DATA LOGGER Series SELECTION GUIDE

Size: px
Start display at page:

Download "DATA LOGGER Series SELECTION GUIDE"

Transcription

1 DATA LOGGER Series SELECTION GUIDE

2 2 Choose from Hioki s extensive line of loggers that s right for your application. HIOKI Logger Search For multichannel measurement and recording Memory HiLogger series LR LR LR LR Page p.3 p.4 p.5 Channels 10 ch 30 (standard); expandable to up to a maximum of 600 Maximum sampling rate 10 ms 10 ms (up to 15 channels) 10 ms Voltage Temperature (Thermocouples) Temperature (Pt 100, JPt100) N/A N/A Humidity N/A Resistance N/A N/A N/A Pulse (4ch) (8ch) *1 (8ch) *1 (8ch) *1 (15ch) *2 Digital N/A (8ch) *1 (8ch) *1 (8ch) *1 (15ch) *2 External Interface USB USB LAN USB LAN External storage USB memory CF card USB memory CF card CF card Battery N/A parameters *1 Pulse + Digital 8ch(Each channel can be set to either pulse or digital.) *2 Digital/Pulse Unit 8996: 15ch Compact solutions for measuring 1 or 2 channels Data Logger series LR5001 LR5011 LR5031 LR5051 LR5040s parameters and channels range LR6(AA) Alkaline battery 1.5V Temperature 1ch and Humidity 1ch 40.0 to 85.0 C 0% to 100%rh Temperature 1ch Instrumentation 1ch AC Current 2 ch DC Voltage 1ch 40.0 to C DC to ma AC 0.00 to 1000 A LR5041: -50 mv to 50 mv LR5042: -5 V to 5 V LR5043: -50 V to 50 V Power and energy loggers For use in environmental, energy, and power supply management (demand monitoring) applications Detailed catalogs also available Clamp on Power Logger PW Use a power logger to implement energy-saving measures!

3 Memory HiLogger series LR ch 3 Featuring USB flash drive support and improved accuracy! Your Personal 10-channel Logger Memory HiLogger LR Voltage Thermocouple Pulse Key Point Lightest weight in its class and Easy Operation Ten Isolated Analog Input Channels 10ms Sampling and Recording Across All Channels Ultra-compact for convenient portability Noise-resistant measurement circuitry for improved readings Improved thermocouple measurement accuracy and reference junction compensation accuracy Real-time recording to a CF card or USB memory stick Real-time recording of up to 10ms/ sample data to USB or CF memory devices (only the Hioki CF card is guaranteed for correct operation) Small and light enough for the palm of your hand - yet completely isolated Monitor in real-time on the PC using bundled Logger Utility freeware General specifications (product guaranteed for one year) Number of channels parameters Max. allowable input Max. rated voltage to earth Recording intervals Selectable Filters Memory capacity External Interfaces Display Functions Dimensions and mass Analog: 10 isolated channels using scanning input method (M3 mm dia. screw terminal block) Pulse: 4 channels (All pulse inputs share common ground with the main unit) [Voltage] ±100 mv to ±60 V, 1-5V f.s., Max. resolution 5μV [Temperature (Thermocouples)] 200 C to 1800 C (depend on the sensor), Thermocouples (K, J, E, T, N, R, S, B), Max. resolution 0.1 C [Temperature (Pt 100 sensor)] not available [Humidity] not available [Totalized pulses] 0 to 1000M pulse (No-voltage a contact, open collector or voltage input), Max. resolution 1 pulse [Rotation count] 0 to 5000/n (r/s) f.s. (No-voltage a contact, open collector or voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000) DC 60 V (Analog input), DC 0 V to 10 V (Pulse input) AC 30 Vrms, DC 60 V (Upper limit voltage that does not cause damage when applied between input channel and chassis, and between each input channels) 10 ms to 1 hour, 19 selections (All input channels are scanned at high speed during every recording interval) 50 Hz, 60 Hz, or OFF (digital filtering of high frequencies on analog channels) Internal storage: 3.5 MWords, External storage: CF card or USB memory stick (only the Hioki CF card is guaranteed for correct operation) USB 2.0 mini-b receptacle 1; Functions: Control from a PC, Transfers files from the installed CF card to a PC (cannot transfer files from the connected USB memory stick to a PC via USB communication), Data copy between CF card and USB memory stick 4.3-inch WQVGA-TFT color LCD ( dots) Save data to the CF Card or USB memory stick in real time, Numerical Calculations, etc. AC Adapter Z1005: 100 to 240 VAC (50/60 Hz), Battery Pack 9780: Continuous use 2.5 hours 12 V DC supply: 10 to 16 V (please contact Hioki distributor for cable; less than 3 m/9.84 ft cable length) 176 mm (6.93 in) W 101 mm (3.98 in) H 41 mm (1.61 in) D, 550 g (19.4 oz) (Battery Pack 9780 not installed) Guide 1, CD-R (Instruction Manual PDF, Logger Utility Instruction Manual PDF, Data acquisition application program Logger Utility) 1, USB cable 1, AC Adapter Z Removable storage (CF card) AC Adapter Z1005 (100 to 240 V AC, Supplied ) Battery Pack 9780 (NiMH, Charges while installed) Soft Case 9812 (Includes space for small items, Neoprene rubber) Carrying Case 9782 (Includes compartment for options, Resin coated) Connection Cable 9641 (For pulse inputs, 1.5 m (4.92 ft) length) PC Card 2G 9830 PC Card 1G 9729 PC Card 512M 9728 PC Card 256M 9727 PC Card Precaution Use only PC Cards sold by Hioki. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.

