Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Size: px
Start display at page:

Download "Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration"

Transcription

1 Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional diagnostic features. Benefits Potted construction protects signal circuit from shock, vibration, humidity and/or condensation High chemical resistance Level detection independent of tank or pipe earth reference Insensitive to product buildup due to high frequency oscillation High sensitivity allows installation in a wide range of liquids, solids or slurry applications Integral LCD display allows for easy setup of CLS200 when you can configure switching threshold, even under the most demanding process conditions (digital version only) Extended rod, cable and sanitary versions available Standard version: 3 LED indicators for sensor status, output status and power SIL/IEC6108 compliant for use in safety integrated level applications for overfill protection (SIL-2) Digital version: integral LCD display, and PROFIBUS PA communication Application The is offered in standard and digital versions. The standard version has 3 LED indicators with basic relay and solid-state switch alarms. The digital version provides an integral LCD display for standalone use, and also provides PROFIBUS PA communication (Profile version 3.0 (P caps)) for connection to a network. The power supply is galvanically isolated and accepts a wide range of voltages (12 to 20 V AC/DC for standard version and 12 to 30 V DC for digital version). The stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to +12 C (+27 F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1. or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe.the CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic. Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas installation Siemens FI /1

2 Level instruments Technical specifications (Note: all specifications listed below apply to Standard and Digital versions unless otherwise noted) Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picofarad (pf) Output Output signal (CLS200 Standard) Relay output 1 SPDT Form C relay - Max. contact voltage 30 V DC 20 V AC - Max. contact current A (DC) 8 A (AC) - Max. switching capacity 10 W (DC) 2000 VA (AC) - Time delay (ON and/or OFF) 1 to 60 s Solid-state output - Output Galvanically isolated - Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < 1 V, typical at 0 ma - Time delay (pre or post switching) 1 to 60 s Output signal (CLS200 Digital) Solid-state output (CLS200 Digital) - Output Galvanically isolated - Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < 1 V, typical at 0 ma - Time delay (ON and/or OFF) Programmable by user (0 to 100 s) Fail-safe mode Min. or max. Connection Removable terminal block Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature -40 to +8 C (-40 to +18 F) Installation category II Pollution degree 4 Medium conditions Liquids, bulk solids, slurries and interfaces Relative dielectric constant ε r Min. 1. Temperature at process connection - Standard -40 to +8 C (-40 to +18 F) - Standard with thermal isolator -40 to +12 C (-40 to +27 F) Pressure (standard version and -1 to +2 bar g/ versions with extension) 2) to +36 psi g (nominal) Pressure (cable version) -1 to +10 bar g/ to +10 psi g (nominal) Pressure (optional sliding coupling version) Design Material -1 to +10 bar g/ to +10 psi g (nominal) - Enclosure Epoxy-coated aluminum with gasket - Optional thermal isolator 316L stainless steel Connection Removable terminal block, max. 2. mm² Degree of protection IP6/Type 4/NEMA 4 (optional IP68) Cable inlet 2 x M20x1. thread (option: 2 x ½" NPT conduit entry including 1 plugged entry), digital version has optional PROFIBUS PA connector Power supply (CLS200 Standard) 12 to 20 V AC/DC, 0 to 60 Hz max. 2 W Power supply (CLS200 Digital) Bus voltage Standard: 12 to 30 V DC Intrinsically Safe: 12 to 24 V DC Current consumption 12. ma Certificates and approvals (CLS200 Standard) General Purpose CE, CSA, FM Dust Ignition Proof (Intrinsically Safe probe circuit) Dust Ignition Proof (Cable version Intrinsically Safe probe) Explosion Proof (Intrinsically Safe probe circuit) Marine Overfill Protection Others CSA/FM Class II and III, Div. 1, Groups E, F, G T4 ATEX II 1/2 D T100 C CSA/FM Class I, Div. 1, Groups A, B, C, D T4 ATEX II 1/2 G EEx d[ia] IIC T6 to T4 Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV WHG (Germany) SIL/IEC6108 Declaration of Conformity [SIL-2 (overspill)] Pattern Approval (China) C-TICK (Australia) Certificates and approvals (CLS200 Digital) General Purpose CE, CSA, FM Intrinsically Safe CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4 or T6 3) ATEX II 1G 1/2D EEx ia IIC T6 to T4 T100 C 3) Explosion Proof/Dust Ignition Proof (Intrinsically Safe probe circuit) Non-incendive/Non-sparking Marine Others CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G T4 ATEX II 1/2G EEx d[ia] IIC T6 to T4 ATEX II 1/2D T100 C CSA/FM Class I, Div. 2, Groups A, B, C, D T4 or T6 CSA/FM Class II and III, Div. 2, Groups F, G ATEX II 3G 2D EEx na II T6 to T4 T100 C Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV Pattern Approval (China) C-TICK (Australia) /16 Siemens FI

