1 CETAC ASX-520 Family SpeedShift Utility Upgrade Kit Installation Guide Manual Part Number Rev 3a

2 COPYRIGHT CETAC Technologies Rev 3a, February, 2011 CETAC Technologies authorizes its customers to reproduce, transmit, or store this document in its entirety, including this page, for the express purpose of installing, operating, or maintaining the product described herein. CETAC Technologies Customer Service & Support Industrial Road Omaha, Nebraska 68144, USA Phone (800) (USA only) Phone (402) Fax (402) REVISIONS CETAC Technologies strives to provide the scientific community with an unparalleled combination of effective technology and continuing value. Modular upgrades for existing instruments will continue to be a prime consideration as designs progress. CETAC Technologies reserves the right to revise this document and/or improve products described herein at any time without notice or obligation. Warranty registration entitles the named owner exclusively to manual change pages/new editions as they are published. TRADEMARK ACKNOWLEDGEMENTS Windows is a registered trademark of Microsoft Corporation in the United States and other countries. All other marks are the property of their respective owners.

3 Contents 1 Introduction... 5 Overview... 5 Improved Productivity... 5 Improved Economy... 5 Improved Carryover Control... 5 Improved Cross-Contamination Control... 5 Getting Started... 5 System Requirements... 6 Supported Autosampler Personalities... 6 Supported Firmware Versions Upgrading the Autosampler Firmware... 9 Upgrading Firmware to an Existing Processor Module... 9 Where to Get the Firmware... 9 Preparing the Autosampler for Firmware Upgrade Establishing Communications Loading the Firmware Configuring the Autosampler for Programming Upgrading the Firmware Returning the Autosampler to its Normal Configuration Verifying the Firmware Upgrade Upgrading Firmware by Installing a New Processor Module Accessing the Interior of the Autosampler Processor Module Installation (ASX-520) Processor Module Installation (ASX-260) Configuring the Autosampler Personality Setting the Pump Speed Jumper Setting the Pump Speed Jumper (ASX-520/ASX-520HS/EXR-8) Setting the Pump Speed Jumper (ASX-260) Closing Up the Autosampler Installing the Utility Using the Utility Running the utility Viewing the Current Settings Changing a Setting Explanation of the Settings Pump Timeout Pump Speed Level X/Y Axis Travel Speed Z Axis Travel Speed

4 Explanation of the Controls Initialize Communications Set 50 Factory Reset Test XYZ Speed Toggle Pump Determining the Best Travel Speed for Your Application Operating a CETAC Autosampler Using a Terminal Program Using C-Term Starting C-Term Overview of the C-Term Window Configuring C-Term Setting Preferences Using HyperTerminal Autosampler Commands

5 1 Introduction Overview The ASX-520 SpeedShift utility lets you control autosampler settings such as rinse pump timeout, rinse pump speed and axis speed. Improved Productivity The utility can shorten run times by increasing the speed of movement along the X-, Y-, and Z-axes. Improved Economy The utility can reduce consumption of the rinse solution by slowing the rinse pump speed. The rinse pump timeout eliminates rinse solution waste at the end of a sample run especially for instruments which return the probe to the rinse station without turning off the pump. Improved Carryover Control The utility can address carryover concerns by increasing the rinse pump speed to improve probe cleaning effectiveness at the rinse station. Improved Cross-Contamination Control The utility can reduce the speed of axis movement to reduce the potential for droplet shedding, which can cause sample-to-sample carryover. Getting Started To use the utility, you will need to 1 Upgrade the autosampler firmware. Information on the required firmware version is on page 6. You can upgrade firmware by downloading it from a PC (see page 9), or by installing a new processor module which has the firmware pre-loaded (see page 23). 5

6 2 Set the autosampler pump speed jumper to its fastest setting (see page 37). 3 Install the utility on the PC which controls the autosampler (see page 41). 4 Run the utility and change the settings (see page 47). System Requirements Every autosampler has a personality and a firmware version. To determine the personality and firmware version of your autosampler, use the VER command as described in the chapter "Operating a CETAC Autosampler Using a Terminal Program" beginning on page 51. Supported Autosampler Personalities The utility is compatible with CETAC ASX-520, EXR-8, and ASX-260 autosamplers with the following personalities: CETAC Standard 520 (includes many OEM models including Thermo, Spectro and Varian/Agilent*) CETAC Standard 520 High-Speed (includes many OEM models including Thermo and Spectro) CETAC Standard 260 (includes many OEM models including Thermo, PerkinElmer, and Spectro) CETAC EXR-8 (Standard and High-Speed) Perkin Elmer 520 (Standard and High-Speed) Perkin Elmer EXR-8 (Standard and High-Speed) Perkin Elmer 260 Speedy HP/Agilent 520 Micromass 520 Thermo AA 520 Finnegan Mat 520 Foss 260 Lachat 520 Lachat ASX-260 * Agilent acquired Varian in The CETAC Standard 520 personality applies to Varian version ASX-520 autosamplers, and to their Agilent equivalents. If you have any questions regarding how to identify your current autosampler personality setting, please contact CETAC Technologies at Supported Firmware Versions Autosamplers manufactured after March, 2011 do not need to be upgraded to use this utility. The utility is compatible with the following firmware versions: Firmware version 1.14 This version is the minimum requirement, and will allow the user to operate the pump timeout feature only. No axis or pump speed settings are available. Firmware version 1.16 Supports all features of the ASX-520 SpeedShift utility. 6

7 Chapter 1: Introduction See the next chapter for information on obtaining and upgrading the firmware. You can upgrade the firmware by setting some switches and using a firmware update utility, or by replacing the processor module in the autosampler. Contact CETAC to determine which method is most appropriate for your autosampler. If you have any questions, concerns, or need help upgrading your firmware to be able to take full advantage of the features offered by this utility, please contact CETAC Technologies at 7

8 This page is intentionally blank. 8

9 2 Upgrading the Autosampler Firmware If your autosampler does not have one of the supported firmware versions, but it does have a processor module which allows firmware to be updated, follow the instructions in this chapter to update the firmware. If the processor module does not allow firmware updates, see "Upgrading Firmware by Installing a New Processor Module" on page 23. Contact CETAC to determine which method is most appropriate for your autosampler. This chapter summarizes the instructions from the Guide to Upgrading the Firmware in a Cetac ASX-520/520HS Autosampler, supplied on the software CD. To update the firmware, you will need to disassemble the autosampler so that you can set some DIP switches. WARNING ELECTRICAL AND MECHANICAL HAZARDS Make sure the unit is off and unplugged before beginning this procedure. Upgrading Firmware to an Existing Processor Module Where to Get the Firmware The software needed to upgrade the firmware on the autosampler and the firmware upgrade file can be downloaded from the CETAC web site. To download the software and the firmware, go to and select Autosampler Firmware Update. You will be presented with a form that asks for basic contact information. Upon completion, you will be ed a web site address, a login ID and a password that will allow you to download any new 9

10 firmware upgrade that may be available for your autosampler along with the necessary software to perform the upgrade. Preparing the Autosampler for Firmware Upgrade Figure 2-1 Front view of ASX First, remove the two Kynar thumbscrews from the Y-axis home block. Figure 2-2 View of Y- axis home block with Kynar thumbscrews. 10

