EonStor DS. EonStor DS. Product Quick Reference Guide.

Size: px
Start display at page:

Download "EonStor DS. EonStor DS. Product Quick Reference Guide."

Transcription

1 EonStor DS EonStor DS Product Quick Reference Guide

2 EonStor DS Data Services EonStor DS Data Services THIN PROVISIONING Volume Copy/Mirror Snapshot REMOTE REPLICATION LOCAL REPLICATION EonStor DS is designed to support missioncritical applications of small and medium businesses (SMB), featuring redundant, hotswappable hardware components, CacheSafe technology and full RAID protection to deliver high faulttolerant capability. To protect data from even more critical threats, EonStor DS also features local and remote replication capabilities. By configuring the scheduler in SANWatch, users can automate replication tasks. In the event of human errors or data volume failures, differential and full copies of critical data sets can be leveraged to quickly recover data and restart service. In addition, thin provisioning enables users to optimize capacity utilization and minimize investments in large and underutilized data volumes. LOCAL REPLICATION SNAPSHOT Copyonwrite technology to create pointintime differential copies without disrupting online applications Restore deleted files or roll data volume back in seconds based on spacesaving recovery points VOLUME COPY/MIRROR Create independent pointintime and mirrored full data copies without downtime Allow production data to be immediately shared by secondary applications, such as testing, data mining and tape backup Restart service in minutes with minimized data loss when the source data volume fatally fails REMOTE REPLICATION Deploy full data copies across storage systems at different sites, either in synchronous or asynchronous mode Leverage diskbased remote copies to quickly restart services in the event of source data failures THIN PROVISIONING Allocate capacity dynamically when data writes happen to minimize expenses wasted on large and underutilized data volumes S P EC I F I C AT I O N S LOCAL REPLICATION¹ Standard¹ Advanced 3 Snapshot Maximum Number of Snapshot Images for a Source Volume Maximum Number of Snapshot Images in a System Volume Copy / Mirror 1,024 / 128 ² 4,096 Maximum Number of Source Volumes in a System Maximum Number of Replication Pairs for a Source Volume 4 8 Maximum Number of Replication Pairs in a System REMOTE REPLICATION 4 Maximum Number of Source Volumes in a System 16 Maximum Number of Replication Pairs for a Source Volume 4 Maximum Number of Replication Pairs in a System 64 THIN PROVISIONING 4 1. Standard functions are default available snapshot images on EonStor DS G7 models; all other models support 1,024 snapshot images. 3. Advanced functions are available with optional license. 4. Available with optional license; not available on EonStor DS G7 models.

3 Table of Contents EonStor DS Data Services 2 System Overview Connection & Shipping Product Introduction Connection Topology 32 High Capacity Guide Fibre Head 3 Fibre to Fibre Head Shipping Reference & Rackmount Kits 43 Shipping Reference 45 Rackmount Kits Fibre Host 4 Fibre to Fibre RAID System 5 Fibre to SAS RAID System SAS Host 14 SAS to SAS RAID System Software & Service SANWatch Overview Warranty & Quality Alliance Partner iscsi Host 18 iscsi to SAS RAID System Expansion Enclosure 21 Expansion Enclosure 2.5" Drive Fibre Host 25 Fibre to 2.5 SAS RAID System 2.5" Drive SAS Host 26 SAS to 2.5 SAS RAID System 2.5" Drive iscsi Host 28 iscsi to 2.5" SAS RAID System 2.5" Drive Expansion Enclosure " SAS Expansion Enclosure 2012 by Infortrend Technology, Inc. All rights reserved. Any information provided herein is without warranties of any kind and is subject to change by Infortrend without prior notice. * Infortrend offers a 3year limited warranty on systems. * Infortrend and the Infortrend logo are registered trademarks of Infortrend Technology, Inc. * EonStor, ESVA and SANWatch are registered trademarks of Infortrend Technology, Inc. * All other names, brands, products, or services are trademarks or registered trademarks of their respective owners. *

4 System Overview The EonStor DS family offers a wide range of models featuring diverse host and driveside connectivity types and form factors. Host connectivity includes Fibre Channel (4Gb/s and 8Gb/s), iscsi (1GbE and 10GbE), and SAS (3Gb/s and 6Gb/s). Supported drive types on EonStor DS models include Fibre Channel, SAS (3Gb/s and 6Gb/s) and nearline SAS. Form factors range from 1U to 4U, including models accommodating 3.5inch drives and models accommodating 2.5inch drives. 1U 2U 3U 4U iscsi Host iscsi I 6G SAS iscsi I 3G SAS ESDS B12ER21404 ESDS B12EG21404 ESDS S12ER21404 ESDS S12EG21404 ESDS B24ER21426 ESDS B24EG21426 ESDS S12EG11402 ESDS S16ER2240 ESDS S16EG2240 ESDS S16ER21426 ESDS S16EG21426 ESDS S16ER11404 ESDS S16EG11404 ESDS S24EG21426 SAS Host 6G SAS I 6G SAS ESDS S04SG2240 ESDS B12SR2240 ESDS B12SG2240 ESDS B12SJ2000R ESDS B12SJ2000G ESDS S12SR22404 ESDS S12SG22404 ESDS B24SR22424 ESDS B24SG22424 ESDS S12SR2240 ESDS S12SG2240 ESDS B24SR2240 ESDS B24SG2240 ESDS B24SJ2000R ESDS B24SJ2000S ESDS S12SJ2000R ESDS S12SJ2000G ESDS S12SJ2000RN ESDS S12SJ2000SN ESDS S16SR22404 ESDS S16SG22404 ESDS S16SR22424 ESDS S16SG22424 ESDS S16SR2240 ESDS S16SG2240 ESDS S16SJ2000R ESDS S16SJ2000S ESDS S24SG22404 ESDS S24SG2240 ESDS S48SJ2000R ESDS S48SJ2000G 3G SAS I 3G SAS ESDS B12SJ1000R ESDS B12SJ1000S ESDS S12SJ1002R ESDS S12SJ1000G ESDS S16SJ1000R ESDS S16SJ1000S 4G FC I 3G SAS ESDS S12FR1440 ESDS S12FG1440 ESDS S16FR1440 ESDS S16FG1440 ESDS S24FR1440 ESDS S24FG1440 Fibre Host 8G FC I 6G SAS ESDS B12FR28404 ESDS B12FG28404 ESDS B24FR28426 ESDS B24FG28426 ESDS B24FR28404 ESDS B24FG28404 ESDS S12FR28404 ESDS S12FG28404 ESDS S12FR2840N ESDS S12FS2840N ESDS S12FR2850 ESDS S12FS2850 ESDS S16FR28426 ESDS S16FG28426 ESDS S16FR28404 ESDS S16FG28404 ESDS S16FR2850 ESDS S16FS2850 ESDS S48FR28426 ESDS S48FG28426 ESDS S24FR28404 ESDS S24FG28404 ESDS S24FR2850 ESDS S24FG2850 8G FC I 3G SAS ESDS S12FR18404 ESDS S12FG18424 ESDS S16FR18404 ESDS S16FG18404 ESDS S24FR18404 ESDS S24FG18404 FC I FC ESDS FFR40316 ESDS FFS40316 ESDS F16FR4840 ESDS F16FS4840 ESDS F16FR40316 ESDS F16FS40316 * s may vary by regions. 2

5 EonStor DS Fibre Head Fibre to Fibre Head The 1Uprofile ESDS FFR4031 and ESDS FFS4031 controller heads feature 4Gb/s FC channels and support up to 224 drives. With scalability to expansion enclosures, both secure and costeffective storage can be achieved for companies managing high volumes of data transactions on FC drives and secondtier capacity on SATA drives. ESDS FFR Gb/s FC to 4Gb/s FC Redundant RAID Heads ESDS FFS Gb/s FC to 4Gb/s FC SingleUPG RAID Heads Expansion Channels*2 via Builtin LAN Cache Backup*4 1U Rackmount ASIC Channels / 4Gb/s FC. Each channel has two (2) SFP ports (PBC). Each channel model has builtin HUB which links the two(2) controllers and two(2) SFP ports in one(1) loop. Every channel can be assigned as host or drive channel mode, dualloop Enabled Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models) Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: use friendly menu for accessing all functions and features via telnet. 2 (2) x 250 W 1GB 2GB DDR (PC3200 DDR400) BBU Single controller upgradeable to redundant 86F40RE6CDMA (INC x 2 ) 86F40RE6CDMB (OPT) 86F40RE6CDMA (INC x 1 ) 86F40RE6CDMB (OPT) Fan Module Power Supply Module Channel IO Module RS232C Cable 9276CFanMod (INC x 2) 9276CPSU (INC x 2) 9276CF4HIO2(INC x 6) 9270AYCab (INC x 1) 9270ASCab (INC x 1) UPS Cable 9270CUPSYCab (OPT) 9270CUPSCab (OPT) RS232C Null Modem 9011 (INC x 1) Fibre SFP 9270CSFP4GA01(OPT) Cable 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9276CSlider36 (OPT) DDRESCEMA ( 1GB, INC x 2) DDRESCMB ( 2GB, OPT) DDRESCEMA (1GB, INC x 1) DDRESCMB ( 2GB, OPT) BBU or CBM*4 Installation Guide*6 (INC x 2) 9276CBTE (OPT) (INC x 1) 9276CBTE (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 3

6 EonStor DS Fibre Host The ESDS F16FR4840 is a FibretoFibre storage system featuring 8Gb/s Fibre Channel (FC) host connectivity. The dualcontroller ESDS F16FR4840 enables SMBs to costeffectively deploy highavailability FC SAN delivering outstanding priceperformance. Its enterpriseclass data protection and exceptional performance are ideal for missioncritical environments. Fibre to Fibre RAID System R2 ESDS F16FR4840 8Gb/s FC to 4Gb/s FC RAID Subsystems ESDS F16FS4840 8Gb/s FC to 4Gb/s FC RAID Single Upgrade Subsystems ESDS F16FR Gb/s FC to 4Gb/s FC RAID Subsystems ESDS F16FS Gb/s FC to 4Gb/s FC RAID Single Upgrade Subsystems Expansion Channels*2 via Builtin LAN Cache Backup*4 16 Channels / 16bay FC 4Gb/s drives 2(Embedded in PSU) (2) x 530 W 1GB 4GB DDRII CBM or BBU 3U 16bay. 4 Channels / 8 Gb/s FC. 2 Channels / 8 Gb/s FC. Each channel has two (2) SFP ports. Each channel has two (2) SFP ports ASIC Channels / 4Gb/s FC. Each channel has two (2) SFP ports (PBC). Each channel model has builtin HUB which links the two (2) controllers and two(2) SFP ports in one (1) loop Four (4) 4 Gb/s FC SFP ports Single controller upgradable Single controller upgradable Enabled Enabled to redundant to redundant Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models) Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) (2) x 530 W 1GB 2GB DDR (PC3200 DDR400) BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray Channel IO Module RS232C Cable UPS Cable RS232C Null Modem Fibre SFP Cable BBU or CBM*4 Installation Guide*6 83 FF48RF16DA (INC x 2) 83 FF48RF16DA(INC x 1) 83FF48RF16DB(OPT) 83FF48RF16DB(OPT) 83FF48RF16DC(OPT) 83FF48RF16DC(OPT) 9373AYCAB ( INC x 1) DDR2RECMA (1GB, INC x 2) x CPSU (INC x 2) 9373F4DIO2L (INC x 1) 9373F4DIO2L (INC x 1) 9370CSFP8G ( OPT) 9270CSFP4GA01(OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) 9373CCBM (INC x 2) 9373CCBM (INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 4 83F40REC6DMA (INC x 2 ) 83F40REC6DMB (OPT ) 9273ECFanMod (INC x 2) 9273ECPSU (INC x 2) 83F40REC6DMA (INC x 1) 83F40REC6DMA (OPT) 9273CF4HIO2L (INC x 1) 9273CF4HIO2R(INC x 1) 9273F4DIO4L (INC x 1) 9273F4DIO4R (INC x 1) 9270AYCab (INC x 1) 9270ASCab (INC x 1) 9270CUPSYCab (OPT ) 9270CUPSCab (OPT) 9011 (INC x 1) DDRESCEMA (1GB, INC x 2) DDRESCMB (2GB, OPT) x CBTE (OPT) 9270CSFP4GA01 (OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9273CSlider32 (OPT) 9273CSlider36 (OPT) DDRESCEMA (1GB, INC x 1) DDRESCMB (2GB, OPT) x CBTE (OPT) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

7 EonStor DS Fibre Host EonStor DS G7 EonStor DS G7 systems are the latest addition to Infortrend's EonStor DS family. With today's price points in mind, EonStor DS G7 provides a powerful architecture to ensure SMBs and enterprises can easily meet the requirements of missioncritical applications and can flexibly scale storage capacity to more than 200 drives to accommodate growing needs. Coupled with highavailability features, advanced hardware, modular design, and easy and intuitive management, EonStor DS G7 offers organizations a decisive competitive edge by pushing IT efficiency to previously unattainable levels. Fibre to SAS RAID System ESDS S24FR2850 8Gb/s FC to SAS RAID G7 ESDS S24FG2850 8Gb/s FC to SAS RAID G7 Expansion Channels*2 via Builtin LAN Cache Backup*4 4U24 Bay Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. G7 24 Channels / 24bay Exclusively SAS 6Gb/s drives 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF8088) per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled 2 (2) x 405 W 4GB 8GB DDRIII CBM Accessory Variations (INC:, OPT: Optional) 84SF28RG24MC (INC x 2) 84SF28RG24MD (OPT) 84SF28GG24MC (INC x 1) 84SF28GG24MD (OPT) FAN Module Power Supply Module Drive Tray 9374CFanMod (INC x 2) 9274CPSU (INC x 3) 9373CDTray (INC x 24) RS232C Cable Cable Cable for SAS expansion BBU or CBM*4 Installation Guide*6 9373AYCAB (INC x 1) DDR3RECMB (2GB, INC x 2) DDR3RECMC (4GB, OPT) 9383CCBM (INC x 2) 9383CBBU (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab9 (OPT) 9373ASCAB (OPT) DDR3RECMB (2GB, INC x 1) DDR3RECMC (4GB, OPT) 9383CCBM (OPT) 9383CBBU (OPT) * 4. EonStor DS G7 models only support CBM, and G7 models do not support BBU alone.

8 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S16FR2850 is a Fibre Channel (FC) host storage system combining 8Gb/s FC host connectivity and 6Gb/s SAS drive support. Accommodating 16 drives, the dualcontroller ESDS S16FR2850 enables enterprises to deploy highavailability FC SANs and offers exceptional performance ideal for missioncritical environments. The system can be easily scaled to more than 200 drives to meet growing business needs. ESDS S16FR2850 8Gb/s FC to SAS RAID ESDS S16FG2850 8Gb/s FC to SAS RAID ESDS S12FR2850 8Gb/s FC to SAS RAID ESDS S12FG2850 8Gb/s FC to SAS RAID G7 G7 G7 G7 Expansion Channels*2 via Builtin LAN Two (2) SAS 6Gb/s 4x wide port (SFF8088) 3U16 Bay G7 16 Channels / 16bay Exclusively SAS 6Gb/s drives 4 Channels / 8Gb/s FC Four (4) 8Gb/s FC SFPs per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 2U12 Bay G7 12 Channels / 12bay Exclusively SAS 6Gb/s drives One (1) SAS 6Gb/s 4x wide port (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 4 Channels / 8Gb/s FC Four (4) 8Gb/s FC SFPs per controller Cache Backup*4 2 (Embedded in PSU) (2) x 530 W 4GB 8GB DDRIII CBM 2 (Embedded in PSU) (2) x 530 W 4GB 8GB DDRIII CBM Accessory Variations (INC:, OPT: Optional) 83SF28RG16MC (INC x 2) 83SF28RG16MD (OPT) 83SF28GG16MC (INC x 1) 83SF28GG16MD (OPT) 85SF28RG12MC (INC x 2) 85SF28RG12MD (OPT) 85SF28GG12MC (INC x 1) 85SF28GG12MD (OPT) FAN Module Power Supply Module Drive Tray RS232C Cable Cable Cable for SAS expansion 9373AYCAB (INC x 1) 9373CPSU (INC x 2) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9373ASCAB (OPT) 9373CPSU (INC x 2) 9373CDTray (INC x 12) 9270CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab9 (OPT) 9373AYCAB (INC x 1) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab9 (OPT) 9373ASCAB (OPT) DDR3RECMB (2GB, INC x 2) DDR3RECMC (4GB, OPT) DDR3RECMB (2GB, INC x 1) DDR3RECMC (4GB, OPT) DDR3RECMB (2GB, INC x 2) DDR3RECMC (4GB, OPT) DDR3RECMB (2GB, INC x 1) DDR3RECMC (4GB, OPT) BBU or CBM*4 Installation Guide*6 9383CCBM (INC x 2) 9383CBBU (OPT) 9383CCBM (OPT) 9383CBBU (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues CCBM (INC x 2) 9383CBBU (OPT) 9383CCBM (OPT) 9383CBBU (OPT) * 4. EonStor DS G7 models only support CBM, and G7 models do not support BBU alone.

