TeSys contactors From 115 to 2750 A
|
|
- Tracy Carson
- 5 years ago
- Views:
Transcription
1 Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification, transformers, normal-standby Rated operational current le max. AC- (Ue y 0 V) A 0 A A A A 0 A Ie max. AC- (q y 0 C) 00 A 0 A A A 0 A 00 A Rated operational voltage 000 V 000 V 000 V 000 V 000 V 000 V Number of poles or or or or or or Rated operational power in category AC- 0/0 V 0 kw 0 kw kw kw kw 00 kw 0/00 V kw kw 0 kw 0 kw kw 0 kw V kw 0 kw 00 kw 0 kw 0 kw 0 kw 0 V kw 0 kw 00 kw 0 kw 0 kw 00 kw 00 V kw 0 kw 0 kw kw 0 kw 00 kw 0/0 V 0 kw 00 kw 0 kw kw 0 kw 0 kw Add-on auxiliary contact blocks 000 V kw kw 00 kw 00 kw kw 0 kw Front mounting, identical to those used on LC D contactors (contacts: instantaneous L DNpp, time delay L DT or LA DR, dust and damp protected L DX or DY or DZ) Associated thermal overload relays and controllers Manual-auto Electronic LR F TeSys T Interfaces Specific LA FWB Universal With or without, depending on the control circuit Contactor type LC F LC F0 LC F LC F LC F LC F0 Reversing contactor type LC F LC F0 LC F LC F LC F For customer assembly Pages Contactors / and / / and / Reversing contactors / and / / to / 0 /0 version:.0 00Q-EN.indd
2 00 A 00 A 0 A 0 A 00 A 0 A 000 A 00 A 00 A 00 A 00 A 000 A 00 A 000 A 00 A 00 A 00 A 0 A 000 A 0 A 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V, or, or, or or to to to to 0 kw kw 00 KW 0 kw 0 kw 0 kw 0 kw kw 00 kw 00 kw 0 kw kw 00 kw 0 kw 00 kw 00 kw 0 kw 00 kw 0 kw 0 kw kw kw 0 kw kw 0 kw 00 kw 00 kw 0 kw kw 00 kw kw 0 kw 0 kw 0 kw 00 kw 00 kw kw kw 00 kw 0 kw 0 kw 00 kw 00 kw 00 kw 00 kw 0 kw kw 0 kw kw kw 0 kw 0 kw 0 kw 00 kw kw kw 0 kw 0 kw 0 kw 0 kw 0 kw 0 kw 0 kw Front mounting, identical to those used on LC D contactors (contacts: instantaneous L DNpp, time delay L DT or LA DR, dust and damp protected L DX or DY or DZ) LR F LR F TeSys T TeSys T instantaneous contact compositions: N/C + N/O, N/O + N/C, N/O + N/C or N/O LA FWB With or without, depending on the control circuit LC F00 LC F00 LC F0 LC F0 LC F00 LC F00 LC F00 LC BL LC BM LC BP LC BR For customer assembly / and / / and / / to / / 0 00Q-EN.indd version:.0 /0
3 Characteristics TeSys F contactors ( to 00 A) Control circuit: a.c. or d.c. Environment Contactor type LC F LC F0 LC F Rated insulation voltage (Ui) Conforming to IEC 0-- V Rated impulse withstand voltage (Uimp) Conforming to VDE 00 gr C V Coil not connected to the power circuit kv Conforming to standards EN 0-, EN 0--, IEC 0-, IEC 0--, JEM 0 Product certifications CSA, UL, BV, GL, DNV, RINA, RMROS, LROS, CCC Degree of protection Conforming to IEC 0 IP X front face with shrouds LA F Conforming to VDE 00 Front face protected against direct finger contact with shrouds LA F Protective treatment Standard version TH Ambient air temperature around the device Storage C Operation C - + Permissible at Uc () C Maximum operating altitude Without derating m 000 Operating positions Without derating (not to be used for LC F0, F00 and F00) With derating Not to be used Apply the following derating coefficients: 0. on the pull-in voltage, 0. on the drop-out voltage and 0. on the operationalal current in AC- Apply the following derating coefficients:. on the pull-in voltage,. on the drop-out voltage and 0. on the operational current in AC- In either case: neither the making and breaking capacities nor the electrical and mechanical durabilities can be assured. Shock resistance () / sine wave = ms Vibration resistance () 00 Hz Contactor open gn gn gn Contactor closed gn gn gn Contactor open gn gn gn Contactor closed gn gn gn () In these conditions, it is recommended that LX F coils be used for contactor sizes F to F. () In the least favourable direction, without change of contact state (coil at Uc). Where higher resistance to mechanical shock is required, select shock-proof contactors. Please consult your Regional Sales Office. 