Self Contained - Non Lever Bypass

Size: px
Start display at page:

Download "Self Contained - Non Lever Bypass"

Transcription

1 Self Contained - Non 125 & 200 Amp Continuous VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel 5th jaw provision at nine (9) o clock EN20L43GRST shown open & closed Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets hub assemblies Cap setscrew assemblies Horn bypass cap assemblies 5th jaw terminal kits Lug kits Jumper links Closing plates Touch-up paint Part/UPC Catalog Top Service No. of Conductors Ground Prov. Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 125 Amp - Continuous (AIC Rated per Table RL1 on page 42) EN12L41GRST OH Opening 1Ø/3W 4 None #10 G-#2 G EN12L41GRST MS76 OH 125 1Ø/3W 4 None #10 G-#2 G EN12L42GRST UG None 1Ø/3W 4 None #10 G-#2 G EN12L43GRST CAP 1Ø/3W 4 None #10 G-#2 G 200 Amp - Continuous (AIC Rated per Table RL1 on page 42) EN20L41GRST OH Opening 1Ø/3W 4 None #10 G-#2 G EN20L42GRST UG None 1Ø/3W 4 None #10 G-#2 G EN20L43GRST CAP 1Ø/3W 4 None #10 G-#2 G EN20L4RST UG - Bussed Offset None 1Ø/3W 4 None #10 G-#2 G 12 1 /8 8 1 /4 5 1 /4 Fig /4 8 1 /4 5 1 /4 Fig / /4 5 1 /4 Fig / /4 5 1 /4 Fig /8 8 1 /4 5 1 /4 Fig / /4 5 1 /4 Fig / /4 5 1 /4 Fig / /4 5 1 /4 Fig. 7 4

2 Self Contained - Non Knockout Layouts 125 & 200 Amp Continuous VAC Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Knockouts - Conduit Sizes = 1 2" - 3 8" dia. 2D = 1 1 2" " = " " - 1 = 2 1 2" " " = " " = Hub Opening (Small) 2D Fig. 7 5

3 Self Contained - Non-Jaw Clamping 125 Amp Continuous VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel EC12L41GR1N Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets hub assemblies Cap setscrew assemblies 5th jaw terminal kits Lug kits Closing plates Touch-up paint EC12L71GRST Part/UPC Catalog Top Service No. of Conductors Ground Provision Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 125 Amp - Continuous (AIC Rated per Table RL1 on page 42) EC12L41GR1N OH 1Ø/3W 5 NJCLB * Opening #10 G-#2 G EC12L43GR2N CAP 1Ø/3W 5 NJCLB * EC12L71GRST OH Opening 3Ø/4W 7 NJCLB * #10 G-#2 G * lever operates bypass only, non-jaw clamping Includes 5th jaw kit installed at nine (9) o clock, may be relocated at six (6) o clock 19 1 / /4 5 5 /8 Fig / /4 5 1 /2 Fig / /4 5 5 /8 Fig. 3 6

4 Self Contained - Non-Jaw Clamping 125 Amp Continuous VAC Knockout Layouts 1V 1V Fig. 1 Fig. 2 Fig. 3 Knockouts - Conduit Sizes 1V = 1 2" dia. = 1 4" dia. 1Z = 7 16" dia. = 3 4" - 1 2" = " " = 2 1 2" " " - 1 = Hub Opening (Small) 7