11 Chapter 2: Upgrading the Autosampler Firmware Figure 2-3 Z-drive removed from arm assembly. 2 Next, remove the whole Z-drive assembly from the arm by pulling the whole Z- drive assembly forward and off the autosampler arm. See Figure After the Z-drive assembly is removed, then remove the rinse station. See Figure 2-4. Turn the rinse station ¼ turn counter-clockwise while pulling up. Also, the tubing located at the bottom of rinse station will have to be removed or moved aside. See Figure 2-5. Figure 2-4 View of rinse station. Some autosamplers may have a different rinse station, although they both connect the same. 11

12 Figure 2-5 View of rinse stations removed from the front cover. 4 The autosampler tray is next to be removed. Lift up on the tray and pull forward. 12

13 Chapter 2: Upgrading the Autosampler Firmware Figure 2-6 Removing the tray. Figure 2-7 Front view of ASX-520 autosampler showing front cover screws 5 Next, the front cover needs to be removed. Remove the four corner screws shown in Figure The front cover can be removed by lifting it slightly and pulling forward. 13

14 Figure 2-8 View of ASX-520 autosampler with the front cover being removed Figure 2-9 View of inner shield inside the ASX-520 (old shield) 7 The five screws that hold the inner shield will have to be removed. Move the Y-axis assembly all the way to the left. See Figure 2-9. If you have a newer two piece shield and splashguard proceed to step 9. 8 The inner shield can be removed by moving the arm to the right or left then lifting it up while pulling forward. 14

15 Chapter 2: Upgrading the Autosampler Firmware Figure 2-10 Removal of inner shield. Figure 2-11 View of ASX-520 with inner shield removed (Rev 5 main board). 15

16 Figure 2-12 View of older style main board (Rev2). 9 If you have a newer shield/splash guard combination proceed as follows. Locate and remove the 5 screws holding the shield in place. Figure 2-13 View of new shield and splashguard inside the ASX Remove the two shield pieces. Notice that the splashguard goes under the chassis on the top and over the chassis on the bottom. When you replace the splashguard, ensure it is oriented in this manner. 16

17 Chapter 2: Upgrading the Autosampler Firmware Figure 2-14 View of splashguard placement. 11 Remove the splashguard by pulling it out from one side. It may be necessary to reach under the guard and remove it from the support standoffs. 17

18 Figure 2-15 View of splashguard removal. Establishing Communications This procedure assumes that you have previously established a serial connection to the autosampler, as described in the autosampler Operator's Manual. 1 Put the Z-drive assembly back on the arm and screw in the Y-axis home block. 2 Reconnect the power cord and the serial cable and turn the autosampler on. 3 Start a terminal program. (For instructions, see Operating a CETAC Autosampler Using a Terminal Program" beginning on page 51".) 4 Ttype VER. The system will respond with the current firmware version and it should be noted. 5 Type HOME. This is to verify that the system is communicating. 6 Close the terminal program. 18

19 Chapter 2: Upgrading the Autosampler Firmware Loading the Firmware The firmware is loaded into the autosampler by a small utility application called the Rabbit Field Utility. (The name comes from the Rabbit-branded single-board computer in the autosampler.) 1 Find the firmware directory on the CD. 2 Run the Rabbit Field Utility application, RFU.exe. 3 On the Setup menu, click Communications. 4 Select the COM port on the computer that is connected to the autosampler, then click OK. 19

20 5 On the Setup menu, click File Locations. 6 In the Choose File Locations window, fill in the fields with Cold Loader as coldload.bin and Pilot BIOS as pilot.bin, then click OK. 20

21 Chapter 2: Upgrading the Autosampler Firmware Configuring the Autosampler for Programming 1 Turn off the autosampler. 2 On the main board move the jumpers from J3 & JP4 to J5 & JP6. Rev 2, Normal Operation Rev 2, Programming Rev 5, Normal Operation Rev 5, Programming Figure 2-16 Jumpers on Rev 2 and Rev 5 boards. 3 Turn the autosampler back on. Upgrading the Firmware 1 On the File menu, click Load Flash Image. 21

22 2 In the Choose Flash Image window, select the firmware file. For the ASX-520 HS autosampler, choose ASX_HS_V1_18.bin. For all other autosamplers, choose ASX_V1_20.bin. (Of course, if you have a more recent version of the firmware, you can use that.) 3 Click OK. A progress bar will appear. 4 When the upgrade is complete, the Rabbit Field Utility can be closed. Returning the Autosampler to its Normal Configuration 1 Turn off the autosampler. 2 On the board move the jumpers from J5 & JP6 back to J3 & JP4 (Figure 2-16). 3 Turn the autosampler back on. The autosampler should go to the home position. 22

23 Chapter 2: Upgrading the Autosampler Firmware Verifying the Firmware Upgrade 1 Start a terminal program as described beginning on page Enter the VER or VERSS command. The system should respond with the new firmware version. 3 Turn off the autosampler. 4 Remove the Z-drive assembly from the y-arm. 5 Install the splash guard, if equipped, taking note of the top and bottom edge placement as noted earlier. 6 Install the inner shield. 7 Replace cover and rinse station. 8 Replace z-drive assembly. 9 Reconnect the power cord and turn on the power switch. Upgrading Firmware by Installing a New Processor Module In some cases, it may be necessary to install a new processor module, sometimes called a "Rabbit module." Most of the steps apply to the ASX-260, EXR-8, ASX-520 and ASX-520HS autosamplers. In some places, the steps are different for the ASX-260. NOTE Your equipment may differ in appearance from what is shown in the photos. The photos show components which are intended to represent typical CETAC instruments from a range of eras. Accessing the Interior of the Autosampler 1 Place the autosampler on a flat surface and ensure that the unit is powered off. 23

24 Figure 2-17 Front view of ASX-520 Autosampler. Figure 2-18 Front view of ASX-260 Autosampler. 2 Remove the two Kynar thumbscrews from the Y-axis home block (Figure 2-19). 24

25 Chapter 2: Upgrading the Autosampler Firmware Figure 2-19 View of Y-axis home block with Kynar thumbscrews (ASX-260 and ASX-520). 25

26 3 Remove the entire Z-drive assembly from the Y-arm by pulling the Z-drive assembly forward and off of the autosampler arm as shown (Figure 2-20 and Figure 2-21). Figure 2-20 Z-drive removed from arm assembly (ASX-520). Figure 2-21 Z-drive removed from arm assembly (ASX-260). 26

27 Chapter 2: Upgrading the Autosampler Firmware 4 Once the Z-drive assembly is removed, remove the rinse station (Figure 2-22/Figure 2-23). Turn the rinse station ¼ turn counter-clockwise while pulling it upward. Also, the tubing located at the bottom of rinse station will have to be disconnected from the pump at the rear of the autosampler. Figure 2-22 View of rinse station (ASX-260 and ASX-520) Figure 2-23 View of rinse station removed from the front cover (ASX-260) 27

28 5 The autosampler tray should then be removed. Lift up the tray and pull out (Figure 2-24). Figure 2-24 Removing the tray (ASX-520) 28

29 Chapter 2: Upgrading the Autosampler Firmware 6 Next, the front cover is to be removed. Remove the four corner screws (Figure 2-25/Figure 2-26). Figure 2-25 Front view of ASX-520 Autosampler showing front cover screws Figure 2-26 screws Front view of ASX-260 Autosampler showing front cover 29

