Servopress Kit YJKP. Instructions. Components Interfaces Installation Commissioning [ ]

Size: px
Start display at page:

Download "Servopress Kit YJKP. Instructions. Components Interfaces Installation Commissioning [ ]"

Transcription

1 Servopress Kit YJKP Instructions Components Interfaces Installation Commissioning [ ]

2 YJKP Translation of the original instructions YJKP-EN CANopen, Chrome, CiA, Ethernet/IP, Firefox, Internet Explorer, Modbus TCP, TCP/IP are registered trademarks of the respective trademark owners in certain countries. Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can lead to death or serious injuries Warning Hazards that can cause death or serious injuries Caution Hazards that can cause minor injuries Other symbols: Note Material damage or loss of function Recommendations, tips, references to other documentation Essential or useful accessories Information on environmentally sound usage Text designations: Activities that may be carried out in any order 1. Activities that should be carried out in the order stated General lists Result of an action/references to more detailed information 2 Festo YJKP-EN 1606 English

3 YJKP Table of Contents YJKP 1 Requirements for product use Target group Intended use Foreseeable misuse Applicable documents Range of applications and certifications Service Transport and storage Restraints in the packaging Product overview Servopress Kit Controller CECC-X-M1-YJKP Motor controller CMMP-AS Connecting cables Mounting Preparation Installation space Mounting surface Transport locks Installation Mounting of force sensor Installation Safety instructions Electrical installation CECC-X-M1-YJKP Power supply [X1] for device, digital and analogue inputs Power supply [X5] for digital outputs I/O interface [X2, X3, X4] Ethernet interface [X8] USB interface [X9] Digital inputs [X17] CANopen interface [X18] Analogue input [X19] Digital outputs [X20] microsd card slot Festo YJKP-EN 1606 English 3

4 YJKP 5.3 Electrical installation CMMP-AS Power supply [X9] Digital control interface [X1] CANopen interface [X4] Motor [X6] Encoder [X2B] Commissioning Maintenance Safety instructions Cleaning Repair Dismounting Safety instructions Recycling A Technical appendix A.1 General product characteristics A.2 Technical data of the main components A.3 Product weight A.4 Operating and storage conditions A.5 Explanation on vibration and shock severity level Festo YJKP-EN 1606 English

5 1 Requirements for product use 1 Requirements for product use 1.1 Target group Provide this documentation to the following persons: Design engineer Machine manufacturer Installer Commissioner Only qualified personnel may perform mounting, installation, commissioning, maintenance and disassembly of the product. Qualified personnel must be familiar with: Mounting and operation of mechatronic systems Installation and operation of electrical control systems Regulations for accident prevention and occupational safety Documentation and mode of operation of the product 1.2 Intended use This product is a module for execution of joining tasks with monitoring of the joining process. The module is used within machines or automated systems with a higher-order controller. Only use the product as follows: In perfect technical condition In its original condition, without unauthorised modifications Within the limits of the product defined by the technical data In an industrial environment Note In the event of damage caused by unauthorised manipulation or other than intended use, the guarantee is invalidated and the manufacturer is not liable for damages. 1.3 Foreseeable misuse Never use the product as follows: With unauthorised modifications or alterations to the product In an invalid mounting position With load limits exceeded Without a risk assessment of the complete system Without a safety concept for the complete system Festo YJKP-EN 1606 English 5

6 1 Requirements for product use 1.4 Applicable documents The complete description of the Servopress kit includes the following documents: Designation Web Help YJKP Description CECC-X-M1-MV Brief instruction CECC-X-M1-MV CMMP-AS description CMMP-AS brief description EMMS-AS description EMMS-AS brief description ESBF-BS description ESBF-BS brief description Content Operation of the software for the Servopress kit YJKP Configuration and parameterisation with CODESYS Description of the interfaces and commissioning Detailed description Instructions and important notes on mounting, electrical installation and maintenance Detailed description Instructions and important notes on mounting, electrical installation and maintenance Detailed description Instructions and important notes on mounting, electrical installation and maintenance Tab. 1.1 Documentation on the Servopress kit All available documents on the product ( Range of applications and certifications The range of application and certifications of the individual components of the kit are described in separate documents ( Service Please consult your regional Festo contact if you have any technical problems. 6 Festo YJKP-EN 1606 English

7 2 Transport and storage 2 Transport and storage Note Damage to the product due to incorrect transport. Observe the transport labelling and information on the packaging. 1. Transport the product to the installation/storage location in its packaging and set it down on a firm and flat base. 2. When storing the product please observe the storage conditions ( A.4 Operating and storage conditions). Note Damage to the product due to incorrect unpacking. Observe the labelling for unpacking on the packaging. Use appropriate tools. Parts of the packaging are large and heavy: Do not let any parts fall onto the product. Use suitable aids to raise and lower the product (e.g. crane). 3. Remove the packaging in accordance with the printed sequence. 2.1 Restraints in the packaging Transport restraints prevent uncontrolled movement of the product in the packaging during transport and installation. The product is provided with the following designated transport restraints: Transport screws Cable ties Fig. 2.1 Festo YJKP-EN 1606 English 7

