RSS Series Wired Electronic Ballasts

Size: px
Start display at page:

Download "RSS Series Wired Electronic Ballasts"

Transcription

1

2 RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz No. of Lamp Circuits Min. For 800mA T12/HO Standard Open Circuit For use with T12 HO, T8 HO, and Slimline 208/220/240/277/347 Volts, 50/60Hz Wiring Diagram 1 to 2 Circuit I (lamps 1,2) 4' 16' RSS296AT* 120V ,2 2 to 4 4 to 6 Circuit I (lamps 1,2) Circuit I (lamps 1,2,3) 4' 12' 16' 24' Circuit II (lamps 3,4) Circuit II (lamps 4,5,6 ) 4' 12' 16' 24' RSS496AT** RSS696AT*** 120V 120V to 6 Circuit I (lamps 1,2,3) 8' 24' Circuit II (lamps 4,5,6) 8' 24' RSS L*** 120V No. of Lamp Circuits Min. For 800mA T8/HO Standard Open Circuit Wiring Diagram 1 to 2 Circuit I (lamps 1,2) 4' 12' RSS296AT 120V ,2 2 to 4 4 to 6 Circuit I (lamps 1,2) Circuit I (lamps 1,2,3) 4' 9' 12' 18' Circuit II (lamps 3,4) Circuit II (lamps 4,5,6 ) 4' 9' 12' 18' RSS496AT RSS696AT 120V 120V to 6 Circuit I (lamps 1,2,3) 8' 18' Circuit II (lamps 4,5,6) 8' 18' RSS L 120V No. of Lamp Circuits Min. For 800mA T12/HO Standard Open Circuit Wiring Diagram 208V to 2 Circuit I (lamps 1,2) 4' 16' RSS296AT V* 277V ,2 347V V Circuit I (lamps 1,2) 4' 16' 2 to 4 RSS496AT V** 277V Circuit II (lamps 3,4) 4' 16' 347V V Circuit I (lamps 1,2,3) 12' 24' 4 to 6 RSS696AT V*** 277V Circuit II (lamps 4,5,6) 12' 24' 347V V Circuit I (lamps 1,2,3) 8' 24' 2 to 6 RSS L V*** 277V Circuit II (lamps 4,5,6) 8' 24' 347V

3 RSS Specifications Charts Continued No. of *For use with 1 10 lamp. **For use with 2 10 lamps. ***For use with 4 10 lamps. RSS Ballast Chart CAT# T8/T12 # of lamps RSS296AT RSS296AT V Lamp Circuits T8 1-2 T Min. 1 For 800mA T8/HO Standard Open Circuit Wiring Diagram 208V to 2 Circuit I (lamps 1,2) 4' 12' RSS296AT V 277V ,2 347V V Circuit I (lamps 1,2) 4' 12' 2 to 4 RSS496AT V 277V Circuit II (lamps 3,4) 4' 12' 347V V Circuit I (lamps 1,2,3) 9' 18' 4 to 6 RSS696AT V 277V Circuit II (lamps 4,5,6) 9' 18' 347V V Circuit I (lamps 1,2,3) 8' 18' 2 to 6 RSS L V 277V Circuit II (lamps 4,5,6) 8' 18' 347V Total Lamp Range (Feet) RSS296AT (T8) RSS296AT (T12) RSS496AT RSS496AT V T8 2-4 T RSS496AT (T8) RSS496AT (T12) RSS696AT RSS696AT V T8 4-6 T RSS696AT (T8) RSS696AT (T12) RSS L RSS L V T8 2-6 T RSS696AT (T8) RSS696AT (T12) Dimensions and Weights CAT # Lead Length (Feet) Black White / White Orange/ Tan RSS296AT / RSS296AT V RSS496AT / RSS496AT V RSS696AT / RSS696AT V RSS L / RSS L V CAT # Dimensions (Inches) Weight Length Width Height Mounting (lb) RSS296AT / RSS296AT V 11-3/4 3-3/16 1-3/4 11-1/8L x 2 W 5 RSS496AT / RSS496AT V 16-5/8 3-3/16 2-5/ /16 L x 2 W 10 RSS696AT / RSS696AT V 16-5/8 3-3/16 2-5/ /16 L x 2 W 10 RSS L / RSS L V 16-5/8 3-3/16 2-5/ /16 L x 2 W 10 / Black L Top View Slot Mounting (W) Side View H Mounting (L) 3

4 RSS Installation Wiring Diagrams DIAGRAM 1 DIAGRAM 2 DIAGRAM 3 1-Lamp Combination 2-Lamp Combination 2-Lamp Combination /White DIAGRAM 4 DIAGRAM 5 DIAGRAM 6 3-Lamp Combination /White 4-Lamp Combination /White /White 4-Lamp Combination Orange Orange/Black Lamp 4 Lamp 4 DIAGRAM 7 DIAGRAM 8 /White 5-Lamp Combination Orange Orange/Black /White 6-Lamp Combination Orange Orange/Black Insulate each unused wire separately where indicated on all wiring diagrams. Lamp 4 Lamp 5 Lamp 4 Lamp 5 Lamp 6 RSS Diagrams can easily be used in both new installation and magnetic to electronic replacement applications. All ballasts must be grounded. DIAGRAM 9 DIAGRAM 10 /White 2-Lamp Combination Orange Orange/Black /White 3-Lamp Combination Orange Orange/Black 4

