Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
|
|
- Ralf Cross
- 6 years ago
- Views:
Transcription
1 r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application requirements NEMA enclosure enables the MA Series switches to satisfy most application requirements (MA,, are NEMA ) Misalignment tolerant the non-contact actuation of the switches makes them very tolerant to misalignment of up to 0 mm (0.9 in.) Variety of terminations select various cable lengths or terminal strip termination for easy installation. Cable connector on selected models. Long life the MA Series is designed for a minimum of one million actuations Specifications C US Conforms to EN088, EN9, EN00- UL and C-UL listed Electrical All Models Unless Indicated Safety Contacts: AC models MA- thru, 0,,, N/C MA-,, N/C DC models MA-,,, N/C MA-,,, 0, N/C Safety Contact Operating Distance: Make 7- mm ( in.); Break - mm ( in.) Auxiliary Contacts: MA-,,,,,,, N/O MA- N/C Aux. Contact Operating Distance: MA-,,, Make 8- mm ( in.); Break 8-0 mm ( in.) MA- Make mm (0.8 in.); Break mm (0.9 in.) Safety Rated Voltage: AC models: All except MA-0 0 VAC AC models: MA-0 0 VAC DC models 0 VDC Safety Rated Current: AC models: All except MA- A, fuse externally. A quick acting AC model: MA- A, fuse externally. A quick acting DC models: All except MA- A, fuse externally 800 ma quick acting DC model: MA- 0. A max., fuse externally 0. A quick acting Internal Fuse: AC models A fast acting DC models A fast acting External Fuse (Customer Supplied): AC models. A fast acting DC models: All except MA- 0.8 A fast acting Electrical Life: x 0 Mechanical Special Safety Reed Safety Aux. Closing Time:.0 ms 0. ms Drop-Out Time:. ms 0. ms Bounce Time: 0.7 ms 0.7 ms Shock: 0 0 Vibration: 0, 0 to 00 Hz Mechanical Mounting: Any position Case & Actuator Material: Molded ABS Wiring Connection: Various lengths or male M micro connector Weight: Approx. 8 g ( oz.) Color: Red Mechanical Life: 0 x 0 Environmental Protection: All models except MA-,, IP7 (NEMA ) MA-,, IP (NEMA ) Operating Temperature: All models except MA-,, -0 to C ( to F) MA-,, -0 to C ( to 9 F) Compliance Standards: EN088, EN9, EN00- Approvals/Listings: CE marked for all applicable directives All models: except MA-,, UL and C-UL MA-,, ccsaus Specifications are subject to change without notice. Note: The safety contacts of the Omron STI switches are described as normally closed (N/C) i.e., with the guard closed, actuator in place, and the machine able to be started. USA Tel. /888/0-7 Canada Tel. /8/98-7
2 Basic Body Styles MA-, MA-, MA-0 and MA- MA-0 and MA- MA- and MA- MA- and MA- MA-, MA- and MA- Operation Operating Principle Mounting Examples Contact Arrangement mm MA-,, 0,,,,, Min 0mm MA-,,,,,, Encapsulated in the MA Series is a unique high-power industrial reed which is de-rated by a non-resetable overload protection circuit depending on switch type. On presenting the actuator to the switch, the high intensity magnetic field from the actuator causes the contacts to close. On removing the actuator (opening the door), the safety contacts open, isolating the machine. Door Closed, Machine RUN Switch Actuator Door Switch Actuator Door It is advisable, where possible, to mount the switch and actuator on non-ferrous materials otherwise it may affect the operating distances. MA-,,,, 0 Door Open, Machine STOP, Door Covering Switch MA-,,,, mm SLIDIN DOOR No access to switch thus preventing attempts to defeat the interlock SLIDIN DOOR Wherever possible the units should be mounted so that no access can be obtained to the switch when the guard door is open, thus preventing attempts to defeat the safety system. USA Tel. /888/0-7 Canada Tel. /8/98-7