8 3 Product overview 3 Product overview 3.1 Servopress Kit aj 3 aa 2 ab 1 ad ac 1 Electric cylinder ESBF-BS 2 Servo motor EMMS-AS 3 Motor cable and encoder cable 4 Sensor cable 5 Motor controller CMMP-AS 6 LAN cable at the CMMP-AS 1) 7 LAN cable at the CECC-X-M1-YJKP 1) 1) Not included in the scope of delivery of the kit. Fig. 3.1 Product overview, Servopress Kit 8 Control CECC-X-M1-YJKP 9 CANopen cable 1) aj Higher-order controller 1) aa LAN cable to the higher-order controller 1) ab Switch 1) ac Personal computer/tablet PC 1) ad Force sensor 8 Festo YJKP-EN 1606 English

9 3 Product overview Controller CECC-X-M1-YJKP aa aj Ethernet interface [X8] 2 USB interface [X9] 3 Functional earth connection 4 Status LEDs 5 microsd card slot 6 Power supply [X5] for digital outputs 7 CANopen interface [X18] 2) In accordance with intended use, the reserved interfaces must not be used. Fig. 3.2 Control CECC-X-M1-YJKP 8 Digital inputs [X17] 9 Analogue inputs [X19] aj I/O interfaces [X2, X3, X4] aa Power supply [X1] All unnamed connections are reserved 2) Status LEDs The product is equipped with the following status LEDs Fig : Status LED Meaning Status LED Meaning Run Application status Net Device detected Error Error Mod Reserved Tab. 3.1 Festo YJKP-EN 1606 English 9

10 3 Product overview Motor controller CMMP-AS aj aa ab Front Top view Bottom view 1 Activation of CANopen terminating resistor 8 Power supply [X9] 2 CANopen interface [X4] 9 PE connection 3 Ethernet interface [X18] aj Encoder connection [X2B] 4 7-segment display aa Motor connection [X6] 5 Reset button ab Digital control interface [X1] 6 Status LEDs 7 Digital interface for STO function [X40] All unnamed connections are reserved 1) 1) In accordance with intended use, the reserved interfaces must not be used. Fig. 3.3 Motor controller CMMP-AS Status LEDs The product is equipped with the following status LEDs Fig : Status LED Meaning Status LED Meaning Ready/Error Status CAN CAN bus status display Enable Enable Tab Festo YJKP-EN 1606 English

11 3 Product overview Connecting cables Component Connection Cable/plug Purpose CECC-X-M1-YJKP [X1] NECC L2G4 C1 1) Power supply to device [X5] NECC L2G2 C1 1) Power supply for digital outputs [X2] NECC L2G8 C1 1) I/O interface [X3] NECC L2G6 C1 1) [X4] NECC L2G4 C1 1) [X17] 2 x NECC L2G6 C1 1) Digital inputs [X19] NEBU M12G5 E x LE3 Analogue input for force sensor (sensor cable) [X8] Standard LAN patch cable 2) Ethernet connection [X18] NECC L2G4 C1 1) CANopen interface CMMP-AS [X4] Sub-D 9-pin, socket 1)2) and [X9] 1) Power supply [X1] Sub-D, 25-pin, pin 1) Digital control interface [X18] Standard LAN patch cable 2) Ethernet connection [X6] NEBM M23G6 E x N LE7 Motor cable for EMMS-AS [X2B] NEBM M12W8 E x N S1G15 Encoder cable for EMMS-AS 1) Plug for customer-provided cable. 2) Not included in the scope of delivery of the kit. Tab. 3.3 Connection and plug Festo YJKP-EN 1606 English 11

12 4 Mounting 4 Mounting 4.1 Preparation Installation space The installation space required for the product depends on the following factors: Stroke of the electric cylinder ( Attachment position and type of motor Mounting surface The mounting surface must exhibit the following characteristics: Torsionally rigid Free of stress Sufficient strength to absorb the maximum forces Sufficient evenness Transport locks Transport locks of the individual components of the kit are described in separate documents ( 12 Festo YJKP-EN 1606 English

13 4 Mounting 4.2 Installation Warning Unexpected movement of the product. Risk of impact and crushing injuries. Before working on the product, switch off the power supply and secure it against being switched on again. When lifting the product, perform the following measures: Secure movable components with transport locks to prevent unexpected movement. Observe the product weight. Observe the position of the centre of gravity. Use suitable lifting gear. Use all of the transport lugs. Adjust the lifting speed. When securing the product, perform the following measures: Secure the product in a professional manner. Only use the supplied mounting components. Secure the screw connections. Make sure the mounting surface is sufficiently strong to absorb the maximum forces. Mounting of the individual components of the kit is described in separate documents ( If you require additional support during the mounting: Please contact your regional Festo contact person. Additional information can be found online ( Mounting of force sensor Note If the fixture for fastening the force sensor hits against the sensor housing, the preload force of the tightening torque can influence the sensor as a tensile force. Use lock nut. Do not screw the lock nut up to the stop on the ESBF-BS. Do not screw the sensor tool up to the stop on the sensor. Further information can be found in the documentation for the force sensor ( Festo YJKP-EN 1606 English 13