30 7 The front cover is removed by lifting it slightly and pulling forward (Figure 2-27/Figure 2-28). Figure 2-27 View of ASX-520 Autosampler with the front cover being removed Figure 2-28 removed View of ASX-260 Autosampler with the front cover being 30

31 Chapter 2: Upgrading the Autosampler Firmware 8 The screws that hold the inner shield must be removed. Move the Y-axis assembly all the way to the left (Figure 2-29/ Figure 2-30 shows screw locations). Your autosampler may have a newer style shield with splashguard. These are removed in a similar manner. Figure 2-29 View of inner shield inside the ASX-520 Autosampler Figure 2-30 View of inner shield inside the ASX-260 Autosampler 31

32 9 The inner shield can be removed by lifting it up while pulling forward (Figure 2-31/Figure 2-32). Figure 2-31 Removal of inner shield (ASX-520) Figure 2-32 Removal of inner shield (ASX-260) 32

33 Chapter 2: Upgrading the Autosampler Firmware Processor Module Installation (ASX-520) These instructions for installing the processor module apply to the ASX-520 and similar autosamplers. See page 34 for instructions for ASX-260 autosamplers. 1 Find the processor module on the main board and note its orientation (Figure 2-33). Processor module Figure 2-33 Processor module location on main board (ASX-520/ASX- 520HS) 2 Remove the existing processor module from the main board (Figure 2-33) by pulling straight upward and firmly on the processor module, gripping it by the sides. Do not use any tools to remove the module, as damage to the module and/or main board WILL result. CAUTION EQUIPMENT DAMAGE Do not use any tools to remove the module. 33

34 3 Insert the new processor module (supplied in the upgrade kit) in the same position/orientation as the removed unit had been installed. Be sure to align all pins to the proper socket hole location, using care to insert the module fully and securely. Figure 2-34 Processor Module shown removed and placed to show pin orientation (ASX-520/ASX-520HS) CAUTION When inserting or reinserting any connectors, such as the ribbon cable, auxiliary board or processor module, make certain that they are properly connected, ensuring that no pins are bent and all the pins are in their proper position in the connector. Improper connections could result in damage to the main board or other components. Processor Module Installation (ASX-260) 1 Remove the existing processor module from the main board (Figure 2-35) by pulling straight outward and firmly on the processor module, gripping it by the sides. Do not use any tools to remove the module, as damage to the module and/or main board WILL result. See Figure 2-36 for photo of the processor module removed from main board. 2 Insert the replacement module processor (supplied in the upgrade kit) in the same position/orientation as the removed unit had been installed (Figure 2-35). Align all pins to the proper socket hole location, using care to insert the processor module fully and securely. 34

35 Chapter 2: Upgrading the Autosampler Firmware Processor Module Figure 2-35 Processor module location on main board (ASX-260). Figure 2-36 Main board shown with processor module removed Note: Do not replace the cover/shields/z-drive assembly yet. You still need to increase the pump speed, as described in the next chapter. 35

36 Configuring the Autosampler Personality Several different configurations, or personalities, are built into the autosampler firmware. When you replace the processor module, this personality may need to be set. 1 Connect a terminal emulation to the autosampler. The autosampler can be controlled using a serial communications protocol. See Operating a CETAC Autosampler Using a Terminal Program on page 51. You can use any terminal emulation program, including: C-Term. (recommended) This program provided is on the software CD, and runs on Windows 2000 and later. HyperTerminal. This program was supplied with versions of the Windows operating system through Windows XP. 2 Enter the command VER 3 The information returned will include the personality description. 4 If the personality shown is not appropriate for your autosampler, contact CETAC to obtain the correct "SETTYPE" personality number. 5 Enter the command SETTYPE=nnn where nnn is the personality number. 6 Cycle power on the autosampler. 7 Verify the personality with the VER command. To reset the firmware to the ASX-520 Standard configuration, two "~" characters in succession should be sent. The system will respond with an "OK:". 36

37 3 Setting the Pump Speed Jumper The ASX-520 SpeedShift utility can control the peristaltic pump speed. But the pump speed can also be controlled by moving a jumper on the autosampler's circuit board. The utility assumes that the jumper is set to the highest speed. Therefore, it may be necessary to move the jumper. What happens if the jumper is not set to the highest speed? The speed of the pump will be less than the speed set by the ASX-520 SpeedShift utility. At lower speed settings, the pump might not run at all because the voltage being applied to the pump is insufficient for it to overcome friction. Setting the Pump Speed Jumper (ASX-520/ASX- 520HS/EXR-8) 1 Locate the block of pump speed pins on the left side of the ASX-520/ASX-520HS main circuit board 2 Move the jumper from its existing position to the position marked Max RPM (Figure 3-1). 37

38 Figure 3-1 Jumper position utilized to increase pump speed (ASX-520) Note: ASX-520/ASX520HS main boards of differing eras/versions may have varying orientation of jumper positions. Follow the label on the circuit board for proper jumper positioning. Setting the Pump Speed Jumper (ASX-260) 1 Locate the block of pump speed pins, labeled JP8, on the left side the centerleft of the ASX-260 board. Figure 3-2 Location of pump speed jumpers (ASX-260) 2 Move the jumper to the bottom position. 38

39 Chapter 3: Setting the Pump Speed Jumper Figure 3-3 Jumper shown in the correct position (ASX-260) Closing Up the Autosampler Once the firmware has been upgraded and the pump speed has been set, you can close up the autosampler. Reinstall all shields Reinstall the front cover Reinstall the Z-drive assembly 39

40 This page is intentionally blank. 40

41 4 Installing the Utility These instructions show installation on a Windows XP system. Other operating systems may display additional prompts. 1 Insert the supplied CD. The installation software will autorun when the disc is loaded into the CD- ROM drive of the host computer. If the CD does not autorun, or if the software was downloaded, use Windows Explorer to open the location containing the software, then select Setup Launcher (Figure 4-1) to begin the software installation. Figure 4-1 Setup Launcher Follow the prompts of the Installation Wizard to complete the installation of the utility. 41

42 2 When the Installation Wizard window opens, click Next to begin the software installation process ( Figure 4-2). Figure 4-2 Installation Wizard 3 Reviewing the summary information, then click Next (Figure 4-3). 42

43 Chapter 4: Installing the Utility Figure 4-3 Summary information window 4 Click Next to select the default location, or click Change to modify the folder name. Figure 4-4 Destination Folder window 5 Review the selected settings. Click Back to change any selected settings. Click Install to begin the installation process with the selected settings. 43

44 Figure 4-5 Ready to Install the Program window 44

45 Chapter 4: Installing the Utility 6 The InstallShield Wizard Completed window appears (Figure 4-6). Click Finish to complete the installation. Figure 4-6 InstallShield Wizard Completed window 45

46 This page is intentionally blank. 46

47 5 Using the Utility Running the utility 1 Make sure the autosampler is connected to the host computer. 2 Click Start All Programs CETAC Technologies SpeedShift CETAC-SpeedShift, or navigate to the installation folder and double-click the utility. The utility loads and the main window appears. The buttons will be grayedout as shown until after the autosampler is queried. NOTE Querying the settings is performed after the host computer is connected to the autosampler, and the autosampler is powered on. This process reads the settings that are stored on the processor residing within autosampler (the default settings will be read the first time the query is performed), and displays them. When the query has been completed, the grayed-out fields will become active, allowing access to those fields and functions. 47

