SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X
|
|
- Tiffany Violet Long
- 5 years ago
- Views:
Transcription
1 SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P e x A. AR- Products E. F. P P P Tools P a x d x A. A. Parts a. Button Head Pozidriv Tapping Screw: Mx0 d. Security Torx Screw: e. M.x Installation AR-E-M c. AR-E AR- C. A. B. F. B. A. B. C. f. A. E. e. C. G. H. D. F. A. b. Button Head Pozidriv c. Slotting Screw:.x0 B. D. Flat Head Hex Socket Screw: Mx A. g. d. C. b x c x Flat Head Cap Philips Tapping Screw: x9. Pull the cables from the square access hole of the mounting plate C. Use a screwdriver to screw the metal plate C to the wall. Take off the plastic mounting plate B from the body A, and pull the cables through the access hole of C and B, then connect to the body A. Assemble plate B with the body A, and embed the water proof strip D onto the plastic side frame. Assemble the body A onto the mounting plate C with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. Use a screwdriver to screw the base F onto the wall. Attach the water proof gasket to the body A, and pull the cables from the square hole of the base F, and connect to the body A. Assemble the body A with the base F. Screw A and F tight with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. G. A. A. b. A. e. f. H. A.+A. D. a. Put on G, and attach A onto the plastic plate A, and screw it with the Allen key and screws (accessories supplied). Put the ring O on the metal frame, and put them together onto the reader A+A, and screw them and buckle up the buckles on the back. Embed the water proof strip D onto the frame side of the base. Following by the install process of AR-E-M.
2 Door Illuminated Touch-panel 0909 Notice. Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.. Cable selection: Use AWG - Shielded Twist Pair to avoid star wiring. Use CAT for TCP/IP connection.. Power supply: Don t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the reader malfunction. The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.. Keypad lock: If E does not link [TCP / IP connection], the E keypad locks about seconds after power transmission.setting will work after E switches to stand-alone mode. Connector Table P P P P P P P P Cable: P Door Relay Common--Point Door Sensor Exit Switch Alarm Relay Power Cable: P RS- for Lift Blue White Purple White White Orange Purple Gray Thick Red Thick Black Thick Green Thick Blue ()DCAmp (N.C.)DCAmp ()DCAmp Transistor Output Max. /00mA (Open Collector Active Low) DC DC 0 RS-(B-) RS-(A+) Cable: P TCP/IP Output Cable: P TTL Serial Port - - Orange White Orange Green White Green - Black White Black Net - T+ Net - T- Net - R+ Net - R- Transistor Output Max. /00mA (Open Collector Active Low) Cable: P P Beeper LED Door Output Wiegand Pink Yellow Brown Blue White Thin Green Thin Blue Beeper Output /00mA, Low Red LED Output /0mA, Max. Green LED Output /0mA, Max. Transistor Output Max. /00mA (Open Collector Active Low) Wiegand DAT: 0 Input Wiegand DAT: Input Cable: P WGB Exit Switch WGB Door Sensor WGA Exit Switch WGA Door Sensor Cable: P Anti-Tamper Switch Purple White Orange White Purple Orange Red Orange Yellow N.C. Wiring Diagram Connect AR-Hto Electric Bolt Connect to Magnet Lock Electric Bolt E Exit Switch DC Magnet Lock DC PB P EIT N.C. PB P EIT DC Push Button DC Push Button
3 SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR Connect AR-Hto Electric Strike Connect to Door Sensor Electric Strike DC DC Alarm PB P EIT P Door Sensor ALM N.C. CTL Relay Outpot Module DC Push Button DC Door Sensor Connect AR-Hto Readers Reader A Reader B WG WG P P WG WG P DC Connect to Door Exit Switch E Electric Bolt Relay Outpot Module Reader A N.C. CTL WG P Door Output WG P PB-A DS-A PB-B DS-B DC P Door Sensor EIT Push Button DC Adding and Deleting Tag Mode/Mode AR-H Adding the Single Tag or the Random tags Input (or Master Code) 9 UUUUU 0000 Get Tag close to RF Area(Present the tag to the controller.) OK (Memory location number) [e.g.] User Address NO.00 and NO.0 have pcs of random tags: Access programming mode Get Tag close to RF Area OK P.S. The First tag has now been added, present the rest of the tags one after the other to add them to the system as well. Adding the Sequential tags Input (or Master Code) 9 UUUUU QQQQQ Get Tag close to RF Area (Present the tag with the lowest number to the controller.) OK (Memory location number) [e.g.] User Address NO.0 to NO.0 have 0 pcs of sequential tags:(~): Access programming mode Get Tag close to RF Area(only use the tag NO.) OK Deleting the Single Tag Deleting All Tags Input (or Master Code) 0 SSSSS 9 EEEEE Input (or Master Code) 9 9 [e.g.] Delete User Address: 000 Access programming mode Deleting a batch of Tags Input (or Master Code) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000~00 Access programming mode Mode At the Mode, User Address = Card Code Adding Tag Deleting All Tags Input (or Master Code) SSSSS EEEEE OK Input (or Master Code) 9 9 [e.g.] Add User Address: 0000~0 Access programming mode OK Tag Information Deleting Tag Input (or Master Code) 0 SSSSS (or 9 )EEEEE OK [e.g.] Delete a tag with card code CARD CODE CARD CODE Access programming mode 0 OK SITE CODE SITE CODE