14 5 Installation 5 Installation 5.1 Safety instructions Warning Unexpected movement of the product. Risk of impact and crushing injuries. Before working on the product, switch off the power supply and secure it against being switched on again. During installation, observe the documentation for the individual components of the kit. 5.2 Electrical installation CECC-X-M1-YJKP Caution Electric voltage Injuries caused by electric shock, damage to the machine and system. For the electrical power supply, use only PELV circuits in accordance with IEC /EN (Protective Extra-Low Voltage, PELV). Observe the general requirements IEC /EN of the PELV power circuits. Use only voltage sources that ensure a reliable electric separation from the mains network in accordance with IEC /EN Use an external overload protection for the power supply of the device. Connect circuits for power supply of the device [X1] ( 5.2.1) and power supply for digital outputs [X5] ( 5.2.2). In each case, pay attention to the required current consumption Power supply [X1] for device, digital and analogue inputs Residual current for all supplied ports: of which intrinsic current consumption: 750 ma 200 ma Terminal Connection Usage X U+ power supply X1.2 0 U load X1.3 Functional earth X1.4 Reserved Tab. 5.1 Connection, power supply 14 Festo YJKP-EN 1606 English

15 5 Installation Power supply [X5] for digital outputs Residual current for all supplied ports: 5 A Terminal Connection Comments X U+ power supply (24 V DC) X5.2 0 U ground (GND) Tab. 5.2 Connection, power supply for digital outputs I/O interface [X2, X3, X4] Terminal Connection Usage X2.0 X2.7 8 digital inputs Configurable as step enabling conditions in the sequencer of the press process: DI1 DI8 X3.0 6 digital inputs Start press process X3.1 Manual operating mode X3.2 Automatic operating mode X3.3 Start homing X3.4 Acknowledge error X3.5 Terminate press process 1) X X4.3 4 digital outputs Configurable as output signals in the sequencer of the press process: DO1 DO4 X4.4 X4.7 Reserved 2) 1) Input is low active. Process termination if input = FALSE. 2) In accordance with intended use, the reserved connections must not be used. Tab. 5.3 I/O interface connection Festo YJKP-EN 1606 English 15

16 5 Installation Ethernet interface [X8] The Ethernet interface Fig is designed as an RJ45 socket and supports gigabit LAN. The following protocols are supported: EtherNet/IP (server) Modbus TCP (server) Control via Ethernet (TCP/IP) The interface [X10] is not supported. The controller cannot be used as a switch. The Ethernet interface is used to configure and parameterise the system through a personal computer/tablet PC connected to the network. With a web browser, the servo presses kit can be commissioned after the mechanical and electrical installation. Control and process data can be exchanged with a higher-order controller through this interface during the run-time of the system. A requirement for this is integration of the CECC-X-M1-YJKP in the local network. Minimum requirement for a personal computer/tablet PC Web browser with Java Script and support of HTML5 Canvas, e.g. Firefox, Chrome, Internet Explorer Version 9 Screen resolution 1024 x 768 pixels Access is through entry in the address line: address>:8080/servo_press_kit.htm Example: Note Unauthorised access to the product can cause damage or malfunctions. When connecting the product to a network: Protect the network against unauthorised access. Measures to protect the network include: firewall, Intrusion Prevention System (IPS), network segmentation, virtual LAN (VLAN), virtual private network (VPN), security at physical access level (port security). Further information directives and standards on information technology security, e.g. IEC 62443, ISO/IEC An access password only protects against unintentional modification USB interface [X9] The USB interface Fig is compatible with the USB 3.0 and USB 2.0 standards. It is suitable for USB flash drives with plug type A. Supported function: storage of results of press processes Hinweis Damage to the product Only use USB components with a current consumption 0.9 A. 16 Festo YJKP-EN 1606 English

17 5 Installation Digital inputs [X17] The digital inputs, configured in 3-wire connection technology, are not galvanically separated. The ground potential for all inputs relates to GND of the power supply [X1]. Use 3 adjacent terminals when connecting sensors with a 3-wire configuration. Terminal Connection Usage X VDC Power supply for sensor at input 9 X Input DI9 Configurable as step enabling conditions in the sequencer of the press process. X GND logic Power supply for sensor at input 9 X VDC Power supply for sensor at input 10 X Input DI10 Configurable as step enabling conditions in the sequencer of the press process. X GND logic Power supply for sensor at input 10 X VDC Power supply for sensor at input 11 X Input DI11 Configurable as step enabling conditions in the sequencer of the press process. X GND logic Power supply for sensor at input 11 X VDC Power supply for sensor at input 12 X Input DI12 Configurable as step enabling conditions in the sequencer of the press process. X GND logic Power supply for sensor at input 12 X VDC Power supply for safety acknowledgement X Acknowledgement Safety acknowledgement contact from the safety PLC X GND logic Power supply for safety acknowledgement X X Reserved 1) X X Reserved 1) X X Reserved 1) 1) In accordance with intended use, the reserved connections must not be used. Tab. 5.4 Digital inputs connection Note Use only PNP sensors at all inputs. Festo YJKP-EN 1606 English 17