9 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S48FR2842 is a highdensity, 48bay storage system. With hybrid connectivity including Fibre Channel (FC) and iscsi ports, the dualcontroller ESDS S48FR2842 enables SMBs to deploy highavailability FC SANs delivering outstanding priceperformance and achieve highly costeffective remote replication with iscsi ports. The large storage capacities of the ESDS S48FR2842 are ideal for applications such as data archiving and HPC. ESDS S48FR Gb/s FC to SAS RAID ESDS S48FG Gb/s FC to SAS RAID Expansion Channels*2 via Builtin LAN Cache Backup*4 Two (2) SAS 6Gb/s 4x wide port (SFF8088) 4U48 Bay 48 Channels / 48bay Exclusively SAS 6Gb/s drives 4 Channels / 8G b/s FC & 2 Channels / GbE Four (4) 8Gb/s FC SFPs & Two (2) RJ45 ports per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled 3 (Embedded in PSU) (3) x 530 W 1GB 4GB DDRII CBM or BBU Accessory Variations (INC:, OPT: Optional) 84SF28RF48MA (INC x 2) 84SF28RF48MB (OPT) 84SF28RF48MC (OPT) 84SF28GF48MA (INC x 1) 84SF28GF48MB (OPT) 84SF28GF48MC (OPT) FAN Module Drawer Fan Module Power Supply Module Drive Tray RS232C Cable Cable 9474FAN (INC x 3) 9474PSU (INC x 3) 9474Locker (INC x 48) 9373AYCAB ( INC x 1) 9373ASCAB (OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9474CSlider36 (INC) BBU or CBM*4 DDR2RECMA (1GB, INC x 2) 9373CBBU ( OPT) 9373CCBM (INC x 2) DDR2RECMA (1GB, INC x 1) Installation Guide*6 * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 7

10 EonStor DS Fibre Host Fibre to SAS RAID System Designed for telecommunications, military, and oil and gas industry environments, the ESDS S12FR2840N is a 8Gb/s Fibre Channel (FC) host storage system featuring DC power supplies. The dualcontroller system enables users to deploy highavailability FC SANs delivering outstanding priceperformance, and its enterpriseclass data protection and exceptional performance are ideal for missioncritical environments. ESDS S12FR2840N 8Gb/s FC to SAS RAID ESDS S12FG2840N 8Gb/s FC to SAS RAID Expansion Channels*2 via Builtin LAN Cache Backup*4 Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 2U12 Bay 12 Channels / 12bay Exclusively SAS 6Gb/s drives 4 Channels / 8G b/s FC Four (4) 8Gb/s FC SFPs per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) (2) x 530 DC 1GB 4GB DDRII CBM or BBU One (1) SAS 6Gb/s 4x wide port (SFF8088) Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive Tray MUX board RS232C Cable Fibre SFP Cable BBU or CBM*4 Installation Guide*6 85SF28RF12NMA (INC x 2) 85SF28RF12NMB (OPT) 85SF28RF12NMC (OPT) 9373CDTray (INC x 12) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) 9273NPSU (INC x 2) 9373AYCAB ( INC x 1) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 85SF28RF12NMA (INC x 1) 85SF28RF12NMB (OPT) 85SF28RF12NMC (OPT) 9373CDTray (INC x 12) DDR2RECMA (1GB, INC x 1) 9373CCBM (INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 8 * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

11 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S16FR2842 is a hybrid model featuring both Fibre Channel (FC) ports and iscsi ports. The dualcontroller ESDS S16FR2842 enables SMBs to deploy highavailability FC SANs delivering outstanding priceperformance and achieve highly costeffective remote replication with the iscsi ports. The enterpriseclass data protection and exceptional performance of the ESDS S16FR2842 are ideal for missioncritical environments. ESDS S16FR Gb/s FC to SAS RAID ESDS S16FG Gb/s FC to SAS RAID ESDS S24FR Gb/s FC to SAS RAID ESDS S24FG Gb/s FC to SAS RAID Expansion Channels*2 via Builtin LAN 3U16 Bay 16 Channels / 16bay Exclusively SAS 6Gb/s drives 4 Channels / 8G b/s FC & 2 Channels / GbE Four (4) 8Gb/s FC SFPs & Two (2) RJ45 ports per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 4U24 Bay 24 Channels / 24bay Exclusively SAS 6Gb/s drives 4 Channels / 8G b/s FC Four (4) 8Gb/s FC SFPs per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. Cache Backup*4 2 (Embedded in PSU) (3) x 530 W 1GB 4GB DDRII CBM or BBU 2 (3) x 405 W 1GB 4GB DDRII CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive Tray MUX board RS232C Cable Fibre SFP Cable BBU or CBM*4 Installation Guide*6 83SF28RF166DA (INC x 2) 83SF28RF166DB (OPT) 83SF28RF166DC (OPT) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) 9373AYCAB (INC x 1) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) 9373CPSU (INC x 2) 9370CSFP8G (OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 83SF28GF166DA (INC x 1) 83SF28GF166DB (OPT) 83SF28GF166DC (OPT) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 9 84SF28RF244DA (INC x 2) 84SF28RF244DB (OPT) 84SF28RF244DC (OPT) 9373CDTray (INC x 24) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) 9373AYCAB ( INC x 1) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) 9374CFanMod (INC x 2) 9274CPSU (INC x 3) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 84SF28GF244DA (INC x 1) 84SF28GF244DB (OPT) 84SF28GF244DC (OPT) 9373CDTray (INC x 24) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

12 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S16FR2840 is a Fibre Channel (FC) host storage system combining 8Gb/s FC host connectivity and 6Gb/s SAS drive support. Accomodating 16 SAS drives, the dualcontroller ESDS S16FR2840 enables SMBs to costeffectively deploy highavailability FC SANs delivering outstanding priceperformance. The enterpriseclass data protection and exceptional performance of the ESDS S16FR2840 are ideal for missioncritical environments. ESDS S16FR Gb/s FC to SAS RAID ESDS S16FG Gb/s FC to SAS RAID ESDS S12FR Gb/s FC to SAS RAID ESDS S12FG Gb/s FC to SAS RAID Expansion Channels*2 via Builtin LAN 3U16 Bay 4 Channels / 8G b/s FC Four (4) 8Gb/s FC SFPs per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 16 Channels / 16bay Exclusively SAS 6Gb/s drives One (1) SAS 6Gb/s 4x wide port (SFF8088) Two (2) SAS 6Gb/s 4x wide port (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models) Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2U12 Bay 12 Channels / 12bay Exclusively SAS 6Gb/s drives 4 Channels / 8Gb/s FC Four (4) 8Gb/s FC SFPs per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled 2 (Enbedded in PSU) (2) x 530 W 1GB 4GB DDRII 2 (Embedded in PSU) 2 (2) x 530 W (2) x 350 W 1GB 4GB DDRII Cache Backup*4 Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray RS232C Cable Fibre SFP Cable BBU or CBM*4 Installation Guide*6 83SF28RF164DA (INC x 2) 83SF28RF164DB (OPT) 83SF28RF164DC (OPT) 9373AYCAB ( INC x 1) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) CBM or BBU 9373CPSU (INC x 2) 83SF28GF164DA (INC x 2) 83SF28GF164DB (OPT) 83SF28GF164DC (OPT) MUX board 9373CMUX3G (OPT) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) 85SF28RF124DA (INC x 2) 85SF28RF124DB (OPT) 85SF28RF124DC (OPT) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) CBM or BBU 82SF28GF124DA (INC x 1) 82SF28GF124DB (OPT) 82SF28GF124DC (OPT) 9272CPSU (INC x 2) 9373CPSU (INC x 2) 9372CFanModE(INC x 2) 9373CDTray (INC x 12) 9373CMUX3G (OPT) 9373CDTray (INC x 12) 9373AYCAB ( INC x 1) 9373ASCAB (OPT) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) DDR2RECMA (1GB, INC x 1) 9373CCBM(OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 10 * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

13 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S24FR1840 is a Fibre Channel (FC) host storage system featuring 8Gb/s FC host connectivity. Accomodating 24 SAS drives, the dualcontroller ESDS S24FR1840 helps SMBs deploy highavailability FC SANs delivering outstanding priceperformance. The enterpriseclass data protection and exceptional performance of the ESDS S24FR1840 are ideal for missioncritical environments. ESDS S24FR Gb/s FC to SAS RAID ESDS S24FG Gb/s FC to SAS RAID ESDS S16FR Gb/s FC to SAS RAID ESDS S16FG Gb/s FC to SAS RAID 4U24 Bay 24 Channels / 24bay Exclusively SAS drives 4 Channels / 8G b/s FC Four (4) 8Gb/s FC SFPs per controller 3U16 Bay 16 Channels / 16bay Exclusively SAS drives 4 Channels / 8G b/s FC Four (4) 8Gb/s FC SFPs per controller Expansion Channels*2 via Builtin LAN Two (2) SAS 4x wide port (SFF8088) Enabled One (1) SAS 4x wide port (SFF8088) Two (2) SAS 4x wide port (SFF8088) Enabled Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. One (1) SAS 4x wide port (SFF8088) Cache Backup*4 2 (3) x 405 W 1GB 4GB DDRII CBM or BBU 2 (Enbedded in PSU) (2) x 530 W 1GB 4GB DDRII CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Fibre SFP Cable BBU or CBM*4 84SF18RF244DA (INC x 2) 84SF18RF244DB (OPT) 84SF18RF244DC (OPT) Drive tray 9373CDTRAY (INC x 24) 9373S1DT2S1S (OPT) 9373CDTray (INC x 24) MUX board 9373S1N2SIS (OPT) RS232C Cable 9373AYCAB ( INC x 1) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) 9374CFanMod (INC x 2) 9274CPSU (INC x 3) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 84SF18GF244DA (INC x 1) 84SF18GF244DB (OPT) 84SF18GF244DC (OPT) DDR2RECMA (1GB, INC x 1) 83SF18RF164DA (INC x 2) 83SF18RF164DB (OPT) 83SF18RF164DC (OPT) DDR2RECMA (1GB, INC x 2) 9373CPSU (INC x 2) 9373S1DT2S1S (OPT) 9373S1N2SIS (OPT) 9373AYCAB ( INC x 1) 9373ASCAB (OPT) 9373CCBM (INC x 2) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 83SF18GF164DA (INC x 1) 83SF18GF164DB (OPT) 83SF18GF164DC (OPT) DDR2RECMA (1GB, INC x 1) Installation Guide*6 * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 11 * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

14 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S16FR1840 is a Fibre Channel (FC) host storage system featuring 8Gb/s FC host connectivity. Accomodating 16 SAS drives, the dualcontroller ESDS S16FR1840 enables SMBs to costeffectively deploy highavailability FC SANs delivering outstanding priceperformance. The enterpriseclass data protection and performance of the ESDS S16FR1840 are ideal for missioncritical environments. ESDS S12FR Gb/s FC to SAS RAID ESDS S12FG Gb/s FC to SAS RAID ESDS S24FR1440 4Gb/s FC to SAS RAID ESDS S24FG1440 4Gb/s FC to SAS RAID 2U12 Bay 12 Channels / 12bay Exclusively SAS drives 4 Channels / 8G b/s FC Four (4) 8G FC SFPs per controller 4U24 Bay 24 Channels / 24bay Exclusively SAS drives 2 Channels / 4G b/s FC Two (2) 4Gb/s FC SFPs per controller Expansion Channels*2 via Builtin LAN Two (2) SAS 4x wide port (SFF8088) Enabled One (1) SAS 4x wide port (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. Two (2) SAS 4x wide port (SFF8088) One (1) SAS 4x wide port (SFF8088) Enabled 2 (Embedded in PSU) 2 2 (2) x 530 W (2) x 350 W (3) x 405 W 1GB 4GB DDRII 1GB 4GB DDRII Cache Backup*4 CBM or BBU CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray RS232C Cable Fibre SFP Cable BBU or CBM*4 Installation Guide*6 85SF18RF124DA (INC x 2) 85SF18RF124DB (OPT) 85SF18RF124DC (OPT) 9373CPSU (OPT) 9373CDTray (INC x 12) 9373S1DT2S1S (OPT) MUX board 9373S1N2SIS (OPT) 9373AYCAB ( INC x 1) DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 82SF18GF124DA (INC x 1) 82SF18GF124DB (OPT) 82SF18GF124DC (OPT) 9372CFanModE (INC x 2) 9272CPSU (INC x 2) 9373CDTray (INC x 12) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) 84SF14RF24DMA (INC x 2) 84SF14RF24DMB (OPT) 84SF14RF24DMC (OPT) 9373CDTray (INC x 24) 9373S1DT2S1S (OPT) 9373S1N2SIS (OPT) DDR2RECMA (1GB, INC x 2) 9373CCBM ( OPT) 9373CBBU (INC x 2) 9374CFanMod (INC x 2) 9274CPSU (INC x 3) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 84SF14GF24DMA (INC x 1) 84SF14GF24DMB (OPT) 84SF14GF24DMC (OPT) 9373AYCAB ( INC x1) 9373ASCAB (OPT) 9270CSFP4GA01 ( OPT) 9373CDTray (INC x 24) DDR2RECMA (1GB, INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 12 * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

15 EonStor DS Fibre Host Fibre to SAS RAID System The ESDS S16FR1440 is a Fibre Channel (FC) host storage system featuring 4Gb/s FC host connectivity. Accomodating 16 SAS drives, the dualcontroller ESDS S16FR1440 enables SMBs to costeffectively deploy highavailability FC SANs. The enterpriseclass data protection and performance of the ESDS S16FR1440 are ideal for missioncritical environments. ESDS S16FR1440 4Gb/s FC to SAS RAID ESDS S16FG1440 4Gb/s FC to SAS RAID ESDS S12FR1440 4Gb/s FC to SAS RAID ESDS S12FG1440 4Gb/s FC to SAS RAID 3U16 Bay 16 Channels / 16bay Exclusively SAS drives 2U12 Bay 12 Channels / 12bay Exclusively SAS drives Expansion Channels*2 via Builtin LAN Two (2) SAS 4x wide port (SFF8088) Enabled 2 Channels / 4Gb/s FC Two (2) 4Gb/s FC SFPs per controller One (1) SAS 4x wide port (SFF8088) Two (2) SAS 4x wide port (SFF8088) 2 Channels / 4G b/s FC Two (2) 4G FC SFPs per controller One (1) SAS 4x wide port (SFF8088) Enabled Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. Cache Backup*4 2 (Embedded in PSU) (2) x 530 W 1GB 4GB DDRII CBM or BBU 2 (Embedded in PSU) 3 (2) x 530 W (2) x 350 W 1GB 4GB DDRII CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray RS232C Cable Fibre SFP Cable BBU or CBM*4 Installation Guide*6 83SF14RF161DA (INC x 2) 83SF14RF161DB (OPT) 83SF14RF161DC (OPT) 9373S1DT2S1S (OPT) 9373AYCAB ( INC x 1) DDR2RECMA (1GB, INC x 2) 9373CBBU (INC x 2 ) 9373CPSU (INC x 2) 9270CSFP4GA01 ( OPT) 83SF14GF161DA (INC x 1) 83SF14GF161DB (OPT) 83SF14GF161DC (OPT) MUX board 9373S1N2SIS (OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) 85SF14RF12DMA (INC x 2) 85SF14RF12DMB (OPT) 85SF14RF12DMC (OPT) 9373CPSU (INC x 2) 9272CPSU (INC x 2) 9373CDTray (INC x 12) 9373S1DT2S1S (OPT) 9373S1N2SIS (OPT) 9373AYCAB ( INC x 1) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 2) 9373CBBU (INC x 2) 9270CSFP4GA01 ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 85SF14RF121DA (INC x 2) 85SF14RF121DB (OPT) 85SF14RF121DC (OPT) 9372CFanMod1 (INC x 3) 9373CDTray (INC x 12) DDR2RECMA (1GB, INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 13 * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

16 EonStor DS SAS Host SAS to SAS RAID System The ESDS S04SG2240 is a lowcost, 6Gb/s SASbased storage system ideal for SMBs with limited storage capacity demand. Accommodating four drives, the ESDS S04SG2240 helps SMBs easily deploy a highperformance directattached storage (DAS) environment. The enterpriseclass data protection and outstanding priceperformance of the ESDS S04SG2240 are ideal for demanding business applications. R2 ESDS S04SG2240 6Gb/s SAS to SAS RAID Expansion Channels*2 via Builtin LAN Cache Backup*4 1U4 Bay 4 Channels / 4bay Exclusively SAS 6Gb/s drives 2 Channels / SAS 6Gb/s Two (2) SAS 6Gb/s 4x wide ports (SFF8088) per controller Hostside redundant path and load balancing supported (EonPath software required in the host computers), switched fabric support, fabric login (supported on fibrehost model). Dualmode RAID expansion "Addin Drive" and "Copy & Replace with large drive" Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse menu for accessing all functions and features. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite. (Storage management, central view, and Notification manager via , LAN broadcast, SNMP trap, MSN and fax) Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: Userfriendly menudriven for accessing all function and feature via telnet. 2 (2) 200 W 1GB 4GB DDRII BBU or CBM Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray MUX board RS232C Cable Cable BBU or CBM*4 Installation Guide*6 87SS22GDC2MA (INC x 1) 87SS22GDC2MB (OPT) 87SS22GDC2MC (OPT) 9277CFanMod (INC x 2) 9277CPSU (INC x 2) 9373CDTray (INC x 4) 9373ASCab (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab7 (OPT) 9277CSlider36 (INC) DDR2RECMA (1GB, INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 14

17 EonStor DS SAS Host SAS to SAS RAID System The ESDS S24SG2240 is a 6Gb/s SASbased storage system that helps SMBs easily deploy a highperformance directattached storage (DAS) environment. Accommodating 24 SAS drives, the singlecontroller ESDS S24SG2240 delivers optimal performance. The enterpriseclass data protection and outstanding priceperformance of the ESDS S24SG2240 are ideal for demanding business applications. R2 ESDS S16SR Gb/s SAS to SAS RAID ESDS S16SG Gb/s SAS to SAS RAID ESDS S24SG Gb/s SAS to SAS RAID ESDS S24SG2240 6Gb/s SAS to SAS RAID Expansion Channels*2 via Builtin LAN Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 3U16 Bay 16 Channels / 16bay Exclusively SAS 6Gb/s drives 2 Channels / SAS 6Gb/s & 2 Channels / GbE Two (2) SAS 6Gb/s 4x wide ports (SFF8088) & Two (2) RJ45 ports per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) Hostside redundant path and load balancing supported (EonPath software required in the host computers), switched fabric support, fabric login (supported on fibrehost model). Dualmode RAID expansion "Addin Drive" and "Copy & Replace with large drive" Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse menu for accessing all functions and features. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite. (Storage management, central view, and Notification manager via , LAN broadcast, SNMP trap, MSN and fax) Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: Userfriendly menudriven for accessing all function and feature via telnet. 4 Channels / SAS 6Gb/s Four (4) SAS 6Gb/s 4x wide ports (SFF8088) per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) 4U24 Bay 24 Channels / 24bay Exclusively SAS 6Gb/s drives 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide port (SFF8088) per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) 2 (Embedded in PSU) 2 2 (2) x 530 W (3) x 405 W (3) x 405 W 1GB 4GB DDRII 1GB 4GB DDRII 1GB 4GB DDRII Cache Backup*4 BBU or CBM BBU or CBM BBU or CBM Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray MUX board RS232C Cable Cable BBU or CBM*4 Installation Guide*6 83SE22RF224A (INC x 2) 83SE22RF224B (OPT) 83SE22RF224C (OPT) 9373CMUX3GTRP (OPT) 9373AYCab ( INC x 1) 9373CBBU (INC x 2) 9373CPSU (INC x 2) 83SE22GF224A (INC x 1) 83SE22GF224B (OPT) 83SE22GF224C (OPT) 9373CMUX3G (OPT) 9270CmSASCab8 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 2) 9373ASCab (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues S22GF244DA (INC x 1) 84S22GF244DB (OPT) 84S22GF244DC (OPT) 9374CFanMod (INC x2) 9274CPSU (INC x 3) 9373CDTray (INC x 24) 9373ASCab (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 1) 84S22GF24DMA (INC x 1) 84S22GE24DMB (OPT) 84S22GE24DMC (OPT) 9374CFanMod (INC x2) 9274CPSU (INC x 3) 9373CDTray (INC x 24) 9373ASCab (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

