Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

Size: px
Start display at page:

Download "Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange"

Transcription

1 SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables Tools Optional AR-RB Digital Relay P P P P P P AR-RB AR-RB Digital Relay Installation A. B. Use a screwdriver to screw the mounting plate to the wall. Pull cables ends through the access hole in the mounting plate. Attach AR- (EF-V) or AR- (EV-V) to the mounting plate and install screws (supplied) into the holes at the bottom with the allen key. Apply power. LED (green) will light up with one beep. Notice.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing..wire selection: Use AWG - Shielded Twist Pair to avoid star wiring,cat cable for TCP/IP connection.power supply: Don t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the reader malfunction. The standard installation: Door relay and lock use the same power supply, and reader use independent power supply. Connector Table () Cable: P P P P P P P Wire Application Wire Color Description Lock Relay Blue White ()DCVAmp Purple White ()DCVAmp Lock Relay White ()DCVAmp Door Contact Orange Negative Trigger Input Exit Switch Purple Negative Trigger Input Alarm Relay Gray / Optional (by jumper) Power Thick Red DC Thick Black DC V Cable: P Wire Application Wire Color Description Beeper Pink Beeper Output V/mA, Low LED Yellow Red LED Output V/mA, Max Brown Green LED Output V/mA, Max Door Output Blue White Transistor Output Max. /ma (Open Collector Active Low) Wiegand Thin Green Wiegand DAT: Input Thin Blue Wiegand DAT: Input WG Door Contact Orange Negative Trigger Input WG Exit Switch Purple Negative Trigger Input Cable: P Wire Application Wire Color Description TCP/IP Output Orange White Net - TX+ Orange Net - TX- Green White Net - RX+ Green Net - RX Cable: P Wire Application Wire Color Description RS- for Lift Thick Green RS-(B-) Thick Blue RS-(A+)

2 Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange Yellow Description Cable: P Wire Application Power Security trigger signal Arming Duress Wire Color Red Purple Red White Yellow White Description DC Output Security trigger signal Output Arming Output Duress Output Front Panel & Indicator Power(Green) Alarm(Red) Alarm(Green) OK(Green) Error(Red) In processing(green). System will automatically exit from Programming Mode when inactivating for seconds.. LED status indicates controller s mode and status. OK (green) blinking constantly when operates in Programming Mode or flashing an existed card in card learn mode, it comes beeps warning and LCD panel displays Same Card: user address / card number Error (red) invalid card with beeps warning and LCD panel displays Card Number Err! or in anti-pass-back mode, when violates the access, it comes one beep warning and LCD panel displays Anti-pass Error! Arming (green) arming on status Alarm (red) any abnormal condition occurs. Keypad will be locked up sec. when constantly entering incorrect pin code or master code.. Maximum error in[ut of pin code and master code can be changed via the software Server (default: times) PWR / WED Duty : : 9 : OK PWR ERR : 9 : SE RI ES V SE RI ES V OK ERR PRE ARM PRE ARM WED Duty : Networking : / and interactively flash between the Month and DAY. [e.g.] / Stand-alone : No flashing [e.g.] / ( Reference to picture) Wiring Diagram Connect to Electric Bolt Electric Bolt E Connect to Magnet Lock Exit Switch DC Magnet Lock PB DC DC P P PB DC Copyright by SOYAL Technology Co., Ltd.. All rights reserved.

3 SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Connect to Electric Strike Connect to Door Contact Electric Strike PB DC P DC DC Door Contact ALM DC P CTL Alarm Relay Outpot Module Door Contact Strengthen security with AR-RB Connect to Reader Electric Bolt P DDR DC P CTL PB DC AR-RB Electric Bolt Reader E CTL BZ RLED GLED WG WG Exit Switch DC P BZ RLED GLED Door Output WG WG WG-DS WG-PB P Door Contact DC If any fire emergency, the people can escape by press a switch to open all doors Electric Strike DC Magnet Lock DC Electric Bolt E DC P PB Transistor IN PB P P PB Transistor IN Fire Emergency

