1 PRODUCT Battery Charger

2 Model : BC 9080 Battery Charger The ICD Battery Charger is designed to supply required DC Voltage and Current to the connected load and recharge the Battery on boost charging over it maintains the battery in float mode. The Battery Charger Provide regulated DC output form 1 Phase or 3Phase AC Source with ±10% variation in the input and perform satisfactorily under various load condition. The charger select automatically float and boost mode charging when discharged battery is connected. The Battery Charger ensures complete isolation from power supply by transformer and circuit design with high end micro controller and state of control scheme. ICD Battery charger is suitable lead Acid Battery VRLA, Non VRLA and Ni-Cd Battery. Features Micro controller based design and sophisticated control scheme ensure voltage and current regulation throughout range Input Current limit by soft start when charger is ON LC Filter of adequate rating to limit required level of ripple Short circuit and over load protected Automatic float/boost changeover depends on charger status Auto phase reversal is built in when supply phase is reverse Over voltage cutoff ensures load and battery banks are safe and secure Sophisticated panel manufacturing with 7 tank painting process.

3 Technical Specification FUNCTION SINGLE PHASE THREE PHASE NOMINAL INPUT VOLTAGE (V AC) DC OUTPUT VOLTAGE (V DC) OUTPUT CURRENT (A DC) 230V AC, 1 PHASE 2 WIRE, 50HZ ± 10% 415V AC, 3 PHASE 3/4 WIRE, 50HZ ± 10% 24V/36V/48V/110V/220V 10 TO 150AMPS RANGE RIPPLE <5% RMS <2% RMS REGULATION ± 1V FOR INPUT OR LOAD VARIATION EFFICIENCY >70% >80% RECTIFIER TYPE FULL WAVE FULLY CONTROLLED RECTIFIER NOISE LEVEL <75DB <75DB FLOAT VOLTAGE ADJUST BOOST VOLTAGE ADJUST MAGNETICS TERMINALS PROTECTIONS 107% TO 114% ADJUSTABLE THROUGH POT METER (112% NOMINAL) 110% TO 117% ADJUSTABLE THROUGH POT METER (115% NOMINAL) CLASS-F INSULATION TEMPERATURE RAISE 90 O C ABOVE AMBIENT HIGH VOLTAGE WITHSTAND FOR 2.5KV AT MAXIMUM LEAKAGE CURRENT OF 5MA INPUT &BATTERY TERMINALS INBUILT LOAD TERMINALS DCDB (OPTIONAL) AC INPUT CIRCUIT BREAKER DC OUTPUT CIRCUIT BREAKER AC INPUT FUSES DC OUTPUT FUSES FAST ACTING SEMICONDUCTOR FUSES FOR RECTIFIER PROTECTION FILTER PROTECTION FUSES FUSES FOR CONTROL CIRCUIT PROTECTION METERING AC OVER LOAD AC EARTH FAULT DC EARTH FAULT OVER TEMPERATURE PROTECTION 1.DC VOLTMETER FOR OUTPUT VOLTAGE 2. DC AMMETER FOR OUTPUT CURRENT 1. DC VOLTMETER FOR OUTPUT VOLTAGE 2. DC AMMETER FOR OUTPUT CURRENT 3. AC VOLTMETER FOR INPUT VOLTAGE 4. AC AMMETER FOR INPUT CURRENT DC VOLTMETER FOR CHARGER AND LOAD VOLTAGE TYPE DIGITAL DC AMMETER FOR CHARGER AND LOAD CURRENT DIGITAL TYPE SAFETY FEATURES INDICATIONS/ANNUNCIATION SOFT START ON DC SIDE BATTERY REVERSE POLARITY SHORT CIRCUIT PROTECTION OUTPUT CURRENT LIMIT INPUT SUPPLY INDICATION CHARGER ON CHARGER IN FLOAT MODE CHARGER IN BOOST MODE CHARGER OVER VOLTAGE CHARGER OVER LOAD CHARGER FAIL/TRIP

