1 Datalogging Conductivity/ TDS Meter Instruction Manual 1

2 TABLE OF CONTENTS 1. INTRODUCTION PANEL DESCRIPTION MEASURING PROCEDURE A General Measurement B Auto and Manual Range Modes C Data Hold D Maximum / Minimum E Data Logger ADVANCED ADJUSTMENTS A Check Remaining Available of Data Points B Clear Memory C Date/Time Setting D Sample Time Setting E Auto Power Off Default Setting F Temperature Unit Default Setting G Temperature Compensation Default Setting H Conductivity (us, ms), TDS (PPM) Default Setting I Escape from Advanced Adjustments BATTERY REPLACEMENT TROUBLESHOOTING OPTIONAL ACCESSORIES OFFSET (ZERO) PROCEDURE CONDUCTIVITY CALIBRATION SPECIFICATIONS WARRANTY

3 1. INTRODUCTION Automatically records up to 16,000 (!) data points in the field along with time and date. Features reads total dissolved solids in TDS or PPM simultaneously displays conductivity and temperature manual or auto-range min-max adjustable ATC coefficient calendar/clock auto power off hold function detachable probe fold-out tripod large easy to read LCD Comes ready to use in a protective foam lined carrying case complete with probe, 4 AA batteries, and one 3V button cell battery. 3

4 2. PANEL DESCRIPTION DISPLAY 2. POWER button 3. HOLD / ESC button 4. REC / ENTER button 5. (UP) button RANGE / (DOWN) button 7. CLOCK/ SEND button 5 (UP) button 6 RANGE / (DOWN) button 7 CLOCK/ SEND button 8 LOGGER / SET button 9 TRIPOD SCREW 10 STAND 11 BATTERY COMPARTMENT/COVER 12 PROBE INPUT 13 LCD BRIGHTNESS ADJUSTMENT VR 14 SYSTEM RESET 8. LOGGER / SET button 9. TRIPOD SCREW 10. STAND 11. BATTERY COMPARTMENT/COVER 12. PROBE INPUT 13. LCD BRIGHTNESS ADJUSTMENT VR 14. SYSTEM RESET 15. DC 9V POWER ADAPTOR SOCKET 16. PROBE PLUG 17. SENSOR HEAD 18. PROBE HANDLE 4

5 3. MEASUREMENT PROCEDURES: See page 4 for button locations. Factory Preset Meter Defaults: Conductivity (us, ms), C, Temperature Compensation (ATC) Factor of 2% per C, Auto Range, Auto Power Off, and 2-Second Data Logger Sampling Time. To change default settings, see ADVANCED ADJUSTMENT PROCEDURES on page 6. 3-A. General Measurement Insert the PROBE PLUG into the PROBE INPUT and turn the meter on pressing the POWER button. Hold the PROBE HANDLE and immerse the SENSOR HEAD into the solution sample to be measured. Gently shake the probe to release any air bubbles. The sample s conductivity ms (us) and the temperature are displayed. See item 4-F, page 8 for instructions on changing between C and F. See item 4-G, page 8 for instructions on changing the Automatic Temperature Compensation (ATC) Factor. The instructions for measuring TDS are the same as the instructions for measuring Conductivity. See item 4-H, page 8 for instructions on changing between Conductivity (us, ms) and TDS (PPM) measurement. To display the time (h-m-s) or date (y-m-d) during use, press the CLOCK button. Press the POWER button to turn the unit off. 3-B. Auto and Manual Range Modes Auto Range or Manual Range is displayed under the measurement. To switch to Manual Range, press and hold the RANGE button for at least 2 seconds. When the meter beeps, release the RANGE button. Press the RANGE button again to switch between the available ranges: 200uS, 2MS 20 ms and 200 ms. If the out-of-range indicator appears at the bottom of the display, select a lower range, and if it appears at the top of the display, select a higher range. To switch to Auto Range, press and hold the RANGE button for at least 2 seconds. When the meter beeps, release the RANGE button. 3-C. Data Hold While measuring, press the HOLD button to freeze the displayed value. HOLD and the measurement are displayed. Press the HOLD button again to exit F ms Auto Range