18 5 Installation CANopen interface [X18] Connect with motor controllers CMMP-AS [X4]. The connecting cable between the controller CECC-X-M1-YJKP and the motor controller CMMP-AS is not within the scope of delivery and is also not offered as accessories, since the cable length in the control cabinet can vary considerably due to the arrangement of the individual components. The connection is established via a cable provided by the customer. CECC-X-M1-YJKP [X18] CMMP-AS [X4] Plug NECC L2G4 C1, 4-pin, socket Sub-D plug connector, 9-pin, pin Tab. 5.5 CANopen connecting cable Terminal Connection Usage X18.1 CAN_H 1) CAN Bus signal (dominant high) X18.2 CAN_L 1) CAN Bus signal (dominant low) X18.3 CAN_GND CAN Ground X18.4 CAN_SHLD Connection to functional earth 1) No terminating resistor necessary; ports are connected internally via a resistor. Tab. 5.6 CANopen interface terminal allocation Analogue input [X19] The analogue inputs, configured in 3-wire connection technology, are not galvanically separated. The ground potential of the input X19.0 relates to GND of the power supply [X1]. An incoming signal is digitised with a 14 bit resolution. Terminal Connection Usage X V DC Power supply for force sensor X Input ma Evaluation of the sensor signal through servo presses software X GND logic Power supply for force sensor X X Reserved 1) X X Reserved 1) X X Reserved 1) 1) In accordance with intended use, the reserved connections must not be used. Tab. 5.7 Analogue input terminal allocation 18 Festo YJKP-EN 1606 English

19 5 Installation Digital outputs [X20] The digital outputs, configured in 2-wire connection technology, are galvanically separated. The current load for each output is 0.5 A. The ground potential for all outputs relates to GND of the power supply [X5]. All outputs are protected against short circuit and thermal overload. Note Use only PNP circuits at all outputs. 24 V IO X20.x.1 P GND IO X5.1 X5.2 X20.x.2 N PNP circuit Fig. 5.1 PNP circuits for digital outputs Use 2 adjacent terminals when connecting a consumer. Terminal Connection Allocation Comments X Signal P Faults 0.5 A per channel, SSR 2) X Reserved 1) X Signal P Servo press ready for operation 0.5 A per channel, SSR 2) X Reserved 1) X Signal P Homing requirement 0.5 A per channel, SSR 2) X Reserved 1) X Signal P Press result OK 0.5 A per channel, SSR 2) X Reserved 1) X Signal P Press result not OK 0.5 A per channel, SSR 2) X Reserved 1) X X Reserved 1) X X Reserved 1) X X Reserved 1) 1) In accordance with intended use, the reserved connections must not be used. 2) SSR: Solid State Relay Tab. 5.8 Digital outputs terminal allocation microsd card slot The microsd card slot is located on the side of the device Fig Note Use only the microsd card included in the scope of delivery. Festo does not accept any warranty for the use of other microsd cards. Plug the microsd card in at the CECC-X-M1-YJKP so the system can run. Supported function: storage of results of press processes Festo YJKP-EN 1606 English 19

20 5 Installation 5.3 Electrical installation CMMP-AS Power supply [X9] Connect the power supply in accordance with the following table. Force range Power supply Up to 4 kn 230 V AC 7 kn and more 3 x 230 V AC Tab. 5.9 Power supply of the CMMP-AS for the servo presses kit Further information can be found in the documentation for the CMMP-AS ( Digital control interface [X1] For CMMP-AS: Use D-sub plug, 25-pin, socket. Pin allocation [X1] Pin no. Connection Usage Connection 13 Reserved 1) 25 Reserved 1) 12 Reserved 1) 24 Reserved 1) 11 DIN9 Fieldbus data profile (CiA 402, FHPP) GND 23 DIN8 Fieldbus activation communication +24 V DC 10 Reserved 1) 22 Reserved 1) 9 DIN5 Controller enable through safety control +24 V DC 21 DIN4 Output stage enable +24 V DC 8 DIN3 Fieldbus offset node number bit 3 GND 20 DIN2 Fieldbus offset node number bit 2 GND 7 DIN1 Fieldbus offset node number bit 1 Tab DIN0 Fieldbus offset node number bit 0 Tab Reserved 1) 18 Reserved 1) 5 Reserved 1) 17 Reserved 1) 4 Reserved 1) 16 DIN13 Fieldbus transmission rate bit V DC 3 DIN12 Fieldbus transmission rate bit 0 GND 15 Reserved 1) 2 Reserved 1) 14 Reserved 1) 1 Reserved 1) 1) In accordance with intended use, the reserved connections must not be used. Tab Digital control interface pin allocation 20 Festo YJKP-EN 1606 English