5 Self Contained Amp Continuous VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel EL20L53GRST EL20L73GRST Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets & H-Base hub assemblies Cap setscrew assemblies 5th jaw terminal kits Lug kits Closing plates Touch-up paint Part/UPC Catalog Top Service No. of Conductors Ground Provision Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 200 Amp - Continuous (AIC Rated per Table RL1 on page 42) EL20L41GR1N OH 1Ø/3W 5 Opening EL20L41GR2N OH H7 1Ø/3W 5 #14-2/0 G EL20L43GRST CAP 1Ø/3W EL20L43GR2N H7/ CAP 1Ø/3W 4 ##14-2/0 G EL20L4RST UG Bussed offset None 1Ø/3W 4 #10-2/0 G EL20L4R1N Non-bussed offset H10 1Ø/3W EL20L51GRST OH Opening 1Ø/3W or 3Ø/3W EL20L51GR2N OH 1Ø/3W 5 Opening or 3Ø/3W EL20L53GRST CAP 1Ø/3W or 3Ø/3W EL20L71GRST OH Opening 3Ø/4W EL20L71GR1N OH Opening 3Ø/4W EL20L71GR2N OH H7 3Ø/4W EL20L73GRST CAP 3Ø/4W EL20L73GR2N CAP H7 3Ø/4W EL20L7R1N Non-bussed offset H10 3Ø/4W / /4 5 5 /8 Fig / /4 5 5 /8 Fig / /4 5 5 /8 Fig / /4 5 1 /2 Fig / /4 5 5 /8 Fig / /4 6 5 /8 Fig / /4 5 5 /8 Fig / /4 5 1 /2 Fig / /4 5 5 /8 Fig / /4 5 5 /8 Fig / /4 5 5 /8 Fig / /4 5 1 /2 Fig / /4 5 5 /8 Fig / /4 5 1 /2 Fig / /4 6 5 /8 Fig. 6 5th jaw provisions at six (6) o clock and nine (9) o clock Includes 5th jaw kit installed at nine (9) o clock, may be relocated at six (6) o clock Includes 5th jaw kit installed at six (6) o clock, may be relocated at nine (9) o clock

6 Self Contained Amp Continuous VAC Knockout Layouts HH 1V Fig. 1 1V Fig. 2 Fig. 3 Fig. 4 HH 1Z 4J 4J 4J Fig. 5 1Y Fig. 6 Fig. 7 1V Fig. 8 Knockouts - Conduit Sizes 1V Fig. 9 Fig. 10 1V = 1 2" dia. = 1 4" dia. 1Y = 5 16" dia. 1Z = 7 16" dia. = 3 4" - 1 2" = " " 4J = 3 1 2" " - 2 = 2 1 2" " " - 1 = Hub Opening (Small) HH = H Hub Opening (Large) 9

7 Self Contained Amp Continuous VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel EL32T76GRST shown open & closed Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets H-Base hub assemblies 5th jaw terminal kits Lug kits Lug/stud landing pads Closing plates Touch-up paint Part/UPC Catalog Top Service No. of Conductors Ground Provision Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 320 Amp - Continuous (AIC Rated per Table RL9 on page 43) EL32T4RST EL32T4R1N EL32T46GRST EL32T7R1N EL32T76GRST 5th jaw provisions at six (6) o clock and nine (9) o clock UG None 1Ø/3W 4 3 /8-16 Stud Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 1Ø/3W 4 3 /8-16 Stud Non-Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 1Ø/3W 4 3 /8-16 Stud Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 3Ø/4W 7 3 /8-16 Stud Non-Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 3Ø/4W 7 3 /8-16 Stud Bussed Offset 3 /8-16 Stud #10 G-1/0 G 27 5 / /4 7 1 /8 Fig / /4 7 1 /8 Fig / /4 7 1 /8 Fig / /4 7 1 /8 Fig / /4 7 1 /8 Fig. 3 10

8 Self Contained - Knockout Layouts 320 Amp Continuous VAC HH 1Y Fig. 1 1Y Fig. 2 HH Knockouts - Conduit Sizes 1Y = 5 16" dia. 1Z = 7 16" dia. = 3 4" - 1 2" = 4, 3 1 2" " HH = H Hub Opening (Large) 1Y Fig. 3 11

Self Contained - Non-Jaw Clamping Lever Bypass

Self Contained - Non-Jaw Clamping Lever Bypass Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction

More information

Illinois and Northwest Indiana Metering Equipment

Illinois and Northwest Indiana Metering Equipment Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Servicing : Ameren UE, Commonwealth Edison, Ameren IP (Illinois Power Utility), Northern Indiana and Public Service (NIPSCO) Illinois

More information

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs

More information

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.