6 3-D. Maximum / Minimum To record the maximum and minimum readings: Press the REC button once. REC appears on the LCD. Press the REC button again. MAX, REC and the maximum measurement appear on the LCD. Press the REC button again. REC Min and the minimum measurement appear on the LCD. To exit this function, press and hold the REC button for at least 2 seconds. The display reverts to the current reading. 3-E. Data Logger The data logger function can save up to 16,000 data points along with the time (hour-min-sec) and date (year-month-day). When there are 16,000 data points in memory, the display indicates FULL. To momentarily display the set sampling time, press the LOGGER button once. To change the sampling time, see item 4-D on page 7. Press the REC button once, REC will be displayed. Depending on your set sampling time, continue to step a or b (below). a. Auto Data Logger (sampling time can be set for 2 seconds to 8 hours, 59 minutes, 59 seconds): Press the LOGGER button once, REC DATA is displayed and Recording.... flashes at each set interval. Press the LOGGER button again to exit. REC is still displayed, but DATA is no longer shown. To resume data logging, simply press the LOGGER button again. To exit the REC function, press and hold the REC button for at least 2 seconds. b. Manual Memory (sampling time MUST be set to 0 zero) Press the LOGGER button once to save each data point. Up to 250 data points can be saved and reviewed on the meter s LCD by pressing and holding the SEND button and then using and to scroll. To exit the this function, press and hold the ESC button for at least 2 seconds. 4. ADVANCED ADJUSTMENT PROCEDURES Press the SET button for at least two seconds to enter the advanced adjustment procedures. Press the ESC button to exit. Before executing the advanced adjustment procedures, exit the HOLD and RECORD functions. 6

7 4-A. Check Remaining Number of Data Points Press the SET button at least 2 seconds until the lower display shows: XXXXX is the number of free data points. XXXXX Memory Space 4-B. Clear Memory Clear Memory 107 Esc:N Enter:Y Press the SET button as needed to reach the clear memory screen. The number of saved data points is displayed. To delete saved data from memory, press the ENTER button once, then press the ENTER button again to confirm. The display shows: 0 Ok ESC:Quit. If you DO NOT want to clear the memory, press the ESC button to exit, OR press the SET button to advance to the next option. 4-C. Date/Time Setting Press the SET button as needed to reach the date/time set screen. Use the,, and ENTER buttons to select the year, month, date, hours, minutes and seconds. Press the ENTER button to save the settings. Press the SET button to advance to the next option, or press the ESC button to exit. 4-D. Sample Time Setting Press the SET button as needed to reach the sample time screen. Use the,, and ENTER buttons to select the sample time (hour-minsec). Press the ENTER button to save the settings. Press the SET button to advance to the next option, or press the ESC button to exit. 4-E. Auto Power Off Default Setting The meter will automatically shut off after about 10 minutes without activity. Press the SET button as needed to reach the auto power off screen. Use the or buttons to enable / disable this feature. Press the ENTER button to save the settings. Press the SET button to advance to the next option, or press the ESC button to exit. 7 06:01:03 Date/Time Set y-m-d ^, v ENTER( ) 00:00:02 Sample Time h-m-s ^, v ENTER( ) 1=Auto Power Off - Enabled 0=Auto Power Off - Disabled

8 4-F. Temperature Unit Default Setting Press the SET button as needed to reach the temp. unit screen. Use the and buttons to switch between F and C. Press the ENTER button. Press the SET button to advance to the next option, or press the ESC button to exit. 4-G. Temperature Compensation Factor (ATC) Default Setting The ATC Factor is adjustable between 0 to 5.0% per C. Press the SET button as needed to reach the Temp. Comp. screen. Use the,, and SEND buttons to set the ATC Factor. Press the ENTER button to save the settings. Press the SET button to advance to the next option, or press the ESC button to exit. 4-H. Conductivity (us, ms), TDS (PPM) Default Setting Press the SET button as needed to reach the CD/TDS screen. Use the and buttons to switch between us, ms and PPM. Press the ENTER button. Press the SET button to advance to the next option, or press the ESC button to exit. 4-I. Escape from Advanced Adjustments 1= F 0= C Temp. Comp. ^, v SEND( ) 1=PPM 0=uS, ms For the above procedures, press the ESC button before pressing the ENTER button to exit advanced adjustments without saving the changes. 8

