NB : NEW VAM and old VAM are interchangeable up to 9 5/8" size only. To get details, contact VAM Services at

Size: px
Start display at page:

Download "NB : NEW VAM and old VAM are interchangeable up to 9 5/8" size only. To get details, contact VAM Services at"

Transcription

1 SCOPE OF APPLICATION This specification gives the standard make-up torque values to be applied on NEW VAM connections. Values to be applied on standard connections or with special clearance SC and also with Matched strength MS and with the Resilient Seal RS option., VAM, VAM ATAC, VAM AF and VAM AG threads are all compatible. The following chart shows which optimum torque is applicable according to the previous connections. Pin Box M.S (1) VAM VAM ATAC VAM AG VAM AF M.S (1) VAM VAM ATAC SC VAM SC (2) (1) M.S matched Strength (2) S.C Special Coupling VAM AG VAM AF Minimum Torque Minimum Torque Minimum Torque Minimum Torque SC VAM SC (2) NB : and old VAM are interchangeable up to 9 5/8" size only. To get details, contact VAM Services at mr.help@vamservices.com. Torque revision 2.2 1

2 DOPE QUANTITY MINIMUM DOPE QUANTITY FOR MAKE - UP Nominal O.D. Dope volume (in.) (cm³) (in.³) 2 3/ / / / / / / / / / / / / / / The weight of dope to apply on a connection depends of the specific gravity of the used dope. For example, the make up dope quantity in 7" will be: 42*1.67=70g with a dope having a gravity of 1.67 g/cm 3 and 2.6*1.00=2.6 oz with a dope having a gravity of 1.00 oz/in 3. Torque revision 2.2 2

3 NOMI- WALL 55 ksi ksi 2 3/ 8" / 8" / 2" " / 2" Torque revision 2.2 3

4 NOMI- WALL 55 ksi ksi 5 " / 2" / 8" " Torque revision 2.2 4

5 NOMI- WALL 55 ksi ksi 7 5/ 8" / 4" / 8" / 8" / 8" Torque revision 2.2 5

6 NOMI- WALL 55 ksi ksi 10 3/ 4" / 4" / 8" / 8" / 8" Torque revision 2.2 6

7 NOMI- WALL ksi Ksi 2 3/ 8" / 8" / 2" " / 2" Torque revision 2.2 7

8 NOMI- WALL ksi Ksi 5 " / 2" / 8" " Torque revision 2.2 8

9 NOMI- WALL ksi Ksi 7 5/ 8" / 4" / 8" / 8" / 8" Torque revision 2.2 9

10 NOMI- WALL ksi Ksi 10 3/ 4" / 4" / 8" / 8" / 8" Torque revision

11 NOMI- WALL ksi Ksi 2 3/ 8" / 8" / 2" " / 2" Torque revision

12 NOMI- WALL ksi Ksi 5 " / 2" / 8" " Torque revision

13 NOMI- WALL ksi Ksi 7 5/ 8" / 4" / 8" / 8" / 8" Torque revision

14 NOMI- WALL ksi Ksi 10 3/ 4" / 4" / 8" / 8" / 8" Torque revision

15 NOMI- WALL ksi (OD) WEIGHT -NESS min. opti max. 2 3/ 8" / 8" / 2" " / 2" Torque revision

16 NOMI- WALL ksi (OD) WEIGHT -NESS min. opti max. 5 " / 2" / 8" " Torque revision

17 NOMI- WALL ksi (OD) WEIGHT -NESS min. opti max. 7 5/ 8" / 4" / 8" / 8" / 8" Torque revision

18 NOMI- WALL ksi (OD) WEIGHT -NESS min. opti max. 10 3/ 4" / 4" / 8" / 8" / 8" For some applications, some customers or end users need specific VAM connections. The TSLI 25X contains these specific connections and indicates whether the standard torques listed here below or special make-up torques listed on TSLI 457 have to be applied. Torque revision

Standard Releasing Spear. Manual B215

Standard Releasing Spear. Manual B215 Standard Releasing Spear Manual B215 NOTES Contents Standard Releasing Spear Overview... 2 Use... 2 Construction... 2 Illustrations Spear Assembly with Flush-Type Mandrel... 3 Spear Assembly with Shoulder-Type

