37.3. Pushbuttons and Indicating Lights. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description
|
|
- Annabelle Joy French
- 6 years ago
- Views:
Transcription
1 .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Description Page Features V7-T-15 Product Selection M22 Assembled Control Stations V7-T-16 Commercial Control Stations V7-T-17 General Purpose Control Stations V7-T-18 Special Purpose Control Stations V7-T H Series Heavy-Duty Control Stations V7-T T Series Heavy-Duty 30.5 mm Control Stations V7-T-21 Class I Division T Series Heavy-Duty 30.5 mm Control Stations V7-T-22 Class I Division 2 E34 Series Corrosion Resistant 30.5 mm Control Stations.... V7-T-23 Accessories V7-T-23 Custom Assembled Stations Specification Form V7-T-24 Renewal Parts V7-T-26 Technical Data and Specifications V7-T-28 Dimensions V7-T-28 Product Description M22 Assembled Control Stations M22 series operators Available in horizontal and vertical configurations Impact resistant polycarbonate enclosures Optional yellow covers Base mounting contact blocks and light units for quick wiring and vibration resistance Commercial Control Stations 10250T series operators Full front label Specific function labels on front of enclosure General Purpose Control Stations Construction grade General purpose wall mount Popular with contractors UL (NEMA) Type 1 Special Purpose Control Stations Standard grade Polyester enclosure UL (NEMA) Type 3, 3R, 4, 4X, H Series Heavy-Duty Control Stations 10250H Series operators Dark brown polyester enclosure Protective rubber gaskets provide NEMA 3S rating on s Top and bottom 3/4 in NPT conduit entrances Includes alternate legend plates and spare mounting screws 10250T Series Heavy-Duty 30.5 mm Control Stations 10250T Series operators ASA 61 gray die-cast zinc enclosures Surface or flush mounting Single 3/4 in NPT conduit entrance on one and two element stations Single 1 in NPT conduit entrance on three element stations Class I Division T Series Heavy-Duty 30.5 mm Control Stations 10250T Series operators Factory sealed contact blocks Die-cast, polyester or stainless steel enclosures Approved for NEC Class I Division 2, Groups B, C and D or Class I Zone 2 Group IIB plus Hydrogen type hazardous locations Class I Division 2 E34 Series Corrosion Resistant 30.5 mm Control Stations E34 Series operators Factory sealed contact blocks Die-cast, polyester or stainless steel enclosures Approved for NEC Class I Division 2 Groups B, C and D or Class I Zone 2 Group IIB plus Hydrogen type hazardous locations V7-T-14 Volume 7 Motor Controls, Logic and Connectivity CA E April
2 Pushbuttons and Indicating Lights.3 Features M22 Assembled Control Stations IP66, UL (NEMA) Type 4X, 13 Impact resistant polycarbonate enclosures Optional yellow cover 25% smaller depth than most competitor enclosures Base mounting contact blocks and light units for faster wiring and vibration resistance Commercial Control Stations ASA 61 gray die-cast zinc enclosures Pre-assembled and labeled for functions such as Fuel Shut-Off Great for commercial applications General Purpose Control Stations Construction grade General purpose wall mount Popular with contractors UL (NEMA) Type 1 Special Purpose Control Stations Standard grade Polyester enclosure UL (NEMA) Type 3, 3R, 4, 4X, H Series Heavy-Duty Control Stations Industrial grade Extra heavy-duty Polyester enclosure Booted buttons Outdoor installation UL (NEMA) Type 3, 3R, 3S, 4, 4X, 12, T Series Heavy-Duty 30.5 mm Control Stations 30.5 mm operators Industrial grade Zinc die cast enclosure Popular with industrial end users UL (NEMA) Type 4, 4X, 12, 13 Class I Division 2 Control Stations Available with 10250T or E mm operators Zinc die cast, polyester or stainless steel enclosures Factory-sealed contact blocks Popular with industrial end users UL (NEMA) Type 4, 4X, 12, 13 NEC Class I Division 2 Groups B, C and D Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-15
3 .3 Pushbuttons and Indicating Lights Product Selection M22 Assembled Control Stations One Element Control Stations Orientation Description Color Inscription Two Element Control Stations Three Element Control Stations Notes For assembled control stations not found in this selection, please contact the Eaton Technical Resource Center at ETN CARE ( ) or Contact block configuration. Enclosure Cover Color Horizontal 40 mm mushroom head push-pull emergency stop operator Red NC Yellow M22-C1-M1H Horizontal 40 mm illuminated mushroom head push-pull emergency stop operator, Vac Red NO-NC Yellow M22-C1-M2H Horizontal 40 mm mushroom head twist-to-release emergency stop operator Red NC Yellow M22-C1-M3H Horizontal 40 mm mushroom head key-release emergency stop operator Red NC Yellow M22-C1-M4H Horizontal Flush Green NO Gray M22-C1-M5H Horizontal Flush Green NO START Gray M22-C1-M6H Horizontal Extended Red NC Gray M22-C1-M7H Horizontal Extended Red NC STOP Gray M22-C1-M8H Horizontal Key-operated selector switch, two-position maintained NO OFF-ON Gray M22-C1-M9H Horizontal Knob type selector switch, three-position maintained 2NO HAND 0 AUTO Gray M22-C1-M10H Horizontal Double Green NO START Gray M22-C1-M11H Orientation Element 1 Description Color Inscription Red NC STOP Element 2 Description Color Inscription Enclosure Cover Color Horizontal Extended Red NC Flush Green NO Gray M22-C2-M1H Vertical Flush Green NO START Extended Red NC STOP Gray M22-C2-M2V Vertical Flush Black NO FORWARD Flush Black NO REVERSE Gray M22-C2-M3V Orientation Horizontal Vertical Horizontal Vertical Vertical Vertical Element 1 Description Color Inscription Extended Indicating light Flush Flush Flush Flush Red NC Indicating light White Vac Flush Green NO Extended Black NO OPEN Extended Black NO FORWARD Flush Black NO UP Flush Element 2 Description Color Inscription White Vac Flush Green NO START Extended Red NC Flush Red NC STOP Flush Red NC STOP Flush Red NC STOP Flush Element 3 Description Color Inscription Enclosure Cover Color Green NO Gray M22-C3-M1H Red NC STOP Gray M22-C3-M2V Green NO Gray M22-C3-M3H Black NO CLOSE Gray M22-C3-M4V Black NO REVERSE Gray M22-C3-M5V Black NO DOWN Gray M22-C3-M6V V7-T-16 Volume 7 Motor Controls, Logic and Connectivity CA E April
