s SINUMERIK 840D sl

Size: px
Start display at page:

Download "s SINUMERIK 840D sl"

Transcription

1 s SINUMERIK 840D sl ShpTurn 1.5 SP2 SINUMERIK 840D sl, CNC SOFTWARE 6-3 ) 6FC5842-1XG11-0YA0 with ShpTurn HMI, in 6 languages (EN,DE,FR,IT,SP,V-CH), n CF card; with license ) Exprt 6FC5842-1YG11-0YA0 SINUMERIK 840D sl, CNC SOFTWARE 31-5 ) 6FC5842-3XG11-0YA0 with ShpTurn HMI, in 6 languages (EN,DE,FR,IT,SP,V-CH), n CF card; with license ) Exprt 6FC5842-3YG11-0YA0 SINUMERIK 840D sl, CNC SOFTWARE 6-3/31-5 ) 6FC5842-3XC11-0YA8 with ShpTurn, in 6 languages (EN,DE,FR,IT,SP,V-CH), n DVD; withut license ) Exprt 6FC5842-3YC11-0YA8 Infrmatin abut installing and perating the sftware n SINUMERIK NCU 710.1, NCU 710.2, NCU 720.1, NCU 720.2, NCU 730.1, NCU The NCU sftware 1.5 SP2 (internal versin ) cnsists f the fllwing cmpnents: LinuxBase (NCU) V NCK Sftware V PLC OpSys V (PLC 317) PLC-FB15 V CP V MCP Client V SINAMICS Sftware V ShpTurn HMI-Embedded V Technlgy Cycles V Measuring Cycles V Cycles ISO Cmpatibility V Adapting Cycles V Installing the NCU sftware: Fr installing the NCU sftware yu will need the NCU service system V r higher n USB stick. New installatin can nly be perfrmed either using the NCU Service System and TCU with keybard r WinSCP. New installatins withut full keybard r WinSCP can nly be perfrmed using an USB stick which has been prepared fr autmatic upgrade (cf. General infrmatin). The sftware may nly be installed n a SanDisk CmpactFlash GB. MLFB / rder n. fr the empty card: 6FC5313-5AG00-0AA Installing the NCU service systems n USB stick: The NCU service system is lcated as a USB stick image in the emergency_btsys_ncu directry n the supplied DVD. The installdisk.exe cpy rutine is lcated in the same lcatin. Cnnect a 512MB r 1GB USB stick, recmmended type Siemens 6ES7648-0DCx0-0AA0, t yur prgrammer ("PG") r PC (with Windws XP) and nte dwn the letter f the drive t which the stick is cnnected. Run the installdisk rutine t cpy the NCU service system t the USB stick: installdisk --verbse --blcksize 1m <image file> <drive letter:> Example: ( -- means 2x minus sign) installdisk --verbse --blcksize 1m D:\ emergency_btsys_ncu\linuxbase-512m.img X: r Siemens AG 2008 I DT R&D 51 Page 1 f 33

2 ShpTurn 1.5 SP2 installdisk --verbse --blcksize 1m D:\ emergency_btsys_ncu\linuxbase-resize.img X: (When using the...resize.img, bt the NCU nce frm USB stick in rder t unpack the image n the stick). It is best t cpy the image in a DOS shell. T this end, yu will need administratr rights n yur PG/PC. After cmpletin f installdisk, remve the USB stick frm yur PG / PC and insert it again. Under Windws, yu will nw see an empty USB stick. Nw cpy the desired NCU sftware (file with ".tgz extensin) frm the supplied DVD, ncu_sw directry t yur USB stick. Yu may insert the USB stick int ne f the tw USB prts n the NCU 7x0. When the NCU is turned n, it will bt frm this USB stick. The peratin is always perfrmed via a TCU cnnected t the NCU, r via PG / PC using WinSCP with "Open Terminal". Fr a descriptin f the peratin f the NCU service system, please refer t the /IM7/ Dcumentatin n the supplied DVD. 1.2 Upgrading an NCU 7x0 with NCU sftware, versin 1.5 and higher With an upgrade, all user data n the CF card in the directries /user, /addn, /em, and the license key are maintained. Fr the upgrade f systems equipped with several NCUs / PCU50, please refer t Sectin 7 "Netwrking". Bt the NCU frm yur USB stick (see 1.1). Select the Service Shell using F2 / F3. Lg in with user name "manufact". This may require an external keybard, since user names must be written in lwer case letters. Enter the fllwing cmmand after the peratr prmpt $ in the service shell: sc restre -update /data/<ncu-sw>.tgz The sftware update is cmpleted when prmpt $ is displayed again. Remve the USB stick. Bt the NCU (Pwer ON / OFF). Nw yu can start up the PLC, drives and NC Upgrade using WinSCP Systems withut TCU at the NCU can be upgraded with WinSCP, fr example n a PCU 50. Fr this purpse, lg n at the NCU with WinSCP as "manufact" and cpy the required NCU sftware (file with extensin.tgz) frm the ncu_sw directry n the supplied DVD t /card/user/system/hme/manufact n the NCU. Then enter the fllwing cmmand under "Cmmands / Open Terminal": sc restre -update -frce <ncu-sw>.tgz The sftware is installed when the "Syncing disks... dne" message is displayed. Afterwards, the NCU must be rebted. The <ncu-sw>.tgz file n the NCU shuld be deleted. Nte: During the installatin, messages may be displayed claiming that the cmmunicatin partner has nt reacted fr sme time. Yu can ignre these messages, but please d nt cut the cnnectin in this case. 1.3 New installatin n CmpactFlash card r upgrade frm SW 1.3, SW 1.4 nt Sftware Versin 1.5 IMPORTANT: This prcedure cmpletely deletes anything existing n the CmpactFlash Card; this applies t an empty CmpactFlash Card as well. Bt the NCU frm yur USB stick (see 1.1). Select the Service Shell using F2 / F3. Lg in with user name "manufact"; when the CmpactFlash Card is empty; use "admin", passwrd "SUNRISE" instead. This may require an external keybard, since user names must be written in lwer case letters. Enter the fllwing cmmand after the peratr prmpt $ in the service shell: sc restre -full /data/<ncu-sw>.tgz The sftware update is cmpleted when prmpt $ is displayed again. Remve the USB stick. Bt the NCU (Pwer ON / OFF). When the system is started with TCU(s) fr the first time, the TCU(s) must be lgged n t the system. Siemens AG 2008 I DT R&D 51 Page 2 f 33

3 ShpTurn 1.5 SP2 Enter the TCU name (default TCUx) and the address f an assigned MCP. Nw yu can start up the PLC, drives and NC. 1.4 Systems withut TCU If, fr the sftware installatin crrespnding t 1.2 r 1.3 there is n OP with TCU available t perate the NCU- Service System, then peratr cntrl is als pssible frm the PCU50 r PC/PG using the WinSCP (Cmmands / Open Terminal) r VNC viewer. Under certain circumstances, it is nt pssible t install the sftware withut NCU Service System n the USB stick as there is nt enugh free memry space n the CF card. 1.5 Autmatic upgrade using a bt-capable USB stick: Using an apprpriately prepared USB stick >= 1GB, it is pssible t perfrm an autmatic restre update r restre full. T d this, a script (autexec.sh) and the NCU sftware must be cpied nt the stick. The name f the script must nt be changed. The NCU sftware cpied t the stick must be renamed as either update.tgz r full.tgz. The SIM/NCK rtary switch n the NCU must then be set t psitin 7 and the NCU bted frm the stick. The script nw nly runs when the rtary switch is in the 7 psitin. Otherwise, the system is bted frm the stick and a branch is made int the service menu. Frm the NCU sftware designatin, the script decides whether a restre update r a restre full is perfrmed. In additin, befre the restre peratin, the script backs up the data n the CF card. The prgress f the individual script steps can be tracked n the 7-segment display r als n the internal HMI. The precise significance f the displays and the individual steps are described in a separate dcument. The script is included n the DVD supplied. 2. New functins in NCK (r later) The machine manufacturer can set in machine data $MN_ASUP_EDITABLE whether the Siemens System ASUP frm _N_CST_DIR r a user ASUP frm _N_CUS_DIR (_N_CMA_DIR) shall be executed with RET r REPOS events. ET200S-F I/Os are supprted fr Safety Integrated. GETFREELOC can be called up several times during empty lcatin search in the tl management. The machine data $MA_JOG_AND_POS_MAX_JERK[axis] is nw active with NEWCONF. The cuplings TRAIL, LEAD and ELG are implemented fr (BCS) and (MCS). Fixed-pint apprach in JOG: Max. fur fixed pints can be defined via the machine data $MA_FIX_POINT_POS[]. The number f valid fixed pints is determined via the machine data $MA_NUM_FIX_POINT_POS. Apprach prcedure: - Select JOG mde - Activate via PLC interface (see 4.3) - Traverse axis using axis key (cntinuus resp. incremental) r handwheel until it stps autmatically. The axis stps at the defined fixed pint withut emitting an alarm message. The number f pssible parameterizable transfrmatins has been extended frm 10 t 20. Generic transfrmatin has been extended t include a 7th axis. The nesting depth f subprgrams and cntrl structures has been increased frm 8 t 16. The current axial setpint and actual braking path can be read using system variables. Basic crdinate system: $AA_DTBREB[AX] Ttal braking path $AA_DTBREB_CMD[AX] Path single interplatr $AA_DTBREB_CORR[AX] Overlaid mvements $AA_DTBREB_DEP[AX] Cupled axis Machine crdinate system: $AA_DTBREM[AX] $AA_DTBREM_CMD[AX] $AA_DTBREM_CORR[AX] $AA_DTBREM_DEP[AX] The number f safe cams (SN) has been increased t 30 with slutin line. Siemens AG 2008 I DT R&D 51 Page 3 f 33

