XLR3-11C (female) NK27-21C-R (female) + NK-AD1-R (barrel extension) NK27-22C-R (male) + NK-AD1-R (barrel extension)
|
|
- Clare Rich
- 5 years ago
- Views:
Transcription
1 Overview Snake Trunk System Example Junction Box Fantail Cable Reel Snake Junction box 6JF PA mixer Snake trunk 6C0-E Junction box 6JF input <Stage> output Connectors used with Canare multiannel cable system Cable mount Panel mount Cable mount Panel mount XLR-C For multiannel cable For Junction box For multiannel cable For Junction box Plug Receptacle Plug Receptacle NK7-C-R NK-AD-R NK7-C-R NK-AD-R D/MS06BA-0S EB-0 D/MS057-0A (cable clamp) 8 4 XLR-F77 XLR-C XLR-F77 NK7-S-R NK7-S-R D/MS0AA-0P FK7-C-R FK-AD-R FK7-C-R FK-AD-R D/MS06B6-7S EB-0 D/MS057-4A (cable clamp) 6 FK7-S-R FK7-S-R D/MS0A6-7P Tenical Trend Fiber-Optic Systems Connectors Cables Panels & Patbays Mutiannel Systems Cable Assemblies 8
2 Snake Trunks, Cable Reel Snakes L-4E Star quad, Braided shield Snake Trunks M Two-cord, AT shield Cable Reel Snakes 8 connector : NK7-C /4-R, NK7-C /4-R cable : L-4E-8P (black) rubber bushing : AN40- Heat Shrink Tube 8C05-E 5m.6kg 8C0-E 0m.0kg 8C0-E 0m 8.4kg 8C50-E 50m.8kg connector : NK7-C /4-R, NK7-C /4-R cable : M0-8AT (black) rubber bushing : AN40-0, Heat Shrink Tube 8C0-M 0m.7kg 8C0-M 0m 4.5kg 8C50-M 50m 7.kg connector : NK7-C-/4-R cable : L-4E-8P (black) Cable reel 8R0-E 0m 8.kg R80 8R50-E 50m.0kg R80 connector : NK7-C 7/8-R, NK7-C 7/8-R cable : L-4E-P (black) rubber bushing : AN40-6 C05-E 5m.kg C0-E 0m.9kg C0-E 0m.kg C50-E 50m 8.kg connector : NK7-C /4-R, NK7-C /4-R cable : M0-AT (black) rubber bushing : AN40-0, Heat Shrink Tube C0-M 0m.kg C0-M 0m 5.8kg C50-M 50m 9.kg connector : NK7-C-7/8-R cable : L-4E-P (black) Cable reel R0-E 0m 0.6kg R80 R50-E 50m 0.4kg R460 6 connector : FK7-C 7/8-R, FK7-C 7/8-R cable : L-4E-6P (black) rubber bushing : AN40-6 6C05-E 5m.6kg 6C0-E 0m 4.9kg 6C0-E 0m 4.kg 6C50-E 50m.kg connector : FK7-C 7/8-R, FK7-C 7/8-R cable : M0-6AT (black) rubber bushing : AN40-0,, 6 6C0-M 0m.7kg 6C0-M 0m 7.5kg 6C50-M 50m.kg connector : FK7-C-7/8-R cable : L-4E-6P (black) Cable reel 6R0-E 0m 4.kg R80 6R50-E 50m 6.kg R460 4 connector : <D/MS06B-A0SD/MS057-0A> cable : L-4E-4P (black) rubber bushing : AN40-0 4C05-E 5m 4.kg 4C0-E 0m 7.7kg 4C0-E 0m.7kg 4C50-E 50m 5.7kg Extension Cord <D/MS0AA0PD/MS057-0A>X Cable:L-4E-4P (black) 4C005-EMS connector : <D/MS06B-A0SD/MS057-0A> cable : M0-4AT (black) rubber bushing : AN40-6, 0 Heat Shrink Tube 4C0-M 0m 4.0kg 4C0-M 0m 0.4kg 4C50-M 50m 6.8kg connector : D/MS06B-A0S cable : L-4E-4P (black) Cable reel 4R0-E 0m 4.6kg R460 connector : <D/MS06B6-7SD/MS057-4A> cable : M0-AT (black) rubber bushing : AN40-6, 0, 4 C0-M 0m 4.8kg C0-M 0m.kg C50-M 50m.0kg Extension Cord connector : <D/MS0A6-7PD/MS057-4A> cable : M0-AT (black) C005-MMS Note: Connecting cables 4C005-EMS and C005-MMS are to be used to interconnect snake trunks only and they do not mate with our other standard snake system. : Female : Male 8
3 Fantails, Junction Boxes Fantails Junction Boxes 8SN Connector : XLR-C x8, NK7-C-/4-R Cable : L-4E6S (black).5m Weight :.kg 8SN Connector : XLR-C x8, NK7-C-/4-R Cable : L-4E6S (black).5m Weight :.0kg SN Connector : XLR-C x, NK7-C-/4-R Weight :.4kg SN Connector : XLR-C x, NK7-C-/4-R Weight :.kg 6SF Connector : XLR-C x6, FK7-C-7/8-R Weight :.9kg 6SF Connector : XLR-C x6, FK7-C-7/8-R Weight :.7kg 4SMS Connector : XLR-C x4, D/MS0A-A-0P Cable : L-4E5C (black) 4SMS Connector : XLR-C x4, D/MS0A-A-0P Cable : L-4E5C (black) SMS Connector : XLR-C x, D/MS0A-6-7P