4 Door Illuminated Touch-panel 0909 Programming A. Entering and Exiting Programming Mode Entering Input or PPPPPP [e.g.] The Default alue=, if already changed the Master Code=, input Access programming mode Exiting Input Changing the Master Code Access programming mode 09 PPPPPPRRRRRR [Input the -digit new master code twice.] [e.g.] If want to changing the Master Code=, input 09 B. Changing the Node ID of Reader Access programming mode 00 NNN MMM AAA BBB [NNN= Node ID: 000~; MMM=E Door NO.:~; AAA=WGA Door NO.:~; BBB=WGB Door NO.:~] C.Setting up the control mode () Access programming mode 0 N [N=//] Mode Support M Networking/ Stand-Alone User Capacity,000 (0~,999) Access Mode.Card only.card and PIN (-digit PIN).Card or User address (-digit) + Individual PIN (-digit individual PIN) Auto-show Duty time Event Capacity 0,000 0 Holidays Duress Time Zone unlimited Lift Anti-passback Control M Stand-Alone, (~).Card only.card and PIN (-digit public PIN= Arming PWD).Card or PIN (-digit public PIN= Duress code) M Networking/,000.Card only.card and PIN (-digit individual PIN) Stand-Alone (0~,999).Card or PIN (-digit individual PIN) Mode the number of users up to, largely because of its read-only CARD CODE, unlike Mode/Mode shall read the SITE CODE and CARD CODE. D. Setting up the password Individual PWD (M/M) Card or PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and PWD:. Input 0000 ] Card and PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and PWD:. Input 0000 ] 0,000 Public PWD (M) PIN only: Access programming mode PPPP [Input -digit PWD, default value: ] Card and PIN: Access programming mode PPPP [Input -digit PWD, default value:, disable PIN: 0000] unlimited E. Anti-pass-back(M/M) Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to monitor not only the access but also exit condition. Enable device Access programming mode 0 U DDD [Please refer to function default value for details.] [e.g.] If the AR-E set to exit reader, WGA set to access reader. Access programming mode [Please refer to function default value for details.] Enable card user Access programming mode SSSSS EEEEE N [N=0 Enable/ N= Disable/ N= Reset] [e.g.] User address from 00 to 00 enable the anti-pass-back function: F. Auto Open Zone Door will keep opening after first man flashing card. When the reader is stand-alone, supporting only sets of auto-open zone by device setting. Auto-open zone can extend up to unlimited sets by Networking. Enable/Disable auto open zone Access programming mode 0 U DDD [Please refer to function default value for details.] [e.g.] If the AR-E set to Enable aut open zone. Access programming mode [Please refer to function default value for details.] Enable/Disable auto open door without presenting card Access programming mode U DDD [Please refer to function default value for details.] [e.g.] If the WG-B set to Enable aut open door without presenting card. Access programming mode [Please refer to function default value for details.] Setting up access time Access programming mode 0 U NN HHMMhhmm H NN: sets of auto-open zone (NN=00~) HHMMhhmm=Starting time to ending time (e.g.: 0000=0:0 to :00) H= days of week + Holiday (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; : enable)
5 SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR G. Lift control Connect with AR-0ROB to control which floors the user will be able to access. [BAUD900] Please refer to below floor chart Single floor Set Floor/ Stop Access programming mode UUUUU LL (G) L L L L L L L L UUUU=User Address LL=Floor number (0~ floor/stop) 0 [e.g.] User address NO. only can reach the elevator to the th floor: 000 Multi floors 0 9 Access programming mode UUUUU G LLLLLLLL 0 9 [UUUUU=User address G: sets of lift control (Input: 0~) LLLLLLLL: 0 9 floors/stop setting (L=0=Disable, L==Enable) 0 9 [e.g.] User address NO. can reach only the th and 0th floor: Access programming mode OK 0 9 H. Setting Up the Arming Conditions: Application:. Arming is enabled. Door open too long: Door is open longer than door relay time