4 ShpTurn 1.5 SP2 Empty lcatin search within turret magazines can be perfrmed using the same setting ptins as fr chain magazines. The prgram attribute ACTBLOCNO is used t utput the blck number frm the current blck cntaining the alarm upn alarm utput with active DISPLOF. Machine data $mc_ign_prg_state_asup defines whether the display f the ASUP name shall be suppressed. The ASUP is perfrmed silently. The functin Any Asup Active sets the new channel-specific VDI signal anyasupactive in DB.[channel].DBX The new channel-specific VDI signal silentasupactive is set in DB.[channel].DBX378 if an ASUP is perfrmed silently. Interruptability f ASUPs: Certain Prg-Events shall nt be prevented r stpped by VDI signal NC Stp DB[channel].DBX 7.3). This ensures that the Prg-Event is executed cmpletely independently f the VDI signal. The VDI signals NC Stp at the blck end DB[channel].DBX 7.2, NC Stp Axes plus spindle DB[channel].DBX 7.4 are discarded accrdingly. The functin is activated by the bit-cded machine data $MC_PROG_EVENT_IGN_STOP fr any Prg-Events. The subprgram return RET(...) allws yu t return t a blck number r label f the calling prgram. This functin has been extended such that yu can als specify any string as return target. Time mnitring n synchrnus spindles: When reaching setpint-side synchrnizatin, tw time windws are initialized which are used t mnitr the time span until actual value-side carse resp. fine synchrnizatin is reached. The size f the time windws is taken frm MD $MA_COUP_SYNC_DELAY_TIME[0/1]. Index 0 fr fine synchrnizatin and Index 1 fr carse synchrnizatin. The value f zer deactivates the respective mnitring mde. If actual value-side carse/fine synchrnizatin is nt reached befre the relevant time windw has expired, Alarm is utput. 3. General infrmatin: After the new installatin f NCU sftware 1.5 n a CmpactFlash card, a general reset f the NCU and PLC must be perfrmed: Turn the SIM / NCK switch t psitin 1, the PLC switch t psitin 3 and perfrm a POWER ON. NCU710 / NCU720: The PLC prgram must initiate an immediate (apprx. 20 secs) reactin t alarm "2120 NCK fan alarm" by stpping the axes in a cntrlled manner. NCU730: The PLC prgram must initiate an immediate (apprx. 20 secs) reactin t alarm "2120 NCK fan alarm" by stpping the axes in a cntrlled manner if n duble-fan mdule is used. NCU710 / NCU720: The NCU will nt pwer up if a fan mdule is nt installed r if the fan is defective. This applies fr NCU 730 with duble fan mdule nly in the case f failure f bth fans. Alarm "%1 data have been restred, f which %2 machine data, %3 errr" If %3 indicates that mre than zer errrs have ccurred, it is nt advisable t cntinue wrking with the data. T avid further prblems, yu shuld read in an up-t-date backup cpy f the data. It is nt always pssible t prt an NCK series startup file frm 840D pwerline withut prcessing t 840D sl. Prir t verwriting a licensed CF card, a backup f the license key is abslutely necessary The key is available in file keys.txt and is stred under the path card/keys/sinumerik The backup f the key can be carried ut, fr example, with WinSCP, by the PG / PC. Each license is assigned t a specific CmpactFlash card (card ID) and is nly valid n the assigned card. Mini handheld unit An additinal hardware is nw required t perate a mini handheld with handwheel. As previusly, the inputs are cnnected directly t the PLC I/Os r can alternatively be integrated int the input image f the MCP IE (X51 ) using a relevant cnnectin kit. Fr transmitting the handwheel signals, a machine cntrl panel (Ethernet r Prfibus) r a handwheel Prfibus cnnectin mdule is nw required as fr the type MPI handheld unit. Data backups shuld be read in in the rder NC, PL, drive. It will therefre make sense t create the NC, PLC and drive archives separately. Cntur handwheel and speed verride using a handwheel are nly release with Prfibus MCP. Siemens AG 2008 I DT R&D 51 Page 4 f 33

5 ShpTurn 1.5 SP2 The RESET buttn n the NCU can be used t restart the NCU mdule. It is nt ensured that this will als ensure a restart f the whle system in all cnfiguratins. This als applies fr the PI service f PLC with FB4. The catalg /siemens/system/etc. cntains a template fr the current standard basesys.ini. With intercnnected systems, we recmmend t assign names t the individual statins in the basesys.ini (e.g. hst name=ncu-2). If yu wish t intercnnect systems, the entry SyncMdeDHCPD_SysNet=ON_MASTER in the basesys.ini must be declared a cmment befre netwrking the DHCP master. Pwer-up sequence when starting up the system fr the first time after being intercnnected: DHCP master (s far DHCP server), then all ther statins. By default, Prt 102 n X130 is blcked. If yu wish t access the cntrller via X130 using STEP 7 r HMI, yu have t activate Prt 102. This can be achieved using the fllwing entry in the file /user/system/etc/basesys.ini: [LinuxBase] FirewallOpenPrts=TCP/102 If required, yu can als activate the Prt 5900 fr the VNC Viewer. The HT2 Ethernet handwheel is cnfigured at the fifth handwheel interface. Example fr three Ethernet handwheels. The third handwheel is lcated in HT2: MD11350[0]= [0]= [0]=1 MD11350[1]= [1]= [1]=2 MD11350[2]= [2]= [2]=5 HT2: The PLC applicatin example fr the HHU included with the Pwerline tlbx cannt be transferred t the HT2 withut several changes. The NCVAR variable descriptins must be adapted accrdingly. A revised example is prvided thrugh e_supprt r Tlbx. FC13 nw supprts the visualizatin f fur lines. As a result, the meaning f the ROW parameter has changed as fllws: 0 = N display utput 1 = 1st line 2 = 2nd line 3 = Line 1 and line 2 alternately 4 = 3rd line 5 = Line 1 and line 3 alternately 8 = 4th line F = Autmatic change f all lines The display cntents must be stred in the field ChrArray type string[64]. The upper fur keys are transferred t the PLC input image (the LEDs under these keys cannt yet be addressed). Sample parameter setting fr the HT2 at FB1 (OB100): BHG :=5 BHGIn :=DB100.BhgIn_170 BHGOut :=DB100.BhgOut_150 BHGStatSend :=DB100.DBD80 BHGStatRec :=DB100.DBD84 BHGInLen := BHGOutLen := BHGTimeut := BHGCycl := BHGRecGDN :=2 // crrespnds t the setting f the rtary switches * f the terminal bx resp. MPP. BHGRecGBZN :=2 // crrespnds t the setting f the rtary switches * f the terminal bx resp. MPP. BHGRecObjN :=1 BHGSendGDN :=2 BHGSendGBZN :=1 BHGSendObjN :=1 BHGMPI BHGStp BHGNtSend Siemens AG 2008 I DT R&D 51 Page 5 f 33

6 ShpTurn 1.5 SP2 * The rtary switches S1 and S2 at the terminal bx resp. MPP determine the DIP number used t register the nde in the system (here, S1=0, S2=2). Address 0 is nt permissible, as, with this setting, the DHCP Server cannt assign any addresses. HT2: The update rate f the display and the transfer f the handwheel signals (this imprves the velcity cntrl f the handwheel) can be imprved as fllws: Cpy the mcp_client file in the directry card\siemens\sinumerik\mcp_client\mcp_client.ini int the card\users\sinumerik\mcp_client directry and in the HT2 sectin, change the entry cyclemcpsend = 50. The cntrl must then be pwered dwn/pwered up. Alarm 46xx: The machine data fr the Ethernet handwheel must be checked. Example fr the first handwheel: MD11350[0]=7, 11351[0]=1, 11352[0]=1 Cmbinatins f NCUs with Sinamics Sxxx CUs have nt been released. Exceptins are nly permissible after prir cnsultatin. Spindle traversing with limited trque (Fcn) r spindle traversing t fixed stp: The perfrmance display at the HMI is calculated as 100% f the limited trque and utput. With NCK V r later and ADI4 bard V , the ADI4 bard can be perated n 840D sl with internal PLC 317. As befre, Dbsi 1 is nt released fr SINUMERIK with integrated drive cntrl. NCU Bis V1.4 (r later) is required t perate 1GB CmpactFlashCards in a NCU730. Upgrades are nly required infrequently s that the BIOS is nly available thrugh e_supprt. Just as befre, in cnjunctin with 840 D sl, the Starter is nly released fr diagnstic purpses. 4. Infrmatin abut the NCK: If the number f part prgrams set via machine data nearly crrespnds t the number f actually existing part prgrams, the value in the machine data must be increased (due t additinal cycles). The interplatry traversing f psitining axes is canceled with alarm Axis has nt IPO functinality. SPI and PW have (already always) been keywrds and cannt be used as axis identifiers. The G643 functin (blck-internal smthing) has been released fr applicatins in the tl change area (e.g. ptimizatins fr appraching the tl change psitin). The functin has nt been released fr applicatins in the machining prcess. The G644 functin (blck-internal smthing) has been released fr applicatins in the tl change area (e.g. ptimizatins fr appraching the tl change psitin). The functin has nt been released fr applicatins in the machining prcess. Sftware variant fr a max. f six axes: The default setting fr the number f axes is 3. The "Extended measurement" functin with distributed measuring input n the SINAMICS mdules is nt available (MEAC, MEASA, MEAWA). Gaps in the channel sequence are nt permitted in systems with a maximum f tw channels. Access t drive data via $nn_nn system variables is nt enabled. The nly available system variables are thse transferred in telegram 116. Extended stp and retract (ESR) has nt been enabled. ASUBs can nw be started alng the line f the 840Di functinality via the Prfibus PLC I/Os. Machine data settings must be selected by the same methd used n the 840Di system. There are n high-speed NCK I/Os mapped in DB10 f the PLC. Hwever, the ASUB start ptins used in earlier versins (i.e. frm DB10 r FC9 via PLC prgram) are still available. High-speed ET200 Simatic mdules can be used as a replacement fr the DMP mdules used n Pwerline. Fr this, yu can perate ne f the tw Prfibus lines in synchrnism with the clck with PLC317 in cmbinatin with NCK V r later (mre details are prvided in a separate descriptin). With a 31-axis sftware n an NCU 710.1, yu can use six ut f 31 axes and fur ut f ten channels. Machine data $MN_MAXNUM_PLC_CTRL_AXES is n lnger included in the data recrd. It has been replaced by MD MD $mn_psctrl_cycle_delay must be zer. Check the available data backup. Machine data $ma_rated_utval[ ] must have value zer. IMD (integrated mnitring & diagnstic) : Siemens AG 2008 I DT R&D 51 Page 6 f 33

7 ShpTurn 1.5 SP2 Feedback in GUD variable _PM_MISSING_TOOL_REFRESH after writing the variables t "1" is updated nly after image change. Safety: There is a new ptin handling referring t synchrnized actins r synchrnized actin elements. Up t versin 1.3 (NCK 62), synchrnized actin level 2 was set autmatically at the same time with ptin SI. Thus, channel MD 28250, NUM_SYNC_ELEMENTS culd be set t a value > 159. This has been changed with NCK versin 67. Synchrnized actin level 2 is n lnger included in Safety. Instead there is a new machine data, in which the synchrnized actin elements fr SAFE.SPF are defined, i.e. MD 28251, NUM_SAFE_SYNC_ELEMENTS. This machine data can be written with max. value 500 fr ptin SLP_I_O=1, and with a max. value f 5000 fr ptin SPL_I_O=2. Hwever, the number f synchrnized actin elements required shuld be determined in rder t prevent the perfrmance frm being laded unnecessarily. With system variable $AC_SAFE_SYNAC_MEM, the relevant number f free SI synchrnized actin elements can be read. If this variable is called prir t starting and after running SAFE.SPF, the difference is the number f elements ccupied by SAFE.SPF. This difference adding a certain reserve shuld be entered in MD Index 1-5 must be indicated when writing MD via synchrnized actins. Safety: Changed check sums f Safety integrated int the drive. The check sum fr these functins must be cnfirmed again due t new drive-integrated safety functins. T this end, enter 95 (safety start-up) in parameter p10. Subsequently, cpy the parameters f the current check sum t the parameters f the target check sum. p9798 t p9799 p9898 t p9899 Subsequently, p10 must be set t zer again. This will autmatically save the values (p971=1 is set). Wait fr the prcess f saving t be cmpleted. The prcesses mentined abve can als be triggered in HMI Advanced under IBN/NC/Safety Integrated using the sftkeys "Activate start-up mde" and "Deactivate start-up mde". With Sftware Versin 1.5 HF2 / 2.4 SP1 r later, the HT2 can be used as handheld unit. The auxiliary functin M6 is n lnger utput as standard after blck search. Remedy: Change the auxiliary functin grup in MD $mc_auxfu_predef_grup[5] int an unassigned grup. If the value f MD18210 deviates frm the default, MD18210 must be increased by min. 21 MB DRAM t upgrade the system frm SW1.4 / 2.4 t SW1.5 HF4 / 2.5 HF 1. Tl Manager: There is a new handling ptin. If several real magazines are used, these must be enabled using the ptin. One real magazine is included in the basic scpe. Fr cmpatibility reasns, the previus ptin bit $ON_TECHNO_FUNCTION_MASK Bit4=1 must still remain set. This is, hwever, nt included in the license handling. With SMI encder, the functin parking axis cannt be activated withut vltage Off/On. The functin fixed-pint apprach G75 is nt permissible with active radius crrectin G41 / G42 (Alarm Index 9). With fixed-pint apprach with G75, the fixed pint is nw apprached with nn-linear interplatin (RTLIOF). As a cnsequence, the axes are traversed with the jerk set fr psitining axes ($MA_JOG_AND_POS_MAX_JERK). The machine data 11295[0..9] is nw memry-cnfiguring. An alarm is nt utput in case f change. In existing archives, all values deviating frm the standard must be remved befre perfrming the upgrade. If yu wish t use the service interface X127 with PG/PC n a NCU7x0.2 with SW 2.6, yu have t ensure that the PG/PC netwrk interface is perated in "DHCP Client" mde, that means "Autmatically btain IP address ". After setting the PG/PC netwrk interface f a fixed IP ( xx), a ping is sent t X127, but yu cannt g nline neither with STEP 7 nr using a SINUMERIK Operate. The firewall is activated by default. The maximum CU r NX drive system lad may nt exceed 80% (lad displayed in parameter 9976[xx]). In the Reset state, the NCU lad exerted by psitin cntrller and interplatr may nt exceed 50%. The current lad can be checked under Diagnsis / System resurces. Siemens AG 2008 I DT R&D 51 Page 7 f 33

