosure: Type (Bul. ), Type R// (Bul. ) Painted metal extra capacity enclosure: Type R (Bul. ) Overload relays: eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Continuous mpere Rating [] PW PW 0 PW 0 PW 0 PW 0 Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Enclosure Type R// General Purpose Enclosure Type R General Purpose Enclosure 00V 0V 0...V L - - -T -LF - - -T -LN - - -T -L - - -T -LF - - -T -LN - - -T -M - - -T -MF - - -T -MN - - -T M - - -T -MF - - -T -MN - - -T -M - - -T -MF - - -T -MN - - -T 0 -M - - -T -MF - - -T -MN - - -T 0 -M - - -T -MF - - -T -MN - - -T -P - - -T -PF - - -T -PN - - -T 0 0 -P - - -T -PF - - -T -PN - - -T 0 0 -P - - -T -PF - - -T -PN - - -T 0 0 -P - - -T -PF - - -T -PN - - -T 0 -P - - -T -PF - - -T -PN - - -T -P - - -T -PF - - -T -PN - - -T 0 -S - - -T -SF - - -T -SN - - -T 0 0 -S - - -T -SF - - -T -SN - - -T -S - - -T -SF - - -T -SN - - -T 00 -S T -SF T -SN T -S - - -T -SF - - -T -SN - - -T 0 -S - - -T -SF - - -T -SN - - -T U T -UF T -UN T -U - - -T -UF - - -T -UN - - -T 0 0 -U - - -T -UF - - -T -UN - - -T 00 -U - - -T -UF - - -T -UN - - -T 0 -U - - -T -UF - - -T -UN - - -T 00 -U - - -T -UF - - -T -UN - - -T 0 -U - - -T -UF - - -T -UN - - -T When controlling high-efficiency motors, please contact your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker and starter selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: -L - - -T becomes -LB- - -T. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -LB- - -T becomes -LB-F-F-T. 0-0

110 Bulletin 0 NEM Wye-Delta Starters Open Type, Disconnect Switch Type, and Circuit Breaker Type Bulletin 0 NEM Wye-Delta Starters Starter sizes YD Open circuit transition Overload relays: eutectic supplied as standard, solid-state available as an option Painted metal enclosures: Type, Type R// Modifications factory installed ccessories field installed Bulletin 0 wye-delta starters are used with delta-wound squirrel cage motors which have all leads brought out to facilitate a wye connection for reduced voltage starting. Table of Contents Modifications... - ccessories... - pproximate Dimensions... - Specifications... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Open Circuit Transition Type R// Rainproof, watertight, dusttight Open Circuit Transition Continuous NEM Size mpere Rating [] 00V 0V 0 V YD L - 0-LF - YD M - 0-MF - YD P - 0-PF - YD S - 0-SF - YD U - 0-UF - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-L - becomes 0-LB-. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-LB- becomes 0-LB-D. 0-0

111 Bulletin & NEM Wye-Delta Starters and Pump Panels Disconnect Type with Class R Fuses Bulletin & Starter sizes PW Fusible disconnect switch Painted metal enclosure: Type (Bul. ), Type R// (Bul. ), Type R (Bul. ) Overload relays: eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - pproximate Dimensions... - Specifications... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Continuous mpere Rating [] YD YD YD YD YD Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Open Circuit Transition Type R// Rainproof, watertight, dusttight Open Circuit Transition Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: -L - -R becomes -LB- -R. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) D D CD CD Type R Rainproof with extra panel space Open Circuit Transition Motor Voltage Fuse Rating 00V 0V 0V V [].. 0 -L - -R -LF - -R -LN - -R L - -R -LF - -R -LN - -R 0 0 -M - -R -MF - -R -MN - -R 0 0 -M - -R -MF - -R -MN - -R M - -R -MF - -R -MN - -R P - -R -PF - -R -PN - -R P - -J -PF - -J -PN - -J S - -R -SF - -R -SN - -R S - -J -SF - -J -SN - -J U - -R -UF - -R -UN - -R U - -J -UF - -J -UN - -J Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -LB- -R becomes -LB-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: -MFB-R becomes -MFB. 0 -

112 Bulletin & NEM Wye-Delta Combination Starters and Pump Panels Circuit Breaker Type Bulletin & Starter sizes YD Circuit breaker thermal magnetic (inverse time) Painted metal enclosure: Type (Bul. ), Type R// (Bul. ), Type R (Bul. ) Overload relays: eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - pproximate Dimensions... - Specifications... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) 0 NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Type R// Type R Must Not Exceed Type Rainproof, watertight, Rainproof with extra panel Continuous mpere Rating General Purpose dusttight space Continuous mpere Rating [] YD YD YD YD YD Motor Voltage Open Circuit Transition Open Circuit Transition Open Circuit Transition 00V 0V 0 V L - -T -LF - -T -LN - -T -L - -T -LF - -T -LN - -T -M - -T -MF - -T -MN - -T M - -T -MF - -T -MN - -T -M - -T -MF - -T -MN - -T 0 -M - -T -MF - -T -MN - -T 0 -M - -T -MF - -T -MN - -T -P - -T -PF - -T -PN - -T 0 0 -P - -T -PF - -T -PN - -T 0 0 -P - -T -PF - -T -PN - -T 0 0 -P - -T -PF - -T -PN - -T 0 -P - -T -PF - -T -PN - -T -P - -T -PF - -T -PN - -T 0 -S - -T -SF - -T -SN - -T 0 0 -S - -T -SF - -T -SN - -T -S - -T -SF - -T -SN - -T 00 -S - -0T -SF - -0T -SN - -0T -S - -T -SF - -T -SN - -T 0 -S - -T -SF - -T -SN - -T -U - -T -UF - -T -UN - -T U - -0T -UF - -0T -UN - -0T -U - -T -UF - -T -UN - -T 0 0 -U - -T -UF - -T -UN - -T 00 -U - -T -UF - -T -UN - -T 0 -U - -T -UF - -T -UN - -T 00 -U - -T -UF - -T -UN - -T When controlling high efficiency motors please contact your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker and starter selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: -L - -T becomes -LB- -T. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -LB- -T becomes -LB-D-T. -

113 Bulletin 0 NEM utotransformer Starters Open and Enclosed Type Bulletin 0 NEM utotransformer Starters Starter sizes Overload relays: eutectic supplied as standard, solid-state available as an option Painted metal enclosure: Type, Type R// Modifications factory installed ccessories field installed Bulletin 0 autotransformer starters provide the highest starting torque per ampere of line current which makes it an effective means of motor starting where the inrush current must be reduced with a minimum sacrifice of starting torque. Table of Contents Modifications... - ccessories... - Dimensions... - Specifications... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Type R// Rainproof, Watertight, Dusttight 00V 0V 0...V 0 0-C CF C CF C CF D DF D DF D DF D DF E EF E EF E EF E EF F FF F FF F FF F FF F FF G GF G GF G GF G GF G GF G GF G GF - - Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0-C - - becomes 0-CB- -. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: 0-CB- - becomes 0-CB-D-. 0 -

114 Bulletin & NEM utotransformer Combination Starters & Pump Panels Disconnect Type (Fusible with Class R Fuse Clips) Bulletin & Starter sizes Fusible disconnect switch Painted metal enclosure: Type (Bul. ), Type R// (Bul. ), Type R (Bul. ) Overload relays: eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Dimensions... - Specifications... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) 0 NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Type R// Rainproof, watertight, dusttight Type R Rainproof with extra panel space Fuse Rating 00V 0V 0...V [] C - -R -CF - -R -CN - -R 0 0 -C - -R -CF - -R -CN - -R 0 0 -D - -R -DF - -R -DN - -R D - -R -DF - -R -DN - -R 0 -E - -R -EF - -R -EN - -R E - -R -EF - -R -EN - -R E - -J -EF - -J -EN - -J F - -R -FF - -R -FN - -R F - -J -FF - -J -FN - -J 00 -G - -R -GF - -R -GN - -R G - -R -GF - -R -GN - -R GF - -J -GF - -J -GN - -J Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: -C - -R becomes -CB- -R. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) D D CD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -CB- -R becomes -CB-D-R. Non-Fusible Disconnect Type Cat. nos. listed above include a fusible disconnect switch with Class R fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: -DFB-R becomes -DFB. -

115 Bulletin & NEM utotransformer Combination Starters & Pump Panels Circuit Breaker Type Bulletin & Starter sizes Circuit breaker thermal magnetic (inverse time) Painted metal enclosure: Type (Bul. ), Type R// (Bul. ), Type R (Bul. ) Overload relays: eutectic supplied as standard, solid-state available as an option Modifications factory installed ccessories field installed Service entrance rated Table of Contents Modifications... - ccessories... - Dimensions... - Specifications... - Standards Compliance UL 0 CS C. No. Certifications culus Listed (File No. E, Guide No. NITW) NEM Size Heater Elements Starters with eutectic alloy overload relays require overload heater elements. Located on page -. Continuous mpere Rating [] Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Motor Voltage Type General Purpose Type R// Rainproof, watertight, dusttight Type R Rainproof with extra panel space 00V 0V 0...V 0 -C - -T -CF - -T -CN - -T -C - -T -CF - -T -CN - -T -C - -T -CF - -T -CN - -T -D - -T -DF - -T -DN - -T -D - -T -DF - -T -DN - -T 0 0 -D - -T -DF - -T -DN - -T 0 -D - -T -DF - -T -DN - -T 0 -E - -T -EF - -T -EN - -T 0 -E - -T -EF - -T -EN - -T 0 -E - -T -EF - -T -EN - -T 00 -E - -0T -EF - -0T -EN - -0T 0 -F - -T -FF - -T -FN - -T -F - -T -FF - -T -FN - -T 00 -F - -0T -FF - -0T -FN - -0T 0 -F - -T -FF - -T -FN - -T 00 -F - -T -FF - -T -FN - -T 00 -G - -0T -GF - -0T -GN - -0T -G - -T -GF - -T -GN - -T 0 0 -G - -T -GF - -T -GN - -T 00 -G - -T -GF - -T -GN - -T 0 -G - -T -GF - -T -GN - -T 00 -G - -T -GF - -T -GN - -T 00 -G - -T -GF - -T -GN - -T When controlling high efficiency motors please contact your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: -C - -T becomes -CB-T. For other voltages, please contact your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control C, H B C Transformer Control (See page -0 Note) 0 Hz 0V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: -CB- -T becomes -CB-H-T. 0 -

116 Bulletin 00 Line Modifications Factory Installed NEM Non-Combination Contactors/Starters For Use on Bulletins 00, 00F, 00L, 00LP, 0, 0V, 0, 0, and 0V Listed on this and the following pages are factory-installed modifications and special features that are available for the low voltage (00V maximum) contactors/starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product cat. no. Example: 0-BD-E-. 0 Bulletin 00 Size Rating 0 Bulletin 00L mpere Rating / Description of Modification Suffix No. Enclosure Type Pilot Devices in Cover or Flange Full Voltage Non-Reversing Single Speed Contactors or Starters (Buls. 00, 00F, 00L, 00LP, 0) STRT-STOP Push Button I/O (Canada only) ON-OFF Push Button HND-OFF-UTO Selector Switch OFF-ON Selector Switch E E E E E E E E R//, /X Bolted Unilock R/, /X, X Bolted Unilock R/, /X, X Bolted Unilock R/, /X, X Bolted Unilock NEM Size 00 0 HND-OFF-UTO Selector Switch (For Permanent Magnet Latch Type Contactor Only) ll Listed N N N N N PILOT LIGHT (Red Lens) R, R/, /X, X N PUSH-TO-TEST PILOT LIGHT (Red Lens) Full Voltage Reversing and Multi-Speed Starters (Buls. 0V, 0V, 0V, 0V) FOR-REV-STOP Push Button FOR-OFF-REV Selector Switch HIGH-LOW-STOP Push Button HIGH-OFF-LOW Selector Switch R R R R Bolted Unilock, R/, /X, X Bolted, R/, /X, X Bolted Unilock, R/, /X, X Bolted Unilock, R/, /X, X Bolted, R/, /X, X Bolted HIGH-LOW-OFF-UTO Selector Switch J, R/, /X, X N PILOT LIGHTS () R, R/, /X, X N = vailable N = Not vailable Bulletin 00L and 00FL require a normally open auxiliary contact when used with a push button. See page -. Only one push button or one selector switch (not both) may be added to a Bulletin 0 for NEM Type without transformers. Only one pilot light may be added to a Bulletin 0 Type without transformers. Bolted suitable for Type & or Type R, &. Unilock suitable for Type & or Type R, & with the addition of a drain or breather and drain. OFF pilot lights for non-reversing and non-multi-speed applications require a normally closed auxiliary contact add - to Red and amber are the only colors available on Type non-combination starters. On Type R/ non-combination starters, specify other lens colors by changing the letter to: = mber; B = Blue; C = Clear; G = Green; W = White. For multi-speed and reversing starters, one pilot light for each contactor. dd additional letters to identify two lens colors. The first letter specifies FORWRD, HIGH, or ON; the second letter specifies REVERSE, LOW, or OFF; e.g., G. N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N -

117 Bulletin 00 Line Modifications Factory Installed NEM Combination Contactors/Starters For Use on Bulletins 00, 00F, 00L, 00LP, 0, 0V, 0, 0, and 0V, Continued Control Circuit Transformer Description of Modification Includes primary fuses and secondary fuse with standard capacity 0 or 0 Hz With 00 W extra capacity 0 or 0 Hz Suffix No. P P P XP XP XP Enclosure Type, R/, /X, X Bolted Unilock, R/, /X, X Bolted Unilock NEM Size 00 0 Control Circuit uxiliary contact installed on contactor N.O. N.C. 0 ll listed ll listed N N Fused control circuit for applications less transformer ( Fuse Fuse Included) ( Fuses Fuses Included), R/, /X, X, R/, /X, X N N N N N N N N N N Surge suppression for 0 or 0V C Coil ll listed N N N N N Terminal blocks ( -C or similar) per block, R/, /X, X N N N N DC operation of control circuit (power circuit remains C) dd letters DC to Bulletin No. (add per solenoid) Overload Relays (Eutectic lloy) N.O. alarm contact adder N.C. alarm contact adder Omit overload relays (Bulletin ) (Bulletin ) (For Bulletins 0 and 0 only) Open, /X, X, ll listed ll listed ll listed uxiliary Relays (Indicate Contact rrangement and Coil Voltage) Ø Powermonitor (Timemark Model ) 00, R/, /X, X N N N N N Control relay (-pole maximum) ddition of timing relay (Line voltage monitor) dd Bulletin S (Line current monitor) Bulletin (used on Bulletin 00 0, -pole maximum) (Coil - 0 s timing range) ON Delay OFF Delay Extra strong coil for addition of power pole adders required for sizes B, R/ /X, X Unilock, R/ /X, X Unilock Open Type Open Type N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N STD STD STD STD STD STD N N N N N N N N STD N N STD N N N N N N N N N N N N N N N STD N N STD N N N N N N N N N N N N N N N STD N N STD N N ll listed N N N N N N N N Form compelling relay (used on Bulletin 0) 0, R/, /X, X N N N N Form B auto. seq. accelerating relay for each higher speed -controls the sequence of acceleration from low to high speed. (Used on Bulletin 0), R/, /X, X N N N N Form C auto. seq. decelerating relay for each lower speed -interposes a time delay between each lower speed. (Used on Bulletin 0), R/, /X, X N N N N Enclosure Breather Bolted N N N N N Breather and drain Unilock and Bolted N N N N N Drain Unilock and Bolted N N N N N Protective Covers for Contactors and Starters, R/, /X, N N N N N N N N N N N N N N N N N N = vailable N = Not vailable STD = Standard If the transformer secondary is to be grounded, add the suffix letter G at no aditional charge. Example: GP. When ordering in Canada, use suffix. Primary fusing is not required by the Canadian Electrical Code. Bolted suitable for Type & or Type R, &. Unilock suitable for Type & or Type R, &. Multiple auxiliary contacts are to be group coded: e.g. use followed by second digit for each auxiliary used: 0-- group coded to 0. Maximum quantity of auxuliary contacts (any type) group coded shall be. For Bulletins 0 and 0 devices, one auxiliary contact is installed on each of the two contactors. Order by description. Contactors provided on short mounting plate, please contact your local Rockwell utomation sales office or llen-bradley distributor for dimensions. Only one relay per starter. Through control wiring the starter is forced to operate in the low speed before switching to high speed. 0 -

118 0 Bulletin 00 Line Modifications Factory Installed NEM Combination Contactors/Starters For Use on Bulletins 0, 0L, 0, 0L, 0, 0X, 0, 0X,, H, M, V,, H, M, V,, E, F, G,, E, F, G, 0,,, 0,,, 0,,,,,,, X, V, X, and V Description of Modification Pilot Devices in Cover or Flange Full Voltage Non-Reversing Single Speed Starters Full Voltage Reversing and Multi-Speed Starters STRT-STOP push button ON-OFF push button STRT-STOP illuminated push button HND-OFF-UTO selector switch OFF-ON selector switch HND-UTO selector switch PILOT LIGHT PUSH-TO-TEST PILOT LIGHT Transformerincandescent bulb Transformer Type incandescent bulb STRT-STOP push button and HND-OFF-UTO selector switch (unwired) FOR-REV-STOP push button FOR-OFF-REV selector switch (Bulletin 0 0) HND-UTO Suffix No. E E E E L L E E E E H H H H Enclosure Type R//, /X Bolted Unilock R//, /X Bolted Unilock R//, /X R//, /X Bolted Unilock R//, /X Bolted Unilock R//, /X Bolted Unilock, R//, /X, R Bolted Unilock NEM Size 0 Transformer TypeLED bulb L, R//, /X, R, R//, /X, R Bolted N N N N N N N N N N N N N N N N N N N L, R//, /X, R R//, /X Bulletin 0 0, R//, /X N N Bulletin 0 Bolted ( & ) N N H H H H, R/X, /X, R Bolted Unilock R//, /X, Bolted Unilock HIGH-LOW- Bulletin, R//, /X N N STOP push button Bulletin Bolted N N HIGH-OFF-LOW Bulletin, R//, /X N N selector switch Bulletin Bolted N N HIGH-LOW-OFF-UTO selector switch J, R//, /X N N Transformer Type PILOT LIGHT () Incandescent Bulb, R//, /X N N Transformer TypeLED Bulb L, R//, /X N N PUSH-TO-TEST PILOT LIGHT Transformer Incandescent Bulb, R//, /X N N TransformerLED Bulb L*, R//, /X N N OFF pilot lights for non-reversing and non-multi-speed applications require a normally closed auxiliary contact (-). The suffix number is incomplete. Specify the lens with the following letters: = mber; B = Blue; C = Clear; G = Green; W = White. For multi-speed and reversing starters, one pilot light for each container. dd additional letter to identify two lens colors. The first letter specifies FORWRD or HIGH, or ON ; the second letter specifies REVERSE or LOW, or OFF ; e.g. G. = vailable, N = Not vailable N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N -

119 Bulletin 00 Line Modifications Factory Installed NEM Combination Contactors/Starters For Use on Bulletins 0, 0L, 0, 0L, 0, 0X, 0, 0X,, H, M, V,, H, M, V,, E, F, G,, E, F, G, 0,,, 0,,, 0,,,,,,, X, V, X, and V, Continued Control Circuit Transformers Includes Primary Fuses and Secondary Fuse uxiliary Contacts Control Circuit Overload Relays (Eutectic lloy) ccessories Description of Modification With standard capacity, 0 or 0 Hz With standard capacity with fuse covers With standard capacity, 0 or 0 Hz With standard capacity, 0 or 0 Hz With 00 W extra capacity, 0 or 0 Hz With 00 W extra capacity with fuse covers With 00 W extra capacity, 0 or 0 Hz With 00 W extra capacity, 0 or 0 Hz With 00V capacity With 00V capacity with fuse covers With 00 W extra capacity, 0 or 0 Hz With 00 W extra capacity with fuse covers With 00 W extra capacity, 0 or 0 Hz With 00 W extra capacity with fuse covers With 00 W extra capacity, 0 or 0 Hz With 00 W extra capacity with fuse covers uxiliary contact installed on contactors uxiliary contact contactor (four maximum) N.C. late break uxiliary contact installed on disconnect uxiliary contact installed on circuit breaker (external to breaker) to operate with handle (two maximum) Control circuit fuse block less transformer N.O. N.C. N.O. N.C. N.O. N.O. N.O. N.C. N.C. N.C. Fuse Fuse Included Fuse with Protective Cover Fuse Included Fuses Fuses Included Fuse with Protective Cover Fuse Included Suffix No. P PC P P XP XPC XP XP XXP XXPC YP YPC XYP XYPC YYP YYPC 0 Enclosure Type, R/X/, /X, R, R/X/, /X, R Bolted Unilock, R/X/, /X, R, R/X/, /X, R Bolted Unilock, R/X/, /X, R, R/X/, /X, R, R/X/, /X, R, R/X/, /X, R, R/X/, /X, R, R/X/, /X, R, R/X/, /X, R, R/X/, /X, X, R/X/, /X Bolted NEM Size 0 N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N, R//, /X, R N N, R//, /X, R, R//, /X, R, R/X/, /X, R Bolted Unilock, R/X/, /X, R Bolted Unilock N N N N, R/X/, /X, R C, R/X/, /X, R, R/X/, /X, R C, R/X/, /X, R Surge suppression for 0V or 0V C Coil, R/X/, /X, R Bolted Unilock N N Terminal blocks (Cat No. -HC) -Point Block TB, R/X/, /X, R Terminal blocks (Cat No. -HC) -Point Block TB, R/X/, /X, R N.O. alarm contact adder (Bulletin ), R/X/, /X, R N N N.C. alarm contact adder (Bulletin ) Bolted Unilock N N Omit three overload relays For Bulletins 0, 0X, 0, 0X Deduct For Bulletins, Deduct -phase Powermonitor (Timemark Model ) 00, R/X/, /X, R Bulletin (used on Bulletin 00 0), -pole maximum On Delay Off Delay B Bolted (R, & ) Unilock ( & ) N N N N, R/X/, /X, R N N Bolted Unilock N N Form compelling relay (used on Bulletin ) 0, R//, /X N N Form B auto. seq. accelerating relay for each higher speed (used on Bulletin ), R//, /X N N Form C auto. seq. decelerating relay for each higher speed (used on Bulletin ), R//, /X N N Bolted suitable for Type & or Type R, &. Unilock suitable for Type & or Type R, & with the addition of a drain or a breather and drain. White LED option not available, incandescent only. For Bulletins 0, 0, and devices. One auxiliary contact is installed on each of the two contactors. = vailable, N = Not vailable N N N N - 0

120 Bulletin 00 Line Modifications Factory Installed NEM Combination Contactors/Starters For Use on Bulletins 0, 0L, 0, 0L, 0, 0X, 0, 0X,, H, M, V,, H, M, V,, E, F, G,, E, F, G, 0,,, 0,,, 0,,,,,,, X, V, X, and V, Continued Circuit Breakers ccessories Suffix NEM Size Description of Modification No. Enclosure Type 0 Marine Requirements N N dd the letter C to the Current Limiters instantaneous circuit breaker no. C, R/X/, /X, R N N code. Thermal Magnetic Circuit Breakers dd the letter T to the circuit breaker no. code. T, R/X/, /X, R S S Current Limiters dd the letter D to the inverse time circuit breaker no. code. D, R/X/, /X, R N N Breather Bolted N N Enclosure Breather and drain Unilock and Bolted N N Drain Bolted and Unilock N N Enclosure Door Viewing Window 0W, R//, R N N Handles For Disconnect Switch or Circuit Breaker Fuse Cover Control Relay (Plug-In) Timing Relay (Plug-In) Electrical Interlock Painted metal Stainless steel Molded plastic (deduct) Protective fuse cover for disconnect switch -Pole -Pole On-Delay Off-Delay Early Break ( N.O. and N.C.) Early Break ( N.O. and N.C.), R//, R /X, R//, /X, R S S N S S N, R//, /X, R N N 0, R//, /X, R, R//, /X, R, R//, /X, R, R//, /X, R Bracket Mounting Feet for Pump Panels R N N N Elapsed Time Meter (ENM - Series T0) R N Protective Covers for Contactors and Starters, R/, /X, N N N Bolted suitable for Type & or Type R,, &. Unilock suitable for Type & or Type R,, & with the addition of a drain or a breather and drain. = vailable, N = Not vailable, S = Standard N N S S N N N 0-0

121 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Contactor ccessories For use on Bulletins 00, 00F, 00L, 00FL, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V Description Note: For complete listing of coils available, see page - NEM Size Coils (0 Hz) 0V CB- 00 0V CB- 0 0V 0 CB- 0 0V CB- 00V CB- 0V CC- 00 0V CC- 0 0V CC- 0 0V CC- 00V CC- 0V CD- 00 0V CD- 0 0V CD- 0 0V CD- 00V CD- 0V CE- 00 0V CE- 0 0V CE- 0 0V CE- 00V CE- 0V F- 00 0V F- (SER. 0 0V L) F- 0 0V F- 00V F- Surge Suppressor Made to be easily mounted directly across the coil terminals of contactors and starters with 0V or 0V C coils. The purpose of the suppressor is to limit voltage transients for applications requiring interface with solid-state components. One suppressor is required per coil. RC Module C Operating Mechanism 00-FSC V C, 0/0 Hz V C, 0/0 Hz 00-FSC0 0 0V C, 0/0 Hz 00-FSC0 Varistor Module C/DC Operating 00-FSV Mechanism V C/ V DC FSC0 V C/ 0V DC 00-FSV V C/ 0V DC 00-FSV V C 00-FSV 0V C -K0 0 V C 0 Varistor -K0 0V C -FSM 0V C Varistor -GSM -K0 0V C 00-N For non-combination starters only. For use on the interposing relay. For use on the contactor or starter. Description Terminal and Lug Covers Line side terminal covers Line side terminal covers (reversing) Line side lug covers (set of ) Line side lug covers (set of ) Tie Point Terminal NEM Size 0 -TC0N -TCN -TCN -TCN -TCN 0 -TC0R -LC--L -LC--L -LC--L -LC--T -LC--T -LC--T 0 -TP0 -TP Description For Use With No. of Poles NEM Size Protective Covers -PS0 00F/FL, 00L, 00LP, 0 -PC0 0 0, 0, 0E (), 0 -PS0 0F/G 00L, 00LP 0 -PC0-0F/G 0 -PS0-00F/FL, 00L, 00LP, -PC 0 0, 0, 0E (), -PS 0F/G 00L, 00LP -PC- 0F/G -PS- 00F/FL, 00L, 00LP, -PC 0 0, 0, 0E (), -PS 0F/G 00L, 00LP -PC- 0F/G -PS- 00F/FL, 00L, 00LP, -PC 0 0, 0, 0E (), -PS 0F/G 00L, 00LP -PC- 0F/G -PS- 00F/FL, 00L, 00LP -PC 0 -PS Used on -pole contactors and starters. Bul. Eutectic alloy or solid-state overload relays. 0 -

122 0 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Contactor ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X and V, Continued Timer ttachment Kit pneumatic timer attachment may be field installed in the space of two adjacent auxiliary contact blocks. Timing units are available for either ON-Delay or OFF-Delay operation with a timed set of one () N.O. and one () N.C. snap-action contacts that are electrically isolated. Repetitive accuracy within the timer range is approximately ±0% provided a minimum reset time of ms is allowed. Note: Sizes 0 : Timers can be added to the left- or right-hand side of the contactor body. On Size 00 they can be mounted to the front of the contactor. Size 0, and : Timers cannot be used on the same side as power pole adders. Size Devices: The operating coil must be changed. See page - and refer to the size operating coil listing. Order the coil listed for a - -pole device. Note: These coils can also be factory installed. Enclosed Devices: Please contact your local Rockwell utomation sales office or llen-bradley distributor. Contact Ratings: NEM 00 (0, 00V C max.) NEM P00 (, 00V DC max.) NEM Description Size On-Delay 00-FPT0 On-Delay 00-FPT0 00 Off-Delay 00-FPTB0 Off-Delay 00-FPTB0 Left-hand ON -TL Delay Left-hand OFF -TL Delay 0 Right-hand ON -TR Delay Right-hand OFF Cat No. -TR -TR Delay For open type, non-combination starters only. The normally open contacts can easily be changed to normally closed in the field. - Description NEM Size uxiliary Contact Contactors N.O. 0 - N.O. 0 - N.C. 0 -B N.C. 0 -BB N.O. and N.C. 0 -B N.C.L.B. 0 -BL N.O. -G0 N.O. -J N.O. auxiliary contacts for disconnect switch -G0 N.O. -K N.O. -K N.C. -GB0 N.C. -J N.C. -GB0 N.C. -K N.C. -K N.O. and N.C. -GB N.O. -K N.O. -K N.C.L.B. -GL0 Power Pole dders The N.O. and N.C. power poles may be field added to all size 0 Bulletin 00 line contactors and starters except the Bulletin 00L and 00FL. Two- and three-pole contactors will accept a maximum of two adder poles and four-pole devices will accept one adder pole. Each adder pole kit includes a mechanical load balancer to be used when only one power pole is added. Note: When power poles are added to Size,, or (- or -pole devices) the operating coil must be changed. Refer to the listing for the size of your contactor or starter. Order the operating coil listed for a - -pole device. Note: These coils can also be factory installed. NEM Description Size N.O. -P0 N.C. 0 -P0B N.C. Late Break -P0BL N.O. -P N.C. -PB N.C. Late Break -PBL N.O. -P -P0 ( N.O.) Size 0, mps. Wire Size NEM Size Lug Connectors ( per package) # WG Wire 0 # WG Wire R-N # /0 WG Wire R-N # /0 WG Wire R-N R-N of #/0 0 MCM Wire ll terminals of the 0 switches are furnished with self-lifting pressure plate connectors as standard. Description NEM Size Terminal Lug Kit Terminal Lug Kit Two #/ MCM required per terminal # WG 00 MCM required per terminal for Size and required per terminal for Size N.C. -PB N.O. -P N.C. -PB Contactor Kick-off Springs For horizontal mounting of - or -pole Bulletin 00 contactors and starters. Note: When kick-off springs are added to Size, or, the operating coil must be changed. Refer to the listing for the size of your contactor or starter. Order the operating coil listed for a -pole device. Note: These coils can also be factory installed. NEM Description Size 0 -N -N -N -N -LJ -LG

123 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Description NEM Size uxiliary Contact dder Decks The same - and -pole auxiliary contact blocks in various combinations of normally open and normally closed will slide and snap on to the front of the contactor. dder decks have convenient backed out wire clamps to make lugging of control wires unnecessary. Fits on Open Type devices only. N.O. 00-F0 N.O. - N.C. 00-F N.C. 00-F0 N.O F0 N.O.- N.C. 00-F N.O. - N.C. 00-F -pole N.C. 00-F0 V DC Interface Module Mounts to the top of the contactor. It provides a V DC, 0. w input signal that can be used to operate the 0V C coil of the contactor. Fits on Open Type devices only JE Latch ttachment On the front of the contactor. Fits on Open Type devices only. Interposing Contactor For open type Bulletin 00 and 00L FL 0V, 0 Hz 00-NX00D 0V, 0 Hz 00-NX00 Device Markers Snap easily into the coil cover of contactors and starters for component identification. maximum of five markers will fit on each contactor or starter. (Standard: 0 device markers per package) 0 -DM Bulletin 00 with device markers Top Wiring Kit Consists of () power lugs for the purpose of making extra connections to the load side of the contactor. second set of overload relays can be wired to these lugs if two motors are being controlled by a single contactor. 0 -TW0 -TW -TW -TW Cat No. -TW0 -TWP Voltage Suffix Code The cat. no. as listed is incomplete. Select a voltage suffix code from the table below to complete the Example: 0V, 0 Hz: 00-FL becomes 00-FLD. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Hz K Y KP D V T N G B 0 Hz J D T N B To complete cat. no., insert in the third position the desired numeric symbol (0 ) or one of the following letters, B, C, D, E, F, H, L, M, P, R, S, T, U, or W. 0 -