5 EESB Parallel Wired s Specifications Charts EESB Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz No. of Min. For 800mA T12/HO Standard Open Circuit Wiring Diagram 1 18" 8' EESB L 120V ,7 1 to 3 4' 24' EESB L 120V ,9 1 to 6 8' 32' EESB L 120V ,10 1 to 4 10' 40' EESB L # 120V ,11 2 to 6 10' 48' EESB L ### 120V ,12 For use with T12 HO, T8 HO, and Slimline 120/220/240/277 Volts, 50/60Hz No. of Min. 1 to 6 2' 50' For 800mA T12/HO Standard 120V EESB L V 208V V V V EESB L V 208V V V V EESB L V ## 208V V V V EESB L V # 208V V V Open Circuit 1 to 2 2' 16' to 4 4' 32' 2 to 6 10' 48' Wiring Diagram 2,8 5,11 6,12 6,12 For use with T12 HO, T8 HO, T8 50K hours Long Life, and Slimline 120/220/240/277 Volts, 50/60/Hz No. Of 1 to 6 Min. 2' 50' For 315mA T8 Long Life Lamp Open Circuit Wiring Diagram 120V V EESB L V 980 6,12 240V V For use with up to 4 10 lamps ## For use with up to 5 10 lamps ### DO NOT use 10 lamps Wiring Diagrams: Located on page 6. Diagram references in charts above indicate wiring for maximum loading. All EESB Ballasts Above: Single lamp per circuit 8 maximum, Multiple lamps per circuit 7 maximum, except where specified up to 10 lamps. 5

6 EESB Parallel Wired s For use with T12 HO, T8 HO, T8 18K hours Medium Life, and Slimline 120/220/240/277 Volts, 50/60/Hz No. Of Min. 1 to 2 2' 12' For 375mA T8 HO Medium Life 120V EESB L V 208V V V V EESB L V 208V V V V EESB L V 208V V V V V V V Open Circuit For use with T12 HO, T8 HO, and Slimline 208/220/240/277/347 Volts, 50/60Hz Wiring Diagram 1 to 4 4' 24' 980 5,11 1 to 6 2' 48' 2 to 6 10' 48' EESB L V # 980 6,12 For T12/HO No. Of Open Circuit Cat # Min. Wiring Diagram 208V to 3 4' 24' EESB MV 240V V ,9 347V V to 6 8' 32' EESB MV 240V V ,10 347V V to 4 10' 40' EESB MV # 240V V ,11 347V V to 6 10' 48' EESB MV 240V V ,12 347V #For use with up to 4 10 lamps Wiring Diagrams: Located on page 6. Diagram references in charts above indicate wiring for maximum loading. All EESB Ballasts Above: Single lamp per circuit 8 maximum, Multiple lamps per circuit 7 maximum, except where specified up to 10 lamps ,8 6,12

7 EESB Parallel Wired s EESB Ballast Chart CAT # EESB L T8/T12 # of lamps T8 1 T Total Lamp Range (Feet) EESB L (T8) EESB L (T12) EESB L EESB MV T8 1-3 T EESB L / EESB MV (T8) EESB L / EESB MV(T12) EESB L EESB MV T8 1-6 T EESB L /EESB MV(T8) EESB L/EESB MV (T12) EESB L EESB MV T8 1-4 T EESB L /EESB MV(T8) EESB L/EESB MV(T12) EESB L EESB MV T8 2-6 T EESB L /EESB MV(T8) EESB L /EESB MV(T12) EESB L V T8 1-2 T EESB L V (T8) EESB L V (T12) EESB L V T8 1-4 T EESB L V (T8) EESB L V (T12) EESB L V T8 1-6 T T8 Long Life 1-6 EESB L V (T8) EESB L V (T12) EESB L V (T8 Long Life) EESB L V T8 2-6 T EESB L V (T8) EESB L V (T12) Dimensions and Weights CAT # Lead Length (Feet) Dimensions (Inches) Weight Black White Length Width Height Mounting (lb) EESB L /2 2-3/8 1-5/8 8-7/8 L x 1.7 W 2 EESB L EESB MV / /4 11-1/8 L x 2.0 W 5 EESB L EESB MV / /4 13-3/4 L x 2.0 W 8 EESB L EESB MV / /4 13-3/4 L x 2.0 W 8 EESB L EESB MV / /4 13-3/4 L x 2.0 W 8 EESB L V /2 2-3/8 1-5/8 8-7/8 L x 1.7 W 2.5 EESB L V / /4 13-3/4 L x 2.0 W 9.5 EESB L V / /4 13-3/4 L x 2.0 W 8 EESB L V / /4 13-3/4 L x 2.0 W 9 L Top View Slot Mounting (W) Side View H Mounting (L) 7

