Digital hygrometers. FUNction

Size: px
Start display at page:

Download "Digital hygrometers. FUNction"

Transcription

1 Digital hygrometers DB-GMD FUNction Visualization of the relative humidity when the unit is connected to a humidity transmitter with current output (2 or 3 wires). The unit can supply directly the transmitters that can operate with voltage from 13.5 Vdc to 25 Vdc (not regulated). Control of optical alarms (flashing display and visualization of error code) when the sensor is opened or short circuited. Type range Main supply Resolution input db-gmd/ % 230 Vac 0.5% db-gmd/ % 12 Vac 0.5% Power supply: 230 Vac, 12 Vac, 50/60 Hz Output Vdc: DB-GMD/ Vdc DB-GMD/ Vdc Input resistance: 51 Ohm Measuring range: % Visualization: 3 digit display 0.5 % Protection: hole for 71 x 29 mm 160 g 66

2 Igrostati digitali DB-IGD Relative humidity visualization and regulation, if the unit is connected to a humidity transmitter with current output (2 or 3 wires) with: - 1 relay output for humidification and dehumidification system control; - direct supply for the transmitters that can operate with voltage from 12 to 24 Vdc (not regulated); - setting of a delay for successive load activations to avoid the load to be powered too many times; - setting of the reponse sensibility related to the humidity variations (fast or slow); - control of optical and acoustic alarms (flashed display, visualization of error code and buzzer). Type range main supply output Differential resolution db-igd/ % 230 Vac 8 A/250 Vac % 0.5% db-igd/ % 12 Vac 8 A/12 Vac % 0.5% Input : Power supply: 230 Vac, 12 Vac, 50/60 Hz Output Vdc: DB-IGD/ Vdc DB-IGD/12 12 Vdc Input resistance: 51 Ohm Campo di misura: % Setpoint: % Output : 1 SPDT relay (see schedule) Visualization: 3 digit display, indicator of output state (led) 0.5 % Working: hole for 71 x 29 mm Protection: Peso: 180 g 69

3 Digital thermometers DB-TMD Visualization of the temperature measured with NTC sensors in industrial heating and cooling applications. Control of optical alarms (flashing display and visualization of error code) if the sensor is opened or short circuided. TYPE range Power supply Resolution input db-tmd/ Vac 0.1 ntc 10K db-tmd/ Vac 0.1 ntc 10K db-tmd/ Vac/dc 0.1 ntc 10K Power supply: 230 Vac, 24 Vac, 12 Vac/dc, 50/60 Hz NTC 10K (10 kohm at 25 ) Measuring range: (NTC) Visualization: 3 digit display 0.1 between -9.5 to 99.5 and 1 on the remaining range protection: hole for 71 x 29 mm 160 g 65

4 Digital thermoregulators DB-TRD Temperature visualization and regulation measured with NTC sensors in industrial heating and cooling applications with: - 1 relay output; - setting of a delay for successive load activations to avoid the load to be powered too many times - setting of the reponse sensibility related to the temperature variations (fast or slow); - control of optical and acoustic alarms (flashing display, visualization of error code and buzzer). type RANGE MAIN SUPPLY OUTPUT DIFFERENTIAL K RESOLUTION INPUT db-trd/ Vac 8 A/250 Vac ntc 10K db-trd/ Vac 8 A/12-24 Vac ntc 10K db-trd/ Vac/dc 8 A/12 Vac ntc 10K : Power supply: 230 Vac, 24 Vac, 12 Vac/dc, 50/60 Hz NTC 10K (10 KOhm at 25 ) Measuring range: (NTC) Setpoint: Output: 1 SPDT relay (see schedule) Visualization: 3 digit display, indicator of output state (led) 0.1 between -9.9 to 99.9 and 1 on the remaining range Protection: hole for 71 x 29 mm 180 g 68

