R410A D2D_AU019E/

Size: px
Start display at page:

Download "R410A D2D_AU019E/"

Transcription

1 R41A 2. : AUU18RCLX AUU24RCLX D2D_AU19E/

2 2-1. FEATURE MODELS : AUU18RCLX / AOU18RLX AUU24RCLX / AOU24RLX FEATURES Easy maintenance The control box is easily accessible for maintenance work Wide opening for easy access. Detachable,washable filter and intake grille. Wide opening and long-life filter. Long-life filter High efficiency, long-life filter extends the cleaning cycle. Long-life filter Slim intake grille Slim type intake grille can fit the ceiling after installation. 25/2 (2) unit: in.(mm) Group controller One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings. Connectable quantity : Maximum 16 indoor units for 1 remote controller. - (2-1) -

3 - (2-2) - Duct connection hole opening Fresh air can be introduced through this opening. Distribution duct Fresh air Distribution duct Conditioned air can be distributed by means of a distribution duct. One-way Two-way

4 - (2 - ) REMOTE CONTROLLER WIRED REMOTE CONTROLLER FEATURES 7 SU MO TU WE TH FR SA AM F Various timer setup (ON / OFF / WEEKLY) are possible. Equipped with weekly timer as standard function. (2 times Start / Stop per day for a week) When setting up a timer, operation mode and a temperature setup can be changed. When a failure occurs,the error code is displayed. (Maximum of 16) Error indication.(a maximum of 16 error histories are memorizable.) Easy installation with a slim shape with no boldge in the back. Built in room temperature sensor. High performance and compact size Three functions are combined in one unit. Wired remote controller Weekly timer Setback timer Built-in timers Weekly timer Possible to set ON/OFF time to operate twice each day of the week. SU MO TU WE TH FR SA Easy-to-understand time bar display Setback timer Possible to set temperature for two time spans and for each day of the week. SU MO TU WE TH FR SA 7 PM Setup screen example [Set to Wednesday: AM8: to PM8:,75 F(24 C)] 75 F (24 C) 7 SU MO TU WE TH FR SA AM F Screen after setup PM Setup screen example [Set from Sunday to Saturday: PM12: to PM:, 82 F(28 C)] 82 F (28 C) F time O'clock time O'clock AM PM AM PM At "Weekly timer" + "Set back timer" setup 82 F (28 C) 75 F (24 C) 75 F 82 F 75 F (24 C 28 C 24 C) time AM PM O'clock Easy-to-understand operation Timer area Operation area Simple installation Components are compatible with standard switch boxes. Flat back construction allows equipment to be installed wherever it is needed. [ Variable timer control ] The operation/display sections are zoned according to time and operation, enabling variable programming to match application. European switch box JIS box

5 - (2-4) - FUNCTIONS 1 START/STOP button Pressed to start and stop operation. Display DAY CLOCK ADJUST 8 DAY OFF ENERGY THERMO 4 SET BACK SAVE SENSOR 9 6 DELETE SET Display panel SU MO TU WE TH FR SA AM PM SU MO TU WE TH FR SA AM PM F 22 2 F Set Temperature button Selects the setting temperature. 5 Energy save button Turns the energy efficient mode on and off Master control button Selects the operating mode(auto, HEAT, FAN, COOL, DRY). Fan control button Selects the fan speed (AUTO, LOW, MED, HIGH). Thermo sensor button Selects whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller. Timer mode (CLOCK ADJUST) button Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER) Set the current time. Day (DAY OFF) button Temporarily cancels of one day timer. Set back button pressed select the set back timer. Set time button Pessed to select the set back timer. Delete button The schedule of a weekly timer is deleted. Set button Sets the date, hour, minute and on-off time. Vertical air flow direction and swing button Push for two seconds to change the swing mode Operation lamp Lights during operation and when the timer is on. Timer and clock display Operation mode display Fan speed display Central control display Temperature display Stand by display Indicates during defrosting operation. Vertical swing display 22 Energy save display 2 Thermo sensor display SPECIFICATION SIZE [H x W x D in. (mm)] 4-2/2 x 4-2/2 x 4/64 (12 x 12 x 17) WEIGHT oz. (g) 5-21/5 (16) CABLE LENGTH ft.( m ) (1) POWER ( V ) 12