18 EonStor DS SAS Host SAS to SAS RAID System The ESDS S16SR22404 is a 6Gb/s SASbased storage system that helps SMBs support even more server applications in their directattached storage (DAS) environments with eight SAS host ports in a dualcontroller configuration. The enterpriseclass data protection and outstanding priceperformance of the ESDS S16SR22404 are ideal for demanding business applications. R2 ESDS S16SR Gb/s SAS to SAS RAID ESDS S16SG Gb/s SAS to SAS RAID ESDS S12SR Gb/s SAS to SAS RAID ESDS S12SG Gb/s SAS to SAS RAID Expansion Channels*2 Two (2) SAS 6Gb/s 4x wide port (SFF8088) 3U16 Bay 16 Channels / 16bay Exclusively SAS 6Gb/s drives 4 Channels / SAS 6Gb/s Four (4) SAS 6Gb/s 4x wide ports (SFF8088) per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) 2U12 Bay 12 Channels / 12bay Exclusively SAS 6Gb/s drives 4 Channels / SAS 6Gb/s Four (4) SAS 6Gb/s 4x wide ports (SFF8088) per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) One (1) SAS 6Gb/s 4x wide port (SFF8088) via Builtin LAN Enabled Hostside redundant path and load balancing supported (EonPath software required in the host computers), switched fabric support, fabric login (supported on fibrehost model). Dualmode RAID expansion "Addin Drive" and "Copy & Replace with large drive" Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse menu for accessing all functions and features. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite. (Storage management, central view, and Notification manager via , LAN broadcast, SNMP trap, MSN and fax) Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: Userfriendly menudriven for accessing all function and feature via telnet. Enabled 2 (Embedded in PSU) 2 (Embedded in PSU) 2 (2) x 530 W (2) x 530 W (2) x 350 W Cache Backup*4 1GB 4GB DDRII BBU or CBM 1GB 4GB DDRII BBU or CBM Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray MUX board RS232C Cable Cable BBU or CBM*4 Installation Guide*6 83S22RF16DMA (INC x 2) 83S22RF16DMB (OPT) 83S22RF16DMC (OPT) 9373CMUX3GTRP (OPT) 9373CPSU (INC x 2) 9373CMUX3G (OPT) 9373AYCab ( INC x 1) 9373ASCab (OPT) 9270CmSASCab8 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 2) 9373CBBU (INC x 2) 83S22GF16DMA (INC x 1) 83S22GF16DMB (OPT) 83S22GF16DMC (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues S22RF124DMA (INC x 2) 85S22RF124DMB (OPT) 85S22RF124DMC (OPT) 9372CFanModE (INC x 2) 9373CPSU (INC x 2) 9272CPSU (INC x 2) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) 9373AYCAB (INC x 1) 9270CmSASCab8 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 2) 9373CBBU (INC x 2) 82S22GF124DMA (INC x 1) 82S22GF124DMB (OPT) 82S22GF124DMC (OPT) 9373ASCAB (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 1) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

19 EonStor DS SAS Host SAS to SAS RAID System The ESDS S16SR2240 is a 6Gb/s SASbased storage system that helps SMBs easily deploy a highperformance directattached storage (DAS) environment. Accommodating 16 SAS drives, the dualcontroller ESDS S16SR2240 delivers optimal performance. The enterpriseclass data protection and outstanding priceperformance of the ESDS S16SR2240 are ideal for demanding business applications. R2 ESDS S16SR2240 6Gb/s SAS to SAS RAID ESDS S16SG2240 ESDS S12SR2240 ESDS S12SG2240 6Gb/s SAS to SAS RAID 6Gb/s SAS to SAS RAID 6Gb/s SAS to SAS RAID Expansion Channels*2 via Builtin LAN 3U16 Bay 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide port (SFF8088) per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 16 Channels / 16bay Exclusively SAS 6Gb/s drives One (1) SAS 6Gb/s 4x wide port (SFF8088) 12 Channels / 12bay Exclusively SAS 6Gb/s drives Hostside redundant path and load balancing supported (EonPath software required in the host computers), switched fabric support, fabric login (supported on fibrehost model). Dualmode RAID expansion "Addin Drive" and "Copy & Replace with large drive" Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse menu for accessing all functions and features. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite. (Storage management, central view, and Notification manager via , LAN broadcast, SNMP trap, MSN and fax) Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: User friendly menudriven for accessing all function and feature via telnet. 2U12 Bay 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide port (SFF8088) per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled 2 (Embedded in PSU) 2 (Embedded in PSU) 2 Cache Backup*4 (2) x 530 W 1GB 4GB DDRII BBU or CBM (2) x 530 W (2) x 350 W 1GB 4GB DDRII BBU or CBM Accessory Variations (INC:, OPT: Optional) 83S22RF16DMA (INC x 2) 83S22RF16DMB (OPT) 83S22RF16DMC (OPT) Cooling Module Power Supply Module Drive tray RS232C Cable Cable BBU or CBM*4 Installation Guide*6 9373CMUX3GTRP (OPT) 9373AYCab ( INC x 1) 9270CmSASCab2 (INC X 2) 9270CmSASCab1 (OPT) DDR2RECMA (1GB, INC x 2) DDR2RECMB(OPT) DDR2RECMC(OPT) 9373CBBU (INC x 2) 9373CPSU (INC x 2) MUX board 9373CMUX3G (OPT) 83S22GF16DA (INC x 1) 83S22GF16DB (OPT) 83S22GF16DC (OPT) 83S22RF12DMA (INC x 2) 83S22RF12DMB (OPT) 83S22RF12DMC (OPT) 9373CPSU (INC x 2) 83S22GF12DMA (INC x 1) 83S22GF12DMB (OPT) 83S22GF12DMC (OPT) 9272CPSU (INC x 2) 9373CDTray (INC x 12) 9373ASCab (OPT) 9373AYCab ( INC x 1) 9373ASCab (OPT) 9270CmSASCab2 (INC X 1) 9270CmSASCab1 (OPT) DDR2RECMA (1GB, INC x 1) DDR2RECMB(OPT) DDR2RECMC(OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 9373CDTray (INC x 12) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) 9270CmSASCab2 (INC X 2) 9270CmSASCab2 (INC X 1) 9270CmSASCab1 (OPT) 9270CmSASCab1 (OPT) DDR2RECMA (1GB, INC x 2) DDR2RECMB(OPT) DDR2RECMC(OPT) 9373CBBU (INC x 2) 9372CFanModE (INC x 2) DDR2RECMA (1GB, INC x 1) DDR2RECMB(OPT) DDR2RECMC(OPT) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 17

20 Eonstor DS iscsi Host iscsi to SAS RAID System Featuring 10GbE iscsi host connectivity and 6Gb/s SAS drive support, the ESDS S16ER/G2240 models provide a budgetfriendly choice to help SMB users easily deploy highavailability IP SANs. Accommodating 16 SAS drives, the dualcontroller ESDS S16ER2240 and singlecontroller ESDS S16EG2240 deliver optimal performance. Their enterpriseclass data protection and outstanding priceperformance can generate significant business advantages. R2 ESDS S16ER2240 iscsi to SAS RAID systems ESDS S16EG2240 iscsi to SAS RAID Expansion Channels*2 via Builtin LAN Cache Backup*4 Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 3U16 Bay 16 Channels / 16bay Exclusively SAS 6Gb/s drives 2 Channels / 10GbE Two (2) SFP+ ports per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) (2) x 530 W 1GB 4GB DDRII CBM or BBU One (1) SAS 6Gb/s 4x wide port (SFF8088) Accessory Variations (INC:, OPT: Optional) Cooling Module 83SE22RF16DMA (INC x 2) 83SE22RF16DMB (OPT) 83SE22RF16DMC (OPT) 83SE22GF16DMA (INC x 1) 83SE22GF16DMC (OPT) 83SE22GF16DMC (OPT) Power Supply Module Drive tray RS232C Cable RS232C Null Modem BBU or CBM*4 Installation Guide*6 9373CMUX3GTRP (OPT) 9373AYCAB (INC x 1) 9373CPSU (INC x 2) MUX board 9373CMUX3G (OPT) Fibre SFP DDR2RECMA (1GB, INC x 2) 9373CCBM (INC x 2) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 9370CSFP10G (OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9373ASCAB (OPT) DDR2RECMA (1GB, INC x 1) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 18

21 Eonstor DS iscsi Host iscsi to SAS RAID System Featuring 1GbE iscsi host connectivity and 6Gb/s SAS drive support, the ESDS S16ER2142 provides a budgetfriendly choice to help SMB users easily deploy highavailability IP SANs. Accommodating 16 SAS drives, the dualcontroller ESDS S16ER2142 delivers optimal performance. The enterpriseclass data protection and outstanding priceperformance of the ESDS S16ER2142 can generate significant business advantages. R2 ESDS S24EG21426 iscsito SAS RAID ESDS S16ER21426 iscsi to SAS RAID ESDS S16EG21426 iscsi to SAS RAID ESDS S12ER21404 iscsi to SAS RAID 4U24 Bay 3U16 Bay 2U12 Bay 24 Channels / 24bay Exclusively SAS 6Gb/s drives 16 Channels / 16bay Exclusively SAS 6Gb/s drives 12 Channels / 12bay Exclusively SAS 6Gb/s drives Expansion Channels*2 via Builtin LAN 6 Channels / GbE Six (6) RJ45 ports per controller One (1) SAS 6Gb/s 4x wide ports (SFF8088) Two (2) SAS 6Gb/s 4x wide ports (SFF8088) Enabled 6 Channels / GbE Six (6) RJ45 ports per controller One (1) SAS 6Gb/s 4x wide ports (SFF8088) Enabled Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 4 Channels / GbE Four (4) RJ45 ports per controller Two (2) SAS 6Gb/s 4x wide ports (SFF8088) 2 2 (Embedded in PSU) 2 (Embedded in PSU) (3) 405W (2) x 530 W (2) x 530 W 1GB 4GB DDRII 1GB 4GB DDRII 1GB 4GB DDRII Cache Backup*4 CBM or BBU CBM or BBU CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray MUX board RS232C Cable BBU or CBM*4 84SE21GF246DA (INC x 1) 84SE21GF246DB (OPT) 84SE21GF246DC (OPT) 9374CFanMod (INC x 2) 9274CPSU (INC x 3) 9373CDTray (INC x 24) 83SE21RF166DA (INC x 2) 83SE21RF166DB (OPT) 83SE21RF166DC (OPT) 9373CPSU (INC x 2) 9373CMUX3GTRP(OPT) 9373CMUX3G (OPT) 9273ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) 9373AYCab ( INC x 1) DDR2RECMA (INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) 9373CBBU (INC x 2) 83SE21GF166DA (INC x 1) 83SE21GF166DB (OPT) 83SE21GF166DC (OPT) 9373CPSU (INC x 2) 9373ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) 82SE21RF124DA (INC x 2) 82SE21RF124DB (OPT) 82SE21RF124DC (OPT) 9373CPSU (INC x 2) 9373CDTray (INC x 12) 9373CMUX3GTRP(OPT) 9373CMUX3G (OPT) 9373AYCab ( INC x 1) DDR2RECMA (INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) 9373CBBU (INC x 2) Installation Guide*6 * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 19

22 Eonstor DS iscsi Host iscsi to SAS RAID System The ESDS S16EG1140 is a 1GbE iscsihost storage system that provides a budgetfriendly choice to help SMBs easily deploy IP SANs. Accommodating 16 SAS drives, the singlecontroller ESDS S16EG1140 delivers optimal performance. The enterpriseclass data protection and outstanding priceperformance of the ESDS S16EG1140 can generate significant business benefits. R2 ESDS S12EG21404 ESDS S16ER11404 ESDS S16EG11404 ESDS S12EG11402 iscsi to SAS RAID iscsi to SAS RAID systems iscsi to SAS RAID iscsi to SAS RAID Expansion Channels*2 via Builtin LAN 2U12 Bay 12 Channels / 12bay Exclusively SAS 6Gb/s drives 4 Channels / GbE Four (4) RJ45 ports per controller One (1) SAS 6Gb/s 4x wide ports (SFF8088) 3U16 Bay 16 Channels / 16bay Exclusively SAS drives 4 Channels / GbE Four (4) RJ45 per controller Two (2) SAS 4x wide port (SFF8088) Enabled 3U16 Bay 2U12 Bay Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 16 Channels / 16bay 12 Channels / 12bay Exclusively SAS drives Exclusively SAS drives 4 Channels / GbE Four (4) RJ45 ports per controller One (1) SAS 4x wide ports (SFF8088) 2 Channels / GbE Two (2) RJ45 ports per controller One (1) SAS 4x wide port (SFF8088) 2 2 (Embedded in PSU) 2 (Embedded in PSU) 3 (2) x 350 W (2) x 530 W (2) x 530 W (2) x 350 W 1GB 4GB DDRII Cache Backup*4 CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module 82SE21GF124DA (INC x 1) 82SE21GF124DB (OPT) 82SE21GF124DC (OPT) 9372CFanMode (INC x 2) 83SE11RF16BA (INC x 2) 83SE11RF16BB (OPT) 83SE11RF16BC (OPT) 83SE11GF164DA (INC x 1) 83SE11GF164DB (OPT) 83SE11GF164DC (OPT) 82SE11GF122DA (INC x 1) 82SE11GF122DB (OPT) 82SE11GF122DC (OPT) 9372CFanMod1 (INC x 3) Power Supply Module Drive tray MUX board RS232C Cable BBU or CBM*4 Installation Guide*6 9272CPSU(INC x 2) 9373CDTray (INC x 12) 9373ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) 9273NPSU (INC x 2) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) 9373AYCAB (INC X 1) DDR2RECMA (1GB, INC x 2) 9373CBBU (INC x 2) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 9373CPSU (INC x 2) 9373ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) 9272CPSU (INC x 2) 9373CDTray (INC x 12) 9373ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 20

23 EonStor DS Expansion Enclosure The ESDS S48SJ2000R is a 6Gb/s SASbased expansion enclosure that accommodates 48 drives in a 4U form factor and features redundant power supplies and cooling modules. The expansion enclosure allows users to easily attach many terabytes of capacity to the ESDS S48FR2842. The ESDS S48S J2000R provides faulttolerant links across separate SAS domains. ESDS S48SJ2000R SAS Systems ESDS S48SJ2000G SAS Systems Expansion Channels*2 via Builtin LAN Cache Backup*4 4U48 Bay 48 Channels / 48bay Exclusively SAS 6Gb/s drives 2 Channels / SAS 6Gb/s 2 Channels / SAS 6Gb/s Two (2) 4x wide ports (SFF8088) per per controller Two (2) 4x wide ports (SFF8088) per per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: use friendly menu for accessing all functions and features via telnet. 3 (Embedded in PSU) (3) x 530 W Accessory Variations (INC:, OPT: Optional) Fan Module Drawer Fan Module Power Supply Module 84SS20J48 (INC x 2) 84SS20J48 (INC x 1) 9474FAN (INC x 3) 9474PSU (INC x 3) Drive Tray MUX board RS232 Cable Cable Rackmount Kits*5 Cache Momery*3 BBU or CBM*4 Installation Guide*6 9270CmSASCab7 (INC x 2) 9270CmSASCab8 (OPT) 9270CmSASCab9 (OPT) 9474Locker (INC) 9474CSlider36 (INC) 9270CmSASCab7 (INC x 1) 9270CmSASCab8 (OPT) 9270CmSASCab9 (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 21

24 EonStor DS Expansion Enclosure The ESDS S12SJ2000RN is a 6Gb/s SASbased expansion enclosure that accommodates 12 drives in a compact 2U form factor and features redundant DC power supplies and redundant cooling modules. The expansion enclosure allows users of the ESDS S12FR2840N to easily attach terabytes of capacity to their storage system. The ESDS S12SJ2000RN provides faulttolerant links across separate SAS domains. ESDS S12SJ2000RN SAS Systems ESDS S12SJ2000SN SAS Systems Expansion Channels*2 via Builtin LAN 2U12 Bay 12 Channels / 12bay Exclusively SAS 6Gb/s drives 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF8088) per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: use friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) (2) x 530 W DC Cache Backup*4 Accessory Variations (INC:, OPT: Optional) 85S20J122N (INC x 2) 85S20J122N (INC x 1) Cooling Module Power Supply Module Drive tray MUX board Cable Instillation Guide*6 9373CDTray (INC x 12) 9373CMUX3GTRP (OPT) 9373NPSU (INC x 2) 9373CDTray (INC x 12) 9373CMUX3G (OPT) 9270CmSASCab1 (INC x 2) 9270CmSASCab1 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab2 (OPT) CD (INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 22

25 EonStor DS Expansion Enclosure Infortrend EonStor DS expansion enclosures deliver high reliability and density. Through SAS expansion ports, users can quickly and easily connect the enclosures to EonStor DS storage systems for flexible capacity expansion. The incremental approach of capacity scaling effectively satisfies growing application needs while reducing wasted upfront investment. ESDS S16SJ2000R SAS Systems ESDS S16SJ2000S ESDS S12SJ2000R ESDS S12SJ2000G SAS Systems SAS Systems SAS Systems 3U16 Bay 2U12 Bay 16 Channels / 16bay Exclusively SAS 6Gb/s drives 12 Channels / 12bay Exclusively SAS 6Gb/s drives Expansion Channels*2 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF8088) per controller via Builtin LAN Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: use friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) 2 (Embedded in PSU) 2 (2) x 530 W (2) x 530 W (2) x 350 W Cache Backup*4 Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray 83S20J162D (INC x 2) 83S20J162D (INC x 1) 9373CMUX3GTRP (OPT) 9373 CPSU (INC x 2) MUX board 9373CMUX3G (OPT) 85S20J122D (INC x 2) 82S20J122D (INC x 1) 9373CPSU (INC x 2) 9373CDTray (INC x 12) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT) 9272CFanMod (INC x 3) 9272CPSU (INC x 2) 9373CDTray (INC x 12) Cable 9270CmSASCab1 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab9 (OPT) 9270CmSASCab1 (INC x 1) 9270CmSASCab9 (OPT) 9270CmSASCab2 (INC x 2) 9270CmSASCab1 (OPT) 9270CmSASCab9 (OPT) 9270CmSASCab2 (INC x 1) 9270CmSASCab1 (OPT) 9270CmSASCab9 (OPT) Instillation Guide*6 CD (INC x 1) CD (INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 23

26 EonStor DS Expansion Enclosure Expansion enclosures to meet growing capacity demand Various drive size options to suit your capacity requirements High availability with redundant hardware components Easy to deploy, install and manage ESDS S16SJ1000R ESDS S16SJ1000S ESDS S12SJ1002R ESDS S12SJ1000G Expansion Enclosure Expansion Enclosure Drive Channels *1 Expansion Channels*2 via Builtin LAN 3U16 Bay 16 Channels / 16bay Exclusively SAS drives 2U12 Bay 12 Channels / 12bay Exclusively SAS drives 2 Channels / SAS 3Gb/s 2 Channels / SAS 3Gb/s 2 Channels / SAS 3Gb/s 2 Channels / SAS 3Gb/s Two (2) SAS 4x wide ports (SFF8470) Two (2) SAS 4x wide ports (SFF8470) Two (2) SAS 4x wide ports (SFF8088) Two (2) SAS 4x wide ports (SFF8470) per controller per controller per controller per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) 2 (Embedded in PSU) 2 (2) x 530 W (2) x 530 W (2) x 460 W Battery Backup*4 Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray 83S10J162D (INC x 2) 83S10J162D (INC x 1) 89S10J122D(INC x 2) 85S10J12C2D (INC x 1) 9373S1DT2S1S (OPT) 9273ECFanMod (INC x 2) 9273ECPSU (INC x 2) MUX board 9373S1N2SIS (OPT) 9279CFanMod (INC x 2) 9279CPSU (INC x 2) 9373CDTray (INC x 12) 9373S1DT2S1S (OPT) 9373S1N2SIS (OPT) 9275ECFanMod (INC x 2) 9275ECPSU (INC x 2) 9373CDTray (INC x 12) Cable 9270CmSASCab3 (INC x 2) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT) 9270CSASCab01 (OPT) 9270CSASCab02 (OPT) 9270CmSASCab3 (INC x 1) 9270CmSASCab3 (INC x 1) 9270CmSASCab4 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab1 (INC x 2) 9270CmSASCab5 (OPT) 9270CmSASCab5 (OPT) 9270CmSASCab2 (OPT) 9270CSASCab01 (OPT) 9270CSASCab01 (OPT) 9270CSASCab02 (OPT) 9270CSASCab02 (OPT) 9273CSlider32 (OPT) 9273CSlider36 (OPT) 9279CSlider36 (OPT) 9272CESlide28 (OPT) 9272CESlide36 (OPT) Installation Guide*6 CD (INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 24

