1 HP Intelligent Modular Power Distribution Unit User Guide Part Number March 2010 (First Edition)

2 Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR and , Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor s standard commercial license. Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation. Intel, Pentium, and Itanium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Intended audience This document is for the person who installs and maintains power products. HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardous energy levels.

3 Contents Overview... 7 Important safety information... 7 Introduction... 8 Features... 8 Typical hardware configuration... 9 Web interface requirements Component identification and operation impdu components Control unit components Display unit components Viewing current on the display unit Intelligent extension bar components Resetting the intelligent extension bars Extension bar components Resetting the impdu Installing the HP Intelligent Modular Power Distribution Unit Installing the control unit Installing the control unit cord retention bracket Installing the 0U brackets Installing the 1U brackets Installing the control unit in the rack Installing the display unit Installing the intelligent extension bars Installing the extension bars using a single configuration Installing the extension bars using a double configuration Connecting the ground bonding cable Connecting the impdu to the power source Connecting devices Checking the display unit LED indicator Connecting the network cable Connecting a host computer Checking the circuit breakers Launching a terminal emulation program Configuring the impdu for remote access HP Intelligent PDU web interface HP Intelligent PDU web interface overview Accessing the web interface Signing in to the web interface Browser security alert Establishing a secure session for Internet Explorer Establishing a secure session for Mozilla Establishing a secure session for Firefox Navigating the web interface Home tab... 36

4 Overview menu Alarms menu Identification menu Status menu Control menu Device Registration menu Logs tab Event Log menu Application Log menu Setup tab My Account menu User Accounts menu Network menu Network Management menu PDU Thresholds menu Help tab About menu Contents menu Info & Updates menu HP Intelligent PDU Service Menu HP Intelligent PDU Service Menu overview Accessing the Service Menu Telnet session Terminal emulation session POST Navigating the menus Service Menu Main menu Network Configuration submenu System Configuration submenu User Accounts submenu My Account submenu Troubleshooting Admin IP address displays incorrectly on the Application Log Browser does not display the web interface Browser incorrectly displays English or Japanese characters Browsing becomes very slow after an alarm is triggered Browsing becomes very slow or stops responding when accessed by multiple Firefox sessions Certificate error Connection closed by remote host error message displays Control unit LED indicator illuminates or flashes Device names display incorrectly Display unit LED indicator illuminates or flashes Event notification messages do not appear on console screen Event notifications are not being sent Flash update fails over a serial connection Help files do not appear HP SIM lists a discovered impdu as Unmanaged in the System Type column HPFlash does not install image.bin on a Pentium III Invalid IP address IPv4 DHCP assigned address is not listed with other network interface parameters Links in traps and s do not work correctly for Linux... 71

5 No power Non-admin users cannot log in through telnet Operating system firewall prevents impdu functionality Receiving a security error Service Menu does not appear on a serially-connected host computer Unable to obtain a valid network address error message displays Unable to send a test Unable to set event delays using telnet User account locked after entering incorrect password When resetting or powering on the impdu, the browser does not display the web interface Spares Ordering spares Spare parts list Hardware options Technical support Before you contact HP HP contact information Regulatory compliance notices Regulatory compliance identification numbers Federal Communications Commission notice FCC rating label Class A equipment Class B equipment Declaration of conformity for products marked with the FCC logo, United States only Modifications Cables Canadian notice (Avis Canadien) European Union regulatory notice Disposal of waste equipment by users in private households in the European Union Chinese notice Japanese notice Korean notice BSMI notice Alert messages impdu alarms Systems Insight Manager integration Systems Insight Manager overview Discovering the impdu Configuring HP SIM to receive traps Configuring the impdu to send traps to HP SIM Security considerations Security considerations overview Installing a digital certificate and encryption key for SSL Optional power monitoring using SNMP SNMP monitoring Updating the firmware Updating the firmware overview Serial Flash Mode... 88

6 FTP Flash Mode SNMP trap codes SNMP trap codes Application recovery Recovering a corrupted application Acronyms and abbreviations Index... 96

7 Overview Important safety information NOTE: The HP Intelligent Modular Power Distribution Unit (impdu) is intended for use only with information technology equipment (ITE) loads in racks or similar computer room applications. Extension bars ship with some kits. These extension bars are designed for use with Compaq/HP Modular Power Distribution Control Units and HP Uninterruptible Power Systems (UPSs). The extension bars can be used with other power sources, provided that the source includes branch circuit overcurrent protection not exceeding 20 A. WARNING: To reduce the risk of personal injury from electric shock, do not remove the cover. There are no field-serviceable or user-serviceable components inside. WARNING: A risk of personal injury from electric shock and hazardous energy levels exists. The installation of options and routine maintenance and service of this product must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with AC power products. Follow these safety precautions when connecting multiple hardware components to power sources. WARNING: To reduce the risk of personal injury or damage to the equipment: Plug the input power cord into a grounded (earthed) electrical outlet that is located near the equipment and is easily accessible. Be sure that the load products connected to the HP Intelligent Modular Power Distribution Unit (impdu) are adjusted for, or otherwise capable of operation from the same line voltage supplying the impdu. Failure to verify the voltage can lead to severe equipment damage. Do not overload the impdu. The total input current rating of all equipment connected to each output cannot exceed the total output rating marked on the impdu. WARNING: To reduce the risk of personal injury from high-leakage current, verify earth connection before connecting the power supply. The summation of input power for multiple pieces of information technology equipment through the use of power products can result in high-leakage currents. If the total system leakage current for a system of components exceeds 3.5 ma: The use of a detachable input power cord is prohibited. The input power cord must be securely attached, and it should be connected to the AC mains by hardwiring or through the use of a non-residential, industrial-style plug that maintains positive earth connection. If the total system leakage current through the ground conductor exceeds 5% of the input current per line under normal operating conditions, the system loads should be divided among multiple power connections. Overview 7

8 Introduction Features The HP Intelligent Modular Power Distribution Unit (impdu) has an industry first feature of power topology automatic discovery. The impdu automatically discovers HP ProLiant servers* powered by the impdu, enabling data center managers to know with certainty that installed equipment is powered as designed. Unexpected server shutdowns can occur due to human error as routine maintenance tasks are performed, and are often the first indication that a server is not powered as documented. The ability to automatically determine the power topology increases reliability and allows data center managers to maximize the rack, power, and thermal resources in the data center. The impdu power topology discovery also enables HP Thermal Logic solutions, such as Insight Control Power Manager advanced group power capping for ProLiant DL/ML and Integrity servers with ilo 2 management processors and optional upgrade licenses, to reach their full potential by reducing human error when assigning servers to a power capping group. The impdu enables you to monitor, manage, and control power environments. Multiple devices can monitor the impdu over the network connection. The input voltage of a single phase impdu is 200 to 240 VAC. The input voltage of a three phase impdu is 200 to 240 VAC or 380 to 415 VAC, depending on the model. For configuration and status monitoring, the impdu includes: HP Intelligent PDU web interface (on page 32) A graphical interface that is accessed with a web browser HP Intelligent PDU Service Menu (on page 59) A text-based menu that is accessed through telnet or a terminal emulation session To benefit from the latest product enhancements, update to the latest versions of firmware and software. NOTE: To download the latest versions of firmware and software, see the HP website ( * Power topology automatic discovery requires HP ProLiant servers with ilo 2 v2.0 or newer firmware, combined with the intelligent extension bar, discovery data power cords, and HP ProLiant 94% efficiency common slot power supplies. impdu features include: Power topology automatic discovery for HP ProLiant servers with ilo 2 v2.0 or newer firmware when combined with the intelligent extension bar, discovery data power cords, and HP ProLiant 94% efficiency common slot power supplies. Sends customized notification messages. Can be configured to send alert traps to HP Systems Insight Manager and other SNMP management programs. Displays logs for analysis Control unit features include: Overview 8

9 Flexible mounting in 0U or 1U configurations, maximizing rack space (no additional parts are required for mounting) Overcurrent and short-circuit protection for each output (UL-489-listed circuit breakers) IEC-320 C19 outlets to power extension bars, intelligent extension bars, or other IEC-320 C20 plugcompatible equipment Easy identification and reset of overload circuits (circuit breakers move to Off position), minimizing downtime Power cord retention Recessed handles to prevent inadvertent power-off Display unit features include: Two-digit LED display that shows the current in each impdu, load segment/extension bar, or intelligent extension bar outlet in tenths Three scroll buttons to scroll through values Two interior LEDs, which indicate power and alarms One exterior LED, which indicates normal operation During normal conditions, all impdu component LEDs illuminate green. The blue UID illuminates on the extension bars to indicate which component corresponds to the current that appears on the display unit. Intelligent extension bar features include: Multiple power outlets, conveniently located for quick and easy equipment power connections Green power indicator for the intelligent extension bar and each individual outlet Blue UID indicator for the component that corresponds to the current that appears on the impdu display unit Manual on/off control for each intelligent extension bar, outlet, and outlet UID using the impdu web interface Attached 2.4-m (8-ft) input power cords Power cord retention Extension bar features include: Multiple power outlets, conveniently located for quick and easy equipment power connections Green power indicator Blue UID indicator that illuminates when the extension bar current appears on the impdu display unit Manual on/off control for each extension bar UID using the impdu web interface Attached 2.4-m (8-ft) input power cords Power cord retention Typical hardware configuration The total number of load segments is six. Load segment 1 always corresponds to the outlet closest to the control unit power cord. Overview 9

10 Up to six extension bars and intelligent extension bars can be connected to provide 30 IEC-320 C13 outlets. Web interface requirements The following table lists the minimum requirements necessary to operate the web interface. CAUTION: It is highly recommended that browser access to the impdu is isolated from outside access using a firewall or isolated network. Software Web browser on a client Monitor resolution Browser Microsoft operating systems Microsoft Internet Explorer 6.0 with Service Pack 1 (32-bit only) Microsoft Internet Explorer 7.0 (32-bit only) Mozilla Firefox 3.0.x Red Hat Linux 4 operating system Firefox 2.0.x (included in the bundle) Red Hat Linux 5 operating system Firefox (included in the bundle) SUSE Linux 10 operating systems Firefox 2.0.x Mozilla 1.7.x Minimum supported resolution of 1024 x 768, 16-bit high color (maximize browser window for optimal display) Overview 10

11 Component identification and operation impdu components Callout Description 1 Display unit 2 Control unit 3 Extension bar 4 Intelligent extension bar Component identification and operation 11

12 Control unit components Callout Description 1 Circuit breaker for load segment 1 2 Circuit breaker for load segment 2 3 Circuit breaker for load segment 3 4 Circuit breaker for load segment 4 5 Circuit breaker for load segment 5 6 Circuit breaker for load segment 6 7 Serial connector for additional impdu connection 8 Serial connector for display unit connection 9 Network connector 10 Reset button* 11 IEC-320 C19 outlet for load equipment power or extension bar attachment (load segment 6) 12 IEC-320 C19 outlet for load equipment power or extension bar attachment (load segment 5) 13 IEC-320 C19 outlet for load equipment power or extension bar attachment (load segment 4) 14 IEC-320 C19 outlet for load equipment power or extension bar attachment (load segment 3) 15 IEC-320 C19 outlet for load equipment power or extension bar attachment (load segment 2) 16 IEC-320 C19 outlet for load equipment power or extension bar attachment (load segment 1) *When you press the Reset button, power to the outlets is maintained. Management functionality is momentarily lost while the components reset. Component identification and operation 12