3 Applications Typical Application of MA Series with a Safety Monitoring Relay Typical applications are on sliding guard doors or swinging guard doors. VAC/DC, 0 VAC K (AUX) START MOMENTARY PUSH BUTTON K (AUX) L L L L L L UARD CLOSED STOP MOMENTARY PUSH BUTTON EB SERIES LATCHIN E-STOP BUTTON BLUE BROWN FUSE MA SERIES INTERLOCK A S S Power supply (S V) A SR0A K Relay control and fault monitoring + K + FUSE K K FUSE K CONTACT PROTECTION e.g. THERMAL CUT OUT M K CONTACT PROTECTION e.g. THERMAL CUT OUT M For a full explanation of the circuit operating principle and fault detection, see Common Circuit Examples in The Safety Library Section of this catalog on page A Pin Assignments with Connector Option MA QD -pin Micro AC / -0 Safety N.C. Safety N.C. Aux N.O. MA QD MA QD MA 0 QD MA,, 0 QD Safety N.C. -pin Micro DC M Aux MA QD N.O. MA 0 QD N.C. USA Tel. /888/0-7 Canada Tel. /8/98-7 7
4 Dimensions (mm/in.) MA-,, 0, MA ACTUATOR ACTUATOR. MA-,, HOLES THRU ACTUATOR MA-, 8.0 Ø. Ø SIDE VIEW 0. MA- MA MA ACTUATOR ACTUATOR ACTUATOR USA Tel. /888/0-7 Canada Tel. /8/98-7
5 Ordering Model Contacts Wiring Entry Part No. AC Only MA-APC (AC only) N/C m cable, pre-wired MA-APC (AC only) N/C m cable, pre-wired MA-APC8 (AC only) N/C 8 m cable, pre-wired MA-APCC (AC only) N/C pin micro DC M MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC0 (AC only) N/C + N/O 0 m cable, pre-wired MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APCC (AC only) N/C + N/O -pin micro DC M MA-APTC (AC only) N/C + N/C Terminal connections MA-APTC (AC only) N/C + N/O Terminal connections MA-APTC (AC only) N/C Terminal connections MA-0APC (0 VAC, A max) N/C m cable, pre-wired MA-0APC (0 VAC, A max) N/C m cable, pre-wired MA-AP0C N/C m cable, pre-wired 07-0 MA-APC N/C + N/O m cable, pre-wired 07-0 MA-AP0C N/C m cable, pre-wired 07-0 MA-APC N/C + N/O m cable, pre-wired 07-0 MA-AP0C N/C m cable, pre-wired MA-APC N/C + N/O m cable, pre-wired MA-AP0C (AC only) N/C m cable, pre-wired 07-0 MA-AP0C (AC only) N/C m cable, pre-wired 07- MAAP0C0 (AC only) N/C 0 m cable, pre-wired 07-9 MAAP0CC N/C -pin micro DC M 07- MA-APC (AC only) N/C + N/O m cable, pre-wired 07-0 MA-APC (AC only) N/C + N/O m cable, pre-wired 07- MA-AP0C (AC only) N/C m cable, pre-wired MA-AP0C (AC only) N/C m cable, pre-wired 07-7 MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC (AC only) N/C + N/O m cable, pre-wired 07-8 MA-0APC (AC only) N/C m cable, pre-wired 07-0 MA-0APCC (AC only) N/C -pin micro DC M MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC (AC only) N/C + N/O m cable, pre-wired MA-APC0 (AC only) N/C + N/O 0 m cable, pre-wired MA-APC N//C + N/O m cable, pre-wired MA-APCC N/C + N/O -pin micro DC M Highlighted Rapid Delivery products are available for shipment today or within FIVE days. (Continued on next page) USA Tel. /888/0-7 Canada Tel. /8/98-7 9
6 Ordering (continued) Model Contacts Wiring Entry Part No. DC Only MA-DPC N/C m cable, pre-wired MA-DPC N/C m cable, pre-wired MA-DPC8 N/C 8 m cable, pre-wird MA-DPCC N/C p-pin micro DC M MA-DPC N/C + N/O m cable, pre-wired MA-DPC N/C + N/O m cable, pre-wired MA-DPC N/C + N/O m cable, pre-wired MA-DPC0 N/C + N/O 0 m cable, pre-wired MA-DPC N/C + N/O m cable, pre-wired MA-DPCC N/C + N/O -pin micro DC M MA-DP0C N/C m cable, pre-wired 07-0 MA-DPC N/C + N/O m cable, pre-wired 07-0 MA-DP0C N/C m cable, pre-wired 07-0 MA-DPC N/C + N/O m cable, pre-wired 07-0 MA-DP0C N/C m cable, pre-wired 07-0 MA-DPC N/C + N/O m cable, pre-wired 07-0 MA-DPC0 N/C + N/O 0 m cable, pre-wired 07- MA-DP0C N/C m cable, pre-wired 07-0 MA-DPC N/C + N/O m cable, pre-wired 07-0 MA-DPC* N/C + N/O m cable, pre-wired (00 ma max.) 07-0 MA-DPC* N/C + N/O m cable, pre-wired (00 ma max.) 07- MA-DPCC* N/C + N/O -pin micro DC M 07-9 MA-DP0C (DC only) N/C m cable, pre-wired 07-0 MA-DP0C (DC only) N/C m cable, pre-wired 07- MADP0C0 (DC only) N/C 0 m cable, pre-wired 07- MADP0CC (DC only) N/C -pin micro DC M 07-9 MA-DPC (DC only) N/C + N/O m cable, pre-wired 07-0 MA-DPC (DC only) N/C + N/O m cable, pre-wired 07- MA-DP0C (DC only) N/C m cable, pre-wired 07-0 MA-DP0C (DC only) N/C m cable, pre-wired 07- MA-DPC (DC only) N/C + N/O m cable, pre-wired 07-0 MA-DPC (DC only) N/C + N/O m cable, pre-wired 07- MA-0DPC ( VDC only) N/C m cable, pre-wired