Product Data. 25HNA6 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons INDUSTRY LEADING FEATURES / BENEFITS

Size: px
Start display at page:

Download "Product Data. 25HNA6 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons INDUSTRY LEADING FEATURES / BENEFITS"

Transcription

1 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons the environmentally sound refrigerant Carrier s heat pumps with Puron r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HNA has been designed utilizing Carrier s Puronr refrigerant. The environmentally sound refrigerant allows consumers to make a responsible decision in the protection of the earth s ozone layer. As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. Product Data INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S New Aesthetic Design S WeatherArmor Ultrat SEER/ EER/ HSPF Baked on powder paint Steel louver coil guard Color matched cabinet screws Extra Quiet Operation S Silencert II for sound as low as 70 dba Quiet mount split post compressor grommets Quiet External Silencer muffler Exclusive Silencer Top design 8 Pole PSC ball bearing outdoor condenser fan motor Forward -swept condenser fan blade Compressor sound hood Laminated steel compressor mounting plate S Quiet Shift Defrost Reliability, Quality and Toughness S S Field -installed 16 cu. in. filter drier S Back -seating service valves S High pressure switch S Loss of charge switch S Internal pressure relief valve S Internal thermal overload S Long -line accessory connections S Suction Line Accumulator S Vapor fog eliminator S Ideal Defrost Controls and Diagnostics S Infinityt Control or Thermostat S Utility Interface Connection S Up to 23 point diagnostic capability Applications S Two -Stage reciprocating compressor Long -line - up to 250 ft. total equivalent length, see Long Line Guide for more information S Low ambient (down to 0_F) with complete Infinityt system Limited Warranty S 10 -year limited warranty on compressor S 5 -year limited warranty on all parts

2 MODEL NUMBER NOMENCLATURE N N A A A/N N N N A/N A/N A/N N N 2 5 H N A A Product Series 25=HP Product Family H=RESHP Tier n= infinity Series Major Series SEER Cooling A=Puron 6=16SEER A=Standard Variations Open Open Voltage 0=Not Defined 0=Not Defined Minor Series 3=208/ , 1, 2... ISO 9001:2000 the environmentally sound refrigerant REGISTERED As an Energy Star Partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines. STANDARD FEATURES Feature Puron Refrigerant X X X X Up to 16 SEER X Second Generation Infinityt Control or Thermostat X X X X Two Stage Reciprocating Compressor X X X X Weather Armor Ultrat X X X X Silencer IIt X X X X FieldInstalled16cu.in.FilterDrier X X X X Loss of Charge Switch X X X X High Pressure Switch X X X X Back Seating Service Valves X X X X Internal Pressure Relief Valve X X X X Internal Thermal Overload X X X X Long Line Accessory Solenoid Connections X X X X Long Line capability X X X X Low Ambient capability to 0_F --- Standard* X X X X Suction line accumulator X X X X Up to 23 Point Diagnostics X X X X Quiet Shift Defrost X X X X Vapor Fog Eliminator X X X X Ideal Defrost* X X X X Utility Interface Cconnection X X X X * With complete Infinity 2

3 PHYSICAL DATA UNIT SIZE SERIES Operating Weight (lb) Shipping Weight (lb) Compressor Type Stage Reciprocating REFRIGERANT Puron (R---410A) Control TXV (Puron Hard Shutoff) Charge (lb) COND FAN Forward Swept Blade Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) Motor HP 1/12 1/10 1/5 1/5 Motor RPM COND COIL Face Area (Sq ft) Fins per In Rows Circuits VALVECONNECT.(In.ID) Vapor 5/8 3/4 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Vapor ( Ft Tube Length) 5/8 3/4 7/ /8 Liquid ( Ft Tube Length) 3/8 * For tubing sets between 80 ft. and 200 ft. horizontal or 20 ft. vertical differential (250 ft. Equivalent Length), consult the Long---Line Guideline. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 2-STAGE HEAT PUMP APPLICATIONS LONG LINE APPLICATION: An application is considered Long line when the total equivalent tubing length exceeds 80 ft. or when there is more than 20 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. The maximum vertical separation is 200 ft. when outdoor unit Unit Nominal Size (Btuh) 24, Stage Puron HP 36, Stage Puron HP 48, Stage Puron HP 60, Stage Puron HP Acceptable Liquid Line Diameter (in. O.D.) 3/8 Acceptable Vapor Line Diameters (In. O.D.) is above indoor unit, and 80 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long -Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss. Cooling Loss (%) Equivalent Line Length (ft) Standard Application Long Line Application Requires Accessories / / / / / / / / / / Standard Length = 80 ft. or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines 3

