Putting the pieces together: HMC, FSP, firmware, ASMI, and OS.

Size: px
Start display at page:

Download "Putting the pieces together: HMC, FSP, firmware, ASMI, and OS."

Transcription

1 Putting the pieces together: HMC, FSP, firmware, ASMI, and OS. Pete Massiello itech Solutions itech Solutions because IBM i (AS/400 s) didn t come with System Administrators. 0

2 In this session We will cover what you need to know about the Hardware Management Console, the Flexible Service Processor, and IBM i. What they are, how we connect them together, the relationships amongst one another, and how we perform upgrades to each. In addition, you will learn basic maneuverability around the HMC as we discuss all these tasks. 1

3 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 2

4 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 3

5 Overview of i5/os, FSP, and HMC i5/os Linux i5/os LIC A B LIC A B Power Hypervisor PHYP Flexible Service Processor (FSP) HMC 1 Flash Memory HMC 2 Perm Temp System Power Cont. Network (SPCN) 4

6 Hardware Management Console (HMC) Intel based PC appliance running LINUX for managing of partitions on Power5, Power6, Power7, and Power8 hardware Functions: Management of Partitions HMC Licensed Internal Code Maintenance HMC Users and Configuration Service Applications Local Info Center 5

7 HMC Easy to Manage Can Be Used as Console Remote Console Access Remote Access of HMC Partitions Can Run Without Connection to HMC Provides Direct Link to ASMI (Advanced Systems Management Interface) 6

8 HMC HMC xxxx-crx Rack mounted 7042-CR9 Latest Rack Mounted xxxx-c0x Desk Top (end of Life) Mirrored disks now available Note: Versions earlier than 7310-C04 will not load HMC 7.7 and later. Power8 needs or higher Can t load on a CR4 or lower Last to support classic view 7

9 HMC HMC 8

10 Flexible Service Processor (FSP) The service processor runs on its own power boundary and continually monitors hardware attributes and the environmental conditions within the server. The FSP is responsible for loading the PHYP code from Flash into system memory and starting the system processors. FSP does not deal directly with OS/400 SLIC nor IBM AIX /Linux Open Firmware/RTAS. FSP directly communicates only with the Real Control Panel, PHYP, or the HMC. The Flexible Service Processor (FSP) firmware provides diagnostics, initialization, configuration, run-time error detection, and correction. 9

11 Advanced Systems Management Interface (ASMI) Service Processors Menus Connect via https and your Browser through HMC 1 and HMC 2 ports on i5 using addresses: Power5: and Power6, 7, & 8: and Perform general and administrator-level service tasks such as reading service processor error logs, reading vital product data, setting up the service processor, and controlling the system power. 10

12 i5/os, FSP, and HMC i5/os Linux i5/os LIC A B LIC A B Power Hypervisor PHYP Flexible Service Processor (FSP) HMC 1 Flash Memory HMC 2 Perm Temp System Power Cont. Network (SPCN) 11

13 ASMI

14 ASMI Firmware Update Policy

15 Partitions - LIC and i5/os This has not changed. Still Licensed Internal Code , , IBM I (i5/os) is 5722-SS1, 5761-SS1, or 5770-SS1. Same for AIX. Loaded on EACH partition. Not shared between partitions. LIC is NOT Server firmware on the FSP. 14

16 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 15

17 Connectivity HMC Port 1 Eth0 Eth1 16

18 Connectivity (cont.) HMC ETH0 Configured as DHCP server Unique set of addresses Connects to closed network FSP Port HMC1 HMC ETH1 Connected to open network Remote connections come in through here Internet connection ordering PTFs, updates 17

19 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 18

20 Upgrade Order First: HMC Next: FSP Last: Local OS (LIC and i5/os) or AIX 19

21 HMC and FSP Combinations 20

22 Update HMC (From V6 and Earlier)

23 Update HMC Copyright 2007 itech Solutions

24 Update HMC Copyright 2007 itech Solutions

25 Updating the HMC Recovery Media Bootable DVD Version Upgrade Corrective Service CD Internet download/ftp site Like a PTF 24

26 New Release or Version Done as an IPL of the HMC using Bootable DVD Always do SAVE Upgrade Data Before. Always backup to External Media: CD or USB Flash-Drive To 8.8.6: getupgfiles -h public.dhe.ibm.com -u anonymous --passwd anonymous -d /software/server/hmc/network/v8860 chhmc -c altdiskboot -s enable --mode upgrade hmcshutdown -r -t now 25

27 Two Types of Backups HMC Data (Critical Console Data)

28 Always Save Upgrade Data before Upgrade Copyright 2007 itech Solutions

29 Corrective Service: HMC PTFs Copyright 2007 itech Solutions

30 Corrective Service: Remote HMC PTFs updhmc -t ftp -h public.dhe.ibm.com -u anonymous --passwd ftp -r -f /software/server/hmc/fixes/mh99999.iso Copyright 2017 itech Solutions

31 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 30

32 Releases Server Firmware Server Firmware: PPNNSSS_FFF_DDD: PP = package identifier; 01 = managed system and 02 = power subsystem. NN = machine type model group; SF = system firmware P5, BP = bulk power, Ex = Power6 (x=l, M, or H), Ax = Power7 SSS = fixpack code stream indicator FFF = fixpack number for current fixpack level DDD = fixpack number for the last disruptive fixpack level Power5 : 01_SF240_338_201 Power6: EM310_057_048 Power7: AL730_043 Power8: SV840_056 31