8 EESB Parallel Wired s EESB New Installation Wiring Diagrams DIAGRAM 1 DIAGRAM 2 DIAGRAM 3 DIAGRAM 7 DIAGRAM 8 DIAGRAM 9 DIAGRAM 4 DIAGRAM 5 DIAGRAM 6 DIAGRAM 10 DIAGRAM 11 DIAGRAM 12 Wiring diagrams for Allanson Lighting Components' EESB s are simpler, with half the connections found in old-style magnetics. are parallel wired, so if one burns out the others keep working. All ballasts must be grounded. uce 1 foot when combined with multiple lamps. 8

9 EESB Parallel Wired s EESB Magnetic to Electronic Re-Wiring Diagrams DIAGRAM 1 DIAGRAM 2 EESB L (2-LAMP MAGNETIC TO ELECTRONIC) EESB L (3-LAMP MAGNETIC TO ELECTRONIC) White Black 2-Lamp Magnetic Ballast White Black 3-Lamp Magnetic Ballast /White /White DIAGRAM 3 DIAGRAM 4 EESB L & EESB L (4-LAMP MAGNETIC TO ELECTRONIC) EESB L/ V, EESB L, & EESB L (6-LAMP MAGNETIC TO ELECTRONIC) 4-Lamp Magnetic Ballast Lamp 4 /white Orange/Black Orange 6-Lamp Magnetic Ballast Lamp 4 Lamp 5 /White Lamp 6 Symbol indicates to join two lamp socket wires together and then to connect to one wire (blue or red). Symbol indicates cutting of jumper wires to disconnect the parallel connection of lamp sockets. For a live demonstration, watch our Magnetic to Electronic Replacement Video. Visit 9

10 Fluorescent H.O. Lamp Holders Tombstone Lamp Holders Flush Mount Lamp Holders Lamp holder Ratings: 660W, 600V / 1000V rating Materials: GE resins, Ni plated steels, stainless steels, O ring, and tin bronze contacts were used in the manufacturing of Allanson lamp holders. The 12 lead assemblies are stranded 18AWG tinned copper and have 1015/1032 UL ratings 221 F (105 C) and 1000V. Mounting: High strength metal retaining clips ensure solid hold when installed per specifications. Mounting D Hole: culus listed. UL listed for use in U.S.A and Canada. 10

11 Fluorescent Ballast Cross Reference Chart Magnetic Ballasts Electronic Replacement Allanson Universal France Advance Transco RSS EESB T AT DR --- TRA ' - 4' RSS296AT EESB L / EESB L V 196-AT DR " - 8' RSS296AT EESB L 224-AT DR --- TRA ' - 4' RSS296AT EESB L V ' - 4' RSS296AT EESB L V 272-AT DR ASB BL-TP TRA ' - 12' RSS296AT EESB L / EESB L V 296-AT DR --- TRA ' - 16' RSS296AT EESB L / EESB L V 348-AT DR --- TRA ' - 12' --- EESB L 372-AT DR ' - 18' --- EESB L DR --- TRA ' - 20' RSS496AT EESB L / EESB L V 396-AT DR --- TRA ' - 24' RSS496AT / RSS L EESB L / EESB L V 448-AT DR ASB BL-TP TRA ' - 16' RSS496AT EESB L / EESB L V ' - 24' RSS496AT / RSS L EESB L / EESB L V 472-AT DR ASB BL-TP TRA ' - 24' RSS496AT / RSS L EESB L / EESB L V 496-AT DR ASB BL-TP TRA ' - 32' RSS496AT / RSS L EESB L / EESB L V 4120-AT DR ASB BL-TP TRA ' - 40' RSS696AT / RSS L EESB L / EESB L V 572-AT DR ' - 30' RSS696AT / RSS L EESB L / EESB L V 648-AT DR --- TRA ' - 24' --- EESB L / EESB L V 672-AT DR ASB BL-TP TRA ' - 36' RSS696AT / RSS L EESB L / EESB L V 696-AT KR ASB BL-TP TRA ' - 48' RSS696AT / RSS L EESB L / EESB L V 148-AT-277V KR ' - 4' RSS296AT V EESB L V 196-AT-277V KR " - 8' RSS296AT V AT-277V KR ' - 12' RSS296AT V EESB L V 296-AT-277V KR ' - 16' RSS296AT V EESB L V 348-AT-277V KR ' - 12' --- EESB L V 372-AT-277V KR ' - 18' --- EESB L V 396-AT-277V KR ' - 24' RSS496AT V / RSS L V EESB L V 448-AT-277V KR ' - 16' RSS496AT V EESB L V 472-AT-277V KR ' - 24' RSS496AT V / RSS L V EESB L V 496-AT-277V KR ' - 32' RSS496AT V / RSS L V EESB L V 4120-AT-277V KR ' - 40' RSS696AT V / RSS L V EESB L V 572-AT-277V KR ' - 30' RSS696AT V / RSS L V EESB L V 648-AT-277V KR ' - 24' --- EESB L V 672-AT-277V KR ' - 36' RSS696AT V / RSS L V EESB L V 696-AT-277V KR ' - 48' RSS696AT V / RSS L V EESB L V 148-AT-347V ' - 4' RSS296AT V AT-347V " - 8' RSS296AT V AT-347V ' - 12' RSS296AT V AT-347V ' - 16' RSS296AT V AT-347V ' - 12' --- EESB MV 372-AT-347V ' - 18' --- EESB MV 396-AT-347V ' - 24' RSS496AT V / RSS L V EESB MV 448-AT-347V ' - 16' RSS496AT V EESB MV 472-AT-347V ' - 24' RSS496AT V / RSS L V EESB MV 496-AT-347V ' - 32' RSS496AT V / RSS L V EESB MV 4120-AT-347V ' - 40' RSS696AT V / RSS L V EESB MV 572-AT-347V ' - 30' RSS696AT V / RSS L V EESB MV 648-AT-347V ' - 24' --- EESB MV 672-AT-277V ' - 36' RSS696AT V / RSS L V EESB MV 696-AT-347V ' - 48' RSS696AT V / RSS L V EESB MV *EESB L V Ultimate Ballast Replaces all models listed. 11