124 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Contactor ccessories Description Enclosure Type NEM Size dapter Plates For replacement of: llen-bradley (Bulletin 0 Series K) Cutler Hammer (Citation & Freedom Series) Furnas (Class and ESP 00) General Electric (Series 00) Joslyn-Clark (Type HP) Square D (Type S) Westinghouse (00 and W00 dvantage) (hinged), R, R//, /X (stainless) 0, -CP0 -CP For use on Bulletins V, V, V, V Contactors are supplied with one normally open and one normally closed auxiliary contact (00 rating) as standard. dditional auxiliary contacts, two normally open and two normally closed, can be added in the field. Overload ccessories Description uxiliary Contact 00V) uxiliary Contact (0 V DC) For use on Bulletins 00, 00F, 00FL, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V Description NEM Size uxiliary Contact For eutectic alloy overload relays only N.O. 00, -phase -00 N.C. 00, -phase -B00 N.O. -0 0, uxillary Contact N.C. -B0 For eutectic alloy overload relays only N.O. - Contact Ratings NEM 00 (0, 00V C max.) N.C. -B NEM P00 (, 00V DC max.) Description Max. Continuous Current Rating [] DIN Rail Mounting dapter for Bulletin compact type -pole overload relays 0 -MP C-N C-N DIN Rail Mounting dapter for Bulletin compact type -pole overload relays -MP 0 uxiliary contact for solid-state overload relays is included in the product. Non-combination starters only. uxiliary contact mounted on right-hand side of overload relay provides N.O. contact function. uxiliary contact mounted on left-hand side of overload relay provides N.C. contact function. To be mounted on right-hand side of overload to provide additional C contact function. -

125 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Voltage Control ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V Control Circuit Transformer with Top-Mounted Fuse Block Kits (Pre-Wired) NEM Size 0 Primary Voltage 0V Control Circuit Transformers with Top Mounted Fuse Blocks Capacity 0V Secondary Voltage Standard 00 W Extra 00 W Extra 00 W Extra 00 W Extra V V V V V -NPK -NPK -NPK -N0PK -NPK 0V & 0V 0 -NPK 0 -NPK 0 -NPK 0 -NPK 00 -NPK 00V -NPK -NPK -NPK -NPK -N0PK 0V -NPK -NPK -N0PK -NPK -NPK 0V & 0V 00 -NPK 0 -NPK 0 -NPK 00 -NPK 00 -NPK 00V -NPK -NPK -NPK -N0PK -N0PK 0V -NPK -N0PK -NPK 0V & 0V 0 -NPK 0 -NPK 00 -NPK 00V -NPK -NPK -N0PK 0V -N0PK -NPK 0V & 0V 0 -NPK 00 -NPK 00V -NPK -N0PK 0V -NPK 0V & 0V 00 -NPK 00V -N0PK Transformers for NEM sizes are included as standard. Type /X non-metallic enclosures and Type & hazardous location enclosures require transformers with separately mounted fuse blocks. For a complete listing of transformers, see page -. Capacity 0V Secondary Voltage Primary Voltage/ Standard NEM Size Pole Fuse Block V 0V -B-HXDX--N 0 0V & 0V 0 -B-BSX--N 00V -B-CXSX--N 0V -D-HXDX--N 0V & 0V 00 -D-BSX--N 00V -D-CXSX--N 0V -E-HXDX--N 0V & 0V 0 -E-BSX--N 00V -E-CXSX--N 0V -F-HXDX--N 0V & 0V 0 -F-BSX--N 00V -F-CXSX--N Transformers can be installed in Type, R, R// painted enclosures and Type /X stainless steel enclosures. Type /X non-metallic enclosures and Type & hazardous location enclosures require transformers with separately mounted fuse blocks. For a complete listing of transformers, see page

126 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Voltage Control ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V, Continued For Use When Fuse Block Is Not Integrated with the Transformers -R -Pole Fuse Block -R -Pole Fuse Block -R -Pole Fuse Block -R -Pole Fuse Block -R0 Fuse Cover with Fuse 0 These control circuit fusing kits are intended to be used for control circuit transformer protection and protection of control circuits capable of delivering no more than RMS symmetrical amperes, 00V maximum. (Fuses not included) Description One-pole kit panel-mounted (midget fuse) -R Control Circuit Fuse Block For Class CC rejection type fuses (fuses not included) -R Two-pole kit panel-mounted (two midget fuses) -R Three-pole kit panel-mounted (one midget fuse/two Class CC fuses) -R Three-pole kit panel-mounted (three Class CC fuses) -R Single-pole kit Bulletin 00 line controller mounted (Class CC fuses) -FR0 One-pole kit panel-mounted ( 0 Class J fuse) -R One-pole kit panel-mounted ( 00 Class J fuse) -R For control circuit transformers with a 0 V or larger rating, it is recommended that Bussmann Type FNQ-R, Ferraz-Shawmut Type TDR, Littelfuse Type KLDR time delay fuses, or equivalent be used for primary fusing. These kits use only Class CC or midget fuses (rated 0. 0 ) such as those offered by the following manufacturers: Bussmann KTK-R Ferraz-Shawmut TM R Littelfuse KLK -FR0 is rated for fuse maximum. Controller mounting applies to size 0 devices only. One cover per pole is required. Example: transformer with top-mounted fuse block requires three covers. Fuse block kit for separate control requires two covers. Fuses not included. Description NEM Size Single-pole kit Bulletin 00 line controller mounted (Class CC fuses) 0 -FR0 Note: One cover per pole is required. Example: transformer with top-mounted fuse block requires three covers. Fuse block kit for separate control requires two covers. -

127 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Disconnect Switch ccessories For use on Bulletins 0, 0L, 0, 0X,, H, M, V,,,,,,,, X, and V NEM Description Size Fuse Clips 0 0, 0V C, Class H 0 0-N 0 0, 0V C, Class J 0 0, 00V C, Class H 0 0, 00V C, Class J 0-N 0, 0V C, Class H 0, 0V C, Class J 0, 00V C, Class H 0-N 0, 00V C, Class J 00, 0V C, Class H 00, 0V C, Class J 00, 00V C, Class H 0-N 00, 00V C, Class J 0 00, 0V C, Class H 0 00, 0V C, Class J 0 00, 00V C, Class H 0-N 0 00, 00V C, Class J 0 00, 0V C, Class H 0 00, 0V C, Class J 0 00, 00V C, Class H 0-N 0 00, 00V C, Class J 0 0, 0V C, Class R 0-N0 0 0, 00V C, Class R 0 0, 0V C, Class R 0-N 0, 00V C, Class R 0-N 00, 0V C, Class R 00, 00V C, Class R 0-N 0 00, 0V C, Class R 0 00, 00V C, Class R 0-N 0 00, 0V C, Class R 0 00, 00V C, Class R 0-N 0 0, 0V C HRC Form II Fusing 0 0, 00V C HRC Form II Fusing 0, 0V C HRC Form II Fusing 0, 00V C HRC Form II Fusing 00, 0V C HRC Form II Fusing 00, 00V C HRC Form II Fusing 0 00, 0V C HRC Form II Fusing 0 00, 00V C HRC Form II Fusing 0 00, 0V C HRC Form II Fusing 0 00, 00V C HRC Form II Fusing uxiliary Contacts for Disconnect Switches N.O. 0 0-HRC00 0-HRC00 0-HRC00 0 -N N.C. 0 -N HRC Form II fusing for Canada only. For 0 0 only. Fuse clip not required. Fuse bolts directly to switch and trailer fuse block. 0 -

128 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Lug Connectors ( per package) Disconnect Size [] Description For Use With Wire Size 0 # WG Wire 0 # WG Wire C, F, R-N 00 # /0 WG Wire G, and V R-N 00 # /0 WG Wire Disconnect Switches R-N 00 () of #/0 0 MCM Wire R-N 00 # WG 00 MCM Wire (oversized) R-N 00 () of #/0 0 MCM Wire R-N0 R-N 00 () of #/0 0 MCM Wire Protective Fuse Covers -N or - R 00 fuse blocks R-N Switch Rating [] Fuse Class Fuse Clip Rating [] 0V 00V Non-fusible H, R H, R J N J Non-fusible Non-fusible H, R H, R 0 0 -N 00 J H, R N Non-fusible H, J, R Non-fusible H, J, R Non-fusible H, J, R Non-fusible H, J, R Non-fusible J ll terminals of the 0 switches are furnished with self-lifting pressure plate connectors (N, N, and N) as standard. Each kit contains three lugs. Each kits contains two lugs. Switch with right-hand mechanism. Switch with left-hand mechanism N -N -N -N -N 0 -

129 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Circuit Breaker ccessories For use on Bulletins 0, 0L, 0, 0X,, H, M, V,,,,,,,, X, and V Description NEM Size Circuit Breaker Kits, 0 / 00 and 0V, 0 0 and V 0 0-N0, and 0V,. 0 and V 0 0-N,. 00 and 0V,. 0 and V 0 0-N 0, 00V 0,. 0V 0-N 0, 0 0 and V 0, 0 00V 0, 0 0V 0, 0 0V 0-N 0, 0 0 V 00, 00 and 0V 00, 0 0 0V 0-N 00, 0 0 V 0, 0 00V 0, 0 0 0V 0, 0 0V 0-N 0, 00 V 0, V 0-N 0, V 0, 0 0V 0-N uxiliary Contacts for Disconnect Switches Contact Ratings NEM B00 and NEM P00. Not available on larger sizes. For Bolted and N.O. For Unilock N.C. For Enclosure Type. For Enclosure Types &. One normally open ( N.O.) dapter kit may be required. Bolted One normally open ( N.O.) Unilock One normally open ( N.O.) One normally closed ( N.C.) dapter kit may be required. Bolted One normally closed ( N.C.) Unilock One normally closed ( N.C.) 0 -N 0 -N Unilock One normally open ( N.O.) 0 -N Unilock One normally closed ( N.C.) 0 -N HMCP Circuit Breaker dapter Kits (for mounting or auxiliary contacts) 00 Frame -N 0 Frame -N 0 Frame - Enclosure Type, R//, R and /X (stainless steel) 0 Frame - Enclosure Type & (bolted & Unilock) and /X (non-metallic) 0 -N 0 Frame - Enclosure Type, R//, R, and /X (stainless steel) -N Unilock 0 Frame -N Unilock 0 Frame -N 0 -

130 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Pilot Device ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V Description Selector Switch Kits OFF-ON/HND-OFF-UTO HND-OFF-UTO OFF-ON FOR-OFF-REV TEST-OFF-UTO (spring return from TEST) Enclosure Type NEM Size (Lift-off) 00 -SS00 0 -SS0, R// -SS0HJ, X (stainless steel and non-metallic) -SS0HS, R// -SS0OJ, X (stainless steel and non-metallic) -SS0OS 0, R// -SS0RJ, X (stainless steel and non-metallic) -SS0RS, R// -SS0TJ, X (stainless steel and non-metallic) -SS0TS OFF-ON/ HND-OFF-UTO (Lift-off) -SS FOR-OFF-REV (Unilock) -N OFF-ON (Unilock) 0 -N HND-OFF-UTO (Unilock) -N R, & OFF-ON (Unilock) -N HND-OFF-UTO (Unilock) -N0 FOR-OFF-REV (Unilock) -N Push Button Kits STRT-STOP STRT-STOP FOR-REV-STOP HIGH-LOW-STOP STRT-STOP (Unilock) (Lift-off), R// 00 -PB00 0 -PB0 -PB -PB0SJ, X (stainless steel and non-metallic) -PB0SS, R// -PB0RJ 0, X (stainless steel and non-metallic) -PB0RS, R// -PB0WJ, X (stainless steel and non-metallic) -PB0WS & STRT-STOP (bolted) Bulletins 00, 0, 0, 0 with control transformer are supplied from the factory in Type (hinged) enclosures. For non-combination starters only. 0 -N -N Use 00H-DPHXX 0-0

131 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Pilot Device ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V, Continued Description Enclosure Type NEM Size Pilot Light Kits 0V, R// -PL0DJ 0V, X (stainless steel and non-metallic) -PL0DS 0V, R// -PL0J 0V, X (stainless steel and non-metallic) 0 -PL0S 0V, R// -PL0BJ 0V, X (stainless steel and non-metallic) -PL0BS 00V, R// -PL0CJ 00V, X (stainless steel and non-metallic) -PL0CS 00 -PL00 ON (Lift-off) 0 -PL0 -PL Optional Pilot Light Lens Covers Red 00T-NR Green 00T-NG mber ll 0 00T-N Blue 00T-NB Clear 00T-NC White 00T-NW ON (Unilock 0V) Red R, & -N0R 0 ON (Unilock 0V) Green (Unilock) -N0G Push-to-Test Pilot Light Kits 0V, R// -PT0DJ 0V, X (stainless steel and non-metallic) -PT0DS 0V, R// -PT0J 0V, X (stainless steel and non-metallic) 0 -PT0S 0V, R// -PT0BJ 0V, X (stainless steel and non-metallic) -PT0BS 00V, R// -PT0CJ 00V, X (stainless steel and non-metallic) -PT0CS Optional Push-to-Test Pilot Light Lens Covers 00T-N0 Red Green 00T-N mber ll 0 00T-N Blue 00T-N Clear 00T-N White 00T-N Voltage Suffix Code The as listed is incomplete. Select a voltage suffix code from the table below to complete the cat. no. Example: -PL0 becomes -PL0B. For other voltages, please consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Hz D B C For non-combination starters only. Bulletins 00, 0, 0, and 0 with control transformer are supplied from the factory in Type (hinged) enclosures. Pilot light kits and push-to-test pilot light kits include one green and one red cover as standard. n adapter ( -N) is required for each pilot light added to Size,, and Unilock enclosures. Supplied with red lens only. Note: Bulletins 0 and 0 with two pilot lights are supplied in hinged enclosures, with or without control circuit transformers. 0 -

132 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Pilot Device ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V, Continued Description Enclosure Type NEM Size ON (Unilock) -N0R Red Lens (0V) 0 ON (Unilock) -N0G Green Lens (0V) R, & Transformers for Pilot Lights (Unilock) 0V, 0 Hz and 0V, 0 Hz -NX 0V, 0 Hz and 0V, 0 Hz 00 -NX 00V, 0 Hz and 0V, 0 Hz -NX Replacement Bulbs for all Pilot Lights 0V coil voltage - incandescent 00T-N mber, green, red, or blue lens color 0V coil voltage - LED mber lens color 00T-N0 Green lens color 00T-N0G Red lens color 00T-N0R Blue lens color 00T-N0B 0/0/00V Coil Voltage - Incandescent mber, green, red, or blue lens color 00T-N 0/0/00V coil voltage - LED mber lens color 00T-N Green lens color 00T-NG Red lens color 00T-NR Blue lens color 00T-NB dditional Pilot Devices dditional pilot devices, R// 0 dditional pilot devices /X, X 0 dditional pilot devices (bolted) R, & 0 When the control voltage is other than 0V, 0 Hz or 0V, 0 Hz it is necessary to also use one of the following transformers. n adaptor ( -N) is required for each pilot light added to size,, and Unilock enclosures. Use Bulletin 00T devices (See page 0-) Use Bulletin 00H Type X devices (See page 0-) Use Bulletin 00H Type & devices (See page 0-) 0 -

133 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Enclosure ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V Description Enclosure Type NEM Size Metallic Conduit Connectors in. (. mm) 0 -N -/ in. (. mm) -N -/ in. (. mm) -N -/ in. (. mm), R//, R -N in. (. mm) -N Non-metallic Conduit Connectors / in. (. mm) 0-N / in. ( mm) 0 0-N in. (. mm) 0-N0 -/ in. (. mm), X (stainless steel and non-metallic) 0-N -/ in. (. mm) 0-N in. (0. mm) 0-N -/ in. (. mm) 0-N in. (. mm) 0-N Grounding dapters / in. (. mm), # 0 WG 0-N / in. ( mm), # WG 0 0-N0 in. (. mm), # WG 0-N -/ in. (. mm), # WG, X (stainless steel and non-metallic) 0-N -/ in. (. mm), # /0 WG 0-N in. (0. mm), # /0 WG 0-N -/ in. (. mm), # /0 WG 0-N in. (. mm), # /0 WG 0-N Handle Kits with Universal Link for Switch and Breaker 0 F-M Painted Metal -/ in. base, R, R// Painted Metal -/ in. base F-M Stainless Steel 0 F-S -/ in. base /X (stainless steel) Stainless Steel F-S -/ in. base Non-Metallic Handle -/ in. base, R, R//, /X (non-metallic) 0 F-P Hole Plugs 0. mm hole plug for pilot devices 00T-N. mm hole plug for resets and door safety hardware ll 0 -N 0 For combination starters only. Bulletin 0 grounding adapters are available for use with these conduit hubs. These bushings provide a convenient method of connecting a ground wire to the conduit system. See conduit connector (hub) above proper size. -

134 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued Enclosure ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, M, V,, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V, Continued Description Enclosure Type NEM Size Door Safety Hardware Kits Enclosure Size (H x W x D) x 0 x. in. 0 F-V 0 x 0 x. in. 0 F-V 0 x x. in. F-V R// x 0 x in. F-V Breather Bulletin 0, 0, 0, and Unilock and bolted Class I, Groups C and D Class II, Groups E, F and G Drain Bulletin 0, 0, 0, and Unilock and bolted Class I, Groups C and D Class II, Groups E, F and G Breather Drain Combination Bulletin 0, 0, 0, and Unilock and bolted Class I, Groups C and D Class II, Groups E, F and G 0-N 0 0-N 0-N 0 -GR -GR Ground Lug Kits -GR 0 Description of ccessory Kit Reset Buttons (Each Kit Contains One Reset) Type, R/ Bulletin 0 0 One Kit Required Per Starter Bulletin One Kit Required Per Starter Bulletin Two Kits Required Per Starter Pneumatic Timer Mounting Plate dapter (For Mtg. Bulletin Timer) Bulletin 0 and Unilock Size 0 Size Size Size Size -N -N -N -N 0-N Converts combination starter enclosure F to enclosure code D or J with door safety hardware. Standard on bolted Type R, &. The breather-drain combination can be in enclosure top as a breather or bottom as a drain. Specify () when both functions are required. Unilock suitable for Types & or Types R, & with the addition of a drain or a breather and drain. For Bulletins only. -

135 Bulletin 00 Line ccessories Field Installed NEM Non-Combination Contactors/Starters and Combination Contactors/Starters, Continued System ccessories For use on Bulletins 00, 00F, 00L, 00LP, 0, 0L, 0, 0L, 0, 0V, 0, 0X, 0, 0X, 0,, H, M, V,, H, M, V, 0, 0V,,, 0,,, 0,,, 0,,,,,,,,, X, V, X, and V Description Power Monitor Kit -phase, 0V C (Time Mark Model ) Enclosure Type NEM Size -PM -phase, 0V C (Time Mark Model B) (hinged), R, R//, /X (stainless) 0 -PM Terminal Block Panel Mount ( point) (hinged), R, R//, /X (stainless) 0 -HC For combination starters only. -phase power monitor kit includes the time mark phase monitor and socket. Up to two -point terminal blocks may be added to each combination starter. Timing Relays 0V C, ON-Delay -pin socket ( 00-HN) required 00-HTU s (hinged), R, R//, /X (stainless) 0 0V C, ON-Delay -pin socket ( 00-HN) required 00-HTBU0.0 0 s 0V C, OFF-Delay -pin socket ( 00-HN) required (hinged), R, R//, /X (stainless) 0 00-HTU s 0V C, OFF Delay -pin socket ( 00-HN) required (hinged), R, R//, /X (stainless) 0 00-HTBU0.0 0 s Control Relays DPDT -pole (hinged), R, R//, /X (stainless) 0 00-H Form C Single gni Contact PDT -pole Form C (hinged), R, R//, /X (stainless) 0 00-H Single gni Contact Relay Sockets -pin socket 0 00-HN (hinged), R, R//, /X (stainless) -pin socket 0 00-HN 0 -

136 0 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters Σπεχιφιχατιονσ Electrical Ratings NEM Size 00 0 P Load Voltage [V] Continuous Current Rating [] Service Limit Current Rating [] Maximum Hp Rating (Non-plugging and non-jogging duty) Maximum Hp Rating (Plugging and jogging duty) Transformer Primary Switching kva Rating (Inrush Current 0 times Continuous Current) Transformer Primary Switching kva Rating (Inrush Current = 0 to 0 times Continuous Current) Capacitor Switching kvr Maximum Circuit Closing Inrush Current [] Peak Including Offset Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø / -/ -/ -/ -/ -/ -/ -/ / / / -/ -/ Service-Limit Current Ratings The service-limit current ratings shown represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. t service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or the trip current of other motor protective devices used shall not exceed the service-limit current rating of the controller. Plugging or Jogging Service The listed horsepower ratings are recommended for those applications requiring repeated interruption of stalled motor current encountered in rapid motor reversal in excess of five openings or closings per minute and shall not be more than ten in a ten minute period. If maximum available current (at capacitor terminals) is greater than 000, please contact your local Rockwell utomation sales office, llen-bradley distributor, or NEM ICS- Standard. -/ -/ -/ -/ -/ -/

137 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters, Continued Mechanical Ratings NEM Size Mechanical Life (Millions of Operations) Maximum Number of uxiliary Contacts Pick-up (verage) Operating Time [ms] Drop-out (verage) P Construction NEM Size Power Contacts Contact Material uxiliary Contacts Type of Power Terminal Wire Size for Power Terminals Required Torque on Power Terminal Wire Clamps and Pressure Connectors or Lugs 0 # 0 WG 0 lb in Saddle or wire clamps # WG 0 lb in P # WG 0 lb in # WG lb in Pressure terminals # /0 WG 0 lb in # /0 WG lb in Silver alloy Silver # WG 00 MCM lb in Lugs sold separately. See page -. Direct bus connections only. 00 Pressure terminals # 0 WG lb in Environmental Requirements for Sizing of Wire ll wire rated F ( C) or higher must be sized per the local Electrical Code for F ( C) wire. NEM Size Operating Temperature Range ltitude Corrosion-Resistance Operating Position 0 P Starters with eutectic alloy Overload relay + F ( + C) Vertical Starters with SMP ll metal parts are treated for feet before derating Overload relay corrosion-resistance + F ( + C) Horizontal (provided condensation Vertical is prevented) 00 Horizontal 0 -

138 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters, Continued Short Circuit Rating Combination contactors and starters with disconnect switch: Bulletin 0, 0,, E, F, G, and X NEM Size Combination Contactors and Starters with Disconnect Switch: Bulletin 0, 0,, E, F, G, and X Fuse Type vailable Short Circuit mperes RMS Symmetrical [] 0 H, K 000 H, K J, R L 000 L 000 Lighting Contactor Rating [] Combination Lighting Contactors with Disconnect Switch: Bulletin 0L Fuse Type vailable Short Circuit mperes RMS Symmetrical [] 0 00 H, K H, K J, R Enclosure Type Combination Contactors and Starters with Circuit Breaker: Bulletin 0, 0,, E, F, G, and X NEM Size vailable Short Circuit mperes RMS Symmetrical [], R, R//, /X (stainless) /X (non-metallic) Unilock R,, & Bolted R,, & 0 000, R, R//, /X (stainless) /X (non-metallic) /X (non-metallic) Unilock R,, & Unilock R,, & Bolted R,, & R, R// Enclosure Type Combination Lighting Contactors with Circuit Breaker: Bulletin 0L Lighting Contactor Rating [] vailable Short Circuit mperes RMS Symmetrical [], R, R//, /X (stainless) /X (non-metallic) Unilock R,, & Bolted R,, & , R, R//, /X (stainless) /X (non-metallic) /X (non-metallic) Unilock R,, & Unilock R,, & Bolted R,, & Maximum Voltage [V] 00 Maximum Voltage [V] 00 Maximum Voltage [V] 0 00 Maximum Voltage [V]

139 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters, Continued C Coil Data NEM Size Operating Volt mperes Burden [V] Inrush 0 Hz Coils Sealed Heat Dissipation [W] & P. ( poles) 0. ( poles). ( poles) 0 0 ( poles) 0 0 ( poles). ( poles) 0. (Series L) (Interposing relay).. Economized DC Coil (Interposing relay).0. Economized DC Coil (Interposing relay).0. Economized DC Coil (Interposing relay).0 Coil Operating Limits 0% This rating is for the size contactor coil only. ll starters are shipped with an interposing relay as standard. Size starters are shipped with a 0 V control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. Size starters are shipped with a 0 V control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. Size starters are shipped with a 0 V control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. uxiliary Contacts (NEM 00 and P00) Bulletin, C Rating Designation 00 Maximum C Contact Rating Per Pole [] Continuous [V] Maximum Voltage Carrying Current 0 or 0 Hz Make Break [] Make Break Maximum DC Contact Rating Per Pole for, uxiliary Contacts (Maximum Continuous Carrying Current is ) DC Rating Designation V DC 0V DC 00V DC P (Requires Contacts in Series) 0. (Requires Contacts in Series) 0 -

140 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters, Continued Load-Life Curves Bulletin 00 Line contactors and starters are designed to provide superior performance in a variety of applications. These load-life curves are based on Rockwell utomation tests according to the requirements defined in IEC -. ctual contact life may vary based on the application, duty cycle, and environmental conditions from that indicated by the curves. To find the contactor s estimated electrical life, follow these guidelines: Contact Life for Mixed Utilization Categories C and C In many applications, the utilization category cannot be defined as either purely C or C. In those applications, the electrical life of the contactor can be estimated from the following equation: Choose the appropriate graph that most closely approximates the utilization category of the application. Locate the intersection of the life-load curve of the appropriate contactor with the application s operational current (Ι e ) found on the horizontal axis. Read the estimated contact life in millions of operations along the vertical axis. Utilization Categories Category C C Typical Duty Starting of squirrel cage motors and switching off only after the motor is up to speed. Starting of squirrel cage motors with inching and plugging duty. Bulletin 00 Load/ Life Curves C and C 0-0

141 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters, Continued Group Motor Ratings for NEM Contactors/Starters Manual Starters FL Range (mps) Group Rating (0V) Contactors w/o Limiter with Limiter Size 00 Size 0 Size Size Size 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN-00.. k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-TO 00-O 00-BO 0-MN k k 00-O 00-BO 00-CO 0-MN k k 00-O 00-BO 00-CO 0-MN k 0 k 00-BO 00-CO 0-MN+0-P0.0.0 k 00-CO 00-DO 0-MN+0-P k 00-CO 00-DO Group Rating (0V) Starters FL Range Manual Starters (mps) w/o Limiter with Limiter Size 00 Size 0 Size Size Size 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN-00.. k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-TO 0-O 0-BO 0-MN k k 0-O 0-BO 0-CO 0-MN k k 0-O 0-BO 0-CO 0-MN k 0 k 0-BO 0-CO 0-MN+0-P0.0.0 k 0-CO 0-DO 0-MN+0-P k 0-CO 0-DO is incomplete. Refer to page -. is incomplete. Refer to page

142 0 Bulletin 00 Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters, Continued Full Load Currents of -Phase, 0 Hertz C Induction Motors The full load currents listed below are average values for horsepower rated motors of several manufacturers at the more common rated voltages and speeds. These average values, along with the similar values listed in the U. S. National Electrical Code (NEC), should be used only as a guide for selecting suitable components for the Motor Branch Circuit. The rated full load current, shown on the motor nameplate, may vary considerably from the listed value depending on the specific motor design. TTENTION: The motor nameplate full load current should always be used in determining the rating of the devices used for Motor Running Overcurrent Protection. HP / / / / -/ -/ RPM Full Load Current [] 0V 0V 0V 00V 00V 000V Synchronous speed nameplate is usually less due to slip HP RPM Full Load Current [] 0V 0V 0V 00V 00V 000V

143 Bulletin 00 Line pproximate Dimensions NEM C Contactors Αππροξιματε Διμενσιονσ pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 00, 00F, 00FL, 00L and 00LP Contactors Note: Top mounting hole on Size 00 is / in. (. mm) to the left of centerline on Open Type. Mounting screws: #0 for sizes 0, / #0, or / # for sizes. NEM Size 00 /0 0 / Bulletin 00 00F-00FL Number of Switching Poles Bulletin 00L-00LP -- Width -/ () -/ (0.) -/ () -/ () -/ (00) -/ () -/ (0) -/ (.) -/ (0.) -/ (.) () -/ (0.) 0-/ (.) () For Feed-Through Wiring this dimension is -/ in. ( mm). For Feed-Through Wiring this dimension is -/ in. ( mm). For Feed-Through Wiring this dimension is -/ in. (0 mm). B Height -/ () () -/ () 0-/ () -/ (0) -/ (0) Dimensions in Inches (Millimeters) C Depth D E -/ (0.) -/ () -/ (0) -/ (.) -/ (.) -/ () -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ () -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) pproximate Shipping Weight in lbs (kg) (0.) (.) -/ (.) -/ (.) (.) -/ (.) -/ (.). (.) (.) () (0). (.). () (0.) 0 -

144 Bulletin 00 Line pproximate Dimensions NEM Reversing Starters Product Selection page - pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0 Full Voltage Reversing Starters with Eutectic lloy Overload Relay 0 NEM Size 00 0 Style With Eutectic lloy Overload Protection Without Overload Protection Width -/ () (0) -/ (0) -/ () -/ () -/ () -/ (.) -/ (00) -/ () B Height -/ () -/ () 0-/ () -/ () -/ () -/ () -/ () -/ (.) -/ () Dimensions in Inches (Millimeters) C Relay G Reset Depth D E F Depth -/ -/ -/ () () () -/ () -/ () -/ () -/ () -/ () 0-/ (.) -/ (.) -/ (.) -/ (0) -/ (0) -/ (0) -/ (00) -/ (0) -/ (0) -/ (00) -/ (00) -/ (0) -/ (0) -/ (00) -/ (0) -/ (0) -/ () -/ () -/ () -/ (0) -/ () -/ (0) pprox. Shipping Weight in lbs (kg) (.) 0 (.) -/ (.) (.) () (.) For dimensions, please contact your local Rockwell utomation sales office or llen-bradley distributor. 00 -/ -/ -/ -/ -/ -/ () (0) (.) (.) () (.) 0 (0) -/ (0) -/ () -/ () -/ () -/ (.) -/ (00) -/ () -/ () -/ () 0-/ () -/ () -/ () -/ () -/ (.) -/ () -/ (0) -/ (00) -/ (0) -/ (00) -/ (00) -/ (0) -/ (00) -/ (00) -/ (0) -/ (0) -/ (00) -/ (0) -/ (0) -/ () -/ () -/ () -/ (0) -/ () -/ (0) -/ (.) -/ (00) For dimensions, please contact your local Rockwell utomation sales office or llen-bradley distributor. Sizes 00 only. Sizes only. -/ () () 0 (.) (.) (.) -

145 Bulletin 00 Line pproximate Dimensions NEM Reversing Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0V Full Voltage Reversing Starters with Solid State Overload Relay NEM Size Overload Relay 0 Solid-State Solid-State Solid-State Solid-State Solid-State Width -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ () -/ () llow additional space for internal wiring. B Height -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ (00) -/ (00) -/ (0) -/ (0) -/ (0) -/ (0) -/ () -/ () -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ () -/ () -/ (0) -/ (0) F Relay Reset Depth () -/ () () -/ () -/ () -/ () -/ (0) -/ () -/ () -/ () G / (.) / (.) / (.) / (.) -/ () -/ () () -/ () () () pprox. Shipping Weight in lbs (kg) Size 0:. (.) Size :. (.). (.). (.0).0 (.0) (0.) 0 -

146 Bulletin 00 Line pproximate Dimensions NEM Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0 Full Voltage Starters with Eutectic lloy and Solid-State Overload Relay Size 00 with Eutectic lloy Overload Relay Size 0 with Eutectic lloy 0 NEM Size Width B Height Size 00 with Solid-State Overload Relay Dimensions in Inches (Millimeters) C Relay Reset Depth D E pprox. Shipping Weight in lbs (kg) (0.) 0 -/ (0.) -/ () -/ () -/ (0) -/ (0) -/ (.) -/ (00) -/ () -/ () -/ (0) -/ (0) -/ (.) -/ () -/ () -/ () -/ (0) -/ (0) (.) () -/ () -/ () -/ (0) -/ (0) -/ (0.) -/ () -/ () -/ () -/ (0) -/ (0) (.) -/ () -/ () -/ () -/ (0) -/ (00) 0 () -/ () 0-/ () -/ () -/ () () () -/ () -/ (00) -/ () -/ () 0 (0) 0 () () -/ () () -

