EMC VSI for VMware vsphere: Path Management

Size: px
Start display at page:

Download "EMC VSI for VMware vsphere: Path Management"

Transcription

1 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide P/N REV 06

2 Copyright EMC Corporation. All rights reserved. Published in the USA. Published September EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC 2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date regulatory document for your product line, go to EMC Online Support at 2 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

3 CONTENTS Preface Chapter 1 Chapter 2 Chapter 3 Audience... 5 Required documentation... 6 Related documentation... 6 Conventions used in this document... 7 Where to get help... 9 EMC Virtual Storage Integrator for VMware vsphere Virtual Storage Integrator for VMware vsphere overview Path Management overview VMware Native Multipathing Plug-in EMC PowerPath/VE Software requirements VMware vsphere Client Operating systems VMware vcenter Server VMware ESXi EMC PowerPath Remote Tools (optional) VSI Feature Installation Installation overview Before you begin Installing VSI features Upgrading Enabling VSI Disabling VSI Uninstalling VSI Uninstalling a VSI feature Using VSI Feature Manager Using VSI for vsphere Client Getting started with VSI Using the VMware vsphere Client interface Path Management Storage class selection EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide 3

4 Contents Multipathing policy selection Set Multipathing Policy Summary page Chapter 4 VSI Configuration VSI logging Setting logging options EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

5 PREFACE As part of its effort to continuously improve and enhance the performance and capabilities of the EMC product line, EMC periodically releases revisions of its hardware and software. Therefore, some functions described in this document may not be supported by all revisions of the software and hardware currently in use. For the most up-to-date information on product features, refer to the current product release notes. If an EMC Virtual Storage Integrator (VSI) feature does not function properly or does not function as described in this guide, contact the EMC Customer Support Center for assistance. Audience This guide is part of the EMC Virtual Storage Integrator for vsphere vcenter Client documentation set and is intended for use by VMware administrators and storage administrators during installation, system setup, and routine operations. Storage administrators working with Virtual Storage Integrator must be proficient in the use of the following products: VMware products: VMware vsphere Client 5.x, with VMware vcenter Server 5.x, VMware 5.x, and VMware 5.x is installed EMC Symmetrix VMAX, EMC Celerra, EMC CLARiiON, EMC VNX, EMC VNXe storage arrays, EMC XtremIO, or EMC VPLEX systems, per your VSI supported product version, and the following applicable software: Solutions Enabler (SYMCLI/SYMAPI) EMC Symmetrix Remote Data Facility (SRDF) EMC PowerPath /VE, if installed Preface 5

6 Preface Required documentation The following documentation is part of the EMC Virtual Storage Integrator for vsphere Client documentation set, and is required for Virtual Storage Integrator depending on your installed feature: EMC VSI for VMware vsphere: Storage Viewer Version 5.6 Product Guide and Release Notes EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide and Release Notes EMC VSI for VMware vsphere: Unified Storage Management Version 5.6 Product Guide and Release Notes EMC VSI for VMware vsphere: AppSync Management Version 5.6 Product Guide and Release Notes EMC VSI for VMware vsphere: EMC RecoverPoint Management 5.6 Product Guide and Release Notes EMC VSI for VMware vsphere: Symmetrix SRA Utilities Version 5.6 Product Guide and Release Notes Related documentation The following EMC documentation contains information that may be helpful in a Virtual Storage Integrator environment and is available on EMC Online Support. EMC Solutions Enabler: EMC Solutions Enabler Symmetrix Array Controls CLI Product Guide EMC Solutions Enabler Symmetrix Array Management CLI Product Guide EMC Solutions Enabler Symmetrix SRDF Family CLI Product Guide EMC Solutions Enabler Symmetrix TimeFinder Family CLI Product Guide EMC Solutions Enabler Installation Guide EMC Symmetrix Array: Using EMC Symmetrix Storage in VMware vsphere Environments (TechBook) Using EMC SRDF Adapter for VMware vcenter Site Recovery Manager (TechBook) 6 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

7 Preface EMC ControlCenter : EMC ControlCenter Planning and Installation Guide Symmetrix SRDF Host Component Product Guide EMC PowerPath: EMC PowerPath Product Guide Conventions used in this document EMC uses the following conventions for special notices. Note: A note presents information that is important, but not hazard-related. A caution contains information essential to avoid data loss or damage to the system or equipment. The caution may apply to hardware or software. IMPORTANT An important notice contains information essential to operation of the software. The important notice applies only to software. Preface 7

8 Preface Typographical conventions EMC uses the following type style conventions in this document: Normal Bold: Italic: Courier: Courier bold: Courier italic: Used in running (nonprocedural) text for: Names of interface elements (such as names of windows, dialog boxes, buttons, fields, and menus) Names of resources, attributes, pools, Boolean expressions, buttons, DQL statements, keywords, clauses, environment variables, filenames, functions, utilities URLs, pathnames, filenames, directory names, computer names, links, groups, service keys, file systems, notifications Used in running (nonprocedural) text for names of commands, daemons, options, programs, processes, services, applications, utilities, kernels, notifications, system call, man pages Used in procedures for: Names of interface elements (such as names of windows, dialog boxes, buttons, fields, and menus) What user specifically selects, clicks, presses, or types Used in all text (including procedures) for: Full titles of publications referenced in text Emphasis (for example a new term) Variables Used for: System output, such as an error message or script URLs, complete paths, filenames, prompts, and command syntax. Used for specific user input (such as commands) Used in procedures for: Variables on command line User input variables < > Used to enclose parameter or variable values supplied by the user [ ] Used to enclose optional values Indicates alternate selections - the bar means or { } Indicates content that you must specify (that is, x or y or z)... Indicates nonessential information omitted from the example 8 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

9 Preface Where to get help EMC support, product, and licensing information can be obtained as follows. Product information For documentation, release notes, software updates, and information about EMC products, licensing, and service, go to: Technical support For technical support, go to the Service Center at To open a service request, you must have a valid support agreement. Please contact your EMC sales representative for details about obtaining a valid support agreement or to answer any questions about your account. Your suggestions will help us continue to improve the accuracy, organization, and overall quality of the user publications. Please send your opinion of this document to: techpub_comments@emc.com Preface 9

10 Preface 10 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

11 CHAPTER 1 Invisible Body Tag EMC Virtual Storage Integrator for VMware vsphere This chapter provides an overview of the EMC VSI for VMware vsphere plug-in. IMPORTANT EMC recommends reading this chapter in its entirety before installing and configuring the VSI Client plug-in. This chapter includes the following topics: Virtual Storage Integrator for VMware vsphere overview Path Management overview VMware Native Multipathing Plug-in EMC PowerPath/VE Software requirements EMC Virtual Storage Integrator for VMware vsphere 11

