EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY"

Transcription

1 EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL

2 EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk screws x Diode and x Capacitor Optional Accessories EVBPSBB Lock Power Supply EV-EXIT Push to Release EV-EBG Emergency Release EV-ML-50/500XT Electro-magnetic Lock ENTERD Electric Lock

3 EZTAG Manual.qxp_Layout 0/0/06 :7 Page Contents Installation EZTAG Wiring Example EZTAG Wiring Example Advanced Guide How to set-up Access Pin How to set-up Access Tags Deleting Access Pin or Tag Changing Pin Clear all Pin and Tag Data Default to Factory Settings Lock Output Operating Time Enable Door Bell Facility Enable Tamper Alarm facility Access Pin for Lock Output Deleting Access Pin for Lock Lock Output Operating Time for Lock Output System setup record User Guide Technical Specification

4 EZTAG Manual.qxp_Layout 0/0/06 :7 Page Installation Release hex screw from the bottom of the keypad (Side View) Push the keypad up to release from mount plate Thread system cable through the cable entry hole then make the system connections (as per the wiring diagram), mount the bracket to the surface and slide the keypad to the mountplate, re-fit the hex screw to secure into position. Note: if using more than one keypad, ensure that the keypads are mounted a minimum 85cm apart

5 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 5 EZTAG Wiring Example LEDs Capacitor for Electro-magnetic lock Diode for Electronic Lock Electro-magnetic lock _ + Electronic lock Lock -release time Red Black Green Purple Grey Pink NC + _ + _ N.C for Electro-magnetic lock N.O for Electronic lock Tag Reader EZTAG Wiring Example LEDs Red Black Green Purple Blue Grey Orange Pink Green/White N.O Purple/White COM Blue/White N.C Yellow White Tag Reader Input DC: +V - +V or Input AC: V - V N.O COM P.b for Lock (N.O) Output for Lock (Volt-free) N.C + _ Output for Lock (Volt-free) Push button for Lock (N.O) Speaker connection for door bell facility (8 0.5w recommended) 5

6 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 6 How to set-up Access Pin 9 0 a starting location number Double 5???? a digit pin ( not be used) 6 How to set-up Access Tags a unused location number* ??? number of tags to be registered 6 Present the tag with the lowest serial number 7 All other batch tags will auto register end programming *Each tag will use up a location number 6

7 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 7 Deleting Access Pin or Tag the location number of tag/pin 9 9 delete Changing Pin???? new digit programming pin???? Re-enter new digit programming pin 5 Note; access keypad s programming mode, the digit programming code is entered in twice 7

8 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 8 Clear all Pin and Tag Data Default to Factory Settings

9 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 9 Lock Output Operating Time number of seconds 00-99?? Enable Door Bell Facility 0 enable 0 disable Becomes the door bell push in normal mode 9

10 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 0 Enable Tamper Alarm facility 6 0 enable 0 disable Tamper alarm activates the keypad s internal buzzer and door bell output if the light sensor is exposed Access Pin for Lock Outputt 9 0 an unused location number Double 5???? a digit pin ( should not be used) 6 0

11 EZTAG Manual.qxp_Layout 0/0/06 :7 Page Deleting Access Pin for Lock the location number of pin delete Lock Output Operating Time for Lock Output 5 number of seconds 00-99??

12 EZTAG Manual.qxp_Layout 0/0/06 :7 Page assist in future programming, it is recommended that a record is made of the system setup. System Location ( ) Tag Serial Tag Owner Notes

13 EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Location ( ) Tag Serial Tag Owner Notes

14 EZTAG Manual.qxp_Layout 0/0/06 :7 Page User Guide release Lock access programming mode (A) a programmed Access Pin number (B) Present a registered tag Technical Specification DC input - volts AC input - volts Standby current 80ma Operating current (without lock) 0ma Working temperature -0c to +50c Reader frequency 5KHz IP rating 65 Dimension 50 x x mm