147 Bulletin 00 Line pproximate Dimensions NEM Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0 Full Voltage Starters with Solid-State Overload Relay NEM Size 0 Overload Relay Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Width -/ () -/ () -/ (00) -/ (00) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () B Height -/ () -/ () -/ () 0-/ () -/ () -/ (0) -/ () -/ () -/ () -/ () -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E -/ () -/ () -/ () -/ (0) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ () -/ () 0-/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (00) -/ (00) F Relay Reset Depth -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ () -/ () pprox. Shipping Weight in lbs (kg). (.).0 (.).0 (.). (.). (.) (.) 0 Note: For Bulletin 0 Size 00, please contact your local Rockwell utomation sales office or llen-bradley distributor. -

148 Bulletin 00 Line pproximate Dimensions NEM Multi-Speed Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0E, 0F, and 0G Multi-Speed Starters with Eutectic lloy Overload Relay NEM Size 0 0 Width (0) -/ (0) -/ () -/ () -/ () -/ (.) 0-/ (0.) -/ () -/ () -/ () B Height -/ () 0-/ () -/ () -/ () -/ () -/ () 0-/ () -/ (.) -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E -Speed Separate Winding Bulletin 0E -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ (0) -/ (00) -/ (0) -/ (0) -/ (00) -/ (00) -/ (0) -/ (00) -Speed Consequent Pole Bulletin 0F and 0G -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ (0) -/ (00) -/ (0) -/ (0) -/ (00) -/ (0) -/ (00) -/ (00) F Relay Reset Depth -/ () -/ () -/ () -/ () -/ () -/ () G -/ () -/ () -/ () -/ (0) -/ () -/ () -/ () -/ () -/ (0) -/ () pprox. Shipping Weight in lbs (kg) -/ (.) -/ (.) (.) (.) (.) (.) -/ () (.) (.) (.) 0 -

149 Bulletin 00 Line pproximate Dimensions NEM Multi-Speed Starters Product Selection page - pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type Enclosure for Bulletin 0E, 0F, and 0G Multi-Speed Starters with Solid State Overload Relay NEM Size Overload Relay 0 Solid-State Solid-State Solid-State Solid-State Solid-State Solid-State 0 Solid-State Solid-State Solid-State Solid-State Solid-State Dimensions in Inches (Millimeters) Width B Height C Depth D E (0) (0) -/ (0) -/ (0) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () 0-/ (0) 0-/ (0) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () 0-/ () -/ (0) -/ () -/ (0) -/ () -/ () -/ () -/ () -/ () -/ () -Speed Separate Winding Bulletin 0E -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ () -/ () -/ (0) -/ (0) -/ (0) 0-/ () -/ (0) -/ () -/ (0) -/ (0) -/ (00) -/ (00) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (00) -/ (00) -/ (00) -/ (00) -/ (0) -/ (0) -/ (00) -/ (00) -/ () -/ () -Speed Consequent Pole Bulletin 0F and 0G -/ () -/ () 0-/ () (0) -/ () -/ () -/ () -/ (0) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ () -/ () -/ (0) 0-/ () -/ (0) -/ () -/ (0) -/ (0) -/ (00) -/ (00) -/ (0) -/ (0) -/ (0) -/ (0) -/ (00) -/ (00) -/ (0) -/ (0) -/ (00) -/ (00) -/ (00) -/ (00) F Relay Reset Depth -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (.) -/ () -/ () 0-/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ () -/ () G -/ () -/ () -/ (0) -/ (0) pprox. Shipping Weight in lbs (kg). (.). (.). (.).0 (.). (.) () -/ () -/ () -/ () -/ ().0 (.). (.).0 (0.).0 (.) (.) 0 -

150 Bulletin 00 Line pproximate Dimensions NEM Multi-Speed Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0VE, 0VF, and 0VG Multi-Speed Starters with Eutectic lloy Overload Relay 0 NEM Size 0 0 Width -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) 0-/ (.) -/ (0.) B Height -/ (.) 0-/ (.) 0-/ (.) -/ (.) -/ (0.) -/ (.) 0-/ (.) 0-/ (.) -/ (.) -/ (0.) C Depth -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) D Dimensions in Inches (Millimeters) E Relay Reset Depth F G H J K -Speed Separate Winding Bulletin 0VE -/ (00) -/ (00) -/ (00.) -/ (00.) -/ (0.) () -/ (0.) -/ (0.) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) / (.) -Speed Consequent Pole Bulletin 0VF/0VG -/ (00) -/ (00) -/ (00.) -/ (00.) -/ (0.) () -/ (0.) -/ (0.) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) / (0.) -/ () -/ (.) -/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (.) -/ (0) -/ (.) -/ (0) -/ (0.) -/ (0.) -/ (0.) -/ (.) -/ (0) / (.) / (.) -/ (.) -/ (.) (.) / (.) / (.) -/ () -/ (.) (0.) pprox. Shipping Weight in lbs (kg). (). (). (0) 0-/ (.) (.) (.) -/ (0.) -/ (.) llow additional space for internal wiring. -0

151 Bulletin 00 Line pproximate Dimensions NEM Multi-Speed Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0VE, 0VF, and 0VG Multi-Speed Starters with Solid State Overload Relay Note: The typical drawing above shows -point mounting. Sizes have -point mounting holes at each corner of the mounting plate. NEM Size Overload Relay 0 Solid State Solid State Solid State Solid State Solid State Width -/ () -/ () -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ () -/ () llow additional space for internal wiring. -Speed Separate Winding Bulletin 0VE B Height -/ () -/ () 0-/ () -/ (0) -/ () -/ (0) () -/ () -/ (0) -/ (0) Dimensions in Inches (Millimeters) C Depth D E -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (00) -/ (00) -/ (00) -/ (00) -/ (00) -/ () -/ (00) -/ () -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) F Relay Reset Depth () -/ () -/ (.) -/ () -/ (.) -/ () -/ (0) -/ () -/ () -/ () G / (.) / (.) / (.) / (.) -/ () -/ () -/ () -/ () () () pprox. Shipping Weight in lbs (kg). (.).0 (.). (.).0 (.) (.) 0 -

152 Bulletin 00 Line pproximate Dimensions NEM Multi-Speed Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0VE, 0VF, and 0VG Multi-Speed Starters with Solid State Overload Relay, Continued 0 NEM Size Overload Relay 0 Solid-State Solid-State Solid-State Solid-State Solid-State Width -/ () () -/ () -/ () -/ () 0-/ () -/ () -/ () -/ (0) -/ (0) llow additional space for internal wiring. -Speed Consequent Pole Bulletin 0VF and 0VG B Height -/ (.) -/ () 0-/ () -/ (0) -/ () -/ (0) () -/ () -/ (0) -/ (0) Dimensions in Inches (Millimeters) C Depth D E -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ (00) -/ (00) -/ (00) -/ () -/ (00) -/ () -/ (0) -/ (0) -/ (0) -/ (0) -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ (0) -/ (0) F Relay Reset Depth () -/ () -/ (0) -/ () -/ () -/ () -/ (0) -/ () -/ () -/ () G / () / () / ) / ) -/ () -/ () -/ () -/ () (0) (0) pprox. Shipping Weight in lbs (kg). (.).0 (.). (.).0 (.) (.) -

153 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type General Purpose Enclosure for Bulletins 00 & 00L Contactors - -Pole NEM Size 00 /0 0 /0, Pole Pole - -Pole Pole - -Pole Pole Width -/ () -/ () -/ () 0-/ (0.) -/ (.) -/ (.) B Height -/ () 0-/ (0.) -/ (.) 0-/ () -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E F -/ (0) -/ (.) -/ (.) -/ (00) -/ (0.) -/ () -/ () -/ (0) 0-/ () (0.) -/ (.) -/ () -/ () -/ (0.) -/ (.) -/ (.) (0) () / (.) / (.) / (.) / (.) / (.) / (.) pprox. Shipping Weight in lbs (kg) (.) -/ (.) -/ (.) () 0 () Type General Purpose Enclosure for Bulletins 00 & 00L Contactors - -Pole 0 NEM Size - -Pole 00 Pole - -Pole 00 Pole Pole 00 Pole Width -/ (0) -/ (.) -/ (.) B Height 0-/ () -/ (.) -/ (0.) Dimensions in Inches (Millimeters) C Depth D E F -/ (0) -/ (.) 0-/ (.) -/ () -/ () (0.) -/ (0) () -/ (.) / (.) pprox. Shipping Weight in lbs (kg) Note: For Types R/, /X, X, and Bolted Type & and R, & dimensions, please contact your local Rockwell utomation sales office or llen-bradley distributor. / (.) / (.) () () -

154 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type General Purpose Enclosures for Bulletins 0, 0E, 0F, and 0G Starters NEM Size Bulletin No. pproximate Dimensions in Inches (Millimeters) Width B Height C Depth D E F pprox. Shipping Weight in lbs (kg) / () 0 () () -/ () -/ (.) -/ (.) 0 0-0E 0-/ () -/ () -/ () -/ () -/ () / (.) (.) 0-0E 0F-0G -/ () -/ () -/ () -/ () -/ () / (.) (.) 0-0E -/ () -/ (0) -/ () -/ (00) -/ () / (.) -/ (.) 0-0E 0F-0G -/ () -/ () -/ () -/ () -/ (0) / (.) -/ (.) 0-0E -/ () 0-/ () -/ (0) -/ () () / (.).() 0F-0G -/ () -/ () -/ (0) -/ () (0) / (.) 0-0E -/ () -/ () -/ () (0) -/ () / (.) 0 () 0F-0G -/ () -/ () -/ (0) (0) -/ () / (.) 0-0E 0F-0G -/ () -/ (0) 0-/ (.) () -/ () / (.) Please contact your local Rockwell utomation sales office or llen-bradley distributor. Type General Purpose Enclosures for Bulletin 0 Full Voltage Starters 0 NEM Size pproximate Dimensions in Inches (Millimeters) Width B Height C Depth D E F pprox. Shipping Weight in lbs (kg) 00 Ø -/ (0) -/ () -/ () -/ () -/ (.) -/ (.) 00 Ø -/ () -/ () -/ () -/ () -/ (.).() 0 -/ () 0-/ (0) -/ () -/ (0) -/ (0.) / (.) -/ (.) -/ () -/ () -/ () 0-/ () -/ (.) / (.) 0-/ (.) 0-/ (0) 0-/ () -/ (0) (0) -/ (.) / (.) () -/ (0) -/ () -/ () -/ () (0) / (.) (.) -/ (0) (0) 0-/ () () () / (.) Wall -/ () -/ () () -/ () 0-/ () Floor - Please contact your local Rockwell utomation sales office or llen-bradley distributor. With reset only. With push button, selector switch, or pilot light. Note: For Type with control transformer dimensions, please contact your local Rockwell utomation sales office or llen-bradley distributor. -

155 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type R/ Enclosure without Control Transformer for Bulletin 0 NEM Size 0 Width -/ (0) -/ (.) -/ (.) -/ (.) B Height -/ (0) -/ (.) -/ (.) -/ (.) pproximate Dimensions In Inches (Millimeters) C Depth D E F G H J K (.) -/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) 0-/ (.) (.) -/ (.) () -/ (0.) -/ (.) / (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) Type R/ Enclosure without Control Transformer for Bulletin 0 NEM Size 0 Width -/ (.) -/ (.) -/ (0) -/ (.) B Height -/ (0.) -/ (0.) -/ (.) -/ (.) pproximate Dimensions In Inches (Millimeters) C Depth D E F G H -/ (.) -/ (0.) -/ (0.) (.) -/ (.) -/ (.) -/ (.) (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) 0-/ (.) -/ (.) 0-/ (.) -/ (.) Note: For Type R/ with control transformer dimensions, please contact your local Rockwell utomation sales office or llen-bradley distributor. / (.) / (.) / (.) / (.) pprox. Shipping Weight in lbs (kg) -/ (.) -/ (.) -/ (.) -/ () 0 -

156 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type /X Enclosure without Control Transformer for Bulletin 0 NEM Size 0 Width -/ (0) -/ (.) -/ (.) -/ (.) B Height -/ (.) -/ (.) -/ (.) 0-/ (.) pproximate Dimensions In Inches (Millimeters) C Depth D E F G H J K L M -/ (.) -/ (.) -/ (0.) -/ () -/ (.) -/ (.) 0-/ (.) (.) -/ (.) () -/ (0.) -/ (.) / (.) / (.) / (.) / (.) (0.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) -/ (.)V -/ (.) -/ (.) -/ (.) -/ () / (.) (.) / (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ () Type /X Enclosure without Control Transformer for Bulletin 0 0 NEM Size 0 Width -/ (.) -/ (.) -/ (0) -/ (.) B Height 0-/ (.) -/ (.) 0-/ (.) -/ (.) pproximate Dimensions In Inches (Millimeters) C Depth D E F G H J K L M N -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) -/ (0.) -/ (0.) -/ (.) -/ (0) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) 0-/ (.) Note: For Type /X with control transformer and Type X dimensions, please contact your local Rockwell utomation sales office or llen-bradley distributor. -/ (.) -/ (.) -/ (.) -/ () / (.) (.) / (.) -/ (.) pprox. Shipping Weight in lbs (kg) (.) (0). (.) 0 (.) -

157 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type (Enclosure Code "") General Purpose Painted Enclosure for Bulletins 0, 0L, 0, 0L, 0, 0X, 0, 0X,, M, V,, M, V, E, F, G, E, F, G, 0,,, 0,,, 0, and NEM Size Bulletin No X, 0X , 0L, 0, 0L,, 0, 0, M, M, E, F, G, E, F, G 0, 0L, 0, 0L,, 0, 0L, PW, PW 0,, YD 0,, 0, 0, E, F, G, E, F, G 0, 0, E, F, G, E, F, G 0, 0L, PW 0,, YD, YD 0,, 0,, 0, 0L, 0, 0L, 0, 0X, 0, 0X,,, E, F, G PW 0,, PW, YD 0,,, 0,, YD 0,,, 0,, E, F, G PW 0 Height.0 () 0 () 0 (0) () 0 () B Width 0.0 () 0. () () 0. (). () Size Size pproximate Dimensions in Inches (Millimeters) C Depth. (0). (). (). (0).00 (0) D Mounting. (). (0). (0). (). () E Mounting. (). () 0 (0) F Mounting. (). (). (). () G Handle Depth Sizes 0,, and have one top mounting hole located on the center line. Larger size enclosures have two top mounting holes located as shown.. (). (). (). (). (). (). () pprox. Shipping Weight in lbs (kg) 0 (.) 0 (0.) 0 (.) 0 (.) 0 (0.) - 0

158 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type R// (Enclosure Codes "D", "F", and "J") Rainproof, Dusttight Industrial Use Enclosures for Bulletins 0, 0L, 0, 0L, 0, 0X, 0, 0X,, M, V,, M, V, E, F, G, E, F, G, 0,,, 0,,, 0, and 0 NEM Size Bulletin No. 0X, 0X 0, 0 0, 0L,, , 0, M, M, E, F, G, E, F, G 0, 0 0, 0L,, PW, PW 0,, YD 0,, 0, 0, E, F, G, E, F, G 0, 0L, 0,, E, F, G, E, F, G PW 0,, YD, YD 0,, 0,, PW 0,, PW, YD 0,,, 0,, 0, 0L, 0, 0L, 0,, E, F, G, E, F, G PW 0 YD 0,,, 0,,, Height.0 () 0 () 0 (0) () 0 () () B Width 0.0 () 0. () () 0. (). (). (00) C Depth. (0) 0. (). (). (0) (0) () pproximate Dimensions in Inches (Millimeters) D Mounting. (). (.0). (0). (). () E Mounting. (). () 0 (0). () F Mounting. (). (). (). (). () G Handle Depth H J. (). (). (). (). (). (). (). (). (0). (0). () 0. () 0. () 0. () (.). () pprox. Shipping Weight in lbs (kg) 0 (.) 0 (0.) 0 (.) 0 (.) 0 (0.) 0 (.) Sizes 0,, and have one top mounting hole located on the center line. ll sizes in large enclosures have two top mounting holes located as shown. Fusible disconnect switch with Class J fuses. Fusible disconnect switch with Class R fuses. -

159 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type R (Enclosure Code "N") Rainproof. Enclosures with Extra Panel Space Bulletins X, X,,,,,, NEM Size Bulletin No. Width... X X 0. () X, X PW, PW, YD, YD, (), X PW, PW PW PW YD, YD 0. YD YD (), X, X X PW YD 0. (), X X. () X, X. (00) Fusible disconnect switch with Class J fuses. Fusible disconnect switch with Class R fuses. B Height 0 () 0 (0) () () 0 () () C Depth. ().0 (). (0). (0) (0) () pproximate Dimensions in Inches (Millimeters) D Mounting. (). (). (). (.). (.) E Mounting 0 (). () () () () () F Mounting 0 (). () 0. (0). (0) 0. (0). (0) G Handle Depth H J. (). (). (). (). (). (). (). () pprox. Shipping Weight in lbs (kg) 0 (0.) 0 (.). (). (). () 0 (.) 0 (0.) 0 (.) 0 -

160 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type /X (Enclosure Codes "C") Stainless Steel Industrial Use Enclosures for Bulletins 0, 0L, 0, 0L, 0, 0,, M,, M, E, F, G, E, F, and G 0 NEM Size Bulletin No. 0, 0L 0, 0L, 0, 0, M, M, E, F, G, E, F, G, 0, 0L, 0, 0L,, 0, 0L, Height.0 () 0 () 0, 0, E, F, G, E, F, G 0 0, 0L (0) 0, 0,, F, G, E F, G 0, 0L 0,, E, F, G 0, 0L 0 () B Width 0.0 () 0. () () 0. () C Depth. (0). (). (). () pproximate Dimensions in Inches (Millimeters) D Mounting. (). (). (0). () E Mounting () F Mounting () () G Handle Depth H J Sizes 0,, and have one top mounting hole located on the center line. ll sizes in large enclosures have two top mounting holes located as shown. Fusible disconnect switch with Class J fuses.. (0) 0 (0). (0). (). (). (). (). (). (). (). (). (). () 0. () 0. () 0. () (.) pprox. Shipping Weight in lbs (kg) 0 (.) 0 (0.) 0 (.) 0 (.) -0

161 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type /X (Enclosure Codes "S") Non-metallic, Corrosion-resistant Enclosures for Bulletins 0, 0L, 0, 0L, 0, 0,,, E, F, G, E, F, and G NEM Size Bulletin No. 0..., , 0, E, F, G, E, F, G, Height (0) (0) 0, 0, E, F, G, E, F, G. () 0, 0,, E, F, G 0, 0,,, E, F, G, E, F, G. () pproximate Dimensions in Inches (Millimeters) B Width 0 () (). (). () C Depth. (). () () () D Handle Depth. (). (). (). (). () pprox. Shipping Weight in lbs (kg) (.) 0 (.) 0 (.) 0 () 0 -

162 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type R (Enclosure Code "N") Rainproof Enclosures with Extra Panel Space for Bulletins X and X Bulletin No. X, X Bulletin No. X, X NEM Size -/ () in. Hub / () / in. Hub / () / in. Hub pproximate Dimensions in Inches (Millimeters) N P R T Inside Outside Inside Outside Inside Outside Inside Outside -/ () -/ in. Hub -/ () / in. Hub -/ () / in. Hub / () / in. Hub -/ (0) -/ in. Hub -/ () / in. Hub -/ () in. Hub -/ () -/ in. Hub -/ () in. Hub -/ (0) -/ in. Hub -/ (0) -/ in. Hub -/ () in. Hub / () / in. Hub -/ () in. Hub -/ (0) -/ in. Hub -/ () / in. Hub -/ () -/ in. Hub -/ () in. Hub pproximate Dimensions in Inches (Millimeters) U V W NEM Size Inside Outside Inside Outside Inside Outside / () -/ () / () -/ () / in. Hub / in. Hub / in. Hub / in. Hub / () -/ () -/ (0) -/ () () () / in. Hub / in. Hub -/ in. Hub in. Hub -/ in. Hub -/ in. Hub / () / in. Hub -/ () / in. Hub () -/ in. Hub -/ () in. Hub () -/ in. Hub -/ () in. Hub 0 -

163 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Unilock Enclosures Type R, &, Class I (Enclosure Code "U") Groups C & D, Class II, Groups E, F & G Divisions & for Bulletins 0, 0, and 0 Note: For bolted enclosures Type & and R,, & dimensions, consult factory. -

164 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bolted Enclosures Type & and Type R, &, Class I, Groups C & D, Class II, Groups E, F, & G Divisions & for Bulletin 0 Full Voltage Reversing Starters NEM Sizes 0 NEM Sizes 0 NEM Size (.) -/ (.) pproximate dimensions in inches (millimeters) Wide B High C Deep D E F G -/ (.) -/ (.) 0-/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -

165 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bolted Enclosures Type & and Type R, &, Class I, Groups C & D, Class II, Groups E, F & G Divisions & for Bulletin 0 Full Voltage Starters NEM Sizes 0 NEM Sizes NEM Size 0- pproximate dimensions in inches (millimeters) Wide B High C Deep D E -/ (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (0.) -/ (0.) -/ (.) () -/ (.) NEM Size NEM Size pproximate dimensions in inches (millimeters) Wide B High C Deep D E F G -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) 0-/ (.) -/ (.) -/ (.) (0.) 0 () -/ (.) -/ (.) -/ (.) -/ (.) 0 -

166 Bulletin 00 Line pproximate Dimensions For NEM C Contactors pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bolted Enclosures Type & and Type R, &, Class I, Groups C & D, Class II, Groups E, F & G Divisions & for Bulletin Full Voltage Combination Starters NEM Sizes 0 NEM Sizes NEM Size pproximate dimensions in inches (millimeters) Wide B High C Deep D E F G H J (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) pprox. Ship Wt. in Lbs. (Kg) 00 (0) (.) 0 NEM Size -

167 Bulletin 00 Line NEM Renewal Parts Bulletin 00 Line of Contactors and Starters Used on Size 00, Series B Used on Size 00, Series D Used on Size 0 through Size 00 C Operating Coils Series Series B Series D - -Pole Size 0 Size /0 0 -Pole - -Pole -Pole - -Pole Size Size 0 - -Pole - -Pole Voltage [V] Frequency [Hz] Part. No. 0 G0 T0 0 G0 T0 CB0 CC0 CC0C G T CB CC CCC 0 0 CB CBC CC CCC T0 CB CC CCC 0 0 G0 0 0 G CB CBC CC CCC CB CBC CC CCC T 0 CB CC CCC 0 0 G 0 0 G00 T0 CB0 CC0 CC0C 0 0 G T0 CB CBC CC CCC 0 G T CB CBC CC CCC 0 0 G G T CB0 CB0C CC0 CC0C CB CC CCC 0 0 T 00 0 G T CB CBC CC CCC 00 0 CB CC CCC T 00 0 G -Pole - -Pole Size Size Pole - -Pole -Pole - -Pole Size Size 00 Size Size Pole - -Pole Series Series L Voltage [V] Frequency [Hz] Part No. 0 CD0 CD0C CD CDC CE CEC CF F 0 0 CD CDC CE CEC CF F CD CDC CE CEC CF F 0 0 CD CDC CE CEC CF F 0 CD CDC CE CEC CF F 0 0 CD CDC CE CEC CF F 0 CD0 CD0C CE0 CE0C CF0 F0 0 CD CDC CE CEC CF F 0 CD CDC CE CEC CF F 0 0 CD0 CD0C CE0 CE0C CF0 F CD CDC CE CEC CF F 00 0 CD CDC CE CEC CF F 00 0 CD CDC CE CEC CF F For non-motor loads (Bulletin 00L). For motor rated contactors and starters. lso for 0V, 0Hz. lso for 0V, 0Hz. 0 -

168 Bulletin 00 Line NEM Renewal Parts 0 Bulletin 00 Line of Contactors and Starters, Continued Single Pole Contact Kit Sizes 00 (Includes Front and Rear Stationary Contact, Movable Contact and Contact Spring) Motor Rated Contactors and Starters (Bulletin 00, 0, 0, and 0) Non-Motor Rated Contactors (Bulletin 00L) Size Part No. Size No. of Poles Part No. -Pole Z-0 00 (Series ) -Pole Z-0 -Pole Z / P (Series ) Z-0 Z- 00 (Series ) Z-0 Z-0 (Series L) (Series L) (Series B&C) (Series B&C) Manual Reset (Eutectic lloy) Overload Relays Heater Elements Order heater elements as a separate item. See pages - and - for heater element selection tables. Size 00 (Series ) Part No. -Phase Bulletin 0 use -BOV Bulletin 0X-0 use -BOV 00 (Series B & D) -JOV BOV -Phase 00 (Series ) -BOV 00 (Series B & D) -BOV P Note: uxiliary contacts on Size and overload relays are replaceable. Order -. See page - for complete information. There are no replacement contacts for Series B and Series D, Size 00 device. Noted part numbers are for a complete set of movable contacts and springs. Stationary contacts are available only as part of the Stationary Contact Block ssembly. Not for use on Power Pole dders. Replace complete Power Pole dder Kit with one selected from the listing on page -. Does not accommodate terminal mounted current transformers. ccommodates terminal mounted current transformers. Mounting plate is not included. Power Pole dder Kit (Used Only for - and -Pole Devices) Motor Rated Contactors and Starters Size 0 -P0 -P -P -P Non-Motor Rated Contactors Rating [] Part No. /

169 Solid-State Overload Relays Overload Relay Code Selection For pplication on Bulletin 00 Line Starters and NEM Pump Panels Starters Without Overload Relays for Field ssembly of Starters Using Bulletin Overload Relays These products are intended for field installation of Bulletin Eutectic, or solid-state overload relays. (Select Bulletin overload relays from page -0 page -.) They ship in a starter carton with provisions for mounting the overload relay (includes a starter mounting plate, screws/bolts and instructions). Eutectic lloy Overload Relays Overload relay codes do not apply. Use as listed in product selection tables. Select heater elements from page -. Starter Cat. Nos. marked in blue with eutectic alloy overload relays are part of the B Express Program. Starters with solid-state overload relays are not presently part of the B Express Program. ll Sizes No overload relay. Bulletins 0,, and require two overload relays. Bulletins 0,, and require two overload relays. When selecting the proper solid-state overload relay or heater, divide motor nameplate full load amperes by.00. Use this value to select the proper overload relays. Bulletins 0,, and have one overload relay. When selecting the proper solid-state overload relay or heater, divide motor nameplate full load amperes by.. Use this value to select the proper overload relays. E Plus Solid-State Overload Relay (Selectable Class 0, 0, or 0) (utomatic/manual Reset) For use with Bulletins 0, 0V, 0, 0, 0,, M,, 0,,, 0,,, 0,,, 0,,, X, X,,,,,, and. NEM Size Full Load Current djustment Range () Overload Relay Code Class C D.0.0 E. F 0..0 B 0..0 C 0,.0.0 D PW YD.0.0 E. F. G H. G PW H YD J J PW 0 K YD 0 L 0 0 K PW 0 0 L YD 0 0 M PW 0 00 N YD PW 0 00 R YD Bulletins 0,, and require two overload relay codes to complete the The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Bulletins 0,,,, and have two overload relays and require two overload relay codes to complete the When selecting the proper SMP overload relay, divide motor nameplate full load amperes by.00. Use this value to select the proper overload relay codes. Bulletins 0,,,, and have one overload relay. When selecting the proper SMP overload relay, divide motor nameplate full load amperes by.. Use this value to select the proper overload relay code. These solid-state overload relays have an interposing relay with a 0V C coil. Order by description. E Solid-State Overload Relay: Inputs/ Output For use with Bulletins 0, 0V, 0, 0, 0,, M,, 0,,, 0,,, 0,,, 0,,, X, X,,,,,, and. NEM Size 00 0 Full Load Current djustment Range () Overload Relay Code EC ECB EC ECB ECC ECD ECD 0 ECE 0 ECF 0 0 ECH 0 ECK E Plus Solid-State Overload Relay: Inputs/ Outputs, Built-In Ground Fault Sensor, PTC Thermistor Input For use with Bulletins 0, 0V, 0, 0, 0,, M,, 0,,, 0,,, 0,,, 0,,, X, X,,,,,, and. NEM Size 00 0 Full Load Current djustment Range () Overload Relay Code EC ECB EC ECB ECC ECD ECD 0 ECE 0 ECF 0 0 ECH Bulletin 0 requires two overload relay codes to complete the cat. no. The first code will denote the high speed overload relay and the second code will denote the low speed overload relay. Rockwell utomation recommends using 0 or 0V C coils on all NEM Starters with E solid-state overload relays. When using coil voltages other than 0 or 0V C, consult your local Rockwell utomation distributor. 0 -

170 Bulletin Overload Relays Product Overview Overload Relays 0 Bulletin -EE -EC -EC/EC Type E Plus Electronic Overload Relay E Electronic Overload Relay E Plus Electronic Overload Relay Eutectic lloy Overload Relay Rated Current (Range) NEM Operating Voltage, Nominal 00V IEC Operating Voltage, Nominal 0/000V 0/000V Overload Type Solid-State Microprocessor-Based Microprocessor-Based Euctectic lloy Trip Class (Fixed) 0, 0, 0 Trip Class (djustable) 0,, 0, mbient Temperature Compensated Reset Type utomatic and Manual utomatic and Manual utomatic and Manual Manual Only djustment Range : : : Phase Loss s djustable Delay djustable Delay Ground (Earth) Fault Optional Sensitive Overcurrent (Jam) Detection Optional Stall Detection Underload Detection Current Imbalance PTC Thermistor Monitoring Optional Warning Settings N.C. Trip Contact N.O. larm Contact (Option) No. of Outputs No. of Inputs ODV (DeviceNet) Optional Conformance Variable Frequency Drive (VFD) Compatible Product Selection Page - Page - Page - -0

171 Bulletin E Plus Solid-State Overload Relays Overview/Product Selection E Plus Solid-State Overload Relays 0. 0 Current Range Single- and Three-Phase Devices Self-Powered Phase Loss Protection Wide djustment Range (:) Insert-Molded Power Connections N.O. and N.C. Isolated uxiliary Contacts (B00 Rated) Low Energy Consumption (0 mw) mbient Temperature Compensation Visible Trip Indication Selectable Trip Class (0,, 0, or 0) Selectable Manual/uto-Manual Reset Table of Contents Product Selection... this page pproximate Dimensions... - Standards Compliance IEC EN 0-- EN 0-- CS., No. UL 0 Certifications culus Listed (File No. E0, Guide No. NKCR, NKCR) Bulletin -EE Three Phase Devices Selectable Trip Class (0,, 0, 0) Selectable Manual/uto-Manual Reset Mounts to Contactor djustment Range EET -EEBT -EECT -EEDT -EEBC -EECC -EEDC -EEEC -EEFC -EEFD 0 -EEGD 0 0 -EEHE EEKF Bulletin S-EE Single-Phase Devices Selectable Trip Class (0,, 0, 0) Selectable Manual/uto-Manual Reset Mounts to Contactor djustment Range S-EEPT S-EERT S-EEST S-EEPC S-EERC S-EESC S-EETC 0 S-EEUD 0 -

172 Bulletin E Plus Solid-State Overload Relays pproximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Size 00 Size 0 0 Overload Contactor B C D F H H J -EE C Size 0 and -EE C Size -EE D Size (-/) 00 (-/). (-/) (-/) (-/). (-/) (-/) (-/) (-/). (/). (/). (/) (-/) (-/) 0. (-/) 0 (-/) (-/). (-/) 0 (-/) 0 (-/). (-/). (/). (/). (/) -