8 ShpTurn 1.5 SP2 Enhanced functins and further develpments: RQ ID AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP Infrmatin abut the PLC: Tlbx, V r higher, and Step 7, versin 5.4 SP2 r higher, are required. The current cycle time is n lnger available in DB5, but in DB8 instead. The cycle time can als be called via the start infrmatin f OB1. The PLC mdule IM153-2 MLFB 6ES AA02-0XB0 cannt be used. Remedy: 6ES AA03-0XB0 The PLC series startup file must be generated when the PLC is stpped. It cannt therwise be guaranteed that the PLC will switch t cyclic peratin when the data backup has been laded. Sinamics parameters are required fr star / delta switchver with FC17. Prerequisites: The relevant DDS/MDS must be set up in the drive. P827[0] P827[1] P827[n] must be set t different values. The cntactr is switched ver by the applicatin => P833, Bit0=1 The pulses are disabled by the drive => P833, Bit1=0 Initial PLC psitin: Star mde, therefre set bit 21.5 in the axis DB t 1 during pwer-up. The X127 service interface n the NCU is t be used exclusively fr start-up and service. The machine cntrl panel (MCP) is perated n Prfibus r Ethernet. N mixed peratin! Prfibus 1 must be cnfigured s that the CU, supply and drive sftkeys are displayed at the HMI. The blcks FC1007 AG_LOCK, FC1008 AG_UNLOCK, FC1010 AG_CNTRL have nt been released. The PLC FORCEN [FORCING] functin in cnjunctin with 840D sl has nly been released with sme restrictins. It is pssible with the PLC317 frm the PLC perating system >= V (2.4 SP1 HF11) / PLC319 and higher, PLC perating system >= V (2.4 SP1 HF11) and higher. With 840D sl, it is nt permissible t cnnect the VDI interface signal DB10.DBX Infrmatin abut the SINAMICS drive: The Starter may nt be used in cmbinatin with Sinumerik V1.5 / V2.5. N parallel use f measuring functins fr i and n measurements via starter and HMI Advanced. Starter measurements require a Pwer OFF => ON and immediate measurement with the starter. Starter measurements must nt be perfrmed after HMI Advanced measurements. If a SINAMICS cmpnent is replaced and the sftware upgraded, the firmware release must be checked and, where necessary, the riginal firmware release restred. (Key wrd: macr ) Firmware releases can be checked in the fllwing parameters: Cntrl unit R18 Firmware release f CU Supply R128 Firmware release f infeed Siemens AG 2008 I DT R&D 51 Page 8 f 33

9 ShpTurn 1.5 SP2 Drive MD R128 Firmware release f pwer unit R148 Firmware release f sensr mdule V1.4 / V2.4: Fr the time being, the starter is still required fr determining the mtr cdes. Mains vltages: Fr smth peratin in the target cuntry the fllwing parameters must be set in the specified rder: P010 = 1 P210 = rated mains vltage in the target cuntry P211 = rated mains frequency in the target cuntry P340 = 1 P3410 = 4 P3900 = 3 Save RAM t ROM Pwer OFF the system; pwer it ON again n the target netwrk nly. With the next ON cmmand at ALM a netwrk identificatin is run and the determined values are saved prtected against pwer failure. The APC functin increases the NCU lad. Prir t using this functin a perfrmance estimate must be carried ut. p1240, p1244, p1248, p1250: If Vdc cntrl and DDS switchver have been activated in V2.4, check if crrect values have been entered in the cntents f indexes >0 f p1240 after upgrading the system. DMC20/HUB has nt been released. With 840D sl and SW 1.5 SP1, 62.5 µs drive cycles have been released. The fllwing cnditins apply accrdingly: - with this setting, tw axes can be perated n ne CU r NX. - nly the same clck cycles can be set n a duble-axis mdule. Temperature prewarning messages (DB[axis].DBX94.0, DBX94.1) spradically ccur. Remedy: Only evaluate the signal in the PLC if this is pending in the VDI interface fr mre than 1.5 s. Fr SINUMERIK sftware releases 1.3 and 1.4/2.4, different firmware versins f the cmpnents (NCU, NX, Mtr Mdules, DRIVE-CLiQ mtrs) invlved in the safety functins can be cmbined (mixed) withut having t adapt the firmware versins. The fllwing applies frm SINUMERIK sftware release 1.5/2.5 and higher: The firmware versins f the Mtr Mdules, Sensr Mdules and DRIVE-CLiQ mtrs (include integrated Sensr Mdules) invlved in the safety functins must be adapted t the SINAMICS firmware versin f the NCU. This ccurs autmatically when bting, if parameter p9826 (firmware, autmatic) is set t 1 (standard setting). When using Safety Integrated, parameter p9826 (firmware, autmatic) must be set t 1 and must nt be re-parameterized. Fr the acceptance test f Safety Integrated, the safety firmware versins f all f the Mtr Mdules, Sensr Mdules and DRIVE-CLiQ mtrs - invlved in the safety functins - must be read-ut, lgged and checked against the fllwing list: Each line in the tables represents a pssible cmbinatin f safety firmware versins. When bting, chassis units must be perated in the pen-lp cntrl mde (refer t MD35020). Machine data change as a result f a changed Drive ES SlaveOM The Drive ES SlaveOM is respnsible fr allcating addresses f drive units cnnected t Prfibus f the PLC. The addresses are allcated in the PLC HW Cnfig. The addresses allcated here must be entered int the NC machine data MD13050[nn] crrespnding t the required axis cnfiguratin. When a Starter V4.1.n (r later) is installed (later, including the the installatin f tlbx V2.6), the new Drive ES SlaveOM is linked in. Cntrary t the previus situatin, nw, an address space fr 6 axes is reserved fr each CU r NX. This is realized when creating a PLC hardware cnfiguratin fr the first time. As a result, addresses may be shifted r gaps ccur. This mdified address allcatin must then be cmmunicated t the NC in machine data 13050[nn], as therwise the allcatins will n lnger be crrect. This is especially true if existing NC data back-ups (archives) are being used as therwise these will n lnger match the PLC hardware cnfiguratin. Siemens AG 2008 I DT R&D 51 Page 9 f 33

10 ShpTurn 1.5 SP2 Further, in HW Cnfig, the address f telegram 390 (PZD-2/2) f the first NX changes frm 6516 t When using additinal NX mdules, the address is incremented with an ffset f 10. Machine data MD13120[1+n] must be crrespndingly adapted. If existing PLC prjects are imprted int an S7 envirnment with new Drive ES SlaveOM, then the ld (previus) address cnfiguratins are kept. Hwever, the drive bjects that have been newly inserted int this prject receive the new address allcatin. A Standard (new) address allcatin is achieved using Rerganize addresses. If, fr NX bjects, the Standard telegram 1 (PZD-2/2) is entered frm an existing cnfiguratin, then this must be replaced by telegram 390 in rder t achieve a standard, new address allcatin. Example: One NCU with a Sinamics Integrated and tw NX10 each with 3 axes are cnfigured. Address allcatin with the Drive ES SlaveOM versin ld : On NX10_1, the 3 rd axis has the address 4420 On NX10_2, the 1 st axis has the address 4460 Address allcatin with the Drive ES SlaveOM new On NX10_1, the 3 rd axis has the address 4420 On NX10_2, the 1 st axis has the address 4580 Versin f Drive ES SlaveOM ld Siemens AG 2008 I DT R&D 51 Page 10 f 33

11 ShpTurn 1.5 SP2 PLC HW cnfiguratin Siemens AG 2008 I DT R&D 51 Page 11 f 33

12 ShpTurn 1.5 SP2 NX10_1 Siemens AG 2008 I DT R&D 51 Page 12 f 33

13 ShpTurn 1.5 SP2 NX10_2 Siemens AG 2008 I DT R&D 51 Page 13 f 33

14 ShpTurn 1.5 SP2 Versin f Drive ES SlaveOM new Siemens AG 2008 I DT R&D 51 Page 14 f 33

15 ShpTurn 1.5 SP2 NX10_1 Siemens AG 2008 I DT R&D 51 Page 15 f 33

16 ShpTurn 1.5 SP2 NX10_2 Siemens AG 2008 I DT R&D 51 Page 16 f 33

17 ShpTurn 1.5 SP2 Machine data13050[nn] Siemens AG 2008 I DT R&D 51 Page 17 f 33

18 ShpTurn 1.5 SP2 Re-rganizing addresses 7. Infrmatin abut HMI Embedded: The HMI Embedded sftware V07.50.xx is started autmatically as a cmpnent f the NCU sftware 1.5 in the pwer-up f the NCU7x0. HMI Embedded is als referred t as an "internal HMI". HMI Embedded can nly be perated via a cntrl panel with TCU cnnected via Ethernet t X120 n the NCU7x0. The cnfiguring data, such as PLC message and alarm texts and HMI ptin package ("Wizard"), must be stred n the CmpactFlash card in the NCU in the apprpriate directries under /card/user/sinumerik/hmi/... r /card/em/sinumerik/hmi/... (see dcumentatin IM2, BE1). The file system n the CmpactFlash card can be accessed in "nline" mde nly, i.e. when the NCU is running. The data can be transferred either by means f a USB stick r netwrk link via the HMI peratr interface (startup / HMI area) r by means f a netwrk link and the WinSCP tl. IMPORTANT: File names f cnfiguring files must nrmally be written in lwer case letters. Display MD 9990 SW_OPTIONS has n significance. All HMI ptins must be activated thrugh license management. The ptin "Additinal 256MB HMI user memry n the CmpactFlash card" is required t be able t stre part prgrams and archives n the CmpactFlash card ("lcal drive"). NOTICE: An NCK general reset deletes the ptin and renders the "lcal drive" inaccessible until the ptin is set again. Existing data stred n the card are nt affected. If yu are perating an NCU withut TCU (i.e. with HMI Advanced n PCU 50), it is advisable t deactivate HMI Embedded. Yu can d this by executing cmmand "sc disable hmi" in the service shell. Siemens AG 2008 I DT R&D 51 Page 18 f 33