4 Pushbuttons and Indicating Lights.3 Commercial Control Stations Key Specifications 30.5 mm (10250T series) operators ASA 61 gray die-cast zinc enclosures Industrial grade UL Type 4, 4X, 12, 13 Single 3/4 in NPT conduit entrance Dimensions in (mm) Enclosure: 3.88 W x 4.00 H x 3.00 D (98.6 x x 76.3) Operator: 1.63 D (to enclosure) x 1.50 diameter (41.4 x 38.1) What is included? Eaton s pre-assembled, enclosed emergency stop stations include an operator, an enclosure, contact blocks and a variety of unique labels. Each label has white lettering on a red background indicating the function and red lettering on a white background indicating the operator type. Available s Catalog Number Operator Additional Contact Blocks (Sold Separately) Note Includes 1NO-1NC contact block. Enclosure Color Label 10250T5B62-S101 Pushbutton Gray EMERGENCY STOP 10250T5B62-S102 Pushbutton Gray EMERGENCY SHUT-OFF 10250T5B62-S103 Pushbutton Gray EMERGENCY GENERATOR STOP 10250T5B62-S104 Pushbutton Gray EMERGENCY HVAC SHUT-DOWN 10250T5B62-S105 Pushbutton Gray EMERGENCY ELECTRICAL DISCONNECT 10250T5B62-S106 Pushbutton Gray EMERGENCY BOILER SHUT-DOWN 10250T5B62-S107 Pushbutton Gray EMERGENCY CHILLER STOP 10250T5B62-S108 Pushbutton Gray EMERGENCY FUEL SHUT-OFF 10250T5B62-S109 Pushbutton Gray EMERGENCY REFRIGERATION STOP 10250T5B62-S110 Pushbutton Gray EMERGENCY POWER OFF 10250T5B62-S111 Pushbutton Gray EMERGENCY GAS SHUT-OFF 10250T5B62-S121 Pushbutton Gray EMERGENCY VENTILATION SHUT-DOWN 10250T5B62-S131 Pushbutton Gray GENERATOR 10250T T T T T2 Circuit Configuration 1NC 1NO NO-NC 2NC 2NO Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-17
5 .3 Pushbuttons and Indicating Lights General Purpose Control Stations Single Button Station with Padlock Attachment Accessory Selector Switch Two Button Station Three Button Station Three Button Station with Indicating Light Type N Control Stations UL (NEMA) Type 1 Contact Symbol Button Type/Color Legends One Element Enclosure Type Note Round button. Flush/green START 10250H5100 Flush/red STOP 10250H5101 Extended/red STOP 10250H5104 Palm operated/black None 10250H89 Three-position selector switch/black knob Two Element Enclosure Type RUN/OFF/AUTO 10250H289 Flush/red START/STOP 10250H5200 Flush/green extended/red Three Element Enclosure Type START/STOP 10250H5207 Flush/black (all) RAISE/LOWER 10250H5201 FOR/REV OPEN/CLOSE UP/DOWN HIGH/LOW FAST/SLOW 10250H H H H H5208 Flush/black (all) FOR/REV/STOP 10250H5300 UP/DOWN/STOP RAISE/LOWER/STOP OPEN/CLOSE/STOP FAST/SLOW/STOP 110/220V neon indicating light START/STOP Clear flush/green; flush/red Red flush/green; flush/red Amber flush/green; flush/red 10250H H H H H ED ED853-2 V7-T-18 Volume 7 Motor Controls, Logic and Connectivity CA E April
6 Pushbuttons and Indicating Lights.3 Selector Switch Two Button Station Mechanically Interlocked Pushbuttons Special Purpose Control Stations 10250H_ 10250H_ Type N Control Stations Open Type Construction (No Cover) Contact Symbol Button Type/Color Legends One Element Enclosure Type Two Element Enclosure Type Special Purpose Control Stations UL (NEMA) Type 3, 3R, 4, 4X, 13 Note Three-position selector switch/black knob No legend on buttons. Specify any standard legend. RUN/OFF/AUTO 10250H2538 Flush/green START/STOP 10250H2747 Flush/black (all) mech. interlocked None 10250H2544 Contact Symbol Feature Legends One Element Pushbutton Type Two Element Pushbutton Type Flush START 10250H2738 STOP 10250H658 With lock hasp STOP 10250H665 Flush START/STOP 10250H364 With lock hasp START/STOP 10250H671 Buttons interlocked FAST/SLOW 10250ED664 FOR/REV UP/DOWN OPEN/CLOSE 10250H H H2742 Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-19
7 .3 Pushbuttons and Indicating Lights 10250H Series Heavy-Duty Control Stations 10250H_ 10250H_ 10250H_ Type H Control Stations UL (NEMA) Type 3, 3S, 4, 4X, 12, 13 Element Type Feature Circuit One Element Assembled Legend Plate Unassembled Alternate Legend Plate Pushbuttons Without padlock hasp 1NO-1NC JOG START 10250H1881 Knob selector switch Two Element With padlock hasp 1NC STOP 10250H4239 Two-position 1NO-1NC OFF/ON 10250H4526 Three-position 1NO-1NC MAN/OFF/AUTO 10250H4527 Pushbuttons Standard 1NO-2NC START/STOP 10250H1884 Three Element Standard and standard with padlock hasp STOP 2NO-2NC RAISE/LOWER FORWARD 10250H1885 RUN REVERSE OPEN CLOSE 1NO-2NC START/STOP 10250H4240 Pushbuttons Standard 2NO-3NC FOR/REV/STOP START OPEN 10250H1890 Indicating light and s 120V Two standard and standard with padlock hasp Light-red lens and two plain 1NO-2NC MOTOR RUNNING START/STOP JOG CLOSE 10250H4241 RAISE LOWER FAST SLOW 10250H1913 V7-T-20 Volume 7 Motor Controls, Logic and Connectivity CA E April
