Crane Control Contactors and Relays
|
|
- Erica Brown
- 6 years ago
- Views:
Transcription
1 October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver as illustrated in Figure 5. Pressure terminals permit quick installation of up to two # wires, solid or stranded, per terminal. The molded operating coils provide maximum protection against moisture and mechanical abuse. Basic -Contact Type KC Relay The Type KC line of control relays complements the mill-type, front connected DC contactors (Bulletin 7, Type K). Each device is completely assembled and ready for mounting on metal panels without additional insulators or special hardware. These dc mill type relays are designed for heavy industry service and are suitable for use on moving machinery. They are arranged for steel panel mounting with front connections. Unit circuit blocks have two captive mounting screws and are interchangeable between relays. They are easily convertible from normally open to normally closed or vice versa. Visible contacts are of double break design. Figure 5. Contact Conversion Features Slide Movable Contact Out are easily field convertible from NO to NC operation and vice versa. Melamine molded contact blocks feature wear-resistant nylon guides and stainless steel springs. Retained knife-edge design for reliable alignment. rated 5 amperes continuous. No adjustments to maintain armature spring and air gap are fixed. Encapsulated coils feature pressure type saddle terminals. Basic relays are available with,, 6 or 8 contacts. All relays in the line have same mounting dimensions. Flip Over and Insert Contact Standards and Certifications NEMA ICS-... NEMA ICS-5.. Technical Data and Specifications Voltage: 6 Vdc maximum. Operation: Magnetic. Mounting: Steel panel. Electrical Ratings: 5 amperes continuous. amperes inductive breaking at 5 V. amperes inductive breaking at V CA58E
2 76 DC Relays Type KC Heavy-Duty Mill Accessories Table 7. ac/dc Rectifier Kits 5/6 Hertz AC Supply Voltage For operating relay from ac supply voltage. Dimensions Figure 6. Approximate Dimensions in Inches (mm) Table 8. Type KC Relay Coil Required Part 95 Vdc C8EB Series (7.6) Side.5 (.) (6.) (5.) Mtg. Holes End Slots for /6" Screws Front Approximate Dimensions in Inches (mm).88 (7.) (.) 7 (9.5) 8. (.) 5.9 (.8) (5.) hen Ordering Specify of relay from Table 9. Table 9. Type KC Heavy-Duty Mill Relays of Contact Arrangement Open Type Relay NO NC Part A7-75- A7-75- A7-75- A7-75- A7-75- A7-75- A7-75- A A7-75- A7-75- A7-75- A7-75- A A7-75- A7-75- A7-75- A7-75- A October 8 Price includes assembled relay complete with operating coil rated V. Consult factory for other voltage ratings. The maximum number of NC contacts satisfactorily operated by the magnet is. Discount Symbol CD- Consult Sales Office for Pricing CA58E
3 October 8 DC Relays Types KPR & KFL Special Application 77 Technical Data and Specifications Voltage: Maximum 6 Vdc. Operation: Magnetic. Mounting: Steel panel or insulated panel Dimensions Contact Ratings: 5 amperes at V amperes at V Duty: Continuous. DC Plugging Relay Type KPR Plugging The Type KPR Relay features a diode assembly mounted on the relay base and wired in series with the relay operating coil. The relay detects when a dc motor is being plugged. (Plugging is the sudden reversal of the polarity applied to a relay motor causing it to rapidly stop and reverse rotational direction.) The coil circuit of the plugging relay is connected to parallel with the motor armature and monitors armature voltage. During normal dc motor operation, the diode is non-conducting and the relay is de-energized. During motor plugging, polarity reverses, causing the diode to conduct and operate the relay. The contacts of the relay cause motor circuit contactors and resistors to properly plug the motor. Type KFL Field Loss The Type KFL relays are no longer manufactured. The suggested replacement is the Type 9 single-pole normally open relay. Refer to Page 7 for application and ordering information. Standards and Certifications NEMA Standard NEMA Standard NEMA Standard