StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016

Size: px
Start display at page:

Download "StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016"

Transcription

1 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016 FEBRUARY 2018 TECHNICAL PAPER

2 Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind Software. StarWind LSFS is a trademark of StarWind Software which may be registered in some jurisdictions. All other trademarks are owned by their respective owners. Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, StarWind Software assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. StarWind Software reserves the right to make changes in the product design without reservation and without notification to its users. Technical Support and Services If you have questions about installing or using this software, check this and other documents first - you will find answers to most of your questions on the Technical Papers webpage or in StarWind Forum. If you need further assistance, please contact us. About StarWind StarWind is a pioneer in virtualization and a company that participated in the development of this technology from its earliest days. Now the company is among the leading vendors of software and hardware hyperconverged solutions. The company s core product is the years-proven StarWind Virtual SAN, which allows SMB and ROBO to benefit from cost-efficient hyperconverged IT infrastructure. Having earned a reputation of reliability, StarWind created a hardware product line and is actively tapping into hyperconverged and storage appliances market. In 2016, Gartner named StarWind Cool Vendor for Compute Platforms following the success and popularity of StarWind HyperConverged Appliance. StarWind partners with world-known companies: Microsoft, VMware, Veeam, Intel, Dell, Mellanox, Citrix, Western Digital, etc. Copyright StarWind Software Inc. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of StarWind Software. TECHNICAL PAPER 2

3 Contents Introduction... 4 Pre-Configuring the Servers... 5 Installing File Server Role... 7 Enabling Multipath Support... 8 Downloading, Installing, and Registering the Software... 9 Configuring Shared Storage Discovering Target Portals Connecting Targets Multipath Configuration Creating a Cluster Adding Witness and Cluster Shared Volumes Configuring the Scale-Out File Server Role Sharing a Folder To share a folder: To manage created shares: Conclusion TECHNICAL PAPER 3

4 Introduction This technical paper covers the Highly Available Shared Storage configuration for Scale-Out File Servers in Windows Server It describes how to configure StarWind Virtual SAN, create CSV(s), and build the Scale-out File Server (SoFS) which allows keeping server application data on file shares over SMB protocol and makes files continuously accessible for end users. Providing VSAN reliability, this architecture is designed to ensure file share availability and accessibility for clustered nodes and VMs in the cluster. StarWind Virtual SAN is a hardware-less storage solution that creates a fault-tolerant and high-performing storage pool built for virtualization workloads by mirroring existing server s storage and RAM between the participating storage cluster nodes. The mirrored storage resource, in this case, is treated just like local storage. StarWind Virtual SAN ensures the simple configuration of highly available shared storage for SoFS and delivers the excellent performance and advanced data protection features. This guide is intended for experienced Windows Server users or system administrators. It provides detailed instructions on how to configure HA Shared Storage for Scale-Out File Server in Windows Server 2016 with StarWind Virtual SAN as a storage provider. A full set of up-to-date technical documentation can always be found here, or by pressing the Help button in the StarWind Management Console. For any technical inquiries, please visit our online community, Frequently Asked Questions page, or use the support form to contact our technical support department. TECHNICAL PAPER 4

5 Pre-Configuring the Servers The reference network diagram of the configuration described further in this guide is provided below. NOTE: Additional network connections may be necessary depending on the cluster setup and applications requirements. For any technical help with configuring the additional networks, please, do not hesitate to contact StarWind support department via online community forum, or via support form (depends on your support plan). 1. Make sure that you have a domain controller and you have added the servers we are configuring to the domain. 2. Install Failover Clustering, Multipath I/O features, and the Hyper-V role on both servers. That can be done through Server Manager (Add Roles and Features menu item). TECHNICAL PAPER 5

6 3. Configure network interfaces on each node to make sure that Synchronization and iscsi/starwind heartbeat interfaces are in different subnets and connected according to the network diagram above. In this document, x subnet is used for iscsi/starwind heartbeat traffic, while x subnet is used for the Synchronization traffic. 4. In order to allow iscsi Initiators discover all StarWind Virtual SAN interfaces, StarWind configuration file (StarWind.cfg) should be changed after stopping the StarWind service on the node where it will be edited. Locate StarWind Virtual SAN configuration file (the default path is: C:\Program Files\StarWind Software\StarWind\StarWind.cfg ) and open it with Wordpad as Administrator. Find the <iscsidiscoverylistinterfaces value= 0 /> string and change the value from 0 to 1 (should look as follows: <iscsidiscoverylistinterfaces value= 1 />). Save the changes and exit Wordpad. Once StarWind.cfg is changed and saved, the StarWind service can be started. TECHNICAL PAPER 6

7 Installing File Server Role 5. Open Server Manager: Start -> Server Manager. 6. Select: Manage -> Add Roles and Features 7. Follow the Wizard's steps to install the selected role. NOTE: Restart the server after the installation is completed. TECHNICAL PAPER 7

8 Enabling Multipath Support 8. On cluster nodes, open the MPIO manager: Start->Administrative Tools->MPIO; 9. Go to the Discover Multi-Paths tab; 10. Tick the Add support for iscsi devices checkbox and click Add. 11. When prompted to restart the server, click Yes to proceed. NOTE: Repeat the procedure on the second server. TECHNICAL PAPER 8