4 OPTIONAL FEATURES FRONT PANEL CONTROLS CABINET CONSTRUCTION COOLING TYPE OPERATING TEMPERATURE CABLE ENTRY ENVIRONMENT CONDITIONS ROUTINE TESTS INPUT FUSE FAIL INDICATION RECTIFIER FUSE FAIL INDICATION FILTER FUSE FAIL INDICATION OUTPUT FUSE FAIL DC UNDER VOLTAGE DETECTION AND INDICATION DC OVER VOLTAGE DETECTION AND INDICATION FLOAT VOLTAGE ADJUST POT METER (ON DOOR) BOOST VOLTAGE ADJUST POT METER (ON DOOR) CHARGE CURRENT SET POT METER(ON DOOR) CHARGER START/STOP SELECTOR SWITCH(ON DOOR) AUTO/MANUAL SELECTOR SWITCH(ON DOOR) FLOAT/ BOOST SELECTOR SWITCH(ON DOOR) DC VOLTMETER SELECTOR SWITCH(OPTIONAL) DC AMMETER SELECTOR SWITCH (OPTIONAL) ENCLOSURE PROTECTION IP20 (IP42 IS OPTIONAL) TEXTURE / MATT FINISH RAL 7035 OR RAL 7032 SHEET METAL CONSTRUCTION FRONT AND REAR ACCESS FOR COMPONENT FLOOR MOUNTING EARTHLING BUS BAR IS PROVIDED AT BOTH SIDE OF THE PANEL. NATURAL OR FORCED COOLING 0 DEG C TO 50 DEG C GENERALLY FROM BOTTOM AS PER CUSTOMER REQUIREMENT TOP WILL BE PROVIDED OPERATING AMBIENT TEMPERATURE 0 TO 50 O C STORAGE TEMPERATURE -30 TO +70 O C HUMIDITY RANGE 0 TO 95% RH DIMENSIONAL MEASUREMENT INSULATION TEST HV TEST FUNCTION TESTS MEASURING OF RIPPLE MEASURING OF REGULATION MEASURING OF EFFICIENCY INDICATIONS AND CONTROLS FUNCTION CHECKING HEAT RUN TEST (FOR BULK IT WILL BE MUST OTHERWISE OPTIONAL) PF AND HARMONICS MEASUREMENT (OPTIONAL) TRANSIENT RESPONSE TEST

5 Scheme 1. Float cum Boost as combined It is a combination of float cum boost charger, normally it works in float mode and on mains failure battery starts supplying load current on restoration of mains depending on battery status it will switch over to boost mode for charging battery or remain in float mode. The load will see raised voltage in boost mode and load needs to withstand, otherwise ICD provides optionally voltage dropping module (VDM) to maintain load voltage with in limit FCBC without VDM FCBC with VDM 2. Float Charger and Boost Charger as separate This scheme consists of separate float charger and boost charger having transformer, controller, rectifier, filters. Float charger is designed to separately load and battery float mode requirement of current and voltage. Boost Charger is designed to supply battery charging requirement in boost mode - constant current charging.

6 Normally float charger will be in ON supplies load requirement, battery will be in trickle charging and boost charger in OFF mode. The float charger and boost charger are isolated by contractor and in float mode boost charger to and contractor also will be OFF. When battery sees boost charging is supplied float charger is isolated and boost charger will be ON, contractor ON for charging the battery In case of float charger failed, battery will be cut off from boost charger and battery will be connected to load. In this scheme load will see only maximum float voltage or battery terminal voltage FLOAT and BOOST Charger 3. Redundant float cum boost charger This scheme consists of two sets of float cum boost charger of individual current rating.both the charger are designed to supply load and charging requirement. Auto/ Manual mode of selection of FCBC1 and FCBC2 is available.in manual mode FCBC1 will be in float to meet load requirement and FCBC2 will be in battery charging mode or vice versa. The charger is designed to changeover one FCBC to another FCBC in case of failure of FCBC automatically. The good FCBC will be meets load once charging requirement Dual Float cum Boost Charger