0 pages / to / References : pages / and / Dimensions, mounting : pages /0 to / Schemes : page / /0
4 LC F LC F LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F00 LC F EN 0-, EN 0--, IEC 0-, IEC 0--, JEM 0 CSA, UL, BV, GL, DNV, RINA, RMROS, LROS, CCC UL, CSA, GL, UL, CSA, CCC (pending) LROS IP 0 front face with shrouds LA F Front face protected against direct finger contact with shrouds LA F TH (not to be used for LC F0, F00 and F00) Not to be used Apply the following derating coefficients: 0. on the pull-in voltage, 0. on the drop-out voltage and 0. on the operational current in AC-. Apply the following derating coefficients:. on the pull-in voltage,. on the drop-out voltage and 0. on the operational current in AC-. In either case: neither the making and breaking capacities nor the electrical and mechanical durabilities can be assured gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn. gn gn gn. gn gn gn gn gn gn gn gn gn gn. gn gn gn gn 0 /0
5 Characteristics (continued) TeSys F contactors ( to 00 A) Control circuit: a.c. or d.c. Pole characteristics Contactor type LC F LC F0 LC F Number of poles or or or Rated operational current (le)(ue y 0 V) In AC-, q y C A 0 In AC-, q y 0 C A 00 0 Rated operational voltage Up to V (Ue) Frequency limits Of the operational current () Hz / 00 / 00 / 00 Conventional thermal current q y 0 C A 00 0 Rated making capacity Rated breaking capacity Maximum permissible current No current flowing for previous 0 minutes, at q y 0 C Short-circuit protection by fuses U y 0 V I rms conforming to IEC 0-- A Making current: 0 x I in AC- or x I in AC- I rms conforming to A Making and breaking current: x I in AC- or 0 x I in AC- IEC 0-- For 0 s A For 0 s A For min A For min A For 0 min A Motor circuit (type am) A 0 00 With thermal overload relay A (type gg) gg fuses A 00 0 Average impedance per pole At lth and 0 Hz mw Power dissipation per pole for the above operational currents Connection AC- W AC- W Maximum c.s.a. Bar Number of bars Bar mm 0 x x x Cable with lug mm 0 0 Cable with connector mm 0 0 Bolt diameter mm Ø Ø Ø Tightening torque Power circuit connections N.m 0 () Sine wave without interference. Above these values, please consult your Regional Sales Office. () With set of right-angled connectors LA F00 (see page /. () Paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations. 0 pages / to / References : pages / and / Dimensions, mounting : pages /0 to / Schemes : page / /0
6 LC F LC F LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F00 LC F00 or or or, or, or, or or () / 00 / 00 / 00 / 00 / 00 / 00 / 00 / 00 / 00 / () Making current: 0 x I in AC- or x I in AC- Making current:. x I in AC- Making and breaking current: x I in AC- or 0 x I in AC- Making and breaking current:. x I in AC x 00 () 000 x 00 () x 000 () x x 0 x 0 x 0 x 0 x 0 x 00 x 0 x 00 x 00 x 0 0 x 0 x x ( 0 with set of rightangled connectors LA F00) ( with set of right-angled connectors LA F00) 0 /0