4 Biometrics Device Access controller Fingerprint & Finger Vein V Programming A. Keyboard Lock/ Unlock Lock/ Unlock Press and, and at the same time to lock keyboard. Press again to unlock. B. Entering and Exiting Programming Mode Entering Input or PPPPPP [e.g.] The Default Value=. If already changed the Master Code=, input Access programming mode P.S.If entering no instruction within sec., it will automatically leave the programming mode. Exiting Press the repeatedly Quit or Quit and Arming (Please refer to alarm / arming setting) Changing the Master Code Access programming mode Tools Master Code Input the -digit new master code Succeeded C. Initial setup Language Setting Access programming mode Tools Language EN Succeeded Initial system... Node ID of Reader Setting Access programming mode Parameters[] Node ID Input New Node ID : ~ (default value:) Main Door Number : ~ WG Door Number : ~ Show UID (=No,=WG,=ABA,=HEX) Enable DHCP(:No,:En,=Exit) Succeeded D. Adding and Deleting Tag User capacity: (~) Tag Information CARD CODE SITE CODE CARD CODE SITE CODE Adding Tag by Tag ID Access programming mode Add/Delete Add -> Card ID Input -digit user address Input Site Code Input Card Code Adding Tag by RF Learn Function Access programming mode Add/Delete Add -> RF-Learn Input -digit user address Input Tag Units(pcs) Close Tag into RF Area If a batch of tags are Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with the lowest number to the controller. Suspend User Address Access programming mode Add/Delete Suspend -> Addr Input Start address Input End address Suspend Tag by Tag ID Access programming mode Add/Delete Suspend -> ID # Input Site Code Input Card Code Recover User Address Access programming mode Add/Delete Delete -> Addr Input Start address Input End address Recover Tag by Tag ID Access programming mode Add/Delete Delete -> ID # Input Site Code Input Card Code Deleteing User Address Access programming mode Add/Delete Delete -> Addr Input Start address Input End address Deleteing Tag by Tag ID Access programming mode Add/Delete Delete -> ID # Input Site Code Input Card Code Setting up the access mode Access programming mode User Setting Access Mode Input User Address : Invalid; : Card ; : Card or PIN; : Card & PIN E. PIN Code Access programming mode User Setting Password Input -digit user address Input -digit PIN (~9999) Succeeded Or via Client set it on Users screen

5 SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V F. Adding / Deleting Fingerprint or Finger-Vein Adding Access programming mode User Setting Enroll FP Key in -digit user address or different fingers on the sensor lens Succeeded P.S. The AR-EF need to collect twice for each fingerprint, and the AR-EV need to collect three times. Deleting Access programming mode User Setting Delete FP Key in -digit user address Succeeded P.S. If you want to delete all users FP, key in # G. Access Mode Access programming mode User Setting Access Mode Finger Identify Result Access Mode Hardware Client Hardware Client Key in -digit user address (~999) : Must :Invalid; :Card; : Card or PIN; : Card and PIN :Invalid Finger Identify: : Must ; : Ignore : Ignore Invalid User Succeeded H. Arming Password Access programming mode Parameters[] Arming PWD Input -digit PIN (~9999; Default: ) Succeeded Or via Server and set it on AR-9E screen I. Arming Delay Time Access programming mode Parameters[] ArmingDelayTm Enter armed sta. Delay time(sec),range:~; Armed pulse out-put time. (ms),range:~ Succeeded J. Duress Code Access programming mode Parameters[] Duress Code sets (select one) Input -digit PIN (~9999) Succeeded Or via Server to set it on AR-9E-V screen Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a warning signal. K. Terminal Port Access programming mode Tools Terminal Port :Lift ; :Host ; :LED ; :PRN (default value:) Baud Selection (default value:9) Succeeded L. Setting up the alarm / arming Conditions:. Arming enabled.alarm system connected Application:. Door open too long: Door is open longer than door relay time plus door close time.. Force open (Opened without a valid user card): Access by force or illegal procedure.. Door position abnormal: When power is off and then on, reader on arming before power off. Enable/Disable the arming status: Standby Mode Card only Card or PIN Card and PIN Open the door Present the tag to reader Input digits arming PWD Access Programming mode Enable: Access programming mode [Use FP] can substitute for [Induct valid card]. :Card :Card or PIN :Card and PIN No open the door Input digits arming PWD Present the tag to reader : Must : Ignore : Must : Ignore : Must : Ignore Input user address Input digits individual PWD Input digits arming PWD Quit & Arming Disable: Access programming mode Quit Finger+Card. Card Only. Finger Only. Finger+Card. Finger+PIN. Card+Finger+PIN. Card+Finger+Card. PIN+Finger+PIN. PIN+Finger+Card. Card Only. PIN Only. Finger Only Finger+Card+PIN. Card+PIN. Finger+PIN Present the tag to reader Input digits individual PWD Input digits arming PWD

