2 Traffic Monitoring and Engineering for UCS Steve McQuerry, CCIE# 6108 Technical Marketing Engineer

3 Agenda UCS Networking Overview Network Statistics in UCSM Understanding Collection Policies Hotspot Detection Engineering to Avoid Hotspots 3

4 UCS Networking Overview

5 System Components: High-level Overview FABRIC INTERCONNECT CHASSIS IO MODULE (FEX) 61XX 62XXUP 2104XP 2204XP 2208XP 2232PP Cisco (VIC1280, VIC1225) 3 rd party INTERFACE CARDS 5

6 UCS Networking Overview Fabric Interconnects (10GE ports) Chassis Up to 8 half width blades or 4 full width blades Fabric Extender (FEX or I/O Module) Host to uplink traffic engineering Up to 160Gb Flexible bandwidth allocation Adapters Virtualized adapter for single OS and hypervisor systems Dual connected Blade or Stand Alone Server 6

7 UCS Networking Overview 1 st Generation Hardware vpc SAN A SAN B Port-Channel Fabric A FEX A Port-Channel Fabric B FEX B Mezz Mezz Mezz n i c n i c h a h a b b n i c n i c h a h a b b n i c n i c h a h a b b 7

8 UCS 2104 (1st Gen FEX) Server to Fabric Pinning slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 1 link NIF Fabric Interconnect Server slots pinned to uplink Uplink: slots 1,2,3,4,5,6,7,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 2 links NIF Fabric Interconnect Uplink 1: slots 1,3,5,7 Uplink 2: slots 2,4,6,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 4 links NIF Fabric Interconnect Uplink 1: slots 1,5 Uplink 2: slots 2,6 Uplink 3: slots 3,7 Uplink 4: slots 4,8 8

9 UCS Networking Overview 1 st Generation Hardware Fabric A IOM A Fabric B IOM B Mezz n i c n i c h a h a b b 9

10 UCS Networking Overview 2 nd Generation Hardware vpc SAN A SAN B Port-Channel Fabric A IOM A Port-Channel Fabric B IOM B Mezz Mezz Mezz n i c n i c h a h a b b n i c n i c h a h a b b n i c n i c h a h a b b 10

11 UCS 2204 (2 nd Gen FEX) Sever to Fabric Pinning slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 1 link NIF Fabric Interconnect Server slots pinned to uplink Uplink: slots 1,2,3,4,5,6,7,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 2 links NIF Fabric Interconnect Uplink 1: slots 1,3,5,7 Uplink 2: slots 2,4,6,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 4 links NIF Fabric Interconnect Uplink 1: slots 1,5 Uplink 2: slots 2,6 Uplink 3: slots 3,7 Uplink 4: slots 4,8 11

12 UCS 2204 (2 nd Gen FEX) Sever to Fabric Pinning Server slots channeled across all uplinks slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 4 links NIF Fabric Interconnect Uplink 1: slots 1-8 Uplink 2: slots 1-8 Uplink 3: slots 1-8 Uplink 4: slots

13 UCS 2208 (2 nd Gen FEX) Server to Fabric Pinning slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 1 link NIF Fabric Interconnect Server slots pinned to uplink Uplink: slots 1,2,3,4,5,6,7,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 2 links NIF Fabric Interconnect Uplink 1: slots 1,3,5,7 Uplink 2: slots 2,4,6,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 4 links NIF Fabric Interconnect Uplink 1: slots 1,5 Uplink 2: slots 2,6 Uplink 3: slots 3,7 Uplink 4: slots 4,8 13

14 UCS 2208 (2 nd Gen FEX) Server to Fabric Pinning Server slots pinned to uplink slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X F E X 8 links NIF Fabric Interconnect Uplink 1: slot 1 Uplink 2: slot 2 Uplink 3: slot 3 Uplink 4: slot 4 Uplink 5: slot 5 Uplink 6: slot 6 Uplink 7: slot 7 Uplink 8: slot 8 Server slots channeled across all uplinks 8 links Uplink 1: slots 1-8 NIF Fabric Interconnect Uplink 2: slots 1-8 Uplink 3: slots 1-8 Uplink 4: slots 1-8 Uplink 5: slots 1-8 Uplink 6: slots 1-8 Uplink 7: slots 1-8 Uplink 8: slots

15 UCS Networking Overview 2 nd Generation Fabric Interconnect Fabric A IOM A Fabric B IOM B Mezz n i c n i c h a h a b b 15

16 Network Statistics in UCSM

17 UCSM Core IBM Tivoli HPNNM Events {SNMP Traps} HPOM Polls {SNMP GET} Misc. SNMP Events {xml} HTTP {xml} CIM-XML SNMP Syslog Smash XML API UCS CLI U C S M CIM Object Translation AG blade DME AG FI AG chassis AG n DB Polling/notification 17

18 UCSM Statistics Root topsys sys equipmentchassis sys/chassis-1 equipmentchassisstats equipmentchassisstatshist sys/chassis-1/stats/1 sys/chassis-1/stats Statistics are instances of statscurr Statistics are contained by monitored object 5 most recent stats history records are contained by the current stats instance. Stats history are subclasses of the stats. Statistics dn is often deducible.... equipmentchassisstatshist sys/chassis-1/stats/5 18

