1 Quick reference guide Standard Frame Axial Fans 2007 Edition

2 about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic systems to process plant. Product range: Containing thousands of models; from miniature dc axials to large centrifugal fans. Stock availability: Thanks to our large modern warehouse facility containing an unparalleled variety of standard fans. Customised stock: Take advantage of our ability to build fans from stock components, modify standard products, or order specials to meet your precise requirements and your deadlines. Customer care : Take advantage of the partnership offered by Axair Fans; the friendly, approachable and efficient fan supplier. Most fans featured in this catalogue are available ex-stock or within short lead times. Please consult us for individual datasheets Model Referencing system Motor A.C. AC a.c. shaded pole motor, a.c. ac capacitor run induction motor dc d.c. brushless casing size 15x15 mm, 20x20mm, 25x25mm, 30x30mm, 35x35mm, 40x40mm, 45x45mm, 50x50mm, 60x60mm, 70x70mm, 80x80mm, 92x92mm, 120x120mm, 127x127mm, 172x150mm, Ø172mm 218x218mm 280x280mm axial fan casing thickness, voltage 5V d.c., 12V d.c., 24V d.c., 48V d.c., 115V a.c., 230V a.c., 400V a.c. 3 phase, Speed extra low, very low, low, medium, high, super high, Connection terminals terminal block, flat terminals, lead wires, bearing type shielded ball bearings, sleeve bearings, hypro bearings, Options, alarm output, speed signal output, variable speed with integrated thermistor, variable speed with external thermistor, digital PWM speed control, high temperature ambient, motor IP55 IP 55 protected, motor IP25 IP 25 protected, wires length, bi-directional flow, dual speed, humidity protected, auto restart shout-out type, waterproof 2 sales@axair-fans.co.uk

3 Drawings 3

4 DC Frame Fans Casing Black fibreglass reinforced PBT self extinguishing UL 94V-0 Motor Brushless external rotor motor with autorestart Impeller Fibreglass reinforced PBT or PA, self extinguishing UL 94V-0 Motor Protection By Impedance and polarity or by integrated circuit against locked rotor & polarity inversion Operating temperature Ball bearings -20 C C bearings -10 C +60 C Hypro bearings -10 C +60 C Ball bearings Options Lifetime L10 at 65% RH 70,000hrs at 40 C 50,000hrs at 40 C 70,000hrs at 40 C bearings Hypro bearings 40,000hrs at T max 35,000hrs at T max 40,000hrs at T max Third wire alarm detecting failure or locked rotor by IC, third wire speed signal detecting failure or abnormal rotation, internal or third wire external thermistor detecting air temperature for speed variation, digital PWM speed control, humidity protection, IP55 protection. Model Dimensions (mm) Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D20N04MWHA00 20x20x6.5 1 x D20N04LWHA00 20x20x6.5 1 x D20N01MWHA00 20x20x6.5 1 x D20N01LWHA00 20x20x6.5 1 x D20E04MWHA00 20x20x10 1 x D20E04MWBA00 20x20x10 1 x D20E04LWHA00 20x20x10 1 x D20E04LWBA00 20x20x10 1 x D20E01MWHA00 20x20x10 1 x D20E01MWBA00 20x20x10 1 x D20E01LWHA00 20x20x10 1 x D20E01LWBA00 20x20x10 1 x D02N04MWHA00 25x25x6.5 1 x D02N04LWHA00 25x25x6.5 1 x D02N01MWHA00 25x25x6.5 1 x D02N01LWHA00 25x25x6.5 1 x D02E04MWHZ00 25x25x10 1 x D02E04MWBZ00 25x25x10 1 x D02E04HWHZ00 25x25x10 1 x D02E04HWBZ00 25x25x10 1 x D02E01MWHZ00 25x25x10 1 x D02E01MWBZ00 25x25x10 1 x D02E01HWHZ00 25x25x10 1 x D02E01HWBZ00 25x25x10 1 x D03N04MWHA00 30x30x6.5 1 x D03N04LWHA00 30x30x6.5 1 x D03N01MWHA00 30x30x6.5 1 x D03N01LWHA00 30x30x6.5 1 x D03E04MWHA00 30x30x10 1 x D03E04MWBA00 30x30x10 1 x D03E04LWHA00 30x30x10 1 x D03E04LWBA00 30x30x10 1 x D03E01MWHA00 30x30x10 1 x D03E01MWBA00 30x30x10 1 x D03E01LWHA00 30x30x10 1 x D03E01LWBA00 30x30x10 1 x D35N04MWHA00 35x35x6.5 1 x D35N04LWHA00 35x35x6.5 1 x D35N01MWHA00 35x35x6.5 1 x D35N01LWHA00 35x35x6.5 1 x D04N04MWHA00 40x40x6.5 1 x D04N04HWHA00 40x40x6.5 1 x D04N01MWHA00 40x40x6.5 1 x D04N01HWHA00 40x40x6.5 1 x sales@axair-fans.co.uk

