1 Part E, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. All All All All Vista Standard (V) Vista Pattern (PC)
2 E 1-0
3 E 1-1 Section E 1 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 1. Introduction The input/output (I/O) board for Series 3000V hot melt units allows you to connect devices to the unit to remotely monitor and control key unit features. The I/O board is available in two versions: standard and enhanced. The standard I/O board inputs allow you to remotely turn the standby feature on remotely turn the heaters on have the unit automatically enter the standby mode if guns are not fired for a specified period of time The standard I/O board outputs allow you to remotely monitor power on/off status pump on/off status standby on/off status warning conditions In addition to providing the same inputs and outputs as the standard I/O board, the enhanced I/O board has additional inputs that allow you to remotely disable hoses and guns.
4 E Introduction (contd.) See Figure E 1-1. The I/O board has two terminal blocks where you connect the I/O wiring. On the standard I/O board, the terminal blocks are labeled TB10 and TB20. On the enhanced I/O board, they are labeled X1 and X A 4 5 Fig. E 1-1 Standard I/O Board (A) and Enhanced I/O Board (B) 1. TB10 terminal block 4. X2 terminal block 2. XP5 card edge connector 5. X1 terminal block 3. TB20 terminal block B See Figure E 1-2. The I/O board plugs into the XP5 card edge connector, which is located inside the electrical enclosure behind the operator panel portion of the control-end frame Fig. E 1-2 XP5 Card Edge Connector 1. Control-end frame 2. Flange 3. XP5 card edge connector
5 E Input/Output Connections If you purchased the I/O board option for your unit, the I/O board is already installed. You will need only to install ferrites and connect the I/O wiring. A ferrite is a device used to reduce electrical noise. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Turn off the unit; then disconnect and lock out electrical power to the unit. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure in the Control section. 3. If you have not already done so, carefully remove a plug from one of the smaller knockout holes on either the back side or the bottom of the unit (whichever is most convenient for your operation) and install a strain relief to support and protect the I/O wiring. Avoid contact with any printed circuit boards. WARNING: Risk of equipment damage, personal injury, or death. For a proper and safe installation, make sure you meet the requirements in the following step. 4. See Figure E 1-3. Route the I/O wiring through the strain relief and the two ferrites from the ship-with kit to the I/O board terminal blocks. Make sure your installation meets these requirements: Use mm 2 (22 24 AWG) stranded wire that is suitable for National Electrical Code (NEC) Class 1 remote control and signaling circuits. Output contacts are rated for 250 VAC, 2 A maximum. Use the proper length of wire and route the wires so they do not touch any of the printed circuit boards. Make sure the wires reach the I/O board terminal blocks when the electrical enclosure is opened. Position the ferrites as close to the rear panel as possible.
6 E Input/Output Connections (contd.) A Fig. E 1-3 Connecting Input/Outputs to the I/O board