21 5 Installation CMMP-AS- C2-3A-M0 C5-3A-M0 C5-11A-P3-M0 C10-11A-P3-M0 Pin X1.7 GND GND +24 V DC +24 V DC Pin X1.19 GND +24 V DC GND +24 V DC Tab Pin allocation dependent on the CMMP-AS variant CANopen interface [X4] Connect to connection [X18] of the controller CECC-X-M1-YJKP. The connecting cable between the controller CECC-X-M1-YJKP and the motor controller CMMP-AS is not within the scope of delivery and is also not offered as accessories, since the cable length in the control cabinet can vary considerably due to the arrangement of the individual components. The connection is established via a cable provided by the customer. CMMP-AS [X4] D-sub plug connector, 9-pin, pin CECC-X-M1-YJKP [X18] Plug NECC L2G4 C1, 4-pin, socket Tab CANopen connecting cable Pin allocation [X4] Pin no. Designation Description Terminal CECC Not assigned 6 CAN_GND Galvanically connected to GND in the X18.3 motor controller 2 CAN_L Negative CAN signal (dominant low) X CAN_H Positive CAN signal (dominant high) X CAN_GND Galvanically connected to GND in the X18.3 motor controller 8 Not assigned 4 Not assigned 9 Not assigned 5 CAN_SHLD Screening X18.4 Tab Pin assignment of CANopen interface Festo YJKP-EN 1606 English 21

22 5 Installation Motor [X6] Use the motor cable included in the scope of delivery Fig Further information can be found in the documentation for the EMMS-AS ( Encoder [X2B] Use the encoder cable included in the scope of delivery Fig Further information can be found in the documentation for the EMMS-AS ( Note For kits with single-turn encoders, each restart results in a loss of the reference position. Homing is therefore required after each restart. 22 Festo YJKP-EN 1606 English

23 6 Commissioning 6 Commissioning The first steps in commissioning the Servopress Kit are made with the help of the Festo Field Device Tool (FFT Requirements PC with FFT as well as control and motor controller are connected over the same network Participants (control, motor controller) are connected directly over a switch Preparations with the FFT Set network parameters of the control CECC-X-M1-YJKP. Set network parameters of the CMMP-AS motor controller. Optional: Update firmware and software. Firmware update of the control CECC-X-M1-YJKP Firmware update for motor controller CMMP-AS Software update of the Servopress software on the control CECC-X-M1-YJKP Examples with explanations can be found in the application notes from Festo ( Festo YJKP-EN 1606 English 23

24 7 Maintenance 7 Maintenance 7.1 Safety instructions Warning Unexpected movement of the product. Risk of impact and crushing injuries. Before working on the product, switch off the power supply and secure it against being switched on again. Maintenance of the individual components of the kit is described in separate documents ( Cleaning Note Only clean the product in exceptional circumstances by using non-abrasive cleaning agents and a soft cloth. Cleaning of the individual components of the kit is described in separate documents ( Repair Repair of the individual components of the kit is described in separate documents ( If you require support for repairs: ( Please contact your regional Festo contact person. 24 Festo YJKP-EN 1606 English

25 8 Dismounting 8 Dismounting 8.1 Safety instructions Warning Unexpected movement of the product. Risk of impact and crushing injuries. Before working on the product, switch off the power supply and secure it against being switched on again. When lifting the product, perform the following measures: Secure movable components with transport locks to prevent unexpected movement. Observe the product weight. Observe the position of the centre of gravity. Use suitable lifting gear. Use all of the transport lugs. Adjust the lifting speed. Dismounting of the individual components of the kit is described in separate documents ( Recycling Incorrect disposal is harmful to the environment. Observe local regulations regarding disposal and the environment. Observe local regulations for disposal of modules. Use lubricants (greases, oils) in accordance with the applicable regulations for health and safety and hazardous substances. Festo YJKP-EN 1606 English 25

26 A Technical appendix A Technical appendix A.1 General product characteristics Servopress Kit YJKP Variants Maximum pressing force [kn] Maximum payload [kg] Control CECC-X-M1-YJKP 3) Motor controller CMMP-AS-...-M0 4) C2-3A C5-3A C5-11A-P3 C10-11A-P3 Servo motor EMMS-AS-...-HS M 70-S 100-S 100-M 140-L RM... Encoder, multi-turn absolute RS... Encoder, single-turn absolute R...B Holding brake Electric cylinder ESBF-BS-...-5P 32-a 40-a 50-a 63-a 80-a 100-a Working stroke a [mm] 100, 200, 300, 400 Spindle pitch [mm] 5 Repetition accuracy [mm] ± 0.01 ± ± 0.01 Feed speed [mm/s] Acceleration 1) [m/s²] 2 Deceleration 2) [m/s²] 2 Quick-stop deceleration [m/s²] 5 Motor attachment position Axial, parallel Vibration and shock resistance 5) SG2/SG2 Force sensor SKDA-...-AB Maximum overload [kn] ± 1.5 ± 3.75 ± ± 15 ± 30 ± 37.5 Scanning frequency [Hz] 1000 Accuracy of measurement [%FS] 0.5 Vibration and shock resistance 5) SG3/SG2 PLC interface Ethernet Duty cycle [%] 100 6) Mounting position any 1) Acceleration for positioning procedures 2) Deceleration when force is reached 3) Tab. A.2 4) Tab. A.3 5) In accordance with IEC /EN A.5 Explanation on vibration and shock severity level 6) The system can permanently press with nominal force against a component/load (with v less than 50 mm/s). Tab. A.1 Technical data YJKP 26 Festo YJKP-EN 1606 English