8 Pushbuttons and Indicating Lights T Series Heavy-Duty 30.5 mm Control Stations Break Glass Station One Element Two Element Three Element Break Glass Operator Complete Assembled Stations UL (NEMA) Type 4, 4X, 12, 13 Element Type Break Glass Station Break Glass Kit Notes Features Contact Block(s) Legend Stop buttons are red all others are black. NEMA 4 13, if properly mounted on a flat surface. Consists of front plate, legend, operator and contact blocks. Breaking glass closes contact. Lock is 10250TA2. Uses deep cover instead of shallow cover. Switch component is 10250TA67. Shown assembled to contact block (contact block supplied separately). Surface Mounting Break glass station Gray enclosure NC (logic level) EMERG. OFF 10250TGS One Element Red enclosure 10250TGR Flush Mounting Pushbutton Standard NO-NC START 10250T T3573 Selector switch Push-pull three-position Two Element NC STOP 10250T T3575 NO-NC None 10250T T3597 Mushroom head NO-NC START 10250T T3574 NC STOP 10250T T3576 With lock hasp NC STOP 10250T T3577 Two-position black knob Three-position black knob Momentary red button NO-NC OFF/ON 10250T T3580 2NO MAN/OFF/AUTO 10250T T3581 2NC START/STOP 10250T T3602 Pushbuttons Standard 1NO-2NC START/STOP 10250T T3582 Three Element 2NO-2NC RAISE/LOWER 10250T T3673 2NO-2NC None 10250T T3598 With lock hasp 1NO-2NC START/STOP 10250T T3599 Standard and mushroom head 1NO-2NC START/STOP 10250T T3583 Standard with NO-NC START/STOP 10250T T3585 maintained contact Plus NC Pushbuttons Standard 2NO-3NC FOR, REV, STOP 10250T T3589 Indicating light (transformer type) and s Description Operator with hammer and five glass discs Glass discs only (5) 2NO-3NC UP, DOWN, STOP 10250T3615 2NO-3NC OPEN, CLOSE, STOP 10250T3614 2NO-3NC None, None, STOP 10250T T3600 Two standard and with lock hasp 2NO-3NC None, None, STOP 10250T T3601 Red lens 120V 1NO-2NC MOTOR RUN, 10250T T3593 Red lens 240V START/STOP 10250T T3594 Red lens 480V 10250T T3595 Red lens 600V 10250T T TBG 10250TGL Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-21
9 .3 Pushbuttons and Indicating Lights Class I Division T Series Heavy-Duty 30.5 mm Control Stations 10250T T7023P 10250T7033S Complete Assembled Stations UL (NEMA) Type 4, 4X, 12, 13; NEC Class I Division 2, Groups B, C and D Contact Symbol Single Pushbutton 1NO 1NC Two Pushbuttons 1NO 1NC Each Button Button Type/Color Legend Marking Die Cast Enclosure Polyester Molded Enclosure Stainless Steel Enclosure Flush/green START 10250T T7003P 10250T7003S Extended/red STOP 10250T T7005P 10250T7005S Alum. jumbo mushroom/red EMER. STOP (engraved button) 10250T T7007P 10250T7007S Flush/black No legend 10250T T7009P 10250T7009S Flush/green START 10250T T7023P 10250T7023S Extended/red STOP Flush/black No legend 10250T T7025P 10250T7025S Flush/black Single Pilot Light Two Pushbuttons 1NC Each Button No legend 120 Vac red No legend 10250T T7033P 10250T7033S Flush/green Extended/red START STOP 120 Vac red No legend 10250T T7035P 10250T7035S Flush/black Flush/black Three-Position Selector Switch Maintained knob/black Maintained knob/black Single Pushbutton Maintained Pull O X 1NO 2NO 2NC Push X 1NO O 1NC Push-pull with jumbo mushroom/red HAND/OFF/AUTO 10250T T7011P 10250T7011S No legend 10250T T7013P 10250T7013S EMER. STOP (engraved button) 10250T T7019P 10250T7019S V7-T-22 Volume 7 Motor Controls, Logic and Connectivity CA E April
10 Pushbuttons and Indicating Lights.3 Class I Division 2 E34 Series Corrosion Resistant 30.5 mm Control Stations E34EX_ Accessories Padlock Attachment Complete Assembled Stations UL (NEMA) Type 4, 4X, 12, 13; NEC Class I Division 2, Groups B, C and D Contact Symbol Single Pushbutton 1NO 1NC Two Pushbuttons 1NC Each Button Button Type/Color Type N Control Stations Legend Marking Note Use NEMA 4X 10250T operators where exposed to ultraviolet light, see Page V7-T-22. Die Cast Enclosure Polyester Molded Enclosure Stainless Steel Enclosure Flush/green START E34EX7003 E34EX7003P E34EX7003S Extended/red STOP E34EX7005 E34EX7005P E34EX7005S Alum. jumbo mushroom/red EMER. STOP (engraved button) E34EX7007 E34EX7007P E34EX7007S Flush/black No legend E34EX7009 E34EX7009P E34EX7009S Flush/green START E34EX7023 E34EX7023P E34EX7023S Extended/red STOP Flush/black No legend E34EX7025 E34EX7025P E34EX7025S Flush/black Three-Position Selector Switch Maintained knob/black Maintained knob/black Single Pushbutton Maintained Pull O X 1NO Description 2NO 2NC Push X 1NO O 1NC Push-pull with jumbo mushroom/red Padlock attachment For field assembly on square button type (except extended button types) No legend HAND/OFF/AUTO E34EX7011 E34EX7011P E34EX7011S No legend E34EX7013 E34EX7013P E34EX7013S EMER. STOP (engraved button) E34EX7019 E34EX7019P E34EX7019S 10250H5110 Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-23
11 .3 Pushbuttons and Indicating Lights Custom Assembled Stations Specification Form Ordering Instructions Step 1 Copy this ordering guide from catalog. Step 2 Specify 10250T or E34 lines in the corresponding box on the following page T E34 Pages V7-T-167 V7-T-239 Pages V7-T-240 V7-T T and Pages E34 V7-T-307 V7-T-347 Class I Div. 2 Step 3 Check back of panel dimensions specify single or double depth enclosure in the corresponding box on the following page. Step 4 Specify enclosure catalog number and price in the corresponding box on the following page. Enclosures can be found on Pages V7-T-101, V7-T-219 and V7-T-269. For pricing, reference the most recent PAD or VISTA-line. Step 5 Specify catalog numbers for desired operator, legend plate, light unit, accessory and contact block(s) for each location in the enclosure in the corresponding box on the following page. (See position locations on this page.) Position 1 Position 1 Position 2 Position 1 Position 2 Position 3 Position 1 Position 2 Position 3 Position 4 Position Locations Step 6 For non-standard legends, specify legend desired, letter size and location on the layout sketches on the following page. For limitations see Page V7-T-218. For