4 4 Memory HiLogger series LR , LR , LR ch to 60ch Portable Data Logger with 30 Standard Channels, Expandible to 60 Channels Memory HiLogger LR , LR , LR Voltage Thermocouple Pt100/JPt100 Resistance Humidity Pulse Digital Protect valuable data in the event of a power outage or other problem with a portable, multichannel logger Key Point Compact size despite 30-channel standard capabilities Write data to USB memory stick or CF card in real-time Protected against unexpected power outages Digital filtering function for enhanced noise immunity All input channels are isolated and high withstand voltage n Enhanced Noise Immunity High-frequency noise is rejected by means of a digital filter. n High withstand voltage Maximum voltage that can be input between terminals: ±100 V DC LR8400 (with built-in Voltage/Temp Unit LR8500 2) LR8401 (with built-in Universal Unit LR8501 2) LR8402 (with built-in LR8500 1, LR8501 1) General specifications (product guaranteed for one year) Analog input Voltage/ Temp Unit LR8500 Analog input Universal Unit LR8501 Note: Isolated from each channel to chassis *Red text: LR8501 only Pulse, Digital input Recording intervals Digital filter Data storage Interfaces voltage between each channels of Universal Unit: 300 V DC voltage between each channels of Voltage/Temp Unit: 250 V DC [No. of channels] 15 analog channels; isolated scanning method input ([LR8500] 2 terminals: M3 screw type, [LR8501] 4 terminals: push-button type) [Voltage] ±10 mv to ±100 V, 1-5 V f.s., Max. resolution: 500 nv Note: Isolated between channels and from each channel to chassis [Temperature (Thermocouples)] -200 C to 2000 C (depends on the sensor), Thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01 C Note: Isolated between channels and from each channel to chassis [Temperature (Pt 100, JPt 100 sensor)] -200 C to 800 C, Max. resolution 0.01 C Note: Not isolated between channels [Resistance] 0 Ω to 200 Ω f.s., Max. resolution 0.5 mω Note: Not isolated between channels [Humidity] 5.0 to 95.0 % rh (use with the option sensor), resolution 0.1 % rh Note: Not isolated between channels nor from each channel to chassis [Max. rated voltage between isolated input channels] LR8500: 250 V DC, LR8501: 300 V DC [Max. allowable input] ±100 V DC [Max. rated voltage from isolated terminals to ground] 300 V AC, DC [No. of channels] 8 channels, pulse / digital selectable for each channel, M3 screw terminal, not isolated, common ground [Pulse totalization] 0 to 1000 M pulse (No-voltage 'a' contact; normally open, open collector or voltage input), Max. resolution 1 pulse [Pulse revolutions] 0 to 5000 /n (r/s) f.s. (same as Pulse totalization input signal condition), resolution 1/n (r/s) Note: "n" is the number of sensor output pulses per revolution, 1 to 1000 [Digital input] Record logical "1" or "0" at each sampling [Max. rated voltage between input channels] Not isolated [Max. allowable input] 0 to 50 V 10 ms to 50 ms, 100 ms to 1 hour, 19 selections (All input channels are scanned at high speed during every recording interval) Note: limited by using channels at 10 ms to 50 ms interval Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set) Internal memory: 8 M-words, Data storage media: CF card or USB memory (Only data recorded to a genuine Hioki CF card is guaranteed) [LAN] 100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or system Note: LAN communication support planned from software Ver [USB] USB 2.0 High-speed capable, series mini-b receptacle Functions: Data acquisition using bundled software or PC commands, Transfer data from the CF card to a PC via USB drive mode Note: Data transfer not possible from USB memory sticks 5.7 inch TFT color liquid crystal display ( pixel) Save waveform data in real time to the CF card or USB memory stick, Numerical value calculations, Waveform calculations, and others AC Adapter : 100 to 240 V AC (50/60 Hz), Battery Pack Z1000: Continuous use 5 h, External power: 10 to 28 V DC 272 mm (10.71 in) W mm (7.18 in) H 66.5 mm (2.62 in) D, 1.8 kg (63.5 oz), (LR main unit, excluding the Battery Pack 370 g/ 13.1 oz) Display device Functions Dimensions and mass Detailed operating manual 1, guide 1, AC Adapter , USB cable 1, CD-R (data collection software "Logger Utility") 1 Voltage/Temp Unit LR8500 (2 terminals M-3 mm screw type, 15 channels Voltage, Temperature with thermocouple, or Humidity measurement) Universal Unit LR8501 (4 terminals push-button type, 15 channels Voltage, Temperature with thermocouple, Platinum Resistance temperature sensor, Humidity, or Resistance measurement) Humidity Sensor Z2000 (3 m (9.84 ft) length) Battery Pack Z1000 (NiMH, Charges while installed) AC Adapter (100 to 240 V AC, Bundled with the LR8400, LR8401 and LR8402) LAN Cable 9642 (Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length) Carrying Case C1000 (Includes compartment for options) Fixed Stand Z5000 (For wall hanging and slanted bench mounting) Maximum rated voltage to earth: 300 V AC/DC Removable storage (CF card) PC Card 2G 9830 PC Card 1G 9729 PC Card 512M 9728 PC Card 256M 9727 PC Card Precaution Use only PC Cards sold by Hioki. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.