19 ShpTurn 1.5 SP2 OP keybards can be switched between upper case and lwer case letters by simultaneusly pressing Shift+Ctrl. T be able t use the characters represented when pressing Shift (e.g. Shift A => [ ), capitalizatin must be active Limitatins in HMI Embedded: Muse peratin is nt supprted, peratin via tuch panel (als nt with HT8) is nt permissible. Cpying a file t CF card by verwriting an existing file with the same name will cause an "internal errr" message. The file with the same name must be deleted befre. Display MD 9210 USER_CLASS_WRITE_ZOA is nt active fr "active wrk ffset" in the Parameter area. Display MD 9900 MD_TEXT_SWITCH des nt have any effect. All cnfigured netwrk drives (access t server via Ethernet) must be permanently accessible during the runtime f HMI Embedded. Fr the cmmissining f the SINAMICS drives, an external HMI Advanced, sftware versin 7.5 r higher, r cmmissining tl 7.5 is required (the CD SINUCOM includes the cmmissining tl). Prcessing frm external surces / EXTCALL is nly permissible with single-channel machines. Ladable cmpile cycles cannt be backed up r read in using NC series startup archive. Ladable cmpile cycles are stred n the CF card f the NCU and retained in case f NC memry reset. They can be handled like HMI cnfiguring data. In a part prgram with EXTCALL calls, there must be at least ne ther NC blck between tw sequential EXTCALL calls with a prcessing duratin f at least ne secnd. When very big files are saved n CF card, the message "Please wait File being flashed" is displayed. This message must be acknwledged by pressing the Recall buttn. If yu want t switch ff the cntrl after having saved the file, yu will have t wait fr ne secnd fr each MB file size. After reading in a NC series startup archive, an explicit restart f the HMI is required, e.g. thrugh NCK reset r peratin with CTRL + Q, Enter. It is nt pssible t integrate a user bt screen. 7.2 Imprved functinality with respect t SW 1.5 SP1 HF2 AP AP The ShpMill interface may freeze in the editr The HMI might crash under certain circumstances in the G cde editr 8. Infrmatin abut the NCU Base sftware: The Linux perating system f the NCU7x0 is als referred t as the NCU Base sftware, similar t the PCU Base sftware fr the PCU 50. Yu will find the relevant dcumentatin in IM7 n the DVD-ROM. The NCU base sftware ensures the start amng ther things f the NC, PLC, and HMI sftware during pwer-up, as well as the bting f the TCU if it is present. The NCU Base sftware is user-riented, i.e. yu must lg in and enter a passwrd in rder t acquire specific access authrizatin. This current lgin and passwrd prtectin is nly relevant fr accessing a Linux service shell r the CmpactFlash card using WinSCP. Fr startup and servicing activities, the lgin ID is "manufact" and the passwrd "SUNRISE" (case-sensitive!). T pen the Linux service shell n the TCU, press keys "Area switchver" and "Recall" (F10 and F9) simultaneusly, then "Scan fr Servers", "2" r bt frm the USB service system. Fr access via the netwrk using WinSCP, enter the abvementined lgin and passwrd n the "Sessin" screen. This lgin prcedure als applies after the NCU7x0 has bted frm a USB stick with the NCU service system prvided that executable NCU sftware is installed n the CmpactFlash card. If this is nt the case (e.g. if the CmpactFlash card is empty), enter the lgin ID "admin" and passwrd "SUNRISE". Yu can display a list f the syntax f all available service cmmands in the service shell by running cmmand "sc help". Siemens AG 2008 I DT R&D 51 Page 19 f 33

20 ShpTurn 1.5 SP Netwrking: Please bserve the current dcumentatin "Operatr Cmpnents and Netwrking (IM5) Versin 04/2008"! Imprtant system and netwrk settings fr the NCU base sftware have been preset in the file basesys.ini in the directry /card/user/system/etc and may be mdified there. The riginal basesys.ini file is lcated at /card/siemens/system/etc, it is entitled "template-basesys.ini". Each NCU within the plant / system netwrk shuld be assigned a unique ("talking") cmputer name, tgether with the entry "Hst name=..." in basesys.ini. Permissible characters are uppercases / lwercases, numbers and minus signs. The NCU DHCP server shuld always be switched n. When upgrading the system frm SW 1.3 / 1.4 please ensure that n ld mcp_client.ini file remains in /card/user/sinumerik/mcp_client Cnfiguring 1 NCU with TCUs and MCPs In this cnfiguratin, n special settings must be made in the basesys.ini. The DHCP server and internal HMI-Embedded remain activated Cnfiguring 1 NCU with 1 PCU 50, MCPs and TCUs, if required In this cnfiguratin, make the fllwing settings in the basesys.ini f the NCU: Hst name =... SyncMdeDHCPD_SysNet = ON_MASTER In general, the internal HMI-Embedded must be deactivated because tw HMIs (HMI-Advanced and HMI-Embedded/JbShp) may nly be perated n ne NCU in particular cases. On PCU 50, we recmmend that yu use PCU base sftware V8.1 SP3 r later. In the System Netwrk Center, tab TCU Supprt, select the default cnfiguratin "N bt supprt". If the system is equipped with a TCU (HT8) that shall be switched t PCU 50 by default, the fllwing entries must be made in the file /card/user/cmmn/tcu/<tcu Name>/cmmn/tcu/cnfig.ini n the NCU MaxHstIndex = 1 [hst_1] Address = <IP address f the PCU> Cnfiguring several NCUs and, if necessary, 1 r several PCUs, TCUs, MCPs In this cnfiguratin, make the fllwing settings in the basesys.ini f the NCU: Unique hst name =... fr each NCU Unique InternalIP=... Unique InternalNetMask=... Exactly ne NCU with SyncMdeDHCPD_SysNet = ON_MASTER On PCU 50, yu have t use PCU base sftware V8.1 SP3 r later. In the System Netwrk Center, tab TCU Supprt, leave the default cnfiguratin "Cmplete TCUsupprt" unchanged. Under the tab DHCP Settings, we recmmend t set "Sync mde lw pririty". All peratr statins within the plant / system netwrk (TCUs, HT8, PCU 50) are managed n the NCU with "ON_MASTER", that means the cnfig.ini files as well as the.leases file cmprising all IP addresses assigned within the system which are relevant during the runtime are stred there. The cnfig.ini files are distributed t all ther NCUs / PCUs by the master NCU using the service cmmand "sc distribute tcudata". Via the Service cmmand "sc clear dhcp" and subsequent pwer ON / OFF f the cmplete system, the NCUs / PCUs are assigned preset IP addresses. New addresses are assigned t TCUs and MCPs and the.leases file is then distributed t all ther NCUs / PCUs. Imprtant: The System Netwrk Center, tab OPs allws t directly edit n each PCU 50 the cnfig.ini files f all peratr statins n the master NCU. The data are autmatically distributed t all NCUs / PCUs each time they are changed. 9. Infrmatin abut technlgy cycles: NCU sftware 1.5 SP1 includes the technlgy cycles (standard cycles) in an installable frm. Siemens AG 2008 I DT R&D 51 Page 20 f 33

21 ShpTurn 1.5 SP2 Installing the technlgy cycles: Step 1 - Reading in the archives Read in the necessary archive files: cyccust_gr.arc cyccust_uk.arc cycles.arc cycmill.arc cycturn.arc defines.arc ;*Archive fr user cycles German ;*Archive fr user cycles English ;*Archive with all standard cycles (milling and turning cycles) ;*Archive with all milling cycles ;*Archive with all milling cycles ;*Archive with definitin files In the "Services" area, select the "Prgram data" sftkey and navigate t "Cycle archive" using the cursr keys; t pen, use the Input key. In the "Cycle archive" area, navigate t "Standard cycles" using the cursr keys; t pen, use the Input key. Read in the necessary archive files by selecting the vertical sftkey "Read in archive". Nte: The archive files must be selected and read in separately. Once all the relevant archive files have been read in, yu must perfrm an NCK reset by selecting sftkey "NCK Reset" in the "Startup" area. Step 2 - Activating the definitin files In the "Prgram" area, select the ETC key ">" t g t the 3rd level. On this level, select the "Definitin files" sftkey, select the definitins separately and activate them using the "Activate" sftkey. Step 3 - Activating the "Swivel cycle" sftkey in the "Start-up" area In the "Prgram" area / "Standard cycles", edit the "cmmn.cm" file and delete the semicln in the beginning f the line ;SC616 = STARTUP.COM Then select the "NCK Reset" sftkey in the ">>Startup" area. Step 4 Activating the "Thread recutting" sftkey in the "Machine" area "Jg" In the "Prgram" area / "Standard cycles", edit the "cmmn.cm" file and delete the semicln in the beginning f the line ;SC108 = MA_JOG.COM Then select the "NCK Reset" sftkey in the ">>Startup" area. 10. Infrmatin abut measuring cycles: NCU sftware 1.5 SP1 includes the measuring cycles in an installable frm. Installing the measuring cycles: Step 1 - Machine data settings The machine data listed belw apply fr the use f Siemens standard and measuring cycles: (1) Machine data (memry-cnfiguring) fr Glbal User Data (GUDs): MD 18130: MM_NUM_GUD_NAMES_CHAN=130 (2) Machine data (memry-cnfiguring) fr number f cycles and number f transfer parameters MD 18180: MM_NUM_MAX_FUNC_PARAM=800 (3) Further machine data fr measuring cycles MD 11420: LEN_PROTOCOL_FILE=5 (maximum file size fr prtcl file, set in KB) MD 28082: MM_SYSTEM_FRAME_MASK Bit0 und Bit5 =1 (system frames fr scratching and cycles) Step 2 - Reading in the archives Read in the necessary archive files: Siemens AG 2008 I DT R&D 51 Page 21 f 33