6 - (2-5) SPECIFICATIONS MODEL NAME POWER SOURCE AVAILABLE VOLTAGE RANGE CAPACITY AUU18RCLX AOU18RLX AUU24RCLX AOU24RLX kw 5.2 / / 8. BTU/h 17,8 / 21,5 22,2 / 27, kw 6.15 / / 8.5 BTU/h 21, / 25,6 24,2 / 29, COOLING RATED/MAX 1.61 / / 2.88 INPUT POWER kw HEATING RATED/MAX 2.5 / / 2.88 CURRENT COOLING RATED/MAX 7. / / 12.5 A HEATING RATED/MAX 8.9 / / 12.5 A SEER COOLING HSPF HEATING COMPRESSOR OUTPUT REFRIGERANT REFRIGERANT OIL DRAIN PIPE COOLING HEATING STARTING CURRENT MOISTURE REMOVAL AIR CIRCULATION COOL/HEAT FAN SPEED COOL/HEAT FAN TYPE x Q'ty INDOOR OUTDOOR INDOOR FAN MOTOR OUTPUT NOISE LEVEL (SOUND PRESSURE) COOL/HEAT HEAT EXCHANGER TYPE CASING COLOR DIMENSIONS H W D WEIGHT PIPE OUTDOOR INDOOR OUTDOOR TYPE INDOOR OUTDOOR INDOOR OUTDOOR INDOOR OUTDOOR INDOOR OUTDOOR SIZE TYPE STARTING METHOD INDOOR OUTDOOR Coil Fin pints/h( l/h ) 5. (2.5) 6.4 (.) High 559 / 495 (95 / 84) 618 / 548 (15 / 9) Med 477 / 424 (81 / 72) 56 / 465 (91 / 79) Low 94 / 65 (67 / 62) 45 / 95 (74 / 67) CFM(m /h) Quiet - - High 1942 / 1942 ( / ) 2119 / 227 (6 / 8) Low - - High 45 / 4 49 / 44 Med 9 / 5 4 / 8 Low / 1 6 / r.p.m Quiet - - High 78 / / 9 Low - - INDOOR OUTDOOR INDOOR OUTDOOR High 42. / / 4. Med 9. / / 9. db(a) Low 6. / / 5. Rows x Stages Fin Pitch Coil Dimensions Coil Fin Rows x Stages Fin Pitch Coil Dimensions INDOOR OUTDOOR GROSS CONNECTION METHOD SIZE MAX LENGTH MAX HEIGHT OPERATION(OUTDOOR) REMOTE CONTROLLER TYPE MATERIAL NET GROSS NET W FPI in. (mm) FPI in. (mm) 51. / / 55. LIQUID 1/4 (6.5) /8 (9.52) in. (mm) GAS 1/2 (12.7) 5/8 (15.88) TYPE CHARGE TYPE RATED/MAX RATED/MAX COOLING HEATING INDOOR OUTDOOR W in. (mm) lb. (Kg) ft. (m) ft. (m) lb. oz. (g) F ( C) mm (Reference in.) CASSETTE MODELS INVERTER HEAT PUMP 28/2V 6Hz V 6Hz TURBO 1 PROPELLER DC TWIN ROTARY (INVERTER) 1 Inverter Copper tube Aluminium /2 8 - /16 1-1/16 ( ) [ 2 pieces] Copper tube Aluminium /2 5-7/16 1-7/16 ( ) White (5Y9/.5NN) Beige (1YR7.5/1.NN) 9-11/ / /16 ( ) 2-11/16 5-7/16 1 (8 9 ) 1-1/2 41-2/2 4-11/2 ( ) 8 - / / /2 ( ) 75 (4) 141 (64) 97 (44) 154 (7) FLARE 164 (5) [chargeless:49 (15)] 66 (2) R41A 4lb. oz. (19) POE to 115 (-18 to 46) 14 to 75 (-1 to 24) WIRED ABS Outer diameter 7. (1-15/2) Inner diameter 2. (1-1/4) Note: Specifications are based on the following conditions. Power source of specifications : 2V Cooling:Indoor temperature of 8.6 F (27 C)DB / 66.2 F(19 C)WB,and outdoor temperature of 95. F (5 C)DB/75.2 F (24 C)WB. Heating:Indoor temperature of 68. F (2 C)DB / 59. F (15 C)WB,and outdoor temperature of 44.6 F (7 C)DB/42.8 F (6 C)WB. Pipe length : 24ft. 7in.(7.5m),Height difference : ft.(m) [Outdoor unit - Indoor unit]

7 - (2-6) DIMENSIONS OUTDOOR UNIT MODELS : AOU18R, AOU24R Unit : in.(mm) Top view 5-7/16 (9) -1/2 (77) 1-7/2 (1) 1 () 15/2 (12) 11/2 (9) 25-19/2 (65) Air flow MOUNTING POSITION When there are obstacles at the back or front sides. When there are obstacles at the back, side(s), and top. When there are obstacles at the back, side with the installation of more than one unit. 2-5/8 (6) or more 14-7/8 (7) -29/2 (99) 7-2/2 (196) 1/16 (21) 2-11/16 (8) Front view 15-/4 (4) Side view Bottom view 6-11/16 (17) 5-25/2 (147) 2-5/8 (6) or more -15/16 (1) or more -15/16 (1) or more 9-27/2 (25) or more (Service space) 11-1/16 () or more 9-27/2 (25) or more 9-27/2 (25) or more 11-1/16 () or more

8 - (2-7) INDOOR UNIT MODELS : AUU18R, AUU24R Unit : in.(mm) 1-/16 () Side view 9-11/16 (246) 7 (94) 29-17/2 (75) 2-11/16 (8) 7 (94) Bottom view (Panel) 29-17/2 (75) 2-11/16 (8) Bottom view 9-1/4 (25) Drain inside Dia. 2mm outside Dia. 7mm 7-7/8 (2) 2-/8 (6) (Drain pipe) 12 (5.5) 11-/4 (298.5) 9-25/2 (248.5) 2-/4 (7) (Large pipe) -15/16 (1) (Small pipe) Side view (Standard setting) Side view (Slender setting)

9 - (2-8) - MOUNTING POSITION Unit : in.(mm) Strong and durable ceiling 96 (2,4) or more 47-1/4 (1,2) or more Obstruction Floor 9-/8 (1,) or more You can select 2-way setting (A) Standard setting (B) Slender setting 9-27/2 (25) or more 8-15/2 (215) or more -15/16 (1) or more -15/16 (1) or more -15/16 (1) or more (4 directions) ( directions) Piping position (2 directions) (2 directions) -15/16 (1) or more

10 - (2-9) REFRIGERANT CIRCUIT MODELS : AUU18R / AOU18R OUTDOOR UNIT INDOOR UNIT Pressure Check Valve High Pressure Switch Refrigerant Pipe 1/2 (12.7mm ) Charging Valve Condenser Muffler 4-way Valve Evaporator Accumulator c Compressor Expansion Valve Refrigerant Pipe 1/4 (6.5mm ) Strainer Strainer Charging Valve : COOL : HEAT MODELS : AUU24R / AOU24R OUTDOOR UNIT INDOOR UNIT Pressure Check Valve Refrigerant Pipe 5/8 (15.88mm ) High Pressure Switch Charging Valve Condenser Muffler 4-way Valve Evaporator Accumulator c Compressor Expansion Valve Refrigerant Pipe /8 (9.52mm ) Strainer Strainer Charging Valve : COOL : HEAT c (COMPRESSOR TEMP.)