5 Digital manometers DB-PMD Visualization of the pressure, if the unit is connected to a pressure transmitter with current output (2 or 3 wires). The unit can supply directly the transmitters that can operate with voltage 17 Vdc ± 20% (non regulated). Control of optical alarms (flashing display and visualization of error code) when the sensor is opened or short circuited. TYPE range Power supply resolution input db-pmd/ (*) 230 Vac 0.1 or db-pmd/ (*) 12 Vac/dc 0.1 or (*) range must be defined during ordering. The range must be within -99 and on request the controller can be supplied with mbar, bar or psi. Power supply: 230 Vac, 12 Vac/dc, 50/60 Hz DB-PMD/ Vdc DB-PMD/ Vdc Input resistance: 100 Ohm Measuring range: see (*) Power cons.: < 1.5 W Visualization: 3 digit display 0.1 for scales with decimal point (upper scale lower or equal to 100) 1 for scales without decimal point Protection: hole for 71 x 29 mm 160 g 20,5 Vdc 67

6 Digital pressostats DB-PRD Pressure visualization and regulation, if the unit is connected to a pressure transmitter with current output (2 or 3 wires) with: - 1 relay output for increasing or decreasing pressure system control; - direct supply for the transmitters that can operate with voltage from 11 to 20.5 Vdc (not regulated); - setting of a delay for successive load activations to avoid the load to be powered too many times; - setting of the reponse sensibility related to the pressure variations (6 different speeds); - control of optical and acoustic alarms (flashed display, visualization of error code and buzzer). TYPE RANGE MAIN SUPPLY OUTPUt Differential Resolution input db-prd/ (*) 230 Vac 8 A/250 Vac o db-prd/ (*) 12 Vac/dc 8 A/12 Vac o (*) range must be defined during ordering. The range must be within -99 and on request the controller can be supplied with mbar, bar or psi. Power supply: Input resistance: Power cons.: Output: Visualization: 230 Vac, 12 Vac/dc, 50/60 Hz 100 Ohm < 1.5 W 1 SPDT relay (see schedule) 3 digit display, indicator of output state (led) 0.1 for scales with decimal point (upper scale lower or equal to 100); 1 for scales without decimal point Working: <95% Housing: ABS self-estinguishing as to UL94 V-0 protection: Dimensioni: hole for 71 x 29 mm 180 g 70

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

MOD-IO9 Modbus Input / Output Modules, Wall Mounted Product sheet MOD3.9 Type MOD-IO9 MOD-IO9 Modbus Input / Output Modules, Wall Mounted MOD-IO9 and MOD-IO9-AI have been designed to be a compact wall mounted Modbus RTU input and output module. The module

More information

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector 4.4 IPEX60D 4.4.1 Description of the connections Connector Description Connector for 24Vac/dc power supply Analogue inputs (Pb1 - Pb5, PbC) Potential free digital inputs (DI1 - DI3, DIC) Additional power

More information

MOD-RI Room Interface Modules with Modbus

MOD-RI Room Interface Modules with Modbus Product sheet MOD3.00 Type MOD-RI MOD-RI Room Interface Modules with Modbus The MOD-RI are room interface modules designed to provide room control interface for the building management systems. The MOD-RI

More information

SERIES 59. Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing

SERIES 59. Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing SERIES 59 Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing FEATURES Microprocessor-based no cumbersome menus Large 3-digit LED display permits easy

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

LLR-MOD Modbus Light Level and Occupancy Sensor

LLR-MOD Modbus Light Level and Occupancy Sensor Product sheet SN1.418 Type LLR-MOD LLR-MOD Modbus Light Level and Occupancy Sensor The LLR-MOD sensors are designed to measure Light Level (LUX) in the room spaces and have built-in RS485 Modbus communication

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

EWPC 901/A rel. 6/96 ing

EWPC 901/A rel. 6/96 ing EWPC 91A rel. 696 ing temperature controller with alarm output WHAT IT IS The EWPC 91A is a temperature controller specifically designed for refrigeration applications. The instrument includes a 1 Vdc

More information

Submittal Data Sheet WAGO Node for itm

Submittal Data Sheet WAGO Node for itm The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via

More information

HLS34 Modbus FCU/VAV Controllers installation instructions

HLS34 Modbus FCU/VAV Controllers installation instructions HLS34 Modbus FCU/VAV Controllers installation instructions The HLS34 is specifically designed for individual room temperature and zone control applications. The controllers have built-in RS-485 channel

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

Gas Controller System DGC-06

Gas Controller System DGC-06 Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN

More information

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature

More information

THERMOSTATS & CONTROLLERS

THERMOSTATS & CONTROLLERS DESCRIPTION The Belimo ZIP Economizer Series saves energy in buildings by using cool outside air as a means of cooling the indoor space. This application can drastically reduce HVAC energy costs while