13 Display unit components Callout Description 1 LED numeric display for amperage of load segments/extension bars and intelligent extension bar outlets 2 LED numeric display for PDU current selection (display corresponds to PDU current) 3 LED numeric display for load segment/extension bar current selection (display corresponds to load segment/extension bar current) 4 LED numeric display for intelligent extension bar outlet current selection (display corresponds to intelligent extension bar outlet current) 5 Scroll button for intelligent extension bar outlet current selection display (Outlet) 6 Scroll button for load segment/extension bar current selection display (Ext Bar) 7 Scroll button for PDU current selection display (PDU) 8 Serial port for host computer connection 9 Serial port for control unit connection 10 Reset button* 11 Alarm LED 12 Power LED *When you press the Reset button, power to the outlets is maintained. Management functionality is momentarily lost while the components reset. Viewing current on the display unit To view the current of impdu components: Component identification and operation 13

14 1. Press the display unit button that corresponds to the component. o o o PDU Scrolls through the PDUs in the impdu installation LS Scrolls through the impdu load segments/extension bars in the impdu installation Outlet Scrolls through the intelligent extension bar outlets in the impdu installation The current selection displays in the LED numeric display above the corresponding button. NOTE: When a load segment has an intelligent extension bar attached, the Amps numeric LED display alternates between the load segment value and the outlet value. The Outlet numeric LED display simultaneously alternates between the outlet number and "-" to indicate the load segment total current. 2. Continue to press the button to scroll through the components until the display shows the desired current selection. The Blue UID indicator illuminates on the extension bar or intelligent extension bar outlet to indicate which current is displayed. Intelligent extension bar components The total rating of the intelligent extension bar is 16 A. Callout Description 1 Row of green power indicators (one for each outlet) 2 Row of blue UID indicators (one for each outlet) m (8-ft) input power cord 4 Five intelligent 10 A, IEC-320 C13 outlets 5 Blue UID indicator for the intelligent extension bar 6 Green power indicator for the intelligent extension bar 7 Reset button* *When you press the Reset button, power to the intelligent outlets is maintained. Management functionality is momentarily lost while the intelligent extension bar resets. Component identification and operation 14

15 Resetting the intelligent extension bars To reset the intelligent extension bars: 1. Press the Reset button on intelligent extension bar you want to reset. The Reset button is located next to the input power cord. 2. Wait for the intelligent extension bar to reboot. When you press the Reset button, power to the intelligent outlets is maintained. Management functionality is momentarily lost while the intelligent extension bar resets. Extension bar components The total rating of the extension bar is 16 A. Callout Description 1 Five 10 A, IEC-320 C13 outlets 2 Green power indicator 3 Blue UID indicator m (8-ft) input power cord Resetting the impdu To reset the display unit, control unit, and all connected intelligent extension bars: 1. Press the Reset button on either the display unit or the control unit. 2. Wait for the impdu to reboot. When you press the Reset button, power to the outlets is maintained. Management functionality is momentarily lost while the components reset. Component identification and operation 15

16 Installing the HP Intelligent Modular Power Distribution Unit Installing the control unit Installing the control unit cord retention bracket The control unit cord retention bracket is shown for clarification in the following diagram, though installation of the control unit cord retention bracket is optional. Installing the 0U brackets Installing the HP Intelligent Modular Power Distribution Unit 16

17 Installing the 1U brackets The rack ears are reversible, so the impdu can be installed with either the circuit breakers or the power cords facing forward. Two impdus can be mounted in a 1U configuration by mounting one impdu in the front of the rack and the other impdu in the rear of the rack. Installing the control unit in the rack The control unit can be mounted in the rack two different ways, depending on whether you install the 0U brackets (A) or the 1U brackets (B) to the control unit. Installing the 1U control unit in a square-holed rail NOTE: Use the M6 screws and cage nuts that shipped with the rack when installing in a square-holed rail. Installing the HP Intelligent Modular Power Distribution Unit 17

18 Installing the 0U control unit in a square-holed rail NOTE: Use the M6 screws and cage nuts that shipped with the rack when installing in a square-holed rail. Installing the HP Intelligent Modular Power Distribution Unit 18

19 Installing the 0U control unit in a square- and round-holed rail NOTE: Use the sheet metal mounting screws that are included with this kit when installing in a square- and round-holed rail. Installing the HP Intelligent Modular Power Distribution Unit 19

20 Installing the display unit 1. Connect the serial cable to the PDU serial connector on the display unit. 2. Install the display unit on the inside of the rack door. Attach the provided screws through the holes on the perforated door. Installing the HP Intelligent Modular Power Distribution Unit 20

21 3. Connect the serial cable to the serial connector on the control unit. Installing the HP Intelligent Modular Power Distribution Unit 21

22 Installing the intelligent extension bars Installing the HP Intelligent Modular Power Distribution Unit 22

23 Installation of the cord retention bracket is optional. Installing the HP Intelligent Modular Power Distribution Unit 23

24 Installing the extension bars using a single configuration The cord retention bracket (1) is shown for clarification in the following diagram, though installation of the cord retention bracket is optional. Installing the HP Intelligent Modular Power Distribution Unit 24

25 Installing the HP Intelligent Modular Power Distribution Unit 25

26 Installing the extension bars using a double configuration The cord retention brackets (1) are shown for clarification in the following diagram, though installation of the cord retention brackets is optional. Installing the HP Intelligent Modular Power Distribution Unit 26

27 Connecting the ground bonding cable The ground bonding screw is provided as an attachment point for conductors. Use a ground bonding cable if the rack contains any conductors for the purpose of functional grounding or bonding of ungrounded metal parts. Installing the HP Intelligent Modular Power Distribution Unit 27

28 The ground bonding cable is not included in this kit. Connecting the impdu to the power source WARNING: To prevent injury from electric shock or damage to the equipment: Plug the input line cord into a grounded (earthed) electrical outlet that is installed near the equipment and is easily accessible. Do not disable the grounding plug on the input line cord. The grounding plug is an important safety feature. Do not use extension cords. Connect the impdu to a grounded utility power outlet. The AC branch circuit overcurrent protection should be sized according to the standard of the plug configuration on each model. The maximum overcurrent rating for each model is listed in "Connecting devices (on page 28)." Connecting devices When connecting devices, distribute the loads evenly across the phase to remain within the capability of the extension bars and control unit. Do not overload the impdu. The total current rating of all equipment connected to each output cannot exceed the total output rating marked on the impdu. Control unit Input rating of control unit Max branch circuit rating Individual outlet rating and style Load circuit breaker rating Individual phase rating* AF520A NA/JPN 24 A Single phase 30 A 16 A IEC-320 C19 20 A 24 A AF521A NA/JPN 40 A Single phase 50 A 16 A IEC-320 C19 20 A 40 A AF522A NA/JPN 24 A 3 phase 30 A per phase 16 A IEC-320 C19 20 A A per phase Installing the HP Intelligent Modular Power Distribution Unit 28

29 Control unit AF533A NA/JPN AF523A NA/JPN AF525A INTL AF526A INTL AF527A INTL Input rating of control unit 40 A 3 phase 48 A 3 phase 32 A Single phase 16 A 3 phase 32 A 3 phase Max branch circuit rating 50 A per phase 60 A per phase Individual outlet rating and style 16 A IEC-320 C19 16 A IEC-320 C19 32 A 16 A IEC-320 C19 16 A per phase 32 A per phase * For 3 phase impdus, each phase is defined as follows: Phase A Outlet 3 and outlet 6 Phase B Outlet 2 and outlet 5 Phase C Outlet 1 and outlet 4 16 A IEC-320 C19 16 A IEC-320 C19 Load circuit breaker rating Individual phase rating* 20 A 23.1 A per phase 20 A A per phase 16 A 32 A 16 A 16 A per phase 16 A 32 A per phase Extension bar Total rating of extension bar Outlet style Individual outlet rating AF528A 16 A IEC-320 C13 10 A No AF529A Intelligent 16 A IEC-320 C13 10 A Yes Outlet monitor and control Checking the display unit LED indicator If the LED indicator that is visible when the rack door is closed (1) illuminates or flashes, see the "Troubleshooting (on page 67)" section for more information. Connecting the network cable Connect a standard Ethernet cable between the network connector on the control unit and a network jack. This connection is used to access the impdu through telnet or the web interface. Installing the HP Intelligent Modular Power Distribution Unit 29

30 Connecting a host computer Connect a serial cable between the PC serial connector on the display unit and the serial connector on a host computer. This connection is used to configure and access the impdu through a terminal emulation program, as well as to upgrade the impdu. CAUTION: You cannot bypass the display unit and connect a host computer directly to the impdu. The host computer must be connected to the display unit to ensure proper communication with the impdu. Checking the circuit breakers If power to a device is interrupted, check the circuit breakers and reset if necessary. If power is still not restored, contact your HP authorized service representative. Launching a terminal emulation program NOTE: HyperTerminal is the serial communication program provided with Microsoft Windows and is used in this section as an example for setting up a terminal emulation session. If you are using another utility, the steps might be different. 1. Be sure that you have connected a host computer. 2. On the host computer, click Start, and select Programs>Accessories>Communications>HyperTerminal. The Connection Description window appears. 3. Enter a description, select an icon for the connection, and then click OK. The Connect To window appears. 4. Select the serial connector on the host computer to which the serial cable is attached, and then click OK. The COM Properties window appears. 5. Select the following parameter values, and then click OK. o o o o o Bits per second Data bits 8 Parity None Stop bits 1 Flow control None Configuring the impdu for remote access 1. Be sure that you have connected a network cable to the control unit. 2. Be sure that you have connected a serial cable to the display unit and the host computer with an open terminal emulation session. 3. Press the Reset button on either the display unit or the control unit. Installing the HP Intelligent Modular Power Distribution Unit 30

31 On the terminal emulation session screen running on the host computer, the POST executes, and the following prompt appears: Press any key in 5 seconds to enter the Service menu. 4. Press a key to enter the HP Intelligent PDU Service Menu (on page 61). 5. On the Service Menu, enter 1 at the prompt to select Module Configuration. The HP Intelligent PDU Main menu (on page 61) appears. Use the Main menu to configure the minimum settings required to access the impdu remotely using telnet or the web interface. You can configure other settings using this menu in conjunction with a terminal emulation program or a telnet connection. NOTE: If your network is configured with a DHCP server, the network settings are automatically assigned. Verify and note the assigned values. 6. If your network is not configured with a DHCP server: a. On the Main menu, enter 1 at the prompt to open the Network Configuration submenu (on page 61). b. Enter 1 at the prompt to open the IPv4 Network Configuration submenu. c. Enter 4 at the prompt, and then change the boot mode to static IP. d. Enter 1 at the prompt, and then enter the IP address of the impdu. e. Enter 2 at the prompt, and then enter the subnet mask of the impdu. f. Enter 3 at the prompt, and then enter the default gateway of impdu. g. Enter 0 at the prompt to return to the Main menu. 7. Configure web access: a. On the Main menu, enter 1 at the prompt to open the Network Configuration submenu (on page 61). b. Enter 4 at the prompt to open the Web Access Configuration submenu (on page 62). c. Use the submenu options to enable or disable web access, and then configure the associated port, if necessary. 8. Configure telnet access: a. On the Main menu, enter 1 at the prompt to open the Network Configuration submenu (on page 61). b. Enter 3 at the prompt to open the Remote Console Configuration submenu. c. Use the submenu options to enable or disable telnet access, and then configure the associated port, if necessary. 9. Enter 0 at the prompt to return to the Main menu. 10. Enter 0 at the prompt to exit the configuration utility. 11. Enter s at the prompt to save the settings and close the configuration utility. Installing the HP Intelligent Modular Power Distribution Unit 31