11 - (2-1) WIRING DIAGRAMS OUTDOOR UNIT MODELS : AOU18R, AOU24R TEMP. TEMP. TEMP. TEMP. TEMP. G G TO INDOOR UNIT TO POWER SUPPLY

12 - (2-11) INDOOR UNIT MODELS : AUU18R, AUU24R G (N)

13 - (2-12) CAPACITY TABLE MODELS : AUU18R / AOU18R COOLING AFR 559 Indoor temperature 64 FDB 7 FDB 75 FDB 8 FDB 85 FDB 9 FDB 54 FWB 6 FWB 6 FWB 67 FWB 71 FWB 7 FWB ( FDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Outdoor temperature AFR: Air flow rate(cfm) TC : Total capacity (kbtu) SHC: Sensible Heat capacity (kbtu) PI : Power Input (kw) AFR 15.8 Indoor temperature CDB CDB 2.89 CDB CDB CDB 2.22 CDB CWB CWB CWB CWB CWB CWB ( CDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Outdoor temperature AFR: Air flow rate(m /min) TC : Total capacity (kw) SHC: Sensible Heat capacity (kw) PI : Power Input (kw)

14 - (2-1) - HEATING AFR 494 Indoor temperature 6 FDB 65 FDB 7 FDB 75 FDB 78 FDB Outdoor temperature ( FDB) ( FWB) TC PI TC PI TC PI TC PI TC PI AFR: Air flow rate(cfm) TC : Total capacity (kbtu) PI : Power Input (kw) AFR 14. Outdoor temperature Indoor temperature CDB 18. CDB CDB 2.89 CDB CDB ( CDB) ( CWB) TC PI TC PI TC PI TC PI TC PI AFR: Air flow rate(m /min) TC : Total capacity (kw) PI : Power Input (kw)

15 - (2-14) - MODELS : AUU24R / AOU24R COOLING AFR 618 Indoor temperature 64 FDB 7 FDB 75 FDB 8 FDB 85 FDB 9 FDB 54 FWB 6 FWB 6 FWB 67 FWB 71 FWB 7 FWB ( FDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Outdoor temperature AFR: Air flow rate(cfm) TC : Total capacity (kbtu) SHC: Sensible Heat capacity (kbtu) PI : Power Input (kw) AFR 17.5 Indoor temperature CDB CDB 2.89 CDB CDB CDB 2.22 CDB CWB CWB CWB CWB CWB CWB ( CDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Outdoor temperature AFR: Air flow rate(m /min) TC : Total capacity (kw) SHC: Sensible Heat capacity (kw) PI : Power Input (kw)

16 - (2-15) - HEATING AFR 547 Indoor temperature 6 FDB 65 FDB 7 FDB 75 FDB 78 FDB Outdoor temperature ( FDB) ( FWB) TC PI TC PI TC PI TC PI TC PI AFR: Air flow rate(cfm) TC : Total capacity (kbtu) PI : Power Input (kw) AFR 15.5 Outdoor temperature Indoor temperature CDB 18. CDB CDB 2.89 CDB CDB ( CDB) ( CWB) TC PI TC PI TC PI TC PI TC PI AFR: Air flow rate(m /min) TC : Total capacity (kw) PI : Power Input (kw)

17 - (2-16) CAPACITY COMPENSATION FOR PIPE LENGTH AND HEIGHT DIFFERENCE MODELS : AUU18R / AOU18R HEIGHT DIFFERENCE Outdoor unit is bottom-side Outdoor unit is up-side COOLING PIPE LENGTH 5 m 7.5 m 15 m 2 m m 4 m 5 m 16 ft. 25 ft. 49 ft. 66 ft. 98 ft. 11 ft. 164 ft. 2m 66ft m ft m 25ft m 16ft m ft m -16ft m -25ft m -ft m -66ft PIPE LENGTH HEATING 5 m 7.5 m 15 m 2 m m 4 m 5 m 16 ft. 25 ft. 49 ft. 66 ft. 98 ft. 11 ft. 164 ft. HEIGHT DIFFERENCE Outdoor unit is bottom-side Outdoor unit is up-side 2m 66ft m ft m 25ft m 16ft m ft m -16ft m -25ft m -ft m -66ft

18 - (2-17) - MODELS : AUU24R / AOU24R PIPE LENGTH HEIGHT DIFFERENCE Outdoor unit is bottom-side Outdoor unit is up-side COOLING 5 m 7.5 m 15 m 2 m m 4 m 5 m 16 ft. 25 ft. 49 ft. 66 ft. 98 ft. 11 ft. 164 ft. 2m 66ft m ft m 25ft m 16ft m ft m -16ft m -25ft m -ft m -66ft PIPE LENGTH HEATING 5 m 7.5 m 15 m 2 m m 4 m 5 m 16 ft. 25 ft. 49 ft. 66 ft. 98 ft. 11 ft. 164 ft. HEIGHT DIFFERENCE Outdoor unit is bottom-side Outdoor unit is up-side 2m 66ft m ft m 25ft m 16ft m ft m -16ft m -25ft m -ft m -66ft