12 #

RSS Series Wired Electronic Ballasts

RSS Series Wired Electronic Ballasts RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz Per Circuit Combined

More information

RSS Series Wired Electronic Ballasts

RSS Series Wired Electronic Ballasts REV 02/16 RSS Series Wired s Specifications Charts RSS Installation Wiring Diagrams RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline

More information

RSS Series Wired Electronic Ballasts

RSS Series Wired Electronic Ballasts RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz RSS Installation

More information

EESB Parallel Wired Electronic Ballasts

EESB Parallel Wired Electronic Ballasts EESB Parallel Wired s Specifications Charts EESB Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz No. of For 800mA

More information

HOW TO READ AN ELECTRONIC SIGN

HOW TO READ AN ELECTRONIC SIGN ELECTRONIC SIGN Ballasts CONTENTS 208 209 209 210 211 211 How To Read a Table T8/HO Sign Ballasts T12/HO Sign Ballasts Case Dimensions and Wiring Diagrams Cross Reference Guide Lamp Compatibility Specifications

More information

AllPro Hazardous/Corrosive Area Fluorescent

AllPro Hazardous/Corrosive Area Fluorescent CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - 4X UL 844 - Class I Div. 2 - Groups A, B, C, & D UL 4X UL - Outdoor

More information

One Phase Power Distribution Block

One Phase Power Distribution Block Quick mounting and wiring Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm) Accessories increase the number of outputs with only one input (applies only to and ) No caps

More information

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors

More information

A3000, LP3000 & CB3000

A3000, LP3000 & CB3000 A3000, LP3000 & CB3000 Dimensions Inches (Millimeters) A3000 & LP3000 A31930307 LP307102 Specifications Rating: A3: 30A, 600V* LP3: 30A, 150V* CB3: 30A, 600V* Wire Range: #12-22 AWG Cu Center Spacing:

More information

Male connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting

Male connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting Male connector; with fixing flanges; 6-pole; pin spacing 508 mm / 02 in; for screw or similar mounting types; for parallel or perpendicular mounting Item No: 231-636/019-000 Male connector; with fixing

More information

VersaPro Non-Metallic Fluorescent

VersaPro Non-Metallic Fluorescent CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Class III CSA - Type 3 R Enclosed & Gasketed Features: Non-Metallic Fluorescent

More information

Terminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks

Terminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks Series A3000, LP3000 & CB3000 Single Row Terminal SPECIFICATIONS Rating: A3: 30A, 600V* #12-22 AWG LP3: 30A, 150V #12-22 AWG CB3: 30A, 600V #12-22 AWG Wire Range: #12-22 AWG CU Center Spacing: 0.437 or

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

Max. Input Power (W) Input Current. Inrush Current

Max. Input Power (W) Input Current. Inrush Current Output Power (W) Output Voltage (V) Output Current (A) Efficiency Tcase Max Input Current Max. Input Power (W) Inrush Current (Apk/µs) Max. THD (%) Min. Power Factor Surge Protection (KV) Weight (Lbs)

More information

NEW. Datasheet. WMF 2.5 Terminal Series

NEW. Datasheet. WMF 2.5 Terminal Series Datasheet WMF 2.5 Terminal Series NEW The WMF 2.5 (multi-functional) terminal series is uniquely designed for DCS marshalling where increased functionality, improved spacing, higher wiring density and

More information

A2000, LP2000 & CB2000

A2000, LP2000 & CB2000 A2000, LP2000 & CB2000 Dimensions Inches (Millimeters) A2000 & LP2000 A203504 LP201204 Specifications Rating: A2: 30A, 300V* LP2: 30A, 150V* CB2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range:

More information

A0 & CB0. Single Row Terminal Blocks. Dimensions- Inches (Millimeters) Specifications CB0

