Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Size: px
Start display at page:

Download "Varius SUMMARY OF MODELS OF HRC FUSE-LINKS"

Transcription

1 SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size Utilization category of the fuse-link gg, am gg gg, am gg Use Fuse switch-disconnectors FH000.., FH00.. FH00.. Fuse switch-disconnectors of vertical design FSD00.. Fuse-rails FSR00.. Fuse-bases SPB00, SPB00, SPF00 Accessories Signal contact VL0 Signalling of fuse-link state MD-M Disconnecting link ZP000 Replacement handles D1PH, DP, DPM E

2 SUMMARY OF MODELS OF HRC FUSE-LINKS PNA1 PHNA1 PNA PHNA Rated current I n up to 0 A up to 00 A up to 00 A up to 1 A Rated voltage U n AC 00 V, 90 V 90 V 00 V, 90 V 90 V DC 0 V, 0 V 0 V 0 V, 0 V 0 V Fuse-link size 1 1 Utilization category of the fuse-link gg, am gg gg, am gg Use Fuse switch-disconnectors FH1.. FH.. Fuse switch-disconnectors of vertical design FSD1.. FSD.. Fuse-rails FSR1.. FSR.. Fuse-bases SPB1, SPB1, SPF1 SPB, SPB, SPF Accessories Signal contact VL0 Signalling of fuse-link state MD-M Disconnecting links ZP1 ZP Replacement handles D1PH, DP, DPM E

3 SUMMARY OF MODELS OF HRC FUSE-LINKS PNA / PN PHNA PNa PHNa Rated current I n up to 0 A up to 00 A up to 1 00 A up to A Rated voltage U n AC 00 V, 90 V 90 V 00 V 90 V DC 0 V, 0 V 0 V 0 V 0 V Fuse-link size a a Utilization category of the fuse-link gg, am gg gg gg Use Fuse switch-disconnectors FH.. LTLa Fuse switch-disconnectors of vertical design FSD.. - Fuse-rails FSR.. - Fuse-bases SPF - Accessories Signal contact VL0 Signalling of fuse-link state MD-M Disconnecting links ZP.. TMa.. Replacement handles D1PH, DP, DPM - E

4 PHNA FUSE-LINKS WITH BLADE CONTACTS PHNA High limiting and breaking capacity. Low power losses. The fuse-links do not contain harmful substances For use in applications with rated voltage AC 90 V in according to the RoHS Regulation (cadmium, lead and other). lines, cables and other equipment against overload and short-circuit. fuse switch-disconnectors, fuse-rails and fuse-bases. Utilization category gg (black print) for protection of Fuse-links with blade contacts PHNA000 In [A] Order code OEZ:00 OEZ:00 OEZ:00 OEZ:00 OEZ:007 OEZ:008 OEZ:009 OEZ:0 OEZ:011 PHNA000 A gg PHNA000 A gg PHNA000 1A gg PHNA000 0A gg PHNA000 A gg PHNA000 A gg PHNA000 A gg PHNA000 0A gg PHNA000 0A gg Power losses [W] Weight [kg] Package [pcs] Order code OEZ:018 OEZ:019 Power losses [W] Weight [kg] Package [pcs] Order code OEZ:00 OEZ:01 OEZ:0 OEZ:0 OEZ:0 OEZ:0 OEZ:0 Power losses [W] Weight [kg] Package [pcs] Order code OEZ:00 OEZ:007 OEZ:008 OEZ:009 OEZ:0 OEZ:011 OEZ:01 Power losses [W] Weight [kg] Package [pcs] Order code OEZ:08 OEZ:09 OEZ:070 OEZ:071 OEZ:07 Power losses [W] Weight [kg] Package [pcs] Power losses [W] 0 90 Weight [kg] Package [pcs] Fuse-links with blade contacts PHNA00 In [A] 80 0 PHNA00 80A gg PHNA00 0A gg Fuse-links with blade contacts PHNA1 In [A] PHNA1 0A gg PHNA1 A gg PHNA1 80A gg PHNA1 0A gg PHNA1 1A gg PHNA1 A gg PHNA1 00A gg Fuse-links with blade contacts PHNA In [A] PHNA 0A gg PHNA 1A gg PHNA A gg PHNA 00A gg PHNA A gg PHNA 0A gg PHNA 1A gg Fuse-links with blade contacts PHNA In [A] PHNA 0A gg PHNA 1A gg PHNA 0A gg PHNA 00A gg PHNA 00A gg Fuse-links with blade contacts PHNa 1) In [A] ) PHNa 0A gg PHNa 800A gg PHNa 00A gg Order code OEZ:91 OEZ:9 OEZ:9 Fuses PHNa are not manufactured in Cd/Pb free version Accessories Disconnecting links Signal contact Electronic signalling of fuse state Replacement handles E ZP.., TMa.. VL0 MD-M D.. page E8 page E9 page E0 page E