6 Biometrics Device Access controller Fingerprint & Finger Vein V M. Anti-pass-back While connect with AR-U, AR-H/U(WG mode) and AR-U for anti-pass-back function, the access mode needs to be "Card" only. Device enable Access programming mode Parameters[] Anti-pass-back master controller select [: Yes] WG select [: Yes] Card user enable Access programming mode Add/ Delete 9 Antipass Group Input -digit starting user address Input -digit ending user address must select [: Yes] N. Lift control [e.g.] Connect with AR-ROB to control which floors the user will be able to access. (BAUD9) Setting Lift control Access programming mode Tools Terminal Port :Lift Baud Selection : 9 Access programming mode Tools Terminal Port :Lift (need to use L) Set Floor/ Stop 9 9 Single floor Access programming mode User Setting Single Floor Input -digit user address Input single floor number: ~ Multi floors Access programming mode User Setting Multi Floor Input -digit user address Select range: or or or Input digits multi floors number [:disable, : enable] [e.g.] Set NO., can use it with the F and F: Access programming mode User Setting Multi Floor O. Alarm Clock (for Factory) Access programming mode Tools 9 Daily Alarm Set (~) Set Start Tm ( Hours) ; Set Effect Sec. (Seconds as the bell time, Range:~) Set Weekday (:disable, : enable) Succeeded Hardware installation Horn Music Box Board Mike device Mike device DC DC Relay Board CTL Mike's sound wire Mike's sound wire M M Music Box Output to M and M P ALM P. OpenZone Access programming mode Parameters[] OnOff OpenZone Main Auto Open Zone (:disable,:enable) Open Door Imm. During Open Zone (:No,:Yes) WG Port Auto Open Zone (:disable,:enable) Open Door Imm. During Open Zone (:No,:Yes) Succeeded Q. Open TimeZone Access programming mode Tools Open TimeZone Set (~) Time ( Hours) ; Main Port (:disable, : enable) ; WG Port (:disable, : enable) Weekday (:disable, : enable) succeeded

7 SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Firmware Upgrade Get the upgrade software from SOYAL or our distributor and run UdpUpdater software Execute the software The software is within SOYAL CD or Login the SOYAL web to downloads Update the firmware [Please login the SOYAL web to download the new ISP Firmware.]. Input the Target Address and Port. [Load F/W] open the documents that have the new ISP Firmware. Click the new ISP Firmware and [Open] it. Click [Update F/W] to start the firmware update. Till the screen shown [Firmware Update is Complete] Restoring Factory Settings Reset all device parameters and user card data Reset all device parameters and user card data: Access programming mode Parameters 9 Factory Reset : System Param ; : User Setting ; : System & User Reset IP Setting: When the device's power is on, press the RESET button the main board untill the ERR (Red) LED of screen lights up. (Reference to picture) After operation as above, you will hear the long reminder sound,and wait until the sound disappear then reset the power of the controller,the device will restore factory setting. After done the "Factory Reset", the External Communication Port must be reset. Or the biometric sensor won't be functional. Tools Ext. Comm Port (:FP- ; :Lift ; :Vein ; :FP-9 ; :Reserved ) RESET Manu Tree. Add/ Delete. Add > Card ID. Add > RF Learn. Suspend > Address. Suspend > ID #. Delete > Address. Delete > ID #. Recover > Address. Recover > ID # 9. Antipass Group. User Setting. Password. Access Mode. Extend Options. Single Floor. Multi Floor. Enroll Finger. Delete Finger. Parameters[]. Node ID. OnOff OpenZone. Door Relay Tm. Door Close Tm. Alarm Relay Tm. Alarm Delay Tm. Arming Delay Tm. Arming PWD. Parameters[]. Auto Relock. Egress(R.T.E). Miscellaneous. Force Open. Close & Stop. Anti-pass-back. Duress Code. Password Mode 9. Factory Reset. Tools. Language. Master Code. Master Range. Terminal Port. Ext.Comm Port. Open Time Zone. Informations. Clock Setting 9. Daily Alarm. Quit. Quit & Arming

8 Biometrics Device Access controller Fingerprint & Finger Vein V IP Setting Open your Web Browser and input factory default IP address: If the IP address of AR- (EF/EV-V) has changed We must enter the new IP address. Page menu Monitor the on-line computer IP Setting Change the Log-in information Current State Online Status is able to monitor and show which computer is linking on Ethernet Module Show which computer is linking on Ethernet Module. Current IP address of the AR- (EF/EV-V) Log-in User Password When you choose the "Networking Setting" or "User Password" at first. Log-in window will pop out and please input At the Factory Default User name: admin Password: No as default value,so please just press OK to log-in admin Networking Setting You will find initial IP Address 9... and check MAC Address is the same as sticker on Ethernet Module device. Please revise IP address you want, and then click Update button. After updating the IP, please re-connect the Web Browser by new IP address. User Password Change the log-in password to lock the IP setting of Ethernet Module. The password composes of characters at most, it can be either A~Z or ~9.