5 Memory HiLogger series ch to 600ch 5 Up to 600 Channels of Data Logging Memory HiLogger 8423 Voltage Thermocouple Pt100/JPt100 Humidity Pulse Digital Key Point Mix and match input units to build a measurement system with up to 600 channels. More robust isolation: 600 V terminal-to-ground, 200 V/120 V channel-to-channel Capture data with 15 to a maximum of 600 channels USB 2.0, LAN 100BASE-TX, Store to 1GB PC Card Dual sampling to make efficient use of available memory n Enhanced Noise Immunity Memory HiLogger 8423 Maximum number of connectable units: 8 Voltage/Temp Unit channles, Voltage, Thermocouple input Enhanced noise immunity reduces the impact of switching noise from inverterequipped devices and 50/60 Hz hum noise. Universal Unit channels, Voltage, Thermocouple, Resistance temperature sensor, Humidity measurement Digital/Pulse Unit channels, ON/OFF logic signal, Totalized pulses (integrated or instantaneous), Rotation count Alarm Unit channels, Open-collector output General specifications (product guaranteed for one year) n High withstand voltage voltage to earth: 600V AC, DC voltage to earth between each module: 600V AC, DC voltage between each channel: 200V DC 200V in model V in model 8949 No. of connectable units parameters Model 8948 parameters Model 8949 parameters Model 8996 Recording intervals Functions Maximum 8 units (total 120 channels), Bundle 8 Modules together to achieve a 120-channel System, Bundle 5 Systems together to enable a maximum of 600 channels of simultaneous recording [Voltage] ±150mV to ±100V, 1-5V f.s., Max. resolution 5µV, Max. allowable input : DC 100V, Max. rated voltage between channels : 200 V DC, Max. rated voltage to earth : 600 V DC, AC [Temperature (Thermocouples)]: -200 C to 2000 C (depend on the sensor), Thermocouples(K, E, J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01 C [Voltage] ±150mV to ±60V, 1-5V f.s., Max. resolution 5µV, Max. allowable input : DC 60V, Max. rated voltage between channels : 120 V DC, Max. rated voltage to earth : 600 V DC, AC [Temperature (Thermocouples)] -200 C to 2000 C (depend on the sensor), Thermocouples(K, E, J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01 C [Temperature (Pt 100, JPt 100 sensor)] -200 C to 800 C, Max. resolution 0.01 C [Humidity] 5.0 to 95.0% rh (use with the option sensor), 0.1% rh resolution [Totalized pulses] 0 to 1000M pulse, Max. resolution 1 pulse [Rotation count] 0 to 5000/n (r/s) f.s., Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000) [Digital input] ON/OFF digital signal [Max. allowable input] DC 50V, Max. rated voltage between channels : 33V AC, 70V DC, Max. rated voltage to earth : 600 V DC, AC, (Upper limit voltage that does not cause damage when applied between CH-1 to CH-5 each channel and chassis, CH-6 to CH-10 each channel and chassis, CH-11 to CH-15 each channel and chassis, and between each UNITs), (common ground for CH-1 to CH-5, common ground for CH-6 to CH-10, common ground for CH-11 to CH-15) 10ms to 1hr, 19 range (5s to 1hr when combined with humidity measurement), Dual sampling : Recording intervals can be specified for every input module (high-speed and low-speed) data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the Alarm Unit 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function [LAN] supports 100Base-TX, [USB] Ver 2.0, mini-b receptacle, CF card slot AC Adapter : 20 VA (when connected with 8 units), External power: 9.6 to 15.6 V DC, Please contact Hioki for connection cord Interfaces Dimensions and mass 67 mm (2.64 in) W 133 mm (5.24 in) H 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only) Operating Manual 1, Quick Start Manual 1, AC Adapter , USB cable 1, Connection Plate 1, CD-R (data collection software "Logger Utility") 1, Connector cover 1, Ferrite clamp 1 AC Adapter (Supplied as standard, 100 to 240 V AC, Supplied ) LAN Cable 9642 (Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length) Connection Cable 9683 (For synchronization, cable length 1.5m (4.92ft)) Humidity Sensor 9701 (1-channel, for UNIVERSAL UNIT 8949) Removable storage (CF card) PC Card 1G 9729 PC Card 512M 9728 PC Card 256M 9727 PC Card Precaution Use only PC Cards sold by Hioki. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.

6 6 Data Logger series LR5000 Series Temperature Humidity Record Temperature and Humidity Simultaneously Humidity Logger LR5001 items Temperature 1ch and Humidity 1ch range [Temperature] -40 C to 85 C [Humidity] 0% to 100%rh Accuracy See figure at lower right. Waterproof and IP54 (splash-proof construction) (with sensor connected, excluding sensor tip) dustproof -20 C(-4 F) to 70 C(158 F), 80%rh or less (non-condensating) LR6 (AA) Alkaline battery 1.5V 1 Case 1 : Approx. 3 months Case 2: Approx. 20 days Dimensions and mass Approx. 79mm(3.11in)W 57mm(2.24in) H 28mm(1.10in)D, 105g(3.7oz) Humidity Sensor LR9504 1, Kickstand, LR6 (AA) Alkaline battery 1.5V 1, Instruction manual 1, Operation manual 1 Temperature range : C to 85.0 C (-40 F to 185 F) Humidity range : 0.0%rh to 100.0%rh Response time : Approx. 300 seconds (Temperature ; 90% response time) Waterproofness: None Sensor head size : 13mm 30mm (0.51in 1.18in) Humidity Sensor LR9501 (1m) Humidity Sensor LR9502 (5m) Humidity Sensor LR9503 (10m) Humidity Sensor LR9504 (40mm) n Humidity (LR5001+Sensor) * ±10 %rh ±10 %rh ±8 %rh 70 Relative humidity : %rh ±10 %rh ±15 %rh ±8 %rh* ±8 %rh ±6 %rh ±8 %rh * 50 ±6 * %rh ±6 %rh ±5 %rh ±6 %rh Temperature : C *Values provided for reference only. n Temperature (LR5001+Sensor) C up to (not including) 0.0 C ±1.0 C 0.0 C up to (not including) 35.0 C ±0.5 C 35.0 C up to (not including) 70.0 C ±1.0 C 70.0 C to 85.0 C ±2.0 C Measure Temperature with External Sensor Temperature Logger LR5011 items Temperature 1ch range C to 180 C Note: Depends on measurement range of sensor C up to (not including) 0.0 C: ±1.0 / 0.0 C up to (not including) 35.0 C: ±0.5 / Accuracy 35.0 C up to (not including) 70.0 C: ±1.0 / 70.0 C up to (not including) C: ±2.0 / C to C: ±5.0 Waterproof and IP54 (splash-proof construction) (with sensor connected, excluding sensor tip) dustproof -20 C(-4 F) to 70 C(158 F), 80%rh or less (non-condensating) LR6 (AA) Alkaline battery 1.5V 1 Case 1 : Approx. 2 years Case 2: Approx. 2 months Dimensions and mass Approx. 79mm(3.11in)W 57mm(2.24in) H 28mm(1.10in)D, 105g(3.7oz) LR6 (AA) Alkaline battery 1.5V 1,Kickstand, Instruction manual 1, Operation manual 1 Molded plastic type Temperature range: -40 C to 180 C (-40 F to 356 F) Response time : Approx. 100 seconds (90% response time) Waterproofness : Watertight JIS C 0920 (when attached to logger) Sensor head size: Ø6mm 28mm (0.24in 1.10in) Lug type Temperature range: -30 C to 180 C (-22 F to 356 F) Response time : Approx. 45 seconds (90% response time) Waterproofness : Watertight JIS C 0920 (when attached to logger) Diameter: Outer: 7mm (0.26in) Inner: 3.2mm (0.13in) Sheathed type Temperature range: -40 C to 120 C (-40 F to 248 F) Response time : Approx. 90 seconds (90% response time) Waterproofness : Watertight JIS C 0920 (when attached to logger) Sensor head size: Ø4mm 180mm (0.16in 7.09in) Needle type Temperature range: -40 C to 120 C (-40 F to 248 F) Response time : Approx. 20 seconds (90% response time) Waterproofness : Watertight JIS C 0920 (when attached to logger) Sensor head size: Ø1.3mm 25mm (0.05in 0.98in) Temperature Sensor LR9601 (1m) Temperature Sensor LR9602 (5m) Temperature Sensor LR9603 (10m) Temperature Sensor LR9604 (45mm) Temperature Sensor LR9611 (1m) Temperature Sensor LR9612 (5m) Temperature Sensor LR9613 (10m) Temperature Sensor LR9621(1m) Temperature Sensor LR9631 (1m)