7 Characteristics TeSys F contactors ( to 00 A) Control circuit: a.c. Control circuit characteristics with LX or LX coil Contactor type LC F LC F0 LC F Rated control circuit voltage (Uc) 0 or 0 Hz V 000 Control voltage limits (q y C) 0 or 0 Hz coils Operation 0.. Uc Drop-out Uc 0 00 Hz coils Operation Drop-out Average consumption at 0 C and at Uc a 0 Hz Inrush 0 Hz coil VA Hz coil VA Cos j Sealed 0 Hz coil VA 0 00 Hz coil VA Cos j a 0 Hz Inrush 0 Hz coil VA Hz coil VA Cos j Sealed 0 Hz coil VA 0 00 Hz coil VA Cos j Heat dissipation W Operating time () Closing "C" ms 0 Opening "O" ms Mechanical durability at Uc In millions of operating cycles Maximum operating rate at ambient temperature y C Connection Flexible cable without cable end Flexible cable with cable end In operating cycles per hour Min/max c.s.a. or conductors mm / / / conductor mm / / / conductors mm /. /. /. Solid cable or conductors mm / / / without cable end Tightening torque N.m... Mechanical latching Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to / () The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. () Control circuit characteristics with LX coil. 0 pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /0
8 LC F LC F LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F00 LC F () 0 00 () 0.. Uc Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc Uc Uc Uc Uc Uc Uc Uc x x x Min/max c.s.a. / / / / / / / / / / / / / / / / / / / / /. /. /. /. /. /. /. /. /. /. / / / / / / / / / / Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. 0 /
9 Characteristics TeSys F contactors ( to 00 A) Control circuit: d.c. Control circuit characteristics with LX coil Contactor type LC F LC F0 LC F Rated control circuit voltage c V (Uc) Control voltage limits Operation 0.. Uc 0.. Uc 0.. Uc (q y C) Drop-out Uc Uc Uc Average consumption at 0 C and at Uc Average operating time at Uc () c Inrush W Sealed W.. Closing "C" ms Opening "O" ms Note: The arcing time depends on the circuit switched by the poles. For all normal -phase applications, the arcing time is less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. Mechanical durability at Uc In millions of operating cycles Maximum operating rate at ambient temperature y C Cabling Flexible cable without cable end In operating cycles per hour Min/max c.s.a. conductor mm / / / conductors mm / / / Flexible cable conductor mm / / / with cable end conductors mm /. /. /. Solid cable without cable end conductor mm / / / conductors mm / / / Tightening torque N.m... Mechanical latching Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. () The operating times depend on the type of contactor electromagnet and its control mode. The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. 0 pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /
10 LC F LC F LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F00 LC F Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc Uc Uc Uc Uc Uc Uc Uc Uc Uc Uc x x Note: The arcing time depends on the circuit switched by the poles. For all normal -phase applications. the arcing time is less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time Min/max c.s.a. / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /. /. /. /. /. /. /. /. /. /. / / / / / / / / / / / / / / / / / / / / Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. 0 /