22 ShpTurn 1.5 SP2 cyccust_gr.arc ;*Archive fr user cycles German cyccust_uk.arc ;*Archive fr user cycles English mcycles.arc ;*Archive with all measuring cycles (milling and turning) mcycmill.arc ;*Archive with all measuring cycles fr milling mcycturn.arc ;*Archive with all measuring cycles fr turning defines.arc ;*Archive with definitin files (GUD5.DEF, GUD6.DEF, GUD7_MC.DEF) jgmcyc.arc ;*Archive with all measuring cycles fr measuring in JOG In the "Services" area, select the "Prgram data" sftkey and navigate t "Cycle archive" using the cursr keys; t pen, use the Input key. In the "Cycle archive" area, navigate t "Measuring cycles" using the cursr keys; t pen, use the Input key. Read in the necessary archive files by selecting the 1st vertical sftkey "Read in archive". Nte: The archive files must be selected and read in separately. Once all the relevant archive files have been read in, yu must perfrm an NCK reset by selecting sftkey "NCK Reset" in the "Startup" area. Step 3 - Activating the definitin files In the "Prgram" area, select the ETC key ">" t g t the 3rd level. On this level, select the "Definitin files" sftkey, select the definitins GUD5.DEF, GUD6.DEF and GUD7.DEF separately and activate them using the "Activate" sftkey. Step 4 - Activating the access sftkeys "Measurement turning" and "Measurement milling" fr supprt In the "Prgram" area / "Standard cycles", edit the "cmmn.cm" file and delete the semicln in the beginning f the line ;SC326 = AEDITOR.COM ;* "Measurement turning" sftkey ;SC327 = AEDITOR.COM ;* "Measurement milling" sftkey Then select the "NCK Reset" sftkey in the ">>Startup" area. Step 5 - Activating the "Measuring cycles" sftkey in the "Start-up" area In the "Prgram" area / "Standard cycles", edit the "cmmn.cm" file and delete the semicln in the beginning f the line ;SC617 = STARTUP.COM Then select the "NCK Reset" sftkey in the ">>Startup" area. 11. Ntes n the cycles (ISO cycles) fr the "Online ISO Dialect Interpreter": NCU sftware 1.5 includes the ISO cycles V in an installable frm. Installing the ISO cycles: Installatin f the ISO cycles requires previus cmmissining f the standard cycles. Befre yu begin the startup prcess, yu shuld ensure that the existing status is saved t an archive; read ut a series startup archive if necessary. Dcumentatin: ISO dialects fr SINUMERIK 6FC5297-6AE10-0APx Prgramming Manual ISO Milling 6FC5298-6AC20-0BPx Prgramming Manual ISO Turning 6FC5298-6CA00-0BGx Step 1 - Machine data settings: Yu can activate the Online ISO Dialect Interpreter using the machine data $MN_EXTERN_LANGUAGE. The language types ISO dialect M (Milling) r T (Turning) can be selected via machine data $MN_EXTERN_CNC_SYSTEM. Step 2 - Reading in the archives ismill.arc ;*Archive with all ISO cycles fr milling isturn.arc ;*Archive with all ISO cycles fr turning defines.arc ;*Archive with definitin file (GUD7_ISO.DEF) Fr the prcedure fr reading in the archive files, please refer t: "Infrmatin abut the technlgy cycles" Siemens AG 2008 I DT R&D 51 Page 22 f 33

23 ShpTurn 1.5 SP2 An verview f the path structure n the CmpactFlash card in which the files fr the ISO cycles are stred can be fund belw. siemens/ sinumerik/ cycles/ archives isc/ hlps/ lngs/ prg/ defines.arc ismill.arc isturn.arc versins.xml prg.cfs prj/ startstp.sh versins.xml prj.cfs versins.xml ;Help files ;Language files ;Includes archives fr the ISO cycles ;Includes GUD7_ISO.DEF ;Includes the ISO cycles fr milling ;Includes the ISO cycles fr turning ;The XML file cntains the versin number f the ISO cycle archives ;Zipped prg/ flder ;Cnfiguratin ;Script file fr linking the subflders ;The XML file cntains the versin number ;Zipped prj/ flder ;Includes the versin numbers f the ISO cycles and Step 3 - Activating the definitin files Activate the GUD7.DEF definitin file. Fr the prcedure fr activating the definitins, please refer t: "Infrmatin abut the technlgy cycles" Siemens AG 2008 I DT R&D 51 Page 23 f 33

24 ShpTurn 1.5 SP2 List f G cdes with the crrespnding envelpe cycles and technlgy cycles: Milling: G Cde Envelpe Cycle Siemens Technlgy Cycles G05 CYCLE305 G08 CYCLE308 G10.6 CYCLE3106 G22 CYCLE322 G23 CYCLE323 G27 CYCLE328 G28 CYCLE328 G30 CYCLE330 CYCLE396 G71.1 / 72.2 CYCLE3721 G81 CYCLE381M CYCLE82 G82 CYCLE381M CYCLE82 G85 CYCLE381M CYCLE85 G86 CYCLE381M CYCLE88 G89 CYCLE381M CYCLE85 G83 CYCLE383M CYCLE83 G73 CYCLE383M CYCLE83 G84 CYCLE384M CYCLE3841 G74 CYCLE384M CYCLE3841 G76 CYCLE387M CYCLE86 G87 CYCLE387M CYCLE861 Turning: G Cdes A/B/C Envelpe Cycle Siemens Technlgy Cycles G05 CYCLE305 G10.6 CYCLE3106 G22 CYCLE322 G23 CYCLE323 G27 CYCLE328 G28 CYCLE328 G30 CYCLE330 CYCLE396 G50.2 / 51.2 CYCLE3512 G70 / 70 / 72 CYCLE370T G71 / 71 / 73 CYCLE371T CYCLE395 G90 / 77 / 20 CYCLE371T G72 / 72 / 74 CYCLE372T CYCLE395 G94 / 79 / 24 CYCLE372T G73 / 73 / 75 CYCLE373T G74 / 74 / 76 CYCLE374T CYCLE375T G75 / 75 / 77 CYCLE374T CYCLE375T G76 / 76 / 78 CYCLE376T CYCLE398 G92 / 78 / 21 CYCLE376T CYCLE398 G83 CYCLE383T CYCLE375T G87 CYCLE383T CYCLE375T G84 CYCLE384T CYCLE84 G88 CYCLE384T CYCLE84 G85 CYCLE385T CYCLE375T G89 CYCLE385T CYCLE375T Siemens AG 2008 I DT R&D 51 Page 24 f 33

25 ShpTurn 1.5 SP2 12. Infrmatin abut ShpTurn: General infrmatin: Upgrade in the metric unit system nly! The Wrk step prgramming ptin is required t create ShpTurn prgrams. The tl type "Limit stp" has been assigned number 730. Number 750 was used fr the "Limit stp" tl in ShpTurn befre. The change represents an adaptatin t HMI Advanced. Machine data fr ShpTurn: An verview is prvided under the Tls zer perating area => Extended sftkey bar => Machine data sftkey. N10134 $MN_MM_NUM_MMC_UNITS=6 ;minimum N10260 $MN_CONVERT_SCALING_SYSTEM=1 N10602 $MN_FRAME_GEOAX_CHANGE_MODE=1 N10610 $MN_MIRROR_REF_AX=0 N10700 $MN_PREPROCESSING_LEVEL='H25' : bit0=1, bit2=1, bit5=1 N10702 $MN_IGNORE_SINGLEBLOCK_MASK='H10' : bit4=1 N10714 $MN_M_NO_FCT_EOP=32 ;variable N10722 $MN_AXCHANGE_MASK='H4' : bit2=1 N10735 $MN_JOG_MODE_MASK='H1' : bit0=1 N11270 $MN_DEFAULT_VALUES_MEM_MASK='H1' : bit0=1 N11346 $MN_HANDWH_TRUE_DISTANCE=2 ;variable N11410 $MN_SUPPRESS_ALARM_MASK='H1007' : bit0=1, bit1=1, bit2=1, bit12=1 N11415 $MN_SUPPRESS_ALARM_MASK_2='H20' : bit5=1 N11450 $MN_SEARCH_RUN_MODE='H7' : bit0=1, bit1=1, bit2=1 N11470 $MN_REPOS_MODE_MASK='H8' : bit3=1 N11604 $MN_ASUP_START_PRIO_LEVEL=1 ;minimum N17530 $MN_TOOL_DATA_CHANGE_COUNTER='HF' : bit0=1, bit1=1, bit2=1, bit3=1 N18080 $MN_MM_TOOL_MANAGEMENT_MASK='HB' : bit0=1, bit1=1, bit3=1 N18118 $MN_MM_NUM_GUD_MODULES=7 ;minimum N18120 $MN_MM_NUM_GUD_NAMES_NCK=20 ;minimum N18130 $MN_MM_NUM_GUD_NAMES_CHAN=300 ;minimum N18150 $MN_MM_GUD_VALUES_MEM=120 ;minimum N18160 $MN_MM_NUM_USER_MACROS=30 ;minimum N18170 $MN_MM_NUM_MAX_FUNC_NAMES=200 ;minimum N18180 $MN_MM_NUM_MAX_FUNC_PARAM=3000 ;minimum N18280 $MN_MM_NUM_FILES_PER_DIR=400 ;minimum N18320 $MN_MM_NUM_FILES_IN_FILESYSTEM=400 ;minimum N20090 $MC_SPIND_DEF_MASTER_SPIND=??= Main spindle number frm MD35000 N20110 $MC_RESET_MODE_MASK='H04041' : bit0=1, bit6=1, bit14=1, bit16=0 N20112 $MC_START_MODE_MASK='H400' : bit10=1 N20128 $MC_COLLECT_TOOL_CHANGE=0 N20130 $MC_CUTTING_EDGE_RESET_VALUE=1 N20150 $MC_GCODE_RESET_VALUES[5]=2 N20150 $MC_GCODE_RESET_VALUES[15]=3 ;variable N20150 $MC_GCODE_RESET_VALUES[48]=3 ;variable N20152 $MC_GCODE_RESET_MODE[5]=0 N20152 $MC_GCODE_RESET_MODE[7]=1 N20152 $MC_GCODE_RESET_MODE[12]=0 N20152 $MC_GCODE_RESET_MODE[14]=1 N20152 $MC_GCODE_RESET_MODE[15]=0 N20202 $MC_WAB_MAXNUM_DUMMY_BLOCKS=10 ;minimum N20240 $MC_CUTCOM_MAXNUM_CHECK_BLOCKS=4 N20250 $MC_CUTCOM_MAXNUM_DUMMY_BLOCKS=5 N20310 $MC_TOOL_MANAGEMENT_MASK='H80400B' : bit0, 1, 3, 14, 16, 23=1 Siemens AG 2008 I DT R&D 51 Page 25 f 33

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2013-2-19 CNC Sftware with HMI-Embedded 1.4 SP3 HF1 SINUMERIK 840D sl, CNC system sftware 6 axes ) 6FC5840-1XG11-2YA0 with HMI Embedded, 6 languages, n CF Card; with license ) Exprt

More information

SINUMERIK 840D sl NCU Software with HMI Embedded 1.3 SP3

SINUMERIK 840D sl NCU Software with HMI Embedded 1.3 SP3 NCU Sftware with HMI Embedded 1.3 SP3 SINUMERIK 840D sl, NCU System Sftware fr six axes ) 6FC5840-1XG10-3YA0 with HMI Embedded, in 6 languages, n CF card; with license ) Exprt 6FC5840-1YG10-3YA0 SINUMERIK

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2010-10-20 CNC Sftware 2.4 SP3 with HMI sl SINUMERIK 840D sl, CNC system sftware fr 6 axes ) 6FC5850-1XG21-2YA0 with HMI sl, in six languages, n CF card; with license ) Exprt 6FC5850-1YG21-2YA0

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2009-10-22 ShpMill 1.5 SP2 SINUMERIK 840D sl, CNC SOFTWARE 6-3 ) 6FC5841-1XG11-0YA0 with ShpMill, in 6 languages (EN,DE,FR,IT,SP,V-CH), n CF card; with license ) Exprt 6FC5841-1YG11-0YA0

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5841-1XG10-6YA0 with ShpMill, in 6 languages, n CF card; with license ) Exprt 6FC5841-1YG10-6YA0 SINUMERIK 840D sl, NCU system sftware, fr 31 axes

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2010-07-13 CNC System Sftware 2.5 SP3 SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5850-1XG21-1YA0 with HMI sl, in 6 languages, n CF card; with license ) Exprt 6FC5850-1YG21-1YA0

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2010-08-10 CNC Sftware 2.6 SP1 HF2 SINUMERIK 840D sl, CNC system sftware 6 axes ) 6FC5850-1XG21-0YA0 with HMI-sl, 6 languages, n CF Card; with license ) Exprt 6FC5850-1YG21-0YA0 SINUMERIK

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2007-11-20 NCU Sftware with ShpTurn 1.4 SP1 HF1 SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5842-1XG10-4YA0 with ShpTurn HMI, in 6 languages, n CF card; with license ) Exprt

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2008-07-23 NCU System Sftware 2.5 HF2 SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5850-1XG20-3YA0 with HMI sl, in 6 languages, n CF card; with license ) Exprt 6FC5850-1YG20-3YA0

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2013-01-24 SINUMERIK 840D sl, CNC system sftware 6 axes ) 6FC5850-1XG21-5YA0 with HMI-sl, 6 languages, n CF Card; with license ) Exprt 6FC5850-1YG21-5YA0 SINUMERIK 840D sl, CNC system

More information

DIVAR IP 3000 Field Installation Guide

DIVAR IP 3000 Field Installation Guide CCTV IP Netwrk Vide Technical Brief DIVAR IP 3000 Field Installatin Guide 1 DIVAR IP 3000 Field Installatin Guide Overview The purpse f this guide is t prvide the step-by-step prcess f installing a DIVAR

More information

These tasks can now be performed by a special program called FTP clients.