7 E See Figure E 1-4. Connect the I/O wires to the appropriate terminal blocks. Refer to Table E 1-1 (standard I/O boards) or Table E 1-2 (enhanced I/O boards) for terminal block connections. Table E 1-1 Standard I/O Board Connections TB20 Outputs TB10 Inputs (See Note A) Function Controlled Remotely Terminals Indication Shown Remotely Terminals Turn standby feature on (See Note B) 1, 2 Turn heaters on/remote pump enable (See Note B) Enter standby if guns are not fired within a specified period of time (See Note C) 3, 4 5, 6 Power on/off status (normally closed when system is powered) Pump on/off status (normally closed when pump is on) Standby on/off status (normally closed when system is in standby) Warning condition (normally closed when no warning condition exists) NOTE A: Output contacts are rated for 250 VAC, 2 A maximum. B: This input is activated by supplying between VDC across the designated terminals of the I/O board. If the voltage is removed, the input is deactivated. C: This input is activated by programming Feature 30, Auto Standby Timeout. A gun is usually signaled to fire by a timer or programmable logic controller (PLC). If a time value other than zero (0) is entered in Feature 30 (Auto Standby Timeout), the unit will automatically enter the standby mode if a gun is not fired during the specified time period. Refer to Timeout Features in this section. 1, 2 3, 4 5, 6 7, 8 TURN STANDBY ON TURN HEATERS ON ENTER STANDBY IF GUNS NOT FIRED 1, 2 3, 4 5, 6 TB STANDBY ON/OFF STATUS 5, 6 WARNING CONDITION 7, 8 TB20 1, 2 3, 4 POWER ON/OFF STATUS PUMP ON/OFF STATUS A Fig. E 1-4 Standard I/O Board Connections
8 E Input/Output Connections (contd.) Table E 1-2 Enhanced I/O Board Connections X1 Inputs X2 Outputs (See Note A) Function Controlled Remotely Terminals Indication Shown Remotely Terminals Turn standby feature on (See Note B) 1, 2 Turn heaters on (See Note B) 7, 8 Enter standby if guns are not fired within a specified period of time (See Note C) 13, 14 Disable hose and gun one (See Note B) 9, 10 Power on/off status (normally closed when system is powered) Pump on/off status (normally closed when pump is on) Standby on/off status (normally closed when system is in standby) Warning condition (normally closed when no warning condition exists) Disable hose and gun two (See Note B) 3, 4 Disable hose and gun three (See Note B) 15, 16 Disable hose and gun four (See Note B) 11, 12 Disable hose and gun five (See Note B) 5, 6 Disable hose and gun six (See Note B) 17, 18 NOTE A: Output contacts are rated for 250 VAC, 2 A maximum. B: This input is activated by supplying between VDC across the designated terminals of the I/O board. If the voltage is removed, the input is deactivated. If a zone is enabled through the I/O board, the READY light will not turn on until that zone is within 5 F (-15 C) of its setpoint temperature. C: This feature is activated by programming Feature 30, Auto Standby Timeout. A gun is usually signaled to fire by a timer or programmable logic controller (PLC). If a time value other than zero (0) is entered in Feature 30 (Auto Standby Timeout), the unit will automatically enter the standby mode if a gun is not fired during the specified time period. Refer to Timeout Features in this section. 1, 2 3, 4 5, 6 7, 8 7, 8 TURN HEATERS ON ENTER STANDBY IF 13, 14 GUNS NOT FIRED DISABLE HOSE/GUN 15, 16 THREE 17, 18 DISABLE HOSE/GUN SIX 9, 10 DISABLE HOSE/GUN ONE X1 U1 U2 U3 U4 U10 1, 2 TURN STANDBY ON 3, 4 DISABLE HOSE/GUN TWO 5, 6 DISABLE HOSE/GUN FIVE U9 U8 U7 U6 U5 DISABLE HOSE/GUN FOUR 11, 12 K2 X2 K3 STANDBY ON/OFF STATUS5, 6 K4 1, 2 POWER ON/OFF STATUS WARNING CONDITION7, 8 K5 3, 4 PUMP ON/OFF STATUS A Fig. E 1-5 Enhanced I/O Board Connections
9 E Close and secure the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure in the Control section. 7. Restore power to the unit and resume normal operation. 