173 Bulletin E and E Plus Solid-State Overload Relays Product Overview/Selection Bulletin Bul. -EC 0. 0 Current Range DeviceNet Ready (ODV Conformance Tested) LED Indicators and Test/Reset Button djustable Trip Class 0 mbient Temperature Compensation True RMS Current Sensing (0 0 Hz) Protection for Single- and Three-Phase Motors Integrated I/O ( In / Out) Programmable Trip and Warning Settings Diagnostic Functions (History of Last Trips) Bul. -EC and -EC also include: Integrated I/O ( In / Out) Ground Fault Protection PTC Thermistor Monitoring DeviceLogix Component Technology (series B only) Table of Contents Product Selection... this page ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance EN 0--, EN 0-- CS., No. UL 0 UL 0 Certifications CE culus (File No. E0, Guide No. NKCR, NKCR) (File E, Guide No. KDX) C-tick BS Description The E Overload Relay is a multi-function solid-state microprocessor-based electronic overload relay for the protection of single- or threephase squirrel cage induction motors. In addition to providing ambient compensated overload protection, the E Overload Relay also includes advanced features such as warning diagnostics, variable frequency and true RMS current sensing, I/O capabilities, and direct DeviceNet connectivity. The E Plus Overload Relay offers the added features of zero sequence (core balance) ground fault protection, PTC thermistor input, and additional I/O capabilities. Catalog Number Explanation EC B T Code EC EC EC a b c a Type Description E E Plus E Plus Product Selection Your order must include ) the of the overload relay selected, and ) if required, of any accessories. Bulletin -EC Electronic Motor Protection Relays Direct Contactor Mount Inputs Output For Installation on NEM Starter Size djustment Range ECPT 00 -ECT -ECBT ECPC -ECC 0 -ECBC -ECCC -ECDC -ECDD 0 -ECED 0 -ECFE 0 0 -ECHF b djustment Range [] Code Description P 0..0 B C D E 0 F 0 H 0 0 Bulletin -EC and -EC Electronic Motor Protection Relays Direct Contactor Mount Inputs/ Outputs PTC Thermistor Input Ground Fault Sensing DeviceLogix (series B) c Bulletin 00 Contactor Size Code Description T Size 00 C Size 0 D Size E Size F Size For Installation on NEM Starter Size djustment Range ECPT 00 -ECT -ECBT ECPC -ECPC -ECC -ECC 0 -ECBC -ECBC -ECCC -ECCC -ECDC -ECDC -ECDD 0 -ECED -ECED 0 -ECFE 0 0 -ECHF For applications greater than 00, see the Bulletin panel mount devices for use with external current transformers. 0 -

174 Bulletin Eutectic lloy Overload Relays Product Overview/Product Selection Eutectic lloy Type Bulletin Rockwell utomation exclusive overload relay is the same for all three trip classes (0, 0, and 0) for each Starter Size. Trip current ratings are easily selected by choosing the proper heater element no need to change the overload relay. The trip free mechanism means you still have overload protection even if the reset button is held down. Bulletin overload relay is a manual reset, eutectic alloy, thermal type overload device. When coordinated with the proper short circuit protection, the overload relay is intended to protect the motor, motor controller, and power wiring against overheating due to excessive overcurrents. ll Bulletin block type relays are furnished with an OPTICL INDICTOR which becomes visible when the relay has tripped. manual contact test module is provided as standard on block type Bulletin overload relays. One N.O. or N.C. auxiliary contact may be field added to block type Bulletin overload relays. This extra contact module physically replaces the contact test module. Table of Contents Product Selection... this page ccessories... - Modifications... - pproximate Dimensions... - Standards Compliance UL 0 CS. No. CE Mark Certifications UL Listed (File No. E0, Guide No. NKCR) CS Certified (File No. LR) 0 Product Selection Eutectic lloy Type Manual Reset, Starter Mount STRTER MOUNT For installation on Rockwell utomation NEM starters. Heater Elements Overload relays require or overload heater elements. See page - for heater element selection. Starter Size Number of Poles N.C. Contact Open Type without Enclosure Eutectic lloy Type Manual Reset, Panel Mount PNEL MOUNT For installation and wiring separate from the contactor. Heater Elements Overload relays require or overload heater elements. See page - for heater element selection. Type Compact Standard Current Transformer Type Eutectic lloy, Manual Reset Heater Elements Overload relays require overload heater elements. See page - for heater element selection. N.O.-N.C. Contact 00 (Series B & D) -JOV -JOV 0, -BOW -BOW -COW -COW -DOW -DOW -EOW -EOW Maximum Continuous Current () Number of Poles Open Type without Enclosure Type General Purpose Enclosure N.C. Contact N.O.-N.C. Contacts N.C. Contact N.O.-N.C. Contacts -JOV -JOV -KOV -KOV 0 -BOV -BOV -BOV -BOV -BV -BV -COV -COV -COV -COV -CV -CV -DOV -DOV -EOV -EOV For Renewal Part Overload Relay used on starter mounted devices, see page page -. Full Load Current Range () Lug Kits Terminal lugs are not included. Can be applied up to 00V TPD00 -LF TPD00 -LG 0 -TPD00 -LH 0 0 -TPD0 -LJ -

175 Bulletin Eutectic lloy Overload Relays pproximate Dimensions Open Type without Enclosure for Bulletin Eutectic lloy Type Manual Reset Panel Mount Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Maximum Current [] No. of Poles / 0 Wide -/ (.) / (.) -/ (00) / (.) -/ (00) -/ () B High -/ (.) -/ (.) -/ (.) -/ (0) -/ () C Deep D E F G H J K -/ (.) -/ (0.) -/ () -/ (0.) -/ () -/ () -/ (.) -/ () -/ (.) -/ () -/ () -/ (0) / () / (.) / () - -/ (0) -/ (0) -/ (.) -/ () -/ (.) / (.) -/ (0) -/ (0) -/ (0) -/ (0) -/ (.) -/ (.) -/ () -/ (.) -/ (.) / (.) / (.) / (.) -/ () -/ () -/ () -/ () -/ (0) -/ (0) -/ (.) Open Type without Enclosure for Bulletin Current Transformer Type Eutectic lloy, Manual Reset -/ (.) / (.) / (.) -TPD00 -TPD00 -TPD00 -TPD0 Wide -/ () -/ (.) -/ (.) -/ (0) B High -/ () -/ () 0-/ () -/ (0) C Deep D E F G H J K -/ (.) -/ () -/ () -/ () -/ (0) -/ (0) -/ (0) -/ (0) Mounting holes for Cat. Nos. -TPD00 and -TPD0 only. -/ (0) -/ () -/ () -/ () / (.) / (0.) / (0.) / () -/ () -/ (.) -/ (.) -/ () / () / () / () / (0) / (0) / (0) / (0) / (0) / (.) / () / () / () 0 -

176 Bulletin Eutectic lloy Overload Relays pproximate Dimensions, Continued Type General Purpose Enclosure for Bulletin Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Maximum Current [] Bulletin 0 0 Wide -/ () B High 0-/ (0) C Deep D E F G -/ () -/ (0) -/ (0.) / (.) -/ () 0 -

177 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters Δεσχριπτιον Type W Heater Elements Eutectic lloy Overload Relay Heater Elements Type J CLSS 0 Type P CLSS 0 (Bul. 00 ONLY) Type W CLSS 0 Type WL CLSS 0 Description Overload Relay Class Designation United States Industry Standards (NEM Part ICS -) designate an overload relay by a class number indicating the maximum time in seconds at which it will trip when carrying a current equal to 00 percent of its current rating. Class 0 overload relay will trip in 0 seconds or less at a current equal to 00 percent of its rating. Class 0 overload relay will trip in 0 seconds or less at a current equal to 00 percent of its rating. Class 0 overload relay will trip in 0 seconds or less at a current equal to 00 percent of its rating. llen-bradley standard overload relay protection is provided using Type W heater elements for the 00 Line. This provides Class 0 operation and is recommended for General pplications. Specific pplications may require Class 0 or Class 0 overload relays. Class 0 overload relays are often used with hermetic motors, submersible pumps, or motors with short locked rotor time capability. Class 0 overload relays should be used with motors driving high inertia loads, where additional accelerating time is needed and the safe permissible locked rotor time of the motor is within Class 0 performance requirements. For applications requiring Class 0 protection, Type WL heater elements are available. To order, use the applicable Type W selection table, follow the heater element selection instructions and change the W in the Heater Type Number to WL. For applications requiring Class 0 overload relays, Type J elements are available. See page page -0 for Index to Heater Element Selection Tables. Heater Element Selection The Full Load mperes listed in the tables are to be used for heater element selection. For Type J and W Heater Elements, the rating of the relay in amperes at +0 C (+0 F) is % of the Full Load mperes listed for the Heater Type Number. For Type WL Heater Elements, the rating is 0% of the Full Load mperes listed for the Heater Type Number. Refer to the motor nameplate for the full load current, the service factor, and/or the motor classification by application and temperature rise. Use this motor nameplate information, the application rules, and the Full Load mperes listed in the proper table (see Index) to determine the Heater Type Number. Table of Contents Overload Relay Class Designation... this page Heater Element Selection... this page mbient Temperature Correction... this page Heater Element Selection Procedure. this page Time Current Characteristics... - Index to Heater Element Selection Tables The following is for motors rated for Continuous Duty: For motors with marked service factor of not less than., or motors with a marked temperature rise not over +0 C (+0 F), apply application rules through. pply application rules and when the temperature difference does not exceed +0 C (+ F). When the temperature difference is greater, see below.. The Same Temperature at the Controller and the Motor Select the Heater Type Number with the listed Full Load mperes nearest the full load value shown on the motor nameplate.. Higher Temperature at the Controller than at the Motor If the full load current value shown on the motor nameplate is between the listed Full Load mperes, select the Heater Type Number with the higher value.. Lower Temperature at the Controller than at the Motor If the full load current value shown on the motor nameplate is between the listed Full Load mperes, select the Heater Type Number with the lower value. For motors with Marked Service Factor of less than., select the Heater Type Number one rating smaller than determined by the rules in paragraphs, and. Motors rated for Intermittent Duty Please contact your local Rockwell utomation sales office or llen-bradley distributor for additional information. Heater Element Selection Procedure When Temperature at Controller is ±0 C (± F) Greater than Temperature at Motor mbient Temperature Correction The ambient temperature at the motor and controller is the same in most applications. Under this condition, the overload relay is designed to sense changes in ambient temperature and also protect the motor over a range of temperatures. Output that a motor can safely deliver varies with temperature. The motor can deliver its full rated horsepower at an ambient temperature specified by the motor manufacturers, normally +0 C (+0 F). t high temperatures (higher than +0 C) less than 00% of the normal rated current can be drawn from the motor without shortening the insulation life. t lower temperatures (less than +0 C) more than 00% of the normal rated current could be drawn from the motor without shortening the insulation life. Thus, there is an inverse relationship between motor ambient temperature and motor output. In any motor, allowable output decreases as the ambient temperature is raised and vice versa. 0 -

178 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued Heater Element Selection Procedure When Temperature at Controller is ±0 C (± F) Greater than Temperature at Motor (Continued) mbient Temperature Correction Curve (See Performance Data, page Important ) Referring to the Type W ambient temperature correction curve on this page for a motor at + C ambient, the motor correction factor (C.F. motor) is shown to be 0%. The correction factor for the starter ambient temperature is 00% since it is at +0 C. Thus, Now, using this correction factor, the readjusted full load current value can be determined by: 0 When the temperature difference between the motor and controller does not exceed +0 C the heater elements should be selected according to the directions given in the Heater Element Selection, page -. When the temperature difference is more than +0 C an ambient temperature correction factor should be used as part of the process for selecting heater elements. The ambient temperature correction curve shown below shows the factor by which heater selection rating changes with ambient temperature changes. Heater Element Selection Procedure In solving problems where ambient temperature correction is necessary, the following simple procedure is recommended:. First find the correction factor ratio ( C.F.R. ). This is the ratio of correction factor of the motor ambient temperature (C.F.m) to the correction factor for the controller ambient temperature (C.F.c). The formula for calculating the correction factor ratio is: Both correction factors are selected from the curve for the type of heater element to be used. The heater element selection tables are based on a +0 C ambient temperature. This means the correction factor for a +0 C is.00. In other words, there is no correction factor at +0 C.. Next in this heater element selection process is to adjust the motor nameplate full load current (FLC) by the C.F. Ratio. This readjusted value of motor nameplate full load current (FLC) is the yardstick in selecting the proper heater element.. The last step is to refer to the suggested heater element table and pick the element whose rating for the given controller size is closest to FLC. Examples To become familiar with this heater element selection process, consider a few examples. Example. Starter at Normal +0 C mbient Motor Lower. -Phase, C, squirrel cage motor, Hp, 0V, 0 Hz, 00 rpm, FLC of, service factor., Temperature at starter +0 C, Temperature at motor + C, Type W heater elements will be used. In Example, the motor is at a much cooler ambient temperature (+ C) compared to the controller which is at the normal +0 C. Because the motor is normally rated for use at +0 C, it will deliver a little more than its rated horsepower. This means that a heater element with a higher than normal motor nameplate full load current rating can be used. Bulletin, Size, was specified for this application. The directions for heater element selection indicate that Table should be used. The table shows that. falls between two values,.0 (W) and.0 (W). Because.0 is closer to the requirement, select the heater element W. Example. Starter at Normal +0 C mbient Motor Higher. Phase C, squirrel cage motor, Hp, 0V, 0 Hz, 00 rpm. FLC of, service factor.. Type W heater elements, Temperature at starter +0 C, Temperature at motor + C. This represents a situation where the motor ambient temperature is higher than +0 C. In this example, the motor is at + C ambient temperature and the controller is at +0 C. When the motor is functioning in a warmer environment than the controller it will not be able to deliver the normal horsepower. To protect it from damage, it becomes necessary to downsize the heater element compared to the same motor operating in a +0 C ambient temperature. Referring to the Type W ambient temperature correction curve, the correction factor would be: Having determined the correction factor, the current rating to be used when selecting a heater element would be: For Bulletin, Size, again refer to Table. The value of 0. falls between 0.0 (W) and. (W). Since 0.0 is closer to 0. specify the W heater element. Example : Starter Lower than +0 C Motor Higher. -Phase, C, squirrel cage motor, Hp, 0V, 0 Hz, 00 rpm. FLC of, service factor.. Type W heater elements, Temperature at starter + C, Temperature at motor + C. Next, consider a case where both the controller and the motor are at ambient temperatures other than +0 C. In Example the temperature of the controller is + C ambient (cooler) while the temperature of the motor is + C ambient (warmer). s stated earlier, a motor running in a warmer environment will deliver less than its normal horsepower. This requires downsizing the heater element rating. The controller in this case is in a cooler environment which prevents the heater element from heating up as much as in a +0 C ambient temperature. This also requires downsizing the heater element rating to provide adequate protection. Thus, the net effect of a warmer motor and a cooler controller is to further downsize the heater element. Using the Type W temperature correction curve, the correction factor in this case is: The readjusted value of current FLC for this example is: Table shows that this value falls between.0 (W) and 0.0 (W). Because.0 is closer to the requirement, select the heater element W. -

179 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued Heater Element Selection Procedure, Continued Example : Starter bove +0 C Motor Lower. -Phase, C, squirrel cage motor, Hp, 0V, 0 Hz, 00 rpm. FLC of, service factor.. Type W heater elements, Temperature at starter + C, Temperature at motor + C. Now, consider the effect of a controller in a warmer environment and a motor in a cooler environment. In Example, the controller is at + C ambient (warmer) and the motor at + C ambient (cooler). s mentioned earlier, a motor at a cooler temperature can deliver more than its normal horsepower. The controller when in a warmer environment will heat up faster causing the eutectic alloy to melt before the normal overload condition. This requires upsizing the heater element rating. Referring to the Type W ambient temperature correction curve (page -), the correction factor in this case is: This correction factor allows a heater element with current rating of: Referring to Table, this value of. falls between 0. (W) and. (W). Because 0. is closer to the requirement, select heater element W. Example : Starter bove +0 C Motor bove. -Phase, C, squirrel cage motor, Hp, 0V, 0 Hz, 00 rpm. FLC of, service factor.. Type W heater elements, Temperature at starter + C, Temperature at motor +0 C. Next, take an example where both the controller and the motor are both warmer than +0 C ambient temperature but their ambient temperatures are different. For instance, the controller could be at + C ambient and the motor is at +0 C ambient. Since the difference in their ambient temperatures is greater than +0 C an ambient temperature correction must be made. In Example the correction factor is given by: Time Current Characteristics at +0 C (+0 F) (See Performance Data, page Important- This means that the rating of the heater element should be 0% of the normal nameplate motor full load current or: For Bulletin, Size controller, Table shows this rating to fall between 0.0 (W) and. (W). Because. is closer, select heater element W. Note here that the net effect has been to downsize the heater element rating compared to a normal +0 C ambient operation. Note: The heater element selection tables are designed to accommodate motor service factors of. or greater, as given in all the preceding examples. If the service factor had been less than. (for example, S.F. =.0) a heater element one rating smaller than selected in each example would have been the correct choice. This would provide protection at 0% lower current levels. 0 -

180 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued Index to Heater Element Selection Tables 0 Bulletin Number Encl. Type 0, 0 Open 0 0 Open,, R// Open, R//, /X Table No. Manual Reset Type W Element Type J Element Size Relay, Ø Relays, Ø Relay, Ø Relays, Ø /X 0 0 X 0 0 Unilock R/ & 0 Bolted 0 0 R/ &, & 0V Open 0 0, 0, R/, 0 /X, X 0, R//,/X, X Bolted 0 0 R/ &, & 0 Open,, R/ Open 0, P 0, R// with control, R// 0, P 0 transformer 0 Open,, R// 0 Open,, R//, /X 0 Open, R//, /X 0 0 /X 0 X 0 0 Unilock 0 R/ & Bolted 0, P 0 R/ &, & 0, R//, /X, X M R// 0 0, R//, /X, X Unilock 0 R/ & Bulletin Number Encl. Type Size Type W Element Relay, Ø Table No. Manual Reset Relays, Ø Type J Element Relay, Ø Relays, Ø Bolted 0 R/ &, 0 & Open,, R// 0 /X 0 0 X 0 Bolted 0 0E R/ &, & Bolted 0 0F & G R/ &, & PW PW 0 PW PW 0 PW PW PW PW YD YD 0 YD YD YD YD 0 Open with current Open transformer 00 ll (Type P) 0, 0RS, 0TS, ll 0 P 0 0U, 0TU 0 X, X, When selecting heater elements for Bulletin 0, divide the motor nameplate full load amperes by.00 use this value to select the proper Heater Element. When selecting heater elements for Bulletin 0, divide the motor nameplate full load amperes by. use this value to select the proper Heater Element. -0

181 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Element Full Load mperes P 0. P 0. P 0. P 0. P 0. P 0. P 0. P 0. P 0. P0 0. P 0. P.0 P. P.0 P. P. P. P. P. P0.0 P. P. P.0 P. P. P. P. P. P. P0.0 P. P. P. P.0 P.0 P 0. P.0 P. P. TBLE Heater Element Full Load mperes Size 00 Size 0 Size Size P Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J... J... J... J... J J... J J... J... J... J J... J... J J... J... J0... J J... J... J... J... J J J.0.0. J... J0... J... J.... J.. 0. J... J..0. J.0.. J..0. J.0.0 J J J. J J J J J J0 0 J J J J 0 Refer to Heater Element Selection Procedure on page - before using tables. -

182 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued 0 TBLE 0 Heater Element Full Load mperes Size 0 Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. W.0.0 W.0.0 W.. W.. W.0.0 W0.. W.. W.. W.. W.. W.. W.. W.. W.. W.. W0.0.0 W.. W W.. W.. W.0.0 W.. W.. W.. W. W0. W. W. W.0 TBLE Heater Element Full Load mperes Size 0 Size Size P W W W W W W W W W W W W W W W W W W.0.0 W.. W.. W0.. W.. W.. W.. W.0.0 W.. W.. W.. W.0.0 W.. W0.. W.0.0 W.. W.. W.. W.. W.. W.. W.. W.. W0.. W W... W... W... W... W... W... W.. W.. W0.. W.0.0 W.. W.0 W.0 W.0 Refer to Heater Element Selection Procedure on page - before using tables. -

183 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Element Full Load mperes Size 0 Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.0.0 J.. J0.. J.. J.. J.. J.. J.. J.. J.0.0 J.. J.. J0.0.0 J.0.0 J.. J.0.0 J.. J.. J.0.0 J J.0.0 J.. J0.. J.. J.. J.. J 0. J. J. J. J J J0 TBLE Heater Element Full Load mperes Size 0 Size Size P JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.. J.. J.. J.. J.. J.. J0.0.0 J.. J.. J.. J.0.0 J.. J.0.0 J.0.0 J.. J.0.0 J0.. J.. J.. J.. J.. J.. J J.. J... J... J0... J... J... J J.. J.0.0 J.. J 0.0 J. J.0 J0 0 Refer to Heater Element Selection Procedure on page - before using tables. -

184 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued 0 TBLE Heater Element Full Load mperes Size 00 W0 0. W 0. W 0. W 0. W 0.0 W 0. W 0. W 0. W 0. W 0.0 W0 0. W 0.0 W 0. W 0. W 0. W 0. W 0. W.0 W. W. W0. W.0 W. W. W.0 W. W. W. W.00 W. W0. W.0 W. W. W. W.0 W. W. W.0 W.0 W0.0 TBLE Heater Element Full Load mperes Size Size J 0 J 0 J J0 0 J 0 J 0 0 J J 0 0 J J 0 J 0 J J 0 0 J0 0 0 J 0 0 TBLE Heater Element Full Load mperes Size Size W W0 W 0 W W 0 W 0 0 W W W 0 W 0 W 0 W0 0 0 W 0 W 0 W 0 0 W W TBLE Heater Element Size W 0 W0 W W 0 W 0 W 0 W 0 W W 0 W 0 W 0 W0 0 W 0 W 0 W 0 W Refer to Heater Element Selection Procedure on page - before using tables. -

185 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Element Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W W.0.0 W0.0.0 W.. W.. W.. W.. W.. W.. W.. W.. W.. W0.0.0 W.0.0 W.. W.. W.. W.. W...0 W.0.0. W.0.0. W... W0... W... W... W W... W... W... W... W... W... W0. 0. W... W... W W W W W... W.0 W 0. W0. W.0 W W W W W 0 0 W W 0 0 W 0 W0 W W W 0 W W TBLE Heater Element Full Load mperes Size 0 Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. W.0.0 W.. W.. W.. W.0.0 W0.. W.. W.0.0 W.. W.0.0 W... W... W...0 W... W... W0... W.0.0. W.. 0. W W... W... W... W... W... W... W W..0 W.0.0 W.. W.. W.0 W. W.0 W. W.0 W0 W W W W W W W W W W0 W W W W W 0 -

186 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued 0 Heater Element TBLE Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. W.0.0 W.. W.. W.. W.0.0 W0.. W.. W.0.0 W.. W.0.0 W... W...0 W...0 W... W... W0...0 W.0.0. W.. 0. W W... W... W.0.0. W... W... W... W0. 0. W... W... W W W.0.0. W W... W.0.0 W. W0.0 W W W W W W 0 0 W W 0 0 W 0 W0 W W W 0 W TBLE Heater Element Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. W.. W.. W.. W.0.0 W.. W0.. W.. W.. W.. W.. W... W... W.0.0. W... W... W0... W.0.0. W W W.... W W.... W..... W W W W.... W....0 W W W...0 W W.0..0 W 0.. W. 0.0 W0..0 W.0 W.0 W.0 W.0 W.0 W.0 W.0 W 0.0 W 0 W0 W W W W W -

187 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Element Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. W.0.0 W.. W.. W.. W.0.0 W0.. W.. W.0.0 W.. W.0.0 W... W...00 W...0 W...0 W... W0... W W W W.... W.... W W..... W W W W.... W W W....0 W..0. W W.0.0. W W..0.0 W W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0 0 W W0 W W W W TBLE 0 Heater Element Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W W.0.0 W0.. W.. W.. W.. W.. W.0.0 W.0.0 W.. W.. W.. W0.0.0 W.. W.. W.0.0 W.. W... W... W.0.0. W... W... W0... W... W W W.... W.... W W..... W W W W.... W W W W.0.0. W...0 W.0..0 W...0 W..0.0 W W W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W 0 W W0 W W W W W 0 -

188 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// 0 Heater Element TBLE Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. W.. W.. W.. W.0.0 W.. W0.. W.. W.. W.. W.. W... W... W.0.0. W... W... W0... W.0.0. W W W.... W W.... W.... W.... W W W W.... W W...0 W...0 W W.0.0. W..0.0 W..0.0 W W.0.0 W.0.0 W W.0.0 W W.0.0 W.0.0 W 0 W 0 W0 W W 0 W W W TBLE Heater Element Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.0.0 W.. W.. W.. W.0.0 W.. W0.. W.. W.. W.. W.. W... W... W... W...0 W... W0... W...0 W W.... W.... W.... W W..... W W W W.... W W W W.0.. W W..0.0 W...0 W W0.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0 0 W 0 W W0 W 0 W W -

189 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued TBLE Heater Element Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W..0 W.. W.. W.. W.. W..0 W0.. W..0 W.. W.. W.. W... W... W..0. W... W... W0... W.0.0. W W.0.. W.... W.... W...0. W.0... W W W W.... W W W W... W.0..0 W.0..0 W W W W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W.0.0 W W W0 W W W W Heater Element TBLE Full Load mperes Size 0 Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.0.0 W.. W.. W.0.0 W.0.0 W.0.0 W.. W.. W.. W.. W0.. W.. W.. W.0.0 W.. W... W... W... W W... W0... W... W W.... W.... W W.... W..... W W.... W W.... W.... W.... W... W W... W.0.. W.0. W W0 W W 0 W 0 W W W W 0 W W 0 W0 W W W W W 0 -

190 0 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued TBLE Heater Element Full Load mperes Size 0 Size Size P Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.0.0 W.. W.. W.0.0 W.. W.0.0 W.. W.. W.. W.. W0.0.0 W.. W.0.0 W.. W.0.0 W... W W... W... W... W0... W... W W..... W..... W W..... W..... W W.... W0.... W....0 W.... W.... W W..0. W.0..0 W.0..0 W. 0 W.0 W0 W W 0 W W W W W W W W0 Refer to Heater Element Selection Procedure on page - before using tables. -0 TBLE Heater Element Full Load mperes Size 0 Size Size P Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.0.0 W.. W.. W.. W.0.0 W.0.0 W.. W.. W.. W.0.0 W0.. W.. W.. W.. W.0.0 W... W... W... W.0.0. W...0 W0... W.0.0. W W..... W W..... W..... W W W W W..... W W W W W W..0. W.0 W W0 W W W 0 W W W 00 W 0 W W W0 W W W W W

191 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued TBLE Heater Element Full Load mperes Size 0 Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.0.0 J.. J0.. J J.0.0 J.. J.. J.. J.. J.. J.. J.. J0.. J.. J.. J.. J.. J.. J.0.0. J... J J... J0...0 J... J... J... J.... J 0... J... J... J.0... J..0 J J.0.0 J.0 J.0 J 0 J J J0 0 J J J 0 J J J J Refer to Heater Element Selection Procedure on page - before using tables. TBLE Heater Element Full Load mperes Size 0 Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.0.0 J.. J0.. J J.0.0 J.. J.. J.. J.. J.. J.. J.. J0.. J.. J.. J.. J.. J.. J.0.0. J... J J... J0... J... J... J... J J 0... J... J.... J J J J.0..0 J.. J.0 J.0 J J 0 J0 J 0 J J 0 J J J 0 0 -

192 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued 0 TBLE 0 Heater Element Full Load mperes Size 0 Size Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.. J.. 00 J0.. 0 J.0.0 J.. J.. J.. 0 J.0.0 J.. J.. J.0.0 J.. 0 J0.. 0 J.. J.. J J... J... J... J... J J... J0... J... J.0.0. J... J J... J... J... J J... J J.0.0. J. 0 J J J J J0 0 J J J 0 J J J Refer to Heater Element Selection Procedure on page - before using tables. TBLE Heater Element Full Load mperes Size 0 Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.. J.. J0.. J.0.0 J.. J.. J.0.0 J.. J.. J.. J.. J.. J0.. J.. J.. J.. J.. J.. J... J.. 0. J J... J J... J... J... J J... J... J... J...0. J... J J J.0 0 J. J J 0 J J0 0 J J 0 J J J -

193 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued TBLE Heater Element Full Load mperes Size 0 Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.0.0 J.. J0.. J J.0.0 J.. J.. J.. J.. J.. J.. J.. J0.. J.. J...0 J... J... J... J...0 J J J... J J... J... J... J J... J... J... J J..0. J J.0.. J.0. J J 0 J J J0 J J J 0 J J J Refer to Heater Element Selection Procedure on page - before using tables. TBLE Heater Element Full Load mperes Size 0 Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.. J.. J0.. J.0.0 J.. J.. J.. J.0.0 J.. J.. J.0.0 J.. J0.. J.. J.. J J... J... J...0 J.. 0. J J... J0... J... J.0.0. J... J J... J... J... J J..0. J J.0..0 J. J J J J J0 J J 0 J J J 0 -

194 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued 0 TBLE Heater Element Full Load mperes Size 0 Size Size P Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J.0.0 J.. J.. J.. J.. J.. J0.. J.. J.. J.0.0 J.. J.. J.. J.. J.. J.. J0.0.0 J.. J.. J... J... J... J... J J.... J.... J J.... J.... J....0 J J.... J.... J.... J 0... J.0.0. J J..0 J.0 J J J J J0 J J J J J TBLE Heater Element Full Load mperes Size J 0 J J J 0 J 0 J0 J 0 J J 00 J 0 J 0 J 0 J 0 J 0 J Refer to Heater Element Selection Procedure on page - before using tables. -

195 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued TBLE Heater Element Full Load mperes Size 0 Size Size Size Size Size W W W W W W W W W W W W W W W W W W W W.0.0 W0.. W.. W.0.0 W.. 00 W W.. W.0.0 W.. W.. W.. W0.. W.. W.. W.. 0 W.. W.0.0. W.0.0. W... W.0.0. W... W0... W.0.0. W... W W W... W... W... W... W.0.0. W0... W W... W... W.0... W 0..0 W W.0. W..0.0 W W W..0.0 W W.0.0 W.0.0 W.0.0 W W.0.0 W.0 0 W 0 W0 W W W W W Heater Element TBLE Full Load mperes Size 0 Size Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. W0.. W.. W.. W.. W.. 0 W.. W.. W.. W.. W.. W0.0.0 W.. W.. 0 W.. W... W...0 W...0 W...0 W...0 W... W0... W.0.0. W... W.. 0. W W... W... W...0 W... W.0.0. W0... W 0... W...0 W W W...0 W W...0 W.0..0 W W W W W.0.0 W.0.0 W.0.0 W W.0.0 W.0 0 W 0 W0 W W W W W 0 -

196 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued 0 TBLE Heater Element Full Load mperes Size 0 Size Size Size Size Size W W W W W W W W W W W W W W W W W W W.0.0 W.. 0 W0.. W.. W W.. W.. 0 W.. W.0.0 W.. W.. 0 W.. W0.. W.. W.. 0 W.. 0 W... W... 0 W... W... W.0.0. W... W0...0 W...0 W W... W... W... W... W... W... W... W0... W...0 W..0. W.. 0. W W.0..0 W W.0..0 W W. W0.0 W W W W W W W W W 0 W0 W W W W TBLE Heater Element Full Load mperes Size W 0 W0 W W W W 00 W 0 W W W 0 W W0 W W W 0 W Refer to Heater Element Selection Procedure on page - before using tables. -

197 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0////////, Continued Heater Element TBLE Full Load mperes Size 00 Size 0 Size Size Size Size Size W W W W W W W W W W W W W W W W W W W W... W0... W... W... W W... 0 W... W W... 0 W... W... W W W... W... W... W W... W W... W... W W.... W W W.... W.... W.... W.... W.... W W0.... W W... W..0. W...0. W W W.0.0. W W W0.0 W W W W 0 W W 0 0 W W 0 W 0 W0 W W W TBLE Heater Full Load mperes Element Size 0 Size Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J J.. J.. J.. J.. J.. J0.. J.. J.. J.0.0 J.. J.. J.. J.. J.. J.0.0 J0.. J.. J.. J.. J.0.0 J...0 J...0 J... J J.... J0.... J J.... J J J 0... J... J.... J....0 J.0.0. J J J.0 J.0 J J J J0 J 0 J J 0 J J J 0 0 -

198 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued 0 TBLE Heater Element Full Load mperes Size W 0 W0 W W 0 W W 0 W W W W 0 W W0 W W 0 W 0 W W 0 TBLE Heater Element Full Load mperes Size J J J J 0 J J0 0 J J J 0 J J J J 00 J 0 J J0 J TBLE 0 Heater Element Full Load mps / /Size 00 W0 0. W 0.0 W 0. W 0. W 0. W 0. W 0. W 0. W 0.0 W 0. W0 0. W 0. W 0. W 0. W 0. W 0. W 0. W.0 W. W. W0. W.0 W.0 W.0 W.0 W.0 W. W.0 W. W.00 W0. W. W.00 W.0 W.00 W. W. W.0 W.0 W.00 W0. W.0 W 0. W. W.0 W. W. W. W.0 W 0.0 W0. W.0 W. W.0 W.0 Refer to Heater Element Selection Procedure on page - before using tables. -