48 3 Select the serial port to which the autosampler is connected. 4 Click Initialize Communications. The utility will query the autosampler and display the current settings. If there is a communication error, exit the ASX-520 SpeedShift utility, cycle power on the autosampler, then restart the utility. Viewing the Current Settings The ASX-520 SpeedShift utility displays four user selectable settings. Once communications are established with the autosampler, the values displayed here will display the current settings stored on the internal processor of your autosampler. 48

49 Chapter 5: Using the Utility Changing a Setting The process for modifying any setting is as follows: 1 Select the appropriate COM port from the drop down menu. 2 Click Initialize Communications. 3 Change the chosen setting(s) to the desired values. 4 Click Set. You may change one or more setting at one time. Explanation of the Settings Pump Timeout Peristaltic pump timeout in seconds. The timeout controls how long the pump will run when the probe is in the rinse station and no other commands are sent to the autosampler. Setting the timeout to zero disables the timeout feature. Default=0. Pump Speed Level Peristaltic pump speed. The pump speed can be adjusted between 1 and 10, with 10 being the maximum speed. Default=4. X/Y Axis Travel Speed Speed of X- and Y-axis motion. The speed can be adjusted between 1 and 5. Default=2 for non-high speed units. High-speed units have three factory settings, corresponding with the DIP switch settings. ASX-520HS DIP Switch Setting Z Axis Travel Speed Corresponding Software Speed Setting The Z-Axis speed. The speed can be adjusted between 1 and 5. Default=2 for non-high speed units. As with X/Y Axis Travel Speed, high-speed units have three factory settings, corresponding with the DIP switch settings. 49

50 Explanation of the Controls Initialize Communications Sets up a communications channel between the utility and the autosampler. Before pressing this button, check that that the proper COM port has been selected. Set Sends the new settings to the autosampler. This process takes about 5-10 seconds. A small progress window will pop up to show the process. Factory Reset Configures the autosampler to use the original factory settings. Test XYZ Speed Exercises the autosampler in all three axes so you can see how speed changes affect the machine. Toggle Pump Turns the pump on and off. Use this to test the pump speed. The pump timeout does not apply when the pump is turned on using this button. Determining the Best Travel Speed for Your Application For ASX-260 and ASX-520 autosamplers, it may not be possible to use the highest speed setting. At higher speeds, the sudden acceleration and deceleration may cause droplet shedding from the probe tip, causing cross contamination. ASX-520HS autosamplers use an advanced acceleration algorithm which largely prevents these problems. NOTE Use caution when increasing the travel speed. Depending on the sample matrix, faster speeds have the potential for droplet shedding from the sample probe. Droplets could land in other samples or on nearby surfaces. 50

51 6 Operating a CETAC Autosampler Using a Terminal Program CETAC autosamplers can be controlled using a serial communications protocol. You can use any terminal emulation program, including: C-Term. This program is provided on the software CD, or it can be downloaded from the CETAC Web site. It runs on Windows 2000 and later. (recommended) HyperTerminal. This program was supplied with versions of the Windows operating system through Windows XP. This chapter explains how to operate a CETAC autosampler using either of the two programs. Using C-Term C-Term is a simple terminal program developed to validate the installation and functionality of various CETAC devices. C-Term communicates through a serial (RS-232) port on the host computer. If the device is connected to a USB port, the device driver will create a virtual serial port. C-Term is provided on the CETAC software CD. Starting C-Term 1 Check that the communication port connectors are properly attached between the host computer and the CETAC device. If the communications interface between the CETAC device and the host computer is not established correctly, the device will not function. 2 On the Start Menu, click All Programs, then CETAC, then Support Tools, then C- Term. 51

52 Figure 6-1 Starting C-Term Overview of the C-Term Window Once C-Term is loaded, the window shown in Figure 6-2 will open. The majority of C-Term s functions are available from this window. Figure 6-2 C-Term Window By default, typed commands are sent to the CETAC device connected to the opened port. The typed commands will appear in light green in the terminal buffer. Responses from the device will appear in red. Non-printing characters such as carriage returns will appear as ASCII hexadecimal numbers surrounded by square brackets, for example, [0D] is the carriage return character. 52

53 Chapter 6: Operating a CETAC Autosampler Using a Terminal Program Figure 6-3 Outgoing commands shown in green and incoming responses shown in red Configuring C-Term By default, C-Term attempts to open COM1 the first time it is executed. If the COM port that the CETAC device is connected to is not the default (COM1), then it will be necessary to configure C-Term to use the desired port. The default communications configuration is appropriate for use with the vast majority of CETAC devices. Exceptions are the ASX-8000 which requires a baud rate change and the AS300 emulator which uses non-printing characters are part of its command protocol. Modifying the default settings is described below. NOTE If COM1 (or the currently selected COM port) is in use by another program or is otherwise unavailable, a warning dialog box will pop up when C-Term starts stating that the COM port could not be opened. 1 On the Tools menu, click Setup Serial Port. Figure 6-4 Serial Port Setup Window 2 Select the desired COM port and, if necessary, the Baud rate used by the connected device then click OK. 53

54 The window will close and the settings will be saved. These new settings will be applied immediately and used thereafter unless changed again. NOTE All ASX-520 series autosamplers communicate at 9600 baud (which is the default.) NOTE Only installed COM ports, including USB virtual COM ports, will appear in the Comm Port menu. Setting Preferences If desired, the size of the scrollback buffer or the color of the outgoing and incoming texts can be changed (to work around color blindness, for example). 1 On the Tools menu, click Preferences. Figure 6-5 Preferences Window To change the Scrollback Buffer Length, either type the new value in the field or use the arrows adjust the value up or down. To change text color, click on the color bar and a color selection dialog box will appear. Select the new color and click OK. 2 Click Save to apply your settings and close the window. Using HyperTerminal 1 Using a serial cable, connect the CETAC autosampler with the computer. Plug each end of the serial cable into the COM 1 port of the autosampler and the computer, respectively. 2 Turn on the computer and select the Accessories folder. Select the HyperTerminal folder and then the HyperTerminal program. 54

55 Chapter 6: Operating a CETAC Autosampler Using a Terminal Program 3 A window will appear as in Figure 6-6. Enter COM 1 in the name box. Press the OK button. Figure 6-6 Connection Description Window 4 In the Connect To window, set Connect Using to COM 1, then click OK. Figure 6-7 Connect To Window 5 In the Properties window, set Bits per second to 9600 and Flow control to None. 55

56 Figure 6-8 COM1 Properties Window 6 Click OK. The HyperTerminal window will open. Figure 6-9 Com 1 Hyperterminal Window 7 On the File menu, click Properties. 56

57 Chapter 6: Operating a CETAC Autosampler Using a Terminal Program 8 On the Settings tab, click ASCII Setup Figure 6-10 Com 1 Properties Window 9 Click ASCII Setup. 10 Enable Echo typed characters locally and Append line feeds to incoming line ends, then click OK. 57