4 ACCESSORIES KIT NUMBER KIT NAME KSACY0101AAA CYCLE PROTECTOR S S S S KAAFT0101AAA FREEZE THERMOSTAT* S S S S KHALS0401LLS SOLENOID VALVE X X X X KSASH2201BRL SOUND BLANKET PREMIUM X KSASF0101AAA SUPPORT FEET X X X X KAATD0101TDR TIME DELAY S S S S KSATX0201PUR TXV X KSATX0301PUR TXV X KSATX0401PUR TXV X KSATX0501PUR TXV X KAAWS0101AAA WINTER START S S S S x = Accessory S = Standard * Standard with Infinity Control ACCESSORY THERMOSTATS THERMOSTATS TSTATCCPRH01---B TSTATCCP2S01---B TSTATCCN2S01---B TSTATXXSEN01---B TSTATXXNBP01 TSTATXXPBP01 TSTATXXCNV10 DESCRIPTION Thermidistatt Control Non--- Programmable/Programmable Thermostat with Humidity Control (For use in HybridHeatt (Dual Fuel), AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) Carrier Thermostat, Auto Changeover, 7--- Day Programmable, F/ C, Stage Heat/2 --- Stage Cool in AC Mode, Stage Heat/2 --- Stage Cool in HP mode Carrier Thermostat, Auto Changeover, Non--- Programmable, F/ C, Stage Heat/2 --- Stage Cool in AC Mode, Stage Heat/2 --- Stage Cool in HP mode Outdoor Temperature Sensor Backplate for Non--- Programmable Thermostat Backplate for Programmable Thermostat Thermostat Conversion Kit (4 to 5 Wire) 10 Pack INFINITY* CONTROLS SYSTXCCUID01---A* SYSTXCCUIZ01---A* SYSTXCC4ZC01 SYSTXCCSMS01 SYSTXCCRRS01 SYSTXCCSAM01 SYSTXCCNIM01 SYSTXXXBPU01 Must be installed in HybridHeatt (Dual---Fuel) Infinityt system applications. * These Infinity series units must use ---A revision or later to operate properly. DESCRIPTION Infinity Control Deluxe 7---Day Programmable (Wall---mounted system control.) Infinity Control Deluxe Zoning 7---Day Programmable (Wall---mounted control for a multi---zone system.) Infinity 4---Zone Damper Control Module (Wall---mounted control for a four---zone system.) Infinity Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an individual zone.) Infinity Remote Room Sensor (Monitors temperature in an individual zone.) Infinity Access Module (Hardware for wireless access and control via phone or internet.) Infinity Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators or older two--- speed outdoor models to system.) Decorative Back Plate for Infinity Control (Decorative wall plate.) 4

5 ACCESSORY USAGE GUIDELINE Accessory REQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS (0_F to55_f) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 Ft.) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles) Crankcase Heater Standard Standard Standard Evaporator Freeze Thermostat Standard with Infinity Control (Low Ambient not allowed with non---communicating thermostat) No No Winter Start Control Standard with Infinity Control (Low Ambient not allowed with non---communicating No No thermostat) Accumulator Standard Standard Standard Compressor Start Assist Capacitor and Relay Standard Standard Standard Low Ambient Control Standard with Infinity Control (Low Ambient not allowed with non---communicating No No thermostat) Support Feet Recommended No Recommended Liquid Line Solenoid Valve No Yes No Puron Balance Port Hard Shut---Off TXV Yes{ Yes{ Yes{ Ball Bearing Fan Motor Standard Standard Standard * For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differential (250 ft. Equivalent Length), refer to Long---Line Application Guideline. { Required on all indoor units. Standard on all new Puronr fan coils and furnace coils. Accessory Description and Usage (Listed Alphabetically) 1. Compressor Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Usage Guideline: Suggested when unit is installed closer than 15 ft. to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft. apart. 2. Liquid -Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. 3. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 4. Thermostatic Expansion Valve (TXV) Bi-Flow A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet ARI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant. 5