9 Downloading, Installing, and Registering the Software 12. Download the StarWind setup executable file from our website by following this link: NOTE: The setup file is the same for x86 and x64 systems, as well as for all Virtual SAN deployment scenarios. 13. Launch the downloaded setup file on the server where you wish to install StarWind Virtual SAN or one of its components. The setup wizard will appear: 14. Read and accept the License Agreement. Click Next to continue. TECHNICAL PAPER 9

10 15. Carefully read the information about new features and improvements. Red text indicates warnings for users who are updating existing software installations. Click Next to continue. 16. Click Browse to modify the installation path if necessary. Click Next to continue. TECHNICAL PAPER 10

11 17. Select the following components for the minimum setup: StarWind Virtual SAN Service StarWind service is the core of the software. It can create iscsi targets as well as share virtual and physical devices. The service can be managed from StarWind Management Console on any Windows computer or VSA that is on the same network. Alternatively, the service can be managed from StarWind Web Console deployed separately. StarWind Management Console The Management Console is the Graphic User Interface (GUI) part of the software that controls and monitors all storage-related operations (e.g., allows users to create targets and devices on StarWind Virtual SAN servers connected to the network). Click Next to continue. TECHNICAL PAPER 11

12 18. Specify the Start Menu folder. Click Next to continue. 19. Enable the checkbox if you want to create a desktop icon. Click Next to continue. TECHNICAL PAPER 12

13 20. You will be asked to request a time-limited fully functional evaluation key, a FREE version key, or a fully-commercial license key sent to you with the purchase of StarWind Virtual SAN. Select the appropriate option. Click Next to continue. 21. Click Browse to locate the license file. Click Next to continue. TECHNICAL PAPER 13

14 22. Verify the installation settings. Click Back to make any changes or Install to continue. TECHNICAL PAPER 14

15 23. Select the appropriate checkbox to launch StarWind Management Console right after the setup wizard is closed. Click Finish to close the wizard. 24. Repeat the installation steps on the partner node. NOTE: To manage StarWind Virtual SAN installed on a Server Core OS edition, StarWind Management Console must be installed on a different computer running the GUI-enabled Windows edition. TECHNICAL PAPER 15

16 Configuring Shared Storage 25. Launch StarWind Management Console by double-clicking the StarWind tray icon. NOTE: StarWind Management Console cannot be installed on an operating system without a GUI. You can install it on Windows Desktop 7, 8, 8.1, 10, and Windows Server 2008 R2, 2012, 2012 R2, 2016 editions including the desktop versions of Windows. If StarWind Service and Management Console are installed on the same server, the Management Console will automatically add the local StarWind node to the console after the first launch. Then, Management Console automatically connects to it using the default credentials. To add remote StarWind servers to the console, use the Add Server button on the control panel. TECHNICAL PAPER 16

17 26. StarWind Management Console will ask you to specify the default storage pool on the server you re connecting to for the first time. Please, configure the default storage pool to use one of the volumes you have prepared earlier. All the devices created through the Add Device wizard will be stored on it. Should you decide to use an alternative storage pool for your StarWind virtual disks, please use the Add Device (advanced) menu item. Press the Yes button to configure the storage pool. Should you require to change the storage pool destination, press Choose path and point the browser to the necessary disk. NOTE: Each array used by StarWind Virtual SAN to store virtual disk images should meet the following requirements: initialized as GPT; have a single NTFS-formatted partition; have a drive letter assigned. On the steps below, you can find how to prepare an HA device for Witness drive. Other devices should be created in the same way. 27. Select either of two StarWind servers to start the device creation and configuration. 28. Press the Add Device (advanced) button on the toolbar. 29. Add Device Wizard will appear. Select Hard Disk Device and click Next. 30. Select the Virtual disk and click Next. TECHNICAL PAPER 17

18 31. Specify the virtual disk name, location, and size and click Next. 32. Choose the type of StarWind device (Thick-provisioned, or LSFS device), specify virtual block size and click Next. TECHNICAL PAPER 18

19 33. Define the caching policy, specify the cache size, and click Next. NOTE: It is recommended to assign 1 GB of L1 cache in Write-Back or Write-Through mode per 1 TB storage capacity if necessary. TECHNICAL PAPER 19

20 34. Define the Flash Cache Parameters policy and size if necessary. Choose an SSD location in the wizard. Click Next to continue. NOTE: The recommended size of the L2 cache is 10% of the initial StarWind device capacity. TECHNICAL PAPER 20

21 35. Specify the target parameters. Select the Target Name checkbox to enter a custom name of the target. Otherwise, the name will be generated automatically based on the target alias. Click Next to continue. 36. Click Create to add a new device and assign it to the target. Then, click Close to close the wizard. 37. Right-click the servers field and click the Add Server button. Add new StarWind Server which will be used as the partner HA node. Press OK and Connect buttons to continue. TECHNICAL PAPER 21