More information

SYSTEMS ELECTRONICS GROUP

SYSTEMS ELECTRONICS GROUP SYSTEMS ELECTRONICS GROUP SYSTEMS M4500 MACHINE COMPONENTS RSV34-MS1 RESOLVER with MS CONNECTOR Brushless, Single-turn Resolver Rated to 3,000 RPM Rotary Position Transducer for M4500, M4020, M4040, M4041,

More information

Avtec, Inc. Lighting Systems

Avtec, Inc. Lighting Systems 6 Industrial Park Cahokia, IL 62206 Phone (618) 337-7800 Fax (618) 337-7976 E-Mail tech_info@avteclighting.com Report No. INSTALLATION OPERATION MAINTENANCE MANUAL, LED STRIP LIGHT, P/N 01-11-0010 P/N

More information

Hypermod Series. Heavy Duty Modular Connectors. Technical Characteristics

Hypermod Series. Heavy Duty Modular Connectors. Technical Characteristics Heavy Duty Modular Connectors Heavy duty modular rectangular connector for signal, power, fiber optics, databus and coaxial contacts. From 1 mm to 3.5 mm nominal pin DIA crimp contacts; 3, 5, 10 and 20

More information

Vibration Transducer SLD121 A

Vibration Transducer SLD121 A Vibration Transducer SLD2 A 4.8 23.5 24 40.5 5.5 The vibration transducer SLD2 A is a piezo-electric accelerometer of compression type with built-in preamplifier, designed for vibration monitoring of industrial

More information

Avtec, Inc. Lighting Systems

Avtec, Inc. Lighting Systems 6 Industrial Park Cahokia, IL 62206 Phone (618) 337-7800 Fax (618) 337-7976 E-Mail tech_info@avteclighting.com Report No. INSTALLATION OPERATION MAINTENANCE MANUAL, LED STRIP LIGHT, P/N 01-11-0007 P/N

More information

Title: Terms and Conditions for the Approval of Multiple Dimension Measuring Devices

Title: Terms and Conditions for the Approval of Multiple Dimension Measuring Devices Effective Date: 2006-03-16 Page: 1 of 8 Revision: 1.0 Application These terms and conditions apply to devices that measure the dimension and/or volume of objects by calculating the smallest cuboidal shape

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

Bus Capable. Compact. Flexible. WSG Intelligent Gripper

Bus Capable. Compact. Flexible. WSG Intelligent Gripper WSG Bus Capable. Compact. Flexible. WSG Intelligent Gripper Servo-electric 2-finger parallel gripper with highly precise gripping force control and long stroke Field of Application A ll-purpose, ultra-flexible

More information

Specification for SN Transceiver Receptacle Rev 1.0 Feburary 12 th, 2019

Specification for SN Transceiver Receptacle Rev 1.0 Feburary 12 th, 2019 Specification for SN Transceiver Receptacle Rev 1.0 Feburary 12 th, 2019 Abstract: This specification defines the fiber optic connector interface, a single position plug connector set of plug/adapter configuration

More information

LF3800 stainless steel push-to-connect fittings

LF3800 stainless steel push-to-connect fittings 3800 push-to-connect fittings principle of system 3800 push-to-connect fitting system The 3800 range provides the advantages of push-to-connect fittings instant connection and disconnection for a wider

More information

ERF910. RF Repeater. Synco living

ERF910. RF Repeater. Synco living 2 704 Synco living RF Repeater ERF910 Wireless RF repeater for extending plant RF communication based on KNX standard (868 MHz, bidirectional) Mains-powered AC 2 V (with external power pack) Use For integration

More information

Interface Relay CRINT-1x

Interface Relay CRINT-1x Interface Relay CRINT-1x 1 Features Space saving interface relay to combine with PLCs Coil voltage UC12, 24, 48, 60, 110-125, 220-240V Integrated protection circuit Relay is replaceable separately Available

More information

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols /2.9 Gear Pump Model G2 (Series X For Flange Mounting with SE threaded Ports s to 22... 6 PSI (2 bar....7 in /rev. (22. cm /rev. /2.9 eplaces: 2.92 New principle of sealing the pump body, increases service

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

Networked Absolute Inclinometer Page 1 of 9

Networked Absolute Inclinometer Page 1 of 9 Page 1 of 9 Description The T7 is now IP68 rated. For more details, download the T7_IP_Certification. The T7 is a solid state absolute inclinometer that senses tilt angles over a full 360 range in a single

More information

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447 Procedure: BRAKE BUSHING REPLACEMENT PROCEDURE Product: Document #: Rev: Page: MODEL 7000, 7000A, & 8000 GYRO 078 1 1 of 14 Description: Detailed procedure on removing old bushing and installing new Brake

More information

Encoder WDG 63Q.