6 ELECTRICAL DATA UNIT SIZE V --- PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZE{ MIN WIRE SIZE{ MAX LENGTH (FT)} MAX LENGT H(FT)} MAX MIN LRA RLA FLA 60 C 75 C 60 C 75 C MAX FUSE** or CKT BRK AMPS / * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30 C(86 F), consult table of the NEC (ANSI/NFPA 70). The ampacity of non---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conditions, per the NEC (ANSI/NFPA 70) Article If other than uncoated (no---plated), 60 or 75 C (140 or 167 C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time --- Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. A-WEIGHTED SOUND LEVEL (dba) UNIT SIZE STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) RATING low stage high stage low stage high stage low stage high stage low stage high stage A-WEIGHTED SOUND LEVEL (dba) with PREMIUM ACCESSORY SOUND BLANKET UNIT SIZE 36 STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) RATING low stage high stage CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE---SERIES REQUIRED SUBCOOLING (F) OUTDOOR HEATING PISTION # HIGH STAGE HIGH STAGE HIGH STAGE HIGH STAGE 63 6

7 DIMENSIONS 7

8 BALANCE POINT WORKSHEET Low -Stage OUTDOOR TEMPERATURE, ºF BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH kw 60A FE4ANB006 48A FE4ANB006 36A FE4ANB006 24A FE4ANF003 BASED ON INDOOR ENT. AIR AT 70 ºF AND AT RATED 8

9 BALANCE POINT WORKSHEET High -Stage OUTDOOR TEMPERATURE, ºF BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH kw 60A FE4ANB006 48A FE4ANB006 36A FE4ANB006 24A FE4ANF003 BASED ON INDOOR ENT. AIR AT 70 ºF AND AT RATED

10 COMBINATION RATINGS Unit Size --- Series ARI Standard Ratings Cooling Cooling Heating Indoor Model ID CFM High Temp Low Temp SEER EER COP COP HSPF High Low High Low High Low High Low High Low High Low *FE4ANF FE4ANF FV4BNF FV4BNF Furnace Model CAP**2414A** CV(A,X) CAP**2417A** CV(A,X) CAP**2417A** MVB CAP**3014A** CV(A,X) CAP**3017A** CV(A,X) CAP**3017A** MVB CAP**3614A** CV(A,X) CAP**3614A** CV(A,X) CAP**3614A** MVB CAP**3617A** CV(A,X) CAP**3617A** CV(A,X) CAP**3617A** MVB CAP**3617A** MVB CAP**3621A** CV(A,X) CAP**3621A** MVB CAP**3621A** MVB CAP**3621A** MVB CNPH*2417A** CV(A,X) CNPH*2417A** CV(A,X) CNPH*2417A** MVB CNPH*2417A** MVB CNPH*2417A** MVB CNPH*3017A** CV(A,X) CNPH*3017A** CV(A,X) CNPH*3017A** MVB CNPH*3017A** MVB CNPH*3017A** MVB CNPH*3617A** CV(A,X) CNPH*3617A** CV(A,X) CNPH*3617A** MVB CNPH*3617A** MVB CNPH*3617A** MVB CNPV*2414A** CV(A,X) CNPV*2417A** CV(A,X) CNPV*2417A** MVB CNPV*3014A** CV(A,X) CNPV*3017A** CV(A,X) CNPV*3017A** MVB CNPV*3617A** CV(A,X) CNPV*3617A** CV(A,X) CNPV*3617A** MVB CNPV*3617A** MVB CNPV*3621A** CV(A,X) CNPV*3621A** MVB CNPV*3621A** MVB CNPV*3621A** MVB See notes on pg. 15 CSPH*2412A** CV(A,X) CSPH*2412A** CV(A,X) CSPH*2412A** MVB CSPH*2412A** MVB CSPH*2412A** MVB CSPH*3012A** CV(A,X) CSPH*3012A** CV(A,X) CSPH*3012A** MVB CSPH*3012A** MVB CSPH*3012A** MVB