32 HP Intelligent PDU web interface HP Intelligent PDU web interface overview The web interface graphically displays various measurements and warning and alarm messages from the impdu. Also, system values can be configured through the web interface and sent to the impdu. NOTE: All status information and configuration parameters included on the HP Intelligent PDU web interface are available using the HP Intelligent PDU Service Menu (on page 59). Accessing the web interface CAUTION: It is highly recommended that browser access to the impdu is isolated from outside access using a firewall or isolated network. Use a web browser to access the HP Intelligent PDU web interface: 1. If necessary, configure the impdu by: a. Launching a terminal emulation program (on page 30). b. Configuring the impdu for remote access. 2. Be sure that you have connected the network cable ("Connecting the network cable" on page 29) to the impdu. 3. Launch a supported browser. The browser window appears. 4. In the Address field (Microsoft Internet Explorer) or the Location field (Mozilla and Firefox), enter: where xxx.xxx.xxx.xxx is the IPv4 or IPv6 address, and port is the HTTPS port. The default port is 443. The log in screen appears. 5. Sign in through the web browser ("Signing in to the web interface" on page 32). NOTE: For a complete list of the browser requirements, see "Web interface requirements (on page 10)." Signing in to the web interface 1. Enter the user name in the User Name field. The default user name is admin. 2. Enter the password in the Password field. The default password is admin. NOTE: Passwords are case-sensitive. 3. Select the appropriate language in the Language dropdown box. HP Intelligent PDU web interface 32

33 4. Click Sign In. The HP Intelligent PDU web interface appears. -or- Click Clear to clear the credentials. For information regarding the interface, see "Navigating the web interface (on page 35)." For instructions on changing the password, see "My Account menu (on page 46)." Admin session logins, logouts, and terminations are recorded in the Application Log menu (on page 45). The console session timeout length can be modified using the Remote Access tab (on page 55). The following is a list of recommended password guidelines. Passwords should not be shared with others. Passwords should be limited to one or two people, if shared with others. Passwords should be coordinated to prevent inadvertent logouts, should more than one person know them. Passwords are case-sensitive. Passwords can be between 1 and 15 alphanumeric characters in length. HP Intelligent PDU web interface 33

34 Browser security alert Secure browsing requires the use of SSL. SSL is a protocol layer that lies between HTTP and TCP that provides secure communication between a server and a client and is designed to provide privacy and message integrity. SSL is commonly used in web-based transactions to authenticate the web server, which indisputably identifies the server to the browser. SSL also provides an encrypted channel of communication between the server and the browser. The encrypted channel ensures integrity of the data between the web server and the browser, so that data can neither be viewed nor modified while in transit. The impdu uses a system generated certificate and unique key. An integral part of SSL is a security certificate, which identifies the impdu. If your browser displays a security alert when browsing to the impdu, it can be for one of several reasons: The certificate is untrusted, meaning it was signed by a certifying authority that is unknown to your browser. The certificate has expired or is not yet valid. This condition can occur if you issue your own certificate and it has expired. The Common Name (name or IP address) on the certificate does not match the name or IP address of the site in the browser address field. For more information about security considerations, see "Security considerations overview (on page 85)." For more information about certificates and keys, see "Installing a digital certificate and encryption key for SSL (on page 85)." Establishing a secure session for Internet Explorer The first time you browse to the impdu, the Secure Session screen appears. To ensure a secure connection, verify that you are browsing to the desired impdu: 1. Click View Certificate. 2. Verify that the name in the Issued To field is the name of your impdu. 3. Perform any other steps necessary to verify the identity of the impdu. CAUTION: If you are not sure this is the desired impdu, do not proceed. Importing a certificate from an unauthorized source relays your login credentials to that unauthorized source. Exit the certificate window and contact the system administrator. After verifying the impdu, do one of the following: Import the certificate and proceed. a. Click View Certificate. The certificate appears. b. Click Install Certificate. The Certificate Import wizard runs. c. Click Next. The Certificate Store screen appears. d. Select Automatically select the certificate store based on the type of certificate, and then click Next. e. Click Finish. A message appears, asking for verification of the root store. f. Click Yes. HP Intelligent PDU web interface 34

35 Proceed without importing the certificate by clicking Yes at the Security Alert window. You continue to receive the Security Alert each time you log in until you import the certificate. Your data is still encrypted. Exit and import the certificate into your browser from a file provided by the administrator. a. Click No at the Security Alert window. b. Obtain an exported certificate file from the administrator. NOTE: If using Internet Explorer, you can manually import the file into the browser by clicking Tools>Internet Options>Content>Certificates>Import. Establishing a secure session for Mozilla The first time you browse to the impdu, the Secure Session screen appears. To ensure a secure connection, verify that you are browsing to the desired impdu: 1. Click Examine Certificate. 2. Verify that the name in the Issued To field is the name or IP address of your impdu. 3. Perform any other steps necessary to verify the identity of the impdu. 4. After verifying the impdu, do one of the following: a. Click either Accept this certificate permanently or Accept this certificate temporarily for this session. b. Click OK. NOTE: If using Mozilla, you can manually import the file into the browser by clicking Edit>Preferences>Privacy & Security>Certificates>Manage Certificates>Authorities>Import. Establishing a secure session for Firefox The first time you browse to the impdu, the Secure Session screen appears. To ensure a secure connection, verify that you are browsing to the desired impdu: 1. Click Examine Certificate. 2. Verify that the name in the Issued To field is the name or IP address of your impdu. 3. Perform any other steps necessary to verify the identity of the impdu. 4. After verifying the impdu, do one of the following: a. Click either Accept this certificate permanently or Accept this certificate temporarily for this session. b. Click OK. NOTE: If using Firefox, you can manually import the file into the browser by clicking Edit>Preferences>Advanced>Security>View Certificates>Authorities>Import. Navigating the web interface The web interface is divided into three frames: HP Intelligent PDU web interface 35

36 Top frame Contains a Sign Out hyperlink, Home tab, Logs tab, Setup tab, and Help tab. o o o o o Click the Sign Out hyperlink to log out of the interface. Click the Home tab to see the menu options for viewing general status information. For more information, see "Home tab (on page 36)." Click the Logs tab to see the menu options for displaying data logs. For more information, see "Logs tab (on page 43)." Click the Setup tab to see the menu options for configuring the impdu and setting up and modifying user accounts. For more information, see "Setup tab (on page 45)." Click the Help tab to access the interface information and help section. For more information, see "Help tab (on page 56)." Left navigation frame Contains a list of menu options, a list of alarms and warnings, and a legend. o The options menu is dynamic, and the options listed change depending on the tab selected and your access rights. o The list of alarms and warnings displays the individual alarm status for the impdu. The graphical indicator displays the number of active alarms and displays the icon for the most severe alarm. The date and time of the last update is also indicated. o The legend displays the meaning of symbols used in the interface. Expand and collapse the legend by clicking the arrow in the upper right corner. Main frame Contains the various interface screens based on the menu option selected in the left navigation frame. Home tab Menu options listed under the Home tab include: Overview menu (on page 37) Alarms menu (on page 38) HP Intelligent PDU web interface 36

37 Identification menu (on page 38) Status menu (on page 39) Control menu (on page 40) Device Registration menu (on page 42) Overview menu Click Overview in the left navigation frame to display the Overview screen. This screen displays overall views of the impdu status. NOTE: Load segment 1 always corresponds to the outlet closest to the control unit power cord. Current, voltage, and load information are displayed on the right side of the screen for each load segment. A status icon indicates the current status of each load segment ( Normal, Warning, or Critical). The load percent for the impdu is displayed graphically on the left side of the screen. The color on the meter represents the total load of the impdu. Color Green Yellow Red Status Normal Warning Critical Click Refresh to refresh the screen. Click Help to view online help. HP Intelligent PDU web interface 37

38 Alarms menu Click Alarms in the left navigation frame to display the Alarms screen. This screen displays the alarms for the impdu. The alarms are listed in alphabetical order. Each entry includes a severity icon ( Informational, Normal, Warning, or Critical), a description, and the date and time at which the alarm most recently occurred. Click Refresh to refresh the screen. Click Help to view online help. Identification menu Click Identification in the left navigation frame to display the Identification screen. This screen contains contact information and device information for the impdu and device information for each load segment. NOTE: Load segment 1 always corresponds to the outlet closest to the control unit power cord. HP Intelligent PDU web interface 38

39 Enter the system name and contact information using the System Information tab (on page 50) on the Network Management screen. Click Refresh to refresh the screen. Click Help to view online help. Status menu Click Status in the left navigation frame to display the Status screen. This screen displays the status for the impdu by load segment. NOTE: Load segment 1 always corresponds to the outlet closest to the control unit power cord. Click or in the Segment column to expand or collapse the outlet information. The following information is displayed in column format for each load segment: Severity An icon indicating the status of the load segment ( Normal, Warning, or Critical) Segment # The number of the load segment HP Intelligent PDU web interface 39

40 Outlet # The number of the outlet on an intelligent extension bar (This column is blank if there is no intelligent extension bar connected to the load segment.) UID Indicates if the UID for an extension bar or intelligent extension bar outlet is illuminated (This column is blank if there is no extension bar connected to the load segment. Current (A) The current of the load segment or intelligent extension bar outlet Voltage (V) The voltage of the load segment Load (%) The load percentage of the load segment or intelligent extension bar outlet Power (VA) The apparent power of the load segment Watts (W) The actual power usage of the load segment or intelligent extension bar outlet Power Factor The ratio of the actual power to the apparent power for the load segment or intelligent extension bar outlet Click Refresh to refresh the screen. Click Help to view online help. Control menu Control tab Click Control in the left navigation frame to access the Control screen. This screen contains controls that enable you to issue manual commands. The Control screen contains the following: Control tab (on page 40) Management Processor tab (on page 42) This screen contains controls that enable you to enable or disable outlet control for intelligent extension bars attached to each load segment. If an intelligent extension bar is not attached to a load segment, no information appears on the screen for that load segment. CAUTION: It is highly recommended that browser access to the impdu is isolated from outside access using a firewall or isolated network. The tab name for this screen corresponds to the system name entered on the System Information tab (on page 50). NOTE: Load segment 1 always corresponds to the outlet closest to the control unit power cord. HP Intelligent PDU web interface 40

41 Click or in the Segment column to expand or collapse the outlet information. The following information is displayed in column format for each load segment: Segment The load segment number Outlet The outlet number Outlet Status An icon indicating the status of the outlet (solid green for outlet powered on or solid red for outlet powered off) Outlet Control Indicates if the outlets are controlled by the impdu UID Status Indicates if the UID for an extension bar or intelligent extension bar outlet is illuminated UID Control Indicates UID control functionality for an extension bar or intelligent extension bar outlet Name The name associated with the extension bar or intelligent extension bar outlet (This name is entered on the Device Registration screen ("Device Registration menu" on page 42).) On the Control tab: NOTE: Changes made on this screen that affect the power status require verification on a confirmation popup window. 1. Configure the manual control setting: a. Select Outlet Control in the Setting Control column at the top of the table. Enable The outlets are controlled by the impdu. Disable The outlets are not controlled by the impdu. b. Click Save Settings to save the Outlet Control setting. 2. Perform manual control: a. For each intelligent extension bar outlet, click the On, Off, or Cycle button. On The intelligent extension bar outlet is turned on. HP Intelligent PDU web interface 41

42 Off The intelligent extension bar outlet is turned off. Cycle The intelligent extension bar outlet is turned off for a short period of time and then turned on. b. For each load segment or intelligent extension bar outlet, click the On or Off button. On The appropriate UID is turned on. Off The appropriate UID is turned off. 3. Do one of the following: o o o Click Save Settings to save the information. Click Refresh to refresh the screen. Click Help to view online help. Management Processor tab This screen contains controls that enable you to restart the management processor. To restart the management processor: 1. Click Restart. 2. Confirm the restart on the popup window. Click Help to view online help. Device Registration menu Click Device Registration in the left navigation frame to display the Device Registration screen. This screen contains controls that enable you to record information for devices attached to the impdu load segments and intelligent extension bar outlets, if applicable. NOTE: Load segment 1 always corresponds to the outlet closest to the control unit power cord. HP Intelligent PDU web interface 42