7 Data Logger series LR5000 Series Instrumentation DC Voltage AC Current 7 Record 4-20 ma Instrumentation Signals, etc. Instrumentation Logger LR5031 items For instrumentation / 0 to 20mA DC, 1ch range DC to 30.00mA Basic Accuracy ±0.5%rdg. ±5dgt. (@23 C±5 C) Waterproof and IP54 (splash-proof construction) (with sensor connected, excluding sensor tip) dustproof -20 C(-4 F) to 70 C(158 F), 80%rh or less (non-condensating) LR6 (AA) Alkaline battery 1.5V 1 Case 1 : Approx. 2 years Case 2: Approx. 2 months Dimensions and mass Approx. 79mm(3.11in)W 57mm(2.24in) H 28mm(1.10in)D, 105g(3.7oz) Connection Cable LR9801 1, Kickstand LR6 (AA) Alkaline battery 1.5V 1, Instruction manual 1, Operation manual 1 Record Instrumentation Signals and Measure Analog Output from Sensors and other Devices Voltage Logger LR5041, LR5042, LR5043 LR5041 LR5042 LR5042 items DC voltage 1ch range mV to 50.00mV V to 5.000V V to 50.00V Basic Accuracy ±0.5%rdg. ±5dgt. (@23 C±5 C) Waterproof and dustproof IP54 (splash-proof construction) (with sensor connected, excluding sensor tip) -20 C(-4 F) to 70 C(158 F), 80%rh or less (non-condensating) LR6 (AA) Alkaline battery 1.5V 1 Case 1 : Approx. 2 years Case 2: Approx. 2 months Dimensions and mass Approx. 79mm(3.11in)W 57mm(2.24in) H 28mm(1.10in)D, 105g(3.7oz) Connection Cable LR9802 1, Kickstand LR6 (AA) Alkaline battery 1.5V 1, Instruction manual 1, Operation manual 1 Easily Record Load Current of 50Hz/60Hz lines and Leak Current Clamp Logger LR5051 items AC Current (2 channels) When Using 9669 :1000A range When Using CT6500 :50.00A/ 500.0A range range When Using :5.000A/ 50.00A range When Using 9675 :500.0mA/ 5.000A range When Using :500.0mA/ 5.000A range Basic Accuracy ±0.5%rdg. ±5dgt.+Clamp sensor accuracy -0 C(32 F) to 50 C(122 F), 80%rh or less (non-condensating) LR6 (AA) Alkaline battery 1.5V 2 Case 1 : Approx. 1 years Case 2: Approx. 1 months Dimensions and mass Approx. 79mm(3.11in)W 70mm(2.76in) H 37mm(1.46in)D, 165g(5.8oz) LR6 (AA) Alkaline battery 1.5V 2 Instruction manual 1, Operation manual 1 Clamp on Sensor Connection Cable 9219 required (sold separately) Clamp on Leak Sensor Measurable conductor diameter 9669 CT Ø55mm(2.17") or less, 80(3.15") 20(0.79") mm busbar Ø46mm(1.81") or less Ø15mm(0.59") or less Ø30mm(1.18") Ø40mm(1.57") Primary current rating 1000A AC 500A AC 50A AC 10A AC 10A AC LR5051 range(s) 1000A 50.00/500.0A 5.000/50.00A 500.0mA/5.000A 500.0mA/5.000A Accuracy(45Hz to 66Hz) ±1.0%rdg. ±0.01%rdg. ±1.5%rdg. ±0.03%rdg. ±0.3%rdg. ±0.02%rdg. ±1.0%rdg. ±0.005%rdg. ±1.0%rdg. ±0.05%rdg. voltage to earth 600Vrms 600Vrms 300Vrms 300Vrms 300Vrms