58 Figure 6-11 ASCII Setup Window 11 Turn on the autosampler. The HyperTerminal window should display an OK. Autosampler Commands The following commands will produce various responses of the autosampler. Command Ver Home Tray=n Tube=row-col-down Pmp on Pmp off Rinse Description Returns firmware version. Returns all axis to home position, same as power up. Defines tray size and n= #of positions. Legal values are 21, 24, 40, 60, and 90. Tube=row-column-down as defined by tray command. Example: Tube= Pump on if unit has a pump. Pump off if unit has a pump. Moves sipper to the rinse position, extends and retracts the sipper 3 times and starts rinse pump. Stays in down position with pump running. up,pmp off stops the pump. 58

59 Chapter 6: Operating a CETAC Autosampler Using a Terminal Program Down=n Up Settype=nnn Moves the z-axis down by the parameter(n) in mm. Do not run Down command if sipper is not all the way up on up position or damage may occur to sipper or z-axis. Moves z-axis to upper most postion. Sets the firmware personality. Table 6-1 Autosampler Commands You can use these commands to determine if the CETAC autosampler is communicating and functioning properly. If more assistance is needed, please contact CETAC customer service. 59

60 Manual Part Number Rev 3a Printed in USA

CETAC ASX-520 Family SpeedShift Utility

CETAC ASX-520 Family SpeedShift Utility CETAC ASX-520 Family SpeedShift Utility Software User's Guide Manual Part Number 480182 Rev 3a COPYRIGHT 2010-2011 CETAC Technologies 480182 Rev 3a, February, 2011 CETAC Technologies authorizes its customers

More information

CETAC ASXPRESS PLUS Rapid Sample Introduction System Upgrade for XLR-8 Autosamplers

CETAC ASXPRESS PLUS Rapid Sample Introduction System Upgrade for XLR-8 Autosamplers CETAC ASXPRESS PLUS Rapid Sample Introduction System Upgrade for XLR-8 Autosamplers Installation Guide Manual Part Number 480197 rev1 COPYRIGHT 2012 CETAC Technologies 480197 rev1, July, 2012 CETAC Technologies

More information

Upgrading Firmware for the CETAC ASXPRESS PLUS Rapid Sample Introduction System

Upgrading Firmware for the CETAC ASXPRESS PLUS Rapid Sample Introduction System Upgrading Firmware for the CETAC ASXPRESS PLUS Rapid Sample Introduction System Installation Guide 610094 Revision 3 1 COPYRIGHT 2010, 2011, 2015 Teledyne Technologies Inc. 610094 Revision 3, April, 2015

More information

Agilent ICP-OES SVS 2 Productivity Package Installation and Upgrade Instructions

Agilent ICP-OES SVS 2 Productivity Package Installation and Upgrade Instructions Agilent ICP-OES SVS 2 Productivity Package Installation and Upgrade Instructions NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies.

More information

ASXPRESS PLUS Rapid Sample Introduction System Quick Installation Guide

ASXPRESS PLUS Rapid Sample Introduction System Quick Installation Guide ASXPRESS PLUS Rapid Sample Introduction System Quick Installation Guide Manual Part Number 610092 Rev 8 ASXPRESS PLUS Quick Installation Guide You can and should arrange for expert installation of the

More information

ASX-260 RANDOM ACCESS AUTOSAMPLER ACCESSORIES AND SUPPLIES CATALOG

ASX-260 RANDOM ACCESS AUTOSAMPLER ACCESSORIES AND SUPPLIES CATALOG ASX-260 RANDOM ACCESS AUTOSAMPLER ACCESSORIES AND SUPPLIES CATALOG CETAC Technologies 14306 Industrial Road Omaha, Nebraska 68144, USA Phone: (402) 733-2829 Fax: (402) 733-5292 e-mail: custserv@cetac.com

More information

ASXPRESS Rapid Sample Introduction System ACCESSORIES AND SUPPLIES CATALOG

ASXPRESS Rapid Sample Introduction System ACCESSORIES AND SUPPLIES CATALOG ASXPRESS Rapid Sample Introduction System ACCESSORIES AND SUPPLIES CATALOG See the ASXPRESS PLUS Rapid Sample Introduction System Accessories and Supplies Catalog for additional parts. The ASXPRESS Rapid

More information

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual 621 Hunt Valley Circle New Kensington, PA 15068 3015-5547 Tel: 724-334-5000 Revision 4 Fax: 724-334-5001 May 17, 2013 Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Installation Note Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Part Number E4401-90498 Supersedes: E4401-90332 Printed in USA July 2005 Notice.

More information

Installation Guide. Wyse R Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

Installation Guide. Wyse R Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B Installation Guide Wyse R Class Conversion to WES7 Wyse USB Firmware Tool TM Release 1.10 Issue: 102910 PN: 883887-18L Rev. B Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual

More information

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2 SERVICE INSTRUCTION SI-09-04.1 Replaces (SI-09-04) March 2013 SERVICE INSTRUCTION Updating the firmware and software on the RCS-2 Important Note: It is highly recommended that all parameter data be backed

More information

Unpack the machine and its components. Cassette/Multi-purpose tray

Unpack the machine and its components. Cassette/Multi-purpose tray Set-Up Sheet Thank you for purchasing the Canon imageclass D320. To get your machine ready for use, please follow the instructions in this Set-Up Sheet before referring to any other documentation. Unpack

More information

ASX-560 / ASX-280 / XLR-860 Autosamplers

ASX-560 / ASX-280 / XLR-860 Autosamplers ASX-560 / ASX-280 / XLR-860 Autosamplers Service Manual Manual Part Number 480218 Rev1 COPYRIGHT 2015-2016 Teledyne Technologies Incorporated. All rights reserved. 480218 Rev1, September, 2016 Teledyne

More information

ED40. Development Kit. Quick Start Guide

ED40. Development Kit. Quick Start Guide ED40 Development Kit Quick Start Guide Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in this document without prior

More information

E2460GS Oscilloscope Upgrade Kit

E2460GS Oscilloscope Upgrade Kit Installation Instructions for E2460GS Oscilloscope Upgrade Kit Agilent 1670G-Series Logic Analyzers This kit upgrades either the Agilent Technologies 1670G, Agilent 1671G, Agilent 1672G, or the Agilent

More information

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers CRESCENDO /7200 G3 Processor Upgrade Card for Power Macintosh 7200/8200 Computers Quick Start Guide for Crescendo /7200 System Compatibility At this printing, processor upgrade cards are compatible with

More information

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE Introduction INSTALLATION INSTRUCTIONS: MCD USB MODULE 1. Introduction The USB Module can be used in conjunction with WinMaster to manage Danfoss soft starters. These instructions detail the installation,

More information

Dell Edge Gateway. Service Manual Series

Dell Edge Gateway. Service Manual Series Dell Edge Gateway 5000 Series Service Manual Computer Model: Dell Edge Gateway 5000/5100 Regulatory Model: N01G/N02G Regulatory Type: N01G001/N02G001 Notes, cautions, and warnings NOTE: A NOTE indicates

More information

*E * E E0606

*E * E E0606 75000 SERIES B Instrument BASIC Installation Note Copyright Agilent Technologies, Inc., 1990-2006 *E1300-90020* E1300-90020 E0606 Manual Part Number: E1300-90020 Printed: June 2006 Edition 1 Rev 2 Microfiche

More information

Series 3700 Screw Terminal Assemblies Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling

More information

G-MAX TM. ATX Series User s Manual

G-MAX TM. ATX Series User s Manual Copyright Notice Copyright 2001 Gigabyte Technology. All Rights Reserved. No part of this documentation, including but not limited to the products and software described in it, may be reproduced, transmitted,

More information

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Assembly Introduction The Replacement Kit provides a replacement backlight for the PanelMate Power Pro 1785 Series,

More information

FCC COMPLICANCE STATEMENT

FCC COMPLICANCE STATEMENT FCC COMPLICANCE STATEMENT For Users in the USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These rules are designed

More information

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips.