19 - (2-18) ADDITIONAL CHARGE CALCULATION MODELS : AUU18R / AOU18R REFRIGERANT TYPE REFRIGERANT AMOUNT lb. oz. (g) REFRIGERANT CHARGE R41A 4 lb. oz. (19) PIPE LENGTH ADDITIONAL CHARGE ft (MAX) m (MAX) lb. oz. (Chargeless).7 oz. 1.8 oz. 1 lb. 2.1 oz. 1 lb. 9. oz. g (Chargeless) oz./ft. (2g/m) MODELS : AUU24R / AOU24R REFRIGERANT TYPE R41A REFRIGERANT AMOUNT lb. oz. (g) 4 lb. oz. (19) REFRIGERANT CHARGE PIPE LENGTH ADDITIONAL CHARGE ft (MAX) m (MAX) lb. oz. (Chargeless) 7. oz. 1 lb. 5.1 oz. 2 lb.. oz. lb. 1.5 oz. g (Chargeless) oz./ft. (4g/m)

20 - (2-19) OPERATION RANGE Model Operation Range Mode Indoor unit Outdoor unit Indoor temperature Indoor humidity Outdoor temperature AUU18R AUU24R AOU18R AOU24R Cooling Dry Heating 64 to 88 F (18 to 1 C) 6 to 88 F (16 to 1 C) About 8% or less - to 115 F (-18 to 46 C) 14 to 75 F (-1 to 24 C)

21 - (2-2) FAN PERFORMANCE AND AIR FLOW AIR VELOCITY DISTRIBUTION MODEL : AUU18R 4-WAY AIR OUTLET (ft.)(m) (.5) (1) 7(2) 1/16(.25) 2(.5) (1) 7(2) 7(2) (1) 2(.5) 1/16(.25) 7(2) 1/16(.25) UNIT : ft./s(m/s) Note : Condition Fan speed : High Operation mode :FAN (1) 2(.5) 1/16(.25) (ft.)(m) UNIT : ft./s(m/s) /16(.25) UNIT : ft./s(m/s) (ft.)(m) 7(2) 7(2) (1) (1) 2(.5) 2(.5) 1/16(.25) TOP VIEW HORIZONTAL LOUVER : Upward (m) (ft.) SIDE VIEW HORIZONTAL LOUVER : Upward (m) (ft.) 7 2 7(2) (1) 7(2) (1) 1 2(.5) 1/16(.25) 2(.5) 1/16(.25) SIDE VIEW HORIZONTAL LOUVER : Downward (m) (ft.) 2-WAY AIR OUTLET (ft.)(m) 1 1 1/16(.25) 2(.5) (1) 7(2) 7(2) (1) 2(.5) UNIT : ft./s(m/s) 1/16(.25) TOP VIEW HORIZONTAL LOUVER : Upward (m) (ft.) UNIT : ft./s(m/s) (ft.)(m) (2) 7(2) (1) (1) 1/16(.25) 1/16(.25) 2(.5) 2(.5) SIDE VIEW HORIZONTAL LOUVER : Downward (m) (ft.)

22 - (2-21) - MODEL : AUU24R 4-WAY AIR OUTLET (ft.)(m) (.5) (1) 1/16(.25) UNIT : ft./s(m/s) Note : Condition Fan speed : High Operation mode :FAN 1 7(2) 1 1/16(.25) 2(.5) (1) 7(2) 7(2) (1) 2(.5) 1/16(.25) 7(2) 7 2 (1) 1/16(.25) 2(.5) (ft.)(m) 1 UNIT : ft./s(m/s) TOP VIEW HORIZONTAL LOUVER : Upward (m) (ft.) (2) 7(2) (1) (1) 2(.5) 2(.5) 1/16(.25) 1/16(.25) SIDE VIEW HORIZONTAL LOUVER : Upward (m) (ft.) (ft.)(m) /16(.25) 2(.5) 7(2) (1) UNIT : ft./s(m/s) 7(2) (1) 2(.5) 1/16(.25) SIDE VIEW HORIZONTAL LOUVER : Downward (m) (ft.) 2-WAY AIR OUTLET (ft.)(m) 1 1 1/16(.25) 2(..5) (1) 7(2) 7(2) (1) 2(.5) UNIT : ft./s(m/s) 1/16(.25) TOP VIEW HORIZONTAL LOUVER : Upward (m) (ft.) UNIT : ft./s(m/s) (ft.)(m) (2) 7(2) 1/16(.25) (1) (1) 1/16(.25) 2(.5) 2(.5) SIDE VIEW HORIZONTAL LOUVER : Upward (m) (ft.)

23 - (2-22) AIR FLOW MODELS : AUU18R / AOU18R FAN SPEED NUMBER OF ROTATIONS (r.p.m) HIGH 45 AIR FLOW m /h 95 l/s 264 CFM 559 m /h 81 Indoor unit MED 9 l/s 225 CFM 477 m /h 67 LOW l/s 186 CFM 94 m /h Outdoor unit HIGH 78 l/s 917 CFM 1942 MODELS : AUU24R / AOU24R FAN SPEED NUMBER OF ROTATIONS (r.p.m) AIR FLOW m /h 15 HIGH 49 l/s 292 CFM 618 m /h 91 Indoor unit MED 4 l/s 25 CFM 56 m /h 74 LOW 6 l/s 26 CFM 45 m /h 6 Outdoor unit HIGH 85 l/s 1 CFM 2119