12 EMC Virtual Storage Integrator for VMware vsphere Virtual Storage Integrator for VMware vsphere overview VSI is an EMC-developed plug-in to the VMware vcenter management software. VSI enables the VMware administrator to provision, monitor, and manage VMware vsphere datastores on EMC storage arrays and more easily manage the virtualized environment. This plug-in supports all EMC arrays including VNX, VNXe, VMAX10K, VMAX 20K, VMAX 40K, CLARiiON, Celerra systems, XtremIO arrays, and the VPLEX storage system. VSI is available to customers at no charge. Features are managed by using the VSI Feature Manager. VSI provides a unified user experience, enabling each of the features to be updated independently and new features to be introduced rapidly in response to changing customer requirements. Features available for VSI include Storage Viewer, Path Management, Symmetrix Storage Replication Adapter (SRA) Utilities, Unified Storage Management, AppSync Management, and EMC RecoverPoint Management. The Storage Viewer feature extends the vsphere Client to facilitate the discovery and identification of EMC Symmetrix, CLARiiON, Celerra, VPLEX, XtremIO, VNX, and VNXe storage devices that are allocated to VMware ESXi hosts and virtual machines. Storage Viewer presents the underlying storage details to the virtual datacenter administrator by merging the data of several different storage mapping tools into a few seamless vsphere Client views. The Path Management feature for VMware Native Multipathing and EMC PowerPath/VE provides a mechanism for changing the multipath policy for groups of LUNs based on storage class and virtualization object. The Symmetrix SRA Utilities feature helps users to more efficiently manage vcenter Site Recovery Manager (SRM) configurations in Symmetrix Remote Data Facility (SRDF ) environments. It provides SRM diagnostic tools that help users to easily identify configuration errors. The SRA Utilities feature enables users to create and view consistency groups. The Unified Storage Management feature provides array-based storage management and provisioning for CLARiiON, Celerra, VMAX, VPLEX, XtemIO, VNX, and VNXe series storage arrays, and enables virtual machine decompression, compression, and cloning, and extending storage for arrays. The AppSync Management feature provides VMware vsphere datastore protection management based on the AppSync server with service plan configuration and datastore copy mount, unmount, restore, and expire functions. 12 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

13 EMC Virtual Storage Integrator for VMware vsphere The EMC RecoverPoint Management feature is designed to assist you in recovering data when you are using VMware vcenter Site Recovery Manager. With EMC RecoverPoint Management, you can select specific point-in-time backups to be used for your data protection and disaster recovery needs. Path Management overview The Path Management feature for EMC VSI for VMware vsphere includes support for both VMware Native Multipathing Plug-in (NMP) and PowerPath/VE. Currently, the Storage Viewer feature displays multipath properties for both NMP and PowerPath/VE. Those properties include the number of paths, the state of those paths, and the policy used to manage those paths. The Path Management feature allows you to change the multipath policy and is a first step in allowing the VSI user to manage multiple paths from within the VMware vsphere Client. The Path Management features allows a VSI user to change the multipath policy on a multitude of devices, based on both storage class and virtualization object. For example, all Symmetrix devices for a given ESXi host or all CLARiiON devices for a given VMware vsphere cluster can be managed. With the Path Management features, managing multipath policies can be performed for devices owned by both NMP and PowerPath/VE. This feature is a valuable asset to administrators who need to maintain consistent multipath policies across a large virtual datacenter containing a large number or wide variety of storage devices. This Product Guide describes the behavior and functionality available with the Path Management feature for EMC VSI for VMware vsphere Client. The document provides snapshots of the various views, the functionality that is available with each of these views, and sample use cases. VMware Native Multipathing Plug-in By default, VMware ESXi hosts come with NMP enabled to manage multipathed storage. Several Storage Array Type Plug-ins (SATPs) built into ESXi determine the default Path Selection Plug-in (PSP) that is used for a given storage device type. The PSP is analogous to a multipath policy, because it determines how and when multiple paths are used for a given storage device. Prior to vsphere 5.1, Symmetrix storage has a SATP of VMW_SATP_SYMM, which has a PSP of VMW_PSP_FIXED. Starting in vsphere 5.1, the default policy is NMP RR. When you connect a Symmetrix device to an ESXi host by using multiple paths, those paths will be managed with a fixed policy. EMC Virtual Storage Integrator for VMware vsphere 13

14 EMC Virtual Storage Integrator for VMware vsphere EMC PowerPath/VE Software requirements VMware vsphere Client CLARiiON storage that does not support Asymmetric Logical Unit Access (ALUA) has an SATP of VMW_SATP_CX, which uses a PSP of VMW_PSP_MRU. This means that when you connect a CLARiiON device to an ESXi host by using multiple paths, those paths will be managed with a Most Recently Used policy. It is possible to alter the default PSP used for a given SATP by using the esxcli. For example, many customers change the VMW_SATP_SYMM to use the VMW_PSP_RR to get a round robin multipathing policy. EMC PowerPath/VE is an example of a MultiPath Plugin (MPP) or Multipath Enhancement Module (MEM), based on the PSA of VMware vsphere 4.0. When PowerPath/VE is installed, it can replace the NMP SATP for certain storage devices. By default, according to the PowerPath/VE claim rules, PowerPath/VE owns all EMC storage devices after it is installed. NMP continues to exist on the ESXi host and it continues to exist on any storage devices that are not owned by PowerPath/VE. It is even possible to switch devices from being managed by PowerPath/VE back to being managed by NMP (although this defeats the point of installing PowerPath/VE). The advantage of having PowerPath/VE is that it is programmed for best practices and immediately improves path discovery, path selection (from a basic round robin to adaptive), and predictability. While NMP is managed from the ESXi console by using esxcli, PowerPath/VE is managed by a remote command line utility, rpowermt.exe. This utility is installed with the PowerPath/VE Remote Tools kit, which is a requirement for this feature to work with PowerPath/VE. This section describes the software requirements for VSI for VMware vsphere version 5.6. VSI for VMware vsphere version 5.6 requires VMware vsphere Client 5.0 or later. The VMware software must be installed prior to installation of VSI features. 14 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

15 EMC Virtual Storage Integrator for VMware vsphere Operating systems VSI for VMware vsphere is supported on the same operating systems that are supported by the VMware vsphere Client. Currently, this includes only Microsoft Windows operating systems. The VMware Infrastructure Compatibility Matrixes with the complete list of supported operating systems can be found at the VMware website: Note: For x64 operating systems, all installed software components will be x86 images that are running in compatibility mode. VMware vcenter Server The vsphere Client is used to connect to a vcenter Server that manages the entire virtual datacenter, including any number of ESXi hosts. VSI for VMware vsphere version 5.6 is supported with VMware vcenter Server 5.0 or later. Attempting to connect to a version of VMware vcenter Server earlier than this results in changes to the vsphere Client that VSI does not support. Note: EMC VSI for VMware vsphere does not support VMware vcenter Linked Mode. VMware ESXi VSI for VMware vsphere: Path Management version 5.6 is supported with VMware ESXi version 5.0 or later. Connection must be through the vcenter Server to access the Path Management wizard, since the Path Management feature uses the vcenter task functionality. The Path Management features are disabled when the VMware vsphere Client is connected directly to an ESXi host. EMC PowerPath Remote Tools (optional) For the Path Management feature to work with PowerPath/VE, the PowerPath/VE Remote Tools must be installed on the client where VSI is running. The Path Management feature requires PowerPath/VE Remote Tools version 5.8.b342 or later. If the software is not installed, or an older version is installed, then the Path Management feature will continue to function, but the user will not be able to operate EMC Virtual Storage Integrator for VMware vsphere 15