15 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 5 5

16 EZTAG Manual.qxp_Layout 0/0/06 :7 Page 6 Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN Telephone: Fax: E&OE - Errors and omissions excepted. L5

APWIFIDS WI-FI DOOR STATION

APWIFIDS WI-FI DOOR STATION APWIFIDS WI-FI DOOR STATION www.espuk.com J2474 ESP Instruction Manual APWIFIDS.indd 1 15/03/2017 11:20:14 System Overview Sunshield Optional accessories: IR LED Camera lens EVBPSBB Lock power supply Speaker

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

VIDI-AC-2CS Access Controller/ Reader

VIDI-AC-2CS Access Controller/ Reader VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

A P M O N W G A P M O N B G - C O L O U R V I D E O D O O R E N T R Y M O N I T O R U S E R M A N U A L. w w w. e s p u k. c o m

A P M O N W G A P M O N B G - C O L O U R V I D E O D O O R E N T R Y M O N I T O R U S E R M A N U A L. w w w. e s p u k. c o m PMONG Manual.qxp_Layout 1 28/01/2016 11:44 Page 1 P M O N W G P M O N G - O L O U R V I D E O D O O R E N T R Y M O N I T O R U S E R M N U L w w w. e s p u k. c o m PMONG Manual.qxp_Layout 1 28/01/2016

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

CC Series metal access control Manual

CC Series metal access control Manual CC Series metal access control Manual 1.Description CC Series is a standalone for two doors, support card, pin, card+pin access way. It is with 2 relays to control 2 doors and supports up to 2000 users

More information

CM-500 SK 500 USER CODES KEYPAD

CM-500 SK 500 USER CODES KEYPAD CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage

More information

PRODUCT GUIDE FT-DC3-HC DOCUMENT NUMBER REVISION DATE

PRODUCT GUIDE FT-DC3-HC DOCUMENT NUMBER REVISION DATE PRODUCT GUIDE DOCUMENT NUMBER REVISION DATE 20170822 NOTICE The manufacturer will accept no responsability for any electrical damage resulting from improper installation of this product, be that either

More information

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

WELCOME. For customer support or any inquiries, please visit our web site at  or contact us at WELCOME Congratulations on purchasing the GBF Smart Four Wire Intercom System. Our factory engineers were the first to enable multiple security cameras being monitored through a smart mobile device and

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook

More information

CA111x-series Arming Station

CA111x-series Arming Station GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4

More information

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44 AC-Q4x Family Vandal Resistant Stand-Alone controllers Instruction Manual ls: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44 December 2006 Table of Contents Table of Contents 1. General Information...

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

TABLE OF CONTENT. Ver1.01 Date : BRIEF INTRODUCTION NOTICE ACCERSSORYS HOW TO PLAY METER BOARD...

TABLE OF CONTENT. Ver1.01 Date : BRIEF INTRODUCTION NOTICE ACCERSSORYS HOW TO PLAY METER BOARD... TABLE OF CONTENT Ver1.01 Date :2011-4-8 1. BRIEF INTRODUCTION... 1 2. NOTICE... 1 2-1. SAFTTY INSTRUCTIONS... 1 2-2. OPERATION INSTRUCTION... 1 3. ACCERSSORYS... 1 4. HOW TO PLAY... 2 5. TECHNICAL PARAMETERS...

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

Rapid deployment surveillance system

Rapid deployment surveillance system Rapid deployment surveillance system Table of contents Camera Kit Contents... 2 System Requirements and Compatibility... 3 General Information... 3 Battery Life... 3 Quick Start Guide... 4 Camera Overview...