19 Stats Collection Policy A Systemwide Set of Stats Collection Policies (One per Application Domain) Allow Configuration of Collection and Reporting Intervals. Domains: adapter, chassis, host, port, server When a Collection Interval Is Changed, the reportinginterval Is Restarted collectioninterval: frequency that endpoints will send stats updates to DME reportinginterval: frequency that DME will report stats updates to external collectors and update stats history 19

20 Network Statistics in UCSM Network statistics are collected by UCSM from the NX-OS software in the Fabric Interconnects. These are counters that are available for networking components Because of NIV technology the Fabric has visibility to the Cloud (LAN/SAN uplinks), the IOM and the server NIC. 20

21 Network Statistics in UCSM Access Statistics through: LAN or SAN tab (port-group) Devices tab ( server ports, network uplink, storage ports, and mezz ports,) Server Tab (vnic) 21

22 Network Statistics in UCSM FI to LAN Network Uplink (Cloud) vpc SAN A Port-Channel Port-Channel Fabric A Fabric B 22

23 Network Statistics in UCSM Port Channel is the Aggregate of all interfaces in the channel Statistic for the channel are the sum of the statistics of the members Individual member statistics are also visible in the system Network usage is measured against TX Total bytes and RX Total bytes 23

24 Network Statistics in UCSM FI to Uplink Port Channel Statistics 24

25 Network Statistics in UCSM FI to Uplink Individual Port Statistics 25

26 Network Statistics in UCSM FI to SAN Port Statistics SAN A SAN B Fabric A Fabric B 26

27 Network Statistics in UCSM FI to SAN Uplink (Cloud) Port Statistics A FC Port Channel is the Aggregate of all interfaces in the channel Statistic for the channel are the sum of the statistics of the members Individual member statistics are also visible in the system FC usage is measured against Bytes RX and Bytes TX 27

28 Network Statistics in UCSM FI to SAN Port Statistics 28

29 Network Statistics in UCSM FI to IOM (Internal LAN) Fabric A Fabric B IOM A IOM B 29

30 Network Statistics in UCSM FI to IOM (Internal LAN) 30

31 UCS Networking Overview Server to IOM n i c n i Mezz c h a h a b b 31

32 Network Statistics in UCSM Server to IOM vnic Port Statistics 32

33 Using SNMP tools to Monitor Traffic The network statistics in UCSM are pulled from the NX-OS statistics for the networking components. It is possible to monitor the traffic for the networking components using an external SNMP collection tool such as MRTG. The advantage is long term analysis, however most tools have no alerting capabilities. 33

34 Understanding Collection Policies

35 Understanding Collection Policies A collection Policy consist of a collection interval and a reporting interval The collection policy is set under the admin tab in Stats Management -> Collection Policies -> Collection Policy name A unique policy can be set for, Adapters, Chassis, FEX, Port, Server, and Host* Not all policies involve network components *Host is an unused policy in UCSM at present 35

36 Understanding Collection Policies 36

37 Understanding Collection Policies Collection Interval The collection interval is how often the system will query a device for statistics. The default collection interval is 60 seconds The more frequent the interval the more granular the data. We will use 30 seconds. The timing of the collection interval is important because it will be used in BW calculations for hotspot detection 37

38 Understanding Collection Policies Reporting Interval The reporting interval is internal to UCSM and determines how often UCSM will store data from the collection interval. This data is stored in tables and the last 5 reporting intervals are available for inspection in the system Reporting interval data is used to calculate minimum, maximum and average values shown in the statics view. 38

39 Understanding Collection Policies Select the Policy you want to change. Make selections and press the save changes button 39

40 Hotspot Detection

41 Hotspot Areas There are three potential hotspot locations for UCS network connectivity. 1.) Send and Receive between Fabric Interconnect and LAN/SAN Fabric Interconnects to LAN/SAN FEX to FI FEX to Host SAN A Port-Channel Fabric A FEX A SAN B Port-Channel Fabric B FEX B 2.) Send and Receive between FEX and Fabric Interconnect 3.) Send and Receive between Host and FEX n i Mezz cn i ch ah a b b n i Mezz cn i ch ah a b b n i Mezz cn i ch ah a b b 41

42 Hotspot Detection Threshold Policies To identify hot spots we will use Threshold policies in conjunction with collection policies to alert as we pass thresholds. A threshold is calculated by measuring a statistic against a policy. The policy measures change against a user defined normal value and turns on the alert between a users set high/low threshold and turns off the alert below the user set low threshold. High - Up High - Up High - Up Low - Up Low - Up Low - Up Normal Normal Normal 42

43 Hotspot Detection Calculating BW Threshold Limits for an Element The statistic we use to calculate bandwidth is the delta in bytes. This should be measured for both TX and RX This delta is calculated in bytes changed over a period of time defined by the collection interval, for example 30 seconds 43

44 if standardizing on one size was a good thing, standardizing on several sizes would be even better. Radia Perlman Interconnections: Bridges and Routers 44

45 Kilo, Mega, etc IEEE Networking Standards for Prefix Values What is a Kilobit? Once upon a time Computer professionals noticed that 2 10 was very nearly equal to 1000 and started using the SI prefix kilo to mean The rest of the world uses the term Kilo in the SI format to mean The result is that no one seems to know what kilo and mega mean. The IEEE standards board decided that the IEEE standards will use the conventional, internationally adopted, definitions of the SI prefixes. Therefore Mega will mean 1,000,000 and Kilo will mean 1,000.* In Telecom and by extension networking Kilo means 1000 and NOT 1024 The SNMP reported speed for a 10Gig link (on any platform) will be reported by SNMP is 1,250,000,000 Bytes (MaxBytes[ _ ]: ) *Sources: NIST and IEEE 45