11 COMBINATION RATINGS CONTINUED Unit Size --- Series ARI Standard Ratings Cooling Cooling Heating Indoor Model ID CFM High Temp Low Temp Furnace Model SEER EER COP COP HSPF High Low High Low High Low High Low High Low High Low CSPH*3612A** CV(A,X) CSPH*3612A** CV(A,X) CSPH*3612A** MVB CSPH*3612A** MVB CSPH*3612A** MVB *FE4ANB FE4ANF FE4ANF FE4ANF FE5ANB FV4BNB FV4BNF FV4BNF FV4BNF CAP**3614A** CV(A,X) CAP**3614A** CAP**3617A** CV(A,X) CAP**3617A** MVB CAP**3617A** CAP**3621A** CV(A,X) CAP**3621A** MVB CAP**3621A** MVB CAP**3621A** MVB CAP**3621A** CAP**4221A** CV(A,X) CAP**4221A** MVB CAP**4221A** MVB CAP**4221A** MVB CAP**4221A** CAP**4224A** CV(A,X) CAP**4224A** CV(A,X) CAP**4224A** MVB CAP**4224A** MVB CAP**4224A** CAP**4817A** CV(A,X) CAP**4817A** CV(A,X) CAP**4817A** CV(A,X) CAP**4817A** MVB CAP**4817A** MVB CAP**4817A** MVB CAP**4817A** MVB CAP**4817A** CAP**4821A** CV(A,X) CAP**4821A** CV(A,X) CAP**4821A** CV(A,X) CAP**4821A** CV(A,X) CAP**4821A** MVB CAP**4821A** MVB CAP**4821A** MVB CAP**4821A** MVB CAP**4821A** MVB CAP**4821A** MVB CAP**4821A** CAP**4824A** CV(A,X) CAP**4824A** CV(A,X) CAP**4824A** CV(A,X) CAP**4824A** MVB CAP**4824A** MVB CAP**4824A** MVB CAP**4824A** MVB CAP**4824A** MVB CAP**4824A** CNPF*3618A** See notes on pg

12 COMBINATION RATINGS CONTINUED Unit Size --- Series Indoor Model ARI Standard Ratings Cooling Cooling Heating ID CFM High Temp Low Temp SEER EER COP COP High Low High Low High Low High Low High Low High Low HSPF Furnace Model CNPF*4818A** CNPH*3617A** CV(A,X) CNPH*3617A** CV(A,X) CNPH*3617A** CV(A,X) CNPH*3617A** CV(A,X) CNPH*3617A** CV(A,X) CNPH*3617A** MVB CNPH*3617A** MVB CNPH*3617A** MVB CNPH*3617A** MVB CNPH*3617A** MVB CNPH*3617A** MVB CNPH*3617A** CNPH*4221A** CV(A,X) CNPH*4221A** CV(A,X) CNPH*4221A** CV(A,X) CNPH*4221A** CV(A,X) CNPH*4221A** CV(A,X) CNPH*4221A** MVB CNPH*4221A** MVB CNPH*4221A** MVB CNPH*4221A** MVB CNPH*4221A** MVB CNPH*4221A** MVB CNPH*4221A** CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** CNPV*3617A** CV(A,X) CNPV*3617A** MVB CNPV*3617A** CNPV*3621A** CV(A,X) CNPV*3621A** MVB CNPV*3621A** MVB CNPV*3621A** MVB CNPV*3621A** CNPV*4221A** CV(A,X) CNPV*4221A** MVB CNPV*4221A** MVB CNPV*4221A** MVB CNPV*4221A** CNPV*4821A** CV(A,X) CNPV*4821A** CV(A,X) CNPV*4821A** CV(A,X) CNPV*4821A** CV(A,X) CNPV*4821A** MVB CNPV*4821A** MVB CNPV*4821A** MVB CNPV*4821A** MVB CNPV*4821A** MVB CNPV*4821A** MVB CNPV*4821A** CNPV*4824A** CV(A,X) CNPV*4824A** CV(A,X) CNPV*4824A** CV(A,X) CNPV*4824A** MVB CNPV*4824A** MVB CNPV*4824A** MVB See notes on pg