43 Logs tab Click or in the Segment column to expand or collapse the outlet information. On the Device Registration screen: 1. If the Item Selection field is not populated through automatic discovery, select the type of device attached to the load segment. 2. If the UUID field is not populated through automatic discovery, enter the device UUID. 3. If the Device Name field is not populated through automatic discovery, enter a name for the device. IMPORTANT: Before swapping or moving devices or extension bars across load segments, clear the information in the Device Name field. 4. If the Product Name field is not populated through automatic discovery, enter the device product name. 5. If the IP:Port field is not populated through automatic discovery, enter the device IP address. 6. Do one of the following: o Click Save Settings to save the information. o Click Undo Changes to undo the changes. o Click Help to view online help. Menu options listed under the Logs tab include: Event Log menu (on page 44) Application Log menu (on page 45) HP Intelligent PDU web interface 43

44 Event Log menu Click Event Log in the left navigation frame to display the Event Log screen. This screen displays a log of the events that have occurred on the impdu, such as a new intelligent extension bar being attached. The following information is displayed for each event: Severity An icon indicating the severity or status of the event ( Informational, Normal, Warning, or Critical). Description The name of the event Date The date at which the event occurred Time The time at which the event occurred NOTE: When the log reaches the maximum of 500 entries, new entries overwrite the oldest entries in the log. On the Event Log screen: Click Download Event Log to export the event log. The File Download screen appears. o o Click Open to view the log in a user-selected application. Click Save to save the log file (.csv) to your computer. Click Clear Event Log to clear the log files. Click Help to view online help. HP Intelligent PDU web interface 44

45 Application Log menu Click Application Log in the left navigation frame to display the Application Log screen. This screen displays a log of all application events that have occurred, such as a user logging in. The following information is displayed for each application event: User Name The login name of the user who performed the action Hover over the User Name to display the IP address. Description A description of the application event Date The date at which the event occurred Time The time at which the event occurred NOTE: When the log reaches the maximum of 500 entries, new entries overwrite the oldest entries in the log. On the Application Log screen: Click Download Application Log to export the application log. The File Download screen appears. o o Click Open to view the log in a user-selected application. Click Save to save the log file (.csv) to your computer. Click Clear Application Log to clear the log files. Click Help to view online help. Setup tab Menu options listed under the Setup tab include: My Account menu (on page 46) User Accounts menu (on page 47) Network menu (on page 48) HP Intelligent PDU web interface 45

46 Network Management menu (on page 49) PDU Thresholds menu (on page 56) IMPORTANT: When you change the configuration settings using the screens in this section, you might be prompted to reboot the impdu on a popup window. If a reboot is not performed, the changes are not saved. My Account menu Click My Account in the left navigation frame to display the My Account screen. This screen contains controls that enable you to change your login password. To change your password: 1. Enter the new password in the Password field. 2. Enter the new password again in the Verify Password field. 3. Do one of the following: o Click Save Settings to save the new password. o Click Undo Changes to undo the changes. o Click Help to view online help. HP Intelligent PDU web interface 46

47 User Accounts menu Click User Accounts in the left navigation frame to access the User Accounts screen. This screen contains controls that enable administrators to manage user accounts. On the User Accounts screen: Click Undo Changes to undo the changes. Click Help to view online help. To add a user account: 1. Enter the user's sign-in name in the Sign In Name field. 2. Enter the user's password in the Password field. 3. Enter the user's password again in the Verify Password field. 4. If the new user is authorized to change the impdu settings, select the Administrator checkbox. 5. Click Save Settings to save the account information. To modify a user name: 1. Enter the changed name in the Sign In Name field. 2. Enter the user's password in the Password field. 3. Enter the password again in the Verify Password field. 4. If the user has administrator rights added or removed, select or deselect the Administrator checkbox. 5. Click Save Settings to save the updated account information. To modify a user password: 1. Enter the user's login name in the Sign In Name field. 2. Change the password: a. Enter the new password in the Password field. b. Enter the new password again in the Verify Password field. 3. If the user has administrator rights added or removed, select or deselect the Administrator checkbox. 4. Click Save Settings to save the updated account information. HP Intelligent PDU web interface 47

48 To delete a user account: 1. Select the Delete checkbox for the user account that is to be removed. 2. Click Delete Users to delete the user account. The account is removed and no longer appears on the User Accounts screen. Network menu Click Network in the left navigation frame to access the Network screen. This screen contains controls that enable administrators to configure network settings for the impdu. The impdu MAC address is displayed on the Network screen for informational purposes. To configure the network settings: 1. Select a radio button to enable DHCP (IPv4) or Static IP (IPv4). By default, DCHP (IPv4) is enabled. 2. Change the IP address of the impdu. 3. Change the IPv4 network mask of the impdu. 4. Change the IPv4 default gateway of the impdu. NOTE: If you are running the IPv6 network, the IPv6 link local address and auto-configured address are automatically displayed. 5. Enable or disable NTP. Enable NTP to set the date and time automatically. Disable NTP to set the date and time manually. 6. If you enabled NTP in step 5: a. Enter the IP address of the primary NTP server. HP Intelligent PDU web interface 48

49 b. Enter the IP address of the secondary NTP server. c. Select the time zone from the dropdown box. d. Enter the number of hours that should pass between each date and time update. 7. If you disabled NTP in step 5: a. Enter the date. b. Enter the time. c. Select the date format from the dropdown box. 8. To adjust for daylight saving time, select the Enable radio button, and then do the following: a. Enter the month, day, week, and time that daylight saving time starts. b. Enter the month, day, week, and time that daylight saving time ends. c. Select the amount of time the clock changes for daylight saving time in your region. Available options are 30 minutes and 1 hour. 9. Do one of the following: o o o Click Save Settings to save the information. Click Undo Changes to undo the changes. Click Help to view online help. Network Management menu Click Network Management in the left navigation frame to access the Network Management screen. This screen contains controls that enable administrators to configure network management settings for the impdu. The Network Management screen contains the following: System Information tab (on page 50) Trap Receivers tab (on page 51) SNMP Managers tab (on page 52) Setup tab (on page 53) Event Notifications tab (on page 54) Remote Access tab (on page 55) HP Intelligent PDU web interface 49

50 System Information tab This screen contains controls that enable administrators to enter contact information for the impdu. The information entered on this screen appears on the Identification screen ("Identification menu" on page 38). To enter the system information: 1. Enter the name of the impdu in the System Name field. This name appears throughout the interface application and is used in SNMP traps. Use a unique name for each impdu. 2. Enter the name of the contact person in the Contact Name field. 3. Enter the address of the contact person in the Contact field. 4. Enter the phone number of the contact person in the Contact Phone field. 5. Enter the location of the contact person in the Contact Location field. 6. Do one of the following: o o o Click Save Settings to save the information. Click Undo Changes to undo the changes. Click Help to view online help. HP Intelligent PDU web interface 50

51 Trap Receivers tab This screen contains controls that enable administrators to enter information for servers that receive SNMP traps from the impdu. To configure which servers receive traps: 1. Enable SNMP traps for up to 10 servers. 2. Enter the IP address for up to 10 trap recipients in the IP Address field. 3. Enter the community string for each trap recipient. 4. Do one of the following: o o o Click Save Settings to save the information. Click Undo Changes to undo the changes. Click Help to view online help. 5. Click Send Test Trap to send a test SNMP trap. At least one Trap Receiver must be configured and enabled to send a test trap. HP Intelligent PDU web interface 51

52 SNMP Managers tab This screen contains controls that enable administrators to enter information for SNMP managers. SNMP managers are computers that use the HP Power MIB to request information from the impdu. To configure SNMP managers: 1. Enable the SNMP manager configuration for up to five servers. 2. Enter the IP address for each SNMP manager in the IP Address field. IMPORTANT: SNMP managers cannot communicate with the impdu until the IP address is entered on the SNMP Managers tab. Entering the IP address allows SNMP access from any computer. Use a specific IP address for each SNMP manager to avoid compromising the impdu security. 3. Enter the Read community string for each SNMP manager. 4. Enter the Write community string for each SNMP manager. 5. Configure the access type for each SNMP manager. o o RO Read Only RW Read/Write 6. Do one of the following: o Click Save Settings to save the information. o Click Undo Changes to undo the changes. o Click Help to view online help. HP Intelligent PDU web interface 52

53 Setup tab This screen contains controls that enable administrators to configure event notifications. To configure the notifications: 1. Enter the mail server IP address in the Server Address field. 2. Enter the address that messages are marked as being sent from in the From Address field. 3. Select the Enable Account checkbox and enter up to 10 addresses in the Address field. The addresses should correspond to the persons who should receive notifications of events that occur. 4. Do one of the following: o o o Click Save Settings to save the information. Click Undo Changes to undo the changes. Click Help to view online help. 5. Click Send Test to send a test . At least one address must be configured and enabled to send a test . HP Intelligent PDU web interface 53

54 Event Notifications tab This screen contains controls that enable administrators to define the event notifications, s, or SNMP traps the impdu sends for each event. To configure the event notifications: 1. For each event description listed, select the Enabled checkbox to indicate that notifications or SNMP traps are sent for that event. To enable all events, click the checkbox and the SNMP Trap checkbox at the top of each column. 2. For each and SNMP trap enabled, enter the number of minutes that should pass between the occurrence of an alert condition and the sending of the notification. NOTE: If the event clears before the delay time has expired, then the event notification is not sent. 3. Do one of the following: o Click Save Settings to save the information. o Click Undo Changes to undo the changes. o Click Help to view online help. HP Intelligent PDU web interface 54

55 Remote Access tab This screen contains controls that enable administrators to enter information for remote access to the impdu. For more information about security considerations, see "Security considerations overview (on page 85)." For more information about certificates and keys, see "Installing a digital certificate and encryption key for SSL (on page 85)." To configure remote access: 1. Configure web access by doing one of the following: o Select Disable to disable web access. -or- o Select Enable and enter the port number to use HTTPS. Valid port numbers are 1 through The default port is 443. To upload the SSL certificate: i. Open the SSL certificate file with a text editor. ii. Select all content. iii. Copy the selected content. iv. Paste the copied text to the SSL Key field. For more detailed information about uploading the SSL certificate, see "Installing a digital certificate and encryption key for SSL (on page 85)." 2. Configure telnet access by doing one of the following: o o Select Disable to disable telnet access. -or- Enable Telnet Port and enter the port number to use telnet. 3. Configure the session management settings. a. Enable automatic sign-out and enter the number of minutes the impdu should wait before terminating an inactive session. HP Intelligent PDU web interface 55

56 b. Enable retries allowed, enter the number of times a user can unsuccessfully log in to the impdu before the account is locked, and then enter the number of minutes to wait between an unsuccessful login and a new login attempt. 4. Do one of the following: o o o Click Save Settings to save the information. Click Undo Changes to undo the changes. Click Help to view online help. PDU Thresholds menu Click PDU Thresholds in the left navigation frame to access the PDU Thresholds screen. This screen contains controls that enable administrators to configure the warning and critical limits for the impdu load segments. To receive a notification when these limits are met or exceeded, you must configure the impdu to send event notifications. NOTE: Load segment 1 always corresponds to the outlet closest to the control unit power cord. To configure thresholds for the impdu load segments: 1. For each load segment, enter the warning and critical values for total current in percent. 2. Do one of the following: o Click Save Settings to save the information. o Click Undo Changes to undo the changes. o Click Refresh to refresh the screen. o Click Help to view online help. Help tab Menu options listed under the Help tab include: About menu (on page 57) Contents menu (on page 57) Info & Updates menu (on page 58) HP Intelligent PDU web interface 56