Encoder WDG 63Q. Encoder WDG Q www.wachendorffautomation.com/wdgq Wachendorff utomation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions

More information

Ball Spline Types LT and LF

Ball Spline Types LT and LF Ball Spline Types and LF Ball Spline nut Snap ring Seal Retainer Spline shaft Fig. Construction of Ball Spline Type Construction and Features Ball Spline types and LF have four or six trains of loadbearing

More information

11525A 11524A

11525A 11524A 8 Typical Configuration 11900A 11901A 11904A 8059A 1250-1159 1250-1748 85058-60007 11900C 11901C 11901D 11904C 11904D 8059C 1250-1462 85058-60009 1190A 1250-166 1250-174 11525A 11524A 11852B 11852B Option

More information

Blue Point Engineering

Blue Point Engineering DMX 8-Channel Driver Overview he DMX 8- Channel Driver board is designed to provide 8- consecutive channels of standard or extended range movements for analog type R/C s with output control pulses from

More information

SPH / MA and MA2 components MCS / MA multi-connections. Technical data sheet

SPH / MA and MA2 components MCS / MA multi-connections. Technical data sheet SPH / MA and MA2 components MCS / MA multi-connections Technical data sheet SPH / MA and MA2 components for MCS / MA automatic multi-connections Nominal bore 04, 06, 08, 12, 15, 20, 25, 37, 50 and 75 mm

More information

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65 Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated

More information

APPLICATION NOTE DD-100

APPLICATION NOTE DD-100 O Z OPTICS LTD. C A N A D A OZ OPTICS LTD. APPLICATION NOTE DD-100 OZ OPTICS FAMILY OF OEM MOTOR DRIVEN ATTENUATORS The information/data furnished in this document shall not be duplicated, used or disclosed

More information

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009 Catalogue electric-, cordless- and pneumatic power tools Products for sheet metal processing Edition 2008 / 2009 Machine Tools / Power Tools Laser Technology / Electronics Medical Technology Slitting shears

More information

Output Operating Switch Schmitt Trigger Combination Voltage & Locating Lug 291 V F 832 A B A Rev. D

Output Operating Switch Schmitt Trigger Combination Voltage & Locating Lug 291 V F 832 A B A Rev. D Precision, Long-life 12mm Optical Encoder Available with 4, 6, 8, 24,32, 64 Pulses per Revolution Optional Momentary Switch Multiple options for terminations, resolution, cable lengths, and operating voltage

More information

Interface Module IM-ME 40 for Counter ME40.xx

Interface Module IM-ME 40 for Counter ME40.xx Interface Module IM-ME 40 for Counter ME40.xx Brief description Revision 1.0 28.07.2015 Editor : K. Taulien 1 Introduction... 3 1.1 System... 3 1.2 Retraceability of cutting lengths... 4 1.3 Performance

More information

USB TO RS-232 OR RS-422/485 CONVERTER

USB TO RS-232 OR RS-422/485 CONVERTER DATA SHEET, USB TO RS-232 OR RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM RS-232 TD RD OVERVIEW USB TO RS-232 OR RS-422/485 OPTO-ISOLATED CONVERTER DATA SHEET INTRODUCTION

More information

Temperature sensors and accessories for heat and cooling measurement points

Temperature sensors and accessories for heat and cooling measurement points Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCH-POUND MIL-DTL-83723/68B 29 June 2009 SUPERSEDING MIL-C-83723/68A (USAF) 17 December 1991 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, (CIRCULAR, ENVIRONMENT RESISTING), PLUG, THREADED COUPLING,

More information

Premium Drillpipe. for Optimal Performance

Premium Drillpipe. for Optimal Performance Premium Drillpipe for Optimal Performance DRILCO offers a full line of premium drillpipe available in a variety of sizes with API and non-standard wall thickness to deliver optimal torque, weight, and

More information

Chapter. In this Chapter... Safety Guidelines Introduction Panel Cutout Dimensions (all models) Wiring Guidelines...