13 COMBINATION RATINGS CONTINUED Unit Size --- Series ARI Standard Ratings Cooling Cooling Heating Indoor Model ID CFM High Temp Low Temp Furnace Model SEER EER COP COP HSPF High Low High Low High Low High Low High Low High Low CNPV*4824A** MVB CNPV*4824A** MVB CNPV*4824A** CSPH*3612A** CV(A,X) CSPH*3612A** CV(A,X) CSPH*3612A** CV(A,X) CSPH*3612A** CV(A,X) CSPH*3612A** CV(A,X) CSPH*3612A** MVB CSPH*3612A** MVB CSPH*3612A** MVB CSPH*3612A** MVB CSPH*3612A** MVB CSPH*3612A** MVB CSPH*3612A** CSPH*4212A** CV(A,X) CSPH*4212A** CV(A,X) CSPH*4212A** CV(A,X) CSPH*4212A** CV(A,X) CSPH*4212A** CV(A,X) CSPH*4212A** MVB CSPH*4212A** MVB CSPH*4212A** MVB CSPH*4212A** MVB CSPH*4212A** MVB CSPH*4212A** MVB CSPH*4212A** CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** *FE4ANB FE4ANF FV4BNB FV4BNF CAP**4817A** CV(A,X) CAP**4817A** CAP**4821A** CV(A,X) CAP**4821A** MVB CAP**4821A** MVB CAP**4821A** CAP**4824A** CV(A,X) CAP**4824A** CV(A,X) CAP**4824A** MVB CAP**4824A** CAP**6021A** CV(A,X) CAP**6021A** MVB CAP**6021A** MVB CAP**6021A** CAP**6024A** CV(A,X) CAP**6024A** CV(A,X) CAP**6024A** MVB CAP**6024A** CNPF*4818A** CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*4821A** CV(A,X) See notes on pg

14 COMBINATION RATINGS CONTINUED Unit Size --- Series ARI Standard Ratings Cooling Cooling Heating Indoor Model ID CFM High Temp Low Temp Furnace Model SEER EER COP COP HSPF High Low High Low High Low High Low High Low High Low CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** MVB CNPH*4821A** CNPH*6024A** CV(A,X) CNPH*6024A** CV(A,X) CNPH*6024A** CV(A,X) CNPH*6024A** CV(A,X) CNPH*6024A** MVB CNPH*6024A** MVB CNPH*6024A** MVB CNPH*6024A** CNPV*4821A** CV(A,X) CNPV*4821A** MVB CNPV*4821A** MVB CNPV*4821A** CNPV*4824A** CV(A,X) CNPV*4824A** CV(A,X) CNPV*4824A** MVB CNPV*4824A** CNPV*6024A** CV(A,X) CNPV*6024A** CV(A,X) CNPV*6024A** MVB CNPV*6024A** CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** MVB CSPH*4812A** CSPH*6012A** CV(A,X) CSPH*6012A** CV(A,X) CSPH*6012A** CV(A,X) CSPH*6012A** CV(A,X) CSPH*6012A** MVB CSPH*6012A** MVB CSPH*6012A** MVB CSPH*6012A** *FE4ANB FV4BNB CAP**6021A** CV(A,X) CAP**6021A** MVB CAP**6021A** MVB CAP**6021A** CAP**6024A** CV(A,X) CAP**6024A** CV(A,X) CAP**6024A** MVB CAP**6024A** CNPH*6024A** CV(A,X) CNPH*6024A** CV(A,X) CNPH*6024A** CV(A,X) CNPH*6024A** MVB CNPH*6024A** MVB CNPH*6024A** MVB CNPH*6024A** CNPV*6024A** CV(A,X) CNPV*6024A** CV(A,X) CNPV*6024A** MVB CNPV*6024A** See notes on pg