27 A Technical appendix A.2 Technical data of the main components Control CECC-X-M1-YJKP Operating voltage [X1, X5] [V DC] Operating voltage [X21] [V DC] Current consumption nominal at 24 VDC [ma] 200 Protection against polarity reversal No Memory card Supported type microsd Capacity [GByte] 32 File system FAT32 Analogue input [X19] Input signal [I] ma Resolution Bit 14 Hardware Processor (CPU) Dual core, 2 x 866 MHz Total main memory MByte 512 Fan noise LpAeq (1 m distance) [db(a)] 35.7 Tab. A.2 Technical data CECC-X-M1-YJKP Motor controller CMMP-AS- C2-3A-M0 C5-3A-M0 C5-11A-P3-M0 C10-11A-P3-M0 Nominal voltage [V DC] 24 ±20 % Nominal current 1) [A] Maximum current for holding brake [A] 1 2 With higher power requirements of the holding brake Documentation GDCP-CMMP-M0-HW-... Type of mounting Screwed onto sub-base Display 7-segment display Protocol ModBus TCP, Ethernet/IP, TCP/IP Dimensions [mm] 202x66x x66x x79x247 (HxWxD) 2) Mounting plate dimensions [mm] 248x61 297x75 1) Plus current consumption from an existing holding brake and I/Os 2) Without plugs, shield screw and screw heads Tab. A.3 Technical data CMMP-AS Note With a warm motor and a supply voltage that is too low (outside of tolerance), the motor's brakes cannot open 100%, which can lead to premature wearing of the brake. Festo YJKP-EN 1606 English 27

28 A Technical appendix A.3 Product weight Servopress Kit YJKP CECC-X-M1-YJKP [kg] 0.41 CMMP-AS-...-M0 [kg] EMMS-AS-...-HS M 70-S 100-S 100-M 140-L Basic weight [kg] Additional weight of brake [kg] Electric cylinder ESBF-BS-...-5P 32-a 40-a 50-a 63-a 80-a 100-a Basic weight with 0 mm [kg] stroke Additional weight [kg] per 100 mm stroke Force sensor SKDA-...-AB Basic weight [kg] Connecting kit Parallel kit [kg] Axial kit [kg] Tab. A.4 A.4 Operating and storage conditions Characteristic Storage temperature [ C] Storage location Dry, solid and flat base 2) Maximum shelf life 48 months Ambient temperature [ C] Air humidity [%] 0 90 (non-condensing) Corrosion resistance class CRC 0 Permissible setup altitude above sea level with rated output [m] 1000 With power reduction 1) [m] ) Above 1000 m above sea level, performance reduction of 1 % per 100 m 2) In the original packaging Tab. A.5 28 Festo YJKP-EN 1606 English

29 A Technical appendix A.5 Explanation on vibration and shock severity level Vibration load Frequency range [Hz] Acceleration [m/s 2 ] Deflection [mm] SL1 SL2 SL1 SL2 SL1 SL ±3.5 ± ±0.15 ± Tab. A.6 Shock load Acceleration [m/s 2 ] Duration [ms] Shocks per direction SL1 SL2 SL1 SL2 SL1 SL2 ±150 ± Tab. A.7 Continuous shock load Acceleration [m/s 2 ] Duration [ms] Shocks per direction ± Tab. A.8 Festo YJKP-EN 1606 English 29

30 A Technical appendix 30 Festo YJKP-EN 1606 English

31

32 Copyright: Festo AG & Co. KG Postfach Esslingen Germany Phone: Fax: Reproduction, distribution or sale of this document or communication of its contents to others without express authorization is prohibited. Offenders will be liable for damages. All rights reserved in the event that a patent, utility model or design patent is registered. service_international@festo.com Internet: Original: de

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ]

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ] Controller CECC-X-M1 Brief description Controller CECC X M1 CECC X M1 MV CECC X M1 MV S1 8079349 2017-09a [8074647] PI PROFIBUS PROFINET, CANopen, CODESYS, EtherCAT, EtherNet/IP, IO-Link, and MODBUS are

More information

Motor controllers CMMO-ST

Motor controllers CMMO-ST q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Controllers CECC Key features

Controllers CECC Key features Key features Application Controller State-of-the-art programming The controllers CECC are modern, compact and versatile controllers that enable programming with CODESYS according to IEC 61131-3. CODESYS

More information

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Controller CMXH. Description STO. Safe Torque Off (STO) [ ] Controller CMXH Description STO Safe Torque Off (STO) 8062612 1603 [8062614] CMXH Translation of the original instructions CMXH-STO-EN Identification of hazards and instructions on how to prevent them:

More information

Controller CMXH-ST2 Key features

Controller CMXH-ST2 Key features Key features At a glance The controller controls two servo motors which drive an H-shaped rotating toothed belt. The toothed belt moves a slide, whose position is calculated by the controller from the