More information

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

alid portable power cart epcc  panel ccts EPCC-60 40 60A, 120/208V 3PH 24 EPCC  100A, 120/208V 3PH 24 portable power cart epcc Features/Specifications 12GA Steel construction CSA Type 3R rated Pin & Sleeve inlet connector Pad-lockable door Up to12 receptacles Cut-out in bottom to provide while-in-use Polyurethane,

More information

Cooper B-Line RESIDENTIAL SERVICES

Cooper B-Line RESIDENTIAL SERVICES RESIDENTIAL SERVICES Approved Voltage Optional Voltage w/utility Approval 011 011 5 th Clip 100 Amp Socket Only, Overhead 011F 011F 5 th Clip 100 Amp Meter Socket & Circuit 1M1R 1M1R 5 th Clip Breaker

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM. Spec-224 H763.422.2211 763.422.26 SEQUESTR Preferred-Cutout s SEQUESTR External s SEQUESTR Preferred-Cutout s SEQUESTR External s SEQUESTR External Package, Type 12 FEATURES INUSTRY STANARS UL 58A Listed;

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral conductors. Variety of connectors

More information

Power-Style QED-2, Series 2 Low Voltage Switchboards

Power-Style QED-2, Series 2 Low Voltage Switchboards Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................

More information

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS Spec-224 Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E61997 NEMA/EEMAC Type 12 CSA

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12 Spec-224 SEQUESTR Preferred-Cutout isconnects SEQUESTR External isconnects Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per

More information

HomeWorks Remote Power Feed-Through Panels

HomeWorks Remote Power Feed-Through Panels power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power

More information

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential. CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N

More information

Power Mod. Introduction and Contents. Revised 02/18/14

Power Mod. Introduction and Contents. Revised 02/18/14 Introduction and Contents 02/18/14 2 METER Siemens Power Mod is a robust, flexible, and feature-rich line of modular metering designed to exceed today s market demands. Power Mod s exclusive QuickSystem

More information

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution. Technical Datasheet Tier Power Systems, Inc. iq Series UL 1558 Switchgear Tier Power Systems iq Series is a leader in switchgear technology. iq Series provides advanced power distribution technology and

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Free-Standing Type 12 Enclosures

Free-Standing Type 12 Enclosures Type 12 Enclosures Application Designed to protect electrical and electronic controls, components, and instruments in typical industrial environments. The UL Type 12 rating protects enclosed equipment

More information

ASCO SERIES 300 Service Entrance Power Transfer Switch

ASCO SERIES 300 Service Entrance Power Transfer Switch ASCO SERIES 300 Service Entrance Power Transfer Switch The ASCO Service Entrance Power Transfer Switch combines automatic power switching with the necessary disconnecting, grounding, and bonding required

More information

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire

More information

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects 763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42

More information

Datasheet. Fiber Optic Modular Patch Panel Features

Datasheet. Fiber Optic Modular Patch Panel Features Features Very high density, supports up to 24 duplex LC adapters (48 fibers), MT-RJ adapters (48 fibers) and simplex SC adapters (24 fibers) in 1U of rack space Pullout drawer enables ease of access to

More information

Cord- Mounted Female. Mounted Male. Strain relief clamp # needs to be ordered separately w/cord-mounted connections.

Cord- Mounted Female. Mounted Male. Strain relief clamp # needs to be ordered separately w/cord-mounted connections. -Pin Amp Plastic 0883 Kit (consists of) 080 Receptacle 03 Pins (Qty ) 088 Kit (consists of) 080 Connector 03 Sockets (Qty ) Note: Strain relief clamp 03 needs to be ordered separately with cord-mounted

More information

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Fiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X

Fiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X 763.22.2600 Spec-00092 L763.22.2211 Fiberglass Hinge-Cover with 3-Point Latch or Quick-Release Latches Fiberglass Hinge-Cover with 3-Point Latch or Quick-Release Latches Hinge-Cover with 3-Point Latch

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

PANELITE ENCLOSURE LIGHTS OVERVIEW

PANELITE ENCLOSURE LIGHTS OVERVIEW SPEC-00581 H763.422.2211 763.422.2600 ELECTRICAL LIGHTING PACKAGES ELECTRICAL LIGHTING PACKAGES PANELITE ENCLOSURE LIGHTS OVERVIEW FEATURES Slim profile allows light to be tucked up out of the way for