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide

More information

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function.

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function. SOYAL ACCESS CONTROL SYSTEM AR- (EF) V00 Contents Product User Guide Terminal Cables Tools Optional P P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 WG keyboard AR-(EF-DO) Installation

More information

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P

More information

SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X)

SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X) SOYAL ACCESS CONTROL SYSTEM AR- (E-V) V0 Contents AR- (E-V-M) Products User Guide Terminal Cables Tools P P P c x d x A. B. C. D. P P P P AR- (E-V) Products User Guide Terminal Cables Tools P P P e x A.

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

SOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools

SOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Contents Product Terminal Cables Tools Accessories Option P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 AR-(E) AR-(EF) P P P Security Torx Wrenches

More information

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H) AR- (H) / AR- (H)/ AR-(H) / AR- (H) / AR- (H) SOYAL ACCESS CONTROL SYSTEM V0 Contents AR- (H):Touch-panel Metal Housing Product User Guide Terminal Cables Tools Water proof Strip d x P P P P AR- (H):Touch-panel

More information

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter SOYAL AR-H/AR-H/ AR-H/AR-H/AR-H ACCESS CONTROL SYSTEM Contents AR-H [Touch-panel Metal Housing] Product User Guide Terminal Cables Water proof Strip d x AR-H [Touch-panel Metal Housing]/ AR-H-S [Metal

More information

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C.

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C. EC-ACC90IP-/P Contents EC-ACC90IP- Products User Guide Terminal Cables Tools P P P a x A. E. F. P P P P EC-ACC90IP-P Products User Guide Terminal Cables Tools P P P b x A. B. C. D. P P P P c x Parts Description

More information

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M SOYAL AR-H/AR-H/ AR-H/ ACCESS CONTROL SYSTEM Contents AR-H [Metal Case] Product Water proof Strip d x AR-H Product f x AR-H [Illuminated Touch-panel] AR-H-M Products c x e x A. B. C. D. AR-H Products f

More information

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.

More information

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption SOYAL ACCESS CTROL SYSTEM AR-E V0 Contents Product User Guide Panel Mounting Base WG Key-panel Reader Option AR-0B-X Fit mm DIN Rail or Mount directly AR-K AR-K AR-K Option For Stand-alone Command Setting

More information

AR-727H. Technical Manual. 26 August Version 1.00

AR-727H. Technical Manual. 26 August Version 1.00 AR-727H Technical Manual 26 August 2008 Version 1.00 Southern Office: Raytel House Brook Road Rayleigh Essex, SS6 7XH Tel: (01268) 749310 Fax: (01268) 749315 Northern Office: Unit 3 Block 5 Oakbank Industrial

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

Fingerprint Identification Proximity Reader. Quick Installation Guide

Fingerprint Identification Proximity Reader. Quick Installation Guide Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor

More information

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

Operation manual For NG BIOSINGLE Version 1.1

Operation manual For NG BIOSINGLE Version 1.1 Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0 Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01 Comfort, the Intelligent Home System Comfort Fingerprint Reader Interface FPR01 Introduction to the Comfort Fingerprint Reader Interface... 1 Specifications... 2 Equipment... 2 Settings... 2 Connections...

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web: ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

BioPointe Reader Installation Guide

BioPointe Reader Installation Guide BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

T9 Fingerprint Machine Hardware User Manual. Date: Version: 1.1

T9 Fingerprint Machine Hardware User Manual. Date: Version: 1.1 T9 Fingerprint Machine Hardware User Manual Date: 2010.07.27 Version: 1.1 (c)2010 Copyright Pegasus Equipments Ltd. All Rights Reserved. 1 Table of Content Introduction... 3 Installation... 3 Menu Structure...

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights

More information

Installation & User Manual V2.08

Installation & User Manual V2.08 YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x

More information

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Set-up of ZK RFID Pin Pad

Set-up of ZK RFID Pin Pad Set-up of ZK RFID Pin Pad Version 0. 1 Prepared by: Shaun Laas Softcon Software Control Services (Pty) Ltd. 7 March 2017 Revision History Name Date Reason For Changes Version SL SL 26-Jan- 2016 26-Jan-

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

GV-Card Reader. User s Manual

GV-Card Reader. User s Manual GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights

More information

VIDI-AC-2CS Access Controller/ Reader

VIDI-AC-2CS Access Controller/ Reader VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS

More information

PR602LCD v1.0 Installer Manual Rev. A

PR602LCD v1.0 Installer Manual Rev. A PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide H2i s u p p o r t @ f i n g e r t e c. c o m H2i Simple Fingerprint Door Access & Time Attendance System User Guide CONTENTS 3-4 Chapter 1 getting started Viewing the User Guide in the Internet Included