33 FSP: PTFs vs. Version Change License Internal Code for the current release: Like putting on a PTF Upgrade License Internal Code to a new release: Like a new version. i.e., 01_SF235 to 01_SF240 32

34 Change FSP Code

35 Change FSP Code

36 Permanently Apply What Is Temp 35

37 Permanently Apply What Is Temp 36

38 FSP: Advanced Features 37

39 FSP: Perm Apply 38

40 Successful 39

41 Change Server Code (Within Release) 40

42 Select Source of Update 41

43 Run Through the Wizard 42

44 FSP: Update Licensed Internal Code 43

45 FSP: Get the Lawyers Involved 44

46 FSP: About to Update 45

47 FSP: What Levels Will Be 46

48 FSP: No HMC Firmware Service Update Policy MUST be set to OS Managed. Updates received from MH PTFs on (V5R4M0). If V5R4M5, V6R1, or V7R1 then x where x is 5 for Power5 or 6 for Power6, 7 is for Power7, and 8 for Power8. To display the level: Run the STRSST command. Select Option 1, Start a service tool. Select Option 4, Display/Alter/Dump. Select Option 1, Display/Alter storage. Select Option 2, Licensed Internal Code (LIC) data. Select Option 14, Advanced analysis. Select FLASHLEVELS, Press the Enter key. 47

49 DSPFMWSTS

50 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 49

51 System Plans System Planning Tool. New. LPAR Validation Tool (LVT). Now old. Define the configuration of the Power Systems Where the I/O Adapters (cards) go Which resources are on which partitions? Divides Memory and CPW (Batch and Interactive) Run from your PC 50

52 Download SPT 51

53 SPT: Card Placement 52

54 SPT: Card Placement (cont.) 53

55 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 54

56 HMC 7 Welcome Screen 55

57 HMC 8 Signon Screen 56

58 HMC 8 Starting screen 57

59 HMC 8 Starting screen 58

60 Partitions and Profiles

61 Partitions and Profiles

62 Activate: Starting a Partition

63 Activate: Starting a Partition

64 Activation Changes take affect at Activation not at PWRDWNSYS Restart(*YES) Looks for Min Resources to activate 63

65 Activation Partition Advanced Opt 64

66 Partition Starting

67 Replaces Front Bezel for Partitions

68 Partition Information

69 History of SRC Codes 68

70 Partition Shutting Down

71 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 70

72 HMC Users and Configuration

73 HMC Users

74 HMC Users 73

75 HMC: Add a User 74

76 HMC Configuration

77 HMC Configuration

78 HMC: Network Settings 77

79 HMC: Network Adapters 78

80 HMC: ETH0: Private Network 79

81 HMC: ETH1: Open Network 80

82 HMC: ETH1: Internal Firewall 81

83 HMC: DNS and Routing 82

84 HMC: Schedule Tasks 83

85 HMC: Schedule Tasks 84

86 Backup Critical Console Data 85

87 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 86

88 HMC: Service Agent

89 HMC: Service Agent

90 HMC: Send Service Notifications 89

91 Attention LEDs

92 Manage Attention LEDs Copyright 2007 itech Solutions 91 91

93 HMC: Turn Alert Light Off 92

94 Operator Panel Service Functions Copyright 2007 itech Solutions 93

95 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 94

96 HMC and System Plans 95

97 HMC: Import System Plan 96

98 Manage System Plans Copyright 2007 itech Solutions 97

99 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 98

100 No more WebSM Use HTTPS 99

101 What We ll Cover What Is Each Component? How Are They Connected? How Do We Upgrade? HMC Code Update FSP Server Code Update System Plans (Old LVT) Partitions and Profiles HMC Users and Configuration Service Agent Using System Plans Using Remote Connections (Was WebSM) Wrap-up 100

102 7 Key Points to Take Home Configure HMC before powering on i5 ETH0 on HMC configured as a private network with DHCP. Remote Access to your HMC via Update of software order is important HMC, FSP, LIC, and i5/os Use System Planning Tool to design your machine Remember a Disruptive update to the FSP will immediately end all partitions if they are still active Backup your HMC to EXTERNAL media before an upgrade 101

103 Your Turn! How to contact me: Pete Massiello Twitter: PeteM59 102

HMC and System Firmware

HMC and System Firmware HMC and System Firmware Janus Hertz Senior IT Specialist Nordic Technical Leader for System i AIX/Linux/Windows/VMware Integration i want stress-free IT. i want control. Hardware Management Console (HMC)

More information

What you need to know to do successful IBM i upgrades to 7.1, 7.2, 7.3

What you need to know to do successful IBM i upgrades to 7.1, 7.2, 7.3 What you need to know to do successful IBM i upgrades to 7.1, 7.2, 7.3 Pete Massiello itech Solutions pmassiello@itechsol.com 203-744-7854 itech Solutions because IBM i (AS/400s) don t come with System