15 COMBINATION RATINGS CONTINUED Unit Size --- Series ARI Standard Ratings Cooling Cooling Heating Indoor Model ID CFM High Temp Low Temp Furnace Model SEER EER COP COP HSPF High Low High Low High Low High Low High Low High Low CSPH*6012A** CV(A,X) CSPH*6012A** CV(A,X) CSPH*6012A** CV(A,X) CSPH*6012A** MVB CSPH*6012A** MVB CSPH*6012A** MVB CSPH*6012A** * Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit. High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43 F (6_C) wb air entering outdoor unit. Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (±9_C) db 15 F (±10_C) wb air entering outdoor unit. SEER Seasonal Energy Efficiency Ratio COP Coefficient of Performance TDR Time---Delay Relay HSPF Heating Seasonal Performance Factor EER Energy Efficiency Ratio 15

16 DETAILED COOLING CAPACITIES EVAPORATOR AIR CFM EWB EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES deg F Sens Sens Sens Sens Sens Sens 24A30 Outdoor Section With FE4ANF003 Indoor Section -High Stage CONDENSER ENTERING AIR TEMPERATURES deg F Sens Sens Sens Sens Sens Sens 24A30 Outdoor Section With FE4ANF003 Indoor Section - Low Stage See notes on pg

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features

More information

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide

More information

Product Data. Reliability

Product Data. Reliability Infinityt19 2 --- Stage Heat Pump with Puronr Refrigerant 3to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. S SEER/ EER/ HSPF S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S SEER/ EER/ HSPF S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 25VNA Infinityr Variable Speed Heat Pump with Greenspeedt Intelligence 2to5NominalTons Product Data Carrier s 25VNA with Greenspeedt Intelligence is a breakthrough product providing up to 13 HSPF heating

More information

Product Data. 24ANB1 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

Product Data. 24ANB1 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons Infinityt 21 2---Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound 24VNA9 Infinityr 19VS Variable Air Conditioner with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably small

More information

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and

More information

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and provides up

More information

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES: 16 SEER 2---Stage Split---tem Heat Pump With R---410A Refrigerant 2 To 5 Tons (024---060) Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 288BNV EVOLUTION R V VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT 2, 3, 4 AND 5-TON Product Data The Evolutionr V heat pump offers high -efficiency variable speed performance in a remarkably small

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER HVH8 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUP WITH OBSERVER COUNICATING CONTROL SYSTE 2 THRU 5 TONS SPLIT SYSTE 208 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Variable

More information

Product Data. SYNERGY YDA (60 Hz) Two-Speed Electric Heat Pump. Sizes 036, 048, and 060 FEATURES/BENEFITS

Product Data. SYNERGY YDA (60 Hz) Two-Speed Electric Heat Pump. Sizes 036, 048, and 060 FEATURES/BENEFITS Product Data SYNERGY 2000 38YDA (60 Hz) Two-Speed Electric Heat Pump Sizes 036, 048, and 060 Model 38YDA Heat Pumps incorporate innovative 2-speed compressor technology to provide quiet, efficient summer

More information

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS Product Data SYNERGY 2000 38 TDA (60 Hz) Two-Speed Electric Air Conditioner Sizes 036, 048, and 060 Model 38TDA Air Conditioners incorporate innovative 2-speed compressor technology to provide quiet, efficient

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210565 December 2010 Supersedes November 2010 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL SYSTXCCUIZ01-- B Infinityt Zone Control Product Data A07258 NOTE: Infinity Zone Control compatible with Infinity rated indoor equipment only. INFINITY t ZONE CONTROL Carrier specializes in creating a customized