pricing, use the blank legend catalog number and STAMP Suffix (Ex.: 10250TS36STAMP) and reference the most recent PAD or VISTA-line. Example: 10250TS36 Special Legend for Position # LETTER SIZE 3/32 in 1/8 in 3/16 in Step 7 Fax Sheet 2 of this form to Eaton s TRC, Technical Resource Center, at to the attention of Custom Stations Order or to TRC@eaton.com. Within a few days you will receive a confirmation fax with the custom station part number and price. Step 8 Place your order over the VISTA System. For Selector and Roto-Push Operators 10250T or E34 For single contact blocks or 1NO-1NC contact blocks, the mounting position of contacts must be specified. For example: If a 1NO-1NC contact block is required, specify if NO is to be mounted in Top A position or Bottom B position. V7-T-24 Volume 7 Motor Controls, Logic and Connectivity CA E April
12 Pushbuttons and Indicating Lights.3 To Step 2) 10250T STD Class I Division 2 E34 STD Class I Division 2 Step 5) Position Position Eaton s TRC, Custom Station Order (828) FAX, or to TRC@eaton.com From Customer Name Customer Contact Phone Number Fax Number Address Operator Legend Plate Price U.S. $ Light Unit Price U.S. $ Step 3) Single Depth Enclosure Double Depth Enclosure Contact Block Part Number Product Code Suffix Date Engineer Price U.S. $ A/L B/R Contact Block FACTORY USE ONLY Step 4) Enclosure Price U.S. $ A/L B/R Step 6) Non-standard Legends Special Legend for Position # Special Legend for Position # Special Legend for Position # LETTER SIZE 3/32 inch (2.4 mm) 1/8 inch (3.2 mm) 3/16 inch (4.8 mm) Price U.S. $ Lens or Caps LETTER SIZE 3/32 inch (2.4 mm) 1/8 inch (3.2 mm) 3/16 inch (4.8 mm) Price U.S. $ Accessory Price U.S. $ 10% Adder for Assembled Stations LETTER SIZE 3/32 inch (2.4 mm) 1/8 inch (3.2 mm) 3/16 inch (4.8 mm) Total Price Total: Price Total Price Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-25
13 .3 Pushbuttons and Indicating Lights Renewal Parts Type N Renewal Parts Assembled Stations Type N Item No. Description Type N Square Buttons 1 Cover 1 No. Req. Part Number Two element One element top button One element bottom button Cover screw Pushbutton support bracket Pushbutton support bracket screw Pushbutton spring Disc (when used two element assembly) Pushbutton top position 1 START/green RAISE/black FORWARD/black OPEN/black UP/blank Blank/green Pushbutton bottom position 1 STOP/red Extended STOP/red REVERSE/black CLOSE/black DOWN/black LOWER/black Blank/red Item No. Description Type N Square Buttons, continued 9 Pushbutton element 1 No. Req. Part Number 1NO-1NC NO NO NC Cover Pushbutton support bracket Pushbutton top position 1 FORWARD/black UP/black RAISE/black OPEN/black FAST/black Pushbutton middle position 1 REVERSE/black DOWN/black LOWER/black CLOSE/black SLOW/black Pushbutton bottom position 1 STOP/red Pushbutton element 1 2NO-3NC Cover V7-T-26 Volume 7 Motor Controls, Logic and Connectivity CA E April
14 Pushbuttons and Indicating Lights.3 Assembled Stations Type N, continued Item No. Description Type N Square Buttons, continued 17 Lens 1 Type H Renewal Parts Assembled Stations Type H No. Req. Part Number Clear Red Amber Shield Shield screws Lamp (neon NE48) Lamp receptacle Lamp receptacle screw F1 23 Pilot light terminal base Lens 1 Clear Red Amber Pushbutton support bracket Pushbutton element Item No. 1NO-1NC Pushbutton Description Type H Assembled Stations No. Req. 7 Part Number 1 Screw Screw Base Contact blocks See Page V7-T T operator See Pages V7-T-174 V7-T Mounting plate Item No. Description Type N Round Buttons Similar to 27 Pushbutton assembly and element for: No. Req. Part Number 10250H H H H H H H H H H Indicating Light Selector Switch Item No. Description Type H Assembled Stations No. Req Part Number 7 Screw Diaphragm Mounting plate Gasket Base Mounting plate Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-27
15 .3 Pushbuttons and Indicating Lights Technical Data and Specifications Ratings Maximum Ampere Ratings for Type N Control Stations Maximum Ampere Ratings for Type H Control Stations Dimensions Approximate Dimensions in Inches (mm) Type N Control Stations Special Purpose Control Stations Note 2.38 (60.5) for neon indicating light. Volts AC Volts DC Description Make and emergency interrupt capacity Normal load break Continuous current Description Volts AC 50/60 Hz Volts DC Make and emergency interrupt capacity Normal load break Continuous amperes Voltamperes Make and emergency interrupt capacity Normal load break (38.1) 2.25 (57.2) 4.00 (101.6) 3.25 (82.6) 2.25 (57.2) Single Button Station 2.25 (57.2) 3.13 (79.5) 5.50 (139.7) 0.75 (19.1) Pipe Tap 6.25 (158.8) 1.50 (38.1) 2.25 (57.2) Ship Wt. 2.5 Lb (1.1 kg) 4.00 (101.6) 3.25 (82.6) Two Button Station 3.38 (85.9) 2.25 (57.2) 1.50 (38.1) 2.25 (57.2) 6.00 (152.4) 5.00 (127.0) Three Button Station 2.25 (57.2) V7-T-28 Volume 7 Motor Controls, Logic and Connectivity CA E April
16 Pushbuttons and Indicating Lights.3 Approximate Dimensions in Inches (mm) Type H Control Stations NEMA Type 3, 3R, 3S, 4, 4X, 13 No. of Elements 10250T and E34 Dimensions Wide High Deep 1 and (114.3) 8.25 (209.6) 4.50 (114.3) (114.3) (273.1) 4.25 (108.0) Approximate Enclosure Dimensions Number of Elements Cast Surface Mounting Dimensions in In (mm) Wide A (98.6) (98.6) (98.6) (98.6) Polyester (96.8) (96.8) (96.8) (96.8) Stainless Steel (76.2) (88.9) (88.9) (88.9) High B 4.0 (101.6) 5.88 (149.4) 7.75 (196.9) 9.63 (244.6) 6.63 (168.4) 6.63 (168.4) 8.88 (225.6) 6.63 (168.4) 3.50 (88.9) 6.75 (171.5) 9.00 (228.6) (285.8) Deep C 3.0 (76.3) 3.0 (76.3) 3.0 (76.3) 3.0 (76.3) 3.38 (85.9) 3.38 (85.9) 3.38 (85.9) 3.38 (85.9) 3.00 (76.2) 3.00 (76.2) 3.00 (76.2) 3.00 (76.2) Note No conduit entrance holes provided. Drill as required. Mounting D 2.69 (68.3) 2.69 (68.3) 2.69 (68.3) 2.69 (68.3) 2.94 (74.7) 2.94 (74.7) 2.94 (74.7) 2.94 (74.7) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) E 3.25 (82.6) 5.13 (130.3) 7.0 (177.8) 8.88 (225.6) 4.88 (124.0) 4.88 (124.0) 7.13 (181.1) 4.88 (124.0) 4.25 (108.0) 7.50 (190.5) 9.00 (228.6) (304.8) Conduit Entrance 3/4 3/ Mtg. Holes Screw Size for 1 4 Element Die Cast/ Stainless Steel Enclosure 7/32 Screw Size for Polyester D A E B Surface C Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T-29