Chapter. In this Chapter... Safety Guidelines Introduction Panel Cutout Dimensions (all models) Wiring Guidelines... Installation & Wiring hapter In this hapter... Safety Guidelines... - Introduction... - Panel utout imensions (all models)... - Wiring Guidelines... - hapter : Installation and Wiring 0 Safety Guidelines

More information

3S 1 13,5 1/4 3013, /8 1/ ,2 3/8 3017, / ,3 1/2 4021,3

3S 1 13,5 1/4 3013, /8 1/ ,2 3/8 3017, / ,3 1/2 4021,3 DIN 3015, Part 2 Components: Dimensions / Order Codes Clamp Body ød1 S 1 Clamp Body One clamp body is consisting of two clamp halves. Colour: reen Material code: PP Colour: Black Material code: PA (87

More information

PTB111E_111E-500_111E-800

PTB111E_111E-500_111E-800 PTB111E_111E-500_111E-800 Manual Tablet Hardness Testing Instrument The manual tablet hardness testing instrument PTB111E / 111E-500 / 111E-800 is a dual force mode hardness test apparatus as it can be

More information

Motor Controllers. On-Road AC Motor Controller. Model 1239E.

Motor Controllers. On-Road AC Motor Controller. Model 1239E. Motor Controllers Model 29E www.curtisinstruments.com The E difference A significant enhancement to the Curtis AC family, The E models utilize a powerful dual-microprocessor logic architecture to provide

More information

Amphenol. 608 Series. Amphenol Limited. Design Features. Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608)

Amphenol. 608 Series. Amphenol Limited. Design Features. Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608) Amphenol 608 Series Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608) CE30 Design Features Keyway Polarisation. Ni Aluminium Bronze Shells. Threaded Anti Vibration coupling mechanism.

More information

Sockets & Accessories

Sockets & Accessories Sockets & Accessories Sidchrome socket sets give you the choice of socket you need to get the job done. Our sets have been designed with flexibility, quality and portability in mind. You can easily carry

More information

OIL INDIA LIMITED (A Government of India Enterprise) P.O. Duliajan, Pin Dist-Dibrugarh, Assam CORRIGENDUM

OIL INDIA LIMITED (A Government of India Enterprise) P.O. Duliajan, Pin Dist-Dibrugarh, Assam CORRIGENDUM OIL INDIA LIMITED (A Government of India Enterprise) P.O. Duliajan, Pin 786602 Dist-Dibrugarh, Assam CORRIGENDUM Addendum No. 1 Dated 30.03.2016 to Tender No. SSG0666L16/01 This Addendum No. 1 dated 30.03.2016

More information

OptiMatic 2 Automatic Powder System (AS02)

OptiMatic 2 Automatic Powder System (AS02) E Operating Instructions and Spare Parts List Automatic Powder System (AS0) Translation of the original operating instructions Issued /0 Table of Contents. Fields of application.... Scope of delivery....

More information

Ultrasonic Load Monitoring

Ultrasonic Load Monitoring Ultrasonic Load Monitoring Because ensuring a leak-free solution is critical. It has to be Hydratight. For more than 100 years, Hydratight has provided world-class bolted joint solutions, assessing and

More information

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Sensing distance 1.0 mm 1.5 mm 2.5 mm 5.0 mm High-precision Proximity Sensor Supply voltage 12 to 24 VDC Output 100 ma max., 2 outputs Ideal for Positioning and Discriminating Objects Assures minimal temperature

More information

RMI multi-couplings Control

RMI multi-couplings Control RMI multi-couplings Control Centralised connections for greater implementation speed Centralised connection of control circuits Optimised time for changing moulds Streamlined connections. Efficient and

More information

RH and Air Temperature Sensor

RH and Air Temperature Sensor Addendum to RHT3nl-CA Technical Manual RH and Air Temperature Sensor type RHT4nl-02 RHT4-UM-2 Delta-T Devices Ltd Notices Copyright All rights reserved. Under the copyright laws, this manual may not be