199 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Full Load mperes Element Size Size Size 0 Size Size Size W W W W W W W W W W W W W W W W W W W..0.0 W... W0... W... W... W... W..0.0 W... W... W... W...0 W... W0... W... W... W... W... W... W... W... W... W... W0... W....0 W W.... W.... W.... W...0. W.... W.... W.... W W..... W W W W W W.0..0 W.0.. W.0.0 W0. W W W W 0 W W W 0 W 0 W 0 W0 0 W 0 W W 0 W 0 W TBLE Heater Element Full Load mps / /Size 00 JJ 0. JJ 0. JJ 0. JJ 0. JJ0 0. JJ 0.0 JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. J 0. J 0. J 0. J.0 J. J. J. J. J. J0. J.0 J.0 J.0 J. J.00 J. J. J.0 J. J0. J.0 J.0 J.0 J.0 J. J.0 J. J.0 J. J0. J.0 J.0 J. J 0. J.0 Refer to Heater Element Selection Procedure on page - before using tables. 0 -

200 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued 0 TBLE Heater Full Load mperes Element Size Size Size 0 Size Size Size JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ J J J J J... J.0.0. J... J... J.0.0. J0... J...0 J.0.0. J.0.0. J... J...0 J.0.0. J... J J... J0... J... J... J J.0.0. J... J....0 J J J J0.... J.... J...0. J.... J J.... J..... J.... J J J J..0. J J J.0.0 J.0.0 J J0.0.0 J.0 J.0 0 J 0 J J J 0 J J Heater Element TBLE Full Load mperes -BOV -COV -DOV JJ 0. JJ 0. JJ 0. JJ 0. JJ0 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. J 0. J 0. J 0. J.0 J. J. J. J. J. J0. J.0 J. J. J. J.0 J. J. J.0 J. J0. J. J. J.0 J. J. J.. J. 0. J 0.. J.. J0.. J.. J.0. J.. J. 0. J.. J... J... J J.0..0 J J J.. J 0 J J J J0 J J 0 J 0 J J J J J Cat No. -EOV -00

201 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Full Load mperes Element -BOV -COV -DOV -EOV W0 0.0 W 0. W 0. W 0. W 0. W 0. W 0. W 0. W 0. W 0. W0 0. W 0. W 0. W 0. W 0. W 0. W 0. W 0. W.0 W. W0.0 W. W. W.0 W.0 W.0 W. W. W. W. W0. W. W. W.0 W. W. W. W. W.0 W. W0. W.. W W.. W.. W.0. W.. W.. W.0. W.. W0.. W... W... W... W.0.. W W.0... W W.0.0. W.0 W0 W W 0 0 W 0 W W W W 00 0 W 0 W 0 0 W0 0 W W W W W 0 TBLE Heater Full Load mperes Element Size 0 Size Size 0 Size W0 0. W 0. W 0. W 0. W 0.0 W 0. W 0. W 0. W 0. W 0.0 W0 0. W 0.0 W 0. W 0. W 0. W 0. W 0. W.0 W. W. W0. W.0 W. W. W.0 W. W. W. W.00 W. W0. W.0 W. W. W. W.0 W. W. W.0 W.0.0 W0.0. W 0.. W.0. W.. W.. W.. W.. W.. W. 0. W.. W0... W... W W W... W..0.. W.0... W. 0 W W 0 W0 0 W W 0 W W W 00 0 W 0 W W W W0 W W 0 W 0-0

202 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued 0 Heater Element -TPD00 TBLE Full Load mperes -TPD00 0 -TPD00 NEM Size -TPD0 0 W W W W 0 W0 0 W W W 0 W 0 W 0 0 W W W 0 0 W 0 W0 0 0 W W 0 0 W W W W W 00 W 0 Heater Element -TPD00 TBLE Full Load mperes -TPD00 0 -TPD00 NEM Size -TPD0 0 J J 0 J 0 J0 0 J 0 J J J J 0 0 J 0 0 J 0 J 0 0 J J J 0 J 0 J 0 Exceeds 0 seconds at six times rating, providing Class 0 protection. Maximum element for NEM Size. Refer to Heater Element Selection Procedure on page - before using tables. Heater Element TBLE Full Load mperes Size 0 Size Size 0 Size JJ 0. JJ 0. JJ 0. JJ 0.0 JJ0 0. JJ 0. JJ 0.0 JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. JJ 0. J 0. J 0. J.0 J. J. J. J. J.0 J. J0.0 J. J. J. J.0 J. J. J.0 J. J. J0. J.0 J. J. J. J..0 J.0. J 0..0 J.0. J.. J0.. J.. J.. J 0.. J... J..0. J...0 J.0..0 J..0. J J J 0.0 J.0 J.0 J.0 J 0.0 J 0 J0 J 0 0 J 0 J J J 0 J J -0

203 Bulletin Eutectic lloy Overload Relays Heater Elements Selection For pplication on Bulletin 00/00/0//////// Line Starters, Continued TBLE Heater Element Full Load mps Size W W0 W 0 W W 0 W W W W 0 W W W0 W W W W W W W W W TBLE Heater Element Full Load mps Size J J J J J 0 J0 J J J J J J J J J J0 J Refer to Heater Element Selection Procedure on page - before using tables. 0-0

204 Bulletin 00 Single-Phase NEM Manual Starting Switches Product Overview Manual Motor Starters Features Bulletin U Type of Operator -Phase Motor Voltage Push Button / Toggle / Lever / Key Type of Operator -Phase Motor Voltage Push Button / Toggle Lever Enclosures NEM Type Standards Certifications Product Selection Single phase switch Used on compressors, fans, pumps, and table saws Single Pole: 0V C ( Hp) Two Pole: 0V C ( Hp) Single and -phase switches Contact position indicator Locking feature Reversing and -speed 0V C, 0 Hz ( Hp) 0V C, 0 Hz ( 0 Hp) Single and -phase switches Contact position indicator Locking feature Undervoltage protection 0V C, 0 Hz ( Hp) 0V C, 0 Hz ( 0 Hp),, &, R, /X, &, and, R, /X, &, and NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. EN0-- BS /. USCG CFR.0 UL Listed Enclosed Products Only (File No. E; Guide No. NLRV) UL Recognized Open Style Products (File No. E; Guide No. NLRV) CS Certified (File No. LR ) merican Bureau of Shipping (BS) CE Marked NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. EN0-- BS /. USCG CFR.0 UL Listed (File No. E; Guide No. NLRV) CS Certified (File No. LR ) merican Bureau of Shipping (BS) CE Marked NEM/EEMC ICS (Industrial Controls and Systems) UL 0 CS C., No. EN0-- BS /. USCG CFR.0 UL Listed (File No. E; Guide No. NLRV) CS Certified (File No. LR ) merican Bureau of Shipping (BS) CE Marked Page -0 Page -0 Page

205 Bulletin 00 Single Phase NEM Manual Starting Switches Overview/Product Selection Type General Purpose Enclosure with Neon Pilot Light Ratings Single Pole HP 0V C, HP V C, Open Type without Enclosure or Type General Purpose Enclosure Two Pole HP 0V C, HP V C, Open Type without Enclosure or Type General Purpose Enclosure, / HP 0V DC Description Bulletin 00 Starting and overload protection of small -phase C/DC motors used on the following: Unit heaters Fans Stokers Pumps Refrigeration compressors Bulletin 00 manual switches consist of a snap switch combined with a thermal overload device operating on the solder-ratchet principle. The switch is designed to prevent being held closed under a sustained motor overload. To reset the overload mechanism, the switch lever is moved to the OFF position. The motor can be restarted by pushing the switch lever to the ON position. pplications include compressors, fans and pumps. Your order must include: ) Cat. no. of the switch, ) Cat. no. of the heater element(s), and ) if required, cat. no. of any accessories. Standards Compliance Certifications UL 0 EN0-- CS C., No. Open Type Without Enclosure Includes Legend Plate Type General Purpose Enclosure Surface Mounting Selector Switch HP 0V C, HP V C, Open Type without Enclosure or Type General Purpose Enclosure Heater Element See page - for heater element selection table. Type General Purpose Enclosure Flush Mounting Includes Flush Plate but not Switch Box Stainless Steel Flush Plate Type Watertight Enclosure Type & Enclosure Class I, Groups C & D Class II, Groups E, F & G Divisions & Hazardous Locations Switch Only Toggle Type -Pole 00-TOX 00-TX 00-TQX -Pole 00-TOX 00-TX 00-TQX 00-TCX 00-TEX Key Type -Pole 00-TOX 00-TX 00-TQX Lever Type -Pole 00-TOX 00-TX Switch with Neon Pilot Light ( or 0V) Toggle Type -Pole 00-TOX 00-TX 00-TQX -Pole 00-TOX0 00-TX0 00-TQX0 Key Type -Pole 00-TOX0 00-TX0 00-TQX0 Toggle Type Switch with Incandescent Pilot Light -Pole V 00-TCD 00-TED -Pole 0V 00-TC 00-TE Switch and Hand-Off-uto Selector Switch (for use on C only) Toggle Type -Pole 00-TX 00-TQX 00-TCX 00-TEX Switch with Neon Pilot Light and Hand-Off-uto Selector Switch ( or 0V, C only) Toggle Type -Pole 00-TX 00-TQX Key Type -Pole 00-TX Two Switch Units in One Enclosure Toggle Type -Pole 00-TX0 00-TCX0 00-TEX0 Two Switch Units in One Enclosure Neon Pilot Light on Both Units ( or 0V) Toggle Type -Pole 00-TX 00-TQX Two Speed Switch Toggle Type -Pole 00-TX Two Speed Switch with Neon Pilot Lights ( or 0V) Toggle Type -Pole 00-TX 00-TQX Separate Cover and Switch ssembly Toggle Type -Pole 00-N Hand-Off-uto 00-N For use with Bulletin 00H, Type and, Series C or later bases. UL Listed Enclosed Products (File No. E; Guide No. NLRV) UL Recognized Open Style Products (File No. E; Guide No. NLRV) CS Certified (File No. LR ) Table of Contents ccessories Modifications pproximate Dimensions merican Bureau of Shipping (BS) CE Marked Hazardous Location: UL Listed (File No. E0) CS Certified (File No. LR ) 0-0

206 Bulletin 00 Single Phase NEM Manual Starting Switches ccessories Field-Installed/Modifications Factory Installed/pproximate Dimensions Description Pilot Light Replacement Bulb Incandescent (Mfg. Designation #0 PSB-0V) Note: Pilot lights as used on Bulletin 00 switches indicate whether the motor is running only if the switch is used to control the motor directly. If a thermostat, pressure switch, or some other pilot device controls the operation of the motor, the pilot light on the Bulletin 00 switch merely indicates whether the power is ON or OFF. NEM Enclosure Type,, and 00S-N0 Μοδιφιχατιονσ Modifications Factory-Installed Flange Seal (see applicable codes and laws) This option provides a Type rating in addition to maintaining a Type & integrity. dd the letter S to the end of the cat. no. Example: Cat. No. 00-TEXS. Conduit Openings (Type and Type & only) If two / in. ( mm) pipe taps (one on top and one on bottom) are required, add the number to the end of the cat. no. Example: 00- TEX. Note: Suffix is only an option for the Type and & enclosures. Note: ll single unit devices are provided with one / in. ( mm) pipe tap on the bottom. By reversing the switch base, the pipe tap can be located on the top. ll dual units are provided as standard with one / in. ( mm) pipe tap on top and two on the bottom with two threaded plugs included. If / in. (. mm) openings are required, reducers should be used. Drain In order to install a drain on single unit devices (i.e. Cat. No. 00-TEX) an additional conduit opening is required. See Conduit Openings above. Sealing Well with Integral Flange Seal for Type,, and To order this option insert the letter R at the end of the listed cat. no. Example: 00-TEXR. Sealing Well without Integral Flange Seal for Type and To order this option insert the letter K at the end of the listed cat. no. Example: 00-TEXK. pproximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure Locking ttachment (For Toggle Operated Only) Drain (For / in. ( mm) Conduit Opening) (Switches in the Type and Type and enclosures are supplied as standard with provisions for locking in the OFF or ON position.) 00-N and 00H-NP Flange Seal (Provides NEM Type rating for outdoor locations in addition to maintaining NEM Type and integrity) Note: n approved drain 00H-NP is required for condensation when this option is used (refer to local Electrical Code).,, and 00H-NP0 00- TOX TOX TOX Cat. Nos. 00- TOX0 TOX0 TOX 00- TOX 0 Sealing Well (See applicable codes and laws) (Not available for use with 00-TEX) Note: When using a sealing well with integral flange seal for NEM Type outdoor applications, an approved drain fitting must be provided (refer to local Electrical Code).,, and (With integral flange seal) wire: 00H-NPRD0 wire: 00H-NPRD and (Without integral flange seal) wire: 00H-NPD0 wire: 00H-NPD ll other devices with the pilot light option utilize a neon lamp. For replacement information consult your local Rockwell utomation sales office or llen-bradley distributor. (For Type enclosure use replacement bulb 0--) -0

207 Bulletin 00 Single Phase NEM Manual Starting Switches pproximate Dimensions Type General Purpose Enclosure Surface Mounting Type Watertight Enclosure; Type and Hazardous Locations Enclosure 00- TX TX TX Cat. Nos. 00- TX0 TX0 TX 00- TX Dimension in inches (Millimeters) Key Inserted -/ (.) Selector Switch -/ (0) Toggle Operator -/ () 00- TX TX0 Type General Purpose Enclosure Flush Mounting Cat. Nos. 00- TX TX 00- TX Cat. Nos. 00- TCX 00- TEX 00- TQX TQX TQX Cat. Nos. 00- TQX0 TQX0 TQX Cat. Nos. 00- TQX 00- TQX TQX Type Watertight Enclosure, Type & Type & Hazardous Locations Enclosure TCX TCX Cat. Nos. 00- TEX TEX0 00- TC TCD Cat. Nos. 00- TE TED Lever Type Dimension is -/ in. (. mm). This dimension may vary up to ±/ in. (. mm). Mounting holes should be located at time of installation using device as a template. -0

208 Bulletin 0 Single and Three Phase NEM Manual Starting Switches Overview/Product Selection 0 Open Type without Enclosure Type of Operator Phase Size Push Button Toggle Lever Push Button Toggle Lever Push Button Toggle Lever Push Button Toggle Lever Ø Ø Ø Ø DC DC Ø Ø Ø Ø Bulletin 0 Contact position indicator Locking features Wide range of enclosures: Open-type without enclosure, Type, and Type Bulletin 0 manual starting switches are designed for use on motor starting installations where remote push button control is not required and where undervoltage protection is not needed. The motor is started at full line voltage, and thermal type overload protection is provided. Bulletin 0RS manual starting switches are designed for manually reversing C polyphase motors; the Bulletin 0TS manual switches are designed for operating -speed, separate winding wye connected motors. These switches incorporate two of the standard Bulletin 0 manual starting switches mounted on a common base plate. mechanical interlock is provided to prevent both switches from being closed at the same time. Maximum Horsepower Rating C, 0 Hz Breather 0-N (Can be installed at the top of an enclosure.) Drain 0-N (Can be installed at the bottom of an enclosure.) Breather-Drain Combination 0-N (Can be installed at the top of an enclosure as a breather or bottom as a drain.) Table of Contents Product Selection... - ccessories and Modifications... - pproximate Dimensions... - Your order must include: ) Cat. no. of the switch, ) Cat. no. of the heater element(s), and ) if required, cat. no. of any accessories. Standards Compliance Certifications NEM/EEMC ICS UL Listed (File No. E; CE Marked (Industrial Controls and Systems) Guide No. NLRV) Hazardous Location: UL 0 EN0-- CS Certified (File LR ) UL Listed (File No. E0) BS /. USCG merican Bureau of Shipping (BS) CS Certified (LR ) CFR.0 Type /X Watertight, Corrosion- Resistant Enclosure Fiberglass- Type General Type Motor Voltage Purpose Dusttight Open Type Enclosure Industrial C, 0 Hz DC without Enclosure Surface Mounting Use Enclosure Reinforced Polyester Type & Hazardous Locations Enclosure Class I, Groups C & D Class II, Groups E, F & G Divisions & Type R, & V 00V 0V 0 V 0 V V 0 0V 0 0-OX 0-X 0-JX 0-CX 0-EX 0-HX 0-BOX 0-BX 0-BJX 0-BCX 0-BEX 0-BHX P 0-XOX 0-XX 0-XJX 0-XCX 0-XEX 0-XHX 0 0-OW 0-W 0-JW 0-CW 0-EW 0-HW -/ -/ BOW 0-BW 0-BJW 0-BCW 0-BEW 0-BHW 0 0T-OX 0T-X 0T-BOX 0T-BX P 0T-XOX 0T-XX 0 0T-OW 0T-W -/ -/ 0 0 0T-BOW 0T-BW 0 -/ 0D-OZ 0D-Z 0D-CZ 0D-EZ 0D-HZ -/ 0D-BOZ 0D-BZ 0D-BCZ 0D-BEZ 0D-BHZ 0 -/ 0DT-OZ 0DT-Z -/ 0DT-BOZ 0DT-BZ Bulletin 0RS Manual Reversing Switches 0 0-OW 0-W -/ -/ BOW 0-BW 0 0T-OW 0T-W -/ -/ 0 0 0T-BOW 0T-BW Bulletin 0TS Manual -Speed Switches 0 0-OW 0-W -/ -/ BOW 0-BW 0 0T-OW 0T-W -/ -/ 0 0 0T-BOW 0T-BW Type general purpose flush mounting enclosures with pull box are also available. Order as follows. Change the second letter of the listed cat. no. from to L. Example: 0-LX. For a stainless steel flush plate, change the second letter of the listed cat. no. from to Q. Example: 0-QX. DC manual starters are not UL listed. Fiberglass-reinforced polyester hubs are included with each starter. These enclosures include a cover gasket and drain. It is recommended that a breather also be installed. -0

209 Bulletin 0 Single and Three Phase NEM Manual Starting Switches ccessories Field Installed Factory Installed Pilot Light Kits Kits are available for field installation of pilot lights in Type General Purpose surface or flush mounting enclosures. s standard, a clear pilot light lens is supplied. Pilot lights are not available for Bulletin 0RS or 0TS manual starters. Volts [V] 0 0-N0 0 0-N0 0 0-N N0 Pilot Lights Factory Installed To order, add the following suffix code after the last letter in the listed Example: 0-XD. vailable for Type General Purpose Enclosure only. Volts [V] Suffix Code 0 D 0 0 B 00 C Note: Replacement lamp is NSI part number B (NE-H), 0-N. Fusing The Bulletin 0 is suitable for general installation in accordance with the local Electrical Code. Group Fusing The Bulletin 0 sizes 0 and in Type, X, and enclosures are UL Listed for group fusing with Class J fuses only. See table below for maximum fuse ratings. Maximum Fuse Ratings [] Full Load Current of Smallest Nominal System Voltages Motor mperes [] 0 0V 0 00V

210 Bulletin 0U Manual Starting Switches Overview Toggle Lever Type Switch in Type Enclosure (with Cover Removed) Standards Compliance NEM/EEMC ICS (Industrial Controls and Systems) UL 0 EN0-- BS /. USCG CFR.0 Bulletin 0U Contact position indicator Locking features Wide range of enclosures: Open-type, Type, and Type Undervoltage protection Bulletins 0U and 0TU are the same as the standard Bulletin 0 Manual Starters except for the addition of Undervoltage Protection. These starters provide full line voltage starting, thermal overload protection, as well as Undervoltage Protection. Typical applications are on woodworking machinery, metal sawing machines, and many other machine tools where Undervoltage Protection is needed to meet safety standards. The Undervoltage Protection is accomplished by an electromechanical solenoid which is energized whenever line voltage is present. The solenoid is designed to mechanically open the starter contacts upon power failure, and keep them open even if power is returned to the unit. Only after the starter has been manually reset by pushing the operator to the stop position, can the starter be reenergized. Open Type Bulletin 0U and 0TU switches can replace the Bulletin 0 switches in Types and enclosures of the latest construction without any field modification of the enclosure. Certifications UL Listed (File No. E; Guide No. NLRV) CS Certified (File LR ) merican Bureau of Shipping (BS) Table of Contents Product Overview... this page Product Selection... - ccessories... - Typical Wiring Diagram... - pproximate Dimensions... - CE Marked Hazardous Location: UL Listed (File No. E0) CS Certified (File LR ) 0-0

211 Bulletin 0U Manual Starting Switches Product Selection With Undervoltage Protection Type Of Operator Phase Size Push Button Toggle Lever Ø Ø Ø Ø Maximum Horsepower Rating Motor Voltage C, 0 Hz V 00V 0V 0 Hz Open Type without Enclosure Type General Purpose Enclosure Surface Mounting Type Dusttight, Industrial Use Enclosure Type /X Watertight, Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester Hazardous Locations Enclosure Class I, Groups C & D Class II, Groups E, F & G Divisions & Type & Type R, & 0 0 V V 0 0U-O 0U- 0U-J 0U-C 0U-E 0U-H 0U-BO 0U-B 0U-BJ 0U-BC 0U-BE 0U-BH P 0U-XO 0U-X 0U-XJ 0U-XC 0 0U-O 0U- 0U-J 0U-C 0U-E 0U-H -/ -/ 0 0 0U-BO 0U-B 0U-BJ 0U-BC 0U-BE 0U-BH 0 0TU-O 0TU- 0TU-BO 0TU-B P 0TU-XO 0TU-X 0 0TU-O 0TU- -/ -/ 0 0 0TU-BO 0TU-B Type general purpose flush mounting enclosures with pull box are also available. Order as follows. Change the second letter of the listed cat. no. from to L. Example: 0U-LX. For a stainless steel flush plate, change the second letter of the listed cat. no. from to Q. Example: 0U-QX. Fiberglass-reinforced polyester hubs are included with each starter. These enclosures include a cover gasket and drain. It is recommended that a breather also be installed. Coil Voltage Code for -Phase The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0U-O becomes 0U-OX. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Separate Control [V] Hz XS XP XG 0 Hz XE XD XH XF X 0 Hz XWS XWP XWT 0 Hz XWJ XWD XWH XW XWF Coil Voltage Code for -Phase The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 0U- becomes 0U-. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. Common Control Separate Control [V] Hz P VP VN WL Q WM R 0 Hz H F G N B WC C 0 Hz K S 0 Hz WJ E D WF Breather 0-N (Can be installed at the top of an enclosure.) Drain Only 0-N (Can be installed at the bottom of an enclosure.) Breather-Drain Combination 0-N (Can be installed at the top of an enclosure as a breather or bottom as a drain.) 0 -

212 Bulletin 0U Manual Starting Switches ccessories Field-Installed, Modifications Factory-Installed and Typical Wiring Diagrams With Undervoltage Protection Remote Stop Function remote stop function may be added by removing a short jumper (see typical diagram) and wiring a push button or limit switch in series with the solenoid. fter operation of the emergency stop, the starter must be manually reset. Note: The remote stop terminal block and jumper are not available on devices in the Type and enclosure. Modifications Pilot Light Kits Kits are available for field installation of pilot lights in Type general purpose surface or flush mounting enclosures. clear lens is provided as standard. Pilot lights are not available for Bulletin 0RS or 0TS manual starters. Pilot Lights Factory Installed To order, add the number after the last letter in the listed cat. no. Example: 0U-XD becomes 0U-XD. vailable for Type general purpose enclosure only. Note: Replacement lamp is NSI part number B (NE-H), -B. 0-N. Group Fusing The Bulletin 0U and 0TU Sizes 0 and in Type, /X, and R/ enclosures are UL Listed for group fusing with Class J fuses only. See table below for maximum fuse ratings. Maximum Fuse Ratings [] Full Load Current of Smallest Nominal System Voltages Motor mperes [] 0 0V 0 00V Typical Wiring Diagram (See pplicable Codes and Laws) Volts [V] NEM Type 0 0-N0 0 0-N0 Type 0 0-N N0 0 Remove Jumper to connect remote stop operator wires to vacated terminals. Note: Jumper not available on devices in Type and Enclosure. -

213 Bulletin 0 0U and 0RS 0TS Manual Starting Switches pproximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 0U NEM Type -/ () / () - (0.) -/ () Push Buttons -/ () -/ () / (.) Dia. dditional Mtg. Holes Plaster Wall Mtg. Only / () -/ () () -/ () / / (.) (.) / (0) / () -/ (0) Push Buttons djustable Bracket -/ () -/ () -/ () / / Conduit Knockouts (Top & Bottom) (.) / (.) // (.) (.) -/ (0) / () // (.) / (.) Dia. Mtg. Holes () / (.) / () Conduit Knockouts (Both Sides) -/ (0) Toggle Lever Surface Mounting / (.) / () / (.) (0) Push Buttons -/ () / (.) Mtg. Slots -/ () Knockouts -/ () -/ () -/ () -/ () 0-/ () Plaster Wall -/ (0) -/ () -/ (0) Toggle Lever Flush Mounting for Plaster Wall -/ () Maximum djustment / / (..) Conduit Knockouts (Both Sides) For Bulletin 0 Only Locking ttachment / / (..) Conduit Knockouts (Top & Bottom) / (.) -/ () 0-/ () -/ () Holes #0- Top for Machine Cavity Mounting / (.) Dia. for Plaster Wall Mounting Holes / (.) Dia. -/ () -/ / (.) Mtg. Slots for (0) #0- Screws Toggle Lever Flush Mounting for Machine Cavity / (.) / (.) -/ () Flush Mounting Cavity and Drilling Layout / (.) NEM Type /X -/ (0) -/ () -/ () () -/ () -/ () -/ () -/ () -/ (0) / (.) / () / () -/ () Push Buttons -- () -/ () -/ () -/ () -/ (0) -/ () 0 -/ () Two / (.) Dia. Mtg. Holes -/ () Two / () Conduit hubs Supplied but not Mounted / (.) / (.) Dia. Mtg. / Holes (.) Open Type Without Enclosure (0) Toggle Lever Undervoltage solenoid applies only to Bulletins 0U and 0TU. -

214 Bulletin 0 0U and 0RS 0TS Manual Starting Switches pproximate Dimensions, Continued Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 0 0U, Continued NEM Type R, & NEM Type & -/ () / (.) / (.) -/ (0) -/ () -/ () / () -/ () / (.) -/ (0) -/ () 0-/ () -/ () -/ () -/ () 0-/ () Two (.) Conduit Hubs (Top & Bottom) -/ () Two / () Pipe Tap (Top & Bottom) Two / (.) Mounting Slots NEM Type / () -/ () / () -/ () / () / () -/ () -/ () -/ () / () Mounting Slots (.) Conduit Hubs (Top & Bottom) -/ () -/ () -/ (0) 0-/ (0) () -/ (0) Three / (.) Dia. Mtg. Holes Bulletin 0RS 0TS Open Type Without Enclosure NEM Type -/ () / () -/ () Push Buttons / () -/ (.) / () -/ (0) Push Buttons -/ () -/ () 0 -/ () () -/ () -/ () / / (..) Conduit Knockouts (Both Sides) -/ (.) -/ (.) / -/ (0) (.) Toggle Lever / (.) Dia. Mtg. Holes / () / / (..) Conduit Knockouts (Top & Bottom) -/ () -/ (0) -/ (0) -/ () / () -/ () Toggle Lever -

215 Bulletin NEM Disconnect Switches Product Overview Disconnect Switches Description Bulletin V C F G H Variable depth rod operated Circuit Breaker Mechanisms Variable depth cable operated Fixed depth pre-assembled Safety switch Safety switch Panel Mounting Location Flange mounted Flange mounted Flange mounted Flange-mounted handle Side-mounted handle Switch Ratings Fuse Versions Fusible & non-fusible Fusible & non-fusible Fusible & non-fusible Fusible & non-fusible Fusible & non-fusible Fuse ccommodations Class H, J, and R Class H, J, and R Class H, J, and R Class H, J, and R Class H, J, and R For Use with Enclosure Types /R//X/ /R//X/, R, and R// and /X, R, and Safety Feature Visible Blade Construction 00 k.i.c. With Proper Fusing NFP Compliant Handle lways Linked to the Switch Product Selection Page - Page -0 Page - Page - Page - Bulletin Description Panel Mounting Location Circuit Breaker Frame Size For Use with Circuit Breaker Brands For Use with Enclosure Types Handle always linked to the circuit breaker V Variable Depth Rod Operated Flange mounted up to 00 llen-bradley (0-U) Cutler-Hammer /R//X/ Product Selection Page - 0 -

216 Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Fusible and Non-Fusible Kits 0 Bul. V Disconnect Switch 0 00 (Handle & connecting rod not shown) Bul. V Disconnect Switch 00 (Handle & connecting rod not shown) - Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Industrial rated disconnect switch for use in flange constructed enclosures up to in. deep. pole, 00V C rating 0 00 ratings Can accommodate Class E, H, J, and R fuses vailable in fusible and non-fusible versions Complete kits with accessories ccessories field installed NFP compliant Disconnect switch linked to the handle at all times Visible blade construction for safety Can be used with enclosure Types, R,, X, and Lockable handle in OFF and ON positions Catalog Number Explanation The information below is for reference purposes. Not all combinations will produce a valid Refer to the tables on the following pages for product selection. Code V a Disconnect Switch Description Variable-Depth Flange mounted b Fusing 0 00 Switch with Right-Hand Mechanism Code Description DN Non-fusible DH Class H fuse clips DJ Class J fuse clips DR Class R fuse clips 0 00 Switch with Left-Hand Mechanism Code Description DNX Non-fusible DHX Class H fuse clips DJX Class J fuse clips DRX Class R fuse clips V DR B FF a b c d c Switch and Fuse Rating Non-Fusible Code Description 0 0 switch 0 0 switch switch switch switch switch Fusible 0V; 0 switch, 0 clips 0V; 0 switch, 0 clips 0V; 0 switch, 0 clips 0V; 0 switch, 0 clips 0V; 0 switch, 00 clips 0V; 00 switch, 0 clips 0V; 00 switch, 00 clips 0V; 00 switch, 00 clips 0V; 00 switch, 00 clips 0V; 00 switch, 00 clips 0V; 00 switch, 00 clips 0V; 00 switch, 00 clips 0V; 00 switch, 00 clips 0 0V; 00 switch, 00 clips 0 0V; 00 switch, 00 clips 00V; 0 switch, 0 clips 00V; 0 switch, 0 clips 00V; 0 switch, 0 clips 00V; 0 switch, 0 clips 00V; 0 switch, 00 clips 00V; 00 switch, 0 clips 00V; 00 switch, 00 clips 00V; 00 switch, 00 clips 00V; 00 switch, 00 clips 00V; 00 switch, 00 clips 00V; 00 switch, 00 clips 00V, 00 switch, 00 clips 00V; 00 switch, 00 clips 0 00V; 00 switch, 00 clips 0 00V; 00 switch, 00 clips Code B C D D E F FF G GG H HH Table of Contents Product Selection... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL CS C. No. Certifications culus Listed (File No. E, Guide No. WHTY, WHTY) CE Certified d ccessories (Field Installed) Description Long connecting rod Stainless steel handle Non-metallic handle Standard size line & load lugs Oversized line & load lugs Protective fuse cover () N.O. auxiliary contact () N.O. auxiliary contacts () N.C. auxiliary contact () N.C. auxiliary contacts () N.O. and N.C. electrical interlock () N.O. and N.C. electrical interlock Only available for 0 00 switches (lugs included with 0 switch as standard) Maximum of () auxiliary contacts Only available for 00 & 00 switch 00 switch convertible to left-hand operation in the field