22 38. Right-click the device you have just created and select Replication Manager. The Replication Manager window will appear. Press the Add Replica button. 39. Select Synchronous two-way replication and click Next to proceed. TECHNICAL PAPER 22

23 40. Specify the partner server IP address. Default StarWind management port is If you have configured a different port, make sure to change the Port Number value parameter accordingly. Click Next. TECHNICAL PAPER 23

24 41. Select Heartbeat Failover Strategy and click Next. 42. Choose Create new Partner Device and click Next. TECHNICAL PAPER 24

25 43. Specify the partner device location or the target name of the device if necessary. Click Next. 44. Select synchronization and heartbeat channels for the HA device by clicking the Change network settings button. TECHNICAL PAPER 25

26 45. Specify the interfaces for synchronization and Heartbeat. Click OK. Then click Next. NOTE: It is recommended configuring Heartbeat and iscsi channels on the same interfaces to avoid the split-brain issue. If Synchronization and Heartbeat interfaces are located on the same network adapter, it is recommended to assign one more Heartbeat interface to a separate adapter. TECHNICAL PAPER 26

27 46. Select Synchronize from existing Device as a partner device initialization mode and click Next. 47. Press the Create Replica button. Then click Close to close the wizard. TECHNICAL PAPER 27

28 48. The added devices will appear in the StarWind Management Console. Repeat the steps above to create other virtual disks if necessary. Once all devices are created, the Management Console should look as follows. TECHNICAL PAPER 28

29 Discovering Target Portals This section describes how to discover Target Portals on each StarWind node. 49. Launch Microsoft iscsi Initiator on the first StarWind node: Start > Administrative Tools > iscsi Initiator or iscsicpl from the command line interface. The iscsi Initiator Properties window will appear. 50. Navigate to the Discovery tab. Click the Discover Portal button. In Discover Target Portal dialog box, enter the local IP address TECHNICAL PAPER 29

30 51. Click the Advanced button, select Microsoft iscsi Initiator as your Local adapter and keep Initiator IP as it is set by default. Press OK twice to complete the Target Portal discovery. TECHNICAL PAPER 30

31 52. Click the Discover Portal button once again. 53. In the Discover Target Portal dialog box, enter the iscsi IP address of the partner node and click the Advanced button. TECHNICAL PAPER 31

32 54. Select Microsoft iscsi Initiator as a Local adapter, and select the initiator IP address from the same subnet. Click OK twice to add the Target Portal. TECHNICAL PAPER 32

33 55. Target portals are added on the local node. 56. Go through the same steps on the partner node. TECHNICAL PAPER 33

34 57. All target portals are added to the partner node. TECHNICAL PAPER 34

35 Connecting Targets 58. Launch Microsoft iscsi Initiator on the first StarWind node and click on the Targets tab. The previously created targets should be listed in the Discovered Targets section. NOTE: If the created targets are not listed, check the firewall settings of the StarWind Server and the list of networks served by the StarWind Server (go to StarWind Management Console -> Configuration -> Network). TECHNICAL PAPER 35

36 59. Select a target for the Witness device, discovered from the local server and click Connect. 60. Enable checkboxes like in the image below and click Advanced. Select Microsoft iscsi Initiator in the Local adapter text field. TECHNICAL PAPER 36

37 Select in the Target portal IP list. Click OK twice to connect the target. NOTE: It is recommended to connect the Witness device only by loopback ( ) address. Do not connect the target to the Witness device from the partner StarWind node. 61. Select the target for the CSV1 device discovered from the local server and click Connect. TECHNICAL PAPER 37

38 62. Enable checkboxes like in the image below and click Advanced. 63. Select Microsoft iscsi Initiator in the Local adapter text field. Select in the Target portal IP list. Click OK twice to connect the target. TECHNICAL PAPER 38

39 64. Select the target for the CSV device, discovered from the partner StarWind node and click Connect. 65. Enable checkboxes, like it is shown in the image below, and click Advanced. 66. Select Microsoft iscsi Initiator in the Local adapter text field. TECHNICAL PAPER 39

40 67. In Target portal IP, select the IP address for the iscsi channel on the partner StarWind Node and Initiator IP address from the same subnet. Click OK twice to connect the target. TECHNICAL PAPER 40

41 68. Repeat the above actions for all HA device targets. The result should look like in the picture below. TECHNICAL PAPER 41

42 69. Repeat the steps described in this section on the partner StarWind node, specifying corresponding IP addresses for the iscsi channel. The result should look like in the screenshot below. TECHNICAL PAPER 42

43 Multipath Configuration NOTE: It is recommended configuring different MPIO policies depending on iscsi channel throughput. For 1 Gbps iscsi channel throughput, it is recommended to set Failover Only MPIO policy. For 10 Gbps iscsi channel throughput, it is recommended to set Round Robin or Least queue depth MPIO policy. 70. With Failover Only MPIO policy, it is recommended to set localhost ( ) as the active path. Select a target located on the local server and click Devices. TECHNICAL PAPER 43

44 71. The Devices dialog appears. Click MPIO. TECHNICAL PAPER 44

45 72. Select Fail Over Only load balance policy, and then designate the local path as active. 73. You can verify that is the active path by selecting it from the list and clicking Details. TECHNICAL PAPER 45