3. Additional Features The I/O board adds the following additional features that can be programmed using the SYSTEM SETTINGS controls: Auto Standby Timeout In Standby Timeout Remote Heaters On/Remote Pump Enable Rempote Pattern Select (Pattern control units only) Each feature is factory-set at zero (0), which means the feature is disabled. To program these features, refer to Programming SYSTEM SETTINGS Controls in the Installation section. Refer to Table E 1-3 for a description of how each feature works and a range of possible settings. Table E 1-3 SYSTEM SETTINGS Timeout Features Feature No. Feature Description Default Setting 30 Auto Standby Timeout 31 In Standby Timeout 34 Remote Heaters On/Remote Pump Enable 38 Lose Ready On/Remote Enable 51 Remote Pattern Select (Pattern control units only) Allows you to program the unit to automatically enter the standby mode and maintain heated zones at standby temperature setpoints if a gun is not fired during the specified period of time. The unit will remain in standby mode indefinitely unless a gun is fired or unless a value other than zero (0) is entered in Feature 31, In Standby Timeout. Allows you to program the unit to automatically exit the standby mode and enter the sleep mode (turn the heaters off) if a gun is not fired during the specified period of time. Allows you to remotely turn heaters on or to enable/disable the pump. This feature is only available on the enhanced I/O board. Allows the user to decide whether or not the control system should lose ready status when a cold zone is enabled thorugh the enhanced I/O board. Allows a pattern to be selected through the I/O board. If this feature is set to 1 or 2, patterns can be selected via inputs on the I/O board. Refer to Table E 1-4 for the various settings. This feature is only available on the enhanced I/O board. 0 (setting is off) 0 (setting is off) 0 (Remote Heaters On) 0 (setting is off) 0 (setting is off) Optional Settings (minutes) (minutes) 0 (Remote Heaters On) 1 (Remote Pump Enable) 0 (off) 1 (on) 1 or 2
10 E Additional Features (contd.) Table E 1-4 Remote Pattern Select Settings Setting 1 Setting 2 Hose/Gun 5 Hose/Gun 6 Pattern Number Remote Gun Hose/Gun 5 Hose/Gun 6 Pattern Number Off Off Pattern Control Disabled Off Off Off Pattern Control Disabled Off On 1 Off Off On 1 On Off 2 Off On Off 2 On On 3 Off On On 3 On Off Off 4 On Off On 5 On On Off 6 On On On 7
11 E I/O Board Replacement Use this procedure to replace a defective I/O board with a new I/O board. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Turn off the unit; then disconnect and lock out electrical power to the unit, including I/O lines. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure in the Control section. 3. Remove the screw that holds the board to its bracket inside the electrical enclosure. NOTE: A new bracket is included in the service kit. If desired, you can replace the existing bracket with this new bracket. 4. Label or note existing connections for later reference, then disconnect wires from the board and pull the board out of the XP5 card edge connector. 5. Remove the new board from its static-safe container, making sure to handle the board by its edges without touching pins, wires, or circuitry. 6. Carefully install the new board in the XP5 card edge connector and attach the board to the bracket with the screw provided in the service kit. Tighten the screw to N m (18 20 in.-lb). 7. Reconnect wires to the new I/O board. Refer to Table E 1-1 (standard I/O boards) or Table E 1-2 (enhanced I/O boards) in Input/Output Connections for terminal connections. 8. Close and secure the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure in the Control section. 9. Restore power to the unit and resume normal operation.
12 E Troubleshooting For wiring information, refer to the Wiring Diagrams section. Problem Possible Cause Corrective Action 1. Inputs not being recognized Loose connection Input voltage not sufficient Defective I/O board Check the tightness of connections at the I/O board and at the remote devices. Tighten any loose connections. Make sure the voltage across the appropriate terminals on X1 or TB10 is VDC. Replace the I/O board. Refer to I/O Board Replacement. 2. Outputs not working Loose connection Check the tightness of the connections at the I/O board and at the remote devices. Tighten any loose connections. Defective I/O board Replace the I/O board. Refer to I/O Board Replacement.