16 EMC Virtual Storage Integrator for VMware vsphere on devices owned by PowerPath. When PowerPath/VE is installed on an ESXi host, VSI presents important multipath details for a given device, such as the multipath policy employed, the number of active paths, the number of dead paths, and so on. Note: For VSI to obtain and present PowerPath/VE multipath details for the underlying storage, the PowerPath Remote Tools for Windows package must be installed. VSI currently supports PowerPath Remote Tools version 5.8.b342 or later. If this software is not installed, VSI features will still be installed successfully, but the PowerPath details will not be available. The Path Management feature is supported only when connecting to a vcenter Server. If the VMware vsphere Client is connected directly to an ESXi server, the Path Management feature is disabled. The vcenter user is required to have the Host.Cim.CimInteraction permission set, which is included in the vcenter administrator role by default. 16 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

17 CHAPTER 2 Invisible Body Tag VSI Feature Installation This chapter explains how to install, enable, disable, and uninstall VSI for VMware vsphere plug-in features. Topics include the following: Installation overview Installing VSI features Enabling VSI Disabling VSI Uninstalling VSI Using VSI Feature Manager VSI Feature Installation 17

18 VSI Feature Installation Installation overview Before you begin VSI for VMware vsphere VMware vsphere Client Installing VSI features This chapter describes how to install VSI 5.6 features, enable and disable the VSI plug-in, uninstall VSI, and disable and uninstall individual VSI features by using the Feature Manager. Before you begin to install a VSI feature, read the following installation requirements and considerations. VSI for VMware vsphere version 5.6 is a plug-in to VMware vcenter that provides a single management interface used for managing EMC storage within the vsphere environment. VSI features can be added and removed from VSI independently, providing flexibility for customizing VSI user environments. Features install separately and contain the complete VSI plug-in framework for using that feature. Features can be managed by using the VSI Feature Manager. Install the VMware vsphere Client version 5.0 or later onto the same host as VSI. VSI will not install if the VMware vsphere Client is not already installed. After you have installed the VMware vsphere Client, you can install VSI for VMware vsphere features: 1. Download the VSI for VMware vsphere feature Zip file from EMC Online Support ( 2. Unzip the file that you downloaded and run emc-vsi-pm vmware-vsphere- WINDOWS-x86.exe. The installation wizard copies all of the necessary files. Each feature is installed separately and contains all of the necessary components for that feature. No configuration or input is required during the installation other than accepting the prompts to move forward with the install. The installation directory cannot be changed because the vsphere Client requires the plug-in files to be placed in a specific location. 18 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

19 VSI Feature Installation Upgrading When VSI version 3.x or later is installed, you can upgrade the software to a newer version by using the install wizard. The upgrade to version 5.6 will not retain any of the configuration options, but the log files will be retained for Storage Viewer and the Solutions Enabler server. Note: For VSI PowerPath Management, you can upgrade from version 4.x or later. IMPORTANT After upgrading VSI, it is possible that certain features will be removed and must be reinstalled. Enabling VSI To enable the VSI plug-in, follow these steps: 1. Start the vsphere Client. 2. From the top menu, select Plugins > Manage Plugins. 3. Locate and then right-click the EMC Virtual Storage Integrator in the list of available plug-ins, and select Enabled. The status changes from Disabled to Enabled, and VSI loads automatically. This process does not require a restart of vsphere Client. 4. Select Close to exit the Plug-in Manager. VSI Feature Installation 19

20 VSI Feature Installation Disabling VSI Uninstalling VSI If you no longer want to use the VSI plug-in, but do not want to uninstall it, you can disable it as follows: 1. Start the vsphere Client. 2. From the top menu, select Plugins > Manage Plugins. 3. Locate and then right-click the EMC Virtual Storage Integrator in the list of available plug-ins, and select Disable. The status changes from Enabled to Disabled. This process does not require a restart of vsphere Client. 4. Select Close to exit the Plug-in Manager. VSI can be uninstalled by using the Windows Add or Remove Programs utility. This removes the VSI framework and the VSI feature. Before uninstalling VSI, exit VMware vsphere Client in all user sessions on the client host. To uninstall VSI by using the Add or Remove Programs utility, follow these steps: 1. Open the Add or Remove Programs utility in the Control Panel by selecting Start > Settings > Control Panel. 2. When the list of currently installed programs loads, select EMC Virtual Storage Integrator for VMware vsphere. Note: Using Add or Remove Programs to uninstall the VSI plug-in removes all installed VSI features at once. No individual selection is possible. Uninstalling a VSI feature 3. Select Change/Remove and follow the dialogs presented. The VSI feature can be repaired or removed by running the installer.exe that was downloaded from EMC Online Support. Selecting the Remove option removes only the VSI feature. The VSI framework remains installed and listed under Add or Remove Programs. 20 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

21 VSI Feature Installation Using VSI Feature Manager After enabling the VSI plug-in, click the EMC VSI icon located in the Solutions and Applications menu to open the VSI home view. Select Feature Manager from the Settings tree menu. Installed VSI features display in a list. Figure 1 on page 21 shows an example. The feature status automatically appears as enabled. To disable or uninstall a particular feature, right-click the feature and select Disable or Uninstall. Disabled features remain fully installed and can be enabled for later use. Uninstalled features are permanently removed once the vsphere Client is closed and must be reinstalled separately. To enable a disabled feature at a later time, use the Feature Manager right-click menu again and select Enable. Figure 1 VSI Feature Manager VSI Feature Installation 21

22 VSI Feature Installation 22 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

23 CHAPTER 3 Invisible Body Tag Using VSI for vsphere Client This chapter explains how to use the VSI for VMware vsphere plug-in feature software with the VMware vsphere Client interface. Topics include the following: Getting started with VSI Path Management Using VSI for vsphere Client 23

24 Using VSI for vsphere Client Getting started with VSI Use EMC VSI for VMware vsphere to connect to a vcenter Server. 1. Open the VMware vsphere Client. 2. From the Home menu, click the EMC VSI icon located in the Solutions and Applications menu to open the VSI plug-in. 3. Select Feature Manager from the Settings tree menu. All installed VSI features are displayed in a list. Figure 2 on page 24 shows an example with multiple features installed and enabled. Using VSI Feature Manager on page 21 provides information on using Feature Manager to disable or uninstall features. Figure 2 VSI plug-in features 24 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