More information

HMC The New Console on the Block John Still

HMC The New Console on the Block John Still HMC The New Console on the Block John Still Objectives Console History Introducing the Hardware Management Console (HMC) Planning for HMC and i5 Guided Setup Wizard HMC Management Remote Access System

More information

Power Systems Firmware Management - What You Need to Know

Power Systems Firmware Management - What You Need to Know Power Systems Firmware Management - What You Need to Know Tracy Smith Executive IT Specialist (ATS) IBM Power Systems - Rochester, MN Tues. June 2, 2015 Technical University/Symposia materials may not

More information

Cool things in Navigator for IBM i to be a Rock Star Administrator

Cool things in Navigator for IBM i to be a Rock Star Administrator Cool things in Navigator for IBM i to be a Rock Star Administrator itech Solutions because IBM i (AS/400s) don t come with System Administrators Pete Massiello itech Solutions pmassiello@itechsol.com 203-744-7854

More information

System i and System p. Creating a virtual computing environment

System i and System p. Creating a virtual computing environment System i and System p Creating a virtual computing environment System i and System p Creating a virtual computing environment Note Before using this information and the product it supports, read the information

More information

IBM Power Systems tm. System Firmware (Microcode) Service Strategies and Best Practices

IBM Power Systems tm. System Firmware (Microcode) Service Strategies and Best Practices IBM Power Systems tm System Firmware (Microcode) Service Strategies and Best Practices IBM Power Systems tm System Firmware (Microcode) Service Strategies and Best Practices IBM Corporation For comments

More information

IBM i5 iseries Technical Solutions Designer V5R3. Download Full Version :

IBM i5 iseries Technical Solutions Designer V5R3. Download Full Version : IBM 000-866 i5 iseries Technical Solutions Designer V5R3 Download Full Version : http://killexams.com/pass4sure/exam-detail/000-866 Answer: A QUESTION: 116 A customer's production and test environments

More information

ERserver. Service provider information Service functions

ERserver. Service provider information Service functions ERserver Service provider information Service functions ERserver Service provider information Service functions Note Before using this information and the product it supports, be sure to read the information

More information

February 2011 itech Solutions because IBM i (AS/400, iseries) didn't come with a System Administrator.

February 2011 itech Solutions because IBM i (AS/400, iseries) didn't come with a System Administrator. News from itech Solutions - i5/os & IBM i 1 of 13 February 2011 itech Solutions because IBM i (AS/400, iseries) didn't come with a System Administrator. In This Issue Your Backups are worthless... Managing

More information

Larry Bolhuis, Arbor Solutions, Inc.

Larry Bolhuis, Arbor Solutions, Inc. Session: HMC, Operations Console and Twinax: You Choose! 2006 Michigan iseries Technical Conference Larry Bolhuis, Arbor Solutions, Inc. Grand Rapids 1345 Monroe NW Suite 259 Grand Rapids, MI 49505 616-451-2500

More information

SF Current Cumulative PTF Package. I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N

SF Current Cumulative PTF Package. I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N SF98720 Current Cumulative PTF Package I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N Copyright IBM Corporation 1993, 2017 - The information in this document was last updated:

More information

Security Service tools user IDs and passwords

Security Service tools user IDs and passwords IBM Systems - iseries Security Service tools user IDs and passwords Version 5 Release 4 IBM Systems - iseries Security Service tools user IDs and passwords Version 5 Release 4 Note Before using this information

More information

SF Current Cumulative PTF Package. I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N

SF Current Cumulative PTF Package. I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N SF98730 Current Cumulative PTF Package I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N Copyright IBM Corporation 1993, 2018 - The information in this document was last updated:

More information

i5/os and related software Installing, upgrading, or deleting i5/os and related software

i5/os and related software Installing, upgrading, or deleting i5/os and related software i5/os i5/os and related software Installing, upgrading, or deleting i5/os and related software Version 6 Release 1 SC41-5120-10 i5/os i5/os and related software Installing, upgrading, or deleting i5/os

More information

System i and System p. Service provider information Reference information

System i and System p. Service provider information Reference information System i and System p Service provider information Reference information System i and System p Service provider information Reference information Note Before using this information and the product it

More information

IBM System I Technical Solutions Design (including i5/os V5R4) Download Full Version :

IBM System I Technical Solutions Design (including i5/os V5R4) Download Full Version : IBM 000-868 System I Technical Solutions Design (including i5/os V5R4) Download Full Version : https://killexams.com/pass4sure/exam-detail/000-868 QUESTION: 136 At i5/os V5R4, what is the minimum Microsoft

More information

SF Current Cumulative PTF Package. I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N

SF Current Cumulative PTF Package. I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N SF98710 Current Cumulative PTF Package I B M i P R E V E N T I V E S E R V I C E P L A N N I N G I N F O R M A T I O N Copyright IBM Corporation 1993, 2017 - The information in this document was last updated:

More information

HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements

HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements August 2017 Table of Contents Contributing Author: Karyn Corneli Co-Author: Jacobo Vargas Introduction...