17 Index A AC, 15 Accessories, 1, 10 Accessory, 5, 12 accessory, 11 Adder, 12 Additional, 4 Address, 12 all, 5-6, 8 alternate, 1 AlternateElement, 7 Alum, 9-10 Amber, 5, 14 Ampere, 15 amperes, 15 an, 4 and, 1-16 any, 6 applications, 2 Approved, 1 Approximate, April, 1-16 are, 8 as, 2, 16 ASA, 1-2, 4 Assembled, 1-16 assembled, 2-4, 8 assembly, 10, at, 1-16 Attachment, 5, 10 attachment, 10 attention, 11 AUTO, 3, 5-10 Available, 1-2, 4 B back, 11 background, 4 Base, 1-2, 14 base, 14 be, 11 Black, 3 black, 5-6, 8-10, 13 Blank, 13 blank, 11, 13 Block, 8, 12 block, 3-4, 8, 11 Blocks, 4 blocks, 1-2, 4, 8, 11, 14 BOILER, 4 Booted, 2 Bottom, 11 bottom, 1, 13 box, 11 bracket, Break, 8 break, 15 Breaking, 8 brown, 1 Button, 5-6, 9-10, 15
18 Index button, 5, 8-10, 13 Buttons, 6, buttons, 2, 6, 8 C CA, 1-16 call, 1-16 can, 11 capacity, 15 Caps, 12 CARE, 3 Cast, 9-10, 16 cast, 1-2, 4 Catalog, 3-10, 12 catalog, 11 Center, 3, 11 Check, 11 CHILLER, 4 Circuit, 4, 7 Class, 1-2, 9-12 Clear, 5, 14 CLOSE, 3, 5-8, 13 closes, 8 CLOSEStandard, 7 Code, 12 Color, 3-6, 9-10 com, 1-16 Commercial, 1-2, 4 commercial, 2 competitor, 2 Complete, 8-10 component, 8 Conduit, 16 conduit, 1, 4, 16 Configuration, 4 configuration, 3 configurations, 1 confirmation, 11 Connectivity, 1-16 Consists, 8 Construction, 1-2, 6 Contact, 3-6, 8-10, 12, 14 contact, 1-4, 8, 11 contacts, 11 Contents, 1 continued, Continuous, 15 contractors, 1-2 Control, 1-16 control, 3 Controls, 1-16 Copy, 11 corresponding, 11 Corrosion, 1, 10 Cover, 3, 6, 13 cover, 2, 8 covers, 1 current, 15 Custom, 1, custom, 11 Customer, 12 D Dark, 1 Data, 1, 15 Date, 12 days, 11 DC, 15 Deep, 16 deep, 8 Delivery, 1-16 Depth, 12 depth, 2, 11 Description, 1, 3, 8, 10, desired, 11 diameter, 4 Diaphragm, 14 Die, 1, 9-10, 16 die, 1-2, 4 Dimensions, 1, 4, dimensions, 11 Disc, 13 DISCONNECT, 4 discs, 8 Div, 11 Division, 1-2, 9-10, 12 Double, 3, 12 double, 11 DOWN, 3-6, 8, 13 Drill, 16 Duty, 1-2, 7-9 duty, 2
19 Index E Each, 4, 9-10 each, 11 Eaton, 3-4, eaton, 1-16 ED, 5-6 ELECTRICAL, 4 Element, 3, 5-8, 16 element, 1, ElementPushbuttons, 7 Elements, 16 , 12 , EMER, 9-10 EMERG, 8 EMERGENCY, 4 emergency, 3-4, 15 enclosed, 4 Enclosure, 3-6, 9-10, 12, 16 enclosure, 1-2, 4, 8, 11 Enclosures, 11 enclosures, 1-2, 4 end, 2 Engineer, 12 engraved, 9-10 Entrance, 16 entrance, 1, 4, 16 entrances, 1 ETN, 3 EX, 10 Ex, 11 Example, 11 example, 11 except, 10 exposed, 10 Extended, 3, 5, 9-10, 13 extended, 5, 10 Extra, 2 F FACTORY, 12 Factory, 1-2 FAST, 5-7, 13 faster, 2 Fax, fax, 11 Feature, 6-7 Features, 1-2, 8 few, 11 field, 10 five, 8 flat, 8 Flush, 3, 5-6, 8-10 flush, 1, 5 following, 11 FOR, 5-8 For, 1-16 for, 1-2, 11-12, Form, 1, 11 form, 11 FORWARD, 3, 7, 13 found, 3, 11 From, 12 from, 11 front, 1, 8 FUEL, 4 Fuel, 2 Full, 1 function, 1, 4 functions, 2 G GAS, 4 Gasket, 14 gaskets, 1 General, 1-2, 5 GENERATOR, 4 Glass, 8 glass, 8 grade, 1-2, 4 Gray, 3-4, 8 gray, 1-2, 4 Great, 2 Green, 3 green, 5-6, 9-10, 13 Group, 1 Groups, 1-2, 9-10 guide, 11
20 Index H hammer, 8 HAND, 3, 9-10 has, 4 hasp, 6-8 hazardous, 1 head, 3, 8 Heavy, 1-2, 7-9 heavy, 2 HIGH, 5 High, 16 Holes, 16 holes, 16 Horizontal, 3 horizontal, 1 H, 3 HVAC, 4 Hydrogen, 1 Hz, 15 I If, 11 if, 8, 11 IIB, 1 illuminated, 3 Immediate, 1-16 Impact, 1-2 In, 16 in, 1, 3-4, 11, inch, 12 Inches, include, 4 included, 4 Includes, 1, 4 Indicating, 1-16 indicating, 4-5, 15 Industrial, 2, 4 industrial, 2 Inscription, 3 installation, 2 instead, 8 Instructions, 11 Interlocked, 6 interlocked, 6 interrupt, 15 IP, 2 is, 4, 8, 11 Item, J JOG, 7 jumbo, 9-10 K Key, 3-4 key, 3 kg, 15 Kit, 8 KMParts, 1-16 Knob, 3, 7 knob, 5-6, 8-10 L Label, 4 label, 1, 4 labeled, 2 labels, 1, 4 Lamp, 14 layout, 11 Lb, 15 Legend, 7-12 legend, 1, 6, 8-11 Legends, 5-6, 12 legends, 11 Lens, 12, 14 lens, 7-8 LETTER, letter, 11 lettering, 4 level, 8
21 Index Light, 5, 7, 9, 12, 14 light, 1-3, 5, 7-8, 10-11, Lights, 1-16 limitations, 11 line, 11 lines, 11 load, 15 location, 11 Locations, 11 locations, 1, 11 Lock, 8 lock, 6, 8 Logic, 1-16 logic, 8 LOW, 5 LOWER, 5, 7-8, 13 M Maintained, 9-10 maintained, 3, 8 Make, 15 MAN, 7-8 Marking, 9-10 Maximum, 15 mech, 6 Mechanically, 6 middle, 13 mm, 1-4, 8-10, 12, Molded, 9-10 Momentary, 8 most, 2, 11 MOTOR, 7-8 Motor, 1-16 mount, 1-2 mounted, 8, 11 Mounting, 8, 14, 16 mounting, 1-2, 11 Mtg, 16 Mushroom, 8 mushroom, 3, 8-10 must, 11 N Name, 12 NC, 3-4, 7-11, NE, 14 NEC, 1-2, 9-10 NEMA, 1-2, 5-10, 16 neon, 5, NO, 3-4, 7-11, No, 6, 9-10, 13-14, 16 Non, 12 non, 11 None, 5-6, 8 Normal, 15 not, 3 Note, 4-6, 10, Notes, 3, 8 NPT, 1, 4 Number, 3-4, 6-10, 12-14, 16 number, 11 Numbers, 4 numbers, 11 NumberSingle, 5 O of, 1, 4, 8, 11, 16 OFF, 3-10 Off, 2 ON, 3, 7-8 on, 1, 4, 6, 8, One, 3, 5-8, 13 one, 1 only, 8 ONLYAX, 12 OPEN, 3, 5-8, 13 Open, 6 operated, 3, 5 Operator, 4, 8, 12 operator, 3-4, 8, 11, 14 Operators, 11 operators, 1-2, 4, 10 Optional, 1-2 or, 1-16 Order, order, 11