25 Using VSI for vsphere Client Settings This pane provides access to the Feature Manager function, which can be used to manage the separate plug-in features. It also provides access to logging information for each installed feature. VSI logging on page 32 provides information for using the VSI logging function. Features With Storage Viewer installed, this pane lists all of the storage arrays and servers that VSI has knowledge of, and enables the discovery of new arrays and the deletion of previously discovered arrays. Using the VMware vsphere Client interface The VSI for vsphere Client provides context-sensitive storage information depending on the object that is selected from the navigation tree located in the left-hand pane. If you selected an ESXi host from the navigation tree, as shown in Figure 3, information for the host appears in the right-hand pane. Different information appears when you select a virtual machine from the navigation tree. Figure 3 Opening an ESXi host view Using VSI for vsphere Client 25

26 Using VSI for vsphere Client Path Management You access the EMC Path Management feature menu by right-clicking the ESXi host or cluster. Select Set Multipathing Policy to open the Path Management wizard, as shown in Figure 4. The Path Management wizard aids you in selecting multipathing policies for classes of storage devices. Figure 4 EMC Path Management feature menu The Set Multipathing Policy page is the first in the wizard. It presents two distinct areas of control, one for VMware NMP and the other for EMC PowerPath/VE. Figure 5 on page 27 provides an example. Note: If PowerPath/VE is not installed or is unlicensed, then that portion of the screen is disabled. 26 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

27 Using VSI for vsphere Client Figure 5 Set Multipathing Policy wizard 1. Select the parameters for NMP. 2. Select parameters for PowerPath/VE only if the following PowerPath/VE components are in place (otherwise you cannot specify these parameters): EMC PowerPath/VE must be installed and licensed on the ESXi hosts in question. If it is not, a warning message is posted and this portion of the page is disabled. EMC PowerPath Remote Tools for Windows must be installed on the client host (where VM vsphere Client is running). If it is not, a warning message is posted and this portion of the page is disabled. Using VSI for vsphere Client 27

28 Using VSI for vsphere Client Storage class selection To select a policy for the native multipathing-owned devices: 1. Select from the drop-down list the storage classes to be affected. 2. When you select a specific storage class, such as All Symmetrix Devices, another drop-down list is displayed so that you can select additional storage classes. If you select a general storage class, such as All EMC Devices, then only the one drop-down box is needed. For NMP, the following storage classes are available: All Devices All EMC Devices All Symmetrix Devices All CLARiiON Devices All VPLEX Devices All VNX Devices For PowerPath/VE, the following storage classes are available: All Devices All EMC Devices All Symmetrix Devices All CLARiiON Devices All VPLEX Devices All VNX Devices Multipathing policy selection Once a storage class is selected, the multipathing policy drop-down box is enabled for editing. You can opt not to change the multipathing policy by using the Do Not Change option, even if a storage class is selected. For NMP, the multipathing policy options change according to the ESXi Server, not according to storage class, except for Symmetrix devices. 28 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

29 Using VSI for vsphere Client With ESX/ESXi Server 5.x, the NMP multipathing policy options are: Do Not Change Fixed Most Recently Used (MRU) Round Robin (RR) Note: The functionality in the Fixed with Array Preference policy from ESX/ESXi 4.1 was rolled into the Fixed policy in ESXi 5.0 and later. Note: The Most Recently Used (MRU) policy is not an option for Symmetrix devices, because the MRU policy goes against best practices. Note: When you set the NMP policy to Round Robin (RR) for Symmetrix devices, VSI Path Management skips the gatekeeper devices. Best practice dictates that they have a policy of Fixed. For PowerPath/VE, the multipathing policy options depend on the storage class that is selected. For all Symmetrix devices, the multipathing options are: Least Blocks (lb) Least I/O (li) Round Robin (rr) Stream IO (si) Symmetrix Optimization (so) For all CLARiiON and VNX devices, the multipathing options are: Least Blocks (lb) Least I/O (li) Round Robin (rr) Stream IO (si) CLARiiON Optimization (co) Using VSI for vsphere Client 29

30 Using VSI for vsphere Client For all other storage classes (VPLEX and others), the multipathing options are: Least Blocks (lb) Least I/O (li) Round Robin (rr) Stream IO (si) Adaptive (ad) Set Multipathing Policy Summary page This page summarizes the multipathing policy changes that will be made. The VMware vsphere object that is the context of the operation appears, as well as any policy changes for both PowerPath/VE and NMP. When you click the Finish button, the multipathing policy changes are executed on a device-by-device basis. Each policy change for each device represents a task in the vsphere Client Recent Tasks monitor. 30 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

31 CHAPTER 4 Invisible Body Tag VSI Configuration This chapter explains the configuration options available for VSI for VMware vsphere. It includes the following topic: VSI logging VSI Configuration 31

32 VSI Configuration VSI logging VSI for vsphere Client provides a feature logging function for configuring log levels and storing logs. Select Logging from the Settings tree menu to display the logging configuration options. Figure 6 shows an example. The various VSI log files are located on disk at: %APPDATA%\EMC\Virtual Storage Integrator\vSphere4\Logs Setting logging options Figure 6 VSI Feature logging The General\Logging window provides the following options: Select a log file from the Log Files drop-down list for the VSI loaded feature. To view previous log files that are stored by date, clear the Active Logs Only checkbox. Select files by using the Log Files drop-down list. Click the File icon to open the Log files directory: C:\Users\Administrator\AppData\Roaming\EMC\Virtual Storage Integrator\vSphere4\Logs 32 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

33 VSI Configuration Click the Auto-Load icon to enable or disable auto-load. When auto-load is enabled, a log file is monitored and loaded into the viewer as it is modified. Click the Scroll lock icon to enable or disable scroll lock. When enabled, the scroll lock feature causes the log viewer to not automatically scroll to the bottom of the log file whenever it is appended. Click the Search log files icon to open the Find window to search log files for standard or regular expressions. Search can match case, a whole word, or the beginning of a word. Select the Compress file icon to create a zip archive of the log files to save in another location. Log files can be set to one of the following levels by selecting the Log Levels drop-down list: Off No log entries are written. All All log entries are written. Fatal Only fatal errors are written. Error Only error messages are written. Warn Warning and error messages are written. Info All information, including error and warning messages, is written. This is the default value. Debug Informative messages as well as errors and warnings are written for any general operations that occur. VSI Configuration 33

34 VSI Configuration 34 EMC VSI for VMware vsphere: Path Management Version 5.6 Product Guide

EMC VSI for VMware vsphere : Path Management Version 5.3

EMC VSI for VMware vsphere : Path Management Version 5.3 EMC VSI for VMware vsphere : Path Management Version 5.3 Product Guide P/N 300-013-068 REV 03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2012

More information

EMC Secure Remote Support Device Client for Symmetrix Release 2.00

EMC Secure Remote Support Device Client for Symmetrix Release 2.00 EMC Secure Remote Support Device Client for Symmetrix Release 2.00 Support Document P/N 300-012-112 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 SP1 Console Client for Microsoft Windows

EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 SP1 Console Client for Microsoft Windows EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 SP1 Console Client for Microsoft Windows P/N 300-012-249 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000

More information

EMC VSI for VMware vsphere Web Client

EMC VSI for VMware vsphere Web Client EMC VSI for VMware vsphere Web Client Version 6.9.2 Product Guide 302-000-051 REV 13 Copyright 2013-2016 EMC Corporation. All rights reserved. Published in the USA. Published June 2016 EMC believes the

More information

EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 Console Client for Microsoft Windows

EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 Console Client for Microsoft Windows EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 Console Client for Microsoft Windows Installation Guide P/N 300-009-578 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103

More information

EMC VSI for VMware vsphere AppSync Management

EMC VSI for VMware vsphere AppSync Management EMC VSI for VMware vsphere AppSync Management Version 5.4 Product Guide P/N 300-014-772 REV 01 Copyright 2012 EMC Corporation. All rights reserved. Published in the USA. Published September, 2012 EMC believes

More information

EMC Ionix Network Configuration Manager Version 4.1.1

EMC Ionix Network Configuration Manager Version 4.1.1 EMC Ionix Network Configuration Manager Version 4.1.1 RSA Token Service Installation Guide 300-013-088 REVA01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com

More information

EMC SourceOne for Microsoft SharePoint Version 7.1

EMC SourceOne for Microsoft SharePoint Version 7.1 EMC SourceOne for Microsoft SharePoint Version 7.1 Installation Guide 302-000-151 REV 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2009-2013

More information

EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version

EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version Installation and Administration Guide P/N 300-007-130 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000

More information

EMC SourceOne Discovery Manager Version 6.7

EMC SourceOne Discovery Manager Version 6.7 EMC SourceOne Discovery Manager Version 6.7 Installation and Administration Guide 300-012-743 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

EMC VSI for VMware vsphere Web Client

EMC VSI for VMware vsphere Web Client EMC VSI for VMware vsphere Web Client Version 6.2 Product Guide P/N 302-000-051 REV 03 July 2014 Copyright 2014 EMC Corporation. All rights reserved. Published in the USA. Published July 2014 EMC believes

More information

EMC Plugins for VMware vsphere

EMC Plugins for VMware vsphere EMC Plugins for VMware vsphere 1 2 Overview 1.1 Overview 4 1.2 Overview of Test Environment 5 Installation of the VSI Plugins 2.1 Downloading the Virtual Storage Integrator Plugins 10 2.2 Installing the

More information

EMC SourceOne for Microsoft SharePoint Version 6.7

EMC SourceOne for Microsoft SharePoint Version 6.7 EMC SourceOne for Microsoft SharePoint Version 6.7 Installation Guide 300-012-747 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2011 EMC

More information

EMC SourceOne Discovery Manager Version 6.5

EMC SourceOne Discovery Manager Version 6.5 EMC SourceOne Discovery Manager Version 6.5 Installation and Administration Guide 300-008-569 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

EMC NetWorker. Licensing Guide. Release 8.1 P/N REV 02

EMC NetWorker. Licensing Guide. Release 8.1 P/N REV 02 EMC NetWorker Release 8.1 Licensing Guide P/N 302-000-557 REV 02 Copyright 2011-2013 EMC Corporation. All rights reserved. Published in the USA. Published October, 2013 EMC believes the information in

More information

EMC SourceOne for Microsoft SharePoint Version 6.7

EMC SourceOne for Microsoft SharePoint Version 6.7 EMC SourceOne for Microsoft SharePoint Version 6.7 Administration Guide P/N 300-012-746 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2011

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

EMC SourceOne TM Offline Access USER GUIDE. Version 6.8 P/N A01. EMC Corporation Corporate Headquarters: Hopkinton, MA

EMC SourceOne TM Offline Access USER GUIDE. Version 6.8 P/N A01. EMC Corporation Corporate Headquarters: Hopkinton, MA EMC SourceOne TM Offline Access Version 6.8 USER GUIDE P/N 300-013-695 A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2005-2012 EMC Corporation.

More information

EMC Simple Support Matrix

EMC Simple Support Matrix EMC Simple Support Matrix EMC Enterprise Hybrid Cloud 2.5.1 Federation SDDC Edition SEPTEMBER 2015 REV 07 2014-2015 EMC Corporation. All Rights Reserved. EMC believes the information in this publication

More information

EMC SourceOne Management Pack for Microsoft System Center Operations Manager

EMC SourceOne Management Pack for Microsoft System Center Operations Manager EMC SourceOne Management Pack for Microsoft System Center Operations Manager Version 7.2 Installation and User Guide 302-000-955 REV 01 Copyright 2005-2015. All rights reserved. Published in USA. Published

More information

EMC SourceOne for File Systems

EMC SourceOne for File Systems EMC SourceOne for File Systems Version 7.2 Administration Guide 302-000-958 REV 02 Copyright 2005-2015 EMC Corporation. All rights reserved. Published in the USA. Published December 9, 2015 EMC believes

More information

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.

More information

EMC SourceOne Version 7.0

EMC SourceOne Version 7.0 EMC SourceOne Version 7.0 Disaster Recovery Solution Guide 300-015-197 REV 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2012 EMC Corporation.

More information

EMC SourceOne Version 7.1

EMC SourceOne Version 7.1 EMC SourceOne Version 7.1 Disaster Recovery Solution Guide 302-000-180 REV 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2013 EMC Corporation.

More information

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE Applied Technology Abstract This white paper is an overview of the tested features and performance enhancing technologies of EMC PowerPath

More information

EMC Avamar 6.1 for SharePoint VSS

EMC Avamar 6.1 for SharePoint VSS EMC Avamar 6.1 for SharePoint VSS User Guide P/N 300-013-358 REV 06 Copyright 2001-2013 EMC Corporation. All rights reserved. Published in the USA. Published September 2013 EMC believes the information

More information

Dell Storage Compellent Integration Tools for VMware

Dell Storage Compellent Integration Tools for VMware Dell Storage Compellent Integration Tools for VMware Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell EMC NetWorker Module for MEDITECH

Dell EMC NetWorker Module for MEDITECH Dell EMC NetWorker Module for MEDITECH Version 9.2 Installation and Administration Guide 302-003-700 REV 02 Copyright 2007-2017 Dell Inc. or its subsidiaries. All rights reserved. Published August, 2017

More information

EMC NetWorker Module for Microsoft for Hyper-V VSS

EMC NetWorker Module for Microsoft for Hyper-V VSS EMC NetWorker Module for Microsoft for Hyper-V VSS Release 8.2 User Guide P/N 302-000-653 REV 02 Copyright 2007-2014 EMC Corporation. All rights reserved. Published in the USA. Published September 2014

More information

EMC NetWorker Module for MEDITECH

EMC NetWorker Module for MEDITECH EMC NetWorker Module for MEDITECH Version 8.2 Administration Guide 302-000-771 REV 02 Copyright 2007-2014 EMC Corporation. All rights reserved. Published in USA. Published September, 2014 EMC believes