plus door close time..alarm system connected. Force open (Opened without a valid user card): Access by force or illegal procedure.. Door position abnormal: When power is off and then on, reader on arming bffore power off. Enable Arming status: Standby Mode Card only Enable all devices Induct valid card Input digit arming code Enter Program Mode Enable all devices: Access programming mode Enable particular device: Access programming mode U Disable Arming status: Standby Mode Card only Disable all devices Induct valid card Input digit arming code 9 There is NO arming mode for M. Factory default armingcode is:. U=Reader unit (0=E, =WGA, =WGB). Restoring Factory Settings Reset all device parameters and user card data Reset all device parameters and user card data: Access programming mode Enable particular device Induct valid card Input digit arming code U Disable particular device Induct valid card Input digit arming code U Card or Passcode Card and Passcode Input digit user address Input Induct valid card Input digit pass digit pass code Input digits code Input digits arming arming code or U code or U Card or Passcode Card and Passcode Input digit user address Input Induct valid card Input digit pass digit pass code Input digits code Input digits arming arming code 9 or U code 9 or U Reset all user card data: Access programming mode 9 9 Reset IP Setting: Press IP Resent Button of main board for few seconds Appendix-Firmware Upgrade Get the upgrade software from SOYAL or our distributor and run UdpUpdater software Execute the software The software is within SOYAL CD or Login the SOYAL web to downloads Update the firmware [Please login the SOYAL web to download the new ISP Firmware.]. Input the Target Address and Port. [Load Fide] open the documents that have the new ISP Firmware. Click the new ISP Firmware and [Open] it. Click [Update Device] to start the firmware update. Till the screen shown [Program Completed]
6 Door Illuminated Touch-panel 0909 IP Setting Turn on your Web Browser and input factory default IP address: If the AR-E of the IP address has changed We must enter the new IP address. Page menu Monitor the on-line computer IP Setting Change the Log-in information Current State Online Status is able to monitor and show which computer is linking on Ethernet Module Show which computer is linking on Ethernet Module. Current IP address of the AR-E. Log-in User Password When you choose the "Networking Setting" or "User Password" at first. Log-in window will pop out and please input At the Factory Default User name: admin Password: No as default value,so please just press OK to log-in admin Networking Setting You will find initial IP Address 9... and check MAC Address is the same as sticker on Ethernet Module device. Please revise IP address you want, and then click Update button. After updating the IP, please re-connect the Web Browser by new IP address. After changed and updated IP to new address, re-connect the Web Browser by new IP address. User Password Change the log-in password to lock the IP setting of Ethernet Module. The password composes of 0 characters at most, it can be either A~Z or 0~9. Max. 0 characters allowed (Composed of A~Z and 0~9)
7 SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR Command List Function Entering programming mode Command PPPPPP Exposition PPPPPP: Master Code, (Default value: ) Mode Exiting programming mode Exiting programming mode and enabling all device into arming status. (Including E, WGA and WGB) Exiting programming mode and U U= Enable target unit (0=E, =WGA, =WGB) enabling each device into arming status. (E, WGA or WGB) Node ID setting 00 NNN MMM AAA BBB NNN= Node ID of E: 00~; MMM= Door number of E M/M AAA= Door number of WGA; BBB= Door number of WGB Door relay time setting 0 U TTT U= Enable target unit (0=E, =WGA, =WGB) TTT= Door relay time (Input 000=Normal open / Input 00~00=~00 sec. / Input 0~09=0.~0.9 sec. ) Alarm relay time setting 0 TTT TTT= Door relay time (Input 000=Normal open / Input 00~00=~00 sec.) Control mode setting 0 N N= Mode: // Arming delay time setting 0 TTT Base on second, range: 00~ Alarm delay time setting 0 TTT Base on second, range: 00~ Master card setting 0 SSSSS EEEEE Input a user or a batch of user as the master card: 00000~999 M/M (For entering programming mode SSSSS= starting user address; EEEEE= ending user address instead of pressing master code) Auto-open zone setting 0 U NN HHMMhhmm U= Enable target unit (0=E, =WGA, =WGB) H NN: sets of auto-open zone (Range: 00~) HHMMhhmm=staring time to ending time (e.g.: 0000=0:0 to :00) : days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun (Input value: 0=disable; =enable) H: Holiday (Input value: 0=disable; =enable) Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code RRRRRR= Repeat the new master code Suspend or delete tags Suspend= 0 SSSSS EEEEE = Suspend; 9 = Delete Delete= 0 SSSSS 9 EEEEE SSSSS= starting user address; EEEEE= ending user address M/: Recover tag SSSSS EEEEE Recover the paused tag M/M M: Setting up a batch of users SSSSS EEEEE SSSSS=starting Card Code; EEEEE= ending Card Code M to access by card only Setting up the PWD/PIN UUUUU PPPP UUUUU= user address; PPPP=-digit individual PWD M/M (Access mode: Card or PIN) Setting up the PWD/PIN UUUUU PPPP UUUUU= user address; PPPP=-digit individual PWD M/M (Access mode: Card and PIN) Arming output setting TTT Base on ms, range:~, default value=0, Input 0= Timeless M/M: Duress code setting PPPP PPPP=-digit PWD M/M M: Public PIN setting (P.S. Duress code will be unavailable and as public PIN at M (Card or PIN) access mode Card or PIN of M) (Default value=; disable PIN=0000) M/M: Arming PWD setting PPPP PPPP=-digit PWD M/M M: Public PIN setting (Default value=; disable PIN=0000) M (Card and PIN) Enabling or Disabling into arming Flashing a valid card and input NNNN=-digit arming PWD status NNNN U=Enable target unit (0=E, =WGA, =WGB) Enabling or Disabling target unit Flashing a valid card an input into arming status NNNN U Enabling all units into arming Flashing a valid card and input status NNNN Disabling all units into arming Flashing a valid card and input status NNNN 9
8 Door Illuminated Touch-panel 0909 Function Door close time Adding tags by induct Factory setting- Lift control setting: multi-doors Add/Delete tags by closing tags into RF area (M only) AR-0RO/ AR-0ROB relay time setting Factory setting- Real time clock setting Anti-pass-back (Enable user) Lift control setting: single door Duress Function and Arming output setting Delete all tag Same tag reading interval time Auto ring the clock alarm schedule Holiday Setting Function Default alue Command TTT 9 UUUUU QQQQQ 0 U DDD UUUUU G LLLLLLLL N MMM TTT U DDD YYMMDDHHMMSS SSSSS EEEEE P UUUUU LL FFF 9 9 TTTT SS HHMMTT H MMDD F Exposition Base on second, range: 000~, default value: sec. UUUUU= User address; QQQQQ= the amount of card U=Enable target unit (0=E, =WGA, =WGB) DDD=Function default value (Please refer to function default value for details) UUUUU=User address G: groups of lift control (Input range: 0~) LLLLLLLL: floors/stop setting (0=Disable, =Enable) N=0=Delete tag; N==Add tag Close tag into RF area one by one. MMM= Node ID of lift controller TTT= relay time: 000~00=~00 sec. U= Enable target unit (0=E, =WGA, =WGB) DDD= Function default value (Please refer to function default value for details) YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec. SSSSS=starting user address; EEEEE=ending user address P=0=Enable; P==Disable; P==Initial UUUUU=User Address; LL=Floor number (0~ floor/stop) Arming output: FFF= 00 (default value) Duress Function: FFF= 000 Base on 0ms, range from 0 to 000 SS= sets auto alarm schedule, range 0~ HHMM= HH:MM (ex. 00: Ring bell at 0:0) TT=Period of time to ring bell (Base on second, range 0~99 sec.) : days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun (Input value: 0=disable; =enable) H: Holiday (Input value: 0=disable; =enable) MM= Month of year (0=Jan...0=Oct.) DD= Date of month (0=st day of month) F= 0:Del; : Add 0 U DDD Default alue Function Option alue Application Time Attendance Auto Re-lock Auto Open 0: Yes 0: Disable 0: Disable : No : Enable : Enable Networking When Access Mode is "Card and PIN", Readers can skip pressing PIN code. 0: Disable : Enable 00 Exit by Push Button Enable force Open As Access/Exit Reader Anti-pass-back 0: Disable 0: Slave 0: Exit 0: Disable : Enable : Mater : Access : Enable Networking Networking Networking [e.g.] DDD value of AR-E to Enable "Auto Open" + "Exit by Push Button" + "Anti-pass-back" =00+0+= As a result of that, the command will be 0 0 Mode M/M M/M M M/M M/M M/M M/M U DDD Default alue Function Option alue Application Stop Alarm by... Open door immediately without st card presented at auto open zone. 0: None 0: Disable : Push button/ Door Closed : Enable 0 U = Enable target unit (0=E, =WGA, =WGB); DDD = alue SOYAL To have more detailed information, E-learning, and Q&A, please visits our website. Thanks for You
SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X)
SOYAL ACCESS CONTROL SYSTEM AR- (E-V) V0 Contents AR- (E-V-M) Products User Guide Terminal Cables Tools P P P c x d x A. B. C. D. P P P P AR- (E-V) Products User Guide Terminal Cables Tools P P P e x A.
More informationECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C.
EC-ACC90IP-/P Contents EC-ACC90IP- Products User Guide Terminal Cables Tools P P P a x A. E. F. P P P P EC-ACC90IP-P Products User Guide Terminal Cables Tools P P P b x A. B. C. D. P P P P c x Parts Description
More informationSOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M
SOYAL AR-H/AR-H/ AR-H/ ACCESS CONTROL SYSTEM Contents AR-H [Metal Case] Product Water proof Strip d x AR-H Product f x AR-H [Illuminated Touch-panel] AR-H-M Products c x e x A. B. C. D. AR-H Products f
More informationAR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)
AR- (H) / AR- (H)/ AR-(H) / AR- (H) / AR- (H) SOYAL ACCESS CONTROL SYSTEM V0 Contents AR- (H):Touch-panel Metal Housing Product User Guide Terminal Cables Tools Water proof Strip d x P P P P AR- (H):Touch-panel
More informationSOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter
SOYAL AR-H/AR-H/ AR-H/AR-H/AR-H ACCESS CONTROL SYSTEM Contents AR-H [Touch-panel Metal Housing] Product User Guide Terminal Cables Water proof Strip d x AR-H [Touch-panel Metal Housing]/ AR-H-S [Metal
More informationAR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function.
SOYAL ACCESS CONTROL SYSTEM AR- (EF) V00 Contents Product User Guide Terminal Cables Tools Optional P P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 WG keyboard AR-(EF-DO) Installation
More informationOption. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption
SOYAL ACCESS CTROL SYSTEM AR-E V0 Contents Product User Guide Panel Mounting Base WG Key-panel Reader Option AR-0B-X Fit mm DIN Rail or Mount directly AR-K AR-K AR-K Option For Stand-alone Command Setting
More informationSOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools
SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Contents Product Terminal Cables Tools Accessories Option P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 AR-(E) AR-(EF) P P P Security Torx Wrenches
More informationBiometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange
SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables
More informationP4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input
SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide
More informationAR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud
More informationFunction Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.
Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationAR-727H. Technical Manual. 26 August Version 1.00
AR-727H Technical Manual 26 August 2008 Version 1.00 Southern Office: Raytel House Brook Road Rayleigh Essex, SS6 7XH Tel: (01268) 749310 Fax: (01268) 749315 Northern Office: Unit 3 Block 5 Oakbank Industrial
More informationQUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationPartizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating
1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationAR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers
AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationEZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL
EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out
More informationInstruction Manual. Vogue. Security. Technology. Innovation 2013-V01
Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationQuick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0
Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7
More informationOperation manual For NG BIOSINGLE Version 1.1
Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,
More informationW3-H Waterproof Keypad/Reader/Controller
W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark
More information2M IR Mini Dome Quick Installation Guide
1 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical overview.
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More informationQuick Start Guide. GV-CS1320 Camera Access Controller
Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationSF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014
SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationF3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K
F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More informationZAVIO Outdoor IR Mini Dome. Quick Installation Guide
ZAVIO Outdoor IR Mini Dome Quick Installation Guide 0 Quick Installation Guide Please follow the installation steps below to set up your IP Camera. Check the package contents with the list below. See P.1
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationUser Manual. Split access control with intelligent secured power supply.
User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.