13 E Parts To order parts, contact the Nordson Customer Service Center or your local Nordson representative. Use the following parts list to describe and locate parts correctly. See Figure E 1-6. Item Part Description Quantity Note Service kit, standard I/O board, Vista Service kit, enhanced I/O board, Vista Bracket, I/O board Circuit board, standard I/O 1 A Circuit board, enhanced I/O 1 B Screw, hex head, M4 x 12 mm Screw, pan head, M3 x 10 mm Washer, lock, split, M Washer, flat, narrow, M3 2 NS Inductor, bead, 1.41 in. diameter (ferrite) 2 NOTE A: Included in service kit B: Included in service kit NS: Not Shown Fig. E 1-6 I/O Board Service Kit Parts
14 E 1-12
AutoScan to MultiScan Replacement Kit
Instruction Sheet P/N AutoScan to MultiScan Replacement Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other
More informationControl. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)
Part B, Section 2 Model This section covers the following unit configurations. 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G) Manifold 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Temperature
More informationInk-Dot Series II Driver
Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with
More informationReplacing a Precision Controller Circuit Board
Instruction heet Replacing a Precision Controller Circuit Board WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all
More informationSection 11. Electrical System. 42--CF200--MA--09 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved
ection 11 Electrical ystem 11-0 Electrical ystem Table of Contents i Table of Contents ection 11 Electrical ystem 1. Introduction... 11-1 Electrical Operation... 11-2 Heating Zones... 11-2 2. Electrical
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationo-o Nordson Manual (S)46.10 Series 2000 Hose/Gun Temperature Controller (S)46.10=Issued Corporation 1987 Publication No.
o-o Nordson Manual (S)46.10 Series 2000 Hose/Gun Temperature Controller (S)46.10=Issued 5/87@Nordson Corporation 1987 o-00 Data and specifications included within this mlanual are accurate at the time
More informationInstallation Guide SMT 2200/3000 VA Input/Output Hardwire Kit
Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation
More informationSure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B
Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card Customer Product Manual Issued 4/02 For parts and technical support, call the Industrial Coating Systems Customer Support Center
More informationTorque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24
Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety
More informationC-POWER AC AUTOMATIC CONTROL
Issue 1 Print 1 C-POWER AC AUTOMATIC CONTROL INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model: 93 ACMC100I A Charles Industries, Ltd. All rights reserved. Printed in the United States of America. Issue
More informationIC693 PLC IC693ACC350, IC693ACC340/341
March 29, 2001 IC693 PLC IC693ACC350, IC693ACC340/341 Redundant Power Supply System he IC693 Redundant Power Supply System consists of a Baseplate and an Adapter, described below. Redundant Power Supply
More informationPS/IO Circuit Board Retrofit
S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....
More informationInstallation, Start-up and Operating Instructions
Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol
More informationSeries 3700 Screw Terminal Assemblies Installation Instructions
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling
More informationGCI-5K INSTALLATION AND OPERATOR S MANUAL
GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter
More informationCOMFORT CONTROL CENTER SERVICE INSTRUCTIONS
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center
More informationAnalog Monitor Installation Manual
Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationSeries 3000 Low Level Indicator
instruction 46-92 Page 1 (For Series 3400,350O and 3700 applicators only) DESCRIPTION The Low Level Indicator will provide a contact closure to indicate when the level of adhesive in the tank falls to
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationLevelOne KVM User Manual. 17 Modularized KVM Console V
LevelOne KVM-0217 17 Modularized KVM Console User Manual V1.0.0-0708 SAFETY INSTRUCTIONS 1. Please read these safety instructions carefully. 2. Please keep this User Manual for later reference. 3. Please
More informationLevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version
LevelOne KVM-0115/KVM-0117 15 / 17-inch LCD KVM Rack Console User Manual Version 1.0-1305 1 SAFETY INSTRUCTIONS 1. Please read these safety instructions carefully. 2. Please keep this User Manual for later
More informationSidewinder Pumps Inc. AC C1D2 Timer/Controller
Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------
More informationInstallation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit
Installation Note Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit 85105-60047 Part Number 85105-90023 Printed in USA August 2002 Notice. The information contained
More informationINSTALLATION INSTRUCTIONS
TT-40 9/0 INSTALLATION INSTRUCTIONS Original Issue Date: 9/0 Model: Automatic Transfer Switches Equipped with the Programmable Controller Market: ATS Subject: External Battery Supply Module Kit GM69-KP
More informationProcedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer
Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer Difficulty Level: Medium Estimated time to execute: 1 Hour Revision History Issue Date Reason 001 5/31/2016 Initial
More informationSidewinder Pumps Inc. AC Timer/Controller
Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.