More information

Controllers for compressor racks with advanced energy saving. PN08 September 2016

Controllers for compressor racks with advanced energy saving. PN08 September 2016 page 1 / 16 XC400/600 for small/medium compressor rack management Dixell introduces the new compact parametric controllers for compressor rack with. Dixell presents the XC400/600 series, dedicated to the

More information

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication

More information

Millennium Simplicity Elite Parameter Points and Quirks

Millennium Simplicity Elite Parameter Points and Quirks Millennium Simplicity Elite Parameter Points and Quirks How to access, view and change parameter settings Program Button Test Reset UP Alarms Change Data Address Down 1. Push the Program button once. The

More information

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus Product sheet SN1.411 Type RHR-MOD RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus The RHR-MOD sensors are designed to detect relative humidity and temperature in the room

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

User s manual. Programmable panel meter IPD

User s manual. Programmable panel meter IPD User s manual Programmable panel meter IPD Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN ECON-ZIP-BASE ZIP Economizer Base Unit 24 VAC ± 20%, 50/60 Hz; Class 2 power source 4 VA Base Control (ECON-ZIP-BASE) 5.5 VA Base Control with Energy Module (ECON-ZIP-BASE + ECON-ZIP-EM) Power Consumption

More information

CDR Room CO 2 and Temperature Sensor with Modbus

CDR Room CO 2 and Temperature Sensor with Modbus Product sheet SN1.404 Type CDR-MOD CDR-MOD Room CO 2 and Temperature Sensors with Modbus The CDR-MOD sensors are designed to detect carbon dioxide concentration and temperature in the room spaces and have

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Series 28 Universal Sensors

Series 28 Universal Sensors Series 8 Universal Sensors Diffuse Mode with Background Suppression See pages 548-553 Features: Sharp sensing range cut-off Choice of infrared, visible red and laser light sources Sensing Range: 400 mm,

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE Catalogue 207 CONTENTS CONTROLLERS... 4 room controllers... 5 room units... 29 control units... 24 PRODUAL 3 CATALOGUE T U R KU I C T C ON T R OL L E R S Multifunctional controllers for optimal performance

More information

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping

More information

CDD Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate

More information

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler

More information

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus Product sheet TER Type TER-MOD TER-MOD Active Room Temperature Sensors (Controllers) with Modbus The TER-MOD active sensors are designed to detect temperature in the room spaces and have built-in RS485

More information

Fast Route to Reliable Energy Savings ZIP Economizer

Fast Route to Reliable Energy Savings ZIP Economizer Fast Route to Reliable Energy Savings ZIP Economizer LCD Display Automotive quality, easy-to-read display allows easy verifi cation of set values and real time operating information Alarm Notification

More information

FX Input/Output (I/O) Modules XM07 and XM14

FX Input/Output (I/O) Modules XM07 and XM14 Product Bulletin FX I/O Modules Issue Date July 6, 2009 FX Input/Output (I/O) Modules XM07 and XM14 The FX Input/Output (I/O) Modules provide additional physical input and output points for FX field controllers

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

Options Overview. February 6, Ben Newell

Options Overview. February 6, Ben Newell Options Overview February 6, 2018 Ben Newell CERV2 Configuration Unitary All-in-One System Heat pump and dampers Fans same ECM fans as current CERV Fresh air and return filters (nom. 10 x20 ) Integrated

More information

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations.

More information

System 450 Series Modular Controls

System 450 Series Modular Controls Code No. LIT-1900549 System 450 Series Modular Controls Description System 450 is a family of modular, digital electronic controls that is easily assembled and set up to provide reliable temperature, pressure,

More information

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface Product Bulletin: FX06 Field Controller Issue Date: March 2006 FX06 Field Controller The FX06 is a compact field controller in the Facility Explorer range of products. The controller is designed specifically

More information

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin DP2500 DP0250 Differential Pressure Transmitter Product Bulletin The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air and

More information

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa MAKING MODERN LIVING POSSIBLE MCX15B electronic controller MCX15B is fitted with or without graphic LCD display. It is an electronic controller that stands on the top of the MCX range, thanks to the large