Figure 7. Approximate Dimensions in Inches (mm) Table. Type KPR Plugging Description hen Ordering Specify Complete Catalog or Table. Type KPR Plugging Relay (Open Type) Approximate Dimensions in Inches (mm) T Type KPR- Relay (8.6) Type KPR- Relay.87 (7.9) (69.9) Motor Voltage Vdc 55 Vdc Vdc 55 Vdc (5.) T Mtg. Holes and Slots for /6" Screws Relay Type KPR- KPR- KPR- KPR- 5.9 (.8) (5.) Catalog 7UD- 7UD-55 7UE- 7UE-55.6 (7.6) Front Side Approximate eight lbs. (5. kg) KPR- relays are for -step or graduated plugging. Consult factory for application details..5 (.) (6.) Discount Symbol CD- Consult Sales Office for Pricing CA58E
4 78 DC Timing Relays 7 VTH & 7 CTH October 8 Table. Challenger Bulletin 7 VTH Timing Relay Data (Sorted by Old ) Timing (Seconds) Old New Timing Relay Replacement The replacement Type 7 heavy-duty DC relays provide adjustable ON-delay timing factory set to duplicate the time delay provided by the previous type CTH and VTH timers. These relays are supplied with equivalent pilot duty contact ratings and configuration A7-69- A7-69- A7-69- A7-69- A A A A7-69- A7-69- A7-69- A7-69- A7-69- A7-69- A A A A7-69- A7-69- A7-69- A7-69- A7-69- A7-69- A A A A7-69- A7-69- A7-69- A7-69- A7-69- A7-69- A A A A7-69- A7-69- A A A A A A A A A A A A A A A A A A ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED5 7ED5 7ED5 7ED5 7ED5 7ED5 7ED6 7ED6 7ED6 7ED7 7ED7 7ED7 7ED7 7ED7 7ED7 7ED8 7ED8 7ED8 7ED9 7ED9 7ED9 7ED9 7ED9 7ED9 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED Discount Symbol CD- Consult Sales Office for Pricing CA58E
5 October 8 DC Timing Relays 7 VTH & 7 CTH 79 Table. Challenger Bulletin 7 CTH Timing Relay Data (Sorted by Old ) Timing (Seconds) Old New A7-69- A7-69- A7-69- A7-69- A A A7-69- A7-69- A7-69- A7-69- A A A7-69- A7-69- A7-69- A7-69- A A ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED 7ED5 7ED5 7ED5 7ED5 7ED5 7ED5 Discount Symbol CD- Consult Sales Office for Pricing CA58E
Crane Control Class 9004
Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................
More informationDescription Page Number PM AC Relays PM DC Relays
Index Relays Description Page Number General Information... PM AC Relays PM Convertible, PMA, PMF, AC Relays... PM Latching, PML, PMAL, AC Relays... 5 Pole Arrangement, Diagrams, PM, PMA, PMF... 6 Dimensional
More informationContacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay
Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationBulletin 700-P, 700DC-P Industrial Relays
Bulletin 700-P, 700DC-P Industrial Relays Adder Decks Description No. of N.O. Contacts Continuous Carrying Current [A] Arrangement Second Deck (0-pole) 0 700-PB00 Second Deck 700-PB40 Second Deck (4-pole)
More informationLatching, Sequence and Impulse Relays Application Data
Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation
More informationAllen-Bradley Drives
Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact
More information3.7. Control Relays and Timers.
Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................
More information3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description
Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................
More information78 Series Electromechanical Relay Selection Guide
78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5
More informationSSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:
41-766.7 SSV-T and SSC-T High Drop-out Relay device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the
More informationC 2 5 D N A A A
Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,
More informationK-Line Mini - Contactors, Overload Relays and Accessories
K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters
ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationSensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52.
Retroreflectors Sensor Accessory AC Sensor Tester/Demonstrator Pilot Device E65 Control Unit.1 Retroreflectors and Retroreflective Tape Product............................................. 414 Application..........................................