Cable : L-4E5C (black) SMS Connector : XLR-C x, D/MS0A-6-7P Cable : L-4E5C (black) Single XLR per annel 8BN Connector: XLR-F77 x8, NK7-S-R x Weight : 0.9kg 8BN Connector: XLR-F77 x8, NK7-S-R x Weight :.kg BN Connector: XLR-F77 x, NK7-S-R x Weight :.kg BN Connector: XLR-F77 x, NK7-S-R x Weight :.kg 6BF Connector: XLR-F77 x6, FK7-S-R x Weight :.6kg 6BF Connector: XLR-F77 x6, FK7-S-R x Weight :.kg Parallel XLR per annel 8JN Connector: XLR-F77 x8, XLR-F77 x8 NK7-S-R x Weight :.5kg 8JN Connector: XLR-F77 x8, XLR-F77 x8 NK7-S-R x Weight :.5kg JN Connector: XLR-F77 x, XLR-F77 x NK7-S-R x Weight :.kg JN Connector: XLR-F77 x, XLR-F77 x NK7-S-R x Weight :.kg 6JF Connector: XLR-F77 x6, XLR-F77 x6 FK7-S-R x Weight :.5kg 6JF Connector: XLR-F77 x6, XLR-F77 x6 FK7-S-R x Weight :.5kg 4BMS Connector: XLR-F77 x4 (on top) XLR-F77 x4 ( on ea side) D/MS0A-A0P Weight :.7kg BMS Connector: XLR-F77 x, XLR-F77 x D/MS0A6-7P Weight : 5.kg BMWF Connector: XLR-F77 x, XLR-F77 x D/MS0A6-7P x, FK7-S-R x Weight : 6.0kg Parallel XLR per annel MultiPin feed through 8JN Connector: XLR-F77 x8, XLR-F77 x8 NK7-S-R x, NK7-S-R x Weight :.6kg JN Connector: XLR-F77 x, XLR-F77 x NK7-S-R x, NK7-S-R x Weight :.kg 6JF Connector: XLR-F77 x6, XLR-F77 x6 FK7-S-R x, FK7-S-R x Weight :.6kg 4BMSW Connector: XLR-F77 x4 (on top) XLR-F77 x4 ( on ea side) D/MS0A-A0P x Weight :.0kg BMSW Connector: XLR-F77 x, XLR-F77 x D/MS0A6-7P x Weight : 5.5kg BMF Connector: XLR-F77 x, XLR-F77 x D/MS0A6-7P x, FK7-S-R x Weight : 5.7kg Tenical Trend Fiber-Optic Systems Connectors Cables Panels & Patbays Mutiannel Systems Cable Assemblies 8
4 Pin Assignments Multiannel Connector Pin Assignments Ch No. Cable Unit Identification / L-4E M0 D/MS0A6-7 D/MS0AA-0 FK7 NK7 Spiral Insulator Color D/MS06B6-7 D/MS06BA-0 Marker Identifying identifying Common Color Color HOT COLD HOT COLD HOT COLD HOT COLD Color RED RED WHT A B A B BLU BLU C D C D YEL YEL F H F G GRN GRN J K H J BRN BRN L M K L 0 6 N/A GRY N P N O 4 7 BLU BLK BLU BLK R S P R YEL BLK YEL T U S T GRN BLK GRN V W U V BRN BLK BRN Y Z X Y 4 BLK GRY a b Z a BLU ORN BLU ORN c d b c YEL ORN YEL f g d e 9 0 SHIELD 4 GRN ORN GRN h i g h 0 5 BRN ORN BRN j k j k ORN GRY m n m n BLU PNK BLU PNK u v p q SHIELD 8 YEL PNK YEL w x s t 9 9 GRN PNK GRN y z u v 0 BRN PNK BRN AA AB w x PNK GRY AC AD AB z BLU WHT BLU RED AE AF AA AC YEL WHT YEL AH AJ AD AF 4 GRN WHT GRN AL AM AG AE 5 BRN AN AP SHIELD 6 GRY AR AS E 7 YEL BLU AT AU 8 GRN AV AW 9 BRN AX AY 0 GRN YEL AZ BA BRN BC BD GRY BE BF SHIELD E q t X r AK p s BB Connection Method A B D E F H C J K L M N P R S T U V W X Y Z a b c d f g h i j k m n p q r s t u v w x y z AA AB AC AD AE AF AH AJ AK AL AM AN AP AR AS AT AU AV AW AX AY AZ BA BB BC BD BE BF S b m A B C D E F G H J K L M N O P R T U V X Y Z a c d e g h j k n p q s t u v w x y AB z AA AC AD AF AG AE L-4E Types: Identify the annel number by the color of the spiral marker on the inner jacket (gray). The unit is 4-core construction and the insulator colors are blue, blue, white, and white. Connect these with the same colored cores, so that the blue cores are connected to Hot and the white cores to Cold. M0 Types: The unit is -core construction, with the annel number identified by the insulator color (a combination of the identifying color and common identifying color). Connect the identifying color core to Hot, and the common identifying color core to Cold. Connections to XLR Connectors Polarity HOT COLD SHIELD Pin No. W f r 84