22 Index Ordering, 11 ordering, 11 Orientation, 3 others, 8 Outdoor, 2 over, 11 P PAD, 11 Padlock, 5, 10 padlock, 7 Page, 1, 10-11, 14 page, 11 Pages, 11, 14 Palm, 5 panel, 11 Part, part, 11 Parts, 1, Phone, 12 Pilot, 9, 14 Pipe, 15 Place, 11 plain, 7 Plate, 7, 12 plate, 8, 11, 14 plates, 1 please, 3 Plus, 8 plus, 1 polycarbonate, 1-2 Polyester, 1-2, 9-10, 16 polyester, 1-2 Popular, 1-2 Positio, 11 Position, 9-12 position, 3, 5-8, 11, 13 POWER, 4 Pre, 2 pre, 4 Price, 12 price, 11 pricing, 11 Product, 1, 3, 12 properly, 8 Protective, 1 provide, 1 provided, 16 Pull, 9-10 pull, 3, 8-10 Purpose, 1-2, 5-6, 15 purpose, 1-2 Push, 8-11 push, 3 Pushbutton, 1-16, 3-4, 11 Pushbuttons, 1-16 s, 1, 8 Q quick, 1 R RAISE, 5, 7-8, 13 rating, 1 Ratings, 15 receive, 11 recent, 11 receptacle, 14 Red, 3, 5, 8, 14 red, 4-5, 7-10, 13 reference, 11 REFRIGERATION, 4 release, 3 Renewal, 1, Req, required, 11, 16 resistance, 1-2 Resistant, 1, 10 resistant, 1-2 Resource, 3, 11 REV, 5-8 REVERSE, 3, 7, 13 Roto, 11 Round, 5, 14 rubber, 1 RUN, 5-8 RUNNINGs, 7
23 Index S Screw, 14, 16 screw, screws, 1, 14 sealed, 1-2 See, 11, 14 see, Selection, 1, 3 selection, 3 Selector, 5-6, 8-11, 14 selector, 3, 5-7 Separately, 4 separately, 8 Series, 1-2, 7-10 series, 1, 4 shallow, 8 Sheet, 11 Shield, 14 Ship, 15 Shown, 8 SHUT, 4 Shut, 2 Similar, 14 Single, 1, 4, 9-10, 12, 15 single, 11 SIZE, 12 Size, 16 size, 11 SIZEthe, 11 sketches, 11 SLOW, 5-7, 13 smaller, 2 Smushroom, 9 Sold, 4 spare, 1 Special, 1-2, 6, 11-12, 15 Specific, 1 Specification, 1, 11 Specifications, 1, 4, 15 specified, 11 Specify, 6, 11 specify, 11 spring, 13 Square, square, 10 Stainless, 9-10, 16 stainless, 1-2 STAMP, 11 Standard, 1-2, 7-8 standard, 6-8, START, 3, 5-10, 13 Station, 5-6, 8, 12, 15 station, 8, 11 Stations, 1-16 stations, 1, 3-4 STD, 12 Steel, 9-10, 16 steel, 1-2 Step, STOP, 3-10, 13 Stop, 8 stop, 3-4 such, 2 Suffix, supplied, 8 Support, 1-16 support, Surface, 1, 8, 16 surface, 8 Switch, 5-6, 8-10, 14 switch, 3, 5-8 Symbol, 5-6, 9-10 System, 11 T TA, 8 Tap, 15 TBG, 8 Tech, 1-16 Technical, 1, 3, 11, 15 terminal, 14 TGL, 8 TGR, 8 TGS, 8 than, 2 the, 3-4, 11 this, 3, 11 Three, 3, 5-10, 15 three, 1, 3, 8 To, 12 to, 3-4, 8, 10-12, 14 Top, 1, 11 top, 13 Total, 12 transformer, 8 TRC, 3, 11-12
24 Index TS, 11 twist, 3 Two, 3, 5-10, 13, 15 two, 1, 3, 7, 13 Type, 1-2, 4-10, type, 1, 3-4, 8, 10 TypeFlush, 5 types, 10 U UL, 1-2, 4-10 ultraviolet, 10 Unassembled, 7 unique, 4 Unit, 12 unit, 11 units, 1-2 UP, 3, 5-6, 8, 13 USE, 12 Use, 10 use, 11 used, 13 users, 2 Uses, 8 V Vac, 3, 9 variety, 4 VENTILATION, 4 Vertical, 3 vertical, 1 vibration, 1-2 VISTA, 11 Voltamperes, 15 Volts, 15 Volume, 1-16 V, 3 VVertical, 3 W wall, 1-2 What, 4 when, 13 where, 10 White, 3 white, 4 Wide, 16 will, 11 wiring, 1-2 With, 6-8 with, 1-2, 5, 7-11 Within, 11 Without, 7 Wt, 15 www, 1-16 Y Yellow, 3 yellow, 1-2 you, 11 your, 11 Z Zinc, 2 zinc, 1-2, 4 Zone, 1
Pushbuttons and Indicating Lights
10250T Pushbuttons.1 Toggle Switches E10 Product Description....................................... Product Selection......................................... Technical Data and Specifications.............................2
More informationPushbuttons and Indicating Lights
0250T Pushbuttons. Toggle Switches E0 Product Description....................................... Product Selection......................................... Technical Data and Specifications..............................2
More informationJanuary 2001 Vol. 2, Ref. No. [0880] 10250T/E34 Series, Assembled Devices Momentary Pushbutton Units
47 2in Cutler-Hammer Pushbuttons and Indicating Lights 30.5 mm Class I Division 2 Watertight/Oiltight Vol. 2, Ref. No. [0880] / Series, Assembled Devices Momentary Pushbutton Units Flush Button 706B Extended
More informationPushbuttons and Indicating Lights
Pushbuttons and Indicating Lights 0250T Pushbuttons. Toggle Switches E0 Product Description....................................... Product Selection......................................... V7-T-2 V7-T-4.2
More informationPushbuttons and Indicating Lights
10250T Pushbuttons M22 Modular Pushbuttons.1 Toggle Switches E10 Product Description.......................................... T-2 Product Selection............................................ T-4 Technical
More informationN2S and N2SC Series Control Stations
NEMA, 4X, 7BCD (Div. 2), 2 Applications: N2S and N2SC pushbutton stations, selector switches and pilot lights are suitable for use: In Class I, Groups B, C, D; Division 2 hazardous areas where flammable
More informationPush Button & Selector Switch Components. Operator Protective Boots EXPLOSIONPROOF AUXILIARY DEVICES EXPLOSIONPRROOF AUXILIARY DEVICES
Push Button & Selector Switch Components XMB XHDPL Operator locking caps and actuator devices can be adapted to existing explosion proof operators. Simple installation requires removal of top cap and threading
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationPENDANT PUSHBUTTON STATIONS
SBP2 PENDANT PUSH STATIONS SBP2 PENDANT PUSH STATIONS THE LIGHTWEIGHT PENDANT STATION FOR HEAVYWEIGHT APPLICATIONS COMPLETE PENDANT STATIONS 2, 4, 6, 8, 10, or 12 button configurations 1, 2, or 3 speed
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationDS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DS185 1G FS Box Switch Cover Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category
More information800 T A 1 A. f (cont'd) d (cont'd) f (cont'd) Momentary Contact Push Button Devices, Non-Illuminated. Rockwell Automation Publication 800-TD009A-EN-P
NEM Push Button Specifications 800T/H 30.5 mm Push Buttons Momentary Contact Push Button Devices, Non-Illuminated Flush Head Unit Cat. No. 800T-1 Extended Head Unit Cat. No. 800T-B6 Booted Unit Cat. No.