More information

Personal Back, Personal Back Plus, Matrx Personal Back10 Reg./Tall, Matrx Personal Back10 Plus Reg./Tall - For Round Canes

Personal Back, Personal Back Plus, Matrx Personal Back10 Reg./Tall, Matrx Personal Back10 Plus Reg./Tall - For Round Canes Item Number Note Part Number Description 1 2 B 3 B 4 5 6 7 E 8 F 9 F 10 11 12 13 J,K 13 J,K 13 I 13 I 14 15 16 17 C 17 D 18 18 19 20 A,G A,H A,L A Quantity Per Package Assembly MB-50 Kit, Top Mounting

More information

Making a Safer World Through Accuracy and Precision. Product Bulletin

Making a Safer World Through Accuracy and Precision. Product Bulletin Making a Safer World Through Accuracy and Precision Product Bulletin Follow us on Twitter @mountztorque PB # 0055 (Rev2) September 2015 www.mountztorque.com SD-Series Torque Control System The SD-Series

More information

SMK Connectors. General Description. Contents (Click on any line to go to the indicated page) Test Data

SMK Connectors. General Description. Contents (Click on any line to go to the indicated page) Test Data SMK Connectors General Description These high-performance SMK (2.92 mm) connectors feature maximum VSWR for cable connectors of 1.15:1 from DC to 18 GHz, and 1.3:1 from 18 to 40 GHz. The maximum VSWR for

More information

Enermet RO. Ripple Control Receiver. Product Description. Load Management Ripple Control Systems

Enermet RO. Ripple Control Receiver. Product Description. Load Management Ripple Control Systems Load Management Ripple Control Systems Ripple Control Receiver Enermet RO Product Description Document version: a 26.08.2009 File: RO Product Description D000031226_a.doc 2009 Landis+Gyr AG D 0 00 0 30

More information

AS-568B Standard O-Rings Quick Reference Chart

AS-568B Standard O-Rings Quick Reference Chart AS-568B Standard O-Rings Quick Reference Chart General Applications Apple O-Rings are available in a choice of seven basic materials (1) each in a range of optional Durometer (Shore A) Hardnesses. Other

More information

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

Optical Encoders. Sold & Serviced By:   Toll Free Phone: Toll Free Fax: SERVO-TEK SERVO-TEK PRODUCTS COMPANY, INC. Optical Encoders www.servotek.com Toll Free Phone: 877-378-0240 sales@servo2go.com RC-800 Summary Hollow Shaft Encoders ST50 Series High Performance Rotary Incremental

More information

CHECK STRESS ON DECK BASED ON SDI REQUIREMENTS

CHECK STRESS ON DECK BASED ON SDI REQUIREMENTS ANALYSIS OF NON-COMPOSITE CONCRETE SLAB ON METAL DECK Lab #7 Question #2 A 6" total depth lightweight concrete slab with compressive strength of 3000psi is placed simply supported on a galvanized steel

More information

security fasteners for every application

security fasteners for every application security fasteners for every application Welcome to Hafren 2 Specifying & Ordering Hafren Security Fasteners 5 2-Hole Screws 6 Pin Hex Screws 8 6-Lobe Pin Screws 10 6-Lobe Pin Self Drilling Screws 12 6-Lobe

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

4000 series Industrial resistive joysticks

4000 series Industrial resistive joysticks CABLE TECHNICAL Distinctive features and specifications Two standard mounting options Low current drain Variety of potentiometer options Robust All metal mechanism IP65 above panel Inherently immune to

More information

OptoPulse EIL580. The benchmark for incremental encoders.

OptoPulse EIL580. The benchmark for incremental encoders. OptoPulse EIL580 The benchmark for incremental encoders. OptoPulse EIL580 the established standard. OptoPulse EIL580 sets a benchmark in incremental encoders with 58 mm diameter. Cutting edge sensing technology

More information

TorqueStar Opta is the equipment of choice for the measurement and collection of torque data in the manufacturing environment.