More information

EMC NetWorker. Cloning Integration Guide. Release 8.0 P/N REV A02

EMC NetWorker. Cloning Integration Guide. Release 8.0 P/N REV A02 EMC NetWorker Release 8.0 Cloning Integration Guide P/N 300-013-558 REV A02 Copyright (2011-2013) EMC Corporation. All rights reserved. Published in the USA. Published January 2013 EMC believes the information

More information

Simple Support Matrix

Simple Support Matrix Version REV 07 January 2018 The following tables provide product compatibility information for Classic. This solution uses English language versions of the applications. interoperability and system limits...2

More information

EMC Documentum Archive Services for Reports Version 1.7 SP1

EMC Documentum Archive Services for Reports Version 1.7 SP1 EMC Documentum Archive Services for Reports Version 1.7 SP1 INSTALLATION GUIDE P/N 300-006-542 A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

Dell Storage Integration Tools for VMware

Dell Storage Integration Tools for VMware Dell Storage Integration Tools for VMware Version 4.1 Administrator s Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

EMC ProtectPoint. Solutions Guide. Version REV 03

EMC ProtectPoint. Solutions Guide. Version REV 03 EMC ProtectPoint Version 3.5 Solutions Guide 302-003-476 REV 03 Copyright 2014-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2017 Dell believes the information in this publication

More information

EMC NetWorker. Snapshot Management Integration Guide. Version 9.0.x REV 05

EMC NetWorker. Snapshot Management Integration Guide. Version 9.0.x REV 05 EMC NetWorker Version 9.0.x Snapshot Management Integration Guide 302-001-777 REV 05 Copyright 2001-2016 EMC Corporation. All rights reserved. Published in the USA. Published June 2016 EMC believes the

More information

EMC NetWorker Module for DB2 Version 4.0

EMC NetWorker Module for DB2 Version 4.0 EMC NetWorker Module for DB2 Version 4.0 Administration Guide P/N 300-005-965 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1998-2009 EMC

More information

Dell Storage Compellent Integration Tools for VMware

Dell Storage Compellent Integration Tools for VMware Dell Storage Compellent Integration Tools for VMware Administrator s Guide Version 3.1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

EMC SourceOne Management Version 6.7

EMC SourceOne  Management Version 6.7 EMC SourceOne Email Management Version 6.7 Installation Guide 300-012-741 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2011 EMC Corporation.

More information

HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide

HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide Abstract This guide is intended to assist customers in successfully migrating their VMware ESX/ESXi hosts on HP 3PAR StoreServ storage

More information

EMC ViPR Controller. Ingest Services for Existing Environments Guide. Version REV 01

EMC ViPR Controller. Ingest Services for Existing Environments Guide. Version REV 01 EMC ViPR Controller Version 3.5 Ingest Services for Existing Environments Guide 302-003-280 REV 01 Copyright 2013-2016 EMC Corporation. All rights reserved. Published in the USA. Published October 2016

More information

Dell EMC NetWorker. Snapshot Management Integration Guide. Version REV 02

Dell EMC NetWorker. Snapshot Management Integration Guide. Version REV 02 Dell EMC NetWorker Version 18.1 Snapshot Management Integration Guide 302-004-426 REV 02 Copyright 2001-2018 Dell Inc. or its subsidiaries. All rights reserved. Published July 2018 Dell believes the information

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 SP1 User Guide P/N 302-000-098 REV 02 Copyright 2007-2014 EMC Corporation. All rights reserved. Published in the

More information

EMC Documentum Composer

EMC Documentum Composer EMC Documentum Composer Version 6.0 SP1.5 User Guide P/N 300 005 253 A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748 9103 1 508 435 1000 www.emc.com Copyright 2008 EMC Corporation. All

More information

EMC Exam E RecoverPoint Specialist Exam for Implementation Engineers Version: 6.0 [ Total Questions: 200 ]

EMC Exam E RecoverPoint Specialist Exam for Implementation Engineers Version: 6.0 [ Total Questions: 200 ] s@lm@n EMC Exam E20-375 RecoverPoint Specialist Exam for Implementation Engineers Version: 6.0 [ Total Questions: 200 ] Question No : 1 Which statement is true regarding vrpas? A. vcenter Server is required

More information

EMC ViPR Controller. Integration with VMAX and VNX Storage Systems Guide. Version REV 01

EMC ViPR Controller. Integration with VMAX and VNX Storage Systems Guide. Version REV 01 EMC ViPR Controller Version 2.3 Integration with VMAX and VNX Storage Systems Guide 302-002-075 REV 01 Copyright 2013-2015 EMC Corporation. All rights reserved. Published in USA. Published July, 2015 EMC

More information

EMC Data Domain Boost for Enterprise Applications and EMC ProtectPoint Database Application Agent

EMC Data Domain Boost for Enterprise Applications and EMC ProtectPoint Database Application Agent EMC Data Domain Boost for Enterprise Applications and EMC ProtectPoint Database Application Agent Version 2.5 302-002-363 REV 04 Copyright 2013-2016 EMC Corporation. All rights reserved. Published in the

More information

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA.

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA. This Reference Architecture Guide describes, in summary, a solution that enables IT organizations to quickly and effectively provision and manage Oracle Database as a Service (DBaaS) on Federation Enterprise

More information

EMC Unisphere for VMAX

EMC Unisphere for VMAX EMC Unisphere for VMAX Version 8.2.0 REST API Concepts and Programmer's Guide Copyright 2014-2015 EMC Corporation. All rights reserved. Published in the USA. Published March 31, 2016 EMC believes the information

More information

APPSYNC REPURPOSING COPIES ON UNITY

APPSYNC REPURPOSING COPIES ON UNITY APPSYNC REPURPOSING COPIES ON UNITY Repurposing Block Based Storage Volumes ABSTRACT This white paper discusses and provides guidelines for users who wants to utilize repurposing capabilities of Dell EMC

More information

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide Dell Storage vsphere Web Client Plugin Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

Dell EMC Avamar for SQL Server

Dell EMC Avamar for SQL Server Dell EMC Avamar for SQL Server Version 7.5.1 User Guide 302-004-292 REV 01 Copyright 2001-2018 Dell Inc. or its subsidiaries. All rights reserved. Published February 2018 Dell believes the information

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family Version 4.2 Configuring Hosts to Access Fibre Channel (FC) or iscsi Storage 302-002-568 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July

More information

Dell PowerVault MD Series VMware Storage Replication Adapter (SRA) Installation and Configuration Manual (Web Client)

Dell PowerVault MD Series VMware Storage Replication Adapter (SRA) Installation and Configuration Manual (Web Client) Dell PowerVault MD Series VMware Storage Replication Adapter (SRA) Installation and Configuration Manual (Web Client) Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps

More information

EMC ViPR Controller. Service Catalog Reference Guide. Version REV 02

EMC ViPR Controller. Service Catalog Reference Guide. Version REV 02 EMC ViPR Controller Version 3.5 Service Catalog Reference Guide 302-003-279 REV 02 Copyright 2013-2019 EMC Corporation All rights reserved. Published February 2019 Dell believes the information in this