More information2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13
2-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A a b c d e a Protection Rating T Metal, Type 4/13 Blank C H31 H32 H33
More informationPush buttons and selectors
Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug
More informationTelephones. GB90 Series Options. Products. New. Jacks Inserts. Modules. Work Area Outlets. Telecom Room. Patch Cords. Video & Coax.
Outdoor Housings are constructed of die cast aluminum and electrostatically deposited enamel finish GB90 series of telephones are equipped with either a push latch or a push key lock All housings are equipped
More informationProduct Description. Selector Switches
-100 F SS Vol. 2, Ref. No. [0770] Contents Description Page Product Description......... -100 Features................... -100 Standards and Certifications............. -100 Technical Data..............
More informationCrane Control Class 9004
Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................
More informationPushbutton and selector switch series Quality touch!
Pushbutton and selector switch series Quality touch! For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 00-1-07 Fax: 71-7-70 Pushbuttons and selector switches Ømm Quality touch! mm
More informationEJB Junction Boxes Dimensions Pg. 132
6F EJB Junction Boxes Dimensions Pg. 132 Application: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch
More informationE30 Series, Operators & Indicating Lights
March 2008 E30 Series, Operators & Indicating Lights -103 Square Multifunction Operators and Indicating Lights (Continued) Table -145. Single Button Operator with Indicating Light/without Button or Order
More informationSensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52.
Retroreflectors Sensor Accessory AC Sensor Tester/Demonstrator Pilot Device E65 Control Unit.1 Retroreflectors and Retroreflective Tape Product............................................. 414 Application..........................................
More informationAllPro Hazardous/Corrosive Area Fluorescent
CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - 4X UL 844 - Class I Div. 2 - Groups A, B, C, & D UL 4X UL - Outdoor
More informationDUCT-O-WIRE. Enclosed Pendant Push Button Stations CAUTION
DUCT-O-WIRE Enclosed Pendant Push Button Stations Switches and Accessories Cables and Cable Assemblies has the most complete line of pendant stations in the industry. We offer a variety of pendants ranging
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationPush Buttons and Operator Interface New Product Catalog XAL Control Stations
Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104
More information22mm Non Illuminated Metal Operators
22mm 22mm Non Illuminated Metal Operators Altech Corp. can provide other push button and actuator options. If your requirement calls for a 22 mm operator which is not shown, please do not hesitate to call.
More informationContents. Volume 8 Sensing Solutions CA E February
Limit Switches.2 Product Description The E47 Compact Prewired Limit Switch by Eaton s electrical sector is designed to be a versatile, slim device for hard to fit applications where sealing integrity is
More informationSIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS
SIZE, AND POLYAMIDE PRE-DRILLED CONTROL STATIONS 0986 00 0986 0 0986 0 0986 8 Size, and pre-drilled control stations with component fixed on the base* Compact enclosure, polyamide body and cover x M0 clearance
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationControl Units Ex e in Stainless Steel LCS*.*
Features Assembly Stainless steel enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de and Ex tb Up to 4 operators per control unit, base-mounted contact blocks Wide choice of operators,
More informationPUSHBUTTONS. Easy Selection Guide CONTROL DEVICES. nhp-nz.com
PUSHBUTTONS Easy Selection Guide CONTROL DEVICES nhp-nz.com s Lens Legend Plates (optional) Contact Blocks & Coupling Plates (Plastic or Metal) Accessories & Enclosures page 3-4 page 5 page 6-7 page 8
More informationPower-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features
Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate and Cooling Fan Model: NB141207-40F Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power-Over-
More informationInductive Proximity Sensors E51 Limit Switch Style, Modular
September 2009 1 E51 Modular Limit Switch Style This Rugged Sensor Family Features Modular Components for Versatile Sensing Contents Overview...................... 1 Assembled Sensors............ 2 Sensor
More informationPower-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate. Model: NB Applications and Features
Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate Model: NB141207-400 Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet Indoor
More informationExplosionproof & Dust-Tight Push Buttons
AND DUST-TIGHT PUSH BUTTONS PUSH BUTTONS Explosionproof & Dust-Tight Push Buttons NEMA 3, 4, 7 & 9 All operators are die cast aluminum alloy. The barrels are all ¾ NPSM thread. Maximum installation thickness
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationCrane Control Contactors and Relays
October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver
More informationPower-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans
Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet
More informationPushbuttons and Indicating Lights. Protection Type IP66 NEMA 4X, 13
.5 Pushbuttons and Indicating Lights Product Description Eaton s M22 double pushbutton line is perfect for applications such as motor and pump starting, as well as anytime space is limited. In addition
More informationLimit Switches E47 Precision Switches
June 09 E7 Precision Switches PG.0C.0.T.E 1 E7 Precision The Cost-Effective Solution for Highly Accurate Switching Applications Contents Overview...................... 1 Model Selection, Basic Switches................
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch selector switch > 2 contact elements
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationXCE SERIES & XJF. XCE/XJF Enclosures West 150th Street, Cleveland, Ohio TEL FAX
EXPLOSIONPROOF EXPLOSIONPROOF INSTRUMENT ENCLOSURES HOUSING XCE: Explosionproof Control Enclosures XCEX: Flameproof Control Enclosures XCEQ: Explosionproof Quad-Lead Control Enclosures XJF: Explosionproof
More informationUNDERCARPET CABLING SYSTEM For Power and Communications
UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications
More informationMachine Safety. Products
January 23 Vol. 2, Ref. No. [1263] -1 Machine Safety Products Contents Description Page............................................. -2 Key Interlock Switches DIN Models.............................. -9
More informationVersaPro Non-Metallic Fluorescent
CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Class III CSA - Type 3 R Enclosed & Gasketed Features: Non-Metallic Fluorescent
More information22.5 Mm IEC. Product Selection. Emergency Stop Operators. Key Release Mushroom Operator. Non-Illuminated Twist-to-Release, Push-Pull
22.5 Mm IEC Product Selection Emergency Stop Operators Non-Illuminated Twist-to-Release, Push-Pull 60 mm Non-Illuminated Twist-to-Release 800FP-MT64 40 mm Non-Illuminated Push-Pull 800FP-MP44 Color Size
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More informationInternational, LLC. 22mm Push Buttons & Operator Interface - PB(M)22. Features
International, Features Available in die cast chrome plated and double insulated head Wide varity of operators available Double break, slow action, self-clean contacts Positive opening of normal close
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationPush Buttons. Discount Schedule JC33. Legend Plates OFF. Standard Legend Plates - Available with markings listed below at $3.60 list each.
Push Buttons 100T Legend Plates Standard Legend Plates - Available with markings listed below at $3.60 list each. Non-Standard Legend Plates - Can be provided with special markings at $15.60 list each.
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...
Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering
More information05/029. RMQ Titan Standard Legend Plates, Insert Plates Go to: List
RMQ Titan Standard Legend Plates, Insert Plates 05/029 Standard legend plates 30 x 50 mm, round, Type 0 I M22S-ST-X88 216485 0 I M22S-ST-X89 218147 I 0 II M22S-ST-X93 216486 STOP M22S-ST-GB0 216494 START
More informationPushbutton Switches, 16mm, Illuminated
Pushbutton Switches, 16mm, lluminated lluminated Pushbuttons are instrument-grade switches having snap-acting double break contacts, silver clad and gold plated to satisfy the requirements of logic level
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More information1.5. Pushbuttons and Indicating Lights. Contents Description Selector Switches Illuminated Switches... Selector Switches
.5 Pushbuttons and Indicating Lights Selector Switches Contents Description Selector Switches Non-Illuminated Switches................. Illuminated Switches.................... Key Operated..........................