46 74. Repeat the same steps for each device on both nodes. 75. Round Robin or Least Queue Depth MPIO policy can be set in the Device Details window. 76. Initialize the disks and create partitions on them using the Disk Management snap-in. The disk devices are required to be initialized and formatted on both nodes in order to create the cluster. NOTE: It is recommended to initialize the disks as GPT. TECHNICAL PAPER 46

47 Creating a Cluster NOTE: To avoid issues during cluster configuration validation, it is recommended to install the latest Microsoft updates on each node. 77. Open Server Manager. Select the Failover Cluster Manager item from the Tools menu. 78. Click the Create Cluster link in the Actions section of the Failover Cluster Manager. TECHNICAL PAPER 47

48 79. Specify the servers that are to be added to the cluster. Click Next to continue. 80. Validate the configuration by running the cluster validation tests: select Yes and click Next to continue. TECHNICAL PAPER 48

49 81. Specify the cluster name. NOTE: If the cluster servers get IP addresses over DHCP, the cluster also gets its IP address over DHCP. If the IP addresses are set statically, you will be prompted to set the cluster IP address manually. Click Next to continue. TECHNICAL PAPER 49

50 82. Make sure that all the settings are correct. Click Previous to change the settings (if necessary): NOTE: If checkbox Add all eligible storage to the cluster is enabled, the wizard will add all disks to the cluster automatically. The device with smallest storage volume will be assigned as Witness. It is recommended to uncheck it before you click Next and add cluster disks and the Witness drive manually. TECHNICAL PAPER 50

51 83. The process of cluster creation starts. Upon completion, the system displays a summary with detailed information. Click Finish to close the wizard. TECHNICAL PAPER 51

52 Adding Witness and Cluster Shared Volumes Follow these steps to add Cluster Shared Volumes (CSV) that are necessary for working with Hyper-V virtual machines: 84. Open Failover Cluster Manager. 85. Go to Cluster->Storage -> Disks. 86. Click Add Disk in the Actions panel, choose StarWind disks from the list, and click OK. 87. To configure the Witness drive, right-click Cluster->More Actions->Configure Cluster Quorum Settings, follow the wizard, and use the default quorum configuration. TECHNICAL PAPER 52

53 88. Right-click the previously added disk and select Add to Cluster Shared Volumes. TECHNICAL PAPER 53

54 Configuring the Scale-Out File Server Role 89. To configure the Scale-Out File Server role, open Failover Cluster Manager. 90. Right-click on the cluster name, then click Configure Role, and click Next to continue. 91. Select the File Server item from the list in High Availability Wizard and click Next to continue. TECHNICAL PAPER 54

55 92. Select Scale-Out File Server for application data and click Next. 93. On the Client Access Point page, in the Name text field, type NETBIOS, the name that will be used to access a Scale-Out File Server. Click Next to continue. TECHNICAL PAPER 55

56 94. Check whether the specified information is correct. Click Next to proceed, or Previous to change the settings. 95. Once the installation is finished successfully, the Wizard should look as shown in the screenshot below. Click Finish to close the Wizard. TECHNICAL PAPER 56

57 96. The newly created role should look as shown in the screenshot below. NOTE: If the role status is Failed and it is unable to Start, please, follow the next steps: TECHNICAL PAPER 57

58 Open Active Directory Users and Computers; Enable the Advanced view if it is not enabled; Edit the properties of the OU containing the cluster computer object (in our case StarWindCluster); Open the Security tab and click Advanced; In the appeared window, press Add (the Permission Entry dialog box opens), click Select a principal; In the appeared window, click Object Types, select Computers, and click OK; TECHNICAL PAPER 58

59 Enter the name of the cluster computer object (in our case StarWindCluster); Go back to the Permission Entry dialog, scroll down, and select Create Computer Objects. Click OK on all opened windows to confirm the changes. Open Failover Cluster Manager, right-click the SOFS role, and click Start Role. TECHNICAL PAPER 59

60 Sharing a Folder To share a folder: 97. Open Failover Cluster Manager. 98. Expand the cluster and then click Roles. 99. Right-click the file server role and then press Add File Share On the Select the profile for this share page, click SMB Share Applications and then click Next. TECHNICAL PAPER 60

61 101. Select a CSV to host the share. Click Next to proceed Type in the file share name and click Next. TECHNICAL PAPER 61

62 103. Make sure that the Enable Continuous Availability box is checked. Click Next to proceed. TECHNICAL PAPER 62

63 104. Specify the access permissions for your file share. NOTE: If you use Scale-Out File Server for Hyper-V, you must provide all Hyper-V computer accounts, the SYSTEM account, and all Hyper-V administrators with the full control on the share and file system. If you use Scale-Out File Server on Microsoft SQL Server, the SQL Server service account must be granted full control on the share and the file system. TECHNICAL PAPER 63

64 105. Check whether specified settings are correct. Click Previous to make any changes or click Create to proceed. TECHNICAL PAPER 64

65 106. Check the summary and click Close to close the Wizard. TECHNICAL PAPER 65