7 4. Float charger and float cum boost charger In this scheme it has one float charger and float cum boost charger. Float charger is designed to meet load and battery trickle charging current requirement and FCBC will be in cut off. When battery needs charging, FC is disconnected from battery and load supply is maintained by FC. FCBC will be charging the battery in boost mode if needed. FCBC will be in float mode to supply load and battery in trickle mode. Interlocking is available among charger for safely and protection against short circuit on mains failure battery is completed to load with a contactor and maintain load supply. FC and FCBC Charger 800x 600 x x 600 x x 600 x A

8 800x 600 x x 600 x A 1000 x 600 x x 600 x A 1000 x 600 x x 600 x A 1200 x 600 x A 1200 x 600 x A 70A 2000 x 1000 x A 1500 x 800 x x 1000 x A 1800 x 600 x 600 x2 100A 2000 x 1000 x x 600 x 600 x2 150A

9 2000 x 1000 x x 600 x 600 x2 *SINGLE PHASE BATTERY CHARGER DIMENSIONS OUTPUT CURRENT 24V DC 48V DC 110V DC 220V DC 10A 850 X 550X X 550X X 550X X 800 X A 850 X 550X X 600 X X 600 X X 800 X A 850 X 550X X 600 X X 800 X X 800 X A 1000 X 600 X X 800 X X 800 X X 800 X A 1000 X 600 X X 800 X X 800 X X 800 X A 1200 X 800 X X 800 X X 800 X X 800 X A 1200 X 800 X X 800 X X 800 X X 800 X A 1200 X 800 X X 800 X X 800 X X 800 X A 1200 X 800 X X 800 X X 800 X X 800 X A 1200 X 800 X X 800 X X 800 X X 1000 X 800 Applications Substation Battery Charging Ni-Cd Batteries and Railway Traction Batteries Diesel Generator set Batteries Telecom Battery Charging

AIR COOLED MODULAR RECTIFIER

AIR COOLED MODULAR RECTIFIER CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range:

More information

BRC SERIES 20kW High Voltage Power Supply

BRC SERIES 20kW High Voltage Power Supply BRC SERIES 20kW High Voltage Power Supply Description UNIPOWER s line of BRC switching power supplies are notable for low ripple, fast transient response, endurance to repetitive arcing and stable output

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

99 Washington Street Melrose, MA Phone Toll Free Visit us at   INSTRUCTION MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose,

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems Features General Universal Application Data Processing Telecommunications Medical/Health Care Manufacturing/ Process Control Quality Design

More information

CI-tronic Reversing contactor Type RCI

CI-tronic Reversing contactor Type RCI Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

Laboratory Switch Mode Power Supply Series. Instruction Manual

Laboratory Switch Mode Power Supply Series. Instruction Manual Laboratory Switch Mode Power Supply Series Instruction Manual Model 72-8340 1.0 ~ 60VDC 0 ~ 1.6A 72-8345 1.0 ~ 36VDC 0 ~ 3A 72-8350 1.0 ~ 20VDC 0 ~ 5A Copyright 2008, all rights reserved Tenma Test Equipment

More information

1. Chapter 1 24/48/110/220VDC Power Supply System

1. Chapter 1 24/48/110/220VDC Power Supply System 1. Chapter 1 24/48/110/220VDC Power Supply System A. Outline of 24/48/110/220VDC Power Supply System Picture Picture 2*Rectifier module 3*Rectifier module 6*Rectifier module 10*Rectifier module Rectifier

More information

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

PCU Supervisory module for the RM 1000 series

PCU Supervisory module for the RM 1000 series Supervisory module for the RM 1000 series PCU 10.00 Microprocessor based control unit for supervision of internal and external functions in systems comprising RM 1000 rectifiers. Input power: 18-72V DC