More informationAutomation Products. Pilot devices The complete range
Automation Products Pilot devices The complete range Pilot devices Contents Presentation of the complete range 2 The whole range 4 Modular range, 22 mm General description 7 Pushbuttons, type MP, MPD 10
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationBrasch Washdown Unit Heaters
Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...
Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary
More information22mm Non Illuminated Metal Operators
22mm 22mm Non Illuminated Metal Operators Altech Corp. can provide other push button and actuator options. If your requirement calls for a 22 mm operator which is not shown, please do not hesitate to call.
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationCAMDEN MOUNTING BOXES
DOOR ACTIVATION DEVICES ENCLOSURES AND MOUNTING BOXES CAMDEN MOUNTING BOXES FEATURES THE INDUSTRY'S LARGEST ASSORTMENT OF MOUNTING BOXES, ESCUTCHEONS, TRIM PLATES AND SLEEVES. FEATURES SOLUTIONS FOR SURFACE
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationLinear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2
> For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationExplosionproof Meter Housings
METER HOUSINGS Explosionproof Drilled and tapped to specification, attach layout sheet. Dimensions are internal. XJDGCH N4 XJDFGCH N4 4 1/8 x 4 1/8 X 3 XJMCGCH N4 6 3/4 x 6 3/4 x 3 XJTGCH N4 XJTFGCH N4
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...
Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand
More informationOiltight Switches & Pilot Devices
ø22mm - TW Series Accessories TW Series Accessories Appearance Description/Usage Part Number Lamp Removal Tool Rubber tool used to install or remove LED s and incandescent lamps OR-55 Contact Block Remover
More informationMODEL SW6000 & SM6100 CENELEC INSTRUCTIONS
MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805
More informationInverter Selection Guide
Inverter Selection Guide KB Electronics, Inc. Chassis / IP20 models include Motor Filters to eliminate winding and bearing failures. Hybrid Drives are digital drives with an analog interface. Digital models
More informationPhotoelectric Sensors 20 Series
PG.05E.22.T.E Extremely Rugged Construction, Long Sensing Ranges and High Current Switching Contents Overview........................ Model Selection, Sensors......... 2 Model Selection, Output Devices..................
More information120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS
120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB181608-10FS Applications and Features Features: Molded Fiberglass Reinforced Polyester
More informationLetter Color. Background Color. Field Color. Split Field Color. Standard Plastic, NEMA 1 Only. White Black Black E22NSP77 E22NSP90 E22NSP11 E22NSP12
March 2008 E22 and EM22 Series, Legend Plates with Markings -79 Options Legend Plates Engraved Legend Plates with Markings 1/8" High Character Size legend plates installed with aluminum legend plates have
More informationCOMPACT30 Warning Tower Lights - General Description...J17 Complete Assemblies...J19 Accessories...J20 Technical Information...J21
SIGNAL50 - General...2 Light Modules...4 Bulbs...5 Sound Modules...6 Mounting Bases...7 Accessories...9 Complete Assemblies...10 Technical Information...12 COMPACT30 - General...17 Complete Assemblies...19
More information80 Series Push Button Pendant Features
80 Series Push utton Pendant Features he Conductix-Wampfler 80 Series Push utton Pendants are available with a wide variety of switch types, options, and accessories for easy customization. You can get
More informationSECTION ELECTRICAL CONTROL DEVICES
ELECTRICAL CONTROL DEVICES PART 1 GENERAL 01 02 03 04 05 SCOPE The Contractor shall furnish and install, where indicated on the drawings, equipment with electrical control devices installed as specified
More information800F 22 mm Push Buttons. The Time-saving Product Line Quick Selection, Superior Design, Fast Installation
800F 22 mm Push Buttons The Time-saving Product Line Quick Selection, Superior Design, Fast Installation Modular Flexibility Non-Illuminated Devices Max. 6 Contact Blocks Illuminated Devices 2 Superior
More informationMetering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs
.3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton
More informationSurface-Mounting Product Ranges
Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd
More informationPanel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet
Panel Enclosures Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Construction Enclosure and door are fabricated from code gauge steel (see page 153) All continuous
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationLarge DIspLay process Meters
Large DIspLay process Meters Model pd650 NeMa 4X 2.3" High LeD Model pd655 NeMa 4X 1.0" High LeD Model pd656 exp-proof 4X 0.8" High LeD 4-20 ma, 1-5 V, 0-5 V, 0-10 V inputs 4½ digit + extra zero display
More informationInView Marquee Message Display
Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.
More informationContents. Volume 8 Sensing Solutions CA E April
Inductive Proximity Sensors.9 Product Description These unique Inductive Proximity Sensors by Eaton s electrical sector are designed to be used in extremely small spaces. A wide variety of models are available
More information120 VAC 14x12x7 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fan and Solid State Fan Controller Model: NB FS
120 VAC 14x12x7 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fan and Solid State Fan Controller Model: NB141207-10FS Applications and Features Features: Molded Fiberglass Reinforced Polyester
More informationCamden - Key Switches
- Key Switches CM1120 - Flush Mount Key Switch 1 SPDT Momentary CM1130 - Flush Mount Key Switch 1 SPDT Maintained CM1120 CM1120 CM1120 CM2020 - Narrow Style Key Switch 1 SPDT Momentary CM2030 - Narrow
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997
More informationContender LED Luminaires Enclosed and Gasketed Fixtures
Class I, Division, Groups A,B,C,D Class I, Zone, Group IIC Class II, Division, Groups E,F,G Zone and, Group IIIC Class II, Division, Groups F,G Type R, 4, 4X Applications Enclosed and gasketed fixtures
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationLUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, ring nut fixing LUMOTAST 25 keylock switch 1-30 LUMOTAST 25 keylock switch 1-31
TAST General data TAST pushbutton range Illuminable pushbuttons and signal lamps. Please order lamps/leds separately. Mounting hole diameter: 6.2 mm 42 V/00 ma max. Water-jet proof IP65 Low profile Lamp
More informationELECTRICAL CONTROL SYSTEM COMPONENTS
Module - 2 ELECTRICAL CONTROL SYSTEM COMPONENTS Lecture - 1 MECHANICAL SWITCHES Shameer A Koya EEET 221 : Electrical Control Systems. Module 2 - Objectives State the functions of control system components
More informationEnclosures for Remote I/O System I.S. 1
STAINLESS STEEL (V2A) STAINLESS STEEL (V4A) POLYESTER RESIN IP66 For Installation in II 2 G EEx e II Increased safety protection Certified according to 94/9EG (ATEX) For Installation in Zone 2 Declaration
More information1.4. Pushbuttons and Indicating Lights. Product Overview
Contents Product Overview Product Description The RMQ-6 pushbutton line offers a wide array of functional and attractively designed illuminated and non-illuminated pushbuttons, selector switches, emergency
More information