More information

Power Systems. Overview of SDMC

Power Systems. Overview of SDMC Power Systems Overview of SDMC Power Systems Overview of SDMC te Before using this information and the product it supports, read the information in tices on page 33. This edition applies to IBM Systems

More information

Frequently Asked Questions for V5R2M0 Electronic Service Agent for iseries

Frequently Asked Questions for V5R2M0 Electronic Service Agent for iseries Frequently Asked Questions for V5R2M0 Electronic Service Agent for iseries Q1: Where can I get media for the Electronic Service Agent product (5798-RZG)? A1: New systems leaving IBM from manufacturing

More information

System i and System p. Managing the Integrated Virtualization Manager

System i and System p. Managing the Integrated Virtualization Manager System i and System p Managing the Integrated Virtualization Manager System i and System p Managing the Integrated Virtualization Manager Note Before using this information and the product it supports,

More information

CA Agile Central Installation Guide On-Premises release

CA Agile Central Installation Guide On-Premises release CA Agile Central Installation Guide On-Premises release 2016.2 Agile Central to Go 2017.1 rallysupport@rallydev.com www.rallydev.com 2017 CA Technologies (c) 2017 CA Technologies Version 2016.2 (c) Table

More information

.FO OFF. IBM i PTF Shipping Information Letter

.FO OFF. IBM i PTF Shipping Information Letter SF99610 C5063610 Cumulative PTF Package Instructions This PSP consists of: Short Version of Installation Instructions, and Detailed Installation Instructions..FO OFF IBM i PTF Shipping Information Letter

More information

Tips and Tricks to improve system performance and save disk space. Pete Massiello itech Solutions

Tips and Tricks to improve system performance and save disk space. Pete Massiello itech Solutions Tips and Tricks to improve system performance and save disk space. Pete Massiello itech Solutions pmassiello@itechsol.com 203-744-7854 0 In this session In this presentation we will discuss the ways to

More information

The Balabit s Privileged Session Management 5 F5 Azure Reference Guide

The Balabit s Privileged Session Management 5 F5 Azure Reference Guide The Balabit s Privileged Session Management 5 F5 Azure Reference Guide March 12, 2018 Abstract Administrator Guide for Balabit s Privileged Session Management (PSM) Copyright 1996-2018 Balabit, a One Identity

More information

iseries Tech Talk Linux on iseries Technical Update 2004

iseries Tech Talk Linux on iseries Technical Update 2004 iseries Tech Talk Linux on iseries Technical Update 2004 Erwin Earley IBM Rochester Linux Center of Competency rchlinux@us.ibm.com Agenda Enhancements to the Linux experience introduced with i5 New i5/os

More information

CA Agile Central Administrator Guide. CA Agile Central On-Premises

CA Agile Central Administrator Guide. CA Agile Central On-Premises CA Agile Central Administrator Guide CA Agile Central On-Premises 2018.1 Table of Contents Overview... 3 Server Requirements...3 Browser Requirements...3 Access Help and WSAPI...4 Time Zone...5 Architectural

More information

POWER Block Course Assignment 2: System Management. Hasso-Plattner Institute

POWER Block Course Assignment 2: System Management. Hasso-Plattner Institute POWER Block Course Assignment 2: System Management Hasso-Plattner Institute Agenda 1. General Information 2. Assignment 2 System Management 3. Helpful Links / Troubleshooting Assignment 2 System management

More information

System p. Partitioning with the Integrated Virtualization Manager

System p. Partitioning with the Integrated Virtualization Manager System p Partitioning with the Integrated Virtualization Manager System p Partitioning with the Integrated Virtualization Manager Note Before using this information and the product it supports, read the

More information

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004 pseries Partitioning AIX 0 Jaqui Lynch USERblue 2004 Jaqui.lynch@mainline.com http://www.circle4.com/papers/ubaixpart04.pdf Agenda Partitioning Concepts Hardware Software Planning Hints and Tips References

More information

IBM Systems Director Service and Support Manager

IBM Systems Director Service and Support Manager IBM Systems IBM Systems Director Service and Support Manager Version 6.3 IBM Systems IBM Systems Director Service and Support Manager Version 6.3 Note Before using this information and the product it

More information

IBM Virtualization Technical Support for AIX and Linux - v2.

IBM Virtualization Technical Support for AIX and Linux - v2. IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 http://killexams.com/exam-detail/000-109 QUESTION: 170 A Power Systems server has two HMCs connected to its Flexible Service Processor

More information

Integrated Virtualization Manager. ESCALA Power7 REFERENCE 86 A1 41FF 08

Integrated Virtualization Manager. ESCALA Power7 REFERENCE 86 A1 41FF 08 Integrated Virtualization Manager ESCALA Power7 REFERENCE 86 A1 41FF 08 ESCALA Models Reference The ESCALA Power7 publications concern the following models: Bull Escala E1-700 / E3-700 Bull Escala E1-705

More information

IBM i PTF Shipping Information Letter

IBM i PTF Shipping Information Letter SF99730 C8025730 Cumulative PTF Package Instructions This PSP consists of: Short Version of Installation Instructions, and Detailed Installation Instructions. IBM i PTF Shipping Information Letter IBM

More information

iresetme Version 2.01 As of August 2014 Kisco Information Systems 89 Church Street Saranac Lake, New York 12983

iresetme Version 2.01 As of August 2014 Kisco Information Systems 89 Church Street Saranac Lake, New York 12983 iresetme Version 2.01 As of August 2014 Kisco Information Systems 89 Church Street Saranac Lake, New York 12983 Phone: (518) 897-5002 FAX: (518) 897-5003 E-mail: Sales@Kisco.com WWW: http://www.kisco.com

More information

Tips and Tricks to improve system performance and save disk space.