3 Communication (CLS200 Digital) 1) 2) 3) PROFIBUS PA (IEC 6118 CPF3 CP3/2) Bus physical layer: IEC MBP (IS) Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /24. Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page /24. Barrier required for Intrinsically Safe protection Level instruments Standard version Sanitary version Cable version Max. length. m (18 ft). m (18 ft) 30 m (98 ft) liquids and slurries m (16 ft) solids (under loads) Process connection R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange 1) PFA coating (7ML0) has 120 micron thickness 2) FFKM available as special option. Contact nacc.smpi@siemens.com for details. 3) Thermal isolator is used if process connection temperature exceeds +30 C (+8 F). 1½", 2" sanitary fitting clamp 316L stainless steel R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange Extension material 316L stainless steel optional PFA coated 1) 316L stainless steel Fluoroethylene propylene (FEP) cable with stainless steel core Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) O-ring seal material 2) FKM FKM FKM Thermal isolator 3) Optional Optional Optional Extension User selected length User selected length Cable extension Siemens FI /17

4 Level instruments, threaded/sanitary version C) 7 M L Versatile inverse frequency shift capacitance level slurries, foam and interfaces Note: To select Standard or Digital CLS200 (with PROFIBUS PA), see final place holder under Electronics/output. Probe version (Threaded lengths include process thread) 1) 2) Compact,120 mm (4.72") 0 X 1) 2) Extended rod, 20 mm (9.84") 1 A Extended rod, 30 mm (13.78") 1) 3) 1 B Extended rod, 00 mm (19.69") 1) 3) 1 C 1) 3) Extended rod, 70 mm (29.3") 1 D 1) 3) Extended rod, 1000 mm (39.37") 1 E Add order code Y01 and plain text: Insertion length... mm" - Extended rod, 200 to 999 mm (7.87 to 39.33") 4) 1 F - Extended rod, 1001 to 2000 mm 1 G (39.41 to 78.74") 3) - Extended rod, 2001 to 3000 mm 1 H (78.78 to ") 3) ) - Extended rod, 3001 to 4000 mm 1 J (118.1 to 17.48") 3) ) - Extended rod, 4001 to 000 mm 1 K (17.2 to 196.8") 3) ) - Extended rod, 001 to 00 mm 1 L ( to 216.3") 3) ) Extended cable, 3000 mm (118.11"), length adjustable by customer 2 A 1) 2) Extended cable, 6000 mm (236.22"), length adjustable by customer1) 2) 2 B Add order code Y01 and plain text: Insertion length... mm" - Extended cable, 00 to 4999 mm 2 C (19.69 to ") 2) - Extended cable, 000 to 9999 mm 2 D (196.8 to ") 2) - Extended cable, to mm 2 E (393.7 to 90.") 2) - Extended cable, 1000 to mm 2 F (90.6 to 787.4") 2) - Extended cable, to mm 2 G (787.4 to 894.3") 2) - Extended cable, 2000 to mm 2 H (984.3 to ") 2) 1) 2) 6) Sanitary compact, 98 mm (3.8") 3 A Add order code Y01 and plain text: Insertion length... mm" - Sanitary extended, 110 to 1000 mm 3 B (4.3 to 39.3") 2) 7) - Sanitary extended, 1001 to 2000 mm 3 C (39.4 to 78.7") 2) 7) - Sanitary extended, 2001 to 3000 mm 3 D (78.8 to 118.1") 2) ) 7) - Sanitary extended, 3001 to 4000 mm 3 E (118.1 to 17.") 2) ) 7) - Sanitary extended, 4001 to 000 mm 3 F (17. to 196.9") 2) ) 7) - Sanitary extended, 001 to 00 mm 3 G (196.9 to 216.") 