8 Data Logger series LR5000 Series Shared specifications and options LR5000 Series common specifications (product guaranteed for one year) Recording interval 1/ 2/ 5/ 10/ 15/ 20/ 30 seconds, 1/ 2/ 5/ 10/ 15/ 20/ 30/ 60 minutes Recording methods Recording modes Storage capacity Display items Recording start/ stop Data backup Interfaces [One time recording] Stop recording when the memory capacity is full. [Endless recording] Continue recording even when the memory capacity is full. (Old data is overwritten.) [Instantaneous recording] Instantaneous values are recorded at every recording interval. [Statistical value recording] Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval. [Instantaneous value mode] 60,000 data sets per channel [Statistical value mode] 15,000 data sets per channel Measured value, Interval configration, Date, Time, Alarm, Remaining battery power, Number of data, Maximum data, Minimum data [Recording start] Manual start, Timer start [Recording stop] Manual stop, Timer stop, When the memory capacity is full (One time recording) Data from the last recording session is always backed up. Infrared optical communications with LR5091, LR During battery replacement, recording and clock operations are preserved for about 30 seconds. (Recording operation continues if the battery is replaced within about 30 seconds.) Note: With the LR5001, recording is interrupted during battery replacement if the battery is very weak. After batteries are replaced, recording resumes automatically. Previously recorded data is not lost during battery replacement. LR5000 Series common options Magnetic Strap Z5004 Can be positioned at an angle with the included stand. (included, except for Model LR5051) Wall-mounted Holder LR9901 *Not compatible with Model LR5051 Transfer data from Data Logger to PC Communication Adapter LR5091 Data Collector LR Communication Adapter LR5091 USB Connect the Data Collector to a computer after downloading the measurement data to its internal memory. USB HEADQUARTERS: 81 Koizumi, Ueda, Nagano, , Japan TEL FAX / os-com@hioki.co.jp HIOKI USA CORPORATION: TEL FAX / hioki@hiokiusa.com Data collection method Connect the Communication Adapter to a computer and then place a datamini in the cradle. Data Collector LR Bring the Data Collector to the measurement site and collect data. Download the measurement data onto an SD card and then insert the card into a computer. LR5091 specifications HIOKI (Shanghai) SALES & TRADING CO., LTD.: TEL FAX / info@hioki.com.cn HIOKI INDIA PRIVATE LIMITED: TEL FAX hioki@hioki.in HIOKI SINGAPORE PTE. LTD.: TEL FAX info@hioki.com.sg Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI KOREA CO., LTD.: TEL FAX info-kr@hioki.co.jp Transfer data from a Data logger to a PC Features Transfer Data Logger configurations or clock settings from a PC to the Data Logger Interface with Data Logger Infrared optical communications Interface with PC USB2.0, Full Speed, Series Mini B Receptacle Operating environment Indoors DC5V (USB bus power) power 0.5VA 0 C(32 F) to 40 C(104 F), 80%rh or less (non-condensating) Dimensions, Mass Approx. 83mm(3.27 in)w 61mm(2.40in)H 19mm(0.75in)D, 43g(1.5oz) USB cable (1m) 1, CD (Application software "LR5000 Utility") 1 LR specifications Collect recorded data from the Data Logger to internal memory or SD memory card View collected data in a graph Transfer Data Logger configurations or clock settings from internal Features memory or SD memory card to the Data Logger Transfer data from a Data Logger to a PC Transfer Data Logger configurations or clock settings from a PC to the Data Logger Interface with Data Logger Infrared optical communications Interface with PC USB2.0, Full Speed, Series Mini B Receptacle Clock functions Auto calender, auto leap year Display Dot-matrix LCD ( dots) Data Logger configurations (Interval, Start/Stop method, Recording mode, Display items Scaling, Alarm, Power-saving mode, Clock, Range) Collected data (Record list, Maximum data, Minimum data, Average, Graph, Value) Internal memory [Instantaneous value mode] 60,000 data elements 16ch capacity of data [Statistical value mode] 15,000 data elements 16ch Removable storage media SD memory card, Save data and configurations Operating environment Indoors DC3V (LR6 (AA) Alkaline battery 1.5V 2) or DC5V (USB bus power) power 1VA Approx. 12 hours or 500 times of data collection 0 C(32 F) to 40 C(104 F), 80%rh or less (non-condensating) Dimensions, Mass 91mm(3.58in)W 141mm(5.55in)H 31mm(1.22in)D, 215g(7.6oz) (excluding batteries) Instruction manual 1, Operation manual 1, LR6 (AA) Alkaline battery 1.5V 2, USB cable(1m) 1, CD (Application software "LR5000 Utility") 1 DISTRIBUTED BY Analyze data with the included software application All information correct as of May. 21, All specifications are subject to change without notice. Series_LoggersE1-35E Printed in Japan

DATA LOGGER Series SELECTION GUIDE

DATA LOGGER Series SELECTION GUIDE DATA LOGGER Series SELECTION GUIDE 2 Choose from Hioki s extensive line of loggers that s right for your application HIOKI Logger For multichannel measurement and recording LR831-20 Page Memory HiLogger

More information

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory. LR5000 Series DATA LOGGER. Data Loggers

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory. LR5000 Series DATA LOGGER. Data Loggers 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com DATA LOGGER LR5000 Series Data Loggers Complete Line of Easy-to-Use Compact Loggers

More information

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory. LR5000 Series DATA LOGGER. Data Loggers

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory. LR5000 Series DATA LOGGER. Data Loggers DATA LOGGER LR5000 Series Data Loggers Complete Line of Easy-to-Use Compact Loggers with Expanded Memory The new HIOKI compact logger series easily records temperature, voltage, current, and instrumentation

More information

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory. DATA LOGGER LR5000 Series

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory. DATA LOGGER LR5000 Series DATA LOGGER LR5000 Series Complete Line of Easy-to-Use Compact Loggers with Expanded Memory The new HIOKI compact logger series easily records temperature, voltage, current, and instrumentation signals

More information

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515, LR8520 For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection Please see www.hioki.com

More information

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy MEMORY HiLOGGER LR8431-20 MEMORY HiLOGGER 8430 Data Loggers Featuring USB flash drive support and improved accuracy Your Personal 10-channel Logger Real-time recording of up to 10ms/ sample data to USB

More information

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy MEMORY HiLOGGER LR8431 Featuring USB flash drive support and improved accuracy Your Personal 10-channel Logger Real-time recording of up to 10ms/ sample data to USB or CF memory devices Small and light

More information

8420/8421/ MEMORY HiLOGGER

8420/8421/ MEMORY HiLOGGER Data Loggers 2003 8420/8421/8422-01 A Complete Line-up of 8 to 32 Channel Models LAN Compatibility plus Simultaneous Display of Graphics and Data As demand for multiple-channel temperature recording for

More information

, , MEMORY HiLOGGER

, , MEMORY HiLOGGER 8420-51, 8421-51, 8422-51MEMORY HiLOGGER Data Loggers Internal memory capacity is greatly increased four times that of previous models! New multi-channel loggers with enhanced noise immunity As demand

More information

Rugged, Professional and Ready for the Field MR MEMORY HiCORDER. Capture high- to low-voltage signals in a single device

Rugged, Professional and Ready for the Field MR MEMORY HiCORDER. Capture high- to low-voltage signals in a single device MEMORY HiCORDER MR8880-20 Recorders Capture high- to low-voltage signals in a single device Rugged, Professional and Ready for the Field CAT III 600 V insulation performance Maximum 600V AC/DC input -

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

The Most Comprehensive Portable PQA on The Market

The Most Comprehensive Portable PQA on The Market Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) POWER QUALITY ANALYZER 3197 Power Measuring Instruments The Most Comprehensive Portable PQA on The Market Catch Power

More information

LEAK CURRENT HiTESTER. Fully Supporting IEC rd Edition and JIS T0601-1:2012 Standards (ST5540 only)

LEAK CURRENT HiTESTER. Fully Supporting IEC rd Edition and JIS T0601-1:2012 Standards (ST5540 only) LEAK CURRENT HiTESTER ST5540/ST5541 Safety standards measuring instruments Fully Supporting IEC 60601-1 3rd Edition and JIS T0601-1:2012 Standards (ST5540 only) Leak Current Measurement - Essential to

More information

MEMORY HiCORDER. Palm-size but Powerful Easy recording anytime, anywhere! Recorders