27 EonStor DS 2.5" Drive Fiber Host Fibre to 2.5" SAS RAID System The ESDS B24FR2842 is a smallformfactor (SFF) hybrid model featuring both Fibre Channel (FC) and iscsi ports. The dualcontroller ESDS B24FR2842 enables SMBs to deploy highavailability 8Gb/s FC SAN and achieve costeffective remote replication with the iscsi ports. Accommodating 24 SFF drives in a 2U enclosure, it delivers optimal performance density. The system s enterpriseclass data protection and performance are ideal for missioncritical environments. R2 ESDS B24FR Gb/s FC to 2.5"SAS RAID ESDS B24FG Gb/s FC to 2.5"SAS RAID ESDS B24FR Gb/s FC to 2.5"SAS RAID ESDS B24FG Gb/s FC to 2.5"SAS RAID Expansion Channels*2 via Builtin LAN Cache Backup*4 4 Channels / 8G b/s FC & 2 Channels / GbE Four (4) 8Gb/s FC SFPs & Two (2) RJ45 ports per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enable One (1) SAS 6Gb/s 4x wide port (SFF8088) 2U24 Bay 24 Channels / 24bay Exclusively 2.5 SAS drives 1GB 4GB DDRII CBM or BBU Two (2) SAS 6Gb/s 4x wide ports (SFF8088) Enabled 4 Channels / 8G b/s FC Four (4) 8Gb/s FC SFPs per controller One (1) SAS 6Gb/s wide port 4x (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) (2) x 530 W Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray RS232C Cable Fibre SFP Cable 8BBF28RF246DA (INC x 2) 8BBF28RF246DB (OPT) 8BBF28RF246DC (OPT) 9ACETray (INC x 24) 9ACTRAYMUX3G (OPT) 9373AYCAB (INC x 1) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) DDR2RECMA (1GB, INC x 2) 8BBF28GF246DA (INC x 1) 8BBF28GF246DB (OPT) 8BBF28GF246DC (OPT) 9ACETray (INC x 24) MUX board 9ACMUX3G (OPT) 9373ASCAB (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab2 (OPT) DDR2RECMA (1GB, INC x 1) 9CCPSU (INC x 2) 9370CSFP8G (OPT) 9CCSlider36 (INC) 8BBF28RF244DA (INC x 2) 8BBF28RF244DB(OPT) 8BBF28RF244DC (OPT) 9ACETray (INC x 24) 9ACTRAYMUX3G (OPT) 9ACMUX3G (OPT) 9373AYCab ( INC x 1) DDR2RECMA (INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 8BBF28GF244DA (INC x 1) 8BBF28GF244DB(OPT) 8BBF28GF244DC (OPT) 9ACETray (INC x 24) 9373ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) BBU or CBM*4 9373CCBM (INC x 2) 9373CCBM (INC x 2) Installation Guide*6 * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 25 * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

28 EonStor DS 2.5" Drive Fiber/SAS Host The ESDS B24SR2242 is a smallformfactor (SFF) hybrid storage system featuring 6Gb/s SAS and 1GbE iscsi connectivity. The dualcontroller ESDS B24SR2242 enables SMBs to deploy a highperformance directattached storage (DAS) environment and achieve remote replication via the iscsi ports. Accommodating 24 SFF drives in a 2U enclosure, it delivers optimal performance density. The system's enterpriseclass data protection and outstanding performance can generate significant business advantages. Fibre/ SAS to 2.5" SAS RAID System R2 ESDS B12FR28404 ESDS B12FG28404 ESDS B24SR22424 ESDS B24SG Gb/s FC to 2.5"SAS RAID 8Gb/s FC to 2.5"SAS RAID 4Gb/s FC to 2.5"SAS RAID 4Gb/s FC to 2.5"SAS RAID Expansion Channels*2 via Builtin LAN Two (2) SAS 6Gb/s 4x wide port (SFF8088) Enabled 1U12 Bay 12 Channels / 12bay Exclusively 2.5 SAS drives 4 Channels / 8G FC Four (4) 8G FC SFPs per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. Enabled 24 Channels / 24bay Exclusively 2.5" SAS drives 2 Channels / SAS 6Gb/s & 2 Channels / GbE Two (2) SAS 6Gb/s 4x wide ports (SFF8088) & Two (2) RJ45 ports per controller Two (2) SAS 6Gb/s 4x wide port (SFF8088) 2U24 Bay One (1) SAS 6Gb/s 4x wide port (SFF8088) 2 2 (Embedded in PSU) (2) x 380 W (2) x 250 W (2) x 530 W Cache Backup*4 1GB 4GB DDRII CBM or BBU 1GB 4GB DDRII CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module Drive tray Fibre SFP Cable BBU or CBM*4 Installation Guide*6 8ABF28RF124DA (INC x 2) 8ABF28RE124DB (OPT) 8ABF28RE124DC (OPT) 9ACPSU (INC x 2) 9ACETray (INC x 12) 9ACTRAYMUX3G (OPT) MUX board 9ACMUX3G (OPT) RS232C Cable 9270AYCab ( INC x 1) 9270ASCab (OPT) DDR2RECMA (1GB, INC x 2) DDR2RECMB (OPT) DDR2RECMC(OPT) 9ACCBM (INC x 2) 9ACBBU (OPT) 9ACFanMod1 (INC x 2) 9370CSFP8G ( OPT) 9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9277CSlider36 (INC) 8ABF28GF124DA (INC x 1) 8ABF28GF124DB (OPT) 8ABF28GF124DC (OPT) 9271CPSU (INC x 2) 9ACETray (INC x 12) DDR2RECMA (1GB, INC x 1) DDR2RECMB (OPT) DDR2RECMC(OPT) 9ACCBM (OPT)) 9ACBBU (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 26 8BBS24RF224A (INC x 2) 8BBS24RF224B (OPT) 8BBS24RF224C (OPT) 9ACETray (INC x 24) 9ACTRAYMUX3G (OPT) 9ACMUX3G (OPT) 9373AYCAB (INC x 1) 9270CmSASCab8 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 2) 9373CBBU (INC x 2) 9CCPSU (INC x 2) 9CCSlider36 (INC) 8BBS24GF224A (INC x 1) 8BBS24GF224B (OPT) 8BBS24GF224C (OPT) 9ACETray (INC x 24) 9373ASCAB (OPT) 9270CmSASCab8 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab1 (OPT) 9270CmSASCab7 (OPT) DDR2RECMA (1GB, INC x 1) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

29 EonStor DS 2.5" Drive SAS Host SAS to 2.5" SAS RAID System The ESDS B24SR2240 is a 6Gb/s SASbased storage system that helps SMBs easily deploy a directattached storage (DAS) environment. Accommodating 24 small form factor (SFF) 2.5 inch drives in a highdensity 2U enclosure, the dualcontroller ESDS B24SR2240 delivers optimal performance density. Its enterpriseclass data protection and outstanding performance can generate significant business advantages. R2 ESDS B24SR2240 6Gb/s SAS to 2.5"SAS RAID ESDS B24SG2240 6Gb/s SAS to 2.5"SAS RAID ESDS B12SR2240 6Gb/s SAS to 2.5"SAS RAID ESDS B12SG2240 6Gb/s SAS to 2.5"SAS RAID Expansion Channels*2 2U24 Bay 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide port (SFF8088) per controller Two (2) SAS 6Gb/s 4x wide ports (SFF8088) 24 Channels / 24bay Exclusively 2.5 SAS drives One (1) SAS 6Gb/s wide port 4x (SFF8088) Enabled Two (2) SAS 6Gb/s 4x wide ports (SFF8088) Enabled 1U12 Bay 12 Channels / 12bay Exclusively 2.5 SAS drives 2 Channels / SAS 6Gb/s Two (2) SAS 4x wide port (SFF8088) per controller One (1) SAS 6Gb/s wide port 4x (SFF8088) Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). via Builtin LAN Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) 2 (2) x 530 W (2) x 380 W (2) x 250 W 1GB 4GB DDRII 1GB 4GB DDRII Cache Backup*4 CBM or BBU CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module RS232C Cable Fibre SFP Cable BBU or CBM*4 Installation Guide*6 8BBS22RF24DMA (INC x 2) 8BBS22RF24DMB (OPT) 8BBS22RF24DMC (OPT) Power Supply Module 9CCPSU (INC x 2) Drive tray 9ACETray (INC x 24) 9ACTRAYMUX3G (OPT) 9ACETray (INC x 24) MUX board 9ACMUX3G (OPT) 9373AYCab ( INC x 1) 9373ASCab (OPT) 9270CmSASCab2 (INC x 2) 9270CmSASCab2 (INC x 1) 9270CmSASCab1 (OPT) 9270CmSASCab1 (OPT) DDR2RECMA (INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) 9373CBBU (INC x 2) 9CCSlider36 (INC) 8BBS22GF24DMA (INC x 1) 8BBS22GF24DMB (OPT) 8BBS22GF24DMC (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 27 8ABS22RF12DMA (INC x 2) 8ABS22RF12DMB (OPT) 8ABS22RF12DMC (OPT) 9ACPSU (INC x 2) 9ACETray (INC x 12) 9ACTRAYMUX3G (OPT) 9ACMUX3G (OPT) 9373AYCab ( INC x 1) 9270CmSASCab2 (INC x 2) 9270CmSASCab1 (OPT) DDR2RECMA (INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) 9373CBBU (INC x 2) 9ACFanMod1 (INC x 2) 9277CSlider36 (INC) 8ABS22GF12DMA (INC x 1) 8ABS22GF12DMB (OPT) 8ABS22GF12DMC (OPT) 9271CPSU (INC x 2) 9ACETray (INC x 12) 9373ASCab (OPT) 9270CmSASCab2 (INC x 1) 9270CmSASCab1 (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages

30 EonStor DS 2.5" Drive iscsi Host iscsi to 2.5" SAS RAID System The ESDS B12ER2140 provides excellent space and energy efficiency to help SMBs easily deploy budgetfriendly IP SANs. Accommodating 12 small form factor (SFF) 2.5inch drives in a highdensity 1U enclosure, the dualcontroller ESDS B12ER2140 delivers optimal performance density. Its enterpriseclass data protection and outstanding priceperformance can generate significant business advantages. R2 ESDS B24ER21426 iscsi to 2.5"SAS RAID ESDS B24EG21426 iscsi to 2.5"SAS RAID ESDS B12ER21404 iscsi to 2.5"SAS RAID ESDS B12EG21404 iscsi to 2.5"SAS RAID Expansion Channels*2 via Builtin LAN Two (2) SAS 6Gb/s 4x wide ports (SFF8088) Enabled 2U24 Bay 24 Channels / 24bay Exclusively 2.5 SAS drives 6 Channels / GbE Six (6) RJ45 ports per controller One (1) SAS 6Gb/s wide port 4x (SFF8088) Two (2) SAS 6Gb/s 4x wide port (SFF8088) 1U12 Bay 12 Channels / 12bay Exclusively 2.5 SAS drives Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 4 Channels / GbE Four (4) RJ45 ports per controller One (1) SAS 6Gb/s 4x wide port (SFF8088) Enabled Cache Backup*4 2 (Embedded in PSU) (2) x 530 W 1GB 4GB DDRII CBM or BBU (2) x 380 W (2) x 250 W 2 1GB 4GB DDRII CBM or BBU Accessory Variations (INC:, OPT: Optional) Cooling Module Power Supply Module 9CCPSU (INC x 2) Drive tray 9ACETray (INC x 24) 9ACTRAYMUX3G (OPT) 9ACETray (INC x 24) MUX board 9ACMUX3G (OPT) RS232C Cable BBU or CBM*4 Installation Guide*6 8BBE21RF246DA (INC x 2) 8BBE21RF246DB (OPT) 8BBE21RF246DC (OPT) 9373AYCab ( INC x 1) DDR2RECMA (INC x 2) DDR2RECMB (OPT) DDR2RECMC (OPT) 9373CBBU (INC x 2) 9CCSlider36 (INC) 8BBE21GF246DA (INC x 1) 8BBE21GF246DB (OPT) 8BBE21GF246DC (OPT) 9373ASCab (OPT) DDR2RECMA (INC x 1) DDR2RECMB (OPT) DDR2RECMC (OPT) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. 8ABE21RF124DA (INC x 2) 8ABE21RF124DB (OPT) 8ABE21RF124DC (OPT) 9ACPSU (INC x 2) 9ACETray (INC x 12) 9ACTRAYMUX3G (OPT) 9ACMUX3G (OPT) DDR2RECMA (1GB, INC x 2) DDR2RECMB (OPT) DDR2RECMC(OPT) 9ACBBU (INC x 2) 9ACCBM (OPT) 9ACFanMod1 (INC x 2) 8ABE21GF124DA (INC x 2) 8ABE21GF124DB (OPT) 8ABE21GF124DC (OPT) 9271CPSU (INC x 2) 9ACETray (INC x 12) 9270AYCab ( INC x 1) 9270ASCab (OPT) 9277CSlider36 (INC) DDR2RECMA (1GB, INC x 1) DDR2RECMB (OPT) DDR2RECMC(OPT) 9ACCBM (OPT)) 9ACBBU (OPT) * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 28

31 EonStor DS 2.5" Drive Expansion Enclosure The ESDS B24SJ2000R is a 6Gb/s SASbased expansion enclosure that accommodates 24 small form factor (SFF) drives in a compact 2U enclosure and features redundant power supplies and cooling modules. The expansion enclosure allows users to easily attach terabytes of capacity to Infortrend storage systems. The ESDS B24SJ2000R provides faulttolerant links across separate SAS domains. ESDS B24SJ2000R SAS Systems ESDS B24SJ2000S SAS Systems Expansion Channels*2 2 Channels / SAS 6Gb/s Two (2) SAS 6Gb/s 4x wide ports (SFF8088) per controller 2U24 Bay 24 Channels / 24bay Exclusively 2.5 SAS drives 2 Channels / SAS 6Gb/s Two (2) SAS 6Gb/s 4x wide ports (SFF8088) per controller via Builtin LAN Battery Backup*4 Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. 2 (Embedded in PSU) (2) x 530 W Accessory Variations (INC:, OPT: Optional) 8BBS20J24D (INC x 2) 8BBS20J24D (INC x 1) Fan Module Power Supply Module Drive tray MUX board Cable Installtion Guide*6 9ACETray (INC x 24) 9ACTRAYMUX3G (OPT) 9ACMUX3G (OPT) 9CCPSU (INC x 2) CD (INC x 1) 9ACETray (INC x 24) 9270CmSASCab1 (INC x 2) 9270CmSASCab1 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab7 (OPT) 9270CmSASCab7 (OPT) 9270CmSASCab8 (OPT) 9270CmSASCab8 (OPT) 9CCSlider36 (INC) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 29

32 EonStor DS 2.5" Drive Expansion Enclosure The ESDS B12SJ2000R is a 6Gb/s SASbased highdensity expansion enclosure that accommodates 12 small form factor (SFF) drives in a compact 1U enclosure featuring redundant power supplies and cooling modules. The expansion enclosure allows users to easily attach terabytes of capacity to Infortrend storage systems. The ESDS B12SJ2000R provides faulttolerant links across separate SAS domains. ESDS B12SJ2000R ESDS B12SJ2000G ESDS B12SJ1000R ESDS B12SJ1000S SAS Systems SAS Systems SAS Systems SAS Systems Expansion Channels*2 via Builtin LAN 2 Channels / SAS 6Gb/s Two (2) SAS 6Gb/s 4x wide ports (SFF8088) per controller 1U12 Bay 12 Channels / 12bay Exclusively 2.5 SAS drives 2 2 Channels / SAS 3Gb/s Two (2) SAS 4x wide ports (SFF8088) per controller Hostside redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric login (supported on fibrehost models). Dualmode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Autosync firmware and configuration on replacement controller LCD front panel: Easytouse tool for accessing system functions and features that does not require software installation or management server. RS232 Terminal: User friendly menudriven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including , LAN broadcast, SNMP trap, MSN and fax). Embedded RAIDWatch: Storage management, event notifications ( , SNMP trap, etc.) via HTTP. Telnetterminal: user friendly menu for accessing all functions and features via telnet. (2) x 380 W (2) x 250 W (2) x 380 W Battery Backup*4 Accessory Variations (INC:, OPT: Optional) Fan Module Power Supply Module Drive tray Cable 8ABS20J122D (INC x 2) 8ABS20J122D (INC x 1) 9ACPSU (INC x 2) 9ACETray (INC x 12) 9ACTRAYMUX3G (OPT) 9270CmSASCab1 ( INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab7 (OPT) 9270CmSASCab8 (OPT) 9ACFanMod1 (INC x 2) 8ABS10J122D (INC x 2) 9ACETray (INC x 12) 9ACTRAYMUX3G (OPT) 9ACFanMod (INC x 2) 9271CPSU (INC x 2) 9ACPSU (INC x 2) 9ACETray (INC x 12) MUX board 9ACMUX3G (OPT) 9270CmSASCab1 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab7 (OPT) 9270CmSASCab8 (OPT) 9AS1N2S1S (OPT) 9270CmSASCab1 (INC x 2) 9270CmSASCab2 (OPT) 8ABS10J122D (INC x 1) 9ACETray (INC x 12) 9270CmSASCab1 (INC x 1) 9270CmSASCab2 (OPT) 9277CSlider36 (INC) 9277CSlider36 (OPT) Installtion Guide*6 CD (INC x 1) * 1. Hostside dualloop is supported by using multipath software on the OS or EonPath to provide path redundancy. Driveside dualloop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dualloops. * 2. SAS expansion ports connect SAS when there is a need to expand system capacity. * 3. We do not recommend using 3rdparty memory module due to compatibility issues. * 4. BBU (Battery Backup Unit): provides power to cache memory during power outages 30

33 Connection Topology 32 Shipping Reference 43 Rackmount Kits 45 SANWatch Overview 47 Warranty & Quality 48 Alliance Partner 49