2) ) 7), threaded/sanitary version Versatile inverse frequency shift capacitance level C) 7 M L slurries, foam and interfaces Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A 1" NPT [(Taper), ANSI/ASME B1.20.1] B 1½" NPT [(Taper), ANSI/ASME B1.20.1] C R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] D R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 1¼" NPT [(Taper), ANSI/ASME B1.20.1] K G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), L JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] M G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), N JIS B 0202] 1" sanitary fitting clamp 8) 9) R 1½" sanitary fitting clamp 8) 9) S 2" sanitary fitting clamp 8) 9) T 2½" sanitary fitting clamp 8) 9) V 3" sanitary fitting clamp 8) 9) W Approvals General Purpose 1 CSA/FM Class II and III Div. 1, Groups E, F, G T4 10) 2 FM Class I Div. 1, Groups A, B, C, D T4 10) 3 CSA Class I, Div. 1, Groups A, B, C, D T4 10) 4 ATEX II 1/2 D T 100 C 10) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 10) 6 CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7 CSA/FM Class II and III, Div. 2, Groups F, G T4 or T6; ATEX II 3G 2D EEx na II T6 to T4 T100 C 6) CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8 E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 6) 11) T100 C CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0 E, F, G T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4 T100 C 6) Enclosure (see also option A01) Aluminum epoxy coated 2 x ½" NPT via adapter, cable inlet, IP6 0 2 x M20x1. cable inlet, IP6 1 2 x ½" NPT via adapter, cable inlet, IP x M20x1. cable inlet, IP68 3 Additional options Standard version (PPS probe body) A With thermal isolator (PPS probe body) B With PVDF probe body C With thermal isolator and PVDF probe body D With sliding coupling (PPS probe body) E With thermal isolator and sliding coupling F With sliding coupling and PVDF probe body G With thermal isolator, sliding coupling and PVDF H probe body WHG approval, German overfill protection Not required A Required 10) B Electronics/output Standard version without display, 12 to 20 V AC/DC, solid-state and relay output 12) 0 Digital version with display, 24 V DC, solid-state output or PROFIBUS PA 12) 13) 1 /18 Siemens FI

5 Level instruments, threaded/sanitary version C) 7 M L Versatile inverse frequency shift capacitance level slurries, foam and interfaces Further designs Please add -Z" to and specify Order code(s). Order code Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 38 mm (2.7 x 1.")]: Measuring-point number/identification (max. 20 charac- Y1 ters); specify in plain text Electrical connection/cable inlet: PROFIBUS PA A01 6) 14) 1) connector M12 Optional enclosure lid: Lid with glass window A04 instead of closed lid without window10) 12) Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN C12 SIL/IEC6108 Declaration of Conformity [SIL-2 C20 (overspill)] 10) Remote Electronics Remote mounted electronics with 2 m (79") cable A0 Remote mounted electronics with m (197") cable A06 Mounting bracket (including mounting kit) for remote electronics A09 Instruction manual See page /23 Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories See page /23 1) No Y01 needed in order code 2) Available with additional options A to D only 3) Available with additional options A to H 4) Lengths <30 mm (13.78") available with additional options A to D only ) Custom shipping methods required. Contact factory for more details. 6) Available with electronics option 1 only 7) Available with process connection R to W only 8) Available with version 3A to 3G only 9) Sanitary connection dimensionally corresponds to the applicable ISO 282 standard 10) Available with electronics option 0 only 11) Barrier required for Intrinsically Safe protection 12) Version with electronics option 0 has a closed lid without window as default; version with electronics option 1 has a lid with glass window as default. 13) An M12 PROFIBUS PA connector can be selected separately with wildcard option (A01). 14) Available with enclosure option 1 only 1) Available with approval option 1, 7, and 8 only C) Subject to export regulations AL: N, ECCN: EAR99 Siemens FI /19

