3RP, 7PV Timing Relays
|
|
- Jeffry Gilbert
- 6 years ago
- Views:
Transcription
1 3RP, PV Timing Relays Overview Standards The timing relays comply with: EN "Environmental conditions" EN /DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN and EN "Electromagnetic compatibility" EN ; (VDE 0660 Part 200) "Low-voltage controlgear, switchgear and systems Electromechanical controlgear" 3RP15 timing relays, width Application Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings. Enclosure design All timing relays are suitable for snap-on mounting onto 35 mm standard mounting rails according to EN or for screw fixing. LED for indicating "Time relay on voltage" LED for indicating "Relay switched" range selector switch Function switch Decive labeling plate NSB0_01423 Operating time adjustment Inspection window for set time range Inspection window for set function Accessories Push-in lugs for screw mounting Sealable cap Label set for marking the multifunction relay /28 Siemens LV
2 Selection and ordering data mechanical engineering with: 1 changeover or 2 changeover s Rated control supply voltage U s DT Screw-type connection PU V V kg 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Indicator labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. 1) 1 CO, s 8 functions 2 CO s, 16 functions 3RP B... 2 CO s, positively driven and hard goldplated. 8 functions 4)5) 3RP15 1. timing relays, ON-delay, 1 time setting range 1 CO A 3RP AA unit / } 3RP AQ unit / } 3RP AP unit ) ) } 3RP AW unit / } 3RP BQ unit / } 3RP BP unit ) ) } 3RP BW unit A 3RP BT unit } 3RP RW unit / } 3RP AQ unit / } 3RP AP unit / } 3RP AQ unit / } 3RP AP unit / } 3RP AQ unit / } 3RP AP unit RP A... 3RP15 25 timing relays, ON-delay, 15 time setting ranges 3RP A... 1 CO s 2 CO s / / 3RP15 2 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO (semiconductor) s s s 24/ } 3RP AQ unit / } 3RP AP unit ) A 3RP BR unit / } 3RP BQ unit / ) 24 } 3RP BP unit ) } 3RP BW unit ) A 3RP15 2-1EC unit ) } 3RP15 2-1EM unit RP15 2-1E... 1) For functions, see 3RP label set. 2) With switch position Š, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0. to 1.1 x U s. 4) Positively driven: NO and NC are never closed simultaneously; gap >= 0.5 mm is ensured, minimum make-break capacity 12 V, 3 ma. 5) The changeover s are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous ). 6) Operating range 0.8 to 1.1 x U s. Siemens LV /29
3 mechanical engineering with: 1 changeover or 2 changeover s Rated control supply voltage U s DT Spring-loaded terminal PU V V kg 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Indicator labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. 1) 1 CO, s 8 functions 2 CO s, 16 functions 2 CO s, positively driven and hard goldplated. 8 functions 4)5) 3RP15 1. timing relays, ON-delay, 1 time setting range 1 CO 24/ C 3RP AQ unit / A 3RP AP unit ) ) A 3RP AW unit / A 3RP BQ unit / A 3RP BP unit ) ) A 3RP BW unit A 3RP RW unit / C 3RP AQ unit / A 3RP AP unit / C 3RP AQ unit / A 3RP AP unit / C 3RP AQ30 1 unit / C 3RP AP unit RP15 25 timing relays, ON-delay, 15 time setting ranges 1 CO s 24/ C 3RP AQ unit / A 3RP AP unit CO s 24/ C 3RP BQ unit / A 3RP BP unit ) ) A 3RP BW unit RP15 2 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO s ) C 3RP15 2-2EC unit (semiconductor) s ) C 3RP15 2-2EM unit s 1) For functions, see 3RP label set. 2) With switch position Š, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0. to 1.1 x U s. 4) Positively driven: NO and NC are never closed simultaneously; gap >= 0.5 mm is ensured, minimum make-break capacity 12 V, 3 ma. 5) The changeover s are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous ). 6) Operating range 0.8 to 1.1 x U s. /30 Siemens LV
4 mechanical engineering with: 1 changeover or 2 changeover s Rated control supply voltage U s DT Screw-type connection PU V V kg 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range 1 CO The same potential must be applied to terminals A and B. 24/ A 3RP AQ unit / } 3RP AP unit / A 3RP AQ unit / } 3RP AP unit / A 3RP AQ unit / } 3RP AP unit RP A... 3RP15 40 timing relays, OFF-delay, without auxiliary voltage, time setting ranges 1) 1 CO s s s ) } 3RP AB unit ) } 3RP AJ unit ) } 3RP AN unit CO s ) } 3RP BB unit ) A 3RP BJ unit ) } 3RP BN unit RP A... 3RP15 55 timing relays, clock-pulse relay, 15 time setting ranges s / / 1 CO 60 5) A 3RP AR unit / } 3RP AQ unit / } 3RP AP unit RP A... Š 4) 3RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range 3 NO s 3) (common root terminal 1) wye-delta s, overtravel time (idling) s 24/ A 3RP SQ unit / } 3RP SP unit RP S... 3RP15. timing relays, wye-delta function 6), dead interval 50 ms, 1 time setting range 1 NO s 24/ } 3RP15 4-1NQ unit instantaneous and 24/ } 3RP15 4-1NP unit NO / -- B 3RP15 4-1NM unit delayed (common s 24/ } 3RP15 6-1NQ unit root terminal 1) 24/ } 3RP15 6-1NP unit / -- B 3RP15 6-1NM unit RP15.-1N... 1) Setting of output s in as-supplied state not defined (bistable relay). Application of the control voltage once results in changeover to the correct setting. 2) Operating range 0. to 1.25 x U s. 3) Operating range 0.85 to 1.1 x U s. 4) With switch position Š, no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x U s. 6) For typical circuit see Schematics. Siemens LV /31