More information

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11. Intelligent IP Access Control Reader Installation Guide EN 101.00.XPS2 V1.11 www.supremainc.com Important Safety Information Carefully review the information within the user manual before installing or

More information

NS1 Connection Unit Guide

NS1 Connection Unit Guide PURPOSE AND APPLICATION Connection Unit Guide The connection unit is an installation friendly device, which makes it possible to use all features from a central unit. The CU can also be used to connect

More information

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT.  07/04 INSTRUCTION MANUAL 1 2 3 4 5 6 7 8 9 0 # PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT www.rosslaresecurity.com 0706-0960050-00 07/04 Contents INTRODUCTION 4 Technical Specifications 5 Key Features 6 INSTALLATION

More information

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide ZAVIO Outdoor IR Mini Dome Quick Installation Guide 0 Quick Installation Guide Please follow the installation steps below to set up your IP Camera. Check the package contents with the list below. See P.1

More information

IP Speaker System. Users Guide

IP Speaker System. Users Guide ii3-ess IP Speaker System Users Guide ESS User Manual This page intentionally left blank 2 ESS User Manual Table of Contents Overview... 1 Specifications... 2 25/70 Volt Lines... 3 Speaker Configurations...

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

MS-7000: SuperStar Reader

MS-7000: SuperStar Reader The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

YM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number

YM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number Contrast Sensor YM24PAH2ABF Part Number High switching frequency Small light spot Time delay can be activated LASER Technical Data Optical Data Range 150 mm Adjustable Range 60...150 mm Switching Hysteresis

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information

Proximity Card and Pin Reader Installation Manual

Proximity Card and Pin Reader Installation Manual Multi Prox Proximity Card and Pin Reader Installation Manual PUBLICATION INFORMATION 60A9 - Draft Release Version 0.1.2 71D0 - Version 1.0.5 CONTENTS Introduction... 1 Legend... 2 Terminology... 2 Mounting...

More information

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage

More information

Aceprox FSK Proximity Reader REV2 Data Sheet

Aceprox FSK Proximity Reader REV2 Data Sheet Aceprox 688-52 FSK Proximity Reader REV2 Data Sheet Overview The 688-52 OEM proximity reader consists of three parts: a potted unit containing the electronics, a front cover, and an optional spacer plate.

More information

TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24

TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24 TKL19 (RTUL19) Installation Manual Tema1.0_L19_IM_1.0_EN Pagina 1 di 24 CONTENTS 1.1 Wall Set Up for the Cable Trays... 3 1.2 Electrical Connections... 4 1.3 LONWORKS Data Cables... 6 1.4 Mounting the

More information

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual ls: AC-Q41H/HB AC-Q41HP AC-Q41SB AC-Q42H/HB AC-Q42HP AC-Q42SB AC-Q44 Copyright 2014 by Rosslare. All rights reserved.

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

ComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A...

ComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A... Electronics & Software ComoNeo System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications Type 5887A... ComoNeo is a process monitoring system made by Kistler that

More information

Keypad KEY-2.7. Instruction Manual

Keypad KEY-2.7. Instruction Manual Keypad KEY-2.7 Instruction Manual Precautions 2 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Never

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

installation quick guide integrated access control & environmental monitoring

installation quick guide integrated access control & environmental monitoring installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical

More information

INSTALLATION GUIDE Xpass English Version 2.00 EN XPS V2.00A

INSTALLATION GUIDE Xpass English Version 2.00 EN XPS V2.00A www.supremainc.com INSTALLATION GUIDE English Version 2.00 EN 101.00.XPS V2.00A Contents Safety Instructions... 3 Getting Started... 4 Components... 4 Features... 5 Part names and features... 5 Cables

More information

iloq S10 Online Configuration Guide

iloq S10 Online Configuration Guide iloq S10 Online Configuration Guide Document version: 1.5 (Updated 02 May 2017) Contents 1 S10 Online System... 3 1.1 Printable Documentation... 4 1.2 Licenses...4 1.3 Net Bridge N100...4 1.3.1 Net Bridge

More information

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998 SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch

More information

X6 Access Control. System User Manual

X6 Access Control. System User Manual X6 Access Control System User Manual 1.Equipment Installation Wall mount installation (1)Remove the screw on the bottom of device. (2)Take away the back cover. (3)Fix the back cover on the wall according