6 Level instruments, welded flange C) 7 M L Versatile inverse frequency shift capacitance level slurries, foam and interfaces. Note: To select Standard or Digital CLS200 (with PROFIBUS PA), see final place holder under Electronics/output Probe version (length from flange face) Compact, 98 mm (3.86") 2) 0 X Extended rod, 20 mm (9.84") 2) 1 A Extended rod, 30 mm (13.78") 2) 1 B Extended rod, 00 mm (19.69") 2) 1 C Extended rod, 70 mm (29.3") 2) 1 D Extended rod, 1000 mm (39.37") 2) 1 E Add order code Y01 and plain text: Insertion length... mm" - Extended rod, 200 to 999 mm (7.87 to 39.33") 1 F - Extended rod, 1001 to 2000 mm 1 G (39.41 to 78.74") - Extended rod, 2001 to 3000 mm 1 H (78.78 to ") 1) - Extended rod, 3001 to 4000 mm 1 J (118.1 to 17.48") 1) - Extended rod, 4001 to 000 mm 1 K (17.2 to 196.8") 1) - Extended rod, 001 to 00 mm 1 L ( to 216.3") 1) Extended cable, 3000 mm (118.1"), length adjustable by customer 2) 2 A Extended cable, 6000 mm (236.2"), length adjustable by customer 2) 2 B Add order code Y01 and plain text: Insertion length... mm" - Extended cable, 00 to 4999 mm 2 C (19.69 to ") - Extended cable, 000 to 9999 mm 2 D (196.8 to ") - Extended cable, to mm 2 E (393.7 to 90.") - Extended cable, 1000 to mm 2 F (90.6 to 787.4") - Extended cable, to mm 2 G (787.4 to 894.3") - Extended cable, 2000 to mm 2 H (984.3 to ") Process connection Welded flange, 316L stainless steel, raised face 1" ASME, 10 lb A 1 1" ASME, 300 lb A 2 1" ASME, 600 lb A 3 1½" ASME, 10 lb B 1 1½" ASME, 300 lb B 2 1½" ASME, 600 lb B 3 2" ASME, 10 lb C 1 2" ASME, 300 lb C 2 2" ASME, 600 lb C 3 3" ASME, 10 lb D 1 3" ASME, 300 lb 1) D 2 3" ASME, 600 lb 1) D 3 4" ASME, 10 lb 1) E 1 4" ASME, 300 lb 1) E 2 4" ASME, 600 lb 1) E 3, welded flange C) 7 M L Versatile inverse frequency shift capacitance level slurries, foam and interfaces. Welded flange, 316L stainless steel, Type A flat faced DN 2, PN 16 J 4 DN 2, PN 40 J 6 DN 40, PN 16 K 4 DN 40, PN 40 K 6 DN 0, PN 16 L 4 DN 0, PN 40 L 6 DN 80, PN 16 M 4 DN 80, PN 40 1) M 6 DN 100, PN 16 1) N 4 DN 100, PN 40 1) N 6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN standard.) Approvals General Purpose 1 CSA/FM Class II and III Div. 1, Groups E, F, G T4 3) 2 FM Class I Div. 1, Groups A, B, C, D T4 3) 3 CSA Class I, Div. 1, Groups A, B, C, D T4 3) 4 ATEX II 1/2 D T100 C 3) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 3) 6 CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7 CSA/FM Class II and III, Div 2, Groups F, G T4 or T6; ATEX II 3G 2D EEx na II T6 to T4 T100 C 4) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8 E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 4) ) T100 C CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0 E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4 T100 C 4) Enclosure (see also option A01) Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP6 0 2 x M20x1. cable inlet, IP6 1 2 x ½" NPT via adapter - cable inlet, IP x M20x1. cable inlet, IP68 3 Additional options Standard version (PPS probe body) A With thermal isolator (PPS probe body) B With PVDF probe body C With thermal isolator and PVDF probe body D WHG approval, German overfill protection Not required A Required 3) B Electronics/output Standard version without display, 0 12 to 20 V AC/DC, solid-state and relay output 6) Digital version with display, 24 V DC, solid-state 1 output or PROFIBUS PA 6) 7) /20 Siemens FI