Tips and Tricks to improve system performance and save disk space. Tips and Tricks to improve system performance and save disk space. Pete Massiello itech Solutions pmassiello@ 203-744-7854 itech Solutions because IBM i (AS/400s) don t come with System Administrators

More information

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX KillTest Q&A Exam : 000-108 Title : Enterprise Technical Support for AIX and Linux -v2 Version : Demo 1 / 7 1.Which power reduction technology requires a software component in order to be activated? A.

More information

Users guide for IBM Entitled Systems Support website.

Users guide for IBM Entitled Systems Support website. Users guide for IBM Entitled Systems Support website. www.ibm.com/eserver/ess Last update: June 2015 INDEX OF CONTENTS PART I : MY ENTITLED SOFTWARE Power i, iseries, AS/400 software keys (IBM i only)

More information

IBM Power Systems Sales for the IBM I Operating System. Download Full Version :

IBM Power Systems Sales for the IBM I Operating System. Download Full Version : IBM 000-973 Power Systems Sales for the IBM I Operating System Download Full Version : http://killexams.com/pass4sure/exam-detail/000-973 is running an 810 2-way a nd is experiencing performance problems.

More information

IBM. User's Guide and Installation and Service Guide. Supplement to the RS/6000 Enterprise Servers S70 and S7A:

IBM. User's Guide and Installation and Service Guide. Supplement to the RS/6000 Enterprise Servers S70 and S7A: Supplement to the RS/6000 Enterprise Servers S70 and S7A: IBM User's Guide and Installation and Service Guide User's Guide (SA38-0549-01), and Installation and Service Guide (SA38-0548-01) SN32-9068-00

More information

Experiences with VIOS support for IBM i

Experiences with VIOS support for IBM i Experiences with VIOS support for IBM i Pete Stephen, Power Systems / AIX Architect Sirius Computer Solutions Pete.Stephen@siriuscom.com Agenda VIO overview Virtualization Trends. PowerVM and how do I

More information

Intel Entry Storage System SS4000-E

Intel Entry Storage System SS4000-E Intel Entry Storage System SS4000-E Software Release Notes January 2007 Storage Systems Technical Marketing Engineering Document Revision History Intel Entry Storage System SS4000-E Document Revision History

More information

IBM i PTF Shipping Information Letter

IBM i PTF Shipping Information Letter SF99710 C7192710 Cumulative PTF Package Instructions This PSP consists of: Short Version of Installation Instructions, and Detailed Installation Instructions. IBM i PTF Shipping Information Letter IBM

More information

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HPE VMware ESXi and vsphere. Part Number: 818330-003 Published: April

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-106 EXAM QUESTIONS & ANSWERS Number: 000-106 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ IBM 000-106 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with

More information

PD-SATA USB/LAN Network Attached Storage Enclosure for 3.5 SATA Hard Drives

PD-SATA USB/LAN Network Attached Storage Enclosure for 3.5 SATA Hard Drives Network Attached Storage Enclosure for 3.5 SATA Hard Drives User Manual & Installation Guide March 16, 2008 - v1.0 Table of Contents 1 INTRODUCTION...1 1.1 ICON KEY...1 1.2 THE...1 1.3 PACKAGE CONTENTS...1

More information

Hardware installation and use Control panel

Hardware installation and use Control panel System i Hardware installation and use Control panel Version 5 Release 4 System i Hardware installation and use Control panel Version 5 Release 4 Note Before using this information and the product it

More information

How To Install Windows Update Vista Without Cd Dell Inspiron 1720

How To Install Windows Update Vista Without Cd Dell Inspiron 1720 How To Install Windows Update Vista Without Cd Dell Inspiron 1720 Dell note the date of their systems on their FTP Website: Press any key when prompted such as h when it says Press any Key to boot from

More information

IBM iseries Linux Solution Sales v5r3.

IBM iseries Linux Solution Sales v5r3. IBM 000-851 iseries Linux Solution Sales v5r3 http://killexams.com/exam-detail/000-851 QUESTION: 51 A customer with an installed i825 is interested in setting up SAMBA on Linux to consolidate several Windows-based

More information

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E Sidewinder Hardware Guide Models S1104, S2008, S3008 Revision E Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Models and features... 4 Supported software...

More information

IBM System i Model 515 offers new levels of price performance

IBM System i Model 515 offers new levels of price performance IBM Europe Announcement ZG07-0267, dated April 10, 2007 IBM System i Model 515 offers new levels of price performance Description...2 Product positioning... 7 At a glance System i model 515 Express Configurations

More information

CounterACT 7.0. Quick Installation Guide for a Single Virtual CounterACT Appliance

CounterACT 7.0. Quick Installation Guide for a Single Virtual CounterACT Appliance CounterACT 7.0 Quick Installation Guide for a Single Virtual CounterACT Appliance Table of Contents Welcome to CounterACT Version 7.0... 3 Overview... 4 1. Create a Deployment Plan... 5 Decide Where to

More information

NN Nortel Communication Server 1000 Linux Platform Base and Applications Installation and Commissioning