46 Hotspot Detection Calculating BW Threshold Limits for an Element For Ethernet the BW of a single link is 10Gbps First we determine our desired threshold for example 8Gbps We need to calculate the expected change in bytes over the collection interval. To calculate divide the desired BW by 8 bits per byte and then multiply by the collection interval by the time to get the expected delta in bytes for our collection period. Example 8 Gbps over 30 seconds = 30,000,000,000 bytes 8Gbps / 8bits per byte = 1,000,000,000 bytes per second 1,000,000,000 bytes per second * 30 seconds = 30,000,000,000 bytes 46

47 Hotspot Detection Threshold Calculations Speed in Gbps Percentage of BW Conversion to Bytes Delta expected over 30 second collection interval % 1,250,000,000 37,500,000, % 1,125,000,000 33,750,000, % 1,062,500,000 31,875,000, % 1,000,000,000 30,000,000, % 937,500,000 28,125,000, % 875,000,000 26,250,000, % 812,500,000 24,375,000, % 750,000,000 22,500,000, % 625,000,000 18,750,000, % 500,000,000 15,000,000, % 375,000,000 11,250,000,000 47

48 Hotspot Detection Threshold Alerts 48

49 Hotspot Detection Threshold Policies Placement Threshold policies can be configured for the following: Internal LAN IOM to FI LAN Cloud FI to Upstream Ethernet switches SAN Cloud FI to Upstream SAN switches Server Between the server NIC and the IOM 49

50 Hotspot Detection Threshold Policies Internal LAN Navigate to admin->stats management and expand the fabric. Select thr-policy-default and create a threshold class Choose Ether Tx Stats from the stat class and click next. 50

51 Hotspot Detection Threshold Policies Internal LAN 51

52 Hotspot Detection Threshold Policies Internal LAN 52

53 Hotspot Detection Threshold Policies Click the add button and select Ether Tx Stats Total Bytes Delta as the property type enter 0.0 as the normal value Select the Alarm triggers you want to get and enter your values and click OK Click finish to be returned to the policy. Click the classes tab to see your policy. 53

54 Hotspot Detection Threshold Policies Internal LAN 54

55 Hotspot Detection Threshold Policies You will need to add another class for RX traffic. Click the + bottom to the right and repeat the steps from the previous policy choosing Eter Rx Stats as the stats class this time Click save changes once you have completed the steps 55

56 Hotspot Detection Threshold Policies 56

57 Hotspot Detection Threshold Policies For Uplinks you can repeat this process for the LAN cloud. For SAN use a single Stats class fcstats and create a definition for rx and tx stas under the same stats class 57

58 Hotspot Detection Threshold Policies 58

59 Hotspot Detection Threshold Policies For the vnic port you will need to create a threshold policy to be used with a service profile. Go the the appropriate organization level and select create threshold policy 59

60 Hotspot Detection Threshold Policies 60

61 Hotspot Detection Threshold Policies Give the policy an applicable name and description and press next Choose the vnic stats class and create a single threshold with the rx bytes delta and the tx bytes delta. 61

62 Hotspot Detection Threshold Policies 62

63 Hotspot Detection Threshold Policies Apply the threshold policy to the Service profile of the servers you want to monitor 63

64 Hotspot Detection Threshold Policies When a server reaches a threshold you will receive an alert on UCSM. This will exist while threshold is exceeded once it drops below the definition the alert will disappear Alerts show as system faults as defined by the threshold policy UCSM will send a TRAP when an alert is generated. The TRAP will be sent regardless of what level of alert has been set. 64

65 Hotspot Detection Threshold Policies 65

66 Hotspot Detection When a threshold policy has been crossed UCSM will send out an SNMP Trap alert This assumes that UCSM has been configured for SNMP operation and the Trap Receiver has been defined This feature was added in UCSM version 2.x.x 66

67 Hotspot Detection Long Term Monitoring vs. Point in Time UCSM has a limited amount of space to store statistics and can only provide the last 5 instances of collection intervals. It provides a good tool for monitoring thresholds, but does not provide a long term monitoring solution. Tools like MRTG are great for Long Term analysis of BW usage, but may not provide the required alerting and usually require a great deal of customization to be usable UCS Central version (TBD) will provide tools for both alerting as well as long term analysis of traffic within systems it manages. 67

68 Automating Threshold Policies GoUCS and CDN Creating threshold policies for the systems require time and effort. Isn t there some way to push standard configurations to the system? GoUCS is an automation tool available from the Cisco Developer Network (CDN) that allows users to build XML configuration scripts that can be sent to UCS. PowerTool can also be used to automate this process 69

69 Engineering to Avoid Hotspots

70 Traffic Engineering vnics can be pinned to a specific FI when created (with configurable failover to other switch) Depending on requirements, vnics could be pinned to one interconnect or distributed evenly vnic-1 vnic-2 FEX-1 2 Fabric Extenders in chassis, each with 1 link to the FI. vnic-3 VIC with 3 vnics Blade-2, VIC-1 vnic-1 vnic-2 Blade-1, VIC-1 FI-1 vnics in System Class C pinned to one interconnect 2 FI, both with 1 connection to each FEX vnic-3 FEX-2 Class-A Class-B Class-C FI-2 71