217 Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Fusible and Non-Fusible Disconnect Switch Kits Fusible and Non-Fusible Disconnect Switch Kits Non-fusible disconnect switch kit includes: switch, connecting rod, and metal handle. Fusible disconnect switch kit includes: switch, connecting rod, metal handle, trailer fuse block, and fuse clips. Optional kit accessories listed on the following pages can be added to the disconnect switch kits to create () cat. no. Example: V-DR--B-F. Cont. Current Rating [] 00V C 0V DC UL and CS pplications Maximum HP Complete Disconnect Switch Kits for Type, R,, and Metal Enclosures IEC pplications Maximum kw (C) Switch with Right-Hand Mechanism Switch with Left-Hand Mechanism Fuse Clip Fusible Non-Fusible Fusible Non-Fusible Rating Disconnect Disconnect Disconnect Disconnect -Phase, 0 Hz C -Phase DC -Phase, 0 Hz [] Switch Kit Switch Kit Switch Kit Switch Kit Fuse V 0V 0V 0V V V 0V V 0V 0V 0V 00V 0V 00V Class 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX J V-DJ V-DJX V-DN0 0 H V-DH V-DHX V-DNX0 0 R V-DR V-DRX 0 J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX 0 H V-DH V-DHX R V-DR V-DN0 V-DRX V-DNX0 0 J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX H V-DH V-DHX R V-DR V-DRX J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX 0 H V-DH V-DHX 0 R V-DR V-DRX 0 J V-DJ V-DJX H V-DH V-DN00 V-DHX V-DNX00 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 J V-DJ V-DJX 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX H V-DH V-DN00 V-DHX V-DNX00 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 J V-DJ V-DJX Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. Class J fuses can be installed on Class H fuse clips. However, when selecting a fuse cover (option code E), select the proper clip (Class H, J, or R) in order to receive the correct size fuse cover. Example: V-DH-E becomes V-DJ-E or V-DR-E. 0 -

218 Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Fusible and Non-Fusible Disconnect Switch Kits 0 Cont. Current Rating [] 00V C 0V DC Kit ccessories UL and CS pplications Maximum HP -Phase, 0 Hz Complete Disconnect Switch Kits for Type, R,, and Metal Enclosures C -Phase DC IEC pplications Maximum kw (C) -Phase, 0 Hz Fuse Clip Rating [] Switch with Right-Hand Mechanism Fusible Disconnect Switch Kit Non-Fusible Disconnect Switch Kit Switch with Left-Hand Mechanism Fusible Disconnect Switch Kit Non-Fusible Disconnect Switch Kit Fuse V 0V 0V 0V V V 0V V 0V 0V 0V 00V 0V 00V Class H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX V-DN00 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 H V-DH V-DHX 00 R V-DR V-DRX 00 J V-DJ V-DJX 00 H V-DH0 V-DH0 00 R V-DR0 V-DR0 00 J V-DJ0 V-DJ0 00 H V-DH0 V-DH0 00 R V-DR0 V-DR0 V-DNX00 00 J V-DJ0 V-DJ0 V-DN00 V-DN00 00 H V-DH0 V-DH0 00 R V-DR0 V-DR0 00 J V-DJ0 V-DJ0 00 H V-DH0 V-DH0 00 R V-DR0 V-DR0 00 J V-DJ0 V-DJ0 Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. Class J fuses bolt directly to the switch and trailer fuse block. Class J fuses can be installed on Class H fuse clips. However, when selecting a fuse cover (option code E), select the proper clip (Class H, J, or R) in order to receive the correct size fuse cover. Example: V-DH-E becomes V-DJ-E or V-DR-E. Switch can be converted in the field for left-hand operation. Bulletin V Kit ccessories Field Installed Switch Size Description Suffix Code Longer connecting rod (-/ in.) Disconnect handle Stainless steel B Disconnect handle Non-metallic C Standard size wire connecting lugs Line and load side D Included Oversize wire connecting lugs Line and load side D Protective fuse cover with door E N.O. F uxiliary contact N.O. FF N.C. G N.C. GG Electrical interlock (Early break) N.O. & N.C. N.O. & N.C. H HH Metal disconnect handle provided as standard. For stainless steel handle, select suffix code B. For non-metallic handle, select suffix code C. Select the proper fuse clip (Class J, H, or R) in order to receive the correct size fuse cover. Example: Cat. Nos. V-DH-E, V-DJ-E, or V-DR-E. -

219 Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Disconnect Switch Components Disconnect Switches Continuous Current Rating [] 00V C 0V DC Connecting Rods Dimensions are in inches (millimeters). pproximate dimensions are not intended for manufacturing purposes. Disconnect Switch Size [] 0, 0, 00, 00 00, 00 Operating Handles Handle Type Description Mounting Type, R,, X, Type, R,, Type, X Non-Metallic Painted Metal Stainless Steel NEM, UL, CS Maximum Rating Hp -Phase, 0 Hz Enclosure Depth Minimum Maximum -/ () -/ () V-R -/ () -/ () V-R -/ () 0 () V-RB -/ () () V-RB Enclosure depth is measured from the top of the flange to the disconnect switch mounting surface (mm). Kit includes two connecting rods. Right or Left Flange Right or Left Flange Right or Left Flange Disconnect Switch Size [] C -Phase 0, 0, 00, 00 F-P 0, 0, 00, 00 F-M 00, 00 F-M 0, 0, 00, 00 F-S 00, 00 F-S DC IEC Utilization Category C- Maximum Rating kw -Phase, 0 Hz Switch with Right-Hand Mechanism Switch Only Trailer Fuse Block Kits For Class H, J, or R fuses, select the proper fuse clip kit from the table below. Fuse Clip Kits Includes six clips and mounting hardware Fuse Clip Rating [] Fuse Class 0V 00V For Use With 0 0-N N 0 0-N H N N N N 0 0 C, F, 0-N J G, M, 0-N V Disconnect 0-N Switches 0-N N N 0 0-N R N N N Fuse clips not required: fuse bolts directly to terminal. Included with Bulletin separately mounted fuse blocks. Switch with Left-Hand Mechanism Switch Only 00 0V 0V 0V V V 0 0V 00 00V V-DS0 V-DSX V-DS0 V-DSX V-DS00 V-DSX V-DS00 V-DSX V-DS00 V-DSX V-DS00 V-DS00 lso rated operational current for utilization categories C-0 and C- (IEC 0). Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. Switch can be converted in the field for left-hand operation. Disconnect Switch Size [] 0 V-FS0 0 V-FS0 00 V-FS00 00 V-FS00 00 V-FS Class J fuse -FS Class J fuse V-FSV Class H fuse -N Class R fuse -R When installing 00 Class J fuses, use adapter kit ( 0-N). Separately mounted fuse blocks ( required). 0 -

220 Bulletin C Cable-Operated Disconnect Switches Catalog Number Explanation 0 Bulletin C Cable-Operated Disconnect Switches llen-bradley Bulletin C cable-operated, flange-mounted disconnect switches that meet industrial requirements for dependable disconnecting means ratings vailable with,,,, and 0 ft cable lengths Can accommodate Class E, H, J, and R fuses Precise alignment of the switch with respect to the handle is not required resulting in faster installation Complete kits with accessories ccessories field installed Disconnect switch linked to the handle at all times Visible blade construction for safety Can be used with enclosure Types, R,, X, and Lockable handle in OFF and ON positions Catalog Number Explanation The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. Code C a Disconnect Switch Description Cable operated flange mounted b Fusing 0 00 Switch with Right-Hand Mechanism Code Description DN Non-fusible DH Class H fuse clips DJ Class J fuse clips DR Class R fuse clips 0 00 Switch with Left-Hand Mechanism Code Description DNX Non-fusible DHX Class H fuse clips DJX Class J fuse clips DRX Class R fuse clips C DR B FF a b c d c Switch and Fuse Rating Non-Fusible Code Description 0 0 switch 0 0 switch switch switch switch switch Fusible 0V, 0 switch 0 clips 0V, 0 switch 0 clips 0V, 0 switch 0 clips 0V, 0 switch 0 clips 0V, 0 switch 00 clips 0V, 00 switch 0 clips 0V, 00 switch 00 clips 0V, 00 switch 00 clips 0V, 00 switch 00 clips 0V, 00 switch 00 clips 0V, 00 switch 00 clips 0V, 00 switch 00 clips 0V, 00 switch 00 clips 0 0V, 00 switch 00 clips 0 0V, 00 switch 00 clips 00V, 0 switch 0 clips 00V, 0 switch 0 clips 00V, 0 switch 0 clips 00V, 0 switch 0 clips 0V & 00V, 0 switch 00 clips 0V & 00V, 00 switch 0 clips 0V & 00V, 00 switch 00 clips 0V & 00V, 00 switch 00 clips 0V & 00V, 00 switch 00 clips 0V & 00V, 00 switch 00 clips 0V & 00V, 00 switch 00 clips 0V & 00V, 00 switch 00 clips 0V & 00V, 00 switch 00 clips 0 00V, 00 switch 00 clips 0 00V, 00 switch 00 clips Code 0 B B D D E F FF G GG H HH Table of Contents Product Selection... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL CS C., No. Certifications culus Listed (File No. E, Guide No. WHTY, WHTY) d ccessories (Field Installed) Description ft. cable ft. cable ft. cable ft. cable 0 ft. cable Stainless steel handle Painted metal handle Standard size line & load lugs Oversized line & load lugs Protective fuse cover () N.O. auxiliary contact () N.O. auxiliary contacts () N.C. auxiliary contact () N.C. auxiliary contacts () N.O. and N.C. electrical interlock () N.O. and N.C. electrical interlock Only available with 0 00 switches Only available with switches Maximum of () auxiliary contacts Only available for 00 & 00 switches Only available for 0 00 switches (lugs included on 0 switches as standard) -0

221 Bulletin C Cable-Operated Disconnect Switches Fusible and Non-Fusible Disconnect Switch Kits Fusible and Non-Fusible Disconnect Switch Kits Non-fusible disconnect switch kit includes: switch and non-metallic handle (cable mechanism code must be added to complete the kit). Fusible disconnect switch kit includes: switch, non-metallic handle, trailer fuse block, and fuse clips (cable mechanism code must be added to complete the kit). Optional kit accessories listed on the following pages can be added to the disconnect switch kits to create () cat. no. Example: C-DR--F. Cont. Current Rating [] 00V C 0V DC UL and CS pplications Maximum HP Complete Disconnect Switch Kits for Type, R,, and Metal Enclosures IEC pplications Maximum kw (C) Switch with Right-Hand Mechanism Switch with Left-Hand Mechanism Fuse Clip Fusible Non-Fusible Fusible Non-Fusible Rating Disconnect Disconnect Disconnect Disconnect -Phase, 0 Hz C -Phase DC -Phase, 0 Hz [] Switch Kit Switch Kit Switch Kit Switch Kit Fuse V 0V 0V 0V V V 0V V 0V 0V 0V 00V 0V 00V Class 0 H C-DH C-DHX 0 R C-DR C-DRX 0 J C-DJ C-DJX 0 H C-DH C-DHX 0 R C-DR C-DRX J C-DJ C-DJX C-DN0 0 H C-DH C-DHX C-DNX0 0 R C-DR C-DRX 0 J C-DJ C-DJX 0 H C-DH C-DHX 0 R C-DR C-DRX 0 J C-DJ C-DJX 0 H C-DH C-DHX 0 R C-DR C-DRX 0 J C-DJ C-DJX 0 H C-DH C-DHX 0 R C-DR C-DRX 0 J C-DJ C-DJX 0 H C-DH C-DHX R C-DR C-DN0 C-DRX C-DNX0 0 J C-DJ C-DJX 0 H C-DH C-DHX 0 R C-DR C-DRX 0 J C-DJ C-DJX H C-DH C-DHX R C-DR C-DRX J C-DJ C-DJX 0 H C-DH C-DHX 0 R C-DR C-DRX 0 J C-DJ C-DJX 0 H C-DH V-DHX 0 R C-DR V-DRX 0 J C-DJ C-DJX H C-DH V-DN00 C-DHX V-DNX00 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 H C-DH V-DHX 00 R C-DR V-DRX 00 J C-DJ C-DJX 00 J C-DJ V-DJX 00 H C-DH C-DHX 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 H C-DH C-DHX 00 R C-DR C-DRX 00 J C-DJ C-DJX H C-DH C-DN00 C-DHX C-DNX00 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 H C-DH C-DHX 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 J C-DJ C-DJX The catalog number is incomplete until you select the cable mechanism code from Cable Mechanism Code table. Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC line. Class J fuses can be installed on Class H fuse clips. However, when selecting a fuse cover (option code E), select the proper clip (Class H, J, or R) in order to receive the correct size fuse cover. Example: V-DH-E becomes V-DJ-E or V-DR-E. - 0

222 Bulletin C Cable-Operated Disconnect Switches Fusible and Non-Fusible Disconnect Switch Kits, Continued 0 Cont. Current Rating [] 00V C 0V DC Cable Mechanism Code Select the desired cable length to complete the catalog number. Example: C-DH with a foot cable = C-DH- Kit ccessories Example: C-DH--D-E Basic 0 fusible disconnect switch with foot cable, non-metallic handle, line and load lugs, fuse cover - V UL and CS pplications Maximum HP -Phase, 0 Hz Complete Disconnect Switch Kits for Type, R,, and Metal Enclosures C -Phase DC 00 0V 0V 0V V V 0V V 0V IEC pplications Maximum kw (C) -Phase, 0 Hz 0 0V 0 0V Fuse Clip Rating [] 00 00V 0V 00V Switch with Right-Hand Mechanism Fusible Disconnect Switch Kit 00 H C-DH Non-Fusible Disconnect Switch Kit Switch with Left-Hand Mechanism Fusible Disconnect Switch Kit C-DHX 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 H C-DH C-DHX 00 R C-DR C-DRX Non-Fusible Disconnect Switch Kit Fuse Class 00 J C-DJ C-DJX C-DN00 C-DNX00 00 H C-DH C-DHX 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 H C-DH C-DHX 00 R C-DR C-DRX 00 J C-DJ C-DJX 00 H C-DH0 C-DHX0 00 R C-DR0 C-DRX0 00 J C-DJ0 C-DJX0 00 H C-DH0 C-DHX0 00 R C-DR0 C-DRX0 00 J C-DJ0 C-DJX0 C-DN00 C-DNX00 00 H C-DH0 C-DHX0 00 R C-DR0 C-DRX0 00 J C-DJ0 C-DJX0 00 H C-DH0 C-DHX0 00 R C-DR0 C-DRX0 00 J C-DJ0 C-DJX0 The catalog number is incomplete until you select the cable mechanism code from Cable Mechanism Code table. Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC line. Class J fuses can be installed on Class H fuse clips. However, when selecting a fuse cover (option code E), select the proper clip (Class H, J, or R) in order to receive the correct size fuse cover. Example: V-DH-E becomes V-DJ-E or V-DR-E. Bulletin C Cable Mechanism Code Description Only available with 0 00 switches. Only available with switches. Suffix Code ft cable ft cable ft cable ft cable 0 ft cable 0 Description Bulletin V Kit ccessories Field Installed Suffix Code Switch Size Longer connecting rod (-/ in.) Disconnect handle Stainless steel B Disconnect handle Metal B Standard size wire connecting lugs Line and load side D Included Oversize wire connecting lugs Line and load side D Protective fuse cover with door E uxiliary contact N.O. F N.O. FF N.C. G N.C. GG Electrical interlock N.O. & N.C. H (Early break) N.O. & N.C. HH Non-metallic handle provided as standard. For stainless steel handle, select suffix code B. For metal handle, select suffix code B. Select the proper fuse clip (Class J, H, or R) in order to receive the correct size fuse cover. Example: Cat. Nos. V-DH-E, V-DJ-E, or V-DR-E.

223 Bulletin C Cable-Operated Disconnect Switches Disconnect Switch Components Disconnect Switches Cont. Current Rating [] 00V C 0V DC Cable Mechanisms Operating Handles Handle Type Description Mounting Type, R,, X, Type, R,, Type, X Non-Metallic Painted Metal Stainless Steel NEM, UL, CS Maximum Rating Hp -Phase, 0 Hz Right or Left Flange Right or Left Flange Right or Left Flange Disconnect Switch Size [] C -Phase 0, 0, 00, 00 F-P 0, 0, 00, 00 F-M 00, 00 F-M 0, 0, 00, 00 F-S 00, 00 F-S DC Trailer Fuse Block Kits For Class H, J, or R fuses, select the proper fuse clip kit from the table below. Fuse Clip Kits Includes six clips and mounting hardware Fuse Class H J R IEC Utilization Category C- Maximum Rating kw -Phase, 0 Hz Switch for Right-Hand Mechanism Switch Only Fuse Clip Rating [] 0V 00V For Use With 0 0-N N 0 0-N N N N N 0 0 C, F, 0-N G, M, 0-N V Disconnect 0-N Switches 0-N N N 0 0-N N N N Fuse clips not required: fuse bolts directly to terminal. Included with Bulletin separately mounted fuse blocks. Switch for Left-Hand Mechanism Switch Only 00 0V 0V 0V V V 0 0V 00 00V F-D0 F-DX F-D0 F-DX F-D00 F-DX F-D00 F-DX F-D00 F-DX V-DS00 V-DS00 lso rated operational current for utilization categories C-0 and C- (IEC 0). Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. Switch can be converted in the field for left-hand operation. Disconnect Switch Size [] 0, 0, Cable Length [ft] Right-Hand Cable Mechanisms Left-Hand Cable Mechanisms C-CM C-CMX C-CM C-CMX C-CM C-CMX 0 C-CM C-CMX C-CM C-CMX C-CM C-CMX C-CM C-CMX 0 C-CM C-CMX C-CM C-CMX C-CM0 C-CMX0 C-CM C-CMX 0 C-CM C-CMX C-CM C-CMX C-CM C-CMX C-CM C-CMX 0 C-CM C-CMX Disconnect Switch Size [] 0 V-FS0 0 V-FS0 00 V-FS00 00 V-FS00 00 V-FS Class J fuse -FS Class J fuse V-FSV Class H fuse -N Class R fuse -R When installing 00 Class J fuses, use adapter kit ( 0-N). Fuse clips not required. Separately mounted fuse blocks ( required). 0 -

224 Bulletin F Fixed-Depth Flange-Mounted Disconnect Switches Fusible and Non-Fusible Type 0 F-NF0 Disconnect Switch and Operating Mechanism Bulletin F Fixed-Depth Flange-Mounted Disconnect Switches Industrial rated disconnect switch pre-assembled on a mounting bracket for use in flange constructed enclosures. -pole, 00V C rating 0, 0, 00, and 00 ratings Can accommodate Class E, H, J, and R fuses vailable in a non-fusible version ccessories field installed Disconnect switch linked to the handle at all times Visible blade construction for safety vailable in left-hand or right-hand flange operation Can be used with enclosure Types, Lockable handle Fusible and Non-Fusible Disconnect Switch Kits Non-fusible disconnect switch includes: switch, operating mechanism and handle. Fusible disconnect switch includes: switch, operating mechanism and handle (select the proper fuse block adapter plate with fuse clips from the table below. Line and load lugs located in the ccessories section on page -. Continuous Current Rating [] 00V C 0V DC UL and CS pplications Maximum Hp Fuse Block dapter Plate with Fuse Clips Disconnect Switches for Type and Type Enclosures DC IEC pplications Maximum kw (C) Fusible Open Type without Enclosure Flange Construction Non-Fusible Open Type without Enclosure Flange Construction -Phase, 0 Hz C -Phase -Phase, 0 Hz Right Hand Left Hand Right Hand Left Hand 00 0V 0V 0V V V 0V 0V 0 0V 0 0V Table of Contents ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL CS C., No. Certifications UL Listed (File No. E, Guide No. WHTY) CS Certified (File No. LR) CE Certified 00 00V F-NF0 F-NFL0 F-N0 F-NL F-NF0 F-NFL0 F-N0 F-NL F-NF00 F-NFL00 F-N00 F-NL F-NF00 F-NFL00 F-N00 F-NL00 Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. Disconnect Size [] Class R Class J Class H Class H and E Fuse Clip 0V 00V 00V 0V 00V Rating [] 0 F-R F-R F-J F-C F-C 0 F-R F-R F-J F-C F-C 0 F-R F-C 0 F-R F-R F-J F-C F-C 00 F-R F-R F-J F-C F-C 00 F-R F-R F-J F-C F-C 00 F-R F-R F-J F-C F-C F-R F-R F-J F-C F-C -

225 Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Circuit Breaker Kits V-C0 Circuit Breaker Kit (Shown without handle and connecting rod) Circuit Breaker Kits Circuit Breaker Kits include: Connecting rod Metal handle Bulletin V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Circuit breaker operating mechanisms for use with llen-bradley and Cutler-Hammer circuit breakers in enclosures up to in. deep. -pole, 00V C rating 0, 0, and 00 circuit breaker frame sizes Complete kits with accessories ccessories Field installed Can be used with enclosure Types, R,, X, and Can be field installed on a right-flanged or left-flanged enclosure Lockable handle Circuit breaker operating mechanism (circuit breaker to be supplied by customer) Table of Contents ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications UL Recognized (File No. E, Guide No. NLDX) CS Certified (File No. LR) Optional accessories listed below can be added to the circuit breaker kits to create () cat. no. Example: V-C0--B-F Kit ccessories -Pole Circuit Breaker Operating Mechanism Brand Frame Size [] Frame Designation llen-bradley Cutler-Hammer llen-bradley Cutler-Hammer llen-bradley Cutler-Hammer U-H (MCCB), 0M-H (MCP) EG, HMCPE 0M-I (MPCB + MCP) EHD, FD, FDB, FDC, HFD, HMCP 0U-J (MCCB), 0M-J (MPCB + MCP) JG V-C V-C0 V-C Cutler-Hammer 0 JD, JDB, JDC, HJD, HMCP V-C0 llen-bradley Cutler-Hammer U-K (MCCB), 0M-K (MPCB + MCP) KD, KDB, KDC, HKD, HMCP V-C00 Bulletin V Kit ccessories Field Installed Circuit Breaker Frame Size [] Description Suffix Code Longer Connecting Rod (-/ -/ in.) Disconnect Handle Stainless Steel B Disconnect Handle Non-Metallic C N.O. F uxiliary Contact includes adapter kit N.O. FF N.C. G N.C. GG Metal handle provided as standard. For stainless steel handle, select suffix code B. For non-metallic handle, select suffix code C. 0 -

226 Bulletin V Variable-Depth Flange-Mounted Disconnect Switches Circuit Breaker Components Components Circuit Breaker Operating Mechanism The mechanism listed must be combined with a connecting rod, operating handle, and a circuit breaker (supplied by customer) to obtain a functional device. Connecting Rods pproximate dimensions are in inches (millimeters). pproximate dimensions are not intended for manufacturing purposes. Circuit Breaker Frame Size [], 0, 0, 00 Operating Handle -Pole Circuit Breaker Operating Mechanism Brand Frame Size [] Frame Designation llen-bradley Cutler-Hammer llen-bradley Cutler-Hammer llen-bradley Cutler-Hammer U-H (MCCB), 0M-H (MCP) EG, HMCPE 0M-I (MPCB + MCP) EHD, FD, FDB, FDC, HFD, HMCP 0U-J (MCCB), 0M-J (MPCB + MCP) JG V-M V-M0 V-M Cutler-Hammer 0 JD, JDB, JDC, HJD, HMCP V-M0 llen-bradley Cutler-Hammer Circuit breakers to be provided by customer U-K (MCCB), 0M-K (MPCB + MCP) KD, KDB, KDC, HKD, HMCP V-M0 Enclosure Depth Minimum Maximum -/ () -/ () V-R -/ () -/ () V-R Handle Type Description Mounting Circuit Breaker Frame Size [] Operating Handle Type, R,, X, Non-Metallic Right or Left Flange, 0, 0, 00 F-P Type, R,, Painted Metal Right or Left Flange, 0, 0, 00 F-M Type, X Stainless Steel Right or Left Flange, 0, 0, 00 F-S 0 -

227 Bulletin D Fixed-Depth Flange-Mounted Circuit Breaker Operating Mechanism Product Selection D-N and D-N0 (Circuit Breaker Not Included. uxiliary Contact and dapter Kit Must be Ordered Separately) Bulletin D Fixed-Depth Flange-Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled on a mounting bracket for use in flange constructed enclosures. Circuit breaker operating mechanisms for use with Cutler-Hammer circuit breakers in a fixed depth enclosure. -pole, 00V C rating 0 00 frame sizes ccessories Field installed Can be used with enclosure Types, Lockable handle vailable in right-hand or left-hand flange operation Table of Contents ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications UL Recognized (File No. E, Guide No. NLDX) CS Certified (File No. LR) Circuit Breaker Operating Mechanism The device is complete, and includes a handle, operating mechanism, and slide/bail mechanism all pre-assembled on a mounting bracket. Brand Cutler-Hammer Circuit breakers to be provided by customer. -Pole Circuit Breaker Operator Slide or Bail Frame Size [] Frame Designation 0 EHD, FD, FDB, FDC, HFD, HMCP D-N D-N0 0 JD, JDB, JDC, HJD, HMCP D-N0 D-N 00 KD, KDB, KDC, HKD, HMCP D-N0 00 LD, HLD, LDC, L, HL, LC, HLC D-N 00 M, MDL, HMDL, HM, MC, ND, HND, NDC D-N D-N 00 NB Tri-Pac D-NT 00 ND, HND, NDC, NB, HNB, NC, HNC D-N 0 -

228 Bulletin V Variable-Depth Flange-Mounted Operating Mechanisms Remote or Dual Type Remote Drive Operating Mechanism Main Drive Dual Operating Mechanism (Includes Operating Handle) Bulletin V Variable-Depth Flange-Mounted Operating Mechanisms Operating mechanism for remote or dual operation of disconnect switches or circuit breakers. Remote: 0 00 disconnect switches Fusible or non-fusible Remote: 0 00 frame circuit breakers Dual: 0 00 disconnect switches Dual: 0 frame circuit breaker Can be used with enclosure Types, R,, Lockable handle Table of Contents ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications UL Recognized (File No. E, Guide No. NLDX) CS Certified (File No. LR) 0 Description Remote Operating Mechansims llows the handle to be mounted above or below the disconnect switch or circuit breaker. Dual Operating Mechanisms Permits the control of () disconnect switches or circuit breakers utilizing a common handle. Operation Both the remote and dual operating mechanisms consist of () components: a main drive mechanism (which includes the handle) and a remote drive mechanism. To obtain a functional device, these components must be properly combined with a connecting link (supplied by the customer), disconnecting means and connecting rod. Προδυχτ Σελεχτιον Remote or Dual Operated Mechanisms Separate Components Type of Mechanism Remote Dual Enclosure Type Type, R, Type Type, R, Type Size [] Disconnect Switch Circuit Breaker Frame Designation Brand Mounting 0, 0, 00, 00 Right V-H Left V-HL 00, 00 Right V-H Left V-HL EHD, FD, FDB, FDC, Right V-H0 0, 0, 00 HFD, HMCP, JD, JDB, Cutler-Hammer JDC, HJD, KD, KDB, Left V-HL0 KDC, HKD 0, 0, 00, 00 Right V-W Left V-WL 00, 00 Right V-W Left V-WL EHD, FD, FDB, FDC, Right V-W0 0, 0, 00 HFD, HMCP, JD, JDB, Cutler-Hammer JDC, HJD, KD, KDB, Left V-WL0 KDC, HKD () 0, () 0, () 00, Right V-H0 or any combination of () 0 00 Switches Left V-HL0 Two 0 EHD, FD, FDB, FDC, Right V-H Cutler-Hammer HFD, HMCP Left V-HL () 0, () 0, () 00, Right V-W0 or any combination of () 0 00 Switches Left V-WL0 Two 0 EHD, FD, FDB, FDC, Right V-W Cutler-Hammer HFD, HMCP Left V-WL Includes main and remote drive mechanisms. Does not include rectangular bar stock / x / in. (. x. mm) connecting bar between disconnecting means and connecting rod, to be supplied by user. -

229 Bulletin M Fixed-Depth Flange-Mounted Operating Mechanisms Overview/Product Selection Right-Hand Flange-Mounted, Remote Operated, Non-Fusible Disconnect Switch, and Operating Mechanism Bulletin M Fixed-Depth Flange-Mounted Operating Mechanisms Operating mechanism for remote operation of a disconnect switch: Remote: 0 00 disconnect switch Fusible or non-fusible Can be used with enclosure Type and vailable in left-hand or right-hand flange operation Lockable handle Table of Contents ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications UL Recognized (File No. E, Guide No. NLDX) CS Certified (File No. LR) Description Operation The remote mechanism consists of () components a disconnect switch and the operating mechanism. To obtain a functional device, these components must be properly combined with a connecting link (supplied by the customer). This method allows the user to determine specific distances required between the disconnect switch and the operating mechanism. Note: The operating mechanism can only be mounted below the switch. Product Selection Fusible and Non-Fusible Disconnect Kits Non-fusible disconnect switch includes: switch, operating mechanism and handle. Fusible disconnect switch includes: switch, operating mechanism and handle (select the proper fuse block adapter plate with fuse clips from the table below). Line and load lugs located in the ccessories, see -. Continuous Current Rating [] 00V C 0V DC UL and CS pplications Maximum Hp Fuse Block dapter Plate Kits with Fuse Clips Complete Disconnect Switch Kit for Type and Type IEC pplications Maximum kw (C) Open Type without Enclosure Flange Construction Fusible Non-Fusible -Phase, 0 Hz C -Phase DC -Phase, 0 Hz Right Hand Left Hand Right Hand Left Hand 00 0V 0V 0V V V 0V V 0V 0 0V 0 0V 00 00V M-NF0 M-NFL0 M-N0 M-NL M-NF0 M-NFL0 M-N0 M-NL M-NF00 M-NFL00 M-N00 M-NL M-NF00 M-NFL00 M-N00 M-NL00 Does not include rectangular bar stock / x / in. (. x. mm) connecting bar between switch and remote operating mechanism and handle to be provided by user. Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. Disconnect Size [] Class R Class J Class H Fuse Clip 0V 00V 00V 0V 00V Rating [] 0 F-R F-R F-J F-C F-C 0 F-R F-R F-J F-C F-C F-R F-C 0 F-R F-R F-J F-C F-C 00 F-R F-R F-J F-C F-C 00 F-R F-R F-J F-C F-C 00 F-R F-R F-J F-C F-C F-R F-R F-J F-C F-C 0 -

230 Bulletin G/GX/GY Safety Switches Fusible and Non-Fusible Kits Catalog Number Explanation G B F J 0W a b c d e f g Code G GY GX Code a Bulletin Number b Switch Ratings [] Description B 0 C 0 Description Enclosed disconnect safety switch in standard-size enclosure (0 00 ) Enclosed disconnect safety switch in large-size enclosure (0 00 ) Enclosed disconnect safety switch in extra large-size enclosure (0 00 ) D 00 E 00 F 00 G 00 Code F C S K Code c Enclosure Type Description Type R//: Rainproof, watertight, dusttight, painted metal enclosure with screw fasteners and non-metallic handle Type /X: Watertight, corrosion-resistant, stainless steel enclosure with screw fasteners and non-metallic handle Type /X: Watertight, corrosion-resistant, non-metallic enclosure with screw fasteners and non-metallic handle Type : Hazardous location (Class II, Division, Group F+G and Class III Division and ) painted metal enclosure with screw fasteners and non-metallic handle Specify lens color by adding one of the following letters: R = Red, = mber, B = Blue, G = Green. pole enclosed switches can accomodate () pilot device, pole enclosed switches can accomodate () pilot devices. Maximum of () auxiliary contacts. d Poles Description -pole, -phase -pole, -phase -pole, -phase Code N H J R e Fusing Description Non-fusible Class H fuse clips Class J fuse clips Class R fuse clips Code Blank f Fuse Voltage Description Non-fusible 0V C/0V DC 00V C/00V DC Code S SB g Options (Factory Installed) Description Momentary push button (Flange-mounted) Momentary push button (Bottom-mounted) -position selector switch E EI S -position selector switch -position selector switch (Illuminated) -position selector switch (Spring return) Pilot light Push-to-test pilot light N.O. auxiliary - disconnect N.C. auxiliary - disconnect 0W Viewing window Painted metal handle Stainless steel handle Protective fuse cover 0 N.O. and N.C. interlock N.O. and N.C. interlocks 0-0