NN Nortel Communication Server 1000 Linux Platform Base and Applications Installation and Commissioning Linux Platform Base and Applications Installation and Commissioning Release: Release 5.5 Document Revision: 02.09 www.nortel.com NN43001-315. Release: Release 5.5 Publication: NN43001-315 Document release

More information

IBM i on a Power Blade Read-me First. Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN

IBM i on a Power Blade Read-me First. Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN IBM i on a Power Blade Read-me First Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN vess@us.ibm.com October 30 th, 2009 1 This read-me first document provides detailed instructions on

More information

Power Systems. IBM Power 595 (9119-FHA) removal and replacement procedures

Power Systems. IBM Power 595 (9119-FHA) removal and replacement procedures Power Systems IBM Power 595 (9119-FHA) removal and replacement procedures Power Systems IBM Power 595 (9119-FHA) removal and replacement procedures Note Before using this information and the product it

More information

IBM i Version 7.2. Systems management Logical partitions IBM

IBM i Version 7.2. Systems management Logical partitions IBM IBM i Version 7.2 Systems management Logical partitions IBM IBM i Version 7.2 Systems management Logical partitions IBM Note Before using this information and the product it supports, read the information

More information

iresetme Version 2.27 As of January 2017 Kisco Information Systems 89 Church Street Saranac Lake, New York 12983

iresetme Version 2.27 As of January 2017 Kisco Information Systems 89 Church Street Saranac Lake, New York 12983 iresetme Version 2.27 As of January 2017 Kisco Information Systems 89 Church Street Saranac Lake, New York 12983 Phone: (518) 897-5002 FAX: (518) 897-5003 E-mail: Sales@Kisco.com WWW: http://www.kisco.com

More information

Halcyon MQ Manager. v14.0 Installation Guide

Halcyon MQ Manager. v14.0 Installation Guide v14.0 Installation Guide Copyright Copyright HelpSystems, LLC. All rights reserved. www.helpsystems.com US: +1 952-933-0609 Outside the U.S.: +44 (0) 870 120 3148 IBM, AS/400, OS/400, System i, System

More information

ForeScout CounterACT. Single CounterACT Appliance. Quick Installation Guide. Version 8.0

ForeScout CounterACT. Single CounterACT Appliance. Quick Installation Guide. Version 8.0 ForeScout CounterACT Single CounterACT Appliance Version 8.0 Table of Contents Welcome to CounterACT Version 8.0... 4 CounterACT Package Contents... 4 Overview... 5 1. Create a Deployment Plan... 6 Decide

More information

IBM ^ iseries Logical Partition Isolation and Integrity

IBM ^ iseries Logical Partition Isolation and Integrity June 2002 IBM ^ iseries Logical Partition Isolation and Integrity Dave Boutcher IBM Corporation boutcher@us.ibm.com Version 1.0 Page 1 Introduction The purpose of this document is to provide information

More information

CITRIX 1Y0-200 EXAM QUESTIONS & ANSWERS

CITRIX 1Y0-200 EXAM QUESTIONS & ANSWERS CITRIX 1Y0-200 EXAM QUESTIONS & ANSWERS Number: 1Y0-200 Passing Score: 800 Time Limit: 120 min File Version: 38.7 http://www.gratisexam.com/ CITRIX 1Y0-200 EXAM QUESTIONS & ANSWERS Exam Name: Managing

More information

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi and vsphere. HP Part Number: 616896-409 Published: September

More information

LENS Server Maintenance Guide JZ 2017/07/28

LENS Server Maintenance Guide JZ 2017/07/28 LENS Server Maintenance Guide JZ 2017/07/28 Duty Maintain LENS server with minimum downtime Patch critical vulnerabilities Assist LAB member for using the LENS services Evaluate for custom requirements

More information

Deployment Guide: Routing Mode with No DMZ

Deployment Guide: Routing Mode with No DMZ Deployment Guide: Routing Mode with No DMZ March 15, 2007 Deployment and Task Overview Description Follow the tasks in this guide to deploy the appliance as a router-firewall device on your network with

More information

InstantData USER MANUAL. For Microsoft Windows

InstantData USER MANUAL. For Microsoft Windows InstantData USER MANUAL For Microsoft Windows Copyright Notice & Proprietary Information Redstor Limited, 2016. All rights reserved. Instruction Symbols The following icons appear in the document: Note:

More information

Exam Questions C

Exam Questions C Exam Questions C9010-250 Power Systems with POWER8 Sales Skills V1 1. A credit card company is going to implement a new application for which security is a major requirement. The company has been quoted

More information

Device Manager. Managing Devices CHAPTER

Device Manager. Managing Devices CHAPTER 2 CHAPTER This chapter describes how to perform routine device management tasks using the Administrator Console. It provides information on managing the devices within your Cisco VXC Manager environment.