MEMORY HiCORDER. Palm-size but Powerful Easy recording anytime, anywhere! Recorders MEMORY HiCORDER 8870-20 Recorders Palm-size but Powerful Easy recording anytime, anywhere! Hioki's traditional MEMORY HiCORDER functions are now condensed into a lowprofile, turn-key device. The compact

More information

Saved Data playback Saved data in Memory card can be easily called out and played back on display

Saved Data playback Saved data in Memory card can be easily called out and played back on display Paperless Recorder Type:PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played

More information

midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division

midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division 1. 2 models which are Multi-input and Withstand-voltage in the line-up. Basic Function: All Channel isolated

More information

BT3563/BT3562/3561. BATTERY HiTESTER

BT3563/BT3562/3561. BATTERY HiTESTER BATTERY HiTESTER BT3563/BT3562/3561 Components measuring instruments Simultaneous high-speed measurement of internal resistance and battery voltage From large-cell to high-voltage battery testing - HIOKI

More information

Ideal for temperature measurement, monitoring and management of temperature data records. Thermometers

Ideal for temperature measurement, monitoring and management of temperature data records. Thermometers Ideal for temperature measurement, monitoring and management of temperature data records Thermometers The TM Series offers excellent data management functions Collect up to 5000 data items with time-stamp,

More information

8 or 16 Channel Universal Input Touch Screen Data Logger

8 or 16 Channel Universal Input Touch Screen Data Logger 8 or 16 niversal Input Touch Screen Data Logger OM-DAQXL Stylus (included). OM-DAQXL shown smaller than actual size. 7" Touch Screen TFT Display 8 or 16 Analog Inputs 8 or 16 Virtual (Math) s 8 Digital

More information

midi LOGGER GL840 Quick Start Guide GL840-UM-850

midi LOGGER GL840 Quick Start Guide GL840-UM-850 midi LOGGER GL840 Quick Start Guide 604849020 GL840-UM-850 Thank you for choose the midi LOGGER GL840. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL820 midi Logger Built-in 5.7" TFT LCD Color Display Stand-alone or PCconnected operation 20 Analog Channels Standard, Expandable to 200 Input-to-output and channel-to-channel Isolation USB and Ethernet

More information

Leak Current Measurement - Essential to Electrical Safety. Compliance with IEC :2005 Ed 3.0, JIS T :2012

Leak Current Measurement - Essential to Electrical Safety. Compliance with IEC :2005 Ed 3.0, JIS T :2012 LEAK CURRENT HiTESTER ST5540, ST5541 Leak Current Measurement - Essential to Electrical Safety Uninterrupted polarity switching function dramatically reduces cycle time Support for rated currents up to

More information

BT3563/BT3562/3561. BATTERY HiTESTER

BT3563/BT3562/3561. BATTERY HiTESTER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BATTERY HiTESTER BT3563/BT3562/3561 Component measuring instruments Simultaneous

More information

Setting New Heights in Data Recording

Setting New Heights in Data Recording Isolated/Universal Input, Standalone Multi-Channel Datalogger GL840-M / GL840-WV / Setting New Heights in Data Recording Flexible input system for wide array of applications Wireless LAN capability for

More information

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL220 midi Logger Built-in 4.3" WQVGA TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor

More information

RESISTANCE METER RM3544, RM3548

RESISTANCE METER RM3544, RM3548 RESISTANCE METER RM3544, RM3548 Component measuring instruments Easy to use with high-accuracy Resistance Meters for Production Lines and MRO The Resistance Meters RM3544/RM3544-01/RM3548 can measure the

More information

XL112, XL114 ポータブルデータロガ

XL112, XL114 ポータブルデータロガ User's Manual Introduction Thank you for purchasing our XL100 Portable Data Station/Portable Data Logger. This Quick Setup Manual briefly describes the key operations as well as setting examples of the

More information

8 or 16 Channel Universal Input Touch Screen Data Logger

8 or 16 Channel Universal Input Touch Screen Data Logger 8 or 16 niversal Input Touch Screen Data Logger OM-DAQXL TM OM-DAQXL shown smaller than actual size. 7" Touch Screen TFT Display 8 or 16 Analog Inputs 8 Digital I/O (4 Inputs, 4 Outputs) IIoT-Ready Through

More information

Fungal Growth Rate at a Glance

Fungal Growth Rate at a Glance WIRELESS FUNGAL LOGGER LR8520 Data Loggers Fungal Growth Rate at a Glance Predict the start of fungal growth Prevent Fungal Occurrence in Business Critical Locations Food & Grain Storage Document Storage

More information

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES Single-channel isolated signal-conditioning modules. Accepts outputs from Thermocouple, millivolt, volt and current signals. Complete microcomputer-based

More information

Models PEL 102 & PEL 103

Models PEL 102 & PEL 103 V1 V2 V3 N 1000V CAT III I1 I2 I3 600V CAT IV POWER & ENERGY LOGGER ON/OFF START/STOP Special product features MEASURES '''' ''' D E M A N D $ TRACKS E N E R G Y C O S T POWER QUALITY ANALYZERS, METERS

More information

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software

More information

Datum-Y Portable Data Station (XL100)

Datum-Y Portable Data Station (XL100) Specification Sheet Datum-Y Portable Data Station (XL100) CAUTION: Underlined Specification that is indicated by will be included by December 26, 2005. We will prepare upgrade file to version up your having

More information

PIECAL 510B/511B RTD Simulator Operating Instructions

PIECAL 510B/511B RTD Simulator Operating Instructions PIECAL 510B/511B RTD Simulator Operating Instructions (Shown without optional boot) (Shown with optional boot) Product Description Easy to use With the PIECAL 510B/511B you can check & calibrate all your

More information

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851 midi LOGGER HV GL2000 Quick Start Guide 604929220 GL2000-UM-851 Thank you for choose the midi LOGGER HV GL2000. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in

More information

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver Type: PHU Long Term Record Data Saving years in Compact Flash (In case of using 5MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display Math

More information

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

IP 20. Rated. with terminals

IP 20. Rated. with terminals PROGRAMMABLE Special product features D ATA POWER fr o m 32MB S T O R A G E U S B DATA LOGGERS Two-Channel DC Voltage, Current, Pulse & Event Model L452 Bluetooth-enabled logger and event counter that

More information

Model PEL 102. POWER QUALITY ANALYZERS, METERS & LOGGERS Power & Energy Loggers PEL 100 Series