71 Controlling Pinning in Profile From the each server a fabric interconnect can be chosen to balance the traffic 72

72 Traffic Engineering vnics can be pinned to a specific FI when created (with configurable failover to other switch) Depending on requirements, vnics could be pinned to one interconnect or distributed evenly vnic-1 vnic-2 FEX-1 vnic-3 Blade-1, VIC-1 FI-1 vnics in System Class C distributed across interconnects Blade-2, VIC-1 vnic-1 vnic-2 vnic-3 FEX-2 Class-A Class-B Class-C FI-2 73

73 QoS Architecture SAN G G G A G Compute Chassis Fabric R Extender x8 M Adapter B LAN S Fabric Switch G I x8 C MGMT I x8 R x8 X X X X X X x86 Computer x86 Computer Compute Blade (Half slot) C S G Fabric Switch G P Adapter B G A G G P Adapter Compute Blade (Full slot) SAN Fabric Extender No packet drops within the array Largest buffers are on switch and host memory, so congestion pushed to edges Priority Flow Control (PFC) used to ensure packet drops are at vnic or Switch All traffic in a CA system belongs to 1 of 6 System Classes Four are user configurable while the other two are for FCoE and standard Ethernet QoS parameters can be configured at a per system class level, or a per vnic level. 74

74 System Buffering/Queuing 75

75 User Configuration Users configure QoS parameters at two levels Globally for each System Class COS value for packets in this class Drop/No-drop behavior Strict Priority Example Class Name FC Bronze COSValue 3 0 Drop/No-Drop No-Drop Drop Strict Priority No No Bandwidth/Weight 20% 30% Bandwidth/Weight 76

76 User Configuration Users configure QoS parameters at two levels Example: Logical Server A vnic1 vnic2 vnic3 Class FC FC Bronze Rate Burst For each vnic (Egress properties) System Class for traffic from this vnic Rate limit (Mbps) Burst Size (Kbytes) 77

77 User Configuration Example Global System Class Definitions Class Name FC Gold Ethernet BE COS Value Drop/No-Drop No-Drop Drop Drop Strict Priority No No No Bandwidth/Weight 1 (20%) 3 (60%) 1 (20%) FC Traffic High Priority Ethernet Best Effort Ethernet Logical Server A vnic1 vnic2 vnic3 Class FC FC Eth. BE Rate Burst Logical Server B vnic1 vnic2 Class Gold Eth. BE Rate Burst

78 QoS Tools Transmit Queues One Two Three Four Five Six Seven Eight Priority Flow Control STOP Ethernet Link Receive Buffers One Two Three Four Five PAUSE Six Seven Eight Enables lossless Fabrics for each class of service PAUSE sent per virtual lane when buffers limit exceeded Eight Virtual Lanes 3G/s COS based Bandwidth Management Offered Traffic 3G/s 2G/s 3G/s 3G/s 3G/s 3G/s 4G/s 6G/s 10 GE Link Realized Traffic Utilization 3G/s 3G/s 3G/s HPC Traffic 3G/s Storage Traffic 3G/s LAN Traffic 4G/s t1 t2 t3 t1 t2 t3 Enables Intelligent sharing of bandwidth between traffic classes control of bandwidth 802.1Qaz Enhanced Transmission 2G/s 3G/s 5G/s Among the tools used are aggregate shapers at the vnics (VIC Adapter), ETS, Policers at the switch for each vnic. 79

79 QoS Configuration in UCSM Enable QoS Classes in UCSM 80

80 QoS Configuration in UCSM Create a QoS Policy 81

81 Applying QoS to a Policy Apply Policy to Adapter 82

82 Summary UCSM is designed for optimized traffic flow Stats Management and Threshold policies allow you to monitor traffic levels QoS and Traffic engineering tools allow you to manage potential bottlenecks in UCS 83

83 Complete Your Online Session Evaluation Give us your feedback and you could win fabulous prizes. Winners announced daily. Receive 20 Cisco Daily Challenge points for each session evaluation you complete. Complete your session evaluation online now through either the mobile app or internet kiosk stations. Maximize your Cisco Live experience with your free Cisco Live 365 account. Download session PDFs, view sessions on-demand and participate in live activities throughout the year. Click the Enter Cisco Live 365 button in your Cisco Live portal to log in. 84

84

Unified Computing System (UCS) Quality of Service (QoS) and Security. Session ID BRKCOM 2004

Unified Computing System (UCS) Quality of Service (QoS) and Security. Session ID BRKCOM 2004 Unified omputing System (US) Quality of Service (QoS) and Security Session ID BRKOM 2004 US QoS Agenda System omponents QoS hilosophy User onfigurable arameters QoS Tools ongestion Management acket Flow

More information

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Technical Deep Dive: Getting to the Heart of the Matter UCS Technical Deep Dive: Getting to the Heart of the Matter Session ID Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live

More information

UCS Management Deep Dive

UCS Management Deep Dive UCS Management Deep Dive Jeff Silberman UCS Technical Marketing Engineer 2 Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases

More information

Maailman paras palvelinjärjestelmä. Tommi Salli Distinguished Engineer

Maailman paras palvelinjärjestelmä. Tommi Salli Distinguished Engineer Maailman paras palvelinjärjestelmä Tommi Salli Distinguished Engineer Cisco UCS Momentum $1.1B Annualized Run Rate 7,400 UCS Customers; 2,620 repeat customers with average 3.4 repeat buys 350 ATP Channel

More information

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group 2 UCS Bundled Upgrades Useful for Staging, Labs, and Non Productions This does a very quick fast upgrade