A0 & CB0. Single Row Terminal Blocks. Dimensions- Inches (Millimeters) Specifications CB0 A0 & CB0 Dimensions- Inches (Millimeters) A0 0.12 (3.0) Ø A00110407 0.250 (6.35) Specifications Rating: 10 A, 300 V Center Spacing: 0.25 (6.35 mm) Wire Range: #16-30 AWG Screw Size: M3.0 nickel-plated

More information

Terminal Blocks - Single Row. Series A2000, LP2000 & CB2000 Single Row Terminal Blocks

Terminal Blocks - Single Row. Series A2000, LP2000 & CB2000 Single Row Terminal Blocks Series A2000, LP2000 & C2000 Single Row Terminal A20510807WR SPECIFICATIONS Rating: A2: 30A, 300V* LP2: 30A, 150V* C2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range: #12-22 AWG CU Screw Size:

More information

Bulletin 855E 50 mm Control Tower Stack Lights

Bulletin 855E 50 mm Control Tower Stack Lights Bulletin 855E 50 mm Control Tower Stack Lights Light Modules Sound Modules Flashing Incandescent 855E 10 FN 4 Voltage Light Module Type Lens Color 00 0 250V AC/DC (no lamp module) (1) XN Steady no lamp

More information

Electrical Interconnection

Electrical Interconnection Electrical Interconnection Edition 208/ Rail-Mount Terminal Block Systems Full Line Catalog, Volume Edition 207/208 PCB Terminal Blocks and Connectors Full Line Catalog, Volume 2 Edition 207/208 2 Automation

More information

Diffuser Color (when not illuminated) Light amber hue

Diffuser Color (when not illuminated) Light amber hue PRODUCT SUMMARY PRODUCT FEATURES Four Kelvin temperatures Energy efficient Long lifetime Stable and consistent color temperature Low voltage Easy to install Cool to the touch For use as exterior or interior

More information

LED-HCNA-0024V-41-F-L-O

LED-HCNA-0024V-41-F-L-O Electrical Specifications LED-HCNA-0024V-41-F-L-O Output Power (W) Output Voltage (V) Output Current (A) Tcase Max Input Current (A) Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power

More information

Bulletin 700-HL 2-Pole Terminal Block Relay

Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal

More information

ITS-Z0344 Half Pitch Interface Connectors

ITS-Z0344 Half Pitch Interface Connectors All non- product have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website search at www.hirose-connectors.com, or contact your Hirose sales representative.

More information

www.greenelectricalsupply.com Page 1 of 4 DESCRIPTION Replacement for Conventional T12HO and T8HO Fluorescent Lamps for Sign Applications APPLICATION Used for Outdoor Signage (Single or Double Sided) PRODUCT

More information

Terminal Blocks - Single Row. Series A2000, LP2000 & CB2000 Single Row Terminal Blocks. Terminal Blocks: Single Row. EuroMag Series.

Terminal Blocks - Single Row. Series A2000, LP2000 & CB2000 Single Row Terminal Blocks. Terminal Blocks: Single Row. EuroMag Series. Series A2000, LP2000 & C2000 Terminal locks A201108WR SPECIFICATIONS Rating: A2: 30A, 300V* LP2: 30A, 150V* C2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range: #12-22 AWG Cu Screw Size: #6-32

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Output Power (W) Output Voltage (V) Output Current (A) Tcase Max Input Current (A) Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power Factor Surge Protection (KV) Weight (Lbs) Envir.

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE / 2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power

More information

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry 36 Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry Assembly Assembly of modular terminal blocks to terminal strips Mounting of an end plate screw fixing CAGE

More information

Plexineon Color Series

Plexineon Color Series PRODUCT SUMMARY PRODUCT FEATURES Bright, even-toned color Durable construction Long life Energy efficient Low voltage Easy to install Cool to the touch For use as exterior or interior accent lighting,

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS LIGHTING WARNING -Installation must only be performed by a licensed electrician. -To prevent death, injury or damage to property this product must be installed in accordance to

More information

FDS / FDS-R / FDS-PS

FDS / FDS-R / FDS-PS FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of

More information

Model Number AC-60CD1.4APPU

Model Number AC-60CD1.4APPU ELECTRICAL SPECIFICATIONS: Programmable, Digital, Wide-Range Ajustable Current & Dimming Class P Listed Constant Current LED Driver Model Number AC-6CD.4APPU Input Voltage: 2-277V Input Frequency: 5/6Hz

More information

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075

More information

NT-2300 Series Dual Circuit Track System & Accessories

NT-2300 Series Dual Circuit Track System & Accessories ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated

More information

Cat.8 Shielded Keystone Jack Description

Cat.8 Shielded Keystone Jack Description Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor

More information

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire

More information

Cat. No. (Spring Clamp. Input Voltage

Cat. No. (Spring Clamp. Input Voltage Bulletin -HL Product Overview/Product Selection Product Selection Bulletin -HL "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications

More information

industrial panel lamps

industrial panel lamps features specifications Typical characteristics (Ta = C) Ø8.1mm mounting Robust bright nickel plated brass housing Low profile styling, sunlight readable LEDs Sealed to IP67 Internal reverse protection

More information

Item No.: /

Item No.: / Angled female connector; with snap-in mounting foot; 3-pole; pin spacing 5 mm / 097 in; 00% protected against mismating; for panel mounting; Plate thickness 06x2 mm; Fixing holes 35 mm Ø Item Angled female

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor with Cable Amplifier Offers Greater Mounting Flexibility Programmable Controller-compatible Subminiature, shielded sensing head (3 or 8 dia.) allows the Sensor

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

RJHS Series. RJ vistatm. EMI Quiet Modular Jacks with LED s. Specifications. Ordering Information EMI QUIET - WITH LEDS

RJHS Series. RJ vistatm. EMI Quiet Modular Jacks with LED s. Specifications. Ordering Information EMI QUIET - WITH LEDS EMI Quiet Modular Jacks with LED s is a family of EMI Quiet Modular Jack Connectors with built-in LEDs, meets Ethernet CAT 5 performance. This product is ideal for LAN applications such as adapter cards

More information

Principal LED Street Stik Fluorescent Bulb Replacements

Principal LED Street Stik Fluorescent Bulb Replacements Principal LED Street Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

A2, LP2 & CB2. Single Row Terminal Blocks. Dimensions Inches (Millimeters) Specifications A2 & LP2 CB2

A2, LP2 & CB2. Single Row Terminal Blocks. Dimensions Inches (Millimeters) Specifications A2 & LP2 CB2 A2, LP2 & CB2 Dimensions Inches (Millimeters) A2 & LP2 LP201204 A203504 Specifications Rating: A2: 30A, 300V* LP2: 30A, 150V* CB2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range: #12-22 AWG

More information

A006 LuxStrip II 6 Line

A006 LuxStrip II 6 Line DATA SHEET Page 1 of 6 Product Overview The LuxStrip II A006 is a powerful compact light engine built on a Printed Circuit Board (PCB) and thermally engineered to accommodate high brightness LEDs. Utilizing

More information

SBE 80 / SBO 60 Connectors - up to 80 Amps

SBE 80 / SBO 60 Connectors - up to 80 Amps Connectors - up to 80 Amps SBE and SBO connectors build on the capability of the two pole SB connectors by offering up to 8 auxiliary power / signal contacts along with an IEC 60950 touch safe housing.

More information

Principal LED Qwik Stik Fluorescent Bulb Replacements

Principal LED Qwik Stik Fluorescent Bulb Replacements Principal LED Qwik Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

Max. Input Power (W) Inrush Current (A pk /µs) LED ARRAY

Max. Input Power (W) Inrush Current (A pk /µs) LED ARRAY Electrical Specifications LEDINTA0024V41DLO Max. Power (W) Voltage (V) Current (A) Tcase Max Input Current (A) Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power Factor Surge Protection

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

Case Expansion Transducer Systems

Case Expansion Transducer Systems Case Expansion Transducer Systems Product Datasheet Bently Nevada* Asset Condition Monitoring Description Thermal Case Growth Measurements in Large Turbines An important position measurement in Turbine

More information

D10CC150HV10F. HRV ( V) Dimmable LED Driver 1050mA, Constant Current Output 0 10V Dimming to 10% Thermal Foldback Control.

D10CC150HV10F. HRV ( V) Dimmable LED Driver 1050mA, Constant Current Output 0 10V Dimming to 10% Thermal Foldback Control. HRV (347 480V) Dimmable LED Driver 1050mA, Constant Current Output 0 10V Dimming to 10% Thermal Foldback Control Performance Input Voltage 347 ~ 480 Vac ± 10% Input Current Max 0.48 /347V 0.34/480V Input

More information

REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS

REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS The e-con standard was developed in Japan in 2001 by a group of Japanese manufacturers in order to standardize connections from sensors to terminals.

More information

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: DOC0067 Issue 1.2 Reader Wiring InSTRUCTIONS SP1 MP1 WP2 WP1 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: MP1-EM1 MP1-HT1 MP1-DP1 WP1-EM1 WP1-HT1

More information

FT & RT Test Switches

FT & RT Test Switches GE Grid Solutions FT & RT Test Switches Key Benefits The FT Switches and FT Test Plugs have all the features necessary for applications involving the measurement of individual currents and voltages to

More information

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features Super Manual Fiber Amplifier Adjuster type standard that is the culmination of true ease and simplicity Features Self-explanatory LED bar displays of light levels The previous manual type used the stability

More information

KM025B Series. Features. Application. 025 ( 0.64 mm ) / Standard. Rev. 002 (' ) 1. 표준소형커넥터제품 2. 강화된체결음, 커넥터삽입력을만족한감성품질이우수한커넥터