More information

Hotel Room Controller

Hotel Room Controller Full Service & Luxury Guest Room Management Solutions Delivering exceptional guest satisfaction while optimizing energy and operational efficiency Product at a Glance The (HRC) is at the heart of our Full

More information

ST-TY Space Thermostats

ST-TY Space Thermostats Page of 5 ST-TY Space Thermostats Features: Tamperproof option Bi-metallic switch mechanism reliability Technical Overview The ST-x series of wall mounting space thermostats are suitable for heating and/or

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

EXD-TEVI Economizer Controller for Tandem Compressors

EXD-TEVI Economizer Controller for Tandem Compressors Technical Bulletin EXD-TEVI is a stand-alone controller for enhanced wet vapor injection for Copeland tandem Scroll compressors in heating applications. Features EXD-TEVI Emerson solution for specified

More information

MBM - Modular I/O system IP20

MBM - Modular I/O system IP20 - Modular I/O system IP20 Input/output module digital 4-way Ordering data 4 digital inputs and outputs 55882 3-wire screw terminal block 55832 3-wire spring clamp terminal block 55852 Load weight 1) 1.00

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Communication Register Map - Uniflair Cooling

Communication Register Map - Uniflair Cooling DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R

More information

Model Number Structure

Model Number Structure Analogue Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours! Data sheet MK 20 GR Customized solution or off-the-shelf: The choice is yours! MK20-GR data sheet Looking for a quick and reliable solution? Then rely on our standard products: Our universal controls provide

More information

NOTE: Controller must be mounted to minimum of 2 ft2 (0.2m2) 20 gauge metal panel with both sides radiating.

NOTE: Controller must be mounted to minimum of 2 ft2 (0.2m2) 20 gauge metal panel with both sides radiating. Series 194 7/11/2000 6:31 AM Page 1 CP Scan#1:Desktop Folder:hold:950 Catalog:Series 194.job: Series 194 Thermistor Sensing Temperature Controller With Remote Indicating Meter Option FEATURES Relay or

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Temperature/Process Controllers Manual

Temperature/Process Controllers Manual 3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features

More information

PC2004 PRESSURE CONTROLLER

PC2004 PRESSURE CONTROLLER PC CTROLLER FRT PANEL Digital Display & Display Selector Switch The Display Selector Switch has five positions: PRESS Displays the pressure sensed at the transducer. INT SP Displays the INTERNAL SETPOINT

More information

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info DP20 Economical Multisignal Meter for Process, Temperatures and Electrical signals U.S.A.

More information

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction User's Guide 1/16 th DIN ph Controller Model 48PH2 Introduction Thank you for selecting the Extech Model 48PH2 controller. This 1/16 th DIN-size controller offers dual display, high resolution measurements,

More information

FLOW MONITOR & TRANSMITTER

FLOW MONITOR & TRANSMITTER FLS M9.02 FLOW MONITOR & TRANSMITTER SAFETY INSTRUCTIONS General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other

More information

Electronic Control Options for Automatic Control Valves. Jody Malo Singer Valve

Electronic Control Options for Automatic Control Valves. Jody Malo Singer Valve Electronic Control Options for Automatic Control Valves Jody Malo Singer Valve Control Chamber Restriction Manual Ball Valve Inlet Outlet Advantages: No power required Ease of use Been used for 80+ years

More information

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide Page 1 of 26 HygroFlex HF3 Transmitters and thermo-hygrostats Page 2 of 26 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description...

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit) Temperature Controller DIN-sized (48 x 48 mm) Temperature Controller With Digital Setting Compact, low-cost Temperature Controller Incorporates proportional adjustment and reset adjustment function. Incorporates

More information

PCM SLK- Series Inverter Specification

PCM SLK- Series Inverter Specification PCM SLK- Series Inverter Specification Page 1 of 7 General Specification Introduction Environment The inverters are designed to be outdoor types. Models In field applications, the power demands from 1.5kW

More information

Enhancing Business Performance

Enhancing Business Performance www.craftech.co.in 1 Crafting technology for your business needs About Craftech Who We Are Craftech is a young company based in Nashik, 160 Km from Mumbai the financial capital of India. We manufacture

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

Zone Pressure Touch (ZPT) Sensor - Standard Range

Zone Pressure Touch (ZPT) Sensor - Standard Range Product Identification BAPI s Touch Pressure Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air

More information

SP6R Level Controller Operation Manual

SP6R Level Controller Operation Manual SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.