66 To manage created shares: 107. Open Failover Cluster Manager Expand the cluster and click Roles Choose the file share role, select the Shares tab, right-click the created file share, and select Properties. TECHNICAL PAPER 66

67 Conclusion We have configured a two-node fault-tolerant cluster in Windows Server 2016 with StarWind Virtual SAN as a backbone for your HA shared storage. Now, you have a continuously available Scale-Out File Server file share(s) available over SMB protocol that can be used for storing VMs that leave files open for extended periods of time or other purposes. TECHNICAL PAPER 67

68 Contacts US Headquarters EMEA and APAC (UK) (Spain and Portugal) Customer Support Portal: Support Forum: Sales: General Information: StarWind Software, Inc. 35 Village Rd., Suite 100, Middleton, MA USA , StarWind Software Inc. All rights reserved. TECHNICAL PAPER 68

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 DECEMBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software

More information

StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016

StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN AWS EC2 Deployment Guide

StarWind Virtual SAN AWS EC2 Deployment Guide One Stop Virtualization Shop StarWind Virtual SAN AUGUST 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018 One Stop Virtualization Shop StarWind Virtual SAN HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2 MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the

More information

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the

More information

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN of HyperConverged 2 Nodes with Hyper-V Cluster AUGUST 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and

More information

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V.

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. MARCH 2015 TECHNICAL PAPER Trademarks StarWind,

More information

StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016

StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

Quick Start Guide: Creating HA Device with StarWind Virtual SAN

Quick Start Guide: Creating HA Device with StarWind Virtual SAN One Stop Virtualization Shop Quick Start Guide: August 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V MAY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy

StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy One Stop Virtualization Shop StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN Creating Stand-Alone Image File device

StarWind Virtual SAN Creating Stand-Alone Image File device One Stop Virtualization Shop StarWind Virtual SAN Creating Stand-Alone Image File device JULY 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos

More information

StarWind Virtual SAN HA Devices Configuration Changes

StarWind Virtual SAN HA Devices Configuration Changes One Stop Virtualization Shop StarWind Virtual SAN HA Devices Configuration Changes MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are

More information

StarWind Storage Gateway for Backblaze Getting Started

StarWind Storage Gateway for Backblaze Getting Started One Stop Virtualization Shop StarWind Storage Gateway for Backblaze JUNE 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere

StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere One Stop Virtualization Shop StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere MAY 2018 TECHNICAL PAPER V2.0 Trademarks StarWind, StarWind Software and the StarWind and the

More information

StarWind VTL Storage Gateway for Azure and Veeam Installation and Configuration Guide

StarWind VTL Storage Gateway for Azure and Veeam Installation and Configuration Guide One Stop Virtualization Shop StarWind VTL OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, Starind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind Software.

More information

StarWind Virtual SAN Compute and Storage Separated 3 Nodes with VMware vsphere

StarWind Virtual SAN Compute and Storage Separated 3 Nodes with VMware vsphere #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

One Stop Virtualization Shop. StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER

One Stop Virtualization Shop. StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER One Stop Virtualization Shop StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual Tape Library Used with Veritas Backup Exec

StarWind Virtual Tape Library Used with Veritas Backup Exec One Stop Virtualization Shop StarWind Virtual Tape Library SEPTEMBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication One Stop Virtualization Shop StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication JUNE 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide

StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide One Stop Virtualization Shop StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software

More information

StarWind Virtual SAN for vsphere Software RAID Configuration Guide

StarWind Virtual SAN for vsphere Software RAID Configuration Guide One Stop Virtualization Shop StarWind Virtual SAN for vsphere Software RAID Configuration Guide NOVEMBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016

StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016 One Stop Virtualization Shop StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and

More information

StarWind Native SAN Configuring HA File Server for SMB NAS

StarWind Native SAN Configuring HA File Server for SMB NAS Hardware-less VM Storage StarWind Native SAN Configuring HA File Server for SMB NAS DATE: FEBRUARY 2012 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind Native SAN for Hyper-V:

StarWind Native SAN for Hyper-V: This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind Native SAN for Hyper-V: Configuring HA Storage for Live

More information

StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016

StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016 One Stop Virtualization Shop StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016 MAY 2017 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual Storage Appliance Installation Guide with KVM

StarWind Virtual Storage Appliance Installation Guide with KVM One Stop Virtualization Shop StarWind Virtual Storage Appliance APRIL 2017 TECHNICAL PAPER V 1.0 Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind iscsi SAN & NAS:

StarWind iscsi SAN & NAS: This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October

More information

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN. Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN. Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing & Configuring a SQL JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

Quick Start Guide: Creating VTL device with StarWind Virtual SAN

Quick Start Guide: Creating VTL device with StarWind Virtual SAN #1 HyperConverged Appliance for SMB and ROBO Quick Start Guide: Creating VTL device with StarWind Virtual SAN JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the

More information

StarWind Virtual SAN Hybrid Cloud for Azure

StarWind Virtual SAN Hybrid Cloud for Azure One Stop Virtualization Shop StarWind Virtual SAN OCTOBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Appliances Quick Start Guide