5 DC Frame Fans Model Dimensions (mm) Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D04E05MWST00 40x40x10 1 x D04E05MWHT00 40x40x10 1 x D04E05MWBT00 40x40x10 1 x D04E05HWST00 40x40x10 1 x D04E05HWHT00 40x40x10 1 x D04E05HWBT00 40x40x10 1 x D04E04MWST00 40x40x10 1 x D04E04MWHT00 40x40x10 1 x D04E04MWBT00 40x40x10 1 x D04E04HWST00 40x40x10 1 x D04E04HWHT00 40x40x10 1 x D04E04HWBT00 40x40x10 1 x D04E01MWST00 40x40x10 1 x D04E01MWHT00 40x40x10 1 x D04E01MWBT00 40x40x10 1 x D04E01HWST00 40x40x10 1 x D04E01HWHT00 40x40x10 1 x D04E01HWBT00 40x40x10 1 x D04F04MWSA00 40x40x15 1 x D04F04MWHA00 40x40x15 1 x D04F04MWBA00 40x40x15 1 x D04F04LWSA00 40x40x15 1 x D04F04LWHA00 40x40x15 1 x D04F04LWBA00 40x40x15 1 x D04F04HWSA00 40x40x15 1 x D04F04HWHA00 40x40x15 1 x D04F04HWBA00 40x40x15 1 x D04D05MWSZ00 40x40x20 1 x D04D05MWHZ00 40x40x20 1 x D04D05MWBZ00 40x40x20 1 x D04D05HWSZ00 40x40x20 1 x D04D05HWHZ00 40x40x20 1 x D04D05HWBZ00 40x40x20 1 x D04D04MWSZ00 40x40x20 1 x D04D04MWHZ00 40x40x20 1 x D04D04MWBZ00 40x40x20 1 x D04D04HWSZ00 40x40x20 1 x D04D04HWHZ00 40x40x20 1 x D04D04HWBZ00 40x40x20 1 x D45N04MWHA00 45x45x6.5 1 x D45N04HWHA00 45x45x6.5 1 x D45N01MWHA00 45x45x6.5 1 x D45N01HWHA00 45x45x6.5 1 x D45E04MWSA00 45x45x10 1 x D45E04MWHA00 45x45x10 1 x D45E04MWBA00 45x45x10 1 x D45E04HWSA00 45x45x10 1 x D45E04HWHA00 45x45x10 1 x D45E04HWBA00 45x45x10 1 x D45E01MWSA00 45x45x10 1 x D45E01MWHA00 45x45x10 1 x D45E01MWBA00 45x45x10 1 x D45E01HWSA00 45x45x10 1 x D45E01HWHA00 45x45x10 1 x D45E01HWBA00 45x45x10 1 x D50E04MWSA00 50x50x10 1 x D50E04MWHA00 50x50x10 1 x D50E04MWBA00 50x50x10 1 x D50E04LWSA00 50x50x10 1 x D50E04LWHA00 50x50x10 1 x D50E04LWBA00 50x50x10 1 x

6 DC Frame Fans Model Dimensions (mm) Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D50F04SWSA00 50x50x15 1 x D50F04SWHA00 50x50x15 1 x D50F04SWBA00 50x50x15 1 x D50F04MWSA00 50x50x15 1 x D50F04MWHA00 50x50x15 1 x D50F04MWBA00 50X50X15 1 x D50F04LWSA00 50x50x15 1 x D50F04LWHA00 50x50x15 1 x D50F04LWBA00 50x50x15 1 x D50F04HWSA00 50x50x15 1 x D50F04HWHA00 50x50x15 1 x D50F04HWBA00 50x50x15 1 x D06E04MWST00 60x60x10 1 x D06E04MWHT00 60x60x10 1 x D06E04MWBT00 60x60x10 1 x D06E04HWST00 60x60x10 1 x D06E04HWHT00 60x60x10 1 x D06E04HWBT00 60x60x10 1 x D06E01MWST00 60x60x10 1 x D06E01MWHT00 60x60x10 1 x D06E01MWBT00 60x60x10 1 x D06E01HWST00 60x60x10 1 x D06E01HWHT00 60x60x10 1 x D06E01HWBT00 60x60x10 1 x D06F05MWSA00 60x60x15 1 x D06F05MWHA00 60x60x15 1 x D06F05MWBA00 60x60x15 1 x D06F05HWSA00 60x60x15 1 x D06F05HWHA00 60x60x15 1 x D06F05HWBA00 60x60x15 1 x D06F04MWSA00 60x60x15 1 x D06F04MWHA00 60x60x15 1 x D06F04MWBA00 60x60x15 1 x D06F04HWSA00 60x60x15 1 x D06F04HWHA00 60x60x15 1 x D06F04HWBA00 60x60x15 1 x D06F01MWSA00 60x60x15 1 x D06F01MWHA00 60x60x15 1 x D06F01MWBA00 60x60x15 1 x D06F01HWSA00 60x60x15 1 x D06F01HWHA00 60x60x15 1 x D06F01HWBA00 60x60x15 1 x D06D05MWSA00 60x60x20 1 x D06D05MWHA00 60x60x20 1 x D06D05MWBA00 60x60x20 1 x D06D05LWSA00 60x60x20 1 x D06D05LWHA00 60x60x20 1 x D06D05LWBA00 60x60x20 1 x D06D05HWSA00 60x60x20 1 x D06D05HWHA00 60x60x20 1 x D06D05HWBA00 60x60x20 1 x D06D04MWSA00 60x60x20 1 x D06D04MWHA00 60x60x20 1 x D06D04MWBA00 60x60x20 1 x D06D04LWSA00 60x60x20 1 x D06D04LWHA00 60x60x20 1 x D06D04LWBA00 60x60x20 1 x D06D04HWSA00 60x60x20 1 x D06D04HWHA00 60x60x20 1 x D06D04HWBA00 60x60x20 1 x sales@axair-fans.co.uk