7 Level instruments, welded flange C) 7 M L Versatile inverse frequency shift capacitance level slurries, foam and interfaces. Further designs Order code Please add -Z" to and specify Order code(s). Total insertion length: enter the total Y01 insertion length in plain text description Stainless steel tag [69 x 38 mm (2.7 x 1.")]: Measuring-point number/identification (max. 20 charac- Y1 ters); specify in plain text Electrical connection/cable inlet: PROFIBUS PA A01 4) 8) 9) connector M12 Optional enclosure lid: Lid with glass window A04 instead of closed lid without window 6) Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN C12 SIL/IEC6108 Declaration of Conformity [SIL-2 C20 (overspill)] 3) Remote Electronics Remote mounted electronics with 2 m (79") cable A0 Remote mounted electronics with m (197") cable A06 Mounting bracket (including mounting kit) for remote electronics A09 Instruction manual See page /23 Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories See page /23 1) Custom shipping methods required. Contact factory for more details. 2) No Y01 needed in order code 3) Available with electronics option 0 only 4) Available with electronics option 1 only ) Barrier required for Intrinsically Safe protection 6) Version with electronics option 0 has a standard closed lid without window as default; version with electronics option 1 has a standard lid with glass window as default. 7) An M12 PROFIBUS PA connector can be selected separately with wildcard option (A01). 8) Available with enclosure option 1 only 9) Available with approval option 1, 7, and 8 only C) Subject to export regulations AL: N, ECCN: EAR99 Siemens FI /21