231 Bulletin G/GX/GY Safety Switches Fusible Type G-BFH Enclosed Disconnect Switch Bulletin G/GX/GY 0 00 switch ratings 0V: -pole, φ and -pole, φ Versions Can accommodate Class H, R, and J fuses Type R// (painted metal), Type /X (stainless steel), and Type /X (non-metallic) enclosures 0 00 switch ratings in extra-capacity enclosures 0 00 switch ratings for -pole, -phase applications Disconnect switch linked to the handle at all times Visible blade construction for safety Non-metallic handle standard (0 00 ) Metal or stainless steel handle optional Lockable handle Options factory installed ccessories field installed Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. WIX) 0 0V, Fusible with Class H Fuse Clips, (-pole, -phase/-pole, -phase), standard size enclosure Continuous Current Horsepower Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic Rating 0V C, 0V C, -Pole, -Pole, -Pole, -Pole, -Pole, -Pole, [] -Phase -Phase -Phase -Phase -Phase -Phase -Phase -Phase 00V C 0V 0V DC Std. Max. Std. Max. DC 0.. G-BFH G-BFH G-BCH G-BCH G-BSH G-BSH G-CFH G-CFH G-CCH G-CCH G-CSH G-CSH G-DFH G-DFH G-DCH G-DCH G-DSH G-DSH G-EFH G-EFH G-ECH G-ECH G-FFH G-FCH G-GFH G-GCH 0V, Fusible with Class H Fuse Clips, (-pole, -phase/-pole, -phase), extra large size enclosure Continuous Current Horsepower Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic Rating 0V C, 0V C, -Pole, -Pole, -Pole, -Pole, -Pole, -Pole, [] -Phase -Phase -Phase -Phase -Phase -Phase -Phase -Phase 00V C 0V 0V DC Std. Max. Std. Max. DC 0.. GX-BFH GX-BFH GX-BCH GX-BCH GX-BSH GX-BSH GX-CFH GX-CFH GX-CCH GX-CCH GX-CSH GX-CSH GX-DFH GX-DFH GX-DCH GX-DCH 0V, Fusible with Class H Fuse Clips, (-pole, -phase/-pole, -phase), large size enclosure Continuous Current Horsepower Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic Rating 0V C, 0V C, -Pole, -Pole, -Pole, -Pole, -Pole, -Pole, [] -Phase -Phase -Phase -Phase -Phase -Phase -Phase -Phase 00V C 0V 0V DC Std. Max. Std. Max. DC 0.. GY-BFH GY-BFH GY-BCH GY-BCH GY-CFH GY-CFH GY-CCH GY-CCH GY-DFH GY-DFH GY-EFH GY-EFH 0V, Fusible with Class H Fuse Clips, (-pole, φ), standard size enclosure Horsepower Type R// Painted Metal Type /X Stainless Steel Continuous Current Rating [] 00V C 0V C, -Phase -pole, -Phase -pole, -Phase 0V DC Std. Max. 0. G-BFH G-BCH 0. G-CFH G-CCH 00 0 G-DFH G-DCH Class R and J fuse clips can be supplied as a factory option in place of Class H clips. To order Class R fuse clips, replace H from the cat. no. with R. Example: G-BFH becomes G-BFR. To order Class J fuse clips, replace H from the cat. no. with J. Example: G-BFH becomes G-BFJ. The same applies to Bul. GX and GY. Type hazardous location enclosure (Class II, Division, Group F+G and Class III, Divisions and ) can be supplied by replacing the F in the listed cat. no. with the letter K. Example: G-BKH. 0 -

232 Bulletin G/GX/GY Safety Switches Fusible Type G-BFJ Enclosed Disconnect Switch Bulletin G/GX/GY 0 00 switch ratings 00V: -pole, -phase and -pole, -phase versions Can accommodate Class H, R, and J fuses Type R// (painted metal), Type /X (stainless steel), and Type /X (non-metallic) enclosures 0 00 switch ratings in extra-capacity enclosures 0 00 switch ratings for -pole -phase applications Disconnect switch linked to the handle at all times Visible blade construction for safety Non-metallic handle standard (0 00 ) Metal or stainless steel handle optional Lockable handle Options factory installed ccessories field installed Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. WIX) 0 00V, Fusible with Class H Fuse Clips, (-pole, -phase), standard size enclosure Continuous Current Rating [] 00V C 0V DC Type R// Painted Metal 00V, Fusible with Class H Fuse Clips, (-pole, -phase), extra large size enclosure 00V, Fusible with Class H Fuse Clips, (-pole, -phase), large size enclosure 00V, Fusible with Class H Fuse Clips, (-pole, -phase), standard size enclosure Type /X Stainless Steel Type /X Non-metallic Horsepower 0V C 00V C 0V -Pole, -Phase -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC 0. 0 G-BFH G-BCH G-BSH G-CFH G-CCH G-CSH G-DFH G-DCH G-DSH G-EFH G-ECH G-FFH G-FCH G-GFH G-GCH Continuous Current Rating [] 00V C 0V DC Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic Horsepower 0V C 00V C 0V -Pole, -Phase -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC 0. 0 GX-BFH GX-BCH GX-BSH GX-CFH GX-CCH GX-CSH GX-DFH GX-DCH Continuous Current Rating [] 00V C 0V DC Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic Horsepower 0V C 00V C 0V -Pole, -Phase -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC 0. 0 GY-BFH GY-BCH GY-CFH GY-CCH GY-DFH GY-EFH Continuous Current Rating [] 00V C 0V DC Horsepower Type R// Painted Metal -Pole, -Phase Type /X Stainless Steel -Pole, -Phase 0V C 00V C 0V Std. Max. Std. Max. DC 0. 0 G-BFJ G-BCJ G-CFJ G-CCJ G-DFJ G-DCJ Class R and J fuse clips can be supplied as a factory option in place of Class H clips. To order Class R fuse clips, replace H from the cat. no. with R. Example: G-BFH becomes G-BFR. To order Class J fuse clips, replace H from the cat. no. with J. Example: G-BFH becomes G-BFJ. The same applies to Bul. GX and GY. Type hazardous location enclosure (Class II, Division, Group F+G and Class III, Divisions and ) can be supplied by replacing the F in the listed cat. no. with the letter K. Example: G-BKH. -

233 Bulletin G/GX/GY Safety Switches Non-Fusible Type GX-BFN Enclosed Disconnect Switch 00V, Non-Fusible, (-pole, φ), standard size enclosure Bulletin G/GXGY 0 00 switch ratings 00V: -pole, -phase and -pole, -phase versions Non-fusible versions only Type R// (painted metal), Type /X (stainless steel), and Type /X (non-metallic) enclosures 0 00 switch ratings in extra-capacity enclosures 0 00 switch ratings for -pole -phase applications Disconnect switch linked to the handle at all times Visible blade construction for safety Non-metallic handle standard (0 00 ) Metal or stainless steel handle optional Lockable handle Options factory installed ccessories field installed 00V, Non-Fusible, (-pole, -phase), standard size enclosure Continuous Current Rating [] 00V C 0V DC Horsepower 00V, Non-Fusible, (-pole, -phase), extra large size enclosure 00V, Non-Fusible, (-pole, -phase), large size enclosure Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic 0V C 00V C 0V -Pole, -Phase -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC G-BFN G-BCN G-BSN G-CFN G-CCN G-CSN G-DFN G-DCN G-DSN G-EFN G-ECN G-FFN G-FCN G-GFN G-GCN Continuous Current Rating [] 00V C 0V DC Horsepower Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic 0V C 00V C 0V -Pole, -Phase -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC GX-BFN GX-BCN GX-BSN GX-CFN GX-CCN GX-CSN GX-DFN GX-DCN Continuous Current Rating [] 00V C 0V DC Horsepower Type R// Painted Metal Type /X Stainless Steel Type /X Non-metallic 0V C 00V C 0V -Pole, -Phase -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC GY-BFN GY-BCN GY-CFN GY-CCN GY-DFN G-EFN Continuous Current Rating [] 00V C 0V DC Horsepower Type R// Painted Metal Table of Contents Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. WIX) Type /X Stainless Steel 0V C 00V C 0V -Pole, -Phase -Pole, -Phase Std. Max. Std. Max. DC 0. 0 G-BFN G-BCN G-CFN G-CCN G-DFN G-DCN Type hazardous location enclosure (Class II, Division, Group F+G and Class III, Divisions and ) can be supplied by replacing the F in the listed cat. no. with the letter K. Example: G-BKN. 0 -

234 Bulletin G/GX/GY Safety Switches Modifications Bulletin G/GXGY Modifications Factory-Installed Description Enclosure Type Suffix Code Switch Rating [] Momentary Push Button ( N.O.) (located on enclosure flange) R// painted metal, /X stainless steel -S Momentary Push Button (located on bottom of enclosure) R// painted metal, /X stainless steel -SB HND-OFF-UTO Selector Switch R// painted metal, /X stainless steel - -position Selector Switch R// painted metal, /X stainless steel -S -position Selector Switch R// painted metal, /X stainless steel -E -position Illuminated Selector Switch R// painted metal, /X stainless steel -EI Pilot Light R// painted metal, /X stainless steel - Push-to-test Pilot Light R// painted metal, /X stainless steel - uxiliary Contact ( N.O.) uxiliary Contact ( N.C.) R// painted metal, /X stainless steel, /X non-metallic R// painted metal, /X stainless steel, /X non-metallic - - Enclosure Door Viewing Window R// painted metal, /X stainless steel -0W Painted Metal Handle R// painted metal - S S Stainless Steel Handle /X stainless steel - S S Protective Fuse Cover with Door R// painted metal, /X stainless steel - Electrical Interlock - Early Break ( N.O. and N.C.) R// painted metal, /X stainless steel -0 Electrical Interlock - Early Break ( N.O. and N.C.) R// painted metal, /X stainless steel - = vailable Option S = Standard Specify lens color by adding one of the following letters: R = Red, G = Green, = mber, B = Blue pole enclosed switches can accomodate () pilot device, pole enclosed switches can accomodate () pilot devices. Maximum of () auxiliary contacts. Non-metallic handle provided as standard (0 00 ). For painted metal handle, select suffix code -. For stainless steel handle, select suffix code

235 Bulletin G Safety Switches Hazardous Locations Overview/Product Selection Bulletin G Safety Switch Hazardous Locations 00 switch rating for use in 0, 0, and 00 applications Type R, & bolted enclosure with breather and drain For use in Class I, Div. &, Groups C & D hazardous gas or vapor locations Non-fusible version only Viewing window provided as standard to readily see the blades of the disconnect switch uxiliary contact provided as standard Lockable handle Provisions for a mechanical key interlock switch (trapped key, kirk key, etc.) Hinged cover for easy access Table of Contents Product Selection... this page pproximate Dimensions... this page Standards Compliance UL 0 CS C., No. and 0 Certifications culus Listed (File No. E, Guide No. WPRP) Product Selection Size [] 0V C Horsepower 00V C Type R, & Bolted Enclosure Class I, Div. &, Groups C & D Std. Max. Std. Max. 0V C pproximate Dimensions G-NX 0 -

236 Bulletin H Safety Switches Fusible and Non-Fusible Type Bulletin H Safety Switches 0 00 switch ratings Type, R, or (painted metal) enclosures 00V: Non-fusible 0V: -phase, fusible 00V: -phase, fusible Visible blade construction for safety Side-mounted metal handle Lockable handle Can accomodate Class H, R, and J fuses ccessories field installed Table of Contents Product Selection... this page ccessories... - Standards Compliance UL CS C., No. Certifications UL Listed (File No. E, Guide No. WIX) CS Certified (File No. LR) Non-Fusible Disconnect Switch (00V C) 0 Continuous Current Rating [] Fusible Disconnect Switch (0V C) Fusible Disconnect Switch (00V C) UL & CS pplication Horsepower (Maximum) -Phase (0 Hz) -Phase (0 Hz) Type Type R Type 0V C 0V C 0V C 00V C V DC 0V DC H-BN H-BNN H-BFN H-CN H-CNN H-CFN H-DN H-DNN H-DFN H-EN H-ENN H-EFN UL & CS pplication Horsepower -Phase (0 Hz) -Phase (0 Hz) Type Type R Type Continuous V DC 0V DC 0V C 0V C Current Std. & Std. & Rating [] Std. Max. Std. Max. 0V C 00V C Max. Max. 0.. H-BH H-BNH H-BFH H-CH H-CNH H-CFH H-DH H-DNH H-DFH H-EH H-ENH H-EFH Includes a neutral lug for four wire applications. Continuous Current Rating [] UL & CS pplication Horsepower -Phase (0 Hz) -Phase (0 Hz) 0V C 0V C 0V C 00V C Std. Max. Std. Max. V DC Std. & Max. 0V DC Std. & Max. Type Type R Type H-BH H-BNH H-BFH H-CH H-CNH H-CFH 00 0 H-DH H-DNH H-DFH 00 0 H-EH H-ENH H-EFH -

237 - -B uxiliary Contacts uxiliary Contacts Bulletin NEM Disconnect Switches ccessories Description For Use With N.O. Contact C, F, V, and M (0 00 ), G (0 00 ) Disconnect Switches -N N.C. Contact D, V ( 00 -N Frame) Circuit Breakers N.O. Contact - N.C. Contact C, G, and V -B Disconnect Switches 00 -N -N -N -N -N -N uxiliary Contact dapter Kit For Disconnect Switches uxiliary Contact dapter Kit For Disconnect Switches with Left-Hand Mechanism uxiliary Contact dapter Kit For Disconnect Switches with Left-Hand Mechanism uxiliary Contact dapter Kit For Circuit Breakers Electrical Interlocks Electrical Interlock dapter Kit Requires an adapter kit on new installations. One adapter kit enables up to two auxiliary contacts to be installed. dditional adapter kit ( -N) required for installation on 00 switch. 00 only -N 0 00 Disconnect Switch 00 Disconnect Switch and 0 Frame llen- Bradley, Cutler-Hammer 0, 00 Frame llen- Bradley, Cutler-Hammer 0 Frame llen-bradley, Cutler-Hammer 00 Frame llen-bradley, Cutler-Hammer 00, 00, 00 Frame Cutler-Hammer V Disconnect Switch with Left-Hand Mechanism, 0 00 V Disconnect Switch with Left-Hand Mechanism, D, V Circuit Breakers -N -N -N V Circuit Breaker -N D Circuit Breaker -N D Circuit Breaker -N D Circuit Breaker -N N.O. and N.C. early break C, G & V -N N.O. and N.C. early break Disconnect Switches with Left-/Right-Hand Mechanism, -N 0 00 & 00 N.O. and N.C. early break C & V -N N.O. and N.C. early break Disconnect Switch with Right-Hand Mechanism, -N 00, 00 N.O. and N.C. early break N.O. and N.C. early break C and V Disconnect Switch with Left-Hand Mechanism, N -N N.O. and N.C. early break V Disconnect Switch -N N.O. and N.C. early break with Left-Hand Mechanism, 00 -N0 N.O. and N.C. early break V Disconnect Switch -N N.O. and N.C. early break with Left-Hand Mechanism, 00 -N 0 DPDT (for 0, Type & R only) -N DPDT (for 0, Type ) DPDT (for 0, Type, R, and ) H Safety Switch DPDT (for 00, Type, -N R, and ) DPDT (for 00, Type, R, and ) 00 Disconnect Switch G Disconnect Switch -N - 0

238 Bulletin NEM Disconnect Switches ccessories, Continued 0 R-N Lug Connectors ( per package) Disconnect Size [] Description For Use With Wire Size 0 # WG Wire 0 # WG Wire R-N 00 # /0 WG Wire C, F, G, and R-N # /0 WG Wire V Disconnect Switches R-N 00 # 0 MCM Wire (oversized) -LF Ground Connectors Ground Lug Kits () of #/0 0 MCM Wire R-N # 00 MCM Wire (oversized) R-N () of #/0 0 MCM Wire R-N0 () of #/0 0 MCM Wire -N or -R 00 fuse blocks R-N 0 00 C, F, G, and -GR V Disconnect Switches -GR 00 -GR 0, 0 -GR H Safety Switches -GR 00, 00 -GR Neutral Kits 0/00V C Fusible (Type & R) -NK 0/00V C Non-Fusible (Type & R) -NK 0/00V C Fusible & Non-Fusible (Type ) -NK 0/00V C Fusible & Non-Fusible (Type & R) -NK 0/00V C Fusible (Type ) -NK 0/00V C Non-Fusible (Type ) H Safety Switches -NK 0/00V C Fusible (Type & R) -NK 0/00V C Non-Fusible (Type, R, and ) -NK 0/00V C Fusible (Type ) -NK 0/00V C Fusible & Non-Fusible (Type & R) -NK0 0/00V C Fusible & Non-Fusible (Type ) -NK Fuse Clips ( per package) Fuse Clip Rating [] Fuse Class 0V 00V 0-N N H 0 0-N N C, F, G, and 0-N V Disconnect Switches 0-N J Fuse Blocks 0 0-N N R 0 0-N N N N H, R Class R Fuse Clip Kits 0V C (Type, R, ) 0-N0 00V C (Type, R) 0-N 00V C (Type ) 0-N 0V C (Type, R, ) H Safety Switches 0-N 00V C (Type, R, and ) 0-N 0/00V C (Type & R) 0-N 0/00V C (Type ) 0-N 0/00V C (Type, R, and ) 0-N ll terminals of the 0 switches are furnished with self-lifting pressure plate connectors as standard. Fuse clips not required; fuse bolts directly to terminal. Included with Bulletin separate mounted fuse blocks. Each kit contains () lugs. Each kits contains () lugs. -

239 Bulletin NEM Disconnect Switches ccessories, Continued Protective Fuse Covers (for use with Bul. C, G, and V disconnect switches) Switch Rating [] Fuse Class Non-Fusible H, R H, R J J Non-Fusible Non-Fusible 0V Fuse Clip Rating [] 00V H, R 0 H, R 0 J N -N 00 H, R N Switch with right-hand mechanism. Switch with left-hand mechanism. Non-Fusible H, J, R Non-Fusible H, J, R Non-Fusible H, J, R Non-Fusible H, J, R Non-Fusible J N -N -N -N -N Protective Line Covers (for use with Bul. C, G, and V disconnect switches) N0 00 -N 00 -N 00 -N 0 -

240 Bulletin NEM Disconnect Switches ccessories, Continued Description For Use With Defeater Bracket Extension Kit For use with operating handles that do not align properly with the door catch or door hardware on enclosures with a rolled lip flange construction. lternate Mounting Kits For use where the flange material thickness is greater than / in. (. mm). ll F and V Handles (except V-R and V-R) For switches, defeater bracket is included with connecting rod kits. Operating Handles V-H or V-H Operating Handles V-H V-H V-H V-H Channel Support Kits For use to prevent flexing of the operating handle mounting surface. This is especially useful when the operating handle is mounted on a channel in a multi-door enclosure Switches pplies only to Operating Handle Cat. Nos. V-P, M, and S. V-H 0 Packaged in quantities of 0. Conduit Hubs (for Type R enclosures) / in. hub -N in. hub -N -/ in. hub H Safety Switches -N -/ in. hub -N in. hub -N -/ in. hub -N Conduit Connectors Metallic Conduit Connectors in. (. mm) 0 -N -/ in. (. mm) 0 -N -/ in. (. mm) 00 -N -/ in. (. mm) 00 -N in. (. mm) N Non-Metallic Conduit Connectors / in. (. mm) 0 0-N / in. ( mm) 0 0-N in. (. mm) 0 0-N0 -/ in. (. mm) 0 0-N -/ in. (. mm) 00 G Disconnect Switches 0-N in. (0. mm) 00 0-N -/ in. (. mm) 00 0-N in. (. mm) N Grounding dapters # 0 WG, / in. (. mm) 0 0-N # WG, / in. ( mm) 0 0-N0 # WG, in. (. mm) 0 0-N # WG, -/ in. (. mm) 0 0-N # /0 WG, -/ in. (. mm) 00 0-N # /0 WG, in. (0. mm) 00 0-N # /0 WG, -/ in. (. mm) 00 0-N # /0 WG, in. (. mm) N -0

241 Bulletin NEM Disconnect Switches ccessories, Continued V-L Decription For Use With Type Door Hardware Kit Includes: handle, cam, defeater actuator lever, rollers, and shims Enclosure Height less than 0 in. (0 mm) Top and Side (Right Hand) Top and Side (Left Hand) Enclosure Height 0 0 in. (0 mm) Top and Side (Right Hand) Bottom Top and Side (Left Hand) Bottom Enclosure Height greater than 0 in. ( mm) C, ll V V-L V-LL V-L and V-L V-LL and V-L V-L Top, Side and Bottom (Right Hand) V-L V-L Top, Side and Bottom (Left Hand) V-LL Type Door Hardware Kit Includes: Handle, cam, defeater actuator lever, rollers, and shims Enclosure Height less than 0 in. ( mm) Top and Side (Right Hand) Top and Side (Left Hand) Top and Bottom (Right Hand) Top and Bottom (Left Hand) Enclosure Height 0 in. ( mm) Top and Bottom (Right Hand) Side Top and Bottom (Left Hand) Side Enclosure Height greater than in. ( mm) F M, D F-L F-LL F-L F-LL F-L and F-L F-LL and F-L Top, Side, and Bottom (Right Hand) F-L and F-L Top, Side, and Bottom (Left Hand) F-LL Master Door Interlock Kits Interlock kits are designed to provide interlocking between the master and auxiliary doors of the same enclosure and for use with Cat. Nos. F-L and F- LL hardware kits or Cat. Nos. V-L and V-LL hardware kits. Specify one master door kit and as many auxiliary door kits as necessary ( maximum). Connecting bars must be supplied by user. C, F, M, D, V F-L F-N0 F-N0 uxiliary Door Interlock Kit F-N Door hardware kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. Door hardware kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. Master door interlock kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. If the Rockwell utomation door hardware kits are to be installed in a commercially available enclosure, consult the enclosure manufacturer's application data for proper kit selection. 0 -

242 0 Bulletin NEM Disconnect Switches Specifications Bulletin C, F, G, M, R, V Disconnect Switches Disconnect Switch Electrical Ratings Switch Size Rated insulation voltage Ui (UL) IEC (00) 0V 0V/0 Hz V/0 Hz HP Ratings V/0 Hz UL/CS/NEM 0V DC Continuous Current 00V C 0V DC uxiliary Contact Electical Ratings NEM/EEMC B00, P00 Ui 0V I th 0 IEC Ratings 0V 0 0V CII Ux 0 00V 00 00V I e.. Mechanical Degree of protection Operating Molded Type, R,, X,, Painted Type, R,, handles Stainless Steel Type, X Mechanical life (Typical) operations (0 00 ) operations (00 00 ) Switching frequency (operations/hr) 0, 0, 00, and 00 sizes 00 maximum 00 and 00 size 0 Maximum Environmental Temperature Operating - +0 C (- +0 F) Storage -0 + C (-0 + F) ltitude (per IEC -) 000m per IEC - Relative Humidity (per IEC -) 0% at 0 C and 0% at 0 C Design Specification/Test Requirements Dielectric strength 00V for minute Electrical life 000 operations at rated current Short Circuit Withstand Capability : unfused : with Class H fuses : with Class J or Class R fuses Construction Switch body material Phenolic Contact material Copper, tin-plated Terminals ll wire rated C ( F) or higher must be sized per the local Electric Code for C ( F) wire. Conductor Size (mm) Recommended Torque Mechanisms #0 - screw and self-lifting pressure plate / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper # WG (. 0 mm) # WG (. mm) # /0 WG (0 0 mm) # /0 WG ( mm) of #/0 WG 0 MCM ( per lug) of mm 0 MCM of #/0 WG 0 MCM ( per lug) of mm 0 MCM Conductor into Lug 0 lb in lb in 0 lb in lb in lb in lb in Zinc-plated steel, RoHS Compliant finish Lug to Terminal 0 lb in 0 lb in 0 lb in lb in lb in lb in -

243 Bulletin NEM Disconnect Switches Specifications, Continued Bulletin H Disconnect Switches Rated insulation voltage Ui (UL) IEC Ratings UL/CS/NEM Disconnect Switch Electrical Ratings Switch Size Hp 0V/0 Hz 0V/0 Hz V/0 Hz (00) 0V 0V DC Continuous 00V C Current 0V DC uxiliary Contact Electical Ratings Continuous Current 0 Pole Configuration DPDT DPDT Mechanical Degree of protection Operating handles Painted Type, R, Mechanical life (Typical) operations Switching frequency (operations/hr) 00 maximum Environmental Temperature Operating - +0 C (- +0 F) Storage -0 + C (-0 + F) ltitude (per IEC -) 000m per IEC - Relative Humidity (per IEC -) 0% at 0 C and 0% at 0 C Design Specification/Test Requirements Dielectric strength 00V for minute Electrical life 000 operations at rated current Short Circuit Withstand Capability Switch body material Contact material Terminals ll wire rated C ( F) or higher must be sized per the local Electric Code for C ( F) wire. Conductor Size (mm) Recommended Torque Mechanisms : unfused : with Class H fuses : with Class J or Class R fuses (0 00 ) : with Class J or Class R fuses (00 ) Construction Phenolic Copper, tin-plated 0 00 #0 - screw and self-lifting pressure plate / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper # WG # WG #0 /0 WG # 0 MCM WG Conductor into Lug 0 lb in lb in 0 lb in lb in Zinc-plated steel, Bronze chromate finish

244 Bulletin NEM Disconnect Switches Specifications, Continued Bulletin D, V Circuit Breakers Electrical Ratings Frame Size uxiliary Contacts V, D NEM/EEMC B00, P00 0V IEC Ratings CII Ux 0 0V 0 00V 00 00V I e.. Maximum Number of uxiliary Contacts Mechanical Data Mechanical Life (Typical) Construction Mechanisms Zinc-plated steel Environmental Data mbient Operating 0 +0 C ( +0 F) Temperature Storage 0 + C ( 0 + F) ltitude (per IEC -) 000 m per IEC - Relative Humidity (per IEC -) 0 C ( F), 0 C (0 F) Refer to circuit breaker specifications for other limitations. 0 Bulletin Fuse Blocks Electrical UL Fuse Type Class H Class J Class R Class C Class CC CS Fuse Type HRCI-H HRCI-J HRCI-R HRCI-C HRCI-MISC Maximum Fuse Cartridge Size Maximum Voltage C 00V 00V 00V 00V 00V DC 0V 0V 0V 0V 0V Thermal Current Rating Maximum Short Circuit Prospective Fault Current Fuse Clips Terminals Fuse Block Base Open mbient Temperature Enclosed Storage ltitude (per IEC -) Relative Humidity (per IEC -) 0 k 00 k 00 k 00 k 00 k Construction Tin-plated copper Tin-plated copper Phenolic or Porcelain Environmental 0 + C ( + F) 0 +0 C ( +0 F) 0 + C ( 0 + F) 000 m 0% at 0 C ( F) and 0% at 0 C (0 F) -

245 Bulletin NEM Disconnect Switches pproximate Dimensions pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin C, V Bulletin V 0 00 Bulletin V Disconnect Switches NEM Size [] Circuit Breakers -/ (0) -/ (0) -/ (0) -/ (0.) (.) -/ (.) B Max. Min. Max. -/ (0) -/ () -/ (.) -/ (.) -/ (.) -/ (.) pproximate dimensions are for reference only. This approximate dimension will vary by fuse class and size. pproximate dimension with Class J fuses. Frame 0U-H, 0M-H, EF, HMCPE 0 EHD, FD, FDB, FDC, HFD, HMCP 0 0U-J, 0M-J, EF 0 JD, JDB, JDC, HJD, HMCP 00 KD, KDB, KDC, HKD, HMCP (.) -/ (.) -/ (.) pproximate dimensions are for reference only. Min. -/ (.) -/ (00.0) -/ (00.0) -/ () -/ () -/ () -/ () () () C C Max. (.) -/ (.) -/ (.) -/ () -/ () -/ () -/ () -/ () -/ () D E F -/ (.) -/ (.) -/ (0.) -/ (.) (0.) (0.) -/ () -/ () -/ () -/ () 0 () -/ (00.) D E F (.) 0 () (0.) -/ (.) -/ (.) -/ (.0) -/ (.) -/ (.) -/ (.) -/ () -/ (.) -/ (.) () -/ (.) -/ (.) 0 -

246 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin F, M Disconnect Switches J 0 NEM Size [] B / (0.) -/ (0.) -/ (00.) 0-/ (.) -/ (0.) -/ (0.) -/ (00.) 0-/ (.) -/ (0.) -/ (0.) -/ (00.) 0-/ (.) 0-/ (.) -/ () -/ (.) 0-/ (.) 0-/ (.) -/ () -/ (.) 0-/ (.) 0-/ (.) -/ () -/ (.) 0-/ (.) Min. -/ (.) -/ (.) -/ (.) (.) -/ (.) -/ (.) -/ (.) (.) -/ (.) -/ (.) -/ (.) (.) Bulletin D Circuit Breakers C Max. D E F G H J K L P S -/ (.) (0.) () (.) Without Door Hardware -/ (0.) -/ (0.) -/ (0.) -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (0.) -/ (0.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) Small and Intermediate Enclosures with Door Hardware -/ (.) (0.) () (.) -/ (.) (0.) () (.) pproximate dimensions are for reference only. This approximate dimension will vary by fuse class and size. Minimum wiring space for the maximum wire size. Cutler-Hammer Frame -/ (0.) -/ (0.) -/ (0.) -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (0.) -/ (0.) -/ (.) Large Enclosures with Door Hardware -/ (0.) -/ (0.) -/ (0.) -/ () Min. -/ (.) -/ (.) -/ (.) -/ (.) C -/ (0.) -/ (0.) -/ (0.) -/ (.) Max. -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (0.) / (.) / (.) / (.) / (0.) / (.) / (.) / (.) / (0.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ () -/ () -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) D E F -/ (.) -/ (.) -/ (0.) 0-/ (.) -/ (.) -/ (.) -/ (0.) 0-/ (.) -/ (.) -/ (.) -/ (0.) 0-/ (.) 0 EHD, FD, FDB, FDC, HFD, HMCP -/ (.) -/ (.) (.) -/ (.) -/ (.) 0 JD, JDB, JDC, HJD, HMCP -/ (.) -/ (.) (0.) -/ (.) -/ (.) 00 KD, KDB, KDC, HKD, HMCP -/ (.) -/ (.) (0.) -/ (.) -/ (.) 00 LD, HLD, LDC, L, HL, LC, HLC -/ (.) -/ (.) (0.) (0.) 0-/ (.) 00 M, MDL, HMDL, HM, MC, ND, HND, NDC (0.) -/ (.) 0 () -/ (.) -/ (.) 00 NB TRI-PK (.) -/ (.) 0 () -/ (.) -/ (.) 00 HNC, ND, HND, NDC, NB, HNB, NC, HNC (0.) -/ (.) (0.) -/ (.) -/ (.) pproximate dimensions are for reference only. -

247 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin G, GX, GY Enclosed Disconnect Safety Switches Type R// (Enclosure Code "F") Painted Metal Enclosures Size [] Fuse Style Number of Poles Bulletin No. 0 0 or G 0 B 0 or G 00 0 C D 0 C D G 0 B 0 B or GY 0 B 0 B or GX 00 D G 00 B or GY B or 00 C 00 or B G 00 B or GX 00 C D G 00 B or GY or G 00 B 00 B or G Height / () 0 (0) / () 0 () / (00) 0 (0) 0 (0) () B Width 0 / () 0 / () 0 / () 0 / () 0 / () () () 0 / () pproximate Dimensions in Inches (Millimeters) C Depth / (0) 0 / () / (0) 0 / () 0 / () / () / () / (0) D Mounting / () / () / () / () / () / (0) / (0) / () E Mounting / () / () / () 0 (0) F Mounting / () / () / () / () / () / () / () / () G Handle Depth H J / () / () / () / () / () / () / () / () / () / () / () / () / (0) / (0) / (0) / (0) = Non-Fusible, Fusible 0V - Class H/R, Fusible 00V - Class J B = Fusible 00V - Class H/R C = Non-fusible D = Fusible 0V - Class H/R, Fusible 00V - Class J These enclosures have one top mounting hole located on the center line. ll other enclosures have two top mounting holes located as shown. / () / () / () / () / () / () / () (.) pprox. Shipping Weight in lbs (kg) 0 (.0) 0 (.) 0 (.) 0 (0.) 0 (.) 00 (0.) 00 (0.) 00 (.0) - 0

248 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin G, GX, GY Enclosed Disconnect Safety Switches Type /X (Enclosure Code "C") Stainless Steel Enclosure 0 Size [] Fuse Style Number of Poles Bulletin No. or G B or C D B or C D B B B B B C D B B C D B B G or GY or GX or G or GX or G or G Height / () / () 0 () 0 (0) () B Width 0 / () 0 / () 0 / () () 0 / () pproximate Dimensions in Inches (Millimeters) C Depth / () / (0) / () / () / (0) D Mounting / () / () / () / (0) / () E Mounting () / (0) 0 (0) F Mounting / () () () / (0) / () G Handle Depth H J / () / () / () / () / () / () / () / () / () / () = Non-Fusible, Fusible 0V - Class H/R, Fusible 00V - Class J B = Fusible 00V - Class H/R C = Non-fusible D = Fusible 0V - Class H/R, Fusible 00V - Class J These enclosures have one top mounting hole located on the center line. ll other enclosures have two top mounting holes located as shown. / () / () / () / () (.) pprox. Shipping Weight in lbs (kg) 0 (.0) 0 (.) 0 (0.) 00 (0.) 00 (.0) -