MA-0DPCC ( VDC only) N/C -pin micro DC M MA-DPC ( VDC only) N/C + N/O m cable, pre-wired MA-DPC ( VDC only) N/C + N/O m cable, pre-wired MA-DPC ( VDC only) N/C + N/O m cable, pre-wired MA-DPC0 ( VDC only) N/C + N/O 0 m cable, pre-wired MA-DPC ( VDC only) N/C + N/O m cable, pre-wired MA-DPCC N/C + N/O -pin micro DC M Accessories Spare Actuator ( & 0, ), Red ABS Plastic Replacement Actuator for MA-, Red ABS Plastic Replacement Actuator for MA-, Red ABS Plastic Replacement Actuator for MA-, Red ABS Plastic Replacement Actuator for MA-, Red ABS Plastic Replacement Actuator for MA-, Red ABS Plastic Replacement Actuator for MA-, -0 Red ABS Plastic *MA- switches are not compatible with the following Omron STI safety relays: SR0M, SR0AM, SR08AD, SR09AD and all Legacy Relays. Highlighted Rapid Delivery products are available for shipment today or within FIVE days. Universal Mounting Brackets can be used with this product. See page 7 for details. 0 USA Tel. /888/0-7 Canada Tel. /8/98-7
For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationSafety Interlock Switches
r Safety Interlock Switches Compact Universal Tongue- Operated Safety Interlock Switch Strong and versatile the compact size of the strong, glass-filled polyester housing can be used in many applications
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock
More informationCM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches
R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic
More informationSafety Door Switches. Contents. Selection Guide F-2. Tongue Switches D4NS F-6 T5009 & T F-14 T4012 F-20 T4016 F-20 T2008 F-21 D4GS-N F-26
Safety Do Switches Contents Selection Guide F-2 Tongue Switches D4NS F-6 T5009 & T5009-6 F-14 T4012 F-20 T4016 F-20 T2008 F-21 D4GS-N F-26 Guardlocking Switches D4SL-N F-27 D4NL F-45 TL4019 F-55 TL4024
More informationSafety Monitoring Relays
Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationUniversal Tongue-Operated Safety Interlock Switch
Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,
More information24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN
Safety Interlock Switches TL8012-S Versatile Safety Interlock Switch with Guard Door Locking High locking force of 2000 N (450 lb.) locks guard door shut until machine is safe to enter NEMA 6 enclosure
More informationManually Operated Bolt Safety Interlock Switch. NEMA 6 enclosure enables the BL6009 switch to withstand water washdown cleaning
C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed BL6009 Manually Operated Bolt Safety Interlock Switch n uard locking manually operated bolt requires up to 20 seconds to retract,
More informationSafety Mats & Area Guarding
Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where
More informationmust Operate Voltage (V)
force-guided relays g7sa G7SA compact, Slim relays conforming to en Standards Relays with forcibly guided contacts (EN50205 Class A, certifi ed by VDE) Supports the CE marking of machinery (Machinery Directive)
More informationBulletin 800Z Zero-Force Touch Buttons
Bulletin 800Z Zero-Force Touch Buttons IEC and NEMA Style General Purpose Range Heavy Industrial Range Protection Class 4/4X/3 and 4/3 IP66 Internationally Rated Ergonomically Designed Touch Buttons Table
More informationMA Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Declaration of Conformity
, Technology & Innovation MA Series Operating Instructions for MA-11 Switches KEEP THIS GUIDE FOR FUTURE REFERENCE This information is designed to help suitably qualified personnel install and operate
More informationCompact Magnetic Non-contact Safety Switches. Model Number Structure
Compact Non-contact Safety Switches Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis. Coded actuator
More informationMagnetic Style Safety Interlock Switches
Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationSafety Monitoring Relays
Safety Monitoring Relays G9SA G9SA Safety Relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller.
More informationTongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.
1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.
More informationVersatile Safety Interlock Switch with Guard Door Locking
Rev..11 C R US Confms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed TL8012-S Versatile Safety Interlock Switch with uard Do Locking High locking fce of 2000 N (450 lb.) locks guard do shut
More informationCompact Magnetic Non-contact Safety Switches. Model Number Structure
Compact Non-contact Safety Switches FS-TGR-N@C Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis.
More informationSpecifications. Functional Safety Data Note: For up-to-date information, visit Certifications.
Safety Non-Contact General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern.
More informationSensaGuard. Description. Features. Benefits. Specifications
SensaGuard Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern. At the same time, flexibility and productivity are points
More informationRemote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)
File no. LR90200 Description mats and edges MC3, MC4 and Safety Mat Controllers Both metal enclosure and DINrail mount models available Control reliable Remote access to status, test and reset functions
More informationSpecifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)
General Principles 9-10-Safety Logic Power General Purpose 800Z-GF2Q5 Heavy Industrial 800Z-HF1 General Purpose 800Z-GL3Q5B Heavy Industrial 800Z-HL1Y Bulletin 800Z Zero-Force are designed for use by machine
More informationMagnetic Non-contact Safety Switches. Model Number Structure
Magnetic Non-contact Safety Switches Reed non-contact switches monitor the status of guarding doors. Stainless steel housing for high hygiene demands in the food industry are available. Based on reed technology
More informationContents. Volume 8 Sensing Solutions CA E February
Limit Switches.2 Product Description The E47 Compact Prewired Limit Switch by Eaton s electrical sector is designed to be a versatile, slim device for hard to fit applications where sealing integrity is
More informationSafety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2
Key Interlock Switch Door-Flap Switch Door-Hinge Switch.0 Introduction Technical Reference............................................ 2.1 Learn Online Product Description.............................................
More informationTongue Switches Trojan 5 & 6
Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key
More informationNon-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding
Interlock SensaGuard Non-Contact 440N RFID unique (high) or standard (low) coded actuators PLe Cat 4 per ISO 3849- (safety performance is maintained when connected in series) Flat pack and barrel (plastic
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12
More informationDatasheet - BNS ZG-ST
22.08.2014-04:52:01h Datasheet - BNS 300-01ZG-ST Safety sensors / BNS 300 Preferred typ thermoplastic enclosure Long life no mechanical wear Ø M30 Suitable for food processing industry Insensitive to transverse
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationE-STOP relays, safety gate monitors
E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button
More informationD2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.
Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European
More informationInterlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches
HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationDPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2
Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering
More informationSALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT
SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE
More informationSwitching Power Supply
Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input
More informationBNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS
BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationDevices raised mounting
Devices raised mounting Illuminated actuator pushbutton Front protection Switching system Ø 29 mm Contacts Typ-Nr. e Illuminated actuator pushbutton IP 67 LL 1 NC - MA UT 14-476.36 1 4 17 12.15 M UT 14-436.36
More informationDevices raised mounting
Devices raised mounting Illuminated pushbutton actuator Illuminated pushbutton actuator Front protection Switching system Contacts Diode (1N 47) Switching action Terminals b 18 x 18 mm Typ-Nr. a 18 x 24
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 2 auxiliary contacts (N/C),
More informationDatasheet - SLB 200-C04-1R
14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety
More informationContact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect
V Miniature Snap Action Switch Industry standard design with 10/15 Amp ratings Long mechanical life of 50,000,000 operations minimum Available in either thermoplastic or thermosetting resin Can be used
More informationGeneral-Purpose Photoelectric Sensor
General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More informationMSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR
Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 5 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection
More informationSafety Relay Unit (I/O Unit Type)
Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and
More informationTecnología en Electrónica y Control SRL Ficha Técnica
Tecnología en Electrónica y Control SRL Ficha Técnica Relé de seguridad Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas
More informationDatasheet - SRB 301LC/B-24V
27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit
More informationMiniSafe MS4600 MS4600. safety light curtains. Description
Rev. 11.07 MS4600 C US File No. LR90200 C R US escription MiniSafe MS4600 Resolution: 14 mm (0.55 in.), 19 mm (0.75 in.) or 30 mm (1.18 in.) resolution Range: 7.5 m (25 ft.) range for the 14 mm resolution
More informationE-STOP relays, safety gate monitors
Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel 1/2 Supply voltage See
More informationTemperature Controller E5C4
Temperature Controller 1/16 DIN Sized, Digital-Set Controller Features Easy-to-Read LED Display Proportional-derivative (PD) control or ON/OFF control models Front panel offset adjustment on PD controllers
More informationNot recommended for use in applications where there is high probability for exposure to liquid (e.g., cutting fluid) on the sensing surface area.