5 Reels Cable Reels Plain reels for winding cable Model Weight (kg) Description Stackability R460-S 9.9 Reel unit for cable winding / With caster. N/A R80-S 8. Reel unit for cable winding / With caster. N/A R00-S 4. Reel unit for cable winding. R00 4. Front panel can be refurbished to create connector mounting holes. R00-L 4. Both front panel and drum can be refurbished to create connector mounting holes. R00-CN 4. Both panel and drum have XLR connectors (one male, one female) installed. R00-BN 4. Both panel and drum have BNC receptacles (one ea). -speed brake controller. (Lock/Soft/Free) Non-lubricated bearings. Rugged E frame design. Wiring XLR--F77 ORG WHT XLR--F77 L-BAT R00-CN XLR--F77 ORG WHT XLR--F77 Reel with Cable Assembly Cable detaable type. BCJ-JRUK BCP-A L-CVS R00-BN BCP-LC Description Weight Model Cable Cable Assemblies (kg) reel Inner end Cable Outer end XLR-C L-4E6S(00m) XLR-C CR00-CN R00-CN 9.6 XLR-C L-4E6S(00m) XLR-C CR00-S R00-S 9.6 BCP-H5B L-5CVS(90m) BCP-H5B CR90-BN R00-BN 0.5 Dimensions R460-S R80-S R00-S BCJ-JRUK R00 ( Connectors can be attaed to the front panel ) R00-L ( Connectors can be attaed to the front panel and the drum ) R00-CN (R00-BN comes with BNC receptacles) -speed brake controller R460-S R00-S Cable winding length reference art <Wind length conversion formula> CR00-CN R00-S L= 8448 x 0.6 (m) R460-S L= 85 x 0.6 (m) (S, L, CN) D D R80-S L= 807 x 0.6 (m) D D: cable outer diameter (mm) L: wind length Tenical Trend Fiber-Optic Systems Connectors Cables Panels & Patbays Mutiannel Systems Cable Assemblies 85
SPARE CONNECTORS KTM 2014
SPAREPARTSCATALOG: // ENGINE ART.-NR.: 3208201EN CONTENT CONNECTORS FOR WIRING HARNESS AA-AN CONNECTORS FOR WIRING HARNESS AO-BC CONNECTORS FOR WIRING HARNESS BD-BQ CONNECTORS FOR WIRING HARNESS BR-CD
More informationDETAIL SPECIFICATION SHEET
INCH-POUND MIL-DTL-55302/128D 18 April 2013 SUPERSEDING MIL-DTL-55302/128D 4 June 2004 DETAIL SPECIFICATION SHEET CONNECTORS, PRINTED CIRCUIT SUBASSEMBLY AND ACCESSORIES: RECEPTACLE, DOUBLE ROW, 4 THROUGH
More informationSPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN
SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS
More information22ND CENTURY_J1.xls Government Site Hourly Rate
Escalation rate 000 AA0 Administrative Assistant Level I 000 AA0 Administrative Assistant Level II 000 AB0 Application Engineer Level I 000 AB0 Application Engineer Level II 000 AC0 Application Programmer
More informationAppendix 5-1: Attachment J.1 Pricing Table -1: IMS Ceiling Loaded Rates at Contractor Site
Appendix 5-1: Attachment J.1 Pricing Table -1: IMS Ceiling Loaded Rates at Contractor Site Escalation rate 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 0001 AA01 Administrative Assistant Level I $51.00
More informationWorking with Data sent to a Computer or Flash Stick
Working with Data sent to a Computer or Flash Stick File Names and File Formats Data sent to a flash stick is saved as a.txt file. The file name for the saved file is in the format: DATA FILE TYPE Send
More informationParts List, Charging Chart, Wiring Diagrams
Parts List, Charging Chart, Wiring Diagrams PHH150, PHH180 3 Phase PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST------------ 2-5 PARTS DRAWING - - - - - - -6-16 CHARGING CHARTS - - - - - - - 17
More informationParts List, Wiring Diagrams
Parts List, Wiring Diagrams PAH 210-300 SERIES 3 Phase PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST --------------2-5 PARTS DRAWINGS ------ 6-22 CHARGING CHARTS ---- 23-25 WIRING DIAGRAMS
More informationOPAL-RT FIU User Guide.