7 Model Dimensions (mm) DC Frame Fans Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D06A05SWSA00 60x60x25 1 x D06A05SWHA00 60x60x25 1 x D06A05SWBA00 60x60x25 1 x D06A05MWSA00 60x60x25 1 x D06A05MWHA00 60x60x25 1 x D06A05MWBA00 60x60x25 1 x D06A05LWSA00 60x60x25 1 x D06A05LWHA00 60x60x25 1 x D06A05LWBA00 60x60x25 1 x D06A05HWSA00 60x60x25 1 x D06A05HWHA00 60x60x25 1 x D06A05HWBA00 60x60x25 1 x D06A04SWSA00 60x60x25 1 x D06A04SWHA00 60x60x25 1 x D06A04SWBA00 60x60x25 1 x D06A04MWSA00 60x60x25 1 x D06A04MWHA00 60x60x25 1 x D06A04MWBA00 60x60x25 1 x D06A04LWSA00 60x60x25 1 x D06A04LWHA00 60x60x25 1 x D06A04LWBA00 60x60x25 1 x D06A04HWSA00 60x60x25 1 x D06A04HWHA00 60x60x25 1 x D06A04HWBA00 60x60x25 1 x D07A05MWSA00 70x70x25 1 x D07A05MWHA00 70x70x25 1 x D07A05MWBA00 70x70x25 1 x D07A05HWSA00 70x70x25 1 x D07A05HWHA00 70x70x25 1 x D07A05HWBA00 70x70x25 1 x D07A04MWSA00 70x70x25 1 x D07A04MWHA00 70x70x25 1 x D07A04MWBA00 70x70x25 1 x D07A04HWSA00 70x70x25 1 x D07A04HWHA00 70x70x25 1 x D07A04HWBA00 70x70x25 1 x D08F05MWSA00 80x80x15 1 x D08F05MWHA00 80x80x15 1 x D08F05MWBA00 80x80x15 1 x D08F05HWSA00 80x80x15 1 x D08F05HWHA00 80x80x15 1 x D08F05HWBA00 80x80x15 1 x D08F04MWSA00 80x80x15 1 x D08F04MWHA00 80x80x15 1 x D08F04MWBA00 80x80x15 1 x D08F04HWSA00 80x80x15 1 x D08F04HWHA00 80x80x15 1 x D08F04HWBA00 80x80x15 1 x D08F01MWSA00 80x80x15 1 x D08F01MWHA00 80x80x15 1 x D08F01MWBA00 80x80x15 1 x D08F01HWSA00 80x80x15 1 x D08F01HWHA00 80x80x15 1 x D08F01HWBA00 80x80x15 1 x

8 DC Frame Fans Model Dimensions (mm) Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D08D05MWSA00 80x80x20 1 x D08D05MWHA00 80x80x20 1 x D08D05MWBA00 80x80x20 1 x D08D05HWSA00 80x80x20 1 x D08D05HWHA00 80x80x20 1 x D08D05HWBA00 80x80x20 1 x D08D04MWSA00 80x80x20 1 x D08D04MWHA00 80x80x20 1 x D08D04MWBA00 80x80x20 1 x D08D04HWSA00 80x80x20 1 x D08D04HWHA00 80x80x20 1 x D08D04HWBA00 80x80x20 1 x D08A05SWSA00 80x80x25 1 x D08A05SWHA00 80x80x25 1 x D08A05SWBA00 80x80x25 1 x D08A05MWSA00 80x80x25 1 x D08A05MWHA00 80x80x25 1 x D08A05MWBA00 80x80x25 1 x D08A05LWSA00 80x80x25 1 x D08A05LWHA00 80x80x25 1 x D08A05LWBA00 80x80x25 1 x D08A05HWSA00 80x80x25 1 x D08A05HWHA00 80x80x25 1 x D08A05HWBA00 80x80x25 1 x D08A04SWSA00 80x80x25 1 x D08A04SWHA00 80x80x25 1 x D08A04SWBA00 80x80x25 1 x D08A04MWSA00 80x80x25 1 x D08A04MWHA00 80x80x25 1 x D08A04MWBA00 80x80x25 1 x D08A04LWSA00 80x80x25 1 x D08A04LWHA00 80x80x25 1 x D08A04LWBA00 80x80x25 1 x D08A04HWSA00 80x80x25 1 x D08A04HWHA00 80x80x25 1 x D08A04HWBA00 80x80x25 1 x D09D05MWSA00 92x92x20 1 x D09D05MWHA00 92x92x20 1 x D09D05MWBA00 92x92x20 1 x D09D05HWSA00 92x92x20 1 x D09D05HWHA00 92x92x20 1 x D09D05HWBA00 92x92x20 1 x D09D04MWSA00 92x92x20 1 x D09D04MWHA00 92x92x20 1 x D09D04MWBA00 92x92x20 1 x D09D04HWSA00 92x92x20 1 x D09D04HWHA00 92x92x20 1 x D09D04HWBA00 92x92x20 1 x sales@axair-fans.co.uk

9 DC Frame Fans Model Dimensions (mm) Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D09A05SWSZ00 92x92x25 1 x D09A05SWHZ00 92x92x25 1 x D09A05SWBZ00 92x92x25 1 x D09A05MWSZ00 92x92x25 1 x D09A05MWHZ00 92x92x25 1 x D09A05MWBZ00 92x92x25 1 x D09A05LWSZ00 92x92x25 1 x D09A05LWHZ00 92x92x25 1 x D09A05LWBZ00 92x92x25 1 x D09A05HWSZ00 92x92x25 1 x D09A05HWHZ00 92x92x25 1 x D09A05HWBZ00 92x92x25 1 x D09A04SWSZ00 92x92x25 1 x D09A04SWHZ00 92x92x25 1 x D09A04SWBZ00 92x92x25 1 x D09A04MWSZ00 92x92x25 1 x D09A04MWHZ00 92x92x25 1 x D09A04MWBZ00 92x92x25 1 x D09A04LWSZ00 92x92x25 1 x D09A04LWHZ00 92x92x25 1 x D09A04LWBZ00 92x92x25 1 x D09A04HWSZ00 92x92x25 1 x D09A04HWHZ00 92x92x25 1 x D09A04HWBZ00 92x92x25 1 x D12A05SWSZ00 120x120x25 1 x D12A05SWHZ00 120x120x25 1 x D12A05SWBZ00 120x120x25 1 x D12A05MWSZ00 120x120x25 1 x D12A05MWHZ00 120x120x25 1 x D12A05MWBZ00 120x120x25 1 x D12A05LWSZ00 120x120x25 1 x D12A05LWHZ00 120x120x25 1 x D12A05LWBZ00 120x120x25 1 x D12A05HWSZ00 120x120x25 1 x D12A05HWHZ00 120x120x25 1 x D12A05HWBZ00 120x120x25 1 x D12A04SWSZ00 120x120x25 1 x D12A04SWHZ00 120x120x25 1 x D12A04SWBZ00 120x120x25 1 x D12A04MWSZ00 120x120x25 1 x D12A04MWHZ00 120x120x25 1 x D12A04MWBZ00 120x120x25 1 x D12A04LWSZ00 120x120x25 1 x D12A04LWHZ00 120x120x25 1 x D12A04LWBZ00 120x120x25 1 x D12A04HWSZ00 120x120x25 1 x D12A04HWHZ00 120x120x25 1 x D12A04HWBZ00 120x120x25 1 x