More information

UCS Management Deep Dive

UCS Management Deep Dive UCS Management Deep Dive Jason Shaw Cisco UCS Technical Marketing Engineer Agenda Introductions UCS Architecture, Topology Physical Building Blocks Logical Building Blocks Policy Driven Management UCS

More information

LAN Ports and Port Channels

LAN Ports and Port Channels Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,

More information

Statistics Collection Policy Configuration

Statistics Collection Policy Configuration Configuring Statistics Collection Policies, on page 1 Configuring Statistics Threshold Policies, on page 4 Configuring Statistics Collection Policies Statistics Collection Policy A statistics collection

More information

UCS Firmware Management Architecture

UCS Firmware Management Architecture UCS Firmware Management Architecture 2 Legal Disclaimer Many products and features described herein remain in varying stages of development and will be offered on a when-and-ifavailable basis. This roadmap

More information

Next Generation Computing Architectures for Cloud Scale Applications

Next Generation Computing Architectures for Cloud Scale Applications Next Generation Computing Architectures for Cloud Scale Applications Steve McQuerry, CCIE #6108, Manager Technical Marketing #clmel Agenda Introduction Cloud Scale Architectures System Link Technology

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Sarva Chakravarthi Cisco Services UCS LAN Deep Dive - Agenda High-level System Overview Fabric Forwarding Mode of Operations Uplink Pinning Chassis / Fabric Extender Server Connectivity

More information

Evolution with End-to-End Data Center Virtualization

Evolution with End-to-End Data Center Virtualization Evolution with End-to-End Data Center Virtualization Yves Louis DC Virtualisation Technical Solution Architect Agenda Data Center Virtualization Overview Front-End Data Center Virtualization Core Layer

More information

Cisco UCS Network Performance Optimisation and Best Practices for VMware

Cisco UCS Network Performance Optimisation and Best Practices for VMware 1 Cisco UCS Network Performance Optimisation and Best Practices for VMware Chris Dunk Technical Marketing Engineer, Cisco UCS #clmel Agenda Server to Server East West Traffic Flow Architecture Why it is

More information

Equipment Policies. Chassis/FEX Discovery Policy

Equipment Policies. Chassis/FEX Discovery Policy /FEX, page 1 Connectivity, page 6 Rack Server, page 7 Aging Time for the MAC Address Table, page 8 /FEX The chassis/fex discovery policy determines how the system reacts when you add a new chassis or FEX.

More information

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary

More information

UCS Fundamentals Aaron Kerr, Consulting Systems Engineer

UCS Fundamentals Aaron Kerr, Consulting Systems Engineer UCS Fundamentals Aaron Kerr, Consulting Systems Engineer Complementary UCS Sessions Check out www.ciscolive.com for previous session presentations and videos BRKCOM-2003 UCS Networking Deep Dive BRKCOM-2007

More information

NetFlow Monitoring. NetFlow Monitoring

NetFlow Monitoring. NetFlow Monitoring , page 1 NetFlow Limitations, page 2 Creating a Flow Record Definition, page 3 Viewing Flow Record Definitions, page 4 Defining the Exporter Profile, page 4 Creating a Flow Collector, page 5 Creating a

More information

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer UCS Networking Deep Dive Neehal Dass - Customer Support Engineer Agenda Chassis Connectivity Server Connectivity Fabric Forwarding M-Series Q & A Cisco Unified Computing System (UCS) Single Point of Management

More information

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies Expert Reference Series of White Papers Cisco UCS B Series Uplink Strategies 1-800-COURSES www.globalknowledge.com Cisco UCS B Series Uplink Strategies Chris Olsen, Global Knowledge Instructor, Author,

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Steve McQuerry, CCIE # 6108, UCS Technical Marketing @smcquerry 2 UCS LAN Deep Dive Agenda High-level system overview review of different Fabric Interconnects, IOM and Cisco adapters

More information

UCS Engineering Details for the SAN Administrator

UCS Engineering Details for the SAN Administrator UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want

More information

UCS Direct Attached Storage and FC Zoning Configuration Example

UCS Direct Attached Storage and FC Zoning Configuration Example UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.   Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 642-999 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest

More information

UCS deployment guide for Nimble Storage

UCS deployment guide for Nimble Storage Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine

More information

Configuring Priority Flow Control

Configuring Priority Flow Control This chapter contains the following sections: Information About Priority Flow Control, page 1 Guidelines and Limitations, page 2 Default Settings for Priority Flow Control, page 3 Enabling Priority Flow

More information

Congestion Avoidance. Finding Feature Information

Congestion Avoidance. Finding Feature Information This chapter provides information about slow devices that cause congestion (slow-drain devices) in a network and how to avoid slow-drain devices. Finding Feature Information, page 1 Feature History for,

More information

Fabric Failover Scenarios in the Cisco Unified Computing System

Fabric Failover Scenarios in the Cisco Unified Computing System White Paper Fabric Failover Scenarios in the Cisco Unified Computing System What you will Learn Fabric failover is a feature that is unique to the Cisco Unified Computing System (UCS) and is available

More information

Industry Standards for the Exponential Growth of Data Center Bandwidth and Management. Craig W. Carlson

Industry Standards for the Exponential Growth of Data Center Bandwidth and Management. Craig W. Carlson Industry Standards for the Exponential Growth of Data Center Bandwidth and Management Craig W. Carlson 2 Or Finding the Fat Pipe through standards Creative Commons, Flikr User davepaker Overview Part of