More informationFingerprint Identification Proximity Reader. Quick Installation Guide
Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor
More informationW Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2
W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationGV-Card Reader. User s Manual
GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights
More informationWiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader
Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader www.grantsautomation.com.au grant@grantsautomation.com.au Wiring Diagrams for MAW6 Digital Keypad For Pedestrian
More informationPanoramic Fisheye IP Camera. Quick Installation Guide
Panoramic Fisheye IP Camera Quick Installation Guide 8608595330000 Please follow the installation below steps to set up Panoramic Fisheye IP Camera. Check the package contents against the list below.see
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:
ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationW3-M. Metal waterproof standalone access control/reader. User Manual
W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,
More informationWELCOME. For customer support or any inquiries, please visit our web site at or contact us at
WELCOME Congratulations on purchasing the GBF Smart Four Wire Intercom System. Our factory engineers were the first to enable multiple security cameras being monitored through a smart mobile device and
More informationThis document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.
F18 User Manual Version: 1.0 Date: Dec. 2011 Introduction: This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product. About this manual 1. Not all the devices
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationSL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.
SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationSafety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate
www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationINSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control
STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully
More informationInstallation & User Manual
Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationCC Series metal access control Manual
CC Series metal access control Manual 1.Description CC Series is a standalone for two doors, support card, pin, card+pin access way. It is with 2 relays to control 2 doors and supports up to 2000 users
More informationTwo-door Access Controller
Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following
More informationHSY-S209 EM Metal waterproof access control system User Manual
HSY-S209 EM Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1. Product Profile The product is Contact-less inductive card Metal Password Access Controller,
More informationKP2000E/EM Series Style Keypad
23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact
More information180 Series Keypad. Handbook. Revision 2.1
180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique
More informationInstallation & User Manual V2.08
YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment
More informationSYRIS SY110SA. Operating Manual. Ver:1.60
SYRIS SY110SA Operating Manual Ver:1.60 Apr.15.2006 Table of content TABLE OF CONTENT...2 INTRODUCTION...- 1 - Ⅰ. DO DEFAULT CONTRAST TABLE...- 1 - Ⅱ. DI DEFAULT CONTRAST TABLE...- 1 - Ⅲ. OPERATION...-
More informationP6210 PN: 86085A A
P6210 1 PN: 86085A1000010 86085A1000000 Zavio P6210 Quick Installation Guide Please follow the installation steps below to set up P6210 Pan/Tilt IR Dome IP Camera. Check the package contents against the
More information2M Outdoor Motorized Bullet Camera
2M Outdoor Motorized Bullet Camera 8608586000010 Quick Installation Guide Please follow the installation steps below to set up your 2MP Bullet IP Camera. Check the package contents against the list below.
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More informationFingerprint Access Standalone User s Manual
Fingerprint Access Standalone User s Manual V1.1.1 1 Table of Contents 1 Overview... 1 2 Device Structure and Installation... 2 2.1 Device Structure... 2 2.2 Device Installation... 3 3 System Structure...
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX
ISC910-1-0-GB-XX ISC911-5-0-GB-XX ISC920-0-0-GB-XX ISC921-5-0-GB-XX The ImproX IXP20 is a fully featured, stand-alone Access Control System supporting up to 1 000 Tagholders and 5 000 transactions. Designed
More informationEncoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.
Encoder Firmware V4.06.09 User s Manual Outdoor PTZ Camera Hardware Manual KCM-8211 2013/05/09 1 Table of Contents Precautions... 3 Introduction... 4 List of Models... 4 Package Contents... 5 Safety Instructions...
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More informationD4210 PN: 86085A
D4210 1 PN: 86085A2000000 Zavio D4210 Quick Installation Guide Please follow the installation steps below to set up D4210 IR Dome IP Camera. Check the package contents against the list below. See P.1
More informationVANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD
VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start
More information212iL Rev. 1.1
212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated
More informationSecurity at Fingertips
Security at Fingertips www.esslsecurity.com Contents 1. Operating Instruction... - 1-1.1 Abbreviated Operating Procedures... - 1-1.2 Introduction to Fingerprint Recognition technology... - 2-1.3 About
More informationDG Series. Access Control Proximity Readers DG-160 DG-800
DG Series Access Control Proximity Readers DG-800 + DG-160 + Features: Applicable card modeem Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access ModesUse Bluetooth smartphone,
More informationClick Save to return to the main Setup screen.
ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationInstallation and User Manual
S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support
More informationOperating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL
Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code
More informationINSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A
www.supremainc.com INSTALLATION GUIDE English Version 2.10 EN 101.00.BLN V2.10A Contents Safety Instructions... 3 Getting Started... 5 Components... 5 Part names and features... 6 Cables and connectors...
More informationInstallation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B
Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its
More informationF7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions
F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationPRO3200 Professional Modular Access Control Hardware
PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...