57 About menu Click About in the left navigation frame to display the About screen. This screen displays the hardware version, the firmware version, and the MAC address for the impdu, as well as a link to the HP website. Contents menu Click Contents in the left navigation frame to display the Contents screen. This screen provides a list of the links to help topics. HP Intelligent PDU web interface 57

58 Info & Updates menu Click Info & Updates in the left navigation frame to open the HP website. HP Intelligent PDU web interface 58

59 HP Intelligent PDU Service Menu HP Intelligent PDU Service Menu overview The HP Intelligent PDU Service Menu provides an alternative, limited interface to the impdu when the web interface is disabled or not preferred. The menu structure textually displays various measurements and warning and alarm messages from the impdu. Also, system values can be configured through the Service Menu and sent to the impdu. NOTE: All status information and configuration parameters included in the HP Intelligent PDU Service Menu are available using the HP Intelligent PDU web interface (on page 32). Accessing the Service Menu You can access the Service Menu: Remotely through a telnet session (on page 59) Locally through a terminal emulation session (on page 59) using an available serial port Telnet session Use a telnet session to access the HP Intelligent PDU Service Menu: 1. If necessary, configure the impdu: a. Launch a terminal emulation program ("Launching a terminal emulation program" on page 30). b. Configure the impdu remote access settings. 2. Be sure that you have connected the network cable ("Connecting the network cable" on page 29) to the impdu. 3. Launch telnet by entering the following command at a DOS prompt or the command line: Telnet xxx.xxx.xxx.xxx where xxx.xxx.xxx.xxx is the IP address of the impdu. 4. At the prompt, enter the user name and password. The default user name is admin, and the default password is admin. For more information about the Service Menu, see "Service Menu (on page 61)." Terminal emulation session Use a terminal emulation program to access the HP Intelligent PDU Service Menu: 1. Be sure that you have connected the host computer. 2. Launch a terminal emulation program, such as HyperTerminal ("Launching a terminal emulation program" on page 30). HP Intelligent PDU Service Menu 59

60 POST 3. On the session screen, the POST executes, and then a prompt appears. Press any key within 5 seconds to enter the HP Intelligent PDU Service Menu. For more information about the POST, see "POST (on page 60)." For more information about the Service Menu, see "Service Menu (on page 61)." When the impdu is powered up or reset, the bootloader will perform a POST and output the following: If any error is detected in the boot process, the control unit LED indicator illuminates or flashes (on page 68). Navigating the menus After you have successfully initiated a terminal emulation or telnet session, the HP Intelligent PDU Service Menu (on page 61) appears. Open a submenu by entering the corresponding option number at the prompt. To enter or change configuration information, follow the onscreen prompts. Enter 0 at the submenu prompt to go to the previous menu. -or- Enter 0 at the Main menu prompt to exit the utility. Press the Enter key to refresh the screen. The impdu resets automatically to allow configuration changes to take effect. HP Intelligent PDU Service Menu 60

61 Service Menu This menu only appears when accessing the impdu using a terminal emulation program. Option number Submenu Description 1 Module Configuration Opens the HP Intelligent PDU Main menu (on page 61) 2 PDU LED Module Passthrough Bypasses the display unit to allow for direct communication with the impdu 3 Exit Exits the Service Menu and resets the impdu Main menu Option number Submenu Description 1 Network Configuration Enables network configuration for the impdu 2 System Configuration Enables you to set the date, time, and daylight saving time parameters 3 User Accounts Enables you set up and configure user accounts 4 Outlet Control Enables you to disable control of intelligent extension bar outlets 5 My Account Enables you to modify your login account x Exit Without Saving Exits the Service Menu without saving changes s d Save New Changes and Restart Restore Configuration to Manufacturer Settings Saves changes and resets the impdu Restores parameters to default settings Network Configuration submenu Option number Submenu Description 1 IPV4 Network Settings Enables you to enter or change IP version 4 network properties for the impdu 2 IPV6 Network Settings Enables you to enter or change IP version 6 network properties for the impdu 3 Remote Console Enables you to enter or change parameters for telnet access 4 Web Access Configuration Enables you to enter or change parameters for web interface access 5 File Transfer (FTP) Enables or disables the FTP service 6 SNMP Enables you to configure SNMP managers and SNMP traps 7 s Enables you to configure a mail server and event notifications HP Intelligent PDU Service Menu 61

62 Option number Submenu Description 8 Session Settings Enables you to configure timeouts and retries for remote sessions 0 Previous Menu Returns to the previous menu IPV4 Network Settings submenu Option number Submenu Description 1 IPV4 Static Address Enables you to set the impdu IP address 2 IPV4 Static Subnet Mask Enables you to set the impdu subnet mask 3 IPV4 Static Gateway Enables you to set the impdu default gateway 4 IPV4 Toggle Boot Mode Enables you to toggle the boot mode between DCHP and Static IP 5 IPV4 Ping Utility Pings the impdu 0 Previous Menu Returns to the previous menu IPV6 Network Settings submenu Option number Submenu Description 1 IPV6 Gateway Tunnel Enables you to set the impdu gateway tunnel 2 IPV6 Ping Utility Pings the impdu 0 Previous Menu Returns to the previous menu Remote Console submenu Option number Submenu Description 1 Protocol Selection Enables you to select telnet 2 Telnet Configuration Enables you to configure the port for telnet 0 Previous Menu Returns to the previous menu Web Access Configuration submenu Option number Submenu Description 1 Enable/Disable Web Access Enables you to enable or disable web access 2 HTTPS Port Configuration Enables you to configure the port for HTTPS 0 Previous Menu Returns to the previous menu File Transfer (FTP) submenu Option number Submenu Description 1 Enable/Disable service Enables you to enable or disable FTP service 0 Previous Menu Returns to the previous menu HP Intelligent PDU Service Menu 62

63 SNMP submenu Option number Submenu Description 1 SNMP Managers (NMS) Enables you to select an entry to configure the SNMP managers (computers that use the HP Power MIB to request information from the impdu 2 SNMP Traps Enables you to select an entry to configure the SNMP traps receiver 0 Previous Menu Returns to the previous menu SNMP Managers (NMS) submenu Option number Submenu Description 1 IP Address Enables you to enter or change the IP address of the SNMP manager 2 Read Community String Enables you to enter or change the Read community string of the SNMP manager 3 Write Community String Enables you to enter or change the Write community string of the SNMP manager 4 Access Privileges Enables you to enter or change access privileges of the SNMP manager 5 Enable/Disable SNMP Manager Enables you to enable or disable the SNMP manager 0 Previous Menu Returns to the previous menu SNMP Traps submenu Option number Submenu Description 1 Trap Receiver IP Address Enables you to enter or change the IP address of a server that should receive SNMP traps 2 Trap Community String Enables you to enter or change the community strings of a server that should receive SNMP traps 3 Enable/Disable Trap Enables or disables an SNMP traps receiver 0 Previous Menu Returns to the previous menu s submenu Option number Submenu Description 1 Change SMTP Settings Enables you to enter or change SMTP settings in the SMTP Settings submenu (on page 64) 2 Edit An Entry Enables you to edit an recipient entry on the Recipient submenu (on page 64) 0 Previous Menu Returns to the previous menu HP Intelligent PDU Service Menu 63

64 SMTP Settings submenu Option number Submenu Description 1 SMTP Server Enables you to enter or change the mail server IP address 2 Sender Enables you to enter or change the address that messages are marked as being sent from 0 Previous Menu Returns to the previous menu Recipient submenu Option number Submenu Description 1 Receiver Enables you to enter or change an address that should receive alert notifications 2 Enable/Disable Generation Enables or disables the receiver of alert notifications 0 Previous Menu Returns to the previous menu Session Settings submenu Option number Submenu Description 1 Session Inactivity Timeout Enables you to enter the number of minutes the impdu should wait before terminating an inactive session 2 Login Retries Enables you to enter the number of times a user can unsuccessfully log in to the impdu before the account is locked 3 Lock-out Period (After x Retries) 4 Reset Login Retry Count For All Users Enables you to enter the number of minutes to wait between an unsuccessful login and a new login attempt Enables you to reset all locked out sessions 0 Previous Menu Returns to the previous menu System Configuration submenu Option number Submenu Description 1 Date/Time Configuration Enables you to configure the date and time 0 Previous Menu Returns to the previous menu HP Intelligent PDU Service Menu 64

65 Date/Time Configuration submenu Option number Submenu Description 1 Network Time Protocol Enables you to configure the date and time using NTP 2 Manual Date/Time Enables you to configure the date and time manually 3 Daylight Saving Changes Enables you to configure daylight saving time parameters 0 Previous Menu Returns to the previous menu Network Time Protocol submenu Option number Submenu Description 1 Primary NTP Server Enables you to enter or change the IP address of the primary NTP server 2 Secondary NTP Server Enables you to enter or change the IP address of the secondary NTP server 3 GMT Offset (time zone) Enables you to select the time zone from the table provided 4 Update Frequency ( hours) Enables you to enter the number of hours that should pass between each date and time update 5 NTP Client Enables you to enable or disable the NTP client 6 Accept Changes Enables you to save all changes 0 Previous Menu Returns to the previous menu Manual Date/Time submenu Option number Submenu Description 1 Change Date Enables you to enter or change the date manually 2 Change Time Enables you to enter or change the time manually 0 Previous Menu Returns to the previous menu Daylight Saving Changes submenu Option number Submenu Description 1 Enable/Disable Daylight Saving Time Enables you to enable or disable daylight saving time 2 Change Time Offset Enables you to configure the amount of time the clock should change for daylight saving time in your region 3 Change Daylight Saving Time Start Enables you to configure the day and time that daylight saving should start HP Intelligent PDU Service Menu 65

66 Option number Submenu Description 4 Change Daylight Saving Time End Enables you to configure the day and time that daylight saving should end 0 Previous Menu Returns to the previous menu User Accounts submenu Enter the number for the entry you want to modify. The following menus appear. Option number Submenu Description 1 Change User Name Enables you to change a user login name 2 Change Password Enables you to change a user login password 3 Administrator Privilege Enables you to designate a user as an administrator 0 Previous Menu Returns to the previous menu My Account submenu Option number Submenu Description 1 Change User Name Enables you to change your login name 2 Change Password Enables you to change your login password 0 Previous Menu Returns to the previous menu HP Intelligent PDU Service Menu 66

67 Troubleshooting Admin IP address displays incorrectly on the Application Log Symptom: The Application Log displays as the Admin IP address. Action: This is a known issue. No action is required. Browser does not display the web interface Action: 1. Be sure that the IP address and port number are correct. The default port number for secure SSL browser connection is Be sure that the web interface (HTTPS) is enabled on the impdu. Browser incorrectly displays English or Japanese characters Possible Cause: Another user with different language settings logs in to the web interface. Action: Log out of the web interface, close the browser window, and then sign in to the web interface again. Browsing becomes very slow after an alarm is triggered Action: Be sure a valid server is configured on the Setup tab (on page 53). Browsing becomes very slow or stops responding when accessed by multiple Firefox sessions Action: This is a known issue. No action is required. Troubleshooting 67

68 Certificate error Possible Cause: Internet Explorer 7 does not recognize the SSL certificate. Action: Install an SSL certificate that Internet Explorer recognizes. -or- Click Continue to this website (not recommended) to ignore the security warning. Connection closed by remote host error message displays Symptom: While flashing the impdu, the following error message displays: Connection closed by remote host. Action: The firmware might successfully flash, even though this message appears. Verify that the firmware is updated by checking the version number on the About screen ("About menu" on page 57). Control unit LED indicator illuminates or flashes Symptom: The control unit LED indicator is: Troubleshooting 68