9 5. BATTERY REPLACEMENT When the left corner of the LCD displays the low battery icon install 4 new AA 1.5V batteries. Slide the BATTERY COVER away from the instrument to remove the old batteries. When the clock is not accurate, replace the 3V button cell battery located in the compartment behind the AA s. Re-attach the battery cover when you have finished. In-spec measurements may be made for several hours after the low battery indicator appears. 6. TROUBLESHOOTING Gently insert a pin or small object into the SYSTEM RESET while turning on the meter. 7. OPTIONAL ACCESSORIES Replacement Conductivity/TDS Probe USB Power Cable AC to DC 9V Adapter Water Resistant Instrument Pouch Field Tripod 8. OFFSET (ZERO) PROCEDURE With the SENSOR HEAD completely dry, press the button for at least two seconds until the meter beeps and the display changes to zeros. 9

10 9. CONDUCTIVITY CALIBRATION Although calibration is not generally needed, the following procedures should be performed the first time a new probe is used, when the electrode is changed, or after the meter has been in use for a long period of time. Prepare a µs calibration solution, or any standard conductivity solution. Press the POWER button to turn the meter on. Select the auto range mode, see item 3-B, page 5. Immerse the SENSOR HEAD into the solution. Press both the REC and HOLD buttons at the same time. Release the buttons when 0:Temp.,1:CD is displayed. Use the and buttons to select 1 for Conductivity Calibration or 0 for Temperature Calibration. Press the ENTER button. 1=Conductivity Calibration 0=Temp. Calibration Use the and buttons to select the desired calibration value, for example Press the ENTER button twice to save the setting and exit the function µs C µs C The same steps are used to calibrate 200uS, 2mS, 20mS, and 200mS. Each range can be independently calibrated. 10

11 10. SPECIFICATIONS Range Resolution Accuracy 0 to us 0.1 us Conductivity 0.2 to ms ms 2 to ms 0.01 ms 20 to ms 0.1 ms 0 to 132 ppm 0.1 ppm ±(2% full scale +1d) TDS 132 to 1,320 ppm 1 ppm 1,320 to 13, ppm 13,200 to 132, ppm ºC 0 to 60ºC 0.1º 0.8ºC ºF 32 to 140ºF 1.5ºF Operating Conditions Display Sampling Time Display Size Meter dimensions: Weight: Sampling Time of Display Power Current Circuit 0 to 50 C, Less than 80% RH Approximately 1 second LCD size 2 1/4" x 1 3/8" (58 x 34 mm) Meter: 7 ¾" x 3" x 1½" (200 x 76 x 37 mm) Probe handle diameter: 1 (26 mm) Probe handle length: 5 (127 mm) Cable length: 44 (1118 mm) 31 oz (515g) Approx 1 second Approx. DC 19.0 ma Custom one-chip microprocessor LSI 11

12 11. WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD E. Evans Rd., Suite #103 Scottsdale, AZ (480) The defective unit must be accompanied by a description of the problem and your return address. Register your product online at within 10 days of purchase. 12 Rev 3/8/2018

Datalogging Hot Wire CFM Anemometer

Datalogging Hot Wire CFM Anemometer Datalogging Hot Wire CFM Anemometer 840002 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS 1. INTRODUCTION... 3 2. PANEL DESCRIPTION... 4-5 3. MEASURING PROCEDURE... 5 3-A Air Velocity and Ambient

More information

Torque Meter. Instruction Manual

Torque Meter. Instruction Manual Torque Meter 840062 Instruction Manual Torque Meter - 840062 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in

More information

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Dissolved Oxygen Meter Kit DOK. Instruction Manual Dissolved Oxygen Meter Kit 850081DOK Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email:

More information

Vacuum Meter Instruction Manual

Vacuum Meter Instruction Manual Vacuum Meter 840064 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...2 2. METER DESCRIPTION...3 3. OPERATING INSTRUCTIONS 3-A PRECAUTIONS - READ BEFORE FIRST USE...4 3-B MEASUREMENT PROCEDURE...4

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850070 Mini Environmental Quality Meter 850070 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

RH/Temperature SD Card Datalogger. Instruction Manual

RH/Temperature SD Card Datalogger. Instruction Manual RH/Temperature SD Card Datalogger 800021 Instruction Manual RH/Temperature SD Card Datalogger 800021 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual

More information

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual Water Quality Meter 850081 Water Quality Meter Kit 850086 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax:

More information

Anemometer SD Card Datalogger. Instruction Manual

Anemometer SD Card Datalogger. Instruction Manual Anemometer SD Card Datalogger 850023 Instruction Manual 1 Anemometer SD Card Datalogger 850023 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not

More information

Visible Light SD Card Datalogger

Visible Light SD Card Datalogger Visible Light SD Card Datalogger 850007 Instruction Manual Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand Tel: 66-3844-6117 sale@ete.co.th www.eastern-energy.com Visible

More information

Wide Range Pressure Meter Instruction Manual

Wide Range Pressure Meter Instruction Manual Wide Pressure Meter 840065 Instruction Manual Wide Pressure Meter - 840065 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or

More information

Light Meter (Foot Candles)

Light Meter (Foot Candles) Light Meter (Foot Candles) 821 Light Meter (Foot Candles) - 821 Copyright 215 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

Advanced Datalogging Thermometer. Instruction Manual

Advanced Datalogging Thermometer. Instruction Manual Advanced Datalogging Thermometer 800008 Instruction Manual Advanced Datalogging Thermometer - 800008 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual

More information

Light Meter with Bar Graph

Light Meter with Bar Graph Light Meter with Bar Graph 840020 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 MEASUREMENT PROCEDURES... 3-4 ZERO ADJUSTMENT... 4 BATTERY REPLACEMENT...

More information

4-Channel Thermometer

4-Channel Thermometer 4-Channel Thermometer 800023 4-Channel Thermometer - 800023 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in

More information

4-Channel Datalogging Thermometer

4-Channel Datalogging Thermometer 4-Channel Datalogging Thermometer 800024 4-Channel Datalogging Thermometer - 800024 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced

More information

Anemometer/Thermometer

Anemometer/Thermometer Anemometer/Thermometer 840003 840003 Anemometer/ Thermometer measures both air speed and temperature in a light weight, compact unit. Measures air velocity in 5 scales: m/s, km/hr, mile/ hr, knots, or

More information

DIGITAL SOUND LEVEL METER. Instruction Manual

DIGITAL SOUND LEVEL METER. Instruction Manual DIGITAL SOUND LEVEL METER 840029 Instruction Manual CONTENTS I. Introduction... 3 II. Panel Description... 3 III. Operating Instructions A. Measuring Procedure... 4 B. Settings for General Applications...

More information

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA Oxygen Pen 800047 Oxygen Pen - 800047 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means

More information

Psychrometer/Anemometer. Instruction Manual

Psychrometer/Anemometer. Instruction Manual Psychrometer/Anemometer 840034 Instruction Manual 1 2 TABLE OF CONTENTS Introduction...4 Front Panel Description...5 Measurement Procedures...8 Low Battery...16 USB Software...17 Troubleshooting...18 Error

More information

Sound Level Pen Instruction Manual

Sound Level Pen Instruction Manual Sound Level Pen 840018 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...................2 2. DESCRIPTION.................... 3 3. OPERATING INSTRUCTIONS........... 4 PRECAUTIONS AND MAINTENANCE.......4

More information

Datalogging RH / Temperature Pen Instruction Manual

Datalogging RH / Temperature Pen Instruction Manual Datalogging RH / Temperature Pen 800013 Instruction Manual 1 Datalogging RH / Temperature Pen 800013 Copyright 2014 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual

More information

Datalogging ph Meter

Datalogging ph Meter Specifications Range Resolution Accuracy ph 0.00 ~ 14.00 ph 0.01 ph ±0.02 ph mv -999.9 ~ 999.9mV 0.1 mv ±0.2 mv @ -99.9 ~ 99.9mV ±2 mv @ other ranges Temperature -23 ~ 176 F (-5 ~ 80 C) 0.1 F( 0.1 C) Compensation

More information

Dissolved Oxygen Meter

Dissolved Oxygen Meter Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge.