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips. TECHNICAL BULLETIN Upgrading Einstein Using the Einstein 1.5 Upgrade Kit This bulletin explains how to use the components of the CPC Upgrade Kit to upgrade a pre-1.5 version Einstein unit to the latest

More information

Intellex Digital Video Management System. Installing a CD-RW in Intellex

Intellex Digital Video Management System. Installing a CD-RW in Intellex Intellex Digital Video Management System Installing a CD-RW in Intellex 2 Intellex Digital Video Management System Notice Copyright The information in this manual was current when published. The manufacturer

More information

MISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00

MISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00 MISUMI SUPPORT SOFTWARE RS-Manager User s Manual C1 / C21 / C22 / P1 Ver. 2.00 EXWM14200 KE114 CONTENTS RS-Manager User s Manual Before getting started 1 1. About RS-Manager 2 2. Installing and uninstalling

More information

Cascade Configuration Tool

Cascade Configuration Tool Cascade Configuration Tool Version 1.0.10 Installation and Operations Manual 00-02-0724 01-25-11 Section 40 In order to consistently bring you the highest quality, full featured products, we reserve the

More information

Technical Information

Technical Information Technical Information DATE: January 16, 2014 MODEL: RSP 1570, RSX 1550, RSX 1560 Main Software Upgrade Instructions The RSP-1570, RSX-1550 and RSX-1560 have three separate software modules main software,

More information

In-Circuit Emulator. UNetICE for ARM

In-Circuit Emulator. UNetICE for ARM In-Circuit Emulator UNetICE for ARM User Manual Version 1.0 Rorixwell Inc. Authorized distributor by Embest Info&Tech Tel: +1 (416) 757 0764 Fax: +1 (416) 757 0764 10 Electro Road, Toronto, ON, M1R 2A7,

More information

Wireless Bore Gauge WBG. user and installation manual

Wireless Bore Gauge WBG. user and installation manual Wireless Bore Gauge WBG user and installation manual Contents Section Number & Title Page Number 1.0 Introduction 3 2.0 Installing a Gauge Head 4 3.0 Mechanical Adjustments 5 4.0 Set Up and Installation

More information

Set-Up Instructions. Set-Up Instructions. Unpack the machine and its components.

Set-Up Instructions. Set-Up Instructions. Unpack the machine and its components. Set-Up Instructions Thank you for purchasing the Canon FAXPHONE L80. To get your machine ready for use, please follow the instructions in this document before referring to any other documentation. Unpack

More information

User Manual. Thermo Scientific Orion

User Manual. Thermo Scientific Orion User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation

More information

EMC 10T "CE" Mechanical Upgrade Procedure

EMC 10T CE Mechanical Upgrade Procedure EMC 10T "CE" Mechanical Upgrade Procedure Kit Part Number: 009866-01 This procedure upgrades a non-ce compliant machine to the mechanical requirements of a CE compliant machine. Properly upgraded machines

More information

RC-SV Configuration Guide (Rev 4)

RC-SV Configuration Guide (Rev 4) Kramer Electronics, Ltd. RC-SV Configuration Guide (Rev 4) Software Version 2.1.2.69 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go

More information

Agilent Dissolution Tester Driver

Agilent Dissolution Tester Driver Agilent Dissolution Tester Driver Agilent Technologies Notices Agilent Technologies, Inc. 2011-2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,

More information

Dissolution System Drivers Operation Manual Rev. D

Dissolution System Drivers Operation Manual Rev. D Dissolution System Drivers Operation Manual 81-200-807 Rev. D Hanson Research Corporation 9810 Variel Avenue Chatsworth, CA 91311 USA (800) 821-8165 (818) 882-7266 FAX (818) 882-9470 www.hansonresearch.com

More information

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001 XPS 15 2-in-1 Service Manual Computer Model: XPS 15-9575 Regulatory Model: P73F Regulatory Type: P73F001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better

More information

5x86 Third Serial Port Installation

5x86 Third Serial Port Installation Introduction This document explains how to add a third serial port to P3, P4, P5, or P7 PowerStations that have a 5x86 CPU card. It includes instructions for opening the PowerStation, reconfiguring the

More information

* IMPORTANT * REGISTERING YOUR MACHINE

* IMPORTANT * REGISTERING YOUR MACHINE * IMPORTANT * REGISTERING YOUR MACHINE Thank you for your purchase of the Keyline 994 Laser. Before continuing with machine setup and use, please complete the following; COMPLETE PRODUCT REGISTRATION FORM

More information

ZCRMZNICE01ZEMG Crimzon In-Circuit Emulator

ZCRMZNICE01ZEMG Crimzon In-Circuit Emulator Quick Start Guide QS006602-0408 Introduction Zilog s ZCRMZNICE01ZEMG Crimzon (ICE), shown in Figure 1, provides Crimzon chip family emulation with a Trace and Event system for program debugging using Zilog

More information

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade HARMONi G3 imac Processor/FireWire Upgrade imac and Operating System Compatibility The HARMONi G3 imac processor/firewire upgrade is compatible only with imac 233, 266, and 333 MHz models (Revisions A-D);

More information

Start Here. Unpack. 1 Make sure you have these items: 2 Remove all the packing materials and tape.

Start Here. Unpack. 1 Make sure you have these items: 2 Remove all the packing materials and tape. Epson Stylus Pro 3880 Start Here Unpack 1 Make sure you have these items: Printer Power cord CD-ROM User's Guide Ink cartridges Rear sheet guide Limited Warranty Warning: The printer weighs about 43 pounds

More information

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

DP SATA 6Gb/s PCIe i/e Quick Installation Guide DP SATA 6Gb/s PCIe i/e Quick Installation Guide Introducing the SATA 6Gb/s PCIe i/e The DP SATA 6Gb/s PCIe i/e adds 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Dual

More information

GPIB-232CT-A IBCL EPROM Installation Guide

GPIB-232CT-A IBCL EPROM Installation Guide NATIONAL INSTRUMENTS The Software is the Instrument Installation Guide GPIB-232CT-A IBCL EPROM Installation Guide This guide describes how to replace the factory-installed EPROM that comes with your GPIB-232CT-A.