OPAL-RT FIU User Guide www.opal-rt.com Published by Opal-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2013 Opal-RT Technologies, Inc. All rights reserved
More informationPRG FIBER OPTIC SYSTEMS
WWW.PRG.COM PRG FIBER OPTIC SYSTEMS USER MANUAL AutoPar, Bad Boy, Best Boy, MBOX, Nocturne, PRG Series 400, V476, V676, and Virtuoso are trademarks of Production Resource Group, LLC, registered in the
More informationParts List, Charging Chart, Wiring Diagrams
Parts List, Charging Chart, Wiring Diagrams PHD3 30-60 SERIES 3 Phase R-410A PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST 2-8 PARTS DRAWING 9-22 CHARGING CHART 23 WIRING DIAGRAM 24-27 Printed in
More informationSpecification for SN Transceiver Receptacle Rev 1.0 Feburary 12 th, 2019
Specification for SN Transceiver Receptacle Rev 1.0 Feburary 12 th, 2019 Abstract: This specification defines the fiber optic connector interface, a single position plug connector set of plug/adapter configuration
More informationOperating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High
Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical
More informationATP SERIES ATP Series
ATP SERIES ATP Series 87 ATP Series Overview ATP Series connectors are designed as a high-performance, cost-effective, thermoplastic solution to be used within the Marine, Heavy Equipment, Agricultural,
More information(db)
75Ω Video Patchbays 75Ω Video Patchbays G-ready HD-SDI video patchbays featuring Canare s uniquely-developed rotary switches. Panel Size Loaded Video Jacks 2DV 1 U 2 x 2DVS 1 U 2 x DVJB-S 2DV-2U 2 U 2
More information1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7
1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7 C H A P T E R F I V E WIRING WARNING: Failure to reconnect ground wires or replace metal shields may result in radio frequency interference. NOTICE:
More information*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories
*00* 00 Senior Swing Control Box 00, 900 Series Retrofit Instructions Retrofit Cables = = WHT = = NO WIRE -00 0V POWER CONNECTION Cable AC Power = = YEL = WHT/ = RED = = WHT/RED Cable Motor Power = =YEL
More informationParts List, Charging Chart, Wiring Diagrams
Parts List, Charging Chart, Wiring Diagrams PAH036-072 SERIES Three Phase PACKAGE A/C UNITS TABLE OF CONTENTS PARTS LIST---------- 2-7 PARTS DRAWING - - - - - 8-14 CHARGING CHARTS - - 15-16 WIRING DIAGRAMS
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationSIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information
SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information General amendments to the documentation Contents This product information includes amendments
More information2-Type Series Pressurized Closures
2-Type Series Pressurized Closures A complete pressure tight reenterable closure system for enclosing spliced connections of communications cables in a wide variety of applications. The 2-type Closure
More informationSIMATIC S plus TIA Portal
Product range overview SIMATIC S7-1500 plus TIA Portal Power + Efficiency The ultimate plus in automation Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry. Your plus of
More information2 [1] OVEN S 2-6 2-7 7-19 7-8 1-12 1-12 4-18-3 4-18-1 4-18-2 4-18 4-24 4-26 4-28 4-28 4-31 2-1 2-1-2 2-1-1 7-20 2-5 2-6 2-7 2-4 4-40 4-23 7-8 7-3 7-3 7-10 7-10 1-24 1-4 1-19 1-14 1-14 1-21 1-21 7-9 7-1
More informationSRH. SRH Standard Through-Bore Slip Ring. Industrial Slip Rings. Features. Options. Typical Application. The Leading Slip Ring Manufacturer 17
SRH SRH Standard Through-Bore Slip Ring Features Continuous transmission of power and/or signal under 0 unrestrained rotation Applies advanced fiber brush technology, free of maintenance or lubricating
More informationMOUNTING STYLE. A - Axial (end) R - Radial (side) See Chart Below CONNECTOR CHANNEL A, B, C, D, R, T, U, 2, 3, 7, W E, F, G, H, J, K, M, N B, E 5 E
Encoder Instructions VTRON ENCODERS Nidec Industrial Solutions Makes the Most Reliable Encoders in the World 8901 E. PLEASANT VALLEY ROAD INDEPENDENCE, OHIO 44131-5508 TELEPHONE: (1) 216-642-1230 FAX:
More informationHorizon HX Wiring Supplement
Horizon HX Wiring Supplement Revision A3-8/2/2016 For units shipped after January 8, 2013 Applies to single or multi-display systems with single or dual AHRS and the following Wiring Harness Part Numbers:
More informationParts List, Charging Chart, Wiring Diagrams
Parts List, Charging Chart, Wiring Diagrams PHH036-072, 3 Phase PACKAGE HEAT PUMPS TABLE OF CONTENTS PARTS LIST---------- 2-4 PARTS DRAWING----- 5-10 CHARGING CHARTS-- 11-12 WIRING DIAGRAMS-- 13-24 Printed
More informationPIN CONTACT MATING FACE
Differential Twinax Contacts General Description AMPHENOL DIFFERENTIAL TWINAX CONTACTS Offer several advantages for high data transfer rates, low power consumption and excellent EMI compatibility: Two
More informationCabling a Data Center to TIA-942 Standard
Cabling a Data Center to TIA-942 Standard BICSI 2006 Winter Conference Wednesday, January 25 th 2006 at 9:15 am Gary J. Bernstein, RCDD HellermannTyton Corporation Agenda Overview of TIA-942 Data Center
More informationATM SERIES ATM Series
SERIES Series CONNECTOR SOLUTIONS 21 Series Overview Series connectors are a high-performance, cost-effective solution specifically designed for smaller AWG applications, while still maintaining the strengths
More informationDigital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack
Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems,
More informationPN - Compact Angular Gripper
Double acting High efficiency and reliability due to few moving parts Two or three jaws Optional magnetic sensors available. #6256 #6254 #6352 #6250 #6257 #6255 #6253 #6251 Fittings Available on page 935
More informationPosi-Lok Plugs and Panels
THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA
More informationBlue Point Engineering
DMX -Ch Switch Board Overview he DMX video switcher board will switch up to composite video input signals to a single video output channel under user control. he board requires a single DMX channel and
More informationUser Guide for OSM users to Record Youth Data on the TSA Template to be Used for Uploading Youth Data to Compass
User Guide for OSM users to Record Youth Data on the TSA Template to be Used for Uploading Youth Data to Compass This is a user guide for OSM users on how to copy youth data exported from OSM into the
More informationC-SMART Help: Monetary Contributions 3/4/2019 Page 1
C-SMART Help: Monetary Contributions 3/4/2019 Page 1 C-SMART HELP IMPORT CONTRIBUTIONS C-SMART allows you to import contributor information if it is formatted as a comma-separated values (CSV) file, which
More informationPARTS LIST AX-1200K AX-1200S MODELS SUPER STEAM OVEN CONTENTS
PartsGuide S LIST AX1200K MODELS SUPER STEAM OVEN AX-1200K AX-1200S Parts marked "*" may cause undue microwave exposure. Parts marked " " are used in voltage more than 250V. CONTENTS [1] OVEN S [2] CABINET
More informationDigital Lighting Systems, Inc.
Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical
More informationAQS (Air Quality System) General Overview
AQS (Air Quality System) General Overview CARB PQAO Training January 25, 2017 Jennifer Williams EPA Region 9 1 AQS (Air Quality System) Overview What is AQS? Database that contains: Ambient air pollution
More informationThis connector has been added along with the signals needed by the REEL SAFE system
MODIFICATION TO AMS4A046 PANEL Modification adds the following three features: 1. CCL Detector and depth display The panel will now detect and display the depth where a collar was detected. The CCL signal
More informationExcerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act
SIRIUS ACT Core spectrum selection guide Excerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act SIRIUS ACT commanding and signaling SIRIUS ACT modern, high-performance
More informationSN Series - Part Numbering
SN Series - Part Numbering Features Push-pull technology Miniature circular Light weight Low cost Applications Professional audio and video CCTV system Portable wireless radio Factory Automation Computers
More informationDigital Lighting Systems, Inc.
, Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual
More informationhttps://support.industry.siemens.com/cs/ww/en/view/
Support Packages for TIA Portal V13 March 2018 https://support.industry.siemens.com/cs/ww/en/view/72341852 Siemens Industry Online Support This entry is from the Siemens Industry Online Support. The general
More informationINTERCOM SYSTEM Model ICA900
Document Number: XE-ICA9PM-R0A ICA900 Rev150324 INTERCOM SYSTEM Model ICA900 Push-To-Talk Control Module Speaker Box Hands Free Control Module FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern
More informationEASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations
EASTERN LABS Instructions Model RM-1205 04/25/2007 Operation Junction Box Assembly Different Types of Switch Installations Counter Mounting Suggestions Operation Total Counter Mix Counter Thru counter
More information35S-1 HB 3 HB 2 35S-1. Mounting style. Basic style. Standard type. Switch Set. Type. Nominal pressure Maximum allowable pressure Proof test pressure
f f f f f f Type Nominal pressure Maximum allowable pressure Proof test pressure Minimum operating pressure Working speed range Standard type. MPa 4 MPa MPa Switch Set fff. MPa.1 MPa to mm/s Working temperature
More informationCIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. NOTE: Router E should only be used for Internet traffic. Router A Router
More informationTerminal Junction System (MIL-T and Commercial)
Introduction Product Facts The TJS connections are inherently more reliable than conventional threaded and solder terminations. The user s wiring is crimped to gold plated pin contacts, conforming the
More informationDigital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module
, Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION
More informationCONNECTORS & RECEPTACLES
TINI Q-G MINIATURE CONNECTORS DESIGN FEATURES STYLE Streamlined, miniaturized with nickel-plated metal and contrasting black plastic parts. Designed for light weight and unobtrusiveness. Also available
More informationA. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA NSM5200 SERIES NETWORK STORAGE MANAGER TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1_28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2_28 23 00 VIDEO SURVEILLANCE
More informationModular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308
Modular Splicing Modular Splicing Kits 305 Cable Adapter Kits 308 MODULAR SPLICING 3M Modular Splice Kits form a 5 to 25 kv 600 Amp separable insulated connector system. The system is easy to expand and
More information2015 ECA TELECOM OPTIONS REVIEW
2015 ECA TELECOM OPTIONS REVIEW INTRODUCTION WHAT ARE TELECOM PLATES: 3.18 ECA Telecom Plates are proprietary and designed to fit into any ECA power solution that includes a telecom plate cutout. Each
More informationDOI: / Eng
(/ ) - : : DOI: 10.4197 / Eng. 21-2.9 - - :. anoaman@kau.edu.sa mhmd@hashimi.info..... ١٦٩ ١٧٠.. [ - ]. [ - ]... - ١٧١... :........ - -.. ١٧٢ - - - (computing) [ ]. ( ).... :...... - - - ١٧٣..... ( ) )
More information(120V) (100V / OBSOLETE)
Aquamatic Selectric PARTS LIST Advance MODELS 0(0V) 0(00V / OBSOLETE) This parts list is for machines after serial number 0 / revised /0 Form Number 0 revised /00 FORM NO. 0 TABLE OF CONTENTS DESCRIPTION
More informationSIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information
SIMATIC Digital Input Module Product information 1 SIMATIC Digital Input Module Product Information This documentation is part of the documentation package with the order number: S7-300 Automation System:
More informationPN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit
CAUTION: Please make sure you have or have access to the skills necessary to assemble and use this product. Always secure the case with the included screws before applying electrical power to the power
More informationIntroduction This manual presents an overview of the Assembly and Test Cost and Price Model and the basic workings of the model.
Packaging Cost and Price Model User Manual IC Knowledge LLC, PO Box 20, Georgetown, MA 01833 Tx: (978) 352 7610, Fx: (978) 352 3870, email: info@icknowledge.com Version 2019 model Introduction This manual
More informationProfessional Studio Headphones WH4500 (Page 116) Connectors: Standard Wire Gauge: 22AWG Wire: Copper Warranty: Limited lifetime
Audio CABLES Professional Studio Headphones Instrument Cables Instrument Cables Pro Neutrik Microphone Cables Wire Gauge: 20AWG Shielding: Tinned copper braiding Shielding: Spiral copper IC-10 / 10797
More informationPackaging Solutions. Advanced Packaging Solutions for High-Density PLDs
Packaging Solutions Advanced Packaging Solutions for High-Density PLDs June 1998 package options pin compatibility design flexibility Advanced Packaging Solutions FineLine BGA vertical migration space
More informationNT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack
The NT1-220 Rack is designed to be used in conjunction with Tone Commander NT1U-220TC ISDN Network Terminations. A maximum of twelve NT1 units can be used in each rack. NT1-220 Rack Installation Instructions
More informationSIMATIC ET 200SP. siemens.com/et200sp. Simple to use, smaller in size, stronger in performance. Answers for industry. Engineered with TIA Portal
Engineered with TIA Portal siemens.com/et200sp SIMATIC ET 200SP Simple to use, smaller in size, stronger in performance Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry.