More information

HySecure Quick Start Guide. HySecure 5.0

HySecure Quick Start Guide. HySecure 5.0 HySecure Quick Start Guide HySecure 5.0 Last Updated: 25 May 2017 2012-2017 Propalms Technologies Private Limited. All rights reserved. The information contained in this document represents the current

More information

Storage Made Easy Cloud Appliance installation Guide

Storage Made Easy Cloud Appliance installation Guide dev.storagemadeeasy.com Storage Made Easy Cloud Appliance installation Guide 4 min read original Configuring the SME Appliance The configuration server allows you to configure - Static IP address - Domain

More information

USB2.0 IDE & LANDISK External Enclosure

USB2.0 IDE & LANDISK External Enclosure USB2.0 IDE & LANDISK External Enclosure CONTENT User s Manual 1. Product Information.....................1 2. Product Specifications....................2 3. System requirements....................3 4.

More information

The zenterprise Unified Resource Manager IBM Corporation

The zenterprise Unified Resource Manager IBM Corporation The zenterprise Unified Resource Manager Agenda IBM zenterprise and The Unified Resource Manager Objectives Structure The Unified Resource Manager Functional Overview Overview of major functions Monitoring

More information

This option is only valid when backing up the data to a remote NFS file system. Display the help text for this command and exit.

This option is only valid when backing up the data to a remote NFS file system. Display the help text for this command and exit. NAME bkconsdata - back up console data SYNOPSIS bkconsdata -r {dvd ftp nfs} [-h host-name] [-u user-id] [--passwd password] [-l mount-resource-location] [-o "mount-command-options"] [--help] DESCRIPTION

More information

IBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version :

IBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version : IBM 000-180 p5 and pseries Enterprise Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-180 A. The LPAR Configuration backup is corrupt B. The LPAR Configuration

More information

CompTIA Linux+ Guide to Linux Certification Fourth Edition. Chapter 2 Linux Installation and Usage

CompTIA Linux+ Guide to Linux Certification Fourth Edition. Chapter 2 Linux Installation and Usage CompTIA Linux+ Guide to Linux Certification Fourth Edition Chapter 2 Linux Installation and Usage Objectives Prepare for and install Fedora Linux using good practices Outline the structure of the Linux

More information

Appliance Installation Guide

Appliance Installation Guide Appliance Installation Guide GWAVA 6.5 Copyright 2012. GWAVA Inc. All rights reserved. Content may not be reproduced without permission. http://www.gwava.com 1 Contents Overview... 2 Minimum System Requirements...

More information

3.5.5 Creating client partitions

3.5.5 Creating client partitions Example 3-27 Logical partitions are mapped to two physical partitions $ lsvg -lv rootvg rootvg: LV NAME TYPE LPs PPs PVs LV STATE MOUNT POINT hd5 boot 1 2 2 closed/syncd N/A hd6 paging 4 8 2 open/syncd

More information

Installing and Configuring the Hardware Management Console. ESCALA Power7 REFERENCE 86 A1 28FF 06

Installing and Configuring the Hardware Management Console. ESCALA Power7 REFERENCE 86 A1 28FF 06 Installing and Configuring the Hardware Management Console ESCALA Power7 REFERENCE 86 A1 28FF 06 Installing and Configuring the Hardware Management Console The ESCALA Power7 publications concern the following

More information

Cisco UCS C-Series. Installation Guide

Cisco UCS C-Series. Installation Guide Installation Guide UPDATED: 04 October 2018 Copyright Notices Copyright 2002-2018 KEMP Technologies, Inc. All rights reserved. KEMP Technologies and the KEMP Technologies logo are registered trademarks

More information

Planning and Sizing Virtualization

Planning and Sizing Virtualization Planning and Sizing Virtualization Jaqui Lynch Architect, Systems Engineer Mainline Information Systems http://www.circle4.com/papers/cmgvirt.pdf 1 What is Virtualization? Being able to dynamically move

More information

IBM System i5 520 Express Configurations Improved scalability, flexibility, and performance

IBM System i5 520 Express Configurations Improved scalability, flexibility, and performance Hardware Announcement January 3, 26 IBM System i5 52 Express Configurations Improved scalability, flexibility, and performance Overview System i5 52 Express Configurations, which provide ready-to-run,

More information

Sentry has been eliminated. Its functionality has been incorporated into Administrator through the use of views, events and the DBMS.

Sentry has been eliminated. Its functionality has been incorporated into Administrator through the use of views, events and the DBMS. 1 Performance: The overall default system performance is better than in v3.02 when the data is accessed via TCP. When the data is accessed using the new optional direct access method, the performance is

More information

IBM System p5 570 POWER5+ processor and memory features offer new options

IBM System p5 570 POWER5+ processor and memory features offer new options Hardware Announcement February 14, 2006 IBM System p5 570 POWER5+ processor and memory features offer new options Overview The System p5 570 offers new POWER5+ processor options with 64-bit 1.9 GHz and

More information

IBM i and related software Installing, upgrading, or deleting IBM i and related software

IBM i and related software Installing, upgrading, or deleting IBM i and related software IBM i IBM i and related software Installing, upgrading, or deleting IBM i and related software 7.1 SC41-5120-11 IBM i IBM i and related software Installing, upgrading, or deleting IBM i and related software

More information

IBM. Availability Implementing high availability. IBM i 7.1

IBM. Availability Implementing high availability. IBM i 7.1 IBM IBM i Availability Implementing high availability 7.1 IBM IBM i Availability Implementing high availability 7.1 Note Before using this information and the product it supports, read the information

More information

Application and Partition Mobility

Application and Partition Mobility IBM System p Application and Mobility Francis COUGARD IBM Products and Solutions Support Center Montpellier Copyright IBM Corporation 2009 Index Application and Mobility Presentation Videocharger and DB2

More information

IBM - C AIX 7 Administration Version: 7.1

IBM - C AIX 7 Administration Version: 7.1 IBM - C4040-221 AIX 7 Administration Version: 7.1 1 Topic 1, Volume A QUESTION: 1 The following information has been reported in an AIX error log: How can the administrator prevent the error from reoccurring?