11 References TeSys F contactors for motor control in utilisation category AC- ( to 00 A) Control circuit: a.c. or d.c. 00 LC F -pole contactors Standard power ratings of -phase motors 0-0 Hz in category AC- Rated operational current in AC- 0 V 0 V 0 V 0 V 0 V 00 V V 0 V 00 V 0 V 000 V up to Basic reference, to be completed by adding the voltage code () Screw fixing, cabling () Weight kw kw kw kw kw kw kw A kg 0 0 LC Fpp LC F0pp LC Fpp LC Fpp LC Fpp LC F0pp LC F00pp LC F00pp LC F0pp.00 LC F LC F0pp LC F00pp.0 Note: auxiliary contact blocks, modules and accessories: see pages / to /. () Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately, except on contactors LC F0 (see page /). () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). Volts a LC F F 0 Hz (coil LX) B E F FE M P U Q V N 0 Hz (coil LX) E F G L M U Q R 0 00 Hz (coil LX) E F FE G L M P U Q V N R LC F F Hz (coil LX) B E F FE G L M P U Q V N R LC F00 F Hz (coil LX) E F FE G () L M P U Q V N R LC F Hz (coil LX) F FE F L M P U Q V N R LC F Hz (coil LX) () FW FW FW MW MW MW QW QW QW Volts c LC F F0 (coil LX F) BD ED FD GD MD MD UD RD LC F00 F0 (coil LX F) ED FD GD MD UD RD LC F0 (coil LX F) FD GD MD UD RD LC F00 (coil LX F) FW FW MW MW QW () F for LC F0. () Coil LX Fpp + rectifier DRTEpp. 0 pages / to / Characteristics : pages /0 to / Dimensions : pages /0 to / Schemes : page / /
12 References (continued) TeSys F contactors for control in category AC-, (00 to 00 A ) Control circuit: a.c. or d.c. 0, or -pole contactors Maximum current in AC- (q y 0 C) Number of poles Basic reference, to be completed by adding the voltage code () Screw fixing, cabling () Weight A kg 00 LC Fpp.0 LC F LC Fpp.0 0 LC F0pp.0 LC F0pp.0 0 LC Fpp.0 LC Fpp.0 LC Fpp.0 LC Fpp.0 0 LC F00 0 LC Fpp.0 LC Fpp.0 00 LC F0pp.00 LC F0pp LC F00pp.000 LC F00pp.00 LC F00pp 0.00 LC F0 00 LC F00pp.0 LC F00pp.0 LC F00pp LC F0pp.00 LC F0pp.00 LC F0pp.00 0 LC F0ppS0.00 LC F0ppS0.00 LC F00 LC F0ppS LC F0pp.00 LC F0pp LC F LC F00 00 () LC F Note: auxiliary contact blocks, modules and accessories: see pages / to / () Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately (except LC F0, LC F00 and LC F00), see page /. () Standard control circuit voltages, see previous page. () With set of right-angled connectors LA F00 (see page /). 0 pages / to / Characteristics : pages /0 to / Dimensions : pages /0 to / Schemes : page / /
13 Dimensions (continued) TeSys F contactors LC F0 and F00 X X LC a G G supplied min. G max. X (mm) = Minimum electrical clearance according to operating voltage and breaking capacity. J Q Q Voltage V V 00 0 V 000 V F0 P LC F0 0 0 F0, F00 P LC F F0 P () Power terminal protection shroud (see page /). () Minimum distance required for coil removal. LC F0 X X () 0 = 0 = = 0 = () Q 0 0 a 0 Q xmx () 0 0 X (mm) = Minimum electrical clearance according to operating voltage and breaking capacity. Voltage V V () Minimum distance required for coil removal. X (mm) 0 Fixing centres of LC F0 Fixing centres of LC F0 0, 0 xmx = = P=0, P= G 00 () J = 0 = pages / to / Characteristics : pages /0 to / References : pages / to / Schemes : page / /
14 Schemes TeSys F reversing contactors and changeover contactor pairs Reversing contactors for motor control LC F x LC F x LC F Horizontally mounted Vertically mounted L L L /L /L /L L L L U V W /L /L /L Changeover contactor pairs for distribution LC F x LC F x LC F Horizontally mounted Vertically mounted N /L /L /L /L /L /L N /L /L /L N N L L L L L L N /L /L /L N Electrical interlocking of reversers fitted with mechanical interlock without integral electrical contacts LA F KM KM KM KM 0 pages / to / References : pages / to / /