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210475 October 2009 Supersedes March 2009 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC014-EN Split System Cooling Product & Performance Data 2TTA0030-072A 2½ 6 Tons PUB. NO. 22-1740-01-0702 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA0 split systems

More information

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A, SINGLE Technical Data Book 4Way Cassette S for (Inv, R410A, 1 Ver.1.0 Release Single 4Way Cassette S for USA (Inv, R410A, 60Hz, HP) TDB 15.02.05 - Ver.1. 5.0.09 Ver.1..0.0 Ver.1..0. Index 1 Nomenclature

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC009-EN Split System Cooling Product & Performance Data 2TTA2030-060A 2½ 5 Tons PUB. NO. 22-1735-01-0302 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA2 split systems

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL8B024 THRU 060

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL8B024 THRU 060 TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: HL8B024 THRU 060 Due to continuous product improvement, specifications are subject to change

More information

CONDENSING UNITS UASL- JEC

CONDENSING UNITS UASL- JEC FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

TECHNICAL GUIDE. Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL6B 024 THRU 060

TECHNICAL GUIDE. Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL6B 024 THRU 060 TECHNICAL GUIDE Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: HL6B 024 THRU 060 Due to continuous product improvement, specifications are subject

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial

More information

R410A D2D_AU019E/

R410A D2D_AU019E/ R41A 2. : AUU18RCLX AUU24RCLX D2D_AU19E/ 27.6.11 2-1. FEATURE MODELS : AUU18RCLX / AOU18RLX AUU24RCLX / AOU24RLX FEATURES Easy maintenance The control box is easily accessible for maintenance work Wide

More information

Ruud Achiever Series Heat Pump

Ruud Achiever Series Heat Pump Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control Product Data A11577 NOTE: Infinityr Touch Control compatible with Infinityr rated indoor equipment only. US Patents: Carrierr

More information

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System 16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control System Efficiencies up to 16.5 SEER/13.0 EER Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities

More information

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions... Airflow Data...6 Heat Kit Data... Wiring

More information

Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: YZF 024 THRU 060

Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: YZF 024 THRU 060 DESCRIPTION The 16 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A CPH Series 7½- to 12½-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Heat Pump with R-410A Standard

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot

More information

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

CTXA-AS/AT/AW, FTXA-AS/AT/AW

CTXA-AS/AT/AW, FTXA-AS/AT/AW Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

H-MSTB March Replaces H-MSTB, Nov M Series. AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor Models. Technical Guide MOH MOZ MOS

H-MSTB March Replaces H-MSTB, Nov M Series. AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor Models. Technical Guide MOH MOZ MOS H-MSTB March 2014 Replaces H-MSTB, Nov 2012 M Series AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor s Technical Guide MOH MOZ MOS Table of Contents 1/2 To 6 HP Indoor & Outdoor Condensing Units

More information

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.

More information

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series 16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control 2 System Efficiencies up to 18 /14 Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities

More information

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book Wind-Free 4Way Cassette for North America (R4A, HP) Model : AM***NN4DCH/** History Version Modification Date Remark Ver.1. Released VRF Wind-Free 4Way Cassette for north America

More information

Daikin McQuay. Enfinity Water Source Heat Pump Ceiling Mounted. WCCH, WCCW 072, 096, 120 Design 1

Daikin McQuay. Enfinity Water Source Heat Pump Ceiling Mounted. WCCH, WCCW 072, 096, 120 Design 1 Replacement Parts List No. 700017500 Revision C 10/2015 Daikin McQuay Enfinity Water Source Heat Pump Ceiling Mounted WCCH, WCCW 072, 096, 120 Design 1 To find your Daikin Applied parts distributor, call

More information

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA181, WA241 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintage A. TYA, TAA No Vintage. Last Manufactured: 1993

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintage A. TYA, TAA No Vintage. Last Manufactured: 1993 Replacement Parts List No. 055203200 Revision G 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-15 Vintage A TYA, TAA 007-015 No Vintage Last Manufactured: 1993 To find your Daikin Applied