249 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin G, GX, GY Enclosed Disconnect Safety Switches Type /X (Enclosure Code "S") Non-metallic, Corrosion-resistant Enclosure Size [] Fuse Style B B B B B Number of Poles Bulletin No. or G or GX G = Non-fusible, Fusible 0V - Class H/R, Fusible 00V - Class J/H/R B = Fusible 00V - Class H/R Height (0) (0) pproximate Dimensions in Inches (Millimeters) B Width 0 () () C Depth / () / () D Handle Depth / () / () pprox. Shipping Weight in lbs (kg) (.) 0 (.) 0 -

250 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin H Safety Switches Type (Enclosure Code "") Painted Metal Enclosures B C Switch Size [] Fuse Style Knockouts Conduit Size Height D B Width C Depth D Width (with handle) Knockout Fig. # 0V 0-/ (.) -/ (.) -/ (.) -/ () 00V -/ (0.) -/ (.) (0.) -/ (.) Non-fusible 0-/ (.) -/ (.) (0.) -/ () 0V -/ (.) 00V -/ (.) Non-fusible -/ (.) 0V -/ () -/ (.) () 0-/ (.) 00V -/ (.) -/ (.) () 0-/ (.) Non-fusible -/ (.) 0V 00V Non-fusible -/ (0.) -/ (.) -/ (.) -/ (.) C C D D C C C C E E H D E C J J H J E H H J H J J E H H K K K B K K K K C C C C K K K K 0 C D Switch Size [] C E D E H D E H E H J Knockouts B C D F G H J K 0 / (.) / (.) / (.) / (.) / (.) (.) (.) 0 / (.) / (.) (.) -/ (.) -/ (.) 00 -/ (.) -/ (.) (0.) 00 -/ (.) (0.) -/ (.) H E J H E H J H E J B K K K Fig. Fig. Fig. Fig. Fig. -0

251 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin H Safety Switches Type R (Enclosure Code "N") Painted Metal Enclosures B C Switch Size [] Fuse Style Height D B Width C Depth D Width (with handle) Knockout Fig. # 0V 0-/ (.) -/ (.) -/ (.) -/ () 00V -/ (.) -/ (.) (0.) -/ (.) Non-fusible -/ (.) -/ (.) (0.) -/ (.) 0V -/ (.) 0-/ (.) 00V -/ (.) -/ (0.) () 0-/ (.) Non-fusible -/ (.) 0-/ (.) 0V -/ (.) 00V -/ (.) -/ (0.) () 0-/ (.) Non-fusible -/ (.) 0-/ (.) 0V 00V Non-fusible -/ (00.) (.) -/ (.) -/ (.) Knockouts Conduit Size C C C C E C E E H C H E H H C D C Fig. Fig. Fig. Fig. Switch Size Knockouts [] B C D F G H J K 0 / (.) / (.) / (.) / (.) / (.) (.) (.) 0 / (.) / (.) (.) -/ (.) -/ (.) 00 -/ (.) -/ (.) (0.) 00 -/ (.) (0.) -/ (.) H J E K K K K K K K 0 -

252 Bulletin NEM Disconnect Switches pproximate Dimensions, Continued pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin H Safety Switches Type (Enclosure Code "F") Painted Metal Enclosures B C Switch Size [] Fuse Style D Height B Width C Depth D Width (with handle) 0V -/ (.) -/ (.) -/ (.) -/ (0.) 00V -/ (.) -/ (.) -/ (.) Non-fusible -/ (.) 0V -/ (.) 00V -/ (.) -/ (.) -/ (.) Non-fusible -/ (.) 0V 00V Non-fusible 0V 00V Non-fusible 0-/ (0.) 0-/ (0.) -/ (.) -/ (.) -/ (.) -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) 0 -

253 Bulletin, 00H Definite-Purpose Style Enclosures Product Overview Definite-Purpose Style Enclosures Bulletin, 00H Description General-Purpose Enclosure Junction Box Push Button Enclosure Features Dimensions (in mm) Degree of Protection Designed for use as an automation control box, electrical control housing, and terminal wiring box in industrial and commercial applications vailable in sizes (Height x Width x Depth) Designed for use as a junction box, terminal wiring box, and small automation control box in industrial and commercial applications vailable in sizes (Height x Width x Depth) Designed to house. mm (Bul. ) and 0. mm (Bul. 00H) push buttons (available in grey or yellow colors) vailable in sizes (Height x Width x Depth) 0 x 0 x 0 x 0 x 0 -Hole (. mm): 0 x 0 x x x 0 0 x 0 x 0 x 0 x 0 x 0 x -Hole (0. mm): 0 x 0 x 0 0 x 0 x 0 x 0 x 0 0 x 0 x 0 0 x 0 x -Hole: 0 x 0 x 0 x 0 x 0 0 x 0 x 0 -Hole: 0 x 0 x 0 x 0 x 0 -Hole: 0 x 0 x 0 x 0 x 0 0 x 0 x 0 0 x 0 x 0 0 x 0 x 0 Type, R,, X,, IP Indoor/Outdoor Type, R,, X,, IP Indoor/Outdoor Type,, X,, IP Indoor/Outdoor Storage Temperature Range -0 + C (-0 + F) -0 + C (-0 + F) -0 + C (-0 + F) Operating Temperature Range -0 + C (-0 + F) -0 + C (-0 + F) -0 + C (-0 + F) Material Enclosure Thermoplastic polyester blend, UL-V Thermoplastic polyester blend, UL-V Thermoplastic polyester blend, UL-V Gasket Foam-in place polyutherane Foam-in place polyutherane Foam-in place polyutherane Plastic Mounting Panel BS BS Metal Mounting Panel Steel plus zinc with chromate plating Steel plus zinc with chromate plating Standards UL 0 and CS C., No. Certifications culus, CE Product Selection Page - Page - Page - (. mm) Page - (0. mm) 0 -

254 Bulletin General Purpose Enclosure Specifications Bulletin General Purpose Enclosure Type R,, X,, and rainproof, watertight, corrosion resistant, and dusttight, IP protection Designed for use as automation control box, electrical control housing, and terminal wiring box in industrial and commercial applications vailable with optional plastic or metal mounting plates Provision for mounting using either B or DIN Rail Enclosure can accommodate both panel mount and rail mount terminal blocks Designed for use in both indoor and outdoor applications Table of Contents Specifications... this page Product Selection... - ccessories... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) CE Marked Technical Specifications Product Certification pprovals/certifications culus, CE Degree of Protection Type R,, X,, and, IP Environmental Storage Temperature Range -0 + C (-0 + F) Operating Temperature Range -0 + C (-0 + F) Material Enclosure Solid Base & Cover Thermoplastic polyester blend, UL V Enclosure Clear Cover Polycarbonate, UL V Gasket Foam-in-place polyurethane Plastic Mounting Plate BS Metal Mounting Plate Steel plus zinc with chromate plating Mounting Plate Hardware (included with enclosure) Stainless Steel Mounting Provision Brass External Mounting Bracket Stainless Steel Hinges & Latches Stainless Steel Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. 0 -

255 Bulletin General Purpose Enclosure Product Selection -BS Enclosure Outside Dimensions (H x W x D) Pkg. Quantity -BS Pkg. Quantity -BS -BS -BS -BS 0 x 0 x mm (. x. x. in.) 0 x 0 x mm (.0 x. x. in.) 0 x 0 x mm (. x. x. in.) Base Depth 0 mm (. in.) 0 mm (. in.) 0 mm (. in.) Cover Depth mm (. in.) mm (. in.) mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Glass-reinforced nylon Recommended Tightening Torque.0. N m ( lb-in.).0. N m ( lb-in.).0. N m ( lb-in.) pprox. Ship Weight g (0.0 lb) g (0. lb) g (0. lb) Pkg. Quantity Plastic Mounting Plate Outside Dimension (H x W x Thickness) Recommended hardware for installing components Pkg. Quantity Pkg. Quantity -PP -PP -PP x x. mm (. x. x 0. in.). x x. mm (. x. x 0. in.) x x. mm (. x. x 0. in.) M (#) M (#) M (#) pprox. Ship Weight. g (0.0 lb).0 g (0.0 lb). g (0.0 lb) Pkg. Quantity Metal Mounting Plate Outside Dimension (H x W x Thickness) Pkg. Quantity Pkg. Quantity -PM -PM -PM x x. mm (. x. x 0.0 in.). x x. mm (. x. x 0.0 in.) x x. mm (. x. x 0.0 in.) pprox. Ship Weight. g (0. lb). g (0. lb) g (0.0 lb) Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. Dimensions are not intended to be used for manufacturing purposes. Pkg. Quantity 0 -

256 Bulletin General Purpose Enclosure Product Selection, Continued -BS Enclosure Lift-Off Solid Cover -DSM -BS Pkg. Quantity -BS -BS -BS Pkg. Quantity -DSM -BS Lift-Off Clear Cover -BSC -BSC -BSC Hinged Solid Cover -DSM -DSM -DSM Hinged Clear Cover -DSCM -DSCM -DSCM Outside Dimensions (H x W x D) 0 x 0 x 0 mm (. x. x. in.) 0 x 0 x 0 mm (.0 x. x. in.) 0 x 0 x 0 mm (.0 x.0 x. in.) Base Depth mm (. in.) mm (. in.) mm (. in.) Cover Depth 0 mm (. in.) 0 mm (. in.) 0 mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Glass-reinforced nylon Cover Plug Material (for hinged enclosures only) Recommended Tightening Torque Polypropylene Polypropylene Polypropylene.. N m ( lb in).. N m ( lb in).. N m ( lb in) pprox. Ship Weight 0. g (. lb) g (. lb) 0 g (. lb) Pkg. Quantity Plastic Mounting Plate Outside Dimension (H x W x Thickness) Thickness at support bracket Recommended hardware for installing components Pkg. Quantity Pkg. Quantity -PP -PP -PP 0 x 0 x mm (. x. x 0. in.) mm (0. in.) x x. mm (. x. x 0. in.) mm (0. in.) x x. mm (0. x 0. x 0. in.) mm (0. in.) M (#) M (#0) M (#0) pprox. Ship Weight. g (0. lb). g (0. lb) 0. g (0. lb) Pkg. Quantity 0 Metal Mounting Plate Outside Dimension (H x W x Thickness) Pkg. Quantity Pkg. Quantity -PM -PM -PM x x. mm (. x. x 0.0 in.). x x. mm (. x. x 0.0 in.) x x. mm (. x. x 0.0 in.) pprox. Ship Weight. g (0.0 lb) 00. g (.0 lb). g (. lb) Stainless Steel External Mounting Bracket (including mounting hardware) Pkg. Quantity Pkg. Quantity -N -N -N pprox. Ship Weight. g (0.0 lb). g (0.0 lb). g (0.0 lb) Stainless Steel Hinge & Latch Kit Number of Kits to Convert Lift-Off to Hinged Pkg. Quantity Pkg. Quantity -NHLM -NHLM -NHLM pprox. Ship Weight g (0. lb) g (0. lb) g (0. lb) Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. Clear cover material: polycarbonate. Dimensions are not intended to be used for manufacturing purposes. Pkg. Quantity Pkg. Quantity Pkg. Quantity -

257 Bulletin General Purpose Enclosure Product Selection, Continued -BS Enclosure Lift-Off Solid Cover -DSCM -BS Pkg. Quantity -BS -BS -BS Pkg. Quantity -DSCM -BS Lift-Off Clear Cover -BSC -BSC -BSC Hinged Solid Cover -DSM -DSM -DSM Hinged Clear Cover -DSCM -DSCM -DSCM Outside Dimensions (H x W x D) x 0 x 0 mm (. x.0 x. in.) x x 0 mm (.0 x. x.0 in.) 0 x 0 x 0 mm (. x.0 x.0 in.) Base Depth 00 mm (. in.) mm (. in.) mm (. in.) Cover Depth 0 mm (. in.) 0 mm (. in.) 0 mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Glass-reinforced nylon Cover Plug Material (for hinged enclosures only) Recommended Tightening Torque Polypropylene Polypropylene Polypropylene.. N m ( lb in).. N m ( lb in).. N m ( lb in) pprox. Ship Weight g (. lb) g (. lb) 0 g (. lb) Pkg. Quantity Plastic Mounting Plate Outside Dimension (H x W x Thickness) Thickness at support bracket Recommended hardware for installing components Pkg. Quantity Pkg. Quantity -PP -PP -PP 00 x 0 x mm (. x. x 0. in.) mm (0. in.) x x mm (. x.0 x 0. in.) mm (0. in.) x x. mm (. x. x 0. in.) mm (0. in.) M (#) M (#) M (#) pprox. Ship Weight. g (0. lb). g (0. lb). g (0. lb) Metal Mounting Plate Outside Dimension (H x W x Thickness) Pkg. Quantity Pkg. Quantity -PM -PM -PM x x. mm (. x. x 0.0 in.). x x. mm (. x. x 0.0 in.) x x. mm (. x. x 0.0 in.) pprox. Ship Weight. g (. lb) 0. g (. lb) 0. g (.0 lb) Stainless Steel External Mounting Bracket (including mounting hardware) Pkg. Quantity Pkg. Quantity -N -N -N pprox. Ship Weight. g (0.0 lb). g (0.0 lb). g (0.0 lb) Stainless Steel Hinge & Latch Kit Number of Kits to Convert Lift-Off to Hinged Pkg. Quantity Pkg. Quantity -NHLM -NHLM -NHLM pprox. Ship Weight g (0. lb) g (0. lb) g (0. lb) Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. Clear cover material: polycarbonate. Dimensions are not intended to be used for manufacturing purposes. Pkg. Quantity Pkg. Quantity Pkg. Quantity Pkg. Quantity 0 -

258 Bulletin General Purpose Enclosure Product Selection, Continued -BS Enclosure Pkg. Quantity Lift-Off Solid Cover -BS -BS Lift-Off Clear Cover -BSC -BSC Hinged Solid Cover -DSM -DSM Hinged Clear Cover -DSCM -DSCM Outside Dimensions (H x W x D) -BS 0 mm x 0 mm x 0 mm (.0 in. x.0 in. x. in.) -DSCM 0 mm x 0 mm x 0 mm (.0 in. x. in. x.0 in.) Base Depth mm (. in.) mm (. in.) Cover Depth 0 mm (. in.) 0 mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Cover Plug Material (for hinged enclosures only) Polypropylene Polypropylene Recommended Tightening Torque.. N m ( lb in).. N m ( lb in) pprox. Ship Weight g (. lb) g (. lb) Pkg. Quantity Plastic Mounting Plate Outside Dimension (H x W x Thickness) Thickness at support bracket Recommended hardware for installing components Pkg. Quantity Pkg. Quantity -PP x x. mm (. x. x 0. in.) mm (0. in.) M (#) pprox. Ship Weight. g (0. lb) 0 Metal Mounting Plate Outside Dimension (H x W x Thickness) Stainless Steel External Mounting Bracket (including mounting hardware) Pkg. Pkg. Quantity Quantity -PM -PM mm x. mm x. mm (0. in. x 0.0 in. x 0.0 in.) mm x. mm x. mm (0. in. x. in. x 0.0 in.) pprox. Ship Weight g (. lb) g (. lb) Pkg. Quantity -N -N pprox. Shipping Weight. g (0.0 lb). g (0.0 lb) Pkg. Quantity Pkg. Pkg. Stainless Steel Quantity Quantity Hinge & Latch Kit -NHLM -NHLM Number of Kits to Convert Lift-Off to Hinged pprox. Ship Weight g (0. lb) g (0. lb) Clear cover material: polycarbonate. Must order two pieces for this enclosure. Dimensions are not intended to be used for manufacturing purposes. -

259 Bulletin Junction Box Technical Specifications Bulletin Junction Box Type R,, X,, and rainproof, watertight, corrosion resistant, and dusttight, IP protection Designed for use as a junction box, terminal wiring box, and small automation control box in industrial and commercial applications vailable with optional plastic or metal mounting plates Provision for mounting using either B or DIN Rail Enclosure can accommodate panel mount or rail mount terminal blocks Designed for use in both indoor and outdoor applications Table of Contents Specifications... this page Product Selection ccessories... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) CE Marked Technical Specifications Product Certification pprovals/certifications culus, CE Degree of Protection Type R,, X,, and, IP Environmental Storage Temperature Range -0 + C (-0 + F) Operating Temperature Range -0 + C (-0 + F) Material Enclosure Thermoplastic polyester blend, UL, V Gasket Foam-in-place polyurethane Plastic Mounting Plate BS Metal Mounting Plate Steel plus zinc with chromate plating Mounting Plate Hardware (included with enclosure) Stainless steel Mounting Provision Brass External Mounting Bracket Stainless steel Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. 0 -

260 Bulletin Junction Box Product Selection -BS -BS -BS Enclosure Outside Dimensions (H x W x D) Pkg. Quantity Pkg. Quantity -BS -BS -BS 0 x 0 x. mm (. x. x.0 in.) x x. mm (. x. x.0 in.) 0 x 0 x mm (. x. x. in.) Base Depth mm (. in.) mm (. in.) 0 mm (. in.) Cover Depth. mm (0. in.). mm (0. in.) mm (. in.) Cover Screw Material Stainless steel Stainless steel Glass-reinforced nylon Recommended Tightening Torque 0..0 N m ( lb in) 0..0 N m ( lb in).0. N m ( lb in) pprox. Ship Weight 0 g (0. lb) g (0. lb) g (0.0 lb) Width Height Pkg. Quantity Plastic Mounting Plate Outside Dimension (H x W x Thickness) Recommended hardware for installing components Pkg. Quantity Molded-In Molded-In -PP. mm x. mm x. mm (. in. x.0 in. x 0. in.). mm x. mm x. mm (. in. x. in. x 0. in.) x x. mm (. x. x 0. in.) M (#) M (#) M (#) pprox. Ship Weight. g (0.0 lb) Not vailable Not vailable 0 Metal Mounting Plate Outside Dimension (H x W x Thickness) Pkg. Quantity -PM x x. mm (. x. x 0.0 in.) pprox. Ship Weight. g (0. lb) Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. Dimensions are not intended to be used for manufacturing purposes. -0

261 Bulletin Junction Box Product Selection, Continued -BS Enclosure Outside Dimensions (H x W x D) Pkg. Quantity -BS Pkg. Quantity -BS -BS -BS -BS 0 x 0 x mm (.0 x. x. in.) 0 x 0 x mm (. x. x. in.) 0 x 0 x 0 mm (. x. x. in.) Base Depth 0 mm (. in.) 0 mm (. in.) mm (. in.) Cover Depth mm (. in.) mm (. in.) 0 mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Glass-reinforced nylon Recommended Tightening Torque.0. N m ( lb in).0. N m ( lb in).. N m ( lb in) pprox. Ship Weight g (0. lb) g (0. lb) 0. g (. lb) Pkg. Quantity Plastic Mounting Plate Outside Dimension (H x W x Thickness) Recommended hardware for installing components Pkg. Quantity Pkg. Quantity -PP -PP -PP. x x. mm (. x. x 0. in.) x x. mm (. x. x 0. in.) 0 x 0 x mm (. x. x 0. in.) M (#) M (#) M (#) pprox. Ship Weight.0 g (0.0 lb). g (0.0 lb). g (0. lb) Pkg. Quantity Metal Mounting Plate Outside Dimension (H x W x Thickness) Pkg. Quantity Pkg. Quantity -PM -PM -PM. x x. mm (. x. x 0.0 in.) x x. mm (. x. x 0.0 in.) x x. mm (. x. x 0.0 in.) pprox. Ship Weight. g (0. lb) g (0.0 lb). g (0.0 lb) Note: In applications where there is shock and vibration, use of metal mounting plate is recommended. Dimensions are not intended to be used for manufacturing purposes. For -BS clear & hinged covers, see page -. Pkg. Quantity 0 -

262 Bulletin Terminal Block Compatibility ccessories Note: The table below lists suggested types of terminal blocks suitable for mounting on the plastic grid in the junction box. Items in table are not pre-assembled and are sold separately. -BS -BS -BS -BS -BS -BS Junction Box Mounting Options for use with Panel Mount Terminal Blocks Types of Terminal Blocks Suitable for Mounting on Plastic Grid in Junction Box Barrier Strips Molded-In Molded-In -PP -PP -PP -PP Maximum Number of Poles (pproximation) Panel Mount Blocks with predefined set of poles -EC & -ED0 -HC 0 Panel Mount Interlocking Blocks Rail Mount Terminal Blocks -HJ & -HJ -T & -T -C -F -H -W -J -L Requires B or DIN Rail for mounting For barrier strip with typical 0. in. pitch spacings. -

263 Bulletin. mm Push Button Enclosure Technical Specifications Bulletin. mm Push Button Enclosure Pre-molded. mm mounting hole vailable in two colors: Grey enclosures: Type, X,, and watertight, corrosion resistant, and dusttight, IP protection Yellow enclosures: Type, X,, and watertight, corrosion resistant, and dusttight, IP protection vailable in these configurations: -hole -hole -hole -hole Designed for both indoor and outdoor applications Table of Contents Specifications... this page Product Selection... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) CE Marked Technical Specifications Product Certification pprovals/certifications culus, CE Degree of Protection Type, X,, and, IP Environmental Storage Temperature Range -0 + C (-0 + F) Operating Temperature Range -0 + C (-0 + F) Material Enclosure Thermoplastic polyester blend, UL V Gasket Foam-in-place polyurethane 0 -

264 Bulletin. mm Push Button Enclosure Product Selection Enclosure Pkg. Quantity Gray Enclosure -PBG -PBG Yellow Enclosure -PBY -PBY Outside Dimensions (H x W x D) -PB 0 mm x 0 mm x mm (. in. x. in. x. in.) -PB 0 mm x 0 mm x mm (. in. x. in. x. in.) Base Depth 0 mm (. in.) 0 mm (. in.) Cover Depth mm (. in.) mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Recommended Tightening Torque.0. N m ( lb in).0. N m ( lb in) pprox. Ship Weight g (0. lb) g (0.0 lb) Pkg. Quantity Enclosure -PB -PB Pkg. Quantity Gray Enclosure -PBG -PBG Yellow Enclosure -PBY -PBY Outside Dimensions (H x W x D) 0 mm x 0 mm x mm (.0 in. x. in. x. in.) 0 mm x 0 mm x mm (. in. x. in. x. in.) Base Depth 0 mm (. in.) 0 mm (. in.) Cover Depth mm (. in.) mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Recommended Tightening Torque.0. N m ( lb in).0. N m ( lb in) pprox. Ship Weight g (0. lb) g (0. lb) Note: Holes are pre-molded to fit. mm push buttons, such as the llen-bradley Bulletin 00F. Dimensions are not intended to be used for manufacturing purposes. Pkg. Quantity For information on legend plates and contact blocks, see Legend Plate Compatibility/Options and Contact Block Compatibility/Options on page

265 Bulletin 00H 0. mm Push Button Enclosure Technical Specifications Bulletin 00H 0. mm Push Button Enclosure Pre-molded 0. mm mounting hole vailable in two colors: Grey enclosures: Type, X,, and watertight, corrosion resistant, and dusttight, IP protection Yellow enclosures: Type, X,, and watertight, corrosion resistant, and dusttight, IP protection vailable in these configurations: -hole -hole -hole -hole Designed for both indoor and outdoor applications. Table of Contents Technical Specifications... this page Product Selection... - pproximate Dimensions... - Standards Compliance UL 0 CS C., No. Certifications culus Listed (File No. E, Guide No. NITW, NITW) CE Marked Technical Specifications Product Certification pprovals/certifications culus, CE Degree of Protection Type, X,, and, IP Environmental Storage Temperature Range -0 + C (-0 + F) Operating Temperature Range -0 + C (-0 + F) Material Enclosure Thermoplastic polyester blend, UL, V Gasket Foam-in-place polyurethane 0 -

266 Bulletin 00H 0. mm Push Button Enclosure Product Selection 00H-HZ 00H-HZ Enclosure Pkg. Quantity Gray Enclosure 00H-HZC 00H-HZC Yellow Enclosure 00H-HZCY 00H-HZCY Outside Dimensions (H x W x D) 0 mm x 0 mm x 0 mm (. in. x. in. x. in.) 0 mm x 0 mm x mm (. in. x. in. x. in.) Base Depth 0 mm (. in.) 0 mm (. in.) Cover Depth 0 mm (0. in.) mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Recommended Tightening Torque.0. N m ( lb in).0. N m ( lb in) pprox. Ship Weight g (0. lb) g (0.0 lb) Pkg. Quantity Enclosure Pkg. Quantity Gray Enclosure 00H-HZC 00H-HZC Yellow Enclosure 00H-HZCY 00H-HZCY Outside Dimensions (H x W x D) 00H-HZ 0 mm x 0 mm x mm (.0 in. x. in. x. in.) 00H-HZ 0 mm x 0 mm x mm (. in. x. in. x. in.) Base Depth 0 mm (. in.) 0 mm (. in.) Cover Depth mm (. in.) mm (. in.) Cover Screw Material Glass-reinforced nylon Glass-reinforced nylon Recommended Tightening Torque.0. N m ( lb in).0. N m ( lb in) pprox. Ship Weight g (0. lb) g (0. lb) Note: Holes are pre-molded to fit 0. mm push buttons, such as the llen-bradley Bulletin 00T and 00H. Dimensions are not intended to be used for manufacturing purposes. Pkg. Quantity 0 For information on legend plates and contact blocks, see Legend Plate Compatibility/Options and Contact Block Compatibility/Options on page -. -

267 Bulletin 00H 0. mm Push Button Enclosure Product Selection, Continued Legend Plate Compatibility/Options. mm Push Button Enclosure Contact Block Compatibility/Options 0. mm Push Button Enclosure. mm Push Button Enclosure 0. mm Push Button Enclosure Note: Pictures are for illustrative purposes only, depicting suitable legend plates and contact blocks that would fit in and on the Bul. /00H push button plastic enclosure. Please reference the appropriate selection guides for more dimensional information. 0 -

C 2 5 D N A A A

C 2 5 D N A A A Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,

More information

Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page Max. Hp Rating Fuse Clip Type 3R/4/12

Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page Max. Hp Rating Fuse Clip Type 3R/4/12 Bulletin NEM Combination Reversing Starters Product Selection Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard,

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

ALLEN BRADLEY RELAY Bulletin 700-HF

ALLEN BRADLEY RELAY Bulletin 700-HF ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)

More information

Series CA7 Contactors

Series CA7 Contactors C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

Series CA7 Contactors

Series CA7 Contactors Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.

More information

Series CA9 Contactors

Series CA9 Contactors Series C9 Contactors Sprecher + Schuh s C9 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this wide horsepower range. C9 contactors offer a

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil

More information

800 T A 1 A. f (cont'd) d (cont'd) f (cont'd) Momentary Contact Push Button Devices, Non-Illuminated. Rockwell Automation Publication 800-TD009A-EN-P

800 T A 1 A. f (cont'd) d (cont'd) f (cont'd) Momentary Contact Push Button Devices, Non-Illuminated. Rockwell Automation Publication 800-TD009A-EN-P NEM Push Button Specifications 800T/H 30.5 mm Push Buttons Momentary Contact Push Button Devices, Non-Illuminated Flush Head Unit Cat. No. 800T-1 Extended Head Unit Cat. No. 800T-B6 Booted Unit Cat. No.

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

Cat. No. (Spring Clamp. Input Voltage

Cat. No. (Spring Clamp. Input Voltage Bulletin -HL Product Overview/Product Selection Product Selection Bulletin -HL "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Bulletin 1494H Heavy Duty Safety Switches

Bulletin 1494H Heavy Duty Safety Switches ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description 9 Bulletin 700-HA Bulletin 700-HA 10 A Rating DPDT 3PDT Pin Style Terminals Standard ON/OFF Flag Indicator Finger Grips for Easy Installation and Removal Optional Manual Operator Optional Pilot Light Optional

More information

Bulletin 700-HA Tube Base Relay

Bulletin 700-HA Tube Base Relay Bulletin 700-HA Tube Base Relay Bulletin 700 HA Tube Base Relay 10 A contact rating DPDT, 3PDT Pin-style terminals Standard ON/OFF flag indicator Options: LED, push-to-test and manual override, socket-mounted

More information

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13 2-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A a b c d e a Protection Rating T Metal, Type 4/13 Blank C H31 H32 H33

More information

Bulletin 817 Thermistor Protection Relay

Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output

More information

XMC0 Series. Features. Type model nomenclature - Ordering Information. Definite Purpose Contactors. Description

XMC0 Series. Features. Type model nomenclature - Ordering Information. Definite Purpose Contactors. Description XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1pole, 1pole+shunt, pole, pole(optional Auxiliary Contact Blocks or Microswitch Blocks

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Bulletin 700-HL 2-Pole Terminal Block Relay

Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Complete UL/CSA Disconnect Switch Kits

Complete UL/CSA Disconnect Switch Kits Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC

More information

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2 ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

Allen-Bradley 700-K40E-DJ

Allen-Bradley 700-K40E-DJ Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode

More information

Electronic Motor Protection Relays Bulletin 193-E

Electronic Motor Protection Relays Bulletin 193-E Electronic otor Protection Relays Bulletin 93-E 93-EB also includes: Trip Class 0, or 0 selectable Ground Fault Protection Jam/Stall Protection Product Selection... -3 ccessories dd-on ccessories... -

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Latching, Sequence and Impulse Relays Application Data

Latching, Sequence and Impulse Relays Application Data Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

onlinecomponents.com

onlinecomponents.com ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

Product Certification. Approvals/Certifications. Environmental. Foam-in-place polyurethane. Plastic Mounting Plate

Product Certification. Approvals/Certifications. Environmental. Foam-in-place polyurethane. Plastic Mounting Plate ulletin eneral Purpose nclosures Specifications ulletin eneral Purpose nclosures Type R,, X,, and rainproof, watertight, corrosion resistant, and dusttight, IP protection Designed for use as automation

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable f padlocks) E-FA Painted Steel Enclosure

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Allen-Bradley Drives

Allen-Bradley Drives Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Universal Tongue-Operated Safety Interlock Switch

Universal Tongue-Operated Safety Interlock Switch Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

CI-tronic Soft start motor controller

CI-tronic Soft start motor controller MAKING MODERN LIVING POSSIBLE CI-tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Technical brochure Contents Page Soft start motor controller, MCI 3, MCI

More information

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,

More information

IEC Contactor Specifications

IEC Contactor Specifications Technical Data IEC Contactor Specifications Bulletin Numbers 00/0-K, 00/0-C, 00/0S-C, 00/0-D, 00S-D, 00-G, 00Q-C Topic Page Product Line Overview 00-K/0-K Miniature Contactors Coil Voltage Codes Assignment

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell utomation Inc. 101 South nd Street Milwaukee, WI 504 U.S.. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,

More information

Actuator Terminal Model

Actuator Terminal Model Sealed Snap ction Switch D2VW Watertight Miniature Snap ction Switch High-quality watertight, high-precision miniature Snap ction switch. Switch Body meets IP67 requirements Use of epoxy resin assures

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

Brasch Washdown Unit Heaters

Brasch Washdown Unit Heaters Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt

More information

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D Circuit Protection Disconnect Switches Thermal Overload Relays n extended operational service life is one of the main features you can find in RW overload relays. WEG s RW Thermal Overload Relays are designed

More information

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC Characteristics module XPS-MP - 2 independent functions - 24 V DC Main Range of product Product or component type Safety module name Safety module application 1-Nov-2018 Preventa Safety automation Safety

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC

KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC P& KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 mp 150VDC Load Switching KUMP 15 mp 2VC File E2255 File LR1534 0435 Registration 12 (KUIP) 0435

More information

New Solutions. for AC Motor Starters

New Solutions. for AC Motor Starters ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121 Snap ction Switch V General Purpose Snap ction Switch Industry standard design with switching currents of 10 to 21 Widely used for applications where long life expectancy and high reliability is required.

More information

CI-tronic Reversing contactor Type RCI

CI-tronic Reversing contactor Type RCI Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 850R miniature control relays 850RS4 standard 850RS24 low level 850RS34 hermetically sealed Catalog 204 Contents Class 850R miniature control relays bbspecifications....................................................

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

140M C 2 N A63 KN CC GJ

140M C 2 N A63 KN CC GJ Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating

More information