More informationControl Transformers Control transformers
Control Transformers It is often desirable to operate the control circuit at a lower voltage than the power circuit. Control transformers are used to step a voltage down to a lower level. Siemens Class
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationBulletin 700-P, 700DC-P Industrial Relays
Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700 P Direct Drive Convertible Contact Cartridge Relays NEMA and IEC ratings 600V maximum AC/DC Accessories for field installation: contact cartridges,
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock
More informationBulletin 700-HA Tube Base Relay
Bulletin 700-HA Tube Base Relay Bulletin 700 HA Tube Base Relay 10 A contact rating DPDT, 3PDT Pin-style terminals Standard ON/OFF flag indicator Options: LED, push-to-test and manual override, socket-mounted
More informationIce Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...
Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in
More informationSpecifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.
Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.4 kv and 25 kv) Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet 150
More informationCat. No. (Spring Clamp. Input Voltage
Bulletin -HL Product Overview/Product Selection Product Selection Bulletin -HL "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationTeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationExercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION
Exercise 1-4 Contactors and Control Relays EXERCISE OBJECTIVE Identify the characteristics of control relays and contactors. DISCUSSION OUTLINE The Discussion of this exercise covers the following points:
More informationELECTRICAL CONTROL SYSTEM COMPONENTS
Module - 2 ELECTRICAL CONTROL SYSTEM COMPONENTS Lecture - 1 MECHANICAL SWITCHES Shameer A Koya EEET 221 : Electrical Control Systems. Module 2 - Objectives State the functions of control system components
More informationBulletin 871D Cylinder Position Inductive Style
Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationOwner s Manual SGA 100 And SGA 100C NOTE NOTE. 1. Safety Symbol Definitions. 2. Weld Control Specifications. 3. Duty Cycle
Owner s Manual SGA 100 And SGA 100C October 2001 FORM: OM-190 753H Use above FORM number when ordering extra manuals. 1. Safety Symbol Definitions Warning! Watch Out! There are possible hazards as shown
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationH3CA-8H-AC/100/110/120
Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat
More informationALLEN BRADLEY RELAY Bulletin 700-HF
ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationOrdering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel
I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2
More informationBulletin 700-HL 2-Pole Terminal Block Relay
Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationonlinecomponents.com
ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary
More informationFor hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T
For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T Presentation XCR With head for rotary movement operators, spring return to off position (1 contact
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationFile E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany
File E156943 Project 00ME17885 December 18, 2000 REPORT on COMBINATION CONTROLLERS Siemens AG Amberg, Germany Copyright 2000 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the
More informationControl, Timing + Ice Cube Relays
... 2 Technical Information... 14 CS8... 18 Technical Information... 21 RZ7-FS Electronic... 24 Technical Information... 34 RZ7-FE Electronic... 36 Technical Information... 42 Relpol Ice Cube Relays R2/R4
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More information1510 MOTOR CONTROLLERS
SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More information24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN
Safety Interlock Switches TL8012-S Versatile Safety Interlock Switch with Guard Door Locking High locking force of 2000 N (450 lb.) locks guard door shut until machine is safe to enter NEMA 6 enclosure
More informationOrdering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel
I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2
More informationSwitching Frequency Test Conditions (AC3/AC4/AC53-a)
Information Common to the G3J-T, G3J-S, and G3J CSM_G3J-T_G3J-S_G3J_common_DS_E_2_2 Engineering Data Load Current vs. Ambient Temperature Load current Io (A) G3J-T217BL G3J-T211BL G3J-S211BL G3J-211BL
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationIEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton
K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 850R miniature control relays 850RS4 standard 850RS24 low level 850RS34 hermetically sealed Catalog 204 Contents Class 850R miniature control relays bbspecifications....................................................