Model PEL 102. POWER QUALITY ANALYZERS, METERS & LOGGERS Power & Energy Loggers PEL 100 Series V1 V2 V3 N I1 I2 I3 1000V CAT III 600V CAT IV POWER & ENERGY LOGGER ON/OFF START/STOP Special product features MEASURES '''' ''' D E M A N D $ TRACKS E N E R G Y C O S T POWER QUALITY ANALYZERS, METERS

More information

3156 LEAK CURRENT HiTESTER

3156 LEAK CURRENT HiTESTER 2003 3156 LEAK CURRENT HiTESTER Safety Standards Measuring Instruments The Long-Awaited Bench-type Model Is Here! Leakage Current Measurement Essential for Electrical Safety Because of the risks it poses,

More information

Easy to use with high-accuracy Resistance Meters for Production Lines and MRO RESISTANCE METER RM3544, RM3548

Easy to use with high-accuracy Resistance Meters for Production Lines and MRO RESISTANCE METER RM3544, RM3548 RESISTANCE METER RM3544, RM3548 Easy to use with high-accuracy Resistance Meters for Production Lines and MRO The Resistance Meters RM3544/RM3544-01/RM3548 can measure the winding resistance of devices

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

Measure Sounds Reliably

Measure Sounds Reliably Measure Sounds Reliably Sound Level Meter Class1 NL-52 Sound Level Meter Class2 NL-42 Extremely User Friendly Rion s NL-52 and NL-42 sound level meters provide full support for the process. The NL-52 and

More information

Ultra-Accurate Temperature Measurement Instruments

Ultra-Accurate Temperature Measurement Instruments TEMPpoint Temperature Measurement Instruments Ultra-Accurate Temperature Measurement Instruments TEMPpoint is a series of precision temperature measurement instruments designed for high accuracy and industrial

More information

MEMORY HiCORDER. Palm-size but Powerful Easy recording anytime, anywhere! Recorders

MEMORY HiCORDER. Palm-size but Powerful Easy recording anytime, anywhere! Recorders MEMORY HiCORDER 8870-20 Recorders Palm-size but Powerful Easy recording anytime, anywhere! Hioki's traditional MEMORY HiCORDER functions are now condensed into a lowprofile, turn-key device. The compact

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-852

midi LOGGER GL240 Quick Start Guide GL240-UM-852 midi LOGGER GL240 Quick Start Guide 604249022 GL240-UM-852 Thank you for choosing Graphtec midi LOGGER GL240. The Quick Start Guide is to assist with the basic operations. Please refer to the USER'S MANUAL

More information

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) Here is a Hand-Held Data Logger that Really Performs! 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://instserv.com Temperature monitoring has long been recognized

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

Easy recording anytime, anywhere! MEMORY HiCORDER. Palm-size but Powerful. Recorders

Easy recording anytime, anywhere! MEMORY HiCORDER. Palm-size but Powerful. Recorders MEMORY HiCORDER 8870-20 Recorders Palm-size but Powerful Easy recording anytime, anywhere! Hioki's traditional MEMORY HiCORDER functions are now condensed into a lowprofile, turn-key device. The compact

More information

Weighing Indicator. Features. Description. Applications

Weighing Indicator. Features. Description. Applications Force Pressure Temperature Switch Weighing Indicator Description The compact Indicator of model E1932X is a precision and cost effective product for weighing applications. They are ideal for use in mobile

More information

Models PEL 102 & PEL 103

Models PEL 102 & PEL 103 V1 V2 V3 N I1 I2 I3 1000V CAT III 600V CAT IV POWER & ENERGY LOGGER ON/OFF START/STOP Special product features MEASURES '''' ''' D E M A N D $ TRACKS E N E R G Y C O S T POWER QUALITY ANALYZERS, METERS

More information

ARF100 Paperless Recorder

ARF100 Paperless Recorder No. CP-SS-1846E ARF100 Paperless Recorder The ARF100 Paperless Recorder features a highly visible 5.6-inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

Expanding the Basic GL7000 Configuration

Expanding the Basic GL7000 Configuration Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Expanding the Basic GL7000 Configuration The GL7000 is a modular system that allows you to add analog

More information

N EW. Data Logger. 2 GB Internal Memory. ZR-RX Series 32. Easy data recording with all the capacity you need. Best-In-Class.

N EW. Data Logger. 2 GB Internal Memory. ZR-RX Series 32. Easy data recording with all the capacity you need. Best-In-Class. External Dimensions (Unit: mm) ZR-RX70 N EW ZR-RX45 Data Logger 3 ZR-RX Series 3 0 4.6 3.5 48 3 75 5 ZR-RX70 Mounting Screw Holes -M4 Depth 6 ZR-RX45 Mounting Screw Holes -M4 Depth 6 Easy data recording

More information

USB-5100 Series Multi-Channel Data Loggers

USB-5100 Series Multi-Channel Data Loggers Multi-Channel Data Loggers Features Stand-alone, remote multi-channel data loggers The USB-5104 is a high-accuracy, four-channel thermocouple data logger that records temperature in indoor environments

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW WebDAQ 316 Internet Enabled Thermocouple Logger Remote Configuration and Monitoring Virtually Unlimited Storage Integrated HW and SW Flexible Triggers, Alarms, Emails, and SMS Texts Built-in Web Server,

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

PowerPad III Model 8435

PowerPad III Model 8435 Special product features POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer 2GB MEMORY '''' PowerPad III Model CAPT TREND RECORDING RE TRANSIENTS SD card memory capacity for trend

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement for basic use Description is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field

More information

PIECAL 520B & 521B Thermocouple Source Operating Instructions

PIECAL 520B & 521B Thermocouple Source Operating Instructions PIECAL 520B & 521B Thermocouple Source Operating Instructions (Shown without optional boot) Product Description (Shown with optional boot) Easy to use With the PIECAL 520B/521B you can check & calibrate

More information

PCPR01 Paperless Recorder

PCPR01 Paperless Recorder PCPR01 Paperless Recorder Up to 18 channels of universal input UP to 4 Alarm Output Relays With 150mA Power distribution output Communication type: RS485, Modbus RTU With a USB data transfer interface

More information

Integrating Sound Level Meter. LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2)

Integrating Sound Level Meter. LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2) Integrating Sound Level Meter LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2) Focusing on field measurement with versatile functions, New LA LA-1400 / 4400 series integrating sound level meters