More information

How to Deploy a Barracuda NG Vx using Barracuda NG Install on a VMware Hypervisor

How to Deploy a Barracuda NG Vx using Barracuda NG Install on a VMware Hypervisor How to Deploy a Barracuda NG Vx using Barracuda NG Install on a VMware Hypervisor The OVA package uses a default configuration that may not be suitable for your deployment. If you want to use multiple

More information

Redbooks Paper. IBM Eserver pseries High Performance Switch Installation

Redbooks Paper. IBM Eserver pseries High Performance Switch Installation Redbooks Paper Octavian Lascu Pablo Pereira Fernando Pizzano Zbigniew Borgosz Andrei Socolic Josh-Daniel Davis IBM Eserver pseries High Performance Installation For many years, IBM has been involved as

More information

Getting Started With Parallels Desktop 14

Getting Started With Parallels Desktop 14 Getting Started With Parallels Desktop 14 Parallels International GmbH Vordergasse 59 8200 Schaffhausen Switzerland Tel: + 41 52 672 20 30 www.parallels.com Copyright 1999-2018 Parallels International

More information

Exam : Title : Iseries system administration v5r2. Version : Demo

Exam : Title : Iseries system administration v5r2. Version : Demo Exam : 000-355 Title : Iseries system administration v5r2 Version : Demo 1. Users are reporting long response time delays in transactions that previously would run with sunscald response. The system administrator

More information

Exam : : System I Technical Solutions - Design (including i5/os V5R4) Title. Version : DEMO

Exam : : System I Technical Solutions - Design (including i5/os V5R4) Title. Version : DEMO Exam : 000-868 Title : System I Technical Solutions - Design (including i5/os V5R4) Version : DEMO 1.Which of the following System i 520 POWER5+ editions can be directly upgraded to an Enterprise Edition?

More information

Getting Started Guide. Installation and Setup Instructions. For version Copyright 2009 Code 42 Software, Inc. All rights reserved

Getting Started Guide. Installation and Setup Instructions. For version Copyright 2009 Code 42 Software, Inc. All rights reserved Installation and Setup Instructions For version 06.11.2009 Copyright 2009 Code 42 Software, Inc. All rights reserved About This Guide This guide shows you how to install, activate and back up with CrashPlan

More information

Table of Contents. Course Introduction. Table of Contents Getting Started About This Course About CompTIA Certifications. Module 1 / Server Setup

Table of Contents. Course Introduction. Table of Contents Getting Started About This Course About CompTIA Certifications. Module 1 / Server Setup Table of Contents Course Introduction Table of Contents Getting Started About This Course About CompTIA Certifications Module 1 / Server Setup Module 1 / Unit 1 Servers and Racks Server Hardware and Software

More information

Dell EMC PowerEdge Systems SUSE Linux Enterprise Server 15. Installation Instructions and Important Information

Dell EMC PowerEdge Systems SUSE Linux Enterprise Server 15. Installation Instructions and Important Information Dell EMC PowerEdge Systems SUSE Linux Enterprise Server 15 Installation Instructions and Important Information Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

WLM1200-RMTS User s Guide

WLM1200-RMTS User s Guide WLM1200-RMTS User s Guide Copyright 2011, Juniper Networks, Inc. 1 WLM1200-RMTS User Guide Contents WLM1200-RMTS Publication Suite........................................ 2 WLM1200-RMTS Hardware Description....................................

More information

MIMIX. Version 7.0 MIMIX Global Operations 5250

MIMIX. Version 7.0 MIMIX Global Operations 5250 MIMIX Version 7.0 MIMIX Global Operations 5250 Published: September 2010 level 7.0.01.00 Copyrights, Trademarks, and tices Contents Version 7.0 MIMIX Global Operations 5250 Who this book is for... 5 What

More information

Hardware Installation Guide Installation (x3350)

Hardware Installation Guide Installation (x3350) Title page Nortel Application Gateway 2000 Nortel Application Gateway Release 6.3 Hardware Installation Guide Installation (x3350) Document Number: NN42400-300 Document Release: Standard 04.03 Date: January

More information

Installing the Operating System or Hypervisor

Installing the Operating System or Hypervisor If you purchased E-Series Server or NCE Option 1 (E-Series Server or NCE without a preinstalled operating system or hypervisor), you must install an operating system or hypervisor. This chapter includes

More information

Forescout. Quick Installation Guide. Single Appliance. Version 8.1

Forescout. Quick Installation Guide. Single Appliance. Version 8.1 Forescout Version 8.1 Contact Information Forescout Technologies, Inc. 190 West Tasman Drive San Jose, CA 95134 USA https://www.forescout.com/support/ Toll-Free (US): 1.866.377.8771 Tel (Intl): 1.408.213.3191

More information