More information

FloBoss S600+ Field Upgrade Guide

FloBoss S600+ Field Upgrade Guide Form Number A6299 Part Number D301668X412 February 2011 FloBoss S600+ Field Upgrade Guide Remote Automation Solutions FloBoss S600+ Field Upgrade Guide Revision Tracking Sheet February 2011 This manual

More information

8380 RPC Return Path Combiner. User s Guide

8380 RPC Return Path Combiner. User s Guide 8380 RPC Return Path Combiner User s Guide Notice Every effort was made to ensure that the information in this manual was accurate at the time of printing. However, information is subject to change without

More information

TEL-218DRV TEL-X-Driver

TEL-218DRV TEL-X-Driver TEL-218DRV TEL-X-Driver TEL-Atomic, Incorporated P.O. Box 924 Jackson, MI 49204 1-800-622-2866 FAX 1-517-783-3213 email: telatomic@mindspring.com website: www.telatomic.com Features Angular Resolution:

More information

CncGcoder Models HD & HDx Manual

CncGcoder Models HD & HDx Manual CncGcoder Models HD & HDx Manual Table of Contents WELCOME... 3 IN THE BOX... 4 Optional Accessories...4 HANDHELD OVERVIEW... 5 Overview...5 Charging the Battery...6 Turning On and Off...6 Plugging in

More information

CETAC ADX-500 Online AutoDilution Accessory

CETAC ADX-500 Online AutoDilution Accessory CETAC ADX-500 Online AutoDilution Accessory Operator s Manual Manual Part Number 480065 Revision 2 COPYRIGHT 1999,2004,2011 CETAC Technologies 480065 Revision 2, August, 2011 CETAC Technologies authorizes

More information

USB-Link 2 Technical Guide

USB-Link 2 Technical Guide www.wattmaster.com USB-Link 2 USB-Link 2 Code: SS0073 Version 4.11 and up Table of Contents General Information... 3 USB-Link 2 Overview...3 System Requirements...3 Quick Guide... 4 USB-Link 2 Driver Installation

More information

USB-Link Technical Guide

USB-Link Technical Guide www.wattmaster.com USB-Link Technical Guide USB-Link Code: SS0070 Table of Contents General Information... 3 USB-Link Overview...3 System Requirements...3 Quick Guide... 4 Connection and Wiring... 5 USB-Link

More information

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A. Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter HP Part No. A4504-90601 Edition E1197 Printed in U.S.A. Hewlett-Packard Co. 1997 Printing History First Printing: November 1997 UNIX

More information

Dolphin ebase. Communication Cradle for the Dolphin 9700 Mobile Computer. User s Guide

Dolphin ebase. Communication Cradle for the Dolphin 9700 Mobile Computer. User s Guide Dolphin ebase Communication Cradle for the Dolphin 9700 Mobile Computer User s Guide Introduction The Ethernet Base (ebase) enables a single Dolphin 9700 computer to communicate with a host device over

More information

Redirector User Guide

Redirector User Guide Redirector User Guide Revision B November 04, 2005 Part Number GC-800-235 Copyright and Trademark Copyright 2004, Grid Connect, Inc. All rights reserved. No part of this manual may be reproduced or transmitted

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

SPEECH UPGRADE INSTALLATION GUIDE (MODEL 9100)

SPEECH UPGRADE INSTALLATION GUIDE (MODEL 9100) SPEECH UPGRADE INSTALLATION GUIDE (MODEL 900) TDN 0700-00062 07/2006 CORPORATE HEADQUARTERS: 522 E. RAILROAD STREET LONG BEACH, MS 39560 PHONE: (228) 868-37 FAX: (228) 868-0437 RMA (RETURN MATERIAL AUTHORIZATION)

More information

CyberPro PCI 4S Quick Installation Guide

CyberPro PCI 4S Quick Installation Guide CyberPro PCI 4S Quick Installation Guide Introducing the CyberPro PCI 4S The CyberPro PCI 4S high-speed serial I/O card provides four additional 9-pin serial ports. Features and Benefits Conforms to PCI

More information

ez80190 Development Kit Quick Start Guide

ez80190 Development Kit Quick Start Guide Introduction Follow this guide to install and begin using your new ez80190 Development Kit from ZiLOG. The setup procedure guides the user through: Software installation and online registration Hardware

More information

PCIe SATA 6G + PATA RAID Card

PCIe SATA 6G + PATA RAID Card PCIe SATA 6G + PATA RAID Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Features and Benefits Compliant with PCI-Experss Specification v2.0 and backward

More information

SATA 150 PCI Card 2-Channel

SATA 150 PCI Card 2-Channel SATA 150 PCI Card 2-Channel User Manual Ver. 3.00 All brand names and trademarks are properties of their Respective owners. Features Silicon Image SiI3512 SATA controller chip Compliant with PCI Specification,

More information

DBT-120 Bluetooth USB Adapter

DBT-120 Bluetooth USB Adapter DBT-120 Bluetooth USB Adapter Rev.2.1 (09/25/2002) 2 Contents Introduction... 5 Package Contents... 6 Installing Bluetooth Software... 6 Hardware Installation... 8 Introduction to Bluetooth Software...

More information

User s Guide TURBO Pinewood Derby Finish Line and Timer Release /31/2011 NewBold Products, Atlanta GA

User s Guide TURBO Pinewood Derby Finish Line and Timer Release /31/2011 NewBold Products, Atlanta GA User s Guide TURBO Pinewood Derby Finish Line and Timer Release 2.1 12/31/2011 NewBold Products, Atlanta GA www.newboldproducts.com 2 1. YOUR SHIPMENT Thank you for purchasing the TURBO, Pinewood Derby

More information

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM. 8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments

More information

ProSafe Plus Switch Utility

ProSafe Plus Switch Utility ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA May 2012 202-10524-04 2012 NETGEAR, Inc. All rights reserved No part of this publication maybe reproduced, transmitted,

More information

Part No. P May 4, Business Communications Manager. BCM Imaging Tool User Guide

Part No. P May 4, Business Communications Manager. BCM Imaging Tool User Guide Part No. P0609711 01.01 May 4, 2004 Business Communications Manager BCM Imaging Tool User Guide 2 Copyright 2004 Nortel Networks All rights reserved. May 4, 2004. The information in this document is subject

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....

More information

Using Hyperterminal with Vortex and Echofree Devices

Using Hyperterminal with Vortex and Echofree Devices Using Hyperterminal with Vortex and Echofree Devices Application Note Polycom Installed Voice Business Group September 2004 TABLE OF CONTENTS TABLE OF CONTENTS...1 TABLE OF CONTENTS...2 HYPERTERMINAL FOR

More information

UPort 2000 Series User s Manual

UPort 2000 Series User s Manual User s Manual Second Edition, December 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be

More information

How To Install: C4000 EMV Upgrade Kit

How To Install: C4000 EMV Upgrade Kit How To Install: C4000 EMV Upgrade Kit IMPORTANT: Before proceeding with installation please verify you have the current card reader bezel in the kit. Correct bezel will have a small eject pin hole below

More information

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual February 2006 Part Number: 140-10350 Copyright 2006 Magnetek Material Handling 2005 MAGNETEK MATERIAL HANDLING All rights reserved.