8 Level instruments, welded flange, PFA coated Versatile inverse frequency shift capacitance level C) 7 M L slurries, foam and interfaces. Note: To select Standard or Digital CLS200 (with PROFIBUS PA), see final place holder under Electronics/output Probe version (length from flange face) Compact, 98 mm (3.86") 1) 0 X Extended rod, 20 mm (9.84") 1) 1 A Extended rod, 30 mm (13.78") 1) 1 B Extended rod, 00 mm (19.69") 1) 1 C Extended rod, 70 mm (29.3") 1) 1 D Extended rod, 1000 mm (39.37") 1) 1 E Add order code Y01 and plain text: Insertion length... mm" - Extended rod, 200 to 999 mm (7.87 to 39.33") 1 F - Extended rod, 1001 to 2000 mm 1 G (39.41 to 78.74") - Extended rod, 2001 to 3000 mm (78.78 to ") 2) 1 H - Extended rod, 3001 to 4000 mm (118.1 to 17.48") 2) 1 J - Extended rod, 4001 to 000 mm (17.2 to 196.8") 2) 1 K - Extended rod, 001 to 00 mm ( to 216.3") 2) 1 L Process connection Welded flange, 316L stainless steel, raised face, PFA coated 1" ASME, 10 lb A 1 1" ASME, 300 lb A 2 1" ASME, 600 lb A 3 1½" ASME, 10 lb B 1 1½" ASME, 300 lb B 2 1½" ASME, 600 lb B 3 2" ASME, 10 lb C 1 2" ASME, 300 lb C 2 2" ASME, 600 lb C 3 3" ASME, 10 lb D 1 3" ASME, 300 lb 2) D 2 3" ASME, 600 lb 2) D 3 4" ASME, 10 lb 2) E1 4" ASME, 300 lb 2) E2 4" ASME, 600 lb 2) E3 Welded flange, 316L stainless steel, Type A flat faced, PFA coated DN 2, PN 16 J4 DN 2, PN 40 J6 DN 40, PN 16 K4 DN 40, PN 40 K6 DN 0, PN 16 L4 DN 0, PN 40 L6 DN 80, PN 16 M4 DN 80, PN 40 2) M6 DN 100, PN 16 2) N4 DN 100, PN 40 2) N6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16. or EN standard.), welded flange, PFA coated C) 7 M L 0 - Versatile inverse frequency shift capacitance level slurries, foam and interfaces. Approvals General Purpose 1 CSA/FM Class II and III Div. 1, Groups E, F, G T4 3) 2 FM Class I Div. 1, Groups A, B, C, D T4 3) 3 CSA Class I, Div. 1, Groups A, B, C, D T4 3) 4 ATEX II 1/2 D T100 C 3) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 3) 6 CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7 CSA/FM Class II and III, Div 2, Groups F, G; ATEX II 3G 2D EEx na II T6 to T4 T100 C 4) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8 E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 T100 C4) ) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0 E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4 T100 C 4) Enclosure (see also option A01) Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP6 0 2 x M20x1. cable inlet, IP6 1 2 x ½" NPT via adapter - cable inlet, IP x M20x1. cable inlet, IP68 3 Additional options Standard version (PPS Probe body) A With thermal isolator (PPS Probe body) B With PVDF probe body C With thermal isolator and PVDF probe body D WHG approval, German overfill protection Not required A Required 3) B Electronics/output Standard version without display, 12 to 0 20 V AC/DC, solid-state and relay output 6) Digital version with display, 24 V DC, solid-state 1 output or PROFIBUS PA 6) 7) Further designs Order code Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 38 mm (2.7 x 1.")]: Measuring-point number/identification (max. 20 charac- Y1 ters); specify in plain text Electrical connection/cable inlet: PROFIBUS PA A01 4) 8) 9) connector M12 Optional enclosure lid: Lid with glass window A04 instead of closed lid without window 6) Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN C12 SIL/IEC6108 Declaration of Conformity [SIL-2 C20 (overspill)] 3) Remote Electronics Remote mounted electronics with 2 m (79") cable A0 Remote mounted electronics with m (197") cable Mounting bracket (including mounting kit) for remote electronics A06 A09 /22 Siemens FI

9 Level instruments, welded flange, PFA coated C) 7 M L 0 - Versatile inverse frequency shift capacitance level slurries, foam and interfaces. Instruction manual See page /23 Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories See page /23 1) No Y01 needed in order code 2) Custom shipping methods required. Contact factory for more details. 3) Available with electronics option 0 only 4) Available with electronics option 1 only ) Barrier required for Intrinsically Safe protection 6) Version with electronics option 0 has a standard closed lid without window as default; version with electronics option 1 has a standard lid with glass window as default. 7) An M12 PROFIBUS PA connector can be selected separately with wildcard option (A01). 8) Available only with enclosure option 1 9) Available with approval option 1, 7, and 8 only C) Subject to export regulations AL: N, ECCN: EAR99 Instruction manual English 7ML1998-AR02 French 7ML1998-AR12 German 7ML1998-AR32 Note: The instruction manual should be ordered as a separate line on the order. Additional instruction manual Quick Start manual, multi-language 7ML1998-QE81 Note: Due to ATEX regulations, one Quick Start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories Sensguard, ¾" NPT (PPS) 7ML1830-1DL Only available for CLS200 with ¾" NPT thread Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM Only available for CLS200 with ¾" NPT thread ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 C (-40 to +212 F), IP68 (General Purpose) ½" NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB and EEx e II, fits cable diameter 6. to 14 mm (0.26 to 0."), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) M20x1. cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC EEx e II, fits cable diameter 7 to 12 mm (0.28 to 0.47"), -20 to +70 C (-4 to +18 F), IP68 (General Purpose) M20x1. cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD and EEx e II, fits cable diameter 10. to 1.9 mm (0.41 to 0.63"), under armour cable diameter 6.1 to 11. mm (0.24 to 0.4"), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) One metallic cable gland M20x1., -40 to +80 C 7ML1930-1AP (-40 to +176 F) One metallic cable gland M20x1., -40 to +80 C 7ML1930-1AQ (-40 to +176 F) with integrated shield connection (available for PROFIBUS PA) Blind threaded flanges are available. Please contact nacc.smpi@siemens.com with a completed application data sheet on page /8 Spare parts Test magnet (digital version) 7ML1830-1JE Amplifier/power supply, standard version C) 7ML1830-1DJ Amplifier/power supply, digital version 7ML1830-1JF LCD display (digital version) 7ML1830-1JK C) Subject to export regulations AL: N, ECCN: EAR99 F) Subject to export regulations AL: 9I999, ECCN: N Options Optional Sensguard dimensions Siemens FI /23