10 DC Frame Fans Model Dimensions (mm) Drawing system Rated voltage Rated power Max air flow ise Hypro Ball V d.c. W m3/h db(a) D12G07HWSA00 120x120x32 1 x D12G07HWHA00 120x120x32 1 x D12G07HWBA00 120x120x32 1 x D12G05MWSA00 120x120x32 1 x D12G05MWHA00 120x120x32 1 x D12G05MWBA00 120x120x32 1 x D12G05LWSA00 120x120x32 1 x D12G05LWHA00 120x120x32 1 x D12G05LWBA00 120x120x32 1 x D12G05HWSA00 120x120x32 1 x D12G05HWHA00 120x120x32 1 x D12G05HWBA00 120x120x32 1 x D12G04MWSA00 120x120x32 1 x D12G04MWHA00 120x120x32 1 x D12G04MWBA00 120x120x32 1 x D12G04LWSA00 120x120x32 1 x D12G04LWHA00 120x120x32 1 x D12G04LWBA00 120x120x32 1 x D12G04HWSA00 120x120x32 1 x D12G04HWHA00 120x120x32 1 x D12G04HWBA00 120x120x32 1 x D12B07MWSZ00 120x120x38 1 x D12B07MWHZ00 120x120x38 1 x D12B07MWBZ00 120x120x38 1 x D12B07LWSZ00 120x120x38 1 x D12B07LWHZ00 120x120x38 1 x D12B07LWBZ00 120x120x38 1 x D12B07HWSZ00 120x120x38 1 x D12B07HWHZ00 120x120x38 1 x D12B07HWBZ00 120x120x38 1 x D12B07HWBA00 120x120x38 1 x D12B05SWSZ00 120x120x38 1 x D12B05SWHZ00 120x120x38 1 x D12B05SWBZ00 120x120x38 1 x D12B05MWSZ00 120x120x38 1 x D12B05MWHZ00 120x120x38 1 x D12B05MWBZ00 120x120x38 1 x D12B05LWSZ00 120x120x38 1 x D12B05LWHZ00 120x120x38 1 x D12B05LWBZ00 120x120x38 1 x D12B05HWSZ00 120x120x38 1 x D12B05HWHZ00 120x120x38 1 x D12B05HWBZ00 120x120x38 1 x D12B05HWBA00 120x120x38 1 x D12B04SWSZ00 120x120x38 1 x D12B04SWHZ00 120x120x38 1 x D12B04SWBZ00 120x120x38 1 x D12B04MWSZ00 120x120x38 1 x D12B04MWHZ00 120x120x38 1 x D12B04MWBZ00 120x120x38 1 x D12B04LWSZ00 120x120x38 1 x D12B04LWHZ00 120x120x38 1 x D12B04LWBZ00 120x120x38 1 x D12B04HWSZ00 120x120x38 1 x D12B04HWHZ00 120x120x38 1 x D12B04HWBZ00 120x120x38 1 x D17C07HWBY00 172x150x51 5 x D17C05HWBY00 172x150x51 5 x D17C04HWBY00 172x150x51 5 x D22S07HKBD00 218x218x83 7 x D22S05HKBD00 218x218x83 7 x sales@axair-fans.co.uk