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,

More information

NT-2300 Series Dual Circuit Track System & Accessories

NT-2300 Series Dual Circuit Track System & Accessories ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Type 4 Disconnect Enclosures

Type 4 Disconnect Enclosures 143 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed to work in a wide range of environments indoors or outdoors, and will house most standard types of disconnects

More information

Rack- and Panel-Mount Power Distribution Units (PDUs)

Rack- and Panel-Mount Power Distribution Units (PDUs) Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES Power on/off LED indicates whether power is available at the PDU External

More information

CONCEPT Stainless Steel Wall-Mount Enclosures

CONCEPT Stainless Steel Wall-Mount Enclosures CONCEPT Stainless Steel Wall-Mount Finish are unpainted. Door and body have smooth #4 brushed finish. Optional CONCEPT panels are white painted or zinc-plated. Optional NEMA panels are white painted, zinc-plated,

More information

Brush installation units made of plastic, quadrangular Assembly instruction

Brush installation units made of plastic, quadrangular Assembly instruction Brush installation units made of plastic, quadrangular Brush installation units made of plastic, quadrangular Quadrangular installation unit with a brush cable outlet and external dimensions of 280 x 280

More information

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading 1/6 CR Series Ceiling Rack Systems with AmbiTILT Equipment Loading General Description AtlasIED, the manufacturing leader of ceiling mounted loudspeakers introduces the new CR Series ceiling-mounted equipment

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Rack- and Panel-Mount Power Distribution Units (PDUs)

Rack- and Panel-Mount Power Distribution Units (PDUs) Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES INDUSTRY STANDARDS UL/cUL 60950 listed UL 1449 (Surge protector models

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product

More information

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without

More information

NETXTEND JUICEBOX SERIES Power Transfer Switches

NETXTEND JUICEBOX SERIES Power Transfer Switches NETXTEND JUICEBOX SERIES Power Transfer Switches NETXTEND JUICEBOX SERIES KEY FEATURES yul 891 Dead Front Switchboard or UL67 Panel Board Listed to industry standards for electrical requirements yul 3R

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

Explosionproof Meter Housings

Explosionproof Meter Housings METER HOUSINGS Explosionproof Drilled and tapped to specification, attach layout sheet. Dimensions are internal. XJDGCH N4 XJDFGCH N4 4 1/8 x 4 1/8 X 3 XJMCGCH N4 6 3/4 x 6 3/4 x 3 XJTGCH N4 XJTFGCH N4

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects 763.422.2600 SPEC-01054 C763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 4 DISCONNECTS FREE-STAND DISCONNECT WITH QUICK-RELEASE CONTINUOUS HINGE, TYPE 4 APPLICATION Simple,

More information

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU Flat Screen Garage Table System Planning Guide ORKING FOR YOU Introduction Bring a new level of performance to any room with KI s Flat Screen Garage. This versatile system does double duty to make the

More information

INTERAPID Depth Feet. Brown & Sharpe CENTER FINDER. Model with a flat measuring face. Model with a prismatic measuring face H-16

INTERAPID Depth Feet. Brown & Sharpe CENTER FINDER. Model with a flat measuring face. Model with a prismatic measuring face H-16 INTERAPID Depth Feet Model with a flat measuring face ø28 ø8 Finish lapped measuring faces. Clamp with lock for mounting a dial gauge or an electronic probe Supplied ø6.5 without indicator 80 Suited carrying

More information

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0 Contents DMC2

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

TRD0359 REV A - Parts Manual 2015 DCN-1363, JAN 09, 2015 SWING-AWAY LATERALS

TRD0359 REV A - Parts Manual 2015 DCN-1363, JAN 09, 2015 SWING-AWAY LATERALS SWING-AWAY LATERALS Product/Device Description: Cane Mounted Laterals Device Master Record Document No. DMR-5 Document Rev. A Page of 5 Device No.: D-05. Purpose This record contains references to all