TorqueStar Opta is the equipment of choice for the measurement and collection of torque data in the manufacturing environment. Key Features Torque or force indicator and data collector Simple readout to comprehensive audit tool Display of torque curves and specialist measurement routines Torque, angle and impulse count Track,

More information

SCHEDULE 40 FLUSH JOINT FITTINGS

SCHEDULE 40 FLUSH JOINT FITTINGS 130 PIPE SIZE 2.5' 5' 10' 20' 2.5' 5' 10' 20' 1" 11.19 15.29 22.87 41.16 17.51 25.41 39.31 72.77 1-1/4" 12.83 19.80 28.54 51.21 19.15 29.92 44.98 82.82 1-1/2" 16.78 25.79 43.10 74.53 23.10 35.91 59.53

More information

SPECIFICATION. Bulk Acoustic Wave Filter W. DATE September 5, 2014 WISOL. Byun, Kyung-Su. User WISOL CO., LTD.

SPECIFICATION. Bulk Acoustic Wave Filter W. DATE September 5, 2014 WISOL. Byun, Kyung-Su. User WISOL CO., LTD. SPECIFICATION Bulk Acoustic Wave Filter USER USER PART No. WISOL PART No. DOC. No. DATE September 5, 2014 REVISION WISOL Hong, Byung-Chul Byun, Kyung-Su Mun, Gil-Seop ISSUED BY APPROVED BY (R&D) APPROVED

More information

Ringlock is a range of robust circular

Ringlock is a range of robust circular Connectors is a range of robust circular connectors for industrial applications. It uses a metal bayonet coupling system for quick and reliable connections and thermoplastic bodies for low installed cost.

More information

TorqueStar Opta is the equipment of choice for the measurement and collection of torque data in the manufacturing environment.

TorqueStar Opta is the equipment of choice for the measurement and collection of torque data in the manufacturing environment. Key Features Torque or force indicator and data collector Simple readout to comprehensive audit tool Display of torque curves and specialist measurement routines Torque, angle and impulse count Track,

More information

Networked Absolute Inclinometer Page 1 of 9

Networked Absolute Inclinometer Page 1 of 9 Page 1 of 9 Description The T7 is now IP68 rated. For more details, download the T7_IP_Certification. The T7 is a solid state absolute inclinometer that senses tilt angles over a full 360 range in a single

More information

Setting a Global Standard. Specialty Connectors

Setting a Global Standard.  Specialty Connectors Setting a Global Standard www.drilquip.com Specialty Connectors DRILQUIP: A LEADER IN TECHNOLOGY AND QUALITY Recognized worldwide for cuttingedge exploration, drilling and production technology, DrilQuip

More information

Product Information. Universal gripper EZN

Product Information. Universal gripper EZN Product Information EZN EZN Robust. Flexible. Strong. EZN universal gripper Servo-electric 3-finger centric gripper with high gripping force and high maximum moment due to multi-tooth guidance Field of

More information

5KW Parallel Installation Guide

5KW Parallel Installation Guide 5KW Parallel Installation uide 1. Introduction This inverter can be used in parallel with maximum 6 units. The supported maximum output power is 60KW/60KVA. 2. Parallel cable You will find the following

More information

3.5mm VNA Calibration Kits

3.5mm VNA Calibration Kits 3.5mm VNA Calibration Kits DATA SHEET / 2Z-059 Models: 8050CK10 Fixed Load Kit 8050CK11 Fixed Load Kit Plus Adapters 8050CK20 Sliding Load Kit - Basic 8050CK21 Sliding Load Kit Plus Adapters 8050CK30 TRL

More information

2.92mm VNA Calibration Kits

2.92mm VNA Calibration Kits 2.92mm VNA Calibration Kits DATA SHEET / 2Z-058B Models: 8770CK10 Fixed Load Kit 8770CK11 Fixed Load Kit Plus Adapters 8770CK20 Sliding Load Kit 8770CK21 Sliding Load Kit Plus Adapters 8770CK30 TRL Kit

More information

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

Automation System TROVIS 5400 District Heating Controller TROVIS 5476 Automation System TROVIS 5400 District Heating Controller TROVIS 5476 On-off or three-step controller designed for wall or panel mounting (dimensions of front frame: 44 mm x 96 mm) Application Self-optimizing,