These tasks can now be performed by a special program called FTP clients. FTP Cmmander FAQ: Intrductin FTP (File Transfer Prtcl) was first used in Unix systems a lng time ag t cpy and mve shared files. With the develpment f the Internet, FTP became widely used t uplad and dwnlad

More information

Manual for installation and usage of the module Secure-Connect

Manual for installation and usage of the module Secure-Connect Mdule Secure-Cnnect Manual fr installatin and usage f the mdule Secure-Cnnect Page 1 / 1 5 Table f Cntents 1)Cntents f the package...3 2)Features f the mdule...4 3)Installatin f the mdule...5 Step 1: Installatin

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2011-12-19 CNC Sftware 2.7 SP1 HF6 SINUMERIK 840DE SL CNC SOFTWARE 6-3 WITH SINUMERIK OPERATE 6 LANGUAGES (EN,DE,FR,IT,SP,CHS); EXPORT SOFTWARE 2.7 SP1 HF6 ON CF CARD WITH LICENSE 6FC5850-1YG23-1YA0

More information

1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader Hughes BGAN-X 9211 Upgrader User Guide (Mac) Rev 1.2 (6-Jul-17) This dcument explains hw t use the Hughes BGAN Upgrader prgram fr the 9211 User Terminal using a Mac Nte: Mac OS X Versin 10.4 r newer is

More information

HW4 Software Version 3.4.1

HW4 Software Version 3.4.1 Release ntes HW4 Sftware Versin 3.4.1 Change cntrl HW4 versin 3.4.1 includes all the functins and features f HW4 versin 3.4.0 with the fllwing mdificatins and additins: Enhancements: Nne New features Nne

More information

1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader Hughes BGAN-X 9202 Upgrader User Guide (Mac) Rev 1.0 (23-Feb-12) This dcument explains hw t use the Hughes BGAN Upgrader prgram fr the 9202 User Terminal using a Mac Nte: Mac OS X Versin 10.4 r newer is

More information

Firmware Upgrade Wizard v A Technical Guide

Firmware Upgrade Wizard v A Technical Guide Firmware Upgrade Wizard v4.1.1 A Technical Guide Nvember 2015 Intrductin The Firmware Upgrade Wizard prvides the fllwing features: It supprts upgrading the firmware n designated devices, see Supprted devices.

More information

USO RESTRITO. SNMP Agent. Functional Description and Specifications Version: 1.1 March 20, 2015

USO RESTRITO. SNMP Agent. Functional Description and Specifications Version: 1.1 March 20, 2015 Functinal Descriptin and Specificatins Versin: 1.1 March 20, 2015 SNMP Agent Simple Netwrk Management Prtcl Optin S fr IE and PM Mdules Supplement t Functinal Descriptin and Specificatins f RUB Ethernet

More information

HW4 Software version 3. Device Manager and Data Logging LOG-RC Series Data Loggers

HW4 Software version 3. Device Manager and Data Logging LOG-RC Series Data Loggers Page 1 f 18 HW4 Sftware versin 3 Device Manager and Data Lgging LOG-RC Series Data Lggers 2011; Page 2 f 18 Table f cntents 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 INITIAL SETUP... 4 3.1

More information

I. Introduction: About Firmware Files, Naming, Versions, and Formats

I. Introduction: About Firmware Files, Naming, Versions, and Formats I. Intrductin: Abut Firmware Files, Naming, Versins, and Frmats The UT-4500-A Series Upcnverters and DT-4500-A Series Dwncnverters stre their firmware in flash memry, which allws the system t uplad firmware

More information

IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016

IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016 IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016 1. What are tw functins f an perating system? (Chse tw.) cntrlling hardware access managing applicatins text prcessing flw chart editing prgram

More information

Please contact technical support if you have questions about the directory that your organization uses for user management.

Please contact technical support if you have questions about the directory that your organization uses for user management. Overview ACTIVE DATA CALENDAR LDAP/AD IMPLEMENTATION GUIDE Active Data Calendar allws fr the use f single authenticatin fr users lgging int the administrative area f the applicatin thrugh LDAP/AD. LDAP

More information

Release Notes. Dell SonicWALL Security firmware is supported on the following appliances: Dell SonicWALL Security 200

Release Notes. Dell SonicWALL  Security firmware is supported on the following appliances: Dell SonicWALL  Security 200 Release Ntes Email Security Dell SnicWALL Email Security 8.0.1 SnicOS Cntents System Cmpatibility... 1 Enhancements in Email Security 8.0.1... 2 Reslved Issues... 3 Upgrading t Email Security 8.0.1...

More information

UPGRADING TO DISCOVERY 2005

UPGRADING TO DISCOVERY 2005 Centennial Discvery 2005 Why Shuld I Upgrade? Discvery 2005 is the culminatin f ver 18 mnths wrth f research and develpment and represents a substantial leap frward in audit and decisin-supprt technlgy.

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2013-05-29 CNC Sftware 2.7 SP3 HF10 Installatin and perating ntes The CNC Sftware 2.7 SP3 HF10 can be perated n SINUMERIK NCUs 7x0.2 with MLBF...-_AA2 and NCUs 7x0.3. The CNC Sftware

More information

Upgrade Guide. Medtech Evolution General Practice. Version 1.9 Build (March 2018)

Upgrade Guide. Medtech Evolution General Practice. Version 1.9 Build (March 2018) Upgrade Guide Medtech Evlutin General Practice Versin 1.9 Build 1.9.0.312 (March 2018) These instructins cntain imprtant infrmatin fr all Medtech Evlutin users and IT Supprt persnnel. We suggest that these

More information

Dear Milestone Customer,

Dear Milestone Customer, Dear Milestne Custmer, With the purchase f Milestne Xprtect Transact yu have chsen a very flexible ptin t yur Milestne Xprtect Business slutin. Milestne Xprtect Transact enables yu t stre a serial data

More information

Adverse Action Letters

Adverse Action Letters Adverse Actin Letters Setup and Usage Instructins The FRS Adverse Actin Letter mdule was designed t prvide yu with a very elabrate and sphisticated slutin t help autmate and handle all f yur Adverse Actin

More information

I. Introduction: About Firmware Files, Naming, Versions, and Formats

I. Introduction: About Firmware Files, Naming, Versions, and Formats Updating Yur CTOG 250 Cmtech Traffic Optimizatin Gateway Firmware I. Intrductin: Abut Firmware Files, Naming, Versins, and Frmats The CTOG 250 Cmtech Traffic Optimizatin Gateway and its CDM 800 Gateway

More information

The screenshots/advice are based on upgrading Controller 10.1 RTM to 10.1 IF6 on Win2003

The screenshots/advice are based on upgrading Controller 10.1 RTM to 10.1 IF6 on Win2003 Overview The screenshts/advice are based n upgrading Cntrller 10.1 RTM t 10.1 IF6 n Win2003 Other Interim Fix (IF) upgrades are likely t be similar, but the authr cannt guarantee that the dcumentatin is

More information

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems Date: Octber 2018 User guide Integratin thrugh ONVIF driver. Prepared By: Devices & Integratins Team, Milestne Systems 2 Welcme t the User Guide fr Online Test Tl The aim f this dcument is t prvide guidance

More information

SINUMERIK 840D sl NCU Software and ShopMill HMI 1.3 SP3

SINUMERIK 840D sl NCU Software and ShopMill HMI 1.3 SP3 NCU Sftware and ShpMill HMI 1.3 SP3 SINUMERIK 840D sl, NCU System Sftware fr six axes ) 6FC5841-1XG10-2YA0 und ShpMill HMI, in six languages, n CF card; with license ) Exprt 6FC5841-1YG10-2YA0 SINUMERIK

More information

Campuses that access the SFS nvision Windows-based client need to allow outbound traffic to:

Campuses that access the SFS nvision Windows-based client need to allow outbound traffic to: Summary This dcument is a guide intended t guide yu thrugh the prcess f installing and cnfiguring PepleTls 8.55.27 (r current versin) via Windws Remte Applicatin (App). Remte App allws the end user t run

More information

1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader Hughes BGAN-X 9202 Upgrader User Guide (PC) Rev 1.0 (23-Feb-12) This dcument explains hw t use the Hughes BGAN-X Upgrader prgram fr the 9202 User Terminal using a PC. 1 Getting and Extracting the Upgrader

More information

Launching Xacta 360 Marketplace AMI Guide June 2017

Launching Xacta 360 Marketplace AMI Guide June 2017 Launching Xacta 360 Marketplace AMI Guide June 2017 Tels Crpratin 2017. All rights reserved. U.S. patents Ns. 6,901,346; 6,980,927; 6,983,221; 6,993,448; and 7,380,270. Xacta is a registered trademark

More information

Xilinx Answer Xilinx PCI Express DMA Drivers and Software Guide

Xilinx Answer Xilinx PCI Express DMA Drivers and Software Guide Xilinx Answer 65444 Xilinx PCI Express DMA Drivers and Sftware Guide Imprtant Nte: This dwnladable PDF f an Answer Recrd is prvided t enhance its usability and readability. It is imprtant t nte that Answer

More information

INSTALLING CCRQINVOICE

INSTALLING CCRQINVOICE INSTALLING CCRQINVOICE Thank yu fr selecting CCRQInvice. This dcument prvides a quick review f hw t install CCRQInvice. Detailed instructins can be fund in the prgram manual. While this may seem like a

More information

ABB i-bus KNX. Firmware information. KNX Security Panel, SM. Type: GM/A 8.1

ABB i-bus KNX. Firmware information. KNX Security Panel, SM. Type: GM/A 8.1 Firmware infrmatin Prduct: KNX Security Panel, SM Type: GM/A 8.1 Actual firmware versin 1.6: Applicatin: 000.005.000758 Runtime: 1.1.105.118358 Web interface: 1.3.6 KNX firmware: 1.0c Language package:

More information

Model WM100. Product Manual

Model WM100. Product Manual Mdel WM100 Prduct Manual Table f Cntents Sectin Page 1. Hardware... 3 2. Sftware... 4 3. Features... 5 4. Installatin... 6 5. App Devices... 9 6. App Rms... 12 7. App Scenes... 14 8. App Setup... 18 Cntents

More information

CaseWare Working Papers. Data Store user guide

CaseWare Working Papers. Data Store user guide CaseWare Wrking Papers Data Stre user guide Index 1. What is a Data Stre?... 3 1.1. When using a Data Stre, the fllwing features are available:... 3 1.1.1.1. Integratin with Windws Active Directry... 3

More information

HPE AppPulse Mobile. Software Version: 2.1. IT Operations Management Integration Guide

HPE AppPulse Mobile. Software Version: 2.1. IT Operations Management Integration Guide HPE AppPulse Mbile Sftware Versin: 2.1 IT Operatins Management Integratin Guide Dcument Release Date: Nvember 2015 Cntents Overview: The IT Operatins Management Integratin 3 System Requirements 3 Hw t

More information

Contents: Module. Objectives. Lesson 1: Lesson 2: appropriately. As benefit of good. with almost any planning. it places on the.