5 PHNA FUSE-LINKS WITH BLADE CONTACTS PHNA Specifications PHNA000 PHNA00 PHNA1 PHNA PHNA PHNa Standards IEC 09 IEC 09 IEC 09 IEC 09 IEC 09 IEC 09 DIN 0 DIN 0 DIN 0 DIN 0 DIN 0 DIN 0 EN 09 EN 09 EN 09 EN 09 EN 09 EN 09 Approval marks Rated operating voltage U n AC 90 V AC 90 V AC 90 V AC 90 V AC 90 V AC 90 V DC 0 V DC 0 V DC 0 V DC 0 V DC 0 V DC 0 V Rated operating current I n 0 A 80 0 A 0 00 A 0 1 A 0 00 A A Breaking capacity AC ka ka ka ka ka 0 ka (RMS) DC 0 ka 0 ka 0 ka 0 ka 0 ka 0 ka Utilization category gg gg gg gg gg gg Fuse-link size 000 (00C) 00 1 a Selectivity 1 : 1. 1 : 1. 1 : 1. 1 : 1. 1 : 1. 1 : 1. E

6 PHNA FUSE-LINKS WITH BLADE CONTACTS PHNA Dimensions Size Dimensions I n [A] a1 a a a b (min) c1 d e1 e f (01) (0) (0) a ± 8. 8± 90± 0 8± 87 0 Characteristics Prearcing time/current characteristic PHNA gg t v [s] A A 1 A 0 A A A A 0 A 0 A A 80 A 0 A U n = AC 90 V U n = DC 0 V / 1 ms I p[a] Prearcing time/current characteristic PHNA1 gg t v [s] A A 1 A 0 A 80 A A 0 A U n = AC 90 V U n = DC 0V / 1 ms I p[a] E

7 PHNA FUSE-LINKS WITH BLADE CONTACTS PHNA Characteristics Prearcing time/current characteristic PHNA gg Prearcing time/current characteristic PHNA gg U n = AC 90 V U n = DC 0V / 1 ms U n = AC 90 V U n = DC 0V / 1 ms t v [s] 1 A 0 A A 00 A A 1 A 0 A t v [s] 00 A 00 A 0 A 1 A 0 A I p[a] I p[a] Prearcing time/current characteristic PHNa gg Cut-off characteristic PHNA gg t v [s] 1 0 A 800 A A U n = AC 90 V U n = DC 0V / 1 ms 1 hr min 0 0 I C [A] U n = AC 90 V 1 0 A 80 A A 0 A 0 A A A A 0 A 1 A A A 0 1 s I [A] p ms I p [A] E

8 PHNA FUSE-LINKS WITH BLADE CONTACTS PHNA Characteristics Cut-off characteristic PHNA1,, gg U n = AC 90 V Cut-off characteristic PHNa gg U n = AC 90 V I C [A] 1 I C [A] 00 A 00 A 0 A 1 A 0 A 00 A A 1 A 0 A 80 A A 0 A A 800 A 0 A I [A] p I p[a] I t t characteristic PHNA000, 00 gg I t t [A s] 0 s -1 s - s - s U n = AC 90 V - s 0 A 80 A A 0 A 0 A A A A 0 A 1 A I t t, I t c values I t I t t I t c 1 ms ms AC 00 V AC 00 V [ A s] [ A s] [ A s] [ A s] PHNA000 A gg 1 0 PHNA000 A gg PHNA000 1A gg PHNA000 0A gg PHNA000 A gg PHNA000 A gg PHNA000 A gg PHNA000 0A gg PHNA000 0A gg PHNA000 A gg PHNA00 80A gg PHNA00 0A gg A A I p[a] E