11 AC Frame Fans Casing Black die cast aluminium alloy Motor Shaded pole or capacitor run Impeller Fibreglass reinforced PBT or PA, self extinguishing UL 94V-0 Motor Protection By Impedance or thermally Operating temperature Ball bearings -40 C C bearings -10 C +60 C Ball bearings Options Lifetime L10 at 65% RH 40000hrs at 40 C 30000hrs at 40 C bearings 20000hrs at T max 15000hrs at T max IP55 protected, high temperature resistant, bi-directional flow, fans with steel impeller, special voltages Model Dimensions (mm) Drawing system Rated voltage Freq. Rated power Max air flow ise Ball V a.c. Hz W m 3 /h db(a) A06G12HWBF00 60x60x30 1 x /60 5.0/ / /28.0 A06G23HWBF00 60x60x30 1 x /60 5.0/ / /28.0 A08A12HWBF00 80x80x25 1 x /60 16/14 30/ /35.0 A08A12HWSF00 80x80x25 1 x /60 16/14 30/ /35.0 A08A12MWBF00 80x80x25 1 x /60 16/14 28/ /34.0 A08A12MWSF00 80x80x25 1 x /60 16/14 28/ /34.0 A08A12SWBY00 80x80x25 1 x /60 9.0/8.0 35/ /35.0 A08A12SWSY00 80x80x25 1 x /60 9.0/8.0 35/ /35.0 A08A23HWBF00 80x80x25 1 x /60 16/14 30/ /35.0 A08A23HWSF00 80x80x25 1 x /60 16/14 30/ /35.0 A08A23MWBF00 80x80x25 1 x /60 16/14 28/ /34.0 A08A23MWSF00 80x80x25 1 x /60 16/14 28/ /34.0 A08A23SWBY00 80x80x25 1 x /60 9.0/8.0 35/ /35.0 A08A23SWSY00 80x80x25 1 x /60 9.0/8.0 35/ /35.0 A08B12HWBF00 80x80x38 1 x / / /36.0 A08B12HWSF00 80x80x38 1 x / / /36.0 A08B12LWBF00 80x80x38 1 x / / /32.0 A08B12LWSF00 80x80x38 1 x / / /32.0 A08B12MWBF00 80x80x38 1 x / / /33.0 A08B12MWSF00 80x80x38 1 x / / /33.0 A08B12SWBY00 80x80x38 1 x /60 9.0/8.0 46/ /38.0 A08B12SWSY00 80x80x38 1 x /60 9.0/8.0 46/ /38.0 A08B23HWBF00 80x80x38 1 x / / /36.0 A08B23HWSF00 80x80x38 1 x / / /36.0 A08B23LWBF00 80x80x38 1 x / / /32.0 A08B23LWSF00 80x80x38 1 x / / /32.0 A08B23MWBF00 80x80x38 1 x / / /33.0 A08B23MWSF00 80x80x38 1 x / / /33.0 A08B23SWBY00 80x80x38 1 x /60 9.0/8.0 46/ /38.0 A08B23SWSY00 80x80x38 1 x /60 9.0/8.0 46/ /38.0 A09A12HTBF00 92x92x25 4 x /60 16/14 50/ /36.0 A09A12HTSF00 92x92x25 4 x /60 16/14 50/ /36.0 A09A12MTBF00 92x92x25 4 x /60 16/14 43/ /33.0 A09A12MTSF00 92x92x25 4 x /60 16/14 43/ /33.0 A09A12STBY00 92x92x25 4 x /60 12/9.0 55/ /38.0 A09A12STSY00 92x92x25 4 x /60 12/9.0 55/ /38.0 A09A23HTBF00 92x92x25 4 x /60 16/14 50/ /36.0 A09A23HTSF00 92x92x25 4 x /60 16/14 50/ /36.0 A09A23MTBF00 92x92x25 4 x /60 16/14 43/ /33.0 A09A23MTSF00 92x92x25 4 x /60 16/14 43/ /33.0 A09A23STBY00 92x92x25 4 x /60 12/9.0 55/ /38.0 A09A23STSY00 92x92x25 4 x /60 12/9.0 55/ /38.0 A09B12HWBY00 92x92x38 1 x /60 9.0/8.0 64/ /38.0 A09B12HWSY00 92x92x38 1 x /60 9.0/8.0 64/ /38.0 A09B12SWBY00 92x92x38 1 x / / /43.0 A09B12SWSY00 92x92x38 1 x / / /43.0 A09B23HWBY00 92x92x38 1 x /60 9.0/8.0 64/ /38.0 A09B23HWSY00 92x92x38 1 x /60 9.0/8.0 64/ /38.0 A09B23SWBY00 92x92x38 1 x / / /43.0 A09B23SWSY00 92x92x38 1 x / / /

12 AC Frame Fans Model Dimensions (mm) Drawing system Rated voltage Freq. Rated power Max air flow ise Ball V a.c. Hz W m 3 /h db(a) A12A12HTBF00 120x120x25 4 x /60 16/14 100/ /42.0 A12A12HTSF00 120x120x25 4 x /60 16/14 100/ /42.0 A12A12MTBF00 120x120x25 4 x /60 16/14 90/ /33.0 A12A12MTSF00 120x120x25 4 x /60 16/14 90/ /33.0 A12A12STBY00 120x120x25 4 x / / /44.0 A12A12STSY00 120x120x25 4 x / / /44.0 A12A23HTBF00 120x120x25 4 x /60 16/14 100/ /42.0 A12A23HTSF00 120x120x25 4 x /60 16/14 100/ /42.0 A12A23MTBF00 120x120x25 4 x /60 16/14 90/ /33.0 A12A23MTSF00 120x120x25 4 x /60 16/14 90/ /33.0 A12A23STBY00 120x120x25 4 x / / /44.0 A12A23STSY00 120x120x25 4 x / / /44.0 A12B05HTBW00 119x119x38 4 x 24 50/60 15/16 150/ /44.5 A12B05HTSW00 119x119x38 4 x 24 50/60 15/16 150/ /44.5 A12B12STBW00 119x119x38 4 x /60 22/20 165/ /46.0 A12B12STSW00 119x119x38 4 x /60 22/20 165/ /46.0 A12B12HTBW00 119x119x38 4 x /60 20/18 144/ /48.0 A12B12HTSW00 119x119x38 4 x /60 20/18 144/ /48.0 A12B12MTBW00 119x119x38 4 x /60 16/16 130/ /41.0 A12B12MTSW00 119x119x38 4 x /60 16/16 130/ /41.0 A12B12VTBW00 119x119x38 4 x /60 10/10 98/ /35.0 A12B12VTSW00 119x119x38 4 x /60 10/10 98/ /35.0 A12R12HTBW00 119x119x38 4 x /60 19/18 140/ /45.0 A12R12HTSW00 119x119x38 4 x /60 19/18 140/ /45.0 A12B23STBW00 119x119x38 4 x /60 22/21 165/ /46.0 A12B23STSW00 119x119x38 4 x /60 22/21 165/ /46.0 A12B23HTBW00 119x119x38 4 x /60 20/19 144/ /44.5 A12B23HTSW00 119x119x38 4 x /60 20/19 144/ /44.5 A12B23MTBW00 119x119x38 4 x /60 16/15 130/ /41.0 A12B23MTSW00 119x119x38 4 x /60 16/15 130/ /41.0 A12B23LTBW00 119x119x38 4 x / / /39.0 A12B23LTSW00 119x119x38 4 x / / /39.0 A12B23VTBW00 119x119x38 4 x /60 10/10 98/ /35.0 A12B23VTSW00 119x119x38 4 x /60 10/10 98/ /35.0 A12B23ETBW00 119x119x38 4 x /60 6.5/6.0 83/ /27.5 A12B23ETSW00 119x119x38 4 x /60 6.5/6.0 83/ /27.5 A12R23HTBW00 119x119x38 4 x /60 18/18 140/ /45.0 A12R23HTSW00 119x119x38 4 x /60 18/18 140/ /45.0 A12W12HWBW00 Ø 113x38 3 x /60 20/18 144/ /44.5 A12W12HWSW00 Ø 113x38 3 x /60 20/18 144/ /44.5 A12W23HWBW00 Ø 113x38 3 x /60 20/18 144/ /44.5 A12W23HWSW00 Ø 113x38 3 x /60 20/18 144/ /44.5 A12Z12HWBW00 Ø 113x38 3 x /60 20/18 144/ /44.5 A12Z12HWSW00 Ø 113x38 3 x /60 20/18 144/ /44.5 A12Z23HWBW00 Ø 113x38 3 x /60 20/19 144/ /44.5 A12Z23HWSW00 Ø 113X38 3 x /60 20/19 144/ /44.5 A13B12HTBY00 127x127x38 4 x /60 23/21 188/ /48.0 A13B12HTSY00 127x127x38 4 x /60 23/21 188/ /48.0 A13B23HTBY00 127x127x38 4 x /60 23/21 188/ /48.0 A13B23HTSY00 127x127x38 4 x /60 23/21 188/ /48.0 C17B12HTBF00 172x150x38 5 x /60 27/28 300/ /57.0 C17B23HTBF00 172x150x38 5 x /60 27/28 300/ /57.0 A17C12HWBP00 172x150x51 5 x /60 37/34 300/ /51.0 A17C23HWBP00 172x150x51 5 x /60 37/34 300/ /51.0 C17C12HTBF00 172x150x51 5 x /60 29/30 330/ /58.0 C17C23HTBF00 172x150x51 5 x /60 29/30 330/ /58.0 C18C12HTBF00 Ø 172x51 6 x /60 29/30 330/ /55.0 C18C23HTBF00 Ø 172x51 6 x /60 29/30 330/ /55.0 C22S12HKBD00 218x218x83 7 x /60 70/75 812/ /63.0 C22S23HKBD00 218x218x83 7 x /60 70/75 812/ /63.0 C22S40HKBD00 218x218x83 7 x /60 71/ / / sales@axair-fans.co.uk