Contents: Module. Objectives. Lesson 1: Lesson 2: appropriately. As benefit of good. with almost any planning. it places on the. 1 f 22 26/09/2016 15:58 Mdule Cnsideratins Cntents: Lessn 1: Lessn 2: Mdule Befre yu start with almst any planning. apprpriately. As benefit f gd T appreciate architecture. it places n the understanding

More information

CCNA 1 Chapter v5.1 Answers 100%

CCNA 1 Chapter v5.1 Answers 100% CCNA 1 Chapter 6 2016 v5.1 Answers 100% 1. Which characteristic f the netwrk layer in the OSI mdel allws carrying packets fr multiple types f cmmunicatins amng many hsts? the de-encapsulatin f headers

More information

Avocent Power Management Distribution Unit (PM PDU) Release Notes Firmware Version April 18, 2011

Avocent Power Management Distribution Unit (PM PDU) Release Notes Firmware Version April 18, 2011 Avcent Pwer Management Distributin Unit (PM PDU) Release Ntes Firmware Versin 2.0.1.8 April 18, 2011 This dcument utlines: 1. Update Instructins 2. Appliance Firmware Versin Infrmatin 3. Features/Enhancements

More information

Integrating QuickBooks with TimePro

Integrating QuickBooks with TimePro Integrating QuickBks with TimePr With TimePr s QuickBks Integratin Mdule, yu can imprt and exprt data between TimePr and QuickBks. Imprting Data frm QuickBks The TimePr QuickBks Imprt Facility allws data

More information

Single File Upload Guide

Single File Upload Guide Single File Uplad Guide August 15, 2018 Versin 9.6.134.78 Single File Uplad Guide 1 Fr the mst recent versin f this dcument, visit ur dcumentatin website. Single File Uplad Guide 2 Table f Cntents 1 Single

More information

HPE LoadRunner Best Practices Series. LoadRunner Upgrade Best Practices

HPE LoadRunner Best Practices Series. LoadRunner Upgrade Best Practices HPE LadRunner Best Practices Series LadRunner 12.50 Upgrade Best Practices Dcument publicatin date: Nvember 2015 Cntents 1. Intrductin... 3 Overview... 3 Audience... 3 2. Preparatin... 3 Backup assets...

More information

UiPath Automation. Walkthrough. Walkthrough Calculate Client Security Hash

UiPath Automation. Walkthrough. Walkthrough Calculate Client Security Hash UiPath Autmatin Walkthrugh Walkthrugh Calculate Client Security Hash Walkthrugh Calculate Client Security Hash Start with the REFramewrk template. We start ff with a simple implementatin t demnstrate the

More information

Silent Messenger MegaTech Control Console

Silent Messenger MegaTech Control Console Silent Messenger MegaTech Cntrl Cnsle TRAFIX Operating System (Ver. 1.9.17) Menu Structure & Operating Instructins: SlarTech Splash Screen The SlarTech Splash Screen is presented at the cmpletin f system

More information

Xerox WorkCentre 7120/7125 Series User Instructions

Xerox WorkCentre 7120/7125 Series User Instructions Xerx WrkCentre 7120/7125 Series User Instructins Hw t Make a Cpy Using the Duplex Autmatic Dcument Feeder (DADF) NOTE: Use the DADF fr multiple r single pages. Use the Dcument Glass fr single cpies r paper

More information

Upgrade Guide. Medtech Evolution Specialist. Version 1.11 Build (October 2018)

Upgrade Guide. Medtech Evolution Specialist. Version 1.11 Build (October 2018) Upgrade Guide Medtech Evlutin Specialist Versin 1.11 Build 1.11.0.4 (Octber 2018) These instructins cntain imprtant infrmatin fr all Medtech Evlutin users and IT Supprt persnnel. We suggest that these

More information

Technical Paper. Installing and Configuring SAS Environment Manager in a SAS Grid Environment with a Shared Configuration Directory

Technical Paper. Installing and Configuring SAS Environment Manager in a SAS Grid Environment with a Shared Configuration Directory Technical Paper Installing and Cnfiguring Envirnment Manager in a Grid Envirnment with a Shared Cnfiguratin Directry Last Mdified: January 2018 Release Infrmatin Cntent Versin: January 2018. Trademarks

More information

SafeDispatch SDR Gateway for MOTOROLA TETRA

SafeDispatch SDR Gateway for MOTOROLA TETRA SafeDispatch SDR Gateway fr MOTOROLA TETRA SafeMbile ffers a wrld f wireless applicatins that help rganizatins better manage their mbile assets, fleet and persnnel. Fr mre infrmatin, see www.safembile.cm.

More information

Gemini Intercom Quick Start Guide

Gemini Intercom Quick Start Guide Gemini Intercm Quick Start Guide 2 Quick Start Guide Cntents Cntents... 1 Overview... 3 First Step unpack and inspect... 3 Netwrk plan and IP addresses... 4 Management PC... 5 Install Sftware... 6 Cnfigure

More information

Quick Installation Guide

Quick Installation Guide Oracle Strategic Operatinal Planning Release 3.5.1 Quick Installatin Guide Quick Installatin Guide This file cntains the fllwing sectins: Purpse... 1 System Requirements... 1 Server Cnfiguratin... 1 Client

More information

STIDistrict AL Rollover Procedures

STIDistrict AL Rollover Procedures 2009-2010 STIDistrict AL Rllver Prcedures General Infrmatin abut STIDistrict Rllver IMPORTANT NOTE! Rllver shuld be perfrmed between June 25 and July 25 2010. During this perid, the STIState applicatin

More information

Enabling Your Personal Web Page on the SacLink

Enabling Your Personal Web Page on the SacLink 53 Enabling Yur Persnal Web Page n the SacLink *Yu need t enable yur persnal web page nly ONCE. It will be available t yu until yu graduate frm CSUS. T enable yur Persnal Web Page, fllw the steps given

More information

Setting up the ncipher nshield HSM for use with Kerberized Certificate Authority

Setting up the ncipher nshield HSM for use with Kerberized Certificate Authority Setting up the ncipher nshield HSM fr use with Kerberized Certificate Authrity Intrductin This dcument cntains instructins fr setting up ncipher nshield hardware security mdules (HSM) fr use with the Kerberized

More information

NiceLabel LMS. Installation Guide for Single Server Deployment. Rev-1702 NiceLabel

NiceLabel LMS. Installation Guide for Single Server Deployment. Rev-1702 NiceLabel NiceLabel LMS Installatin Guide fr Single Server Deplyment Rev-1702 NiceLabel 2017. www.nicelabel.cm 1 Cntents 1 Cntents 2 2 Architecture 3 2.1 Server Cmpnents and Rles 3 2.2 Client Cmpnents 3 3 Prerequisites

More information

Proper Document Usage and Document Distribution. TIP! How to Use the Guide. Managing the News Page

Proper Document Usage and Document Distribution. TIP! How to Use the Guide. Managing the News Page Managing the News Page TABLE OF CONTENTS: The News Page Key Infrmatin Area fr Members... 2 Newsletter Articles... 3 Adding Newsletter as Individual Articles... 3 Adding a Newsletter Created Externally...

More information

OATS Registration and User Entitlement Guide

OATS Registration and User Entitlement Guide OATS Registratin and User Entitlement Guide The OATS Registratin and Entitlement Guide prvides the fllwing infrmatin: OATS Registratin The prcess and dcumentatin required fr a firm r Service Prvider t

More information

BMC Remedyforce Integration with Remote Support

BMC Remedyforce Integration with Remote Support BMC Remedyfrce Integratin with Remte Supprt 2003-2018 BeyndTrust, Inc. All Rights Reserved. BEYONDTRUST, its lg, and JUMP are trademarks f BeyndTrust, Inc. Other trademarks are the prperty f their respective

More information

New Product Release Package 8 XT[2] System and Software 19 Jan 2009

New Product Release Package 8 XT[2] System and Software 19 Jan 2009 New Prduct Release Package 8 XT[2] System and Sftware 19 Jan 2009 1.1 NEW OPERATIONAL FEATURES IN MULTICAM 8... 1 1.2 NEW HARDWARE FEATURES... 6 1.3 NEW SYSTEM FEATURES... 6 1.4 BUG FIXES UP TO 08.04.33...

More information

SINUMERIK 840D sl 03/03/2006 NCU Software 1.3 SP2

SINUMERIK 840D sl 03/03/2006 NCU Software 1.3 SP2 NCU Sftware 1.3 SP2 SINUMERIK 840D sl, NCU System Sftware fr six axes ) 6FC5842-1XG10-1YA0 and ShpTurn HMI, in six languages, n CF card; with license ) Exprt 6FC5842-1YG10-1YA0 SINUMERIK 840D sl, NCU System

More information

HW4 Software Version 3.7.0

HW4 Software Version 3.7.0 Release ntes HW4 Sftware Versin 3.7.0 Change cntrl HW4 versin 3.7.0 includes all the functins and features f HW4 versin 3.6.0 with the fllwing mdificatins and additins: Enhancements: CRP1: clean rm panel

More information

August 22, 2006 IPRO Tech Client Services Tip of the Day. Concordance and IPRO Camera Button / Backwards DB Link Setup

August 22, 2006 IPRO Tech Client Services Tip of the Day. Concordance and IPRO Camera Button / Backwards DB Link Setup Cncrdance and IPRO Camera Buttn / Backwards DB Link Setup When linking Cncrdance and IPRO, yu will need t update the DDEIVIEW.CPL file t establish the camera buttn. Setting up the camera buttn feature

More information

Integration Framework for SAP Business One

Integration Framework for SAP Business One Integratin Framewrk fr SAP Business One DIPrxy Cnfiguratin PUBLIC Glbal Rll-ut Octber 2018, B Zha TABLE OF CONTENTS 1 INTRODUCTION... 3 2 INSTALLATION... 3 3 CONFIGURATION... 5 3.1 Services in Service

More information

3 AXIS STAGE CONTROLLER

3 AXIS STAGE CONTROLLER CORTEX CONTROLLERS 50, St Stephen s Pl. Cambridge CB3 0JE Telephne +44(0)1223 368000 Fax +44(0)1223 462800 http://www.crtexcntrllers.cm sales@crtexcntrllers.cm 3 AXIS STAGE CONTROLLER Instructin Manual