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850025 Mini Environmental Quality Meter 850025 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

WBGT SD Card Datalogger. Instruction Manual

WBGT SD Card Datalogger. Instruction Manual WBGT SD Card Datalogger 800037 Instruction Manual 1 WBGT SD Card Datalogger 800037 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

Torque Meter. Instruction Manual

Torque Meter. Instruction Manual Torque Meter 840062 Instruction Manual CONTENTS I. Introduction... 4 II. Meter Description... 4 III. Operating Instructions 1. Measuring Procedures... 5 2. Automatic Shut Off... 6 3. Battery Replacement...

More information

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , , Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI 840080, 840081, 840082 840083, 840085 Manometers 840080, 840081, 840082, 840083, 840085 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the

More information

Datalogging IAQ Meter Instruction Manual

Datalogging IAQ Meter Instruction Manual Datalogging IAQ Meter 800050 Instruction Manual Datalogging IAQ Meter 800050 Copyright 2014 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or

More information

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL PROGRAMMABLE DIGITAL REFRACTOMETER 300037 INSTRUCTION MANUAL 1 CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 FACEPLATE & LCD DISPLAY...3 OPERATING INSTRUCTIONS General Measurement...4 Calibration Procedures...4

More information

Type K/J Thermometers

Type K/J Thermometers Type K/J Thermometers 800005 CONTENTS INTRODUCTION....2 FRONT PANEL DESCRIPTION...3 LCD DISPLAY....4 OPERATION INSTRUCTION...5 Power Up....5 Connecting the Thermocouples....5 Selecting Temperature Scale....5

More information

AquaShock ph Meter K

AquaShock ph Meter K AquaShock ph Meter 850057K 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com AquaShock ph Meter 850057K Copyright 2011 by Sper Scientific

More information

Large Display Salinity & Conductivity Pens &

Large Display Salinity & Conductivity Pens & Large Display Salinity & Conductivity Pens 850036 & 850037 Large Display Salinity & Conductivity Pens 850036 & 850037 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents

More information

WBGT SD Card Datalogger. Instruction Manual

WBGT SD Card Datalogger. Instruction Manual WBGT SD Card Datalogger 800037 Instruction Manual WBGT SD Card Datalogger 800037 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

Bluetooth IR Pen. Instruction Manual

Bluetooth IR Pen. Instruction Manual Bluetooth IR Pen 800110 Instruction Manual 1 INTRODUCTION Simply choose single, or continuous, monitoring on the App and aim the laser circle guide at the target to read the temperature. The laser circle

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850025 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com Mini Environmental Quality Meter 850025 Copyright

More information

PH SD Card Datalogger. Instruction Manual

PH SD Card Datalogger. Instruction Manual PH SD Card Datalogger 850060 Instruction Manual PH SD Card Datalogger 850060 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or

More information

4 Channel Datalogging Thermometer. Instruction Manual

4 Channel Datalogging Thermometer. Instruction Manual 4 Channel Datalogging Thermometer 800024 Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 4 MATERIALS SUPPLIED... 4 FRONT PANEL DESCRIPTION... 5 LCD DISPLAY... 6 SET UP... 7 MEASUREMENT

More information

DO Meter Kit. Instruction Manual

DO Meter Kit. Instruction Manual DO Meter Kit 850048 Instruction Manual DO Meter Kit 850048 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any

More information

Datalogging Manometer

Datalogging Manometer Datalogging Manometer 840086, 840098 and 840099 Instruction Manual TABLE OF CONTENTS Introduction.. 3 Front Panel Descriptions.. 4 Set-up.. 5-6 Calibration.. 7 Measurement Procedures.. 8-14 Error Codes..

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850026 Mini Environmental Quality Meter 850026 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC Mini Sound Meter 850014 Instruction Manual SPER SCIENTIFIC CONTENTS 1. INTRODUCTION... 2 2. PANEL DESCRIPTION... 3 3. OPERATING INSTRUCTIONS... 4 3-A. Measuring Procedures... 4 3-B. Hold Function... 5

More information

Datalogging Manometers 2PSI, 5PSI, 15PSI , ,

Datalogging Manometers 2PSI, 5PSI, 15PSI , , Datalogging Manometers 2PSI, 5PSI, 15PSI 840086, 840098, 840099 Manometers 840086, 840098, 840099 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA FIRST TIME USE Before using the

More information

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC SOUND LEVEL PEN 840018 INSTRUCTION MANUAL SPER SCIENTIFIC CONTENTS I. Introduction... 2 II. Description... 3 III. Operating Instructions... 4 Precautions and Maintenance.. 4 Calibration... 4-5 Measurement...