More information

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U) (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications

More information

WI-I/O 9 Multi I/O Units

WI-I/O 9 Multi I/O Units WI-I/O 9 Multi I/O Units A transceiver is a wireless device made up of a transmitter and receiver. Since each module can manage both input and output signals, it can be used to monitor transducers and

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button

More information

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

MRC 7000 Proven Recording Reliability that Became the Industry Standard! Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors Pre-configured controller with display, clock and communication Room controller for thermoregulation applications, equipped with rapid access buttons for the most common functions. Communication via RS485

More information

FCU-MULTI Modbus Fan Coil Unit Controller

FCU-MULTI Modbus Fan Coil Unit Controller Product Sheet CT2.61 Controller Type FCU-MULTI FCU-MULTI Modbus Fan Coil Unit Controller FCU-MULTI is completely stand-alone operating room controller designed for room heating, cooling, ventilation, lighting

More information

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

SU500: 12.5 (318 mm) SU500CL: (438 mm) SU500: 39 (991 mm) SU500CL: 37.5 (953 mm) SU500: 3.5 (89 mm) SU500CL: 3.0 (76 mm)

SU500: 12.5 (318 mm) SU500CL: (438 mm) SU500: 39 (991 mm) SU500CL: 37.5 (953 mm) SU500: 3.5 (89 mm) SU500CL: 3.0 (76 mm) ALVARADO Supervisor 500 / 500CL Optical Monitor Lane for Bi-directional Counting Technical Specifications Dimensions Cabinet Length: Cabinet Height: Cabinet Width: SU500: 12.5 (318 mm) SU500CL: (438 mm)

More information

Zone Pressure Touch Sensor - Standard Range

Zone Pressure Touch Sensor - Standard Range Overview The Zone Pressure Touch (ZPT) Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air velocities/volumes.

More information

InCos-P Pressure sensor 20 Pa Pa

InCos-P Pressure sensor 20 Pa Pa InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.

More information

DP DP2500 DP0250

DP DP2500 DP0250 DP7000 - DP2500 DP0250 PB_DP7000_DP2500 - DP0250_07 2016 Field adjustable, multi-range differential pressure transmitters Product Bulletin The Delta Pressure transmitter series of Johnson Controls, with

More information

PowerView Model PV350 and PV380. Installation Manual Section 78

PowerView Model PV350 and PV380. Installation Manual Section 78 PowerView Model PV350 and PV380 Installation Manual 00-02-0880 2013-05-17 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications

More information

FXVMA Variable Air Volume (VAV) Box Controller

FXVMA Variable Air Volume (VAV) Box Controller FXVMA Product Bulletin FXVMA Issue Date November 21, 2008 FXVMA Variable Air Volume (VAV) Box Controller The FXVMA is an integrated assembly used to control Variable Air Volume (VAV) boxes. The FXVMA consists

More information

C7110C1001A / C7110D1009A WALL MODULES

C7110C1001A / C7110D1009A WALL MODULES HONEYWELL EXCEL 5000 OPEN SYSTEM GENERAL The C7110C1001A and C7110D1009A are combined CO2 / temperature wall modules designed for applications in indoor ventilation and air conditioning systems. In conjunction

More information

ESD, ESR, ESA, ESP, ESQ. Switching Units

ESD, ESR, ESA, ESP, ESQ. Switching Units ESD, ESR, ESA, ESP, ESQ Switching Units Selection Table for ESR Units Safety Protection Bircher Category Class Inputs Outputs Voltage Redundancy Type 3 IP 30 30/5/4 x ESD 3 IP 30 30/5/4 ESR IP 30 30/5/4

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

Tachometer Panel, PE3

Tachometer Panel, PE3 Features Plug-n-play units with factory programmed parameters 4-20 ma feedback signal Isolated relay alarm outputs Frequency input Diagnostic indicators NEMA 4 Enclosure Model PE3, Tachometer Panel Benefits

More information

ECON-ZIP-BASE. ZIP Economizer Base Module

ECON-ZIP-BASE. ZIP Economizer Base Module ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and

More information