More informationMC-3 Master Control Unit
MC-3 Master Control Unit Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local Nordson
More informationFUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide
FUSION RX1600RAID Rackmount 16-Drive SATA Storage System with Internal SAS Expanders Drive Enclosure User s Guide Fusion RX1600RAID Enclosure Specs and Features SAS Cable Connection Indicators Mute Button
More informationFUSION 400. User s Guide. 4-Bay Serial ATA Hot-Swap Drive Enclosure. For Windows
FUSION 400 4-Bay Serial ATA Hot-Swap Drive Enclosure User s Guide For Windows Fusion 400 Specifications and Features Drive Tray (Slot 1) Drive Tray (Slot 2) Drive Tray (Slot 3) Drive Tray (Slot 4) Specifications
More informationB&W RearView Camera Installation & Operation
B&W RearView Camera Installation & Operation CA52 (Camera) FOR MORE INFORMATION WWW.STRATEGICVISTA.COM BEFORE OPERATING THIS SYSTEM, PLEASE READ THIS MANUAL THOROUGHLY AND RETAIN IT FOR FUTURE REFERENCE
More informationMODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT
MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationAnalog Input Installation Manual
Analog Input Installation Manual August 2011 Part Number: 144-23917 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems
More information24/48/120 VAC Interface Card Instruction Manual
24/48/120 VAC Interface Card Instruction Manual Distributed by Ergonomic Partners Sales@ErgonomicPartners.com www.ergonomicpartners.com Tel: (314) 884-8884 April 2012 Part Number: -R2 Copyright 2012 Magnetek
More informationXDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116
XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116 XDBKITS5 Option Kit Installation Manual vacon 3 Installing the Bus / DB Terminal Option Kit Introduction The XDBKITS5 option kit is
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationSystem Storage EXP3000 Rack Installation Instructions
System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationAltivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216
Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216
More informationInstallation and Wiring
Wiring 2 2 Plan for Safety Safety Techniques WARNING: Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationInstruction Sheet WPC 2000 Option 1
Instruction Sheet WPC 2000 Option 1 This document shows you how to install, wire, program, monitor, and troubleshoot WPC 2000 Option 1. Option 1 is compatible with WPC 2000 systems running WPC 2000 version
More informationand Network Interface Modules Installation Instructions
4010-9817 and 4010-9821 Network Interface Modules Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the
More informationM5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions
M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions Part No. 530-003244-01 Revision 1 27 July 2000 This document describes how to remove and replace the AC and DC power supplies,
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationFOR SERVICE TECHNICIAN S USE ONLY
Tech Sheet Do not discard DANGER WARNING Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before
More informationSoftware Installation Guide
KGASD0301APM APM FOR WINDOWS Software Installation Guide NOTE: Read the entire Software Installation Guide before using the APM for Windows software. SAFETY CONSIDERATIONS Installing and servicing heating
More informationFUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide
FUSION RX1600RAID Rackmount 16-Drive SATA Storage System with Internal SAS Expanders Drive Enclosure User s Guide Fusion RX1600RAID Enclosure Specs and Features SAS Cable Connection Indicators Mute Button
More informationUser's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
More informationHardware Replacement Guide
Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628
More informationSmart Battery Box Owner s Manual & Safety Instructions
Smart Battery Box Owner s Manual & Safety Instructions PLEASE READ THIS MANUAL BEFORE USE (866)721-0002 www.newportvessels.com support@newportvessels.com Dear Valued Customer, Thank you for purchasing
More informationH Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION
H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationInView Marquee Message Display
Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.