69 Permanently on Warning alert Flashing Critical alert Action: Press the Reset button on the control unit. If the problem persists, contact an authorized service provider. The following table lists the error conditions: Test LED flash error code Description 1 Permanently on DRAM failure 2 2 flashes DMA Mem to Mem error 3 3 flashes IRQ error 4 4 flashes Ethernet error 5 5 flashes Serial loop back error 6 6 flashes RTC error Device names display incorrectly Action: Before swapping or moving devices or extension bars across load segments, clear the information in the Device Name field on the Device Registration screen ("Device Registration menu" on page 42). Display unit LED indicator illuminates or flashes Symptom: The display unit LED indicator that is visible when the rack door is closed is: Permanently on Warning alarm Flashing Critical alarm Action: View the Alarms screen ("Alarms menu" on page 38) for more information about the active alarm. Event notification messages do not appear on console screen Action: If you are using SLES 9, upgrade the KDE or use a different desktop, such as GNOME. Event notifications are not being sent Action: While and SNMP trap notifications must be set up on their respective tabs on the Network Management screen, notifications must also be enabled per event on the Event Notifications tab (on page 54). Troubleshooting 69

70 Flash update fails over a serial connection Action: Disable any serial port being configured during the flash update, such as ilo, or use an FTP connection. Help files do not appear Symptom: A Certificate Error: Navigation Blocked warning appears. Action: Click Continue to this website to view the online help. HP SIM lists a discovered impdu as Unmanaged in the System Type column Action: 1. Delete the discovered impdu from HP SIM. 2. Using the impdu web interface, add the HP SIM server as a Manager on the SNMP Managers tab (on page 52). 3. Rediscover the impdu in HP SIM. HPFlash does not install image.bin on a Pentium III Symptom: The image.bin file is not installed on a Pentium III during a serial upgrade. Possible Cause: The minimum hardware requirement for HPFlash is Pentium 4. Action: Be sure that the hardware meets the minimum HPFlash requirements. Invalid IP address Action: Verify that the IP address entered is valid. IPv4 DHCP assigned address is not listed with other network interface parameters Symptom: When the impdu is assigned a DHCP address, the IPv4 address acquired from the network is not listed with other network interface parameters. Possible Cause: The IPv4 address is listed with the hardware parameters. Action: This is a known issue. No action is required. Troubleshooting 70

71 Links in traps and s do not work correctly for Linux Action: Update the /etc/hosts file with the correct IP address. No power Action: Verify that the impdu is connected to a working outlet and that the impdu is powered up. Non-admin users cannot log in through telnet Possible Cause: A user account was added, but the password was not set. Action: An administrator must edit the user account to set a password. Operating system firewall prevents impdu functionality Symptom: The impdu does not connect with the browser. Action: Follow the instructions in the operating system documentation to disable the firewall or to keep the firewall enabled with port 3573 open. Receiving a security error Symptom: Security error: Domain Name mismatch message when trying to browse with SSL. Possible Cause: The IP address or server name has changed. Action: Stop the service, delete the certificate file, and restart the service. Service Menu does not appear on a seriallyconnected host computer Action: 1. Be sure that the serial cable is connected to the correct serial connector on the display unit. 2. Be sure that the serial cable is connected to the correct COM port on the host computer. 3. Reset the impdu while an active terminal emulation session is open. 4. Be sure that the baud rate is set to Troubleshooting 71

72 Unable to obtain a valid network address error message displays Possible Cause: The impdu is unable to connect to the DHCP server. The MAC address for the impdu is not in the DHCP server. A duplicate IP address on the network is detected. Action: 1. Be sure that a DHCP server is on the network. 2. Be sure that the MAC address for the impdu is in the DHCP server. 3. Be sure that the IP address is valid and not in use by another device on the network. Unable to send a test Symptom: An Address Disabled warning appears. Action: Be sure that all addresses entered on the Setup tab (on page 53) are valid and enabled. Unable to set event delays using telnet Action: Event delays must be set using the impdu web interface. User account locked after entering incorrect password Action: Wait for the impdu configured Lockout Time to expire, and then log in using the proper account credentials. Have an administrator reset the Login Retry Count For All Users using the Session Settings submenu option of the HP Intelligent PDU Service Menu. When resetting or powering on the impdu, the browser does not display the web interface Action: Allow 15 to 30 seconds for the impdu to boot. Troubleshooting 72

73 Spares Ordering spares To order a spare, visit the HP website ( To replace parts under warranty, contact an HP authorized service representative. Spare parts list Item Description Spare part number 1 Display unit Single phase, 24 A control unit NA/JPN Single phase, 40 A control unit NA/JPN phase, 24 A control unit NA/JPN phase, 40 A control unit NA/JPN phase, 48 A control unit NA/JPN Single phase, 32 A control unit INTL phase, 16 A control unit INTL phase, 32 A control unit INTL Extension bar Intelligent extension bar Mounting brackets* Spares 73

74 Item Description Spare part number 6 3 m (10 ft) data jumper cord* m (8 ft) data jumper cord* m (6 ft) data jumper cord* m (4.5 ft) data jumper cord* m (12 ft) serial download cable* * not shown Hardware options For information on the supported hardware options, see the HP website ( Spares 74

75 Technical support Before you contact HP Be sure to have the following information available before you call HP: Technical support registration number (if applicable) Product serial number Product model name and number Product identification number Applicable error messages Add-on boards or hardware Third-party hardware or software Operating system type and revision level HP contact information For the name of the nearest HP authorized reseller: See the Contact HP worldwide (in English) webpage ( For HP technical support: In the United States, for contact options see the Contact HP United States webpage ( To contact HP by phone: o o Call HP-INVENT ( ). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. If you have purchased a Care Pack (service upgrade), call For more information about Care Packs, refer to the HP website ( In other locations, see the Contact HP worldwide (in English) webpage ( Technical support 75

76 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product. Federal Communications Commission notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. FCC rating label The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement. Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference Regulatory compliance notices 76

77 to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help. Declaration of conformity for products marked with the FCC logo, United States only This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding this product, contact us by mail or telephone: Hewlett-Packard Company P. O. Box , Mail Stop Houston, Texas HP-INVENT ( ). (For continuous quality improvement, calls may be recorded or monitored.) For questions regarding this FCC declaration, contact us by mail or telephone: Hewlett-Packard Company P. O. Box , Mail Stop Houston, Texas To identify this product, refer to the part, series, or model number found on the product. Modifications Cables The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user s authority to operate the equipment. Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations. Regulatory compliance notices 77

78 Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union regulatory notice Products bearing the CE marking comply with the following EU Directives: Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Ecodesign Directive 2009/125/EC, where applicable CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP. Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website ( (type the product number in the search field). The compliance is indicated by one of the following conformity markings placed on the product: For non-telecommunications products and for EU harmonized telecommunications products, such as Bluetooth within power class below 10mW. For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and!). Please refer to the regulatory label provided on the product. The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger Strasse 140, Boeblingen, GERMANY. Regulatory compliance notices 78

79 Disposal of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Chinese notice Class A equipment Japanese notice Regulatory compliance notices 79

80 Korean notice Class A equipment Class B equipment BSMI notice Regulatory compliance notices 80

81 Alert messages impdu alarms The impdu enables you to send an notification or SNMP trap to specified recipients if a certain alert situation prevails. The following table lists information for all alarm messages. Alarm text Description Default threshold setting Display Communication Error Load Segment Current Critical Load Segment Current Warning Monitored PDU Ext. Bar Communication Error Outlet Communication Error PDU Voltage High Critical PDU Voltage High Warning PDU Voltage Low Critical PDU Voltage Low Warning Phase Load Critical Phase Load Warning Total PDU Load Critical Total PDU Load Warning The display unit can no longer communicate with the impdu. The current for the circuit breaker is above the critical limit. The current for the circuit breaker is above the warning limit. An intelligent extension bar can no longer communicate with the impdu. An outlet device on an intelligent extension bar can no longer communicate with the impdu. The voltage for the impdu is above the critical limit. The voltage for the impdu is above the warning limit. The voltage for the impdu is below the critical limit. The voltage for the impdu is below the warning limit. The phase load is above the critical limit. The phase load is above the warning limit. The total load of the impdu is above the critical limit. The total load of the impdu is above the warning limit. Recommendation - Check the communication link. - Relocate a load to a different load segment. - Consider moving a load to a different load segment. - Check the communication link. - Check the communication link. + 15% rated value Check the impdu input voltage. + 10% rated value Check the impdu input voltage. - 15% rated value Check the impdu input voltage. - 10% rated value Check the impdu input voltage. 90% rated value Balance the loads across all available load segments. 80% rated value Balance the loads across all available load segments. 90% rated value Consider moving a load to a different impdu. 80% rated value Consider moving a load to a different impdu. Alert messages 81

82 Systems Insight Manager integration Systems Insight Manager overview Use HP Systems Insight Manager to: Discover impdus. As part of the discovery process, HP SIM can detect an installed impdu. The web interface for the discovered impdu can be launched from the HP SIM All Systems page. Receive SNMP traps from the impdu. The impdu can send event-based traps to HP SIM that include a URL in the trap. This functionality enables administrators to easily launch the web interface of the impdu in context. For example, if the impdu detects an alarm condition, the impdu can send a trap to HP SIM with an attached hyperlink that routes users directly to the Overview screen for the attached impdu. Conveniently launch the impdu web interface from within HP SIM. o All Systems page All discovered impdus appear on the All Systems page. Click the link in the System Name column to launch a browser session. o Event-based trap A URL is included in each trap to link directly from HP SIM to the Overview screen for the specific device for which the trap was sent. Discovering the impdu HP SIM automatically detects impdus as part of the device discovery process. If detected, a hyperlink is included on the HP SIM All Systems page for the impdu. The impdu should be installed and running before attempting discovery through HP SIM. If the defaults are not used, a new entry can be made to the additionalwsdisc.props file, located in the CONFIG directory in the HP SIM install directory, to allow HP SIM to correctly discover and identify the impdu. For more information on editing the additionalwsdisc.props file, see the additionalwsdisc.txt file located in the same directory. Systems Insight Manager integration 82

83 Example: ADDITIONALWSDISC.PROPS file with impdu entry # # Additional Web Server Discovery Properties # # # NOTE: See "additionalwsdisc_readme.txt" for a description of entries in # this file and how to add or remove additional web server ports used for # discovery and identification. # # # # The following are actual web server ports enabled by default. # To remove them from the discovery process, comment out the line with a '#' # or remove it. You will need to restart the HP SIM service for # the changes to take effect. In addition you will need to run the Device # Identification task to find any new ports that were defined. # =Director Agent,,true,false,,http 3201=Compaq TaskSmart,,true,false,,https 8008=Default Home Page,,true,false,,http 1311=Server Administrator,,true,false,,https 1234=HP impdu,,true,false,,https The last entry allows HP SIM to detect the impdu running on port 1234 and using HTTPS (Secure Socket Layer protocol). HP SIM services must be restarted to apply the change. Configuring HP SIM to receive traps Before HP SIM can receive traps, the correct MIB file (cpqpower.mib) must be compiled into HP SIM. To download the HP Power MIB, visit the HP website ( To register the MIB: 1. Copy the MIB to the HP\Systems Insight Manager\mibs folder. 2. From the HP\Systems Insight Manager\mibs folder, run mcompile cpqpower.mib from the command line to compile the new MIB. A new file named cpqpower.cfg is created. 3. Register the new MIB by entering mxmib -a cpqpower.cfg from the HP\Systems Insight Manager\mibs command line. 4. Enter HP\Systems Insight Manager\mibs>mxmib at the command line and verify that the new MIB is listed. Systems Insight Manager integration 83