More informationProximity sensors, block design
Proximity sensors, block design Proximity sensors, block design Product range overview Measuring principle Version Type Mounting Switching element function Switching Electrical connection N/O contact N/C
More informationMCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013
1. Table of Contents 1. Table of Contents Page 1 2. Remove Failed MCH-103.2 Page 1 3. Install MCH-103.2 to MCH-102NW Page 2 4. Install NC3FX-HD to MCH-103.2 Page 3 5. Install MCH-103.2 Battery Terminal
More informationTechnical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988
www.gkinc.com support@gkinc.com Technical Practice Contents Section 1 General Description Section 2 Applications Section 3 Installation Section 4 Circuit Description Section 5 Specifications Section 6
More informationCIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1
Version 1 Instructions Write your name on the exam paper. Write your name and version number on the top of the yellow paper. Answer Question 1 on the exam paper. Answer Questions 2-4 on the yellow paper.
More informationConnecting MicroE Optira Series Encoder to AMC DigiFlex Servo Drive
TECHNICAL NOTES: INTERFACING WITH DRIVES Connecting MicroE Optira Series Encoder to AMC DigiFlex Servo Drive TN-1304 REV 151214 1 Introduction... 3 2 Required items... 4 2.1 Optira... 4 2.2 Optira Development
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationhttps://support.industry.siemens.com/cs/ww/en/view/
Which Frame Colors are Used for the SIMATIC Operating Units and SIMATIC IPCs? HMI Operating Units, IPCs, Industry Monitors, Industrial Thin Clients https://support.industry.siemens.com/cs/ww/en/view/85050
More informationETC Installation Guide
ETC Installation Guide Desire Series D22 Introduction ETC s Desire D22 is designed for indoor installations and has a rugged die-cast enclosure, steel mounting yoke, and noise-free, fan-less operation.
More informationW52P1J-15-D-0060 [ ] Honeywell CN70GQ5KN00G1A40
AMIS AIT-V Contract Products Snapshot This AIT-V Contract Products Snapshot is an abbreviated presentation of the product offerings by the three contractors providing their products and services. All CLINS
More informationA. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA EE500 SERIES ENDURAXPRESS TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1_28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2_28 23 00 VIDEO SURVEILLANCE LEVEL 3_28
More informationCable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles)
CABLE ASSEMBLY TYPES Quantity - Please use one request form per cable assembly type End A Cable assembly types End B Patch cord Receptacle Gas tight receptacle L b Breakout L b Single Fiber Drawings are
More informationRound Water-resistant Connectors (M12) XS2
Round Water-resistant Connectors (M) XS Water- and Environment-resistive FA Connectors Save Wiring and Maintenance Effort Compact FA connectors satisfy IP67 requirements and ensure a 9V-0 fire retardant
More informationProduct information Patch Cord Cat. 5e, SF/UTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 0.5 m
Product information Patch Cord, SF/UTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 0.5 m R305039 101347005 10 Pcs. Cable identification: SF/UTP Outer jacket: LSFRZH Conductor diameter copper strand: AWG 26/7 Screened
More informationConnector System for Circular Contacts
Connector System for Circular Contacts Introduction The diameter 1.5 mm and diameter 2.5 mm Connector System is designed for electronic and electrical applications in motor vehicles. It fullfils all requirements
More informationNT1B-300 Rack Installation Instructions
The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies
More information(db)
75 Video Patchbays 75 Video Patchbays 3G-ready HD-SDI video patchbays featuring Canare s uniquely-developed rotary switches. Panel Size Loaded Video Jacks 2DV 1 U 2 x 2DVS 1 U 2 x DVJB-S 2DV-2U 2 U 2 x
More informationRIO BRAVO IP ENGINE OVERVIEW
CD - - - -6 CD - - - -6 CD - - - -6 SA S SA S SA S - - - -6 - - - -6 - - - -6 TO OL S - - - - 6 TO OL S - - - - 6 TO OL S - - - - 6 - - - -6 TRAFF TRAFF - - - -6 TRAFF - - - -6 CD - - - -6 CD - - - -6
More informationATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard
More informationSIMATIC S Central processing units
SIMATIC S7-1500 Siemens AG 2013 Overview CPU 1511-1 PN PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under
More informationRS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out.