More information

PRODUCT GUIDE HC1151A DOCUMENT NUMBER REVISION DATE

PRODUCT GUIDE HC1151A DOCUMENT NUMBER REVISION DATE PRODUCT GUIDE DOCUMENT NUMBER REVISION DATE 20161024 NOTICE The manufacturer will accept no responsability for any electrical damage resulting from improper installation of this product, be that either

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX MODEL NUMBER: MDR900-5-0-GB-XX MDK900-5-0-GB-XX MULTI-DISCIPLINE SPECIFICATIONS Read Capability... READERS ImproX Multi-discipline Readers INSTALLATION MANUAL Slim Tags, Omega Tags, Impro Trinary Tags,

More information

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices Section A3 This Price Schedule is effective January 1, 2018. Date Page Comment 1-1-18 All January, 2018 Price Schedule update. 3-21-18 21 Added 1804-701, 1804-705, 1804-706 LED retrofit kits. 4-24-18 25

More information

Agility Installation Quick Start Guide 1

Agility Installation Quick Start Guide 1 Agility Installation Quick Start Guide Thank you for purchasing the Agility Flexible Wireless Solution from RISCO Group. This quick start guide will describe the main steps for installing and programming

More information

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping Features Frequency hopping between 433.10 to 434.70MHz 12-way dipswitch or encrypted coding Momentary and latching modes are

More information

Local Set Point Module Operating Bulletin

Local Set Point Module Operating Bulletin Local Set Point Module Operating Bulletin 1 Notice: The manufacturer reserves the right to make any changes and improvements to the products described in this manual at any time and without notice. This

More information

Inclinometer. 4-20mA and RS232

Inclinometer. 4-20mA and RS232 Inclinometer 4-20mA and RS232 Real size Main Features - Two axis digital inclinometer n - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Active linearization and temperaturecompensation

More information

MLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL

MLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL MLC 420 MAGNETIC Press Brake ENCODERS NON-CONTACT INTEGRATED BEARING SYSTEM USER SELECTABLE REFERENCE POSITION LEFT OR RIGHT MOUNTING HIGH RESOLUTION FROM 0.005mm HIGH PROTECTİON AGAİNST VIBRATION IP67

More information

P6210 PN: 86085A A

P6210 PN: 86085A A P6210 1 PN: 86085A1000010 86085A1000000 Zavio P6210 Quick Installation Guide Please follow the installation steps below to set up P6210 Pan/Tilt IR Dome IP Camera. Check the package contents against the

More information

SECURITY HARDWARE AND CABLES... Insulation Tape 20m x 18mm White. Insulation Tape - 20m x 18mm White Nitto. Cable Tie Large 395 x 4.

SECURITY HARDWARE AND CABLES... Insulation Tape 20m x 18mm White. Insulation Tape - 20m x 18mm White Nitto. Cable Tie Large 395 x 4. Insulation Tape 20m x 18mm White General insulation tape for all electrical applications Fire retardant 0.18mm x 18mm x 20m CA26 Insulation Tape - 20m x 18mm White Nitto High quality electrical insulation

More information

Simple Card Reader for Door Access & Time Attendance System. User Guide

Simple Card Reader for Door Access & Time Attendance System. User Guide Simple Card Reader for Door Access & Time Attendance System User Guide 3 CHAPTER 1 GETTING STARTED Viewing the User Guide in the Internet Included Accessories Included Printed Materials Activating m-kadex

More information

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data Publication January 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com

More information

PIM Presco Interface Module

PIM Presco Interface Module INTRODUCTION The Interface Module (PIM) can be used to convert commonly used data formats to Nidac, or format data. PIM Interface Module Series 2 Revision B FEATURES Converts from,, Nidac, Clock & Data

More information

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated: Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect

More information

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have. Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom

More information

Enclosures for Remote I/O System I.S. 1

Enclosures for Remote I/O System I.S. 1 STAINLESS STEEL (V2A) STAINLESS STEEL (V4A) POLYESTER RESIN IP66 For Installation in II 2 G EEx e II Increased safety protection Certified according to 94/9EG (ATEX) For Installation in Zone 2 Declaration

More information

EN FULL DETAILS. SKR Vandal Resistant keypad Full Details. Passion.Technology.Design.