More information

ISO 1173 INTERNATIONAL STANDARD

ISO 1173 INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 1173 Third edition 2001-04-01 Assembly tools for screws and nuts Drive ends for hand- and machine-operated screwdriver bits and connecting parts Dimensions, torque testing Outils

More information

RMI multi-couplings. Temperature control

RMI multi-couplings. Temperature control RMI multi-couplings Temperature control Centralised s... Registered Community Design... for greater implementation speed A full range The multi-coupling range is composed of four main families corresponding

More information

Energy Management Energy Transducer Type ET112

Energy Management Energy Transducer Type ET112 Energy Management Energy Transducer Type Single phase energy transducer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

Earthbound Welded Anchor Calculations

Earthbound Welded Anchor Calculations Earthbound Welded Anchor Calculations Objective: Find a welded anchor to steel beam connection able to handle 1.125 inch diameter A193B7 Threaded. Calculate the welding requirements for welding a round

More information

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional

More information

Butterfly Control Valve. DMK/6 Series

Butterfly Control Valve. DMK/6 Series Butterfly Control Valve DMK/6 Series UL Listed for US and Canada UL 842 and ULc C125 & C842 File # MH 18741 Models DMK 707/6 (3/4 NPT) DMK 710/6 (1 NPT) DMK 712/6 (1 1/4 NPT) DMK 715/6 (1 1/2 NPT) DMK

More information

INSTALLATION AND COMMISSIONING CHECKLIST

INSTALLATION AND COMMISSIONING CHECKLIST Installation environment Ensure installation site meets environmental and physical constraints. [ ] Good [ ] Poor 2 Unpacking Check inverter condition after unpacking. [ ] Good [ ] Poor 3 Mounting bracket

More information

Inductive Cylinder Position Sensors

Inductive Cylinder Position Sensors Inductive Cylinder Position Sensors 4-Wire DC (NPN and PNP) 2-Wire AC/DC Weld immune 250, 000, and 3000 psi designs C-Series F-Series Rating (psi) Probe Diameter Inductive Cylinder Position Sensors Pepperl+Fuchs

More information

Z-15GW2277 Z-15GW2277-B

Z-15GW2277 Z-15GW2277-B Basic Switch GENERAL PURPOSE General Purpose Basic Switch High precision basic switch in a variety of styles Wide margins of operating conditions increase the operating speed range Available in general

More information

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and

More information

with extraction and return pipe

with extraction and return pipe Float switch with extraction and return pipe 351 TEG + Intake and extraction pipes and reliable measurement + Long lifetime due to contact-free reed technology + No calibration necessary + Switching points

More information

Encoder WDGI 63Q.

Encoder WDGI 63Q. ncoder WDGI Q www.wachendorffautomation.com/wdgiq Wachendorff utomation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions

More information

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m Through-Beam Sensor with Visible Red LED Visible Beam Allows Visual Confirmation of the Detection Spot, for Easy Installation and Maintenance Built-in amplifier Mutual interference protection filter included

More information

SPH/BA Motorsports. Clean-break couplings for high pressure circuits

SPH/BA Motorsports. Clean-break couplings for high pressure circuits SPH/BA Motorsports Clean-break couplings for high pressure circuits Choose SPH/BA couplings... Applications - shock absorbers, brake and hydraulic lines - lubrication and coolants Combine lightweight and

More information

EC axial fan - HyBlade

EC axial fan - HyBlade WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General

More information

Product Specifications

Product Specifications Product Specifications Customer : Model No. : Features : 5" PCAP True Flat Touch Monitor 7H Hardness Tempered Cover Glass 0 points Multi-touch 5" 4:3,024x768 (XGA) Resolution IPS Technology, Wide Viewing

More information

Downloaded from DEPARTMENT OF DEFENSE INTERFACE STANDARD RADIO FREQUENCY CONNECTOR INTERFACES FOR

Downloaded from   DEPARTMENT OF DEFENSE INTERFACE STANDARD RADIO FREQUENCY CONNECTOR INTERFACES FOR NOTICE OF CHANGE DEPARTMENT OF DEFENSE INTERFACE STANDARD RADIO FREQUENCY CONNECTOR INTERFACES FOR MIL-C-3643, MIL-C-3650, MIL-C-3655, MIL-C-25516, MIL-C-26637, MIL-PRF-39012, MIL-PRF-49142, MIL-PRF-55339,