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ] System CPX-E IO-Link master module CPX-E-4IOL- Description Protocol IO-Link Function Parameterisation 877 27-7 [879] IO-Link master module CPX-E-4IOL- Original instructions CPX-E-4IOL- -E N IO-Link is

More information

Modular controllers CECX

Modular controllers CECX Key features At a glance Versatile The controller is functionally designed as a master and motion controller. It is a powerful control unit that can Economical simultaneously execute both comprehensive

More information

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) XPSMCMx Fieldbus Expansion Modules EAV8283001 12/2014 XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) 12/2014 EAV8283001.00 www.schneider-electric.com The information provided

More information

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ]

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ] CPX-E-CEC-... Controller Description Function, Parameterisation 8071235 8071235 2018-09 [8071237] Translation of the original instructions CODESYS, EtherCAT, MODBUS are registered trademarks of the respective

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

Servo press kits YJKP

Servo press kits YJKP Characteristics At a glance The servo press kit and its associated application software can be used to respond quickly and flexibly to a range of press processes. It is a great alternative to complex and

More information

Motor controllers CMMD-AS, for servo motors

Motor controllers CMMD-AS, for servo motors Key features Comparison of motor controllers Motor controller CMMP-AS CMMS-ST for motor type Servo motor Stepper motor Positioning records 255 63 Measuring system Analogue/incremental/absolute Incremental

More information

Motor controllers CMMS-ST, for stepper motors

Motor controllers CMMS-ST, for stepper motors Key features Performance characteristics Compactness Motion control Small dimensions Full integration of all components for controller and power section, including RS232 and CANopen interface Integrated

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date: Operating instructions for AX5801 TwinSAFE drive option card for the AX5000 servo drive Version: 1.2.0 Date: 2016-03-15 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the manual 3 1.1.1

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

Sensor interface CASM

Sensor interface CASM Overview Servo-pneumatic drive technology Positioning and Soft Stop applications as an integral component of the valve terminal CPX the modular peripheral system for decentralised automation tasks. The

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date: Documentation Sixteen channel digital output module with D-Sub Connector Version: Date: 2.0.0 2017-11-20 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety

More information

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date: Documentation Accessory for servo drives of the series AX5000 and AX2000 Version: Date: 1.8 2018-01-16 Contents Contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Documentation Issue Status...

More information

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ] Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date: Documentation KM2604 and KM2614 Four channel relay module Version: Date: 2.1.0 2017-12-01 Tabel of contents Tabel of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

Control blocks CPX-CEC- -V3

Control blocks CPX-CEC- -V3 Key features Application Controller The control blocks CPX-CEC- -V3 are modern control systems for CPX terminals that enable programming with CODESYS to IEC 61131-3. Programming in a global language CODESYS

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01 PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ] CPX-Terminal Brief description CPX analogue I/O modules CPX-2AE CPX-4AE CPX-2AA English 8080173 2017-11e [8080175] Translation of the original instructions Documentation on the product For all available

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1 Operating Instructions Control Unit SGTRS 3X8 Version 1 100597 SGTRS 318 110 V= 100596 SGTRS 38 4 V= Original instructions GmbH & Co KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel: +49 731 0610 Fax: +49

More information

Motor units MTR-DCI, intelligent servo motors

Motor units MTR-DCI, intelligent servo motors -U- Type discontinued Motor units MTR-DCI, intelligent servo motors Key features General information The motor unit MTR-DCI is an innovative motor with integrated power electronics for positioning tasks.

More information

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date: Documentation Sixteen Channel Digital Output Module with D-Sub Connector Version: Date: 2.0 2016-08-03 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01 ABB Drives User s Manual Modbus Adapter Module RMBA-01 Modbus Adapter Module RMBA-01 User s Manual 3AFE 64498851 REV A EN EFFECTIVE: 1.3.2002 2002 ABB Oy. All Rights Reserved. Safety instructions Overview

More information

Pressure sensors SDE1, with display

Pressure sensors SDE1, with display Product range overview Method of measurement Piezoresistive pressure sensor with display Operating voltage Measured variable Pressure measuring range Pneumatic connection Type of mounting Electrical output

More information

Motor unit MTR-DCI. Brief overview MTR-DCI. English d [ ]

Motor unit MTR-DCI. Brief overview MTR-DCI. English d [ ] Motor unit MTR-DCI Brief overview MTR-DCI English 8076565 2017-12d [8076567] Translation of the original instructions Documentation on the product For all available product documentation www.festo.com/pk

More information

Motor controllers SFC-DC

Motor controllers SFC-DC Key features Hardware The motor controller SFC-DC serves as a positioning controller and closed loop position controller Available with or without control panel Thanks to IP54 protection, the motor controller

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Electronic Rotational Speed Monitoring Device Type EDO Device Identification No.: 93.045 508.001 /.005 /.007 /.012 OPERATING INSTRUCTIONS 2 CE-Sign an Conformity The device meets the requirements of the

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

Motor controller SFC-DC

Motor controller SFC-DC Motor controller SFC-DC Brief overview SFC-DC-...-IO SFC-DC-...-PB SFC-DC-...-CO SFC-DC-...-DN English 8081484 2018-01f [8081486] Translation of the original instructions Documentation on the product For