More information

Discover 2013 HOL2653

Discover 2013 HOL2653 Discover 2013 HOL2653 HP Virtual Connect 4.01 features and capabilities Steve Mclean and Keenan Sugg June 11 th to 13 th, 2013 AGENDA Schedule Course Introduction [15-20 Minutes] Introductions and opening

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

UCS Networking 201 Deep Dive

UCS Networking 201 Deep Dive UCS Networking 20 Deep Dive BRKCOM-2003 Brad Hedlund bhedlund@cisco.com Manish Tandon mtandon@cisco.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

Traffic Monitoring. Traffic Monitoring

Traffic Monitoring. Traffic Monitoring , page 1 Creating a Session, page 6 Editing an Existing Session, page 7 Activating or Deactivating a Session, page 7 Deleting a Session, page 8 Traffic monitoring copies traffic, from one or more source

More information

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001 UCS Fundamentals Conor Murphy Partner Systems Engineer #clmel Abstract This session provides an introduction to Cisco UCS. It does not assume previous UCS familiarity and is intended as a basic introduction

More information

Programmability of Cisco DC Infrastructure

Programmability of Cisco DC Infrastructure Dubrovnik, Croatia, South East Europe 20-22 May, 2013 Programmability of Cisco DC Infrastructure Ulrich Hamm Sascha Merg 2011 2012 Cisco and/or its affiliates. All rights reserved. Cisco Connect 1 Agenda

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive BRKCOM-2003 www.ciscolivevirtual.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes of the Fabric Interconnect Fabric Failover

More information

HW virtualizace a podpora hypervizorů různých výrobců

HW virtualizace a podpora hypervizorů různých výrobců Cisco Expo 2012 HW virtualizace a podpora hypervizorů různých výrobců René Raeber Datacenter Architect IEEE 802.1DCB Architect Cisco Expo 2012 Cisco and/or its affiliates. All rights reserved. 1 Twitter

More information

You can monitor or use SPAN on port channels only for ingress traffic.

You can monitor or use SPAN on port channels only for ingress traffic. This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session, page 3 Creating a

More information

Techtorial Datová Centra

Techtorial Datová Centra Techtorial Datová Centra Sponsor Sponsor Sponsor Sponsor Logo Logo Logo Logo CIscoEXPO 2010 Cisco Systems, Inc. All rights reserved. Cisco Public 1 Vítejte na DC Techtoriálu 11:00-12:00 UCS deepdive 30"

More information

Overview of Cisco UCS Manager GUI

Overview of Cisco UCS Manager GUI Overview of Cisco UCS Manager GUI This chapter includes the following sections: Overview of Cisco UCS Manager GUI, page 1 Logging in to Cisco UCS Manager GUI through HTTPS, page 6 Logging in to Cisco UCS

More information

Cloud Scale Architectures

Cloud Scale Architectures Next Generation Computing Architectures for Cloud Scale Applications Steve McQuerry, CCIE #6108, Engineering Manager, Technical Marketing James Leach, Principle Engineer, Product Management BRKCOM-2028

More information

UCS Management Architecture Deep Dive

UCS Management Architecture Deep Dive UCS Management Architecture Deep Dive Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live UCS Demo) Programmable Infrastructure

More information

Cisco UCS Virtual Interface Card 1225

Cisco UCS Virtual Interface Card 1225 Data Sheet Cisco UCS Virtual Interface Card 1225 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites compute, networking,

More information

Configuring Network QoS

Configuring Network QoS This chapter describes how to configure a network qos policy for the Cisco NX-OS device in the Data Center Bridging (DCB) network. Note This chapter applies to the F-Series I/O modules only. Finding Feature

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) Cisco Exam Questions 642-999 DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) 1. Which two are true with respect to the unified ports on the Cisco Unified Computing System 62XX Fabric Interconnect?

More information

Introducing Cisco UCS Central 1.3

Introducing Cisco UCS Central 1.3 This chapter includes the following sections: Overview of Cisco UCS Central 1.3 Features, page 1 Overview of Cisco UCS Central 1.3 Features Cisco UCS Central, release 1.3 allows you to take charge of the

More information

Configuring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1

Configuring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1 This chapter includes the following sections:, page 1 SPAN Sources The Switched Port Analyzer (SPAN) feature (sometimes called port mirroring or port monitoring) selects network traffic for analysis by

More information

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001 UCS Fundamentals Conor Murphy Partner Systems Engineer #clmel Abstract This session provides an introduction to Cisco UCS. It does not assume previous UCS familiarity and is intended as a basic introduction

More information

Configuring Priority Flow Control

Configuring Priority Flow Control About Priority Flow Control, on page 1 Licensing Requirements for Priority Flow Control, on page 2 Prerequisites for Priority Flow Control, on page 2 Guidelines and Limitations for Priority Flow Control,

More information

C-Series Jason Shaw, UCS Technical Marketing Steve McQuerry, CCIE # 6108, UCS Technical Marketing

C-Series Jason Shaw, UCS Technical Marketing Steve McQuerry, CCIE # 6108, UCS Technical Marketing C-Series Jason Shaw, UCS Technical Marketing Steve McQuerry, CCIE # 6108, UCS Technical Marketing 2 Agenda C-Series Overview Stand Alone Management UCSM Integration Overview Benefits of B-Series FW Management