More information

EMC Centera Centera Seek USERS GUIDE. Version 2.1 P/N REV A02. EMC Corporation Corporate Headquarters: Hopkinton, MA

EMC Centera Centera Seek USERS GUIDE. Version 2.1 P/N REV A02. EMC Corporation Corporate Headquarters: Hopkinton, MA EMC Centera Centera Seek Version 2.1 USERS GUIDE P/N 300-003-639 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006 EMC Corporation. All

More information

Dell EMC NetWorker Module for Microsoft for Exchange Server VSS

Dell EMC NetWorker Module for Microsoft for Exchange Server VSS Dell EMC NetWorker Module for Microsoft for Exchange Server VSS Version 18.1 User Guide 302-004-268 REV 02 Copyright 2007-2018 Dell Inc. or its subsidiaries. All rights reserved. Published August, 2018

More information

TECHNICAL NOTES. Technical Notes P/N REV 01

TECHNICAL NOTES. Technical Notes P/N REV 01 TECHNICAL NOTES Configuring EMC Symmetrix VMAX, EMC NetWorker Module for MEDITECH, and EMC NetWorker Management Console to Perform ISB and IDR Backups Release 8.2 SP1 Technical Notes P/N 302-002-228 REV

More information

Basic Configuration Installation Guide

Basic Configuration Installation Guide EMC RecoverPoint for VMs 5.0 Basic Configuration Installation Guide P/N 302-003-534 REV 01 December 7, 2016 This document contains information on these topics: Revision History... 2 Overview... 3 Reference

More information

EMC Celerra Network Server NS-480 Dense Storage

EMC Celerra Network Server NS-480 Dense Storage EMC Celerra Network Server NS-480 Dense Storage Cabling Verification Guide P/N 300-011-017 REV 01 EMC Corporation Corporate Headquarters: Hopkinton, M 01748-9103 1-508-435-1000 www.emc.com Copyright 2010

More information

EMC DiskXtender Release 6.5 SP8

EMC DiskXtender Release 6.5 SP8 EMC DiskXtender Release 6.5 SP8 Microsoft Windows Version Administration Guide P/N 302-002-314 REV 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

Patch Read Me. EMC Unified Infrastructure Manager/Provisioning Version 4.1 Patch 04. Patch Read Me. P/N Rev 01.

Patch Read Me. EMC Unified Infrastructure Manager/Provisioning Version 4.1 Patch 04. Patch Read Me. P/N Rev 01. EMC Unified Infrastructure Manager/Provisioning Version 4.1 Patch 04 P/N 302-002-521 Rev 01 November 2015 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Table

More information

EMC Documentum Composer

EMC Documentum Composer EMC Documentum Composer Version 6 SP1 User Guide P/N 300 005 253 A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748 9103 1 508 435 1000 www.emc.com Copyright 2008 EMC Corporation. All rights

More information

EMC Storage Monitoring and Reporting

EMC Storage Monitoring and Reporting EMC Storage Monitoring and Reporting Version 4.0 Upgrading to ViPR SRM P/N 302-002-733 REV 03 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published September 2016 EMC believes

More information

Copyright 2012 EMC Corporation. All rights reserved.

Copyright 2012 EMC Corporation. All rights reserved. 1 BUILDING INFRASTRUCTURES FOR THE POST PC ERA Umair Riaz vspecialist 2 The Way We Work Is Changing Access From Anywhere Applications On The Go Devices End User Options 3 Challenges Facing Your Business

More information

SnapCenter Software 4.1. Administration Guide. December _C0 Updated for 4.1.1

SnapCenter Software 4.1. Administration Guide. December _C0 Updated for 4.1.1 SnapCenter Software 4.1 Administration Guide December 2018 215-13391_C0 doccomments@netapp.com Updated for 4.1.1 Table of Contents 3 Contents Deciding whether to read the SnapCenter Administration information...

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

Dell EMC ME4 Series vsphere Client Plug-in

Dell EMC ME4 Series vsphere Client Plug-in Dell EMC ME4 Series vsphere Client Plug-in User's Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Dell EMC NetWorker Module for SAP

Dell EMC NetWorker Module for SAP Dell EMC NetWorker Module for SAP Version 18.1 Administration Guide 302-004-445 REV 01 Copyright 2009-2018 Dell Inc. or its subsidiaries. All rights reserved. Published July 2018 Dell believes the information

More information

EMC Avamar 7.3 for IBM DB2

EMC Avamar 7.3 for IBM DB2 EMC Avamar 7.3 for IBM DB2 User Guide 302-002-846 REV 01 Copyright 2001-2016 EMC Corporation. All rights reserved. Published in the USA. Published April, 2016 EMC believes the information in this publication

More information

EMC Solutions Enabler Symmetrix Open Replicator CLI Version 7.1

EMC Solutions Enabler Symmetrix Open Replicator CLI Version 7.1 EMC Solutions Enabler Symmetrix Open Replicator CLI Version 7.1 Product Guide P/N 300-002-182 REV A07 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 2.0 Data Protection Guide For Windows File Systems January 2017 215-11356_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read this information... 5 SnapCenter

More information

Configuring ApplicationHA in VMware SRM 5.1 environment

Configuring ApplicationHA in VMware SRM 5.1 environment Configuring ApplicationHA in VMware SRM 5.1 environment Windows Server 2003 and 2003 R2, Windows Server 2008 and 2008 R2 6.0 September 2013 Contents Chapter 1 About the ApplicationHA support for VMware

More information

EMC Avamar 7.1 for IBM DB2

EMC Avamar 7.1 for IBM DB2 EMC Avamar 7.1 for IBM DB2 User Guide 302-000-846 REV 02 Copyright 2001-2014 EMC Corporation. All rights reserved. Published in USA. Published December, 2014 EMC believes the information in this publication

More information

RecoverPoint for Virtual Machines

RecoverPoint for Virtual Machines RecoverPoint for Virtual Machines Version 5.0 Administrator's Guide P/N 302-003-374 REV 03 Copyright 2014-2017 Dell Inc. or its subsidiaries. All rights reserved. Published April 2017 Dell believes the

More information

EMC DiskXtender Release 6.4 Microsoft Windows Version

EMC DiskXtender Release 6.4 Microsoft Windows Version EMC DiskXtender Release 6.4 Microsoft Windows Version Administration Guide P/N 300-007-798 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

RecoverPoint for Virtual Machines

RecoverPoint for Virtual Machines RecoverPoint for Virtual Machines Version 5.2 Administrator's Guide 302-005-002 REV 01 Copyright 2017-2018 Dell Inc. or its subsidiaries. All rights reserved. Published July 2018 Dell believes the information