34 CH0 CH0 CH0 CH1 CH1 CH1 High Capacity Guide ESDS F16FR/S4031+ ESDS F16FR/S4031 (3U, 16 Disks) ESDS F16FJ4000R ES F16FJ4000R + = Up to 224 Disks Up to 42U Height (Up to 13 units)(3u, 16 Disks each) Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels. ESDS F16FR/S4031+ ES A16FJ2430G ESDS F16FR/S4031 (3U, 16 Disks) ESDS F16FR4840 (3U, 16 Disks) Fibre Disk Based ES A16FJ2430G + = Up to 224 Disks Up to 42U Height (Up to 13 units)(3u, 16 Disks each) Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels. ESDS F16FR/S4840+ ES F16FJ4000R ESDS F16FS4840 (3U, 16 Disks) ES F16FJ4000R + = Up to 112 Disks Up to 21U Height (Up to 6 units) (3U, 16 Disks each) ES F16FJ4000R + = Up to 112 Disks Up to 21U Height (Up to 6 units) (3U, 16 Disks each) Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels. ESDS F16FR/S4840+ ES A16FJ2430G (SATAII 3Gb/s Drives) ESDS F16FR4840 (3U, 16 Disks) ESDS F16FS4840 (3U, 16 Disks) ES A16FJ2430G + = Up to 112 Disks Up to 21U Height (Up to 6 units) (3U, 16 Disks each) ES A16FJ2430G + = Up to 112 Disks Up to 21U Height (Up to 6 units) (3U, 16 Disks each) Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels. Cables and SFPs: 1. Fibre optical cables and SFPs are not included in the above models; they should be purchased separately. 2. At least 512MB cache memory is required in each RAID controller, when there are more than 96 disks in the configuration. 3. Host channels: Generally two LCLC optical cables and four SFP modules, may vary by host connections. 4. Drive channels: Each F16FJ4000R unit requires at least two LCLC optical cables and four SFP modules. RAID System Connections ESDS F16FR4031 SBOD Link 1 SBOD Link 2 ESDS FFR/S4031+ ESDS F16FJ4000R ESDS FFR/S4031 (1U, no Disks) ESDS F16FJ4000R (Up to 14 units)(3u, 16 Disks each) SFP and Cables Accessories 9270CSFP4GA01: Agilent Fibre Channel 4.25 / / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9370CSFP8G: Avago Fibre Channel 8.5 / 4.25 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9270CFCCab01: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meter 9270CmSASCab1: SAS external cable, 50 cm(sff8088 to SFF8088) 9270CmSASCab2: SAS external cable, 120 cm(sff8088 to SFF8088) 9270CmSASCab3: SAS external cable, 50 cm(sff8470 to SFF8088) 9270CmSASCab4: SAS external cable, 120 cm(sff8470 to SFF8088) 9270CmSASCab5: SAS external cable, 170 cm(sff8470 to SFF8088) 9270CmSASCab6: SAS external cable, 170 cm(sff8088 to SFF8088) 9270CSASCab01: SAS external cable, 50 cm(sff8470 to SFF8470) 9270CSASCab02: SAS external cable, 120 cm(sff8470 to SFF8470) SBODs Connections ESDS F16FJ4000R Connecting to the RAID 's Drive Channels Drive Drive ChannelA ChannelB RAID System Fibre Host + = Up to 224 Disks Up to 43U Height Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels. ESDS FFR/S4031 (1U, no Disks) Fibre Head ESDS FFR/S4031+ ESDS A16FJ2430G ESDS A16FJ2430G (Up to 6 units)(3u, 16 Disks each) + = Up to 96 Disks Up to 7U Height Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels. 0 ESDS F16FS4031 SBOD Link 1 SBOD Link 2 1 SBOD ESDS F16FR4840 SBOD Link 1 SBOD Link 2 2 SBOD 3 SBOD ESDS F16FS4840 SBOD Link 1 SBOD Link 2 4 SBOD ESDS FFR4031/ESDS FFS4031 SBOD Link 1 5 SBOD 6 SBOD SBOD Link 2 32

35 High Capacity Guide Fibre to SAS RAID Systems Fibre / SAS/ iscsi Host ESDS S48FR/G ESDS S48SJ2000R/G ESDS S48FR (4U, 48 Disks) ESDS S48FG (4U, 48 Disks) ESDS S12FR2840N + (2U, 12 Disks) ESDS S24FR/G ESDS S16SJ2000R/S ESDS S24FR28404 (4U, 24 Disks) + ESDS S24FG (4U, 24 Disks) ESDS S16SJ2000R = Up to 104 Disks Up to 19U Height (Up to 5 units)(3u, 16 Disks each) ESDS S16SJ2000S = Up to 104 Disks Up to 19U Height (Up to 5 units)(3u, 16 Disks each) ESDS S24FR/G18404/1440+ ESDS S16SJ1000R/S ESDS S24FR18404/1440 ESDS S16SJ1000R = Up to 104 Disks Up to 19U Height (4U, 24 Disks) + (Up to 5 units)(3u, 16 Disks each) ESDS S24FG18404/1440 ESDS S16SJ1000S = Up to 104 Disks Up to 19U Height (4U, 24 Disks) + (Up to 5 units)(3u, 16 Disks each) ESDS S16FR/G ESDS S16SJ2000R/S ESDS S16FR28426 (3U, 16 Disks) ESDS S16FG28426 (3U, 16 Disks) + + ESDS S48SJ2000R (Up to 4 units)(4u, 48 Disks) ESDS S48SJ2000G (Up to 4 units)(4u, 48 Disks) ESDS S12FR/S2840N + ESDS S12SJ2000RN/SN ESDS S12SJ2000RN (Up to 6 units)(2u, 12Disks) ESDS S12FS2840N + ESDS S12SJ2000SN (2U, 12 Disks) + (Up to 6 units)(2u, 12Disks) = Up to 240 Disks Up to 20U Height = Up to 240 Disks Up to 20U Height =Up to 84 Disks =Up to 84 Disks Up to 14U Height Up to 14U Height ESDS S16SJ2000R = Up to 112 Disks Up to 21U Height (Up to 6 units)(3u, 16 Disks each) ESDS S16SJ2000S = Up to 112 Disks Up to 21U Height (Up to 6 units)(3u, 16 Disks each) ESDS S16FR/G ESDS S16SJ2000R/S ESDS S16FR28404 (3U, 16 Disks) + ESDS S16FG28404 (3U, 16 Disks) + ESDS S16SR18404/1440 ESDS (3U, 16 Disks) + ESDS S12FR28404 (2U, 12 Disks) + ESDS S16SJ2000R = Up to 112 Disks Up to 21U Height (Up to 6 units)(3u, 16 Disks each) ESDS S16SJ2000S = Up to 112 Disks Up to 21U Height (Up to 6 units)(3u, 16 Disks each) ESDS S16FR/G18404/1440+ ESDS S16SJ1000R/S S16SJ1000R (Up to 6 units)(3u, 16 Disks each) ESDS S12FR/G ESDS S12SJ2000R/G = Up to 112 Disks Up to 21U Height ESDS S16FG18404/1440 ESDS S16SJ1000S = Up to 112 Disks Up to 21U Height (3U, 16 Disks) + (Up to 6 units)(3u, 16 Disks each) ESDS S12SJ2000R = Up to 84 Disks Up to 14U Height (Up to 6 units)(2u, 12 Disks each) ESDS S12FG ESDS S12SJ2000G = Up to 84 Disks Up to 14U Height (2U, 12 Disks) (Up to 6 units)(2u, 12 Disks each) ESDS S12FR/G18404/1440+ ESDS S12SJ1002R ESDS S12SR18404/1440 ESDS S12SJ1002R = Up to 84 Disks Up to 14U Height (2U, 12 Disks) + (Up to 6 units)(2u, 12 Disks each) ESDS S12FG18424/1440+ESDS S12SJ1000G ESDS S12SG18424/1440 ESDS S12SJ1000S = Up to 84 Disks Up to 14U Height (2U, 12 Disks) + (Up to 6 units)(2u, 12 Disks each) ESDS S12FR/G ESDS S12SJ2000R/G + ESDS S48SJ2000R/G ESDS S12FR ESDS S12SJ2000R + ESDS S48SJ2000R = Up to 216 Disks Up to 24U Height (2U, 12 Disks) (Up to 5 units)(2u, 12 Disks) (Up to 3 untis)(4u, 48 Disks) ESDS S12FR ESDS S12SJ2000R + ESDS S48SJ2000R = Up to 228 Disks Up to 22U Height (2U, 12 Disks) (Up to 2 units)(2u, 12 Disks) (Up to 4 untis)(4u, 48 Disks) ESDS S12FG ESDS S12SJ2000G + ESDS S48SJ2000G = Up to 216 Disks Up to 24U Height (2U, 12 Disks) (Up to 5 units)(2u, 12 Disks) (Up to 3 untis)(4u, 48 Disks) ESDS S12FG ESDS S12SJ2000G + ESDS S48SJ2000G = Up to 228 Disks Up to 22U Height (2U, 12 Disks) (Up to 2 units)(2u, 12 Disks) (Up to 4 untis)(4u, 48 Disks) ESDS S16FR/G ESDS S16SJ2000R/S + ESDS S48SJ2000R/G ESDS S16FR ESDS S16SJ2000R + ESDS S48SJ2000R = Up to 240 Disks Up to 30U Height (3U, 16 Disks) (Up to 5 units)(3u, 16 Disks) (Up to 3 untis)(4u, 48 Disks) ESDS S16FR ESDS S16SJ2000R + ESDS S48SJ2000R = Up to 240 Disks Up to 25U Height (3U, 16 Disks) (Up to 2 units)(3u, 16 Disks) (Up to 4 untis)(4u, 48 Disks) ESDS S16FG ESDS S16SJ2000S + ESDS S48SJ2000G = Up to 240 Disks Up to 30U Height (3U, 16 Disks) (Up to 5 units)(3u, 16 Disks) (Up to 3 untis)(4u, 48 Disks) ESDS S16FG ESDS S16SJ2000S + ESDS S48SJ2000G = Up to 240 Disks Up to 25U Height (3U, 16 Disks) (Up to 2 units)(3u, 16 Disks) (Up to 4 untis)(4u, 48 Disks) ESDS S24FR/G ESDS S16SJ2000R/S + ESDS S48SJ2000R/G ESDS S24FR ESDS S16SJ2000R + ESDS S48SJ2000R = Up to 200 Disks Up to 27U Height (4U, 24 Disks) (Up to 5 units)(3u, 16 Disks) (Up to 2 untis)(4u, 48 Disks) ESDS S24FR ESDS S16SJ2000R + ESDS S48SJ2000R = Up to 232 Disks Up to 23U Height (4U, 24 Disks) (Up to 1 units)(3u, 16 Disks) (Up to 4 untis)(4u, 48 Disks) ESDS S24FG ESDS S16SJ2000S + ESDS S48SJ2000G = Up to 200 Disks Up to 27U Height (4U, 24 Disks) (Up to 5 units)(3u, 16 Disks) (Up to 2 untis)(4u, 48 Disks) ESDS S24FG ESDS S16SJ2000S + ESDS S48SJ2000G = Up to 232 Disks Up to 23U Height (4U, 24 Disks) (Up to 1 units)(3u, 16 Disks) (Up to 4 untis)(4u, 48 Disks) Cables Accessories 9270CSFP4GA01: Agilent Fibre Channel 4.25/2.125 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9370CSFP8G: Avago Fibre Channel 8.5 / 4.25 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9270CFCCab01: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Mete 9270CSASCab01: SAS external cable, 50 cm (SFF8470 to SFF8470) 9270CSASCab02: SAS external cable, 120 cm (SFF8470 to SFF8470) 9270CmSASCab1 SAS external cable, 50 cm (SFF8088 to SFF8088) 9270CmSASCab2 SAS external cable, 120 cm (SFF8088 to SFF8088) 9270CmSASCab3 SAS external cable, 50 cm (SFF8470 to SFF8088) 9270CmSASCab4 SAS external cable, 120 cm(sff8470 to SFF8088) 9270CmSASCab5 SAS external cable, 170 cm(sff8470 to SFF8088) 9270CmSASCab6 SAS external cable, 170 cm(sff8088 to SFF8088) 9270CmSASCab7 SAS external cable, pull type, 50 cm(sff8088 to SFF8088) 9270CmSASCab8 SAS external cable, pull type, 120 cm(sff8088 to SFF8088) 9270CmSASCab9 SAS external cable, pull type, 260cm(SFF8088 to SFF8088) 33

36 High Capacity Guide SAS to SAS RAID Systems ESDS S24SG ESDS S16SJ2000S ESDS S24SG2240 (4U, 24 Disks) + ESDS S16SJ2000S (up to 5 units)(3u, 16 Disks) = ESDS S24SG ESDS S16SJ2000S ESDS S24SG22404 (4U, 24 Disks) ESDS S16SR/G ESDS S16SJ2000R/S ESDS S16SR2240 (3U, 16 Disks) ESDS S16SG2240 (3U, 16 Disks) ESDS S16SJ2000R + = (up to 6 units)(3u, 16 Disks) Up to 104 Disks Up to 112 Disks Up to 19U Height ESDS S16SJ2000S + (up to 5 units)(3u, 16 Disks) = Up to 104 Disks Up to 19U Height Up to 21U Height + ESDS S16SJ2000S = Up to 112 Disks Up to 21U Height (up to 6 units)(3u, 16 Disks) ESDS S16SR/G ESDS S16SJ2000R/S ESDS S16SR22404 (3U, 16 Disks) ESDS S16SG22404 (3U, 16 Disks) ESDS S16SR/G ESDS S16SJ2000R/S ESDS S16SR22424 (3U, 16 Disks) ESDS S16SG22424 (3U, 16 Disks) ESDS S12SR/G ESDS S12SJ2000R/G ESDS S12SR2240 (2U, 12 Disks) ESDS S12SG2240 (2U, 12 Disks) ESDS S16SJ2000R + = (up to 6 units)(3u, 16 Disks) ESDS S16SJ2000R + = (up to 6 units)(3u, 16 Disks) + ESDS S16SJ2000S = Up to 112 Disks Up to 21U Height (up to 6 units)(3u, 16 Disks) ESDS S12SJ2000R + = (up to 6 units)(2u, 12 Disks) Up to 84 Disks ESDS S12SJ2000G = Up to 84 Disks + (up to 6 units)(2u, 12 Disks) ESDS S12SR/G ESDS S12SJ2000R/G Up to 112 Disks Up to 112 Disks Up to 21U Height + ESDS S16SJ2000S = Up to 112 Disks Up to 21U Height (up to 6 units)(3u, 16 Disks) Up to 21U Height Up to 14U Height Up to 14U Height ESDS S16ER/G ESDS S16SJ2000R/S ESDS S16ER21426 (3U, 16 Disks) + ESDS S16EG21426 (3U, 16 Disks) + iscsi to SAS RAID Systems ESDS S16ER/G ESDS S16SJ2000R/S ESDS S16ER2240 ESDS S16SJ2000R (3U, 16 Disks) + = Up to 112 Disks (up to 6 units)(3u, 16 Disks) ESDS S16EG2240 (3U, 16 Disks) ESDS S16SJ2000R (Up to 6 units) (3U, 16 Disks) = Up to 112 Disks ESDS S16SJ2000S = Up to 112 Disks (Up to 6 units) (3U, 16 Disks) ESDS S12ER/G ESDS S12SJ2000R/G ESDS S12ER21404 ESDS S12SJ2000R (2U, 12 Disks) + = Up to 84 Disks (up to 6 units)(2u, 12 Disks) ESDS S12EG21404 ESDS S12SJ2000G + = Up to 84 Disks (2U, 12 Disks) (up to 6 units)(2u, 12 Disks) ESDS S16ER/G ESDS S16SJ1000R/S ESDS S16ER11404 (3U, 16 Disks) + ESDS S12EG11402 (2U, 12 Disks) + ESDS S16SJ1000R (up to 6 units)(3u, 16 Disks) = Up to 112 Disks ESDS S12EG ESDS S12SJ1000G S24EG21426 (4U, 24 Disks) + ESDS S16SJ2000S = Up to 112 Disks Up to 21U Height (up to 6 units)(3u, 16 Disks) ESDS S12SJ1000G = Up to 84 Disks (up to 6 units)(2u, 12 Disks) ESDS S24EG ESDS S16SJ2000S Up to 21U Height Up to 21U Height Up to 21U Height Up to 14U Height Up to 14U Height Up to 21U Height ESDS S16EG11404 ESDS S16SJ1000S (3U, 16 Disks) + (up to 6 units)(3u, 16 Disks) = Up to 112 Disks Up to 21U Height Up to 14U Height S16SJ2000S + (up to 5 units)(3u, 16 Disks) = Up to 104 Disks Up to 19U Height ESDS S12SR22404 (2U, 12 Disks) + ESDS S12SJ2000R = (up to 6 units)(2u, 12 Disks) Up to 84 Disks Up to 14U Height ESDS S12SG22404 (2U, 12 Disks) + ESDS S12SJ2000G = (up to 6 units)(2u, 12 Disks) Up to 84 Disks Up to 14U Height Cables Accessories 9270CSFP4GA01: Agilent Fibre Channel 4.25/2.125 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9370CSFP8G: Avago Fibre Channel 8.5 / 4.25 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9270CFCCab01: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Mete 9270CSASCab01:SAS external cable, 50 cm (SFF8470 to SFF8470) 9270CSASCab02:SAS external cable, 120 cm (SFF8470 to SFF8470) 9270CmSASCab1SAS external cable, 50 cm (SFF8088 to SFF8088) 9270CmSASCab2SAS external cable, 120 cm (SFF8088 to SFF8088) 9270CmSASCab3SAS external cable, 50 cm (SFF8470 to SFF8088) 9270CmSASCab4SAS external cable, 120 cm(sff8470 to SFF8088) 9270CmSASCab5SAS external cable, 170 cm(sff8470 to SFF8088) 9270CmSASCab6SAS external cable, 170 cm(sff8088 to SFF8088) 9270CmSASCab7SAS external cable, pull type, 50 cm(sff8088 to SFF8088) 9270CmSASCab8SAS external cable, pull type, 120 cm(sff8088 to SFF8088) 34

37 CH0 CH0 CH0 CH0 CH0 CH1 CH1 CH1 CH0 CH1 CH2 CH3 CH1 CH1 CH2 CH2 CH2 CH2 CH2 CH3 CH3 CH3 CH3 CH CH0 CH1 CH2 CH CH0 CH0 CH1 CH1 CH2 CH2 Ctrl Status Ctrl Status CH3 CH3 CBM Status CBM Status High Capacity Guide Fibre / SAS/ iscsi Host 4U RAID Subsystem Connections ESDS S24FR28404 ESDS S24FR18404 ESDS S24FR1440 ESDS S24SG22404 Link 2 Link 2 Link 2 ESDS S24FG28404 ESDS S24FG18404 ESDS S24FG1440 ESDS S24SG2240 ESDS S24EG21426 ESDS S48FR28406 ESDS S48FG28426 ESDS S24FR28404 Link 2 Link 2 ESDS S24FR2850 ESDS S24FG2850 Link 2 35

38 Ctrl Status Ctrl Status Ctrl Status Ctrl Status Ctrl Status Ctrl Status Ctrl Status CH0 CH1 CH2 CH3 CH0 CH1 CH2 CH3 Ctrl Status Ctrl Status High Capacity Guide Fibre / SAS/ iscsi Host 3U RAID Subsystem Connections ESDS S16SG22404 ESDS S16FG28426 ESDS S16FG28404 ESDS S16FG18404 CBM Status ESDS S16FG1440 ESDS S16ER11404 ESDS S16EG11404 ESDS S16ER21426 CBM Status CBM Status CBM Status Link 2 Link 2 ESDS S16FR1440 ESDS S16SR2240 ESDS S16EG2240 ESDS S16ER2240 CBM Status CBM Status CBM Status CBM Status CBM Status Link 2 Link 2 Link 2 ESDS S16FR2850 ESDS S16FG2850 Link 2 36