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

LBC Series 3-phase PSU / Battery Charger

LBC Series 3-phase PSU / Battery Charger 3-phase PSU / Battery Charger The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC

More information

PRODUCT FEATURES AND ADVANTAGES

PRODUCT FEATURES AND ADVANTAGES Flatpack2 24/1800 HE 24VDC Rectifier/Converter Modules The combination of innovative design, efficiency and reliability makes the Flatpack2 HE stand out. With efficiency up to 96.2%, the losses have been

More information

DATASHEET. Ultra Capacitor Charger, UCC-4

DATASHEET. Ultra Capacitor Charger, UCC-4 DATASHEET Ultra Capacitor Charger, UCC-4 Easy installation Monitoring and surveillance of operation Balancing to save energy 90-450 V DC 3.5A Output Modular Ultra Capacitor system Document no.: 4921260003

More information

Testing Instruments Manufactured by

Testing Instruments Manufactured by Circuit Breaker Dynamic Contact Resistance Meter HISAC Ultima Circuit Breaker Dynamic Test Set with up to Six Channel Dynamic Contact Resistance Meter 24 Binary Channels (4 Main + 4 PIR per Pole, 3 Poles

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 2W 2/3/3/mA fixc lp SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 2, 3, 3 or ma Max. output power 2 W For luminaires of protection

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC W 2/3/3/7/1mA fixc lp SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 2, 3, 3, 7 or 1, ma Max. output power W For luminaires

More information

INSTRUCTION MANUAL. Triple Output DC POWER SUPPLY MODELS 1651A & 1652 MODELOS 1651A & El Manual de la Instrucción

INSTRUCTION MANUAL. Triple Output DC POWER SUPPLY MODELS 1651A & 1652 MODELOS 1651A & El Manual de la Instrucción INSTRUCTION MANUAL El Manual de la Instrucción MODELS 1651A & 1652 MODELOS 1651A & 1652 Triple Output DC POWER SUPPLY FUENTES DE PODER De Triple Salida DC Test Equipment Depot - 800.517.8431-99 Washington

More information

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Switch Mode Power Supply S8VT 120/240/480/960 W Models Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP) Discipline Engineering Standard - NSW Category Signalling Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units Reference Number SPS 30 - (RIC Standard: SC 09 10 07 00 SP)

More information

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control D1551A D1551B D1551P D1553B D1553C D1553P D1555B D1555C D1555P D155X Series Part Numbers 1A 12 volts in A box 1A

More information

POWER SOURCE FOR ELECTRON BEAM WELDING

POWER SOURCE FOR ELECTRON BEAM WELDING POWER SOURCE FOR ELECTRON BEAM WELDING Upto 20kW IONICS has designed, developed and supplied regulated power supplies for Electron Beam Welding equipment using the high frequency resonant / PWM-controlled

More information

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower

More information

SAMSUNG ELECTRO-MECHANICS CO., LTD

SAMSUNG ELECTRO-MECHANICS CO., LTD Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OLP/OTP/SCP ㅡ Non potting product Electrical

More information

Features. Applications and Benefits TRC ELECTRONICS, INC

Features. Applications and Benefits TRC ELECTRONICS, INC Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and

More information

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches S&C M Series Switch Operator Sophisticated Microprocessor Control of Overhead Distribution Switches S&C s M Series Switch Operator is a fully integrated, microprocessor-based operator that lets you automate

More information

Power Quality Book. Hipulse System Guide UPS FOR THE DIGITAL WORLD. Version 1.0

Power Quality Book. Hipulse System Guide UPS FOR THE DIGITAL WORLD. Version 1.0 4a Power Quality Book Hipulse System Guide UPS FOR THE DIGITAL WORLD Version 1.0 CONTENTS GENERAL 5 SYSTEM DESCRIPTION 7 CONFIGURATION 9 COMPONENTS 17 PERFORMANCE REQUIREMENTS 23 5 SUMMARY 5 STANDARDS