More information

Current clamps in a range of sizes (small to large diameter) for a variety of applications

Current clamps in a range of sizes (small to large diameter) for a variety of applications Clamp-on Power Meters User-friendly features in a compact body. NEW Energy conservation tool Small size for installation in cubicles and inside distribution panels Size: 117 161 51 mm (W H D) Weight: Approximately

More information

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

Web-enabled DAQ System

Web-enabled DAQ System 2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing

More information

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC The midi LOGGER GL200 has evolved 10 channels compact data logger No only for temperature but also for voltage fluctuation measurement

More information

Temperature Measurement

Temperature Measurement Copyright 1999-2002. All rights reserved. Web design by Sullivan Creative -1000 to +3500 and -10000 to +35000 Count Thermocouple, RTD, and Thermistor Temperature Measurement in C or F without Recalibration

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-850

midi LOGGER GL240 Quick Start Guide GL240-UM-850 midi LOGGER GL240 Quick Start Guide 604249020 GL240-UM-850 Thank you for choose the midi LOGGER GL240. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800) Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software

More information

TDS-630. High Performance Easy Handling

TDS-630. High Performance Easy Handling TDS-630 High Performance Easy Handling High Speed and High Functionality achieved by enhancing Measurement Speed and Processing Function Repeated Measurements in 0.1 seconds per 1000 channels TML-LINK

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

Programmable Switching DC Power Supply

Programmable Switching DC Power Supply SS-C series (300W~900W,, with RS-232 interface) Introduction SS-C series are high accuracy programmable DC power supply with single output. MPU control, RS-232/RS- 485/USB interface for PC control, the

More information

Integrating Sound Level Meters LA-5570/5560/2560

Integrating Sound Level Meters LA-5570/5560/2560 Integrating Sound Level Meters LA-5570/5560/2560 High-functionality Integrating Sound Level Meters Type 1 Sound Level Meters High sensitivity Wide band LA-5570/5560 High-functionality Sound Level Meter

More information

Multi-Function Ground Resistance Tester Model 6471

Multi-Function Ground Resistance Tester Model 6471 Multi-Function Ground Resistance Tester Model 6471 AC Current Probes Model SR182 The Ground Resistance Tester Model 6471 is a portable measurement instrument designed to measure Ground Resistance with

More information

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual LOGGER S0841 Dual channel temperature logger with two binary inputs and LCD display Instruction Manual Instruction Manual for use of S0841 logger Instrument is designed for measurement and record of temperature

More information

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System 3-51 EDX-10 Series Compact Recording System Compact & lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls

More information

ARF200. Paperless Recorder Advanced Recorder

ARF200. Paperless Recorder Advanced Recorder No. CP-SS-1871E ARF200 Paperless Recorder Advanced Recorder Overview The ARF200 Paperless Recorder adopts a highly visible 12.1-inch TFT color LCD, incorporates advanced functions, is easy to use, and

More information

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System 3-49 EDX-10 Series Compact Recording System Compact, lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls

More information

Touch Operator Interface GP4000SERIES.

Touch Operator Interface GP4000SERIES. Touch Operator Interface GP4000SERIES www.proface.com GP4000 SERIES L i n e up Standard Model 12.1" 10.4" Color variation Color variation 7.5" AC 100-240V DC 24V AC 100-240V DC 24V DC 24V DC 24V DC 24V

More information

Precision Hand-held Thermometer

Precision Hand-held Thermometer Precision Hand-held Thermometer measuring monitoring analysing Measuring range from -220 C... +1768 C Measuring accuracy starting with ±0.03% MV Large selection of temperature probes PT 100 or thermocouple

More information

Measurement Systems Datascan Installation and User Guide

Measurement Systems Datascan Installation and User Guide Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog

More information

Multi-functional precision thermometer CTR3000

Multi-functional precision thermometer CTR3000 Calibration technology Multi-functional precision thermometer CTR3000 WIKA data sheet CT 60.15 Applications Pharmaceutical industry Industry (laboratory, workshop and production) Temperature sensor and

More information

Programmable DC power supplies

Programmable DC power supplies 3-Year Warranty Series 2260B 360W, 720W, and 1080W versions with voltages up to 800V and currents up to 108A Programmable voltage or current rise and fall times prevents damage to low impedance loads from

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

TEST & MEASUREMENT NEW NEW NEW FULL RANGE OF TEST & MEASUREMENT DEVICES. micro DM-100. micro CM-100. micro HM-100. micro LM-100 Laser Distance Meter

TEST & MEASUREMENT NEW NEW NEW FULL RANGE OF TEST & MEASUREMENT DEVICES. micro DM-100. micro CM-100. micro HM-100. micro LM-100 Laser Distance Meter TEST & MEASUREMENT micro DM-100 Digital Multimeter Drop- & Waterproof micro CM-100 Digital Clamp Meter Versatile, 10 Functions micro HM-100 Temp. Humidity Meter Accurate Measurements FULL RANGE OF TEST

More information

Ultra-Accurate Measurement for Temperature and Voltage

Ultra-Accurate Measurement for Temperature and Voltage Ultra-Accurate Measurement for Temperature and Voltage MEASURpoint is an ultra-accurate instrument for measuring any combination of thermocouple, RTD, and voltage inputs. MEASURpoint is available as a

More information

Portable Data LOGGING SYSTEMS. for Professionals

Portable Data LOGGING SYSTEMS. for Professionals Portable Data LOGGING SYSTEMS for Professionals Introduction SIMEX is a Polish manufacturer and supplier of industrial automation equipment. The company has been in the market for nearly 0 years and offers

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope 3100 Application-specific Portable Data Capture Systems built on the 3100 Data Platform PC Measurement Digital Oscilloscope PC-based Data Logger Data Recorder & Logger Made Easy! Style! Fast & Furious

More information

Leak Current Measurement - Essential to Electrical Safety. LEAK CURRENT HiTESTER ST5540/ST5541. Safety standards measuring instruments

Leak Current Measurement - Essential to Electrical Safety. LEAK CURRENT HiTESTER ST5540/ST5541. Safety standards measuring instruments LEAK CURRENT HiTESTER ST5540/ST5541 Safety standards measuring instruments Leak Current Measurement - Essential to Electrical Safety Introducing a leak current measuring instrument that complies with the

More information