39 Fibre / SAS/ iscsi Host High Capacity Guide 2U RAID Subsystem Connections ESDS S12FR2840N ESDS S12FR28404 ESDS S12FS2840N CH0 CH1 CH2 CH3 CH0 CH1 CH2 CH3 ESDS S12EG21404 CH0 CH1 CH2 CH3 s s Ctrl ESDS S12SR2240 ESDS S12FG28404 CH0 Statu Statu Ctrl ESDS S12SG22404 Statu Statu CBM ESDS S12SG2240 ESDS S12FG18424 CH0 CH0 CH0 CH1 CH0 CH1 CH1 CBM ESDS S12ER21404 ESDS S12FR18404 ESDS S12FG1440 CH0 CH2 Link 2 ESDS S12FR2850 CH1 CH3 s s Statu Statu CBM CH2 CH3 s s Ctrl CH1 ESDS S12FR1440 Statu Statu Ctrl Link 2 s s CH1 CBM s s CH1 Statu Statu Statu Link 2 CH0 s s Ctrl CBM CBM Ctrl CH0 CH1 Statu Statu s Statu Ctrl ESDS S12EG11402 s s CBM s Ctrl CH0 CH1 s s Ctrl CBM Link 2 Link 2 ESDS S12SR22404 Statu Statu Statu Statu CBM Link 2 Link 2 Link 2 ESDS S12FG

40 High Capacity Guide Fibre / SAS/ iscsi Host s Connections 4U+ESDS S16SJ2000R 4U + ESDS S16SJ1000R RAID System 4U + ESDS S16SJ2000S RAID System 4U + ESDS S16SJ1000S RAID System RAID System 3U+ ESDS S16SJ2000R RAID System 2U+ ESDS S12SJ2000R RAID System 3U+ESDS S16SJ1000R 3U+ESDS S16SJ2000S 3U+ESDS S16SJ1000S RAID System RAID System 2U+ESDS S12SJ2000S 2U+ESDS S12SJ1002R RAID System RAID System * modes: Up to 6 Systems for both R and G models. R model can be connected to expansion enclosures using faulttolerant links. * 170cm SAS external cable is recommended. 38 RAID System 2U+ESDS S12SJ1000G RAID System

41 High Capacity Guide Fibre / SAS/ iscsi Host s Connections 4U48bay+ ESDS S48SJ2000R 4U48bay+ ESDS S48SJ2000G RAID System RAID System * modes: Up to 6 Systems for both R and G models. * 170cm SAS external cable is recommended. R model can be connected to expansion enclosures using faulttolerant links. 39

42 High Capacity Guide ESDS B12FR/G ESDS B12FR28404 (1U, 12 Disks) ESDS B12FR28404 (1U, 12 Disks) ESDS B12FG28404 (1U, 12 Disks) " SAS Disk Based ESDS S16SJ2000S (Up to 6 units)(3u, 16 Disks) ESDS S12SJ2000R (Up to 6 units)(2u, 12 Disks) ESDS S12SJ2000G (Up to 6 units)(2u, 12 Disks) ESDS B12SJ2000R/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B12FR28404 ESDS B12SJ2000R (1U, 12 Disks) + (Up to 6 units)(1u, 12 Disks) = Up to 84 Disks ESDS B12FG28404 (1U, 12 Disks) ESDS B12FR28404 (1U, 12 Disks) ESDS B12SR2240 (1U, 12 Disks) ESDS B12SR2240 (1U, 12 Disks) ESDS B12SG2240 (1U, 12 Disks) ESDS B12SG2240 (1U, 12 Disks) ESDS B12SR2240 (1U, 12 Disks) ESDS B12SG2240 (1U, 12 Disks) + + ESDS B12SR/G ESDS B12SJ2000G (Up to 6 units)(1u, 12 Disks) ESDS S16SJ2000R (Up to 6 units)(3u, 16 Disks) = = = = = ESDS B12SJ2000R/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B12SJ2000R + (Up to 6 units)(1u, 12 Disks) = ESDS B12SJ2000R + (Up to 6 units)(1u, 12 Disks) = ESDS B12SJ2000G + (Up to 6 units)(1u, 12 Disks) = ESDS B12SR2240 ESDS S16SJ2000R (1U, 12 Disks) + = (Up to 6 units)(3u, 16 Disks) ESDS B12ER21404 (1U, 12 Disks) ESDS B12EG21404 (1U, 12 Disks) ESDS S16SJ2000S + (Up to 6 units)(3u, 16 Disks) = ESDS S12SJ2000R + (Up to 6 units)(2u, 12 Disks) = ESDS S12SJ2000G + = (Up to 6 units)(2u, 12 Disks) Up to 84 Disks Up to 108 Disks Up to 108 Disks Up to 84 Disks Up to 84 Disks Up to 84 Disks Up to 84 Disks Up to 84 Disks Up to 108 Disks Up to 108 Disks Up to 84 Disks Up to 84 Disks ESDS B12SJ2000R/G ESDS B12ER/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B12ER21404 ESDS S16SJ2000R (1U, 12 Disks) + (Up to 6 units)(3u, 16 Disks) = Up to 108 Disks ESDS B12EG21404 (1U, 12 Disks) + ESDS B12SJ2000R + = (Up to 6 units)(1u, 12 Disks) ESDS B12SJ2000G + = (Up to 6 units)(1u, 12 Disks) ESDS B12SG21404 ESDS S16SJ2000S = (1U, 12 Disks) + = (Up to 6 units)(3u, 16 Disks) ESDS B12ER21404 ESDS S12SJ2000R (1U, 12 Disks) + = (Up to 6 units)(2u, 12 Disks) ESDS S12SJ2000G = (Up to 6 units)(2u, 12 Disks) Up to 84 Disks Up to 84 Disks Up to 108 Disks Up to 84 Disks Up to 84 Disks Up to 7U Height Up to 7U Height Up to 19U Height Up to 19U Height Up to 13U Height Up to 13U Height Up to 7U Height Up to 7U Height Up to 7U Height Up to 19U Height Up to 19U Height Up to 13U Height Up to 13U Height Up to 7U Height Up to 7U Height Up to 19U Height Up to 19U Height Up to 13U Height Up to 13U Height RAID System Connections ESDS B12FR28404 Link2 ESDS B12FG28404 ESDS B12SR2240 Link 2 ESDS B12SG2240 Cables Accessories 9270CSFP4GA01: Agilent Fibre Channel 4.25/2.125 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9370CSFP8G: Avago Fibre Channel 8.5 / 4.25 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9270CFCCab01: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meter 9270CSASCab01:SAS external cable, 50 cm (SFF8470) 9270CSASCab02:SAS external cable, 120 cm (SFF8470) 2.5" Drive Fibre / SAS Host 9270CmSASCab1SAS external cable, 50 cm (SFF8088) 9270CmSASCab2SAS external cable, 120 cm (SFF8088) 9270CmSASCab3SAS external cable, 50 cm (SFF8470SFF8088) 9270CmSASCab4SAS external cable, 120 cm(sff8470sff8088) 9270CmSASCab5SAS external cable, 170 cm(sff8470 to SFF8088) 9270CmSASCab6SAS external cable, 170 cm(sff8088 to SFF8088) 9270CmSASCab7SAS external cable, pull type, 50 cm(sff8088 to SFF8088) 9270CmSASCab8SAS external cable, pull type, 120 cm(sff8088 to SFF8088) s Connections Redundantcontroller RAID Dualcontroller s Singlecontroller RAID A B 1st 2nd. Last Dualcontroller s 1st 2nd. Last Singlecontroller s IN put OUT put IN put OUT put * Up to 6 System for both R and G models. R model can be connected to expansion enclosures using faulttolerant links. * 170cm SAS external cable is recommended 40

43 High Capacity Guide 2.5" SAS Disk Based ESDS B24SJ2000R/S ESDS B24FR/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B24FR28404 ESDS B24SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) = Up to 144 Disks ESDS B24FG28404 ESDS B24SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) = Up to 144 Disks ESDS B24FR28404 ESDS S16SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) = Up to 104 Disks ESDS B24FG28404 ESDS S16SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) = Up to 104 Disks ESDS B24FR28404 ESDS S12SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 12 Disks) = Up to 84 Disks ESDS B24FG28404 ESDS S12SJ2000G + = Up to 84 Disks ( 2U, 24 Disks) ( Up to 5 units)(2u, 12 Disks) ESDS B24SJ2000R/S ESDS B24FR/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B24FR28426 ESDS B24SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) = Up to 144 Disks ESDS B24FG ESDS B24SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) = Up to 144 Disks ESDS B24FR ESDS S16SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) = Up to 104 Disks ESDS B24FG ESDS S16SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) = Up to 104 Disks ESDS B24FR ESDS S12SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 12 Disks) = Up to 84 Disks ESDS B24FG ESDS S12SJ2000G + = Up to 84 Disks ( 2U, 24 Disks) ( Up to 5 units)(2u, 12 Disks) ESDS B24SR/G ESDS B24SR2240 ( 2U, 24 Disks) ESDS B24SJ2000R/S ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B24SG2240 ESDS B24SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) ESDS B24SR2240 ESDS S16SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) ESDS B24SG2240 ESDS S16SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) ESDS B24SR2240 ESDS S12SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 12 Disks) ESDS B24SG2240 ESDS S12SJ2000G ( 2U, 24 Disks) + ( Up to 5 units)(2u, 12 Disks) ESDS B24ER21426 ESDS B24SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) ESDS B24EG21426 ESDS B24SJ2000S + ( 2U, 24 Disks) ( Up to 5 units)(2u, 24 Disks) = Up to 84 Disks = Up to 84 Disks ESDS B24ER21426 ESDS S16SJ2000R + ( 2U, 24 Disks) ( Up to 5 units)(3u, 16 Disks) = Up to 104 Disks Up to 17U Height ESDS B24EG21426 ESDS S16SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) ESDS B24ER21426 ESDS S12SJ2000R + ( 2U, 24 Disks) ( Up to 5 units)(2u, 12 Disks) ESDS B24EG21426 ESDS S12SJ2000G + ( 2U, 24 Disks) ( Up to 5 units)(2u, 12 Disks) = Up to 144 Disks Up to 12U Height = Up to 144 Disks Up to 12U Height = Up to 104 Disks Up to 17U Height = Up to 84 Disks = Up to 84 Disks Up to 12U Height Up to 12U Height Up to 17U Height Up to 17U Height Up to 12U Height Up to 12U Height ESDS B24SJ2000R + = Up to 144 Disks Up to 12U Height ( Up to 5 units)(2u, 24 Disks) ESDS B24SJ2000R/S ESDS B24ER/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B24SG22424 ESDS B24SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(2u, 24 Disks) ESDS B24SR22424 ESDS S16SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) ESDS B24SG22424 SDS S16SJ2000S ( 2U, 24 Disks) + ( Up to 5 units)(3u, 16 Disks) ESDS B24SR22424 ESDS S12SJ2000R ( 2U, 24 Disks) + ( Up to 5 units)(2u, 12 Disks) ESDS B24SG22424 ESDS S12SJ2000G ( 2U, 24 Disks) + ( Up to 5 units)(2u, 12 Disks) Up to 12U Height Up to 12U Height Up to 17U Height Up to 17U Height Up to 12U Height Up to 12U Height = Up to 144 Disks Up to 12U Height = Up to 104 Disks Up to 17U Height = Up to 104 Disks Up to 17U Height = Up to 84 Disks = Up to 84 Disks Up to 12U Height Up to 12U Height Up to 12U Height Up to 12U Height ESDS B24SJ2000R/S ESDS B24SR/G ESDS S12SJ2000R/G ESDS S16SJ2000R/S ESDS B24SR22424 ESDS B24SJ2000R + = Up to 144 Disks Up to 12U Height ( 2U, 24 Disks) ( Up to 5 units)(2u, 24 Disks) = Up to 144 Disks Up to 12U Height = Up to 104 Disks Up to 17U Height = Up to 104 Disks Up to 17U Height Up to 12U Height Up to 12U Height 2.5" Drive Fibre / SAS /iscsi Host RAID System Connections ESDS B24SR22424 Link 2 ESDS B24SG22424 ESDS B24FR28426 Link 2 ESDS B24FG28426 ESDS B24FR28404 Link 2 ESDS B24FG28404 ESDS B24SR2240 Link 2 ESDS B24SG2240 ESDS B24ER21426 Link 2 ESDS B24EG

44 Link Link Link Link Link Link SASIN SASIN SASIN SASIN SASIN SASIN Link Link Link Link Link Link SASOUT SASOUT SASOUT SASOUT SASOUT SASOUT Link Link Link SASIN SASIN SASIN Link Link Link SASOUT SASOUT SASOUT High Capacity Guide s Connections 2.5" Drive Fibre / SAS /iscsi Host Redundantcontroller RAID Dualcontroller s Singlecontroller RAID SASIN SASOUT 1st 1st SASIN SASOUT 2nd. Last 2nd. Last Cables Accessories 9270CSFP4GA01: Agilent Fibre Channel 4.25/2.125 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9370CSFP8G: Avago Fibre Channel 8.5 / 4.25 / GBd Small Form Pluggable Optical Transceiver, LC, wavelength 850nm, multimode 9270CFCCab01: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LCLC, MM62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meter 9270CSASCab01:SAS external cable, 50 cm (SFF8470) 9270CSASCab02:SAS external cable, 120 cm (SFF8470) 9270CmSASCab1SAS external cable, 50 cm (SFF8088) 9270CmSASCab2SAS external cable, 120 cm (SFF8088) 9270CmSASCab3SAS external cable, 50 cm (SFF8470SFF8088) 9270CmSASCab4SAS external cable, 120 cm(sff8470sff8088) 9270CmSASCab5SAS external cable, 170 cm(sff8470 to SFF8088) 9270CmSASCab6SAS external cable, 170 cm(sff8088 to SFF8088) 9270CmSASCab7SAS external cable, pull type, 50 cm(sff8088 to SFF8088) 9270CmSASCab8SAS external cable, pull type, 120 cm(sff8088 to SFF8088) * Up to 6 System for both R and G models. R model can be connected to expansion enclosures using faulttolerant links. * 170cm SAS external cable is recommended 42

45 Shipping Reference 1U/2U A Package Dimensions B C Shipping Weight with System*1 Shipping Weight with System and HDD System Dimensions D E F G*2 System Weight Net weight BTU & Amps Maximum Heat Dissipation (Estimated) Maximum Current at 230V AC (Estimated) Air Airflow Direction 1U ESDS FFR40316 ESDS FFS40316 ESDS B12SJ1000R ESDS B12SJ1000S ESDS B12FR28404 ESDS B12SR2240 ESDS B12ER21404 ESDS B12SJ2000R 210mm mm mm mm mm mm kg 39.68lbs 20.42kg 44.91lbs 20.7kg 45.63lbs 43.5mm kg 53.48lbs 22.99kg 50.68lbs 43.5mm mm mm mm mm mm mm kg 33.07lbs 13.36kg 29.41lbs 13.06kg 28.79lbs 850 (250W) BTU/Hour 1296 (380W) BTU/Hour 1296 (380W) BTU/Hour 1.08A 1.65A 1.65A Front to Rear Front to Rear Front to Rear ESDS B12FG28404 ESDS B12SG2240 ESDS B12EG21404 ESDS B12SJ2000G 18.5kg 40.79lbs 20.99kg 45.83lbs 10.96kg 24.16lbs 850 (250W) BTU/Hour 1.08A Front to Rear ESDS S04SG2240 ESDS S12SJ1002R ESDS S12SJ1000G 191mm mm mm mm mm mm kg 33.51lbs 23.6kg 52.03lbs 25.5kg 56.22lbs 19.2kg 42.33lbs 33.44kg 73.72lbs 35.34kg 77.91lbs 43.5mm mm mm mm mm mm mm mm mm kg 17.63lbs 514.3mm mm kg 34.61lbs 17.6kg 38.8lbs 680 (200W) BTU/Hour 1725 (530W) BTU/Hour 1381 (460W) BTU/Hour 0.86A 2.30A 1.75A Front to Rear Front to Rear Front to Rear ESDS S12SR22404 ESDS S12FR28404 ESDS S12FR2840N ESDS S12FR18404 ESDS S12FR1440 ESDS S12SR2240 ESDS S12ER21404 ESDS S12SJ2000R ESDS S12SJ2000RN ESDS S12FR mm mm mm kg 71.29lbs 31.2kg 68.78lbs 41.44kg 91.36lbs 43.2kg 95.24lbs 90mm mm mm mm mm mm kg 39.90lbs 15.26kg 33.64lbs 1813 (530W) BTU/Hour 2.30A Front to Rear 2U ESDS S12FG28404 ESDS S12FG18424 ESDS S12FG2840N ESDS S12FG1440 ESDS S12SG2240 ESDS S12SG22404 ESDS S12EG11402 ESDS S12EG2140 ESDS S12SJ2000G ESDS S12SJ2000SN 31.24kg 68.87lbs 42.54kg 93.78lbs 500mm mm kg 37.48lbs 1197 (350W) BTU/Hour 1.52A Front to Rear ESDS S12FG kg 64.99lbs 41.48kg 91.45lbs mm mm kg 31.44lbs ESDS B24SR22424 ESDS B24FR28426 ESDS B24FR28404 ESDS B24SR2240 ESDS B24ER21426 ESDS B24SJ2000R ESDS B24SG22424 ESDS B24FG28426 ESDS B24FG28404 ESDS B24SG2240 ESDS B24EG21426 ESDS B24SJ2000S 400mm mm mm kg 62.26lbs 26.68kg 68.82lbs 32.80kg 92.31lbs 31.24kg 68.87lbs 87mm mm mm mm kg 38.47lbs 16.05kg 35.38lbs 1813 (530W) BTU/Hour 2.30A Front to Rear *1. Shipping weight includes HDD, spare parts and accessories packages and outer carton weight. All weight information are estimated numbers. The actual weight may vary according to drives and configurations. *2. System width (deep) is from the back of chassis ear to the rearend protrudings (PSU handles). A Shipping Box D F System *3. Please allow 200mm (7.87inch) at the back and 50mm (1.97inch) in front of the subsystem for cabling and airflow C B E G 43