More information

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322 1,600 point data logger, RS232, AC/DC adapter 2,000 us 20 ms, 100 ms, auto range, auto calibration CONDUCTIVITY METER Model : CD-4322 Your purchase of this CONDUCTIVITY METER marks a step forward for you

More information

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER.

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER. SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER Model : CD-4318SD Your purchase of this CONDUCTIVITY METER with SD CARD DATA LOGGER

More information

User Guide. Conductivity Meter. Model EC210

User Guide. Conductivity Meter. Model EC210 User Guide Conductivity Meter Model EC210 Introduction Thank you for selecting the Extech EC210 conductivity meter which simultaneously displays conductivity and Temperature. Conductivity is measured with

More information

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER. 3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, 16000 Data logger no., RS232 THERMOMETER Model : YK-2005TM TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 2-1 General

More information

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315 Humidity + Temp. + Dew Point Pocket size HUMIDITY METER Model : HT-315 TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 3. FRONT PANEL DESCRIPTION...5 3-1 Display...5 3-2 Power Button...5 3-3 Hold

More information

Thermal Imaging Camera 220 x Instruction Manual

Thermal Imaging Camera 220 x Instruction Manual Thermal Imaging Camera 220 x 160 800201 Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 4 MATERIALS SUPPLIED... 4 FRONT PANEL DESCRIPTION... 5 LCD DISPLAY... 6 SET UP... 7 MEASUREMENT

More information

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this G ( Gauss), mt ( milli Tesla ), USB/RS232 AC/DC MAGNETIC METER Model : MG-3002 Your purchase of this AC/DC MAGNETIC METER marks a step forward for you into the field of precision measurement. Although

More information

Temperature Datalogger

Temperature Datalogger Temperature Datalogger 800057 INTV 800057 INSTRUCTION MANUAL 3 Sec Erase MEMORY SELECT 1 Sec REC Data Logger: 64,000 Records SPER SCIENTIFIC LTD. CONTENT Page I. SAFETY INFORMATION ---------------------

More information

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC 2. Open the file by selecting All Types or Text in the Files of type: box. Find the file you saved. When open, choose Tab delineated file. 3. You can now work with the data as you would any other data

More information

Professional Benchtop Conductivity meter BC3020

Professional Benchtop Conductivity meter BC3020 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 Professional Benchtop Conductivity meter BC3020 Operation Manual 0 INTRODUCTION Your purchase of this professional benchtop Conductivity

More information

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD.

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD. DIGITAL REFRACTOMETERS 300033, 300034, 300035, 300036 INSTRUCTION MANUAL SPER SCIENTIFIC LTD. CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions General Measurement...

More information

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this G ( Gauss), mt ( milli Tesla ), USB/RS232 AC/DC MAGNETIC METER Model : PCE-MFM 3000 Your purchase of this AC/DC MAGNETIC METER marks a step forward for you into the field of precision measurement. Although

More information

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008 Carbon monoxide 0 to 1000 PPM, Temp. CO METER Model : GCO-2008 Your purchase of this CO METER MONITOR marks a step forward for you into the field of precision measurement. Although this CO METER is a complex

More information

POCKET DIGITAL REFRACTOMETERS ~

POCKET DIGITAL REFRACTOMETERS ~ POCKET DIGITAL REFRACTOMETERS 300051 ~ 300055 INSTRUCTION MANUAL SPER SCIENTIFIC LTD. CONTENTS 1. Introduction... 3 2. Panel Description... 4-5 3. Calibration... 6 4. Measurement... 7 Models with Multiple

More information

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments Model SD-3007 Humidity/Temperature Datalogger Instruction Manual reedinstruments com 1-877-849-2127 info@reedinstruments.com.reedinstruments.com Table of Contents Features... 3 Specifications...3-5 Instrument

More information

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810 Operation Manual Hand-held ph/mv/temperature Meter ph6810 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4

More information

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M Operation Manual Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS

More information

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Operation Manual. Hand-held ph/orp/temperature Meter 6010M Operation Manual Hand-held ph/orp/temperature Meter 6010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......3 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4

More information

Operations Manual EcoSense ph100a

Operations Manual EcoSense ph100a Operations Manual EcoSense ph100a Portable ph, mv and Temperature Instrument English CONTENTS GENERAL INTRODUCTION... 3 INITIAL INSPECTION... 3 THE INSTRUMENT... 3 BATTERY INSTALLATION... 3 Battery Disposal...