StarWind Appliances Quick Start Guide One Stop Virtualization Shop StarWind Appliances Quick Start Guide MAY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi

StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi One Stop Virtualization Shop StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi MARCH 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind Virtual SAN ODX (Off-loaded Data Transfer) Configuration and Performance Tuning Guide

StarWind Virtual SAN ODX (Off-loaded Data Transfer) Configuration and Performance Tuning Guide #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Configuration and Performance Tuning Guide APRIL 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER One Stop Virtualization Shop Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are

More information

StarWind Virtual SAN Getting Started

StarWind Virtual SAN Getting Started #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN JUNE 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5

StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5 One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5 AUGUST 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN. Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2

StarWind Virtual SAN. Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2 #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2 FEBRUARY 2016 TECHNICAL PAPER Trademarks StarWind,

More information

StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters

StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright

More information

StarWind Virtual SAN 2-Node Stretched Cluster on VMware vsphere 6.5

StarWind Virtual SAN 2-Node Stretched Cluster on VMware vsphere 6.5 One Stop Virtualization Shop 2-Node Stretched Cluster on VMware vsphere 6.5 JULY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered

More information

StarWind Virtual SAN Windows Geo-Clustering: SQL Server

StarWind Virtual SAN Windows Geo-Clustering: SQL Server #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Windows Geo-Clustering: SQL Server FEBRUARY 2016 TECHNICAL PAPER EDWIN SARMIENTO, Microsoft SQL Server MVP, Microsoft Certified Master

More information

StarWind iscsi SAN Software: Getting Started with V5

StarWind iscsi SAN Software: Getting Started with V5 StarWind iscsi SAN Software: Getting Started with V5 www.starwindsoftware.com Copyright 2008-2009. All rights reserved. COPYRIGHT Copyright 2008-2009. All rights reserved. No part of this publication may

More information

StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012

StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012 StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind

More information

StarWind Virtual SAN SQL Server HADR using Availability Groups and Failover Cluster Instance

StarWind Virtual SAN SQL Server HADR using Availability Groups and Failover Cluster Instance One Stop Virtualization Shop SQL Server HADR using Availability Groups and Failover Cluster Instance JUNE 2017 TECHNICAL PAPER Written by Shashank Singh Microsoft MVP (Data Platform), MCC and SQL Server

More information

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright

More information

StarWind iscsi SAN & NAS:

StarWind iscsi SAN & NAS: This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind iscsi SAN & NAS: Configuring HA Shared Storage for vsphere

More information

StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS

StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS Cost Effective HA Storage for Critical Business Applications

More information

StarWind Virtual SAN Installing and Configuring SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines

StarWind Virtual SAN Installing and Configuring SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind iscsi SAN Software: ESX Storage Migration

StarWind iscsi SAN Software: ESX Storage Migration StarWind iscsi SAN Software: ESX Storage Migration www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved. No part of this publication may

More information

StarWind Hyper-Converged Platform: Data Sheet

StarWind Hyper-Converged Platform: Data Sheet Hardware-less VM Storage StarWind Hyper-Converged Platform: LAST UPDATED: MAY 2015 Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind iscsi SAN Software: Virtual Tape Library (Part 1)

StarWind iscsi SAN Software: Virtual Tape Library (Part 1) StarWind iscsi SAN Software: Virtual Tape Library (Part 1) www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved. No part of this publication

More information

StarWind Virtual SAN Installing and Configuring a SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines

StarWind Virtual SAN Installing and Configuring a SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing and Configuring a SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines AUGUST 2015 TECHNICAL PAPER BY

More information

StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup

StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved.

More information

StarWind iscsi SAN Software: Using MetaSAN to Share iscsi Volumes

StarWind iscsi SAN Software: Using MetaSAN to Share iscsi Volumes StarWind iscsi SAN Software: Using MetaSAN to Share iscsi Volumes www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved. No part of this

More information

Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center

Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center Dell Compellent Solution Guide Kris Piepho, Microsoft Product Specialist October, 2013 Revisions Date Description 1/4/2013

More information

StarPort iscsi and ATA-over-Ethernet Initiator: Using as RAM Disk Emulator

StarPort iscsi and ATA-over-Ethernet Initiator: Using as RAM Disk Emulator StarPort iscsi and ATA-over-Ethernet Initiator: Using as RAM Disk Emulator www.starwindsoftware.com COPYRIGHT No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

StarWind iscsi Target for Microsoft Windows: Using StarWind iscsi Target and VMware Workstation Virtual Machines

StarWind iscsi Target for Microsoft Windows: Using StarWind iscsi Target and VMware Workstation Virtual Machines Using StarWind iscsi Target and VMware Workstation Virtual Machines May 1, 2007 Rocket Division Software www.rocketdivision.com Copyright Rocket Division Software 2001-2007. All rights reserved. Page 1

More information

StarWind iscsi Target for Microsoft Windows: StarWind and Double-Take

StarWind iscsi Target for Microsoft Windows: StarWind and Double-Take Rocket Division Software Technical Reference Series StarWind iscsi Target for Microsoft Windows: StarWind and Double-Take May 1, 2007 Rocket Division Software www.rocketdivision.com Copyright Rocket Division