More information

SPAN CONTROLS. For Quality, Reliability And Service

SPAN CONTROLS. For Quality, Reliability And Service Span Controls Established in 1987, Span Controls is now one of the leading manufacturers of Switch Mode Power Supplies, Battery Chargers, DC-DC Converters and LED Drivers in India. Having more than 25

More information

24/48V Battery Bank Ah High Cycling Long Life

24/48V Battery Bank Ah High Cycling Long Life Outdoor Power Cabinets, 48V DC Free Cooled with Combined Air-Con. PreFactory assembled with 19 inch Power sub rack, 2 or 4 battery Shelf s, 3U DCAC Panel combined with rectifiers 2U or 4U Power Module

More information

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MODEL 102P 102R DESCRIPTION Floor Stand (Plane) Floor Stand (Modified) HTRB Burn-In System (diode) Component Burn-In

More information

Motor Controllers. On-Road AC Motor Controller. Model 1239E.

Motor Controllers. On-Road AC Motor Controller. Model 1239E. Motor Controllers Model 29E www.curtisinstruments.com The E difference A significant enhancement to the Curtis AC family, The E models utilize a powerful dual-microprocessor logic architecture to provide

More information

Instruction leaflet for the VPAK DC TO HVDC CONVERTER (1kV to 10kV)

Instruction leaflet for the VPAK DC TO HVDC CONVERTER (1kV to 10kV) Tel : +44 (0)1798 873986 Fax : +44 (0)1798 872479 e-mail : hvsales@spellmanhv.co.uk Broomers Park, Broomers Hill Lane Pulborough, W. Sussex, RH20 2RY Instruction leaflet for the VPAK DC TO HVDC CONVERTER

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC W /3/3/7/mA fixc lp SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current, 3, 3, 7 or 1, ma Max. output power W For luminaires of

More information

Multiple Output Linear DC Power Supply

Multiple Output Linear DC Power Supply Multiple Output 180W~315W Introduction The TP2000 and TP2000TK series are linear DC power supplies with 3 channels, 195W to 315W output. In constant voltage and current operations, the power supply provides

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

1. Micro Drive Load sharing application note

1. Micro Drive Load sharing application note Load sharing Application Note Page 1 of 17 1. Micro Drive Load sharing application note 1.1 Index 1. Micro Drive Load sharing application note... 1 1.1 Index... 1 1.2 Abstract... 1 1.3 Limitations and

More information

AC-DC Converter REC K10

AC-DC Converter REC K10 Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,

More information

SMARTONLINE E3 UPS SYSTEMS

SMARTONLINE E3 UPS SYSTEMS SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,

More information

Integrated AC Traction & DC Pump System Controller Model 1298

Integrated AC Traction & DC Pump System Controller Model 1298 Motor Controllers Integrated AC Traction & DC Pump System Controller Model 298 www.curtisinstruments.com Model 298 The Curtis Model 298 combines advanced control of AC induction traction motors with solid

More information

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Type MVTT 14 and MVTT 15: Static Digital Time delay relays Type MVTT 4 and MVTT 5: Static Digital Time delay relays Features 000/ setting range Time settings easily selected by means of thumbwheel switches Provide time delayed pick-up, or drop-off Compact construction

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE APPROVAL SHEET CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL 15V/2.0A SERIES NO. (M04) EA1030CU DATE 2013-04-01 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP D SIGNATURE:

More information

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment NTSA has developed the ultimate solution for protecting

More information

MCR 3. POWER EQUIPMENT MCR 3 I Constant Current Regulator. Microprocessor Controlled Constant Current Regulator. Compliance with Standards.