More information

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800 WTI Part No. 12348 Rev. B CPM Series Control Port Manager Models CPM-1600 and CPM-800 User's Guide 5 Sterling Irvine California 92618 (949) 586-9950 Toll Free: 1-800-854-7226 Fax: (949) 583-9514 http://www.wti.com

More information

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260 READ ME FIRST Windows NT *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 5260NT02A Version 1.2-A. Table of Contents Follow Steps 1 through 8 to complete

More information

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT INSTRUCTION MANUAL 1. DESCRIPTION KEPCO An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT BOP 1KW-MG RETROFIT KIT 219-0621 Kepco KIT 219-0621-(n) contains the parts used to upgrade the firmware for

More information

Wireless Modem Evaluation Board User s Guide

Wireless Modem Evaluation Board User s Guide Features Supports all CCI Modems and Radios Two independent transceivers and interfaces RS-232 Host Serial and USB Serial Communications RS-232,TTL Digital Serial and USB Host Interfaces Wireless modem

More information

Application Note Demonstrating the Serial Port Profile (SPP) Between BlueConnect and BTW 2002/5/29

Application Note Demonstrating the Serial Port Profile (SPP) Between BlueConnect and BTW 2002/5/29 Application Note Demonstrating the Serial Port Profile (SPP) Between BlueConnect and BTW 2002/5/29 1 Introduction As a technology leader in the wireless networking market, WIDCOMM s vision is to enable

More information

Installing Kurzweil K2661 ROM Options

Installing Kurzweil K2661 ROM Options Thank you for buying a ROM option for your K2661. This document shows you how to install either of the ROM options into your K2661. Option Kits and Part Numbers RMB3-26 Stereo Dynamic (SD) Piano ROM Option

More information

Remote Deposit Service

Remote Deposit Service Remote Deposit Service Start Up Guide *Screen shots are shown for illustrative purposes only and may vary based on the version of Windows you are currently using. Step 1: Confirm your PC meets system

More information

PF31XX FAMILY FIRMWARE UPDATE GUIDE. v1.2 Revised Nov 29, 2016

PF31XX FAMILY FIRMWARE UPDATE GUIDE. v1.2 Revised Nov 29, 2016 PF31XX FAMILY FIRMWARE UPDATE GUIDE Revised Table of Contents 1 Overview... 1 2 Firmware Update Process... 2 3 Document Revision History... 5 Page i 1 Overview This document will assist a user in completing

More information

Quick start guide for p5 520 ( )

Quick start guide for p5 520 ( ) Quick start guide for p5 520 (9111-520) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up a standard system. Users

More information

CyberSerial Dual PCIe Quick Installation Guide

CyberSerial Dual PCIe Quick Installation Guide CyberSerial Dual PCIe Quick Installation Guide Introducing the CyberSerial Dual PCIe The CyberSerial Dual PCIe high-speed serial I/O card provides two additional 9-pin serial ports. Features and Benefits

More information

Product Update. Overview. Table of Contents

Product Update. Overview. Table of Contents Product Update Overview This Product Update explains the changes to the products listed below. Microline 320/321 Turbo Microline 320/321 Turbo / n Microline 390/391 Turbo Microline 390/391 Turbo / n Microline

More information

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE C ONTENTS Choose an Installation Guide...... Before You Begin.............. 3 Disconnect the Light Cable........ 3 Cut the Light Cable............

More information

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions This STAR Comm Modem Kit was designed specifically for use with the Micro/PX-2000 micro. The STAR Comm Modem is an external modem that can

More information

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3 CRESCENDO /PB G3 Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers G3 Macintosh PowerBook and Operating System Compatibility The Crescendo/PB G3 processor upgrade card is compatible

More information

Sound Card Installation for Windows 95/98

Sound Card Installation for Windows 95/98 Sound Card Installation for Windows 95/98 Hardware Installation 1. Shut down Windows and power down system. Unplug power cable from the system. 2. Remove screws and open system enclosure. 3. Remove static

More information

Royal RVV-500 (B) Retrofit Kit

Royal RVV-500 (B) Retrofit Kit Optipay BV/RC/CC into a Non-Fascia Vending Machine This document contains information for installing and configuring the JCM Optipay DBV-01 Bill Validator, RC-10 Bill Recycler and A-66 Coin Changer into

More information

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0 Network USB over IP Server With 1-USB2.0 Port User Manual V1.0 1 2 TABLE OF CONTENTS COPYRIGHT...4 1. INTRODUCTION...5 PRODUCT OVERVIEW...5 COMPONENTS AND FEATURES...5 HARDWARE INSTALLATION...5 2. THE

More information

Cyber 2S1P 950 PCI Quick Installation Guide

Cyber 2S1P 950 PCI Quick Installation Guide Cyber 2S1P 950 PCI Quick Installation Guide Introducing the Cyber 2S1P 950 PCI The Cyber 2S1P 950 PCI high-speed serial I/O card provides two 9-pin serial ports and one parallel port. Key Features and

More information

UPDATING THE FIRMWARE IN FRAME BASED MODULES...

UPDATING THE FIRMWARE IN FRAME BASED MODULES... 7700/7800 MultiFrame Manual TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. REQUIREMENTS... 1 1.1.1. Requirements Serial Port Upgrade Method... 1 1.1.2. Requirements FTP Upgrade Method (For VistaLINK Capable Modules

More information

Intelligent Picomotor Control Modules Driver, Controller, and Joystick

Intelligent Picomotor Control Modules Driver, Controller, and Joystick USER S GUIDE Intelligent Picomotor Control Modules Driver, Controller, and Joystick U.S. Patents #5,140,470, #5,168,168, #5,303,035, #5,394,049, #5,410,206 Use of controls or adjustments, or performance

More information

BD Laser User Guide * IMPORTANT * PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AS IMPROPER USE MAY DAMAGE THE MACHINE AND VOID THE WARRANTY.

BD Laser User Guide * IMPORTANT * PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AS IMPROPER USE MAY DAMAGE THE MACHINE AND VOID THE WARRANTY. BD Laser User Guide * IMPORTANT * PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AS IMPROPER USE MAY DAMAGE THE MACHINE AND VOID THE WARRANTY. BD Laser arrives ready to use with jaws and cutters preinstalled.

More information

CommLink IV Technical Guide

CommLink IV Technical Guide www.wattmaster.com CommLink IV Technical Guide Table of Contents General Information... 3 CommLink IV Overview...3 Optional IP Module Kit...3 Optional Remote Link II...3 Installing CommLink IV ONLY...3

More information

Setting up an Intermec PM43 printer with InterDriver version M-0 or newer

Setting up an Intermec PM43 printer with InterDriver version M-0 or newer Setting up an Intermec PM43 printer with InterDriver version 7.3.5 M-0 or newer Setting up a bar code printer with 7.3.5 M-0 Intermec drivers or newer 1 INITIAL PRINTER CONFIGURATION When the printer is

More information

Replace the edrive TINI Module and Battery

Replace the edrive TINI Module and Battery Product All edrive Configurations Special Information INFORMATION: This service bulletin is for informational purposes only. It is intended for use by Northrop Grumman Cutting Edge Optronics (NG CEO) employees

More information

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015 EMC VNXe Adding input/output modules to a disk processor enclosure 302-000-206 REV 03 July, 2015 This document describes how to add input/output (I/O) modules to a DPE (disk processor enclosure). The printed

More information

Printhead alignment. 1. Turn the printer off. 2. Remove the top cover. See Additional information top cover removal on page 8.

Printhead alignment. 1. Turn the printer off. 2. Remove the top cover. See Additional information top cover removal on page 8. Printhead alignment Warnings: Whenever a printhead is replaced, it is necessary to perform the Mechanical alignment. Then, if a black printhead is replaced, perform the Black Printhead electronic alignment

More information

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories Contents Pages 3 & 4 The new tic counter system & home position sensor Page 5 Control Boxes Pages 6-8 Down

More information