More information

CMC III Temperature/Humidity Sensor

CMC III Temperature/Humidity Sensor CMC III Temperature/Humidity Sensor DK 7030.111 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III temperature/humidity sensor (referred to hereafter

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions DIN RAIL ELECTRONIC FAN SPEED Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date: Installation- and Operating instructions for CU8005-0000 4-Port USB 2.0 Hub Version: 1.3 Date: 2018-04-27 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

Motor controllers CMMP-AS, for servo motors

Motor controllers CMMP-AS, for servo motors Key features Comparison of motor controllers Motor controller CMMP-AS CMMS-ST for motor type Servo motor Stepper motor Positioning records 255 63 Measuring system Analogue/incremental/absolute Incremental

More information

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date: Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) 5 Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com (en) Operating instructions 80595 0a [80595] aj 9 8 Housing cover Inspection window

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date: Installation- and Operating instructions for CU8006-0000 4-Port USB 3.0 Hub Version: 1.1 Date: 2018-04-27 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

Measuring modules CPX-CMIX

Measuring modules CPX-CMIX Key features At a glance Movement and measurement in one, as an integral component of the valve terminal CPX the modular peripheral system for decentralised automation tasks. The modular design means that

More information

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

Parallel kinematic system with control system

Parallel kinematic system with control system Parallel kinematic system with control system EXPT- -C Description Commissioning 8037713 1411a [8037707] EXPT- -C Translation of the original instructions GDCP-EXPT- -C INB-EN CODESYS is a registered trademark

More information

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions (PS) Fully Configurable Galvanic Isolator Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

Brief description FSM MOV. for the ARS 2000 FS series servo drives

Brief description FSM MOV. for the ARS 2000 FS series servo drives The servo drive ARS 2000 FS with safety module FSM 2.0 - MOV is a product with safety-relevant functions and is intended for installation in machines or automation systems and for use as follows: in excellent

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Motion Terminal VTEM. Description. Motion App #02. Proportional directional control valve [ ]

Motion Terminal VTEM. Description. Motion App #02. Proportional directional control valve [ ] Motion Terminal VTEM Description Motion App #02 Proportional directional control valve 8071736 2017-12 [8071738] VTEM Translation of the original instructions VTEM-MA02-EN Firefox is a registered trademark

More information

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions IO-Link master CabinetLine AL19xx Operating instructions IO-Link master CabinetLine AL19xx 80273036/00 02/2018 1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 2 Safety instructions Read

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown - overcurrent

More information

Technical data. Your advantages

Technical data. Your advantages Technical data Nominal torque: 10.000 Nm to 25.000 Nm, bidirectional Customer-specific calibration upon request Rotational speed: 8.000 rpm Accuracy: ±0,5 % Temperature range: -30 C to +85 C Protection

More information

2D planar surface gantries

2D planar surface gantries Key features At a glance A 2D planar surface gantry (YXCF) is an assembly of several axis modules (EHM ) to produce a movement in 2D space. Can be used universally for handling light to very heavy workpieces

More information

Type Quickstart (from device Version 2)

Type Quickstart (from device Version 2) Type 8022 Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions We reserve the right to make technical changes without notice. Technische Änderungen

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions , Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

DS2020SingleAxis ExtremelyCompact ServoDrives

DS2020SingleAxis ExtremelyCompact ServoDrives DS2020SingleAxis ExtremelyCompact ServoDrives INTRODUCTION If you need the best performance and design flexibility, look no further than Moog and its expertise. With collaboration, creativity and cutting-edge

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Application Note. Modbus on CMMP-AS- -M3/M0. Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network.

Application Note. Modbus on CMMP-AS- -M3/M0. Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network. Application Note Modbus on CMMP-AS- -M3/M0 Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network. CMMP-AS M0, CMMP-AS M3 20005 Title... Modbus on CMMP-AS- -M3/M0

More information

MU110-6U. Analog output module 6 channel. User guide

MU110-6U. Analog output module 6 channel. User guide MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1 FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option

More information

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date: Documentation KM2002, KM2004, KM2008 Terminal modules with digital outputs, 24 V, 0.5 A Version: Date: 3.2.0 2017-01-23 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation...

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com aj 9 8 (en) Operating instructions 8088 09NH [8080] Original: de Positioner CMSX... English

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Motor controller CMMS-AS-C4-3A-G2. Description. STO safety function (Safe Torque Off) b [ ]

Motor controller CMMS-AS-C4-3A-G2. Description. STO safety function (Safe Torque Off) b [ ] Motor controller CMMS-AS-C4-3A-G2 Description STO safety function (Safe Torque Off) 8047494 1503b [8047486] CMMS-AS-C4-3A-G2 Translation of the original instructions GDCP-CMMS-AS-G2-S1-DE Pilz and PNOZ

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date: Documentation KM10xx Terminal Modules with Digital Inputs Version: Date: 3.1.0 2017-01-23 Product overview KM10xx Product overview KM10xx KM1002, KM1012 [} 11] - 16 inputs, input filter 3 or 0.2 ms KM1004,

More information