10 Level instruments Characteristic curves P Example: Permitted operating pressure = 10 bar (14 psi) at 7 C T Pressure/Temperature Curve CLS200 Sliding Coupling Threaded Process Connections (7ML02) P = Permitted Operating Pressures T = Permitted Operating Temperature Process Pressure/Temperature derating curves (7ML02) Process Pressure/Temperature derating curves (7ML02) /24 Siemens FI

11 Level instruments Process Pressure/Temperature derating curves (7ML02) Process Pressure/Temperature derating curves (7ML02) Siemens FI /2

12 Level instruments Process Pressure/Temperature derating curves (7ML04) Process Pressure/Temperature derating curves (7ML04 and 7ML0) /26 Siemens FI

13 Level instruments Process Pressure/Temperature derating curves (7ML04) Process Pressure/Temperature derating curves (7ML04 and 7ML0) Siemens FI /27

14 Level instruments Dimensional drawings dimensions - Threaded/Sanitary Process Connections /28 Siemens FI

15 Level instruments dimensions - Flanged Process Connections Siemens FI /29

16 Level instruments Schematics connections /30 Siemens FI

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31 Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific

More information

Selection and Ordering data. Selection and Ordering data

Selection and Ordering data. Selection and Ordering data Pointek CLS3, threaded version 7 M L 5 5-7 7777-77 7 Note: To select Standard or Digital CLS3 (with PROFIUS P), see final place holder under. Probe version (Threaded lengths include process thread.) Standard

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Configuration. Installation

Configuration. Installation Overview SITRANS LR20 measures superbly in small vessels and in tanks/vessels up to 10 m (32 ft) on materials with dk > 3. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous

More information

Siemens AG Level Measurement

Siemens AG Level Measurement Level Measurement /2 Product Overview Point level measurement /7 Capacitance switches /10 Pointek CLS100 /16 Pointek CLS200 Standard /25 Pointek CLS200 Digital /3 Pointek CLS200 - Standard and Digital

More information

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation Siemens AG 201 Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open

More information

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transducers Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level Measurement Overview Echomax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level measurement Overview EchoMax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

Level limit switch Series RF 3000 Selection list. Overview 2

Level limit switch Series RF 3000 Selection list. Overview 2 Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview. Overview onfiguration 2-wire, 78 GHz FMW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). enefits rugged stainless steel design for industrial applications

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 1 m (1 to 0 ft), transducer dependent Measuring points 1 or 2 Input Analog 0

More information

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage. Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10

More information

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Assembly. Function 41

Assembly. Function 41 Capacitive limit switch Features Assembly Limit switch for liquids and bulk solids Device with rod probe Complete unit consisting of the probe and electronic insert Integrated active build-up compensation:

More information

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview. SITRANS LU and LU Siemens AG Overview Overview The SITRANS LU is an ultrasonic long-range level controller for liquids and solids in a single vessel up to 6 m ( ft). Handheld programmer shown is an accessory

More information

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Overview The SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, solids,

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Overview The SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, solids,

More information

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview Flow Measurement Siemens AG 2012 Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement from plant vibration

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids Technical Information Level limit switch for multiple point detection in conductive liquids Applications The Liquipoint T sensors are used in conductive liquids (down to 0 µs/cm) for determining level