More informationDifferential Liquid/Gas Pressure Transmitter
Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with
More informationTABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description
9 Bulletin 700-HA Bulletin 700-HA 10 A Rating DPDT 3PDT Pin Style Terminals Standard ON/OFF Flag Indicator Finger Grips for Easy Installation and Removal Optional Manual Operator Optional Pilot Light Optional
More informationTongue Switches Trojan 5 & 6
Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationProject Planning. Module 4: Practice Exercises. Academic Services Unit PREPARED BY. August 2012
Project Planning PREPARED BY Academic Services Unit August 2012 Applied Technology High Schools, 2012 Module Objectives Upon successful completion of this module, students should be able to: 1. Select
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More information52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C
Selection Guide Osiswitch Classic Design Classic Catalog number XCKM XCKL XCKJ Enclosure Metal Fixed or plug-in body, -4 C (-4 F) Features 3 conduit entries or +2 C (+248 F) versions Modularity Head +
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable f padlocks) E-FA Painted Steel Enclosure
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name
More informationCP30F Series Circuit Protector for Improving Safety and Wiring Workability
CP30F Series Circuit Protector for Improving Safety and Wiring Workability EMURA, Takeshi * A B S T R A C T A circuit protector is a circuit-breaker that possesses both overcurrent protection and switch
More information3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.
General 1-2-Opto-electronics 3-Interlock Description The Cadet 3 is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.
More informationBulletin 871L & 872L Limit Switch Style
Bulletin 871L & 872L Description Bulletin 871L and 872L inductive proximity sensors are selfcontained, general purpose, solid state devices designed to sense the presence of metal objects (ferrous and
More informationProduct Description. Selector Switches
-100 F SS Vol. 2, Ref. No. [0770] Contents Description Page Product Description......... -100 Features................... -100 Standards and Certifications............. -100 Technical Data..............
More informationCONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual
506 and 507 Relay Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationTransistor drive 2c/4c 5A slim power relays
Transistor drive c/c 5A slim power relays NC RELAYS NC Flat type () NC (Plug-in type) RoHS compliant NC Flat type () NC () FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic
More informationInductive and Capacitive Proximity Sensors Identification Codes. Product Type/Size Output Type of Sensing Options Group of Housing Output Distance
Proximity Sensors Inductive Sensors Inductive Proximity Sensors are used when the target or object to be sensed is metal. Inductive types are the most widely used proximity sensors for industrial applications.
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.
More informationTongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.
1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.
More informationHIGH DENSITY TERMINAL BLOCKS
CONTROL LOGIC HIGH DENSITY TERMINAL BLOCKS c3controls new line of High Density terminal blocks are both innovative and user-friendly. Available in multiple terminal points from 4, 6, and 12 in a single
More information4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current
Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4
More informationMachine Safety. Products
January 23 Vol. 2, Ref. No. [1263] -1 Machine Safety Products Contents Description Page............................................. -2 Key Interlock Switches DIN Models.............................. -9
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationD2600 Relay. 1. Relay Types. 2. Technical Data
C & S Controls Ltd. Upland Road, Bexleyheath, Kent, DA7 NR. Tel: Fax: Email: Web: + (0)08 30 88 + (0)08 30 938 sales@candscontrolsltd.com www.candscontrolsltd.com D00 Relay High integrity plug-in relays
More informationSECTION ELECTRICAL CONTROL DEVICES
ELECTRICAL CONTROL DEVICES PART 1 GENERAL 01 02 03 04 05 SCOPE The Contractor shall furnish and install, where indicated on the drawings, equipment with electrical control devices installed as specified
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationControls Enclosed Non-Combination Starters - PESW Series
NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower
More informationPush Buttons and Operator Interface New Product Catalog XAL Control Stations
Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationAC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:
Minarik Variable Speed AC Motor Drives AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY INSTALLATION INSTRUCTIONS Document Number: 250-0297 These instructions apply to models rated: 7.5 25
More informationPLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description
PLC-R 2HC PLC INERFCE With SPD Relay, High-Current Version INERFCE Data Sheet 022_03_en PHOENIX CONC - 02/08 Description number of applications such as electrical heating systems require higher continuous
More informationMagnetic Style Safety Interlock Switches
Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationWith operation indicators **LY2N-CR **LY2ZN-CR
Bi-power Relays LY E Power-switching Compact General-purpose Relays The standard models include models that are compliant with the UL, CSA, and SEV safety standards and with the Electrical Appliances and
More information