15 Schemes TeSys F contactors Contactors, and -pole contactors LC F to F0 (coil LX F a) LC F to F0 (coil LX F c) LC F to F (coil LX F a) LC F00 (coil LX F a/ c) LC F0 a or c LC F00 a or c LC F00 a or c 0 0 /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ /L T/ Coils Standard a coils LX FF, FG, FJ FL LX FH0 FH0 0 LX FH00 FH0 LX FH0 FH000 LX Fp LX FX Rectifier supplied and fixed on the contactor + Standard c coils LX FF, FG, FH, FJ, FK, FL, FX (), LX Fp () coils in series. Special a coils LX FF, FG LX FHppp LX FJ, FK, FL LX Fp B /B () Breaking on a side. Drop-out time 0 ms. () Breaking on c side. Drop-out time 0 ms. () () pages / to / Characteristics : pages /0 to / References : pages / to / Dimensions : pages /0 to / /
16 Schemes (continued) TeSys F contactors /NC /NO /NO /NC /NC /NO /NC /NC /NO /NC /NC /NO /NC /NC /NO /NO /NC /NO /NO /NO /NC /NO /NO /NC /NO /NC /NC /NC () N/O + N/C LAD N () N/O + N/C () LAD C /NO N/C LAD N0 N/O + N/C LAD N N/O LAD N0 N/O + N/C LAD N /NO N/C LAD N0 N/O LAD N0 /NC () N/O + N/C LAD N () Instantaneous auxiliary contacts N/O LAD N0 () N/C LAD N0 () /NO Add-on blocks /NO /NC /NC /NO /NO /NC /NC /NO /NC /NC /NO /NO /NO /NO /NO /NC /NO /NO /NO /NC /NO /NO /N On-delay N/C + N/O break before make LAD Sp /NC /NO /NO /NO /NO /NO N/O protected (-0 V) + N/O + N/C standard L DZ /NO Off-delay N/O + N/C LAD Rp Time delay auxiliary contacts On-delay N/O + N/C LAD Tp () Items in brackets: See TeSys D contactors. () N/O + N/C make before break. Instantaneous auxiliary contacts with terminal referencing conforming to standard EN 00 (References: pages / and /) N/O + N/C N/O + N/C N/O + N/C N/O + N/C LAD NP LAD NG LAD NP LAD NG Dust and damp protected instantaneous auxiliary contacts N/O (-0 V) N/O (- V) N/O protected (-0 V) + N/O standard L DX0 L DY0 L DZ0 0 pages / to / Characteristics : pages /0 to / References : page / /
TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationControl relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO
Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating
More informationThe technical guide TeSys D
The technical guide TeSys D for power control & protection helping you easily select the right product Catalogue 009 Table of contents TeSys D Contactors TeSys D Contactors Pages Selection guide to Technical
More informationIEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton
K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationK-Line Mini - Contactors, Overload Relays and Accessories
K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................
More informationRM4TA32 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific
More informationXB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC
Characteristics red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC Complementary CAD overall width CAD overall height CAD overall depth Terminals description ISO n 1 Product weight
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationRM4TR31 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationXB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.
Characteristics green complete illuminated selector switch Ø22 2- position stay put 1NO+1NC 24V Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting
More informationK1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More informationMini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)
K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.
More informationZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO
Characteristics light block with body/fixing collar for BA9s bulb 250V 1NO Product availability : Stock - Normally stocked in distribution facility Price* : 55.00 USD Main Range of product Product or component
More informationRE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O
Characteristics industrial timing relay - 0.3..30 s - type A - 24 V AC/DC, 110..240 V AC - 1 C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated
More informationABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm
Characteristics sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Main Range of product Product or component type [Us] rated supply voltage Number of channels 16 Number of terminal
More informationRE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC
Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time
More informationRM4JA31M current measurement relay RM4-J - range ma V AC
Characteristics current measurement relay RM4-J - range 3..1000 ma - 220..240 V AC Complementary [Us] rated supply voltage Operating voltage tolerance Main Range of product Product or component type Relay
More informationTeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size
Selection TeSys contactors For utilisation category AC- Operational current and power conforming to IEC (θ y 0 C) Contactor size Maximum operational current in AC- Rated operational power P (standard motor
More informationRE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC
Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationTeSys protection components
Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationRPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED
Characteristics power plug-in relay - Zelio RPM - 4 C/O - 230 V AC - 15 A - with LED Complementary Shape of pin [Ui] rated insulation voltage Main Range of product Series name Product or component type
More informationRE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O
Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationRM4LA32M liquid level control relay RM4-L V AC
Characteristics liquid level control relay RM4-L - 220..240 V AC Complementary [Un] rated nominal voltage Operating voltage tolerance Width Output contacts Maximum electrode voltage Maximum electrode current
More informationRM4JA01F current measurement relay RM4-J - range ma V AC
Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in
More informationXB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC
Characteristics red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationXACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop
Characteristics pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm
Characteristics sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Main Range of product Product or component type [Us] rated supply voltage Number of channels 16 Number of terminal
More informationRE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz
Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay
More informationXB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V
Product datasheet Characteristics XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V Complementary Product weight Resistance to high pressure washer Colour of
More informationABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type
Product datasheet Characteristics ABR1S102B Complementary Control circuit voltage limits Maximum switching voltage Housing colour Connections - terminals Drop-out voltage Holding current Power dissipation
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More information7 - Control relays. Control relays. b k control relays
/0 Contents 0 - Control relays Control relays b k control relays v For a.c or d.c control circuit................................. page /4 v For d.c control circuit (low consumption).......................
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationRM4JA32MW current measurement relay RM4-J - range A V AC DC
Characteristics current measurement relay RM4-J - range 0.3..15 A - 24..240 V AC DC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in
More informationRE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O
Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range Sep 23,
More informationXB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V
Characteristics green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V Product availability : Stock - Normally stocked in distribution facility Price* : 119.00 USD Main Range of product Product
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationXB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO
Characteristics Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO Product availability : Stock - Normally stocked in distribution facility Price* : 101.00 USD Main Range of product Product
More informationRXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A
Characteristics miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A Complementary [Ui] rated insulation voltage Main Range of product Series name Product or component type Device short name Contacts
More informationATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-9 A - 200..480V - 1.5..4 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Product or component
More informationRE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC
Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 1OC Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationRM4UA33M voltage measurement relay RM4-U - range V V AC
Characteristics voltage measurement relay RM4-U - range 30..500 V - 220..240 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay Power consumption
More informationXCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11
Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11 Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Complementary Assembly style Function available Power supply voltage limits Main Commercial Status Commercialised
More informationZelio Control-modular measurement and control relays 1
Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and
More informationXB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V
Product data sheet Characteristics XB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V Product availability : Stock - Normally stocked in distribution facility Price*
More informationZelio Relay - plug-in relays
Presentation Presentation offer the advantages of compact size and modular design: their slim width ( mm) saves space when mounting on a rail at the back of an enclosure. RSL relays are available in two
More informationXB4BL Main. Device short name. Fixing collar material. Shape of signaling unit head. Contacts type and composition
Product datasheet Characteristics XB4BL73415 Complementary Product weight Resistance to high pressure washer Colour of marking Operator profile Contacts usage Positive opening Operating travel Operating
More information3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...
/ Contents - Selection guide............................................. page / for discrete signals # Electromechanical interface modules........................... page / # Slim electromechanical interface
More informationXCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland
Characteristics limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More informationRSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A
Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A Complementary Shape of pin Main Range of product Series name Product or component type Device short name Contacts type and composition
More informationXCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT
Characteristics limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive
More informationXCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More informationXCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11
Characteristics limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11 Complementary Tracks Switch actuation Electrical connection Contacts insulation form Positive opening Positive opening
More informationXB4BT842 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC
Characteristics Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC Product availability : Stock - Normally stocked in distribution facility Price* : 79.50 USD Main Range of product Product
More informationWEG Contactors - CWM and CWME Series
Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.
More informationXCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13
Characteristics limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More informationRM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA
Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching
More informationFor hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T
For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T Presentation XCR With head for rotary movement operators, spring return to off position (1 contact
More informationXCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device
More informationXCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT
Characteristics limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening
More informationTeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters
Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp
More informationABS2EC01EB input interface module mm - solid state - 24 V DC
Characteristics input interface module - 9.5 mm - solid state - 24 V DC Complementary Control voltage limits Voltage state 1 guaranteed Current state 1 guaranteed Voltage state 0 guaranteed Current state
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationZB5FG09 flush mounted selector switch head key pos stay put
Characteristics flush mounted selector switch head key 455 3 pos stay put Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKJ Sensor
More informationXB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC
Characteristics Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC Main Range of product Product or component type Device short name Mounting diameter Sep 4, 2018 Harmony XB7 Emergency
More informationRM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC
Characteristics phase control relay RM17-T - range 183..484 V AC Complementary Maximum switching voltage Minimum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage
More informationOsiSwitch Limit Switches Innovation through modularity
OsiSwitch Limit Switches Innovation through modularity Osiswitch limit switches Simply Smart: Variable composition Note: All outline dimensions are in mm/inches Positive openings with rigid operators and
More informationXB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"
Characteristics PB - Spring Rtn, red - 1NC -White "STOP" Main Range of product Product or component type Device short name Mounting diameter Sep 4, 2018 Harmony XB7 Push-button XB7 Sale per indivisible
More informationXCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT
Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device
More informationXCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device
More informationXCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT
Characteristics limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening Positive opening
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width
More informationSR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display
Characteristics compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display Main Range of product Product or component type Zelio Logic Compact smart relay Complementary Local display Number or
More informationATS01N232RT soft starter for asynchronous motor - ATS01-32 A V
Characteristics soft starter for asynchronous motor - ATS01-32 A - 460..480 V Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 01 Product or component
More informationRPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED
Characteristics power plug-in relay - Zelio RPM - 1 C/O - 120 V AC - 15 A - with LED Stock Code: Non-Stock - Not normally stocked in distribution facility Price*: 5.00 USD Complementary Shape of pin [Ui]
More informationXCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx
Characteristics limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Main Range of product Series name Product or component type Device short name Sensor design Body type Head type Material Fixing
More informationTeSys SK, K, D. Technical Data for Designers. Contents
Control relays TeSys SK, K, D Tehnial Data for Designers Contents TeSys SK: > harateristis...b/ and B/1 > dimensions...b/1 > shemes...b/1 TeSys K: > harateristis...b/18 and B/19 > dimensions...b/0 > shemes...b/1
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationRE9RA21MW7 off-delay timing relay s V AC -
Characteristics off-delay timing relay - 3..300 s - 240 V AC - solid state Main Range of product Product or component type Discrete output type Component name Time delay type Time delay range [Us] rated
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)
Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationTM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS
Characteristics SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Main Range of product Product or component type Device short name Safety module application Function of module Jun 29, 2018
More informationRM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC
Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationTM3SAF. Main. Device short name
Product datasheet Characteristics TM3SAF5R SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS Complementary Main Range of product Product or component type Device short name Safety module application
More informationATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)
Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationSR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display
Characteristics modular smart relay Zelio Logic - 26 I O - 100..240 V AC - clock - display Main Range of product Product or component type Zelio Logic Modular smart relay Complementary Local display Number
More informationSR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display
Characteristics modular smart relay Zelio Logic - 26 I O - 100..240 V AC - clock - display Main Range of product Product or component type Zelio Logic Modular smart relay Complementary Local display Number
More information