MCR 3. POWER EQUIPMENT MCR 3 I Constant Current Regulator. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. MCR 3 Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: AC 150/5345-10 (current edition), L-828, L-829. ICAO: Aerodrome Design Manual Part 5, para. 3.2 (current edition)

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 13W 3mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 3 ma output power 13 W Nominal life-time up to 5, h For luminaires

More information

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24 Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and

More information

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System Chloride FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System Chloride FP-60z The Chloride FP-60z is a true industrial UPS system offering a full-igbt innovative design and embedding all the latest technologies

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

ADAPTER SERIES SST-AD60-C

ADAPTER SERIES SST-AD60-C ADAPTER SERIES SST-AD60-C Compact, intelligent multi-voltage 60W USB Type-C adapter Maximum 60W 3A fast charging for USB Type-C equipped laptops, tablets, and mobile phones Intelligent detection and auto

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 69W 35-5mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 35 and 5 ma Max. output power

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 7W 5-35mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 5 and 35 ma Max. output power

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY. QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,

More information

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP Digital DC Drives The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from 1.5-600 HP The FlexPak 3000 digital DC drive features a unique ergonomic user interface

More information

Power Supply System for BTS Site

Power Supply System for BTS Site Power Supply System for BTS Site 48V300A extendable to 350A FnS Power Technology Inc. www.sacredsun.com, www.fnspower.com Page 1 of 7 48V300A(15KW) Power System Solutions and configurations 1 FS-Rectifier-48V50A

More information

Connect - Contact - Control. High Voltage Contactors. F 170e

Connect - Contact - Control. High Voltage Contactors. F 170e Connect - Contact - Control High Voltage Contactors F 170e 2 Contents Page 1.0. Application...3 2.0. Power Rating...3 3.0. Device Data...4 3.1. Electronic Contactor Type ZH 767E / 767F... 4 3.2. Contactor

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum) Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3

More information

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General

More information

Programmable Switching DC Power Supply

Programmable Switching DC Power Supply SS-C series (300W~900W,, with RS-232 interface) Introduction SS-C series are high accuracy programmable DC power supply with single output. MPU control, RS-232/RS- 485/USB interface for PC control, the

More information

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG.

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG. Alternative Energy Series and Field of Use LVD Series Low-Voltage Disconnect (LVD) stops battery damage due to over discharge by disconnecting the battery at an adjustable voltage. DCDC Series Regulated

More information

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU Battery charger Thyristor controlled with controller GMU Power plants Substations Rail and infrastructure Industry Battery charger Thyristor controlled with controller GMU Battery back-up DC-power supply

More information

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP) Discipline Engineering Standard - NSW Category Electrical Title s Reference Number PCP 07 - (RIC Standard: EP 99 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Product Specifications

Product Specifications Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin

More information

AC-DC Converter RECE K21

AC-DC Converter RECE K21 Thanks to the variety of modules available, the RECE3200-230-48-K21 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter

More information

Modular UPS S KVA

Modular UPS S KVA Scalable 3 - phase, double conversion UPS system with hot-plug design up to 220 KVA (n + 1). The modular design with 20 KVA modules makes any system up or downgrade flexible and avoids high inv estment

More information

DEB 575/1200. Electronic Flicker Free Ballast DMX MOD INSTRUCTION AND MAINTENANCE MANUAL

DEB 575/1200. Electronic Flicker Free Ballast DMX MOD INSTRUCTION AND MAINTENANCE MANUAL Pag. # 1 DEB 575/1200 Electronic Flicker Free Ballast DMX MOD. 2515.210 INSTRUCTION AND MAINTENANCE MANUAL Pag. # 2 INDEX Section 1 - DESCRIPTION Section 2 - OPERATION & ROUTINE MAINTENANCE Section 3 DISPLAY

More information

IST ULTRASTAB Power Supply for high precision transducers

IST ULTRASTAB Power Supply for high precision transducers IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see

More information

INSTRUCTION MANUAL MODELS: 1760A, 1761, Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays

INSTRUCTION MANUAL MODELS: 1760A, 1761, Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays INSTRUCTION MANUAL MODELS: 1760A, 1761, 1762 Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of