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan DCH Series Submittal Data Form 7½ - 12½ Ton Packaged Heat Pump Up to 11.5 EER & 3.4 COP Cooling Capacity: 90,000 140,000 BTU/h Heating Capacity: 90,000 142,000 BTU/h Job Name Purchaser Order No. Engineer

More information

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name:

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name: Project Information Project Name: Ulta 1307 Seneca SC Product Submittal Project Number: 3000662696 Project Location: HARTWELL VILLAGE SENECA, SC 29678, US Project Altitude: 956 Customer Information Company

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-C Indoor Unit FTX-C TALE OF CONTENTS FTX-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

J&M Fluidics, Inc. Company Product Overview

J&M Fluidics, Inc. Company Product Overview It s All about Building a Better Product for Our Clients! J&M Fluidics, Inc. Company Product Overview J&M Fluidics, Manufacturer of Air & Water-Cooled Process Chillers. Located in Telford, Pennsylvania

More information

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

VRF. Technical Data Book. DVM S Eco 8, 9 HP

VRF. Technical Data Book. DVM S Eco 8, 9 HP VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature

More information

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF DTH Series Submittal Data Form 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF Cooling Capacity: 35,000 60,000 BTU/h Heating Capacity: 32,800 55,500 BTU/h Purchaser Order No. Engineer Unit No. Model

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)

More information

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: AL6B024 THRU 060

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: AL6B024 THRU 060 TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: AL6B024 THRU 060 Due to continuous product improvement, specifications are subject to change

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change

More information

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough

More information

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL Product Data NOTE: Evolution Zone Control compatible with Evolution rated indoor equipment only. EVOLUTION t ZONE CONTROL Bryant specializes in creating a customized

More information

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013 Replacement Parts List No. 700017400 Revision G 12/2013 Daikin McQuay Incremental Comfort System PKEI, PKES, PKHS 007, 009, 012, 014 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH*** VRF Technical Data Book Slim duct for America (R41A, 6Hz, HP) Model : AM***FNLDCH*** History Version Modification Date Remark Ver.1. Release Slim duct for America (R41A, 6Hz, HP) 1.11.4 - Ver.1.1 1.12.28

More information

McQuay. Water Source Heat Pump Large Vertical. VWG, VWH, VWW Vintage D. Last Manufactured: 1997

McQuay. Water Source Heat Pump Large Vertical. VWG, VWH, VWW Vintage D. Last Manufactured: 1997 Replacement Parts List No. 057103800 Revision D 02/2017 McQuay Water Source Heat Pump Large Vertical VWG, VWH, VWW 07-27 Vintage D Last Manufactured: 1997 To find your Daikin Applied parts distributor,

More information

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class

More information

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA 99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and

More information

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

Brasch Washdown Unit Heaters

Brasch Washdown Unit Heaters Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt

More information

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51 CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG8-AU6-B ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-746 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

SECO THERMOSTAT Gas/electric 24 volt, heating, cooling mercury switch, ivory color

SECO THERMOSTAT Gas/electric 24 volt, heating, cooling mercury switch, ivory color CAUDILL SUPPLY INC. Page 1 SECO THERMOSTAT Gas/electric 24 volt, heating, cooling mercury switch, ivory color AC 3050 SECO HEAT PUMP THERMOSTAT 2 stage heat, 1 stage cool, 24 volt, manual change over,

More information

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control INDUSTRY LEADING FEATURES / BENEFITS

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control INDUSTRY LEADING FEATURES / BENEFITS SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated indoor equipment only. US Patents: Carrierr

More information

WO P-NF-L-M-407c Spec Submittal

WO P-NF-L-M-407c Spec Submittal WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational

More information

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C* System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

Trailblazer AGZ-E air-cooled scroll chillers

Trailblazer AGZ-E air-cooled scroll chillers Trailblazer AGZ-E air-cooled scroll chillers 30 to 240 tons with Variable Speed Condenser Fan Technology The right features, the right value, right now Intelligent Equipment AGZ-E 30 to 161 RapidRestore

More information

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors. Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from

More information