Bulletin Z Product Overview Bulletin Z Bulletin Z Zero-Force Touch Buttons are ideally suited for use in two-hand machine control systems and highly repetitive applications. Ergonomic Design The contour
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationPS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.
Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized
More informationDatasheet - MZM 100 B ST2-1P2PW2RE-A
19.03.2014-11:42:51h Datasheet - MZM 100 B ST2-1P2PW2RE-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationDatasheet - BNS ZG
21.08.2012-08:43:46h Datasheet - BNS 250-11ZG Safety sensors / BNS 250 Preferred typ LED version thermoplastic enclosure Small body Concealed mounting possible 33 mm x 25 mm x 13 mm Long life no mechanical
More informationElectronic monitoring relays PMDsrange
Unit features Altdaten CMT For DC and AC supplies Normally energised mode Fault latching or automatic reset Normal/test mode External reset button can be connected Description The insulation monitoring
More information3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard
Safety General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, ockwell Automation knows that protection of personnel and equipment is your main concern. At the same
More informationPage Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W
Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationMiniature Inductive Prox TL-W
Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationSECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i
SECTION 16 VIPER Safety Relays Type: SCR-i (with added diagnostics) SAFETY RELAY FUNCTION: IDEM s VIPER SCR-i range of Safety Relays have been designed in accordance with EN60204-1 for safety circuits
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationContact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect
VX Miniature Snap Action Switch Compact snap action switch with low force operation Internal mechanism assures outstanding contact reliability Models available for micro load up through 5 Amps ROHS Compliant
More informationMachine Safety. Products
January 23 Vol. 2, Ref. No. [1263] -1 Machine Safety Products Contents Description Page............................................. -2 Key Interlock Switches DIN Models.............................. -9
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationDatasheet - MZM 100 B ST-1P2PW2REM-A
19.07.2016-15:57:28h Datasheet - MZM 100 B ST-1P2PW2REM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationV REG.-Nr. 3919, Z E214024
General Purpose Relays SCHRACK Miniature Power PCB Relay MSR 1 pole 8 / 10 A, 1CO or 1NO contact High inrush currents with AgSnO contacts (TV4 = 65 A) 4 kv/8 mm coil-contact Reinforced insulation (protection
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More information02/11/2015
DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching
More informationonlinecomponents.com
R General-Purpose Fiber-optic Sensor Compact Limit Switch Style with Universal Supply H FET output allows for solid state switching of AC or DC H Universal AC/DC power supply H Choose cable or connector
More informationTechnical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n
Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic
More informationMain contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationClassification Enclosure rating Input voltage Type of
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.
More informationSpecifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts
Safety TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated
More informationSpecifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min
TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and
More informationTechnical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):
Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic
More informationSwitching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply
Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved
More informationCoded Non-Contact Safety Sensor Eden OSSD
Coded Non-Contact Safety Sensor Eden OSSD Approvals: Application: Door and hatches Position control Sector detection Features: Non-contact detection, 0-15 mm OSSD outputs and inputs for serial connection
More informationDatasheet - AZM300Z-ST-1P2P-A
08.04.2015-16:04:56h Datasheet - AZM300Z-ST-1P2P-A Solenoid interlock / AZM300 Suitable for mounting to profile systems Thermoplastic enclosure 3 different directions of actuation Compact design 3 LEDs
More informationThe SMART Non-contact Safety Sensor SRF With an innovative diagnostic system
The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More information802B Compact, Precision and Small Precision
02B Compact, Precision and Small Precision Compact Precision Small Precision Description Bulletin 02B consists of different body styles: compact, precision and small precision. Each style has been designed
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationPlastic Cylindrical Inductive Prox
Plastic Cylindrical Inductive Prox Short Length, Shielded Sensors With Threaded Plastic Body Rugged, watertight plastic housing offers good chemical resistance and withstands washdown Wide operating voltages:
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital
More information