More information

Meter Breakers. Technical Data. Contents

Meter Breakers. Technical Data. Contents Technical Data Effective: October Page ew Information Meter reakers Contents Description Page Residential Meter reakers Residential Meter reakers...................................... Product Selection..............................................,

More information

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products CHAPTER : Disconnect Featured Products in this Chapter CONCEPT Disconnect Enclosure, Type 4X P. 319 Fiberglass Disconnect, Type 4X P. 328 WATERSHED Disconnect Enclosure, Type 4X P. 340 SEQUESTR External

More information

PACSystems RX7i IC698CHS009/119

PACSystems RX7i IC698CHS009/119 January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i

More information

Innovative POWER Solutions

Innovative POWER Solutions Innovative POWER Solutions ISO 9001 : 2008 REGISTERED QUALITY MANAGEMENT SYSTEM PANTROL, INC. INVITES YOU TO REVIEW A SAMPLING OF OUR STANDARD PRODUCTS LINE. FOR SPECIAL APPLICATIONS OR CONFIGURATIONS

More information

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST 151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed to work in a wide range of environments indoors or outdoors, and house electronic controls, instruments,

More information

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator

More information

Universal MATE-N-LOK Headers for UMNL II Connectors

Universal MATE-N-LOK Headers for UMNL II Connectors for UMNL II Connectors PC Board Vertical Pin Headers [6.5] Centerline spacing,, and 5 Circuit, In-Line Housing Nylon Flammability ating UL9V-0 Contacts Phosphor bronze Solder tail diameter.06 [1.57] elated

More information

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT ISOLATION Info: 9070 = Isolation RELAY RACK ISOLATION KIT 19 RACK MOUNT 9070-1019 19" Rack Mount 23 RACK MOUNT 9070-1023 23" Rack Mount RELAY RACK ISOLATION (KIT) RELAY RACK ISOLATION KIT, SLOTTED 19 RACK

More information

RL Line/Load Reactors

RL Line/Load Reactors RL Line/Load Reactors Selection Table, Technical Details & Product Application Guide MTE HARMONIC COMPENSATED LINE/LOAD REACTORS help keep your equipment running longer by absorbing many of the power line

More information

fine-stranded solid V A mm mm V/8 kv/3 32 No AWG 600 V 30/35 No AWG 600 V 40 6 mm 9 mm aüigotucf+qkw h

fine-stranded solid V A mm mm V/8 kv/3 32 No AWG 600 V 30/35 No AWG 600 V 40 6 mm 9 mm aüigotucf+qkw h Terminal blocks with screw connection for junction boxes, type WKI selos BIT EN 60 947-7-1/DIN VDE 0611 T1 UL ratings CSA ratings Width Approvals Feed-through block Feed-through block field-/factory wiring

More information

SecTER cabinet COOPER POWER SERIES. Sectionalizing Cabinets Catalog Data CA901001EN. General. Optional features

SecTER cabinet COOPER POWER SERIES. Sectionalizing Cabinets Catalog Data CA901001EN. General. Optional features Sectionalizing Cabinets Catalog Data CA901001EN SecTER cabinet Supersedes 1000-05 February 2012 COOPER POWER SERIES General Eaton's Cooper Power series versatile singleand three-phase SecTER sectionalizing

More information

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

Power-Over-Ethernet Weatherproof 18 x 16 x 8 Enclosure with Equipment Mounting Plate and Cooling Fans Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet

More information

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching 7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that

More information

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS 120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB181608-10FS Applications and Features Features: Molded Fiberglass Reinforced Polyester

More information

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for

More information

600-Amp Elbow Connectors 600 Series Deadbreak Components

600-Amp Elbow Connectors 600 Series Deadbreak Components 600-Amp Elbow Connectors 600 Series Deadbreak Components 600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary

More information

NetXtend JuiceBox Series Integrate Enclosure Solution. Outside Plant for Business-Critical Continuity