More information

Netwrix Auditor. Virtual Appliance and Cloud Deployment Guide. Version: /25/2017

Netwrix Auditor. Virtual Appliance and Cloud Deployment Guide. Version: /25/2017 Netwrix Auditor Virtual Appliance and Cloud Deployment Guide Version: 9.5 10/25/2017 Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment

More information

StarPort iscsi and ATA-over-Ethernet Initiator: Using as DVD-ROM Emulator

StarPort iscsi and ATA-over-Ethernet Initiator: Using as DVD-ROM Emulator StarPort iscsi and ATA-over-Ethernet Initiator: Using as DVD-ROM Emulator www.starwindsoftware.com COPYRIGHT No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Open-E JovianDSS High-Availability Cluster Step-by-Step. Presentation updated: October 2015

Open-E JovianDSS High-Availability Cluster Step-by-Step. Presentation updated: October 2015 Open-E JovianDSS High-Availability Cluster Step-by-Step Presentation updated: October 2015 1 1. Hardware configuration 2. Create new Pool 1. Add write log (SLOG for ZIL) 2. Add Read Cache 3. Add Spare

More information

Quick Start Guide For Ipswitch Failover v9.0.1

Quick Start Guide For Ipswitch Failover v9.0.1 For Ipswitch Failover v9.0.1 Copyright 1991-2015 All rights reserved. This document, as well as the software described in it, is furnished under license and may be used or copied only in accordance with

More information

StarWind Virtual CD: Using as DVD-ROM Emulator

StarWind Virtual CD: Using as DVD-ROM Emulator StarWind Virtual CD: Using as DVD-ROM Emulator www.starwindsoftware.com Copyright 2008-2010. All rights reserved. COPYRIGHT Copyright 2008-2010. All rights reserved. No part of this publication may be

More information

Dell Compellent Storage Center

Dell Compellent Storage Center Dell Compellent Storage Center How to Setup a Microsoft Windows Server 2012 Failover Cluster Reference Guide Dell Compellent Technical Solutions Group January 2013 THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL

More information

Microsoft Clustered Storage Spaces and StarWind Virtual SAN for a Complete Software-Defined Storage Solution

Microsoft Clustered Storage Spaces and StarWind Virtual SAN for a Complete Software-Defined Storage Solution #1 HyperConverged Appliance for SMB and ROBO Microsoft Clustered Storage Spaces and StarWind Virtual SAN for a Complete Software-Defined Storage Solution JANUARY 2015 WHITE PAPER BY JON TOIGO WHITE PAPER

More information

Microsoft Technical Solutions

Microsoft Technical Solutions Microsoft Technical Solutions How To Setup Microsoft Windows Server 2008 Failover Clustering Compellent Corporate Office Compellent Technologies 7625 Smetana Lane Eden Prairie, Minnesota 55344 www.compellent.com

More information

Parallels Virtuozzo Containers 4.6 for Windows

Parallels Virtuozzo Containers 4.6 for Windows Parallels Parallels Virtuozzo Containers 4.6 for Windows Deploying Microsoft Clusters Copyright 1999-2010 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd. c/o

More information

Developing a Complete RTO/RPO Strategy for Your Virtualized Environment

Developing a Complete RTO/RPO Strategy for Your Virtualized Environment #1 HyperConverged Appliance for SMB and ROBO Developing a Complete RTO/RPO Strategy for Your Virtualized Environment NOVEMBER 2014 WHITE PAPER BY GEORGE CRUMP Lead Analyst Storage Switzerland, LLC Virtualization,

More information

EASYHA SQL SERVER V1.0

EASYHA SQL SERVER V1.0 EASYHA SQL SERVER V1.0 CONTENTS 1 Introduction... 2 2 Install SQL 2016 in Azure... 3 3 Windows Failover Cluster Feature Installation... 7 4 Windows Failover Clustering Configuration... 9 4.1 Configure

More information

1.0. Quest Enterprise Reporter Discovery Manager USER GUIDE

1.0. Quest Enterprise Reporter Discovery Manager USER GUIDE 1.0 Quest Enterprise Reporter Discovery Manager USER GUIDE 2012 Quest Software. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide

More information

Virtual Appliance User s Guide

Virtual Appliance User s Guide Cast Iron Integration Appliance Virtual Appliance User s Guide Version 4.5 July 2009 Cast Iron Virtual Appliance User s Guide Version 4.5 July 2009 Copyright 2009 Cast Iron Systems. All rights reserved.

More information

Dell Storage PS Series Administration and Product Overview

Dell Storage PS Series Administration and Product Overview Dell Storage PS Series Administration and Product Overview Dell Storage Hands-on Lab Instructions Total estimated time: varies. This lab consists of multiple non-dependent modules that can be completed

More information

StarWind Virtual SAN Gentle Shutdown with PowerChute

StarWind Virtual SAN Gentle Shutdown with PowerChute Gentle Shutdown with PowerChute JULY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind Software. StarWind

More information

DELL TM PowerVault TM DL Backup-to-Disk Appliance

DELL TM PowerVault TM DL Backup-to-Disk Appliance DELL TM PowerVault TM DL Backup-to-Disk Appliance Powered by Symantec TM Backup Exec TM Configuring the Dell EqualLogic PS Series Array as a Backup Target A Dell Technical White Paper by Dell Engineering

More information

Status Web Evaluator s Guide Software Pursuits, Inc.