RS 232 PINOUTS 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out. 2. A DB9 Female to RJ12 Female Serial/Terminal Modular Adaptor
More informationFISCHER MINIMAX TM SERIES
TECHNICAL SPECIFICATIONS FISCHER TM SERIES Fischer Connectors SA All rights reserved Web version 1.0-03.2016 Changes without prior notice FISCHER TM SERIES KEY FEATURES The Fischer MiniMax Series increases
More informationFAQ# 940-1F091 AMCI Frequently Asked Question
FAQ# 940-F09 Frequently Asked Question Can I Use Transducers From Other Manufacturers With Controllers? When receives an inquiry about using foreign products, it is generally about transducers from one
More informationALS9A240 DEPTH BACKUP AND DRUM RIB COUNTER DISPLAY PANEL Operations and Maintenance Manual
ALS9A240 DEPTH BACKUP AND DRUM RIB COUNTER DISPLAY PANEL Operations and Maintenance Manual TABLE OF CONTENTS SECTION DESCRIPTION 1.0 GENERAL DESCRIPTION 2.0 OPERATING PROCEDURES 3.0 DESCRIPTION OF FEATURES
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1360754 (082270) Master Contract: 178632 Project: 70070007 Date Issued: 2018-01-23 Issued to: Ilme S.p.A. Via Marco Antonio Colonna 9 Milan, 20149 ITALY The products
More informationCIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. Router A Router B Router C Router D Network Next Hop Next Hop Next Hop Next
More informationSM CONNECTOR. 1Certified LR R Disconnectable Crimp style wire-to-wire connectors. Features. Specifications. Standards. 2.
Crimp.mm (.") pitch SM CONNECTOR Disconnectable Crimp style wire-to-wire connectors Features High contact pressure With each insertion and withdrawal, the mating contacts wipe against each other to remove
More informationBOOK-IT 8.0. SIP2 implementation in the Z39.70 server
BOOK-IT 8.0 2015-07-29 Axiell Sverige AB, Box 24014, 224 21 LUND. Besöksadress: Fältspatsvägen 4, 224 78 LUND Tel 046-270 04 00, e-post: axiellsverige@axiell.com, www.axiell.se Table of contents 1 Introduction...
More informationCIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1
Version 1 1. (20 Points) Given the class A network address 121.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 8,100 subnets? b. (5 Points) What is
More information8WH5 Combination Plug-In Terminals
8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical
More informationInstallation Instructions
Second Kit for the GrandSTAR Jukebox Kit #26694913 Purpose: These instructions outline the procedures to install a second 1000W into the GrandSTAR jukebox with the AV controller (shown) or the 4 Channel
More informationContact resistance : environmental class hermetic class
8525 eries pplications or all general purposes in civil aeronautical applications tandards N 93422 32 NL 5413 N 1599 M T1 list LN 2954 escription Light weight version of MIL 26482 eries II Intermateable
More informationRAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL
RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL DESCRIPTION OF CONTROLS Refer to Figure 1 Figure 1 A. HOUR DIAL with 23 CYCLE START PINS The HOUR dial contains 23 pins for rescheduling automatic
More informationWaterproof Connectors with Crimp Contacts
Waterproof Connectors with Crimp s Comptatible with JIS-B-6015 CE01 Series Conforming Standard JIS B 6015 Wa t e r p r o o f IP67 Lock Type Bayonet OUTLINE CE01 series is compatible with JIS-B 6015,Japanese
More informationK2 OWNER S MANUAL ERRATA. Rev. I - 7, March 19, 2017
K2 OWNER S MANUAL ERRATA Rev. I - 7, March 19, 2017 MAKE THESE CHANGES TO YOUR REV. I MANUAL BEFORE YOU BEGIN ASSEMBLY OR ANNOTATE THE MANUAL TO REFER TO THIS ERRATA. 1. Page 20, Right Column: Under Inventory,
More informationSINGLE OR DOUBLE ACTING CYLINDERS, Ø 8 to 25 mm
SINGLE OR DOUBLE ACTING CYLINDERS, to mm CONFORMING WITH ISO 43 - CETOP - AFNOR STANDARDS ISOCLAIR - SERIES 435 - TYPES : C-AS, CC-AS P-GB-R5 ISOCLAIR AIR CYLINDERS to mm OPERATIONAL DIAGRAMS ( to mm)
More informationDynoWare EX+ Upgrade Installation Guide for Motorcycle Dynamometers.
1993-2002 Dynojet Research, Inc. All Rights Reserved. for Motorcycle Dynamometers. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This
More informationDon t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of 32G to 400G
Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of G to 00G Dave Fredricks Data Center Infrastructure Architect #DATACENTERWORLD #CPEXPO CHANNELPARTNERSCONFERENCE.COM DATACENTERWORLD.COM
More information