More information

UCS IPv6 Management Configuration Example

UCS IPv6 Management Configuration Example UCS IPv6 Management Configuration Example Document ID: 118784 Contributed by Padmanabhan Ramaswamy and Shankar Prasath, Cisco TAC Engineers. Mar 06, 2015 Contents Introduction Prerequisites Requirements

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 3 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2. UCS-ABC Why Firefly Length: 5 Days Format: Lecture/Lab Course Version: 5.0 Product Version: 2.1 This special course focuses on UCS Administration and Troubleshooting UCS Manager 2.0 and provides additional

More information

Cisco Actualtests Questions & Answers

Cisco Actualtests Questions & Answers Cisco Actualtests 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 22.8 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot Cisco

More information

Configuring Priority Flow Control

Configuring Priority Flow Control About Priority Flow Control, page 1 Licensing Requirements for Priority Flow Control, page 2 Prerequisites for Priority Flow Control, page 2 Guidelines and Limitations for Priority Flow Control, page 2

More information

Nexus 7000 F3 or Mx/F2e VDC Migration Use Cases

Nexus 7000 F3 or Mx/F2e VDC Migration Use Cases Nexus 7000 F3 or Mx/F2e VDC Migration Use Cases Anees Mohamed Network Consulting Engineer Session Goal M1 VDC M1/M2 VDC M2/F3 VDC M1/F1 VDC M1/M2/F2e VDC F2/F2e/F3 VDC F2 VDC F3 VDC You are here This Session

More information

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions In Collaboration with Intel May 2015 Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions Presenters: Frank Anderson Desktop Virtualization

More information

Cisco UCS Local Zoning

Cisco UCS Local Zoning Configuration Guide Cisco UCS Local Zoning Configuration Guide May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 30 Contents Overview...

More information

Cisco Data Center Ethernet

Cisco Data Center Ethernet Cisco Data Center Ethernet Q. What is Data Center Ethernet? Is it a product, a protocol, or a solution? A. The Cisco Data Center Ethernet architecture is a collection of Ethernet extensions providing enhancements

More information

Deployment Best Practices for Microsoft Platforms on UCS

Deployment Best Practices for Microsoft Platforms on UCS Deployment Best Practices for Microsoft Platforms on UCS 2 Microsoft Datacentre Applications Increase Agility, Boost Performance, And Reduce Costs Performance Security Manageability Reliability ROI/TCO

More information

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation ETHERNET ENHANCEMENTS FOR STORAGE Sunil Ahluwalia, Intel Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may use

More information

Cisco Nexus B22 Blade Fabric Extender for IBM

Cisco Nexus B22 Blade Fabric Extender for IBM Cisco Nexus B22 Blade Fabric Extender for IBM Design and Deployment Guide 2014 Cisco IBM. All rights reserved. Page 1 Contents Introduction... 3 Network Diagram... 3 Hardware Installation... 5 Fabric Extender

More information

Cisco UCS Virtual Interface Card 1227

Cisco UCS Virtual Interface Card 1227 Data Sheet Cisco UCS Virtual Interface Card 1227 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,

More information

Configuring Port Channels

Configuring Port Channels CHAPTER 5 This chapter describes how to configure port channels and to apply and configure the Link Aggregation Control Protocol (LACP) for more efficient use of port channels in Cisco DCNM. For more information

More information

Cisco UCS Performance Manager

Cisco UCS Performance Manager Data Sheet Cisco UCS Performance Manager Introduction Today s integrated infrastructure data centers must be highly responsive, with heightened levels of flexibility and visibility. Personnel are responsible

More information

Configuring Queuing and Flow Control

Configuring Queuing and Flow Control This chapter contains the following sections: Information About Queues, page 1 Information About Flow Control, page 3 Configuring Queuing, page 4 Configuring Flow Control, page 7 Verifying the Queue and

More information

Overview of Cisco Unified Computing System

Overview of Cisco Unified Computing System Overview of Cisco Unified Computing System This chapter includes the following sections: About Cisco Unified Computing System, page 1 Unified Fabric, page 2 Server Architecture and Connectivity, page 4

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo Vendor: Cisco Exam Code: 642-996 Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo DEMO QUESTION 1 Which three Cisco technologies or solutions are used during the virtualization

More information

Cisco CCIE Data Center Written (Beta) Download Full Version :

Cisco CCIE Data Center Written (Beta) Download Full Version : Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs

More information

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation Errol Roberts, Cisco Systems Inc.

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation Errol Roberts, Cisco Systems Inc. ETHERNET ENHANCEMENTS FOR STORAGE Sunil Ahluwalia, Intel Corporation Errol Roberts, Cisco Systems Inc. SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies

More information

Managing Network Adapters

Managing Network Adapters Managing Network Adapters This chapter includes the following sections: Overview of the Cisco UCS C-Series Network Adapters, page 1 Viewing Network Adapter Properties, page 3 Configuring Network Adapter

More information

PrepAwayExam. High-efficient Exam Materials are the best high pass-rate Exam Dumps

PrepAwayExam.   High-efficient Exam Materials are the best high pass-rate Exam Dumps PrepAwayExam http://www.prepawayexam.com/ High-efficient Exam Materials are the best high pass-rate Exam Dumps Exam : 300-160 Title : Designing Cisco Data Center Unified Computing Vendor : Cisco Version

More information

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture 2012 MELLANOX TECHNOLOGIES 1 SwitchX - Virtual Protocol Interconnect Solutions Server / Compute Switch / Gateway Virtual Protocol Interconnect