EN FULL DETAILS. SKR Vandal Resistant keypad Full Details. Passion.Technology.Design. EN FULL DETAILS SKR Vandal Resistant keypad Full Details Passion.Technology.Design. Warnings When installing the apparatus, please respect to the letter all instructions provided by the supplier and in

More information

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry 36 Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry Assembly Assembly of modular terminal blocks to terminal strips Mounting of an end plate screw fixing CAGE

More information

Fingerprint Door Lock OPERATOR S MANUAL

Fingerprint Door Lock OPERATOR S MANUAL Fingerprint Door Lock OPERATOR S MANUAL Notes: Please read this manual carefully before operation. 1 Contents Chapter 1: Introduction 03 1.1 Features 03 1.2 Technical Specification 03 1.3 Fingerprint recognition

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1. Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation

More information

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome GV-IPCam H.264 Hardware Manual Vandal Proof IP Dome Target Vandal Proof IP Dome Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future

More information

Fingerprint Door Lock User MANUAL

Fingerprint Door Lock User MANUAL Fingerprint Door Lock User MANUAL Notes: Please read this manual carefully before operation. 0 User Manual AKME LOCK LLC Contents CHAPTER 1: INTRODUCTION... 2 1.1 FEATURES... 2 1.2 TECHNICAL SPECIFICATION...

More information

OFP401P0189. Color Sensor. Operating Instructions

OFP401P0189. Color Sensor. Operating Instructions OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection

More information

DIGITAL 2 WIRE SYSTEM

DIGITAL 2 WIRE SYSTEM DIGITAL 2 WIRE SYSTEM NEW PRODUCTS 2 WIRE SYSTEM EXTENSIONS The apartment interface allows the extension and personalisation of the installation from within the dwelling The installation expansion module

More information

TABLE OF CONTENT 1. BRIEF INTRODUCTION NOTICE ACCESSORIES HOW TO PLAY TECHNICAL PARAMETERS METER BOARD...

TABLE OF CONTENT 1. BRIEF INTRODUCTION NOTICE ACCESSORIES HOW TO PLAY TECHNICAL PARAMETERS METER BOARD... TABLE OF CONTENT Ver1.46 Date : 2014-7-17 1. BRIEF INTRODUCTION... 2 2. NOTICE... 2 2-1. SAFTTY INSTRUCTIONS...2 2-2. NOTICE FOR OPERATION...2 3. ACCESSORIES... 2 4. HOW TO PLAY... 3 5. TECHNICAL PARAMETERS...

More information

GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS

GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS 333 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 R GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS Napco 2004 WI1221A

More information

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx Vending Machine Card Reader Module Model: CRM-170-xx Version C (26/08/05) Contents Section Title Page 1 Component Layout 3 2 Cables 6 2.1 Executive Power 6 2.2 Executive Data - External 6 2.3 Executive

More information

M-PROX2 Installation Instructions

M-PROX2 Installation Instructions M-PROX Installation Instructions Section General Description The M-PROX (CV-60) is a door access control system. It has inputs for HID/AWID proximity readers, Form C relay outputs for connection to electrified

More information

iclock serial Time & Attendance and Access Control Terminal Installation Instructions

iclock serial Time & Attendance and Access Control Terminal Installation Instructions iclock serial Time & Attendance and Access Control Terminal Installation Instructions About this Guide This guide provides installation instructions only. For information regarding actual operation and

More information

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements Allegion Schlage AD-300 networked, hardwired locks can be integrated seamlessly with the Doors.NET software when used with the NXT-MSC (Mercury-Powered controllers). You can connect and communicate with

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H) AR- (H) / AR- (H)/ AR-(H) / AR- (H) / AR- (H) SOYAL ACCESS CONTROL SYSTEM V0 Contents AR- (H):Touch-panel Metal Housing Product User Guide Terminal Cables Tools Water proof Strip d x P P P P AR- (H):Touch-panel