KM025B Series. Features. Application. 025 ( 0.64 mm ) / Standard. Rev. 002 (' ) 1. 표준소형커넥터제품 2. 강화된체결음, 커넥터삽입력을만족한감성품질이우수한커넥터 Features 1. 표준소형커넥터제품 2. 강화된체결음, 커넥터삽입력을만족한감성품질이우수한커넥터 3. 자동차의소형, 경량화요구에대응한제품 4. 세경전선에대응가능한 W/H 작업성구현 5. 신소재를적용하여외부온도및충격에의한제품파손을개선 Application 1. Switch Unit, Heater Control Unit, Cluster, AVN etc 차량용

More information

7.92 mm Contact Pitch, High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed)

7.92 mm Contact Pitch, High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed) NEW 7.9 mm Contact Pitch, High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed) DF Series Complete Locking Function Completely enclosed locking system Protection from shorts circuits

More information

Chemical Resistant Inductive Prox

Chemical Resistant Inductive Prox Chemical Resistant Inductive Prox Fluoroplastic Housing Sensor Performs Accurately Under Harsh Environmental Conditions Full body resin housing and nuts resist weld spatter Rugged watertight fluoroplastic

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m Through-Beam Sensor with Visible Red LED Visible Beam Allows Visual Confirmation of the Detection Spot, for Easy Installation and Maintenance Built-in amplifier Mutual interference protection filter included

More information

APPLICATION NOTES. Connectors for LED Lighting Applications. Co-Planar Board Mating FIG. 1

APPLICATION NOTES. Connectors for LED Lighting Applications. Co-Planar Board Mating FIG. 1 APPLICATION NOTES Connectors for LED Lighting Applications Mill-Max addresses the connector needs of the growing field of LED lighting applications with products such as receptacles and sockets suitable

More information

UTME 6. Extract from the online catalog. Order No.:

UTME 6. Extract from the online catalog. Order No.: Extract from the online catalog UTME 6 Order No.: 3047400 Test disconnect terminal block, Connection method: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG: 24-8, Width: 8.2 mm, Color: gray, Mounting

More information

Bulletin 871D Cylinder Position Inductive Style

Bulletin 871D Cylinder Position Inductive Style Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal

More information

Solid State Remote Power Controller E

Solid State Remote Power Controller E Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient

More information

GV-EL124S Electric Strike

GV-EL124S Electric Strike GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either

More information

90 Series (7.37mm) LED Panel Mount Indicator

90 Series (7.37mm) LED Panel Mount Indicator 90 Series 0 (7.37mm) Panel Mount ndicator 90 Series with built-in long life offer superior construction and longer life Cartridge, bi-pin and wire leads termination styles Key features uilt-in can be used

More information

Through-Board SMD PCB Terminal Block; 0.75 mm² Pin Spacing: 6.5 mm 2070 Series

Through-Board SMD PCB Terminal Block; 0.75 mm² Pin Spacing: 6.5 mm 2070 Series Volume, Section SMD PCB Terminal Blocks Through-Board SMD PCB Terminal Block; 0.75 mm² 070 Series SMD PCB terminal blocks with Push-in CAGE CLAMP connection for back-side wiring of LED modules Low profile

More information

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION POWERHOUSE TM -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION NCE Corporation 1260 CREEK STREET SUITE 100 WEBSTER NEW YORK 14580 FAX : (716) 671-9337 E-mail:

More information

Scout Select System White

Scout Select System White JOb Name : Fixture Type : one Engine - Three Intensities 2.5 5.0 10.0 2.5 Watts / Foot 180 Lumens / Watt 450 Lumens / Foot 5.0 Watts / Foot 150 Lumens / Watt 750 Lumens / Foot 10.0 Watts / Foot 120 Lumens

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/64 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

D2SW-3L1HS D2SW-01L1HS

D2SW-3L1HS D2SW-01L1HS Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures

More information

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover

More information

Compact Fluorescent Lampholders

Compact Fluorescent Lampholders Table of Contents GR14q 26.738 [03] 14, 15 GZ16q 26.739 [03] 16 G23 26.719 [03] 17-19 26.721 [03] 17, 18 GX23 / GX23-2 26.720 [03] 20, 21 Supports for TC-S lamps 26.719 [03] 22-24 G24 / GX24 26.745 [03]

More information

FOR PC BOARD TO FLAT CABLE

FOR PC BOARD TO FLAT CABLE AXM FOR PC BOARD TO FLAT CABLE MIL CONNECTORS (AXM) Density mounting Long lever type Short lever type Compliance with RoHS Directive FEATURES 1. High density mounting is possible. Even with mounting right

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Electrical Specifications LEDINTA0024V41FLO Output Power (W) 100 Output Voltage (V) 24 cv 3.5~24 cc Output Current (A) 0.10~4.16 cv 4.16 cc Tcase Max cv = constant voltage mode, cc = constant current mode

More information

Bulletin 854K 60 Mm Control Tower Stack Lights

Bulletin 854K 60 Mm Control Tower Stack Lights Bulletin 854K 60 Mm Control Tower Stack Lights UL Type 4/4X/13, IP66 "No tools" lens assembly Surface, vertical, M20 threaded tube, quick release base, 1/2 in. NPT, double-sided base, M12 (5-pin DC) micro