5 mechanical engineering with 1 changeover or 2 changeover s Rated control supply voltage U s DT Spring-loaded terminal PU V V 1) Setting of output s in as-supplied state not defined (bistable relay). Application of the control voltage once results in changeover to the correct setting. 2) Operating range 0. to 1.25 x U s. 3) Operating range 0.85 to 1.1 x U s. 4) With switch position Š, no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x U s. 6) For typical circuit see Schematics. per unit/ set/ meter 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range 24/ C 3RP AQ unit CO 24/ A 3RP AP unit The same 24/ C 3RP AQ unit potential must 24/ C 3RP AP unit be applied to terminals A and 24/ C 3RP AQ unit B 24/ C 3RP AP unit RP15 40 timing relays, OFF-delay, without auxiliary voltage, time setting ranges 1) 1 CO s s s ) A 3RP AB unit ) A 3RP AJ unit ) A 3RP AN unit CO s ) A 3RP BB unit ) C 3RP BJ unit ) C 3RP BN unit RP15 55 timing relays, clock-pulse relay, 15 time setting ranges s / /60 5) C 3RP AR unit changeover 24/ C 3RP AQ unit Š 4) 24/ A 3RP AP unit RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range wye-delta s, overtravel time (idling) s 3RP15. timing relays, wye-delta function 6), dead interval 50 ms, 3 NO s 3) (common root terminal 1) 1 time setting range 1 NO instantaneous and 1 NO delayed (common root terminal 1) 24/ C 3RP SP unit s 24/ A 3RP15 4-2NP unit / B 3RP15 4-2NM unit s 24/ C 3RP15 6-2NQ unit / A 3RP15 6-2NP unit / B 3RP15 6-2NM unit kg /32 Siemens LV
6 Accessories Label sets Function Code letter Application Accessory for 3RP (not included in the scope of supply). The label set offers the possibility of labeling timing relays with the set function in English and German. With ON-delay A for B 1 label set OFF-delay with auxiliary voltage (1 unit) with 8 ON-delay and OFF-delay with functions auxiliary voltage Flashing, starting with interval Passing make Passing break with auxiliary voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage With ON-delay A for B 1 label set OFF-delay with auxiliary voltage (1 unit) with 16 ON-delay and OFF-delay with functions auxiliary voltage Flashing, starting with interval Passing make Passing break with auxiliary voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage and instantaneous ON-delay and instantaneous OFF-delay with auxiliary voltage and instantaneous ON-delay and OFF-delay with auxiliary voltage and instantaneous Flashing, starting with interval, and instantaneous Passing make and instantaneous Passing break with auxiliary voltage and instantaneous Pulse-forming with auxiliary voltage and instantaneous C D E F H C D E F H A B C D E F G with 1 CO and 3RP RW30 with 2 CO s DT Order No. Price PU kg } 3RP A 1 5 units } 3RP B 1 5 units Wye-delta function *D Blank labeling plates Blank labeling plates, mm x mm, pastel turquoise 1) C 3RT SB units Covering caps and push-in lugs Push-in lugs for screw mounting for with 1 or 2 CO s } 3RP units Sealable caps for securing against unauthorized adjustment of setting knobs for with 1 or 2 CO s } 3RP units ) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV /33
3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationSolid-State Switching Devices
Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data
More informationSIRIUS 3RB2 Solid-State Overload Relays
SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationElectrical Components for the Railway Industry. SIRIUS Relays 3RP, 3RS, 3TX
Electrical Components for the Railway Industry SIRIUS Relays 3RP, 3RS, 3TX www.siemens.com/railway-components SIRIUS Relays Introduction SIRIUS Relays Introduction Page 2 SIRIUS Relays Introduction Timing
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationIndustrial Controls. Time Relays. SIRIUS 3RP25 Time Relays. Gerätehandbuch. Answers for industry. Edition 10/2014
Industrial Controls Time Relays SIRIUS Gerätehandbuch Manual Edition 10/2014 Answers for industry. Introduction 1 Safety notes 2 SIRIUS Monitoring and control devices Manual Description 3 Mounting 4 Connection
More informationSIRIUS - SIRIUS 3RA28
Industrial Controls Switching Devices SIRIUS - SIRIUS 3RA28 Function modules for mounting on 3RT2 contactors Gerätehandbuch Manual Edition 09/2016 siemens.com SIRIUS - SIRIUS 3RA28 function modules for
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationRelays. SIRIUS 3RR24 Monitoring Relays for Mounting onto 3RT2 Contactors for IO-Link. Current and active current monitoring. 10/80 Siemens IC
SIRIUS 3RR24 Monitoring for Mounting onto 3RT2 Contactors for IO-Link Current and active current monitoring Benefits Can be mounted directly on 3RT2 contactors and 3RA23 reversing contactor assemblies,
More informationMonitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview
Siemens AG 2010 Overview Benefits Can be used without auxiliary voltage in any network from 160 to 600 V AC worldwide thanks to wide voltage range Variably adjustable to overvoltage, undervoltage or range
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More informationData sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307
CI-TI TM Contactors and Motor Starters August 2002 DKACT.PD.C00.J2.02 520B1307 Introduction or - star-delta start Multi function electronic timers featuring: - ON delay - OFF delay - single pulse pause
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description
(-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase
More informationElectronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet
2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationAS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45
Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationOverload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview
Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationSiemens AG up to 12 up to 25 up to 50 up to 100 up to 200 up to S12 Terminal brackets for stand-alone
Siemens G 2007 Protection Equipment Introduction Type 3RU11 3RB20 3RB21 3RB22/3RB23 Overload relays up to 630 pplications System protection 1) 1) 1) 1) Motor protection lternating current, 3-phase lternating
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationElectronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet
CDC 51 1 F000 1 7 6 5 8 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 00 h, for the adjustment of the pulse time c/o contacts nd c/o contact can be
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet
2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication
More informationSR60 Busbar System 2/1. 2/2 Busbar routing. 2/3 Mounting components. 2/6 Accessories
SR60 Busbar System 2 2/2 Busbar routing 2/3 Mounting components 2/6 Accessories 2/1 SR60 Busbar System Busbar routing SR60 Busbar System Dimensions Order No. Price PG Weight PS*/ W x H x D mm mm mm 1 item
More informationElectronic timer CT-ERS.21
2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width
More informationControls Solid-State Switching Devices
Siemens AG 27 Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Relays /6 General data /7 3RF21 solid-state relays, single-phase, 22.5 mm
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More informationSafety Relays 3TK2845 Multifunction Device
Important Information, Table of Contents Product Description 1 Safety Relays 3TK2845 Multifunction Device Functional Information 2 Technical Data 3 Mounting, Wiring, Initial Start-up 4 Manual Applications
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2234992 (012730_C_000) Date ssued: 2017-08-04 ssued to: Siemens AG DF CP R&D C 2 Werner-von-Siemens-Strasse 48 Amberg, 92224 GERMANY The products listed below are
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationControl relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO
Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating
More informationIndustrial Controls Product Catalog 2017
Industrial Controls Product Catalog 2017 SIRIUS Section c o n t e n t s Thermal overload relays Solid state overload relays OVERLOAD RU21 overload relays up to 100 A with screw connection, CLASS 10 Page
More informationLoad Feeders, Motor Starters and Soft Starters
Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationElectronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet
2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)
More informationElectronic timers CT range
Electronic timers CT range ABB electronic timers CT range For many years, ABB s CT range electronic timers has been used in applications worldwide and has proven its excellent functionality in daily use
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationIEC Power Control Overload Relays
IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU21 overload relays up to 100 A with screw connection, CLASS 10 Page Selection and ordering data
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationElectronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationElectronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control
More informationIEC Power Control Overload Relays
IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU11 / 3RU1 overload relays up to 100 A with screw connection, CLASS 10 Page 3RB4 overload relays
More informationElectronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet
Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 0 South nd Street Milwaukee, WI 504 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,
More informationElectronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationElectronic timer CT-AHD.22
2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More informationDatasheet - SLB 200-C04-1R
14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety
More informationMulti Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC
DIN Timers TD 22.5mm DIN rail mounting Electronic Timers AC/DC coil operation Multi-time range Multi-function, On-delay, Off-delay and Star/Delta versions Voltage range selectable Marking plate cover Y
More informationIndustrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,
Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,
More informationElectronic time relays ATI, BTI, SDT and MTI
MAKING MODERN LIVING POSSIBLE Technical brochure Electronic time relays ATI, BTI, SDT and MTI With their robust design and many built-in functions, electronic timers ATI, BTI, SDT and MTI are ideal for
More informationSwitching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors
7/4 Product overview 7/5 5TT5 remote control switches 7/8 5TT3 0 switching relays 7/9 5TT5 7 Insta contactors 7/10 5TT3 4 Soft-starting devices 7/11 5TT5 2 EMERGENCY-STOP modules 5 7 8 9 10 12 13 7/1 When
More information4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data
Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed
More informationElectronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers
More informationU1602, U1603 ENERGY CONTROL SYSTEM
3-349-046-03 3/6.09 64 processing channels physical inputs or LON meter outputs can be assigned for the calculation of energy, power and costs Energy Control Language for the programming of analysis, monitoring
More informationOffering you the latest innovative products & solutions from Siemens. au.rs-online.com
Offering you the latest innovative products & solutions from Siemens au.rs-online.com Need a quote? YOU WILL GET EXTRA SAVING EVERY TIME WITH OUR QUOTATION SERVICE. There is no need for you to spend time
More informationStandards and approvals
2 SIRIUS controls contactors and contactor assemblies 4 SIRIUS controls solid-state switching devices 4 SIRIUS protective devices 8 SIRIUS load feeders and compact starter 12 SIRIUS Circuit Breaker 12
More informationTeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters
Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp
More informationIf something has to be monitored: A relay for every application. simirel
If something has to be monitored: A relay for every application simirel Time Relays Time Relays 3RP15/3RP20 for snapping onto mounting rails 4/5 7PV for front-panel mounting, digital 6/7 Temperature Monitoring
More informationA2000 Multifunctional Power Meter
3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationict contactors EN 61095, IEC 1095 Interference
ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.
More informationComponents for Distribution Systems
Components for Distribution Systems /2 Introduction Busbar adapter systems /4 General data /7 40 mm system / 60 mm system /12 Accessories /14 Project planning aids Door-coupling rotary mechanisms /23 General
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationZelio Time - timing relays
Presentation Zelio ime - timing relays DIN rail mounted relays Presentation A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationSIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED
SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationSolid-State Switching Devices
Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching
More informationENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm
ENERGY SAFELY SWITCHED SWITCHGEAR BUSBAR SYSTEM 60 mm SWITCHGEAR ENERGY safely switched About Grupa Apator Who we are? Grupa Apator is a dynamic Polish capital group, it currently includes 14 companies
More informationElectrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA
for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA
More informationElectronic timer CT-ERD.12
2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationRE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O
Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More informationALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationSITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3
Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact The CT-ERS.12 is an electronic timer from the CT-S range with ON-delay and 10 time ranges. All electronic timers from the CT-S
More informationPhone: Fax: Web: -
In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. The controller monitors
More informationRMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B
3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationRZ7-FE Electronic Timing Relays
Electronic Timing Relays The economical choice for most industrial timing applications precher + chuh s electronic timing relays offer seven popular output functions in an economical package. This series
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More information5SL Miniature Circuit Breakers
5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens
More informationDatasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10
General Description Room Control Unit RCU Series are designed as an all in one product for different room layouts such as apartments, hotel rooms, hospitals and residences. Available versions of EAE RCU
More informationElectronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and
More information