More information

Dell EMC Avamar Virtual Edition for VMware

Dell EMC Avamar Virtual Edition for VMware Dell EMC Avamar Virtual Edition for VMware Version 7.5.1 Installation and Upgrade Guide 302-004-301 REV 01 Copyright 2001-2018 Dell Inc. or its subsidiaries. All rights reserved. Published February 2018

More information

EMC SAN Copy Command Line Interfaces

EMC SAN Copy Command Line Interfaces EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All

More information

Dell EMC Avamar. vsphere Web Client Administration Guide. Version REV 01

Dell EMC Avamar. vsphere Web Client Administration Guide. Version REV 01 Dell EMC Avamar Version 18.2 vsphere Web Client Administration Guide 302-005-122 REV 01 Copyright 2001-2018 Dell Inc. or its subsidiaries. All rights reserved. Published December 2018 Dell believes the

More information

Dell EMC Avamar for SQL Server

Dell EMC Avamar for SQL Server Dell EMC Avamar for SQL Server Version 7.5 User Guide 302-003-931 REV 01 Copyright 2001-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2017 Dell believes the information in this

More information

VPLEX & RECOVERPOINT CONTINUOUS DATA PROTECTION AND AVAILABILITY FOR YOUR MOST CRITICAL DATA IDAN KENTOR

VPLEX & RECOVERPOINT CONTINUOUS DATA PROTECTION AND AVAILABILITY FOR YOUR MOST CRITICAL DATA IDAN KENTOR 1 VPLEX & RECOVERPOINT CONTINUOUS DATA PROTECTION AND AVAILABILITY FOR YOUR MOST CRITICAL DATA IDAN KENTOR PRINCIPAL CORPORATE SYSTEMS ENGINEER RECOVERPOINT AND VPLEX 2 AGENDA VPLEX Overview RecoverPoint

More information

Patch Read Me. EMC Unified Infrastructure Manager/ Provisioning Version 4.1 Patch 02. Patch Read Me. P/ N Rev 01.

Patch Read Me. EMC Unified Infrastructure Manager/ Provisioning Version 4.1 Patch 02. Patch Read Me. P/ N Rev 01. EMC Unified Infrastructure Manager/ Provisioning Version 4.1 Patch 02 P/ N 302-001-250 Rev 01 July 2014 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Table

More information

Dell EMC Avamar for SharePoint VSS

Dell EMC Avamar for SharePoint VSS Dell EMC Avamar for SharePoint VSS Version 18.1 User Guide 302-004-683 REV 01 Copyright 2001-2018 Dell Inc. or its subsidiaries. All rights reserved. Published July 2018 Dell believes the information in

More information

Enterprise Storage Integrator for SAP Landscape Management Storage Adapter

Enterprise Storage Integrator for SAP Landscape Management Storage Adapter Enterprise Storage Integrator for SAP Landscape Management Storage Adapter Version 4.6.8 User Guide 300-014-914 REV 08 Copyright 2013-2017 Dell Inc. or its subsidiaries All rights reserved. Published July

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

EMC ViPR Controller. Create a VM and Provision and RDM with ViPR Controller and VMware vrealize Automation. Version 2.

EMC ViPR Controller. Create a VM and Provision and RDM with ViPR Controller and VMware vrealize Automation. Version 2. EMC ViPR Controller Version 2.3 Create a VM and Provision and RDM with ViPR Controller and VMware vrealize Automation 302-002-205 01 Copyright 2015- EMC Corporation. All rights reserved. Published in USA.

More information

Dell EMC ViPR Controller

Dell EMC ViPR Controller Dell EMC ViPR Controller Version 3.6.2 Ingest Services for Existing Environments Guide 302-004-917 Copyright 2013-2018 Dell Inc. or its subsidiaries. All rights reserved. Published June 2018 Dell believes

More information

Using EMC Celerra Storage with VMware vsphere and VMware Infrastructure

Using EMC Celerra Storage with VMware vsphere and VMware Infrastructure Using EMC Celerra Storage with VMware vsphere and VMware Infrastructure Version 4.0 Connectivity of VMware vsphere or VMware Infrastructure to Celerra Storage Backup and Recovery of VMware vsphere or VMware

More information

Basic Configuration Installation Guide

Basic Configuration Installation Guide RecoverPoint for VMs 5.1 Basic Configuration Installation Guide P/N 302-003-975 REV 1 July 4, 2017 This document contains information on these topics: Revision History... 2 Overview... 3 Reference architecture...

More information

Dell EMC NetWorker Module for SAP

Dell EMC NetWorker Module for SAP Dell EMC NetWorker Module for SAP Version 9.1 Administration Guide 302-003-085 REV 03 Copyright 2009-2018 Dell Inc. or its subsidiaries. All rights reserved. Published April 2018 Dell believes the information

More information

vsphere Host Profiles Update 1 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Host Profiles Update 1 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this

More information

Dell Compellent Storage Center with CommVault Simpana 9.0. Best Practices

Dell Compellent Storage Center with CommVault Simpana 9.0. Best Practices Dell Compellent Storage Center with CommVault Simpana 9.0 Best Practices Document revision Date Revision Comments 1/30/2012 A Initial Draft THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL PURPOSES ONLY,

More information

TECHNICAL NOTES. Technical Notes P/N REV 01

TECHNICAL NOTES. Technical Notes P/N REV 01 TECHNICAL NOTES Configuring EMC VNX, EMC NetWorker Module for MEDITECH, and EMC NetWorker Management Console to Perform VNX-SNAP Backups Release 8.2 Technical Notes P/N 302-001-685 REV 01 January 16, 2015

More information

EMC SourceOne Offline Access Version 7.1

EMC SourceOne Offline Access Version 7.1 EMC SourceOne Offline Access Version 7.1 Installation and Administration Guide 302-000-157 REV 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2010-2013

More information

NexentaStor VVOL

NexentaStor VVOL NexentaStor 5.1.1 VVOL Admin Guide Date: January, 2018 Software Version: NexentaStor 5.1.1 VVOL Part Number: 3000-VVOL-5.1.1-000065-A Table of Contents Preface... 3 Intended Audience 3 References 3 Document

More information

EMC ViewPoint for SAP (4.6, 4.7) Special Ledger Module ADMINISTRATION MANUAL. Version 2.0 P/N REV A01

EMC ViewPoint for SAP (4.6, 4.7) Special Ledger Module ADMINISTRATION MANUAL. Version 2.0 P/N REV A01 EMC iewpoint for SAP (4.6, 4.7) Special Ledger Module ersion 2.0 ADMINISTRATION MANUAL P/N 300-003-495 RE A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Dell EMC vsan Ready Nodes for VDI

Dell EMC vsan Ready Nodes for VDI Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

EMC VNXe Series. Configuring Hosts to Access NFS File Systems. Version 3.1 P/N REV. 03

EMC VNXe Series. Configuring Hosts to Access NFS File Systems. Version 3.1 P/N REV. 03 EMC VNXe Series Version 3.1 Configuring Hosts to Access NFS File Systems P/N 302-000-190 REV. 03 Copyright 2014-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes

More information