More information

Procurement Contract Portal. User Guide

Procurement Contract Portal. User Guide Prcurement Cntract Prtal User Guide Cntents Intrductin...2 Access the Prtal...2 Hme Page...2 End User My Cntracts...2 Buttns, Icns, and the Actin Bar...3 Create a New Cntract Request...5 Requester Infrmatin...5

More information

Custodial Integrator. Release Notes. Version 3.11 (TLM)

Custodial Integrator. Release Notes. Version 3.11 (TLM) Custdial Integratr Release Ntes Versin 3.11 (TLM) 2018 Mrningstar. All Rights Reserved. Custdial Integratr Prduct Versin: V3.11.001 Dcument Versin: 020 Dcument Issue Date: December 14, 2018 Technical Supprt:

More information

TRAINING GUIDE. Overview of Lucity Spatial

TRAINING GUIDE. Overview of Lucity Spatial TRAINING GUIDE Overview f Lucity Spatial Overview f Lucity Spatial In this sessin, we ll cver the key cmpnents f Lucity Spatial. Table f Cntents Lucity Spatial... 2 Requirements... 2 Setup... 3 Assign

More information

Quick Start Guide. Basic Concepts. DemoPad Designer - Quick Start Guide

Quick Start Guide. Basic Concepts. DemoPad Designer - Quick Start Guide Quick Start Guide This guide will explain the prcess f installing & using the DemPad Designer sftware fr PC, which allws yu t create a custmised Graphical User Interface (GUI) fr an iphne / ipad & embed

More information

RISKMAN REFERENCE GUIDE TO USER MANAGEMENT (Non-Network Logins)

RISKMAN REFERENCE GUIDE TO USER MANAGEMENT (Non-Network Logins) Intrductin This reference guide is aimed at managers wh will be respnsible fr managing users within RiskMan where RiskMan is nt cnfigured t use netwrk lgins. This guide is used in cnjunctin with the respective

More information

Demand Forecasting. For. Microsoft Dynamics 365 for Operations. Technical Guide. Release 7.1. December 2017

Demand Forecasting. For. Microsoft Dynamics 365 for Operations. Technical Guide. Release 7.1. December 2017 Demand Frecasting Fr Micrsft Dynamics 365 fr Operatins Technical Guide Release 7.1 December 2017 2017 Farsight Slutins Limited All Rights Reserved. Prtins cpyright Business Frecast Systems, Inc. This dcument

More information

Refreshing Axiom TEST with a Current Copy of Production Axiom EPM June 20, 2014

Refreshing Axiom TEST with a Current Copy of Production Axiom EPM June 20, 2014 Refreshing Axim TEST with a Current Cpy f Prductin Axim EPM June 20, 2014 Refreshing Axim TEST If yu maintain an Axim TEST envirnment yu will want t refresh it with a current cpy f yur PROD database when

More information

Element Creator for Enterprise Architect

Element Creator for Enterprise Architect Element Creatr User Guide Element Creatr fr Enterprise Architect Element Creatr fr Enterprise Architect... 1 Disclaimer... 2 Dependencies... 2 Overview... 2 Limitatins... 3 Installatin... 4 Verifying the

More information

Re-Flashing Your CDM-760 Advanced High-Speed Trunking Modem

Re-Flashing Your CDM-760 Advanced High-Speed Trunking Modem Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem I. Intrductin: Firmware Files, Naming, Versins, and Frmats Make sure t perate the CDM-760 with its latest available firmware. Befre attempting

More information

Log shipping is a HA option. Log shipping ensures that log backups from Primary are

Log shipping is a HA option. Log shipping ensures that log backups from Primary are LOG SHIPPING Lg shipping is a HA ptin. Lg shipping ensures that lg backups frm Primary are cntinuusly applied n standby. Lg shipping fllws a warm standby methd because manual prcess is invlved t ensure

More information

Arius 3.0. Release Notes and Installation Instructions. Milliman, Inc Peachtree Road, NE Suite 1900 Atlanta, GA USA

Arius 3.0. Release Notes and Installation Instructions. Milliman, Inc Peachtree Road, NE Suite 1900 Atlanta, GA USA Release Ntes and Installatin Instructins Milliman, Inc. 3424 Peachtree Rad, NE Suite 1900 Atlanta, GA 30326 USA Tel +1 800 404 2276 Fax +1 404 237 6984 actuarialsftware.cm 1. Release ntes Release 3.0 adds

More information

UiPath Automation. Walkthrough. Walkthrough Calculate Client Security Hash

UiPath Automation. Walkthrough. Walkthrough Calculate Client Security Hash UiPath Autmatin Walkthrugh Walkthrugh Calculate Client Security Hash Walkthrugh Calculate Client Security Hash Start with the REFramewrk template. We start ff with a simple implementatin t demnstrate the

More information

Enterprise Installation

Enterprise Installation Enterprise Installatin Mnnit Crpratin Versin 3.6.0.0 Cntents Prerequisites... 3 Web Server... 3 SQL Server... 3 Installatin... 4 Activatin Key... 4 Dwnlad... 4 Cnfiguratin Wizard... 4 Activatin... 4 Create

More information

OO Shell for Authoring (OOSHA) User Guide

OO Shell for Authoring (OOSHA) User Guide Operatins Orchestratin Sftware Versin: 10.70 Windws and Linux Operating Systems OO Shell fr Authring (OOSHA) User Guide Dcument Release Date: Nvember 2016 Sftware Release Date: Nvember 2016 Legal Ntices

More information

Microsoft Excel Extensions for Enterprise Architect

Microsoft Excel Extensions for Enterprise Architect Excel Extensins User Guide Micrsft Excel Extensins fr Enterprise Architect Micrsft Excel Extensins fr Enterprise Architect... 1 Disclaimer... 2 Dependencies... 2 Overview... 2 Installatin... 4 Verifying

More information

Wave IP 4.5. CRMLink Desktop User Guide

Wave IP 4.5. CRMLink Desktop User Guide Wave IP 4.5 CRMLink Desktp User Guide 2015 by Vertical Cmmunicatins, Inc. All rights reserved. Vertical Cmmunicatins and the Vertical Cmmunicatins lg and cmbinatins theref and Vertical ViewPint, Wave Cntact

More information

Customer Information. Agilent 2100 Bioanalyzer System Startup Service G2949CA - Checklist

Customer Information. Agilent 2100 Bioanalyzer System Startup Service G2949CA - Checklist This checklist is used t prvide guidance and clarificatin n aspects f the auxillary Startup Service (G2949CA) including Security Pack Installatin and Familiarizatin f yur Agilent 2100 Bianalyzer System

More information

Quick Guide on implementing SQL Manage for SAP Business One

Quick Guide on implementing SQL Manage for SAP Business One Quick Guide n implementing SQL Manage fr SAP Business One The purpse f this dcument is t guide yu thrugh the quick prcess f implementing SQL Manage fr SAP B1 SQL Server databases. SQL Manage is a ttal

More information

istartsmart 3.5 Upgrade - Installation Instructions

istartsmart 3.5 Upgrade - Installation Instructions istartsmart 3.5 Upgrade - Installatin Instructins Minimum System Requirements: Hatch All-In-One istartsmart Cmputer Learning Center v1.0 r v1.1 Internet access - either hard-wired r wireless cnnectin is

More information

Technical Paper. Installing and Configuring SAS Environment Manager in a SAS Grid Environment

Technical Paper. Installing and Configuring SAS Environment Manager in a SAS Grid Environment Technical Paper Installing and Cnfiguring SAS Envirnment Manager in a SAS Grid Envirnment Last Mdified: Octber 2016 Release Infrmatin Cntent Versin: Octber 2016. Trademarks and Patents SAS Institute Inc.,

More information

RxAXIS Security Module 09/25/2013

RxAXIS Security Module 09/25/2013 RxAXIS Security Mdule 09/25/2013 Lessn Title Intrductin: Security Mdule In this tutrial we are ging t lk at the Security Maintenance Mdule f the RxAXIS system. When used, this system gives emplyees access

More information

TIBCO Statistica Options Configuration

TIBCO Statistica Options Configuration TIBCO Statistica Optins Cnfiguratin Sftware Release 13.3 June 2017 Tw-Secnd Advantage Imprtant Infrmatin SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED OR BUNDLED TIBCO

More information

Troubleshooting of network problems is find and solve with the help of hardware and software is called troubleshooting tools.

Troubleshooting of network problems is find and solve with the help of hardware and software is called troubleshooting tools. Q.1 What is Trubleshting Tls? List their types? Trubleshting f netwrk prblems is find and slve with the help f hardware and sftware is called trubleshting tls. Trubleshting Tls - Hardware Tls They are

More information

Getting started. Roles of the Wireless Palette and the Access Point Setup Utilities

Getting started. Roles of the Wireless Palette and the Access Point Setup Utilities Getting started The Wireless Palette is a sftware applicatin fr mnitring the cmmunicatin status between the Wireless LAN PC Card and the Wireless LAN Access Pint (hereinafter referred t as the Access Pint).

More information

File Share Navigator Online

File Share Navigator Online File Share Navigatr Online User Guide Service Pack 7 Issued September 2017 Table f Cntents What s New in this Guide... 4 Abut File Share Navigatr Online... 5 Cmpnents f File Share Navigatr Online... 5

More information

ClassFlow Administrator User Guide

ClassFlow Administrator User Guide ClassFlw Administratr User Guide ClassFlw User Engagement Team April 2017 www.classflw.cm 1 Cntents Overview... 3 User Management... 3 Manual Entry via the User Management Page... 4 Creating Individual

More information

ES93x INCA Add-On V1.4.0

ES93x INCA Add-On V1.4.0 ES93x INCA Add-On V1.4.0 Page 1 f 9 Cpyright The data in this dcument may nt be altered r amended withut special ntificatin frm ETAS GmbH. ETAS GmbH undertakes n further bligatin in relatin t this dcument.

More information

Installation and Getting Started

Installation and Getting Started Eurstat Data Transmissin Tls & Services EDAMIS Web Applicatin v3.1 Installatin and Getting Started TABLE OF CONTENTS: 1 Intrductin... 2 2 Installatin... 2 2.1 Prerequisites... 2 2.2 EWA installatin...

More information

Admin Report Kit for Exchange Server

Admin Report Kit for Exchange Server Admin Reprt Kit fr Exchange Server Reprting tl fr Micrsft Exchange Server Prduct Overview Admin Reprt Kit fr Exchange Server (ARKES) is an Exchange Server Management and Reprting slutin that addresses

More information

Technical Bulletin, Reflashing CPU

Technical Bulletin, Reflashing CPU Last Updated: 10-May-2011 TB-080002C Technical Bulletin, OMNI FLOW COMPUTERS, INC. 12620 West Airprt Bulevard, Suite 100 Sugar Land, Texas 77478 United States f America Phne-281.240.6161 Fax: 281.240.6162

More information

CCNA Security v2.0 Chapter 3 Exam Answers

CCNA Security v2.0 Chapter 3 Exam Answers CCNA Security v2.0 Chapter 3 Exam Answers 1. Because f implemented security cntrls, a user can nly access a server with FTP. Which AAA cmpnent accmplishes this? accunting accessibility auditing authrizatin

More information