More information

Wireless Digital Video Doorbell

Wireless Digital Video Doorbell Wireless Digital Video Doorbell User s Manual Door Camera Indoor Handset Remark Please follow the user manual for correct installation and testing, if there is any doubt, please call our tech-supporting

More information

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio

More information

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013 AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA

More information

AHD 4CH HDD MOBILE DVR

AHD 4CH HDD MOBILE DVR AHD 4CH HDD MOBILE DVR Hardware User Manual (Nysus 6 & 7) 0 Catalogue Chapter 1 Accessories and Interface... 1 1.MDVR and accessories... 1 2.System connection... 2 3.Panel introduction... 3 4.Interfaces

More information

Draw wire sensors, draw wire sensors for displacement, position

Draw wire sensors, draw wire sensors for displacement, position Draw wire sensors, draw wire sensors for displacement, position Sensors based on potentiometer and encoder, for industrial and OEM applications for measurement of lengths, stroke, displacement, position,

More information

alarm shop WEATHERPROOF, MULLION MOUNT ACCESS CONTROL READER KEYPAD DK-2890 Programming & Installation Manual RoHS Compliance

alarm shop WEATHERPROOF, MULLION MOUNT ACCESS CONTROL READER KEYPAD DK-2890 Programming & Installation Manual RoHS Compliance WEATHERPROOF, MULLION MOUNT ACCESS CONTROL READER KEYPAD RoHS Compliance WITH APO DATA I/O PORT DK-2890 Programming & Installation Manual FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT-ON

More information

INSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A

INSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A www.supremainc.com INSTALLATION GUIDE English Version 2.10 EN 101.00.BEW V2.10A Contents Safety Instructions... 3 Getting Started... 4 Components... 4 Features... 5 Part names and features... 5 Cables

More information

05/11/2012 Ins-30202 Net2 Entry - Monitor Paxton Technical Support 01273 811011 support@paxton.co.uk Technical help is available: Monday - Friday from 07:00-19:00 (GMT) Saturday from 09:00-13:00 (GMT)

More information

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ ) e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ 18990-04) Table of Contents Introduction... 1 e-fob Operation and

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

Wing Watch Lite. Battery Monitoring System. User Manual

Wing Watch Lite. Battery Monitoring System. User Manual Wing Watch Lite Battery Monitoring System User Manual February 2009 Check the contents: The Wing Watch-Lite is packed in soft, protective material inside a carton box. There are 5 sets in each packaging.

More information

F & SC Serial Access Control Station. Installation Guide

F & SC Serial Access Control Station. Installation Guide F & SC Serial Access Control Station Installation Guide About this Guide The F&SC Access Control Station User guide is designed to provide information to install the F& SC serial Access Control Station,

More information

WiFi Wireless Video Door Phone. User Manual

WiFi Wireless Video Door Phone. User Manual WiFi Wireless Video Door Phone User Manual Introduction With Hisilicon Hi3518E hardware platform, this WIFI/IP video intercom doorbell uses H.264 image compression. Its picture transmission data is small

More information

SELECTOR 4 / 8. Instrument for torque control ASL 11/17

SELECTOR 4 / 8. Instrument for torque control ASL 11/17 Instrument for torque control SELECTOR 4 / 8 ASL 11/17 3000840 ENGLISH Pictograms WARNING It can be dangerous to use this machine if the operating instructions are not carefully followed. Before using

More information

ATP1000 Touchpad/Display Installation Instructions

ATP1000 Touchpad/Display Installation Instructions ATP1000 Touchpad/Display Installation Instructions Product summary The ATP1000 lets you control all programming and operation of compatible security systems (see the Specifications section). The large

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic

More information

AUDIO AND VIDEO KITS SECTION CONTENTS 66

AUDIO AND VIDEO KITS SECTION CONTENTS 66 66 SECTION CONTENTS 68 General features Catalogue 70 Audio kits 74 Video colour kits 76 Video black and white kits 77 Video black and white kits with memory COMMUNICATION GENERAL CATALOGUE 07/08 67 Audio

More information