More information

GV-RK1352 and GV-R1352 Card Reader

GV-RK1352 and GV-R1352 Card Reader GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

BC Digital Keypad. User Manual

BC Digital Keypad. User Manual BC2200 Digital Keypad User Manual Name Digital Keypad BC2200 User manual Screw driver Rubber bungs Self tapping screws Diode 1. Packing List Quantity Remarks 1 1 1 4 Φ6mm 28 mm, used for fixing 4 Φ4mm

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

GENERAL QUICK START GUIDE

GENERAL QUICK START GUIDE GENERAL QUICK START GUIDE 2.8InchPalm & Fingerprint Time Attendance & Access Terminal Version: 1.0 Date: May., 2017 Note: The picture and function presented in this manual are only for reference. The following

More information

Fingerprint Door Lock User MANUAL

Fingerprint Door Lock User MANUAL Fingerprint Door Lock User MANUAL Notes: Please read this manual carefully before operation. 0 User Manual AKME LOCK LLC Contents CHAPTER 1: INTRODUCTION... 2 1.1 FEATURES... 2 1.2 TECHNICAL SPECIFICATION...

More information

A-1300 Biometric Access Control System USER'S MANUAL

A-1300 Biometric Access Control System USER'S MANUAL A-1300 Biometric Access Control System USER'S MANUAL Table of Contents 1. General Information... 1 1.0 Notification... 2 1.1 System Overview... 2 1.2 Main Features... 2 1.3 Equipment... 3 2. Basic Concepts...

More information

T-7 FINGERPRINT TERMINAL. HARDWARE USER'S MANUAL Rev 1.1

T-7 FINGERPRINT TERMINAL. HARDWARE USER'S MANUAL Rev 1.1 T-7 FINGERPRINT TERMINAL HARDWARE USER'S MANUAL Rev 1.1 1 Table of Contents 1. INTRODUCTION 1.1 SUPPLIED PART LIST 1.2 ABOUT PEGASUS T-7 1.3 HARDWARE SPECIFICATION 2. PRODUCT OVERVIEW 2.1 COMMUNICATION

More information

FINGERPRINT TERMINAL HARDWARE USER'S MANUAL

FINGERPRINT TERMINAL HARDWARE USER'S MANUAL http://www.epordo.com 1 FINGERPRINT TERMINAL HARDWARE USER'S MANUAL or email us at info@securiticn.com 1 1. INTRODUCTION 1.1 SUPPLIED PART LIST 1.2 ABOUT 1.3 HARDWARE SPECIFICATION 2. PRODUCT OVERVIEW

More information

Specifications: Features:

Specifications: Features: ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection

More information

Fingerprint Door Lock OPERATOR S MANUAL

Fingerprint Door Lock OPERATOR S MANUAL Fingerprint Door Lock OPERATOR S MANUAL Notes: Please read this manual carefully before operation. 1 Contents Chapter 1: Introduction 03 1.1 Features 03 1.2 Technical Specification 03 1.3 Fingerprint recognition

More information

CV-945 Stand-Alone Biometric Reader. Installation Instructions

CV-945 Stand-Alone Biometric Reader. Installation Instructions CV-945 Stand-Alone Biometric Reader Installation Instructions Contents 1.0 Introduction... 03 2.0 Mounting... 03 3.0 Specifications... 04 4.0 Application Diagram... 04 5.0 Wiring... 05 6.0 Recommended

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT

More information

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.

More information

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration

More information

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed F18 Features: 1. 2.4 TFT LCD color screen 2. Standard Wiegand Input and Output interfaces are compatible with most all 3 rd party 26 bit Wiegand readers and access control panels. 3. USB HOST port makes

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

QUICK START GUIDE FOR SC 403

QUICK START GUIDE FOR SC 403 QUICK START GUIDE FOR SC 403 Items included when your package arrives; RFID Card for SC 403 Screwdriver Tool Quick start Guide Important Notes Do not place the SC 403outdoors without adequate protection

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

Installation Instructions (KF-2000)

Installation Instructions (KF-2000) VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809

More information

HSY-S209 EM Metal waterproof access control system User Manual

HSY-S209 EM Metal waterproof access control system User Manual HSY-S209 EM Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1. Product Profile The product is Contact-less inductive card Metal Password Access Controller,

More information

CC Series metal access control Manual

CC Series metal access control Manual CC Series metal access control Manual 1.Description CC Series is a standalone for two doors, support card, pin, card+pin access way. It is with 2 relays to control 2 doors and supports up to 2000 users

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information