13 All Metal Frame Fans Casing Black die cast aluminium alloy Motor Shaded pole or capacitor run Impeller Black painted steel Motor Protection By Impedance or thermally Operating temperature Ball bearings -40 C +70 C Lifetime L10 at 65% RH Ball bearings 40,000hrs at 40 C 20,000hrs at T max Options Special voltages Model External dimensions Drawing system Rated voltage Freq. Rated power Max air flow ise V a.c. Hz W m 3 /h db(a) A09B12HWBM00 92x92x38 1 Ball /60 12/11 75/ /42.0 A09B23HWBM00 92x92x38 1 Ball /60 12/11 75/ /42.0 A12B12HTBM00 120x120x38 4 Ball /60 17/15 151/ /46.0 A12B12LTBM00 120x120x38 4 Ball /60 12/10 107/ /35.0 A12B23HTBM00 120x120x38 4 Ball /60 17/15 151/ /46.0 A12B23LTBM00 120x120x38 4 Ball /60 12/10 107/ /35.0 A17M12SWBM00 172x150x55 2 Ball /60 42/42 332/ /53.0 A17M23SWBM00 172x150x55 2 Ball /60 42/42 332/ /53.0 A17T12SWBM00 172x150x55 2 Ball /60 45/45 383/ /61.0 A17T23SWBM00 172x150x55 2 Ball /60 45/45 383/ /61.0 C25S12HKBE00 280x280x80 7 Ball /60 107/ / /70.0 C25S23HKBE00 280x280x80 7 Ball /60 114/ / /70.0 C25S40HKBE00 280x280x80 7 Ball /60 93/ / /69.0 Also available on request : Standard DC blowers IP 55 AC frame fans IP25 and IP55 DC frame fans High temperature AC frame fans All metal DC frame fans Please consult Axair Fans UK limited for more information Other Frame Fans Accessories for Frame Fans Metal finger guards Plastic finger guards Fast assembly plastic fan guards Plastic filters Metal EMC filters Elastic rivets / Plastic rivets Fan power leads 12

14 ALSO AVAILABLE FROM AXAIR FANS... CENTRIFUGAL FAN - LOW PRESSURE Up to Ø300 forward curved impeller Air flow rates to 12000m³/h Pressures to 470 Pascals IP55 protected motor with IP65 terminal box IN-LINE DUCT FANS - PLAS- TIC CASING Up to Ø315 inlet & discharge spigot Air flow rates to 1725m³/h External rotor motor - Single phase Accessories available AXIAL FANS - PLATE MOUNTED & CASED Up to Ø630 impeller Single & three phase versions Air flow rates to 18700m³/h IP65 motors duct & hosed water protection CENTRIFUGAL FANS - MEDIUM PRESSURE Up to Ø500 forward curved impeller Air flow rates to 11000m³/h Pressures to 3300 Pascals IP54 & IP55 totally enclosed motors Air stream temperature to 120 C CENTRIFUGAL FANS - POLYPROPYLENE Inlet & discharge spigots Up to Ø315 Air Flow rates to 1000m³/h Pressures to 2000Pascals Designed for laboratory fume cupboards and special outdoor installations FAN FILTER UNITS - ENCLOSURE VENTILATION Designed for control panels Air flow rates to 680m³/h Single phase, three phase & dc fan types Protection class IP43, IP54 or IP55 Screw & snap fit louvers, roof mounted version CENTRIFUGAL FANS - LOW PROFILE Single & double inlet Up to Ø560 forward curved impeller Air flow rates to 25000m³/h External rotor motor - Dimensionally compact Speed controllable AXIAL FANS - EPSILON LOW NOISE Up to Ø1000 sickle bladed impeller Air flow rates to 23000m³/h High efficiency, low noise Plate or guard mounting Axair Fans UK Limited declares that : The technical information provided in the brochure is for guidance only. For confirmation of the exact product specification please request data sheets. Technical advice and support are offered by the company in good faith. It remains for the purchaser to verify that the selected fans and accessories are entirely suitable for intended purpose. The products described in this brochure are designed to be assembled into equipment. They should only be handled by personnel who are qualified, trained and competent to install fans and electric motors. AXAIR FANS UK Ltd Lowfield Drive - Centre Wolstanton - Newcastle-under-Lyme - ST5 0UU Tel : Fax : sales@axair-fans.co.uk Visit our website : All specifications, data and drawings are subject to alterations without prior notice