9 PHNA FUSE-LINKS WITH BLADE CONTACTS PHNA Characteristics I t t characteristic I t t, I t c values PHNA1,, gg I t I t t I t c 1 ms ms AC 00 V AC 90 V U n = AC 90 V [ A s] [ A s] [ A s] [ A s] 9 PHNA1 0A gg PHNA1 A gg PHNA1 80A gg PHNA1 0A gg s PHNA1 1A gg s PHNA1 A gg s PHNA1 00A gg s PHNA 0A gg s PHNA 1A gg PHNA A gg PHNA 00A gg PHNA A gg PHNA 0A gg A PHNA 1A gg A PHNA 0A gg A 1 A PHNA 1A gg A PHNA 0A gg A 00 A PHNA 00A gg A PHNA 00A gg A I t t [A s] 0 A A 0 A I p[a] 80 A I t t characteristic PHNa gg 8 U n = AC 90 V 00 A Correction factor k of I t c dependence on operating voltage (I t c ) f(u) = k x I t c PHNA000, 00, 1,, a PHNa gg 1, I t c [A s] A 0 A k 1,0 0,8 0, I [A] p 0, 0, U [V] E7

10 PNA, PHNA ACCESSORIES FOR PNA, PHNA Disconnecting links They are used wherever it is necessary to disconnect power supply or for various reasons to replace fuse-link (in measuring etc.). They are used in fuse switch-disconnectors, fuse-rails and fuse-bases. I n Order Size Weight Package [A] code [kg] [pcs] ZP000 1) OEZ: , ZP1 OEZ: ZP OEZ: ZP OEZ: ZP/00 OEZ: 0. TMa/A OEZ: a TMa/0A OEZ:1801 a ) Can be used in fuse switch-disconnectors of size 000, 00 and fuse-bases size 00 Specifications ZP.. Standards EN 09-1, -; DIN 0 Approval marks Dimensions Dimensions [mm] A B C D E ZP ZP ZP ZP ZP/ TMa/A TMa/0A E8

11 PNA, PHNA ACCESSORIES FOR PNA, PHNA Signal contact For all types and sizes of fuse-links with blade contacts up to AC 90 V / DC 0 V. Fuse-links are equipped with visual state indicator installed on the upper fuse holder, which can be used as a releasing device for the signal contact VL0 for remote signalling of fuse-link state. Connection is performed by means of sleeves on flat connector wide.8 mm. Order Weight Package code [kg] [pcs] VL0 OEZ: Specifications VL0 Approval marks Rated insulation voltage U i kv Rated current/voltage of contacts A / AC 1 V 0.1 A / DC 0 V Dimensions Diagram State of contacts with installed signal contact VL0 on the fuse-link: fuse not blown contacts C NC closed. C NO NC E9

12 PNA, PHNA ACCESSORIES FOR PNA, PHNA Electronic signalling of fuse state Can be used for fuse-links of all types and sizes. Monitoring of fuse-links state in fuse switch-disconnectors and fuse-bases. Auxiliary contact without power supply contact opened. Auxiliary contact with power supply contact closed. Fuse-link blowing in the circuit contact opened. The devices are designed as modular for mm cutout in the switchboard cover plate. Mounting on U rails according to EN 071 (steel rail recommended). Order Weight Package code [kg] [pcs] MD-M OEZ: Specifications MD-M Standards IEC 0 DIN VDE -1 Approval marks Rated operating voltage U e AC 0 V Rated operating current I e A Rated control voltage U c AC x 1 V Operating range xu c Rated frequency 0 00 Hz Input impedance > Ω/V Maximum permitted backwards power supply 90 % Response/relase time < 0 ms Rated impulse withstand voltage U imp > kv Electrical endurance AC-1 1.x Mechanical endurance > 8 Degree of protection barrel/terminal block IP0/IP0 Number of contacts 1 Connection cross-section solid max. x. mm stranded with end sleeve min. 1x 0. mm Operating ambient temperature C Climatic resistance according to EN /00/0 1) The internal resistance of measuring circuits of the fuse monitor in the MΩ range, therefore when there is fuse missing or it is defective the conditions of contact voltage are still kept (according to EC 97-1, internal resistance > 000 Ω/V).In order to switch off the device the main back-up circuit breaker has to be disconnected. E0