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

Proportional relief valves type RZMO-A*

Proportional relief valves type RZMO-A* www.atos.com Table F007-9/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 871 Mass Flow Meter (MFM for Gases Type 871 can be combined with Direct flow measurement for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 in MEMS technology High accuracy Short response time

More information

#4-40 UNC-2A Pi & C Filters

#4-40 UNC-2A Pi & C Filters The products listed in this catalog are only a few of the thousands of variations that produces. For custom component design, please contact the factory direct. atalog 000R Revised /0/0 #-0 UN-A & Filters

More information

Water Supply and Sewerage Approved Products Manual - February 2006

Water Supply and Sewerage Approved Products Manual - February 2006 Water Supply and Sewerage Approved Products Manual - February 2006 Water Supply Maintenance Products Section WO 04 Last updated January 2007 CONTENTS SPECIFICATIONS A WO 04-S1A MULTI-PURPOSE UNRESTRAINED

More information

Section 20 Distribution (Underground)

Section 20 Distribution (Underground) PREVIOUS SEARCH NEXT Section Distribution (Underground) Table of Contents Page Underground Connectors...-2 Padmount Transformer Connectors...-3 Pedestal Connectors...-4 Pedestal Block Connector...-6 Street

More information

MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Mode

MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Mode MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Models Available Integrated Overvoltage Protection by Automatic

More information

TEX. Spare parts list. Handheld pneumatic pick hammers 03PS Atlas Copco Construction Tools AB No

TEX. Spare parts list. Handheld pneumatic pick hammers 03PS Atlas Copco Construction Tools AB No TEX 0PS Spare parts list Handheld pneumatic pick hammers 0 Atlas Copco Construction Tools AB No. 9800 0976 0 004 TEX 0PS Contents Contents General information................................................................

More information

General Specifications

General Specifications Series ND mm Process Sealed SMT DIP otaries eneral Specifications Electrical apacity (esistive Load) Switching ating: ma @ 5V D Nonswitching ating: ma @ 5V D Other atings ontact esistance: Insulation esistance:

More information

I/O delay. (0.32 in ±0.06 in)

I/O delay. (0.32 in ±0.06 in) R Inductive Power Couplers Allows Wireless Transmission of ON/OFF Signals from Input Devices and Power to Input Devices H Use the electromagnetic coupler to transmit input signals to the B7A Output Unit

More information

ABSOLUTE ROTARY ENCODER INTERBUS

ABSOLUTE ROTARY ENCODER INTERBUS Main Features - Compact and heavy duty industrial model - Interface: Remote-Bus - ENCOM-Profile: K (programmable) - Housing: 58 mm - Shaft: 6 or 10 mm, hollow- 15 mm - Resolution: max. 25 Bit =,554,42

More information

RMI multi-couplings Temperature control

RMI multi-couplings Temperature control RMI multi-couplings Temperature control Centralised s... New models Even more efficient. Applications ew features to discover on pages N 6 and 7. Even better performance ptimum mechanical strength and

More information

V0. PLAY Downlight recessed. Description Recessed for indoor use.

V0. PLAY Downlight recessed. Description Recessed for indoor use. 71-3225-14-37 V0 Downlight recessed Description Recessed for indoor use. For downlighting. Very versatile with multiple types of installation possible. Up to 40,000 possible combinations. Lenses allow

More information

Technical Data Sheet Screw Clamps and Universal Clamps

Technical Data Sheet Screw Clamps and Universal Clamps Technical Data Sheet Screw Clamps and Universal Clamps Stepless Screw Clamps PG 178 2 PG 178 for small diameters PG 178 for big diameters Bridge Tongue-in-groove design Interlock with multiple diameter

More information

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7

More information

Description. SmartControl with PoE: SSC-P008. Feature Summary. Rear View of SSC-P008

Description. SmartControl with PoE: SSC-P008. Feature Summary. Rear View of SSC-P008 The SmartControl 8 with Power over Ethernet (SSC-P008) is part of the Savant SmartControl family designed to provide infrared (IR) and serial control of third party devices. The SSC-P008 supports Power

More information