More informationhp uninterruptible power system r12000 xr models installation instructions
hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer
More informationUser Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch
User Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch LKS-CD19SR 19 LCD Single Rail Console Drawer with Modular KVM Switch Rev 2.0 Packing List ServerLink LKS-CD17SR / CD19SR
More informationMX1 Reversible AC Motor Controller. Supplementary Wiring Examples
MX1 Reversible AC Motor Controller Supplementary Wiring Examples DANGER Electrocution Hazard! Ensure all power is disconnected before servicing or wiring. Install all electrical equipment and wiring in
More informationRack Mount Power Supplies
Rack Mount Power Supplies Installation Guide Models Include: VertiLine33D - 12VDC @ 8A - Sixteen (16) PTC protected outputs VertiLine33TD - 12VDC @ 16A - Sixteen (16) PTC protected outputs VertiLine63D
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide
More informationMFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company
MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System User s Manual D-M-E Company D-M-E Company MFA-0801 & MFA-1201 Page 1 Copyright D-M-E Company 1995. All rights reserved. D-M-E
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationCoolwave 2 Control Board Upgrade Kit
Instruction Sheet P/N 1612622-01 Coolwave 2 Control Board Upgrade Kit NOTE: Retain the box used for shipping the control board and contactor to comply with the conditions of warranty. WARNING: Allow only
More informationInstruction Sheet Board Style Low Water Cutoff
Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationElecraft K3 KPA3 Power Connector Replacement Revision B, June 30, 2017 Copyright 2017, Elecraft, Inc. All Rights Reserved
Introduction Elecraft K3 KPA3 Power Connector Replacement Revision B, June 30, 2017 Copyright 2017, Elecraft, Inc. All Rights Reserved The connectors furnishing high current to the KPA3 module have failed
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationWOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112
SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL Models: SLC2102-SLC2112 SLC2102X-SLC2112X SLC2152-SLC2162 SLC2170-xx Relay
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationHigh Efficiency LED Driver DCCP-DPR Series USER MANUAL. This manual offers important information and suggestions with
EPSOLAR High Efficiency LED Driver DCCP-DPR Series USER MANUAL Thank you very much for selecting our DCCP-DPR LED Driver product! This manual offers important information and suggestions with respect to
More informationMBE Mounts and Adapters
MBE Mounts and Adapters MBE Series en Installation Guide MBE Mounts and Adapters Table of Contents en 3 Table of Contents 1 Important safety instructions 4 2 MBE Series Mounts and Adapters 6 2.1 Unpacking
More informationModel 2380 Rack-Mount Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount
More informationPower Supply (48Vdc, 2.5A)
Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationHUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide
G A I - T R O N I C S C O R P O R A T I O N A H U B B E L L C O M P A N Y HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide Important Safety Instructions Read, follow, and retain
More informationEcoFlex LED Neon Manual
Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationABM International, Inc. Lightning Stitch Checklist 9/13/2013
ABM International, Inc. Lightning Stitch Checklist 9/13/2013 1) Piggy backed board assembly (1) Piggy back board assembly tested? Yes No 24v passed XB passed XA passed YB passed YA passed SAFE passed S/S
More informationINSTRUCTION BULLETIN
INSTRUCTION BULLETIN No. 9008755 Machine: T16 Published: 03-2011 Rev. 00 NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts List in the appropriate place in the machine
More information2260B-RMK-Series Rack Mount Kit
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Assembly and Mounting Instructions Introduction The 2260B-RMK-Series Rack Mount Kit is suited for
More informationD Issue D Original. Instruction Manual. Micro Tool Interface
Instruction Manual D373-60-880 Issue D Original Micro Tool Interface Description SPI Micro-TIM MCM Micro-TIM TEL Micro-TIM SEMI E73 Micro-TIM LAM Alliance Micro-TIM Novellus C3 Micro-TIM Hitachi Micro-TIM
More informationFOR SERVICE TECHNICIAN S USE ONLY
Tech Sheet Do not discard DANGER WARNING Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before
More informationUser Manual. Solar Inverter for Water Pump
User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationIntel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide
Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationGV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000
GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000 Instruction Manual D2-3390-2 The information in this manual is subject to change without notice. Throughout this manual, the
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationUser Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size
User Manual 1U LCD Keyboard Drawer KwikDraw - A Series - With KVM options - 15", 17, 19 screen size 1.1 Important Safeguards Please read all of these instructions carefully before you use the device. Save
More information