Status Web Evaluator s Guide Software Pursuits, Inc. Status Web Evaluator s Guide 2018 Table of Contents Introduction... 2 System Requirements... 2 Contact Information... 2 Installing Microsoft IIS... 2 Verifying Microsoft IIS Features... 9 Installing the

More information

Dell EMC vsan Ready Nodes for VDI

Dell EMC vsan Ready Nodes for VDI Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

Creating a 2 node virtual SQL Server 2008 Cluster Configuration Using Windows 2003 MSCS

Creating a 2 node virtual SQL Server 2008 Cluster Configuration Using Windows 2003 MSCS Creating a 2 node virtual SQL Server 2008 Cluster Configuration Using Windows 2003 MSCS Reference No: Date: 10/08/2010 File Name: Creating a 2 node SQL Server 2008 Cluster Configuration using Windows 2003

More information

QNAP SMI-S Provider for System Center Virtual Machine Manager 2012

QNAP SMI-S Provider for System Center Virtual Machine Manager 2012 QNAP SMI-S Provider for System Center Virtual Machine Manager 2012 About QNAP SMI-S Provider QNAP SMI-S Provider is a required component for the support of System Center Virtual Machine Manager (SCVMM

More information

21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide

21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide 21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

Clustering and Backing Up Hyper-V 2012 R2 with the Oracle ZFS Storage Appliance ORACLE WHITE PAPER APRIL 2016

Clustering and Backing Up Hyper-V 2012 R2 with the Oracle ZFS Storage Appliance ORACLE WHITE PAPER APRIL 2016 Clustering and Backing Up Hyper-V 2012 R2 with the Oracle ZFS Storage Appliance ORACLE WHITE PAPER APRIL 2016 Table of Contents Introduction 3 Target Audience 3 Solution Overview 4 Oracle ZFS Storage Appliance

More information

Parallels Containers for Windows 6.0

Parallels Containers for Windows 6.0 Parallels Containers for Windows 6.0 Deploying Microsoft Clusters June 10, 2014 Copyright 1999-2014 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Parallels IP Holdings GmbH Vordergasse

More information

Deploy the ExtraHop Discover Appliance with VMware

Deploy the ExtraHop Discover Appliance with VMware Deploy the ExtraHop Discover Appliance with VMware Published: 2018-09-26 Published: 2018-09-26 The ExtraHop virtual appliance can help you to monitor the performance of your applications across internal

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

DSI Optimized Backup & Deduplication for VTL Installation & User Guide DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:

More information

SANmelody TRIAL Quick Start Guide

SANmelody TRIAL Quick Start Guide Page 1 SANmelody TRIAL Quick Start Guide From Installation to Presenting Virtual Storage Download the trial software at: SANmelody Trial Software SANmelody TRIAL Quick Start Guide Change Summary August,

More information

Preparing the boot media/installer with the ISO file:

Preparing the boot media/installer with the ISO file: Preparing the boot media/installer with the ISO file: Download and extract the ISO file with your favorite uncompressing/extracting software (for example: 7zip or WinZip programs) to an empty USB Flash

More information

HP LeftHand SAN Solutions

HP LeftHand SAN Solutions HP LeftHand SAN Solutions Support Document Installation Manuals VSA 8.0 Quick Start - Demo Version Legal Notices Warranty The only warranties for HP products and services are set forth in the express warranty

More information

iscsi Storage Appliance Getting Started Guide

iscsi Storage Appliance Getting Started Guide iscsi Storage Appliance Getting Started Guide 2 Copyright 2007 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form

More information

Getting Started with VMware View View 3.1

Getting Started with VMware View View 3.1 Technical Note Getting Started with VMware View View 3.1 This guide provides an overview of how to install View Manager components and provision virtual desktops. Additional View Manager documentation

More information

DELL TM PowerVault TM DL Backup-to-Disk Appliance

DELL TM PowerVault TM DL Backup-to-Disk Appliance DELL TM PowerVault TM DL Backup-to-Disk Appliance Powered by CommVault TM Simpana TM Configuring the Dell EqualLogic PS Series Array as a Backup Target A Dell Technical White Paper by Dell Engineering

More information

StarPort iscsi and ATA-over-Ethernet Initiator: Using as ATA-over-Ethernet Initiator

StarPort iscsi and ATA-over-Ethernet Initiator: Using as ATA-over-Ethernet Initiator StarPort iscsi and ATA-over-Ethernet Initiator: Using as ATA-over-Ethernet Initiator www.starwindsoftware.com Copyright 2008-2009. All rights reserved. COPYRIGHT Copyright 2008-2009. All rights reserved.

More information

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Dell Storage Engineering December 2015 A Dell Deployment and

More information