More information

TestLink Software for Software Instruction Manual

TestLink Software for Software Instruction Manual TestLink Software for 800023 840004 Software Instruction Manual 1 Table of Contents Introduction... 3 System Requirements... 3 Minimum Hardware Requirement... 3 Quick Start Tutorial... 4 Recording real

More information

DPH230SD USER S MANUAL

DPH230SD USER S MANUAL DPH230SD USER S MANUAL ph METER WITH DATALOGGING SD CARD Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction................................. 3 Key

More information

Advanced Datalogging Sound Meter Instruction Manual

Advanced Datalogging Sound Meter Instruction Manual Advanced Datalogging Sound Meter 850013 Instruction Manual Advanced Datalogging Sound Meter - 850013 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual

More information

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL Air velocity, Air flow, Type K/J thermometer Real time data logger, 16000 Data logger no., RS232 ANEMOMETER Model : DAF2005MDL TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 2 3. FRONT PANEL DESCRIPTION...6

More information

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407303 Product Page Heavy Duty Conductivity / Temperature

More information

Operations Manual EcoSense ph100

Operations Manual EcoSense ph100 Operations Manual EcoSense ph100 Portable ph, mv and Temperature Instrument English Français Español Deutsch Italiano WARRANTY The EcoSense ph100 Instrument is warranted for one year from date of purchase

More information

PM2.5 and PM10 Monitors , & Instruction Manual

PM2.5 and PM10 Monitors , & Instruction Manual 1 PM2.5 and PM10 Monitors 900014, 900015 & 900016 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117 Fax: 0-3844-6200

More information

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R Operation Manual MODEL 3173/3173R MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R INITIAL INSPECTION..... 2 GENERAL INTRODUCTION.. 2 USING THE METER. 3 THE DISPLAY....

More information

4-Channel Thermometer / Datalogger

4-Channel Thermometer / Datalogger User's Guide 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This

More information

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER Model : AM-4220 Your purchase of this ANEMOMETER marks a step forward for you into the field of p r e c i s i o n measurement. Although this METER

More information

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD Your purchase of this CO2 METER,+ HUMIDITY/Temp. with SD CARD DATA RECORDER

More information

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER MMD7003 USER S MANUAL DIGITAL and LED PRECISION MOISTURE METER INTRODUCTION: Congratulations on your purchase of this Digital and LED Precision Moisture Meter. This unit detects moisture in wood and other

More information

12-Channel Thermocouple Datalogger

12-Channel Thermocouple Datalogger User Manual 12-Channel Thermocouple Datalogger Model TM500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech TM500 Thermometer,

More information

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this SOIL MOISTURE METER Model : DSMM500 Your purchase of this SOIL MOISTURE METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument,

More information

ph/orp Meter SD Card real-time Datalogger

ph/orp Meter SD Card real-time Datalogger User's Guide ph/orp Meter SD Card real-time Datalogger Model SDL100 Introduction Congratulations on your purchase of the Extech SDL100 ph/orp Meter, an SD Logger Series meter. This meter displays and stores

More information

Hygro-Thermometer / Datalogger

Hygro-Thermometer / Datalogger USER GUIDE Hygro-Thermometer / Datalogger Model SDL500 Introduction Congratulations on your purchase of the Extech SDL500 Hygro-Thermometer, an SD Logger Series meter. This meter displays and stores Temperature

More information

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Cup Thermo-Anemometer. Model AN400 User's Guide Cup Thermo-Anemometer Model AN400 Introduction Congratulations on your purchase of the Extech Cup Thermo-Anemometer. The AN400 measures air velocity in five units of measure: feet per minute

More information

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT Pool Professional s Meter TRACER EC/TDS/SAL POCKETESTER TM CODE 1749-KIT TABLE OF CONTENTS Introduction... 4 Specifications... 4 Contents... 5 Parts &