13 PNA, PHNA ACCESSORIES FOR PNA, PHNA Dimensions Diagram L1 L L 1 L1 L L 1 AC1 0 V A L1 L L L1 L L Connection -pole -pole 1- or -pole L1 L L N L L1 L L L L1 L L 1 L1 L L 1 L1 L L 1 F1 F F MD-M F1 F F MD-M F1 MD-M L1` L` L` 1 L1` L` L` 1 L1` L` L` 1 OFF ON K 1) It is possible to check the second fuse-link in the same or different phase at the terminals L-L. ~ M N Application from practice, e.g. automatic disconnection and lock of turning-on of the three-phase motor when there is drop-out of one or several fuse-links. E1

14 PNA, PHNA ACCESSORIES FOR PNA, PHNA Replacement handles Are used for fuse-links handling under voltage but without current. D1PH - it is equipped with insulating end barriers to prevent accidental contact, mainly if barriers are not used between fuse-bases. It is intended for single-pole fuse-bases without end barriers. DP - it is intended for handling fuse-links in both single and three-pole fuse-bases, which are equipped with insulating barriers. DPM - the replacement handle with a protective sleeve to increase the safety of personnel in handling fuse-links. The sleeve is made from beef leather. Order Weight Package code [kg] [pcs] D1PH OEZ: DP OEZ: DPM OEZ: Specifications D1PH DP DPM Standards IEC 09-1, -; IEC 09-1, -; IEC 09-1, -; EN 09-1, - EN 09-1, - Approval marks Rated insulation voltage U i AC V AC V AC V Fuse-link size 000, 00. 1,, 000, 00. 1,, 000, 00. 1,, E

15 PNA, PHNA ACCESSORIES FOR PNA, PHNA Dimensions D1PH DP. max DPM ~0 E

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4 NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

WEG Contactors - CWM and CWME Series

WEG Contactors - CWM and CWME Series Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

RATINGS AND SPECIFICATIONS

RATINGS AND SPECIFICATIONS RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Horizontal distribution busbar HX 3 80/125 A plug-in

Horizontal distribution busbar HX 3 80/125 A plug-in 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety With Separate Actuator 3SE5 Interlock Switches Overview SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Position switches with separate actuator

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

ITEM ESM-BA301

ITEM ESM-BA301 ITEM 085613 ESM-BA301 Description Technical data Accessories Downloads Features ESM-BA.. Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control 3 redundant

More information

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

Residual Current Devices drcm Digital

Residual Current Devices drcm Digital Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

5SL Miniature Circuit Breakers

5SL Miniature Circuit Breakers 5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

Combined RCD/MCB Devices FRBmM, 1+N-pole

Combined RCD/MCB Devices FRBmM, 1+N-pole Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button

More information

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2-PE/S- 24AC-ST Order No.: 2839318 The illustration shows version PT 2-PE/S-230 AC-ST Protective plug PT with surge voltage equipment protection for power supply units,

More information

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A from 0. to 0 A Fuse protection The solution for > Motor protection > Cable and device protection fusib a cat fusib_0_c cat fusib b cat Strong points gg fuse from 0. to A > High level performances > High

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

Solid State Remote Power Controller E

Solid State Remote Power Controller E Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient

More information

Datasheet - SRB 402EM-24V

Datasheet - SRB 402EM-24V Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ Evaluation unit CE-AZ-AE-01B/ CE-AZ-UE-01B 1) 2) 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC Characteristics module XPS-MP - 2 independent functions - 24 V DC Main Range of product Product or component type Safety module name Safety module application 1-Nov-2018 Preventa Safety automation Safety

More information

Modular switch disconnectors and modular change-over switches

Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Characteristics safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Main Range of product Product or component type Safety module name Sep 30, 2018 Preventa Safety automation Configurable

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T Presentation XCR With head for rotary movement operators, spring return to off position (1 contact

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD

More information