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

Switches and Indicators 84

Switches and Indicators 84 Switches and Indicators 84 84 Switches and Indicators Index Series 84 Description Page 177 Product Assembly Page 178 Mounting Instruction Page 179 Product Range - pushbuttons for flush mounting - accessories

More information

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30 Sensing distance Supply voltage Output 4 mm 8 mm 12 to 24 VDC 100 to 220 VAC 200 ma max. 100 ma max. Proximity Sensor Detects Objects without Being Influenced by Aluminum and Cast Iron Cut Chips Sense

More information

Through/Ground Conductor/Ex and Double-Potential Terminal Blocks 1 (1.5) mm, 2000 Series

Through/Ground Conductor/Ex and Double-Potential Terminal Blocks 1 (1.5) mm, 2000 Series 54 TOPJOB @ Through/Ground Conductor/Ex and Double-Potential Terminal Blocks (.5) mm, 2000 Series 0.4 - (.5) mm I N 3.5 A (8 A) AWG 24-00 V, 0 AU 00 V, 0 A2 Terminal block width 3.5 mm / 0.38 in L 9 -

More information

Bulletin 800Z Zero-Force Touch Buttons

Bulletin 800Z Zero-Force Touch Buttons Bulletin 800Z Zero-Force Touch Buttons IEC and NEMA Style General Purpose Range Heavy Industrial Range Protection Class 4/4X/3 and 4/3 IP66 Internationally Rated Ergonomically Designed Touch Buttons Table

More information

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Installation Manual - 5365-902 Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 1 of 7 MiniProx Reader

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

CF CARD CONNECTOR MA TYPE

CF CARD CONNECTOR MA TYPE CF Card 1.27mm (.5") pitch CF CARD CONNECTOR MA TYPE 5-circuit CF card connector Emboss Tape Features Socket Both dual-row straddle type and single-row SMT type sockets are available. Single-row SMT type

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

8 Series Pushbutton Switches

8 Series Pushbutton Switches 8 Series Pushbutton Switches Features. Contacts Silver or gold-plated contacts.. Epoxy resin case UL94V-0 self-extinguishing epoxy. 3. Actuator style Over 30 actuator variations. 4. Insulation between

More information

REMOTE HEAD ADAPTER INSTALLATION GUIDE

REMOTE HEAD ADAPTER INSTALLATION GUIDE REMOTE HEAD ADAPTER INSTALLATION GUIDE The Remote Head adapter is a valuable accessory for the Uniden BC-780, 785 and 796 scanners. It allows the scanner's control panel to be removed from the radio and

More information

PA FAMILY SERIES/PA PAF PAL CONNECTOR

PA FAMILY SERIES/PA PAF PAL CONNECTOR PA FAMILY SERIES/PA PAF PAL CONNECTOR.0mm pitch/wire-to-board (Crimp style/idc) / Wire-to-wire (Crimp style/idc) Based upon wire-to-board crimp style PA connectors, the PA series family of connector have

More information

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently

More information

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are Safety Relay Unit The G9SA Series Offers a Complete Line of Compact Units H Several types of -mm wide Units are available: a -pole model, a -pole model, models with poles and OFF-delay poles H 7.-mm wide

More information

Preliminary. Sensors. EasySense. Fixture-Mount for Networks

Preliminary. Sensors. EasySense. Fixture-Mount for Networks Sensors EasySense Fixture-Mount for Networks EasySense for networks is based on zigbee technology for use in wireless systems for indoor connected lighting. It provides a simple solution to actively manage

More information

EcoSystem Digital Ballasts

EcoSystem Digital Ballasts EcoSystem Digital s 369339f 1 06.04.12 EcoSystem compact ballasts provide high-performance dimming for any compact uorescent application, including within an EcoSystem Lighting Control System. EcoSystem

More information

CHANNEL LETTER LED MODULES ALPHAMAX SERIES

CHANNEL LETTER LED MODULES ALPHAMAX SERIES PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 5 CHANNEL LETTER LED MODULES PRODUCT DESCRIPTION: The LED AlphaMax Series offers a full range of two, three and four LED modules designed

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

Panasonic top level series with super panel and vigorous outlines bringing elegance to your everyday life. BS-TYPE

Panasonic top level series with super panel and vigorous outlines bringing elegance to your everyday life. BS-TYPE Panasonic top level series with super panel and vigorous outlines bringing elegance to your everyday life. 8 SURFACE ART AND SUPER-SLIM DESIGN Perfect asymmetric design along with high quality aluminum

More information

[.050 (1.27mm) Density. D-Microminiature]

[.050 (1.27mm) Density. D-Microminiature] Commercial [.050 (1.27mm) Density Solder Introduction Cup/Wire D-Microminiature] Cinch Commercial Products, consisting of Jones Plugs and Sockets, Barrier Blocks, Edge Cards, Two-Piece Commercial Dins,

More information