84 NOTE: For more information on uploading and registering a MIB in HP SIM, refer to the HP Systems Insight Manager Technical Reference Guide located on the HP Management CD. Configuring the impdu to send traps to HP SIM On the impdu web interface: 1. Click the Setup tab. 2. Click the Network Management menu. 3. Add the HP SIM server as an SNMP trap recipient on the Trap Receivers tab (on page 51). 4. Configure the impdu to send alert notifications to HP SIM on the Event Notifications tab (on page 54). Systems Insight Manager integration 84

85 Security considerations Security considerations overview The impdu implements strict security for two important reasons: The impdu manages devices that have the potential to perform operations that are sensitive and destructive. The impdu has browser accessibility. To better ensure the security of the impdu and the devices it manages, consider the following topics in accordance with your organization's security policies and the environment in which the impdu will operate. Remote access to the impdu requires a user account. Logging in requires the use of a user name and password, which should be kept properly secured. Each account can be given different access levels, providing different capabilities. Ensure that the appropriate access level is granted to users. The web interface is installed behind the firewall. Browsing to the impdu can be done using SSL, which encrypts the data between the browser and impdu. The impdu is supported by a 128-bit encryption level. SSL also provides authentication of the impdu by means of its digital certificate. Securely importing this certificate must be done to ensure the identification of the impdu. Use a custom SSL certificate that is certified by a third-party SSL authority. When a browser logs in to the web interface, other browsers on the system also log in. Consider limiting the time that a browser can be logged in to an account with administrative privileges. Use non-standard ports for the impdu web interface. Disable telnet if remote configuration is not used. Disable the web interface if the web interface is not preferred. Installing a digital certificate and encryption key for SSL The SSL protocol provides for encryption, server and client authentication, and message authentication. To create your own certificate and key for SSL: Linux Many Linux distributions come with pre-compiled OpenSSL packages. Windows A Windows version of OpenSSL can be found at the following website: ( Instructions for creating a self-signed certificate using OpenSSL can be found at the following website: Security considerations 85

86 ( To create your own 512- or 1024-bit SSL certificate and key, you can use the command in the following example: openssl req -x509 -nodes -days 365 -newkey rsa:512 -md5 -keyout mycert.pem -out mycert.pem -text The mycert.pem file includes both a certificate and an encrypted key. NOTE: To prevent a domain mismatch, make sure to enter the host name or IP address of the impdu in the Common Name field when creating a certificate. Since your certificate includes a private key, a pink error heading at the top of your browser. If this occurs, view and install the certificate into your trusted root folder. To copy the certificate to the impdu web server: 1. Log in to the impdu web interface. 2. Click the Setup tab. 3. Click the Network Management menu. 4. Click the Remote Access tab 5. Make sure that web access is enabled and that the HTTPS port is 443 (default) or your preferred HTTPS port number. 6. Paste the certificate (contents of the mycert.pem file) in the SSL Key field. The key must be in the following format: -----BEGIN RSA PRIVATE KEY key contents END RSA PRIVATE KEY----- Certificate: Data: BEGIN CERTIFICATE certificate contents END CERTIFICATE Click Save Settings. 8. Click OK on the reboot prompt. 9. Allow the impdu to reboot. 10. Change the URL used to access the web interface to HTTPS. Security considerations 86

87 Optional power monitoring using SNMP SNMP monitoring The impdu status, events, and traps can be monitored using third-party SNMP managers. SNMP monitoring supports the RFC-1628 MIB and the HP Power MIB (CPQPOWER.MIB). To configure SNMP monitoring: 1. Using the SNMP Managers tab (on page 52), configure the third-party SNMP manager to monitor the impdu. 2. Using the third-party SNMP manager software, configure the impdu information to be monitored by the SNMP manager. The HP Power MIB (CPQPOWER.MIB) can be downloaded from the HP website ( Optional power monitoring using SNMP 87

88 Updating the firmware Updating the firmware overview The HP Flash Utility is a universal tool used to flash firmware (image.bin) or replicate the configuration settings (config.bin) for the impdu. The HP Flash Utility supports two different transfer modes: Serial Flash Mode (firmware) o Single unit FTP Flash Mode (firmware and configuration settings) o Single unit o Multiple units Serial Flash Mode To update the impdu firmware serially: 1. Be sure that you have connected a serial cable to the display unit and the host computer. 2. Set the impdu to LED Pass-Through mode: a. Launch a terminal emulation program, such as HyperTerminal ("Launching a terminal emulation program" on page 30). Updating the firmware 88

89 b. Press the Reset button on either the display unit or the control unit. On the terminal emulation session screen running on the host computer, the POST executes, and the following prompt appears: Press any key in 5 seconds to enter the Service menu. c. Press a key to enter the HP Intelligent PDU Service Menu (on page 61). d. On the Service Menu, enter 2 at the prompt to select PDU LED Pass-through. e. Enter 3 at the prompt to exit the Service Menu. f. After the > prompt appears, close the terminal emulation program. 3. Launch the HP Flash Utility. 4. Select Serial as the transfer mode. 5. Select Image.bin as the file type. 6. Click the Browse button (...) to navigate to a saved image.bin file. 7. Select the COM port of the host computer. 8. Click Flash. FTP Flash Mode To update the firmware for a single impdu: 1. Be sure that the impdu is connected to the network. 2. Note the IP address of the impdu. 3. Launch the HP Flash Utility. 4. Select FTP as the transfer mode. 5. Select Image.bin as the file type to flash the firmware. 6. Click the Browse button (...) to navigate to a saved image.bin file. 7. Enter the impdu IP address, then click >> to add the IP address to the table. To remove IP addresses from the table, highlight the unwanted IP addresses, and then click X. 8. Click Ping to verify that the IP address is valid. If a good connection is detected, the Flash button enables 9. Enter your username and password. 10. Click Flash. To update the firmware for multiple impdus: 1. Be sure that all impdus are connected to the network. 2. Note the IP address of each impdu. 3. Launch the HP Flash Utility. 4. Select FTP as the transfer mode. 5. Select Image.bin as the file type to flash the firmware. 6. Click the Browse button (...) to navigate to a saved image.bin file. 7. Enter the IP address for each impdu. Click >> to add each IP address to the table. To remove IP addresses from the table, highlight the unwanted IP addresses, and then click X. Updating the firmware 89

90 NOTE: IP address entries in the table are automatically saved to the text file FTPIPDetails.txt. Click Load IPs to load IP addresses from the file. 8. Click Ping to verify that all IP addresses are valid. If good connections are detected, the Flash button enables. Check the Flash Status field for any IP addresses that failed to PING. Make the necessary corrections, or these IP address are skipped during the flashing process. 9. Click Flash. The operation cannot be interrupted. Updating the firmware 90

91 SNMP trap codes SNMP trap codes This information is for reference only. SNMP trap code SNMP trap message 0 Test Trap 1 PDU Voltage High Critical 2 PDU Voltage Low Critical 3 Total PDU Load Critical 4 Phase Load Critical 5 Load Segment Current Critical 6 PDU Voltage High Warning 7 PDU Voltage Low Warning 8 Total PDU Load Warning 9 Phase Load Warning 10 Load Segment Current Warning 11 Monitored PDU Ext. Bar Communication Error 12 Display Communication Error 13 Outlet Communication Error 14 Monitored PDU Ext. Bar Connected 15 Monitored PDU Ext. Bar Disconnected 16 Display Connected 17 Display Disconnected 18 Outlet Communication Link Connected 19 Outlet Communication Link Disconnected SNMP trap codes 91

92 Application recovery Recovering a corrupted application Use a terminal emulation session to recover the application using TFTP. If the main application and the backup application are corrupt, the following screen appears: To recover the application: 1. Enter 1 to select TFTP Upgrade. 2. Enter a temporary MAC address. 3. Enter an IP address that you can access using a host computer running a TFTPD server. 4. Enter the subnet mask. 5. Enter the TFTPD server IP address. HP recommends using the TFTPD server available at ( 6. Be sure that the image.bin file is in the current directory, and then confirm the download. The file is flashed. 7. When prompted, press Enter to reboot. After rebooting, the application is recovered. Application recovery 92

HPE Intelligent Power Distribution Unit Installation Instructions

HPE Intelligent Power Distribution Unit Installation Instructions HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for

More information

HPE Intelligent Power Distribution Unit User Guide

HPE Intelligent Power Distribution Unit User Guide HPE Intelligent Power Distribution Unit User Guide Abstract This document includes installation, configuration, and operation information for the HPE Intelligent Power Distribution Unit. This document

More information

HPE UPS Network Module User Guide

HPE UPS Network Module User Guide HPE UPS Network Module User Guide Abstract This document includes installation, configuration, and operation information for the HPE UPS Network Module. This document is for the person who installs and

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Switched Rack Power Distribution Unit

Switched Rack Power Distribution Unit Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

Installing and Managing the Switch

Installing and Managing the Switch CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

HPE UPS R5000 User Guide

HPE UPS R5000 User Guide HPE UPS R5000 User Guide Abstract This document includes installation, configuration, and operation information for the HPE UPS R5000. This document is for the person who installs and maintains power products.

More information

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install HP Proliant DL360 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: COOPE-RRTF1 Published: September 2010 Edition: 1 Copyright 2010 Hewlett-Packard Development Company,

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....

More information

HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide

HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide Abstract This guide provides information on using the HP BladeSystem Management Pack for System Center version 1.x to manage

More information

HP Uninterruptible Power Supplies Overview

HP Uninterruptible Power Supplies Overview NOTE: Additional information on these and additional HP UPS products at: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html Description HP rack mountable UPSs, designed

More information

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version

More information

HP R/T3000 G2 UPS User Guide

HP R/T3000 G2 UPS User Guide HP R/T3000 G2 UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R/T3000 G2 UPS. This document is for the person who installs and maintains

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,

More information

QuickSpecs HP Power Manager 4.2

QuickSpecs HP Power Manager 4.2 Overview HP Power Manager is a web-based application that enables administrators to manage an HP UPS from a browser-based management console. Administrators can monitor, manage, and control a single UPS

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

G5 PDU Installation Guide

G5 PDU Installation Guide G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form

More information

HPE ilo Federation User Guide for ilo 5

HPE ilo Federation User Guide for ilo 5 HPE ilo Federation User Guide for ilo 5 Abstract This guide explains how to configure and use the HPE ilo Federation features. It is intended for system administrators, Hewlett Packard Enterprise representatives,

More information

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks) Overview The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single

More information

HP UPS R5500 User Guide

HP UPS R5500 User Guide HP UPS R5500 User Guide Part Number 351643-004A September 2007 (Fourth Edition) Copyright 2003, 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

More information

HP integrated Citrix XenServer Online Help

HP integrated Citrix XenServer Online Help HP integrated Citrix XenServer Online Help Part Number 486855-002 September 2008 (Second Edition) Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to

More information

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5 User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 6. Specifications... 8 1. Introduction The ServerLink PDU is a network

More information

HP Intelligent Management Center Remote Site Management User Guide

HP Intelligent Management Center Remote Site Management User Guide HP Intelligent Management Center Remote Site Management User Guide Abstract This book provides overview and procedural information for Remote Site Management, an add-on service module to the Intelligent

More information

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview QuickSpecs Overview (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to make the most of circuit capacity

More information

HP BladeSystem c-class Enclosure Troubleshooting Guide

HP BladeSystem c-class Enclosure Troubleshooting Guide HP BladeSystem c-class Enclosure Troubleshooting Guide Part Number 460224-002 July 2009 (Second Edition) Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA 25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m

More information

HP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition)

HP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition) HP BIOS Serial Console User Guide Part Number 306147-002 March 2003 (Second Edition) 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.