Personal Service Global Reach

Personal Service Global Reach Personal Service Global Reach FAN MOTORS NMB Technologies Corporation (NMB Technologies Corporation Chatsworth, California) NMB Technologies Corporation is a subsidiary of NMB (USA) Inc., the North American

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac K3G-AP25-1 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County

More information

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS THINGS HAVE CHANGED, AND SO HAVE VENTILATION SYSTEMS. WALL SYSTEM HATCH SOLUTIONS ROOF SYSTEM A NEW CONCEPT IN HATCH VENTILATION SYSTEMS.

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AS8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

CFM-9225V XX - CXX

CFM-9225V XX - CXX date 7/1/217 page 1 of 1 SERIES: CFM-2V DESCRIPTION: DC AXIAL FAN FEATURES omnicool TM bearing system 2 x 2 mm frame multiple speed options for different cooling needs tachometer signal and rotation detect

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG8-AU6-B ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-746 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

EC axial fan - HyBlade

EC axial fan - HyBlade WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General

More information

1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack.

1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack. T Accessories n Subrack Cooling n Vertical Cooling From Bottom To Top D 1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack. 2 Vertical forced

More information

EC/AC centrifugal fans - RadiCal

EC/AC centrifugal fans - RadiCal EC/C centrifugal fans - RadiCal version 0/0 The engineer s choice The new RadiCal centrifugal fans Impellers made of one piece of plastic with an optimised flow channel, combined with a proven single-phase

More information

Verderflex. Vantage Description. Your benefits. Technical specifications. Materials

Verderflex. Vantage Description. Your benefits. Technical specifications. Materials Description The new Verderflex cased drive peristaltic pump accurately doses liquids at pressures exceeding 7 Bar for industries ranging from the aseptic, pharmaceutical environment to the harsh requirements

More information

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

C5 Series Stainless Steel Photoelectric

C5 Series Stainless Steel Photoelectric C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

AVM 321, 322: Valve actuator

AVM 321, 322: Valve actuator Product data sheet 4.1 51.374 AVM 321, 322: Valve actuator How energy efficiency is improved Automatic adaptation to valve, optimal operator convenience, precision activation and high energy efficiency

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and

More information

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range

More information

SUBMINIATURE MICROSWITCHES - SEALED

SUBMINIATURE MICROSWITCHES - SEALED SWITCHES.COUZET.COM MICOSWITCHES SUBMINIATUE MICOSWITCHES - SEALED VS - 88 Coil spring snap-action mechanism Wire lead or cable outputs, various terminal types with symmetric or asymmetric pinning Excellent

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available 8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming

More information

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General

More information

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

Compact Inductive Proximity Sensor

Compact Inductive Proximity Sensor SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS Series Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase V- 5Hz

More information

MEVDC2 MULTI POINT E X T R A C T

MEVDC2 MULTI POINT E X T R A C T TE CHI C A I FORM AT IO MUTI POIT E X T R A C T A QUIET, EERGY EFFICIET, OW DEPTH CETRA EXTRACT SYSTEM. SAP Q RECOGISED. TE CHI C A I FORM AT IO B E E F I T S MEETS BUIDIG REGUATIOS SAP Appendix Q recognised.

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

Centrifugal Fans direct driven. Issue 1

Centrifugal Fans direct driven. Issue 1 Centrifugal Fans direct driven ssue 1 1 Nicotra Gebhardt technologies like... utomated manufacture of compact scroll and impeller with forward curved blades Own C and Brushless-DC motor production for

More information

EC centrifugal fan - RadiPac

EC centrifugal fan - RadiPac R3G31-AX54-21 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet NKQ24A- SuperCap rotary actuator with emergency control function and extended functionalities for adjusting dampers in technical building installations and in laboratories Air damper

More information

MV Series AC Powered Photoelectric Sensors

MV Series AC Powered Photoelectric Sensors MV Series AC Powered Photoelectric M18 (18 mm) plastic- AC 12 models available Diffuse, polarized reflective, and through-beam models Plastic housing Axial cable or M12 quick-disconnect models Operates

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner GB Product Data Sheet 99.70.06-B AVM321S/AVM322S: 1000N Actuator with analog SUT positioner Areas of use For actuation of 2- and 3-way valves. For controllers with constant output (0...10 V / 4...20 ma)

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

InReg Volume flow controller Pa

InReg Volume flow controller Pa InReg Volume flow controller 0...300 Pa Electrical volume flow controller (CAV / VAV) for use in safe areas 24 VAC / DC supply, adaptive PID controller, alarm contact InReg - V... InReg - V... - A InReg

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2 > For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * * 09005318 DB_EN_DE44_LCD Rev. ST4-C 07/17 *09005318* Datasheet DE44 Digital 2-channel differential pressure switch/transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und