More information

Understanding Queuing and Scheduling QoS on Catalyst 4000 Supervisor III and IV

Understanding Queuing and Scheduling QoS on Catalyst 4000 Supervisor III and IV Understanding Queuing and Scheduling QoS on Catalyst 4000 Supervisor III and IV Document ID: 21389 Contents Introduction Before You Begin Conventions Prerequisites Components Used Queuing Strict Priority

More information

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ]

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ] s@lm@n Cisco Exam 642-999 Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ] Question No : 1 HOTSPOT Answer: 2 Explanation: The fabric interconnect b changes from subordinate

More information

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches What You Will Learn The Cisco Unified Computing System helps address today s business challenges by streamlining

More information

Overview. About the Cisco UCS S3260 System

Overview. About the Cisco UCS S3260 System About the Cisco UCS S3260 System, on page 1 How to Use This Guide, on page 3 Cisco UCS S3260 System Architectural, on page 5 Connectivity Matrix, on page 7 Deployment Options, on page 7 Management Through

More information

Borderless Networks. Tom Schepers, Director Systems Engineering

Borderless Networks. Tom Schepers, Director Systems Engineering Borderless Networks Tom Schepers, Director Systems Engineering Agenda Introducing Enterprise Network Architecture Unified Access Cloud Intelligent Network & Unified Services Enterprise Networks in Action

More information

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites

More information

Cisco Next Generation Firewall Services

Cisco Next Generation Firewall Services Toronto,. CA May 30 th, 2013 Cisco Next Generation Firewall Services Eric Kostlan Cisco Technical Marketing 2011 2012 Cisco and/or its affiliates. All rights reserved. Cisco Connect 1 Objectives At the

More information

Configuring Queuing and Flow Control

Configuring Queuing and Flow Control This chapter contains the following sections: Information About Queues, page 1 Information About Flow Control, page 4 Configuring Queuing, page 5 Configuring Flow Control, page 9 Verifying the Queue and

More information

UCS C-Series Deployment Options, Best Practice and UCSM Integration

UCS C-Series Deployment Options, Best Practice and UCSM Integration UCS C-Series Deployment Options, Best Practice and UCSM Integration Steve McQuerry, Manager, Technical Marketing, CCIE #6108 #clmel Agenda Overview and Common Applications C-Series Integration Connectivity

More information

Configuring Enhanced Virtual Port Channels

Configuring Enhanced Virtual Port Channels This chapter contains the following sections: Information About Enhanced vpcs, page 2 Licensing Requirements for Enhanced vpc, page 4 Configuring Enhanced vpcs, page 4 Verifying Enhanced vpcs, page 5 Enhanced

More information

Contents. Introduction. Background Information. Terminology. ACL TCAM Regions

Contents. Introduction. Background Information. Terminology. ACL TCAM Regions Contents Introduction Background Information Terminology ACL TCAM Regions Defaults Nexus 9500 Series TCAM Allocation Nexus 9300 Series TCAM Allocation Configuration Example Scenario Verification Commands

More information

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This

More information

Návrh serverových farem

Návrh serverových farem Návrh serverových farem DCTECH4 Martin Diviš Consulting Systems Engineer mdivis@cisco.com Sponsor Sponsor Sponsor Sponsor Logo Logo Logo Logo CIscoEXPO 1 Agenda Introduction 5k/2k update Basic Concepts

More information

Configuring Link Level Flow Control

Configuring Link Level Flow Control Link Level Flow Control, page 1 Guidelines and Restrictions for Link Level Flow Control, page 1 Information About Link Level Flow Control, page 2 How to Configure Link Level Flow Control, page 3 Configuration

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 4 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

UCS Uplink Ethernet Connection Configuration Example

UCS Uplink Ethernet Connection Configuration Example UCS Uplink Ethernet Connection Configuration Example Document ID: 110267 Contents Introduction Prerequisites Requirements Components Used Conventions Configure Network Diagram 1. Configure Uplink Ethernet

More information

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo Vendor: Cisco Exam Code: 300-160 Exam Name: DCID Designing Cisco Data Center Infrastructure Version: Demo Exam A QUESTION 1 Which three options are features of a Cisco Nexus 7700 Switch? (Choose three.)

More information

UCS Architecture Overview

UCS Architecture Overview UCS Architecture Overview Eric Williams UCS Technical Marketing Engineer Agenda UCS Building Blocks and Connectivity UCS Chassis, Servers, Fabric Interconnects, I/O Modules, Fabric Extenders Service Profiles

More information

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch White Paper Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch Abstract The Cisco midmarket architecture is designed to meet the needs of businesses with

More information

Virtual Networks: For Storage and Data

Virtual Networks: For Storage and Data Virtual Networks: For Storage and Data or Untangling the Virtual Server Spaghetti Pile Howard Marks Chief Scientist hmarks@deepstorage.net Our Agenda Today s Virtual Server I/O problem Why Bandwidth alone

More information

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA)

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA) Course Overview DCAA v1.0 is an extended hours bootcamp class designed to convey the knowledge necessary to understand and work with Cisco data center technologies. Covering the architecture, components

More information

Introducing Cisco UCS Central 1.4

Introducing Cisco UCS Central 1.4 This chapter includes the following sections: Overview of Cisco UCS Central 1.4 Features, page 1 Behavior and Design Changes in HTML5 UI, page 10 Multi-version Management Support, page 11 Feature Support

More information