More information

HP Server Console Switch with Virtual Media User Guide

HP Server Console Switch with Virtual Media User Guide HP Server Console Switch with Virtual Media User Guide Part Number 409048-003 August 2008 (Third Edition) Copyright 2006, 2008 Hewlett-Packard Development Company, L.P. The information contained herein

More information

- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units. - 1 - Release Notes for Dominion PX Software Version 1.2.7 (firmware version will be displayed as 01.02.07 in the GUI after an upgrade) Version: DPX 1.2.7 Release Notes, Revision 1.3 Date: January 7, 2009

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching

More information

HPE PSR300-12A & PSR300-12D1

HPE PSR300-12A & PSR300-12D1 HPE PSR300-12A & PSR300-12D1 Power Supplies User Guide 5998-1604s Part number: 5998-1604s Document version: 6PW103-20160405 Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information

More information

HP Management Integration Framework 1.7

HP Management Integration Framework 1.7 HP Management Integration Framework 1.7 Administrator Guide Abstract This document describes the use of HP Management Integration Framework interfaces and is intended for administrators involved in the

More information

User Manual. Per Port Monitoring Models

User Manual. Per Port Monitoring Models User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port

More information

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES www.unipowerco.com Manual No. PDUAC1USM-2 pduac1us-man-rev2-0115.indd 2015 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive,

More information

ReadyNAS OS 6 Rack-Mount Hardware Manual

ReadyNAS OS 6 Rack-Mount Hardware Manual Rack-Mount Hardware Manual Model ReadyNAS 2120 ReadyNAS 2120 v2 ReadyNAS 3130 ReadyNAS 3138 ReadyNAS 3220 ReadyNAS 3312 ReadyNAS 4220 ReadyNAS 4312 ReadyNAS 4360 April 2017 202-11272-08 350 E. Plumeria

More information

HPE Intelligent Management Center

HPE Intelligent Management Center HPE Intelligent Management Center Service Health Manager Administrator Guide Abstract This guide provides introductory, configuration, and usage information for Service Health Manager (SHM). It is for

More information

ilo Amplifier Pack User Guide

ilo Amplifier Pack User Guide ilo Amplifier Pack User Guide Abstract This guide provides information about installing, configuring, and operating ilo Amplifier Pack. Part Number: P04465-001 Published: December 2017 Edition: 4 Copyright

More information

Power distribution solutions for the ProLiant DL580 G2 server

Power distribution solutions for the ProLiant DL580 G2 server Power distribution solutions for the ProLiant DL580 G2 server Introduction... 2 Symbols in text... 2 Executive summary... 2 Glossary... 2 ProLiant DL580 G2 server power requirements... 3 Power distribution

More information

H3C SecBlade SSL VPN Card

H3C SecBlade SSL VPN Card H3C SecBlade SSL VPN Card Super Administrator Web Configuration Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document version: 5PW105-20130801 Copyright 2003-2013, Hangzhou H3C Technologies

More information

QUICK SETUP GUIDE. Raritan PXE. Safety Precautions. Before You Begin. Mounting the PDU. Unpacking the PXE. 1U Size

QUICK SETUP GUIDE. Raritan PXE. Safety Precautions. Before You Begin. Mounting the PDU. Unpacking the PXE. 1U Size QUICK SETUP GUIDE Raritan PXE Thank you for purchasing the Raritan PXE intelligent power distribution unit (PDU). The intended use of the PXE is distribution of power to information technology equipment

More information

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased

More information

KMnet Viewer. User Guide

KMnet Viewer. User Guide KMnet Viewer User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We cannot be

More information

For details on using the LX, access online help from the application, or download help in PDF format from the Support page on Raritan's website.

For details on using the LX, access online help from the application, or download help in PDF format from the Support page on Raritan's website. Dominion LX Quick Setup Guide Thank you for your purchase of the Dominion LX. The LX is the industry's highest quality, most affordable digital KVM (Keyboard, Video, Mouse) switch for your growing SMB

More information

ECO PDU Power Distribution Unit

ECO PDU Power Distribution Unit ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your

More information

Installation and Configuration Guide

Installation and Configuration Guide CYBERSECURITY, EVOLVED EdgeWave iprism Web Security Installation and Configuration Guide V8.0 15333 Avenue of Science, Suite 100 San Diego, CA 92128 Give us a call 1-855-881-2004 Send us an email: info@edgewave.com

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide

HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide Abstract This document explains how to install and use the HPE StoreEver MSL6480 Tape Library CLI utility, which provides a non-graphical

More information

Management and Printing User Guide

Management and Printing User Guide Management and Printing User Guide Copyright 2007 Hewlett-Packard Development Company, L.P. Windows is a U. S. registered trademark of Microsoft Corporation. Intel and Centrino are trademarks or registered

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m Dell Network Management Card User's Guide w w w. d e l l. c o m s u p p o r t. d e l l. c o m Notes and Warnings NOTE: A NOTE indicates important information that helps you make better use of your software.

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide h-series 800-782-3762 www.edgewave.com 2001 2011 EdgeWave Inc. (formerly St. Bernard Software). All rights reserved. The EdgeWave logo, iprism and iguard are trademarks

More information

HPE Apollo Platform Manager User Guide

HPE Apollo Platform Manager User Guide HPE Apollo Platform Manager User Guide Abstract This guide provides installation and operation guidance for the HPE Apollo Platform Manager. This guide is for the person who installs, administers, and

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

Raritan PXE. Quick Setup Guide. Safety Precautions. Before You Begin. Mounting the PXE. Unpacking the PXE. Zero U Size. 1U Size

Raritan PXE. Quick Setup Guide. Safety Precautions. Before You Begin. Mounting the PXE. Unpacking the PXE. Zero U Size. 1U Size Raritan PXE Quick Setup Guide Thank you for purchasing the Raritan PXE intelligent power distribution unit (PDU). The intended use of the PXE is distribution of power to information technology equipment

More information

Codian IP VCR IP VCR 2200 Series

Codian IP VCR IP VCR 2200 Series Codian IP VCR IP VCR 2200 Series Getting Started Codian IP VCR IP VCR 2200 Series Getting Started Copyright Codian 2006. All rights reserved. This Getting Started Guide may not be copied, photocopied,

More information

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview Overview HP Basic PDUs are designed to provide reliable and cost effective power distribution for your HP and non-hp IT racks. Offering simple 0U and 1U installation options, HP Basic PDUs are available

More information

1. General Description

1. General Description ipio-2, ipio-8, ipio-16 Monitor and Control of Digital I/O 1. General Description The ipio is a network attached, web enabled digital input and output device. The ipio can be controlled and monitored with

More information

HP Insight Remote Support Advanced HP StorageWorks P4000 Storage System

HP Insight Remote Support Advanced HP StorageWorks P4000 Storage System HP Insight Remote Support Advanced HP StorageWorks P4000 Storage System Migration Guide HP Part Number: 5900-1089 Published: August 2010, Edition 1 Copyright 2010 Hewlett-Packard Development Company, L.P.

More information

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4 User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed

More information

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your

More information

Manual Version: V1.00. Video Decoder User Manual

Manual Version: V1.00. Video Decoder User Manual Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

QuickSpecs HP T750 UPS. Overview

QuickSpecs HP T750 UPS. Overview Overview Rated at 750 VA/500 Watts, the features a unique design and easy-to-configure front panel display. Ideal for desktop, workstation, or entry-level server environments, this Uninterruptible Power

More information

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline VERTIV RPC2 Communications Module Release Notes FIRMWARE VERSION 12.0.0.5_00109, SEPTEMBER 8, 2017 Release Notes Section Outline 1 Version and Compatibility Information 2 Features and Enhancements 3 Upgrade

More information

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place

More information

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HPE VMware ESXi and vsphere. Part Number: 818330-003 Published: April

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes HP BladeSystem c-class Virtual Connect Support Utility Version 1.9.1 Release Notes Abstract This document provides release information for the HP BladeSystem c-class Virtual Connect Support Utility Version

More information

VTRAK E-Class/J-Class Quick Start Guide

VTRAK E-Class/J-Class Quick Start Guide VTRAK E-Class/J-Class Quick Start Guide Version.0 Firmware 3.9 008 Promise Technology, Inc. All Rights Reserved. VTrak Quick Start Guide About This Guide This Quick Start Guide shows you how to install

More information

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi and vsphere. HP Part Number: 616896-409 Published: September

More information

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline VERTIV RPC2 Communications Module Release Notes FIRMWARE VERSION 14.0.0.3_00290, AUGUST 3, 2018 Release Notes Section Outline 1 Version and Compatibility Information 2 Features and Enhancements 3 Upgrade

More information

HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide

HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide Abstract This guide provides information about developing encryption key management processes, configuring the tape autoloader

More information

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5

More information

Troubleshooting. User Guide

Troubleshooting. User Guide Troubleshooting User Guide Copyright 2006 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. The information contained herein is subject

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,

More information

HP Load Balancing Module

HP Load Balancing Module HP Load Balancing Module System Management Configuration Guide Part number: 5998-4216 Software version: Feature 3221 Document version: 6PW100-20130326 Legal and notice information Copyright 2013 Hewlett-Packard

More information

HP SmartTracker. User Guide

HP SmartTracker. User Guide HP SmartTracker User Guide 2018 HP Development Company, L.P. Edition 3 Legal notices The information contained herein is subject to change without notice. The only warranties for HP Products and services

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Intelligent Provisioning 3.00 Release Notes

Intelligent Provisioning 3.00 Release Notes Intelligent Provisioning 3.00 Release Notes Part Number: 881705-001b Published: October 2017 Edition: 3 Copyright 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein

More information

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information HP LaserJet MFP Analog Fax Accessory 300 Supplemental Information HP LaserJet MFP Analog Fax Accessory 300 Supplemental Information Copyright Information 2005 Copyright Hewlett-Packard Development Company,

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

WTI Part No Rev. H. VMR Series. Managed Power Controllers. NPS Series. Network Power Switches. User's Guide

WTI Part No Rev. H. VMR Series. Managed Power Controllers. NPS Series. Network Power Switches. User's Guide WTI Part No. 14102 Rev. H VMR Series Managed Power Controllers NPS Series Network Power Switches User's Guide Warnings and Cautions: Installation Instructions Secure Racking If Secure Racked units are

More information

Silex SD-320AN-03 Serial Server

Silex SD-320AN-03 Serial Server GE Healthcare Silex SD-320AN-03 Serial Server Firmware Upgrade Instructions 2106794-001 Revision B Silex SD-320AN-03 Serial Server English 2018 General Electric Company. All Rights Reserved. Publication

More information

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes Part Number: 732171-007 Published: February 2017 Edition: 1 2017 Hewlett Packard Enterprise Development LP Notices The information contained

More information

Aruba JL311A Cable Guard Installation Instructions

Aruba JL311A Cable Guard Installation Instructions Aruba JL3A Cable Guard Installation Instructions Abstract Use this guide to assist in the basic installation of the Aruba JL3A Cable Guard on select Aruba 8 port switches. *500-97* Part Number: 500-97

More information

HP Accelerated iscsi for Multifunction Network Adapters User Guide

HP Accelerated iscsi for Multifunction Network Adapters User Guide HP Accelerated iscsi for Multifunction Network Adapters User Guide Part Number 410538-00J December 2007 (Ninth Edition) Copyright 2006, 2007 Hewlett-Packard Development Company, L.P. The information contained

More information

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:

More information

HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide

HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide Abstract This guide is for HPE StoreOnce System Administrators. It assumes that the user has followed the instructions

More information

NETWORK PRINT MONITOR User Guide

NETWORK PRINT MONITOR User Guide NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We

More information

Cisco TelePresence Video Communication Server. Getting started

Cisco TelePresence Video Communication Server. Getting started Cisco TelePresence Video Communication Server Getting started D14350.04 November 2010 Contents Contents Contents 2 General information 3 About the Cisco TelePresence Video Communication Server (Cisco VCS)

More information