24 - (2-2) DUCT CONNECTION MODELS : AUU18R, AUU24R OUTLET AIR Duct [(Inside Dia. -15/16"(1mm)] L L DUCT STATIC PRESSURE DUCT STATIC PRESSURE Duct [(Inside Dia. -15/16"(1mm)] in.wg (Pa) in.wg (Pa) *(1) *(2) *() *(1) *(2) (mmaq) in.ag 1 1/ /16 1/4 5/2 /2 (m /min) ft. /min (mmaq) in.ag 1 1/2 *() /16 1/4 5/2 / *(1) L=16' 4-27/2" (5m) *(2) L=9' 1-1/8" (m) *() L=' -/8" (1m) (m /min) ft. /min FRESH AIR Duct [(Inside Dia. 2-/4"(7mm)] in.wg (Pa) (mmaq) in.ag 7 6 1/4 P Duct Fan Static pressure required to take in fresh air DUCT STATIC PRESSURE /2 /2 (m /min) ft. /min

25 - (2-24) NOISE LEVEL CURVE OUTDOOR UNIT COOLING MODEL : AOU18R 8 7 MODEL : AOU24R 8 7 NC-65 NC-65 Octave band sound pressure level, db:(db=.2µbar) NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 Octave band sound pressure level, db:(db=.2µbar) NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC , 2, 4, 8, Octave band center frequency,hz , 2, 4, 8, Octave band center frequency,hz HEATING MODEL : AOU18R 8 MODEL : AOU24R NC-65 NC-65 Octave band sound pressure level, db:(db=.2µbar) NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 Octave band sound pressure level, db:(db=.2µbar) NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC , 2, 4, 8, , 2, 4, 8, Octave band center frequency,hz Octave band center frequency,hz

26 - (2-25) - SOUND LEVEL CHECK POINT ft. -/8in. (1m)

27 - (2-26) INDOOR UNIT COOLING MODEL : AUU18R 8 7 MODEL : AUU24R 8 7 NC-65 NC-65 Octave band sound pressure level, db:(db=.2µbar) LOW HIGH NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 Octave band sound pressure level, db:(db=.2µbar) LOW HIGH NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC , 2, 4, 8, Octave band center frequency,hz , 2, 4, 8, Octave band center frequency,hz HEATING MODEL : AUU18R 8 MODEL : AUU24R NC-65 NC-65 Octave band sound pressure level, db:(db=.2µbar) LOW HIGH NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 Octave band sound pressure level, db:(db=.2µbar) LOW HIGH NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC , 2, 4, 8, , 2, 4, 8, Octave band center frequency,hz Octave band center frequency,hz

28 - (2-27) - SOUND LEVEL CHECK POINT CENTER // // MIC 4ft. 11-1/16in.(1.5m) MIC // // CENTER

29 - (2-28) ELECTRIC CHARACTERISTICS MODELS : AUU18R / AOU18R, AUU24R / AOU24R Model Name Power Supply Rated Value Indoor unit Outdoor unit Voltage Frequency V Hz Cooling Heating Cooling Heating Current A Input kw Max Operating Current A Starting Current *1) Wiring Spec. Indoor Fan Motor Outdoor Fan Motor Mode Main Fuse (Circuit breaker) Current Power Cable *2)Limited wiring length Input Full Load Amp. Input Full Load Amp. A A AWG ft. kw A kw A AUU18R AOU18R AUU24R AOU24R *1) Wiring Spec. : Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E5) *2) Limited Wiring length : This is the wiring length in case voltage descent is less than 2%. When the wiring length becomes long, please select the wiring of a more larger diameter.

30 - (2-29) SAFETY DEVICE OUTDOOR UNIT FUSE ON MAIN PCB PROTECTION FORM FAN MOTOR PROTECTION THERMAL PROTECTOR F C COMPRESSOR PROTECTION HIGH PRESSURE PROTECTION CURRENT FUSE THERMAL PROTECTOR PRESSURE SWITCH AOU18R, AOU24R OFF 257 F ON 176 F OFF:69±15 PSI ON:464±22 PSI.15A 25V 5A 25V OFF 125 C ON 8 C OFF:4.2±.1MPa ON:.2±.15MPa INDOOR UNIT PROTECTION FORM AUU18R, AUU24R PCB FUSE CURRENT FUSE.15A 25V FAN MOTOR PROTECTION THERMAL PROTECTOR 2±9 F OFF 15±5 C OFF

31 - (2 - ) FUNCTION SETTING INDOOR UNIT INDOOR UNIT DIP SW SW Auto restart validity/invalidity Room temperature correct coefficient Room temperature correct coefficient Forbidden SW 4 2 Ceiling height setting Rotary SW SW 2 Indoor unit number setting JM1 Forbidden Jumper Wire JM2 Forbidden JM Forbidden SWITCH POSITION Indoor unit control circuit board

32 - (2-1) SWITCH FUNCTION (INDOOR UNIT) DIP SWITCH SETTING SW1-1. Auto restart setting Auto restart function can be selected by turning this switch ON/OFF. AUTO RESTART SETTING SW 1-1 OFF ON ( Factory setting) SW state Invalidity Validity SW1-2, 1-. Room temperature correct coefficient of heating. Decide the heating temperature correct coefficient value of heating. TEMPERATURE CORRECTION ( Factory setting) SW 1-2 SW 1- SW state heating dry cooling OFF OFF +.6degF -.6degF -.6degF ON OFF -.6degF -.6degF -.6degF OFF ON degf degf degf ON ON +7.2degF degf degf SW4-1. Dip SW 4-1setting forbidden SW 4-1 OFF ( Factory setting) SW4-2, 4-. Ceiling height setting Ceiling height ft. (m) 8ft. 2-7/16in. to 9ft. 1-1/8in. (2.5 to.) 9ft. 1-1/8in. to 11ft. 5-25/2in. (. to.5) More than 11ft. 5-25/2in. (.5) Less than 8ft. 2-7/16in. (2.5) ( Factory setting) DIP - SW4 Normal 1-2 OFF OFF High ceiling 1 - ON OFF High ceiling 2 - OFF ON Low ceiling - ON ON If the setting for a low ceiling is selected, the capacity of the air conditioner decreases slightly.