More information

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are

More information

P216. Condenser fan speed controller. Product bulletin. Features

P216. Condenser fan speed controller. Product bulletin. Features P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NKA-DKC L Modulating SuperCap rotary actuator with emergency control function and extended functionalities for adjusting dampers in technical building installations and in laboratories

More information

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V 4 666 OpenAir TM Air damper actuators Linear version, modulating, AC 24 V GBB16...2 Electromotive linear actuators, DC 0...10 V modulating control signal, nominal force 440 N, operating voltage AC 24 V,

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO

Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO CMRS-X Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857. Fan: Sheet steel casing. Impeller with reaction blades

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

SAFETY COMMAND DEVICES

SAFETY COMMAND DEVICES SAFETY COMMAND DEVICES ESB200, ESB210 E-Stop button Installation variant of the ESB200 Safety Command Device (without housing), e.g., in control panels on handling or tool machines for stopping dangerous

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS HV-STYLVENT Series 688 679 Shutter Reversible Natural ventilation position Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

Fan: Sheet steel casing. Impeller with reaction blades in extremely robust sheet steel. Motor assembled on the general bench.

Fan: Sheet steel casing. Impeller with reaction blades in extremely robust sheet steel. Motor assembled on the general bench. CASB-X Belt-driven, high pressure fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857. Fan: Sheet steel casing. Impeller with

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han

More information

Devices raised mounting

Devices raised mounting Devices raised mounting Illuminated actuator pushbutton Front protection Switching system Ø 29 mm Contacts Typ-Nr. e Illuminated actuator pushbutton IP 67 LL 1 NC - MA UT 14-476.36 1 4 17 12.15 M UT 14-436.36

More information

Multi-range pressure and differential pressure transmitter

Multi-range pressure and differential pressure transmitter Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

LA Series In-line Linear Actuators

LA Series In-line Linear Actuators LA Series In-line Linear Actuators Innovative, patented design for better life High quality, CE marked 6 size in diameter available: 16mm, 26mm, 35mm, 38mm, 45mm, 52mm High load capacity with precision

More information

Laserlyte Alignment System

Laserlyte Alignment System Laserlyte Alignment System A Global Laser Brand The LaserLyte alignment system is a unique, user adjustable, plug and play system suitable for a wide range of applications, i.e. alignment and these applications

More information

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor echnical data sheet GK4A- Damper actuator with capacitor technology for adjusting air dampers with emergency control function and extended functionalities in ventilation and airconditioning systems for

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

FE Series Photoelectric Sensors

FE Series Photoelectric Sensors FE Series Photoelectric Mini-rectangular plastic - DC 2 models available Diffuse, polarized reflective, and through-beam models Plastic housing Axial cable or M8 quick-disconnect models NPN or PNP, Light-on/Dark-on

More information

3000 series Premium Hall effect joysticks

3000 series Premium Hall effect joysticks The 3000 Series is the very latest generation in high precision contactless joysticks. With a class leading installed depth of

More information

EPIC Circular Connectors CIRCON M23 Series

EPIC Circular Connectors CIRCON M23 Series The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors

More information

Pressure switch Type KP

Pressure switch Type KP MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch Type KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high

More information

AC Induction Servomotors

AC Induction Servomotors AC Induction Servomotors HDP Series, axis height H00, H, H60, H00 from to 70 kw Technical catalogue 607/0 Contents Digit 6 7 8 9 0 6 7 Type structure: C M 0 0 0 0 0 0 0 A 0 0 0 Type of motor IP HDP C Pos.

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor echnical data sheet GK24A-SR Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building

More information

SIGUARD Safety Systems Safety Integrated

SIGUARD Safety Systems Safety Integrated SE 10 / SE. 00 / SE. 4 / SE. 5 Molded plastic / metal enclosure with separate actuator Application Safety interlock switches (limit switches) with separate actuator are used where the position of doors,

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage

More information

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT

More information

09. DIN CONNECTORS

09. DIN CONNECTORS . 41 612 CONNECTORS Connectors that comply with 41 612 have been in use for years for both board-to-board applications and cable-to-board applications. Their robustness and universality are legendary.

More information

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle 74673 Mulfingen Phone: +49 7938 81-0 Fax: +49 7938 81-110 www.ebmpapst.com info1@de.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND NOTES Please read these operating

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl. Cat.-No. capillaries per rotor

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl. Cat.-No. capillaries per rotor CENTRIFUGES BOECO HEMATOCRIT CENTRIFUGE H-240 High-speed bench-top centrifuge for microhematocrit determinations with brushless frequency drive. At 16.060 g sedimentation is completed in just a little

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Technical data sheet. Technical data

Technical data sheet. Technical data echnical data sheet LMQ4A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx 8 m orque 4 Nm Nominal

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet MQ24A-SR Modulating damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 0.8 m² Nominal torque 4 Nm Nominal voltage AC/DC 24 V Control

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3) These instructions provide technical and installation information for the MCC 107 EMC filter series. Only Danfoss qualified personnel is allowed to install this equipment. The personnel must be familiar

More information

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water Kirby NK Heavy Commercial Industrial Unit Cooler Natural fluids: Glycol water MT 20kW LT 16kW 110kW 68kW Product Overview > The NK range is designed for industrial refrigeration, storage or deep-freezing

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost. 811 Compact & ow Price Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.176~ guide... P.781~ General precautions... P.179~ PHOTO PHOTO MEASURE

More information

Juliet - PK. Joystick station. business partner. Features. Design. Materials. Industrial lifting. Construction lifting.

Juliet - PK. Joystick station. business partner. Features. Design. Materials. Industrial lifting. Construction lifting. Juliet - PK Joystick station Juliet-PK joystick stations are control devices for all industrial machinery. They operate as auxiliary controllers of electrical motors through a power interface, such as

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically

More information