More information

Siemens AG Continuous level measurement Ultrasonic controllers

Siemens AG Continuous level measurement Ultrasonic controllers Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of

More information

LS 5000 series Vibration Level Switch for liquids

LS 5000 series Vibration Level Switch for liquids Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,

More information

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195 Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

CAPACITIVE: CONTROL CLS2 CLS4 CLS5. Applications liquids / solids liquids / solids solids / granules

CAPACITIVE: CONTROL CLS2 CLS4 CLS5. Applications liquids / solids liquids / solids solids / granules CAPACITIVE: CONTROL On/Off Capacitive control is an established and extensively used level control technique. The instrument is composed of an electrode, suitable for the application, and of an electronic

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI SITRANS LUC00 Siemens AG 009 Overview SITRANS LUC00 is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms.

More information

Liquipoint T FTW31, FTW32

Liquipoint T FTW31, FTW32 TI00375F/00/EN/14.16 71336942 Products Solutions Services Technical Information Liquipoint T FTW31, FTW32 Conductive Point level switch for multiple point detection in conductive liquids Applications The

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57 XA00531F-D/00/EN/16.16 71313127 Products Solutions Services Safety Instructions FMP50/51/52/53/54/55/56/57 4-20 ma HART Control Drawing IS Document: XA00531F-D Safety instructions for electrical apparatus

More information

SITRANS F flowmeters SITRANS F US

SITRANS F flowmeters SITRANS F US SITRANS F flowmeters Siemens AG 2008 Overview Application SITRANS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering Allocation Flow survey verification Lost

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Spare Parts for RM71 SmartLine Guided Radar Level Meter

Spare Parts for RM71 SmartLine Guided Radar Level Meter Spare Parts f RM71 SmartLine Guided Radar Level Meter XM71 All but 2mm F 2mm probe style see MSG 36-RM-16-06 (XM72) 36-RM-16U-05 Page 1 of 8 Model Selection Guide Supply the iginal instrument model code

More information

Level measurement. Applications. Special features. Description

Level measurement. Applications. Special features. Description Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data

More information

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and

More information

Continuous level measurement Ultrasonic controllers

Continuous level measurement Ultrasonic controllers Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and

More information

Quick Start Manual April English Dansk Deutsch. Español Français Italiano Nederlands Português Suomi Svenska. sitrans LG200

Quick Start Manual April English Dansk Deutsch. Español Français Italiano Nederlands Português Suomi Svenska. sitrans LG200 Quick Start Manual April 2009 Dansk Deutsch Español Français Italiano Nederlands Português Suomi Svenska sitrans LG200 SITRANS LG200 Quick Start Manual This manual outlines the essential features and

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range of industries. Application can be used with various

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Temperature Measurement SITRANS TS300

Temperature Measurement SITRANS TS300 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2 PROCESS AUTOMATION TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2 Vibration Limit Switch Limit Switch for Bulk Solids ISO9001 With regard to the supply of products, the current issue of the following document

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

LS 6600 Technical Datasheet

LS 6600 Technical Datasheet Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301

More information

OPTISWITCH 6600 C Technical Datasheet

OPTISWITCH 6600 C Technical Datasheet Technical Datasheet Microwave Level Switch for standard hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE CONTENTS

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP Capacitive Overview 116 VEGACAP series 60 120 VEGACAP 27, 35, 98 132 Capacitive VEGACAP 115 VEGACAP Level detection in bulk solids and liquids Measuring principle Sensor and vessel form the two electrodes

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12 www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently

More information

Magnetic float switch For vertical installation Model FLS

Magnetic float switch For vertical installation Model FLS Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Signet 2552 Metal Magmeter Flow Sensors

Signet 2552 Metal Magmeter Flow Sensors Signet 2552 Metal Magmeter Flow s Features Test certificate included Award winning hot-tap magnetic flow sensor up to DN2550 (102 in.) Patented Magmeter technology* Operating range 0.05 to 10 m/s (0.15

More information

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071 www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or

More information