More information

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER 40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER Model : LX-1102 Your purchase of this LIGHT METER marks a step forward for you into the field of precision measurement. Although this LIGHT METER is a complex

More information

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD ph/mv SD card real time data logger ph METER Model : PH-230SD Your purchase of this ph METER with SD CARD DATA LOGGER marks a step forward for you into the field of precision measurement. Although this

More information

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments Model Heat Stress Meter and Datalogger Instruction Manual SD-2010 reedinstruments com 1-877-849-2127 info@reedinstruments.com.reedinstruments.com Table of Contents Features... 3 Specifications...4-5 Instrument

More information

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250 Pen type, air oxygen and Temp. O2 METER Model : PO2-250 Your purchase of this OXYGEN METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate

More information

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303 CODUCTIVITY METER Model : CD-4303 Your purchase of this PRESSURE METER marks a step forward for you into the field of precision measurement. Although this PRESSURE METER is a complex and delicate instrument,

More information

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax: MOISTURE METER Operation Manual MS-7003 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.06.14 TABLE OF CONTENTS

More information

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter Operation Manual MODEL ph6175 Microcomputer Based ph/orp/temperature Benchtop Meter ph6175 0 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 POWER INPUT.......2 INSTALLING THE BATTERIES.....3

More information

AC/DC MAGNETIC METER

AC/DC MAGNETIC METER G ( Gauss), mt ( milli Tesla ) SD card real time data logger AC/DC MAGNETIC METER Model : MG-3003SD Your purchase of this AC/DC MAGNETIC METER with SD CARD DATA LOGGER marks a step forward for you into

More information

WalkLAB ph mv/orptemperature

WalkLAB ph mv/orptemperature 16,1,16,1,2,15,2,15,14,3,14,3,4,13,4,13,12,5,12,5,6,11,6,11,10,7,10,7,8,9,8,9 WalkLAB ph mv/orptemperature meter HP9000 Operations Manual TABLE OF CONTENTS PAGE 1. INTRODUCTION 1 1.1 Features 1 1.2 Technical

More information

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com Model 8706 Digital Pocket Psychrometer Instruction Manual reedinstruments com Table of Contents Features... 3 Specifications... 4 Instrument Description... 5 Measuring Procedures... 6--9 Auto Power Off...

More information

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713 all in one MOISTURE METER Model : PMS-713 Your purchase of this MOISTURE METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument,

More information

I/R Thermometer Gun 8:1

I/R Thermometer Gun 8:1 I/R Thermometer Gun 8:1 800101, 800102 INSTRUCTION MANUAL SPER SCIENTIFIC Contents Page 1. INTRODUCTION...2 2. SAFETY SPECIFICATIONS...3 3. DISPLAY AND BUTTON LOCATIONS...4 4. BATTERY REPLACEMENT...5 5.

More information

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions User's Guide Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions SD Card real-time datalogger Model SDL550 %RH Moisture Content Meter SDL550 Introduction Congratulations

More information

Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter

Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter English Cond Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket

More information

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting

More information

User Guide. Moisture Meter. Model MO250

User Guide. Moisture Meter. Model MO250 User Guide Moisture Meter Model MO250 Introduction Congratulations on your purchase of the Extech MO250 Moisture Meter. The MO250 detects moisture in wood and other building materials such as brick, wall

More information

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 WalkLAB Professional Conductivity-TDS-Salinity Meter HC 9021 Operations Manual 0 INTRODUCTION

More information

Heavy Duty Datalogger Module

Heavy Duty Datalogger Module User's Guide Heavy Duty Datalogger Module Model 380340 Introduction Congratulations on your purchase of Extech s 380340 Datalogger Module. The Datalogger connects to and records data from Extech Heavy

More information

Vibration Meter SD Card real-time datalogger

Vibration Meter SD Card real-time datalogger User's Guide Vibration Meter SD Card real-time datalogger Model SDL800 Introduction Congratulations on your purchase of the Extech SDL800 Vibration Meter. This meter displays and stores vibration readings

More information

Manual ph Meter PCE-228

Manual ph Meter PCE-228 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information