NetXtend JuiceBox Series Integrate Enclosure Solution. Outside Plant for Business-Critical Continuity NetXtend JuiceBox Series Integrate Enclosure Solution Outside Plant for Business-Critical Continuity Key Features n UL 891 Dead Front Switchboard or UL67 Panel Board Listed to industry standards for electrical

More information

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying Page 1 of 6 B Y R N E 8 - T R A C O V E R V I E W 1) Introduction Byrne Electrical Specialists, Inc. provides quality, cost effective, innovative power/data distribution solutions. From initial concept

More information

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,

More information

Two Circuit Track Power System IS24 / IS26 / IS28

Two Circuit Track Power System IS24 / IS26 / IS28 Two Circuit Track Power System IS24 / IS26 / IS28 DESCRIPTION Two circuit / single neutral track is an affordable and durable solution that features easy installation. Track system is available in 4, 6,

More information

ACTUATOR. Terminal Blocks. Terminal Blocks. motor. motor. input 24 VDC. input 24 VDC. input 24 VDC RQ60DUM RQ60DUM. Control Circuit.

ACTUATOR. Terminal Blocks. Terminal Blocks. motor. motor. input 24 VDC. input 24 VDC. input 24 VDC RQ60DUM RQ60DUM. Control Circuit. bar N L Switch B Switch A Dry Contact - Installation Guide This installation guide is for dry contact switches and their connectivity with home automation, building management systems and stand alone automation

More information

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale Outdoor Transmission ( kv through 230 kv) For Line and Cable Switching Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified

More information

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4 763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless

More information

9.3. Metering Devices, Protective Relays, Software and Connectivity

9.3. Metering Devices, Protective Relays, Software and Connectivity .3, Protective Relays, Software and Connectivity Product Eaton s IQ Multipoint Energy Submeter II is a revenue class electronic submetering device that can be mounted in panelboards or switchboards. When

More information

Single-Phase Encapsulated

Single-Phase Encapsulated Single-Phase Encapsulated 7 50 VA to 25 kva Applications n For general loads, indoors or out, including lighting, industrial and commercial applications n Units may be banked for 3-Phase operations n For

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

U-SERIES SPECIFICATION GUIDE

U-SERIES SPECIFICATION GUIDE U-SERIES SPECIFICATION GUIDE Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND

More information

Sit-to-Stand Workstation

Sit-to-Stand Workstation Sit-to-Stand Workstation Product ID: ARMSTS This sit-to-stand workstation lets you change your working position throughout the day, to enhance your comfort and productivity. Go from sit to stand, with

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

Technical Operating Information AC Unit (T150116G100) Replacement Filter No pec-00712 Wall-Mount Cabinets ROTEK ingle-door and Double-Hinged Cabinets ROTEK ingle-door, UL and NEMA Type 4, 12 INDUTRY TANDARD UL 508A Listed; ile Number E61997 cul Listed per CA C22.2 No. 94; ile

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

Safety Mats & Area Guarding

Safety Mats & Area Guarding Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

Featured Products - RU Marking Standard on Hoffman brand

Featured Products - RU Marking Standard on Hoffman brand : Open Frame Racks CHAPTER Open frame racks are versatile solutions for mounting hubs, switches, routers and servers. Easy access to all sides simplifies maintenance and updates. Solidly constructed, Pentair

More information

10 Pg C1 - C-30.qxp 6/9/ :43 AM Page C1. BELL Weatherproof Boxes, Covers, and Lighting

10 Pg C1 - C-30.qxp 6/9/ :43 AM Page C1. BELL Weatherproof Boxes, Covers, and Lighting 10 Pg C1 - C-30.qxp 6/9/2008 10:43 AM Page C1 BELL Weatherproof Boxes, Covers, and Lighting 10 Pg C1 - C-30.qxp 6/9/2008 10:43 AM Page C2 C2 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ pí~åç~êçë _Éää Δ

More information

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

Square D Homeline Load Centers and Circuit Breakers. Engineered for value Square D Homeline Load Centers and Circuit Breakers Engineered for value TM From the Square D brand you know and trust, Homeline Load Centers are engineered for value, reliability, and innovation. The

More information