More information

RT9-48V/1.4kW Rectifier Specification

RT9-48V/1.4kW Rectifier Specification The RT9-48V/1.4kW is a switched mode rectifier (SMR) module that delivers up to 1.4kW of output power (and up to 30A output current) into a 48V nominal DC system. The RT9 suits AC supply voltages between

More information

User's Guide. Model W 3-in-1 Switching DC Power Supply

User's Guide. Model W 3-in-1 Switching DC Power Supply User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges

More information

Installation Manual for D24XX Series of 24V Switched Mode Power Supplies

Installation Manual for D24XX Series of 24V Switched Mode Power Supplies Installation Manual for D24XX Series of 24V Switched Mode Power Supplies Power Supply PCB only A Box B Box C Box 1 Amp general purpose D2401-P D2401-A D2401-B D2401-C 2 Amp general purpose D2402-P D2402-A

More information

THOR Battery Backed DC Power Supply Reference Manual

THOR Battery Backed DC Power Supply Reference Manual THOR Battery Backed DC Power Supply Reference Manual Revision A Firmware Compatibility: V1.03 P/N 60098001 Revised: 4/26/2012 INDUSTRIAL CONTROL LINKS, INC. 12840 Earhart Avenue Auburn, CA 95602 Tel: (800)

More information

DDR-120 series. 120W DIN Rail Type DC-DC Converter

DDR-120 series. 120W DIN Rail Type DC-DC Converter is a DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, : SPECIFICATION MODEL OUTPUT INPUT PROTECTION OTHERS NOTE DDR-120A-12 DDR-120A-24 DC VOLTAGE RATED CURRENT

More information

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIA Series Fully-Automated Multi-Function Electrical Safety Compliance Analyzers U.S. Patent Nos. (6,054,865, 6,011,398,

More information

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline

More information

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000. 7011A_JAN_2011_REVISED_88776_A_7011A 2/1/11 12:57 PM Page 1 7011A Series (6kVA to ) Advantages UNINTERRUPTIBLE POWER SUPPLIES Advanced IGBT technology in both the rectifier and inverter True double conversion

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence. 29-30 Brunel Road, Churchfields Industrial Estate, St. Leonards-on-Sea East Sussex. TN38 9RT. United Kingdom Sales & Service : 01424 853 013 All Other Departments : 01424 853 464 Fax : 01424 852 268 magnuspower.sales@akersolutions.com

More information

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc. IRM-5000P insulation resistance meter Vanguard Instruments Company, Inc. www.vanguard-instruments.com IRM-5000P insulation resistance meter The IRM-5000P is a microprocessor-based, high-voltage, insulation-test

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

RL Line/Load Reactors

RL Line/Load Reactors RL Line/Load Reactors Selection Table, Technical Details & Product Application Guide MTE HARMONIC COMPENSATED LINE/LOAD REACTORS help keep your equipment running longer by absorbing many of the power line

More information

AC-DC Converter REC /60-K20

AC-DC Converter REC /60-K20 Thanks to the variety of modules available, the REC3200-230-48-K20 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 2 auxiliary contacts (N/C),

More information

INSTALLATION & OPERATING MANUAL

INSTALLATION & OPERATING MANUAL INSTALLATION & OPERATING MANUAL IC 90 CHECK CONTENTS Package should contain.. Meter. Fixing Brackets (). Installation and Instruction Manual. The IC 90 meter is the latest kwh meter in the 900 series from

More information

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.111 Rev.4.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND CONNECTION BOARD 3

More information

Specification Voltage Limiting Device

Specification Voltage Limiting Device Engineering Specification Electrical Networks L1-CHE-SPE-152 Specification Voltage Limiting Device Version: 1 Issued: 20 th April 2018 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering,

More information

Dielectric Withstand and Ground Bond Testers

Dielectric Withstand and Ground Bond Testers Dielectric Withstand and Ground Bond Testers For Safety Agency Production Line Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The

More information