33 - (2-2) - ROTARY SWITCH SETTING (SW2) This switch can be used when group control system. Set the indoor unit address in the,1,-,15 order. ( Factory setting) SW 2 SW state Single 1-15 Indoor unit address JUMPER WIRE SETTING JM 1, 2, setting forbidden JM 1, 2, Connect Disconnect ( Factory setting) SW state Forbidden

34 - (2 - ) WIRED REMOTE CONTROLLER CIRCUIT BOARD DIP SW Wired remote controller Dual remote controller setting Group control setting Model setting 5 Auto changeover setting 6 Memory backup setting SWITCH POSITION Wired remote controller Front case (back side) OFF ON DIP Switch ON

35 - (2-4) WIRED REMOTE CONTROLLER DIP SWITCH SETTING 1. SW setting 1-1 Dual remote controller setting Set the remote controller DIP switch No.1 and 2 according to the following table. Number of remote controller Master unit DIP-SW No.1 ( Factory setting) DIP-SW No.2 Slave unit DIP-SW No.1 DIP-SW No.2 1 (Normal) ON OFF 2 (Dual) OFF OFF ON ON 1-2 Group control setting Number of indoor unit connection (One/Multiple) This is switched according to the number of connected indoor units. ( Factory setting) DIP-SW No. OFF ON Number of indoor unit One unit connection Multiple unit connection 1- Model setting The system type of the outdoor unit can be selected by setting up DIP switch No.4 as follows. ( Factory setting) DIP-SW No.4 OFF ON Model Heat Pump model Cooling only model 1-4 Auto changeover setting Selecting auto changeover validity / invalidity. DIP-SW No.5 OFF ON ( Factory setting) Auto changeover Invalidity Validity 1-5 Memory backup setting Set to ON to use batteries for the memory backup.if batteries are not used, all of the settings stored in memory will be deleted if there is a power failure. This function is wired remotecontroll only. DIP-SW No.6 OFF ON ( Factory setting) Memory backup Invalidity Validity

36 - (2-5) OPTIONAL PARTS ADDITIONAL GRILLE UTG-AGEA-W The additional grille hides the gap between the ceiling hole and the outlet grille. Additional grille (optional parts) Additonal grille The ceiling hole Indoor Unit(grille)

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change

More information

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A, SINGLE Technical Data Book 4Way Cassette S for (Inv, R410A, 1 Ver.1.0 Release Single 4Way Cassette S for USA (Inv, R410A, 60Hz, HP) TDB 15.02.05 - Ver.1. 5.0.09 Ver.1..0.0 Ver.1..0. Index 1 Nomenclature

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book Wind-Free 4Way Cassette for North America (R4A, HP) Model : AM***NN4DCH/** History Version Modification Date Remark Ver.1. Released VRF Wind-Free 4Way Cassette for north America

More information

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH*** VRF Technical Data Book Slim duct for America (R41A, 6Hz, HP) Model : AM***FNLDCH*** History Version Modification Date Remark Ver.1. Release Slim duct for America (R41A, 6Hz, HP) 1.11.4 - Ver.1.1 1.12.28

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V PLXRMM1605 Wall Mounted FT-A Series COOLING ONLY [50Hz] 220-240V COMFORT 1 Daikin s FT-A series A simple, stylish and sleek wall mounted air conditioner that blends into any environment, providing the

More information

Wireless Remote Controller Kit

Wireless Remote Controller Kit INSTALLATION MANUAL Wireless Remote Controller Kit LS BRC4C8 Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)

More information

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA0AMVEB > FVA1AMVEB > FVA1AMVEB Indoor Unit FVA-A TABLE OF CONTENTS FVA-A 1 Features.............................................................

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

CTXA-AS/AT/AW, FTXA-AS/AT/AW

CTXA-AS/AT/AW, FTXA-AS/AT/AW Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-C Indoor Unit FTX-C TALE OF CONTENTS FTX-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2) DUCT TYPE AIR CONDITIONER (Cool) TYPE ADH4400G DH44ZA(A2) INDOOR UNIT IDH4400A DH44ZA(A2) OUTDOOR UNIT UDH4400G DH44ZAX SERVICE Manual AIR CONDITIONER CONTENTS. Product Specifications 2. Installation 3.

More information

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English. AIR CDITIER (SPLIT TYPE) Owner s Manual Wireless remote controller kit Model name: RBC-AX3U(W)-E RBC-AX3U(WS)-E Generic model name RBC-AX3U(W)-E Wireless remote controller model name WH-LSE Signal receiving

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

Super Digital Inverter / RAV Series 2010 Technical training

Super Digital Inverter / RAV Series 2010 Technical training Super Digital Inverter / RAV Series 2010 Technical training 1 PRESENTATION CONTENT Features Operation Safeties 2 FEATURES CONTENT System Line up & Model Numbers System Performance Operating envelope Electrical

More information

7. PCB AND FUNCTIONS

7. PCB AND FUNCTIONS Contents. PCB AND FUNCTIS. Outdoor Unit Control PCB... - -. Outdoor Unit Control PCB CR-C0DXH... - -. Outdoor Unit FAN PCB FAN-C00DXH... - -. Outdoor Unit FAN PCB FAN-C0DXH... - -. Outdoor Unit Filer PCB

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS 2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT

More information

Pocket Quick Reference Guide On the TOSHIBA

Pocket Quick Reference Guide On the TOSHIBA Pocket Quick Reference Guide On the TOSHIBA RBC-AMS51E / RBC-AMS54E Remote Controller Quick Reference Guide To assist service engineers working on Toshiba air conditioning equipment, there is a large quantity

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

INTERFACE SPECIFICATION

INTERFACE SPECIFICATION INTERFACE SPECIFICATION MODBUS CONVERTOR UTY-VMGX PART NO. 9708438030 Modbus is registered trademarks of Schneider Electric SA. LONWORKS is registered trademark of Echelon Corporation in the United States

More information

Single phase. Technical Support Division

Single phase. Technical Support Division Single phase Technical Support Division 2014.12 CMV MINI VRF System - Control System 1 1. Outdoor Unit and Indoor Unit PCB 2. Communication System 3. Controllers 2 CMV MINI VRF System - Control System

More information

VRF. Technical Data Book. DVM S Eco 8, 9 HP

VRF. Technical Data Book. DVM S Eco 8, 9 HP VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS Now Only One Unit Required for Initial Start-up Multi Zone Inverter Heat Pump High Efficiency Multi 21+ heat pump units can heat and cool up to 5 zones without

More information

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION 072 MULTI SPLIT 074 PRODUCT LINEUP 076 2 & 3-4 ROOMS MULTI 078 5-6 ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION TABLE 073 PRODUCT LINEUP MULTI SPLIT Outdoor Units FUJITSU

More information

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P)

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P) SINGLE Technical Data Book for North America (Low Ambient, R410A, 60Hz, H/P) Model : AC030/036KNZDCH/AA (IDU) AC030/036JXSCCH/AA (ODU) History Version Modification Date Remark Ver.1.0 Release SINGLE TDB

More information

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller Pocket Quick Reference Guide On the TOSHIBA RBC-AMS51E Remote Controller Quick Reference Guide To assist service engineers working on Toshiba air conditioning equipment, there is a large quantity of data

More information

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor 3 036 Room emperature Controller with 7-Day ime Switch, LCD and opt Remote emperature Sensor for heating systems RDE201 2-position control with ON/OFF output for heating Operating modes: normal operation

More information

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING Ductless Split Air Conditioner YR-E16b Wired Controller User Manual Set temp. 76 F Indoor temp. 70 F Indoor humidity 32%RH Qty. online Standby Defrost Master Outdoor temp. 36 F Outdoor humidity 32%RH Mode

More information

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound 24VNA9 Infinityr 19VS Variable Air Conditioner with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably small

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC009-EN Split System Cooling Product & Performance Data 2TTA2030-060A 2½ 5 Tons PUB. NO. 22-1735-01-0302 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA2 split systems

More information

OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER. MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000

OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER. MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000 OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000 Brivis Climate Systems Pty Ltd Tel:1300 BRIVIS brivis.com.au Thank you very much for purchasing our product.

More information

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL TOSH BA Carrier REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Owner's Manual Remote Controller Model name: Wireless remote controller kit TCB-AX21 UL Generic model name Wireless remote controller

More information

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P)

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P) SINGLE Technical Data Book for North America (Low Ambient, R410A, 60Hz, H/P) Model : AC030/036KNZDCH/AA (IDU) AC030/036JXSCCH/AA (ODU) History Version Modification Date Remark Ver.1.0 Release SINGLE TDB

More information

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB Air Conditioning Technical Data FHA-A > FHAAVEB > FHAAVEB > FHAAVEB > FHA71AVEB > FHA0AVEB > FHA1AVEB > FHA1AVEB TABLE OF CONTENTS FHA-A 1 Features.............................................................

More information

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC014-EN Split System Cooling Product & Performance Data 2TTA0030-072A 2½ 6 Tons PUB. NO. 22-1740-01-0702 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA0 split systems

More information

Communication Register Map - Uniflair Cooling

Communication Register Map - Uniflair Cooling DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide

More information

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER HVH8 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUP WITH OBSERVER COUNICATING CONTROL SYSTE 2 THRU 5 TONS SPLIT SYSTE 208 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Variable

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

NOTE CONTENTS NOTE-CONTENTS

NOTE CONTENTS NOTE-CONTENTS NOTE 1.The outline figure on cover is for reference only, which may differ from what you purchased. 2. Make sure to read chapter PRECAUTIONS before you operate the air conditioner. 3. This manual is available

More information

IntesisBox ModBus RTU Fujitsu Air Conditioning

IntesisBox ModBus RTU Fujitsu Air Conditioning IntesisBox ModBus RTU Fujitsu Air Conditioning Compatible with Domestic and VRF line air conditioners commercialized by Fujitsu User Manual 03/2019 r1.0 eng Intesis Software S.L.U. 2019 All Rights Reserved.