46 Shipping Reference 3U/4U Package Dimensions A B C Shipping System Dimensions Shipping Weight Weight with with System System D E F G*2 and HDD System Weight Net weight BTU & Amps Maximum Heat Dissipation (Estimated) Maximum Current at 230V AC (Estimated) Air Airflow Direction ESDS F16FR4840 ESDS F16FS mm mm mm kg 79.85lbs 49.82kg lbs 130mm mm mm mm kg 45.33lbs 1813(350W) BTU/Hour 2.30A Front to Rear ESDS F16FR40314 ESDS S16SJ1000R ESDS F16FS40314 ESDS S16SJ1000S 460mm mm mm kg 67.24lbs 29.5kg 65.04lbs 43.62kg 96.17lbs 42.62kg 93.96lbs 130mm mm mm mm kg 62.83lbs 27.5kg 60.63lbs 1807 (530W) BTU/Hour 2.29A Front to Rear 3U 4U ESDS S16SR22424 ESDS S16SR22404 ESDS S16FR28426 ESDS S16ER2240 ESDS S16FR28404 ESDS S16FR18404 ESDS S16FR1440 ESDS S16SR2240 ESDS S16ER21426 ESDS S16SJ2000R ESDS S16ER11404 ESDS S16FR2850 ESDS S16SG22404 ESDS S16FG28426 ESDS S16EG2240 ESDS S16FG28404 ESDS S16FG18404 ESDS S16FG1440 ESDS S16SG2240 ESDS S16EG11404 ESDS S16EG21426 ESDS S16SJ2000S ESDS S16FG2850 ESDS S24FR28404 ESDS S24FR18404 ESDS S24FR1440 ESDS S24FR2850 ESDS S24SG22404 ESDS S24FG28404 ESDS S24FG18404 ESDS S24FG1440 ESDS S24SG2240 ESDS S24EG21426 ESDS S24FR mm mm mm mm mm mm kg 83.42lbs 36.37kg 80.18lbs 36.74kg 81lbs 34.53kg 76.13lbs 45.62kg lbs 43.36kg 95.59lbs 44.52kg 98.15lbs 41.52kg 91.54lbs 53.84kg lbs 52.37kg lbs 50.34kg 111lbs 50.63kg 111.4lbs 66kg lbs 67.36kg lbs 64.92kg lbs 65.52kg lbs 130mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg 47.75lbs 20.8kg 45.86lbs 20.56kg 45.33lbs 18.96kg 41.80lbs 27.44kg 60.49lbs 25.7kg 56.66lbs 26.34kg 58.07lbs 23.86kg 52.6lbs 1807 (530W) BTU/Hour 1573 (460W) BTU/Hour 2.29A 2A Front to Rear Front to Rear Package Dimensions 1 A*4 A B C System Dimensions Shipping Shipping Weight Weight with with System System D E F G*2 and HDD System Weight Net weight BTU & Amps Maximum Heat Dissipation (Estimated) Maximum Current at 230V AC (Estimated) Air Airflow Direction 4U 48bay ESDS S48FR28426 ESDS S48FG28426 ESDS S48SJ2000R ESDS S48SJ2000G 426mm 16.78" 670mm 26.38" 1150mm 45.28" 630mm 24.80" 94.33kg lbs kg lbs 175.9mm 69.25" 445mm 15.1" 873.5mm 34.39" 939mm 36.97" 53.41kg lbs 1655 (530W) BTU/Hour 2.30A Front to Rear *1. Shipping weight includes HDD, spare parts and accessories packages and outer carton weight. All weight information are estimated numbers. The actual weight may vary according to drives and configurations. C B F System *2. System width (deep) is from the back of chassis ear to the rearend protrudings (PSU handles). *3. Please allow 200mm (7.87inch) at the back and 50mm (1.97inch) in front of the system for cabling and airflow. A Shipping Box D E G 44

47 Rackmount Kits P/N 9276CSlider CSlider CESlide CESlide CSlider CSlider36 Photos 1U ESDS FFR40316 ESDS FFS40316 ESDS B12FR28404 ESDS B12FG28404 ESDS B12SR2240 ESDS B12SG2240 ESDS B12ER21404 ESDS B12EG21404 ESDS B12SJ2000R ESDS B12SJ2000G ESDS B12SJ1000R ESDS B12SJ1000S ESDS S04SG2240 2U ESDS S12SJ1000G 3U ESDS F16FR40316 ESDS F16FS U Minimum Length (Poletopole) * mm (23.75 inches) 608mm (23.94 inches) 600mm/650 mm (23.62/25.59 inches) 593 mm/601mm (23.35/23.66 inches) Maximum Length (Poletopole) * mm (36.11 inches) mm (32.25 inches) 730mm/930 mm (28.74/36.61 inches) 824mm/907 mm (32.44/35.71 inches) Side View of Rack Cabin Top View of Rack Cabinet * 1. The "poletopole" length (or "posttopost" length) refers to the distance between the front screw hole pole (post) and the rear screw hole pole (post) in a rack cabin. A typical 900mm rack cabin often has poletopole length of around 670 mm, and 800mm rack has around 615 mm. Front Screw Pole Rear Screw Pole Poletopole Length 1U Rail Kit Rear Screw Pole Poletopole Length Subsystem Subsystem Slide Rail Kit Subsystem Brackets Front Screw Pole 45

48 Rackmount Kits P/N 9279CSlider CSlider36 9CCSlider CSlider36 Photos 1U ESDS S12SJ1000R 2U ESDS S12SR22404 ESDS S12SG22404 ESDS S12EG11402 ESDS S12SR2240 ESDS S12SG2240 ESDS S12FR28404 ESDS S12FG28404 ESDS S12FR2840N ESDS S12FS2840N ESDS S12FR18404 ESDS S12FG18424 ESDS S12FR1440 ESDS S12FG1440 ESDS S12SJ2000R ESDS S12SJ2000G ESDS S12SJ2000RN ESDS S12SJ2000GN ESDS S12FR2850 ESDS S12FG2850 ESDS B24SR22424 ESDS B24SG22424 ESDS B24FR28426 ESDS B24FG28426 ESDS B24FR28404 ESDS B24FG28404 ESDS B24SR2240 ESDS B24SG2240 ESDS B24ER21426 ESDS B24EG21426 ESDS B24SJ2000R ESDS B24SJ2000S 3U ESDS S16SR22424 ESDS S16SG22424 ESDS S16SR22404 ESDS S16SG22404 ESDS S16FR28426 ESDS S16FG28426 ESDS S16ER2240 ESDS S16EG2240 ESDS S16SR2240 ESDS S16SG2240 ESDS S16ER11404 ESDS S16EG11404 ESDS S16ER21426 ESDS S16EG21426 ESDS S16FR28404 ESDS S16FG28404 ESDS S16FR18404 ESDS S16FG18404 ESDS S16FR1440 ESDS S16FG1440 ESDS F16FR4840 ESDS F16FG4840 ESDS S16SJ2000R ESDS S16SJ2000G ESDS S16FR2850 ESDS S16FG2850 ESDS S48FR28426 ESDS S48FG28426 ESDS S48SJ2000R ESDS S48SJ2000G 4U ESDS S24SG22404 ESDS S24SG2240 ESDS S24EG21426 ESDS S24FR28404 ESDS S24FG28404 ESDS S24FR18404 ESDS S24FG18404 ESDS S24FR1440 ESDS S24FG1440 ESDS S24FR2850 ESDS S24FG2850 Minimum Length (Poletopole) *1 575 mm (22.64 inches) mm (24 inches) mm (24 inches) 762 mm (30 inches) Maximum Length (Poletopole) * mm (36.07 inches) mm (36 inches) mm (36 inches) mm (37 inches) Side View of Rack Cabin Top View of Rack Cabinet Front Screw Pole Rear Screw Pole Rear Screw Pole * 1. The "poletopole" length (or "posttopost" length) refers to the distance between the front screw hole pole (post) and the rear screw hole pole (post) in a rack cabin. A typical 900mm rack cabin often has poletopole length of around 670 mm, and 800mm rack has around 615 mm. Poletopole Length 1U Rail Kit Subsystem Subsystem Poletopole Length Slide Rail Kit Subsystem Brackets Front Screw Pole 46

49 PWR BUSY ATTEN Ready ESC ENT MUTE PWR BUSY ATTEN Ready ESC ENT MUTE PWR BUSY ATTEN Ready ESC ENT MUTE PWR BUSY ATTEN Ready ESC ENT MUTE SANWatch Storage Suite SANWatch, Infortrend's storage management suite, provides all functions necessary to discover, configure, administer, and monitor Infortrend's storage solutions. SANWatch enables you to easily manage your storage and access all data protection and highavailability features through one easytouse interface. SANWatch is a Javabased, crossplatform software management suite that provides support for many mainstream operating systems. SANWatch features SSL (Secure Socket Layer) link protection and rolebased accesslevels for management carried out on different installation sites and for different purposes. SANWatch Offers Centralized for DirectAttached Storage (DAS) or Storage Area Network (SAN) Center , LAN broadcast Fax SMS, MSN, SNMP Data Host Agent Data Host Agent Data Host Agent Data Host Agent Data Host Agent Available on All Infortrend Storage Systems SANWatch is available on all products in the ESVA, EonStor DS and EonStor product families. SANWatch is a uniform software suite with specific customized utilities to meet features of each product family. For ESVA systems, SANWatch includes a Virtualization Manager to manage the virtualization functions found on ESVA systems. SANWatch is shipped together with storage systems. Userfriendly Graphical User Interface SANWatch features a userfriendly graphical user interface (GUI) that provides a clear view of storage system information and functions. Information is grouped in easytounderstand graphics and tables. Configuration and management functions can be accessed with a few simple clicks of the mouse. Easy Access to All Storage Systemrelated Information SANWatch provides easy access to all relevant information of your storage system, including: Overall system operation status. Status of all hardware components as well as cache size, firmware version, CPU and board temperature, voltage etc. Tasks processed by the system, including task descriptions and their progress. Details of all logical drives/volumes in the system. Read/write performance (MB/s) of each system controller. Status and performance of each disk drive in the system. Other Features SANWatch connection via inband or outofband methodology. Centralized management of multiple arrays locally or remotely over LAN/WAN. Collection of events from multiple systems to an administrator. Event severity, type, and order filtering. Agentbased hierarchy for onetomany management. Automatically detects systems within a network. Export and restore system configuration profiles. Licenses for additional software packages are separately purchased and activated. Benefits 1 SANWatch shipped standard with storage systems ; no additional fees. Storage systems and SANWatch developed by the same team of storage experts, ensuring optimal synergy between storage hardware and software. Clear and easytonavigate graphical interface for better storage planning and utilization. Centralized structure simplifies management, saves time and reduces errors. Early warning of potential problems ensures consistently high performance. Automatically displays and sends notification of critical status changes and events for proactive administration. Access to and configuration of data service features helps to increase storage performance and protect missioncritical data. 47 Notifications Keep You UptoDate of Critical System Events SANWatch features a Notification Manager, allowing users to choose how and when they are notified of system events. Notifications can be transmitted to IT managers through a variety of methods, including , LAN broadcast, fax, SNMP traps, SMS, and MSN. Users can select more than one method through which they wish to be notified of events. Every datacenter is different. A system event that is critical for one datacenter might be less important for another. With SANWatch, users can select event severity levels for which they want to be notified, ensuring that you are only notified of system events that are important to you and your enterprise Manage EonPath and Data Service Features SANWatch enables users to manage Infortrend s multipathing software, EonPath. EonPath ensures continuous data flow through automatic failover and failback in the event of data path failure and dynamically distributes workloads among all available data paths to optimize productivity. All relevant settings and configurations for EonPath can be completed with SANWatch. On EonStor DS and ESVA systems, data service features, such as snapshot, volume copy/mirror and remote replication, are available. These features help protect your data and are critical elements of disaster recovery plans. With SANWatch users can manage all relevant processes for data service features. 1 2 SANWatch Operating System Compatibility Windows Server 2003 R2 SP2 (32/64) Windows Server 2008 SP1 Enterprise / SP1 Enterprise cluster (32/64) Windows Server 2008 SP2 Enterprise / Enterprise cluster (32) Windows Server 2008 R2 / R2 cluster (64) Windows Vista Ultimate Windows 7 Linux RHEL 6.1 (32/64) Linux SUSE Enterprise Server 10 SP2 (32/64) Sun (Sparc) Solaris 10 Apple Mac OS X IBM AIX HPUX 11i v3 SANWatch available on ESVA, EonStor DS and EonStor systems. For detailed compatibility details, please contact our sales representatives. SANWatch requires Java Runtime Environment (JRE) 1.6. Compatible with SANWatch version 2.1J or later.

50 Warranty and Quality Optional Extended Warranty In addition to the threeyear Regular Warranty, Infortrend offers an Optional Extended Warranty (battery excluded) that extends the warranty period for the product an additional two years. Customers may purchase the Optional Extended Warranty at the time of sale or within the Regular Warranty period. For more detailed information, please contact your local representatives. Quality System Infortrend is an ISO9001:2000 and ISO14001:2004 certified manufacturer known forits high quality standards. Our finished goods adhere to international standards including RoHS, Milstd105E, Milstd810F, IEC 60950, and IEC We have also passed prevalent company and product certifications, such as UL, CE, CB, BSMI, and FCC. Sound quality assurance is achieved through the following measures: Fully implemented TQM (Total Quality Methodology) and an automated shop floor control system Serialnumberbased product traceability from subsystems, modules, all the way down to the component level Inhouse RoHScompliance inspection starting from system design and SCM (Supply Chain ) through mass production Prepilot design verification and NPI (New Product Introduction) gate control procedures 100% burnin and aging testing for quality control of mass production Continual improvement in response to customer feedback Our products are fully tested at all stages of manufacturing to verify they are stable and problemfree. All RAID systems come with a standard threeyear warranty. As an option, customers may purchase a twoyear extension to enjoy fiveyear worryfree warranty protection for their RAID systems. 48

51 Alliance Partners Alliance Partners Infortrend works closely with industry leaders to deliver integrated storage solutions. Thanks to extensive compatibility testing, certification, and collaborative product design, Infortrend can assure that our systems are fully interoperable with partner solutions. Microsoft As a Microsoft Gold Partner and Microsoft Virtualization Partner, Infortrend provides optimized storage solutions for Microsoft environments. Almost all Infortrend products are Microsoft WHQL certified and listed on the Windows website, affirming that our storage solutions meet the requirements specified by Microsoft for interoperability with Windows servers. VMware Infortrend is a VMware Elitelevel Technology Alliance Partner (TAP). Infortrend storage systems are VMware certified to ensure that our customers can benefit from high storage utilization and simplified infrastructure with industryleading solutions and virtualization technologies. Oracle Oracle databases are critical to many businesses. As an Oracle Partner Network member, Infortrend has a collaborative alliance with Oracle that leverages leadership in enterpriseclass storage solutions, database and applications to help customers manage storage easily and efficiently. Citrix Infortrend is a Citrix Ready partner. Infortrend storage systems have been verified as Citrix Ready and can be trusted to work effectively with Citrix products, including Citrix XenServer and Citrix XenDesktop, in order to optimize performance of virtualized datacenters. Milestone Infortrend is a Milestone Solution Partner (MSP). Infortrend storage systems are compatible with Milestone software, and customers can use Infortrend systems in video surveillance applications featuring Milestone solutions. 49

52 Infortrend Technology, Inc. All rights reserved. Any information provided herein is without warranties of any kind of and is subject to change without prior notice. Infortrend, EonStor, SANWatch and EonPath are registered trademarks of Infortrend Technology, Inc. Infortrend logo and ESVA are trademarks of Infortrend Technology, Inc. All other names, brands, or services are trademarks or registered trademarks of their respective owners. Americas (San Jose, USA) Infortrend Corporation EMEA (Basingstoke, UK) Infortrend Europe Ltd. China (Beijing) Infortrend Technology, Ltd. Tel: Tel: Tel: Asia Pacific (Taipei, Taiwan) Infortrend Technology, Inc. Tel: US East Coast Office Tel: Germany (Munich) Infortrend Deutschland GmbH Tel: +49 (0)89 / sales.de@infortrend.com Japan ( 日本, 東京 ) Infortrend Japan, Inc. Tel: sales.jp@infortrend.com Product quick reference guide_2012 v1.2

EonStor DS. Affordable and flexible storage solutions with enterprise-class data protection. Product Quick Reference Guide

EonStor DS. Affordable and flexible storage solutions with enterprise-class data protection. Product Quick Reference Guide EonStor DS Affordable and flexible torage olution with enterpriecla data protection Product Quick Reference Guide 011 EonStor DS Data Service EonStor DS i deigned to upport critical application for mall

More information

EonStor DS - SAS Series High-Availability Solutions Delivering Excellent Storage Performance

EonStor DS - SAS Series High-Availability Solutions Delivering Excellent Storage Performance EonStor DS EonStor DS - SAS Series High-Availability Solutions Delivering Excellent Storage Performance Reliability and Availability and volume copy/ mirror functionality enables quick data recovery after

More information

EonStor DS - iscsi Series High-Availability Solutions Delivering Excellent Storage Performance

EonStor DS - iscsi Series High-Availability Solutions Delivering Excellent Storage Performance EonStor DS EonStor DS - iscsi Series High-Availability Solutions Delivering Excellent Storage Performance Reliability and Availability Local and remote replication functionality enables quick data recovery

More information

EonStor DS 3000 Series Product Quick Reference Guide

EonStor DS 3000 Series Product Quick Reference Guide EonStor DS 3000 Series Product Quick Reference Guide Company Profile Since its founding in 1993, Infortrend has distributors, and technology partners. We free to get in touch with us Infortrend is been

More information

Highlights. EonStor DS.

Highlights. EonStor DS. www.infortrend.com EonStor DS EonStor DS - iscsi Series Highlights and Availability Local and remote replication functionality enables quick data recovery after logical errors and physical errors Redundant

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000T Gen Up to 1.M IOPS and,00 MBps throughput High IOPS solutions ideal for database

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High Speed Flexible Storage Delivers Robust Reliability and Fast performance Ÿ Up to.m IOPS and,00 Mbps throughput Ÿ High IOPS ideal for database and VDI applications, while bandwidth

More information

Infortrend ESVA PRODUCT QUICK REFERENCE GUIDE. esva.infortrend.com

Infortrend ESVA PRODUCT QUICK REFERENCE GUIDE. esva.infortrend.com Infortrend ESVA PRODUCT QUICK REFERENCE GUIDE The Infortrend ESVA (Enterprise Scalable Virtualized Architecture) Series is a leading storage solution designed for mid-range enterprise SAN. At affordable

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000T Gen Up to 1.M IOPS and,00 MBps throughput High IOPS solutions ideal for database

More information

EonStor Subsystem Specification Matrix

EonStor Subsystem Specification Matrix EonStor Subsystem Specification Matrix Fibre to Fibre RAID Subsystem Fibre RAID Head FF-R4031-6 FF-S4031-6 FF-R4030-6 FF-S4030-6 upgradeable to redundant upgradeable to redundant 2 () 2 () 2 () + 4 ()

More information

EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability

EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability Available models EonStor DS 1036RTB EonStor DS 102RB/RTB Small form factor: space-saving design

More information

Storageflex HA3969 High-Density Storage: Key Design Features and Hybrid Connectivity Benefits. White Paper

Storageflex HA3969 High-Density Storage: Key Design Features and Hybrid Connectivity Benefits. White Paper Storageflex HA3969 High-Density Storage: Key Design Features and Hybrid Connectivity Benefits White Paper Abstract This white paper introduces the key design features and hybrid FC/iSCSI connectivity benefits

More information

Infortrend EonStor DS series. Product Matrix 2015

Infortrend EonStor DS series. Product Matrix 2015 Infortrend EonStor DS series Product Matrix 205 System Overview The EonStor DS family offers a wide range of models featuring diverse host- and drive-side connectivity types and form factors. Host connectivity

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000U Up to 1M IOPS(All cache hit) and 0K IOPS(End to end) and 6,00 MBps read throughput

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000U Up to 0K read IOPS and 6,00 MBps read throughput High IOPS solutions ideal for

More information

EonStor DS 4000 series

EonStor DS 4000 series EonStor DS 4000 series High-powered performance featuring 2Gb/s SAS for midrange storage market Latest SAS 3.0 technology for expandability and performance 2Gb/s SAS interface on client and drive sides

More information

EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability

EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability EonStor DS 1036RTB EonStor DS 102RB/RTB Small form factor: space-saving design and high density

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000T Gen Up to 1.M read IOPS and,00 MBps read throughput High IOPS solutions ideal

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

IT Systems / Enterprise Storage Solutions EonStor A24F R2224

IT Systems / Enterprise Storage Solutions EonStor A24F R2224 IT Systems / Enterprise Storage Solutions EonStor A24F R2224 page 1 / 6 EonStor A24F-R2224 * Market leading I/O performance -Sustained RAID5 Read/Write : 770/460 (MB/sec) * Ultra-high-density, 4U-profile,