More information

TPE, TPED Series 2000

TPE, TPED Series 2000 GRUNDFOS INSTRUCTIONS TPE, TPED Series 2000 Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information

FPS SERIES Super Slim Ceiling Mount Air Handling Units

FPS SERIES Super Slim Ceiling Mount Air Handling Units About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning

More information

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and

More information

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments COOLING SOLUTIONS SmartRack Close-Coupled Cooling for IT Environments Efficient, flexible, manageable cooling reduces costs and simplifies installation. Efficient, flexible, manageable cooling for IT environments

More information

SPLIT lineup preview

SPLIT lineup preview Change things SPLIT - 2019 lineup preview DF19A021GB-00 The four Clivet families Feltre, 2019 SPLIT systems DF19A021GB-00-2 Light Commercial MULTI MONO STELVIO SCHIARA CRISTALLO ESSENTIAL 2 ODU-SM R-32

More information

Central Controller Operation & Installation Manual

Central Controller Operation & Installation Manual Central Controller Operation & Installation Manual YCZ-A004 CONTENT Function introduction of central controller... 1 Part info for central controller... 2 Page & Key Explanation... 4 Address Setting When

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210565 December 2010 Supersedes November 2010 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and provides up

More information

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

REMOTE CONTROLLER CS244-R OWNER S MANUAL

REMOTE CONTROLLER CS244-R OWNER S MANUAL OWNER S MANUAL REMOTE CONTROLLER Please read this Owner's Manual carefully before operation. Save this manual in a safe place for future reference. CS-R . After setting the TIMER, there will be a one-half

More information

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 288BNV EVOLUTION R V VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT 2, 3, 4 AND 5-TON Product Data The Evolutionr V heat pump offers high -efficiency variable speed performance in a remarkably small

More information

IntesisBox PA-AC-MBS-1

IntesisBox PA-AC-MBS-1 IntesisBox PA-AC-MBS-1 v.2.3 Modbus RTU (EIA-485) Interface for Panasonic air conditioners. Compatible with Etherea line air conditioners commercialized by Panasonic. User s Manual Issue Date: 11/2017

More information

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

Submittal Data Sheet intelligent Touch Manager DCM601A71

Submittal Data Sheet intelligent Touch Manager DCM601A71 For use with the following VRV Models: FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXTQ, FXUQ, FXZQ, VAM For use with the following Daikin SkyAir Models: FAQ, FBQ, FCQ, FHQ, FTQ Capacity:

More information

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners. IntesisBox FJ-RC-MBS-1 v.2.5 Modbus RTU (EIA-485) Interface for Fujitsu air conditioners. User Manual Issue Date: 12/2017 r1.9 EN Order Codes: FJ-RC-MBS-1: Modbus RTU Interface for Fujitsu air conditioners

More information

Rack cooling solutions for high density racks management, from 10 to 75 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw Rack cooling solutions for high density racks management, from 10 to 75 Superior efficiency, high reliability, low energy consumption Modern data center are characterized by 24/7 operation all year long.

More information

SINGLE. Technical Data Book Zone Control Systems

SINGLE. Technical Data Book Zone Control Systems SINGLE Technical Data Book Zone Control Systems Zone control system 2 I. Zone control system 1 Zone controller & remote temperature sensor 1. MWRZS00 / MWRZS10 / MRWTS 1) Features.... 4 2) Product specification...

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Adjustable swirl diffuser PDZA TECHNICAL DATA

Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high

More information

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw i-accurate_gb_07-2011 igh precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 Coming form 40 years experience in air conditioning and

More information

Wall mounted units. Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference.

Wall mounted units. Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference. OWNERS' MANUAL REMOTE CONTROLLER Wall mounted units Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference. Warning. Be sure there

More information

I. Individual control system

I. Individual control system Control Systems I. Individual control system 1 2 Wireless signal receiver kit MRK-A00 1) Features...................... 8 2) Wiring........................ 8 Wireless remote controller 4. MWR-VH02 1) Features.....................

More information

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx Chilled Water REMOTE CONTROLLER OPERATION MANUAL intensity.mx MAN-O-CRC4AH-061 CONTENTS Remote Controller Specifications---------------------------------------1 Performance Features-----------------------------------------------------1

More information

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial

More information

STRA-17 Room controller. Installation and maintenance manual. Content

STRA-17 Room controller. Installation and maintenance manual. Content Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8

More information

Product Data. 25HNA6 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HNA6 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons INDUSTRY LEADING FEATURES / BENEFITS Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons the environmentally sound refrigerant Carrier s heat pumps with Puron r refrigerant provide a collection of features

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210475 October 2009 Supersedes March 2009 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

SINGLE Technical Data Book. SINGLE for Europe (R410A, HP)

SINGLE Technical Data Book. SINGLE for Europe (R410A, HP) SINGLE Technical Data Book SINGLE for Europe (RA, HP) History Ver.. Release Single TDB for Europe.. Ver.. Add tcoe data (Specifications).. 9 Ver.... 9 CAC - World-class energy efficiency Maintain optimal

More information

Measure & Control Temperature & CO2 levels with analog & digital I/O

Measure & Control Temperature & CO2 levels with analog & digital I/O MADE IN OZ HTC-DIGITAL-LCD PROGRAMMABLE TEMPERATURE CONTROLLER c/w YEARLY PROGRAMMABLE TIME SWITCH COMPATIBLE WITH A WIDE RANGE OF SENSORS ROOM O/A WALL DUCT PIPE Use Features Measure & Control Temperature

More information

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS). PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable

More information

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name

More information

This document describes the features and functional specifications of the ECONO3 air conditioner controller.

This document describes the features and functional specifications of the ECONO3 air conditioner controller. TITLE : FUNCTIONAL SPECIFICATION FOR ECONO3 COOL REV : 01 DATE : MARCH 13, 2001. 1. INTRODUCTION 1.1 Scope of Document This document describes the features and functional specifications of the ECONO3 air

More information

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 Read and save these insturctions 2008 Antari Lighting & Effects Ltd. User Manual Antari DNG-200 Low fog Generator Congratulations on the purchase

More information

Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB

Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB Air Conditioning Technical Data FBA-A > FBAA2VEB > FBAA2VEB > FBAA2VEB > FBA71A2VEB > FBA0A2VEB > FBA1A2VEB > FBA1A2VEB Indoor Unit FBA-A TABLE OF CONTENTS FBA-A 1 Features.............................................................

More information