More information

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment. The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment. IPMI Control Dual Power Supplies Enhanced Metadata Uptime Storage Up to 1.3M IOPS and 5,500 MBps throughput

More information

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Application notes Abstract These application notes explain configuration details for using Infortrend EonStor DS Series iscsi-host

More information

Using ESVA to Optimize Returns on Investment

Using ESVA to Optimize Returns on Investment Using ESVA to Optimize Returns on Investment White paper Abstract This white paper explains how ESVA helps users optimize returns of achievement by achieving maximized capacity utilization, fully-utilized

More information

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Ultra high,000mb/s read and 5,500MB/s write stable throughput handle even the

More information

EonNAS 3000 series Powerful NAS / Unified Storage System

EonNAS 3000 series Powerful NAS / Unified Storage System EonNAS 000 series Powerful NAS / Unified Storage System Ÿ Active/active redundant - controller design for failover & high availability Ÿ Supports Global Namespace for streamlining storage management Uninterruptable

More information

EonStor DS 4000 Gen2 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 Gen2 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 Gen series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Gen Ultra high,000mb/s read and 5,500MB/s write stable throughput handle even

More information

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Gen Up to.5m IOPS, ideal choice for heavy workload applications such as database

More information

Genesis HyperMDC 200D

Genesis HyperMDC 200D The Genesis HyperMDC 200D is a metadata cluster designed for ease-of-use and quick deployment. IPMI Control Dual Power Supplies Enhanced Metadata Uptime Storage Up to 1.3M IOPS and 5,500 MBps throughput

More information

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Gen Ultra high,000mb/s read and 5,500MB/s write stable throughput handle even

More information

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Gen Ultra high,000mb/s read and 5,500MB/s write stable throughput handle even

More information

EonStor DS 4000 Gen2 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 Gen2 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 Gen series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Gen Ultra high,000mb/s read and 5,500MB/s write stable throughput handle even

More information

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System The all-in-one storage system for SMBs or subsidiaries ETERNUS DX - Business-centric Storage ETERNUS DX200 S3 Combining leading performance architecture

More information

DELL POWERVAULT MD FAMILY MODULAR STORAGE THE DELL POWERVAULT MD STORAGE FAMILY

DELL POWERVAULT MD FAMILY MODULAR STORAGE THE DELL POWERVAULT MD STORAGE FAMILY DELL MD FAMILY MODULAR STORAGE THE DELL MD STORAGE FAMILY Simplifying IT The Dell PowerVault MD family can simplify IT by optimizing your data storage architecture and ensuring the availability of your

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage IBM System Storage DS5020 Express Highlights Next-generation 8 Gbps FC Trusted storage that protects interfaces enable infrastructure

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (FC/iSCSI) enables SAN tiering Balanced performance well-suited for

More information

HPE MSA 2042 Storage. Data sheet

HPE MSA 2042 Storage. Data sheet HPE MSA 2042 Storage HPE MSA 2042 Storage offers an entry storage platform with built-in hybrid flash for application acceleration and high performance. It is ideal for performance-hungry applications

More information

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family Modular Storage The Dell PowerVault MD Storage Family The affordable choice The Dell PowerVault MD family is an affordable choice for reliable storage. The new MD3 models improve connectivity and performance

More information

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System The all-in-one storage system for SMBs or subsidiaries ETERNUS DX - Business-centric Storage

More information

HP P6000 Enterprise Virtual Array

HP P6000 Enterprise Virtual Array HP P6000 Enterprise Virtual Array The HP P6000 Enterprise Virtual Array (P6000 EVA) is an enterprise class virtual storage array family for midsized organizations at an affordable price. With built in

More information

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable MASS STORAGE AT ITS BEST The ARTEC VSTOR Vault VS Mass Storage Product Family ARTEC s

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

IBM System Storage DS6800

IBM System Storage DS6800 Enterprise-class storage in a small, scalable package IBM System Storage DS6800 Highlights Designed to deliver Designed to provide over enterprise-class functionality, 1600 MBps performance for with open

More information

Acer Hitachi AMS2300 specifications

Acer Hitachi AMS2300 specifications Product overview For mid-sized and larger businesses, Acer Hitachi Adaptable Modular Storage 2300 is an easy-to-use, scalable, cost-effective storage system for Microsoft Exchange Server, VMware, databases

More information

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family Dell PowerVault MD Family Modular storage The Dell PowerVault MD storage family Dell PowerVault MD Family The affordable choice The Dell PowerVault MD family is an affordable choice for reliable storage.

More information

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System The all-in-one storage system for SMBs or subsidiaries ETERNUS DX - Business-centric Storage

More information

Virtualization with Protection for SMBs Using the ReadyDATA 5200

Virtualization with Protection for SMBs Using the ReadyDATA 5200 Virtualization with Protection for SMBs Using the ReadyDATA WHITE PAPER For most small-to-medium size businesses, building a virtualization solution that provides scalability, reliability, and data protection

More information

IT Systems / Enterprise Storage Solutions EonStor A16U G2421

IT Systems / Enterprise Storage Solutions EonStor A16U G2421 IT Systems / Enterprise Storage Solutions EonStor A16U G2421 page 1 / 8 EonStor A16U-G2421 * Market leading I/O performance o Sustained RAID5 Read/Write: 515/365 (MB/sec) * Ultra-high-density, 3U-profile,

More information

IBM System Storage DS4800

IBM System Storage DS4800 Scalable, high-performance storage for on demand computing environments IBM System Storage DS4800 Highlights 4 Gbps Fibre Channel interface Includes IBM System Storage technology DS4000 Storage Manager

More information

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps:// IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com Exam : 000-115 Title : Storage Sales V2 Version : Demo 1 / 5 1.The IBM TS7680 ProtecTIER Deduplication Gateway

More information

Exam : Title : Storage Sales V2. Version : Demo

Exam : Title : Storage Sales V2. Version : Demo Exam : 000-115 Title : Storage Sales V2 Version : Demo 1.The IBM TS7680 ProtecTIER Deduplication Gateway for System z solution is designed to provide all of the following EXCEPT: A. ESCON attach to System

More information

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System Leading storage performance, automated quality of service ETERNUS DX - Business-centric Storage ETERNUS DX500 S3 Combining leading performance architecture

More information

High Performance NVR Appliance and Storage Solutions for Video Surveillance

High Performance NVR Appliance and Storage Solutions for Video Surveillance Vess A2000 & Vess R2000 Series High Performance NVR Appliance and Storage Solutions for Video Surveillance The latest advances in video surveillance are helping a growing number of organizations and corporations

More information

Empowering. Video Surveillance. Highly integrated. Simple to deploy. Vess A-Series & Vess R-Series

Empowering. Video Surveillance. Highly integrated. Simple to deploy. Vess A-Series & Vess R-Series Empowering Video Surveillance Highly integrated. Simple to deploy. Vess A-Series & Vess R-Series High Performance NVR Appliance and Storage Solutions for Video Surveillance The latest advances in video

More information

The IBM Storwize V3700: Meeting the Big Data Storage Needs of SMBs

The IBM Storwize V3700: Meeting the Big Data Storage Needs of SMBs IBM Software Analyst Brief White Paper December 2012 The IBM Storwize V3700: Meeting the Big Data Storage Needs of SMBs 2 The IBM Storwize V3700: Meeting the Big Data Storage Needs of SMBs Introduction

More information

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market

EonStor DS 4000 series High-powered performance featuring 12Gb/s SAS for midrange storage market EonStor DS 4000 series High-powered performance featuring Gb/s SAS for midrange storage market Ultra performance - DS 4000 Gen Ultra high,000mb/s read and 5,500MB/s write stable throughput handle even

More information

IBM System Storage DCS3700

IBM System Storage DCS3700 IBM System Storage DCS3700 Maximize performance, scalability and storage density at an affordable price Highlights Gain fast, highly dense storage capabilities at an affordable price Deliver simplified

More information

Data Sheet FUJITSU Storage ETERNUS DX60 S3 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS DX60 S3 Disk Storage System Data Sheet FUJITSU Storage ETERNUS DX60 S3 Disk Storage System Data Sheet FUJITSU Storage ETERNUS DX60 S3 Disk Storage System The Economy Storage System for SMBs ETERNUS DX - Business-centric Storage Combining

More information

White Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft

White Paper. A System for  Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS STORAGE CENTER DATASHEET STORAGE CENTER TECHNICAL SPECIFICATIONS Storage Center goes beyond the boundaries of traditional storage systems by combining modular standards-based hardware

More information

IBM System Storage N3000 Express series Modular Disk Storage Systems

IBM System Storage N3000 Express series Modular Disk Storage Systems Advanced system designed to enable outstanding, cost-effective deployment versatility IBM System Storage N3000 Express series Modular Disk Storage Systems Highlights High availability Takes Simple replication

More information

Hitachi Adaptable Modular Storage and Hitachi Workgroup Modular Storage

Hitachi Adaptable Modular Storage and Hitachi Workgroup Modular Storage O V E R V I E W Hitachi Adaptable Modular Storage and Hitachi Workgroup Modular Storage Modular Hitachi Storage Delivers Enterprise-level Benefits Hitachi Adaptable Modular Storage and Hitachi Workgroup

More information

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. 1 This training module is divided in six main chapters.

More information

EonNAS 3000 Gen2 series

EonNAS 3000 Gen2 series EonNAS 000 Gen series Powerful NAS / unified storage system Ÿ Active/active redundant - controller design for failover and high availability Consolidate file (CIFS/SMB, NFS, AFP, FTP) and block (iscsi,

More information

EonNAS 3012 Series Redundant NAS / Unified Storage System

EonNAS 3012 Series Redundant NAS / Unified Storage System EonNAS 30 Series Redundant NAS / Unified Storage System Ÿ Redundant -controller design with automatic failover & high availability Ÿ Supports Global Namespace for streamlining storage management Ÿ Advanced

More information

Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System Leading storage performance, automated quality of service ETERNUS DX - Business-centric Storage

More information

Data Sheet FUJITSU ETERNUS DX60 S3 Disk Storage System

Data Sheet FUJITSU ETERNUS DX60 S3 Disk Storage System Data Sheet FUJITSU ETERNUS DX60 S3 Disk Storage System Data Sheet FUJITSU ETERNUS DX60 S3 Disk Storage System The Economy Storage System for SMBs ETERNUS DX Storage Combining leading performance architecture

More information

Storage management is at the center

Storage management is at the center Special section: equallogic iscsi Peer storage Inside the EqualLogic PS Series iscsi Storage Arrays By John Joseph Eric Schott Kevin Wittmer Built on a patented peer storage architecture, the EqualLogic

More information

Data Sheet FUJITSU Storage ETERNUS DX8700 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX8700 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX8700 S3 Disk System Data Sheet FUJITSU Storage ETERNUS DX8700 S3 Disk System Enterprise Storage with leading scalability in capacity and performance ETERNUS DX - Business-centric

More information

Data Sheet FUJITSU Storage ETERNUS DX60 S4 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS DX60 S4 Disk Storage System Data Sheet FUJITSU Storage ETERNUS DX60 S4 Disk Storage System Data Sheet FUJITSU Storage ETERNUS DX60 S4 Disk Storage System The Economy Storage System for SMBs ETERNUS DX - Business-centric Storage FUJITSU

More information

IBM Storwize V7000 Unified

IBM Storwize V7000 Unified IBM Storwize V7000 Unified Pavel Müller IBM Systems and Technology Group Storwize V7000 Position Enterprise Block DS8000 For clients requiring: Advanced disaster recovery with 3-way mirroring and System

More information

Surveon NVR Series Overview

Surveon NVR Series Overview Surveon NVR Series Overview Content Surveon NVR Product Segment NVR/SMR Product Line Map Surveon NVR Introduction Product Advantages Appendix: Technical Information 2 Product Segment 3 16Bay NVR/SMR Product

More information

Midsize Enterprise Solutions Selling Guide. Sell NetApp s midsize enterprise solutions and take your business and your customers further, faster

Midsize Enterprise Solutions Selling Guide. Sell NetApp s midsize enterprise solutions and take your business and your customers further, faster Midsize Enterprise Solutions Selling Guide Sell NetApp s midsize enterprise solutions and take your business and your customers further, faster Many of your midsize customers might have tried to reduce

More information

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.0 This paper describes how to implement a Fibre Channel (FC) SAN

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide June 2017 215-11208_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

HP ProLiant ML370 G4 Storage Server

HP ProLiant ML370 G4 Storage Server HP ProLiant ML370 G4 Storage Server Data sheet The HP ProLiant ML370 Storage Server is ideal for price conscious small to medium business (SMB) or remote offices that need more performance and scalability

More information

Fully optimized for the applications that power your business. Why EonNAS Diverse form factor choices. Bigger and easier scalability

Fully optimized for the applications that power your business. Why EonNAS Diverse form factor choices. Bigger and easier scalability EonNAS 000 Series Fully optimized for the applications that power your business Why EonNAS 000 Infortrend s EonNAS 000 Series offers rackmount NAS solutions designed to help SMBs users optimize file sharing,

More information

Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array

Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array Superior performance at reasonable cost ETERNUS DX - Business-centric Storage ETERNUS

More information

IBM Storwize V5000 disk system

IBM Storwize V5000 disk system IBM Storwize V5000 disk system Latest addition to IBM Storwize family delivers outstanding benefits with greater flexibility Highlights Simplify management with industryleading graphical user interface

More information

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System Data Sheet FUJITSU Storage Disk System Data Sheet FUJITSU Storage Disk System Leading storage performance, automated quality of service ETERNUS DX - Business-centric Storage Combining leading performance

More information

NetApp FAS8000 Series

NetApp FAS8000 Series Datasheet NetApp FAS8000 Series Respond more quickly to changing IT needs with unified scale-out storage and industry-leading data management KEY BENEFITS Support More Workloads Run SAN and NAS workloads

More information

XS1200 Series. Product Highlights

XS1200 Series. Product Highlights Data Storage, Security & Performance XS1200 Series QSAN XS1200 Series is the most cost-effective SAN storage systems for SMB market. It is a perfect solution to the applications of surveillance, backup

More information

Hitachi Adaptable Modular Storage and Workgroup Modular Storage

Hitachi Adaptable Modular Storage and Workgroup Modular Storage O V E R V I E W Hitachi Adaptable Modular Storage and Workgroup Modular Storage Modular Hitachi Storage Delivers Enterprise-level Benefits Hitachi Data Systems Hitachi Adaptable Modular Storage and Workgroup

More information

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Lot # 10 - Servers. 1. Rack Server. Rack Server Server 1. Rack Server Rack Server Server Processor: 1 x Intel Xeon E5 2620v3 (2.4GHz/6 core/15mb/85w) Processor Kit. Upgradable to 2 CPU Chipset: Intel C610 Series Chipset. Intel E5 2600v3 Processor Family. Memory:

More information

DX-2104 / 2112 series NAS Affordable, Simple, and Reliable Enterprise-class NAS

DX-2104 / 2112 series NAS Affordable, Simple, and Reliable Enterprise-class NAS DX-2104 / 2112 series NAS Affordable, Simple, and Reliable Enterprise-class NAS Dax DX2104/ 2112 NAS series aims to bring the enterprise-class features into SMB market at competitive price, helps organizations

More information

What is QES 2.1? Agenda. Supported Model. Live demo

What is QES 2.1? Agenda. Supported Model. Live demo What is QES 2.1? Agenda Supported Model Live demo QES-Based Unified Storage Windows Server Block File iscsi CIFS NFS QES 2.1 One Architecture & Three Configurations SSD SSD Spinning Disk Hybrid All Flash

More information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Overview The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only

More information

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System The Flexible Data Safe for Dynamic Infrastructures. ETERNUS DX S2 DISK STORAGE SYSTEMS Fujitsu s second generation of ETERNUS DX disk storage systems,

More information

Considering the 2.5-inch SSD-based RAID Solution:

Considering the 2.5-inch SSD-based RAID Solution: Considering the 2.5-inch SSD-based RAID Solution: Using Infortrend EonStor B12 Series with Intel SSD in a Microsoft SQL Server Environment Application Note Abstract This application note discusses the

More information

Expanding Pool Capacity. FlashNAS ZFS

Expanding Pool Capacity. FlashNAS ZFS Expanding Pool Capacity in FlashNAS ZFS Table of Contents Product Models Covered by This Document... 3 FlashNAS Family of Unified Storage Systems... 4 Expanding the Capacity of a Storage Pool... 5 Step

More information

STOR-LX. Features. Linux-Based Unified Storage Appliance

STOR-LX. Features. Linux-Based Unified Storage Appliance STOR-LX DakotaStor-LX is a Linux-based unified storage appliance that delivers NAS and SAN (iscsi and Fibre Channel) functionality in a single box. Just attach it to your network and within minutes provide

More information

XS5200 Series. Product Highlights

XS5200 Series. Product Highlights Data Storage, Security & Performance XS5200 Series QSAN XS5200 Series is the high performance, simple, secure, scalable and affordable SAN storage systems for enterprise. It is an ideal solution to the

More information

Overview. Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance. August By Tom Hanvey; update by Peter Brouwer

Overview. Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance. August By Tom Hanvey; update by Peter Brouwer Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance August 2012 By Tom Hanvey; update by Peter Brouwer This paper describes how to implement a Fibre Channel (FC) SAN boot solution

More information

LEVERAGING A PERSISTENT HARDWARE ARCHITECTURE

LEVERAGING A PERSISTENT HARDWARE ARCHITECTURE WHITE PAPER I JUNE 2010 LEVERAGING A PERSISTENT HARDWARE ARCHITECTURE How an Open, Modular Storage Platform Gives Enterprises the Agility to Scale On Demand and Adapt to Constant Change. LEVERAGING A PERSISTENT

More information

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo Exam : S10-200 Title : Snia Storage Network Management/Administration Version : Demo 1. A SAN architect is asked to implement an infrastructure for a production and a test environment using Fibre Channel

More information

Dot Hill Product Evolution

Dot Hill Product Evolution , DotHill Dot Hill Product Evolution 2008 2009 2010 2000 Neptune 2130 2330 2530 5000 Krypton 2730 / 2730T 5730 2xx2 Mercury 2122 added 2322 / 2332 2522 / 2532 2722 / 2732 3000 Titanium 3120 / 3130 3320

More information

Backup Solutions with (DSS) July 2009

Backup Solutions with (DSS) July 2009 Solutions with Open-E Data Storage Software (DSS) July 2009 Different s opportunities using Open-E DSS The storage market is still growing rapidly with the fast growth in the SMB market segment. There

More information

FOUR WAYS TO LOWER THE COST OF REPLICATION

FOUR WAYS TO LOWER THE COST OF REPLICATION WHITE PAPER I JANUARY 2010 FOUR WAYS TO LOWER THE COST OF REPLICATION How an Ultra-Efficient, Virtualized Storage Platform Brings Disaster Recovery within Reach for Any Organization FOUR WAYS TO LOWER

More information

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired Overview The Smart Array 642 Controller (SA-642) is a 64-bit, 133-MHz PCI-X, dual channel, SCSI array controller for entry-level hardwarebased fault tolerance. Utilizing both SCSI channels of the SA-642

More information

ETERNUS DX60 and DX80

ETERNUS DX60 and DX80 Highlights Low environmental impact Highly scalable & versatile connectivity User friendly management systems Outstanding reliability 1 Overview (1) are designed to meet the needs of all environments from

More information